HomeMy WebLinkAbout23-591817yvw
Issue Date: 03/31/2023
REINSPECTION FEES: (c) With respect to Reinspection fees will comply with Florida Statute 553.80(2)(c) the
local government shall impose a fee of four times the amount of the fee imposed for the initial inspection or
first reinspection, whichever is greater, for each subsequent remspection.
Notice: In addition to the requirements of this permit, there may be additional restrictions applicable to this property that
may be found in the public records of this county, and there may be additional permit required from other governmental
entities such as water management, state agencies or federal agencies.
Complete Plans, Specifications add fee Must Accompany Application. All work shall be performed in
accordance with City Codes and Ordinances. NO OCCUPANCY BEFORE C.O.
NO OCCUPANCY BEFORE C.O.
CONTRACTOR SIGNATURE
W, 5 �71' IN
P
THOUT APPROVED INSPECTION
i I I i �
J11111''i'll 11111,111111 ffPi] ` 11 �' z I I I- I
813-780-0020 City of Zephyrhills Permit Application Fax-813-780-0021
Building Department
Date Received
Phone Contact for Permitting ( 813 �)413 7999
Owner's Name Debra Warren Owner Phone Number 989-233-8586
Owner's Acldress5i42 NOrthlake Dr��� Owner Phone Number
Foe Simple Titleholder Name Owner Phone Number
Fee Simple Titleholder Address
JOB ADDRESS 6642 North Lake Dr Ze h rhills. FG 33542 LOT # 20
SUBDIVISION PARCEL
(OBTAINED FROM PROPERTY TAX NOTICE)
WORK PROPOSED NEW CONSTR ADD/ALT SIGN DEMOLISH
El INSTALL REPAIR
PROPOSED USE SFR COMM OTHER
TYPE OF CONSTRUCTION BLOCK FRAME STEEL
DESCRIPTION OF WORK 6, 14094,3
BUILDING SIZE = So FOOTAGE 2253 HEIGHT
�ZBUILDING VALUATION OF TOTAL CONSTRUCTION
=ELECTRICAL AMP SERVICE PROGRESS ENERGY W.R.E.C.
=PLUMBING
=MECHANICAL VALUATION OF MECHANICAL INSTALLATION
= GAS ROOFING = SPECIALTY = OTHER
FINISHED FLOOR ELEVATIONS FLOOD ZONE AREA =YES NO
BUILDER COMPANY The �Home �Depot
SIGNATURE REGISTERED Y/N FEE CURREN Y/N
Address License #
ELECTRICIAN COMPANY
SIGNATURE REGISTERED FEE CIJR�REN_Y / N��
Address License #
PLUMBER COMPANY
SIGNATURE REGISTERED L_Z2N _J F CURREN Y/N
Z2j _Z2j X_L_j
Address License #
MECHANICAL COMPANY E
SIGNATURE E=== REGISTERED ;;; FEE CURREN Y 1 N�
Address License #
OTHERC__ COMPANY
SIGNATURE REGISTERED YIN FEE C.RREI1=;;;N=
Address License #
RESIDENTIAL Attach (2) Plot Plans; (2) sets of Building Plans; (1) set of Energy Forms; R-O-W Permit for new construction,
Minimum ten (10) working days after submittal date. Required onsite, Construction Plans, Stormwater Plans w/ Silt Fence installed,
Sanitary Facilities & 1 dumpster; Site Work Permit for subdivisions/large projects
COMMERCIAL Attach (2) complete sets of Building Plans plus a Life Safety Page; (1) set of Energy Fonns. R-O-W Permit for new construction.
Minimum ten (10) working days after submittal date. Required onsite, Construction Plans, Stormwater Plans w/ Silt Fence installed,
Sanitary Facilities & 1 dumpster. Site Work Permit for all new projects. All commercial requirements must meet compliance
SIGN PERMIT Attach (2) sets of Engineered Plans.
—PROPERTY SURVEY required for all NEW construction.
Directions:
Fill out application completely.
Owner & Contractor sign back of application, notarized
If over $2500, a Notice of Commencement is required. (A/C upgrades over $7500)
— Agent (for the contractor) or Power of Attorney (for the owner) would be someone with notarized letter from owner authorizing same
OVER THE COUNTER PERMITTING (copy of contract required)
Remote If shingles Sewers Service Upgrades A/C Fences (Plot/Survey/Footage)
Driveways -Not over Counter if on public roadways..needs ROW
813-780-0020 City of Zephyrhills Permit Application Fax-813-780-0021
Building Department
NOTICE OF DEED RESTRICTIONS: The undersigned understands that this permit may be subject to "deed" restrictions" which may be more restrictive
than County regulations, The undersigned assumes responsibility for compliance with any applicable deed restrictions.
UNLICENSED CONTRACTORS AND CONTRACTOR RESPONSIBILITIES: If the owner has hired a contractor or contractors to undertake work, they
may be required to be licensed in accordance with state and local regulations. If the contractor is not licensed as required by law, both the owner and
contractor may be cited for a misdemeanor violation under state law. If the owner or intended contractor are uncertain as to what licensing requirements
may apply for the intended work, they are advised to contact the Pasco County Building Inspection Division —Licensing Section at 727-847- 8009.
Furthermore, if the owner has hired a contractor or contractors, he is advised to have the contractors) sign portions of the "contractor Block" of this
application for which they will be responsible. If you, as the owner sign as the contractor, that may be an indication that he is not properly licensed and is
not entitled to permitting privileges in Pasco County.
TRANSPORTATION IMPACT/lUTILITIES IMPACT AND RESOURCE RECOVERY FEES: The undersigned understands
that Transportation Impact Fees and Recourse Recovery Fees may apply to the construction of new buildings, change of use in existing buildings, or
expansion of existing buildings, as specified in Pasco County Ordinance number 89-07 and 90-07, as amended. The undersigned also understands, that
such fees, as may be due, will be identified at the time of permitting. It is further understood that Transportation Impact Fees and Resource Recovery
Fees must be paid prior to receiving a "certificate of occupancy" or final power release. If the project does not involve a certificate of occupancy or final
power release, the fees must be paid prior to permit issuance. Furthermore, if Pasco County Water/Sewer Impact fees are due, they must be paid prior
to permit issuance in accordance with applicable Pasco County ordinances.
CONSTRUCTION LIEN LAW (Chapter 713, Florida Statutes, as amended): If valuation of work is $2,500,00 or more, I certify that 1, the applicant,
have been provided with a copy of the "Florida Construction Lien Law —Homeowner's Protection Guide" prepared by the Florida Department of
Agriculture and Consumer Affairs. If the applicant is someone other than the "owner", I certify that I have obtained a copy of the above described
document and promise in good faith to deliver it to the "owner" prior to commencement,
CONTRACTOWSIOWNER'S AFFIDAVIT: I certify that all the information in this application is accurate and that all work will be done in compliance with
all applicable laws regulating construction, zoning and land development. Application is hereby made to obtain a permit to do work and installation as
indicated. I certify that no work or installation has commenced poor to issuance of a permit and that all work will be performed to meet standards of all
laws regulating construction, County and City codes, zoning regulations, and land development regulations in the jurisdiction. I also certify that I
understand that the regulations of other government agencies may apply to the intended work, and that it is my responsibility to identify what actions I
must take to be in compliance. Such agencies include but are not limited to:
Department of Environmental Protection -Cypress Bayheads, Wetland Areas and Environmentally Sensitive
Lands, Watenf Wastewater Treatment.
Southwest Florida Water Management District -Wells, Cypress Bayheads, Wetland Areas, Altering
Watercourses.
Army Corps of Engineers -Seawalls, Docks, Navigable Waterways.
Department of Health & Rehabilitative Services/Environmental Health Unit -Wells, Wastewater Treatment,
Septic Tanks.
US Environmental Protection Agency -Asbestos abatement.
Federal Aviation Authority -Runways.
I understand that the following restrictions apply to the use of fill:
Use of fill is not allowed in Flood Zone W" unless expressly permitted.
If the fill material is to be used in Flood Zone "A", it is understood that a drainage plan addressing a
"compensating volume" will be submitted at time of permitting which is prepared by a professional engineer
licensed by the State of Florida.
If the fill material is to be used in Flood Zone "A" in connection with a permitted building using stem wall
construction, I certify that fill will be used only to fill the area within the stem wall.
If fill material is to be used in any area, I certify that use of such fill will not adversely affect adjacent
properties. If use of fill is found to adversely affect adjacent properties, the owner may be cited for violating
the conditions of the building permit issued under the attached permit application, for lots less than one (1)
acre which are elevated by fill, an engineered drainage plan is required.
If I am the AGENT FOR THE OWNER, I promise in good faith to inform the owner of the permitting conditions set forth in this affidavit prior to
commencing construction. I understand that a separate permit may be required for electrical work, plumbing, signs, wells, pools, air conditioning, gas, or
other installations not specifically included in the application. A permit issued shall be construed to be a license to proceed with the work and not as
authority to violate, cancel, alter, or set aside any provisions of the technical codes, nor shall issuance of a permit prevent the Building Official from
thereafter requiring a correction of errors in plans, construction or violations of any codes. Every permit issued shall become invalid unless the work
authorized by such permit is commenced within six months of permit issuance, or if work authorized by the permit is suspended or abandoned for a
period of six (6) months after the time the work is commenced. An extension may be requested, in writing, from the Building Official for a period not to
exceed ninety (90) days and will demonstrate justifiable cause for the extension. If work ceases for ninety (90) consecutive days, the job is considered
abandoned.
