Loading...
HomeMy WebLinkAbout23-6377it of Zephyrhills om "M 9 5M 5335 Eighth Street k M - 1 Zephyrhills, FL 33542 =-LCMISC-006377-2023 Phone: (813) 780-0020 Fax: (813) 780-0021 Issue Date: 06/07/2023 6 'N50l2I1,1212111MI 12 26 21 0040 00300 0120 5316 Satsuma Drive in, N Name: LAURA COTTY Permit Type: Electric Service Replacement/M Contractor: VOLTAGE PRO SOLAR Class of Work: Add/Alter Residential Address: 5316 Satsuma Drive ZEPHYRHILLS, FLORIDA 33542 Building Valuation: $0.00 Electrical Valuation: $22,600.00 Ck, Phone: (813) 312-9650 Mechanical Valuation: Plumbing Valuation: Total Valuation: $22,600.00 Total Fees: $220.50 Amount Paid: $153.00 Date Paid: 6/7/2023 3:00:28PM J 'wom 'g, Z-g 1,01 01 M., 401001",, g"g" INSTALLATION ROOF MOUNT PV SOLAR** REVISED PLAN GIVEN FOR WATTAGE wg� .............. 1-�' SHINN N Electrical Permit Fee $153,00 BP REVISION FEE $67.50 REINSPECTION FEES: (c) With respect to Reinspection fees will comply with Florida Statute 553.80(2)(c) the local government shall impose a fee of four times the amount of the fee imposed for the initial inspection or first reinspection, whichever is greater, for each subsequent reinspection. Notice: In addition to the requirements of this permit, there may be additional restrictions applicable to this property thal may be found in the public records of this county, and there may be additional permit required from other governmental entities such as water management, state agencies or federal agencies. "Warning to owner: Your failure to record a notice of commencement may result in your paying twice fim 0 ��F11111111111111111111 1111111 1111111 111111 "Ili ilI 1111 11 . . # . Complete Plans, Specifications add fee Must Accompany Application. All work shall be performed ir accordance with City Codes and Ordinances. NO OCCUPANCY BEFORE C.O. NO OCCUPANCY BEFORE C.O. CONTRACTOR SIGNATURE PEfIT OFFICEf) 5335 Eighik Street Zephyrhills, FL 33542 Phone: (813) 780-0020 Fax: (813) 780-0021 Issue Date: 06/07/2023 REINSPECTION FEES: (c) With respect to Reinspection fees will comply with Florida Statute 553.80(2)(c) the local government shall impose a fee of four times the amount of the fee imposed for the initial inspection or first reinspection, whichever is greater, for each subsequent reinspection. Notice: In addition to the requirements of this permit, there may be additional restrictions applicable to this property that may be found in the public records of this county, and there may be additional permit required from other governmental entities such as water management, state agencies or federal agencies, E:1=M?T2n111 Complete Plans, Specifications add fee Must Accompany Application. All work shall be performed I accordance with City Codes and Ordinances. NO OCCUPANCY BEFORE C,O. NO OCCUPANCY BEFORE C.O. C R SIGNATURE PIE IT OFFICE PERMIT EXPIRES IN 6 MONTHS WITHOUT APPROVED INSPECTIO CALL FOR INSPECTION - 8 HOUR NOTICE REQUIRED PROTECT CARD FROM WEATHER i 813-780-0020 City of Zephyrhills Permit Application Fax-813-780-0021 Building Department Date Received Phone Contact for Permitting If 9 1 1 9 a I i V Owner's Name Owner Phone Number Owner's Address Owner Phone Number Fee Simple Titleholder Name Owner Phone Number Fee Simple Titleholder Address JOB ADDRESS LOT# SUBDIVISION PARCEL to# L 0 () Ll 0 -D& :�o C) (OBTAINED FROM PROPERTY TAX NOTICE) WORK PROPOSED NEW CONSTR ADDIALT SIGN DEMOLISH El INSTALL REPAIR PROPOSED USE SFR COMM OTHER V, TYPE OF CONSTRUCTION BLOCK FRAME STEEL DESCRIPTION OF WORK L) BUILDING SIZE SO FOOTAGE = HEIGHT [�UILDING VALUATION OF TOTAL CONSTRUCTION E�ELECTRICAL L2ia (I �00 AMP SERVICE PROGRESS ENERGY W.R.E.C. PLUMBING -------------------- =MECHANICAL VALUATION OF MECHANICAL INSTALLATION =GAS ROOFING SPECIALTY = OTHER FINISHED FLOOR ELEVATIONS FLOOD ZONE AREA =YES NO BUILDER COMPANY SIGNATURE REGISTERED FEE CURREN =Y I =N Address License # gg ELECTRICIAN COMPANY �t (V Le- &64 6 ,tti fVv— SIGNATURE REGISTERED FEE CURREN 2-7-2- Address h Y7 a_5 5 vtju, , 0�;- License # 4? PLUMBER COMPANY L!! SIGNATURE REGISTERED YIN FEE CURREN Y/N Address License# MECHANICAL COMPANY SIGNATURE REGISTERED LILN FEE CURREN YIN Address License #F— OTHER COMPANY E SIGNATURE REGISTERED ;YI ;NFEE �GURRE�NY I Address License # RESIDENTIAL Attach (2) Plot Plans; (2) sets of Building Plans; (1) set of Energy Forms; R-O-W Permit for new construction, Minimum ten (110) working days after submittal date. Required onsite, Construction Plans, Stormwater Plans wl Silt Fence installed, Sanitary Facilities & I dumpster; Site Work Permit for subdivisionsllarge projects COMMERCIAL Attach (2) complete sets of Building Plans plus a Life Safety Page; (1) set of Energy Forms, R-O-W Permit for new construction. Minimum ten (10) working days after submittal date. Required onsite, Construction Plans, Stormwater Plans wl Silt Fence installed, Sanitary Facilities & 1 dumpster. Site Work Permit for all new projects. All commercial requirements must meet compliance SIGN PERMIT Attach (2) sets of Engineered Plans. ****PROPERTY SURVEY required for all NEW construction. Directions: Fill out application completely. Owner & Contractor sign back of application, notarized If over $2500, a Notice of Commencement is required. (A/C upgrades over $7500) — Agent (for the contractor) or Power of Attorney (for the owner) would be someone with notarized letter from owner authorizing same OVER THE COUNTER PERMITTING (copy of contract required) Reroofs if shingles Sewers Service Upgrades A/C Fences (Plot/Survey/Footage) Driveways -Not over Counter if on public roadways -needs ROW 813-780-0020 City of Zephyrhills Permit Application Fax-813-780-0021 Building Department NOTICE OF DEED RESTRICTIONS: The undersigned understands that this permit may be subject to "deed" restrictions" which may be more restrictive than County regulations, The undersigned assumes responsibility for compliance with any applicable deed restrictions. UNLICENSED CONTRACTORS AND CONTRACTOR RESPONSIBILITIES: If the owner has hired a contractor or contractors to undertake work, they may be required to be licensed in accordance with state and local regulations. If the contractor is not licensed as required by law, both the owner and contractor may be cited for a misdemeanor violation under state law, If the owner or intended contractor are uncertain as to what licensing requirements may apply for the intended work, they are advised to contact the Pasco County Building Inspection Division —Licensing Section at 727-847- 8009. Furthermore, if the owner has hired a contractor or contractors, he is advised to have the contractor(s) sign portions of the "contractor Block" of this application for which they will be responsible. If you, as the owner sign as the contractor, that may be an indication that he is not properly licensed and is not entitled to permitting privileges in Pasco County. TRANSPORTATION IMPACT/UTILITIES IMPACT AND RESOURCE RECOVERY FEES: The undersigned understands that Transportation Impact Fees and Recourse Recovery Fees may apply to the construction of new buildings, change of use in existing buildings, or expansion of existing buildings, as specified in Pasco County Ordinance number 89-07 and 90-07, as amended. The undersigned also understands, that such fees, as may be due, will be identified at the time of permitting. It is further understood that Transportation Impact Fees and Resource Recovery Fees must be paid prior to receiving a "certificate of occupancy" or final power release. If the project does not involve a certificate of occupancy or final power release, the fees must be paid prior to permit issuance. Furthermore, if Pasco County Water/Sewer Impact fees are due, they must be paid prior to permit issuance in accordance with applicable Pasco County ordinances. CONSTRUCTION LIEN LAW (Chapter 713, Florida Statutes, as amended): If valuation of work is $2,500.00 or more, I certify that 1, the applicant, have been provided with a copy of the "Florida Construction Lien Law —Homeowners Protection Guide" prepared by the Florida Department of Agriculture and Consumer Affairs. If the applicant is someone other than the "owner", I certify that I have obtained a copy of the above described document and promise in good faith to deliver it to the "owner" prior to commencement, CONTRACTOR'SIOWNER'S AFFIDAVIT: I certify that all the information in this application is accurate and that all work will be done in compliance with all applicable laws regulating construction, zoning and land development. Application is hereby made to obtain a permit to do work and installation as indicated. I certify that no work or installation has commenced prior to issuance of a permit and that all work will be performed to meet standards of all laws regulating construction, County and City codes, zoning regulations, and land development regulations in the jurisdiction. I also certify that I understand that the regulations of other government agencies may apply to the intended work, and that it is my responsibility to identify what actions I must take to be in compliance. Such agencies include but are not limited to: - Department of Environmental Protection -Cypress Bayheads, Wetland Areas and Environmentally Sensitive Lands, Water/Wastewater Treatment. - Southwest Florida Water Management District -Wells, Cypress Bayheads, Wetland Areas, Altering Watercourses, - Army Corps of Engineers -Seawalls, Docks, Navigable Waterways, - Department of Health & Rehabilitative Services/Environmental Health Unit -Wells, Wastewater Treatment, Septic Tanks. - US Environmental Protection Agency -Asbestos abatement, - Federal Aviation Authority -Runways, I understand that the following restrictions apply to the use of fill: - Use of fill is not allowed in Flood Zone W" unless expressly permitted. - If the fill material is to be used in Flood Zone "A", it is understood that a drainage plan addressing a "compensating volume" will be submitted