Loading...
HomeMy WebLinkAbout23-6322City of Zephyrhilis 5335 Eighth Street Zephyrhills, FL 33542 ELCMISC-006322-2023 Phone: (813) 780-0020 Fax: (813) 780-0021 Issue Date: 05/24/2023 Permit T e: Electric Service Replacement/Misc g 7 ,�N�777 11 26 210010 17300 0141 38835 4-rh Avenue M-111M mlzl' - — MEN Name: SEAN LAURSEN Permit Type: Electric Service Replacement/M contractor: SUNRUN INSTALLATION Class of Work: Add/Alter Residential SERVICES INC Address: 38835 4-rh Avenue Building Valuation: $0.00 ZEPHYRHILLS, FLORIDA 33542 Electrical Valuation: $19,743.75 Phone: (813) 838-2515 Mechanical Valuation: Plumbing Valuation: tqt Total Valuation: $19,743.75 Total Fees: $138.72 Amount Paid: $138.72 N. C, Date Paid: 5/24/2023 2:18:40PM Electrical Permit Fee $138.72 ve entities such as water management, state agencies or federal agencies. q—Appilcailon. All worK snail De performed in accordance with City Codes and Ordinances. NO OCCUPANCY BEFORE C.O. NO OCCUPANCY BEFORE C.O. PER�A fiTRACTOR SIGNATURE PEf IATcf P,RES IN 6 MONTHS WITHOUT APPROVED INSPECTION CALL FOR INSPECTION - 8 HOUR NOTICE REQUIRED PROTECT CARD FROM WEATHER 913-780-0020 City of Zephyrhills Permit Application FaX-813-780-0021 Building Department 813 648 - 0086 0 a 00 0 0 W WWO ]VAI le .,.,a W11 Fee Simpte'fitletwoAer Mdross I JODD Y OT # SUBDIVISION PARCEL ID# (OSTMNED FRM PROPERTY TAX NO=E) WORK PROPOSED NEW CONSTRF-� ADDIALT SIGN DEMOLISH INSTALL 0 REPAIR PROPOSEDUSE SFR ED COMM OTHER TYPE OF CONSTRUCTION BLOCK E:] FRAME STEEL DESCRIPTION OF WORK Installation of a roof -mounted photovoltaic solar panel system. 'WILDING SIZE SQ FOOTAGE= HEIGHT [-_-]BUILDING VALUATION OF TOTAL CONSTRUCTION EKELECTRICAL AMP SERVICE PROGRESS ENERGY = WR.E.C. =PLUMBING =MECHANICAL VALUATION OF MECHANICAL INSTALLATION =GAS ROOFING 0 SPECIALTY = OTHER FINISHED FLOOR ELEVATIONS FLOOD ZONE AREA =YES NO BUILDER I COMPANY [Sunrun Installation Services, Inc. SIGNATURE I REGISTERED L�]��N� FEE CURREN YIN Address 528Q Tampa W. Blvd, Tampa FL 3 634License 0 ELECTRICIAN COMPANY Sunrun Installation Services, Inc, SIGNATURE REGISTERED YIN FEE ­CVRREN Address 5280 Tampa lvd, Tampa FL 3363 License # PLUMBER COMPANY SIGNATURE REGISTERED L_yl N_J FEE CURREN YIN Address F- License # F MECHANICAL COMPANY = SIGNATURE REGISTERED YIN FEE CURREN YIN Address License #E==== OTHER COMPANY SIGNATURE R...TERIED L_Y_LN _J FEE cuRRr.N YIN Address License # RESIDENTIAL Attach (2) Plot Plans; (2) sets of Building Plans; (1) set of Energy Forms; R-O-W Permit for new construction, Minimum ten (10) working days after submittal date. Required onsite, Construction Plans, Stormwater Plans wl Silt Fence installed, Sanitary Facilities & I dumpster; Site Work Permit for subdivisionsIlarge, projects COMMERCIAL Attach (2) complete sets of Building Plans plus a Life Safety Page; (1) set of