FLORIDA JURAT (F.S.
OWNER OR AGENT CONTRACTOR
A�ngdnd sworn to (or ffirmec) before me this t 11�1 i i to (or ffirmel) before me this
by Martm
Who is/are personally known to me or has/have produced Who is/are personally known to me or hi�oave produced
4s identification, as identification.
A I / Notary Public —
Commission Not__ _ V Commission
Public
printed or stamped Name of Notary typed, printed or stamped
Notary Public Notary of Florida
"! o
Notary Public State of Florida John H Christianson
Commission
'a 'a n A John H Christianson My Commission HH 337889
1
lilt My Commission HH 337889 EEIiExpires 12118/2026
Expires 12/18/2026
IWINOM ma&
Permit Number
Parcel ,liiNumber '
NOTICE OF COMMENCEMENT
State of Florida
County of PA&C-0
THE UNDERSIGNED hereby gives notice that Improvements will be made to certain real property, and In accordance with Section 713.13 of the
Florida Statutes, the following information is provided in this NOTICE OFCOMMENCEMENT,
1. Description of property (legal description): '2o
a) Street Uob) Address.
2.Generat description of fmprovementsc
3.Owner Information or Lessee information If the Lessee contracted for the Improvement.,
a) Name and address:. "A
b) Name and address of fee simple titleholder (if different than Owner listed above)
c) Interest in
4.Contractor Information
a) Name and address:
b) Te!ephone No,:
c)AmountofBond:
6.1-ender A
a) Name and address:
- b) Telephone No.:
7, Pers ons with in th e State of Florida des ignate d by Owner upon %0om notices or other documents may be served as provided by Section
713,13 (1) (a) 7, Florida Statutes;
a) Name and address:
b) Telephone No.: Fax No.: (optional)
addition to himself or herself, Ownerclesignates of
to receive a copy of the Lienors Notice as provided in Section 713.13 (1) (b), Florida Statutes.
b) Phone Number of Person or entity desfgnated by Owner:
9. Expiration date of notice of commencement (the expiration date may not be before the complation of construction and final payment to Hie
contractor, bu���#_date of recc p
WARNING TO OWNER: ANY PAYMENTS MADE BY THE OWNER AFTER THE EXPIRATION OF THE NOTICE OF COMMENCEMENT ARE
CONSIDERED IMPROPER PAYMENTS UNDET,-GH3PT-E",0.-.P-1TT 1. SECTIOV 713.13.1.STA DL
WINDOW SPECIFICATION SHEET -
Spec. Sheet #: F32407433
Sheet: 1
of 2
Customer: DEBRA WARREN
Job #: F32407433
Consultant:
David Wilson
Date: 03/18/2023
New Window
Existing Window
Hinge Locations,
Measurements
Grids
Product Options Labor Options
From outside,
Left to Right
Bays, Bows
Location
Color
Rough Opening
# of bars
# of bars
Csmnts, I PnL
use L, R or S
Glass
Mac Items
Hardware
Code
Screens
For doors use
E Mull
"S" = stationary or
W
Style Wraps
W5
z
Ca
(5
.2
J, -6
'X" operating
t:
Room Floor Code (Y/N)
Style Code Series Code
W
2:
�5
a- >
M 0 >
D, GlassPack: BF
1
LAUN 1st DH- N
DHC
6100
WH
WH
52
37 89
SiTandardWhite,
ALDER
STD, White, GlassPack: BFStandard
2
BED1 1st DH- N
DHC
6100
WH
WH
36
62 93
ALDER
STD, W GlassPack: BF
i3
8ED2 Tat DH- N
DHC
6100
WH
WH
36
62 98
Standardhite,
ALDER
STD, White, GlassPack: BF
4
HALL 1st DH- N
DHC
6100
WH
WH
36
37 73
Standard
ALDER
STD,White, TMP : Full, BF
5
BATH 1st DH- N
DHC
6100
WH
WH
25
37 62
Obscure Glass: Full,
ALDER
GlassPack: Standard
STD, White, GlassPack: BF
6
LrV 1st PW_ N
PWC
6100
WH
WH
72
14 86
Standard
ALDER
STD, White, GlassPack: SP
7
KITCH 1st Pw_ N
PWC
6100
WH
WH
72
14 86
Standard
ALDER
STD,its, GlassPack: BF
8
KITCH 1st DH- N
DHC
6100
36
62 98
Standard
ALDER
SPECIAL CONSIDERATIONS:
Permit Processing
Wrap Color
Interior Casing Type
Bay or Bow window:
Peatboard material (vinyl only -Birch or Oak)
1Bay Project Angle (30 or 45)
lBay Flanker Type (DH, SH, or Csmnt)
[Top, of window to soffit (inches)
It tied to soffit, color of soffit material
I have reviewed and agree with all the job specifications above and the
Construct Roof (Yes or No) *
Special Terms and Conditions on the following page
Garden Window:
Seatboard Material (vinyl only -White Pionite, Birch or Oak) I
WINDOW SPECIFICATION SHEET -
Spec. Sheet #: P32407433
Sheet: 2
of 2
Customer: DEBRA WARREN
Job #: F32407433
Consultant:
David Wilson
Date: 03/18/2023
New Window
Existing Window
Hinge Locations
Measurements
Grids
Product Options Labor Options
From outside,
Left to Right
Bays, Bows
Location
Color
Rough Opening
# of bars
# of bars
Csmnts, 1 Pni,
use L, R or S
Glass
Misc Items
Hardware
Code
Screens
For doors use
76 Mull
"S" = stationary or
Style Wraps
Z5
u- 25 7a
� M E
'
�2
V
'X" operating
L-
Room Floor Code (Y/N)
Style Code
Series Code lt
x
LU
5
6 >
>
STD, White, GlassPack: 3P
9
FAM 1st PW_ N
PWC
6100 WH
WH 72
14
Standard
ALDER
IE36
STD, White, GlassPack: BE
10
MBED 1st PW_ �N
PWC
6100 WH
WH 72
14 86
Standard
ALDER
STD, White, GlassPack: BE
11
MBED 1st DH- N
DHC
6100 WH
WH 25
62 87
Standard
ALDER
STD, White, GlassPack: BF
12
MBED 1st DH- N
DHC
6100 WH
WH 25
62 87
Standard
ALDER
Wrap Color
linterior Casing Type
IBay or Bow window:
eatboard material (vinyl only -Birch or Oak)
L-Y Project Angle (30 or 45)
1Bay Flanker Type (DR, SH, or Csmnt)
[fop of window to soffit (inches)
It tied to soffit, color of soffit material
Construct Roof (Yes or No)*
Garden Window:
1'eatboard Material (vinyl only -White Pionite, Birch or Oak)
SPECIAL CONSIDERATIONS:
Permit Processing
I have reviewed and agree with all the job specifications above and the
Special Terms and Conditions on the following page
I
-- V---',,!
�, `
1 6100 Double Hun \ cry
Non -Impact �immimma��
BCIS Home Log In User Registration Hot Topics ? Submit Surcharge. Stats & Facts ! Publications, Contact Us BCIS Site Map Links Search
ui c
irL�Product Approval
USER: Public User
Prodpct„Agproval Menem > Product or Application 5earph > AGplic ion List > Application Detail
FL #
FL5167-R37
Application Type
Revision
Code Version
2020
Application Status
Approved
*Approved by DBPR. Approvals by DBPR shall be reviewed and ratified by
the POC and/or the Commission if necessary,
Comments
Archived
Product Manufacturer
Simonton/Ply Gem Windows
Address/Phone/Email
5020 Weston Parkway
Suite 300
Cary, NC 27513
(800)542-9118 Ext413596
luanne.harris@cornerstone-bb.com
Authorized Signature
Luanne Harris
luanne.harris@cornerstone-bb.com
Technical Representative
Address/Phone/Email
Quality Assurance Representative
Address/Phone/Email
Category
Subcategory
Compliance Method
Certification Agency
Validated By
Referenced Standard and Year (of Standard)
Equivalence of Product Standards
Certified By
Luanne Harris
3948 Townsfair Way
Suite 200
Columbus, OH 43219
(614) 532-3596
luanne.harris@simonton.com
AAMA
1827 Walden Office Square
Suite 550
Schaumburg, IL 60173
(847)303-5664
webmaster@aamanet.org
Windows
Double Hung
Certification Mark or Listing
Fenestration and Glazing Industry Alliance (formerly AAMA)
American Architectural Manufacturers Association
5tandarA
AAMA 450
AAMA/WDMA/CSA 101/I.S.2 A440
AAMA/WDMA/CSA 101/I.S.2 A440
Y r
2010
2011
2008
Product Approval Method Method I Option A
Date Submitted 07/08/2021
Date Validated 07/12/2021
Date Pending FBC Approval
Date Approved 07/16/2021
Summary of Products
FL # Model, Number or Name
I Description
5167.1 07-09, 07-10 and 07-20
'1 Reflections 5500, PerfeXion Platinum Vinyl Double Hung
Limits of Use
Certification Agency Certificate
Approved for use in HVHZ. No
pdf
Approved for use outside HVHZ: Yes
FL51 7 R 7 C AC 07-Q9 n 7x76 PG65.p�df
Impact Resistant: No
4 R P 6 0. pAf
Design Pressure; N/A
i FL5167 R37 C CAC 07 09 QH 44x6R50.pdf
Other, 48x80 (+/-25 PSF), 56x84 (+/-25 PSF), 53x76 (+/-50
PSF), 36x63 (+/-50 PSF), 44x64 (+/-50 PSF), 47x71 (+/-50
0 R25 p
PSF), 37x84 (+/-60 PSF), 37x76 (+65/-70 PSF)
7 R5
4 R P - PAf
and 08- -1 - 0
Wajver.%df
p df
Quality Assurance Contract Expiration Date
12/13/2021
Installation Instructions
PAf
L 1 7 P37 TT TNn c,-
Verified By: Fenestration and Glazing Industry Alliance
(formerly AAMA)
Created by Independent Third Party:
Evaluation Reports
1 Created by Independent Third Party: Yes
. ............... ... . ........
