BNR-006207-2023
Phone: (813) 780-0020
Fax: (813) 780-0021
Issue Date: 05/08/2023
Permit T e: Building New Residential)
04 26 21 0160 00300 0270 36431 Flats Street
a
W, 3
g,
0
Name: LENNAR HOMES LLC Permit Type: Building New (Residential) Contractor: LENNAR HOMES LLC
Class of Work: SFR Construct
Address: 4301 W Boy Scout Blvd 600 Building Valuation: $365,520.00
TAMPA, FL 33607 Electrical Valuation: $54,828.00
Phone: Mechanical Valuation: $25,586.40 t
Plumbing Valuation: $36,552.00
Total Valuation: $482,486.40
Total Fees: $21,050.46
Amount Paid: $0.00 1,7_52-3
I Date Paid: 5/8/2023 1:55:41 PM
CONSTRUCT SINGLE FAMILY 2584 SO FT
Driveway Fee $45.00 Building Plan Review Fee $180.00
Plumbing Permit Fee $222.76 Water Connection Residential Fee 1,140.00
Electrical Plan Review Fee $OAO Sewer Connection Residential Fee 2,400.00
3t4 Water Meter Fee {Cale) $794.92 School Impact Fee -Single Family 8,328.00
Plumbing Plan Review Fee $0.00 Electrical Permit Fee $314.14
Building Permit Fee $1,867.60 Public Safety Impact Fee -Police $254.00
Mechanical Permit Fee $167.93 Public Safety Impact Fee -Admin $26.35
Mechanical Plan Review Fee $0.00 Irrigation 3/4 Meter (Calc) $794.92
Address Fee $30.00 Transportation Impact Fee - City $36.32
Park Impact Fee - Single Family/Townhome $769.56 SIF 1 percent Fee $83.28
LTransportation Impact Fee $3,595.68
Mr
ism
ITC170fUl I0bLIIUL[1IFI5 a��Filcame To inis prope Pya,
may be found in the public records of this county, and there may be additional permit required from other governmental
entities such as water management, state agencies or federal agencies.
"TTarning to owner: Your failure to record a notice of commencement may result in your paying twice
improvements to your property. If you intend to obtain financing, consult with your lender or an afforn
before recording your notice of commencement."
Complete Plans, Specifications add fee Must Accompany Application. All work shall be performed in
accordance with City Codes and Ordinances. NO OCCUPANCY BEFORE C.O.
NO OCCUPANCY BEFORE C.O. I
IA
CONTRACTOR SIGNATURE
04 - M11-
OFFICEC)
THOUT APPROVED INSPECTION
CALL FOR INSPECTION - 8 HOUR NOTICE REQUIREl'i
PROTECT C1RD FROM WEATHER I
813 /80-0020 City of Zephyrhills Permit Application Fax-813-780-0021
F Building Department
— ---------
Date Received Phone Contact for Permitting 9(i8 770 — 7763
-Fr T7... r-V t....t....t--.i_-t.
Owner's Name CAL HEARTHSTONE LOT OPTION POOL 03 L P Owner Phone Number r 813S745700
Owner's Address 23975 Park Sorrento, Ste. 220, Calabasas, GA 91302 Owner Phone Number
Fee Simple Titleholder Name NIA Owner Phone Number
Fee Simple Titleholder Address
I N/A
JOB ADDRESS
36431 Flats Street
LOT
# 0327
SUBDIVISION
Abbott Squares
PARCEL ID# 1
04-26-21-0160-00300-0270
IOBTAINED FROM PROPERTY TAX NOTICE)
WORK PROPOSED
P
NEW CONSTR e ADD/ALT SIGN 0
INSTALL REPAIR
DEMOLISH
PROPOSED USE 0 STIR COMM OTHER
TYPE OF CONSTRUCTION 10 BLOCK FRAME STEEL 0
DESCRIPTION OF WORK
I Single Family Residence I Pool / Screen Enclosure / Fence
I UIR SF 3046 253q 28
BUILDING SIZE SQ FOOTAGE HEIGHT
/ BUILDING
$ 365520
VALUATION OF TOTAL CONSTRUCTION
�—
1.1 (ELECTRICAL
$ 54828
PROGRESS ENERGY
W.R.E.C.