Energy Forms. R-O-W Permit for new construction, Minimum ten (10) working days after Submittal date. Required onsite, Construction Plans, Stormwater Plans w/ Silt Fence installed, Sanitary Facilities & I dumpster, Site Work Permit for all new projects, All commercial requirements must meet compliance SIGN PERMIT Attach (2) sets of Engineered Plans. *—PROPERTY SURVEY required for all NEW co ion. Olrectilons: Fill out application completely. Owner & Contractor sign back of application, notarized If over $2500, a Nice of Commencement Is required (A/C Upgrades over $7SOO) Agent (for the contractor) or Power ofAttomey (for the owner) would be sorneonewith notarized letter from owner authorizing same OVER THE COUNTER PERMrMNG (copy of contract required) Reroofs if shingles sewers Service Upgrades AfC Fences (Plot(Survey/Footage) DrWaways-Not over Counter if on public madways..needs ROW 813-780-0020 City of Zeiphyrhills Permit Application Fax-813-78M21 But ding Department I I Pwrlw� ' o than County regulations. The undersignoed assumes responsibility for cmpliance with any appl6ble deed restrictions. MON q RIPPRON! 1OHN&I'MR&I.Mi'l 1. 114 H. R A WON W. WIN VOWWW"' iM-010- AWSIMM FMA not entitled to permilling privileges In Pasco County. It IN 'i i i•010 MIAMI, all applicable laws regulating construction, zoning and land development. Application is hereby made to obtain a pennit to do work and installation as indicated. I certify that no work or installation has commenced prior to issuance of a pentit and that all work will be performed to meet standards of all laws regulating construction, County and City codm zoning regulations, and land development regulations in the jurisdiction. I also certify that I understand that the regulations of other government agencies may apply to the intended work, and that it is my responsibility to !den* what actions I must take to be in compliance. Such agencies include but are not limited to: - Department of Environmental Protection -Cypress Bayheads, Wetland Areas and Environmentally Sensitive Lands, Water/Wastewater Treatment. - Southwest Florida Water Management District -Wells, Cypress Baybeads, Welland Areas, Altering Watercourses. - Army Corps of Engineers -Seawalls, Docks, Navigable Waterways. - Department of Health & Rehabilitative Services/Environmental Health Untt-Wells, Wastewater Treatment, Septic Tanks. - US Environmental Protection Agency -Asbestos abatement, - Federal Aviation Authority -Runways. I understand that the following restrictions apply to the use of fill: - Use of fill is not allowed in Flood Zone 'V" unless expressly permitted. - If the fill material is to be used in Flood Zone "A", it is understood that a drainage plan addressing a compensating volume" will be submitted at time of penniting which is prepared by a professional engineer