5167.2 7-09, 07-10 and 07-20
i Reflections 5500, PerfeXion Platinum Vinyl Double Hung with
Transom
Limits of Use
Certification Agency Certificate
Approved for use in HVHZ* No
Approved for use outside HVHZ: Yes
1RG50 (ext._).p f
Impact Resistant: No
Design Pressure: +50/-50
W-LV-Qrp-df
Other:53x130
pdf
Quality Assurance Contract Expiration Date
04/19/2025
Installation Instructions
�onn
?-X—. Qdf
Verified By: Fenestration and Glazing Industry Alliance
(formerly AAMA)
Created by Independent Third Party:
Evaluation Reports
Created by Independent Third Party:
------ . ....
5167.3 07-09, 07-10 and 07-20
.. .... ... .. . .......
Reflections 5500, PerfeXion Platinum Vinyl Double Hung H-
Mulled Triple
Limits of Use
J Certification Agency Certificate
Approved for use in HVHZ: No
_ZLR-
Approved for use outside HVHZ: Yes
iRg-50 (9?i—t.5)-.Wf
Impact Resistant; No
Tripp_j6Dx7 R_
Resign Pressure: +50/-50
Other: 160x76,126x76
EQ50 (ext.5),p f
We _ive r p_df
Pdf
Quality Assurance Contract Expiration Date
i 04/19/2025
Installation Instructions
Twin -Tripe —
2 aft
—X.
Verified By: Fenestration and Glazing Industry Alliance
(formerly AAMA)
Created by independent Third Party:
Evaluation Reports
Created by Independent Third Party:
n
5167.4 7-09 �7-10 and 07-20
1 Reflections 5500, PerfeXion Platinum Vinyl Double Hung Triple
5167.9 143-17
Limits of Use
Approved for use in HVHZ: No
Approved for use outside HVHZ; Yes
Impact Resistant: No
Design Pressure: N/A
Other: 3602 (+/-30 PSF), 48x80 (+/-30 PSF), 5301 (+/-35
PSF), 44x63 (+/-35 PSF), 48x80 (+/-35 PSF), 36x63 (+/-45
PSF), 44x63 (+/-45 PSF), 2606 (+/-50 PSF) & 3604 (+/-50
PSF), 32x62 (+/-50 PSF)
5167A0 143-17
Limits of Use
Approved for use in HVHZ: No
Approved for use outside HVHZ- Yes
Impact Resistant: No
Design Pressure: N/A
Other: 96x80 (+/-25 PSF), 89x63 (+/-30 PSF), 73x63 (+/-35
PSF) & 72x74 (+/-45 PSF)
5167.11 143-35 (Two -Step Sill)
Limits of Use
Approved for use in HVHZ: No
Approved for use outside HVHZ: Yes
Impact Resistant. No
Design Pressure: N/A
Other: 44x63 (+/-25 PSF), 46x84 (+/-25 PSF), 36x72 (+/-30
PSF), 48x80 (+/-35 PSF), 52x71 (+/-35 PSF)
5167.12 43-35 (Two -Step Sill) and 43-50
(Three -Step Sill)
Limits of Use
Approved for use in HVHZ: No
Approved for use outside HVHZ; Yes
Impact Resistant: No
Design Pressure: +35/-35
Other: 73x111
Evaluation Reports
Created by Independent Third Party:
Profinish Contractor, Prol'inish Master, PerfeXion Contractor
Vinyl Double Hung
Certification Agency Certificate
&5_167 R 7 A 43-17 DH (E[n)_Z606 P-
EQ-50(2A.5L121
EL51_k7 R 43-1 (_Fjrj)_j2xU-.UjpAf
EL21E7-RSAC 43-17 DH (Elln-)-!Lx72--R3-Q-.p�Lf
fL51EZ_R2Z_L_CAS AlllZ_DWLin)-3Lx74 R5_0.Q�f
ELaj5Z_EjjCAC 4 -1? DM (Lin)_AAx�a �RP .p_df
20 —0. Off
fLaILZ_aaZ_L_CAC _A2zlZ_DHJLiti)-Aax-S-0 R-PG35
P d-f
1`1_5167 R3? C CAC 43 1? DH (ELinless)_3A04 R5Q.pdf
EL5_i67 R37 C �A� 43 17 [JH (finless)_Aax80 R3_5.p r
FL5167 R37 C CAC 4 -17 DH xrA P P(-.4r ptlf
R45,p�jf
FL51 Fin)lpdf
Quality Assurance Contract Expiration Date
12/11/2021
Installation Instructions
FL5167 R37 11 IN0096 4 - 7 DH 2Y-pdf
FL5167 R 7 11 IN0254 43- 17 DH I Y pLf
Verified By: Fenestration and Glazing Industry Alliance
(formerly AAMA)
Created by Independent Third Party:
Evaluation Reports
FL5167 _R37 AE_EvalReporU-NQ254-R7.p�df
Created by Independent Third Party: Yes
Profinish Contractor, Profinish Master, PerfeXion Contractor
Vinyl Double Hung T-mulled Twin
Certification Agency Certificate
pdf
P d-f
Pff
pdf
Quality Assurance Contract Expiration Date
04/22/2022
Installation Instructions
Of.
Verified By: Fenestration and Glazing Industry Alliance
(formerly AAMA)
Created by Independent Third Party:
Evaluation Reports
Created by Independent Third Party:
6100 VantagePointe, Asure, PerfeXion Silver Vinyl Double Hung
Certification Agency Certificate
Ulf
FL5167 R37 C CAC 43-35 DH 46x84-R25.&f
wff
PAf
Quality Assurance Contract Expiration Date
01/24/2026
Installation Instructions
Of
FL51Z
Verified By: Fenestration and Glazing Industry Alliance
(formerly AAMA)
Created by Independent Third Party:
Evaluation Reports
FL5167 R37 AE EvalRepo_rt-IND568-R4.p f
Created by Independent Third Partv: Yes
6100 VantagePointe, Asure, PerfeXion Silver Vinyl Double Hung
Twin with Transom
Certification Agency Certificate
X111-
E35.pdf
FL5167 R37 C CAC 43-50 DH TWIN w TRANSOM 73x111-
R35.pdf
Quality Assurance Contract Expiration Date
01/24/2026
Installation Instructions
FL51 m
2 _X. P_d_f
ttlttr«�
Tu/LU'2'f
LUCAS A. TURNER, P.E.
Lucas Turner
%ye
FL PE 58209
TURNER ENGINEERING
MODEL DESIGNATION:Simonton Double Hung Series 43-35 Vinyl Window 2021.03.03
S#3�'s.
='+s= Na' 582os `>ffi=
&
CONSULTING, INC.
MAXIMUM OVERALL NOMINAL SIZE: See Size Chart 15:75:54
r� sTAn �$
(COA # 29779)
2428 OLD NATCHEZ TRACE
-06'00'
TRAIL, CAMDEN, TN 38320
DESIGRATIN See Size Chart
N PRESStiRE
Y?;
�r {gg�y i*''
PH, 9ai-380-1574
USABLE CONFIGURATIONS: X
X
GENERAL DESCRIPTION- The head, sill, and side jambs are extruded PVC. The wall thickness
through which the anchor screw penetrates is a minimum of 0.142".
SIZE CHART
OVERALL SIZE l
WIDTH
HEIGHT
DP RATING
"W
44"
63"
84"
±25 ESE
46"
36"
72"
±30 PSF
48"
80"
71"
±35 PSF
52"
1---"W" MAX. OVERALL FRAME WDTH
TABLE is INSTALLATION FASTENERS TABLE
ID SUBSTRATE TYPE
ANCHOR TYPE
MIN. EMBED MIN EDGE
DISTANCE
A CONCRETE (2 KSI MIN.)
