HomeMy WebLinkAbout23-5749City of Zephyrhills UP
5335 Eighth Street
Zephyrhills, FL 33542 ELCMISC-005749-2023
Phone: (813) 780-0020 Fax: (813) 780-0021 Issue Date: 03/02/2023
REINSPECTION FEES: (c) With respect to Reinspection fees will comply with Florida Statute 553.80(2)(c) the
local government shall impose a fee of four times the amount of the fee imposed for the initial inspection or
first reinspection, whichever is greater, for each subsequent reinspection.
Notice: In addition to the requirements of this permit, there may be additional restrictions applicable to this property that
may be found in the public records of this county, and there may be additional permit required from other governmental
entities such as water management, state agencies or federal agencies,
Complete Plans, Specifications add fee Must Accompany Application. All work shall be performed in
accordance with City Codes and Ordinances. NO OCCUPANCY BEFORE C.O.
NO OCCUPANCY BEFORE C.O.
7,NTRACTOR SIGNATURE
T E IT X
1T EXPIRES IN 6 MONTHS
813.780-0020 City of Zephyrhills Permit Application Fax-e13-780-0021
Building Department
Driveways -Not over Counter if on public roadways..needs ROW
813-7$0-0020 City of Zephyrhills Permit Application Fax-813-780-0021
But ding Department
NOTICE OF DEED RESTRICTIONS: The undersigned understands that this permit maybe subject to "deed" restrictions' which maybe more restrictive
than County regulations. The undersigned assumes responsibility for compliance with any applicable deed restrictions.
UNLICENSED CONTRACTORS AND CONTRACTOR RESPONSIBILITIES: N the owner has hired a contractor or contractors to undertake work, they
may be required to be licensed In accordance with state and local regulations. If the contractor is not licensed as required by law, both the owner and
contractor may be cited for a misdemeanor violation under state law. If the owner or intended contractor are uncertain as to what licensing requirements
may apply for the Intended work, they are advised to contact the Pasco County Building Inspection Divislon--l-loonsing Section at 727-847- 8009.
Furthermore, if the owner has hired a contractor or contractors, he is advised to have the oontractor(s) sign portions ofthe "contractor Block" ofthis
application for which they will be responsible. If you, as the owner sign as the contractor, that may be an Indication that he Is not properly licensed and is
not entitled to permitting privileges In Pasco County.
TRANSPORTATION IMPACT/UTILrrIES IMPACT AND RESOURCE RECOVERY FEES: The undersigned understands
that Transportation Impact Fees and Recourse Recovery Fees may apply to the construction of new buildings, change of use in existing buildings, or
expansion of existing buildings, as specified In Pasco County Ordinance number 89-07 and 90-07, as amended, The undersigned also understands, that
such fees, as may be due, will be identified at the fte of permitting. It is further understood that Transportation Impact Fees and Resource Recovery
Fees must be paid prior to receiving a "certificate of occupancy' or final power release. If the project does not involve a certificate of occupancy or final
power release, the fees must be paid prior to permit Issuance. Furthermore, if Pasco County Water/Sewer Impact fees are due, they must be paid prior
to permit issuance In accordance with applicable Pasco County ordinances.
CONSTRUCTION LIEN LAW (Chapter 713, Florida Statutes, as amended): If valuation of work is $2,500.00 or more, I cer* that 1, the applicant,
have been provided with a copy of the 'Florida Construction Lien Law —Homeowner's Protection Guide" prepared by the Florida Department of
Agriculture and Consumer Affairs. If the applicant is someone other than the 'owner, I certify that I have obtained a copy of the above described
document and promise in good faith to deliver it to the 'owner' prior to commencement.
CONTRACTOWSIOWNER'S AFFIDAVIT: I certify that all the Information In this application is accurate and that all work will be done in compliance with
all applicable lam regulating construction, zoning and land development, Application is hereby made to obtain a permit to do work and installation as
indicated. I certify that no work or installation has commenced prior to issuance of a permit and that all work will be performed to meet Standards of all
laws regulating construction, County and City codes, zoning regulations, and land development regulations in the jurisdiction. I also certify that I
understand that the regulations of other government agencies may apply to the intended work, and that it is my responsibility to identify what actions I
must take to be in compliance. Such agencies include but are not limited to:
- Department of Environmental Protection -Cypress Bayheads, Welland Areas and Environmentally Sensitive
Lands, Water/Wastewater Treatment.
