HomeMy WebLinkAbout23-6328Address: 39041 Blue Jay Ave Zephyrhills, FL 33542 Phone: Building Valuation: $0.00 Electrical Valuation: $15,795.00 Mechanical Valuation: Plumbing Valuation: Total Valuation: $15,795.00 Total Fees: $118.98 Amount Paid: $1118.98 Date Paid: 5/25/2023 3:41:04PM Electrical Permit Fee $118.98 I sue Date: 05/25/2023 39041 Blue Jay Avenue SERVICES INC REINSPECTION FEES: (c) With respect to Reinspection fees will comply with Florida Statute 553.80(2)(c) the local government shall impose a fee of four times the amount of the fee imposed for the initial inspection or first reinspection, whichever is greater, for each subsequent reinspection. ',4otice: In addition to the requirements of this permit, there may be additional restrictions applicable to this property that ,nay be found in the public records of this counq,", entities such as water management, state agencies or federal agencies. "Warning to owner: Your failure to record a notice of commencement may result in your paying twice for improvements to your property. If you intend to obtain financing, consult with your lender or an attorney Ir 7#7 - ornpany Application. All work shall be performed in accordance with City Codes and Ordinances. NO OCCUPANCY BEFORE C.O. NO OCCUPANCY BEFORE C.O. ONIRAITOR SIGNATURE PEfIT OFFIC - Eg— PERMIT EXPIRES IN 6 MONTHS WITHOUT APPROVED INSPECTION CALL FOR INSPECTION - 8 HOUR NOTICE REQUIRED PROTECT CARD FROM WEATHE'a 813-780-0020 City of Zephyrhilts Permit Application Fax -la 34BEI-ooz1 Building Department 0086 y.+r']tw�r r. :w=y1Jr n Owner's NameRIJ 1. # # 4M1 SIR t, ry # Address *. it <. .Ili �. Owner Phone Fee Simple'ndeholder Name Owner Phone Number Fee Simple Titleholder Address JOB ADDRESS FS_ 79 [gig (OBTAINED FROM PROPERTY TAX NOTICE) WORK PROPOSED NEW CONSTR � ADDIALT x SIGN DEMOLISH INSTALL REPAIR W.K.....dristallation of a roof -mounted photovoltaic solar panel system. BUILDING SIZE [ ----------------- 7 SQ FOOTAGE = HEIGHT [—_:]BUILDING $ _. VALUATION OF TOTAL CONSTRUCTION ELECTRICAL $` AMP SERVICE PROGRESS ENERGY = W.R.E.0 PLUMBING $ =MECHANICAL I$ VALUATION OF MECHANICAL INSTALLATION GAS ROOFING L] SPECIALTY = OTHER FINISHED FLOOR ELEVATIONSw ZONE AREA F­IYES NO xSunrun Installation Services, Inc. InstallationSunrun Services, Inc. RESIDENTIAL Attach (2) Plot Plans; (2) sets of Building Plans; (1) set of Energy Forms; R-O-W Permit for new construction, Minimum ten t.� k (10) working days after submittal date. Required onsite, Construction Plans, Stormwater Plans w/ Silt Fence installed, Work Permit forge projects COMMERCIAL e:. Attachcomplete sets of Building t Plansplus a Life Safety Page; of !Forms,a PenTilt for now construction, requirementsMinimum ten (10) working days after submittal date. Required onsito, Construction Plans, Stormwater Plans w/ Silt Fence Installed, Sanitary Facilities & I clumpster. Site Work Permit for all new projects. All commercial compliance SIGN PERMIT Attach (2) sets of f t -PROPERTY SURVEYrequired for all NEW construction. notarizedFill out application completely. Owner & Contractor sign back of application, if over $2500, a Notice of Commencement Is required, (AIC upgrades over $7500) et Agent (for the contractor) or Power