at time of permitting which is prepared by a professional engineer licensed by the State of Florida, - If the fill material is to be used in Flood Zone "A" in connection with a permitted building using stem wall construction, I certify that fill will be used only to fill the area within the stem wall. - If fill material is to be used in any area, I certify that use of such fill will not adversely affect adjacent properties. If use of fill is found to adversely affect adjacent properties, the owner may be cited for violating the conditions of the building permit issued under the attached permit application, for lots less than one (1) acre which are elevated by fill, an engineered drainage plan is required, If I am the AGENT FOR THE OWNER, I promise in good faith to inform the owner of the permitting conditions set forth in this affidavit prior to commencing construction. I understand that a separate permit may be required for electrical work, plumbing, signs, wells, pools, air conditioning, gas, or other installations not specifically included in the application. A permit issued shall be construed to be a license to proceed with the work and not as authority to violate, cancel, alter, or set aside any provisions of the technical codes, nor shall issuance of a permit prevent the Building Official from thereafter requiring a correction of errors in plans, construction or violations of any codes. Every permit issued shall become invalid unless the work authorized by such permit is commenced within six months of pen -nit issuance, or if work authorized by the permit is suspended or abandoned for a period of six (6) months after the time the work is commenced. An extension may be requested, in writing, from the Building Official for a period not to exceed ninety (90) days and will demonstrate justifiable cause for the extension. If work ceases for ninety (90) consecutive days, the job is considered abandoned. WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TOOT IN FINANCING, CONSULT FLORIDA JURAT (F.S. 11 , 3) OWNER OR AGEt?4��,e_ CONTRACTOR_`k-'4vV_4V'%VN U)(;\1i Sub4scri ?e,and sw to (or affirmed) before me ihhiis�' Su sari e an sworn to ra irmedTb_efNq..­f1S__ 'r b by Z' W4h' is�/ , awpersonall known tome orhas/have oduced W die r ersonall,k own or has/have oduced R _'_ as identification, as identification. Notary Public �4 m 0 mission No, 7t Commission No. Ap, P vD dz� V1 a— Vake of Notary typed, prihted or stamped ame of Notary typed, print d or stamped .0y Poe, BRENDAPROBAWO ORENDAPROBASCO Cqmrrilw4on # HH 180622 C9mmW"#NH`IW22 Exphu 111,10"inber 29,2025 A E ''�OF Fxphs Nmember 29,2026 8anWTWuk**N*Wy8**N 8QndWDmk*dNoWySW*" ��*, 5W INSTR#2023092857OR BK10823 PG1621 Page 1 of 1 0512412023 10:10 AM Root 2586408 Rec: I OL00 DS: 0.00 IT: 0.00 Nikki Alvarez-Sowles, Esq., Pasco County Clerk & Comptroller Permit Na. Parcel IONo IR State of foyl—d—ge NOTICE OF COMM , E , of NCEMEN� THE UNDERSIGNED hereby gives notice that improvement will be made to certain real property, and in accordance win Chapter 713, Florida Statutes, the following information is provided in this Notice of Commencement: I. Description of Property! Parcel Identification No, 6a 00 - 0 t Cr Street Address: 2. General Description of Ireprovern onif Disinter information or Lessee information if Inc Lessee contracted for the improvement N Interest in Properhn J/ 4v/\..o 4" Name of Fee Simple Titleholder: fit different from Owner listed above) N Contractors Telephone No.: -k-P-T- 5, surety, Address City state Amount of Bond: $ Telephone, No.: Lender: AJ Name Address City State Lender's Telephone No,: 7. Previous within the State of Floods designated by the owner upon whom notices or other dotormants, may he. served as provided by Name Address City State Telephone Number of Designated Person: a. In addition to himself, the owner designates of -- to receive a copy or the Lienor's Notice as provided in Section 713,13(i)(b), Florida Statutes. Telephone Number of Person or Entity Designated by Owner: 9. Expiration date of Notice of Commencement (the expiration data may not he before the completion of construction and final payment to the contractor, but will be one year from the date of recording unless different date IF specified): WARNING To OWNER. ANY PAYMENTS MADE BY THE OWNER AFTER THE EXPIRATION OF THE NOTICE OF COMMENCEMENT ARE CONSIDERED IMPROPER PAYMENTS UNDER CHAPTER 713, PART I, SECTION 713,113, FLORIDA STATUTES, AND CAN RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY, A NOTICE OF COMMENCEMENT MUST BE RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST INSPECTION, IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE COMMENCING WORK OR RECORDING YOUR NOTtQE OF WMMENCEMEN-. Under penalty of perjury, I declare that I have read the foregoing nortme of commencement and that the facts stated therein are true to the, bear of my knowledge and belief, STATE OF PLORIDA COUNTY OF PASCO gntiure of ?wner or Legs". or Ovencr'f, o essee' on2ml Ofter/Diref,,Ior/Par',ner/Manager Signatory's TitielOffice The foregoing instrument was acknowledged before me this'" day *9., as (type of immunity, a, area, Me ey in fact) for (name of y on of whom inst cot was executed). Personally Known E] OR Produced Identification Notary Signature Typo of Identification Produced Name iPflot)._ C"Whift I HN IN522 E*k" NM16W 29,2025, Total Wattage: 10,4*01V DC Roof Type: Composition Shingle Wind Load: 21 to 27 Deg Fastener Type: Use 5/16" Dia 4" Lags Sheet Index S-1 Cover Sheet / Site Plan S-2 Detail E-I One - Line E-2 Electrical Code S-IA Mounting Plan General Notes: -Enphase IQ8A-72-2-US Micro Inverters are located on roof behind each module. -First responder access maintained and from adjacent roof. -Wire run from array to connection is 40 feet. : z-11 Legend: / IFirst responder access F­7 GrOUnd Access Chimney Utility Meter Satellite Vent Pipe PV Disconnect X Ul System meets the requirements of NFPA 70th Edition, Chapter I - 11, 12 (2018 Edition) Install will be done to Manufacturer Spec Meets All Editions of Florida Fire Prevention Code 2020 7th Edition Meets all requirements of 2018 Editions of NFPA- I and NFPA- 10 1 �2U' X—cce—ssPat5R� 7/ Represents all Fire Clearance I st Responder Access including Alternative methods minimum of 36" unobstructed as per Section R324 of the 2020 IRC Meets the requirements of the following- (2020 FL Residential Code & FBC, 7th Edition (2020 International Residential Code) - 2nd Printing modified by the FL Building Standards, 2020 Florida Building Energy Conservation Code 7th edition, City of Zephyrhills Code, 2017 National Electric Code.) COTTY RESIDENCE 5316 SATSUMA DRIVE ZEPHYRHILLS, FL 33542 -COGEN Disconnect Located adjacent to Utility meter Utility Meter Godwin Engineering and, Design, LLC 8378 Foxtail Loop Pensacola, FL 32526 D. Chad Godwin, PE Chada dwineng.com Date: 5/25/2023 Drawn by: MM Revisedby: ....................................... Rev Date: C. 0 0 9 81 0. 1 60 0 ,rAr OF 0 P to, Zo G; COMDaSS for Aerial Roof Type: Roof pitch & Overhang Mount Type Fastener: Ironridge XR-100 Composition Shingle 6/12; 12" Overhang Quick Mount Flashing - — ----- -- 5/16" x 4" SS Lag bolts into Roof Rafters 2"x4" Wood Trusses @ 24" O.C. All penetrations are seated and flashed Rafter a s Zone I Zone 2e Zane 2n Zane 2r Zone 3e Zane 3r Fr ed _ 4 " 4 to 241' 24$t 24°° 24Rr Non -Exposed 72" 72°' 72"` 7211 72" 489 Exposureate cry as per 71 Inverter Type: (26)Enphase IQ8A-72-2-US pV panel: (26) Q.PEAK DUO BLK ML-C10+ 400 Racking: Iron Ridge XR-100 Total Wattage: 10,400W DC Roof Type: Composition Shingle Wind Load: 21 to 27 Deg Fastener Type: Use 5/16" Dia 4" Lags HEX HEAD BOLT 3/ --- a6 __ _� FLANGE E NUT COTTY RESIDENCE 5316 SATSUMA DRIVE ZEPHYRHILLS, 33542 Install will be done to Manufacturer Spec 6 Godwin Engineering and �� --��� ei ;- Design, LLC P4 !d 8 8378 Foxtail Loop Pensacola FL 32526 m e D. Chad Godwin, PE Chad a godwineng.corn STAT OF �'�'�0t'D'-P�°������� ONAL CI. Drawn by:111MM ►. Rev Date.-,.- 12-2 Romex can be used for interior building and attic runs only. Do not use romex in conduit or outdoor environments. #10 AWG'FHWN for Home runs (I) Line I (1) Line 2 Per Circuit (I)EGC Inside (a) least 3/4" Conduit Nlad on site) --------- Enphase Output Ckt Per String To Overcurrent Protection Device I AC Max Output Current 1 ��.�y_� .0 _ AC Max Output Current 1.25 /a — p * ° , 1 Overcurrent Protection A 20 No. of Current Carrying Cond - _ <4 _.— Conductor Gauge (AWG) 10 Enphase Total Output Ckt AC Max Output Current -- -3T7 _ AC Max Output Current 125% 47,1 j Overcurrent Protection (A) 60 No. of Current Carrying Cond <4 -- Conductor Gauge (AWG) Including the label below In ' of Emergency Call r P 1 i. NEMA 3R Junction Box BIack - L I Red - L2 Green - Ground Auer Combiner B To Line Side Tara C Enphase IQ Trunk Cable Q-12-240 #12AWG THHN-THWN-2 UL, 9703 Grounding Conductor u1I tioi be protected ! i #8 Awg or to be unprotected ,# Awg s :Ill rMM" UTPUTCURRENT: 37.7A ERATING VOLTAGE: 240VA0 - -- Photovoltaics: (26) Q.PEAK DITCH BLK ML-G 10+ 400 Inverters: (26) Enphase IQ8A-72-2-US Micro Inverters Circuits: (2) circuits of (9) Modules (1) circuit of (8) Modules Maximum Inverters Per 20A Circuit (11) Main Service Panel 150A Main Enphase Combiner Box Manual Lockable Disconnect#x-IQ-AMI-24o - 60A Service Rated / Fused Disconnect Neutral to Ground Bond - I .AC Disconnect aon o— - - 5€)A Fuse --q I0A/15A - I 20A� Located Adjacent Utility o- to Meter 20A -- Envoy -IQ Momton I conduit (in) Ll L2-,N (A.g) FG1.11d (Asag) F OCPD 0.75 6 850 0.75 6 N/A 50 Dote: -All wiring to meet the 2017 NEC and Florida electric codes. 