- Southwest Florida Water Management District -Wells, Cypress Bayheads, Wetland Areas, Altering
Watercourses.
- Army Corps of Engineers -Seawalls, Docks, Navigable Waterways.
- Department of Health & Rehabilitative Services/Environmental Health Unit -Wells, Wastewater Treatment,
Septic Tanks.
- US Environmental Protection Agency -Asbestos abatement.
- Federal Aviation Authority -Runways.
I understand that the following restrictions apply to the use of fill:
- Use of fill is not allowed in Flood Zone -V" unless expressly permitted.
- If the fill material is to be used in Flood Zone 'A", it is understood that a drainage plan addressing a
.compensating volume" Will be submitted at time of permitting which is prepared by a professional engineer
licensed by the State of Florida.
- If the fill material is to be used in Flood Zone "A" in connection with a permitted building using stem wall
construction, I certify that fill will be used only to fill the area within the stem wall.
- If fill material is to be used in any area, I certify that use of such fill will not adversely affect adjacent
properties. If use of fill is found to adversely affect adjacent properties, the owner may be cited for violating
the conditions of the building permit issued under the attached permit application, for lots less than one (1)
acre which are elevated by fill, an engineered drainage plan is required.
If I am the AGENT FOR THE OWNER, I promise in good faith to inform the owner of the permitting conditions set forth in this affidavit prior to
commencing construction. I understand that a separate permit may be required for electrical work, plumbing, signs, wells, pools, air conditioning, gas, or
other Installations not specifically included in the application. A permit issued shall be construed to be a license to proceed with the work and not as
authority to violate, cancel, after, or set aside any provisions of the technical codes, nor shall issuance of a permit prevent the Building Official from
thereafter requiring a correction of errors in plans, construction or violations of any codes. Every permit issued shall become Invalid unless the work
authorized by such permit Is commenced within six months of permit issuance, or K work authorized by the permit is suspended or abandoned for a
period of six (6) months after the time the work is commenced. An extension may be requested, in writing, from the Building Official for a period not to
exceed ninety (90) days and will demonstrate justifiable cause for the extension. If work ceases for ninety (90) consecutive days, the job is considered
abandoned.
W-VIII 11Z Lem 111T,11M Z1 101 1.4 1 Ji W 114YA -;, 4 11 A: IfIRS ilowilol I K a zJ ;A $1,124 ;J WA I'ML91,11 I I Z It 4 :1011111 0LOQ--]
OWNER OR AGENT CONTRACTOR
Subscribed and swgm to k before me this Subscribad and Vsync LI to (of'?ffirmed) before me this
JIAby , C 3LU &, _ jg b,
Ott
Who Is1are_p!T9rk Who is/are personally known to me or has/have produced
aQxkamwLto=aoifiaaiave produced
as identification. as !dentification.
&A61uj Or . Ah"9A__ Notary Public alern,_Notary Pu
on ZN
Commission Commission No. 414 'J'C U,2
b
tm oa typed, �Nolry ly �®rint.d or Na a o No ary ad, tinted or stamped
R
XBRITTANY L. DEBOINER
1.Cww*Ww#HH269W
E)#w Wa1. 2026
�t�v y
BRITTANY L. DEBOUVER
I*, a p<CommissM # HH 2694N
-Z Expires May 1, 2026
Astral v.1,765
sunrun
February 23, 2023
WS
CAT 1
Subject : Structural Certification for Proposed Residential Solar Installation.
\\\�,<j VA E W / James Matthew Walsh, State of Florida,
PV /
Job Number: 802R-414DRAY; Rev A
Professional Engineer, License No. 84923
4V
Client: Damien Drayton
Address: 8414 Wheat Stone Dr, Zephyrhills, FL, 33540
11
r* I , '1 � - I This item has been digitally signed and sealed
J�7o
A� by James Matthew Walsh, PE on 2/23/2023
'44*W A* wo,
using a Digital Signature. Printed copies of this
STATE OF document are not considered signed and scale(
and the SHA authentication code must be
N verified on electronic copies.
