Loading...
HomeMy WebLinkAbout23-63877111MI-717 RITI"'ITO 5335 Eighth Street Zephyrhills, FL 33542 Phone: (813) 780-0020 Fax: (813) 780-0021 issue Date: 06/08/2023 REINSPECTION FEES: (c) With respect to Reinspection fees will comply with Florida Statute 553.80(2)(c) the local government shall impose a fee of four times the amount of the fee imposed for the initial inspection or first reinspection, whichever is greater, for each subsequent reinspection. Notice: In addition to the requirements of this permit, there may be additional restrictions applicable to this property that may be found in the public records of this county, and there may be additional permit required from other governmental entities such as water management, state agencies or federal agencies. improvements to your property. If you intend to obtain financing, consult with your lender or an attorney 97-RTMEMM 0 0 * I - Complete Plans, Specifications add fee Must Accompany Application. All work shall be performed in accordance with City Codes and Ordinances. NO OCCUPANCY BEFORE C.O. NO OCCUPANCY BEFORE C.O. CONTRACTOR SIG E PE IT OFFICE[) I,, PERMIT EXPIRES IN 6 MONTHS WITHOUT APPROVED INSPECTION buiming uelparrmenT Date Received 141 2 1 1 t I t Owner's Name Owner's Address Fee Simple Titleh 1 nittin FT17-5-14V Owner Phone Number Owner Phone Number Owner Phone Number Fee Simple Titleholder Address I JOB ADDRESS LOT # SUBDIVISION MU�c"PARCEL ID# (OBTAINED FROM PROPERTY TAX NOTICE) WORK PROPOSED NEW CONSTR ADD/ALT SIGN = DEMOLISH El INSTALL REPAIR PROPOSED USE SFR COMM OTHER TYPE OF CONSTRUCTION BLOCK FRAME STEEL DESCRIPTION OF WORK I C6, `iIJ W WJb::1LZ1GH1 gj BUILDING SIZE SQ FOOTAGE HEIGHT VALUATION OF TOTAL CONSTRUCTION ,=ELECTRICAL Is AMP SERVICE PROGRESS ENERGY W.R.E.C. =PLUMBING 1$ =MECHANICAL 1$ =GAS ROOFING FINISHED FLOOR ELEVATIONS VALUATION OF MECHANICAL INSTALLATION SPECIALTY = OTHER FLOOD ZONE AREA =YES NO BUILDER COMP ANY REGISTERED LLLN FEE CURREN LZ SIGNATURE _LN Address License # —7 ELECTRICIAN COMPANY C I C (On)TO MUP SIGNATURE REGISTERED YIN FEE CURREN �N N Address;,„AIM i�e License # PLUMBER COMPANY SIGNATURE l REGISTERED Address License# MECHANICAL COMPANY SIGNATURE REGISTERED L_Z_LN FEE CURREN I Y/N Address License #E=:=== OTHER COMPANY SIGNATURE REGISTERED Y/N FEE CURREN Address License# RESIDENTIAL Attach (2) Plot Plans; (2) sets of Building Plans; (1) set of Energy Forms; R-O-W Permit for new construction, Minimum ten (10) working days after submittal date. Required onsite, Construction Plans, Stormwater Plans w/ Silt Fence installed, Sanitary Facilities & 1 clumpster; Site Work Permit for subdivisions/large projects COMMERCIAL Attach (2) complete sets of Building Plans plus a Life Safety Page, (1) set of Energy Forms. R-O-W Permit for new construction. Minimum ten (10) working clays after submittal date. Required onsite, Construction Plans, Stormwater Plans w/ Silt Fence installed, Sanitary Facilities & 1 clumpster. Site Work Permit for all new projects. All commercial requirements must meet compliance SIGN PERMIT Attach (2) sets of Engineered Plans. ****PROPERTY SURVEY required for all NEW construction. Directions: Fill out application completely. Owner & Contractor sign back of application, notarized If over $2500, a Notice of Commencement is required. (A/C upgrades over $7500) .1 Agent (for the contractor) or Power of Attorney (for the owner) would be someone with notarized letter from owner authorizing same OVER THE COUNTER PERMITTING (copy of