Loading...
HomeMy WebLinkAbout23-5521C I fy—o- t e p 5335 Eighth Street Zephyrhills, FIL 33542 Phone: (813) 780-0020 Fax: (813) 780-0021 ELCMISC-005521. 023 Issue Date: 01113/2023 REINSPECTION FEES: (c) With respect to Reinspection fees will comply with Florida Statute 553.80(2)(c) the local government shall impose a fee of four times the amount of the fee imposed for the initial inspection or first reinspection, whichever Is greater, for each subsequent reinspection. Notice: In addition to the requirements of this permit, there may be additional restrictions applicable to this property that may be found in the public records of this county, and there may be additional permit required from other governmental entities such as water management, state agencies or federal agencies. -'Warning to owner: Your failure to record a notice of commencement may result in your paying twice for mln=r = =M III 11 0 accordance with City Codes and Ordinances. N6'OCCUPANCY BEFORE C.O. NO OCCUPANCY BEFORE C.O. 1A -g"CONTRACTOR SIGNATURE PE?AIT OFFICEt) PERMIT EXPIRES IN 6 MONTHS WITHOUT APPROVED INSPECTION 0 HEM 813-780-0020 City of Zephyrhills Permit Application Fax-e13-780-0021 Building Department 813 64008 ,; 1�i; JK,MIR�#li'. k! W"1� i?�>+ } -iR #�71. !! ■.iF s"!I'. FW��,�Mp'll =61=731IMM72 RIM iF � R • .. - � �' ilw yl (OBTAINED FRO. PROPERTY WORK PROPOSED NEWCONSTRF� IALT SIGN DEMOLISH :: INSTALLREPAIR PROPOSED USE SFR COMM OTHER . OF., CONSTRUCTION A,. ,i E: FRAME BLOCK DESCRIPTION OF WORK Installation of a roof -mounted photovoltaic solar panel system. BUILDING i !1 FOOTAGE HEIGHT C-5UILDING LL= VALUATION OF TOTAL CONSTRUCTION ELECTRICAL $ AMP SERVICE PROGRESS ENERGY = W.R.E.C. PLUMBING $ MECHANICAL $ VALUATION OF MECHANICAL INSTALLATION GAS ROOFING ® SPECIALTY = OTHER FINISHED FLOOR O M ZONE AREA Sunrun Installation Services, Inc. K !' ... • n Services, Inc, RESIDENTIAL Attach (2) Plot Plans; (2) sets of Building Plans; (1) set of Energy Forms; it]6w4i�mii for new construction, Minimurn ten (10) working days after submittal date. Required onslite, Construction Plans, Stormwater Plans w/ Sift Fence installed, SaNtary, Facilities & I clumpster, Site Work Permit for di projects COMMERCIALcomplete sets ofBuilding Plansof EnOW Forms.Permit for •.. Minimum ten l i days after. ..a. Requirod onsite, Construction Plans, to Plans installed, Sanitary Facilities & I dumpster. Site Woek Permito all new projects, All commercial requirements , _ compliance SIGN PERMIT Attach (2) sets of -PROPERTY Fill out o ♦ x:Y to completely.. back application, If over i , a Notice of Commencement Is required, (AIC upgrades over $7500) "° Agent (for the contractor) or Power of Attorney (for the owner) would be someone with notarized letter from owner authorizing same OVER THE COUNTER PERMITTING (copy of contract required) Reroofs if shingles Sewers Service Upgrades AfC Fences(PlottSurvey/Footage) DrNre -Not over Counter if on public roadways.,needs ROW 813-M-0020 City of Ztephyrhills Permit Application Fax-813-780-M21 Sul ding Department NOTICE OF DEED RESTRICTIONS: The undersigned understands that this permit maybe subject to"deed"restrictions" which maybe more restrictive than County regulations, The