of Attorney (for the owner) would be someone with notarized letter from owner authorizing same OVER THE COUNTER PERMITTING (copy of contract required) Reroofs if shingles Sewers Service Upgrades A/C Fences (PlottSurvey/F e) Driveways -Not over Counter if on public roadways needs ROW 813-780-0020 City of Zephyrhills Permit Application Fax-813-7s0-0021 5ui ding Department NOTICE OF DEED RESTRICTIONS: The undersigned understands that this permit may be subject to"d"T restrictions" which may be more restrictive than County regulations. The undersigned assumes responsibility for compliance with any applicable deed restrictions. UNLICENSED CONTRACTORS AND CONTRACTOR RESPONSIBILITIES: if the owner has hired a contractor or contractors to undertake work, they may be required to be licensed in accordance with state and local regulations. If the contractor is not licensed as required by law, both the owner and contractor may be cited for a misdemeanor violation under state law. If the owner or intended contractor are uncertain as to what licensing requirements may apply for the intended work, they are advised to contact the Pasco County Building Inspection Division --Licensing Section at 727-847- 8009. Furthermore, if the owner has hired a contractor or contractors, he is advised to have the contractor(s) sign portions of the "contractor all of this application for which they will be responsible. If you, as the owner sign as the contractor, that may be an Indication that he is not prop" licensed and is not entitled to permitting privileges in Pasco County. TRANSPORTATION IMPACTIUTILITIES IMPACT AND RESOURCE RECOVERY FEES: The undersigned understands that Transportation Impact Fees and Recourse Recovery Fees may apply to the construction of new buildings, change of use in existing buildings, or expansion of existing buildings, as specified In Pasco County Ordinance number 89-07 and 90-07, as amended, The undersigned also understands, that such fees, as may be due, will be identified at the time of permitting. It is further understood that Transportation Impact Fees and Resource Recovery Fees must be paid prior to receiving a "certificate of occupancy' or final power release. If the project does not Involve a certificate of occupancy or final power release, the fees must be paid prior to permit issuance. Furthermore, if Pasco County Water/Sewer Impact fees are due, they must be paid prior to permit issuance In accordance with applicable Pasco County ordinances. CONSTRUCTION LIEN LAW (Chapter 713, Florida Statutes, as amended): if valuation of work is $2,500.00 or more, I certify that 1, the applicant, have been provided with a copy of the 'Florida Construction Lion Law—Homeawner's Protection Guide' prepared by the Florida Department of Agriculture and Consumer Affairs. If the applicant is someone other than the 'owner", I certify that I have obtained a copy of the above described document and promise in good faith to deliver it to the "owner" prior to commencement. CONTRACTOWSIOWNER'S AFFIDAVIT: I certify that all the information in this application is accurate and that all work will be done in compliance with all applicable laws regulating construction, zoning and land