HomeMy WebLinkAbout23-5747City of Zephyrhills
5335 Eighth Street
Zephyrhills, FIL 33542
Phone: (813) 780-0020
Fax: (813) 780-0021
BGR-005747-2023
issue Date: 03/01/2023
REINSPECTION FEES: (c) With respect to Reinspection fees will comply with Florida Statute 553.80(2)(c) the
local government shall impose a fee of four times the amount of the fee imposed for the initial inspection or
first reinspection, whichever Is greater, for each subsequent reinspection.
Notice: In addition to the requirements of this permit, there may be additional restrictions applicable to this property that
may be found in the public records of this county, and there may be additional permit required from other governmental
entities such as water management, state agencies or federal agencies.
1.. 0 MEDE�l
Complete Plans, Specifications add fee Must Accompany Application. All work shall be performed in
accordance with City Codes and Ordinances. NO OCCUPANCY BEFORE C.O.
NO OCCUPANCY BEFORE C.O.
fill
CON I RACTOR SIGNATURE PE IT OFFICE
PERMIT EXPIRES IN 6 MONTHS WITHOUT APPROVED INSPECTION
CALL FOR INSPECTION - 8 HOUR NOTICE REQUIRED
PROTECT CARD FROM WEATHER
813-780-0020 City of Zephyrhills Permit Application Fax-ea3-780-0021
Building Department
li:a
ar� wr:rrrr+�rrrrrrr. o�■■�r'�Ji lli��ii�r�ra
Fee Simple Titteholdor Address
SUBDIVISION 1Z-EPWJV_e `,
(OBTAINED FROM PROPERTY TAX NOTICE)
WORK PROPOSED
NEW CONSTR F-1
ADDIALT
SIGN DEMOLISH
El
INSTALL
REPAIR
PROPOSEDUSE
SFR
COMM
OTHER
TYPE OF CONSTRUCTIONaFRAME
DESCRIPTION OF WORK
Installation of a roof -mounted photovoltaic solar panel system.
BUILDING SIZE _ � SQ FOOTAGE HEIGHT
4t4.41111.4.1" ILIE K-aaa�l.tte�64 tc¢iitte4�F.®.tt.tRR.Et�tt�C�t6t. Q.tY.atK.�rl. +t rt�eaa tkatt.
r'�BUILDING VALUATION OF TOTAL CONSTRUCTION
ELECTRICAL $ AMP SERVICE PROGRESS ENERGY W.R.E.0
PLUMBING $
MECHANICAL $ VALUATION OF MECHANICAL INSTALLATION td
GAS ROOFING ® SPECIALTY = OTHER
FINISHED FLOOR ELEVATIONS FLOOD ZONE AREA =YES NO
BUILDERF COMP Sunrun Insta�Fr:rCVRFR��ENY�/N��
Inc'
SIGNATURE REGISTERED Y / N
Address 5280 Tampa W. Blvd, Tampa FL 33634 1 License# �C13007964
ELECTRICIAN COMPANY Fsunrun Installation Services, Inc.
SIGNATURE REGISTERED L_ZIN_j FEE CURREN Y / N
Address 1528OTampa Blvd, Tampa FL 33634 License# =C13007964
PLUMBER COMPANY
SIGNATURE REGISTERED YIN FEE euRREN ;Y;;=
Address License #
MECHANICAL COMPANY
SIGNATURE REGISTERED Y i N FEE CURREN Y l N
Address License #
OTHER COMPANY
SIGNATURE REGSTERED YIN FEE CURREN Y I N
Address License #
!®!!®!!!!!A>ffi!!!t1!!tdl113!!!!!!!!!®!S!•!!!!!!!®!�!®Iflt>fN!!R!!s!!!!!r®!!�
RESIDENTIAL Attach (2) Plot Plans; (2) sets of Building Plans; (1) set of Energy Forms; R-O-W Permit for new construction,
Minimum ten (10) working days after submittal date. Required onsite, Construction Plans, Stormwater Plans w/ Silt Fence installed,
Sanitary Facilities $ 1 dumpster; Site Work Permit for subdivisions/large projects
COMMERCIAL Attach (2) complete sets of Building Plans plus a Life Safety Page; (1) set of Energy Forms. R-O-W Permit for now constriction.
Minimum ten (10) working days after submittal date. Required onsite, Construction Plans, Stormwater Plans w/ Silt Fence installed,
Sanitary Facilities ;3 1 dumpster. Site Work Permit for all new projects. All commercial requirements must meet compliance
SIGN PERMIT Attach (2) sets of Engineered Plans.
—PROPERTY SURVEY required for all NEW construction.
Fill out application completely.
Owner S Contractor sign back of application, notarized
if over $26M, a Notice of Commencement Is required. (A/C Upgrades over $7 )
Agent (for the contractor) or Power of Attorney (for the owner) would be someone with notarized letter from owner authorizing same
OVER THE COUNTER PERMITTING (copy of contract required)
Reroofs if shingles Sewers Service Upgrades A/C Fences (PlottSurvey/F e)
Driveways -Not over Counter if on public roadways..needs ROW
813-7W-0020 City of Zephyrhilis Permit Application Fax-813-780-ID021
Bui ding Department
NOTICE OF DEED RESTRICTIONS: The undersigned understands that this permit may be subject to "deed' restrictions' which may be more restrictive
than County regulations. The undersigned assumes responsibility for compliance with any applicable deed restrictions.