AMP SERVICE
�L��
I.f (PLUMBING
$ 36552
qy (MECHANICAL
Y ♦ (GAS
$ 25586.4
VALUATION OF MECHANICAL INSTALLATION
ROOFING SPECIALTY = OTHER
FINISHED FLOOR ELEVATIONS
FLOOD ZONE AREA [IYES Do
BUILDER COMPANY Lennar homes, LLC
SIGNATURE REGISTERED Y / N FEE CURREN I Y / N
Address _430 W Boy Scout Blvd Suite 600 Tampa, FL 33607 License # CGC1518166
ELECTRICIAN 7 COMPANY Edmonson Electric, Inc.
SIGNATURE REGISTERED Ly I N FEE CURREN Y I N
Address License# EC13005408
Ba anet Pl
PLUMBER —� COMPANY Y umbin g, Heating & AC, Inc
SIGNATURE REGISTERED Y / N FEE CURREN
Address License # CFC042998��
MECHANICALCOMPANY Bayonet Plumbing, Heating & AC, Inc
SIGNATURE 4 REGISTERED Y/ N FEE CURREN I Y/ N
Address I License # CAC058062
OTHER COMPANY C Sterling Quality Roofing, Inc
SIGNATURE REGISTERED Y ( N FEE CURREN Y / N
Address License # CCC05 '991
RESIDENTIAL Attach (2) Plot Plans; (2) sets of Building Plans; (1) set of Energy Forms; R-O-W Permit for new construction,
Minimum ten (10) working days after submittal date. Required onsite, Construction Plans, Stormwater Plans w/ Silt Fence installed,
Sanitary Facilities & 1 dumpster; Site Work Permit for subdivisions/large projects
COMMERCIAL Attach (2) complete sets of Building Plans plus a Life Safety Page, (1) set of Energy Forms. R-O-W Permit for new construction.
Minimum ten (10) working days after submittal date. Required onsite, Construction Plans, Stormwater Plans w/ Silt Fence installed,
Sanitary Facilities & 1 dumpster. Site Work Permit for all new projects. All commercial requirements must meet compliance
SIGN PERMIT Attach (2) sets of Engineered Plans.
****PROPERTY SURVEY required for all NEW construction.
Directions:
Fill out application completely.
Owner & Contractor sign back of application, notarized
If over $2500, a Notice of Commencement is required. (A/C upgrades over $7500)
Agent (for the contractor) or Power of Attorney (for the owner) would be someone with notarized letter from owner authorizing same
OVER THE COUNTER PERMITTING (copy of contract required)
Reroofs if shingles Sewers Service Upgrades A/C Fences (PioUSurvey/Footage)
Driveways -Not over Counter if on public roadways..needs ROW
NOTICE OF DEED RESTRICTIONS: The undersigned understands that this permit may be subject to "deed" restrictions"
which may be more restrictive than County regulations. The undersigned assumes responsibility for compliance with any
applicable deed restrictions.
UNLICENSED CONTRACTORS AND CONTRACTOR RESPONSIBILITIES: If the owner has hired a contractor or
contractors to undertake work, they may be required to be licensed in accordance with state and local regulations. If the
contractor is not licensed as required by law, both the owner and contractor may be cited for a misdemeanor violation
under state law. If the owner or intended contractor are uncertain as to what licensing requirements may apply for the
intended work, they are advised to contact the Pasco County Building Inspection Division —Licensing Section at 727-847-
8009. Furthermore, if the owner has hired a contractor or contractors, he is advised to have the contractor(s) sign
portions of the "contractor Block" of this application for which they will be responsible. If you, as the owner sign as the
contractor, that may be an indication that he is not properly licensed and is not entitled to permitting privileges in Pasco
County.
TRANSPORTATION IMPACT/UTILITIES IMPACT AND RESOURCE RECOVERY FEES: The undersigned understands
that Transportation Impact Fees and Recourse Recovery Fees may apply to the construction of new buildings, change of
use in existing buildings, or expansion of existing buildings, as specified in Pasco County Ordinance number 89-07 and
90-07, as amended. The undersigned also understands, that such fees, as may be due, will be identified at the time of
permitting. It is further understood that Transportation Impact Fees and Resource Recovery Fees must be paid prior to
receiving a "certificate of occupancy" or final power release. If the project does not involve a certificate of occupancy or
final power release, the fees must be paid prior to permit issuance. Furthermore, if Pasco County Water/Sewer Impact
fees are due, they must be paid prior to permit issuance in accordance with applicable Pasco County ordinances.