60A Disconnect -Type of conduit to be determined on site by contractor. Meets 11,12.2.1.5 1 Install will be done to Manufacturer GTEC NOTES - t;ngrounded system per 69 AI(A)(4) 6EC must be installed per 250.64 - GEC must be continuous €rn-spliced or irreversibly spliced from inverter to existing service ground s} stent or continuous from the arrays to the existing service ground system. - GEC' must be min #8 AWG and installed in conduit - If GEE' is not in conduit, it must be 96 nun Disconnects will be Visible, lockable, adjacent to and within 5' of utility meter All 1,abels & Markings for photovoltaic system will be reflective and meet all requirements for NFPA I :11:12 Supply Side'rap In Compliance with NEC 705- I2(A) NEC LABEL NOTES:_ 1. THE WARNING SIGN(S) OR LABEL(S) SHALL. COMPLY VOTH NEC 110-21(B) 2. LABELS SHALL BE SUITABLE FOR THE ENVIRONMENT WHERE THEY ARE INSTALLED, 3. LABELS TO BE A MIN LETTER HEIGHT OF 3/8" AND PERMANENTLY AFFIXED. 4. LABELS SHALL ALSO COMPLY sMFi-t THE SPECF1C, REQUIREMENTS OF THE AUTHORITY HAV€NG JURISDICTION. Disconnect is in compliance 230.72 Supply side disconnect adjacent to Msp Line Side'lap will be done in Main Service Panel locates{ inside I louse COTTY RESIDENCE SATSUMA5316 s ZEPHYRHILLS, FL 1=11 ReferN2 C3 Conditioaps &infoiwitc(nlI and over current devices Enclosures. If the conditions are not nnet a tap box will need to he installed and revision coin tep ted. V0lltilt///� Godwin Engineering and �� e VX 1_�� Design, LLC 6a ®® �1 8378 Foxtail Loop Pensacola, FL 32526STJ TE OF D. Chad Godwin, PE�4 la � Chad c�godwineng.co Date: 5/25/2023 Drawn by: MM r ff— .I 'Rev Date: ► g, Inverter Type: Enphase IQ8A-72-2-t7S PV Panel: (26) QYEAK DUO BLK ML-G10+ 400 Total Wattage: 10,400W DIC System meets the grounding requirements of NEC 690,43 The Placard shall be permanently -A placard will be added with riveted.,., and shall be made of red,': instructions and locations to be weatherproof, hard plastic, with in compliance with 690, 12, engraved white block lettering, 690,56(B) and NEC 705.10 Rapid Shutdown Built in In compliance with NEC Per Code NEC 690,12 250�58, NEIC 690.8, NEC 250.24, NEC'250,24(1)) PV AC disconnect is Conductors have a min lockable in the open position arnpacityofWamperes per code NEC 705.22(7) Per Code NEC 230,79(D) Everything will be built to Code without all Specifics labeled on plan I System is in compliance with FFPC 1: 11 . 12 7th Edition. Inverter Output Ckt To Overcurrent protection Device with Copper Design Tempera ture(F) 947 Max Amb Temp Rangefn 97-95 3110,15(8)(2)(a) Temp Ratingof Conductors LC} 75'C - Current Carrying AC Max Output Current <4 38A 31(115ai)(3)(a) 6go%,8(AX3) AC Max Oulpat Current 1 125% 47A 0.8(8) Gvercurrent Protection(A) Amp TeMil Corrertion Factor 50A 0,94 310,15(B (2)(a) Raceway Fill adjustment Factor 1009. AN sa�a,(Awp,) Coad. Affiowabfe!mpacity(A) 6 65;t 310A5(g)(16) Cond Adjusted Ampadly(A) GIA 65A*1*0.94=61JA 'Ampacftyqheck I Per 690,8{8)(I) AmPacity Check 2 Per 690,8(8)(2p Pass Pass 37,7A*L25=50A<65A Pass 65A*0.94A'1=61.1A>37,7A Pass :All Exterior equipment is A minimum of Nema-R3 Rated -- - - - - - -- - ---------------- - - ----- In compliance with 230,71 Markings shall be placed on all DC Conduits-, DC Combiners,: All Interactive Systern(S) Points of interconnection Raceways, Enclosures, Junction Boxes, and Cable Assemblies:' with other sources shall be marked at an accesible Combiner box in compliance at every 10', turns, and above and below penetrations in location at the disconnecting means as a power Per Code NEC 705.12 compliance with NFPA source and with the rated ac output current and the i i 3* 20A < 125A Smoke Alarms per F.S. 553.883 nominal operating AC voltage. Per NEC 69034 *No other loads to be added Disconnect means shall be provided for all disconnecting all ungrounded conductors that supply I or pass through the building or structure Per Code 2017 NEC Section 225.31 & Section 225.32 E04. Construction documents specify PV system circuits I Over Current Protection Device is "Next size up" -All Electrical Service Equipment shall be located at or above installed on or in buildings include a rapid shutdown function Based on Inverter Maximum Continuous Output BFE+ l'or 8,00'NAVI) that controls specific conductors in accordance with NEC :Current article 690.12. Rating 2017 NEC 240,4(B) E05. These construction documents specify that a label is -All new equipment Labels will be placed provided with the method to initiate rapid shut down per located adjacent to in the correct location j 1 -Markings Shall Be reflective, Weather Resistant and suitable fin the envixonment, 690.12(4). Per Code NEC 690.56(B), Meter on exterior wall -Markings shall be red wilh vhae lettering with niumn n Capital Letters 690,56(C)& 690.53 E06. Construction drawings specify buildings or structures with both utility service and a PV system, complying with NEC article 690.12 shall have a permanent plaque or directory including the following wording: "PHOTO VOLTAIC SYSTEM EQUIPPED WITH RAPID SHUTDOWN"as per NEC article 690.56 (C). E07, Construction documents specify PV power circuit labels shall appear on every section of the wiring system that is separated by enclosures, walls, partitions, ceilings, or floors. E08. Construction documents specify all warning sign(s) or label(s) shall comply with NEC article 110.21 (B). Label warnings shall adequately warn of the hazard. Labels shall be permanently affixed to the equipment, and Labels required shall be suitable for the environment. Note: Include required label for metallic raceways and conduits to -Subject PV Systems has been designed sheet E-1 per NEC article 690,31 (G)(3). ti-i meet the re ";rmentc of the NEC Ifill NFPA 111 12 2, 1, 1, 1.1 and 11, 112,13 1 SOLAR PV 318 IN MIN. TEXT 1 1-- r ICE METER RVED BY A C SYSTEM 705A2(B)(3) POWER SOURCE i OUTPUT CONNECTION DO NOT RELOCATE THIS OVERCURRENT DEVICE 705.12(B)(2)(3)(b) TURN RAPID SHUTDOWN SWITCH TJ, 3/16 IN MIN. TEXT THE "OFF" POSITION TO, SHUT DOWN PV SYSTEM AND REDUCE IP T LTAIC P ER SOU SHOCK HAZARD IN THE ARRAY. NEC 690.31 (G)(3) Figure 690.56(C)(1)(a) Label for PV Systems that Shut down the array and the conductors leaving the array Add required label to sheet E-1 per NEC article 705.10, i i and those set forth by the Florida Solar Include required label to sheet E-1 per NEC article 705.12(B) Energy Center Certification, Including Photovoltaic AC disconnect shall be capable of being locked Maximum Number of Module String, i sWM in the open position per NEC article 705.22(6). Maximum number of modules per string, ELEQTRIQ�H CK HA ARD T. �"r DO NOT TOUCH Photovoltaic AC Overcurrent protection shall be located Maximum Output, Module Manufacturer and TERNMALS5 ON 8� sr 7 k"'A Within 10 feet of the point where conductors are connected to AND LOAD; SUES V, model number, inverter manufacturer and model N 7HL OPEN POG'TrfN the service per NEC 70531, number, as applicable. NEC 690.13 NEC 705.10 A permanent plaque or directory, denoting the location of all electric power source disconnecting means on or in the premises, shall be installed at each service equipment location and at the location(s) of the system disconnect(s) for all electric power production sources capable i of being interconnected. One sign required for each PV system, Plans Satisfy NEC 250.94 & NEC250.53(A)(2) Install will be done to Manufacturer S Apply to Main Disconnect In Case of Emergency Call Voltage Pro Solar & Electric Inc Pe anent sticker added to disconnect =�, W COTTY RESIDENCE 5316 SATSUMA DRIVE ZEPHYRHILLS, FL 33542 \sswl I I 11/1//// eke C. Go Godwin Engineering and 0 Design, LLC c, 8378 Foxtail Loop 1360 Pensacola, FL 32526 D. Chad Godwin, PE 0 TATE F 14U "�'40RIiDl" Chad(i�godwinengxom `0 Rev Date: Page: I I flxl Ti Inverter Type: Enphase IQ8A-72-2-US PV Panel: (26) QTEAK DUO BLK ML-G 10+ 400 Total Wattage: 10,40OW DC 14' 18 10 -Splice Bar 45 Quick Mount Flashings 60 Iron Ridge UFO's 16 Iron Ridge Sleeves/End Caps 2 Roof Top Combiner 4 Iron Ridge Ground Lugs 26 Q.PEAK DUO BLK ML-G 10+ 400 26 Enphase IQ8A-72-2-US I 60A Fused Disconnect 2 50A Fuses 3 20A 2P Breakers I Enphase Combiner Box mom I 7�1 '"� 7 " 4 " 2 H; 4 jq�f Max Cantilever = Max span * (2) 5 W Inverter Typ PV Panel: In v V e P rt a er e T y p g_ Rackin�4: Roof Type Wind Load: y Fastener Ty (26)Enphase IQ8A-72-2-US (26) Q.PEAK DUO BLK ML-GIO+ 400 Iron Ridge XR- 100 10,40OW DC Composition Shingle 21 to 27 Deg Use 5/16" Dia 4" Lags N R-2 4 Modules (8) Pitch: 27' Azimuth: 89' R-I # Modules (18) Pitch: 27' Azimuth: 269' COTTY RESIDENCE 5316 SATSUMA DRIVE ZEPHYRHILLS, FL 33542 I iA Id Exposed Non -Exposed Spacing Spacing Plans satisfy zones FBC-1 510.7.1 Install will be done to Manufacturer Spec Godwin Engineering and C. 0 X� - ---C --- 0 " X Design, LLC ' 8378 Foxtail Loop .8660 Pensacola, FL 32526 M TE D. Chad Godwin, PE 0 OF /4 41 Chad godwineng.com AL Date: 5/25/2023 N THE IDEAL SOLUTION FOR: 6 Rooftoparrays on 2) residential buildings 11 THE MOST THOROUGH TESTINGFIROGRAMME INTHE INDUSTRY Q CELLS is the first solar module manufacturer to pass the most comprehen- sive quality programme in the industry: The new "Quality Controlled PV" of the independent certification institute TOV Rheinland. INNOVATIVE ALL-WEJOHER TECHNOLOGY Optimal yields, whatever the weather with excellent low -light and temperature behavior. ENDURING HIGH PERFORMANCE Long-term yield security with Anti LID Technology, Anti PID Technology', Hot -Spot Protect and Traceable Quality Tra QTV. EXTREME WEATHER RATING High-tech aluminum alloy frame, certified for 7177 high snow (5400 Pa) and wind loads (4000 Pa), J A RELIABLE INVESTMENT 1EA ?