contract required) Reroofs if shingles Sewers Service Upgrades A/C Fences (Plot/Survey/Footage) Driveways -Not over Counter if on public roadways.,needs ROW Building Department NOTICE OF DEED RESTRICTIONS: The undersigned understands that this permit may be subject to "deed" restrictions" which may be more restrictive than County regulations. The undersigned assumes responsibility for compliance with any applicable deed restrictions. UNLICENSED CONTRACTORS AND CONTRACTOR RESPONSIBILITIES: If the owner has hired a contractor or contractors to undertake work, they may be required to be licensed in accordance with state and local regulations. If the contractor is not licensed as required by law, both the owner and contractor may be cited for a misdemeanor violation under state law. If the owner or intended contractor are uncertain as to what licensing requirements may apply for the intended work, they are advised to contact the Pasco County Building Inspection Division —Licensing Section at 727-847- 8009, Furthermore, if the owner has hired a contractor or contractors, he is advised to have the contractor(s) sign portions of the "contractor Block" of this application for which they will be responsible. If you, as the owner sign as the contractor, that may be an indication that he is not properly licensed and is not entitled to permitting privileges in Pasco County. TRANSPORTATION IMPACT/UTILITIES IMPACT AND RESOURCE RECOVERY FEES: The undersigned understands that Transportation Impact Fees and Recourse Recovery Fees may apply to the construction of new buildings, change of use in existing buildings, or expansion of existing buildings, as specified in Pasco County Ordinance number 89-07 and 90-07, as amended. The undersigned also understands, that such fees, as may be due, will be identified at the time of permitting. It is further understood that Transportation Impact Fees and Resource Recovery Fees must be paid prior to receiving a `certificate of occupancy" or final power release. If the project does not involve a certificate of occupancy or final power release, the fees must be paid prior to permit issuance. Furthermore, if Pasco County Water/Sewer Impact fees are due, they must be paid prior to permit issuance in accordance with applicable Pasco County ordinances. CONSTRUCTION LIEN LAW (Chapter713, Florida Statutes, as amended): If valuation of work is $2,500.00 or more, I certify that I, the applicant, have been provided with a copy of the "Florida Construction Lien Law —Homeowner's Protection Guide" prepared by the Florida Department of Agriculture and Consumer Affairs. if the applicant is someone other than the "owner", I certify that I have obtained a copy of the above described document and promise in good faith to deliver it to the "owner' prior to commencement. CONTRACTOR'S/OWNER'S AFFIDAVIT: I certify that all the information in this application is accurate and that all work will be done in compliance with all applicable laws regulating construction, zoning and land development. Application is hereby made to obtain a permit to do work and installation as indicated. I certify that no work or installation has commenced prior to issuance of a permit and that all work will be performed to meet standards of all laws regulating construction, County and City codes, zoning regulations, and land development regulations in the jurisdiction. I also certify that I understand that the regulations of other government agencies may apply to the