development. Application is hereby made to obtain a permit to do work and installation as indicated- I certify that no work or installation has commenced prior to issuance of a permit and that all work will be performed to meet standards of all laws regulating construction, County and City codes, zoning regulations, and land development regulations in the jurisdiction. I also certify that I understand that the regulations of other government agencies may apply to the intended work, and that it is my responsibility to identify what actions I must take to be in compliance. Such agencies include but are not limited to: - Department of Environmental Protection -Cypress Bayheads, Wetland Areas and Environmentally Sensitive Lands, Water/Wastewater Treatment. Watercourses. Army Corps of Engineers -Seawalls, Docks, Navigable Waterways. Department of Health & Rehabilitative Services/Environmental Health Unit -Wells, Wastewater Treatment, Septic Tanks, US Environmental Protection Agency -Asbestos abatement, Federal Aviation Authority -Runways, I understand that the following restrictions apply to the use of fill: - Use of fill is not allowed in Flood Zone "V" unless expressly permitted. - If the fill material is to be used in Flood Zone 'A", it is understood that a drainage plan addressing a "compensating volume" Will be submitted at time of permitting which is prepared by a professional engineer licensed by the State of Florida. - If the fill material is to be used in Flood Zone "A" in connection with a permitted building using stem wall construction, I certify that fill Will be used only to fill the area within the stem wall, - If fill material is to be used in any area, I certify that use of such fill will not adversely affect adjacent properties, If use of fill is found to adversely affect adjacent properties, the owner may be cited for violating the conditions of the building permit issued under the attached permit application, for lots less than one (1) acre which are elevated by fill, an engineered drainage plan is required, If I am the AGENT FOR THE OWNER, I promise in good faith to inform the owner of the permitting conditions set forth in this affidavit prior to commencing construction. I understand that a separate permit may be required for electrical work, plumbing, signs, wells, pools, air conditioning, gas, or other installations not specifically included in the application. A permit issued shall be construed to be a license to proceed with the work and not as authority to violate, cancel, altar, or set aside any provisions of the technical codes, nor shall issuance of a permit prevent the Building Official from thereafter requiring a correction of errors in plans, construction or violations of any codes. Every permit issued shall become invalid unless the work authorized by such permit Is commenced within six months of permit Issuance, or R work authorized by the permit is suspended or abandoned for a period of six (6) months after the time the work is commenced. An extension may be requested, in writing, from the Building Official for a period not to exceed ninety (90) days and will demonstrate justifiable cause for the extension, If work ceases for ninety (90) consecutive days, the job is considered abandoned, A. - gm 1. 