HomeMy WebLinkAbout23-56525335 Eighth Street
Zephyrhills, FL 33542
Phone: (813) 780-0020
Fax: (813) 780-0021 1
-
issue Date: 02/1312023
REINSPECTION FEES: (c) With respect to Reinspection fees will comply with Florida Statute 553.80(2)(c) the
local government shall impose a fee of four times the amount of the fee imposed for the initial inspection or
first reinspection, whichever is greater, for each subsequent reinspection.
Notice: In addition to the requirements of this permit, there may be additional restrictions applicable to this property that
may be found in the public records of this county, and there may be additional permit required from other governmental
entities such as water management, state agencies or federal agencies.
"Warning to owner: Your failure to record a notice of commencement may result in your paying twice f9
accordance with City Codes and Ordinances. NO OCCUPANCY BEFORE C.O.
NO OCCUPANCY BEFORE C.O.
�EATRACTOR SlibKATURE PE IMIT OFFICEV
RMIT EXPIRES IN 6 MO NTHS WITHOUT APPROVED INSPECTION
, rillwit,
%Sol
813-780-0020 City of Zephyrhills Permit Application Fax-813-780-0021
Building Department
Date Received 03/07/20 Phone Contact for Permitting 1(727 ) 294 __7218
Ilt a 1 0 1 X I a i[X3130=
Owner's Name Vicky Irizarry Owner Phone Number 1813-469-5705
Owner's Address 16353 Bradford Woods Dr. Owner Phone Number
Fee Simple Titleholder Name Owner Phone Number
Fee Simple Titleholder Address
JOB ADDRESS 6353 BradfardWoods Dr. Zephryhills Fl 33542 LOT #
SUBDIVISION Oaks of Pasco PARCEL iD#1 04-26-21-0120-00000-0660
(OBTAINED FROM PROPERTY TAX NOTICE)
WORK PROPOSED NEW CONSTR F—] ADD/ALT SIGN DEMOLISH
R INSTALL REPAIR
PROPOSED USE SFR COMM OTHER E_
TYPE OF CONSTRUCTION BLOCK FRAME STEEL =
DESCRIPTION OF WORK Revision:Mod Swap to 25 Freedom Forever 400Ws
BUILDING SIZE C So FOOTAGE = HEIGHT
=BUILDING 11 VALUATION OF TOTAL CONSTRUCTION -549.00
=ELECTRICAL 1 $_549.00 AMP SERVICE PROGRESS ENERGY W.R.E.C.
=PLUMBING 1$
=MECHANICAL VALUATION OF MECHANICAL INSTALLATION
= GAS ROOFING SPECIALTY = OTHER
FINISHED FLOOR ELEVATIONS I I FLOOD ZONE AREA =YES NO
BUILDER COMPANY I I
SIGNATURE REGISTERED I Y/N I FEE CURREN I Y/N I
Address License #
ELECTRICIAN COMPANY � Frep4om Forever
SIGNATURE REGISTERED 1lYl1N I FEE CURREN TTY-VN I
Address F_ License# I EC13008056 I
PLUMBER COMPANY I ^ I
SIGNATURE REGISTERED L_Y / N FEE CURREN L_Y N
Address License #
MECHANICAL COMPANY
SIGNATURE REGISTERED Y/N FEE CURREN
Address License
OTHER COMPANY
SIGNATURE REGISTERED / N FEE CURREN
Address F License# E
RESIDENTIAL Attach (2) Plot Plans; (2) sets of Building Plans; (1) set of Energy Forms, R-O-W Permit for new construction,
Minimum ten (10) working days after submittal date. Required onsite, Construction Plans, Stormwater Plans w/ Silt Fence installed,
Sanitary Facilities & 1 dumpster, Site Work Permit for subdivisions/large projects
COMMERCIAL Attach (2) complete sets of Building Plans plus a Life Safety Page; (1) set of Energy Forms. R-O-W Permit for new construction.
Minimum ten (10) working days after submittal date. Required onsite, Construction Plans, Stormwater Plans w/ Silt Fence installed,
Sanitary Facilities & 1 dumpster, Site Work Permit for all new projects. All commercial requirements must meet compliance
SIGN PERMIT Attach (2) sets of Engineered Plans.
-PROPERTY SURVEY required for all NEW construction.
Directions:
Fill out application completely.
Owner & Contractor sign back of application, notarized
If over $2500, a Notice of Commencement is required. (A/C upgrades over $7600)
— Agent (for the contractor) or Power of Attorney (for the owner) would be someone with notarized letter from owner authorizing same
OVER THE COUNTER PERMITTING (copy of contract required)
Reroofs if shingles Sewers Service Upgrades A/C Fences (Plot/Survey/Footage)
Driveways -Not over Counter if on public roadways -needs ROW
813-780-0020 City of Zephyrhills Permit Application Fax-813-780-0021
Building Department
NOTICE OF DEED RESTRICTIONS: The undersigned understands that this permit may be subject to "deed" restrictions" which may be more restrictive
than County regulations. The undersigned assumes responsibility for compliance with any applicable deed restrictions.