intended work, and that it is my responsibility to identify what actions I must take to be in compliance. Such agencies include but are not limited to: Department of Environmental Protection -Cypress Bayheads, Wetland Areas and Environmentally Sensitive Lands, Water/Wastewater Treatment. Southwest Florida Water Management District -Wells, Cypress Bayheads, Wetland Areas, Altering Watercourses. Army Corps of Engineers -Seawalls, Docks, Navigable Waterways. Department of Health & Rehabilitative Services/Environmental Health Unit -Wells, Wastewater Treatment, Septic Tanks. US Environmental Protection Agency -Asbestos abatement. Federal Aviation Authority -Runways. I understand that the following restrictions apply to the use of fill: Use of fill is not allowed in Flood Zone W" unless expressly permitted. If the fill material is to be used in Flood Zone "A", it is understood that a drainage plan addressing a compensating volume" will be submitted at time of permitting which is prepared by a professional engineer licensed by the State of Florida. If the fill material is to be used in Flood Zone "A" in connection with a permitted building using stem wall construction, I certify that fill will be used only to fill the area within the stem wall. If fill material is to be used in any area, I certify that use of such fill will not adversely affect adjacent properties. If use of fill is found to adversely affect adjacent properties, the owner may be cited for violating the conditions of the building permit issued under the attached permit application, for lots less than one (1) acre which are elevated by fill, an engineered drainage plan is required. If I am the AGENT FOR THE OWNER, I promise in good faith to inform the owner of the permitting conditions set forth in this affidavit prior to commencing construction. I understand that a separate permit may be required for electrical work, plumbing, signs, wells, pools, air conditioning, gas, or other installations not specifically included in the application. A permit issued shall be construed to be a license to proceed with the work and not as authority to violate, cancel, alter, or set aside any provisions of the technical codes, nor shall issuance of a permit prevent the Building Official from thereafter requiring a correction of errors in plans, construction or violations of any codes. Every permit issued shall become invalid unless the work authorized by such pen -nit is commenced within six months of permit issuance, or if work authorized by the permit is suspended or abandoned for a period of six (6) months after the time the work is commenced. An extension may be requested, in writing, from the Building Official for a period not to exceed ninety (90) days and will demonstrate justifiable cause for the extension. If work ceases for ninety (90) consecutive days, the job is considered abandoned. WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENQER OR AN ATTQRN O RECORDING [OUR NOTICE OF COMMENCEMENT. FLORIDA JURAT (F.S. 117.03) OWNER OR AGENT CONTRACT0,11 46KI'ta,e „ and sworn to or a irmed)P fore me this Sscri an sworn to (or affirmed) b ore me Athis by L t i _by person I know to me or has/have produced Who is/gare ersona y nown to me or has/have prod ced as identification. F as identification. d ' Notary Public tz Natary Public Commission No. Commission N Name o Notary typed, printed or stamped Name of Notary typed, printed or stamped V P "' "4 „�+ t t ..State of t K i5a .,�QAXI t. Not