Attn: To Whom It May Concern
0 R 10
vX
1111141AJ,W\� \ ,
A field observation of the existing structure at the address indicated above was performed by a site survey team from Sunrun. Structural
evaluation of the loading was based on the site observations and the design criteria listed below.
Design Criteria:
• 2020 FBC (7th Ed.) AMENDMENTS TO 2018 IRC/IBC/IEBC, 7-16 ASCE & 2018 NDS
• Basic Wind Speed V = 138 mph, Exposure C
• Ground Snow Load = 0 psf
Based on this evaluation, I certify that the alteration to the existing structure by the installation of the PV system meets the requirements of the
applicable existing and/or new building code provisions referenced above.
Additionally, I certify that the PV module assembly including all attachments supporting it have been reviewed to be in accordance with the
manufacturer's specifications.
225 Bush St. Suite 1400 San Francisco, CA 94104
Astra v.1.765
February 23, 2023
sunr U n WS
CAT 1
Subject :Structural Certification for Proposed Residential Solar Installation.
VA E James Matthew Walsh. State of Florida,
PV
/I-
Job Number: 802R-414DRAY; Rev A
Professional Engineer, License No. 84923
X "I
Client: Damien Drayton
kp <-
This item has been digitally signed and sealed
Z� No,849 23
Address: 8414 Wheat Stone Dr, Zephyrhills, FL, 33540
by James Matthew Walsh, PE on 2/23/2023
2, z:, fing a Digital Signature. Printed copies of this
/5STATE OF document are not considered signed and seale(
0 and the SHA authentication code must be
;%,, A, verified on electronic copies.
N
Attn: To Whom It May Concern
/ a /ONAL 0\\\'
//;
/14141w%0
A field observation of the existing structure at the address indicated above was performed by a site survey team from Sunrun. Structural
evaluation of the loading was based on the site observations and the design criteria listed below.
Design Criteria:
• 2020 FBC (7th Ed.) AMENDMENTS TO 2018 IRC/IBC/IEBC, 7-16 ASCE & 2018 NDS
• Basic Wind Speed V = 138 mph, Exposure C
• Ground Snow Load = 0 psf
Based on this evaluation, I certify that the alteration to the existing structure by the installation of the PV system meets the requirements of the
applicable existing and/or new building code provisions referenced above.
Additionally, I certify that the PV module assembly including all attachments supporting it have been reviewed to be in accordance with the
manufacturer's specifications.
225 Bush St. Suite 1400 San Francisco, CA 94104
BREAKING THE 20% EFFICIENCY BARRIER
Q.ANTUM DUO Z Technology with zero gap cell layout
boosts module efficiency up to 21.4%.
THE MOST THOROUGH TESTIN13 PROGRAMME IN THE INDUSTRY
Q CELLS is the first solar module manufacturer to pass the most comprehen-
sive quality programme in the industry: The new "Quality Controlled PV" of
the independent certification institute TOV Rheinland.
INNOVAT11VE ALL-WEATHER TECHNOLOGY
Optimal yields, whatever the weather with excellent
low -light and temperature behavior,
ENDURING HIGH PERFORMANCE
Long-term yield security with Anti LID Technology, Anti PID
Technology', Hot -Spot Protect and Traceable Quality Tre.QTM.
EXTREME WEATHER RATING
High-tech aluminum alloy frame, certified for
high snow (5400 Pa) and wind loads (4000 Pa),
29 A REUABLE iNVESTSENT
VY Inclusive 25-year product warranty and 25-year
linear performance warranty.
APT test conditions according to [EC/TS 62804-1:2015, method A (-1500V, 96h)
See data sheet on rear for further information.
THE IDEAL SOLUTION FOR:
6:9 Rooftop arrays on
residential buildings
Engineered in Germany OCELLS
MECHANICAL SPECIFICATION
74.0 in x 41.1 in x 1.26 in (including frame)
(1879 mm x 1045 mm x 32 mm)
48.5Ibs (220 kg)
0131n (3.2 mm) thermally pre stressed glass with
anti reflection technology
Composite film
Black anodized aluminum
6 x 22 monocrystalline Q.ANTUM solar half cells
.. , �.�..