UNLICENSED CONTRACTORS AND CONTRACTOR RESPONSIBILITIES: If the owner has hired a contractor or contractors to undertake work, they
may be required to be licensed in accordance with state and local regulations. If the contractor is not licensed as required by law, both the owner and
contractor may be cited for a misdemeanor violation under state law. If the owner or intended contractor are uncertain as to what licensing requirements
may apply for the intended work, they are advised to contact the Pasco County Building Inspection Division —Licensing Section at 727-847- 8009.
Furthermore, if the owner has hired a contractor or contractors, he is advised to have the contractor(s) sign portions of the "contractor Block" of this
application for which they will be responsible. If you, as the owner sign as the contractor, that may be an indication that he is not properly licensed and is
not entitled to permitting privileges in Pasco County.
TRANSPORTATION IMPACTIUTILITIES IMPACT AND RESOURCE RECOVERY FEES: The undersigned understands
that Transportation Impact Fees and Recourse Recovery Fees may apply to the construction of new buildings, change of use in existing buildings, or
expansion of existing buildings, as specified in Pasco County Ordinance number 89-07 and 90-07, as amended. The undersigned also understands, that
such fees, as may be due, will be identified at the time of permitting. It is further understood that Transportation Impact Fees and Resource Recovery
Fees must be paid prior to receiving a "certificate of occupancy' or final power release. If the project does not involve a certificate of occupancy or final
power release, the fees must be paid prior to permit issuance. Furthermore, if Pasco County Water/Sewer Impact fees are due, they must be paid prior
to permit issuance in accordance with applicable Pasco County ordinances.
CONSTRUCTION LIEN LAW (Chapter 713, Florida Statutes, as amended): If valuation of work is $2,500.00 or more, I certify that I, the applicant,
have been provided with a copy of the "Florida Construction Lien Law —Homeowner's Protection Guide" prepared by the Florida Department of
Agriculture and Consumer Affairs. If the applicant is someone other than the "owner", I certify that I have obtained a copy of the above described
document and promise in good faith to deliver it to the "owner' prior to commencement.
CONTRACTOR'SIOWNER'S AFFIDAVIT: I certify that all the information in this application is accurate and that all work will be done in compliance with
all applicable laws regulating construction, zoning and land development. Application is hereby made to obtain a permit to do work and installation as
indicated. I certify that no work or installation has commenced prior to issuance of a permit and that all work will be performed to meet standards of all
laws regulating construction, County and City codes, zoning regulations, and land development regulations in the jurisdiction. I also certify that I
understand that the regulations of other government agencies may apply to the intended work, and that it is my responsibility to identify what actions I
must take to be in compliance. Such agencies include but are not limited to:
- Department of Environmental Protection -Cypress Bayheads, Wetland Areas and Environmentally Sensitive
Lands, Water/Wastewater Treatment.
Southwest Florida Water Management District -Wells, Cypress Bayheads, Wetland Areas, Altering
Watercourses.
Army Corps of Engineers -Seawalls, Docks, Navigable Waterways.
Department of Health & Rehabilitative Services/Environmental Health Unit -Wells, Wastewater Treatment,
Septic Tanks.
US Environmental Protection Agency -Asbestos abatement.
Federal Aviation Authority -Runways.
I understand that the following restrictions apply to the use of fill:
Use of fill is not allowed in Flood Zone W" unless expressly permitted.
If the fill material is to be used in Flood Zone "A", it is understood that a drainage plan addressing a
"compensating volume" will be submitted at time of permitting which is prepared by a professional engineer
licensed by the State of Florida.
If the fill material is to be used in Flood Zone "A" in connection with a permitted building using stem wall
construction, I certify that fill will be used only to fill the area within the stem wall.
If fill material is to be used in any area, I certify that use of such fill will not adversely affect adjacent
properties. If use of fill is found to adversely affect adjacent properties, the owner may be cited for violating
the conditions of the building permit issued under the attached permit application, for lots less than one (1)
acre which are elevated by fill, an engineered drainage plan is required.
If I am the AGENT FOR THE OWNER, I promise in good faith to inform the owner of the permitting conditions set forth in this affidavit prior to
commencing construction. I understand that a separate permit may be required for electrical work, plumbing, signs, wells, pools, air conditioning, gas, or
other installations not specifically included in the application. A permit issued shall be construed to be a license to proceed with the work and not as
authority to violate, cancel, alter, or set aside any provisions of the technical codes, nor shall issuance of a permit prevent the Building Official from
thereafter requiring a correction of errors in plans, construction or violations of any codes. Every permit issued shall become invalid unless the work
authorized by such permit is commenced within six months of permit issuance, or if work authorized by the permit is suspended or abandoned for a
period of six (6) months after the time the work is commenced. An extension may be requested, in writing, from the Building Official for a period not to
exceed ninety (90) days and will demonstrate justifiable cause for the extension. If work ceases for ninety (90) consecutive days, the job is considered
abandoned.
•1":,@ 241;4 1 Ji•♦ &XkC I U =13 WM 1 W41614is A, 001 qn4jiWasolmolve
FLORIDA JURAT (F.S. 117.03)
OWNER OR AGENT
Subscribed and sworn to (or affirmed) before me this
Who is/are personally known to me or has/have produced
as identification.
Notary Public
Commission No.
me or
as identification.
r
�� � �
i.1��W
_Notary Public
Commission No.