r I CAA; 1 S ia..E. o,f FF 'C 1, da �' Olivia i t� ,�� f a i t 1 ' C,i <<j it l c Jt`�?' `gym 4 xpi G , FUSION »��r � �, i g May 3l.2023 Lmnex Power hX24SManhattan Ave Tampa, FL 33616 RE Wilber Residence 7O20Shelby Lynn Way, Zephyrhills,FL33542 Client Project #:7O20\Vi]b PFEProject #: 232009 0obehalf of Luuex Power, Penn Fusion Engineering DC (PFE) performed mstructural analysis ofthe roof at the above referenced location. The purpose of our analysis was to determine if the existing roof system is structurally sufficient to support the new photovoltaic modules in addition to the code required design loads. Our analysis is based on the information provided byLuoex Power and is limited only to the areas where the noodu\cu are intended oobc placed. System Specifications Panel Snecx:(l8) Hyperion Solar Hy-D8|O8y8-4OOB4OOVV Racking System: K2 - 44-X The modules are tohclocated outhe following roof planes: This office has determined that the existing roof as specified above will meet the structural requirements of the above If you have any questions regarding this analysis, please feel free to contact us. we Regards, Pein Fusion 1 r Andrew D. Leone, P.E. Principal Ny Penn Fusion Engineering LLC - 152 S. Broad St. - Lansdale, PA 19446 - 215-361-8040 LUNEX POWER INC. 4721 N GRADY AVE TAPA FL 33614 LIC ##: CVC57085 PHONE: 813-540-8807 REVISIONS DESCRIPTION -_ DATE REV JJJ DATE: 05/31 /2023 PROJECT NAME & ADDRESS } N Q dt UJ z uj J co z } LL J J U6 m � %' ct) W LL U) _ 00 CL cal W O ti ,- v- i t = L�..tvtrrvsciv o >rrct,'rla.,r� I svrvJ CODE REFERENCES DRAWN BY ESR 18. DISCONNECTING MEANS SHALL BE LOCATED IN A VISIBLE, READILY ACCESSIBLE LOCATION WITHIN THE PV SYSTEM OR A MAXIMUM OF 10 FEET AWAY FROM THE SYSTEM [NEC 690.13(A)] PROFESSIONALEQUIPMENT PROJECT TO COMPLY WITH THE FOLLOWING: 19. ALL WIRING METHODS SHALL BE IN ACCORDANCE WITH NEC 690.31 FLORIDA RESIDENTIAL CODE, 7TH EDITION 2020 (FRC) SHEET NAME 20. WORK CLEARANCES AROUND ELECTRICAL EQUIPMENT WILL BE MAINTAINED PER NEC 110.26(A)(1), 110.26(A)(2) AND 110.26(A)(3). 21. ROOFTOP MOUNTED PHOTOVOLTAIC PANELS AND MODULES SHALL BE TESTED, LISTED & IDENTIFIED IN ACCORDANCE WITH UL1703 FLORIDA PLUMBING CODE, 7TH EDITION 2020 (FPC) FLORIDA BUILDING CODE, 7TH EDITION 2020 EDITION (FBC) FLORIDA MECHANICAL CODE, 7TH EDITION 2020 (FMC) 2017 NATIONAL ELECTRICAL CODE COVER SHEET SHEET SIZE 22. ELECTRICAL CONTRACTOR TO PROVIDE CONDUIT EXPANSION JOINTS AND ANCHOR CONDUIT RUNS AS REQUIRED PER NEC. FLORIDA FIRE PREVENTION CODE, 7TH EDITION (FFPC) ANSI S 23. THE ENCHARGE BATTERY AS PART OF THE ENSEMBLE SYSTEM DOES NOT EXPORT POWER TO THE GRID IN ANY STORAGE 11 " X 1 7" MODE. — SHEET NUMBER V-1 NUMBER OF MODULES = 18 MODULES MODULE TYPE = HYPERION SOLAR: HY-DH108P8-400B 40OW MONO MODULES MODULE WEIGHT = 55.55 LBS 11 r- lLllW--6tlQlnlAQ - f.."7 *0" ROOF DESCRIPTION TRUSS SPACING LUNSXROW�R LUNEX POWER INC. 4721 N GRADY AVE TAMPA FL 33614 LIC #: CVC57085 PHONE: 813-540-8807 REVISIONS DESCRIPTION DATE REV DATE: 05/31/2023 PROJECT NAME & ADDRESS >: 04 < eq- �: cif LJJ c1l) c) _j Z >- w -j co U) LLJ w T- LL- U) co 04 W 0 N rz- DRAWN BY ESR SHEET NAME ROOF PLAN & MODULES SHEET SIZE ANSI B 11" X 17" SHEET NUMBER PV-3 m1 Lai ' * - aMEAL, � i ' •i 2 """ ATTACHMENT DETAIL (ENLARG PV-5 LUNEX POWER INC. 4721 N CRADY AVE TAMPA FL 33614 LIC #: CVC57085 PHONE: 813-540-8807 REVISIONS DESCRIPTION DATE REV DATE: 05/31 /2023 PROJECT NAME & ADDRESS > N Q} c') Z _j Z J LL ®1 u m J J = LLJ L L_ U) _ 00 CL N LLJ 1�- DRAWN BY ESR SHEET