2.09-3.98in x 1,26-2,36in x 0.59-0.711n
(53-101 mm x 32-60 mm x 15-18 mm), I P67, with bypass diodes
4mm2 Solar cable; (+) a49.2 in (1250 mm), (-) a49.2 in (1250 mm)
....... .. . .. . ........ ...... .... ......... ... ............. ....
.. .
........ . .................
St6ubli MC4; IP68
]a.0"(18J9 )
±6.6'(395.Smm)
4+.1-,g ppms a 0.18' (4 5 rtxn) F,eme-
39.2"(S9fi mm)
411' (1045 mm)
I
�49.2 _fi25p mmj) 'r
-���" �^ Bx Drelna9e twles
_ 4x Mowtiig sb,a (DEiAILA) -
DETNLn-
v-(24,5mm) 1- �-- I-3 (8 MM)
ELECTRICAL F TISTI S
POWER CLASS 395 400 405 410 415
F . )
PMPP [W] 395 400 405 410 415
[A] 11/3 11.16 11.19 11.22 11,26
Von IV] 4503 45.06 45,09 4013 4516
....
IMPP [A] 10.58 10.64 10,70 10 76 10,82
-VMPP - IV] - 37.32 37.59 37,85 38.11 38,37
........ . .......... __. .....,... ..
' 7 (%] >_201 a204 >206 >20.9 >211
_ _.... _......� .. ..
?, +,
.'............ _ ....
Purl, [W] 296.4 300.1 303.9 307.6 311.4
c [A] 8.97 8.99 9,02 9.04 9.07
_ .
Voc [V] 42.46 42.49 42.52 42.66 42.59
MPP [A] 8.33 8.38 8.43 8.48 8,53
_ VMPP [VI 35.59 35,82 36.04 36,27 36.49
'Measurement tolerances P_±3%; Ific; V�� ±5%at STC:1000W/m2, 25±2°C, AM 1.5 according to IEC 60904-3. 2800 W/m2, NMOT, spectrum AM 1.5
Q CELLS PERFORMANCE WARRANTY PERFORMANCE AT LOW IRRADIANCE
At least 98% of nominal power during
firstyear. Thereafter max. 0.5%
------------------ degradation peryear.Atleast93.5%
of nominal power up to 10 years. At
t least 86 % of nominal power up to
� Tt 25 years. ----------------------------
All data within measurement toferanc-
°, tit��T T es Full warranties in accordance with &O -
L� a1,r�T° zoo aan aoo soo a000
the warranty terms of the Q CELLS
ea
sales organisation of your respective
J a zo country.
Typical module performance under low irradiance conditions in
comparison to STC conditions (25°C,1000 W/m2)
TEMPERATURE COEFFICIENTS
Note: Installation Instructions must be followed, See the installation and operating manual or contact our technical service department for further Information on approved installation and use of
this product.
Nanwha C CELLS America Inc.
400 Spectrum Center Drive, Suite 1400, Irvine, CA 92618, USA I TEL+1949 748 59 961 EMAIL inquiry@us.q-cells.com I WEB www.q-cells.us
BREAKING THE 20% EFFICIENCY BARRIER
Q,ANTUM DUO Z Technology with zero gap cell layout
boosts module efficiency up to 21.4%.
THE MOST THOROUGH TESTING PROGRAMME iN THE INDUSTRY
Q CELLS is the first solar module manufacturer to pass the most comprehen-
sive quality programme in the industry: The new "Quality Controlled PV" of
the independent certification institute TOV Rheinland.
INNOVATiVE ALL-WEATHER TECHNOLOGY
Optimal yields, whatever the weather with excellent
low -light and temperature behavior.
ENDUMING HIGH PERFORMANCE
Long-term yield security with Anti LID Technology, Anti PID
Technology', Hot -Spot Protect and Traceable Quality Tra.QTM.
EXTREME WEATHER RATING
High-tech aluminum alloy frame, certified for
high snow (5400 Pa) and wind loads (4000 Pa).
