HomeMy WebLinkAbout23-5629Mit—y—of -Zephyr h i 119 5335 Eighth Street Zephyrhills, FL 33542 Phone: (813) 780-0020 Fax: (813) 780-0021 BAR-005629-2023 sj Issue Date: 02/24/2023 REINSPECTION FEES: (c) With respect to Reinspection fees will comply with Florida Statute 553.80(2)(c) the local government shall impose a fee of four times the amount of the fee imposed for the initial inspection or first reinspection, whichever is greater, for each subsequent reinspection. Notice: In addition to the requirements of this permit, there may be additional restrictions applicable to this property that may be found in the public records of this county, and there may be additional permit required from other governmental entities such as water management, state agencies or federal agencies, j[55��I 11111 11111�1111111 , 11111111p I III 111 11 . I EWA= Complete Plans, Specifications add fee Must Accompany Application. All work shall be performed ir accordance with City Codes and Ordinances. NO OCCUPANCY BEFORE C.O. NO OCCUPANCY BEFORE C.O. CONTRACTORSIGNATURE -AqOFF14 PE IT CE PERMIT EXPIRES IN 6 MONTHS WITHOUT APPROVED INSPECTION CALL FOR INSPECTION - 8 HOUR NOTICE REQUIRED PROTECT C1RD FROM WEATHER ("4K APPLICATION FOR APPROVAL EXTERNAL ARCHITECTURAL OR LANDSCAPING *1! ?EMM From: OWNER: LOT # ADDRESS REQUEST FOR: I/ Preliminary Approval? Final Approval? 1, the undersigned owner, hereby request approval of the following described external architectural or landscape improvement, alteration, addition, deletion or repair as required by the governing documents: -A- Ortv'l I r- -�- 1� I i '�; ( (� Cs ip c, r>a-o pr.-� f) r7 rgg Fo m T- i 6',1 Plans are attached: Yes No Estimate Date of Completion: '2 Note: Plans are REQUIRED for all requests detailing any and all changes proposed. Plans need to provide 1p. I rip ira t a 6 Owners Signature: W�: Approval valid until this date: ZMEMM Date: Date: Date: �—Z— 813-780-0020 City of Zephyrhills Permit Application Fax-813-780-0021 Building Department N 57T.Trju�� Owner Phone Number "1 00, A on MOLM-1 W SUBDIVISION IV/XLtd C11 /1140 0 e c44 S I PARCEL ID# 60JQ_- 066bb yr (OBTAINED FROM PROPERTY TAX NOTICE) WORK PROPOSED NEW CONSTRF--1 El ADD/ALT SIGN DEMOLISH I INSTALL F-1 (RE P A PROPOSED USE SFR 0 COMM OTHER TYPE OF CONSTRUCTION BLOCK C:3 FRAME STEEL DESCRIPTION OF -WORK BUILDING SIZE [73�11UILDING VALUATION OF TOTAL CONSTRUCTION =ELECTRICAL I7-1 AMP SERVICE PROGRESS ENERGY W.R.E.C. =PLUMBING L =MECHANICAL VALUATION OF MECHANICAL INSTALLATION JW =GAS ROOFING SPECIALTY OTHER Jld FINISHED FLOOR ELEVATIONS FLOOD ZONE AREA =YES NO BUILDER COMPANY CIA($ SIGNATURE REGISTERED Y/ N FEE CURREK Y/N License# 3/d, Address ELECTRICICOMPY AN ANE REGISTERED ;;;;FEE C�URREII SIGNATURE License Address PLUMBER COMPANY E SIGNATURE REGISTERED ;;;;FEE C�URREII Address License MECHANICAL COMPANY ;� FEE CURREN���� SIGNATURE