licensed by the State of Florida. - If the fill material is to be used in Flood Zone "A" in connection With a permitted building using stem wall construction, I certify that fill will be used only to fill the area within the stem wall, - If fill material is to be used in any area, I certify that use of such fill will not adversely affect adjacent properties. If use of fill is found to qdversely affect adjacent properties, the owner may be cited for violating the conditions of the building permit issued under the attached permit application, for lots less than one (1) acre which are elevated by fill, an engineered drainage plan is required, if I am the AGENT FOR THE OWNER, I promise in good faith to inform the owner of the permitting conditions W forth in this affidavit prior to I 2XII U Its I k TJ I #_I':2 1*1 *1 a I ill W il 01VAA Ji 1:4 a 1�111 M111111* I I h 114 0 1 11;� 4 14 WAS 1, W, L411 I I I Z 19 4 Z, 1 *2 LOMN I I f -J] J 9 1 � JU! 0, V" I � LM 001 'Z, NA I 14 OWNER OR AGENT A 1 $5341it 917UM-61F - M I Rime of Notary typed, printed orspad BRMAW t. DESOLNER ACoattails" # HH 269489 V ,t..Mayll,2026 Name of NRa �typed, painted or simped Y ­" 13RITTANY L DIE A $ ' BOUVER COMMWW # HN 269489 Expim May 1. 2026 Astra v.1.782 May 23, 2023 sunr U n WS CAT 1 Subject : Structural Certification for Proposed Residential Solar Installation. _IVAEW ----- � James Matthew Walsh, State of Florida, Professional Engineer, License No. 84923 Job Number: 802R-835LAUR; Rev A - �: " Client: Sean Laursen o 84921 -V This item has been digitally signed and sealed Address: 38835 4th Ave, Zephyrhills, FL 33542 1 1� X, by James Matthew Walsh, PE on 5/23/2023f Digital Signature. Printed copies of this -ZE using a STATE 4 11 W document are not considered signed and sealec tA, , 4 and the SHA authentication code must be N verified on electronic copies, Attn: To Whom It May Concern /ONAt, A field observation of the existing structure at the address indicated above was performed by a site survey team from Sunrun. Structural evaluation of the loading was based on the site observations and the design criteria listed below. Design Criteria: • 2020 FBC (7th Ed.) AMENDMENTS TO 2018 IRC/IBC/IEBC, 7-16 ASCE & 2018 INDS • Basic (Category 11) Wind Speed V = 138 mph, Exposure B Ground Snow Load = 0 psf Based on this evaluation, I certify that the alteration to the existing structure by the installation of the PV system meets the requirements of the applicable existing and/or new building code provisions referenced above. Additionally, I certify that the PV module assembly including all attachments supporting it have been reviewed to be in accordance with the manufacturer's specifications. 