3/16" DW TAPCON
I-1/2" 1-i/8"
B HOLLOW OR GROUT -FILLED CMU
3/16" NW TAPCON
? 2"
117 PCE MIN.
C 2X FAIN. SOUTHERN PINE WOOD
= G0.55
3/16" IT'W TAPCON
1-3/8" 7/8"
D 2X MIN. SOUTHERN PINE WOOD
#10 WOOD SCREW
1-3/8" 7/8"
G=ME
?6 GAUGE 0.060 MIN. STEEL
E
1fl-i6 !TW TIERS
THREAD 3/2"
STUD 33XSI YIELD MIN.
SELF -DRILLING SCREW
FFULL
i 8 ALUM. 6063-T5 MIN. OR
I
10 GRADE 5 SFLF-TAPPING
FULL THREAD 7/2"
1 8" STEEL 36 KSI MIN.
DRILLING SCREW
SILICONE CAUL(
(EXT. PERIMETER)
SUBSTRATES BY OTHERS
1/4" MAX. SHIM SILICONE CAULK
(INT. PERIMETER)
HEAD
1/4" MAX. SHIM
SILICONE CAULK
SILICONE CAULK SUBSTRATES BY OTHERS
1 SILL
REVISIONS:
ADDED MIN. EDGE DIST, NOTE.
ADDED NOTES 17 & 18 - AAMA 800
ADDED MULTIPLE SUBSTATES
UPDATED TO 7TH EDn1ON (2020) Me
MIN. EMBED.
SEE TABLE i
INSTALLATION FASTENERS
SEE TABLE 1 "\
MIN. EDGE DIST,
SEE TABLE 1
SUBSTRATES
BY OTHERS
SILICONE CAULK
(INT. PERIMETER)
1/4" MAX. SHIM
SILICONE CAULK
(EXT. PERIMETER)
JAMB
NOTES:
I. THIS INSTALLATION HAS BEEN EVALUATED FOR USE IN LOCATIONS ADHERING TO THE FLORIDA BUILDING CODE OUTSIDE THE HVHZ, AND WHERE PRESSURE REQUIREMENTS AS
DETERMINED BY ASCE 7 MINIMUM DESIGN LOADS FOR BUILDINGS AND OTHER STRUCTURES DO NOT EXCEED THE DESIGN PRESSURE RATINGS HEREIN.
2. ALL INTERIOR AND EXTERIOR PERIMETER SURFACES Of THE WINDOW MUST BE CAULKED.
3. ANCHOR TYPE, SIZE, SPACING, EMBEDMENT, AND EDGE DISTANCE SHALL BE AS SPECIFIED IN THESE DRAWINGS. USE APPROPRIATE ANCHORAGE FROM TABLE i ACCORDING TO
SUBSTRATE TYPE. A MINIMUM CENTER -TO -CENTER SPACING OF 3" SHALL BE MAINTAINED BETWEEN ALL ELCO ULTRACONS IN ANY DIRECTION.
4. ANCHOR EMBEDMENT TO SUBSTRATE SHALL BE BEYOND WALL DRESSING OR STUCCO. FOR MASONRY OPENINGS WITH WOOD BUCKS LESS THAN 1-112" THICK, EMBEDMENT SHALL BE
BEYOND WOOD BUCKS, IF USED, AND INTO MASONRY SUBSTRATE. WOOD BUCKS WITH MASONRY ARE OPTIONAL.
5. WOOD OR MASONRY OPENINGS, BUCKS, AND BUCK FASTENERS, BY OTHERS, SHALL BE PROPERLY DESIGNED AND INSTALLED TO TRANSFER WIND LOADS TO THE STRUCTURE.
6. THE RESPONSIBILITY FOR SELECTION OF SIMONTON PRODUCTS TO MEET ANY APPLICABLE LOCAL LAWS, BUILDING CODES, ORDINANCES, OR OTHER SAFETY REQUIREMENTS RESTS
SOLELY WITH THE ARCHITECT, BUILDING OWNER, OR CONTRACTOR.
7. SHIMS ARE REQUIRED WHERE GAPS OF GREATER THAN 1/16' EXIST BETWEEN OPENING AND FRAME, MAX. SHIM STACK IS 1/4'. SHIMS SHALL BE LOAD -BEARING AND CAPABLE OF
TRANSFERRING LOADS TO THE SUBSTRATE.
8. WHEN USED IN AREAS REQUIRING IMPACT PROTECTION, THIS PRODUCT REQUIRES THE USE OF APPROVED IMPACT RESISTANT SHUTTERS OR OTHER EXTERNAL PROTECTION.
9. SEALING AND FLASHING BY OTHERS SHOULD BE APPLIED USING THE ASTM E 2112 METHODOLOGY APPROPRIATE FOR THE OPENING INTO WHICH THE PRODUCT IS BEING INSTALLED.
OVERALL WATER PENETRATION RESISTANCE OF THE INSTALLED PRODUCT IS NOT ADDRESSED IN THIS DRAWING AND is THE RESPONSIBILITY OF OTHERS.
I0, GLAZING SHALL COMPLY WITH ASTM E 1300.
lL ALL FASTENERS PENETRATING INTO PRESSURE TREATED WOOD SHALL BE CAPABLE OF PREVENTING CORROSION DUE TO REACTION WITH PRESSURE TREATMENT CHEMICALS. ANY
DISSIMILAR MATERIALS THAT COME INTO CONTACT SHALL BE PROTECTED TO PREVENT REACTIONS IN ACCORDANCE WITH CODE REQUIREMENTS.
12. A WIND LOAD DURATION FACTOR CD = 1.6 WAS USED FOR THE ANALYSIS Of WOOD SCREWS ONLY.
13. PRODUCTS SHALL BE CONSTRUCTED AS SPECIFIED IN TEST REPORTS ATI-B6470.01-109-47, ATI-B6472.01-109-47 AND ATI-B6473.01-109-47.
14. DESIGNATION 'X' AND "0" STAND FOR THE FOLLOWING: X: OPERABLE PANEL - 0: FIXED PANEL.
15. USE A BACKER ROD ON ALL JOINTS >3/4` DEEP AND/OR WIDER THAN 1/4'. FINISHED CAULK JOINT SHOULD BE A MINIMUM OF 3/8' DEEP.
Ms FINISH: SiMONTONe ...Bv........
This document Is the property of Simonton Windows, which Dimensional Tolerances µ, s DRAWN 8'
retains all propnstIIry and other rights to Its subject mutter ,_rrcePr„g5„ypTEp !I lee. Otherwise Si cf'd ° T.D.D.
This document Is provided to the recipient on the expressed ALLOY E< TEMPER: I (, h A cnue CHECKED
;ondition that it is not to be disclosed, reproduced in whole or I cnnsb—, WV 26415
part, nor used In conjunction with the design, manufacture or Decimals Angles SCALE: EFT: APPRYD
repair of goods for anyone other than Simard- Windows
without its consent. This restric#Ion does not Unlit the URFACE AREA: .X t .03 FIT I of I
recipient's rights to utilise infarmafion contained in this .XX t .01 0' 30 min. SERIES:
document which is properly obtained from another source. ,XxX t .005 43-35 DOUBLE HUNG
MODEL DESIGNATION: Simonton Double Hung Series 43-35 Vinyl Window
MAXIMUM OVERALL NOMINAL SIZE: See Size Chart
DESIGN PRESSURE RATING:. See Size Chart
USABLE CONFIGURATIONS: -X
X
GENERAL DESCRIPTION: The head, sill, and side jambs are extruded PVC. The wall thickness
through which the anchor screw penetrates is a minimum of 0.070'.
0
cc
�-- -W- MAX. OVERALL FRAME WIDTH —1
SIZE CHART
OVERALL SIZE
DP RATING
WIDTH HEIGHT
V, -H-
46'
84"
±25 PSF
4 - 63'
36"
72'
±30 PSF
48"
80'
±35 PSF
52" 71"
SILICONE CAUL4
2X BUCK
rl-,\ SILL
NO P.E. SEAL REQUIRED
INSTALLATION SUPPORTED
BY AAMA TEST REPORTS
REMSIONS:
UPDATED SIZE PER TEST REPORT #89924.01,
EM
1 5d4N. EDGE DISTANCE NOTE I r.W 1 6/16/15 3; 1 = —2 & 13 - AAMA ROD. I LMH 1 11/09/17
SILICONE 2X BUCK
CAULK
SILICONE CAULK
SILICONE
0 lZ4-ICMAX. SHIM
MAX. SHIM
31LICONE CAULK
HEAD
Itmam
#8 X 2 1/2" MIN, WOOD
SCREW WITH 1.50" MIN.
EMBEDMENTINTO WOOD
MIN. EDGE DIST., SEE NOTES.
Sfl Irnklc- 'Al 11
(�r) JAMB
NOTES: 1.4/
I , This installation has been evaluated for use in locations adhering to the Texas & Florida Building Codes and where pressure requirements as determined by
ASCE 7 Minimum Design Loads for Buildings and Other Structures do not exceed the design pressure ratings herein, for use outside the H.V.H.Z.