undersigned assumes responsibility for compliance with any applicable deed restrictions. UNLICENSED CONTRACTORS AND CONTRACTOR RESPONSIBILITIES: 0 the owner has hired a contractor or contractors to undertake work, they may be required to tie licensed in accordance with state and local regulations. It the contractor Is not licensed as required by law, both the owner and contractor may be cited for a misdemeanor violation under state taw. If the owner or Intended contractor are uncertain as to what licensing requirements may apply for the intended work, they are advised to contact the Pasco County Building Inspection Division- Licensing Section at 727-847- MM Furthermore, if the owner has hired a contractor or contractors, he Is advised to have the contractor(s) sign portions of the "contractor Block" of this application for which they will be responsible. If you, as the owner sign as the contractor, that may be an Indication that he is not properly licensed and is not entitled to permitting privileges in Pasco County, TRANSPORTATION IMPACT/UTILITIES IMPACT AND RESOURCE RECOVERY FEES: The undersigned understands that Transportation Impact Fees and Recourse Recovery Fees may apply to the construction of new buildings, change of use in existing buildings, or expansion of existing buildings, as specified In Pasco County Ordinance number 89-07 and 90-07, as amended, The undersigned also understands, that such fees, as may be due, will be Identified at the time of permitting. It is further understood that Transportation Impact Fees and Resource Recovery Fees must be paid prior to receiving a 'certificate of occupancy" or final power release, If the project does not involve a certificate of occupancy or final power release, the fees must be paid prior to permit Issuance. Furthermore, if Pasco County Water/Sewer Impact fees are due, they must be paid prior to permit issuance In accordance with applicable Pasco County ordinances. CONSTRUCTION LIEN LAW (Chapter 713, Florida Statutes, as amended): 11 valuation of work is $2,500.00 or more, I certify that 1, the applicant, have been provided with a copy of the "Florida Construction Lien Law--Horraownees Protection Guide' prepared by the Florida Department of Agriculture and Consumer Affairs. If the applicant is someone other than the 'owner", I certify that I have obtained a copy of the above described document and promise in good faith to deliver it to the "owner' prior to commencement. CONTRACTOR'SIOWNERIS AFFIDAVIT: I certify that all the Information in this application is accurate and that all work will be done in compliance with all applicable to" regulating construction, zoning and land development. Application is hereby made to obtain a permit to do work and installation as indicated. I certify that no work or installation has commenced prior to issuance of a permit and that all work will be performed to meet standards of all laws regulating construction, County and City codes, zoning regulations, and land development regulations In the jurisdiction. I also certify that I understand that the regulations of other government agencies may apply to the intended work, and that it Is my responsibility to identify what