E{i
ffzf`4,t:
Name of Notary typed, printed or stamped Name of Notary typed, anted or stamped
SIERRA C GRA
Y
"rotarV Public - State of Merida
^ Gorrlmissfon ;t itl 114656
My COMM Expires Arr 6; 2025
BerdedthroaghNationafNotary Assn,
I 1 0 A
lgflnwilmrfgy� ='. rkwmmm�m' F F G-M-M-M Im I
THIS INSTRUMENT PREPARED BY:
Name; Freedom F..-,. LLC
Address: 2619 consulate Or, Ste 800
04ando, FL 32819
Permit Number: --- — 7-- , , -3 =
Parcel ID Numb.� -, - �-2- �T)� T �-- -, �D' �) E
The undersigned hereby gives notice that improvement will be made to certain real property, and in accordance with Chapter 713, Florida Statutes, the
following information is provided in this Notice of Commencement.
r10r6T4TT_jMR• •
(Legal description of the
2. GENERAL DESCRIPTION OF IMPROVEMENT:
Installation of photovoltaic solar panels on rooftop,
and street address if available)
14 "k / r__1'T t, (.
3. OWNER INFORMATION OR LESSEE INFORMATION IF THE LESSEE CONTRACTED FOR THE IMPROVEMENT:
Name and address-,
Interest in property: owner
Fee Simple Title Holder (if other than owner listed above) Name:
Address:
4. CONTRACTOR: Name: Freedom Forever, LLC —
Address: 2010 51 st Ave E Ste 111 Palmetto FI 34221
Phone Number: 727-294-7218
5, SURETY (if applicable, a copy of the payment bond is attached): Name:
Address:
6, LENDER: Name: Phone Number:
Amount of Bond
Address:
7. Persons within the State of Florida Designated by Owner upon whom notice or other documents maybe served as provided by Section
713.13(1)(a)7., Florida Statutes.
8, in addition, Owner designates
Phone Number:
Of
to receive a copy of the Lienor's Notice as provided in Section 713.13(1)(b), Florida Statutes. Phone number:
9, Expiration Date of Notice of Commencement (The expiration is 1 year from date of recording unless a different date is specified)
WARNING TO OWNERS ANY PAYMENTS MADE BY THE OWNER AFTER THE EXPIRATION OF THE NOTICE OF COMMENCEMENT ARE
CONSIDERED IMPROPER PAYMENTS UNDER CHAPTER 713, PART 1, SECTION 713.13, FLORIDA STATUTES, AND CAN RESULT IN YOUR
PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY, A NOTICE OF COMMENCEMENT MUST BE RECORDED AND POSTED ON THE
JOB SITE BEFORE THE FIRST INSPECTION. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY
BEFORE COMMENCING WORK OR RECORDING YOUR NOTICE OF COMMENCEMENT.
X
Mrnt Name and Provide SilinatorysTidatOfflou)
State of C.t County of
The foregoing instrument was a IV, owl f, to me b means of day of
ck Z ge PwI before
physical presence or online notarization, this
li -40L (name of person acknowledging), who is personally known to me; or
has produced,,���. as identification.
SIERRA C GRAY
Signature �ofNo a Pu
Notary hbItc - State of Florida
Commission # HH 114656
ct My Comm. Expires Apr 6, 2025
Bonded through National Notary Assn.
813-780-0020 City of Zephyrhills Permit Application Fax-813-780-0021
Building Department
Date Received 02/13/2023
Phone Contact for Permitting 727 294 __7218
4 a a *'I * * a�K�
Owner's Name ViCky M Irizarry Owner Phone Number 1813-269-5705
Owner's Address [6:3:5::Bradford
:3 B fOrd Woods Dr, Owner Phone Number ::
Fee Simple Titleholder Name Owner Phone Number
Fee Simple Titleholder Address
JOB ADDRESS 16353 Bradford Woods Dr. LOT # 66
SUBDIVISION Oaks of Pasco PARCEL lo# 104-26-21-0120-00000-0660
(OBTAINED FROM PROPERTY TAX NOTICE)
WORK PROPOSED
NEW CONSTR ADD/ALT SIGN DEMOLISH
R
INSTALL REPAIR
R
PROPOSED USE SFR o COMM OTHER Fswa
TYPE OF CONSTRUCTION BLOCK 0 FRAME 0 STEEL
DESCRIPTION OF WORK
Installation of PN Solar Panels on rooftop.