2. All exterior perimeter surfaces of the window must be caulked. Interior caulking is optional unless noted otherwise.
3. Anchors shall be as specified and spaced as shown. Anchor embedment to base material shall be beyond wall dressing or stucco and into wood.
4. The responsibility for selection of Simonton products to meet any applicable local laws, building codes, ordinances, or other safety requirements rests
solely with the architect, building owner, or contractor.
S. Shims are optional. Max. shim stack is 1/4",
6. Wood bucks (by others) must be engineered and anchored properly to transfer loads to the structure.
7. When used in areas requiring impact protection this product REQUIRES the use of approved impact resistant shutters or other external protection,
8, Flashing should be applied using the ASTM E 2112 methodology appropriate for the opening into which the window is being installed.
9. Installation screws must be at least 3/4" from the edge of the wood,
10. Installation screws may be placed in the interior or exterior track of the jamb. Screws should be flush with the vinyl.
11, Glazing shall comply with ASTM E 1300,
1 2,Use 100% pure silicone caulk compliant with AAMA 808 Section 5 - Sealant Specifications for use with Architectural Fenestration Products. Make sure
surfaces are completely free from all old caulk, damaged wood, wood fibers, grease, oil dirt, rust, mold or similar contaminants. Vacuum and clean
opening surfaces completely. A fully primed surface is recommended, but not required. Cleaning of all surfaces should be done the same day of which the
silicone caulk is to applied, For more details visit Simontomcom.
I 3,Caulk application: recommended air and surface temperatures at the time of application are to be between 40 and 90 degrees F. Insure all contact
surfaces are clean and dry including the new winclow(s). Use a backer rod on all joints >3/4" deep and/or wider than 1/4". Finished caulk joint should be
a minimum of 3/8" deep and make full contact with both the new window and structural opening surfaces. Silicone caulk should be forced into joint or
compressed to assure full contact on both surfaces and to expel any air pockets.
DISCLOSURE 5MIEMENT
This document is the property of Simonton, Vfindow% which
retain. .91 proprietary and other rights t. Its subject matter.
This document Is p,.,ld.d to the recipient an the -pressed
dition that It 1s not to be disclosed, reprod .. d In whole .
port, nor ..d in conjiumtin with the d-19h, manufactre or
repair of goods for anyone other than Simonton Windows
without It. consent. This restriction does not limit the
racIplart'. siqhts to ufilk. information contained In this
document which is properly obtained from another source.
Dirrion.land Tolroru,-
SIMONTON'
0
Unless Otherwise Specified
. I I . . w I
I C-h— A--
P—sb.., WV 26415
Decimals Angles
x .03
.xx t .01 0- 30 mi..
SERIES:
=X ± D05
43-35 DOUBT
3/11/22, 10:21 AM Florida Building Code Online
6100 Picture Window
nl,
Non -impact
mii'.amwa Km =I- 1=11-3371
BCIS Home Log In User Registration Hot Topics Submit Surcharge : Stats & Facts Publications Contact Us i BCIS Site Map Links Search
Product Approval
USER: Public User
Product Approval __M_enu > Product or Application Search > ApplicationList> Application Detail
FL #
FL5177-R35
Application Type
Revision
Code Version
2020
Application Status
Approved
*Approved by DBPR. Approvals by DBPR shall be reviewed and ratified by
the POC and/or the Commission if necessary.
Comments
Archived
Product Manufacturer
Simonton/Ply Gem Windows
Address/Phone/Email
5020 Weston Parkway
Suite 300
Cary, NC 27513
(800) 542-9118 Ext 413596
luanne,harris@cornerstone-bb.com
Authorized Signature
Luanne Harris
luanne.harris@cornerstone-bb.com
Technical Representative Luanne Harris
Address/Phone/Email 3948 Townsfair Way
Suite 200
Columbus, OH 43219
(614) 532-3596
luanne.harris@simonton.com
Quality Assurance Representative
AAMA
Address/Phone/Email
1827 Walden Office Square
Suite 550
Schaumburg, IL 60173
(847) 303-5664
webmaster@aamanet.org
Category
Windows
1�tl
Subcategory
Fixed
Compliance Method
Certification Mark or Listing
Certification Agency Fenestration and Glazing Industry Alliance (formerly AAMA)
Validated By Fenestration and Glazing Industry Alliance (formerly AAMA)
Referenced Standard and Year (of Standard) Standard
AAMA 450
AAMA/WDMA/CSA 101/l.S.2/A440
AAMA/WDMA/CSA 101/1.&2/A440
Equivalence of Product Standards
Certified By Florida Licensed Professional Engineer or Architect
fLaIZZ R35 Eq= Equivalency Le ter FL 177 5 pdf
Year
2010
2008
2011
https://floridabuilding.org/pr/pr�_app_dtf.aspx?param=wGEVXQwtDqtQclh%2bCtWN65AxLolopGhXIIFzX42RxQVSnjvE9RSTSQ%3d%3d 1/6
MIr :�■ MUFMA]
Impact Resistant: No
Design Pressure: N/A
Other- 96x72 (+/-30 PSF), 96x63 (+/-35 PSF), 74x63 (+/-50
PSF), 80x48 (+/-55 PSF)
5177A5 143-17 (Sunroom)
Limits of Use
Approved for use in HVHZ: No
Approved for use outside HVHZ. Yes
Impact Resistant: No
Design Pressure: N/A
Other: 74x63 (+/-50 PSF), 80x48 (+/-55 PSF), 96x63 (+/-35
PSF), 9602 (+/-30 PSF)
5177A6 143-35
Limits of Use
Approved for use in HVHZ: No
Approved for use outside HVHZ: Yes
Impact Resistant: No
Design Pressure. N/A
Other: 9602 (+/-40 PSF), 74x63 (+/-50 PSF), 80x48 (+/-50
PSF)
5177A7 143-35
Limits of Use
Approved for use in HVHZ: No
Approved for use outside HVHZ: Yes
Impact Resistant: No
Design Pressure, +50/-50
Other:109x72
5177.18 143-35
Limits of Use
Approved for use in HVHZ: No
Approved for use outside HVHZ: Yes
Impact Resistant: No
Design Pressure- +35/-35
Other:73x1I1
5177.19 143-40
EL5177 R35 —CCAC 43-17 PW (Fin) 96x72 C -PG30.pjIF -j-
�-R 5�pgif
Quality Assurance Contract Expiration Date
12/07/2024
Installation Instructions
FL5177 R IN $A 4117 MAI I Y pCif
. plf
Verified By: Fenestration and Glazing Industry Alliance
(formerly AAMA)
Created by Independent Third Party:
Evaluation Reports
ELjj773j5_AE fv IR -_4,p
Created by Independent Third Party: Yes
Prol'inish Contractor, PerfeXion Contractor Vinyl Fixed Window
for Sunrooms
Certification Agency Certificate
R55 pdf
EL21ZZ—Ras -L—CAS —la:!Z-EIULin)-Z4x63_R5O,�
6x72W-PQ.pdf
pdf
Quality Assurance Contract Expiration Date
12/07/2024
Installation Instructions
Off
Verified By: Fenestration and Glazing Industry Alliance
(formerly AAMA)
Created by Independent Third Party:
Evaluation Reports
FL5177 R35 AE PER7509 SS.pdf
Created by Indecendent Third Partv: Yes
6100, Asure, PerfeXion Silver Vinyl Fixed Window
Certification Agency Certificate
pff
aft
fL5177 R35 CA 43-35W p_d f
Quality Assurance Contract Expiration Date
09/10/2026
Installation Instructions
FL51:/L7 _P311 _IN04 4 �-PW �2X&ff
Of
Verified By: Fenestration and Glazing Industry Alliance
(formerly AAMA)
Created by Independent Third Party:
Evaluation Reports
EL5177—R35—AE EvalRP.p ort-IN009 -R4.p f
Created by Independent Third Party: Yes
6100, Asure, PerfeXion Silver Vinyl Fixed Window Triple
Certification Agency Certificate
&21ZZ_RILL_CAC 43 35 PW Triple-10x7 �-PSQ qdf
Quality Assurance Contract Expiration Date
01/25/2026
Installation Instructions
p-le —2X p,0-f
Verified By: Fenestration and Glazing Industry Alliance
(formerly AAMA)
Created by Independent Third Party:
Evaluation Reports
Created by Independent Third Party:
6100, Asure, PerfeXion Silver Vinyl Fixed Window Twin with
Transom
Certification Agency Certificate
FL5177 R35 C CAC 43-35 PW Twin w Tran m-7 xill-
R35.P-d1f
Quality Assurance Contract Expiration Date
01/25/2026
Installation Instructions
FL5177 R35 II IN0355 43 35 PW Twin w Transom 2X.pdf
Verified By: Fenestration and Glazing Industry Alliance
(formerly AAMA)
Created by Independent Third Party:
Evaluation Reports
Created by Independent Third Party:
Reflections 5050/5300, 6100, PerfeXion Gold, 4500 Vinyl Fixed
Window
https:llfloridabuilding.org/prlpr�_app_dti,aspx?param=wGEVXQ\,vtDqtQclh%2bCtWN65AxLolopGhXllFzX42RxQVSnjvE9RSTSQ%3d`/`3d 5/6
NO P.E. SEAL REQUIRED
MODEL DESIGNATIQLNL
Simonton Series 43-35 Vinyl Fixed Window
INSTALLATION SUPPORTED
` r
LAA—XIUIJ—M-Pff-R-A-LL-PLQM—INAL-27—F,,
See Size Chart
BY AAMA TEST REPORTS
-2
aR
4 VPDATED Na Es AND Gu9EP
HE ION PRESSURE RAflN
See Size Chart
5m ADDED GLAZING DETAILS,
USABLE C6NFI219A-RD-N—S:
0
6 COARGED SASH -FRAME i7ff
2rs — 'RE
7 ADDED MIN, EDGE DJST, 1401
FERAL DESGitEAT#6J'
The head, sill, and side jambs are extruded PVC, The wall thickness
through which the anchor screw penetrates is a minimum of 0,070",
SIZE CHART
_3VERALL SIZE
VA D TH HEIGH f DP RATING
.Vr
96' I 72' ±40 PSF
7r 6S ' 80' 48" 1 50 PSF
d-1, I.