UNLICENSED CONTRACTORS AND CONTRACTOR RESPONSIBILITIES: If the owner has hired a contractor or contractors to undertake work, they
may be required to be licensed In accordance with state and local regulations. If the contractor is not licensed as required by law, both the owner and
contractor may be cited for a misdemeanor violation under state law, If the owner or intended contractor are uncertain as to what licensing requirements
may apply for the intended work, they are advised to contact the Pasco County Building Inspection Division —Licensing Section at 727-847- MM
Furthermore, if the owner has hired a contractor or contractors, he Is advised to have the contractors} sign portions of the 'contractor Block' of this
application for which they will be responsible. If you, as the owner sign as the contractor, that may be an indication that he Is not prop" licensed and is
not entitled to permitting privileges in Pasco County.
TRANSPORTATION IMPACTIUTILITIES IMPACT AND RESOURCE RECOVERY FEES: The undersigned understands
that Transportation Impact Fees and Recourse Recovery Fees may apply to the construction of new buildings, change of use in existing buildings, or
expansion of existing buildings, as specified in Pasco County Ordinance number 89-07 and 90-07, as amended, The undersigned also understands, that
such fees, as may be due, will be identified at the time of peanitting. it is further understood that Transportation Impact Fees and Resource Recovery
Fees must be paid prior to receiving a 'certificate of occupancy' or final power release, If the project does not involve a certificate of occupancy or final
power release, the fees must be paid prior to permit issuance. Furthermore, if Pasco County Water/Sewer Impact fees are due, they must be paid prior
to permit issuance In accordance with applicable Pasco County ordinances.
CONSTRUCTION LIEN LAW (Chapter 713, Florida Statutes, as amended): If valuation of work is $2,5D0.00 or more, I certify that 1, the applicant,
have been provided with a copy of the "Florida Construction Lion Law—Horneowners Protection Guide" prepared by the Florida Department of
Agriculture and Consumer Affairs. If the applicant is someone other than the 'owner', I certify that I have obtained a copy of the above described
document and promise in good faith to deliver It to the "owner' prior to commencement.
CONTRACTOR'SIOWNER'S AFFIDAVIT: I certify that all the information in this application Is accurate and that all work will be done in compliance with
all applicable taws regulating construction, zoning and land development. Application is hereby made to obtain a permit to do work and installation as
indicated. I car* that no work or installation has commenced prior to issuance of a permit and that all work will be performed to meet standards of all
laws regulating construction. County and City codes, zoning regulations, and land development regulations in the jurisdiction. I also certify that I
understand that the regulations of other government agencies may apply to the intended work, and that it is my responsibility to identify what actions I
must take to be in compliance. Such agencies include but are not limited to:
- Department of Environmental Protection -Cypress Bayheads, Wettand Areas and Environmentally Sensitive
Lands, WaterMastewater Treatment.
- Southwest Florida Water Management District -Wells, Cypress Bayheads, Welland Areas, Altering
Watercourses.
Army Corps of Engineers -Seawalls, Docks, Navigable Waterways.
Department of Health & Rehabilitative ServiceslEnvironmental Health Unit -Wells, Wastewater Treatment,
Septic Tanks.
US Environmental Protection Agency -Asbestos abatement,
Federal Aviation Authority -Runways,
I understand that the following restrictions apply to the use of fill:
- Use of fill is not allowed in Flood Zone 'V" unless expressly permitted.
- If the fill material is to be used in Flood Zone 'A", it Is understood that a drainage plan addressing a
"compensating volume" Will be submitted at time of permitting which is prepared by a professional engineer
licensed by the State of Florida.
- If the fill material is to be used in Flood Zone "A" in connection with a permitted building using stem wall
construction, I certify that fill Will be used only to fill the area within the stem wall.
- If fill material is to be used in any area, I certify that use of such fill will not adversely affect adjacent
properties. If use of fill is found to Rdversely affect adjacent properties, the owner may be cited for violating
the conditions of the building permit issued under the attached permit application, for lots less than one (1)
acre which are elevated by fill, an engineered drainage plan is required.
If I am the AGENT FOR THE OWNER, I promise in good faith to inform the owner of the permitting conditions set forth In this affidavit prior to
commencing construction. I understand that a separate permit may be required for electrical work, plumbing, signs, wells, pools, air conditioning, gas, or
other installations not specifically included in the application. A permit issued shall be construed to be a license to proceed with the work and not as
authority to violate, cancel, alter, or set aside any provisions of this technical codes, nor shall issuance of a permit prevent the Building Official from
thereafter requiring a correction of errors in plans, construction or violations of any codes. Every permit issued shall become Invalid unless the work
authorized by such pennit Is commenced within six months of permit issuance, or if work authorized by the permit is suspended or abandoned for a
period of six (6) months after the time the work is commenced, An extension may be requested, in writing, from the Building Official for a period not to
exceed ninety (90) days and will demonstrate justifiable cause for the extension, if work ceases for ninety (90) consecutive days, the job is considered
abandoned.
IPA"AG Ti?ICE FOR liiiPRO'ZF-E-,,'44:r-9---f-'""t�,tR FROPERTill. IF i�01 1ATIE.All TO OElTAIr1,_FwkAAUu;U,
LORIDA JURAT (F3. 117,03)
OWNER -------
AMU&—
CONTRACT.
S b 'bid and me this
S b cn'bed d to (or affirm re, ethis sZbed and s
_b
Who istare pemm rally knovin-fo' a (Orr s/have produced
ho islare perso all known to ritils or has/have produced
identifrcation.
as 'dentlflcation.
Notary Public
—
Commission No, 131qq
0 m.J..... No.
i�q A N �Ss G
qsA.w-
n < t4 t era N�S F N
Name oLf Notary typed, printed or stamped
N me of Notary typed, printed or stamped
ASHLEIGH M, JANSSFN
Notary public, State Of Florida
Commission No, 14H 13090
%Z;eMy Comlois ,$ion Expires: 5/2 1!2025
Astra v.1.765
February 27, 2023
sunr U n WS
CAT 1
Subject : Structural Certification for Proposed Residential Solar Installation.