1 Name of Notary typed, printed or stamped M lama of Notary d, pinned or stem SP j Jii Tho�TANY L. DEBiw OUVER Commission # HH 25909 Expires May 1, 2026 Astra v.1,782 May 23, 2023 sunr U n WS CAT 1 Subject : Structural Certification for Proposed Residential Solar Installation. NIVAIEW kV James Matthew Walsh, State of Florida, Job Number: 802R-041 COX2; Rev A E N S, < Professional Engineer, License No. 84923 Client: Ronald Cox 4 0 8 92 This item has been digitally signed and sealed by James Matthew Walsh, PE on 5/23/2023 Address: 39041 Blue Jay Zeph, F542 Ave, yrhillsIL 33 fal using a Digital Signature. Printed copies of this STATE OF document are not considered signed and sealer and the SHA authentication code must be to -IV N y verified on electronic copies. Attn: To Whom It May Concern N At- 1114 P0 Afield observation of the existing structure at the address indicated above was performed by a site survey team from Sunrun. Structural evaluation of the loading was based on the site observations and the design criteria listed below. Design Criteria: • 2020 FBC (7th Ed.) AMENDMENTS TO 2018 IRC/IBC/IEBC, 7-16 ASCE & 2018 NDS • Basic (Category 11) Wind Speed V = 138 mph, Exposure B Ground Snow Load = 0 psf Based on this evaluation, I certify that the alteration to the existing structure by the installation of the PV system meets the requirements of the applicable existing and/or new building code provisions referenced above. Additionally, I certify that the PV module assembly including all attachments supporting it have been reviewed to be in accordance with the manufacturer's specifications. 225 Bush St. Suite 1400 San Francisco, CA 94104 ----- '251 `1 TOPOPANDPV Me" Warran Q CELLS p1nd-1 & Periarmarice Yield Security BREAKING THE 20% EFFICIENCY BARRIER Q.ANTUM DUO Z Technology with zero gap cell layout boosts module efficiency up to 21,4%. THE MOST THOROUGH TESTING PROGRAMME IN THE INDUSTRY Q CELLS is the first solar module manufacturer to pass the most comprehen sine quality programme in the industry: The new "Quality Controlled PV` of the independent certification institute TOV Rheinland, INNOVATIVE ALL-WEATHER TECHNOLOGY Optimal yields, whatever the weather with excellent low -light and temperature behavior. ENDURING HIGH PERFORMANCE Long-term yield security with Anti LID Technology, Anti PID Technology', Hot -Spot Protect and Traceable Quality Tra.QTM. EXTREME WEATHER RATING C/Z High-tech aluminum alloy frame, certified for 77 high snow (5400 Re) and wind loads (4000 Pa). V A RELIABLE INVESTMENT u-_V Inclusive 26-year product warranty and 25-year linear performance warranty2. APT test conditions according to IEC/ TS 62804-12015, method A ( -1500V, 96h) See data sheet on rear for further information THE IDEAL SOLUTION FOR: 611PRooftop arrays on residential buildings Engineered in Germany GICELLS MECHANICAL SPECIFICATION 74.0in x 41.lin x 1.26in (including frame) -- Ja.P" jiaJ9 mmj -_..