I I 563.93
BUILDING SIZE Sol FOOTAGE HEIGHT
xx Vxxx XXVx XXXIEIEX X�Utx XVIC xx VV I XIEX&X WALX xWVVVWV)CW VIE xx x
BUILDING
r==
VALUATION OF TOTAL CONSTRUCTION
®ELECTRICAL $ 28,864.00 AMP SERVICE PROGRESS ENERGY W, R. E. C,
=PLUMBING
=MECHANICAL
$
VALUATION OF MECHANICAL INSTALLATION
=GAS ROOFING SPECIALTY = OTHER
FINISHED FLOOR ELEVATIONS
FLOOD ZONE AREA =YES NO
BUILDER
COMPANY
SIGNATURE
REGISTERED L_Y_LN_j FEE CURREN Lyj N
Address License #
ELECTRICIAN
COMPANY
FEC13008,056 + Zl?"' _ItK.� *14
SIGNATURE REGISTERED LILN FEE CURREN
etc
Address License #
PLUMBER
COMPANY
I
SIGNATURE
REGISTERED L N FEE CURREN L
Address I License #
MECHANICAL
COMPANY
SIGNATURE
REGISTERED / N FEE CURREN Y/N
Address I License #
OTHER
COMPANY
SIGNATURE
REGISTERED L_Y / N FEE CURREN Y/N
Address License #
RESIDENTIAL Attach (2) Plot Plans (2) sets of Building Plans (1) set of Energy Forins, R-O-W Permit for new construction,
Minimum ten (10) working days after submittal date. Required onsite, Construction Plans, Stormwater Plans w/ Silt Fence installed,
Sanitary Facilities & 1 dumpster; Site Work Permit for subdivisions/large projects
COMMERCIAL Attach (2) complete sets of Building Plans plus a Life Safety Page, (1) set of Energy Forms, R-O-W Permit for new construction.
Minimum ten (10) working days after submittal date. Required onsfe, Construction Plans, Stormwater Plans w/ Silt Fence installed,
Sanitary Facilities & I dumpster, Site Work Permit for all new projects. All commercial requirements must meet compliance
SIGN PERMIT Attach (2) sets of Engineered Plans.
—PROPERTY SURVEY required for all NEW construction.
Directions:
Fill out application completely.
Owner & Contractor sign back of application, notarized
If over $2500, a Notice of Commencement is required. (A/C upgrades over $7500)
** Agent (for the contractor) or Power of Aftomey (for the owner) would be someone with notarized letter from owner authorizing same
OVER THE COUNTER PERMITTING (copy of contract required)
Reroofs if shingles Sewers Service Upgrades A/C Fences (PloUSurvey(Footage)
Driveways -Not over Counter if on public roadways..needs ROW
813-780-0020 City of Zephyrhills Permit Application Fax-813-780-0021
Building Department
NOTICE OF DEED RESTRICTIONS: The undersigned understands that this permit may be subject to "deed" restrictions" which may be more restrictive
than County regulations. The undersigned assumes responsibility for compliance with any applicable deed restrictions.
UNLICENSED CONTRACTORS AND CONTRACTOR RESPONSIBILITIES: If the owner has hired a contractor or contractors to undertake work, they
may be required to be licensed in accordance with state and local regulations. If the contractor is not licensed as required by law, both the owner and
contractor may be cited for a misdemeanor violation under state law. If the owner or intended contractor are uncertain as to what licensing requirements
may apply for the intended work, they are advised to contact the Pasco County Building Inspection Division —Licensing Section at 727-847- 8009.
Furthermore, if the owner has hired a contractor or contractors, he is advised to have the contractor(s) sign portions of the "contractor Block" of this
application for which they will be responsible. If you, as the owner sign as the contractor, that may be an indication that he is not properly licensed and is
not entitled to permitting privileges in Pasco County.
TRANSPORTATION IMPACT/UTILITIES IMPACT AND RESOURCE RECOVERY FEES: The undersigned understands
that Transportation Impact Fees and Recourse Recovery Fees may apply to the construction of new buildings, change of use in existing buildings, or
expansion of existing buildings, as specified in Pasco County Ordinance number 89-07 and 90-07, as amended. The undersigned also understands, that
such fees, as may be due, will be identified at the time of permitting. It is further understood that Transportation Impact Fees and Resource Recovery
Fees must be paid prior to receiving a "certificate of occupancy" or final power release. If the project does not involve a certificate of occupancy or final
power release, the fees must be paid prior to permit issuance. Furthermore, if Pasco County Water/Sewer Impact fees are due, they must be paid prior
to permit issuance in accordance with applicable Pasco County ordinances.
CONSTRUCTION LIEN LAW (Chapter 713, Florida Statutes, as amended): If valuation of work is $2,500,00 or more, I certify that 1, the applicant,
have been provided with a copy of the "Florida Construction Lien Law —Homeowners Protection Guide" prepared by the Florida Department of
Agriculture and Consumer Affairs. If the applicant is someone other than the "owner', I certify that I have obtained a ropy of the above described
document and promise in good faith to deliver it to the "owner' poor to commencement.
CONTRACTOR'S/OWNER'S AFFIDAVIT: I certify that all the information in this application is accurate and that all work will be done in compliance with
all applicable laws regulating construction, zoning and land development. Application is hereby made to obtain a permit to do work and installation as
indicated. I certify that no work or installation has commenced prior to issuance of a permit and that all work will be performed to meet standards of all
laws regulating construction, County and City codes, zoning regulations, and land development regulations in the jurisdiction. I also certify that I
understand that the regulations of other government agencies may apply to the intended work, and that it is my responsibility to identify what actions I
must take to be in compliance. Such agencies include but are not limited to:
Department of Environmental Protection -Cypress Bayheads, Wetland Areas and Environmentally Sensitive
Lands, Water/Wastewater Treatment.
Southwest Florida Water Management District -Wells, Cypress Bayheads, Weiland Areas, Altering
Watercourses.
Army Corps of Engineers -Seawalls, Docks, Navigable Waterways.
Department of Health & Rehabilitative Services/Environmental Health Unit -Wells, Wastewater Treatment,
Septic Tanks.