NAME STRUCTURAL DETAIL SHEET SIZE ANSI 11" X 17"} SHEET NUMBER t V — DC SYSTEM SIZE: 18 x 400 = 7,200 kW DC AC SYSTEM SIZE: 18 x 290 = 5.220 kW AC (18) HYPERION SOLAR: HY-DH108P8-400B 40OW MONO MODULES WITH (18) ENPHASE: IQ8PLUS-72-2-US (240V) MICROINVERTERS (COMPLIANT WITH RAPID SHUTDOWN) (2) BRANCH CIRCUITS OF 9 MODULES ARE CONNECTED IN PARALLEL ENPHASE IQ-SYSTEM-CONTROLLER-2 NOTE: THE ENPHASE IQ -SYSTEM CONTROLLER 2 CONNECTS THE HOME TO GRID POWER, THE ENCHARGE STORAGE SYSTEM, AND SOLAR PV. IT PROVIDES MICROGRID INTERCONNECTION DEVICE (MID) FUNCTIONALITY BY AUTOMATICALLY DETECTING AND SEAMLESSLY TRANSITIONING THE HOME ENERGY SYSTEM FROM GRID POWER TO BACKUP POWER IN THE EVENT OF A GRID FAILURE. IT CONSOLIDATES INTERCONNECTION EQUIPMENT INTO A SINGLE ENCLOSURE AND STREAMLINES GRID INDEPENDENT CAPABILITIES OF PV AND STORAGE INSTALLATIONS BY PROVIDING A CONSISTENT, PRE -WIRED SOLUTION FOR RESIDENTIAL APPLICATIONS. (18) HYPERION SOLAR: HY-DH108P8-4008 40OW MODULES £ BRANCH#1 7 1 2 3 0 o oS 9 _BRANCH #<m� i 1 2 3 0 o 0 8 9 I - + - + BRANCH TERMINATOR (ET -TERM) (18) ENPHASE:IQ8PLUS-72-2-US (240V) MICROINVERTERS (COMPLIANT WITH RAPID SHUTDOWN) LOCATED UNDER EACH PANEL SOLADECK, 606V, NEMA 3R, UL LISTED t.. 1 ELECTRICAL LINE DIAGRA (:Dc, PV-6 SCALE: NTS INTERCONNECTION NOTES: 1. INTERCONNECTION SIZING, LIMITATIONS AND COMPLIANCE DETERMINED IN ACCORDANCE WITH [NEC 705.12), AND [NEC 690.59]. 2. GROUND FAULT PROTECTION IN ACCORDANCE WITH [NEC 215.9], [NEC 230.951. 3. ALL EQUIPMENT TO BE RATED FOR BACKFEEDING. 4. PV BREAKER TO BE POSITIONED AT THE OPPOSITE END OF THE BUSBAR RELATIVE TO THE MAIN BREAKER. DISCONNECT NOTES: 1. DISCONNECTING SWITCHES SHALL BE WIRED SUCH THAT WHEN THE SWITCH IS OPENED THE CONDUCTORS REMAINING LIVE ARE CONNECTED TO THE TERMINALS MARKED "LINE SIDE" (TYPICALLY THE UPPER TERMINALS) 2. AC DISCONNECT MUST BE ACCESSIBLE TO QUALIFIED UTILITY PERSONNEL, BE LOCKABLE, AND BE A VISIBLE -BREAK SWITCH 3. DISCONNECT MEANS AND THEIR LOCATION SHALL BE IN ACCORDANCE WITH [NEC 225.31] AND [NEC 225.321. NOTE:RACKING 1. :O • EVERY • A GROUNDING & GENERAL NOTES: 1- GROUNDING ELECTRODES AND GROUNDING ELECTRODE CONDUCTORS. ADDITIONAL GROUNDING ELECTRODES SHALL BE PERMITTED TO BE INSTALLED IN ACCORDANCE WITH 250.52 AND 250.54.GROUNDING ELECTRODES SHALL BE PERMITTED TO BE CONNECTED DIRECTLY TO THE PV MODULE FRAME(S) OR SUPPORT STRUCTURE PER [NEC 690.47(B)] 2, PV INVERTER IS UNGROUNDED, TRANSFORMER -LESS TYPE. 3. DC GEC AND AC EGC TO REMAIN UNSPLICED, OR SPLICED TO EXISTING ELECTRODE 4. ANY EXISTING WIRING INVOLVED WITH PV SYSTEM CONNECTION THAT IS FOUND TO BE INADEQUATE PER CODE SHALL BE CORRECTED PRIOR TO FINAL INSPECTION. 5. SOLADECK QUANTITIES, AND PLACEMENT SUBJECT TO CHANGE IN THE FIELD - SOLADECK DEPICTED ON ELECTRICAL DIAGRAM REPRESENT WIRE TYPE TRANSITIONS. 6. AC DISCONNECT NOTED IN EQUIPMENT SCHEDULE OPTIONAL IF OTHER AC DISCONNECTING MEANS IS LOCATED WITHIN 10' OF SERVICE DISCONNECT. 7. RACEWAYS AND CABLES EXPOSED TO SUNLIGHT ON ROOFTOPS SHOULD BE INSTALLED MORE THAN 7/8" ABOVE THE ROOF USING CONDUIT SUPPORTS. 7 € } % RU CK € € 21078A X t25 = 27 22A ESS AC LOAD 16A X 1.25 = 20A TO UTILITY GRID DI1CONNECT#2 I 27.225A+20A = 4Z225A LOLLI240V, 1�, 3W ( 240A-175A = 65A>50A, OKAY L? L2 N (N) ENPHASE 30A RATED i ENCHARGE-10-1P-NA NEMA 3R € ENPHASE IQ SYSTEM CONTROLLER 2 BATTERY E IS EQUIPPED WI M.LO. WICRO-GRID IN) ENPHASE IQ SYSTEM ISLANDING DEVICE)- WHICH DURING DERATE MAIN LINE CONTROLLER 2 A GRID OUTAGE. WILL OPEN AND NOT BREAKER FROM 26tlA Ig BI-DIRECTIONAL EP200GI01-M240US01 ALLOW BACKFEED TO THE GRID. RATED TO 175A [�(] UTILITY METER g NEMA 3R, 200A RATED, 240V 120/240V 1�, 3-W n ENPHASE X-10-AM1-240-4/4C e=N ONE LOAD AC COMBINER BOX- NEUTRAL 120/240VAC, 1�, 3W _ i A ! 