E W
le
James Matthew , State Flrida,
Job Number: 802R-303WIL1; Rev A
Professional EngiWneealsr,hLicenseof No.o84923
Client: Ricardo Williams
84923
=
This item has been digitally signed and sealed
by James Matthew Walsh, PE on 2/27/2023
Address: 38303 Sonnet Landing Ave, Zephyrhills, FL, 33541
xt
STATE
using a Digital Signature. Printed copies of this
document are not considered signed and sealer
%
00 ID
and the SHA authentication code must be
verified on electronic copies.
Attn: To Whom It May Concern X
A field observation of the existing structure at the address indicated above was performed by a site survey team from Sunrun. Structural
evaluation of the loading was based on the site observations and the design criteria listed below.
Design Criteria:
• 2020 FBC (7th Ed.) AMENDMENTS TO 2018 IRC/IBC/IEBC, 7-16 ASCE & 2018 NDS
Basic Wind Speed V = 138 mph, Exposure C
- Ground Snow Load = 0 psf
Based on this evaluation, I certify that the alteration to the existing structure by the installation of the PV system meets the requirements of the
applicable existing and/or new building code provisions referenced above.
Additionally, I certify that the PV module assembly including all attachments supporting it have been reviewed to be in accordance with the
manufacturer's specifications.
Results ummary (Hardware Check Includes Uplift Chock on Attachmentsl]Fastenor; Structure Chock Considers Main, Structure)
Orientation
Min. #'Mounts per up -slope edge
Configuration
Max OCR'
Result
Landscape
3
NA
65%
Pass,
AR-01
Portrait
3
NA
83%
Pass
Roofing Material
Pitch
Structure Check
Comp Shingle
27'
Pass
Orientation
Min. # Mounts per up -slope edge
Conflouration
Max OCR
Result
Landscape
3
NA
65%
AR-02
Portrait
3
NA
83%
"Pass
Roofing Material
Pitch
Structure Check
Comp Shingle
27'
Pass J
225 Bush St. Suite 1400 San Francisco, CA 94104
.YR
TOP ORMO PV
Warran 0 CELLS
Yield Security
BREAKING THE 20% EFFlCIENCY BARRIER
Q.ANTUM DUO Z Technology with zero gap cell layout
boosts module efficiency up to 21.4%.
THE MOST THOROUGH TESTING PROGRAMME IN THE INDUSTRY
Q CELLS is the first solar module manufacturer to pass the most comprehen-
E=9� sive quality programme in the industry: The new "Quality Controlled IDW of
the independent certification institute TOV Rheinland.
INNOVATIVE ALL-WEATHER TECHNOLOGY
rYz Optimal yields, whatever the weather with excellent
low -light and temperature behavior.
ENDURWG HIGH PERFORMANCE
Long-term yield security with Anti LID Technology, Anti PID
a A Technology', Hot -Spot Protect and Traceable Quality Tra.QTM.
EXTREME WEATHER RATING
High-tech aluminum alloy frame, certified for
high snow (5400 Pa) and wind loads (4000 Pa).
A RELIABLE INVESTMENT
Inclusive 25-year product warranty and 25-year
linear performance warrenty2.
APTteat conditions according to [EC/TS 62804-1:2015, method A (-1500V, 96h)
See data sheet on rear for further information.
THE IDEAL SOLUTION FOR:
69 Rooftop arrays on
residential buildings
Engineered in Germany OCIELLS
MECHANICAL SPECIFICATION
74.0 in - 41.1in - 1.26 in (including frame)
(1879 mm x 1045 mm x 32 mm)
48.5lbs(22,Okg)
0.13in (3.2mm) thermally pre stressed glass with
anti reflection technology
0':
Composite film
Black anodized aluminum
6 x 22 monocrystalline Q, ANTUM solarhalfcells"
2,09-3.98inx1.26-2,36!nx0.59-0.71!n
(53-101mm x 32-60mm x 15-18mm), IP67, with bypass diodes
............
4MM2 Solar cable; (-i) ��49.2in (1260mm), H �t49.21n (1250mm)
.............. .... ........... .. .. ............ ....... .. . ___ ...... . ....
St6ubli MC4; IP68
{zoefi mm)
17,
e
0
(1250 mm)
Err- r85 mmj
ELECTRICAL CHARACTERISTICS
k7m
POWER CLASS
395 400
405
410
415
PMPP IWI 395 400
405
..... .. .
410
415
Isc [A] 11.13 11.16
...
11.19
11,22
11.26
C �il
Vol IV] 45.03 4506
45�09
45.13
....
45,16
..... ...... .
IMPP [A] 10Z8 10.64
1070
10.76
10,82
........ ..
VMPP IV] 37.32 3759
3785
38.11
38.37
q 1%] 20.1 20.4
. .......... . . ..... --- ----- ---- - - ------- . . .... .... ........ ... ------ .. .. ..... . ......... . -- ----
�:20.6
;�20�9
�!21.1
. ............
. .... ......
PMPP IWI 2964 300.1
..........
303.9
3076
311.4
sc [A] 8.97 8.99
9.02
9.04
9.07
VOC IV] 4246 4249
42�52
... ... .......
42.56
...... .... .
4259
[A] 833 8.38
8.43
8.48
853
V, 35,82
MPP IV] 35,59
3 6.04
36.27
36.49
'Measurement tolerances P.- 3%; 1,c; V
±5% at STC: 1000W/m2, 25±2°C, AM 1.5 according to IEC 60904-3,2800W/M2,
NMOT, spectrum AM 1.5
Q CELLS PERFORMANCE WARRANTY
PERFORMANCE AT LOW IRRADIANCE
At!east 98% of nominal power during lac
first year. Thereafter max. 0.5%
------------------
degradation per year. At least 93.5%
of nominal power up to 10 years, At
least 86% of nominal power up to
25 years.