USEnvironmental Protection Agency -Asbestos abatement.
Federal Aviation Authority -Runways.
I understand that the following restrictions apply to the use of fill
Use of fill is not allowed in Flood Zone W" unless expressly permitted.
If the fill material is to be used in Flood Zone "A", it is understood that a drainage plan addressing a
"compensating volume" will be submitted at time of permitting which is prepared by a professional engineer
licensed by the State of Florida.
If the fill material is to be used in Flood Zone "A" in connection with a permitted building using stem wall
construction, I certify that fill will be used only to fill the area within the stem wall.
If fill material is to be used in any area, I certify that use of such fill will not adversely affect adjacent
properties. If use of fill is found to adversely affect adjacent properties, the owner may be cited for violating
the conditions of the building permit issued under the attached permit application, for lots less than one (1)
acre which are elevated by fill, an engineered drainage plan is required.
If I am the AGENT FOR THE OWNER, I promise in good faith to inform the owner of the permitting conditions set forth in this affidavit prior to
commencing construction. I understand that a separate permit may be required for electrical work, plumbing, signs, wells, pools, air conditioning, gas, or
other installations not specifically included in the application. A permit issued shall be construed to be a license to proceed with the work and not as
authority to violate, cancel, alter, or set aside any provisions of the technical codes, nor shall issuance of a permit prevent the Building Official from
thereafter requiring a correction of errors in plans, construction or violations of any codes. Every permit issued shall become invalid unless the work
authorized by such permit is commenced within six months of permit issuance, or if work authorized by the permit is suspended or abandoned for a
period of six (6) months after the time the work is commenced. An extension may be requested, in writing, from the Building Official for a period not to
exceed ninety (90) days and will demonstrate justifiable cause for the extension. If work ceases for ninety (90) consecutive days, the job is considered
abandoned.
OWNER OR AGENT CONTRACTOR®
Subscribed and sworn to (or affirmed) before me this Subscribed and sy,
by by
Who is/are personally known to me or has/have produced Who is/are persom
as identification.
Notary Public — ('y - C C-51 Nvk Notary Public
Commission No, Commissionvo.. I To
I rc-vy
Name of Notary typed, printed or stamped Name of Notary p , printed or stamped I
Commission
SIERRA C GRAY
Notary Public - State of
;X7, Commission# HH 114656
OF N�,' My Comm. Expires Apr 6, 2025
Sorided through National Notary Assn.
j
Proiect Name: VICKY IRIZARRY RESIDENCE, 6353 BRADFORD WOODS DRIVE, ZEPHYRHILLS, FL
33542
Installation of a 10-27 kW (DC) Rooftop PV Solar System
Per Florida Statute 377-705 (revised 7/01/2017), 1, Mike Rieth, P.E., a licensed engineer pursuant to Chapter
471, certify that the PV electrical system and electrical components are designed and approved using the code
requirements and standards contained in the Florida Building Code.
Mike Rieth, P.E.
miker@baruncorp.com
0A1111111111
L %
%CE 3
4�'"4e
o.94884
STATE OF
0 R V)
�;1,�,S, IONP�j
Banin Caqp, Design , rd Enginee,ing, 1 ch,sk@bawncorp c,*I-1-, 1
A� �Xk' In
February 9, 2023
RE:
Project Address:
Design Criteria:
CERTIFICATION LETTER
VICKY IRIZARRY RESIDENCE
Applicable Codes = 2020 FLBC/FLEBC 7th Edition, 2020 FLRC 7th Edition, 2018 IEBC/IBC, ASCE 7-16 and 2018 NOS
Risk Category = 11
Wind Speed = 145 mph, Exposure Category C, Partially/Fully Enclosed Method
Ground Snow Load = 0 psf
ROOF I - 3: 2 x 4 @ 24" OC, Roof DL = 7 psf, Roof LL/SL = 19 psf (Non-PV), Roof LL/SL = 0 psf (PV)
To Whom It May Concern,
A structural evaluation of loading was conducted for the above address based on the design criteria listed above.
Existing roof structural framing has been reviewed for additional loading due to installation of Solar PV System on the roof. The structural
review applies to the sections of roof that is directly supporting the Solar PV System.
Based on this evaluation, I certify that the alteration to the existing structure by installation of the Solar PV System meets the prescriptive
compliance requirements of the applicable existing building and/or new building provisions adopted/referenced above.
Additionally, the Solar PV System assembly (including attachment hardware) has been reviewed to be in accordance with the manufacturer's
specifications and to meet and/or exceed the requirements set forth by the referenced codes.
Sincerely, k I I I i I I
L
..... 401'
C E N
N 95019
o.
