HomeMy WebLinkAbout23-5816City of Zephyrhilis 5335 Eighth Street Zmli Zephyrhills, FL 33542 ELCMISC-005816-2023 Phone: (813) 780-0020 Issue Date: 03/10/2023 Fax: (813) 780-0021 REINSPECTION FEES: (c) With respect to Reinspection fees will comply with Florida Statute 553.80(2)(c) the local government shall impose a fee of four times the amount of the fee imposed for the initial inspection or first reinspection, whichever Is greater, for each subsequent reinspection, Notice: In addition to the requirements of this permit, there may be additional restrictions applicable to this property that may be found in the public records of this county, and there may be additional permit required from other governmental entities such as water management, state agencies or federal agencies. "Warning to owner: Your failure to record a notice of commencement may result in your paying twice for improvements to your property, If you Intend to obtain financing, consult with your lender or an attorney before recording your notice of commencement." Complete Plans, Specifications add fee Must Accompany Application. All work shall be performed in accordance with City Codes and Ordinances. NO OCCUPANCY BEFORE C.O. NO OCCUPANCY BEFORE C.O. J ov, CONTRACTOR SIGNATURE PERMIT EXPIRES IN 6 MONTHS W PE IT OFFICE ITHOUT APPROVED INSPECTION 813-780-0020 City of Zophyrhilis Permit' Application Pax-81$-780-0021 Building Department Cate Received Pt€one Ccarttact For Permettlo 727 7i-7A42 �PAT�RICIANEAM�ON 585-A92-3209 Owner's Name Owner Phone Number lit..,,,,...... 376pg NEW HORIZONS BLVD Owner's Address Owner Phone Number Fee Simple Titleholder Name � Owner Phone Number Fee Simple Titleholder Address JOB ADDRESS 37605 NEW HC R(ZONS BLVCk LOT SUBDIVISION GRAND HORIZONS �� PARCEL ID#34-25-29-0090-00000-0530 (OSTAiNEO PROM PROPERTY TAX NOTECia WORK PROPOSED � NEWCUNSTR� ADDALT SIGN DEMOLISH INSTALL REPAIR PROPOSED USE SFR COMM OTHER PE OF CONSTRUCTION BLOCK FRAME STEEL DESCRIPTION OF WORK RQOF Mt�UNTED SOLAR PV SYSTEM INSTALLATiC}N (8.14 KW) BUILDING SIZE ,,= Sty FOOTAGE HEIGHT BUILDING $= VALUATION OF TOTAL CONSTRUCTION ELECTRICAL $ 21571� AMP SERVICE PROGRESS ENERGY = W.R.E.0 =PLUMBING $ j���=MECHANICAL $�KK VALUATION OF MECHANICAL INSTALLATIC?N GAS ROOFING = SPECIALTY = OTHER FINISHED FLOOR ELEVATIONS == FLOOD ZONE AREA =YES NO BUILDER COMPANY SIGNATURE � REGISTERED Y 1 N nos CURREN Y 1 N Address License # ELECTRICIAN t � COMP Y SOLAR BEAR LLC SIGNATURE REGSTsze9 Address YfN EEcuRREN YIN .� 4091 jAMTC CENTER CAR E ecaaooesao License # _ PLUMBER COMPANY SIGNATURE E=== REGISTERED N F 6cuRREN Y f N Address License #..�._,. ..._�.I �AECiiANiCAl. �..�..._. � COMPANY E �.._..._.._. SIGNATURE REG srsREa Y i N� r=_e cuRREN Y 1 N �� Address License # OTHER COMPANY SIGNATURE REGISTERED Y f N FEE cuRREri �Y f N Address License # � .,,. 0 1 1 0 O O t I I 0 0 I I I a at is 1912419131111111 1#119P RESIDENTIAL Attach (2) Plot Plans; (2) sots of Building Plans; (1) set of Energy Forms; R-O-W Permit for new construction, Minimum ten (10) working days after submittal date. Required onsite, Construction Plans, Stormwater Plans wi Silt Fence installed, Sanitary Facilities It 1 dumpster; Site Work Permit for subdivisions/large projects COMMERCIAL Attach (2) complete sets of Building Plans plus a Life Safety Page„ (1) set of Energy Forms, R-O-W Permit for new constructions. Minimum ten (10) working days ;fifer submittal date. Required ouster, Construction Plans, Stormwster Plans wi Silt Fence installed, Sanitary Facilities A "Idumpster. Site Work Permit for all now projects. All commercial requirements must meet compliance SIGN PERMIT Attach (2) sets of Engineered Plans. -PROPERTY SURVEY required for all NEW construction. Directions: Fill out application completely. Owner & Contractor sign back of application, notarized If over $2500 A Notice of Commencement Is required. QVC upgrades over $7500) Agent (for the contractor) or Power of Attorney (for the owner) would be someone with notarized letter from owner authorizing same OVER THE COUNTER PERMITTING (copy of contract required) Recants if shingles Sewers Service Upgrades A/C Fences (Plot/Survey/Footage) Driveways -Not over Counter if on public madways..needs ROW 813-780-0020 City of Zephyrhilis Permit Application Fax•813-780-0021 Building Department NOTICE OF HEED RESTRICTIONS: The undersigned understands that this permit may be subject to "deed' restrictions" which may be more restrictive than County regulations, The undersigned assumes responsibility for compliance with any applicable deed restrictions. UNLICENSED CONTRACTORS AND CONTRACTOR RESPONSIBILITIES: If the owner has hired a contractor or contractors to undertake work, they may be required to be licensed In accordance with state and local regulations. If the contractor is not licensed as required by law, both the owner and contractor may be cited for a misdemeanor violation under state law. if the owner or Intended contractor are uncertain as to what licensing requirements may apply for the intended work, they are advised to contact the Pasco County Building Inspection Division --Licensing Section at 727-847- 8009, Furthermore, if the owner has hired a contractor or contractors; he is advised to have the contractors) -sign portions of the "contractor Blank" of this application for which they will be responsible- If you, as the owner sign as the contractor, that may