REGISTERED License #E____=== Address r- OTHER COMPANY L==FEE C`uRRENE=____J SIGNATURE REGISTERED Address License RESIDENTIAL Attach (2) Plot Plans; (2) sets of Building Plans; (1) set of Energy Forms; R-O.W Permit for new construction, Minimum ten (10) working days after submittal date. Required onsite, Construction Plane, Stormwator Plains wl Sift Fence Installed, Sanitary Facilities & I dumpster; Site Work, Permit for subdivisions/large projects COMMERCIAL Attach (2) complete sets of Building Plans plus a Life safety Page; (1) set of Energy Forms, R-O-W Permit for now. construction. Minimum ten (10) working days after submittal date. Required onsite, Construction Plans, Stormwater Plans wl $01: Fence installed, Sanitary Facilities & 1 dumpster, Site Work Permit for all new projects. All commercial requirements must meet compliance SIGN PERMIT Attach (2) sets of Engineered Plans. ****PROPERTY SURVEY required for all NEW construction. Directions: Fill out application completely. Owner & Contractor sign back of application, notarized if over $2500, a Notice of Commencement Is required. (AIC upgrades over $7500) .. Agent (for the contractor) or Power of Attorney (for the owner) would be someone with notarized letter from owner authorizing same OVER THE COUNTER PERMITTING (copy of contract required) Reroofs if shingles Sewers Service Upgrades A/C I Fences (Plot/Survey/Footage) Driveways -Not over Counter if on public roadways..needs ROW General Notes A. CONCRETE & FOUNDATION DESIGN: I. ALL CONCRETE GRADE BEAMS AND FOOTINGS SHALL BE 3000 PSI MINIMUM. 2. ALL CONCRETE FILLED SUPPORTED SLABS SHALL BE 2500 PSI MINIMUM, 3 1/2" NOMINAL THICKNESS. 3. 3000 PSI FIBERMESH (33/4" PER CUBIC YARD MIN.) MEETING APPROPRIATE ACI AND ASTM REQUIREMENTS MAY BE USED IN LIEU OF WELDED WIRE MESH 4. ALL SLABS ON GRADE SHALL BE 4" THICK WITH FIBERI'TESH, TERMITE TREA TMENT OF SOIL BENEATH SLAB IS NOT REQUIRED IF SLAB DOES NOT ABUT A WOOD FRAME STRUCTURE. NO WOOD FRAME STRUCTURE MAY BE BUILT ADJACENT TO OR ON TOP OF A SLAB WITHOUT TREATING THE SOIL FOR WOOD DESTROYING ORGANISMS. 5. ALL REINFORCING SHALL CONFORM TO ASTM A615, BE GRADE 60 (60 KSI MIN.) DEFORMED BARS, #3 BARS MAY BE GRADE 40 6. ALL OVER POUR CONCRETE FILLED SUPPORTED SLABS SHALL BE 3000 PSI MIN,, 2" MINIMUM. THICKNESS. 7, SOIL BEARING PRESSURE SHALL BE A MINIMUM OF 1500 PSF. 8. THE CONCRETE SHALL CONFORM TO ASTM C94 FOR THE FOLLOWING: OPC (PORTLAND CEMENT TYPE I, ASTM C 150). AGGREGATES - #6 STONE, ASTM C 33 SIZE NO. 67 LESS THAN 3/4". AIR ENTRAINING +/- 1% - ASTM C 260, WATER REDUCING AGENT - ASTM C 494. CLEAN, POTABLE WATER. OTHER ADMIXTURES SHALL NOT BE PERMITTED. 9. METAL WELDED WIRE SHALL CONFORM TO ASTM A 185. 10- PREPARE & PLACE CONCRETE ACCORDING TO AMERICAN CONCRETE INSTITUTE MANUAL STANDARD PRACTICE, PART 1, 2. & 3 ALONG WITH HOT WEATHER CONDITIONS RECOMMENDATIONS. 