-------------------
All data within measurement toleranc-
es, Full warranties in accordance with
zoo
Soo Soo W.0
the warranty terms of the Q CELLS
sales organisation of your respective
1 A, I
country.
Typical module performance under low irradiance conditions in
comparison to STC conditions
(25'C, 100OW/m2)
TEMPERATURE COEFFICIENTS
a [%/K] +0,04
[%/K]
0.27
y [%/K] -0.34
NMOT
['Fl
109±5.4 (43±3'C)
Note: Installation instructions must be followed. See the installation and operating manual or contact our technical service department for further information on approved installation and use of
this product.
Hanwha 0 CELLS America Inc.
400 Spectrum Center Drive, Suite 1400, Irvine, CA 92618, USA I TEL +1949 748 59 96 1 EMAIL nquiry@us.c-cellsoom I WES www.q-cells.us
SHEETINDEX
LEGEND
SCOPE OF WORK
GENERAL NOTES
PAGE #
DESCRIPTION
® SYSTEM SIZE: 920OW DC, 760OW AC
ALL WORK SHALL COMPLY WITH 2O20 FBC (7TH ED.) AMENDMENTS TO 2018
PV_1.0
COVER SHEET
SE
SERVICE ENTRANCE
- MODULES: (23) HANWHA Q-CELLS: Q.PEAK DUO BLK
IRC(IBC/IEBC, MUNICIPAL CODE, AND ALL MANUFACTURERS` LISTINGS AND
ML-G10+ 400
INSTALLATION INSTRUCTIONS,
PV-2.O
SITE FLAN
- INVERTERS: (1) SOLAREDGE TECHNOLOGIES:
m PHOTOVOLTAIC SYSTEM WILL COMPLY WITH NEC 2017.
MP
MAIN PANEL
SE760OH-USSN
PV-3.0
LAYOUT
s RACKING: TOPSPEED, SEE DETAIL SNR-DC--30004
® ELECTRICAL SYSTEM GROUNDING WILL COMPLY WITH NEC 2017.
PV-4.O
ELECTRICAL
SP
SUB -PANEL
- PHOTOVOLTAIC SYSTEM IS UNGROUNDED. NO CONDUCTORS ARE SOLIDLY
PV-5.0
SIGNAGE
—
GROUNDED IN THE INVERTER, SYSTEM COMPLIES WITH 690.35.
LC
PV LOAD CENTER
- MODULES CONFORM TO AND ARE LISTED UNDER UL 1703.
a INVERTER CONFORMS TO AND IS LISTED UNDER UL 1741.
SM
I
SUNRUN METER
RACKING CONFORMS TO AND IS LISTED UNDER UL 2703.
PM
DEDICATED PV METER
® SNAPNRACK RACKING SYSTEMS, IN COMBINATION WITH TYPE I, OR TYPE II
MODULES, ARE CLASS A FIRE. RATED.
4NV
INVERTER(S)
m RAPID SHUTDOWN REQUIREMENTS MET WHEN INVERTERS AND ALL
�q�1Ett€!!!f tll
A. V/�`'
CONDUCTORS ARE WITHIN ARRAY BOUNDARIES PER NEC 690.12(1).
AC
r Clt�
AC DISCONNECT(S)
e CONSTRUCTION FOREMAN TO PLACE CONDUIT RUN PER 690.31(G).
No. g5111 "
DC
DC DISCONNECT
m ARRAY DC CONDUCTORS ARE SIZED FOR DERATED CURRENT,
r s
TS) y S ATE OF-
11.14 AMPS MODULE SHORT CIRCUIT CURRENT.
'/()NA�_�s�
CB
IQ COMBINER BOX
a 17.4 AMPS DERATED SHORT CIRCUIT CURRENT [690.3 (A) & 690.8 (B)).
ABBREVIATIONS
�i
INTERIOR EQUIPMENT
SIGNED:EXPIRES:2/24/22023
A
AMPERE
L
SHOWN AS DASHED
AC
ALTERNATING CURRENT
AFC
ARC FAULT CIRCUIT INTERUPTER
,,._....,....
CHIMNEY
sunrun
AZIM
AZIMUTH
ENGINEER ADDRESS:
225 BUSH 5T, SUITE 5406
COMP
COMPOSITIONSAN
FRANCISCO. CA 94104
P: 949-383-0993
DC
DIRECT CURRENT
ATTIC VENT
EC13007964
VICINITY MAP
(E)
EXISTING
FLUSH ATTIC VENT
ESS
ENERGY STORAGE SYSTEM
PVC PIPE VENT5208
; l.;
iAMPA W BLVC, TAlv4PA, FL 33834
PHON
EAx0e9
EXT
EXTERIOR
METAL PIPE VENT
CUSTOMER RESIDENCE:
INT
INTERIOR
T-VENT
RICARDO WILLIAMS
MSP
MAIN SERVICE PANEL
38303 SONNET LANDING AVE,
(N)
NEW
ZEPHYRHILLS, FL, 33541
SATELLITE DISH
NTS
NOT TO SCALE
-
TEL. (727) 389-5679
GO
ON CENTER
„
FIRE SETBACKS
APN:
PRE-FAB
PRE -FABRICATED
- `
PROJECT NUMBER:
PSF
POUNDS PER SQUARE FOOT
I
4
HARDSCAPE
,.
602R-303WIL1
PV
PHOTOVOLTAIC
?