125A RATED BUS BAR, NEMA 3R FORMING SOLAR LOADS ONLY 'G'N L'2 1 @ XFMR L UL 1741 COMPLIANT L2 F PV AC DISCONNECT#1 rrN AC DISCONNECT#3/'�''� 240V.. I+. 3W "-"""" B M.LD 240V, I�, 3W t CU 1 30A RATED ( 60A RAPED --LL"--; (N) MAIN BREAKER TO �-./ i NEMA 3R i enrr NFr NEMA 3R 4 G ( HOUSE 240V 175Al2P z0w2 4 2P -` I (E) MAIN METER COMBO IQ § I # F 200A RATED, 240V GATEWAY - I.{OLp� { EEES I 50A/2P j LINE DOWN KIT {({j ( J [ I I LOAD SIDE �arlP asuzr> 8 9 ) INTERCONNECTION AT 7 I Ell QDATF f # j MAIN PANELJSUB-PANEL PER ART. 705.12 BACKFEED BREAKER 4 0* r T IFEE LOAD G Lt _ j_ G 2017 NEC 705-12(B)f27(3)@} 20N2P � � hEUTanL cRouNc LOAD ,N t k t L I � L Ll. I� .. ..�_ ...--...�..,._ "r GEC VISIBLE, LOCKABLE, 44 £ ' 12 LABELED AC DISCONNECT 3 i ) „ �—'— -- ---" i-a--a ( 'r ;, EXISTING GROUNDING U N 6 LOCATED WIT IN 10' , - I J L2 "- -- e _ OF UTILITY METER "` ELECTRODE SYSTEM TO G ,- ° £ EARTH REF. NEC 250.52, ENPHASE SYSTEM ( 250.53(A) SHUTDOWN SWITCH {, f Li E r, ILI 2. N.., G .-... QTY CONDUCTOR INFORMATION CONDUIT TYPE CONDUIT SIZE (4) #1 ZAWG - Q CABLE (L1 & L2 NO NEUTRAL) N/A N/A (1) #6AWG - BARE COPPER IN FREE AIR (4) #10AWG- THWN-2 (L1,L2) (EXTERIOR) #10/2 ROMEX (1) #10AWG - THWN-2 GND IN ATTIC EMT OR LFMC IN ATTIC 3/4" (2) #10AWG THWN-2 (L1,L2) (1) #10AWG- THWN-2 N EMT, LFMC OR LFNC 314" (1) #10AWG- THWN-2GND (2) #10AWG- THWN-2 (L 1 , L2) (1) #10AWG- THWN-2 GND EMT, LFMC OR LFNC 3/4" (2) #10AWG- THWN-2(L1,L2) (1) #10AWG- THWN-2 N EMT, LFMC OR LFNC 3/4" (1) #10AWG- THWN-2GND (2) #12AWG THWN-2 (Lt L2) (1) #12AWG - THWN-2 N EMT, LFMC OR LFNC 3/4" (1) #10AWG - THWN-2 GND (27 #8AWG - - . (1) #8AWG- THWN2N 3/4" (1) #10AWG- -- THWN-2 GND EMT, LFMC OR LFNC I —I (N) MAIN BREAKER TO HOUSE 240V, 50A/2P (N) BACKUP PANEL, k 100A RATED, 240V N (D ENPOWER MAIN LUG RATED FOR #1 AWG-350 KcmiL-(ALL SMALLER WIRE TERMINATIONS REQUIRED U L RING TERMINAL.) B ENPOWER DRY CONTACTOR RATINGS- 12V - 24V MAX. (1A) COMMUNICATION KIT L! - LUNEX POWER INC. 4721 N GRADY AVE TAMPA FL 33614 LIC #: CVC57085 PHONE: 813-540-8807 REVISIONS DESCRIPTION DATE REV �o DATE: 05/31 /2023 PROJECT NAME & ADDRESS Lo W Z U _j } J w J B tl V J LL[ < =/) /W oo LJ DRAWNBY ESR SHEET NAME ELECTRICAL LINE DIAGRAM SHEET SIZE ANSI 11" X 17" SHEET NUMBER PV-6 INVERTER SPECIFICATIONS MANUFACTURER / MODEL # ENPHASE: IQ8PLUS-72-2-US (240V) MICROINVERTERS (COMPLIANT WITH RAPID SHUTDOWN) MIN/MAX DC VOLT RATING 30V MIN/ 58V MAX MAX INPUT POWER 235W-440W NOMINAL AC VOLTAGE RATING 240V/ 211-264V MAX AC CURRENT 1.21A MAX MODULES PER CIRCUIT 13 (SINGLE PHASE) MAX OUTPUT POWER 290 VA SOLAR MODULE SPECIFICATIONS MANUFACTURER / MODEL # HYPERION SOLAR: HY-DH108P8-400B 40OW MODULE VMP 31.01 V IMP 12.90A VOC 37.07V ISO 13.79A TEMP. COEFF. VOC -0.27%/°C MODULE DIMENSION 67.08"L x 44.65"W x 1.18"D (In Inch) AMBIENT TEMPERATURE SPECS RECORD LOW TEMP -1. AMBIENT TEMP (HIGH TEMP 2%) 35- MODULE TEMPERATURE COEFFICIENT OF Voc -0.27%/°C PERCENT OF VALUES NUMBER OF CURRENT CARRYING CONDUCTORS IN EMT .80 4-6 .70 7-9 .50 10-20 AC CALCULATIONS ORIGIN CaRtX9ST DESTINATIONAMPS VOLTAGE (ifp FULL LOAD AMPS "FLA"` (A) (A) OC'.PE� SIZE (A) NEUTRAL roZ€ GROUND 582E. CONDUCTOR SIZE 75aC AMPACITY AMPAC9TY (A) C4iECK #1 AMBIENT TEMP, (QCp TOTAL CC CONDUCTORS IN RA, AY CiERATtON FACTOR 901C