11. IF UTILIZING EXISTING CONCRETE FOR FOUNDATION, CONCRETE SHALL BE A MINIMUM OF 4" IN THICKNESS, VISIBLY FREE OF ANY STRUCTURAL EXCESSIVE CRACKING, SPALLING OR OTHER DETERIORATION. B. MASONRY: i. CONCRETE MASONRY UNITS (CMU) SHALL BE STANDARD HOLLOW UNITS AND SHALL BE 1900 PSI MINIMUM BASED ON TYPE M OR S MORTAR- 2.ALL MORTAR SHALL BE OF TYPE M OR S. 3.ALL GROUT SHALL BE 2000 PSI MINIMUM AND HAVE MAXIMUM COARSE AGGREGATE SIZE OF 3/8". 4-PROVIDE CLEAN -OUTS FOR REINFORCED CELLS CONTAINING REINFORCEMENT WHEN GROUT POUR EXCEEDS T-0" IN HEIGHT. C. ALUMINUM: I. ALL STRUCTURAL ALUMINUM SHALL CONFORM TO THE MINIMUM REQUIREMENTS OF 6005-T5 FOR ALLOY WITH A MINIMUM THICKNESS OF 0.040" FOR SUPPORTING MEMBERS. 2. WHERE KICK PLATES ARE USED A MINIMUM THICKNESS OF 0.024" SHALL APPLY. 3. STRUCTURAL ALUMINUM DESIGN CONFORMS TO "PART I -A - SPECIFICATIONS FOR ALUMINUM STRUCTURES - ALLOWABLE STRESS DESIGN" OR "PART I-B - SPECIFICATIONS FOR ALUMINUM STRUCTURES - BUILDING LOAD AND RESISTANCE FACTOR DESIGN" OF THE CURRENT ALUMINUM DESIGN MANUAL PREPARED BY THE ALUMINUM ASSOCIATION, INC.WASHINGTON D.C. THE FLORIDA BUILDING CODE, 7TH EDITION (CHAPTER 16 STRUCTURAL DESIGN & CHAPTER 20 ALUMINUM). 4. WHERE ALUMINUM COMES INTO CONTACT WITH STEEL, OR PRESSURE TREATED LUMBER PROVIDE DIELECTRIC SEPARATION. 5. ALUMINUM MEMBERS SHALL BE STITCHED WITH NO LESS THAN #10 SMS 6" FROM THE ENDS AND 12" ON CENTER, IF USING #12 SPACING MAY BE 24" ON CENTER. 6. VINYL AND ACRYLIC PANELS SHALL BE REMOVABLE. THEY SHALL BE IDENTIFIED WITH A DECAL ESSENTIALLY STATING "REMOVABLE PANEL SHALL BE REMOVED WHEN WIND SPEEDS EXCEED 75 MPH". DECAL SHALL BE PLACED SO IT IS VISIBLE WHEN PANEL IS IN TALLED. D.FASTENERS: i. ALL LAG BOLTS SHALL CONFORM TO STAINLESS STEEL TYPE 300 18-8, WITH STANDARD FLAT WASHER UNLESS MANUFACTURER GALVANIZES BOLTS SPECIFIES FOR USE WITH ACQ PRESSURE TREATED WOOD. 2. HEX BOLTS HAS TO BE ASTM A 325, PLATED WITH STANDARD FLAT WASHERS AND NUTS. 3, ALL CONCRETE SCREWS SHALL BE, SIMPSON, HILTI, BAWL, TATCON, REDHEAD, DYNABOLT, OR APPROVED EQUAL. 4. ALL METAL TIES AND ASSOCIATED ACCESSORIES SHALL BE HOT DIPPED GALVANIZED. 5, ALL LAG BOLTS SHALL HAVE A MINIMUM EMBEDMENT OF BX BOLT DIAMETER INTO STRUCTURAL FRAMING (G=.42 MIN.). 6 LAG BOLTS AND SCREWS INTO WOOD FRAMING SHALL BE PROVIDED WITH PILOT HOLES HAVING A DIAMETER NOT GREATER THAN 70 PERCENT OF THE THREAD DIAMETER OF THE BOLT OR SCREW. ALL LAG BOLTS AND SCREWS SHALL BE INSERTED IN PILOT HOLES BY TURNING AND UNDER NO CIRCUMSTANCES BY DRIVING WITH A HAMMER. 7, ALL EXPANSION ANCHORS SHALL BE DESIGNED IN ACCORDANCE WITH THE SPECIFIC MANUFACTURER'S REQUIREMENTS AND ALLOWABLE LOADS AND SHALL ONLY BE APPLIED IN CONDITIONS ACCEPTABLE TO MANUFACTURER. FASTENERS SHALL BE A MINIMUM OF SAE GRADE #5 OR BETTER ZINC PLATED. 