DESIGNER: (495) 550-6920 ex3
RSD
RAPID SHUTDOWN DEVICE
— PL--
PROPERTY LINE
°
DAVE RYAN
TL
TRANSFO€zMERLESS
=
SOLAR MODULES
SCALE: NTS
,
91
SHEET
TYP
TYPICAL
f*--
REV NAME DATE COMMENTSCOVER
SHEET
V
VOLTS
I
" €
W
WATTS
REV: A 2124/2023
LAN
LANDSCAPE
-
TC7P5PEED
PAGE
MOUNT
�g� r®i
bi
POP
PORTRAIT
t'" e
Template version_4.0.87
MY
��
r t
t
rAREA
r
Y•
Y
ROOF INFO
FRAMING INFO
ATTACHMENT INFORMATION
DESIGN CRITERIA
Name
Type
Height
Type
Max
OC
Detail
Minimum Nuumber of Mounts per
Max Landscape
Max Portrait MAX DISTRIBUTED LOAD: 3 PSF
Span
Spacing
Up -Slope Edge
Overhang
Overhang SNOW LOAD: 0 PSF
AR-01
COMP SHINGLE -
TOPSPEED
1-Story
2X4 PRE -FABRICATED TRUSSES
6'- 7"
24"
TOPSPEED, SEE DETAIL SNR-DC-30004
3
1'- 6"
WIND SPEED:
01 - 10" 138 MPH 3-SEC GUST.
S.S. LAG SCREW
AR-02
COMP SHINGLE -
TOPSPEED
1-Story
2X4 PRE -FABRICATED TRUSSES
6'- 7"
24"
TOPSPEED, SEE DETAIL SNR-DC-30004
3
1'- 6"
01-101, (4) #14 X 225" SS SEALING
I
WASHER WOOD SCREWS FULLY
PENETRATING THROUGH WOOD
131 - AR-01 - SCALE: 1/8" = V-0"
26'-8"
DECK
AZIM: 91'
12'-5"__i 22'-11
PITCH: 27'
14 E W
ENS
23 %
-0 t4
,'TATE OF
A
0.
tORID
e
X
LI
2/27/2023
e E) E) e
20'-5"-
24'-10"-- -16-8"-11
I
1'2"
D2 - AR-02 - SCALE: 1/8" = V-0"
AZIM: 181'
Ar-
u nf"u
PITCH: 27'
kbo
ENGINEER ADDRESS:
INSTALLERS SHALL NOTIFY ENGINEER OF ANY
EE
225 BUSH ST, SUITE 1400
SAN FRANCI83-0993SCO, CA 94104
P 949-3
POTENTIAL STRUCTURAL ISSUES OBSERVED
EC13007964
PRIOR TO PROCEEDING W/ INSTALLATION.
- MOUNT NUMBER FOR LEADING DOWNSLOPE
5208 TAMPA W BLVD, TAMPA, FL 33634
PHONED
EDGE SHALL MATCH REQUIREMENTS LISTED
FAX 0
ABOVE INSTALL PER TOPSPEEDTM
INSTALLATION MANUAL.
- - -
CUSTOMER RESIDENCE:
- CONTRACTOR MAY SUBSTITUTE SNAPNRACK
RICARDO WILLIAMS
DECKTRACK MOUNTS (SNR DETAIL
38303 SONNET LANDING AVE,
SNR-DC-00453) WITH A MAX OVERHANG OF 6"
ZEPHYRHILLS, FL, 33541
10, -51,
TEL. (727) 389-5679
APN:
PROJECT NUMBER:
e e e
802R-303WIL1
3'-6"
DESIGNER: (415) 580-6920 ex3
DAVE RYAN
6'-5"
o
12'-5" T-T'
SHEET
LAYOUT
REV: A1 2/25/2023
PAGE PV-3.0
120/240 VAC
SINGLE PHASE
SERVICE
METER#:
NOTE. TOTAL PV BACKFEED = 40A
<--
DUKE ENERGY 3839665 USED FOR INTERCONNECTION
UTILITY
CALCULATIONS
GRID
EXISTING 150A
MAIN BREAKER
(END FED)
EXISTING 200A
EXISTING 225A
MAIN PANEL
SUB PANEL
200 A
(N) LOCKABLE
SOLAREDGE TECHNOLOGIES:
FACILITY
MAIN BUS
BLADE TYPE
SE760OH-USSN
LOADS
AC DISCONNECT
7600 WATT INVERTER
JUNCTION BOX
PV MODULES
,E)
3,31
R EQUIVALENT
HANWHA Q-CELLS: Q.PEAK DUO BLK
FEED -THROUGH
A✓
ML-G10+ 400
LUG
0
(23) MODULES
OPTIMIZERS WIRED IN:
-cl fry
(1) SERIES OF (12) OPTIMIZERS
1GROUND
(N) 40A PV SQUARE D
LOAD RATED DC DISCONNECT
(1) SERIES OF (11) OPTIMIZERS
BREAKER AT DU222RB
WITH AFCI, RAPID SHUTDOWN
SOLAREDGE POWER OPTIMIZERS
OPPOSITE END 3R, 60A,2P
COMPLIANT
P401
OF BUSBAR 120/240VAC
CONDUIT SCHEDULE
#
CONDUIT
CONDUCTOR
NEUTRAL
GROUND
NONE
(4) 10 AWG PV WIRE
NONE
(1) 6 AWG BARE COPPER
2
3/4" EMT OR EQUIV,
(4) 10 AWG THHN/THWN-2
NONE
(1) 8 AWG THHN/THWN-2
3
3/4" EMT OR EQUIV.