225 Bush St. Suite 1400 San Francisco, CA 94104 ------ it TOP BRAND PV 2021 Warrant 0 CELLS ftal-t & Peu.,­� Yield Security BREAKING THE 20 % EFFICIENCY BARRIER Q.ANTUM DUO Z Technology with zero gap cell layout boosts module efficiency up to 21.4%. THE MOST THOROU13H TESTING PROGRAMME IN THE INDUSTRY Q CELLS is the first solar module manufacturer to pass the most comprehen- sive quality programme in the industry: The new "Quality Controlled PV` of the independent certification institute TOV Rheinland, INNOVATIVE ALL-WEATHER TECHNOLOGY Optimal yields, whatever the weather with excellent low -light and temperature behavior. ENDURING HIGH PERFORMANCE Long-term yield security with Anti LID Technology, Anti PID Technology', Hot -Spot Protect and Traceable Quality Tra,Q`11. EXTREME WEATIHER RATING High-tech aluminum alloy frame, certified for high snow (5400 Pa) and wind loads (4000 Pa). A RELIABLE WVESTMENT Inclusive 25-year product warranty and 25-year linear performance warranty'. APT test conditions according to IEC/TS 52804-1.2015, method, A (-1.50OV, 96h) See data sheet on rear for further information. THE IDEAL SOLUTION FOR: 6F) Rooftop arrays on residential buildings Engineered in Germany OCELLS MECHANICAL SPECIFICATION r 4- or. DUAL A uss-wa-) 57- ELECTRICAL CHARACTERISTICS POWER CLASS 395 400 i. 405 PWP [W] 395 400 405 Ise [A] 11.13 11.16 1119 Voc IV] 45:03 45.06 45.09 h"H IMPP [A] 10.58 10.64 10Y0 VMPP IVI 37.32 3759 37.85 >20A z20:4 a20.6 PMPP IWI 2196A 3MI 303.9 Ise [A] 8.97 8.99 9.02 "k Voc IV) 42A6 42.49 42.52 I.PP [A) 8.33 8,38 8.43 VIAPP [VI 35,59 35.82 36.04 'Measurement tolerances R, ±3%; Voc ±5% at STC: 100OW/m2,25±2'C, AM 1.5 according to ED 60904-3. 2800W/M2, INIMOT, spectrum AM 1.5 Q CELLS PERFORMANCE WARRANTY PERFORMANCE AT LOW IRRADIANCE TEMPERATURE COEFFICIENTS ------ jae as 200 At least 98% of nominal power during first year. Thereafter max. 0.5 % degradation per year. At least 93.5% of nominal power up to 10 years. At least 86% of nominal power up to 25 years. All data within measurement toleranc- es. Full warranties in accordance with the warranty terms of the Q CELLS sales organisation of your respective country. Typical module performance under low irradiance conditions in comparison to STC conditions (25*C, 1000 W/m2) 410 415 1112 11,26 45.13 4516 10.76 10.82 3811 3837 ;�20 ?�21 1 307.6 311.4 904 9.07 42.56 42.59 8.4_81 8.53 36.27 36.49 a [%/K] +0.04 [%/Kj -0.27 y [%/K] _0.34 NIMOT j'Fj 109*5A(43±3,q PROPERTIES FOR SYSTEM DESIGN QUALIFICATIONS AND CERTWICATES PACKAGING INFORMATION UL 61730, CE-compliant,itr Quality Controlled PV - TW Rh,ini nd, O_-O IEC 61215:2016, IEC 6173U01a':s 32 U.S.Patent No, 9,893,215 (solar 76 - 4in 43,3!n 48.0in 1656lbs 24 24 QCPV Certification ongoing. , , C E 1940 Tim 1100 Tim 1220mm 751 kg pallets pallets modules C us UL 61M Note; Installation instructions must be followed, See the installation and operating manual or contact our technical service department