8. ALL FASTENERS CONNECTING ALUMINUM COMPONENTS OR PRESSURE TREATED LUMBER ARE STAINLESS STEEL TYPE 300 18-8, UNLESS MANUFACTURER GALVANIZED BOLTS SPECIFIES FOR USE WITH ACQ PRESSURE TREATED WOOD, OR OTHERWISE NOTED ON PLANS. 9. ALL FASTENERS SHALL COMPLY WITH ASTM A153. m ALL CONNECTORS SHALL COMPLY WITH ASTM A653 CLASS G-185. ii. FOR SMS, THE MINIMUM CENTER -TO -CENTER SPACING SHALL BE 3/4" AND MINIMUM CENTER -TO -EDGE SHALL BE 1/2" UNLESS NOTED OTHER WISE. E. REFERENCE STANDARDS: ASTM E 119 ASTM E1300 ASCE 7 -16 AA ASM35, AND SPEC. FOR ALUMINUM PART I -A, & I-B ASTM C94 ASTM C150 ASTM C33 ASTM C260 ASTM C494 ASTM A615 ASTM A185 FLORIDA BUILDING CODE (CHAPTERS 16,20 AND 23) 7TH EDITION CURRENT ALUMINUM DESIGN MANUAL F. ABBREVIATIONS: THE FOLLOWING LIST OF ABBREVIATIONS IS NOT INTENDED TO REPRESENT ALL THOSE USED ON THESE DRAWINGS, BUT TO SUPPLEMENT THE MORE COMMON ABBREVIATIONS. L TYR -- TYPICAL 2. SIM --SIMILAR 3. UON -- UNLESS OTHERWISE NOTED 4. CONT --CONTINUOUS S. VIE -- VERIFY IN FIELD G. RESPONSIBILITY: L ALL SITE WORK SHALL BE PERFORMED BY A LICENSED CONTRACTOR IN ACCORDANCE WITH APPLICABLE BUILDING CODES, LOCAL ORDINANCES, ETC. 2 CONTRACTOR SHALL VERIFY ALL DIMENSIONS AND DETAILS, NOTIFYING ENGINEER OF ANY DISCREPANCIES BETWEEN DRAWINGS, FABRICATED ITEMS, OR ACTUAL FIELD CONDITIONS. 3. THESE DRAWINGS REPRESENT THE ACCEPTABILITY OF THE 'SUNROOM'ROOM ADDITION ELEMENTS AS PROVIDED BY THE CONTRACTOR, 4. ALL DETAILS ON THESE DRAWINGS ARE ENGINEERED BASED ON INFORMATION PROVIDED BY THE CONTRACTOR AND MANUFACTURER. S. ANY DETAILS NOT SHOWN ARE TO BE ENGINEERED BY A LICENSED P.E. IN ACCORDANCE WITH STANDARD ENGINEERING PRACTICES, H. MISCELLANEOUS: 1. ALUMINUM ADDITIONS ARE NOT TO BE INSTALLED ON A MANUFACTURED HOME, TRAILER HOME, OR PRE-FAB HOME WITHOUT A MANUFACTURER'S HOST BEAM. IF NO HOST BEAM IS PRESENT A SEPARATE 4TH WALL SUPPORT SYSTEM SHALL BE ENGINEERED SO THAT NO ADDITIONAL LOADING IS PLACED ON THE MANUFACTURED HOME, 2. IF ENCLOSURE CONTAINS A SWIMMING POOL OR SPA, THE ENCLOSURE SHALL COMPLY WITH RESIDENTIAL SWIMMING BARRIER REQUIREMENTS OF THE REG 7TH EDITION R 45OL17.1 IN ITS ENTIRETY. 3. DOOR LOCATIONS MAY BE DETERMINED IN THE FIELD BY CONTRACTOR. 4. IF PAVERS ARE UNDER ALUMINUM MEMBERS THEY SHALL HAVE EPDXY ADHESIVE TO CONCRETE OR IF USING GROUT, ENSURE BONDING AGENT IS USED FIRST, 5. SCREENING MATERIAL SHALL BE I8X14X0.013 OR EQUIVALENT DENSITY SCREEN MESH ONLY UNLESS NOTED OTHERWISE. 6. EMERGENCY ESCAPE & RESCUE OPENING PER FBC R310.1 SHALL BE VERIFIED BY CONTRACTOR & BUILDING OFFICIAL 7. ENCLOSED ADDITIONS TO MANUFACTURED HOMES SHALL NOT CHANGE THE EXIT FACILITIES FOR EGRESS PER HUD 3280105, (@) THROUGH (a,(2)(iv), SO THAT THE DISTANCE TO EXIT DIRECTLY OUTSIDE FROM ALL BEDROOMS IS LESS THAN 35', AND, SO THAT TWO EXITS DIRECTLY OUTSIDE ARE STILL MAINTAINED. A CARPORT OR SCREEN ROOM SHALL BE CONSIDERED AS OUTSIDE, NON -HABITABLE SUNROOMS OR HABITABLE LIVING SPACE MAY BE