be an indication that he is not properly licensed and is not entitled to permitting privileges in Pasco county. TRANSPORTATION IMPACT/UTILITIES IMPACT AND RESOURCE RECOVERY FEES: The undersigned understands that Transportation Impact Fees and Recourse Recovery Fees may apply to the construction of new buildings, change of use in existing buildings, or expansion of existing buildings, as specified in Pasco County Ordinance number 89-07 and 90-07, as amended. The undersigned also understands, that such fees, as may be doe, will be identified at the time of permitting. it is further understood that Transportation Impact Fees and Resource Recovery Fees must be paid prior to receiving a "certificate of occupancy" or final power release. If the project does not involve a certificate of occupancy or final power release, the fees must be paid prior to permit Issuance. Furthermore, if Pasco County Water/Sewer Impact fees are due, they must be paid prior to permit issuance in accordance with applicable Pasco County ordinances. CONSTRUCTION LIEN LAW (Chapter 713, Florida Statutes, as amendaad): If valuation of work is $2,500.00 or more, I certify that I, the applicant, have been provided with a copy of the "Florida Construction Lien Law --Homeowner's Protection Guide" prepared by the Florida Department of Agriculture and Consumer Affairs, if the applicant is someone other than the 'owner", I certify that I have obtained a copy of the above described document and promise in good faith to deliver It to the "owner" prior to commencement. CONTRACTOR'SfO NER'S AFFIDAVIT I certify that all the information in this application is accurate and that all work will be done in compliance with all applicable laws regulating construction, zoning and land development. Application is hereby made to obtain a permit to do work and installation as indicated. I certify that no work or installation has commenced prior to issuance of e permit and that all work will be performed to meet standards of all laws regulating construction, County and City codes, zoning regulations, and land development regulations in the jurisdiction, I also certify that I understand that the regulations of other government agencies may apply to the intended work, and that it is my responsibility to Identify what actions I must take to be in compliance. Such agencies include but are not limited to: Department of Environmental Protection -Cypress Sayheads, Wetiand Areas and Environmentally Sensitive Lands, WaterlWastewater Treatment. Southwest Florida Water Management District -Wells, Cypress Sayheads, Wetland Areas, Altering Watercourses, Army Corps of Engineers -Seawalls, Clocks; Navigable Waterways. Department of Health & Rehabilitative Services/Environmental Health Unit -Wells, Wastewater Treatment, Septic Wanks, US Environmental Protection Agency -Asbestos abatement, Federal Aviation Authority -Runways, i understand that the following restrictions apply to the use of fill: Use of fill is not allowed in Flood Zone ' V" unless expressly permitted. If the fill material is to be used in Flood Zone "A" it is understood that a drainage plan addressing a °compensating volume" will be submitted at time of permitting which is prepared by a professional engineer licensed by the State of Florida. R If the fill material is to be used in Flood Zone "A" in connection with a permitted building using stem wall construction, I certify that fill will be used only to fill the area within the stem wall. If fill material is to be used in any area, I certify that use of such fill will not adversely affect adjacent properties. If use of fill is found to adversely affect adjacent properties, the owner may be cited for violating the conditions of the building permit issued under the attached permit application, for lots less than one (1) acre which are elevated by fill, an engineered drainage purl is required. If I am the AGENT FOR THE OWNER, I promise in good faith to inform the owner of the permitting conditions set forth in this affidavit prior to commencing construction, I understand that a separate permit may be required for electrical work, plumbing, signs, wells, pools, air conditioning, gas, or other installations not specifically included in the application. A permit issued shall be construed to be a license to proceed with the work and not as authority to violate, cancel, after, or set aside any provisions of the technical codes, nor shall issuance of a permit prevent the Building Official from thereafter requiring a correction of errors in plans, construction or violations of any codes. Every permit issued shall become invalid unless the work authorized by such permit is commenced within six months of permit issuance, or if work authorized by the permit is suspended or abandoned for a period of six (6) months after the time the work Is commenced. An extension may be requested, in writing, from the Building Official for a period not to exceed ninety (90) days and will demonstrate justifiable cause for the extension, If work ceases for ninety (90) consecutive days, the job Is considered abandoned. WARNING TO OWNER, YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY, IF YOU INTEND TO OBTAIN FINANCING, CONSULT Sub Gnd sworn to for affirmed before me this Jo -,by a by °a} Who is/are personally known to me or eras/have produced 0as identification, Notary Public ommi ion No, iG f Ct Name