CONSTRUCTION LIEN LAW (Chapter 713, Florida Statutes, as amended): If valuation of work is $2,500.00 or more, I
certify that 1, the applicant, have been provided with a copy of the "Florida Construction Lien Law —Homeowner's
Protection Guide" prepared by the Florida Department of Agriculture and Consumer Affairs. If the applicant is someone
other than the "owner', I certify that I have obtained a copy of the above described document and promise in good faith to
deliver it to the "owner" prior to commencement.
CONTRACTOR'S/OWNER'S AFFIDAVIT: I certify that all the information in this application is accurate and that all work
will be done in compliance with all applicable laws regulating construction, zoning and land development. Application is
hereby made to obtain a permit to do work and installation as indicated. I certify that no work or installation has
commenced prior to issuance of a permit and that all work will be performed to meet standards of all laws regulating
construction, County and City codes, zoning regulations, and land development regulations in the jurisdiction. I also
certify that I understand that the regulations of other government agencies may apply to the intended work, and that it is
my responsibility to identify what actions I must take to be in compliance. Such agencies include but are not limited to:
Department of Environmental Protection -Cypress Bayheads, Wetland Areas and Environmentally Sensitive
Lands, Water/Wastewater Treatment.
Southwest Florida Water Management District -Wells, Cypress Bayheads, Welland Areas, Altering
Watercourses.
Army Corps of Engineers -Seawalls, Docks, Navigable Waterways.
Department of Health & Rehabilitative Services/Environmental Health Unit -Wells, Wastewater Treatment,
Septic Tanks.
US Environmental Protection Agency -Asbestos abatement.
Federal Aviation Authority -Runways.
I understand that the following restrictions apply to the use of fill:
Use of fill is not allowed in Flood Zone W" unless expressly permitted.
If the fill material is to be used in Flood Zone "A", it is understood that a drainage plan addressing a
"compensating volume" will be submitted at time of permitting which is prepared by a professional engineer
licensed by the State of Florida.
If the fill material is to be used in Flood Zone "A" in connection with a permitted building using stem wall
construction, I certify that fill will be used only to fill the area within the stem wall.
If fill material is to be used in any area, I certify that use of such fill will not adversely affect adjacent
properties. If use of fill is found to adversely affect adjacent properties, the owner may be cited for violating
the conditions of the building permit issued under the attached permit application, for lots less than one (1)
acre which are elevated by fill, an engineered drainage plan is required.
If I am the AGENT FOR THE OWNER, I promise in good faith to inform the owner of the permitting conditions set forth in
this affidavit prior to commencing construction. I understand that a separate permit may be required for electrical work,
plumbing, signs, wells, pools, air conditioning, gas, or other installations not specifically included in the application. A
permit issued shall be construed to be a license to proceed with the work and not as authority to violate, cancel, alter, or
set aside any provisions of the technical codes, nor shall issuance of a permit prevent the Building Official from thereafter
requiring a correction of errors in plans, construction or violations of any codes. Every permit issued shall become invalid
unless the work authorized by such permit is commenced within six months of permit issuance, or if work authorized by
the permit is suspended or abandoned for a period of six (6) months after the time the work is commenced. An extension
may be requested, in writing, from the Building Official for a period not to exceed ninety (90) days and will demonstrate
justifiable cause for the extension. If work ceases for ninety (90) consecutive days, the job is considered abandoned.
JURAT (F.S. 117,03)
OWNER OR AGENT
Subscribed and sworn fo (or affirmed) before me this
1 by Christopher Smith
Who islare personally known to me or
—as identification.
Notary Public
Commission G 2960S7
Stephanie Farmer
Name if Notary typed, printed or stamped
E j
xomsiu"6,2024
fis i
le alrai, 010111RININ
Subscribed and sworn to (or affirmed) before me this
312M023 _by Christopher Smith
Who islare personally known to me or has/have produced
as identification.