A RELIABLE INVESTMENT
Inclusive 25-year product warranty and 25-year
linear performance warranty2.
'APT test conditions according to lEC/TS 62804-1:2015, method A (-1500V, 96h)
2 See data sheet on rear for further information.
THE IDEAL SOLUTION FOR:
6nRooftop arrays on
residential buildings
Engineered in Germany OCELLS
MECHANICALSPECIFICATION
1 482'(IZSOmmj
a x Orounding pdNi a 018" (a.6 mrtQ Frame
I --
39.T' (998 mm)
I
I
41.1'`�1046mm)
Laapl-C..�
zas.z" azso mm)
=i� 8 x Orairw9e M1des
k axMountirgsiais (QEfAIL A) -
�126"(3T tmN OETNLA 0.63"(I6 mm)
t-
1_
0.9R'{tab mm} 103R")R.bmm) �
ELECTRICAL CHARACTERISTICS
POWER GLASS
__.
395
400
....,,..
405
..,...... " .... ....".
410
...... .. w. ..........
415
_
.
....
PMPP
[W]
395
400
405
410.
415
[so
[A]
11.13
11.16
11,19
11,22
11.26
Voo
[V]
45,03
45.06
45.09
45,13
45.16
I.,
[Al
10,58
10.64
10.70
10.76
1.0.82
Vnarr
IV]
3732
3759
37.85
38.11
3837 _.
..
n
[%]
>_20.1 _
>_20.4
... ._
>_20.6
_ "
>_20,9
. ,.w...... ...... .
>_21.1
...... ....,.w-_
MPP
[W]
-
296.4
300.1
303.9
3076
311.4
Isc
[A]
8.97
8.99
9.02
9.04
9.07
Vo o
IV]
42.46
42.49
42.52
.... .a.
42 56
n.� .....,
42.59
." w.._ a
_
MPP
.
[A]
�......
8.33
8.38
8.43
8.48
8.53
VMrP
(V]
35.59
35.82
36.04
36.27
36,49
_...
'Measurement tolerances Pm,, t3%; I$G, Von t5% at STC:1000 W/m2, 25t2'C, AM 1.5 according to [EC 60904-3.2800VV/m2,
NMOT, spectrum AM L5
0 CELLS PERFORMANCE WARRANTY
PERFORMANCE AT LOW
IRRADIANCE
aso A0
TEMPERATURECOEFFICIENTS
At least 98 %of nominal power during ' no r
first year. Thereafter max. 0.5 %
degradation per year. Atleast 93.5%
of nominal power up to 10 years. At.,.
least 86% of nominal power up to
25 years. y ao �-
All data within measurement toleranc- `
eo
es. Full warranties in accordance with zoo aoo sao eao iaao
the warranty terms of the Q CELLS
sales organisation of your respective
country.
Typical module performance under low irradiance conditions in
comparison to STC conditions (25 °C,1000 W/m2)
a [%/K] +0.04 E,}': t "' , Q [%/K) -Q27
y� [%/K] -0.34 " _ _.. NMOT ['Fj 109±5.4(43t3°C)
PROPERTIES FOR SYSTEM DESIGN
Note: Installation instructions must be followed. See the installation and operating manual or contact our technical service department for further information on approved installation and use of
this product.
hlanwha Q CELLS America Inc.
400 Spectrum Center Drive, Suite 1400, Irvine, CA 92618, USA I y EL -1949 748 59 961 EMML inquiry@us.q-ce is.com I WEB www.q-cells.us
7
WSHEETINDEX
ESCRIPTI N
- SYSTEM SIZE: 640OW DC, 600OW AC
- ALL WORK SHALL COMPLY WITH 2O20 FBC (7TH ED.) AMENDMENTS TO 2018
ED
SERVICE ENTRANCE
» MODULES: (16) HANWHA Q-CELLS: Q.PEAK DUO BLK
IRC/IBC/IEBC, MUNICIPAL CODE, AND ALL MANUFACTURERS` LISTINGS AND
.COVED
SHEET
ML-G10+ 400
INSTALLATION INSTRUCTIONS.
PV-2.0
SITE PLAN
m INVERTERS: (1) SOLAREDGE TECHNOLOGIES:
® PHOTOVOLTAIC SYSTEM WILL COMPLY WITH NEC 2017.