actions I must take to be in compliance, Such agencies include but are not limited to: Department of Environmental Protection -Cypress Bayheads, Wetland Areas and Environmentally Sensitive Lands, Water/Wastewater Treatment. Southwest Florida Water Management District -Wells, Cypress Bayheads, Weiland Areas, Altering Watercourses. Army Corps of Engineers -Seawalls, Docks, Navigable Waterways. Department of Health & Rehabilitative Services/Environmental Health Unit -Wells, Wastewater Treatment, Septic Tanks. US Environmental Protection Agency -Asbestos abatement. Federal Aviation Authority -Runways, I understand that the following restrictions apply to the use of fill: - Use of fill is not allowed in Flood Zone "V" unless expressly permitted. - If the fill material is to be used in Flood Zone 'A", it is understood that a drainage plan addressing a "compensating volume" will be submitted at time of permitting which is prepared by a professional engineer licensed by the State of Florida. - If the fill material is to be used in Flood Zone "A" in connection with a permitted building using stem wall construction, I certify that fill will be used only to fill the area within the stem wall. - If fill material is to be used in any area, I certify that use of such fill will not adversely affect adjacent properties. If use of fill is found to adversely affect adjacent properties, the owner may be cited for violating the conditions of the building permit issued under the attached permit application, for lots less than one (1) acre which are elevated by fill, an engineered drainage plan is required. If arnthe AGENT FOR THE OWNER, I promise in good faith to inform the owner of the permitting conditions set forth inthis affidavit prior to, commenting construction. I understand that a separate permit may be required for electrical work, plumbing, signs, wells, pools, air conditioning, gas, or other installations not specifically included in the application, A permit issued shall be construed to be a license to proceed with the work and not as authority to violate, cancel, alter, or set aside any provisions of the technical codes, nor shall issuance of a permit prevent the Building Official from thereafter requiting a correction of anent in plans, construction or violations of any codes. Every permit Issued shall become invalid unless the work authorized by such permit is commenced within six months of permit issuance, or if work authorized by the permit is suspended or abandoned for a period of six (6) months after the time the we* is commenced. An extension may be requested, in writing, from the Building Official for a period not to exceed ninety (90) days and Wit demonstrate justifiable cause for the extension. If work ceases for ninety (90) consecutive days, the job is considered abandoned. OWNER OR A( Subscribed and TIM 0171 1__�AI II I t__::__:�_#_Notary Public ornmission No. IZI�qo i i���i1 I 11ilmiggagualliat #1W ASHLEIGH K JANSS.., Notary Public State Of Florida colnmissronP , 1,41`1 131990 mycorrunissionExpires: 5/21 2025 K I ASHLEIGH M, JANSS, Notary Public, State Of F i a A Nor li" 13 0 My Commission Expli 51 P 025 71111014111IT0 OF WORK GENERAL NOTESSCOPE T TABLE