for further information on approved installation and use of this product. Hanwha 0 CELLS America Inc. 400 Spectrum Center Drive, Suite 1400, Irvine, CA 92618, USA I TEL +1949 748 59 96 1 EMAIL inquiry@us.q-cells.com I WES www.q-cells.us WSHEE7TINDEX DE CRIPTION SYSTEM SIZE: 10125W DC, 760OW AC ALL WORK SHALL COMPLY WITH 2O20 FBC (7TH ED.) AMENDMENTS TO 2018 COVER SHEET e SERVICE ENTRANCE MODULES: (25) HANWHA Q-CELLS: Q.PEAK DUO BLK IRC/IBC/IESC>, MUNICIPAL CODE, AND ALL MANUFACTL RERS' LISTINGS AND ML-G10+ 405 INSTALLATION INSTRUCTIONS. PV-2.0 SITE PLAN F INVERTERS: (1) SOLAREDGE TECHNOLOGIES: PHOTOVOLTAIC SYSTEM WILL COMPLY WITH NEC 2017. MP MAIN PANEL SE760OH-USSN ELECTRICAL SYSTEM GROUNDING WILL COMPLY WITH NEC 2017. PV-3.0 LAYOUT RACKING: RL UNIVERSAL, SPEEDSEAL TRACK ON COMP, PHOTOVOLTAIC SYSTEM IS UNGROUNDED. NO CONDUCTORS ARE SOLIDLY PV-4.O ELECTRICAL SEE DETAIL SNR-DC-00436 GROUNDED IN THE INVERTER. SYSTEM COMPLIES WITH 690.35. SP SUB -PANEL MODULES CONFORM TO AND ARE LISTED UNDER UL 1703, PV-5.O SIGNAGE INVERTER CONFORMS TO AND IS LISTED UNDER UL 1741. LC PV LOAD CENTER RACKING CONFORMS TO AND IS LISTED UNDER UL 2703. SNAPNRACK RACKING SYSTEMS, IN COMBINATION WITH TYPE 1, OR TYPE It MODULES, ARE CLASS A FIRE RATED, RAPID SHUTDOWN REQUIREMENTS MET WHEN INVERTERS AND ALL SM SUNRUN METER CONDUCTORS ARE WITHIN ARRAY BOUNDARIES PER NEC 690.12(1), CONSTRUCTION FOREMAN TO PLACE CONDUIT RUN PER 690.31(G). ARRAY DC CONDUCTORS ARE SLED FOR DERATED CURRENT. PM DEDICATED PV METER 11.17 AMPS MODULE SHORT CIRCUIT CURRENT. 17.45 AMPS DERATED SHORT CIRCUIT CURRENT [690.8 (A) & 690.8 (B)]. INV INVERTER(S) �� �tlltttilllitrrrrrrr V S\ AC AC DISCONNECTS)No 85111 'y "® WE DC DC DISCONNECT(S) p°S T ATE OF -p CB i IQ COMBINER BOX '`2�r; 0NAi. II ABBREVIATIONSEXPIRES: 2/28/2025 SIGNED: 05/22/2023 INTERIOR EQUIPMENT A AMPERE L __J SHOWN AS DASHED AC ALTERNATING CURRENT AFC ARC FAULT CIRCUIT INTERUPTER _ CHIMNEY sunrun A7_IM AZIMUTH ENGINEER ADDRESS: 225 BUSH ST. SUITE 1406 FDC COMPOSITION SAN FRANCISCO, CA 94104 P: 949-383-0993 DIRECTCURRENT ATTIC VENTEC13007964 EXISTING FLUSH ATTIC VENTVICINITY MAP 5208TAMPA W BLVD, TAMPA, FL 33634 ESS ENERGY STORAGE SYSTEM PVC PIPE VENT w ONE o FAX 0 EXT EXTERIOR _ METAL PIPE VENT CUSTOMER RESIDENCE: ti INT INTERIOR n3 SEAN LAURSEN T-VENT 38835 4TH AVE, ZEPHYRHILLS, MSP MAIN SERVICE PANEL u tN; NEW SATELLITE DISH _ FL, 33542 NTS NOT TO SCALE M Ave - 5>h <veAve TEL. (313) 838-2515 oc onrCENTER FIRE SETBACKS APN: 11-26-21-0010-1730£-0141 PRE-FAB PRE -FABRICATED _. "' '� a' PROJECT NUMBER: PSF POUNDS PER SQUARE FOOT � ��� HARDSC;APE � , .-, 802R-835LAUR Pv PHO T OVOLTAiC RSD RAPID SHUTDOWN DEVICE — PL— PROPERTY LINE � DESIGNER: (415) 580-6920 BK3 - SOLAR MODULES MIKE CHAVEZ TL TRANSF©RMERtEss SCALE: NTS TYP TYPICAL-_- __-.,.. ,_-_____ `. SHEET I 9 REV NAME DATE COMMENTS COVER SHEET LLANLANDSCAPE VOLTS � I S w REV: A 5l19l2O23 +--...