of Notary typed, printed or stamped tit Joseph Tribou - Notary Public. ,ra —State of Florida 1P Comm# HFita 9907 Expires 12/7/2024 sm tiA BRrrTANY TRISOU Notary Public State of Florida cart° m# HH260991 c g� Expires 5J4/22 INSTR#2023031694ORBK10770 PG2805 Peg, 1 pf 1 02/21/2023 11:32 AM Rcpt: 2553612 Rec: 10,00 CIS: 0,00 IT: 0,00 Nikki Alvarez-Sowles, Esq., Pasco County Clerk & Comptroller Permit Number NMWID Number ON 6- NIOTICE OF COMMEPICEPAENT Slate Of Florida County of THE UNDERSIGNED-hemby Owes notice that Irnprovernents will be made In, certain mal property, and in Kwthlftcs with Soon on 713 13 of the Floddo Statutes, the to" info bon is proveled in this NOTICE OF COMMENCEMENT, D04C40"efistap"fAvaidatedotton): 6CA0D HAIM- PH(Kt' UV)'F, -14 P(js ix-r G5 5z a) aeret, Vob) Addmss: kein 2-134"rid description of Improvementil: INSTALL SOLAR PV SYSTEM 310*fw Infwmglon or Loan InfOrnsdon If the iA*m contracted for the Improvivrorat: L)jp NaMbN !)-Ik� tJ(-_-W HLI,rw4 6 b) Norm and Address of too simals titleholder (it diffetent than Owner listed above) C) Interest in Property: 11091%, 44codrador Inforinatkm a) Narria and addrM: NOR MAN E PURKEY- SOLAR BEAR LLC 4091 AMTC CENTER, GLEARVVA7E FL b) Telephone No,: '(727) 470442 Fax No.:(o0MQ &Surety (if applicabile, a copy of Me payment bond is attached) a) Naar and alltws: lr, b) Telephave No,: ..... .. .... .. . ..... . ... ... .. ..... . ... ..... .. C) Amount of Bond: ........... S. Lender a) Na rne a b) Telephorle No.: __ � .......... 1� penw" wtWio tM Sto of nw* d"IQn*d by Otow anne whom noto" or otw doormer" may be SeNw as Pvidw bY Sacwt, 713,13 (1) (a) T. Florida Swm: 8) Name and address: b) Telephone No,,- Fax No.: (oPdoft8pOf In xwjdan to hh5eff or her*4­ ........ .. . ded in Sept 713. 13 (1) (b), Florida Statubm, by0arier: (the exomilon data MY W be belom the complefion of conshiefion and final pronent to the lawrting unless a different date is specifired): "20,_ ME BY TOE OR AFTOR T14E EXPIRATION OF THE NOTICE OF COMMENCEMENT ARE CHAPTER 113, pART I, SECTION 713AFLORIDA STATUTES, AND CAN RESULT IN YOUR rWE FOR IMpRovEMENTS TO YOUR PROPERTY, A NOTICE OF COMMENCEMENT MUST BE RECORDED AND POSTED ON THE " SITE BEFORE THE FIRST INSPECTION, OF YOU INTENO TO OBTAIN FINANCING, CONSULT WN YOUR LENDER OR AN ATTOMW BEFORE COMMENCING WORK OR RECORDING YOUR NOTICE OF COMMENCEMENT, Uralta Orb* of Perjury, I dedaM drat I We Moo the fersillorq notice of cote leencermint and that the fads stated therein am true IS ft bft of my n'Of, _Drro" � r)Pffit NNW Ord Pmv* S080ya, Taw, offi", ,,swatcp" W Lowe, Ofo*T* 4(yL8004, (&,#ortA(0#kW/0V0d0A*WNftftW) (so f0mTrynvansof [0 physical prounce or 6 on4inenotatizablen'm day The ft AwUment was ocknoorled -is, I I (type of aultrodty, Itro, 0111cor, trustee, aftwert 61 fad) Of MW LPA QKC� , '04 ,j 0 �#brmy jor (Naft of POMW Irene or n" on Wolf W wtom 0 wet Air pemovy waiar 0 Produced ID V Notary ftnisture Type Of 10 print name LAURA CAMPERO Notary Public State of Florida Carr m#HH1S0225 Expires 7/7/2025 GODWIN ENGINEERING AND DESIGN, LLC 8378 Foxtail Loop, Pensacola, FL 32526 1 (850)712-4219 1 ��hjjqt@?gaLlyvirjg, To: Zephyrhills Building Department 5335 8th St. Zephyrhills, FL 33542 Re: Nearnon - Residential Pv Roof Mount Installation 37609 New Horizons Blvd Zephyrhills, FL 33541 This letter is regarding the installation of a new roof mounted Solar PV System on the existing residential structure at the address above, I have reviewed the attachment plan and have determined that the roof mounted PV system is in compliance with the applicable sections of the following Codes as amended and adopted by the jurisdiction: 2020 Florida Building Code 7th Edition, FBC ASCE 7 Min, Design Loads for Buildings & Other Structures Per 2020 FBC, the Roof Mounted PV system will be subject to the following design criteria: Design Wind Speed (V,,It) - 140mph 3sec gust, Exposure Category - C The PV System consist of the modules, railing, and connection hardware, The system will add a (lead load of approximately 3 psf to the roof, The existing roof covering is TPO with min. %"plywood decking and 2" x 4" roof trusses 24"O,C. The roofing, decking, and roof trusses are in good condition. The existing structure will be adequate for supporting the additional PV dead load and wind loads. The securement method of the PV system is to be flush mounted to the TPO roof with the Iron ridge railing and Standoff E-curbs. The attachments can be attached up to 32" apart in roof zones 1, 2e, 2n, 2r, 3e, & 3r, The mounts should be staggered, where possible, to allow distribution of the design loads evenly to the structure. The mounts shall be installed using 2 x 5/16" x 4" stainless steel Lag bolts with minimum 2-5/16" thread length directly to the roof truss. Please see attached documents and contact one should you have any questions. Sincerely, D. Chad Godwin, PE 81360 Exp,02/28/2025 C-. 