(2) 8 AWG THHN/THWN-2
(1) 10 AWG THHN/THWN-2
(1) 8 AWG THHN/THWN-2
E
EXISTING
EXISTING
EXISTING
EXISTING
MODULE CHARACTERISTICS
HANWHA Q-CELLS: Q,PEAK DUO ELK
P401 OPTIMIZER CHARACTERISTICS:
ML-Gl 0+ 400-1
400 W
MIN INPUT VOLTAGE:
8 VDC
OPEN CIRCUIT VOLTAGE.-
45 3 V
MAX INPUT VOLTAGE:
60 VDC
MAX POWER VOLTAGE:
37 13 V
MAX INPUT ISC:
11.75 ADC
SHORT CIRCUIT CURRENT:
11. 14 A
MAX OUTPUT CURRENT
15 ADC
SYSTEM CHARACTERISTICS -INVERTER I
SYSTEM SIZE:
9200 W
SYSTEM OPEN CIRCUIT VOLTAGE-
12 V
SYSTEM OPERATING VOLTAGE:
400 V
MAX ALLOWABLE DC VOLTAGE:
480 V
SYSTEM OPERATING CURRENT:
23 A
SYSTEM SHORT CIRCUIT CURRENT:
30 A
f) A V1
No, 85111
STATE OF
o P,
///////O/ONAL
fl/1111111WOO
EXPIRES: 2/28/2025
SIGNED: 02/24/2023
Template—varsion-4.0,87
ELECTRICAL SHOCK HAZARD
DO NOT RELOCATE THIS
OVERCURRIENT DEVICE
LABEL LOCATION:
ADJACENT TO PV BREAKER (IF
APPLICABLE).
PER CODE(S): NEC 2017:
705.12(B)(2)(3)(b)
LABEL LOCATION:
PHOTOVOLTAIC AC COMBINER (IF
APPLICABLE),
PER CODE(S): NEC 2017: 705.12(13)(2)(3)(c)
POWERDUAL
SOURCES: UTILITY GRID
SOU [
.:D " OL R ELECTRIC
SYST
SYSTEM
LABEL LOCATION:
UTILITY SERVICE METER AND MAIN
SERVICE PANEL.
PER CODE(S): NEC 2017: 705.12(B)(3)
LABEL LOCATION:
INSTALLED WITHIN T OF RAPID SHUT DOWN
SWITCH PER CODE(S): NEC 2017: 690.56(C)(3), IFC
2012: 605.11.1, IFC 2018: 1204.5.3
LABEL LOCATION:
INTERIOR AND EXTERIOR DC CONDUIT EVERY 10 FT,
AT EACH TURN, ABOVE AND BELOW PENETRATIONS,
ON EVERY JBIPULL BOX CONTAINING DC CIRCUITS.
PER CODE(S): NEC 2017: 690.31(G)(3), 690.31(G)(4),
IFC 2012: 605A 1.1.4
LABEL LOCATION:
AC DISCONNECT(S), PHOTOVOLTAIC SYSTEM POINT OF INTERCONNECTION.
PER CODE(S): CEC 2019: 690.54, NEC 2017: 690.54, NEC 2014: 690.54, NEC
2011: 690.54
LABEL LOCATION:
INVE.RTER(S), DC DISCONNECT(S).
PER CODE(S): CEC 2019: 690.53, NEC 2017: 690.53
IN
TURN RAPID SHUTDOWN
HAZARDSWITCH TO THE "OFF"
POSITION TO SHUT DOWN
PV SYSTEM AND REDUCE
SHOCK
IN THE
LABEL LOCATION:
ON OR NO MORE THAT 1 M (3 FT) FROM THE SERVICE
DISCONNECTING MEANS TO WHICH THE PV SYSTEMS
ARE CONNECTED,
PER CODE(S): NEC 2017: 690.56(C)(1)(a)
NOTES AND SPECIFICATIONS:
* SIGNS AND LABELS SHALL MEET THE REQUIREMENTS OF THE NEC 2017 ARTICLE
110.21(B), UNLESS SPECIFIC INSTRUCTIONS ARE REQUIRED BY SECTION 690, OR
IF REQUESTED BY THE LOCAL AHJ.
* SIGNS AND LABELS SHALL ADEQUATELY WARN OF HAZARDS USING EFFECTIVE
WORDS, COLORS AND SYMBOLS.
* LABELS SHALL BE PERMANENTLY AFFIXED TO THE EQUIPMENT OR WIRING
METHOD AND SHALL NOT BE HAND WRITTEN.
* LABEL SHALL BE OF SUFFICIENT DURABILITY TO WITHSTAND THE ENVIRONMENT
INVOLVED.
* SIGNS AND LABELS SHALL COMPLY WITH ANSI Z535.4-2011, PRODUCT SAFETY
SIGNS AND LABELS, UNLESS OTHERWISE SPECIFIED.
* DO NOT COVER EXISTING MANUFACTURER LABELS.
tttttlrrrrrrr r/1
A.
No. 85111
a s $
8 S w
STATE OF {� 4
////r'9/ONAL
EXPIRES: 2/2812025
SIGNED: 02/24/2023
1-1— „ape.— An P7
SHEETINDEX
LEGEND
SCOPE OF WORK
GENERAL NOTES
DE RIPTIO
m SYSTEM SIZE.: 920OW DC, 760OW AC
® ALL WORK SHALL COMPLY WITH 2O20 FBC (7TH ED.) AMENDMENTS TO 2018
rPPA:G:E#
V-1.0
COVER SHEET
SE
SERVICE ENTRANCE
- MODULES: (23) HANWHA Q-CELLS: Q.PEAK DUO BLK
IRC/IBC/IEBC, MUNICIPAL CODE, AND ALL MANUFACTURERS' LISTINGS AND
ML-G10+ 400
INSTALLATION INSTRUCTIONS,
PV-2.0
SITE PLAN
® INVERTERS: (1) SOLAREDGE TECHNOLOGIES:
® PHOTOVOLTAIC SYSTEM WILL COMPLY WITH NEC 2017.