—Notary Public
Commission No. 6 7
Stephanie Farmer
Name of Notary typed, printedor stamped
WS$AM, ROL
Permit No. &Z7
A
,0Date Permitted 56- Z3
Builder Name/Owner Name---24j- 1�c ilt4— —14vLa-- Control
County Parcel No. O�2 b Z, / LL6, LSO �2 /-VSubDiv:2�
Address/Location 36 14 1,
Classification/Type of Use
Rate: —
Sq. Ft Unit: z4z2—
.......
Impact Fee Amount Zone No. TAZ:—
SCHOOL IMPACT FEE
Account (056) Single -Family Detached House Amount $
(057) Mobile Home
(058) Other Residential
(123) Collection Fee
Exempt =Yes = No How Determined_
PARKS AND RECREATION FEE
Land Account Land Credit Land Total
Recreation Account _ Recreation Credit Recreation Total
Zone AmountT +�l Ant $ f56
Exempt =Yes = No
LIBRARY FEE
Land Account Land Credit Land Total
Facility Account _ Facility Credit _ Facility Total
Exempt 1:1 Yes = No How Determined Total Amount
RESOURCE FEE ERU
EM
Checked By
6�1
NO CERTIFICATE OF OCCUPANY WILL BE ISSUED OR FINAL INSPECTION
PERFORMED UNTIL THE TOTAL AMOUNTS LISTED HAVE
10.44IV4-zo�tl% - �� 1 '41-•E OF P ASrn-rfV lulo"
ACKNOWLEDGEMENT BELOW DOES NOT IMPLY ACCEPTANCE OF CONCURRENCE, BUT SIMPLY REECEIPT OF A COPY OF THIS
FORM, PLACING THE BUILDING OWNER ON NOTICE OF THIS ASSESSMENT AND THE CONDITIONS OF PAYMENT FOR SAME.
RECEIVED BY
RECEIPT NO — DATE BY
-88.1
ILT FENCE
EM
191
11-
94.3
0
77-�
78-::���
79-
go---
81-
82-
83-
84-
85-
-----���86
93
DESCRIPTION: LOT 27, BLOCK 3, ABBOTT SQUARE PHASE 2, SITE PLAN
ACCORDING TO THE PLAT THEREOF, RECORDED IN PLAT BOOT( 90,
PAGES 28-33, OF THE PUBLIC RECORDS OF PASCO COUNTY, (NOT A SURVEY)
FLORIDA. This SITE PLAN Prepared for and Certified To:
Lcnnar Homes
LOT
= 6050
SQ_ Fl
LIVING AREA
= 1093
SO- FT.
ENTRY
= 35
soFT
GARAGE
= 427
SQ. FT.
COVERED LANAI
= N/A
SO FT.
PATIO
= 2`}
SO. FT.
POOL AREA
=_N�._SQ.
FT.
CONC DRIVE
= 408
SO, FF.
A/C & CONC PAD
= 14
SQ. FT.
SIDEWALK
= 31
SQ. FT
SIDEYARD SWALE
=NLA
SQ. FT.
CONSERVATION AREA
NA
_SO, FT,
LOT OCCUPIED
= 34
@/
AREA TO IRRIGATE
NOTES
LOT GRADING TYPE = A
PROPOSED PAD ELEVATION = 95,50'
FRONT SET BACK = 20'
SIDE SET BACK = T5'
SIDE SET BACK (CORNER LOT) =10"
REAR SETBACK = 15'
PROPOSED:
MINIMUM FLOOR ELEVATIONS:
TRACT'B-1"
(CDD) ACCESS/DRAINAGE/LANDSCAPE/
WALL MAINTENANCE AND FENCE AREA,
OPEN SPACE
S 89-48'04" W (P) 55dU (PI
\B-Zq`.
LOT 27
BLOCKS
__________
�9S
oo/
2.7'X2.7 4.0'X6.0 !
C/S-A/C C/S-A/C z
o + (2) o
N 7.540.0' 7.5' vi
LOT PROPOSED LOT 26
BLOCKK 3
o 2 STORY RESIDENCE o BLOCK 3
o PLAN 2575 0 0
w
� � ccELEV "Ai" �D q
b GARAGER i
/9F
5' CONC WA
SEC 4, TWP, 26 S, RNG 21 E.