ST E OF
Barun, Corp] Design and Engineering 1610,202,4506 1 chrisk@,bawncorp com j wwmbaruncorp.corn -1/5
�LM,Lti--QL�MmLqf A Nkty-11
The existing sttuctture has been reviewed baNed on the assorriprion, thot it has been originafly designed and constructed per ap'DroprObe
(,-Od,s, The structural cinalosir, of the sobject propertv is baSed on the provided s'ne survey date, The calculations ritodoced tol' this
struchIre's cissessn-rent arre only ,for the rooffranwrig stipporang the orlsoosed PV hnstallotion, referenced in the stompea planset and were
n-tods., according to gel7erafly, recognized stri-icturol anislysis standards and procedures. All [IV ,nodules, racking annattachtnent
1) -so's cipproved guidelines and specifications, Fhese plons are not stornpedfor
cce'nsesnents Shalt e designed and installed per manufoctut
water heakoge or existing damoge to the Mruc"Ural corr, ' ponent that was not accessed during the site skirt Feror to corm-nencercent a
I hr I r? - -
work,, the Fps syserl-, � istaller should verify thist the existing roof and connections are I suitable condition and in.5pectfroming noteri oo
the certrficotjcin lemer and inform the Fogirreer of Record ojf any di Creponcies prior to instoliation, 7-he instafler should cillso checefor any
r the Engereer, qF Recon.1 of exist�nq de,,ficiencif"s which are unknown
lm.,nages such ols water daniage, cracke from ng, etc. arld inforr)
C`17ci/cr, were nclt observable during !tie time ofstevey and hove not been ioch,,�(Jed in this scope of anwk. Any change in the scope Qf the
rvork shall not be accepted um.ess such change, adrfition, or deletion is approved in advaace andin writing by the Engineer ofiRecord,
Bawn Corp 1, Design and, Engineering 16-1110 202,4506 j chnsK@baruncor.rp corn I leovev,baruncorp,com 2/5
Roof Live Load Lo = 20.00 psf
Member Tributary Area At < 200 ft2
ROOF I - 3 Pitch 23' or 5/12
Tributary Area Reduction Factor RI = 1.00
Roof Slope Reduction Factor R2 = 0.95
Reduced Roof Live Load, Lr = Lo (RI) (RZ) Lr = 19.00 psf
Ground Snow Load
pg = 0.00 psf
Effective Roof Slope
23'
Snow Importance Factor
Is = 1.00
Snow Exposure Factor
Ce = 1.00
Snow Thermal Factor
Ct = 1.10
Minimum Flat Roof Snow Load
pf-min = 0.00 psf
Flat Roof Snow Load
r� Pf = 0.00 psf
"L -neering 1610,202,4506 ch, nsk@ baru ncor p, corn wv'('.V.baruncorp,Co1r,,, 3/5
Banun Cor, Design and Enpg
IMM-0 =d, IV TIM? TOTT
Roof Live Load (Lr)
OEM
psf
Psf
osf
20.56
10.78
Load Increase (%) =1 -4M8% 1 c, �<
The requirements of section 806.2 of 2018 IEBC are met and the structure is permitted to remain unaltered.
Barun Cor,,,-) Desginand Engineering 6-110 202 4506 1 chrisk( barwnicorp,com I wwNiv,baruncono.com 4/5
NOM
® Wind calculation is based on ASCE 7-16, 29.4 - C&C, LC #7: 0.6DL + 0.6WL is used.
1 5/5
Balruin, Corr) i Desiqn and Er-igineerinq i 610202,4506 1; ch risk@ bar uncorp, com 1 .APvA,,/.baruincorp-cor-n
°
Freedom Forever 2/38/2023
P|anast Revision Letter REV#1
Attn. City ofZaphyrhUls:
The changes outlined in Revision Details have been applied to the plans corresponding to
the following customer:
1)[Noduleachanged from (26)HANVYHA0CELL:O.PEAKDUO L-G5.2305to(l5)FREEDOM FOREVER:
FF-MP'BBB-400.
2)Layouthas been changed.
Thank you for your time in reviewing these plans. Please reach out if you have any additional questions or
Construction Engineering
Freedom Forever
BARUN CORP
March 2, 2023
I
Project Name: VIA KY IRIZARRY RESIDENCE, 6353 BRA FOR WOODS DRIVE, ZEPHYRHILLS, FL
33542
Installation of a 10 kW (DC) Rooftop PV Solar System
Per Florida Statute 377-705 (revised 7/01/2017), 1, Mike Rieth, P.E., a licensed engineer pursuant to Chapter
471, certify that the PV electrical system and electrical components are designed and approved using the code
requirements and standards contained in the Florida Building Code.
If you have any questions regarding this project, please feel free to contact me.
Sincerely,
Mike Rieth, P.E.
miker@baruncorp,com
X�% 1AJ111111/111
C E N
N0.94884
'Z7 TA .o
ONAI-V
1111111110\
'3R1,,),'oro com
f,3aru,,C1 Cr, -Trl Desw ar'Vd 6,,"" 20'24506 ;,vwvv barl incc,7 ti o-n
Freedom Forever 2/28/2023
Planset Revision Letter REV#I
The changes outlined in Revision Details have been applied to the plans corresponding
the fllowing customer: i
o
VICKY IRIZARRY
6353 BRADFORD WOODS DRIVE, ZEPHYRHILLS, FL 33542
Revision Details:
1)Modules changed from (26) HANWHA QCELL: Q.PEAK DUO L-G5.2 395 to (25) FREEDOM FOREVER:
FF-MP-BBB-400.
2)Layout has been changed.