0, 3 6 0 ATE OF ON A L /10/111110\\ 1 1, �wln� Inverter Type: (22)Enphase IQSPLUS-72-2-US PV Panel: (22) SIL-370 FIC Racking: K2 Total Wattage: 8,140W DC Roof Type: TPO Wind Load: 8 to 20 Deg Fastener Type: Use Standoff E-curbs Sheet Index S-1 Cover Sheet / Site Plan S-2 Detail E-I One - Line E-2 Electrical Code S-IA Mounting Plan General Notes: -Enphase IQ8PLUS-72-2-US Micro Inverters are located on roof behind each module. -First responder access maintained and from adjacent roof. -Wire run from array to connection is 40 feet. T a 63 a FL3 727 7�7 74414 2 Meter Located oil Pole Meter Main Combo 1 " L 3' 1 ',- iegend First responder access ? Chimney Lftility Meter Satellite PV Disconnect 0 Vent Pipe -COGE'N Disconn�ect Located adjacent to Utility n)etcr Modules (22) I N Tr F1 "I FRO-,tio-w Syst,enii �i)ccts thc re(�U I i-C111CII, IS ofN I 'I" A 70th I �'(.] i tion, 0 -1,apler 1 1, 12 (2018 IFdition '� I I nstal 1 S, , 11 be done to AVM anu!"aCtUrer Spec Meets All Editions of Florida Fire Prevention Code 2020 7th Edition Meets al I requirements of 2018 Editions of NFPA- I and NFPA- 10 1 7-- c Z�Z/Z J Represents all Fire Clearance I st Responder Access including Alternative methods minimum of 36" unobstructed as per Section R324 of the 2020 IRC Meets the requirements of the following- (2020 FL Residential Code & FBC, 7th Edition (2020 tnternational Residential Code) - 2nd Printing modified by the FL Building Standards, 2020 Florida Building Energy Conservation Code 7th edition, City of Zephyrhills Code, 2017 National Electric Code.) LTM_119111�� W112WKWUPIMM ";�] W2, VA I M[ Design, LLC 8378 Foxtail Loop Pensacola, FL 32526 D. Chad Godwin, PE Chadagodwineng.com Revised bv: Rev Date: IINIT' S-1 C. - -, Z60 c) TE OF N ts� A I A L 1/0111110" ComDass for Aerial -4" Standoffs are securing into rafters @ 32" O.C. in Zone 1, @ 32" O.0 in Zone 2e, @ 32" O.C. in Zone 2n,@ 32" O.C. in Zone 2r, @ 32" O.0 in Zone 3e, & @ 32" O.C. in Zone 3r using (2) 5/16" x 4" stainless steel Lag bolts. - Subject roof has One layer. ® All penetrations are sealed using w/ECurb. rKoof Section-1 Pitch', Roof Rafter and Spacing i RI it � 3/12 2 x4"O.C. -Roof fleight 15' Inverter Type: -Per 2020 FBC, the Roof Mounted PV System Psi Panel: will be stib : Ject to the following design criteriaRacking- Design Wind Speed(Vult) - 0mph 3 sec g-u-st 9 Total Wattage Exposure Category - C Roof Type: Wind Load: -Designed as per ASCE7-16 Fastener Type Standoff w/Eurb I fla (22)Enphase IQ8PLUS-72-2-US (22) SIL-370 FIC K2 8,140W DC TPO 8 to 20 Deg Use Standoff E-curbs PATRICIA & DAVID NEAMON 37609 NEW HORIZONS BLVD ZEPHYRHILLS, FL 33541 lnstaH will be done to Manut"Icturer Spec C. Go Godwin Engineering and �\C E �, 0 1 � q - Design, LLC 8378 Foxtail Loop z__ N 1360 Pensacola, FL 32526 D. Chad Godwin, PE 01 E OF # Chad (q7godwineng.corn 40RIO�'-_-_1 6z \zl� U/0 I US Rev Date: . Tage: # 10 AWG THWN for Home runs (1) Line I (1) Line 2 Per Circuit (1) EGC Inside (e_-4 least 3/4" Conduit (tbd on site) — ------ — ------- - -------------- Enphase Output Ckt Per String To Overcurrent Protection Device AC Max Output Current 1331 AC Max Output Current t 1.25% 16�6 Overcurrent Protection (A) 20 No. of Current _qarryipg_qoqd_____ <4 Conductor Gauge (AWG) 10 Enphase Total Output Ckt i AC Max Output Current 26.62 AC Max Output Current * 125% 1 33.3 1 Overcurrent Protection (A) No. of Current Carrying Cond <4 Conductor Gauge (AWG) 8 I Inicitiding the lahlel beloxv In Case of Emergency Call Solar Bear at 727-471-7442 EC #: EC13006630 Enphase IQ Trunk Cable Q- 12-240 #12AWG TFIFIN-THWN-2 UL 9703 Inverters: (22) Enphase IQ8PLUS-72-2-US Micro Inverters Grounding Conductor to be protected 1 Circuits: #8 Awg or to be unprotected tru Avvg 1 1 (2) circuits of (11) Modules 250.64(B) 250.66 & 250.120(C) Maximum Inverters Per 20A Circuit (13) Roof - 'OT" V60,Afib,1,$y18T8K 0, 44 Q q t KN RATED AC OUTPUT CURRENT: 26,62A N OMINAL OPERATING VOLTAGE 240VAC Enphase Combiner Box 4X-IQ-AMI-240 10A/15A 111A 20A Envoy -IQ Monitor i1! Main Service 200A 200A Bus 60A Fused Disconnect 40A Fuses Conduit (in) I L1,L2,N (Awg) I Ground (Awg) I OCPD After Combiner B 0,75 8 8 1 40 To Load Side Tap C 035 6 8 4(9 Note: -All wiring to meet the 2017 NEC and Florida electric codes. 60A Disconnect -Type of conduit to be determined on site by contractor. Mc,Lts 11,12.11.5 1 Install will be done 10 MaI1LIi'aCtLWel- S GEC NOTES Ungrounded system per 690,41 (A)(4) GEC must be Installed per 25064 GEC must be continuous un-spliced or irreversibly spliced from inverter to existing service ground system or continuous from the arrays to tire existing -service ground system. GEC' must be rnin #8 AWG and installed in conduit If GEC is not in conduit, it must be 46 min Disconnects will be Visible, lockable. adjacent to L , -'d with II � ill 110, of vaility I-neter All Labels & for photovoltaic systein will be rellective and meel all requirenients for NF PA 1: 11: L! NEC LABEL NOTES: 1, THE WARNING SIGN(S) OR LABEL(S} SHALL COMPLY VAT!- NEC 110.21 (B) M 2. LABELS SHALL BE SUITABLE FOR THE EWRONMENT VM.ERE THEY ARE INSTALLED. 3 LABELS TO BE A MIN LET FER HEIGHT OF 3/8" AND PERMANENTLY AFFIXED. 