PASCO COUNTY, FLORIDA
(ABBOTT SQUARE PHASE 2)
Scale-, I" = 20'
7.5' ENTRY 4 -0 1 7.5'
3 ( I
CA
WON
ALK
(� N 89-48'04- E (P)
502.97' (P)
Hg. f PRM
N 89`4804"E(P) 5500 JP). f:
22.0,
BASIS OF BEARING
N 89-48'04- E IP)
FLATSSTREET
TRACT "A"
(CDD) RIGHT-OF-WAY
< = 10.00 PUBLIC UTILITY EASEMENT
'-.. ALL ELEVATIONS REFERENCED
TO NORTH AMERICAN
VERTICAL DATUM OF 1988
1NAVD 88)
LIVING AREA: 96.17 LEGEND:
GARAGE AREA:
_
��--�- PROPOSED DRAINAGE FLOW
PROPOSED ELEVATIONS AND GRADING
ELEVATIONS REFERENCED TO
SHOWN HEREON ARE TAKEN FORM THE
NORTH AMERICAN VERTICAL (00,00) _ PROPOSED GRADE
ENGINEERING PLANS OF j
DATUM OF 1988 E-00.00 = EXISTING GRADE
'ABBOTT SQUARE RESIDENTIAL-, PREPARED
BY'WRA' PROVIDED BY CLIENT
APPARENT FLOOD HAZARD ZONE:'AE' BFE-89.7' COMMUNITY NO. 120235
SURVEY ABBREVATIONS (MAP NUMBER 12101C-0289-Fl EFFECTIVE DATE: 09/26/2014
—,
AI - ARC LENGTH
IDI - DEED
INV- INVERT
PC - POINT OF CURVE
(RI - RECORD
LEGEND
AJC-AIR CONDITIONER
AF-ALUMINUM FENCE
D.E- DRAINAGE EASEMENT
LS-LICENSED SUISTESS
FCC- POINT OF COMPOUND CURVE
RNG-RANGE
VINYL FENCE
-CONC
SEE-@ASE FLOOD ELEVATION
EL OR ELEV- ELEVATION
FOR - EWE OF PAVEMENT
L.E^ LANDSCAPE EASEMEW
LFE- LOWEST FLOOR ELEVATION
PCP- PERMANENT CONTROL POINT
P/E - POOL EQUIPMENT
RRS - RAIL ROAD SPIKE
R,AV-RIGHT OF WAY
BM-BENCUMARK
C-CURVE
C_CCALCULATED
ESMT-EASEMENT
f5- LICENSED SURVEYOR
PG -PAGE
SEC^SECTION
WOOD FENCE
ASPHALT —"
FJC-FENCE CORNER
FCM-FOUND CONCRETE
(M1^MEASURED
MES- MITERED END SECTION
PI -POINT OF INTERSECTION
PK-PARKER "LON
SN&D - SET NAIL AND DISK
U08183
" • CENTERLINE
CLF-CHAIN
MONUMENT
NCF^NO CORNER FOUND
-PROPERTY UNE
SIR - SET 1/2'IRON RODLBM BIBS
CHAIN LINK FENCE
�'j LINK
LINK FENCE
FIT' - FOUND IRON PIPE
O/A -OVERALL
ROB -POINT OF BEGINNING
TBM ^TEMPORARY BENCH MARK
'� 1-BRICK —�
CMP - CORRUGATED METAL PIP
COL
FIR - FOUND IRON ROD
DOW- OVERHEAD WIRE(SI
POC- POINT OF COMMENc LMENT
For - TOP OF BANK
L... .1
-COLUMN
CONC-CCtlJCRETE
FN&D-FOUNDNAIL&DISK
O.R. - OFFICIAL RECORDS
POE - POINT ON LINE
TWP^TOWNSHIP
ALUMINUM FENCE
C/S-CONCRETE ILPR
FOP -FOUND OPEN PIPE
(PI -PLAT
PRC-POINT OF REVERSE CURVE
U.E^UTILITY EASEMENT
�-COVERED
CST- CLEAR SIGHT TRIANGLE
FPP=FOUND PINCITEDPiPE
PB-PtATBOOK
PRM- PERMANENT REFERENCE MONUMENT
VF - VINYL FENCE
JOB #159.520327
SURVEYOR'S NOTES:
1.1 Current title information on the subject property had not been
furnished to initial Point Land Surveying, LLC. at the time of this
SITE PLAN
2.) This sketch was prepared without the benefit of a title search.