� Inclusive 25-year product warranty and 25-year c linear performance warranty2. APT test conditions according to'EC/ TS 62804-1:2015, method A (-1500V, 96rtt See data Sheet an rear for further information. CEIIS At least 98%of nominal power during first year, Thereafter max. 0,5% degradation per year, At least 93,5 % of nominal Dower up to 10 years, At c least 86 % of nominal power up to 25 years. w r All data within measurement toleranc- as. Full warranties in accordance with the warranty terms of the 0 CELLS sales Organisation of your respective country, Typical nnortude performance under low irradiance conditions in comparison to STC conditions 125*C, J000W/,y) TEMPERATURE COEFFICIENTS lue'du rr f cisn't of r, a [%/Kl +0.04 'enn"urtrat"re Ccrcf crent, of V4. /K] -0.27 Zarrfper-Aure L'oefficiam vf P_, y [%/Kl -0,34 Nk,,rrrd­e, O'Pe,nring n;nocenlf, ne Nba07 ['Fl 109±5A(43t3'C) PROPERTIES FOR SYSTEM DESIGN r mum tSqe V", tv] 1000([EC)/1-000(UL) PV rnoduo� -_assificabon Class 11 Sy�it�­­­ vo� ... . ....... ..... `AaXi`r,',U�Y� SoKes F�usa R q, [A DC J 20 Fera ReMrs,,g bused on, Vh S 1 617", 0 TYPE 2 Pr Design Lor�dPut-,h, �Pf,�P [lbs/ft'l 75(3600Pa)/65(2660Pa) -40 L=_ up to , i85°F sA a x, To n I L o a d s h / P [lbs/fp] 113 (5400 Pa)/ 84 (4000 Pa) - 'Onfiry s Du v (-40'C,,jp to �85'C) 'See installation Manual - --- - ------------ QUALIlFICATiONS AND CERTIFiCATES PACKAGING INFORMATION ------------- UL 61.730, CE camollart, F1 ia� h Qusfity crr"'fl.,d Pv, T 'V ,n,,,,,.LLf IPC 61215�2016IEC 11130�2( C E - U Stwf_on9,893215coCn vanes 76.4in 43.3in 48,0r, 1656lbs 24 24 32 CPVCwhL_t,_"'g-9 c _us giug 1940mnn _1�00rnm 1220mm 751 g pallets pallent modules IL all. Note: installation instructions must be followed, See the installation and operating manual or contact our technical service department for further information on approved installation slid use of this product. Hanvwha OCELLS America Inc. 400 Spectrum Center Drive, Suite 1400, Irvine, CA 92618, USA I TEL ' 949 748 59 96 1 EVAyL rrqury@us,q-cefls con, i WEP wwwol-ceiiscs ENPHASE 10� 1Q8M and 1Q8A Microinverters I 10T1*1 K F "M Our newest 108 AIA power to AC power efficiently. The brain of the semiconductor -based microinverter is our proprietary application -specific integrated circuit (ASIC) which enables the microixmerter t* *,#eree iA grii-tivi, it #K-Vri4 m#,8es. T��is cl�4 is *Yilt iin aivari re-ei 55nm technology with high speed digital logic and has super -fast response times to _2Y urq.":i�W9 k�ts osi� W-R*wy S��,g 4f-�"cTmL energy systems. Part of the Enphase Energy System, 108 Series Microinverters, integrate with the Enphase 10 Battery, Enphase 10 Gateway, and the Enphase App monitoring and analysis software. Connect PV modules quickly and easily to 108 Series Microinverters using the included O-DCC-2 adapter cable with plug-n-play MC4 connectors. IQ8 Series Microinverters redefine reliability standards with more than one million cumulative hours of power -on testing, enabling an industry -leading limited warranty of up to 25 years. 108 Series Microinverters are UL Listed as PV Rapid Shut Down Equipment and conform with various regulations, when installed according to manufacturer's instructions. @ 2022 Enphase Energy. All rights reserved. Enphase, the Enphase logo, IQ8 Microinverters, and other names are trademarks of Enphase Energy, Inc. Data subject to change. IQ8MA-DS-0003-01-EN-US-2022-03-17 Easy to install plug-n-play connectors Power Line Communication (PLC) between components wigh'i �-2� 0252MR-17 W . Now High productivity and reliability Produce power even when the grid is down* More than one million cumulative hours of testing Class 11 double -insulated enclosure Optimized for the latest high- powered PV modules Complies with the latest advanced grid support** Remote automatic updates for the latest grid requirements Configurable to support a wide range of grid profiles Meets CA Rule 21 (UL 1741-SA) requirements Only when installed with IQ System Controller 2, meets UL 1741. IQ8M and 108A supports split phase, 240V installations only. Commonly used module pairings' w 260-460 295-500 Module compatibility 60-cell/120 half -cell, 66-cell/132 half -cell and 72-cell/144 half -cell MPPT voltage range V 33-45 36-45 Operating range V 25-58 Min/max start voltage V 30/58 Max input DO voltage v 60 Max DO current2 [module Isc] A 15 Overvoltage class DO port 11 Do port backfeed current mA 0 PV array configuration Ixl Ungrounded array; No additional DC side protection required; AC side protection requires max 20A per branch circuit Peak output power VA 330 366 Max continuous output power VA 325 349 Nominal (L-L) voltage/range3 V 240 / 211- 264 Max continuous output current A 1Z5 1.45 Nominal frequency Hz 60 Extended frequency range Hz 50-68 AC short circuit fault current over 3 cycles Arms 2 Max units per 20 A (L-L) branch circuit4 11 Total harmonic distortion .5% Overvoltage class AC port III AC port backfeed current mA 30 Power factor setting 1.0 Grid -tied power factor (adjustable) 0.85 leading - 0.85 lagging Peak efficiency % 97.6 97.6 CEC weighted efficiency % 97 97.5 Night-time power consumption mw 60 Ambient temperature range -400C to +60°C (-40OF to +140°F) Relative humidity range 4% to 100% (condensing) DO Connector type MC4 Dimensions (HxWxD) 212 mm (8.3") x 175 mm (6.9") x 30.2 mm (1,2") Weight 1.08 kg (2.38 lbs) Cooling Natural convection - no fans Approved for wet locations Yes Pollution degree PD3 air 17 I NMI Certifications This product is UL Listed as PV Rapid Shut Down Equipment and conforms with NEC 2014, NEC 2017, and NEC 2020 section 690.12 and C22.1-2018 Rule 64-218 Rapid Shutdown of PV Systems, for AC and DO conductors, when installed according to manufacturer's instructions. (1) No enforced DC/AC ratio, See the compatibility calculator at https://Iink.enphase.com/module-compatibility (2) Maximum continuous input DO current is 10.6A (3) Nominal voltage range can be extended beyond nominal if required by the utility. (4) Limits may vary. Refer to local requirements to define the number of microinverters per branch in your area. 108MA-DS-0003-01-EN-US-2022-03-17 t...a.,., ve,do... C V v -- v kw vim. yl a» zr g A c v , is � � :L ,. .,U "mom f -1- X-IQ-AMl-240-4 LISWD To learn more about Enphase offerings, visit en h se.co The rt„as 'o f finer 4/ 1-3 with Enphase IQ Gateway and Integrated LTE-M I cell r-noderrl (included only with IQ Combiner 4C;) consolidates interconnection equipment into a single enclosure and streamlines !Q m croinverters and storage installations by providing a consistent, pre -wired solution for residential applications. It offers up to four 1 pole input circuits and Eaton BR series busbar assembly. Includes IQ Gateway for communication and control Includes Enphase Mobile Connect cellular modern (CELLMODEM-Ml-06-SP-05), included only with IQ Combiner as Includes solar shield to match Enphase IQ Battery aesthetics and deflect heat Flexible networking supports Wi-Fi, Ethernet, or cellular Optional AC receptacle available for PLC bridge Provides production metering and consuroption monitoring Centered mounting brackets support single stud mounting Supports bottorll, back and side Conduct entry Up to four 2-pole branch circuits for 240 VAC plug-in breakers (not included) 80A total PC or storage branch circuits Durable NRTL certifies! NEMA type 3R enclosure Five-year limited warranty Two years labor reimbursernent program coverage included for both the IQ Combiner SKU`s UL listed W u wr 4ENPHASE Enphase IQ Combiner / MODEL NUMBER IQ Combiner 4 (X lQ AM? 240-4) IQ Combiner with Enphase IQ Gateway printed circuit hoard for integrated revenue grade PV production mstering (ANSI C12 20 +/- 0,5%) and consurnpt€on i canitoring (+/- 2.51/). Includes a Silver solar shield to match the IQ Battery system and IQ System Controller 2 and to defect heat. IQ Ccunbiner 4C (X-{Q-AM1-240-4C) IQ Combiner 4C with Enphase IQ Gateway printed circuit board for integrated revenue grade PV production metering (ANSI C12.20 +/-o.5i) and consumption monitoring (+/-2,5%). includes Enphase Mobile Connect cellular modern (CELLMODEM-M1-06-SP-05), a plug -and -pay industrialgrade cell modem for systems up to 60 microinverters. (Available In the US, Cariada, Mexico, Puerto Rico, and the US Virgin islands, where there is adequate cellular service in the installation area) includes a silver sonar shield to rnatch the IQ Battery and IQ System Controller and to deflect heat. ACCESSORIES AND REPLACEMENT PARTS (not included, order separately) Ensemble Communications Kit Includes COMMS-KIT-01 and CELLMODEM M1-06-SP 05 with 5-year Sprint data plan for CGMMS-CEL LMODEM-M7-06 Ensemble sites CELL MODEM-Mi-06-SP-G5 4G based LTE-MI cellular modern with 5-year Sprint data plan CELLMODEM-M1-06-Al-05 4G based LTE-MI cellular modem with 5-year AT&T data plan Circuit Breakers Supports Eaton BR210, BR215, 3R220, BR230, BR240, BR250, and BR260 circuit breakers - BRK-10A-2-240V Circuit breaker, 2 pole, 10A, Eaton BR210 BRK-15A-2-240V Circuit breaker, 2 pole, 15A, Eaton BR215 BRK-20A-2P-240V Circuit breaker, 2 pole, 20A, Eaton BR220 BRK-15A-2P-240V-B Circuit breaker, 2 pole, 15A, Eaton BR2158 with hold down kit support BRK-20A-2P-240V-B Circuit breaker, 2 pole, 20A, Eaton BR220B with hold down kit support EPLC-01 power line carrier (communication bridge hair), quantity- one pair XA-SO[-ARSHIELD-ES Replacement solar shield for IQ Combiner 4/4C XA-PLUG120-3 - Accessory receptacle for Power Line Carrier in 9Q Combiner 4/4C (required for EP1 C-01) XA-ENV-PCBA-3 Replacement IQ Gateway printed circuit board (PCB) for Combiner 4/4C X-IQ-NA-HD-125A - Hold down kit for Eaton circuit breaker with screws. ELECTRICAL SPECIFICATIONS Rating continuous duty System voltage 120/240 VAC, 60 Hz Eaton BR series busbar rating 125 A Max. continuous current rating 65 A Max, continuous current rating (input from PVlstoragd) 64 A Max. fuse/circuit rating (output) 90 A Branch circuits (solar and/or storage) Up to four 2-pole Eaton BR series Distributed Generation (DG) breakers only (not included)' Max total branch circuit breaker rating (input) 80A of distributed generation / 95A. with tQ Gateway breaker included Production metering CT 200 A solid core pre -installed and wired to IQ Gateway Consumption monitoring CT (CT-200-SPLIT) A pair of 200 A split Core current transformers MECHANICAL DATA �_„-, .... Dimensions (WxHxD) _,,, ,.. .., ..,.. .. _._..._.... _ .-. .... __ ...............,.,. ._,......, _.__ .. ._........ _...... 