MP
MAIN PANEL
SE600OH-USSR
PV-3.0
LAYOUT
RACKING: TOPSPEED, SEE DETAIL SNR-DC-30004
® ELECTRICAL SYSTEM GROUNDING WILL COMPLY WITH NEC 2017,
PV-4.0
ELECTRICAL
SP
SUB -PANEL
- ADD NEW 150A MAIN BREAKER TO SUB -PANEL.
® PHOTOVOLTAIC SYSTEM IS UNGROUNDED. NO CONDUCTORS ARE SOLIDLY
PV-5.0
SIGNAGE--
—
GROUNDED IN THE INVERTER. SYSTEM COMPLIES WITH 690.35.
LC
PV LOAD CENTER
- MODULES CONFORM TO AND ARE LISTED UNDER UL 1703.
INVERTER CONFORMS TO AND IS LISTED UNDER UL 1741.
SM
SUNRUN METER.
RACKING CONFORMS TO AND IS LISTED UNDER UL 2703.
PM
DEDICATED PV METER
- SNAPNRACK RACKING SYSTEMS, IN COMBINATION WITH TYPE I, OR TYPE II
MODULES, ARE CLASS A FIRE. RATED.
INV
INVERTER(S)
RAPID SHUTDOWN REQUIREMENTS MET WHEN INVERTERS AND ALL
t�tlEkt!!t!(Fft(!
tip ` o A. Vlt'
CONDUCTORS ARE WITHIN ARRAY BOUNDARIES PER NEC 690.12(1).
AC
AC DISCONNECT(S)
CONSTRUCTION FOREMAN TO PLACE CONDUIT RUN PER 690.31(G).
No. 85ill
WE
DC
DC DISCONNECT(S)
e ARRAY DC CONDUCTORS ARE SLED FOR DERATED CURRENT.
s a
ATE 0
. � %
11.14 AMPS MODULE SHORT CIRCUIT CURRENT.
J-//G,. 4.
a
IQ COMBINER BOX
17.4 AMPS DERATED SHORT CIRCUIT CURRENT [690.8 (A) & 690.8 (B)}.
ryPae
// V °veaoaeow° V 4�\
EXPIRES: 2/28/2025
ABBREVIATIONS
SIGNED: 02/22/2023
f—7
INTERIOR EQUIPMENT
A
AMPERE
L _J
SHOWN AS DASHED
AC
ALTERNATING CURRENT
sunrun
AFC
ARC FAULT" CIRCUIT INTERUPTER
CHIMNEY
ENGINEER ADDRESS:
AZIM
AZIMUTH
225 BUSH ST, SUITE 4400
SAN FRANCISCO. CA 94104
COMP
COMPOSITION
P: 949-383-0993
DO
DIRECT CURRENT
ATTIC VENT
EC13007964
VICINITY MAP
(E)
EXISTING
FLUSH ATTIC VENT
5208 TAMPA W BLVD, TAMPA, FL 33634
ESS
ENERGY STORAGE SYSTEM
PVC PIPE VENT
:n
PHONE b
FAX
EXT
EXTERIOR
_
METAL PIPE VENT
CUSTOMER RESIDENCE:
INT
INTERIOR
DAMIEN DRAYTON
T-VENT;
„. Ale
8414 WHEAT STONE DR,
MSP
MAIN SERVICE PANEL
ZEPHYRHILLS, FL, 33540
(N)
NEW
SATELLITE DISH
NTS
NOT TO SCALE"
TEL. (813) 990-9052
oc
ON CENTER
FIRE SETBACKS
APN: 26-25-21-0150-00200-0350
PRE-FAB
PRE -FABRICATED
PROJECT NUMBER:
802R-414D Y
PSF
POUNDS PER SQUARE FOOT
! HARDSCAPE
V
PV
PHOTOVOLTAIC
,������
DESIGNER: 415 580-6920 ex3
( }
RED
RAPID SHUTDOWN DEVICE
— PL—
PROPERTY LINE
CARLOS BRACAMONTES
TL
TRANSFORMERLESS
SOLAR MODULES CALF: NTS
SHEET
TYP
TYPICAL
t 1 COMMENTS
PaEU NAME DATE
COVER ET
V
VOLTS19
"
W
WATTs-
a
f
REV: A 212212023
LAN
LANDSCAPE
—
TOPSPEED
f ,,.:
PAGE
tt ®E
MOUNT
6
.tJ
FOR PORTRAIT
Teroniate version 4.O.R7
SITE PLAN - SCALE = 1/16" = V-011
9
anm
ke- E M
No 84923A1,
10
%a STATE OF
tORID
0
NAL
2/23/2023
ROOF INFO
Name Type
AR-01 COMP SHINGLE -
TOPSPEED
DI - AR-01 - SCALE: 1/8" = 1 `-1)"
- y
Minimum Number of Mounts per
Up -Slope Edge
I
4
51,
CRITERIADESIGN
Max Portrait i -
Overhang SNOW LOAD: 0 PSF
WIND SPEED:
j` MPH 3-SEC GUST.