- (1879mm x 1045 mm x 32mm) -� _ vs.6•(39a.s mn) .... ... ... ... ..... .... ... .. .. . ... ..... _.. ..... .,.. ...... eta 1098 ) ___ 48.51bs (22.O kg) _•_.._ ._. Q 13 in (3.2 mm) thermally pre- stressed glass with ruPmm) � ant) -reflection technology 0.R6wM4P a°OPia'f,s .. Compositefilm 39.1(a96 mm) Black anodized aluminum ,,, -- . ... .. _... . ,.. _, ...._ 0 1-pans III) 6 x 22 monocrystalline Q.ANTUM solar half cells 2 09-3.98 in x 1,26-2 36 in x 0.59-0.71 in (53 101 mm x 32-60 mm x 15-18 mm), IP67 with bypass diodes nae.r (izsP mm) 4 mm2 Solar cable; (+) �49.2in (1250 mm), ( ) >_49.21n (1250 mm) ... „ .. .. .. i a.rwwwan oom meraL ra + ,..:'Steubli MC4; IP68 OETAILPP.63'ry8mm-)(- ELECTRICAL CHARACTERISTICS .... POWER CLASS 396 _400 405 410 415__ PMPP (W] 395 400 405 410 415 _ _ _ .. Isc [A] 11A3 - 11.16 11.19 11.22 11.26 oc [V] 45.03 45,06 45,09 45.13 45,16 �1 ! MPP [A] _ 10.58 10.64� 10.70 10.76 10.82 « _ vMPP [V] 3732 37.59 3785 38.11 38.37 _.. q (%J a20A ?20.4 >_20.6 z20.9 5 ; P PP [W] 296.4 300A 303.9 307.6 311.4 Isc [A] 8.97 8.99 9.02 9.04 9.07 r Voc IV] 42.46 42.49 42.52 42.56 42.59 IMPP [A]. 8,33 8.38 8.43 8.48.... 8.53 VMPP IV] 35,59 35.82 36.04 36.27 36.49 'Measurement tolerances P_±3%; (sc; Voc t5%at STC:1000 W/m2, 25t2°C, AM 1.5 according to IEC 60904-3 •'800W/m2, NMOT, spectrum AM 1.5 Q CELLS PERFORMANCE WARRANTY PERFORMANCE AT LOW IRRA0IANCE _._____ _._____.____- At least 98% of nominal power during first year. Thereafter max. 0.5% ------------ degradation per year. At least93.5% of nominal power up to 10 years. At "` least 86% of nominal power up to 25years. - i - +----] All data within measurement toleranc t° es. Full warranties in accordance with eP M 400 600 600 I000 the warranty terms of the Q CELLS sales organisation of your respective ` o to a :o country. Typical module performance under low Irradiance conditions in comparison to STC conditions (25°C,1000 W/m2) TEMPERATURE COEFFICIENTS _ [%jK] +0.04 [%/KI -0.27 y [%/K] 0,34 NMQT . [IF] .. 109t5.4(43t3°C)_ PROPERTIES FOR SYSTEM DESIGN [V] 1000 (IEC)/1000 (UL) Class 11 [a pC] _ 20 _.. TYPE 2 [Ibs/ft2] 75 (3600 Pa)/55 (2660 Pa) -40IFupto+1857 [Ibs/ft2] 113(5400Pa)/84(4000Pa) (-40°Gupta+85°C) 3See Installation Manual . QUALIFICATIONS AND CERTIFICATES PACKAGING INFORMATION UL61730, CE-compliant, Quality Controlled PV -TUV Rheinland, ib ®-CI 140 H{CI IEC 61215:2016, IEC 61730:2016, ® - --- - - -- - U.S.Patent No-9,893,215(sol�rcelisj, rirvan.mw10,a 76.4in 43.3in 48.Oin 1656lbs 24 24 32 QCPVCertification ongoing, O U5 1940mm 1100mm 1220mm 751kg pallets pallets modules cenmea _.... UL 61730 ID 1111RTa3>) ... Note: Installation instructions must be followed. See the installation and operating manual or contact our technical service department for further information on approved installation and use of this product. Hanwhe 0 CELLS America Inc. 400 Spectrum Center Drive, Suite 1400, Irvine, CA 92618, USA I TEL +1949 748 59 961 EMML inquiry@us.q-cells.com I L? E8 www.q-cells.us SHEETINDEX LEGEND SCOPE OF WORK GENERAL NOTES PAGE # DESCRIPTION - SYSTEM SIZE: 81OOW DC, 600OW AC ® ALL WORK SHALL COMPLY WITH 2O20 FBC (7TH ED.) AMENDMENTS TO 2018 PV®1.O COVER SHEET SE SERVICE ENTRANCE - MODULES: (20) HANWHA Q-CELLS: Q.PEAK DUO BLK IRC/IBC/IEBC, MUNICIPAL CODE, AND ALL MANUFACTURERS' LISTINGS AND ML-G10+ 405 INSTALLATION INSTRUCTIONS. PV-2.O SITE PLAN e INVERTERS: (1) SOLAREDGE TECHNOLOGIES: ® PHOTOVOLTAIC SYSTEM WILL COMPLY WITH NEC 2017, PV-3.O LAYOUT &I