37 ., x 49.5 x 16.8 pro (14 75' x 19 5' x 6.63'). Height is 21 06° (53.5 cm) with mounting brackets. Weight T5 kg (16.5Ibs) Ambient temperature range -401 C to +461 C (-400 to 1151 F) Cooling Natural convection, plus heat shield Enclosure environmental rating Outdoor, NRTL-certified, NEdA type 3R, pciycarbonate construction Wire sizes 20 A to 50 A breaker inputs: 14 to 4 AWG copper conductors 60 A breaker branch input: 4 to 1/0 AWG copper conductors Maim lug combined Output: l0 to 2/0 AWG copper conductors Neutral and ground: 14 to 1/0 copper conductors Always follow local code requirements for conductor sizing. Altitude To 2000 meters (6,560 feet) INTER ET CONNECTION OPTIONS Integrated Wrl'i ...................... 80211 b/g/n Cellular CELLMODEM-M1-o6-SP-05, GELLMODEM MI-06-AT-05 (4G based LTE ,Mi cellular modem). Note that an Enphase Mobile Connect cellular modern is required for all Ensemble installations. Ethernet Optional, 802.3, Cat5E (or Cat 6) rJTP Ethernet cable (not included) COMPLIANCE Compliance, IQ Combiner UL 1741, CAN/CSA C22 2 No. 107. i, 47 CFR, Part 15, Class B, ICES 003 Production metering: ANSI C12.20 accuracy class 0.5 (Pr/ production) Consumption rnPtenrtgaccuracy class 2.5 Compliance, €Q Gateway UL 60601-1/CANCSA 22.2 No, 61010-1 To learn more about Enphase offerings, visit emphase.com 4 2021 Enphase Energy All rights reserved i`iiphase, the i npr use logo, IQ Cornhiner 4/4C, and other urrrws ; ,e t vderr arks of �np`ase:Eqv Inc. f7 -ujec -.. 2' 209 AM , & IRONRIDGE XR Rail Family Over their lifetime, solar panels experience countless extreme weather events. Not but the worst storms in 40 years. High winds capable of ripping panels from a roof, and snowfalls weighing enough to buckle a panel frame. Sloped roofs generate both vertical and lateral forces on mounting rails which can cause them to bend and twist. The curved shape of XR Rails is specially designed to increase strength in both directions while resisting the twisting. This unique feature ensures greater security during extreme weather and a longer system lifetime. Compatible with Flat & Pitched Roofs XR Rails are✓ IronRidge offers 35 —1,compatible with a range of tilt leg FlashFoot and ✓Vo ✓ options for flat U a N a other pitched roof 'M W �i E 4§2N ✓roof mounting � �jA 1-22 attachments. MEN" applications, XR10 XR 10 is a sleek, low -profile mounting rail, designed for regions with light or 6'spanning capability Moderate load capability Clear & black anodized finish Internal splices available 101 spanning capability Heavy load capability Clear & black anodized finish Internal splices available ........... . . . . . . . ........ XR1000 XR 1000 is a heavyweight among solar mounting rails. It's built to handle extreme climates and spans up to 12 feet for commercial applications. 12'spanning capability Extreme load capability Clear anodized finish Internal splices available The table below was prepared in compliance with applicable engineering codes and Standards.* Values are based on the following criteria: ASCE 7-16, Gable Roof Flush Mount, Roof Zones 1 & 2e, Exposure B, Roof Slope of 8 to 20 degrees and Mean Building Height of 30 ft. Visit lronRidge.com for detailed certification letters. 'Table Is meant to be a cmnpNfled span chart for conveying general rpffl capabiflfle. Use approved ce-fification letters 'or actwal design guidance. 8378 Foxtail Loop, Pensacola, FL 32526 1(850)712-4219 1 c1hiid �i,)godwiiienqconi _C June 2, 2023 To: Zephyrhills Building Department 5335 8th St. Zephyrhills, FL 33542 Subject: Cotty - Residential PV Roof Mount Installation 5316 Satsuma Drive Zephyrhills, FL 33542 To whom it may concern, This letter is regarding the proposed installation of a rooftop -mounted Solar PV system on the existing residential structure at the subject address. I have reviewed the attachment plan and have determined that the rooftop -mounted PV system is in compliance with the applicable sections of the following Codes as amended and adopted by the jurisdiction when installed in accordance with the manufacturer's installation instructions: 2020 Florida Building Code 7'1, Edition, FBC ASCE 7 Min. Design Loads for Buildings & Other Structures Design Criteria: Design Wind Speed(Vult) - 140 mph 3sec gust, Exposure Category - C, Risk Category 11 The rooftop -mounted photovoltaic panel system has been designed in accordance with FRG R324.4. When roof penetrations are necessary, they shall be flashed and sealed in accordance with the manufacture's installation instructions, R905.17.3. The PV system consist of the modules, railing, and connection hardware. Refer to the specific roof type calculation pages for PV dead loads. The portions of the existing structure covered with solar panels will be adequate for supporting the roof loads per 11324ALL The securement method of the the PV system is to be mounted parallel to the structure with the site specific railing and attachments according to the designed plans. The site specific wind load calculations for the module and their supports are attached with this document. Fasteners shall be installed to the designated roof member with the proper torque from the manufactures installation instructions. The design wind pressures for rooftop solar panels located on enclosed or partially enclosed buildings of all heights, with panels parallel to the roof surface with a tolerance of 2' and with a max height above the roof surface, h2, not exceeding 10 in. A min gap of 0,25 in shall be provided between all panels with the spacing of gaps between panels not exceeding 6,7 ft. in addition the array shall be located at least 2h2 from the roof edge, a gable ridge, or a hip ridge. It is the contractors responsibility to review all drawings for accuracy and notify the FOR of any discrepanices prior to beginning construction. To the best of my knowledge, the plans and specifications comply with the minimum requirements of the latest Florida Building code. Please see attached documents and contact me should you have any questions. Sincerely, D. Chad Godwin, PE 81360 Exp,02/28/2025 Page 1 GODWIN ENGINEERING AND DESIGN, LLC 8378 Foxtail Loop, Pensacola, `I, 32526 1(850)712-4219 1 etoo Jtruiture cretatts La RLSIUSarful L91211=10115 anger - n4-mz aa- Roof Angle 2V to 27- Roof Type Gable The securement method of the PV system is to be mounted parallel to the Asphalt Shingle Roof Covering AAs halt Shingle roof with the IR-100 railing and QM L-Mount flashings/attachments. The mounts should Mean Roof Height 15ft be staggered, where possible, to allow distribution of the design loads evenly to the 7- structure. The mounts shall be installed with (1) 5/16" x 4" Lag Screw, L-mount SG 0A2, to Rafter Spacing 4unCC Rafter Rafter/Truss Size M Wind Load Pararriaters Wind Speed (asd) 108 mph FRC R301.2.1.3 Basic Wind mph cup' 0 40 '4 21,14 Effective Wind Area B"', -r D C F C ft2 26.20 Exposure Cat. 3�'C, -r D -7-85 Wind Directionality go '1000 ft Table 26.6-1 Elevation <1000 ft Tfft, 1.00 Topographic factor Kc 360 in 26.8 or 26.8.2 bldg. least hori. dim ftyp.) 360 in Ground Elevation Factor Ko 1.00 Table 26.9-1 Roof Heigh, 15.00 Velocity Exposure Coefficient K, Table 26.10-1 Exposed Module Definition Array Edge Factor YE _085 1.50 Exposed 29.4A Exposed factor = 1.5 for uplift loads on panels that are Array Edge Factor Ye Solar Panel Equalization Factor Non. Exp 29AA exposed and within a distance 1.5(L,) from the end of Fig, 29.4-8 a row at an exposed edge of the array. Modules are condidered Exposed if d, to the roof edge > 0.5h and 1.00 0.67 - --21.75 Velocity Pressure qh pSf r=0.00256 K,K,,K,,K,V' on, of the following applies: Added Safety Factor 1.1 Allowable Pullout per mount 602.0 lbs 1, d, to adjacent array > 4ft. 0.4h or 0.6h 700 ft 1W 0bnGab/HJp-0L4h 12, d2 to the next adjacent mod > aft, ��00 10% of least horizontal dim ft 10-A of least h- Dim 0, 0.4h, which-ar is smaller, but not less than either 4% of Least her. Roof Zone Set Back a - 3.00 ft 0, 3ft. (flat roof - 0,61r) 5 h2 in Not > 10imp-ol height above on 2h2 10 in `min distance array shall be from the roof edge, Gable Ridge, or hip ridge 0.25 in min gap between all panel, but not > 6.7ft c11 --- TOO it 1.6-tal distance orthogonal to panel edge d2 0.25 it tholi-nal distance from edge of one panel to the nearest edge in the next row 0.5h 7.50 fir PV Attachment - Results GC, - Uplif GCP - Dowi p = qh(GCP)(gE)(V,)Ul P q,,(GC,)(g,)(ya)U p = qh(GC,)(9,,)(v,)DOwi p = qh(GCp)(9,,)(v.)DOwi Point load (Portrait Rails Point load (Portrait Rails Point Load (landscape Rails Point Load (landscape Rails Max Span (Portrait Max Span (Portrait Max Span (landscape Max Span (landscape Cantilever (Portrait Cantilever (Portrait Cantilever (landscape 1 ?. 