SCREW
• X' ► Y SEALING
WASHER
E ! i SCREWS
PENETRATINGR •s
DEC�C.
VA E
4 143
STATE OF
ORM
NAL
0#0.
2/23/2023
LA I
ENGINEER ADDRESS:
225 BUSH ST, SUITE 1400
SAN FRANCISCO, CA 94104
P: 949-383-0993
EC13007964
5208 TAMPA W BLVD, TAMPA, FL 33634
PHONE 0
FAX 0
SHEET
LAYOUT
REV: A ]f2TG/2023
PAGE IV ,
'7
120/240 VAC
SINGLE PHASE
SERVICE
METER #:
<-- DUKE ENERGY 8338020
UTILITY
GRID
EXISTING
150A MAIN
BREAKER
(END FED)
EXISTING 200A
MAIN PANEL
200A
FACILITY
MAIN BUS
LOADS
(N) 35A PV
BREAKER AT
OPPOSITE END
OF BUSBAR
NOTE: TOTAL PV BACKFEED = 31A
USED FOR INTERCONNECTION
CALCULATIONS
ffimnp��'
NEW 150A SQUARE D
MAIN DU222RB
BREAKER 3R, 60A,2P
120/240VAC
EXISTING
200A SUB
PANEL
SOLAREDGE TECHNOLOGIES:
SE6000H-USSN
6000 WATT INVERTER
LOAD RATED DO
DISCONNECT WITH AFCI
CONDUIT SCHEDULE
#
CONDUIT
CONDUCTOR
NEUTRAL
GROUND
I
NONE
(4) 10 AWG PV WIRE
NONE
(1) 6 AWG BARE COPPER
2
3/4" EMT OR EQUIV.
(4) 10 AWG THHN/THWN-2
NONE
(1) 8 AWG THHN/THWN-2
3
3/4" EMT OR EQUIV.
(2) 8 AWG THHN/THWN-2
(1) 10 AWG THHN/THWN-2
I
(1) 8 AWG THHN/THWN-2
E
EXISTING
EXISTING
EXISTING I
EXISTING
HANWHA Q-CELLS: Q.PEAK DUO BLK
P401 OPTIMIZER CHARACTERISTICS:
M L-G 10+ 400:
400 W
MIN INPUT VOLTAGE:
8 VDC
OPEN CIRCUIT VOLTAGE:
45.06 V
MAX INPUT VOLTAGE:
60 VDC
MAX POWER VOLTAGE:
37.59 V
MAX INPUT ISC:
12.5 ADC
SHORT CIRCUIT CURRENT:
11.14 A
MAX OUTRUT CURRENT:
15 ADC
SYSTEM SIZE:
6400 W
SYSTEM OPEN CIRCUIT VOLTAGE:
8 v
SYSTEM OPERATING VOLTAGE:
380 V
MAX ALLOWABLE DC VOLTAGE:
480 V
SYSTEM OPERATING CURRENT:
16,84 A
SYSTEM SHORT CIRCUIT CURRENT-
30 A
JUNCTION BOX PV MODULES
OR EQUIVALENT HANWHA Q-CELLS: Q.PEAK DUO BLK
ML-G 10+ 400
(16) MODULES
V - 74�� OPTIMIZERS WIRED IN:
(1) SERIES OF (8) OPTIMIZERS
(1) SERIES OF (8) OPTIMIZERS
L SOLAREDGE POWER OPTIMIZERS
P401
Q�(.) A VIZ
Q3
No, 85111
STATE OF
1 0 %
EXPIRES: 2/28/2025
SIGNED: 02/22/2023
11771 "ll.