4, LABELS SHALL ALSO COMPLY OATH THE SPECIFIC REQUIREMENTS OF THE AUTHORITY HAVING JURISDICTION, G istribution F Li �p 200A Bus 6 1,1xisfing loatds tk) be relocated and Not,,flier loads can be added Per 705, 12(11)(2 ' Xl)(b) C- 0 Godwin Engineering and Design, LLC DC t60 200A Main 8378 Foxtail Loop Pensacola, FL 32526 0 rTA E COF 1,447 :z D. Chad Godwin, PE N, Chad�godwineng.corn G", ///'/ONAL 0' \\°� i6iEilil\ PATRICIA & DAVID NEAMOT 37609 NEW HORIZONS BLV ZEPHYRHILLS, FL 33541 1 6 101 Johns Rd, Ste 0A Tampa, FL 33634 727-471-7442 1 Date: 2/28/2023 Drawn by: AM Revised bv: Rev Dat Page: 11 x1T E-1-1 Inverter Type: Enphase IQ8P1,US-72-2-US PV Panel: (22) SiL-370 IIC Total Wattage: 8,14OW DC Svs'Leiyi nioens the ,irmundinis reciuirernents of']AFI-C 0901,113 Ilic Nacflrdl hail he pemlarl"filk w,eteand shall 'be mode ofrc hard plasrivt ah vdi,rc block [cnerm,2 -A p I acard wil I IN- ddcd ,vidl ,i1,-,N'u0;ons vnd locail'MI"s tO bo ;n comphance v, ith 690, t 2, Invefte- Output Ckt 6W56051) and Nil," 7 05, 1 o Overcurrent Protection Device lyapid Shutdovn 11UH1 it'l In cornpharluc ,� iffi NFIC 25059, NFIC 690.9, Fier Cod- N F( � 690, 12 N11C 25(121. NFC-1iO.?40)) PV 1°46_' tfisconnect is (onductors have Ll Dlin� lkabli e n the open positioir oc I oF60 amperes s"illelcit', I ,)or corle NFIC 705.22(7) Per Code N F,"C' 2 30,79(D) Everything,vill be built to Cote without all Sorecifics labeled on plar, System, is in coniphance with 1'1:1 4' I: I 1,12 7th FAh ion J,Iarkin­s shalt be placed on all DC Conduits, DC Coanbillers., Raccvrays, Flvclosures, Junction Boxes, rind Cable AsSemblies at eVerV Iff, tUrns. and above and below penctrations in compliance with, NHIA Disconnect means shall be provided for all disconnecting all Ungrounded conductors that supply or pass through the building or structure Per Code 20il'7 NEC Section 225.31 & Section 22S.32 E04, Construction documents specify PV system wouits installed on or in buildings Include a rapid shutdown furiction that controls specific conductors in accordance with NEC article 690. 12, E05. Fhese construction documents specify that a l@bel is Prowded with the rrieftd to initiate ,rapid shut down per 690.12(4). E06. Constructron drawings specibf buildings or structures with both utility service and a PV system, complying with NEC article 690.12 ,all have a permanent plaque odirectory including the foHowing,,vording: TIHOTO VOLTAIC SYST FM EQUIPPED WITH RAPID SHUTDOeVis" as Per NEC article 690.56 (C). E07. Construction documents specify PV power circuit labels shall appear on every section of the wking system that is separated by enclosures, walls, partitions, ceilings, or floors E08. Construction documents specipy, all warning sian's) or label(s) shall comply with NEC article 110.21 (B) Label warnings shall adequately warn of the hazard, Labels shall be permanently affixed to the equilarnent, and Labels required shall be suitable for the environrnent- NE W,,CY.1 r ANO NFFA -, " 1,1, 111 11, 11. 122-! A Design TemperaturefF) 94'F Max Amp Terno Ranae(la 97-95 am Current Carrying— ___ <4_ 310J5(Bg3-l(a)­­- -A C Max Output Current I 27A 690,8WI31i Max Output Cutrent - 1-25% 33A Overcurrent Protection(A) 40A I Racewav Fill adiustment Factor 1 100% 1 310,15(91B)fa3 Arripaciny Check I Per 69qAfqj(1i fa��­ 25-40A<50A Pass Ampacity Check 2 Per 690-8(8)(2) I'll ''Pass 50A*0.94A*1=47A>26.62A Pass All Exterior equipment is A minimum of Nema-R3 Rated All Interactive System(S-) Points of interconnection with other sources shall be marked at an accesible location at the disconnecting m,.eans as a power source and with the rated ac oUtput current and the norr-tinal operating AC voltage. Per.NEC 690-54 Disconnect is in cornpliance .230.72 SUPPly side disconncct adJacent to Msp Over (--urrent Protection Device is "Next size up` BaSed on Inverter Max'Olurn Continuous Outptut r c-urrent Rating 2017 NEC 240,4(B) -Afl ne7 cqLlif)f151eI1t Labelswill be placed locatec! adjacerrt to iri tire correct location Meter on cxrcric,­d, roffl Pe r 'Code N EC 690 6(13), 690.56(,­), & 690.531 In compliance .vith 230,71 J-Box not penctrating roo ("orp-birier box in compliance Per C'ocle NFW 70512 2 * 2 () A < 125 A *No isthi.,r loads to be added 3/8 IN MIN. TEXT In Case of Emergency Call Apply to Main Disconnect Solar Bear at 727-471-7442 Permartena sticker added to disconnec,t EC# EC13006630 3/16 IN MIN. TEX -All Fie ctrical rewire F"quipillcm Alai! be locatcd ator 'abovc Load Side tap v,111 171e done In %iciel Mem ( ofilho ocated on tile Pole '0;,� kmg, '�hafl fic e, '�k eal ho R,�, �Imll mid 'n1whi" 6,,t th", �m t, mmlr,!( Almkip�,,Sfuffl 1% -lod -di ,hq� lomm,-, „,oh ml-llumml Cap,t„! I cU­ Include required label for metailic raceways and condo is to -Subject PV Systems has been designed sheet E-1 per NE"C arfide 690,31(G )(3). to meet the requirments of the NEC 2017, Add required label to sheet E-1 per NEC article 705.10. and those set forth by the Florida Solar Include required label to sheet E-1 per NEC article 705.12(B) Energy Center Certification, Including Photovoltaic AC disconne-t shall be capable of being locked Maximum Number of Module Strings, in the open position per NEC article 705.22(6). Maximum number of modules per string, Photovoltaic AC Overcurrent orroection shall be located Maximum Output, Module Manufacturer and within 10 feet or the Point where condU(oOrS a= e connected to model number, inverter manufacturer and model ffie service per NEC 705,31. l_Et T I S DO NOT TOUCH TERN NA ON B AND LGAAAD Sif)ES M 9N THE Cyr CAN PxiStINON NEC 690.13 I a)rUCTORS, WiAlAaME Artkkf REWNEhEArAZEGN--J - �KkHT TURN RAPID SHUTDOWN SWITCH Td, THE "OFF POSITION TQ SHUT DOWN PV SYSTEM AND REDUCE, SHOCK HAZARD IN THE:: ARRAY. (ICE METER -RED BY A WC SYSTEM 705 12(B)(3) POWER SOURCE i OUTPUT CONNECTION DO NOT RELOCATE THIS OVERCURRENT DEVICE Figure 690,56(C)(1)(a) Label for PV Systems that -g Shut down the array and the conductors leaving the array "s DUAL POWER SUPPLY SOURCES: UTILITY GRID AND PV SOLAR ELECTRIC SYSTEM 0 Godwin Engineering and gg g, R 'I K1 I Design, LLC 1 N INVERTER OUTPUT CONNECTION:_ NNECTION: I * 360 8378 i DO NOT RELOCATE