ADDED WHERE AN EXIT DOOR WAS LOCATED AS LONG AS A NEW EXIT DOOR IS ADDED AND MEETS THE REQUIREMENTS OF HUD 3280.105. fi RIMFITIMA 1. ULTIMATE DESIGN WIND SPEED Vult, (3 SECOND GUST): 130MPH NOMINAL DESIGN WIND SPEED Vasd; 110 MPH 2, RISK CATEGORY: 1 3. WIND EXPOSURE: B 4. INTERNAL COEFFICIENT: CARPORT EXT, (OPEN STRUCTURE) +/- 0.00 5, WIND LOADS: FACTOR APPLIED TO WIND LOADS FOR ALLOWABLE STRESS DESIGN: 0.6 SOLID ROOF (MWFRS): 20 PSF COMPONENT & CLADDING PRESSURES: ROOF ZONE I: +12.4/-48,4PSF ROOF ZONE 2: +12.4/-619 PSF ROOF ZONE 3: +12.4/-87.1 PSF 6. EXISTING 4" CONCRETE SLAB, 2500 PSI CONCRETE W/ 6"X6'--#10WWM AND/OR 3000 PSI FIBERMESH AND FOOTER SHALL BE ADEQUATE TO RESIST THE UPLOADS FOR THE PROPOSED STRUCTURE 7. SOLID ROOF TYPE: 3'x12"x.024" ALUM. RISER PANS, FL 16952 OR EQUIV. EXISTING 3" RISER PANS low M9119INTA64 2 x 2: ---------------------------------------2" x 2" x 0.044" 3 x 2: ---------------------------------------3" x 2" x 0.050" 2 x 3: ---------------------------------------2" x 3" x 0.050" 2 x 3: ---------------------------------------2" x 3" x 0.070" 2 x 4: ---------------------------------------2" x 4" x 0.050" 2 x 5: ---------------------------------------2" x 5" x 0.050" 3 x 3: ---------------------------------------3" x 3" x 0.072", 3 x 3: ---------------------------------------3" x 3" x 0.093" 3 x 3: ---------------------------------------3" x 3" x 0.125" 4 x 4: ---------------------------------------4" x 4" x 0.125" OPEN BACK SECTIONS 1 x 2:---------------------------------------- I" x 2" x 0.040" 1 x 3: ----------------------------------------1" x 3" x 0,045" 2 x 2 Snap: ---------------------------------- 2" x 2" x 0.045" 2 x 3 Snap: ---------------------------------2" x 3" x 0,050" 2 x 4 Snap:--------------------------------- 2" x 4" x 0,045" NANIM��wx 2x4SMB: ---------------------- 2" x 4" x 0,044" x 0.100" 2x5SMB: ---------------------- 2" x 5" x 0.050" x 0.118" 2x6SMB ----------------------- 2" x 6" x 0.050" x 0.120" 2x7SMB ----------------------- 2" x 7" x 0,057" x 0.120" 2x8SMI3 ----------------------- 2" x 8" x 0.072" x 0.224" 2x9SMB ----------------------- 2" x 9" x 0.072" x 0.224" 2 x 10 SMB: ------------------- 2" x 10" x 0.092" x 0,374" WORK SHAU- cx,­,P.,A,o,,,v, ,,,1rrH P.F4%E',,!AA3UNG iass AL','"ELEC."TRIC' C'ODE, v THE Clr� OF ZEPH',, HILL, MANC'ES '04%1 L ILAJ -7 "Y C-f" Z EP'ri YR r UL INDEX S-1 GENERAL NOTES S-2 DRAWING PLANS & ELEVATIONS S-3 DETAILS - CARPORT EXTENSION S-4 DETAILS - CARPORT EXTENSION I HEREBY CERTI� REVIEWED THIS I iTa-16 AND T(ZC7TH EDIT) CD� RES1kDPNT4At*e NU� ExI STI N G BUILZ�[NG�- OFESS ////t11jjjjj tilt, ttt PROFESSIONAL ENGINEER SEAL David W. Smith P.E. FLORIDA LICENSE NUMBER: 53608 Thomas L. Hanson P.E. FLORIDA LICENSE NUMBER: 38654 Ian J. Foster P.E. FLORIDA LICENSE NUMBER: 93654 Joel Falardeau P.E. FLORIDA LICENSE NUMBER: 70667 Erik Stuart