El
MAIN PANEL
SE760OH-USSN
PV-3.0
LAYOUT
d RACKING: TOPSPEED, SEE DETAIL SNR-DC-30004
< ELECTRICAL SYSTEM GROUNDING WILL COMPLY WITH NEC 2017.
PV-4.0
ELECTRICAL
ASP
L
SUS -PANEL
PHOTOVOLTAIC SYSTEM IS UNGROUNDED. NO CONDUCTORS ARE SOLIDLY
PV-5.0
SIGNAGE
-�
GROUNDED IN THE INVERTER. SYSTEM COMPLIES WITH 690.35.
LC
PV LOAD CENTER
MODULES CONFORM TO AND ARE LISTED UNDER UL 1703.
® INVERTER CONFORMS TO AND IS LISTED UNDER UL 1741.
SM
SUNRUN METER
RACKING CONFORMS TO AND IS LISTED UNDER UL 2703.
PM
DEDICATED PV METER
® SNAPNRACK RACKING SYSTEMS, IN COMBINATION WITH TYPE I, OR TYPE li
MODULES, ARE CLASS A FIRE RATED,
[INV]
INVERTER(S)
RAPID SHUTDOWN REQUIREMENTS MET WHEN INVERTERS AND ALL
,,,}tti4�tlf!
t�t```�� A, Vll�''�P,,,
CONDUCTORS ARE WITHIN ARRAY BOUNDARIES PER NEC 690A2(1),
ENs,
AC
�
AC DISCONNECT(S)
- CONSTRUCTION FOREMAN TO PLACE CONDUIT RUN PER 690.31(G).
4 � g p�q
DC
DC DISCONNECT(S)
- ARRAY DC CONDUCTORS ARE SIZED FOR DEBATED CURRENT.
e 4
}� S T A.TE JEE1F
CURRENT.
® 11.14 AMPS MODULE SHORT CIRCUIT
CB
IQ COMBINER BOX
® 17.4 AMPS DEBATED SHORT CIRCUIT CURRENT [690.8 (A) & 690.8 (B)}.
ABBREVIATIONSINTERIOR
EXPIRE& 2/28/2025
SIGNED: 02/24/2023
EQUIPMENT
A
AMPERE
L
SHOWN AS DASHED
AC
ALTERNATING CURRENT
AFC
ARC FAULT CIRCUIT INTERUPTER
CHIMNEY
sunrun
AZIM
AZIMUTH
�
ENGINEER ADDRESS:
225 BUSH ST, SUITE 1400
COMP
COMPOSITION
FR
Rai 9383-09S3o, GA 94104
DC
DIRECT CURRENT
ATTIC VENT
EC13007964
VICINITY
EEp
EXISTING
FLUSH ATTIC VENT
52081AMPA W BIND, TAMPA. FL33634
ESS
ENERGY STORAGE SYSTEM
PVC PIPE VENT
�� � f, �'
F'Hf7NE. 6
FAX q
EXT
EXTERIOR
METAL PIPE VENT
CUSTOMER RESIDENCE:
INT
INTERIOR
RICARDO WILLIAMS
MSP
MAIN SERVICE PANEL
T-VENT
38303 SONNET LANDING AVE,
�N>
NEW
ZEPHYRHILLS, FL, 33541
SATELLITE DISH
NTS
NOT TOSCALE
TEL. (727) 389-5679
OC
ON CENTER
FIRE SETBACKS
AF'N:
PRE-FAB
PRE -FABRICATES
_
PROJECT NUMBER:
PSF
POUNDS PER SQUARE FOOT
'~
HABDSCAPE
802R-303WIL1
PV
PHOTOVOLTAIC
DESIGNER: (415} 58Q-692Q eX3
RED
RAPID SHUTDOWN DEVICE
— PL--
PROPERTY LINE
DAVE RYAN
TL
TRANSFORMERLESS
�
SOLAR MODULES
SCALE: NTS
SHEET
TYP
TYPICAL
3
I
..
REV NAME DATE COMMENTS
EF SHEET
V
VOLTS
I
W
WATTS"Fz"-+.'-s-'
:'
REV: A 2/24/2023
LAN
LANDSCAPE
;_,.._.__,
TOPSPEECi
MOUNT
PAGE
POR
PORTRAIT
.
r`emptaPe_version_4.0, 87
120/240 VAC
SINGLE PHASE
SERVICE
METER#:
NOTE: TOTAL PV BACKFEED = 40A
um
DUKE ENERGY 3839665 USED FOR INTERCONNECTION
CALCULATIONS
UTILITY
GRID
EXISTING 150A
MAIN BREAKER
(END FED)
EXISTING 200A
EXISTING 225A
MAIN PANEL
SUB PANEL
(N) LOCKABLE
200 A
BLADE TYPE
FACILITY
MAIN BUS
AC DISCONNECT
LOADS
FEED -THROUGH
LUG
FACl! J-
4V,GROUND
(N) 40A PV
SQUARE D
BREAKER AT
DU222RB
OPPOSITE END
3R, 60A,2P
OF BUSBAR
120/240VAC
SOLAREDGE TECHNOLOGIES:
SE760OH-USSN
7600 WATT INVERTER
�7-
v
LOAD RATED DC DISCONNECT
WITH AFCI, RAPID SHUTDOWN
COMPLIANT
CONDUIT SCHEDULE
#
CONDUIT
CONDUCTOR
NEUTRAL
GROUND
I
NONE
(4) 10 AWG PV WIRE
NONE
(1) 6 AWG BARE COPPER
2
3/4" EMT OR EQUIV.