THIS Foxtail Loop OVERCURRENT DEVICE Pensacola, FL 32526 K no r,4� 4r D. Chad Godwin, PE OF A POWER SOURCE OUTPUT CONNECTION: ' had Jigodwineng.com wojv L 0 NOT RELOCADEVICE TE THIS OVERCURRENT A L ///// H I Ill 11U111 %A, an apt tca e. NEC 705,10 A permanent plaque or directory, denoting the location of all electric power source disconnecting means on or in the premises, be installed at each service equipment location and at the location(s) of the system disconnect(s) for all electric power production sources capable of being interconnected. One sign required for each PV system. Plpns Satisfy NEC 250,94 & NEC250.53(A)(2) I r, C 1, 1 d i n t 1-I ,,, labei below i I Customer Info: In Case of Emergency Call Solar Bear at 727-471-7442 EC #: EC13006630 PATRICIA & DAVID NEAMON 37609 NEW HORIZONS BLVIV' ZEPHYRHILLS, FL 33541 6101 Johns Rd, Ste Tampa, FL 33634 727-471-7442 1 Date: 2/28/2023 brawn by: AM Wevised by: M "M+ Rev Date: Inverter Type: Enphase 1Q8PLt­JS-72-2-US PV Panel: (22) SIL-370 HC Total Wattage: 8,14OW tic. histail \kill be done to Mae' flactUrcr S I ----VAffWJ Proposed MOUnting locations K2 Rail 12 some= ,T MAIN"', 8 -Splice Bar 60 Standoff w/ E-curb 40 K2 Mids 8 K2 Ends/End Cags I Roof Top 6x6 J- ox 2 K2 Ground Lugs 22 SIL-370 HC 22 Enphase IQ8PLUS-72-2-US I 60A Fused Disconnect 2 40A Fuses 2 20A 2P Breaker I Enphase Combiner Box I 125A Sub Panel Max Cantilever = Max Span * (1) 3 Zone I - Max Cantilever = 10.66" Max Span = 32" Zone 2e: Max Cantilever = 10.66" Max Span = 32" Zone 2n: Max Cantilever = 10.66" Max Span = 32" Zone 2r: Max Cantilever = 10.66" Max Span = 32" Zone 3e: Max Cantilever = 10.66" Max Span = 32" Zone 3r: Max Cantilever = 10.66" Max Span N Inverter Type: PV Panel: Racking: T*M�-W-mVige. Roof Type: Wind Load: r vam R-1 # Modules (22) Pitch- 12' Azimuth: 189' (22)Enphase IQ8PLUS-72-2-US (22) SIL-370 HC K2 8,140W DC TPO 8 to 20 Deg Use Standoff E-curbs PATRICIA & DAVID NEAMON 37609 NEW HORIZONS BLVD ZEPHYRHILLS, FL 33541 Plans satisfy zones B('- 15 10.7,1 histall will be done to Mallft1fiaCtUM- E C Godwin Engineering and C E Design, LLC 60 8378 Foxtail Loop Pensacola, FL 32526 0 E OF D. Chad Godwin, PE Chadggodwineng.com L wiff " 4 mi M M WAR, (WI 4 Tampa, FL 33634 727-471-7442 Tt4te: 2/28/2023 I WWI g,e: I I 11x1 7" S-IA 4 1 sy z o ?I v ji, 6'. A""y I 1L." 17- - JIL-4 5 0 L A IR DIRECT FROM THE SOURCE. -8. nt ro ca uch , _m1fab Primm, Dependable, durable, high-performance solar panels engineered for North American homeowners. 3�5_1 a Test Conditions STC Module Power (Pmax) Wp 370 Maximum powervoltage (Vpmax) V 34.95 Maximum power current (I pmax) A 10.60 Open circuit voltage (Voc) V 41.75 Short circuit current (Isc) A I1 25 Module efficiency % 20.2% Maximum system voltage (VDQ V 1000 Series fuse rating A 20 Power Tolerance Wis 0 to +10 Measurement conditions: STC 1000 W/m'. AM I.S . Temperature 25'C - NOCT 800 W/m'- AM 15 - Measurement uncertainty 5 3% Sun simulator calibration reference modules from Fraunhofer Institute, Electrical characteristics may vary by ±50% and power by 0 to +10W NOCT 276 32.48 &50 39.16 9.07 18.9% Module weight 19.5kg ±0.2kg 43tbs ±0,4[bs Dimensions (H x L x D) 1762 onto x 1037 rum x 35 mm 69.4 in x 40.8 in x 1.37 in Maximum surface load (wind/snow)" 5400 Pa rear load / 5400 Pa, front load 112,8 lb/ffl rear load / 112,8 flo/ft' front load Hail impact resistance a 25 rem at 83 km/h o I in at 51.6 mph Celts 120 Half cells - Si mono PERC 120 Haffcetls- Si mono PERC 9 busbar - 83 x 166 mm 9 bulbar - 3,26 x 6.53 in Glass 3.2 Nun high transmittance, tempered, 0.126 in high transmittance, tempered, DSM antireflective coating DSM anfireffective coating Cables and connectors (refer to installation manual) 1350 Tom, o 5.7 mm, MC4 from Staubb 53,15 in, o 0.22 in (12AWG), MC4 from Staubli Backsheet High durability, superior hydrolysis and UV resistance, multi -layer dielectric film, fluorine -free PV backsheet Frame Anodized Aluminum (Black) Bypass diodes 3 diodes-30SQ045T (45V max DC blocking voltage, 30A max forward rectified current) Junction Box UL 3730 Certified, IEC 62790 Certified, IP68 rated TEMPERATURE RATINGS I WARRANTIES Temperature Coefficient Isc +0.064 %PC Module product workmanship warranty 25 years — Temperature Coefficient Voc -018 %PC Linear power performance guarantee 30 years Temperature Coreffic,ent Pmax -0.36%rc z 97.1% end Ist yr z 91.6%end 12th yr NOCT (± 2*C) 45'C e 85,1% end 25th yr Operating temperature -40/+g5°C z. 82.6% end 30th yr ULC ORD C1703, UL1703, CEC listed, UL 61215-1/4-1/-2, UL 61730-1/-2, Modules Per Pallet: 26 or 26 (California) Product IEC 61215-1/-1-1j`-2­.IEC 61730-1/-2-", CSA C22.2#61730-1/-2, IEC 62716 Ammonia Corrosion; IEC61701:2011 Salt Mist Corrosion Certifed, UL Fire Rating: Type 2 Pallets Per Truck 34 or 32 (California) Factory IS09001:2015 Modules Per Truck 884 or 832 (California) A Warning, Read the Safety and Installation Manual for mounting specifications and before handling, installing and operating modules 12 year extendable to 25 years subject to registration and conditions outlined under "Warrantyat ... Certification in progress. PAN flies generated from 3rd party performance data are available for download at 69.4" [1762mm] E E 14" [356mm] 41.3" [1 050mm] 14" [356mm] a Hole (x4) G MA_ U 1.4' [35TnTI, to F�l X 4E 1 70.06" 53.15" [1350MM] ixc Cable Length F­ 2 Lle=� 7 0 Hole (x8) (D ci 1 2.4" [60mm] 8" SILFAS 50,"AR