P.E. FLORIDA LICENSE NUMBER: 77605 FBC Plans & Engineering kervices, Inc. 5344 9th St Zephyrhills, fl. 33542 Phone: [813)838-0735 Website: wvrw.fbcp1ans.com C.O.A. - #29054 DATE: 02/04/2023 DRAWN BY: MARK DUNN SR. I REVISION: I DATE: I JOB# - 230116265 CREGG GRAND HORIZONS MHP 37604 NEW HORIZONS BLVD. ZEPHYRHILLS, FL 33541 SUNSTATE ALUMINUM ENGINEERS NOTES S-1 EXISTING SHED cc PROPOSED 3"x12"x.024" ALUMINUM RISER PAN ROOF, FL 16952 OR EQUIV. (ABOVE CTORT EXT.) EXISTING MOBILE HOME _10.4. L 2x4 4TH WALL SMB f 2x3 KNEE 2x6 MID SPAN SMB -------------- --------------- BRACE TYP. EXISTING EXISTING < U CARPORT DRIVEWAY C71 ad L L ---------------- --------------- EXIST . 2 x6 EDGE SMB PROPOSED CARPORT EXT. i r- 3x3x.125 TYP. 2x4 EDGE SMB � EXIST. 4" CONC. SLAB EXIST. 3" RISER PAN ROOF w/8x8 FOOTER (ABOVE EXIST. C-PORT & SHED) EXIST. 3" RISER PAN ROOF PROPOSED 3"x12"x,024" ALUMINUM RISER PAN ROOF, FL 16952 OR EQUIV. EXIST. 2X6 SMB TO REMAIN EXISTING 2x4 EDGE SMB 20 KNEE SHED N BRACE TYP. PROPOSED BEYOND CARPORT EXT. EXIST. 4" CONC. SLAB w/8x8 FOOTER 101_0"_ 20' 2x4 EDGE SMB I HEREBY CERTIE.NT#jAT11R16V, REVIEWED THIS PLAN OW VIN/ COMPLI 9116 AND F TH EDITIQN E .TAAl' NUpEY STIN BU z 0j & F PROFESSIONAL ENGINEER SEAL ENGINEER OF RECORI: David W. SII Ali mith P.E. Thomas L. Hanson P.E. FLORIDA LICENSE NUMBER: 38654 Ian J. Foster P.E. FLORIDA LICENSE NUMBER: 93654 L Joel Falardeau P.E. FLORIDA LICENSE NUMBER: 70667 Erik Stuart P.E. FLORIDA LICENSE NUMBER: 77605 FBC Plans & Engineering Services, Inc. 5344 9th St Zephyrhills, fl. 33542 Phone: (813)838-0735 Website: www.fbcplans.com PROPOSED 3"x12"x.024` ALUMINUM C.O.A. - #29054 RISER PAN ROOF, FL 16952 OR EQUIV. DATE: 02/04/2023 EXIST. 2x6 SMB TO REMAIN DRAWN BY: MARK DUNN SR. EXIST. 3" RISER PAN ROOF 2x6 MID -SPAN SMB 2x4 4TH WALL SMB REVISION: DATE: RO 1 XCARRIEP, SMB i PROPOSED CARPORT EXT. mx w/SHED SHOWN BEYOND 20 KNEE BRACE TYP. EXISTING MOBILE HOME RO 2 RO 3 RO 4 JOB NAME &ADDRESS: CREGG EXIST. 41' CONC. SLAB w/8x8 FOOTER GRAND HORIZONS MHP _01. 1T-0" 37604 NEW HORIZONS BLVD. ZEPHYRHILLS, FL 33541 CONTRACTOR: FRONT ELEVATI®N SUNSTATE ALUMINUM PLANS & ELEVATIONS S-2 I HEREBY CERTIFY THAT I HAVE REVIEWED THIS PLAN AN%kypqVIqO BE IN T COMPLI -iAdMD FBC 7TH EDITM K AND EXING RECOMMEND ALUMINUM FLASHING D EDG INSTALLED BELOW DRIP EDGE, PAN E, .......... C FASTEN ALUM, RISER F A EN ALUM FASTEN A CAULK ALL SEAMS ROOF TO BEAM W/ #10 X 3/4" R 0 0 F To BEAM TEK SCREW AND 3/4"0 T E K SCREW A RISER PAN t N NEPRENE W NEOPRENE WASHER, 4 PER PAN E OPRENE FASTEN ALUM. j 6" MIN. 6- 1 MIN. 3/4 " TEK #8 X 3/4" TEK SCREW AND 1`0 8 �'VS -N(GR ROOF TO 2x EDGE SMB PER PLAN W1#10X AND 3/4"0 3/4" TEK SCREW A P RENE W NEOPRENE WASHER @ EACH RIB N E 0 COP NEOPRENE WASHER, 4 PER PAN it NEW ER PAN ROOF . . . . . . - - - - - - - - - - - - - F EXIST, RISER PAN ROOF f T_ NEW 2x CARRIER ==t=— P FE