; off PP,I.t
me,pirnt's dot. U, otitis. in Air x�
de".w,t Mich I. properly bt.1-d Y_
SILICONE 2X SUCK
CAULK
SILICONE CAUILK
K 114° MAX, S441M
HEAD_
�JIJ 4X SCALE
41 il if
T MAX, SHIM
SILICONE CAULK
SILICONE
CAULK
2X BUCK
SILL
4X SCALE
DATF-1,
TGGI
SILICONE CAULK
1/4' MAX, SHOii
2X BUCK-, 0 X 2 1/2- MIN, WOOD
SCREW WTH 1.50 ' MIN,
EMBEDMENr INTO WOOD
MIN, 00E, DIST., SEE NOIES
SILICONE CAULK
JAMB
V SCALE
NQLF—S
1, This instalinthin has been evaluated for Use in locations adhering to the Florida Building Codes and where pressure
requirements as determined by ASCE 7 Minimum Design LoGd5 for Buildings and Other Structures do not exceed
the design pressure ratings herein, for use outside the KV,K1
2, Ali exterior perimeter surfaces of the window must be caulked, Interior caulking is optional unless noted otherwise,
3. Anchors shall be as specified and spaced as shown. Anchor embedment to base material shal; be beyond wall
dressing or stucco and into wood,
4, The responsibility for selection of Simonton products to meet any applicable local lows, building codes, ordinances,
or other safety requirements rests solely with the architect, building owner, or contractor.
5. Shims are optionoL Max. Shim stock is 1/4',
6, Wood bucks (by others) rnust be engineered and anchored properly to transfer loacls to the structure.
7. When used in areas requiripra impact protection this product REQUIRES 'he use of approved jrrpact resistant
shutters or other external protection,
8- Flashing should be applied using the ASTM E 2112 methodology appropriate for tho opening into which the window
is being installed.
9. Installation screws must be at least 3/4" from (lie edge of fie wood.
10Glazing shall comply with ASTIA E 1300-04,
—1—
;Mersi—I Tolen,vo SIMONTON'
Otbw.;U _$2jdfTA 00 r, a I . I
:Xp,' ALLOY a EMPER: I Alc-1
antWv2fA 15
SCALE:
zK'"
EET
tb. SURFACE AREA:.. X 1.03 FIT rv, I
to this XX ± ^01 0' 30 Y,o, :.ERJL5`
n.— 11 XXX ± .005 43-35 Lq�E F
2X BUCK INSTALLATION
MODEL DESIGNATION:
MAXIMUM OVERALL NOMINAL SIZE:
DESIGN PRESSURE RATING:
USABLE CONFIGURATIONS:
GENERAL DESCRIPTION:
6' MAX.
Simonton Series 43-35 / 43-40 Vinyl Fixed Window
See Size Chart
See Size Chart
The head, sill, and side jambs, are extruded PVC. The wall thickness
through which the anchor screw penetrates is a minimum of 0.070`.
14-1/ " D.C. <
MAX, TYP, 6' MAX. -�—J '
so
17
0
11011
cE
ij
LONG SIDE `W" MAX. OVERALL FRAME WIDTH
SIZE CHART
OVERALL SIZE
WIDTH
I HEIGHT Did RATING
"Wo
"H"
96"
72"
0 PSF
74"
63"
±50 PSF
80"
-1
48"
*WIDTH AND HEIGHT CAN BE TRANSPOSED
3/02/2021
A. TURNER, P.E.
ysIV
LUCAS
F1 PE 58201
Lucas Turner
No 582
#
TURNER ENGINEERING &
2021 .0108
chin ."Y=
=X5 -gat
CONSULTING, INC.
12:08:00
�ok
(COA # 29779)
In, OR
2428 OLD NATCHEZ TRC TRL
CAMDEN, TN 38320
-06'00'
PH. 941-380-1574
'Nowl
REVISIONS; IREVISED le'd DATE:
1 2 .D.D. 1 11/27/11 1
3 1 UPDATED NOTES 10 & 13, ANCHOR SIZE LMH 1 04/12/18 d
f_
----------- ------- -------- f 1 4 JUP0ArEDF0NTH EDuFION(2o20)F5C MH 03/02/2I
L
IN WOOD BUCK
CONCRETE/MASONRY (BY OTHERS)
1/4`0 TAPCON ANCHOR (BY OTHERS) SILICONE CAULK
WITH I" MEN. EMB. (INT. PERIMETER)
OTHERS)
SILICONE
NT ,
INTO CONCRETE (SEE CONCRETE/MASONRY 4�' MAX.
X SHIM
M
NOTE 10 ED JF (BY OTHERS) 1/4`0 TAPCON ANCHOR 6V4
IT WOOD) P OTHERS)
HE �
WITH ill MIN. EMB. BY 0 THEIR 'S I
X I W INTO CONCRETE (SEE
BUCK NOTE 10 FOR WOOD)
SILICONE CAULK (BY OTHERS)
l EXT. PERIMETER)
SILICONE CAUL
(INT. PERIMETER)
1/4 " MAX. SHIM (SILICONE CAULK
IBY OTHERS) EXT,PERIMETER)
4T 43-40 JAMB
3-40 HEAD
1/4" MAX. SHIM
(BY OTHERS)
SILICONE CAULK
(INT. PERIMETER)
IX WOOD BUCK
SILICONE CAULK IBY OTHERS)
(EXT. PERIMETER)
CONCRETE/MASONRY
1/4`0 TAPCON ANCHOR (BY OTHERS)
WITH V MIN. EMB.
INTO CONCRETE ( SEE 1 43-40 SILL
NOTE 10 FOR WOOD)
1/4- MAX. SHIM
1/4"0 TAPCON ANCHOR
(BY OTHERS)7
WITH 1,25" MIN. EMB.
INTO CONCRETE ISEE
10 FOR WOOD)
SILICONE
SILICONE CAULK
SILICONE CAULK
(INT. PERIMETER)
(EXT. PERIMETER)
4NurE
IX WOOD BUCK
(BY OTHERS)
CONCRETE/MASO lA NRY
by
(BY OTHERS)
43-35 ANCHORAGE
NOTES: HEAD/JAMB/SILL
I- This installation has been evaluated for use in locations adhering to the Florida Building Code and where design pressure requirements as determined by ASCE 7 Minimum
Design Loads for Buildings and Other Structures do not exceed the design pressure ratings listed raced,
2. For installation where the sub -buck is less than 1 1/2" (FBC chapter 17 Anchorage Methods) Tapcon type concrete anchors must be used and the length must be such that
a minimum I' embedment of the Tapcon into the concrete or concrete block is obtained, unless otherwise noted. Anchors should be a minimum of 2" from the edge of
the concrete, hollow block CMU, or concrete block.
3. All interior and exterior perimeter surfaces of the window must be caulked.
4. Adjust Tapcon
anchor locations, if necessary, to maintain a minimum of 2.0" clearance from mortar joints.
1. When The optional head expanders are used, the INSTALLER MUST ADJUST the anchor lengths to maintain the required minimum embedment into the substrate.
6.
re shall be specified and spaced as shown. Anchor embedment to base material shall be beyond wall dressing or stucco and into wood or concrete,
Wood our', (by others) must be engineered and anchored property to transfer loads to the structure. Bucks shall extend beyond interior face of frame such that full
SH".rt of the frame is provided.
8. Follow ITW Tapcon anchoring Instructions.
9. The responsibility for selection of Simonton Products to meet any applicable local laws, building codes, ordinances, or other safety requirements rests solely with the
architect, building owner, or contractor.
l(u For wood buck substrates, use Al2 wood screws with 1 1/2" min, embedment into wood, unless otherwise noted. Screws should be a minimum of I" from the edge of
the wood.
11, A. Concrete compressive strength = 3000 PSI at 28 days -B. Concrete Masonry Units shall conform with strength requirements of ASTM C90 - C. Wood Minimum
Specific Gravity = 0.55
12. shims are optional. Max. shim stack is 1/4".
13. When using a 1/4"0 Tapcon or #12 wood screw through the window frame, pre -drill the thru hole at specified installation screw locations.