OF CONTENTS PAGE # DESCRIPTION • SYSTEM SIZE: 480OW DC, 380OW AC • ALL WORK SHALL COMPLY WITH 2O20 FBC (7TH ED.) AMENDMENTS TO 2018 -- SOLAR MODULES e -1.0 PV COVER SHEET • MODULES: (12) HANWHA Q-CELLS: Q.PEAK DUO BLK IRC/IBC/IEBC, MUNICIPAL CODE, AND ALL MANUFACTURERS' LISTINGS AND SE SERVICE ENTRANCE _ ML-G10+ 400 INSTALLATION INSTRUCTIONS. —e PV-2.0 SITE PLAN • INVERTERS: (1) SOLAREDGE TECHNOLOGIES: • PHOTOVOLTAIC SYSTEM WILL COMPLY WITH NEC 2017. SE380OH-USMN F MAIN PANEL PV-3.0 LAYOUT RACKING: RL UNIVERSAL, SPEEDSEAL TRACK ON COMP, • ELECTRICAL SYSTEM GROUNDING WILL COMPLY WITH NEC 2017. PV-4.0 ELECTRICAL SEE DETAIL SNR-DC-00436 • PHOTOVOLTAIC SYSTEM IS UNGROUNDED. NO CONDUCTORS ARE SOLIDLY �SP __tea_. SUB -PANEL SNR MOUNT PV-5.0 SIGNAGE SNR MOUNT &SKIRT GROUNDED IN THE INVERTER. SYSTEM COMPLIES WITH 690.35. • MODULES CONFORM TO AND ARE LISTED UNDER UL 1703. LC PV LOAD CENTER sr,._,j CHIMNEY • INVERTER CONFORMS TO AND IS LISTED UNDER UL 1741. F-1S SUNRUN METER • RACKING CONFORMS TO AND IS LISTED UNDER UL 2703. ATTIC VENT • SNAPNRACK RACKING SYSTEMS, IN COMBINATION WITH TYPE 1, OR TYPE 11 R DEDICATED PV METER L__ J FLUSH ATTIC VENT MODULES, ARE CLASS A FIRE RATED. 0 PVC PIPE VENT • RAPID SHUTDOWN REQUIREMENTS MET WHEN INVERTERS AND ALL INV INVERTER(S) '0 METAL PIPE VENT CONDUCTORS ARE WITHIN ARRAY BOUNDARIES PER NEC 690.12(1). M. T-VENT F—AC-1 • CONSTRUCTION FOREMAN TO PLACE CONDUIT RUN PER 690.31(G). IEEII AC DISCONNECT(S) fi � SATELLITE DISH • ARRAY DC CONDUCTORS ARE SIZED FOR DERATED CURRENT. _ DC DC DISCONNECT(S) FIRE SETBACKS • 11.14 AMPS MODULE SHORT CIRCUIT CURRENT. • 17.4 AMPS DERATED SHORT CIRCUIT CURRENT [690.8 (A) & 690.8 (B)j. CB IQ COMBINER BOX 1 HARDSCAPE i- —I INTERIOR EQUIPMENT — PL— PROPERTY LINE Le -1 SHOWN AS DASHED SCALE: NTS A AMPERE sunrun AC ALTERNATING CURRENT AFCI AZIM ARC FAULT CIRCUIT INTERRUPTER AZIMUTH ENGINEER225BUSH SDT, SUITE 1400 P, 949383-0 93Q CA 94104 VICINITY MAP COMP COMPOSITION DC DIRECT CURRENT EC13007964 (E) EXISTING 5208 TAMPA 3N BLVD, TAMPA., FL 33634 ESS EXT ENERGY STORAGE SYSTEM EXTERIOR PHONE 0 FAX 0 INT INTERIOR CUSTOMER RESIDENCE: MAG MAGNETIC THAO NGO MSP MAIN SERVICE PANEL 35821 IRON REDDING CT, (N) NEW ZEPHYRHILLS, FL, 33541 p8 NTS NOT TO SCALE OC ON CENTER TEN. (813)-08 #35821 1tc1n iT _ 8 No, 85111 B PRE-FAB PSF PRE -FABRICATED POUNDS PER SQUARE FOOT APN: 32-25-2121-0040-01300-0120 C1, Zephydiills, FI _. _ ; $ _ a : - PROJECT NUMBER: ,4 STATE OF PV PHOTOVOLTAIC 802R-821 NGO RSD RAPID SHUTDOWN DEVICE PO'�N�c TL TRANSFORMERLESS DESIGNER: (415) 580-6920 ex3 TYP TYPICAL nr,erciERICKA rrf �`,� V VOLTS JEAN AMPELOQUIO EXPIRES: 2/28/2023 W WATTS SIGNED:11/16/2022 SHEET REV NAME DATE COMMENTS COOLER SHEET REV: A 11/16/2022 rats>agg Q�v< PAGE PV-1.0 ARRAY TRUE MAG PV AREA SITE PLAN - SCALE = 1/16" = V-0 PITCH AZIM AZIM (SQFT) AR-01 23' 125' 134' 253.6 PL ev PL e" (E) RESIDENCE e sun fAmun e" ek t' yy, ev (N) ARRAY AR-01 ENGINEER ADDRESS: (E) DRIVEWAY e� SANSFRANCISCo SUITE P: 949-383-0993 EC13007964 5208 TAMPA W SLVD, TAMPA, FL 33634 PHONE 0 ... Q� FAX 0 I_SP CUSTOMER RESIDENCE: ev THAO NGO 35821 IRON BEDDING CT, ZEPHYRHILLS, FL, 33541 e SE AC iNV TEL (813) 382-9058 APN:32-25-21-0040-01300-0120 b PROJECT NUMBER: r '• STATE OF � L � �. � 802R-821 NGO �Oitt3' DESIGNER: (415) 580-6920 ex3 <?A pofN PL ERICKA JEAN AMPELOQUIO ///I t 1111\11 C CT SHEET 1 /11 /2023 SITE PLAN REV: A 11/16/2022 PAGE P-2.0 ROOF INFO FRAMING INFO ATTACHMENT INFORMATION DESIGN CRITERI Name Type Height Type Max OC Detail Max Landscape Max Landscape Max Portrait Max Portrait Configuration MAX DISTRIBUTED LOAD: Span Spacing OC Spacing Overhang OC Spacing Overhang SNOW LOAD: 0 PSF RL UNIVERSAL, SPEEDSEAL TRACK ON WIND SPEED: S.S. LAG SCREW a 5116"x4.5": 2.5" MIN. EMBEDMENT STRUCTURAL NOTES * INSTALLERS SHALL NOTIFY ENGINEER OF ANY POTENTIALSTRUCTURAL ISSUES OBSERVED PRIOR TO PROCEEDING * IF ARRAY (EXCLUDING SKIRT) IS WITHIN 12" BOUNDARY REGION OF ANY ROOF PLANE EDGES (EXCEPT VALLEYS), THEN ATTACHMENTS NEED TO BE ADDED AND OVERHANG REDUCED WITHIN THE 12" BOUNDARY REGION ONLY AS ** ALLOWABLE ATTACHMENT TO BE REDUCED BY 50%. ** ALLOWABLE OVERHANG INDICATED ON PLANS TO BE 1/5TH OF ALLOWABLE ATTACHMENT SPACING INDICATED ON PLkIJS. ENGINEER ADDRESS: zoBUSH ST, SUITEww wwrRAwCIoCO,o^94,04 ,.94v'w3omm EC13DO7S54 5208 TAMPAwBLVD'rAMPA, FL 33634 roowEo FAX CUSTOMER RESIDENCE: THA0NGO 35O21IRON REDD|M{)CT, ZEPHYRH|LLS.FL, 33541 TEL (813)382-9055 APN:32'25-21-0040-01300-0120 PROJECT NUMBER: 802R-821NG0 DESIGNER: (415)500-6820ox3 ER)CKAJEAN AMPELOQU|O SHEET LAYOUT REy:A 11/18/2022 PAGE FdVaj#M-dmqfrfjjr4rm METER #: DUKE ENERGY 8160489 EXISTING 200A MAIN BREAKER t (END FED) ----- EXISTING 200A MAIN PANEL EXISTING —� 225A SUB :— PANEL LITY GROUND (N) 20A PV BREAKER AT OPPOSITE END OFBUSBAR EaOCKABLE*fir CONDUIT SCHEDULE # CONDUIT CONDUCTOR NEUTRAL GROUND 1 NONE (2) 10 AWG PV WIRE NONE (1) 6 AWG BARE COPPER 2 3/4" EMT OR EQUIV. (2) 10 AWG THHN/THWN-2 NONE (1) 8 AWG THHN/THWN-2 3 3/4" EMT OR EQUIV. (2) 10 AWG THHN/THWN-2 (1) 10 AWG THHN/THWN-2 (1) 8 AWG THHN/THWN-2 E EXISTING EXISTING EXISTING EXISTING MODULE CHARACTERISTICS P401 OPTIMIZER CHARACTERISTICS: DUO B •00 W VDC sr RCU'ITVOLTAGE.• MAX INPUT ISC: 11.75 ADC MAX POWER VOLTAGE: 37,13 V MAX OUTPUT CURRENT: 15 ADC SHORT CIRCUIT CURRENT: 11.14 A SYSTEM SIZE: 4800 SYSTEM OPENCIRCUIT VOLTAGE: SYSTEM OPERATING VOLTAGE: MAX ALLOWABLE DC VOLTAGE: 480 V SYSTEM OPERATING 12.63 t SHORTSYSTEM CIRCUIT CURRENT: SOLAREDGE TECHNOLOGIES: SE380OH-USMN 3800 WATT INVERTER ,2 LOAD RATED DC DISCONNECT WITH AFCI, RAPID SHUTDOWN COMPLIANT JUNCTION BOX PV MODULES OR EQUIVALENT 1 HANWHA Q-CELLS: Q.PEAK DUO BLK M L-G 10+ 400 (12) MODULES OPTIMIZERS WIRED IN: (1) SERIES OF (12) OPTIMIZERS SOLAREDGE POWER OPTIMIZERS • f \,�}i1111111111j1JJ _ s No. 85111 +ba 8 8 STATE OF ! _ EXPIRES: 2/28/2023 SIGNED: 11/16/2022 SIDES. 1 THE OPEN POSITION LABEL LOCATION: INVERTER(S), AC/DC DISCONNECT(S), AC COMBINER PANEL (IF APPLICABLE). PER CODE(S): CEC 2019: 690.13(B), NEC 2017: 690.13(B) —2 ill �TO 46• 011 io� LABEL LOCATION: ADJACENT TO PV BREAKER (IF APPLICABLE). PER CODE(S): CEC 2019: 705.12(13)(2)(3)(b), NEC 2017: 705.12(B)(2)(3)(b) LABEL LOCATION: PHOTOVOLTAIC AC COMBINER (IF APPLICABLE), PER CODE(S): CEC 2019: 705.12(B)(2)(3)(c), NEC 2017: 705.12(13)(2)(3)(c) DUAL POWER ■ UTILITY ■III II ■* ■ i AND SOLAR ELECTRIC SYSTE114 LABEL LOCATION: UTILITY SERVICE METER AND MAIN SERVICE PANEL. PER CODE(S): CEC 