NAUtONEER SEAL RO (N) SEE CHART 3/8" THRU BOLTS, WALL 2x 4THWALLSMB SMB SMB PER PLAN (N) SEE CHART 3/8" THRU BOLTS, ENGINEER OF RECORD: WASHERS, AND NUTS , 11 93 PEER PLAN WASHERS, AND NUTS, CORROSION RESISTANT I CORROSION RESISTANT David W. Smith P.E. LJJ FLORIDA LICENSE NUMBER: 53608 �E M 0 0 2x— CARRIER BEAM TO '�' '�'. NEW 2x SIAS EDGE SEE BEAM TO POST DETAIL U) z -7 MAY NOTCH SMB PER PLAN 0 < SMB PER PLAN IL _5 CENTER OR I I a. � � Thomas L. Hanson P.E. EDGE OF POST I ---4— 4— _j [L < Z) w FLORA LICENSE NUMBER: 38654 ID 00 < z SEE BEAM TO POST DETAIL, Ian J. Foster P.E. Cr D Uj RISER PAN ROOF, CARRIER BEAM, EDGE FLORIDA LICENSE NUMBER: 93654 _j < BEAM AND POST CONNECTIONS DETAIL E Joel Falardeau P.E. 4TH WALL CONNECTIONS FLORIDA LICENSE NUMBER: 70667 ALUM. RISER PAN ROOF, POST AND BEAM Erik Stuart P.E. FLORIDA LICENSE NUMBER: 77605 FBC Plans & Engineering Services, Inc. 5344 9th St. Zephyrhills, fl. 33542 FASTEN ALUMINUM RISER PAN ROOF TO NEW Phone: (813)838-0735 Website: ww-w.fbcp1ans.corn 2x8 SMB W1 #10 X3/4"TEK SCREW AND 3/4"0 C.O.A. - #29054 FASTEN EXIST, ALUM. RISER PAN NEOPRENE WASHER @ 8" O.C. ROOF TO NEW 2X6 MID SPAN SMB j DATE: 02/04/2023 W/ #10 X 3/4" TEK SCREW AND 3/4"0 EXIST._ ALUM. R_ISER_� NEOPRENE NEOPRENE WASHER, 4 PER PAN PAN ROOF DRAWN BY: MARK DUNN SR. REVISION: DATE: EXIST ALUM.RISER EXIST. 2x6 EDGE SMB PER PLAN PAN ROOF RO 1 NEW ALUM, RISER PAN ROOF RO 2 RO 3 —NEW 2x6 MID SPAN SMB PER PLAN 00 RO 4 NEW 2X9 CARRIER a 0 SMB PER PLAN NEW 2X9 CARRIER SMB PER PLAN FASTEN EXIST. 2X6 EDGE SMB TO JOB NAME & ADDRESS: NEW 2X9 CARRIER SMB ATTACH ALUM. RISER PAN W/(4) 2" X 2" X 0.125" ANGLE ROOF TO HEADER CHANNEL CREGG FASTEN NEW 2X6 MID SPAN SMB W1 #12 X 3/4" TEK SCREW W1 (4) #10 X 3/4" TEK SCREW GRAND HORIZONS MHP TO NEW 2X9 CARRIER SMB (1) SCREW PER INCH OF ANGLE AND VO NEOPRENE WASHER 37604 NEW HORIZONS BLVD, W/(4) 2" X 2" X 0. 125" ANGLE ALL FLANGES/CONNECTION POINTS PER PAN (BACK OF PAN) ZEPHYRHILLS, FL 33541 W/ #12 X 3/4" TEK SCREW (1) SCREW PER INCH OF ANGLE FASTEN HEADER CHANNEL CONTRACTOR: ALL FLANGES/CONNECTION POINTS TO BEAM W1 (2) #10 X 1-1/2" TEK SCREW @ 12" O.C. SUNSTATE ALUMINUM ALUM. RISER PAN ROOF AND BEAM ALUM, RISER PAN ROOF AND BEAM CARPORT EXT. DETAILS S-3 FASTEN SMB TO RECEIVING CHANNEL W/ #10x3/4" TEKS (1 SCREW / INCH OF BEAM HEIGHT) STAGGERED, BOTH SIDES SMB PER PLAN MIN. 060 RECEIVING CHANNEL ALUMINUM FASTENED TO POST W1 #10x3/4' TEKS POST (1 SCREW/ INCH OF BEAM HEIGHT) PER PLAN STAGGERED BEAM TO POST CONNECTION FASTEN RECEIVING CHANNEL TO SMB W1 #10 X 3/4" TEK SCREW (1 SCREW / INCH OF BEAM HEIGHT) STAGGERED, BOTH SIDES 2X SMB PER PLAN FASTEN INTERNAL OR EXTERNAL RECEIVING CHANNEL TO STRUCTURAL WALL MEMBER WITH 1/4"0 X 2" LAG SCREW (1 SCREW / 2 INCHES OF BEAM HEIGHT) El 0 1-1/2" X 2-1/8'X 1-1/2" X 0,062" MIN. INTERNAL OR EXTERNAL RECEIVING CHANNEL 0 0 0 0 _j z C) 2"x3" KNEE BRACE (12"x12") - 45* MIN. ALUMINUM COLUMN LOCATED PER PLAN CONNECT KNEE BRACE TO COLUMN/BEAM WITH.060" MIN. REC, CHANNEL OR GUSSET PLATE FASTEN W/(3)#1Ox3/4" TEKS AT EACH CONNECTION PT. S.M,B, DEPTH 'H' S.M.B, WEB WALL TUBE WALL 'T' 'N' CORROSION RESISTANT SIZE UPLIFT CAPACITY 4' 045' 06' (5 3/8' BOLTS, NUTS, WASHERS 1720 LBS� 5' 050' (2) 3/8' BOLTS, NUTS, WASHERS 2,550 LBS 6' 050' 06- (3) 3/8' BOLTS, NUTS, WASHERS 2 �550LBS 7- .055' 06' (3) 3/8- BOLTS, NUTS, WASHERS 3,500 LBS 7' .055' 1(3.) 3/8' BOLTS, NUTS, WASHERS 3,600 LBS 7' Z55' 125' 1 (3) 3/8' BOLTS, NUTS, WASHERS 4,500 LBS a, .072' 06' (4) 3/8' BOLTS, NUTS, WASHERS 5,500 LBS .072' (4) 3/8- BOLTS, NUTS, WASHERS 7,000 LBS 072' .125' (4) 3/8' BOLTS, NUTS, WASHERS 7,000 LBS 91 072' Z6' (4) 3/8' BOLTS, NUTS, WASHERS 7,000 LBS 91 072' (4) 3/8' BOLTS, NUTS, WASHERS 8,900 LBS A25' (4) 3/8' BOLTS, NUTS, WASHERS ERS 500 LBS .125' (4) 3/8 - BOLTS, NUTS, ;6 WASHERS 19 000 11, LBS NOTEi SITE OTHER BOLT SIZES AND QUANTITIES MAY SPECIFIC PLANS AND CALCULATED UPLIFT BE USED PER CAPACITY REQUIRED #10 X 3/4" TEK SCREW AND 3/4" 0 NEO-PRENE WASHER 4 PER PAN AT ALL BEAMS AND 8" O.C. AT RAKE 3" X 12" ALUM. F RISER PAN ROOF 2X SMB PER PLAN CONNECTION W/ (N) PER CHART 3/8" THRU BOLTS, WASHERS AND NUTS CORROSION RESISTANT TYPICAL ALUMINUM POST I COLUMN PER PLAN I HEREBY CERTIFY THAT I HAVE REVIEWED LAN AND FO, PI 4'4 Tq N COMPLIANCE%1"* tA16rAN6/FTC7TH EDITIONm EXISTIN BUILDIp 0 �fir C 0 F PIOFESSO'� �ALJA - --, te"' PROFESSIO WN SEAL David W. Smith P.E. FLORIDA LICENSE NUMBER: 53608 FLORIDA LICENSE NUMBER: 38654 Ian J. Foster P.E. FLORIDA LICENSE NUMBER: 93654 Joel Falardeau P.E. FLORIDA LICENSE NUMBER: 70667 Erik Stuart P.E. FLORIDA LICENSE NUMBER: 77605 I Met 5344 9th St. Zephyrhills, fl. 33542 Phone: (813)838-073S Website: www.fbcplans.com C.O.A. - #29054 DATE: 02/04/2023 DRAWN BY: MARK DUNN SR. TOP VIEW NOTE: OPTION 1 -(1) 112"0 LDT CONCRETE SCREW MINIMUM EMBEDMENT OF ANCHORS INTO REVISION: DATE: PER OUTER FLANGE AS SHOWN, CONCRETE FOOTING SHALL BE 2-3/4" AT ALL WITH 2-3/4" EMBEDMENT POST LOCATIONS, ALL SCREW LENGTHS AT RO 1 (MIN. CONCRETE EDGE DISTANCE - 3") POST CONNECTIONS SHALL BE OF SUFFICIENT LENGTH FOR REQUIRED EMBEDMENT INTO RO 2 CONCRETE WHEN A PAVER DECK IS PRESENT. RO 3 (2) 3/8"0 MACHINE BOLTS WITH WASHERS OR ALUM. SQUARE COLUMN / POST RO 4 (4) #14 X 3/4' SMS EACH SIDE 2" X 2" X 0. 125" ANGLE EXTERNAL OR EQUIVALENT POST BASE OPTION 2:- (2)3/8" CONCRETE ANCHORS PER EXTERIOR FLANGE, 14AII OPTION #3' JOB NAME &ADDRESS: MIN. DISTANCE BETWEEN - 2" O.C_ FOR INTERNAL FASTENING (4) 1/4"0 WITH 2-3/4" EMBEDMENT CONCRETE SCREW WITH 3" EMBEDMENT CREGG (MIN. CONCRETE EDGE DIST NCE - 3") (MIN. EDGE DISTANCE 3" AND MIN. SPACING 2") GRAND HORIZONS MHP 37604 NEW HORIZONS BLVD, ZEPHYRHILLS, FL 33541 CONTRACTOR: FRONT VIEW 3x3 POST TO CONCRETE SUNSTATE ALUMINUM CARPORT EXT. DETAILS S-4