9, ?0 1. �r ----T1.5 --7-21 1.5--- 2-1 -1 -72 7 23 0.5 0.5 0.5 0.5 0.5 -30,0 -0.5 -30.0 -431 -43,1 -43.1 -47.5 -19.0 -19,0 -27.8 -27,8 -27.8 -30.7 16.0 16.0 16.0 1&0 16.0 16,0 -- T6.0 --- 16.0 - -76,0 - 6.0 7- - 16.0 ITO --7370 -531 -531 -531 -293 -352.2 -352�2 #0 #-308.3 513.9 -513.9 -513.9 -37&6 -3083 443.2 -443,2 -443,2 -48&2 81 8 -195.9 48 -195,9 48 -285.8 48 -285.8 48 -285,8 48 -315.8 24 72 72 72 72 72 48 72 72 74 7-a 74 72 19 72 19 72 19 72 19 72 19 72 10 29 29 1 29 29 29 19 29 29 1 29 29 29 29 L 29 29 1 29 29 29 29 --- bpans wirn 7V -Deod Load QTY of Modules (26 in Portrait, Module Area Rail, Clamps, Mounts Total Rail Length Module W_, Array Wmod, Micro/optimizer W_ PV Rail wpv'ai' Total Weight Wtct'I Total Area A, Dead Load DP, Neight/attachment Fastener Allowable Pullout 21.14 I 182 49 1261 104 182 1547 549.52 2.81 1 34.4 (-1L5/16"-g 4" Lag Screw, L-mount SG 0.4; Diameter S.G. Thread Embedment per If of Fastener 5/16 0.42 2.3125 I psf 29A-7 Exposed psf 29.4-7 Non-Exp. psf 29A-7 Exposed psf 29A-7 Non-Exp. in P A A, Exposed lb in A., Non-Exp. lb p A.ff Exposed lb p A A., Non-Exp. in Exposed in Non-Exp. in Exposed in Non-Exp. in Exposed in Span * 40% Non-Exp. in Exposed in Non-Exu. aerate anowacre capable pressure rating is exceemea. Q.Peok DUO ML-GIO+ Module Specifications 6 At QwA0LE F E C I . ft2 CLAMPING AREA -041s E 0 lb/ft PQRTRAJT RAh, a It Ifts ROOF ATTACFIME�NT 360 lbs lbs PV MODDIS "k- lbs END 9 F ROVY C S•re OF Ins 2 ft LANDSCAPE RAIL A* Z I "I DN I psf lbs A ft 6.16 3.43 0.79 25,59, 039 11.21 --- Ultimate Allowable( Ult /1.5) Load Rating - snow 113.4 75.6 Portrait in Load Rating - wind -84.0 -56.0 Pag 2 Load Rating - Snow 4 316 Landscape In, Load Rating- wind -50.4 -316 F R-1 Modules j Pitch: 27' Azimuth: 21 Wind Load: 21 to 27 Deg Fastener Type: Use 5/16" Dia 4" Lags KM=- S-I Cover Sheet / Site Plan S-2 Detail E-I One - Line E-2 Electrical Code S-IA Mounting Plan General Notes: -Enphase IQ8A-72-2-US Micro Inverters are located on roof behind each module. -First responder access maintained and from adjacent roof. -Wire run from array to connection is 40 feet. H M System meets the requirements of NFPA 70th Edition, Chapter 1: 11, 12 (2018 Edition) Install will be done to Manufacturer Spec Y Liegend 11-6" Meets All Editions of Florida Fire Prevention Code 2020 7th Edition I / 7 z 1, z 1 First responder access Meets all requirements of 2018 Editions of NFPA- I and NFPA- 10 1 GrOUnd Access Chimney 3 _A�ce�KP::atyv a- Utility Meter 0 Satellite Vent Pipe z�7z�T Represents all Fire Clearance I st Responder Access PV Disconnect including Alternative methods minimum of 36" unobstructed as per Section R324 of the 2020 IRC Meets the requirements of the following- (2020 FL Residential Code & FBC, 7th Edition (2020 International Residential Code) - 2nd Printing modified by the FL Building Standards, 2020 Florida Building Energy Conservation Code 7th edition, City of Zephyrhills Code, 2017 National Electric Code.) -COGEN DISCOMIect Located adjacent to Utility meter Utility Meter Layout Subject to Change Based on Site Conditions "MWIMPTM Design, LLC 41378 Foxtail Loop Pensacola, F1, 32526 D. Chad Godwin, PE .godwineng.com ate® 5/25/2023 I Drawn by: Mm Revised by: DMBJ 'tpass for Aerial Ironridge XR- 100 RI - R2 T Roof Type: Composition Shingle Roof Pitch & Overhang' L6/12; 12" Overhang Mount Type: Quick Mount Flashing Fastener: 5/16" x 4" SS Lag bolts into Roof Rafters Structure: 2"x4" Wood Trusses 24" O.C. Sealing/Flashing. __fMl penetrations are sealed and flashed Extra Notes: rafter moans Zane I Zone 2e Zon�Zone 2r 4 Zone 3e Zone 3r 0sedgy 48ft 48" 24 24"I 24" 24 .Ex Non -Ex, 72" 72" 721t 72" 72ra 4� Inverter Type: (26)Enphase IQ8A-72-2-US PV Panel: (26) Q.PEAK DUO BLIP ML-G 10+ 405 Racking: Iron Ridge XR- 100 Total Wattage: 10,530W DC Exposure Category - C Kooi--type- -- Cornposruun Shingte Wind Load: 21 to 27 Deg -Designed as per ASCE7-16 Fastener Type: Use 5/16" Dia 4" Lags Sofas Module 31,8-16 X '3/4 HEX HEAD BOLr 318-16 FLANGE KU T COTTY RESIDENCE 5316 SATSUMA DRIVE ZEPHYRHILLS, FL 33542 Install will be done to Manufacturer Spec C 0, Godwin Engineering and Design, LLC W360 8378 Foxtail Loop Pensacola, FL 32526 4'. pt S.T'A'.TrE OF D. Chad Godwin, PE 0&ad L 0 R Chad (4,godwineng.corn Date: 5/25/2023 Drawn by: MM Rev Date: 09/11/20,23 Page: 11 "XI 711 S2 Enphase 1Q Trunk Cable Q-12-240 #12AWG TH -TH -2 U, 9703 - ------ -- Grounding Conductor to be protected 1 #8 Awg or to be unprotected #6 Awg - 250.64(l3) 250.66 & 250.120(C) NEMA 3R — --- ----- --- Junction Box Black - L1 Roof Red - L2 ....._.._---------- Green - Ground 12-2 Romex can be used for interior building and attic runs only, Do not use romex in conduit or outdoor 4 10 AWG THWN for Horne runs E?HCTE/ELTAICTNC !-0Tr='r7c C DISCCIIGT 1' Per Circuit Inside cot least 3/4" Conduit (tbd on site) NOMINAL OPERATING VOLTAGE 240VAC Enphase Combiner Box #X-IQ-AM 1-240 Enphase Output Cki Per String �zoR — To Overcurrent Protection device � a.4n A AC Max Output Current AC Max Output Current 1.25/o6,3 ------- — -- Overcurrent Protection (A} No. of Current Carrying Cond <4-- _ — - o oA ---- EnvuL i y `� Monttar I- Conductor Gauge (AWG) _ ----Enphase 1t1--- - ---- -, Enphase Total Output Ckt - -- -._ Output Current AC Max ...----- 37.7 � AC Max Output Current 125% 47.1 Overcurrent Protection A — _ ( ) 6Qt,daant 1'r'i_ l t l z,l .___ rren No. of Current Carrying Cond After Combiner � B I 0,75 6 g Conductor --- Gauge (AWG) 6 its Line Side Tap C 75 6 N/A Including the label below In Case of EmergencyCall Voltagez i Electric Inc / *. Meets 11,12.2.1.5 Mote: -All wiring to meet the 2017 NEC and Florida electric codes. 60A Disconnect -Type of conduit to be determined on site by contractor, Install will be done to Manufacturer Photovoltaics: (26) Q.PEAK DUO PLK ML-G10+ 405 Inverters: (26) Enphase IQ8A-72-2-US Micro Inverters Circuits: (2) circuits of (9) Modules (I) circuit of Modules Maximum Inverters Per 20A Circuit (11) IM Main Service Panel 150A Main Supply Side Tap i Manual Lockable Disconnect j i f C _ 60A Service Rated 1 Fused Disconnect _ Neutral to Ground Band - �- AC Disconnect 50A Fuse j i Located Adjacent to Utility Meter 1 In Compliance with NEC 705.12(A) 0 GEC" Nt)TES - ungrounded system per 690.41(A)(4) - GEIC most be installed per 250.64 - GFC must be continuous un-spliced or irreversibly spliced from inverter to existing service ground system os continuous front the arrays to the, existing service ground system. - 6EC must be min #8 AWG and installed in conduit - If GEC, is not in conduit, it must be 46 ruin Disconnects will be Visible, lockable, adjacent to and within 5' of utility meter All Labels & Markings for photovoltaic system will be reflective and meet all requirements for NFPA I :11:12 NEC LABEL NOTE& 1. THE WARNING SIGN(S) OR LABEL(S) SHALL COMPLY VATH NEC 110.21(B) 2. LABELS SHALL BE SUITABLE FOR THE ENVIRONMENT WHERE THEY ARE INSTALLED. 3. LABELS TO BE A MIN LETTER HEIGHT OF 3/8" AND PERMANENTLY AFFIXED. 4. LABELS SHALL ALSO COMPLY WITH THE SPECIFIC REQUIREMENTS OF THE AUTHORITY HAVING JURISDICTION. Disconnect is in compliance 230.72 Supply side disconnect adjacent to Msp Line Side Tap will be done in Main Service Panel located inside House COTTY RESIDENCE 6 SATSUMA ZEPHYRHILLS, FL 1 Refer to NEC 312 8 for Conditions on taps in switcfN and over current devices Enclosures. If the conditions are not nte4 -'au box will need to be installed and revision completed. ' Godwin Engineering and �N C. Design, LLC 0. 81360 ® i 8378 Foxtail Loop n Pensacola, FL 32526 D. Chad Godwin, PE '" ° B STATE OF s � ® Chad odwinen com /A tORO� � i DrawnMM Revisedb : DMW . Date:1 77 [,"ja Inverter Type: Enphase LQ8A-72-2-US (26) Q.PEAK DOJO BLK ML-G10+ 405 Total Wattage: I0,530 DC System meets the grounding requirements of NEC 690.43 The Placard shall be permanently -A placard will be added with riveted..., and shall be made of red,l instructions and locations to be weatherproof, hard plastic, with 1 in compliance with 690.12, engraved white block lettering , 690.56(B) and NEC 705.10 Rapid Shutdown Built in In compliance with NEC` 250.58, N C 690.8, Per Code NEC 690.12 i NEC 250.24, NEC250.24(1)) PSI AC disconnect is Conductors have a min lockable in the open position ampacity of 60 amperes per code NEC 705.22(7) Per Code NEC 230.79(D) ing will be built to Code without all Specifics labeled on plan System is in compliance with FFPC 1:11.12 7th i,werter OucpsXt Cla __.. To vercurrera Pratection Cenci swnh Copper .. Design�remperature(F) S WFF..-r,__-.__.._.,_...._..._,_. Arne Temp Range#F} 87-95 �� 3f.0. --Max _ Eeas^pRat;ngof Coiductors(C) r� 75 L -11111-11 Current Carrying c4 3M � AC Max output Current i 38A 69 AC Max Wput Current * 1,25% 47A 6 Overcurrent Proterbono%j 50A _6tp -setup Gorree2:ian F3£Y£kf Raceway F01 adjustment actor Wire Ssze(Awg) Cond, Nlowad€e Atnpacity(A) Cond Adjusted Arrpacity(A) 4mpacity Check 1 Per 690,8(8)(1 kmpader Check 2 Per 690afS1(2 100a 310s5(BU(a) 6 310 lsis#.le# 6. A 65A'1*0{ 94--61AA -- Pass 37..7A'1,25=50Ac65A Pass Pass 65A*0.54A'1-61 AA7.7APass �AII Exterior equipment is A minimum of Nema-R3 Rated I -------- --- --- In compliance with 230.71 -- All Interactive System(S) Points of interconnection _ Markings shall be placed on all DC Conduits, DC Combiners, 1with other sources shall be marked at an accesible Combiner box in compliance Raceways, Enclosures, function loxes, and Cable Assemblies location at the disconnecting means as a power Per Code NEC 705.12 at every 10% turns, and above and below penetrations in source and with the rated ac output current and the 3 20A < 125A compliance with NFPA nominal operating AC voltage. Per NEC 690,54 Smoke Alarms ner F.S. 553.883 p 9 g No other loads to be added Disconnect means shall be provided for all disconnecting all ungrounded conductors that supply or pass through the building or structure Per Code 2017 NEC Section 225.31 & Section 225.32 E04. Construction documents specify PV system circuits installed on or in buildings include a rapid shutdown function that controls specific conductors in accordance with NEC article 690,12. E05. These construction documents specify that a label is provided with the method to initiate rapid shut down per 690.12(4). E06. Construction drawings specify buildings or structures with both utility service and a PV system, complying with NEC article 690.12 shall have a permanent plaque or directory including the following wording: "PHOTO VOLTAIC SYSTEM EQUIPPED WITH RAPID SHUTDOWN" as per NEC article 690.56 (C). E07. Construction documents specify PV power circuit labels shall appear on every section of the wiring system that is separated by enclosures, walls, partitions, ceilings; or floors. E08. Construction documents specify all warning sign(s) or label(s) shall comply with NEC article 110.21 (S). Label warnings shall adequately warn of the hazard. Labels shall be permanently affixed to the equipment, and Labels required shall be suitable for the environment. Over Current Protection Device is "Next size up" Based on Inverter Maximum Continuous Output Current Rating 2017 NEC 240.4(B) -All new equipment located adjacent to Meter on exterior wall Labels will be placed in the correct location Per Code NEC 690.56(B), 690.56(C), & 690.53 -All Electrical Service Equipment shall be located at or above BFE+For 8.00' NAVD -Markings Shall Be reflective Weather Resistant sand suitable foi the environment 1 -Markings Shall he reel with white ledac ring with mimmuni g` Capital Letters 12 tMi Include required label for metallic raceways and conduits to t-Subject PV Systems has been designed NFPA i 11.12.2.1, I.1. I and 11,12.2.1.3 �v 3/8 IN MIN. TEXT N, s .... fr <. 