2019: 705.12(B)(3), NEC 2017: 705.12(B)(3) LABEL LOCATION: INTERIOR AND EXTERIOR DC CONDUIT EVERY 10 FT, AT EACH TURN, ABOVE AND BELOW PENETRATIONS, ON EVERY JB/PULL BOX CONTAINING DC CIRCUITS. PER CODE(S): CEC 2019: 690.31(G)(3), 690.31(G)(4), NEC 2017: 690.31(G)(3), 690.31(G)(4) IFC 2012: 605.11.1.4 LABEL LOCATION: AC DISCONNECT(S), PHOTOVOLTAIC SYSTEM POINT OF INTERCONNECTION. PER CODE(S): CEC 2019: 690.54, NEC 2017: 690.54 3„ LABEL LOCATION: INVERTER(S), DC DISCONNECT(S). PER CODE(S): CEC 2019: 690.53, NEC 2017: 690.53 LABEL LOCATION: INSTALLED WITHIN S OF RAPID SHUT DOWN SWITCH PER CODE(S): CEC 2019: 690.56(C)(3), NEC 2017: 690.56(C)(3), IFC 2012: 605,11.1, IFC 2018: 1204.5.3, CFC 2019: 1204.5.3 4„ SWITCH TO THE • ■ ■ SHOCK' ■ IN THE LABEL LOCATION: ON OR NO MORE THAT 1 M (3 FT) FROM THE SERVICE DISCONNECTING MEANS TO WHICH THE PV SYSTEMS ARE CONNECTED. PER CODE(S): CEC 2019: 690.56(C)(1)(a), NEC 2017: 690.56(C)(1)(a) NOTES AND SPECIFICATIONS. • SIGNS AND LABELS SHALL MEET THE REQUIREMENTS OF THE NEC 2017 ARTICLE 110.21(B), UNLESS SPECIFIC INSTRUCTIONS ARE REQUIRED BY SECTION 690, OR IF REQUESTED BY THE LOCAL AHJ. • SIGNS AND LABELS SHALL ADEQUATELY WARN OF HAZARDS USING EFFECTIVE WORDS, COLORS AND SYMBOLS. • LABELS SHALL BE PERMANENTLY AFFIXED TO THE EQUIPMENT OR WIRING METHOD AND SHALL NOT BE HAND WRITTEN. • LABEL SHALL BE OF SUFFICIENT DURABILITY TO WITHSTAND THE ENVIRONMENT INVOLVED. • SIGNS AND LABELS SHALL COMPLY WITH ANSI Z535.4-2011, PRODUCT SAFETY SIGNS AND LABELS, UNLESS OTHERWISE SPECIFIED. • DO NOT COVER EXISTING MANUFACTURER LABELS. *etttttti1111! H /!�� a No. 85111 a _ 8 8 8 8 STATE OF j 11 % 8w. OR�d�\� EXPIRES: 2/28/2023 SIGNED: 11/16/2022 Astra v. 1 � 761 January 11, 2023 sunr U n WS CAT 1 Subject : Structural Certification for Proposed Residential Solar Installation. James Matthew Walsh. State of Florida, Professional Engineer, License No, 84923 Job Number: 802R-821 NGO; Rev A tp Client: Thao Ngo 23 N1' ':5' This item has been digitally signed and sealed o� Address: 35821 Iron Redding Ct, Zephymills, FL, 33541 A' �by James Matthew Walsh, PE on 1/11/2023 using a Digital Signature. Printed copies of this or. (41ATE OF 0 --71,men i� 5 t are not considered signed and sealec t T 441 -Z, and the SHA authentication code must be e. 4F Attn: To Whom It May Concern it , ORIverified on electronic copies, V /ONAL oInjukkol", / A field observation of the existing structure at the address indicated above was performed by a site survey team from Sunrun. Structural evaluation of the loading was based on the site observations and the design criteria listed below. Design Criteria: • 2020 FBC (7th Ed.) AMENDMENTS TO 2018 IRC/IBC/IEBC, 7-16 ASCE & 2018 NDS Basic Wind Speed V = 138 mph, Exposure B - Ground Snow Load = 0 psf Based on this evaluation, I certify that the alteration to the existing structure by the installation of the PV system meets the requirements of the applicable existing and/or new building code provisions referenced above. Additionally, I certify that the PV module assembly including all attachments supporting it have been reviewed to be in accordance with the manufacturer's specifications, 225 Bush St. Suite 1400 San Francisco, CA 94104