FOR AMBIENT AMPACCiY {A} TEMPERATURE NEC 320.15(8)(2)(a) OERATION FACTOR FOR CONDUCTORS PER RACEWAY NEC 310.15(B)(3)(a) 901C AMPACITY DEBATED (A) AMPACITY CH#2 FEEDER LENGTH (FEET) CONDUCTOR RESISTANCE (OHM/KFT) VOLTAGE DROP AT FLA (%) CONDUIT CONDUITCIRCUIT 592E Fitt (""/o) CIRCUIT 1 SOLADECK 240 10,89 13.622E 20 NIA BARE COPPER #6 AWG CU #12 AWG 25 A.S> 35 2 30 0.96 c 28,8 PASS 0.310 N/A CIRCUIT 2 SOLADECX 240 IC99 13,6125 20 N/A BARE COPPER #6 AlhfG CU #'12 AING 25 PASS 35 2 30 0.96 288 PASS 0,380 NI/A SOLADECK COMBINER BOX 240 10-99 13.6125 20 N/A CU #10 AWG CU #10 AWG 35 PASS 35 4 40 c3.96 0.9 3072 `A,,S 34 1,24 0.729 i 3/4" EMT COMBINER BOX AC DISCONNECT 240 211-78 27.225 30 CU #10 AWG CU #10 AWG CU #10AWG 35'PS SS 35 2 40 0.96 1 38A PASS 5 1.24 0.113 3/4" EMT AC DISCONNECT TRANSFER WATCH 240 2138 27.225 Sit CU #10 AVIG CU #10 AWE, CU #10 AWG 35 PASS 35 2 46 0.96 2 38A PASS 5 1.24 0.27.3 3/4" EMT TRANSFER SWITCH - - BATTERY AC DISCONNECT BATTERY AC DISCONNECT ------ -...-------------._ BATTERY 240 _..-------- 240 1.6 --- 16 20 ..._...._..- 20 20 -- 20 CU 910 AWE, ----..-.. .------- N/A CU #10 AWG ---...--- ----- --- CU #10 AWG CO #10 AWG ---- CU #10 AWE, 35 --- 35 PASS 35 - ..-- 35 2 --.....--------- 2 40 40 0.96 ........ 0.96 1 _._..-._....-------- 1 39.4 38.4 't,S:S A,SS 5 5 1?4 1,24 0,083 0 0S3 3/4" EAAT - -- - 3f4" EMT TRANSFER SWITCH BACKUP PANEL 240 37,75 47,225 so CU #8 AWG CU #10 AWG CU #9 AWE, 50 PASS 35 2 55 0.96 1 52.5 PASS 5 0.778 0, 12 2 TRANSFER SWITCH AC DISCONNECT 240 37.78 47.225 50 CU #8 AVVG CU #10 AWG CU #8 AWG 50 AS' 35 2 55 0.96 1 52.8 'A';c 5 0,778 0.122 3/4" EMT AC DISCONNECT POI 240 37.78 47,225 50 CU #8 XWG i CU #10 A>NY CU #8 AfiIG 50 PAP: 1 35 2 S5 0.96 1 52.8 E 1 0,778 0,122 3/4' EMT ENCHARGEINSTALLATION NOTES: BATTERY/ENPOWER MOUNTINGNOTES: TEMPERATURE1. THERE MUST BE NO HIGHLY FLAMMABLE OR EXPLOSIVE MATERIALS NEARBY. 2. THE AMBIENT i D BE WITHIN THE RANGE 1 THE ENCHARGE/ENPOWER HOUSING IS NEMA TYPE 3R AND CAN BE INSTALLED INDOORS OR OUTDOORS. TI HE TERMINAL BLOCKS ACCEPTS COPPER CONDUCTORS OFF NO. 12 - 8 AWG. 4. MAINTAIN AT LEAST THREE FEET OF CLEARANCE IN FRONT OF EACH PRODUCT. ALLOW AT LEAST 15CM (SIX INCHES) CLEARANCE ON TOP AND BOTTOM OF THE PRODUCT SO THAT THE VENTS ON THE TOP AND BOTTOM OF THE UNITS ARE • i FOR a • CIRCULATION. TO TWO ENCHARGE 10 (ORCAN ACHAINED D ON ONE #' INSTALLATIONSa :*:SEPARATE LOAD CENTER, SUBPANEL, OR CIRCUIT COMBINER WITH OVER CURRENT PROTECTION TO COMBINE THE DAISY CHAINED CIRCUITS, AND YOU MUST RUN ONLY ONE CIRCUIT FOR ALL THE ENCHARGE UNITS TO THE ENPOWER (OR TO ENPHASE IQ COMBINER O. GRID -TIED -ONLY a AC DISCONNECT INSTALL NOTES: 1. INSTALL AN AC DISCONNECT THAT CAN BREAK THE MAXIMUM RATED CURRENT OF THE BRANCH CIRCUIT UNDER LOAD_ THE AC DISCONNECT MUST BE INSTALLED IN LINE -OF -SIGHT OF ENCHARGE, PER NEC 2017 700.7(A'), 2, EACH ENCHARGE UNIT IS SUITABLE. FOR USE Wffld UP TO NO, 3 AWG WIRES CAN A MAXIMUM 40 A BRANCH CIRCUIT. IF MORE THAN 32 A OF ENCHARGE BATTERIES (CORRESPONDING TO A 40 A BRANCH CIR'CI IT} ARE INSTALLED, A SEPARATE SUBPANEL UST BE INSTALLED BETWEEN THE. ENCHARGE UNITS AND ENPO ER TO COMBINE THE ENPOWER CIRCUITS TOGETHER. ALL CIRCUIT BREAKERS IN THE SUBPANEL MUST BE SUITABLE FOR BACK -FEEDING, PER NEC 403.36(D, 3. VERIFY THAT AC VOLTAGE AT THE SITE IS WITHIN RANGE: SINGLE-PHASE Li TO L2 VOLTAGE MUST MEASURE BETWEEN 211 AND 264 VAC, WHILE L-N SHOULD MEASURE BETWEEN 106 AND 132 VAC. RECOMMENDED: 1. THE BUILDING SHOULD BE DESIGNED TO WITHSTAND EARTHQUAKES. 