14. When used in areas requiring Impact protection, this product REQUIRES the use of approved Impact resistant shutters or other external protection.
1 5, Flashing should be applied using the ASTM E 2112 method appropriate for the opening into which the window is being installed.
16. Glazing shall comply with ASTM E 1300.
17, Products shall be constructed as specified in test reports ATI-C2272.01-109-47,10 and ATI-C2274,02-501-47-,0
DISCLOSURE STATEMENT
This document is the browny of Simonton Wi.dVAA which retains dIJ
lin,pOet.n, and other right, to its fribact: ncut— This document is
provided to the recipient on the expressed condition that it Is not to be
J1.1-ed, reproduced In whole ., AtH, no, used in bj.—I.n with in,
design, 'manufacture or repair of goods for anyone of-, than Simonton
mm,dt Its consent. This restriction does not limit the
odpl—'snight". utIf s information dto't.lo'd In this d—e", wW&
., VEfly .1o.1hod from sr.th, ,.
SIMONTON*
�B`"""IN0095
Dimensional Tolerances
000 * � 11 O w
DRAWNBY: I DAU
Unless Otherwise Specified
11
I Counter, Avon.,
Recast, WV 2,5415
T.U.D. 12
CHECKED BY; DAH
Decimals ArOld,
SCALE:
APPRVD BY: DATI
FIT I of I
x '01 0- 30 min.SERIES:
.Xxx - .005
43-35 / 43-40 PICTURE (FIXED) WINDOW
3/22/23, 12:43 PM Florida Building Code Online
lum
3CIS Home Log In User Registration Hot Topics Submit Surcharge Stats & Facts Publications Contact Us BCIS Site Map Links Search
Product Approval
USER: Public User
b ,
ELQLu.Cj Approval Menu > Product Or Application Sear > Apgliwtion Li. t > Application Detail
mc-'ago
ME
FL #
7-
FL14094-R7
Application Type
Revision
Code Version
2020
Application Status
Approved
Comments
Archived
Product Manufacturer Wincore Window Company, LLC
Address/Phone/Email 250 Staunton Avenue
Parkersburg, WV 26104
(304) 485-7460 Ext 228
dgeorge@wincorewindows.com
Authorized Signature Danny George
dgeorge@wincorewindows.com
Technical Representative
Address/Phone/Email
Quality Assurance Representative
Address/Phone/Email
Category Exterior Doors Swinging
Subcategory Swinging Exterior Door Assemblies
I
Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida
Professional Engineer
Evaluation Report - Hardcopy Received
Florida Engineer or Architect Name who developed Lyndon F. Schmidt, P.E.
the Evaluation Report
Florida License PE-43409
Quality Assurance Entity National Accreditation and Management Institute
Quality Assurance Contract Expiration Date 12/31/2023
Validated By Ryan 3. King, P.E.
Validation Checklist - Hardcopy Received
Certificate of Independence Ej14094—E7--Q(h) Certfficatg-gf Indepgad—e—nc!z.p�df
Referenced Standard and Year (of Standard) 5tandar-d Year
ASTM E330 2002
Equivalence of Product Standards
Certified By
Sections from the Code
Product Approval Method Method 1 Option D
https://floridabuilding.org/pr/pr_app_dti,aspx?param=wGEVXQvvtDqtGLR%2byCBylJnZwKRjBxEq6X3nMM2FBsga6L7YE6oToLQ%3d%3d 1/3
RMAINMEMA
Florida Building Code Online
Date Submitted
07/08/2020
Date Validated
07/08/2020
Date Pending FBC Approval
07/13/2020
Date Approved
10/13/2020
�qmrijary,Rf. Products
FL # Model, Number or Name Description
14094.1 a. Wincore Fiberglass Entry Door 6'8 "Non -Impact" Glazed Fiberglass Single Door with or
I I without Sidelite(s) - (Inswing/Outswing X, OX or XO; OXO -
I I Configurations)
Limits of Use Installation Instructions
Approved for use in HVHZ: No i fL14g24_R7IUhlLnaLI4224.1.p_df
Approved for use outside HVHZ: Yes Verified By: Lyndon F. Schmidt, P.E. 43409
Impact Resistant; No Created by Independent Third Party: Yes
Design Pressure: N/A Evaluation Reports
Other., See INST 14094.1 for Design Pressure Ratings, any 140_94 1 pgff
additional use limitations, installation instructions and product Created by Independent Third Party: Yes
particulars.
14094.2 b. Wincore Fiberglass Entry Door
j 618 "Non -Impact" Glazed Fiberglass Double Door -
Instin2/Outswing XX Configuration)
Limits of Use
Installation Instructions
Approved for use in HVHZ: No
EL14 ln_,t 14094.2 pfff
Approved for use outside HVHZ: Yes
Verified By: Lyndon F. Schmidt, P.E. 43409
Impact Resistant: No
Created by Independent Third Party: Yes
Design Pressure: N/A
Evaluation Reports
Other* See INST 14094.2 for Design Pressure Ratings, any
i FL14094 R7 AE (b) _Ev Al 14_Q94.2.p A
additional use limitations, installation instructions and product Created by Independent Third Party: Yes
particulars.
14094.3 c. Wincore Fiberglass Entry Door 68 "Non -Impact" Opaque Fiberglass Single Door with or
without Sidelite(s) - (Inswing/Outswing X, OX or XO; OXO -
Configurations)
Limits of Use Installation Instructions
Approved for use in HVHZ: No 1
t 140 4 �pdf
Approved for use outside HVHZ: Yes Verified By: Lyndon F. Schmidt, RE. 43409
Impact Resistant. No 1 Created by Independent Third Party: Yes
Design Pressure: N/A i Evaluation Reports
Other- See INST 14094.3 for Design Pressure Ratings, any 1
fL14924-R7—AUW_Eval 14024.3.pdf
additional use limitations, installation instructions and product Created by Independent Third Party: Yes
particulars, i
14094.4 d. Wincore Fiberglass Entry Door i 6'8 "Non -Impact" Opaque Fiberglass Double Door -
1 1 (Inswing/Outswing XX Configuration)
..... . .. -------
Limits of Use Installation Instructions
Approved for use in HVHZ: No j LL14094 R7 11 (12) Inst 14094.4.pfff
Approved for use outside HVHZ: Yes Verified By: Lyndon F. Schmidt, P.E. 43409
Impact Resistant: No Created by Independent Third Party: Yes
Design Pressure. N/A Evaluation Reports
Other: See INST 14094.4 for Design Pressure Ratings, any fFLL14024_27_AE_f(?)_kval 14094.4.p�df
additional use limitations, installation instructions and product Created by Independent Third Party: Yes
particulars.
14094.5 e. Wincore Fiberglass Entry Door 8'0 "Non -Impact" Glazed Fiberglass Single Door with or
without Sidelite(s) - (Inswing/Outswing X, OX or XO; OXO -
Configurations)
Limits of Use
I Installation Instructions
Approved for use in HVHZ: No
EL14094 R7 II (h)jn5t �14094, .pdf
Approved for use outside HVHZ: Yes
Verified By: Lyndon F. Schmidt, P.E. 43409
Impact Resistant, No
Created by Independent Third Party: Yes
Design Pressure: N/A
Evaluation Reports
Other: See INST 14094.5 for Design Pressure Ratings, any I At 14094,-5_,pdf
additional use limitations, installation instructions and product Created by Independent Third Party: Yes
particulars. I
14094.6 1 f. Wincore Fiberglass Entry Door
Limits of Use
Approvo
Impact Resistant. No
Design Pressure: N/A
8'0 "Non -Impact" Glazed Fiberglass Double Door -
(Inswing/Outswing XX Configuration)
Installation Instructions
EL14D24-_R7--U-jh)-Lnat 14094.6,pdf
Verified By: Lyndon F. Schmidt, RE, 43409
Created by Independent Third Party: Yes
Evaluation Reports
https:llfloridabuilding,orglprlpr�_app_dti.aspx?param=wGEVXQ\,vtDqtGLR%2byCBylJnZwKRjBxEq6X3nMM2FBsga6L7YE6oToLQ%3d%3d 2/3
WINCORE FIBERGLASS ENTRY DOOR
INSWING / OUTSWING
NON-llmmcr
1. This product has been evaluated and is in compliance with the 7th
Edition (2020) Florida Building Code (FBC:) structural requirements
excluding the "High Velocity Hurricane Zone" (HVHZ),
I Product anchors shall be as listed and spaced as shown on details.
5
a Anchor embedment to base material shall be beyond wall
I i
dressing or stucco.
L I When used in areas requiring wind borne debits protection, this
o
product is required to be protected with an impact resistant
covering that complies with FBC Sections 1609. 1.2 & R301.2.1 2
z
I
4. For 2x stud framing construction, anchoring of these units shall be
the same as that shown for 2x buck masonry construction.
5. Site conditions that deviate from the details of this drawing require
further engineering analysis by a licensed engineer or registered
architect.