No instruments of record reflecting ownership, easements or
rights -of -way were furnished to the undersigned, unless otherwise
shown hereon.
3.) Roads, walks, and other similar items shown hereon were takera
from engineering plans and are subject to survey,
A,) This SITE PLAN does not reflect nor determine ownership.
P
5.) This SITE PLAN is Plat
SURVEYOR'S CERTIFICATE
This certifies thatOh of the hereon described
1i� 1
property v�l dG y�rlWi;t1►�ty supervision and
ets t Fes; o ractice for
s bty�,� ,f�faSdrFtd
r 5 7 pp Hartle
5JF}9 05 , F ndaWA27*, a V e,
LE
t�"o'' Ion <l72/(( r(�,
t Y j j ;Q �J-Qt}IQQI
i SATE OF p��=
1708 Water Oak Drive -
Tarpon Springs, Florida
P
Phone: (727)-831-1990
FloridaPiS712309maitcom
LB# 8183 'tea
Date of Site Plan: 3-16-23
DWG:AS PH2-L27-BL3SITE
File:
Drawn by: pJ6
Checked by:JH
REVISIONS
subject to matters shown on the of
'ABBOTT
9, N ''FLORIDA ^t� .g
-
SQUARE PHASE 2'
Jeff s ee, a� Fate
6.) Dimensions shown hereon are in feet and decimal portions
FLORI yJ'itBDIS, �j�{ (.SQR AND
JJ��
V
thereof.
MAPPER f�CR t ....-�jt$183
7.) Contractor and owner are to verify all setbacks, building
NOT VALID WITHOUT THE ORIGINAL
dimensions, and layout shown hereon prior to any construction,
and immediately advise Initial Point Land Surveying, LLC. of any
SIGNATURE AND SEAL OF A FLORIDA
deviation from information shown hereon. Failure to do so w111 be
at user's sole risk.
LICENSED SURVEYOR AND MAPPER
Initial Point Land Surveying, LLC.
C, J� S�f fe
Plan Model Elevation
RJ-
Garage
Lot Size
Block
Lot
t
Parcel#: �)O 0 �61�
7
Address:
Setbacks: Front-1- Sides---2—,.S—
Elevation: Garage:
Roof Shingle Dime nsion/Arch itectu ral:
\/V\ +/I/b
R T U A L R E V W A S S t S T
v : Notice to Building Official of
Use of Private Provider
Effective January 20, 2003
WMZ�
Parcel Tax ID: 04-26-21-0160-00300-0270
Services to be provided: Plans Review X Inspections
Note: If the notice applies to either private plan review or private inspection services the Building
Official may require, at his or her discretion, the private provider be used for both services pursuant to
Section 553.791(2) Florida Statute.
the fee
owner, affirm I have entered into a contract with the Private Provider indicated below to conduct the services
indicated above.
Private Provider Firm: VIRTUAL REVIEW ASSIST, INC.
Private Provider: DEBPA ANNE KLAHR
Telephone: 813-376-3088 Fax: N/A
Email Address (Optional): deb@virtualreviewassist.com
#
Florida License, Registration or Certificate #. (LIC BU1967/ PX2300/ BN4615)
I have elected to use one or more private providers to provide building code plans review and/or inspection
services on the building that is the subject of the enclosed permit application, as authorized by s. 553.791, Florida
Statutes. I understand that the local building official may not review the plans submitted or perform the required
building inspections to determine compliance with the applicable codes, except to the extent specified in said law.
Instead, plans review and/or required building inspections will be performed by licensed or certified personnel
identified in the application. The law requires minimum insurance requirements for such personnel, but I
understand that I may require more insurance to protect my interests. By executing this form, I acknowledge that I
have made inquiry regarding the competence of the licensed or certified personnel and the level of their insurance
and am satisfied that my interests are adequately protected. I agree to indemnify, defend, and hold harmless the
local government, the local building official, and their building code enforcement personnel from any and all
claims arising from my use of these licensed or certified personnel to perform building code inspection services
with respect to the building that is the subject of the enclosed permit application.