(4) 10 AWG THHN/THWN-2
NONE
(1) 8 AWG THHN/THWN-2
3
3/4" EMT OR EQUIV.
(2) 8 AWG THHN/THWN-2
(1) 10 AWG THHN/THWN-2
(1) 8 AWG THHN/THWN-2
I
E
i
EXISTING
EXISTING
EXISTING
�IS T I N �G
EXISTING
MODULE CHARACTERISTICS
P401 OPTIMIZER CHARACTERISTICS:
HANWHA Q-CELLS: Q.PEAK DUO BLK
MIN INPUT VOLTAGE:
8 VDIC
ML-GlO+ 400-
400 w
MAX INPUT VOLTAGE:
60 VDC
I
OPEN CIRCUIT VOLTAGE:
45.3 V
MAX INPUT ISC:
lt75A
MAX POWER VOLTAGE:
37,13 V
MAX OUTPUT CURRENT:
15 ADC
SHORT CIRCUIT CURRENT:
11,14 A
SYSTEM CHARACTERISTICS - INVERTER I
SYSTEM SIZE:
9200 W
SYSTEM OPEN CIRCUIT VOLTAGE:
12 V
SYSTEM OPERATING VOLTAGE:
400 V
MAX ALLOWABLE DO VOLTAGE:
480 V
SYSTEM OPERATING CURRENT:
23 A
SYSTEM SHORT CIRCUIT CURRENT:
30 A
JUNCTION BOX PV MODULES
OR EQUIVAL NT HANWHA Q-CELLS: Q.PEAK DUO BLK
M L-G 10+ 400
- ----- (23) MODULES
OPTIMIZERS WIRED IN:
�(1) SERIES OF (12) OPTIMIZERS
(1) SERIES OF (11) OPTIMIZERS
SOLAREDGE POWER OPTIMIZERS
P401
A.
No. 85111
STATE OF
0 o 9,
s
///o/0NAk_
/0011IM000
EXPIRES: 2/28/2025
SIGNED: 02/24/2023
Template—version-4. 0, 87
ELECTRICAL SHOCK HAZARD
r
LABEL LOCATION:
ffisM�iMmmi ON".
POWER SOURCE OUTPUT CONNECTION
LABEL LOCATION:
ADJACENT TO PV BREAKER (IF
APPLICABLE).
PER CODE(S): NEC 2017:
705.12(B)(2)(3)(b)
LABEL LOCATION:
PHOTOVOLTAIC AC COMBINER (IF
APPLICABLE).
PER CODE(S): NEC 2017: 705.12(B)(2)(3)(e)
DUAL POWER SUPPLY
SOURCES: UTILITY GRID
z # t 71 k&-i I,
SYSTEM
LABEL LOCATION:
UTILITY SERVICE METER AND MAIN
SERVICE PANEL.
PER CODE(S): NEC 2017: 705.12(B)(3)
LABEL LOCATION:
INSTALLED WITHIN 3" OF RAPID SHUT DOWN
SWITCH PER CODE(S): NEC 2017: 690.56(C)(3), IFC
2012: 605.11.1, IFC 2018: 1204.5.3
LABEL LOCATION:
INTERIOR AND EXTERIOR DC CONDUIT EVERY 10 FT,
AT EACH TURN, ABOVE AND BELOW PENETRATIONS,
ON EVERY JB/PULL BOX CONTAINING DC CIRCUITS.
PER CODE(S): NEC 2017: 690.31(G)(3), 690 31(G)(4),
IFC 2012: 605.11.1.4
LABEL LOCATION:
AC DISCONNECT(S), PHOTOVOLTAIC SYSTEM POINT OF INTERCONNECTION.
PER CODE(S): CEC 2019: 690.54, NEC 2017: 690.54, NEC 2014: 690.54, NEC
2011: 690.54
IN
mmulsillm
LABEL LOCATION:
INVERTER(S), DO DISCONNECT(S),
PER CODE(S): CEC 2019: 690.53, NEC 2017: 690.53
a
SHOCK HAZARD IN THE
LABEL LOCATION:
ON OR NO MORE THAT 1 M (3 FT) FROM THE SERVICE
DISCONNECTING MEANS TO WHICH THE PV SYSTEMS
ARE CONNECTED.
PER CODE(S): NEC 2017: 690.56(C)(1)(a)
NOTES AND SPECIFICATIONS:
• SIGNS AND LABELS SHALL MEET THE REQUIREMENTS OF THE NEC 2017 ARTICLE
110.21(B), UNLESS SPECIFIC INSTRUCTIONS ARE REQUIRED BY SECTION 690, OR
IF REQUESTED BY THE LOCAL AHJ.
• SIGNS AND LABELS SHALL ADEQUATELY WARN OF HAZARDS USING EFFECTIVE
WORDS, COLORS AND SYMBOLS.
• LABELS SHALL BE PERMANENTLY AFFIXED TO THE EQUIPMENT OR WIRING
METHOD AND SHALL NOT BE HAND WRITTEN.
• LABEL SHALL BE OF SUFFICIENT DURABILITY TO WITHSTAND THE ENVIRONMENT
INVOLVED.
• SIGNS AND LABELS SHALL COMPLY WITH ANSI Z535.4-2011, PRODUCT SAFETY
SIGNS AND LABELS, UNLESS OTHERWISE SPECIFIED.
• DO NOT COVER EXISTING MANUFACTURER LABELS.
1�ft4ttt4itt'k/t Jk�r/
No.85111
e x
a STATE OF
IZ-
j0/1 U A i \k ` �
EXPIRES: 2/28/2025
SIGNED: 02/24/2023
Tampkatr- version 4.0.87