HNK 800 Cornwall Ave Bellingham WA 98225 USA T +1 360.569.4733 info@sitfabsotar.com 1770 Port Drive Burlington WA 98233 USA T +1 360.569.4733 240 Courtneypark Drive East Mississauga ON LST 2Y3 Canada T +1905,2551501 F +1905,696,0267 Slifab - SIL-370-HC-20210803 No, oprod,cdo, of any kind is allowed without permission. Data ­d s wbject to ­dffic,oion s w,thout otics, C Sillab Solar f,c 2021. Silfuh , a 1,,,do­k of Silfab Sala, Inc. n"ENPHASE 11 oil • s— &Tfl is our proprietary application -specific integrated circuit (ASIC) which enables the 55nm technology with high speed digital logic and has super -fast response times to cha _' oadS Anti grid A%rAntq, energy systems. ,M M" Part of the Enphase Energy System, 108 Series Microinverters integrate with the Enphase 10 Batt", Enphase IQ Gateway, and the Enphase App monitoring and analysis software, Connect PV modules quickly and easily to 108 Series Microinverters using the included Q-DCC-2 adapter cable with plug-n-play MC4 connectors. 108 Series Microinverters redefine reliability standards with more than one million cumulative hours of power -on testing, enabling an industry -leading limited warranty of up to 25 years. Q8 Series Microinverters are UL Listed as PV Rapid Shut Down Equipment and conform with various regulations, when installed according to manufacturer's instructions. @ 2021 Enphase Energy. All rights reserved. Enphase, the Enphase logo, 108 microinverters, and other names are trademarks of Enphase Energy, Inc. Data subject to change. IQ8SP-DS-0002-01-EN-US-2021-10-19 Easy to install Lightweight and compact with plug-n-play connectors Power Line Communication (PLC) between components Faster installation with simple two -wire cabling High productivity and reliability Produce power even when the grid is down More than one million cumulative hours of testing Class It double -insulated enclosure Optimized for the latest high- powered PV modules Microgrid-forming Complies with the latest advanced grid support Remote automatic updates for the latest grid requirements Configurable to support a wide range of grid profiles Meets CA Rule 21 (UL 1741-SA) requirements Commonly used module pairings' W 235-350 235-440 Module compatibility 60-cell/120 half -cell 60-cell/120 half -cell and 72-ce1l/144 half -cell MPPT voltage range V 27-37 29-45 Operating range V 25-48 25-58 Min/max start voltage V 30/48 30/58 Max input DO voltage v 50 60 Max DO current' [module Iscl A 15 Overvoltage class DC port If DO port backleed current mA 0 PV array configuration lx1 Ungrounded array; No additional DO side protection required; AC side protection requires max 20A per branch circuit Peak output power VA 245 300 Max continuous output power VA 240 290 Nominal (L-L) voltage/ranges V 240 / 211- 264 Max continuous output current A 1.0 1.21 Nominal frequency Hz 60 Extended frequency range Hz 50-68 Max units per 20 A (L-L) branch circUit4 16 13 Total harmonic distortion <5 Overvoltage class AC port III AC port backfeed current mA 30 Power factor setting 1.0 Grid -tied power factor (adjustable) 0.85 leading - 0,85 lagging Peak efficiency % 97.5 97,6 CEC weighted efficiency % 97 97 Night-time power consumption mw 60 Ambient temperature range -40°C to -600C (-40OF to +140°F) Relative humidity range 4% to 100% (condensing) DO Connector type MC4 Dimensions (HxWxD) 212 mm (8.3") x 175 mm (6,91 x 30.2 mm (1,21 Weight 1.08 kg (2.38 lbs) Cooling Natural convection - no fans Approved for wet locations Yes Acoustic noise at I m <60 dBA Pollution degree PD3 Enclosure Class 11 double -insulated, corrosion resistant polymeric enclosure Environ. category / UV exposure rating NEMA Type 6 / outdoor CA Rule 21 (UL 1741-SA), UL 62109-1, UL1741/IEEE1547, FCC Part 15 Class B, ICES-0003 Class B, CAN/CSA-C22,2 NO. 1071-01 Certifications This product is UL Listed as PV Rapid Shut Down Equipment and conforms with NEC 2014, NEC 2017, and NEC 2020 section 690.12 and C22.1-2018 Rule 64-218 Rapid Shutdown of PV Systems, for AC and DO conductors, when installed according to manufacturer's instructions. (1) No enforced DC/AC ratio. See the compatibility calculator at https://Iink.enphase.com/ module -compatibility (2) Maximum continuous input DO current is 10.6A (3) Nominal voltage range can be extended beyond nominal if required by the utility. (4) Limits may vary. Refer to local requirements to define the number of microinverters per branch in your area. IQ8SP-DS-0002-01-EN-US-2021-10-19 , e r,_ w okig v ", ar a v e .'"` l"s r r" - I - 11-24 t' C -41ZI-AM1-240-4 LISTED To learn more about Enphase offerings, visit e i .o T The h a <.. so,,rn.,,s-. fd 1"C' with Enphase lQ Gateway and integrated L€ E-MI cell, modem (included only with IQ Combiner 4C) consolidates interconnection equiloroent into a single enclosure and streamlines IQ r-nicroinverters and storage installations by providing a Consistent, pre -wired solution for residential applications. It offers Up to four 2-pale input circuits and Eaton BR series bulbar assembly. Includes IQ Gateway for cornmunication and control Includes Enphase Mobile Connect cellular modern (CELLMODEM M1-06-S1 -05), included only with IQ Combiner 4C Includes solar shield to snatch Enphase IQ flattery aesthetics and deflect heat Flexible networking supports wi-Fi, Ethernet, or cellular Optional AC receptacle available for PLC bridge Provides production metering and consumption monitoring