I understand the Building Official retains authority to review plans, make required inspections, and enforce the
applicable codes within his or her charge pursuant to the standards established by s. 553.791, Florida Statutes. If I
make any changes to the listed private providers or the services to be provided by those private providers, I shall,
within I business day after any change, update this notice to reflect such changes. The building plans review and/or
inspection services provided by the private provider is limited to building code compliance and does not include
review for fire code, land use, environmental or other codes.
The following afta.ohments. are, provided as required:
1. Qualification statements ' and/or resumes of the private provider and all duly. authorized representatives.
2..Proof of insurance for professional .and comprehensive liability in.,the.'amount of $1 million per
o oGuri:ence relating to all services -p t1formed as a private provider, including tail coverage fox a minim -am
of 5 years subsequent to the performance of building code inspection services.,
Individual
-(signature}
Print
NamD:
Address�
Telephone
'Pleawase appropriate notary block.
STATE oF FLORIDA
COUNTY bF HILLSBOROUGH
7LM
Bf,folt me, this day of
20— p ersonaUy
appeared -
who executed the fongo-ing iiistaumtit,
and acknowledged before me that s.mno
was ex=ated for the purposes therein
Print CoipomlionName;
Print
N.e: Christopher Smith
th
Authorized Agent
Address: 700 NW 107th Ave
Miami, FL 33'172
Telephone.
No, .913-674-5700
Corporation
B,,foreme,this 22ND day of
. MAY 20-22
personally appeared.
Lennar Homes, LLO a.
Corporation, on
n
behalf Dfth6-state corporation, who
executed the f6iDgoing instrument and
aclanowltdged bt&bie me that same was
executed for the pirtppges therein
Partnership
PrintPartnership Name
By
Print
Name:
Address; - -
Telephone
No.:
Partnership
BMore me, this day
bf 20
pers6nOy appeared
partner/agent on behalf of
a 'partnership, Who executed the
fMkOillg instrument MCI
acknowledged before me that same
was vxeDuted.forffiop'urpqsestlie;rein
expressed._
Personally known. X Dr- Pro dnobd idmlitcation— Type of idtntiflo akion produced
sipatm OfNotar'v PfiotName- ASHLEE CALLAHAN
Notny?ublic Stamp.:
ASHLEE CALLAHAN
commission Expires: WCOMMISSION #HH295980
W EXPIRES: November 30, 2026
F
VIRTUAL REVIEW ASSIST
Private Provider
Private Provider Finn: Virtual Review Assist, Inc.
Private Provider: Debra Anne Klahr, BU 1967
Address: 747 Southwest 211 Avenue
Gainesville, FL 32601
Phone: 813-391-2959
Email: In jajo,virtualre pyiqNvassist.pom
Project: New SFT
���mwmaaal
I hereby certify that to the best of my knowledge and belief the plans submitted were reviewed for and are in
compliance with the Florida Building Code and all local amendments to the Florida Building Code by the
following want, who is duly authorized to perform plans review pursuant to Section 553.791, Florida Statute
and holds the appropriate license or certificate:
Name: Debra Anne Klahr
Plan Sheets CS,1.1,1,2,3.1,3.2, F1,4.1,4.0,5,6,7.1,7.0,8,SN, SNI, S3,S4,S5, S6,SS, ST,Dl,D2,WP1,WP2,WP2.1,
PAI.0,PAI.1, PAl.2,PAl,3,PA1.4, SHI.0,SHI.1,SHI.2,SHI.3,SHI.4,SHI.5
Florida License/Registration/Certification #(s) and description:
FS468 Certified Standard Plans Examiner
License #: PX2300
Signature of Reviewer:
7' '777
SWORN AND SUBSCRIBED be�fqpd"me by Debra Anne Klahr
being personally known to me or having produced as identification
and who being fully sworn and cautioned, state that the
for go s true and correct to theAbest of his/her knowledge or belief.