-._._._.,.......-____.-.,_....._,..___-�SNR MOUNTPAGEsRAIT SNR MOUNT & SKIRT Template version 4 0 87 MCI IV a a ml m! PL rL rL rL o849 3 f STATE OF tY Ott tORIO 5/23/2023 ROOF INFO FRAMING INFO ATTACHMENT INFORMATION DESIGN CRITERIA Name Type Height Type Max 0C Detail Max Landscape Max Landscape Max Portrait Max Portrait Configuration MAX DISTRIBUTED LOAD: 3 PSF Span Spacing OC Spacing Overhang OC Spacing Overhang SNOW LOAD: 0 PSF AR-01 COMP SHINGLE - RLU 1-Story 2X6 RAFTERS IT- 3" 24" RL UNIVERSAL, SPEEDSEAL TRACK ON 6'- 0" 2'- 4" 4'- 0" 2'- 0" STAGGERED WIND SPEED: 138 MPH 3-SEC GUST. COMP, SEE DETAIL SNR-DC-00436 S.S. LAG SCREW AR-02 COMP SHINGLE - RLU 1 -Story 2X6 RAFTERS III - III, 24" RL UNIVERSAL, SPEEDSEALTRACK ON COMP, SEE 6'- 0" 2'- 4" 4'- 0" 2'- 0" STAGGERED 5/16"x4.5": 2.5" MIN. EMBEDMENT DETAIL SNR-DC-00436 AR-03 COMP SHINGLE - RLU 1-Story 2X6 RAFTERS 12'- 10" 24" RL UNIVERSAL, SPEEDSEAL TRACK ON COMP, SEE 6'- 0" 2'- 4" 4'- 0" 2'- 0" STAGGERED DETAIL SNR-DC-00436 DI - AR-01 SCALE: 0.010417 1'- t-12'-5"—�-15'—� AZIM: 180' PITCH: 21* ------ to N E si T-67YP- INSTALLERS SHALL NOTIFY ENGINEER OF No 84923 B S ANY POTENTIAL STRUCTURAL ISSUES A OBSERVED PRIOR TO PROCEEDING W1 ` I Z/ R-11 10'-5" INSTALLATION. tOR10 NAL T-6" 5/23/2023 D2 - AR-02 - SCALE: 1/8" = V-0" 1, AZIM: 90' 1 14'- 11 PITCH: 21' B I 10' -5" -e B ----------- B — ---------- B — ---------- B— 19 sunrun 1 ENGINEER ADDRESS: 225 BUSH ST, SUITE 1400 SAN FRANCISCO. CA 94104 0 P'949-383-0993 2' 6" EC13007964 5208 TAMPA W BLVD. TAMPA, FL 33634 PHONEG FAX 0 1IA 24'- 10" T-1 1 CUSTOMER RESIDENCE: SEAN LAURSEN D3 - AR-03 - SCALE: 0.010417 38835 4TH AVE, ZEPHYRHILLS, AZIM: 270' FL,33542 PITCH: 21' TEL. (813) 838-2515 V-Y E3 APN: 11-26-21-0010-17300-0141 T-511 67yp--� 1r) I PROJECT NUMBER: r) n n 802R-835LAUR DESIGNER: (415) 580-6920 ex3 MIKE CHAVEZ SHEET LAYOUT REV: A 5/19/2023 PAGE PV-3.0 11 cuffe"IMI c=am METER #- <-- DUKE ENERGY 4401985 UTILITY GRID SUPPLY SIDE TAP NOTE: TOTAL PV BACKFEED = 40A U-SED FOR INTERCONNECTION CALCULATIONS (N) LOCKABLE EXISTING 150A BLADE TYPE MAIN BREAKER FUSED AC (N) LOCKABLE SOLAREDGE TECHNOLOGIES: DISCONNECT BLADE TYPE SE760OH-USSN AC DISCONNECT 7600 WATT INVERTER EXISTING 150A MAIN PANEL FACILITY LOADS -------ZFACfL[TY 40A FUSES GROUND SQUARE D SQUARE D LOAD RATED DC DISCONNECT D222NRB DU222RB WITH AFCI, RAPID SHUTDOWN 3R, 60A 3R, 60A,2P COMPLIANT 120/240VAC 120/240VAC # CONDUIT CONDUCTOR NEUTRAL GROUND 0 NONE NONE NONE (1) 6 AWG BARE COPPER 1 NONE (4) 10 AWG PV WIRE NONE (1) 6 AWG BARE COPPER 2 3/4" EMT OR EQUIV. (4) 10 AWG TH HN/THWN-2 NONE (1) 8 AWG THHN/THWN-2 3 3/4" EMT OR EQUIV, (2) 8 AWG THHN/THWN-2 (1) 10 AWG THHN/THWN-2 (1) 8 AWG THHN/THWN-2 4 3/4" EMT OR EQUIV. (2) 6 AWG THHN/THWN-2 (1) 8 AWG THHN/THWN-2 NONE HANWHA