Centered mounting brackets support single stud mounting supports bottom, back and side conduit entry Up to four 2-pole branch circuits for 240 VAC plug-in breakers (not Incli;ded) BOA total PV or storage branch circuits Durable NRTL-certified NEMA type 3R enclosure Five-year limited warranty Two years labor reimbursement program coverage included for both the IQ Combiner SKU's UL listed vv_" Enphase IQ Combiner 1 MODEL NUMBER IQ Combiner 4 (X-iQ-AM"r-24G-4j IQ Combiner 4 with Enphase IQ Gateway printed circuit board for integrated revenue grade PV production metering g (ANSI C12 20 +/- 0.5v) and consumption monitoring (+/- 2.5%). Includes a silver solar shieidto match the IQ Battery system and IQ System Controller 2 and to deflect beat. IQ Combiner 4C (X...IQ AM! 240-4C) IQ Combiner 4C with Enphase IQ Gateway envied circuit board for integrated revenue grade PV production metering (ANSI C12.20 +/-0.5i) and con wnridon monitoring (+/- 25 i)- Includes Enphase Mobile Connect cellular modern (CELLMODEM-101-06-SP-05), a plugandplay industrial -grade cell modern to, systems sup to 60 microviverters- (Available in the US, Canada, Mexico, Puerto Rico, and the US Virgin, islands, where there is adequate cellular service in the insta€lation area) Includes a silver solar shield to match the IQ Battery and IQ System Controller and to deflect Iseat- ACCESSORIES AND REPLACEMENT PARTS (not included, order separately) Ensemble Communications Kit includes COMMS KIT 01 and CELLMODEM-M 06 SP-05 with 5-Year Sprint data plan for COMM S-CELLMODEM-M1-06 Ensemble sites CELLMODEM Mi-06-SP'-05 4G based TE-Ml cellular modernwith 5-year Sprint data plan CELLMODEM-M1-06-AT-05 4G based LTE Mt cellular nodem with 5-Year AT&T data plait Circuit Breakers Supports Eaton BR210, BR215, BR220, BR230, BR240, BR250, and 3R260 circuit breakers. BRK-16A-2-240V Circuit breaker, 2. pole, 10A, Eaton BR210 BRK-15A-2-240V Circuit breaker, 2 pole, 15A, Eaton BR215 BRK-20A-2P-240V Circuit breaker, 2 pole, 20A, Eaton BR220 BRK-15A-2P-240V-B Circuit breaker, 2 pole,15A, Eaton BR215B with hold down kit support BRK-20A-2P-240V B Circuit breaker, 2 pole, 20A, Eaton BR220B with hold down kit support EPLC-01 Power line carrier (communication bridge pair), quantity - one pair XA-SOLARSHiELD-ES Replacement solar shield for IQ Combiner 4/4C XA-PLUG-120-3 Accessory receptacle for Power Line Carrier in IQ Combiner 4ATC (required for EPLC-0 E) XA- ENV -PCBA-3 Replacement IQ Gateway printed circuit board (PCB) for Combiner 4/4C X-iQ-NA-HD-125A Hold dawn kit for Eaton circuit breaker with screws ELECTRICAL. SPECCEfCATIONS Rating Continuous duty System voltage 120/240 VAC, 60 Hz Eaton BR series busbar rating 125 A Max. continuous current rating 55 A Max, continuous current r ating {input from lwodoragrg 64 A Max. fuse/circuit rating (output) 90 A Branch circuits (solar and/cur storage) Up to four 2-pale Eaton BR series Distributed Generation (DG) breakers only (riot included) Max. total branch circuit breaker rating (input) 80A of distributed generation / 95A with IQ Gateway breaker included Production metering CT 200 A solid core pre -installed and wired to IQ Gateway Consumption monitoring CT (CT 200-SPL IT) A pair of 200 A split core current transformers MECHANICAL. DATA ,..._....,_.r_...,._-....._................. ....,..,...w., Dimensions (WxNxi3j .. ..,��... _...................._............... 37.5 x 49 5 x 15 8 can (14 75" x 19.5 x 6 63"); Height is 2 06"(53,5 cm) with mounting brackets Weight 7.5 kg (16.5lbs) Ambient temperature range -40° C to +461 C (-401 to 1151 c) Cooling Natural convection, plus heat .shield Enclosure environmental rating Outdoor, NRTL-certified, NEMA type 3R, podycarbanate construction W re sizes 20 A to 50 A breaker inputs: 14 to 4 AWG copper conductors 60 A breaker branch input 4 to 1/0 AWG copper conductors Main lug combined output: 10 to 2/0 AWG copper conductors Neutral and ground: 14 to 1/0 copper conductors Always follow local code requirements for conductor sizing. Altitude To 2000 meters (6,560 feet) INTERNET CONNECTION OPTIONS Integrate d iNrFi 802.11b/g/n Cellular CELL MOD EM-M1-06-SP 05, CEL.LMODEM-M'1-06-AT-05 (4G based LTE-M1 cellular modem). Note that an Enphase Mobile Connect cellular modem is required for all Ensemble installations, Ethernet Cpt;onai, 802.3, Cat5E (err Cat 6) UTP Ethernet cable (riot Included) COMPLIANCE Comp;iance, IQ Combiner UL 1741, CAN/CSA C22.2 No. 1071, 47 ore, Part IS, Class B, ICES 003 Production rnet nng: ANSI C12.20 accuracy class 0.5 (PV production) Consumption metering: accuracy class 2.5 Compliance, IQ Gateway UL. 6060-1/CANCSA 222 No, 61010-1 To learn more about Enphase offerings, visit h� exo 2021 dYnpase, Energy. All rights reserved r AI a .e, the , na e cu, .Q Gorribi-er 4/4 r , ad L _ games are trademarks of E i r h se 8nergy, Irrc ) In subject to change 10 2' 202 MOUnting systems for solar technology ®1 I N $TRU CM 0 INS www everest-so!@rsystems.com Mounting systems for solar technology M NEW I:IRODtJ(VT w Part Number Description 4000019 CrossRail 44-X 166", Mill 4000020 CrossRail 44-X 166", Dark 4000021 CrossRail 44-X 180", Mill 4000022 CrossRail 44-X 180', Dark 4000051 RailConn Set, CR 44-X, Mill 4000052 RailConn Set, CR 44-X, Dark 4000067 End Cap, Black, CR 44-X owcwevere.'st CrossRail 44-X Product Sheet US01 10520 Subject to change Product Wuwations are exemplary and may differ from the original.