Ashlee Callahan
U-1 Frmt Name
commission expires:
999 iiiiii A lill
A614LEE CALLAHAN
W OtAtAISSION # HH 295980
C
er 30,2026
WIRE& NoyeMb
OF
911,
[—COMMERCIAL BUILDING SERVICES DIVISION RESIDENTIAL
BUILDING PERMIT DATA SHEET
101611l'um.1 lawAk"IM -
FIRE MARSHAL #01 -
Required Permits
DATE: 4/18/2023
--
EXAMINER: 5ebra Klahr PX230(
B - uading
El lnspecy2!!Onl.
Plumbing
El Inspection Only
Mechanical
0 Inspection Only
Electrical —Amp
E] Inspection !2nl
Roof
I
E] Medical Gas
E] Fire Sprinklers
❑ On Site Piping
❑ Fire Line
E] Irrigation
El Fire Alarm
El Potable Backflow Assembly
El Fire Line Backflow Preventer
❑ Irrigation Backflow Assembly
El Demolition
El Walk-in Cooler
E] Refrigeration
❑ Hood
El Ansul
El Fence/Wall
0 Grease Trap
❑ Other
El Other
F. r ff F, ff 17.2 -)TIM,
jype Construction: I
V-8
Risk Category:
I Occupancy Load
a, Classification:
:Factory
OV,Fa acy y
Residential
Assembly E::�
Hazardous
Storage E==
iness ay Care/Educational
itutional Q Mercantile
ity
Building Use: SINGLE FAMILY RESIDENCE Alteration Level I Level 2 Level 3
New Construction El Interior Finish ❑ Interior Remodel ❑ Exterior Remodel ❑ Addition Ej Revision
Overall Size:
40 X 43
Number of Stories:
2
Total Sq. Ft.:
3046
Living Area: 2584
Covered Area:
462
# of Bedrooms: 4
—
I # of Baths: 2.5
Cost per square foot:
Estimated Value:
Roof�e: X Shin le
F1 Built-up
E] Metal El Other Squares: 20
-L]Tile
Zoning:
Wi
orne Debris.
OlInside
IQutside
Energy Code: 405-2020
Flood Zone: AE
Base Flood Elevation: 89.7- NAVI) 88
Finish Floor Elevation: 96.17- NAV088
Hydrostatic Vents?
M Yes
Vl No
Sq. Ft. Enclosed Space Below BFE:
# of Vents:
Size of Vents.
Total Sq. In. Permanent Openings
g Central A/C
0 Gas A/C
9 Heat Pump
0 Gas Heat
D Window A/C
El Electric Heat
IG I TIN1113-10ff M.
Sanitary Sewer
Storm Sewer Catch Basins
Potable Water
Under round Fire Line
I ,;Pthneks
— - - - - ------
Front Rear Left Right
As per Approved Site Plan
Comments: ZEPHRYHILL5 TO VERIFY FLOOD INFORMATION
GARAGE EFE - 95.72' NAVO 88
ENGINERRING1 ASSOCIATES
April 11, 2023
Building Department
FDS / KA Project #:
Builder / Contractor:
Plan / Model:
Community / Lot / Block:
Address:
Application / Permit #:
To whom it may concern,
258 Southhall Lane, Suite
Florida
090:: info@fdseng.com
• www.fdseng.com
23-02469
Lennar Homes
2575 / Al / RH
Abbott Square 55 / 27 / 03
36431 Flats Street
We have been informed that the submitted plans for the aforementioned project have not met the
code compliance requirements necessary for approval. Please find our responses to the areas of
deficiencies or corrections required to achieve compliance.
Comment: The structure is located in the special, flood hazard area and shall meet the
minimum required BFE and FFE. Please provide a survey and site -specific
,foundation plan that specifies the BFE and FFE.
Response: The flood heights have been added to sheet 6 Foundation Plan. Please refer to
the clouded areas on sheet 6 for this revision.
If you have any questions, please do not hesitate to call.
4/11/2023
v� ;rVA-
s P 75
rt°gm
a �fON��4�
4/11/2023
Carl A. Brown, P.E. Scott A, Lewkowski, RE
FL. # 56126 FL. #78750
i^ IDS Engineering Associates, A TSG Company
"Your Building CodeExperts"