ELECTRICAL SHOCK HAZARD
LABEL LOCATION:
INVERTER(S), AC/DC DISCONNECT(S),
AC COMBINER PANEL (IF APPLICABLE).
PER CODE(S): CEC 2019: 690.13(B), NEC
2017: 690.13(B)
DER SOURCE OUTPUT CONNECTION
RELOCATEDO NOT
THIS
E "- ie
LABEL LOCATION:
ADJACENT TO PV BREAKER (IF
APPLICABLE).
PER CODE(S): CEC 2019!
705.12(13)(2)(3)(b), NEC 2017:
705.12(B)(2)(3)(b)
LABEL LOCATION:
PHOTOVOLTAIC AC COMBINER (IF
APPLICABLE).
PER CODE(S): CEC 2019: 705.12(B)(2)(3)(e),
NEC 2017: 705A2(B)(2)(3)(c)
POWERDUAL
I 1111 IJ Ilp �IIQ IIII I IIIII
SOURCES: GRID
AND M; i ELECTRIC
SYSTEM
LABEL LOCATION:
UTILITY SERVICE METER AND MAIN
SERVICE PANEL.
PER CODE(S): CEC 2019: 705A2(13)(3), NEC
2017: 705.12(B)(3)
LABEL LOCATION:
ON EVERY JB/PULL BOX CONTAINING DC CIRCUITS.
LABEL LOCATION:
AC DISCONNECT(S), PHOTOVOLTAIC SYSTEM POINT OF
INTERCONNECTION,
PER CODES): CEC 2019: 690.54, NEC 2017: 690.54
LABEL LOCATION:
INVERTER(S), DC DISCONNECT(S),
PER CODE(S): CEC 2019: 690.53, NEC 2017: 690.53
LABEL LOCATION:
INSTALLED WITHIN T OF RAPID SHUT DOWN
SWITCH PER CODE(S): CEC 2019: 690.56(C)(3), NEC
2017: 690.56(C)(3), IFC 2012:605.11A, IFC 2018:
1204.5.3, CFC 2019: 1204.5.3
LABEL. LOCATION:
ON OR NO MORE THAT 1 M (3 FT) FROM THE SERVICE
DISCONNECTING MEANS TO WHICH THE PV SYSTEMS
ARE CONNECTED.
PER CODE(S): CEC 2019: 690.56(C)(1)(a), NEC 2017:
690.56(C)(1)(a)
NOTES AND SPECIFICATIONS:
• SIGNS AND LABELS SHALL MEET THE REQUIREMENTS OF THE NEC 2017 ARTICLE
110.21(B), UNLESS SPECIFIC INSTRUCTIONS ARE REQUIRED BY SECTION 690, OR
IF REQUESTED BY THE LOCAL AHJ.
• SIGNS AND LABELS SHALL ADEQUATELY WARN OF HAZARDS USING EFFECTIVE
WORDS, COLORS AND SYMBOLS.
• LABELS SHALL BE PERMANENTLY AFFIXED TO THE EQUIPMENT OR WIRING
METHOD AND SHALL NOT BE HAND WRITTEN.
• LABEL SHALL BE OF SUFFICIENT DURABILITY TO WITHSTAND THE ENVIRONMENT
INVOLVED.
• SIGNS AND LABELS SHALL COMPLY WITH ANSI Z535.4-2011, PRODUCT SAFETY
SIGNS AND LABELS, UNLESS OTHERWISE SPECIFIED.
• DO NOT COVER EXISTING MANUFACTURER LABELS,
tt��iti6aa66flS tad ttJ� P`
No,86111
r� STATE OF
ie/ S0/0NALtt�
EXPIRES: 2128/2025
SIGNED: 02/22/2023
l e77plam} Verstoq_4. U,61