MAIN PANEL SE600OH-USSN RACKING: TOPSPEED, SEE DETAIL SNR-DC-30004 m ELECTRICAL SYSTEM GROUNDING WILL COMPLY WITH NEC 2017, PV-4.O ELECTRICAL SP SUB -PANEL - PHOTOVOLTAIC SYSTEM IS UNGROUNDED. NO CONDUCTORS ARE SOLIDLY PV-5.O SIGNAGE GROUNDED IN THE INVERTER, SYSTEM COMPLIES WITH 690.35. LC PV LOAD CENTER MODULES CONFORM TO AND ARE LISTED UNDER UL 1701 ® INVERTER CONFORMS TO AND IS LISTED UNDER UL 1741. SM SUNRUN METER RACKING CONFORMS TO AND IS LISTED UNDER UL 2703. PM DEDICATED PV METER ® SNAPNRACK RACKING SYSTEMS, IN COMBINATION WITH TYPE I, OR TYPE II MODULES, ARE CLASS A FIRE RATED, ��ti�tttllrrrrrrr INV INVERTER(S )RAPID SHUTDOWN REQUIREMENTS MET WHEN INVERTERS AND ALL ,�```` A'® V 1 CONDUCTORS ARE WITHIN ARRAY BOUNDARIES PER NEC 690.12(1). LE-2 DISCONNECT(S) - CONSTRUCTION FOREMAN TO PLACE CONDUIT RUN PER 690.31(G). No. 85111 DC DC DISCONNECT(S) ® ARRAY DC CONDUCTORS ARE SIZED FOR DEBATED CURRENT. Y =, STATE 0 FF ® 11A7 AMPS MODULE SHORT CIRCUIT CURRENT. C o p CB IQ COMBINER BOX ® 17.45 AMPS DEBATED SHORT CIRCUIT CURRENT [690.8 (A) $ 690.8 (B)]. ONAtt+`` ABBREVIATIONSF- ­1 EXPIRES: 2/28/2025 SIGNED: 05/15/2023 INTERIOR EQUIPMENT A AMPERE L _J SHOWN AS DASHED AC ALTERNATING CURRENT AFC ARC FAULT CIRCUIT INTERUPTER ........... CHIMNEY sunrun AZIM AZIMUTH ENGINEER ADDRESS: 225 BUSH ST, SUITE 1400 COMP COMPOSITION ATTIC VENT SAN FRANCISCO, CA 94104 P: 949-383-0993 DC DIRECT CURRENT FLUSH ATTIC VENT EG13007964 PVC PIPE VENT VICINITY (E) EXISTING 6208 TAMPA W BLVD, TAMPA, FL 33634 PHONE o ESS ENERGY STORAGE SYSTEM METAL PIPE VENT %; FAX 0 EXT EXTERIOR y T-VENT CUSTOMER RESIDENCE: INT INTERIOR BONALD COX MSP MAIN SERVICE PANEL' � SATELLITE DISH 39041 BLUE JAY AVE, (N) NEW a ZEPHYRHILLS, FL, 33542 NTS NOT To SCALE FIRE SETBACKS f TEL. (813) 305-9328 OC ON CENTER -� r APN: 13-26-21-0100-00000-0240 PRE-FAB PRE -FABRICATED HARDSCAPE f� PROJECT NUMBER: PSF POUNDS PER SQUARE FOOT b> 802R-041 COX2 Pv PHOTOVOLTAIC — PL— PROPERTY LINE ` ��� SOLAR MODULES r „rF DESIGNER: 415 580 6920 ex3 RSC RAPID SHUTDOWN DEVICE KENT VALERIO TL TRANSFORMERLESS SCALE: NTS TYP E '� r SHEET TYPICAL 1 REV NAME DATE COMMENTS COVER SHEET V VOLTS £ I W WATTS REV: A 5/15/2023 LAN LANDSCAPE -_-- TOPSPEED MOUNT "' -�': ;, ' � PAGE - 0 POR PORTRAIT a° ✓ � - -. Template version 4,0.87 � fi • BLUE JAY AVE ow? 7-11t f STATE OF 5/18/2023 Name Type AR-01 COMP SHINGLE - TOPSPEED 01'AR-01-SCALE: 3M6r=1'-O^ sm HM 7'-11^ Minimum Nuumber of Mounts per Max Landscape Max Portrait Up -Slope Edge(Landscape Overhang Overhang 13'-11^ ENGINEER ADDRESS PHONEO FAX 0 CUSTOMER RESIDENCE: 39041 BLUE JAY AVE, INSTALLERS SHALL NOTIFY ENGINEER OFANY PROJECT NUMBER: POTENTIAL STRUCTURAL ISSUES OBSERVED PRIOR TOPROCEEDING NVINSTALLATION. MOUNT NUMBER FOR LEADING D0WNSLOPE EDGE SHALL MATCH REQUIREMENTS LISTED ABOVE INSTALL PER TUPSPEED5,O SHEET INSTALLATION MANUAL. LAYOUT CONTRACTOR MAY SUBSTITUTE SNAPNRACK DECKTRACKMOUNTS (SNRDETAIL METER #: <-- DUKE ENERGY 4505885 UTILITY GRID SUPPLY SIDE TAP (N) LOCKABLE EXISTING 200A BLADE TYPE MAIN BREAKER FUSED AC (N) LOCKABLE SOLAREDGE TECHNOLOGIES: DISCONNECT BLADE TYPE SE600OH-USSN AC DISCONNECT 6000 WATT INVERTER 13' EXISTING 200A MAIN PANEL FACILITY LOADS 35A FUSES FACILITY GROUND SQUARE D