11 1ACE MET 9 IS Al S 3 E VED BY A PI IC3TC Va L'I"AIC SYSTEM 705.12(B)(3) - POWER SOURCE OUTPUT CONNECTION DO NOT RELOCATE THIS OVERCURRENT DEVICE 9MIMEMEM TURN RAPID i SHUTDOWN SWITCH Tq 3/16 IN MIN. TEXTi THE "OFF"POSITION TCI�pq7 SHUT DOWN PV �`�JW I SYSTEM AND REDUCE SHOCK HAZARD IN THE ` ARRAY. NEC 690.31 (G)(3) required label to sheet E-1 per NEC article 705.10. FloridaAdd and those set forth by the Solar Include required label to sheet Center Certification, Including capablePhotovoltaic AC disconnect shall be positionin the open a• per Photovoltaic AC Overcurrent protection shall be located Output,DO Maximum • NOT IOUCH TERM04ALS. 10 feet of the point where conductors are connected to 1 modelwithin the service per NEC 705.31 number, as applicable. NEC 690.13 Install will be done to Manufacturer S NEC 705,10 A permanent plaque or directory, denoting the location of ! i all electric power source disconnecting means on or in the premises, shall ` be installed at each service equipment location and at the location(s) of the system disconnect(s) for all electric power production sources capable I 1 of being interconnected. One sign required for each PV system. Plans Satisfy NEC 250.94 & NEC250.53(A)(2) Apply to Main Disconnect In Case of Emergency Call Voltage Pro Solar i Electric Inc Permanent sticker added to disconnect M ZEPHYRHILLS, FL • - 01 A11W 111 KIII a DW111011171W.1 aD Design, Pensacola, FL 32526 D. •d Godwin, P' Chad(o,godwinengxom Date: 5/25/2023 Drawn by: M Revised «, I Rev Date: • I► 1j _ Inverter 'Type: Enphase IQ8A-72-2-US (26) QYEAK DUO BLK ML-G10+ 405 Total Wattage: 101530W DC 'T 1 18 10 -Splice Bar 45 Quick Mount Flashings 60 Iron Ridge UFO's 16 Iron Ridge Sleeves/End Caps Roof Top Combiner 26 QYEAK DUO BLK ML-G 10+ 405 I 60A Fused Disconnect 2 50A Fuses 3 20A 2P Breakers I Enphase Combiner Box EM Rafter Spans Zone 1 1 Zone 2e I Zone 2n Zone 2r zone le Zone. se 48" 1 48" 24" 24024" 1124 No)]a­-kVPsed 721#—T 72" 72" 72" 72" 48" Max Cantilever, 29 29 29%f 29" 29" 1911 Max Cantilever = Max Span * (52 ) GaWlYIN&W W - - -- ---------- Inverter Type: (26)Enphase IQ8A-72-2-US PV Panel: (26) Q.PEAK DUO BLK ML-G 10+ 405 Racking: Iron Ridge XR- 100 Total Wattage: 10,530W DC ­ — - - .7 11 Wind Load: 21 to 27 Deg Fastener Type- Use 5/16" Ilia 4" Lags ®1 -7 # Modules (18) Pitch: 27' Azimuth: 269' R-2 # Modules (8) Pitch: 27' Azimuth: 89' COTTY RESIDENCE 5316 SATSUMA DRIVE ZEPHYRHILLS, FL 33542 Exposed Non -Exposed Spacing Spacing Plans satisfy zones FBC- 15 1 U.1 Install will be done to Manufacturej Design, LLC 8378 Foxtail Loop Pensacola, FL 3252 D. Chad Godwin, PE Ch g.com adggodwinen I Date: 5/25/2023 IVrawn by: Mm Ikevised DMB am 2 THE IDEAL SOLUTION FOR: 6n Rooftop arrays ion n residential buildings Engineered in Germany MECHANICAL SPECIFICATION -- t ° :p: 74 0 m x 41,iin x 26 in (including frame) 1879minx]046mnrx32 m) p-oas,*rr,} - s naxs mm7 xmm} _< < %,., n� CA 31r (3.2rnm) thermally pre -stressed glass with anti -reflection technology Composite film ."Mar, ao^s: Black anodized aluminum 6 x 22 monocrystalllne Q.ANTUM solar halt cells 'sir 209398in x L26-2.36inx059-071r l 53-101mm x 32-60mm x 15-18mm), iP67, with bypass diodes a R y i - - 4mmzSolar cable, {+l 492 r (725omr7),(}>49? in,{1250 nT} a� a=o<� • S aubli MC4; IP68 -. iz,-@zR,n7 o-Ernna 0la 'main , -f--C=_1 l6.33'(3.5 mmj V! �� ELECTRICAL ICAL "` HA ACT E € STi S _. �.. __ ._ ___,_.... _ _....._.._,..._.._.. _..._..,__ ...�. ------- _�....._._......_, ___ _. .....,_. _._ _. POWERCLASS 385 390 395 400 405 _ , _ --_-- , .2<.,..7 ... Ox 2.a , a.", ., .. ,S U%ry TOLERANCE , Oa Poorar _ t ""APPPull IWl 385 390 395 400 405 =C r I,a [A] 11,04 11.07 1110 1.i.14 11.17 ,,.x ,a.r fr z,_... , , ,,, ..-- ---_._._ ......____.�,------- R u 'ts � V� V ry 45,19 - � 45.23 .45 27 45.30 _ , ,- 45.34 ° inas [Al 10,59 10 65 10.71 10,77 10.83 TOP BRAND ry , � t . Q V, J] 36.36 3662 3688 3773 3739 F,5j ��y` if !] 19,6 199 201 >_204 20,6 xt suaave __ , ,. -, a f 926 03,8 Q@664y OCELLS nrta:Frr,�r - PNu`,..- [i�) „ �gg�_ -----. �8.9 2895-„897 39.00 a,oa,.a & Diu-1-tr ylvd Sec,.iro y _.._._..,.., w �. _ :s.°°rt ;'aPR.=.c)ra V,, [V] 42,62 42.65 42,69 42,72 42.76 r „ BREAKING THE 2°t° EFFICIENCY BARRIER '= Lurrant3111p,[Al 8�35 841 846 551 857 Q.ANTUM DUO Z Technology with zero gap cell layout Voltage at NAPP V ­ IV] 34.59 34 81 35.03 35,25 35 46 boosts module efficiency up to 20.9 %, 'Measurement tolerances P � sY � !sc V 5 %at SIC 000 v'6m 252 C AML5 according o E 60904-3 800 VA " Dil r spectrum AM 1.5 Q CELLS PERFORMANCE WARRANTY - - - g PERFORMANCE AT LOW IRRADIANCE 4-1 THE MOST THOROUGH TESTING PROGRAMME IN THE INDUSTRY 1=1 Q CELLS is the first solar module manufacturer to pass the most comprehen- sive quality programme in the Industry: The new "Quality Controlled PW of the independent certification institute TUV Rheinland. INNOVATIVE ALL-WEATHER R TECHNOLOGY Optimal yields, whatever the weather with excellent low -light and temperature behavior. ENDURING HIGH PERFORMANCE Long-term yield security with Anti LID Technology, Anti PID Technology', Not -Spot Protect and Traceable Quality Tra.QT"". EXTREME WEATHER RATiN High-tech aluminum alloy frame, certified for high snow (5400 Pa) and wind loads (4000 Pa). A RELIABLE INVESTMENT Inclusive 25 year product warranty and 25-year linear performance warranty'. APT test conditions -according to IEC/TS 62804-1:2015, method A (-1500 V, 96h) z See data sheet on rear for further information, GICELLS 2 At least 98%of nominal power during last year. Thereafter max. Q5% degradation per year. At least 93.5 % of nominal power up to 1.0 years. At least 86%of nominal power up to 25 years, uo is AIi data within measurement tolerant - es. Full warranties jr. accordance with 8°—- �a -- the warrenty terms or the Q CELLS saves organisation of your respective country, Typical module performance under low irradiance conditions in cpmparisonto STCcondil,ions(25"C,IOOOWim2I _.. _ TEMPERATURE COEFFICIENTS < p ar,ttt,e ry a [% /Kl +0.04 [°_ „ / }0.27 1 :.'r- toetfi,_._ ., y (%/Kj 0,34 Norninai .od,� ,aft.; w., 'Vhzi I'F] 109t5A43i3'C) PROPERTIES FOR YI E el DESIGN x ..:z.aSystem -yc@t _ [V] 1.000 (IEC)/1000 (UI_) < V Frry zif cc1iort Ches it ,x., .r,r, Se av Pu a a Ra 1i.,g [A DC] 20 F i rp a,1 C t }v na-,eo, aA rJt S tt,..,1 / 3 0 TYPE 2 tr bsJft] 75(3600Pa) f55(2660Pa) s u„x.> , 40'Fupro+185'F r-._ N Lc [lbs/ft2l 13 (5400 Pa)/84 (400OPa) utv 40'C u o r85'C e See installation Manual_-- QUALIFICATIiONS AND CERTIFICATES PAC AGiN G INFORh LAT.ION Ul lily o CE-c mpr nt• (�,i� (�f,/I g3 Quality ty Controlled PV TUV Rh e nfarrd, L IC 61216.201f IFC 6t7302b16,._..._.._..._._.._,,..._._.....0 P to t to 98932 (solar eus), r- 7641n 4331n 48,OIn 16561bs 24 24 32 Gt<Pv..e G1,�Yan on6oing. Cap,„,,, US aau ,.940mm 1100mrn 220mr-7 7t kg pallets pallets modules ._._ - _ _. _._.._... ....._�._ 5 is 111—n Note: installation instructions must oe followed. See the installation and operating manual or contact our technical service department for further information on approved installation and use of this product. Hanwha Q CELLS America Inc. 400 Spectrum Center Drive, Suite 1400, Irvine, CA 92618, USA I TEL 11949 748 59 961 E.=atAlL inquiryQus.q-cells.com I ;7VER www-q-ceils.us is our proprietary application -specific integrated circuit (ASIC) which enables the #941 55nm technology with high speed digital logic and has super -fast response times to chan-' ,-nergy systems. Connect PV modules quickly and easily to IQ8 Series Microinverters using the included 0-DCC-2 adapter cable with plug-n-play MC4 connectors. IQ8 Series Microinverters redefine reliability standards with more than one million cumulative hours of power -on testing, enabling an industry -leading limited warranty of up to 25 years. 108 Series Microinverters are UL Listed as PV Rapid Shut Down Equipment and conform with various regulations, when installed according to manufacturer's instructions. @ 2022 Enphase Energy. All rights reserved. Enphase, the Enphase logo, IQ8 Microinverters, and other names are trademarks of Enphase Energy, Inc. Data subject to change, IQBMA-DS-0003-01-EN-US-2022-03-17 Easy to install Lightweight and compact with plug-n-play connectors Power Line Communication (PLC) between components Faster installation with simple two -wire cabling High productivity and reliability Produce power even when the grid is down* More than one million cumulative hours of testing Class It double -insulated enclosure Optimized for the latest high- powered PV modules Microgrid-forming Complies with the latest advanced grid support — Remote automatic updates for the latest grid requirements Configurable to support a wide range of grid profiles Meets CA Rule 21 (UL 1741-SA) requirements Only when installed with IQ System Controller 2, meets UL 1741. 