TABLE OF CONT-ENTS
#
DESCRIP17ON
_MEET
I
Typical elevations, design pressures & general notes
2
Door panel details
3
Siderite panel & gla2ing details
4
Elevations
5
Vertical cross sections
6
Horizontal cross section-s
7
Buck anchoring
8
Frame anchoring & hardware details
1
37SYMAX. OVERALL
FRAME WIDTH
try z
::I z
�E
X 0
2 ,
<
74.75'MAX, OVERALL
FRAME WIDTH
112,11" MAX, OVERALL
FRAME WIDTH
----------------
MaE251
N
tq
O
,z
N
8
DATE: 6/15/15
SCAU1. MT.&
OWG BY: JK
CHK SY, I FS
FL- 14094,3
IT I OF 9
A
071 2.8" —
OX EXTERIOR OX
INTERIOR
CAP (Pvc)7
LATCH STILE fLVLj HINGE STILE (LVQ CAP (PVC)
HORIZONTAL CROSS SEC77ON
is
11,15'DCIOR
WIDTH
16
0
0
0
ry
i�
O
SEE DOOR LOCK
HARDWARE TABLE
2
2
2
z
�DWRI.PAMEL
t 40 Plastpro
Fiberglass
tC
KNOB: SIGNATURE SERIES
DEA� ;*MSIGNA�TURESEAJBS
TOP RAIL
(COMP')
INTERIOR
EXTERIOR
FOAM CORE
(POLYURETHANE
N PCF MIN,)
FIBERGLASS SKIN
(0,075- MIN. THK.)
BOTTOM RAIL
(COMP.)
VER17CAL CROSS SECTION
z
"S
z
0 n
C14 z
E m
& .0
I <1
0-
N I a -"I 1 h
LE; MT.S,
ED
ED
BY: JK
BY: LFS
AtC
FL— 14094-3
ET OF
m
ammm
EXTERIOR 18T" 4'
A
STILE (LVQ G1 INTERIOR STILE (LVQ CAP (PVC)
1 HORIZONTAL CROSS SECTION
3
35.75" MAX. PANEL
WIDTH
*so SID_ PANEL
'I.sP'.
Fiberglass
1,
21"MAX" -moo
6
C;
#8 x 2-1/2" PPH SMS
(TYP-)
#8X 1-1/7'
3.25'
gyp)
PPH SMS
ODL LITE FRAME
INTERIOR
EXTERIOR
?13e
*01DIL 111E IRAME
A , pa".
3-H2P Polypropylene
GLASS BITE 3/9'
112" OVERALL GLASS THK.
1/8"TEMPERED GLASS
AIR SPACE
1/87EMPERED GLASS
ALUMINUM SPACER
READI-SEAL GLAZING
COMPOUND
4®fi
% A--
z �-i
>
0 -z
E
-z
INTERIOR EXTERIOR
FOAM CORE
(POLYURETHANE- d.
L9 PCF MIN.)
FIBERGLASS SKIN
(0.075" MIN. THK,)
BOTTOM RAIL --
(COMP.)
VERTICAL CROSS SE Odd
E: 6/15/15
N.T.S.
c By: LFS
iWING NO:
FL— 14094.3
-fT —3 OF
m
ELEVATION
X0 / ox
El
;UT
—4)
ILJ
0
V-
4) 4) 1) ( U�6
ELEVATION
oxo
d
z
Z
INTERIOR Ilfi
EXTERIOR
VERTICAL CROSS SEC
2n-,n Clow 10,it—ng Simi X B.Cj C.n,Lofi ctiorI I
RMPAVEMMUMM
INTERIOR EXTERIOR
�2 VERTICAL CROSS SECTION
Inswing how X Buashown (Outswing Similar)
Construction
SEE NOTE
INTERIOR EXTERIOR
r3� VERTICAL CROSS SECTION
ri-In shown g similar) X flock _TC cation
n
NOTE:
1. Spacing for sidelite screws (Itern MI:
6'from each end (2 total).
z
INTERIOR EXTERIOR
(i� 50
SEE NOTE I
H
z H D D
Z a:
/�4 " VERTICAL CROSS SECTION 5 1 VERTICAL CROSS SECTION VERTICAL CROSS SECTION K7 VERTICAL CROSS SECTION
Inswing sill t 5j Oulswing A Inswing sill Inswing sill
INTERIOR
INTERIOR - EXTERIOR
SCALE: N T.S
DWO. BY: JK
GHK. BY: LFS
DRAWING NO,
FL- 14094.3
SHEET 5 OF 9
C 0,151,
B F C'SINK
o
D �WERJ,
10 INTERIC
L 9
11
EMB. (TYP.)
HORIZONTAL CROSS SECTION
Inswingshown (OM—smng similar)
2X Buck Construction
NOTE:
I Spacing for sidelite screws (item M): 6,5', 38.5"
and 69"from head to A f3 total).
15"
E A T —� o I— 0 , C'SINK
�,FXMIWAW
4 "� HORIZONTAL CROSS SECTION
"-1
Inswing
shown (Outswingsimilar)
) Buck Construction
0.15' - --
C'SINK
1-1/4"MIN.
EMB, (TYP,)
F
SEE NOTE I
( M
EXTER )
Log \
6-'HORIZONTAL CROSS SECTION
�,6 InEvAFg shown —(Outswng similar)
1-IMMIN.
EMB. (TYP.)
.........s®e..
z
>
.
P1 z
.,2
1i till 0 .
on
0 z 6 'a
0 o W.
C-4 z W.
M,
M
6
z
ik
0 0
0 Q�
EE NOTE I
w Co Q co
-5
Uj
ED
lz-
z
0
z
DATE: 611511
SCALE, MT.S.
DWG. SYJ�K
CW BY: LFS
DP WING
FL— 14094.3
SHEET 6 or 9
61 3(TYP.) 6' (TYp.)
fTyp.) 4- (TYP.)
DETAIL I
F 2X BUCK F 2X BUCK
J IX BUCK J IXBUCK
HEAD & JAMBS HEAD & JAMBS
PP.) (TYP.)
x x
SILL (TYP.) a SILL (TYP.)
FRAME -- (DETAIL2
The head is attached to the jornb w/
_ ". I
4 1
The threshold is attached to the jamb
w/ (3) 7/1 e x 2' steal crown staples &
(1) #8 x 1-5/8wood screw fTYP.j
FRAME ANCHORING
zo
0 ;--
0
�o
OWE
la
LL
G I X BUCK
2X BUCK• z
L 2X REINF,
.2 6-
6
SEE HINGE 10 fill, f4 > ; z
DETAIL 1 6 -
0 n
z
HINGE DETAIL I E
6
G IXBUCK 6
2X BUCK E z
L 2X REINF.
A
_ 10
O
SEE HINGE
DETAIL 2
0 HINGE DETAIL 2 W E2 M 00
Q� z
HINGE JAMB
#8 x 31 COUR'E,,,-��
THREAD
DRYWALLSCREW
DETAIL I
Integral mullion attachment
#8 X 3" COURSE
THREAD
DRYWALL SCREW:,��'*
DETAIL 2
Integral mullion attachment
IX BUCK P
13
2X BUCK
K
2X REINK
IXBUCK
Ar,
2X BUCK
2X REINF.
12
2X BUCK
L 2X REINF.
G I X BUCK
LATCH AND DEADBOLTSTRIKE DETAILS
0ur
WOO
On
<
4d
MMIF
O z
N.T.S. 6
0y; JK
C BY. LFS
ANG Na.
FL- 14094.3
:E7 8 OF 9
f Fe7!__7 7-7 7 7 n
4.56" -
@YI�IIWING THRESHOLD
d.r. (Z_,esl
SIDELITE
ADAPTER
Lv
4.56"
C1
2.44-
CD
@_0 ING THRESHOLD
"W
SIDELITE
ADAPTER
CD
4,56'
*,0 WING 11111101DWL11DILITEADAPTER
z
0 M .0
6
#it fill
I
0
- - 0
C,4
CS
4 IE 6- Ei
ii
u, C5 SO
I
6
-Z
ZE
10
I
ki
CONCRETE ANCHOR NOTES:
1. Concrete anchor locations at thecomers may be adjusted to maintain the min.
edge distance to rnor""Joints,
2, Concrete anchor locations noted as "MAX. ON CENTER" must be adjusted to
maintain the min, edge distance to mortarjoirris, additional concrete anchors
=y be required to ensure the "MAX, ON CENTER" dimension are not exceeded.
3. Concrete anchor table:Arc
ANCHOR ANCHOR MIN_ MIN, CLEARANCE MIN, CLEARANCE
5
TYPE SIZE EMBEDMENT TO MASONRY TO ADJACENT
EDGE ANCHOR
ITW BUILDEX 3116- 1_1X 31 1-1/2-
SCALE: N.T.S.
TAPCON' 1/4" 1-1/4' — _2' 4"
DWG. ev; JK
ELCO 1.
ULTRACOPr 1/' 1-1/4- 4'
CHX. By.. LFS
DRAWING NO-:
WOOD SCREW INSTALLA77ON NOTES:
FL-14094.3
1. Maintain a minimum 5/8" edge distance, I"end distance, & Y' o.c. spacing of
wood screws to prevent the splitting of wood.
SHEET 9 OF 9
z
a