Q-CELLS: Q.PEAK DUO BLK S440 OPTIMIZER CHARACTERISTICS: ML-G 10+ 405: 405 W MIN INPUT VOLTAGE: 8 VDC OPEN CIRCUIT VOLTAGE: 4506 V MAX INPUT VOLTAGE: 60 VDC MAX POWER VOLTAGE: 37.59 V MAX INPUT ISC: 145 ADC SHORT CIRCUIT CURRENT: 11A7A MAX OUTPUT CURRENT: 15 ADC SYSTEM CHARACTERISTICS - INVERTER I SYSTEM SIZE: 10125 W SYSTEM OPEN CIRCUIT VOLTAGE: 13 V SYSTEM OPERATING VOLTAGE: 380 V MAX ALLOWABLE DC VOLTAGE: 480 V SYSTEM OPERATING CURRENT- 2665 A SYSTEM SHORT CIRCUIT CURRENT: 30 A JUNCTION BOX PV MODULES OR EQUIVALENT"`, HANWHA Q-CELLS: Q.PEAK DUO BLK ML-G10+ 405 — ----- (25) MODULES OPTIMIZERS WIRED IN: 7---�(1) SERIES OF (13) OPTIMIZERS (1) SERIES OF (12) OPTIMIZERS SOLAREDGE POWER OPTIMIZERS S440 k Vl� �E No, 8 5111 WE S STATE OF ///////O/ONAL 0 !N/m t mWN0 EXPIRES: 2128/2025 SIGNED: 05/22/2023 Temnfatp vpminn 4 0 R7 ELECTRICAL SHOCK HAZARD WIN 2017: 690,13(B) DO NOT RELOCATE THIS OVERCURRENT DEVICE LABEL LOCATION: ADJACENT TO PV BREAKER (IF APPLICABLE). PER CODE(S): CEC 2019: 705.12(B)(2)(3)(b), NEC 2017: 705.12(B)(2)(3)(b) LABEL LOCATION: PHOTOVOLTAIC AC COMBINER (IF APPLICABLE), PER CODE(S): CEC 2019: 705A2(B)(2)(3)(c), NEC 2017: 705.12(B)(2)(3)(c) SOURCES: UTILITY '. A x SYSTEM LABEL LOCATION: UTILITY SERVICE Pill LABEL LOCATION: INTERIOR AND EXTERIOR DC CONDUIT EVERY 10 FT, AT EACH TURN, ABOVE AND BELOW PENETRATIONS, ON EVERY JB(PULL BOX CONTAINING DC CIRCUITS. PER CODE(S): CEC 2019: 690.31(G)(3), 690.31(G)(4), NEC 2017: 690.31(G)(3), 690.31(G)(4) IFC 2012: 605.11.1.4 LABEL LOCATION: AC DISCONNECT(S), PHOTOVOLTAIC SYSTEM POINT OF INTERCONNECTION. PER CODE(S): CEC 2019: 690.54, NEC 2017: 690.54 LABEL LOCATION: INVERTER(S), DC DISCONNECT(S). PER CODE(S): CEC 2019: 690.53, NEC 2017: 690.53 LABEL LOCATION: INSTALLED WITHIN S OF RAPID SHUT DOWN SWITCH PER CODE(S): CEC 2019: 690.56(C)(3), NEC 2017: 690.56(C)(3), IFC 2012: 605.11.1, IFC 2018: 1204.5.3, CFC 2019: 1204.5.3 im SHOCK HAZARD IN THE LABEL LOCATION: ON OR NO MORE THAT 1 M (3 FT) FROM THE SERVICE DISCONNECTING MEANS TO WHICH THE PV SYSTEMS ARE CONNECTED. PER CODE(S): CEC 2019: 690.56(C)(1)(a), NEC 2017: 690.56(C)(1)(a) NOTES AND SPECIFICATIONS: SIGNS AND LABELS SHALL MEET THE REQUIREMENTS OF THE NEC 2017 ARTICLE I 10.21(B), UNLESS SPECIFIC INSTRUCTIONS ARE REQUIRED BY SECTION 690, OR IF REQUESTED BY THE LOCAL AHJ. SIGNS AND LABELS SHALL ADEQUATELY WARN OF HAZARDS USING EFFECTIVE WORDS, COLORS AND SYMBOLS, LABELS SHALL BE PERMANENTLY AFFIXED TO THE EQUIPMENT OR WIRING METHOD AND SHALL NOT BE HAND WRITTEN. LABEL SHALL BE OF SUFFICIENT DURABILITY TO WITHSTAND THE ENVIRONMENT SIGNS AND LABELS SHALL COMPLY WITH ANSI Z535.4-201 1, PRODUCT SAFETY SIGNS AND LABELS, UNLESS OTHERWISE SPECIFIED. DO NOT COVER EXISTING MANUFACTURER LABELS. t gtttttlltlEt((rt(`` No, 85111 a w STATE OF �rtrr(ittitttttttt EXPIRES: 2/28/2025 SIGNED: 05/22/2023