108M and 108A supports split phase, 240V installations only. 1Q8M and 1Q8A Microinverters Commonly used module pairings' W 260-460 295-500 Module compatibility 60-celf/120 half -cell, 66-cell/132 half -cell and 72-celf/144 half -cell MPPT voltage range v 33-45 36-45 Operating range V 25-58 Min/max start voltage V 30/58 Max input DC voltage v 60 Max DO current2 [module [so] A 15 Overvoltage class DC port If DO port backfeed current mA 0 PV array configuration lxI Ungrounded array; No additional DC side protection required; AC side protection requires max 20A per branch circuit Peak output power VA 330 366 Max continuous output power VA 325 349 Nominal (L-L) voltage/range3 V 240 / 211- 264 Max continuous output current A 1Z5 1.45 Nominal frequency Hz 60 Extended frequency range Hz 50-68 AC short circuit fault current over 2 3 cycles Arms Max units per 20 A (L-L) branch circuit' 11 Total harmonic distortion <5% Overvoltage class AC port III AC port backfeed current mA 30 Power factor setting 1.0 Grid -tied power factor (adjustable) 0.85 leading - 0.85 lagging Peak efficiency % 97.6 97.6 CEC weighted efficiency % 97 97.5 Night-time power consumption mw 60 Ambient temperature range -400C to +60°C (-40°F to +140°F) Relative humidity range 4% to 100% (condensing) DC Connector type MC4 Dimensions (HxWxD) 212 mm (8.3") x 175 mm (6.9") x 30.2 mm 0.2") Weight 1.08 kg (2,38 Ids) Cooling Natural convection - no fans Approved for wet locations Yes Pollution degree PD3 Enclosure Class It double -insulated, corrosion resistant polymeric enclosure Environ. category / UV exposure rating NEMA Type 6 / outdoor CA Rule 21 (UL 1741-SA), UL 62109-1, UL1741/IEEE1547, FCC Part 15 Class B, ICES-0003 Class B, CAN/CSA-C22.2 NO. 1071-01 Certifications This product is UL Listed as PV Rapid Shut Down Equipment and conforms with NEC 2014, NEC 2017, and NEC 2020 section 690,12 and C22.1-2018 Rule 64-218 Rapid Shutdown of PV Systems, for AC and DC conductors, when installed according to manufacturer's instructions. (1) No enforced DC/AC ratio. See the compatibility calculator at https://Iink,enphase.com/module-compatibility (2) Maximum continuous input DC current is 10.6A (3) Nominal voltage range can be extended beyond nominal if required by the utility. (4) Limits may vary. Refer to local requirements to define the number of microinverters per branch in your area. IQ8MA-DS-0003-01-EN-US-2022-03-17 LJ ,1 -T k4p 11111 1 i 1 %,� o L" I - cr, re"loo n, e, X2-IQ-AM1-240-4 (IEEE 1547:2018) (91 LWED Fo learn r-nore about Enphase offerings, visit gnphas e.j w M c IQ-C-4-4C-DS-0103-EN-US-12-29-2022 IQ Combiner 4/4C MODEL NUMBER IQ Combiner 4 IQ Combiner 4 with IQ Gateway printed circuit board for integrated revenue grade PV production mete' ring (ANSI C12,20 ± 0.5y) X-IQ-AMI-240-4 and consumption monitoring (± 2.5e). Includes a silver solar shield to match the IQ Battery arid IQ System Controller 2 and to X2-1Q-AM1-240-4 (IEEE 1547:2018) deffect heat. - ------------- IQ Combiner 4C !Q Combiner AC with IQ Gateway printed circuit board for integrated revenue grade PV production metering (ANSI C12.20 ± 0,5%) The IQ 4/4,C with IQ Gateway arid X-!Q-AM1-240 4C and consumption monitoring (12,5%). Includes Mobile Connect cellular modem (CELLMODEWMt-06-SP-05), a plug -and -play X2 IQ-AMI 240-4C (IEEE 1547:2018) industrial -grade cell modern fors up to 60 inicrorriverteio. (Available In the US, Canada, Mexico, Puerto Rico, and the Integrated 11 E-MI cell, moderin OnclUded US Virgin Islands, where there is adequate cellular service in the installation area) includes a silver solar shield to match the IQ Battery and IQ System Controller and to deflect heat, only with IQ Combiner 4C) consolidates ACCESSORIES AND REPLACEMENT PARTS (notincluded, order separately) Supported microinverters IQ6, IQ7, and IQ8. (Do not mix IQ6/7 Microinverters with IDS) interconnection equipment into a single Communications Kit enclosure. It strearrilines IQ Microinverters and COMMS CELLMODEM-MI-06 Includes COMMS-K] T 01 and CELLMODEM-Ml-06-SP 05 with 5-year Sprint data plan CELLMODEM-Ml-06-SP-05 4G based I-TE-Ml cellular modern with 5-year Sprint data plan storage installations by providing a consistent, CELLMODEM- MI-06-AT-05 AG based LTE-Ml cellular modem with 5-year A r &I data plan Circuit Breakers Supports Eaton BR210, BR215, BR220, BR230, BR240, BR250, and BR260 circuit breakers. pre -wired solution for residential applications. BRK-10A-2-240V Circuit breaker, 2 pole, 10A, Eaton BR21 0 BRK-15A-2-240V Circuit breaker, 2 pole, 15A, Eaton BR215 It offers uP to four 2-pole input circuits and BRK-20A-2P-240V Circuit breaker, 2 able, 20A, Eaton BR220 BRK-15A-2P-240V­B Circuit breaker, 2 pole, 15A, Eaton BR215B with hold down kit support Eaton BR series busbar assernbly. BRK-20A-2P-244V-B Circuit breaker, 2 pole, 20A, Eaton. BR220B with hold down kit support XA-SOL-ARSHIELD-ES Replacement solar shield for IQ Combiner 4/4C XA-PLUG-120-3 Accessory receptacle for Power Line Carrier it,. IQ Combiner 4/4C (required for EPI-C-01) X- IQ NA HD 125A Hold-down kit for Eaton circuit breaker with screws Consumption monitoring CT A pair of 200A split core current transformers Smart (CT-200-SPLIT/CT-200-CLAMP) ELECTRICAL SPECIFICATIONS Includes IQ Gateway for communication and control Rating Continuous duty Includes Mobile Connect cellular modem (CELLM(7DEM-101-06. SP-05), included only with System voltage 120/240VAC, 60 Hz IQ Combiner 4C Eaton BR series busbar rating 125A Includes solar shield to match Enphase IQ Battery Max. continuous currentrazing 65A aesthetics and deflect heat Max. continuous current rating driputfrom PtAstorage) 64A Supports Wi-Fi, Ethernet, or cellular connectivity Max. fuse/circuit rating (output) 90A Optional AC receptacle available for PLC bridge Branch circuits (solar and/or storage) Up to four 2-pole Eaton BR series Dist, ibuted Generation (DG) breakers only (not included) Provides production metering and consumption Max. total branch circuit breaker rating (input) 80A of distributed generation/95A with IQ Gateway breaker included monitoring IQ Gateway breaker 10A or 15A rating GE/Siemens/Eation included Production metering CT 200A solid core pre -installed and wired to IQ Gateway Simple MECHANICAL DATA Mounts on single stud with centered brackets rmensions (WxHxD) . .. .... ......... ... .... . .... .... 37.5 cm x 49.5 cm x 1,6_8 are (14,75 in x 19.5 in x 6.63 in) Height is 53.5 cm (21-06 in) with mounting brackets•. Supports bottom, back and side conduit entry Weigh, T5 kg (16.5 ps) Allows up to four 2-pole branch circuits for 240VAC Ambient temperature range -401C to +461C (-401F to 11 51F) plug-in breakers (not included) Cooling Natural convection, plus heat shield 80A total PV or storage branch circuits Enclosure environmental rating Outdoor, NRTL-certified, NEMA type 3R, polycarbonate construction Wire sizes 20A to 50A breaker inputs: 14 to 4 AWG copper conductors Reliable 60A breaker branch input: 4 to 1/0 AWG copper conductors Main lug combined output: 10 to 2/0 AWG copper conductors Neutral and ground: 14 to 1 /0 copper conductors Durable NRTL-cerfified NEMA type 3R enclosure Always follow local code requirements for conductor sizing. Five-year limited warranty Altitude Up to 3,000 meters (9,842 feet) Two years labor reimbursement program coverage INTERNET CONNECTION OPTIONS included for both the IQ Combiner SKU's Integrated Wi-Fi IEEE 802-Ilb/g/n UL listed X2-IQ-AM1-240-4 and X2-IQ-AMI-240-4C comply with Cellular CELLLMODEM-Ml-06-SP 05, CELLMODEM-Ml -06-AT-05 (4G based LTE-Ml cellular modern). Note that an Mobile Connect cellular modem is required for all Enphase Eneigy System installations. IEEE 1547:2018 (UL 1741-SB, V Ed.) Ethernet Optional, IEEE 802.3, Cat5E (or CaIA) UTP Ethernet cable (not included) COMPLIANCE Compltance,IQ Combiner . . .............. ..... CA Rule 21 (UL 1741-SA) IEEE 1547:2018 -UL 1741-SB,31dEd. (X2-1Q-AM1-240-4 and X2-IQ-AM1-240-4C) CANICSA C22.2 No. 107.1. Title 47 CFR, Part 15, Class B, ICES 003 Production metering: ANSI C12.20 accuracy class 0.5 (PV production) N1_1z__1 ENPHASEConsumption metering: accuracy class 2.5 Compliance, IQ Gateway UL 60601 - I /CANCSA 22.2 No 61010-1 2022 Pnphase Energy Ali ,rohts,eservcc hase,theFriphase lOgO, 10 COMbiner 4/4C,and other names, tladeirajdks of Fnphase Friergy, Inc Data subject to change IQ-C-4-4C-DS-0103-EN-US-12-29-2022 AWk IRONRIDGE XR Rail Family Over their lifetime, solar panels experience countless extreme weather events. Not just the worst storms in years, but the worst storms in 40 years. High winds capable of ripping panels from a roof, and snowfalls weighing enough to buckle a panel frame. A Sloped roofs generate both vertical and lateral forces on mounting rails which can cause them to bend and twist. The curved shape of XR Rails is specially designed to increase strength in both directions while resisting the twisting. This unique feature ensures greater security during extreme weather and a longer system lifetime. r Compatible with Flat & Pitched Roofs 'N XR Rails are IronRidge offers I gl compatible with s UP/ 02 0 c� 0 a range of tilt leg OsIsg -A FlashF t and "g—,"A 00 s options for flat -"N other pitched roof awaism A0 W �,Ns roof mounting M attachments. ,p K, applications. Iowa I "M WWWW""111 umu��� amil 6'spanning capability Moderate load capability Clear & black anodized finish Internal splices available M0161 al ---- XR100 is the ultimate residential mounting rail. It supports a range of wino and snow conditions, while also maximizing spans up to 10 feet. 10' spanning capability Heavy load capability Clear & black anodized finish Internal splices available lit XR1000 is a heavyweight among solar mounting rails. It's built to handle extreme climates and spans up to 12 feet for commercial applications. Table is meant to be, a sirt-tDi'fied span chart for conveying gene.alcapabilities. Use, approved cerfification ':ettorf; for actual design guidance. 8378 Foxtail Loop, Pensacola, FL 32583 1 (850)712-4219 1 chad Eaodw September 12, 2023 To: City of Zephyrhills Building Department 5335 8th Street Zephyrhills, FL 33542 (813) 780-0020 Re: Catty Residence - Residential PV Installation 5316 Satsuma Dr. Zephyrhills, FL 33542 To whom it may concern, A. This letter is to inform the inspector of the amendment to the proposed Solar PV system at the address above. 1RHMM 1. Changing module wattage. 1. Adjusted the modules wattage on all pages. 2. Adjusted the total wattage of the PV system on all pages. 3. Changes are clouded. Please contact me if you have any questions. D. Chad Godwin, PE 81360 Exp.2/28/25