7! 11 Ili I �i I i !I i I!•! I i I Irii I I I i 1! 1111!! 1 i I!! I I •
A1111111 MEMOSMW
Thank you for your time in reviewing these plans. Please reach out if you have any additional questions or
concerns,
Construction Engineering
Freedom Forever
March 1, 2023
RE:
Project Address:
Design Criteria:
CERTIFICATION LETTER
VICKY IRIZARRY RESIDENCE
Applicable Codes = 2020 FLBC/FLEBC 7th Edition, 2020 FLRC 7th Edition, 2018 IEBC/IBC, ASCE 7-16 and 2018 NDS
Risk Category = 11
Wind Speed = 145 mph, Exposure Category C, Partially/Fully Enclosed Method
Ground Snow Load = 0 psf
ROOF 1- 3: 2 x 4 @ 24" OC, Roof DL = 7 psf, Roof LL/SL = 19 psf (Non-PV), Roof LL/SL = 0 psf (PV)
To Whom It May Concern,
A structural evaluation of loading was conducted for the above address based on the design criteria listed above.
Existing roof structural framing has been reviewed for additional loading due to installation of Solar PV System on the roof. The structural
review applies to the sections of roof that is directly supporting the Solar PV System.
Based on this evaluation, I certify that the alteration to the existing structure by installation of the Solar PV System meets the prescriptive
compliance requirements of the applicable existing building and/or new building provisions adopted/referenced above.
Additionally, the Solar PV System assembly (including attachment hardware) has been reviewed to be in accordance with the manufacturer's
specifications and to meet and/or exceed the requirements set forth by the referenced codes.
Sincerely,
I If /1/1///
L
N. 95019
R/g, 3
TATE OF
fp
Barun Corp Design and Engineering 1 610,20Z4506 1 chrisk6&,barun,-,orp,com 1 wmrov baruncorp.com 1/5
LL,jfts qL, ad -i(Ib UL: -L -�IL
The exisfing structure has beef, reviewed based ivn the assumptioa that it hms been originally designed w-rd constructed per appropaantl
c1
odes, The structural onael is (-if the sutton-t property is based or, the provided site suriley data, The carcu"Citions produced for this
fs
structure's assessment ore reVir r the rooffirorning Stir) no" horg 1-h-e Pro'nosed PV iristollc6ort referenced in the starroed olary-set and were
I fol I P I I
made according to generally recognized strt;ctural ant'.nyths, standards, and Procedures, All PV inciduief, axiling and artachmen,
components shall be des' fined and installed Pet -wrtufacturer's apProved guideflnes and specifications, These plisns or nor stornped jor
water leokoge or emifting dantoge to the structural component that was riot accessea during the site survey. Firior to corritnencernert. , of
W/Ofk, the Piv SyStato iroitm'ler should verify that khe existing , oqf and connections are in stn'toble condition and e inspectfrann' noted' on
l-
CT
e ce'rtibcation le ttet and ini"Orn i tare Engineer clf Record of ony docrepancies prior &o ins toff ation . T h e installer sh outd' also check for
-ean ages such os ovaihcr dornage crocked frisirting nor. and inforro the Engineer of Record, ca- existing de, ficiencies which ore unknown
to /ot aere tsT observable during, the pive of survey re -id hove Pott been it) this scope of olork. Any chan e in the c0s'pe of the
9
wcekshoO not be accepted urtless such change, addlNon, or de/etion is approved P7 advance and in writing by Ow Engfn.eer isfRecord,
3 Desiar, cand C-lilp -HHg,� 610,, 2024506 wilteel, bar uncorp. com Barun Corp —2/5
Roof Live Load
Lo = 20.00 psf
Member Tributary Area
At < 200 ft'
ROOF 1 - 3 Pitch
23' or 5/12
Tributary Area Reduction Factor
R1= 1.00
Roof Slope Reduction Factor
R2 = 0.95
Reduced Roof Live Load, lur = Lo (1111) (1112)
Lr = 19.00 psf
Ground Snow Load
pg = 0.00 psf
Effective Roof Slope
23'
Snow Importance Factor
Is = 1,00
Snow Exposure Factor
Ce = 1.00
Snow Thermal Factor
Ct = 1.10
Minimum Flat Roof Snow Load
pf-min = 0.00 psf
Flat Roof Snow Load
Pf = 0.00 psf
Barlun Con'D 11 Design and Engineering 6,10,202,4506 1 ct-,:riskg,,,,barun,r,,ocom i Vvw%ki,baruncorp.corn 3/5
Roof Live Load (Lr cl
Load Increase (%) =1 -47.58% 10
BarUn Corp ! Design aind EEngineedng 6110,2012,4506 c�',risk@baruncorp.com 1 \N,,Ar,,�,,,,bar�jncorlp-co,,,z-1 4 /5
NOTE:
- Wind calculation is based on ASCE 7-16, 29A - C&C, LC #7: 0.61DL + 0.6WL is used.
F.',,arun Corp 3 Design and Engineering 16,10,202,41506 1 ch risk@ ba runcorp, com I wAmv.baruncorp.corn, 5/5
.00F .