SQUARE D LOAD RATED DO DISCONNECT D222NRB DU222RB WITH AFCI, RAPID SHUTDOWN `J3R,60A 3R, 60A,2P COMPLIANT 120/240VAC 120/240VAC JUNCTION BOX PV MODULES OR EQUIVALENT HANWHA Q -CELLS: Q.PEAK DUO BLK ML-G10+ 405 (20) MODULES v OPTIMIZERS WIRED IN: (1) SERIES OF (10) OPTIMIZERS (1) SERIES OF (10) OPTIMIZERS SOLAREDGE POWER OPTIMIZERS S440 CONDUIT SCHEDULE # CONDUIT CONDUCTOR NEUTRAL GROUND 0 NONE NONE NONE (1) 6 AWG BARE COPPER 1 NONE (4) 10 AWG PV WIRE NONE (1) 6 AWG BARE COPPER 2 3/4" EMT OR EQUIV. (4) 10 AWG THHN/THWN-2 NONE (1) 8 AWG THHN/THWN-2 3 3/4" EMT OR EQUIV. (2) 8 AWG THHN/THWN-2 (1) 10 AWG THHN/THWN-2 (1) 8 AWG THHN/THWN-2 4 3/4" EMT OR EQUIV. (2) 6 AWG THHN/THWN-2 (1) 8 AWG THHN/THWN-2 ONE MODULE CHARACTERISTICS S440 OPTIMIZER CHARACTERISTICS: HANWHA Q-CELLS: Q.PEAK DUO BLK MIN INPUT VOLTAGE 8 VDC ML-G10+ 405: 405 W MAX INPUT VOLTAGE: 60 VDC OPEN CIRCUIT VOLTAGE: 4534 V MAX INPUT ISC: 14.5 ADC MAX POWER VOLTAGE: 37.39 V MAX OUTPUT CURRENT: 15 ADC SHORT CIRCUIT CURRENT: 1117A SYSTEM SIZE: 8100 W SYSTEM OPEN CIRCUIT VOLTAGE: lov SYSTEM OPERATING VOLTAGE: 380 V MAX ALLOWABLE DC VOLTAGE: 480 V SYSTEM OPERATING CURRENT: 2132 A SYSTEM SHORT CIRCUIT CURRENT: 30 A It II If I I/,', ////" QI A Vl� No. 8 5111 STATE OF 0 P, o"Iflillow EXPIRES: 2/28/2025 SIGNED: 05/15/2023 Template version —4,0,67 ELECTRICAL SHOCK HAZARD TERMINALS ON LINE AND LOAD SIDES MAY BE ENERGIZED IN THE OPEN POSITION 2017: 690.13(B) RELOCATE DO NOT OVERCURRENT DEVICE LABEL LOCATION: ADJACENT TO PV BREAKER (IF APPLICABLE). PER CODE(S): CEC 2019: 705.12(B)(2)(3)(b), NEC 2017: 705,12(13)(2)(3)(b) LOCATION:LABEL LABEL LOCATION: PHOTOVOLTAIC AC COMBINER (IF APPLICABLE). PER CODE(S): CEC 2019: 705.12(B)(2)(3)(c), NEC 2017: 705.12(B)(2)(3)(c) DUAL POWER SUPPLY SOURCES: ,y AND PV II I SOLAR„r I SYSTEM LABEL LOCATION: UTILITY SERVICE METER AND MAIN SERVICE PANEL. PER CODE(S): CEC 2019: 705.12(B)(3), NEC 2017: 705.12(B)(3) LABEL LOCATION: INTERIOR AND EXTERIOR DC CONDUIT EVERY 10 FT, AT EACH TURN, ABOVE AND BELOW PENETRATIONS, ON EVERY JB/PULL BOX CONTAINING DC CIRCUITS. PER CODE(S): CEC 2019: 690.31(G)(3), 690.31(G)(4), NEC 2017: 690.31(G)(3), 690,31(G)(4) IFC 2012: 605.11.1A LABEL LOCATION: AC DISCONNECT(S), PHOTOVOLTAIC SYSTEM POINT OF INTERCONNECTION. PER CODE(S): CEC 2019: 690.54, NEC 2017: 690.54 m LABEL LOCATION: INVERTER(S), DC DISCONNECT(S). PER CODE(S): DEC 2019: 690,53, NEC 2017: 690,53 0 *� SWrrCH TO THE "OFF" SHOCK HAZARD IN THE LABEL LOCATION: ON OR NO MORE THAT 1 M (3 FT) FROM THE SERVICE DISCONNECTING MEANS TO WHICH THE PV SYSTEMS ARE CONNECTED. PER CODE(S): CEC 2019: 690.56(C)(1)(a), NEC 2017: 690.56(C)(1)(a) NOTES AND SPECIFICATIONS: 110.21(B), UNLESS SPECIFIC INSTRUCTIONS ARE REQUIRED BY SECTION 690, OR IF REQUESTED BY THE LOCAL AHJ. SIGNS AND LABELS SHALL ADEQUATELY WARN OF HAZARDS USING EFFECTIVE WORDS, COLORS AND SYMBOLS, LABELS SHALL BE PERMANENTLY AFFIXED TO THE EQUIPMENT OR WIRING METHOD AND SHALL NOT BE HAND WRITTEN, SIGNS AND LABELS SHALL COMPLY WITH ANSI Z535.4-201 1, PRODUCT SAFETY SIGNS AND LABELS, UNLESS OTHERWISE SPECIFIED. DO NOT COVER EXISTING MANUFACTURER LABELS, t��`�`tt t i n t ttrrrrj 4 A._Vl� No, 85111 a W STATE OF "; /i/,�`OCVALEt 00�y� EXPIRES: 2/28/2025 SIGNED: 05/15/2023