NT PHOTOVOLTAIC SYSTEM H
COMPLIES
THIS PROJECT
2020 7TH EDITION FLORIDA BUILDING CODE
EDITION•
EDITION.r
2020 7TH EDITION FLORIDA PLUMBING CODE
2020 7TH EDITION FLORIDA FUEL GAS CODE
>F 7TH EDITION FLORIDA
EDITIONACCESSIBILITY CODE
FLORIDA * PREVENTION
2017 NATIONAL
AS ADOPTED BY CITY OF ZEPHYRHILLS
PV-1
SITE LOCATION
PV-2
SITE PLAN
PV-2A
ROOF PLAN WITH MODULES LAYOUT
PV-2B
ROOF AND STRUCTURAL TABLES
PV-3
MOUNTING DETAILS
PV-4
THREE LINE DIAGRAM
PV-5
CONDUCTOR CALCULATIONS
PV-6
EQUIPMENT & SERVICE LIST
PV-7
LABELS
PV-7A
SITE PLACARD
PV-8
OPTIMIZER CHART
PV-9
SAFETY PLAN
PV-10
SAFETY PLAN
APPENDIX
MANUFACTURER SPECIFICATION SHEETS
s
DIG ALERT 8 BE D AND - • * •
EXCAVATION TAKING PLACE
PHOTOVOLTAIC SYSTEM GROUND WILL BE TIED fNTO EXISTING GRQ#N*
DISCONNECT/INVERTERDO AS PER k17 AC SEC 250.166(A).
PHOTOVOLTAICSOLAR
REQUIREMENTS OF ART. 690 OF THE 2017 AC
COMPANY
THE MAIN SERVICE PANEL WILL BE EQUIPPED WITH A GROUND ROD OR UFER
UTILITY BE NOTIFIED
..O PRIOR
]U ACTIVATION SOLAR PV SYSTEM
SOLAREDGE OPTIMIZERS ARE LISTED TO IEC 62109-1 (CLASS 11 SAFETY) AND UL 1741 STANDARDS
INSTALL CREW TO VERIFY ROOF STRUCTURE PRIOR TO COMMENCING WORK. EMT CONDUIT
ATTACHED TO THE ROOF USING CONDUIT MOUNT.
6353 BRADFORD WOODS DRIVE,
ZEPHYRHILLS. FL33542
AHJ: CITY OF ZEPHYR-IILLS
UTILITY: DUKE ENERGY (FL)
METER: 82434350
PHONE: (813) 469-5705
EMAIL: VIRIZA9976AOL.COM
FINANCE: SUNRUN
SYSTEM_;
SYSTEM SIZE (DC): 26 X 395 = 10.270 kW
SYSTEM SIZE (AC): 7.600 kW @ 240V
MODULES: 26 X HANWHA OCELL: O.PEAK
DUO L-G5.2 395
OPTIMIZERS: 26 X SOLAREDGE S440
INVERTER: SOLAREDGE SE760OH-USRGM
IS11)
UNHW*010
freedom
FREEDOM_ FOREVER LLC
2619 CONSULATE DR SUITE 800, ORLANDO,
FL 32819
Tel: (800) 385-1075
GREG ALBRIGHT
CC}NT C FOR LICENSE:
CERTIFIED ELECTRICAL CONTRACTOR
EC13008056
SITE LOCATION
JOB N& DATE: DESIGNED BY: I SHEET:
300547 21&t2023 W.K. PV-1
ILEGEND: I
CHIMNEY
PIPE VENT
MODULES
CONDUIT
SETBACK
AC
AC DISCONNECT
JS
JUNCTION BOX
INV
INVERTER
MSP
MAIN SERVICE
PANEL
ROOF PLAN
SCALE 111=10'
NOTE:
TOTAL ROOF AREA: 2749 SQ FT
TOTAL ARRAY AREA: 563.93 SQ FT
ARRAY COVERAGE: 20.51%
ROCKIT SMART SLIDE POINT -LOAD: 25.9
LBS
raft-112M
L Q4
E
Ns',
No. 95019
t
ST TE OF
'0
(ROOF AREA: 2749 SQ FT I
CLIENT:
VICKY IRIZARRY
6353 BRADFORD WOODS DRIVE,
ZEPHYRHILLS, FL 33542
AHJ: CITY OF ZEPHYRHILLS
UTILITY: DUKE ENERGY (FL)
METER: 82434350
PHONE: (813) 46M705
EMAIL: VIRIZA9976@,AOL,COM
FINANCE: SUNRUN
SYSTEM:
SYSTEM SIZE (DC): 26 X 395 = 10270 kW
SYSTEM SIZE (AC): 7.600 kW @ 240V
MODULES: 26 X HANWHA QCELL: Q.PEAK
DUO L-G5.2 395
OPTIMIZERS: 26 X SOLAREDGE S440
INVERTER: SOLAREDGE SE760OH-USRGM
[Sill
24offirem
freedom
P,
FREEDOM FOREVER LLC
2619 CONSULATE DR SUITE 800, ORLANDO,
FL 32819
Tel: (800) 385-1075
2REG ALBRIGHT
CONTRACTOR LICENSE:
CERTIFIED ELECTRICAL CONTRACTOR
EC13008056
1. EMT CONDUIT ATTACHED TO THE ROOF USING CONDUIT MOUNTS
2. ATTACHED CLAMPS AT 25% FROM THE EDGE AND 50% FROM THE CENTER OF THE MODULES
3. JUNCTION BOX IS MOUNTED TO THE RAIL. ROOF PLAN WITH MODULES LAYOUT
JOB NO: DATE� DESIGNED BY: SHEET.
300547 2J,5/2023 WX I PV-2A