2. THE WATERPROOF AND PROPERLY VENTILATED AREA IS RECOMMENDED. (IP55) 3. INSTALL THE PRODUCT OUT OF REACH OF CHILDREN AND ANIMALS. Ckcu@t 1 Vrrltage Drop 1.509 Circuit 2 Vafitage Drop L 1.579 ALL # BY UL OR OTHER NRTL, ♦ if LABELED FOR ITS APPLICATION. COMPLY2. ALL CONDUCTORS SHALL BE COPPER, RATED FOR 600 V AND 90 DEGREE C WET ENVIRONMENT. 3. WIRING, CONDUIT, AND RACEWAYS MOUNTED ON ROOFTOPS SHALL BE ROUTED DIRECTLY TO, AND LOCATED AS CLOSE AS POSSIBLE TO THE NEAREST RIDGE, HIP, OR VALLEY. 4. WORKING CLEARANCES AROUND ALL NEW AND EXISTING ELECTRICAL EQUIPMENT SHALL f • 5. DRAWINGS INDICATE THE GENERAL ARRANGEMENT OF SYSTEMS. CONTRACTOR SHALL FURNISH ALL NECESSARY OUTLETS, SUPPORTS, FITTINGS AND ACCESSORIES TO FULFILL APPLICABLE CODESAND STANDARDS. WHERE6. OF • . . CONDUITS ARE NOT I, CONTRACTOR SHALL SIZE THEM AC•-Ir ALL x '#NS SHALL BE APPROPRIATELY a r iA! READILY DI i. MODULE GROUNDINGPS • BE aLLED BETWEEN MODULE FRAME AND MODULE SUPPORT RAIL, PER THE GROUNDING CLIP MANUFACTURER'S INSTRUCTION. 9. MODULE SUPPORT RAIL TO BE BONDED TO CONTINUOUS COPPER G.E.C. VIA WEEB LUG OR ILSCO a#:LAY-IN 10. THE POLARITY OF THE GROUNDED CONDUCTORS IS NEGATIVE. 11. TEMPERATURE RATINGS OF ALL CONDUCTORS,TERMINATIONS,a . OTHER DEVICES ASSOCIATED WITH THE SOLAR PV SYSTEM SHALL BE RATED FOR AT LEAST 75 DEGREE C. �' X .: = LU LUNEX POWER INC. 4721 N GRADY AVE TAMPA FL 33614 LIC ##: CVC57085 PHONE: 813-540-8807 REVISIONS DESCRIPTION DATE REV s' / DATE: 05/31 /2023 PROJECT NAME & ADDRESS >- N Q � co UJ Z J co z J � � W C J � w C/) 0 N LU N iO ®- DRAWN BY ESR SHEET NAME WIRING CALCULATIONS SHEET SIZE ANSI S 11" X 17" SHEET NUMBER PV-7 LABEL-1: LABEL LOCATION: AC DISCONNECT ELECTRICAL SHOCK HAZARD TERMINALS ON THE LINE AND LOAD SIDES MAY-' BE ENERGIZED IN THE OPEN POSITION LABEL- 2: I ARFI I nr.ATInN- AU UIbkUNNtt_ I COMBINER MAIN SERVICE PANEL SUBPANEL MAIN SERVICE DISCONNECT CODE REF: NEC 690.13(B) LABEL- 3: LABEL LOCATION: PRODUCTION METER UTILITY METER MAIN SERVICE PANEL SUBPANEL CODE REF: NEC 705.12(C) & NEC 690.59 LABEL- 4: 1 ARFI I 0(',AT[nN- MAIN SERVICE PANEL SUBPANEL MAIN SERVICE DISCONNECT COMBINER CODE REF: NEC 110.27(C) & OSHA 1910.145 (f) (7) LABEL- 5: LABEL LOCATION: MAIN SERVICE PANEL (ONLY IF SOLAR IS BACK -FED) SUBPANEL (ONLY IF SOLAR IS BACK -FED) CODE FIER NEC 705.12(D) & NEC 690.59 POWER SOURCE OUTPU CONNECTION. DO NOT RELOCATE THIS OVERCURRENT DEVICE LABEL- 6: LABEL LOCATION: MAIN SERVICE PANEL (ONLY IF SOLAR IS BACK -FED) SUBPANEL (ONLY IF SOLAR IS BACK -FED) CODE REF: NEC 705A2(B)(3)(2) vvi I I I f_\l_x7_lL.1 Q"tiJ I LJ%JVVI,4 TURN RAPID SHUTDOWN SWITCH TO THE "OFF" POSITION TO SOLAR ELECTRIC SHUT DOWN PV SYSTEM QPVP.ANELS AND REDUCE SHOCK HAZARD IN THE ARRAY I LABEL- 7: LABEL LOCATION: AC DISCONNECT CODE REF: IFC 605.11.3.1(1) & NEC 690.56(C) LABEL- 10: LABEL LOCATION: MAIN SERVICE PANEL SUBPANEL AC DISCONNECT CODE REF: NEC 690.54 LABEL- 11: LABEL LOCATION: MAIN SERVICE DISCONNECT (ONLY IF MAIN SERVICE DISCONNECT IS PRESENT) CODE REF: NEC 690-13(B) LABEL- 12: LABEL LOCATION: PRODUCTION METER (ONLY IF PRODUCTION METER IS USED) LABEL-13: LABEL-14: LABEL LOCATION: EMT/CONDUIT RACEWAY SOLADECK/JUNCTION BOX CODE REF: NEC 690.31 (D) (14) THE LABEL SHALL BE REFLECTIVE, WITH ALL LETTERS CAPITALIZED AND HAVING A MINIMUM HEIGHT OF 3/8 IN. (9.5 MM), IN WHITE ON A RED BACKGROUND. LABEL- 15: LABEL LOCATION: AC DISCONNECT CODE REF: NFPA 1 (11.12.2.1.1.1.1) 1, THE RAPID SHUTDOWN LABEL SHALL BE LOCATED ON OR NO MORE THAN 3 FT (I M) FROM THE SERVICE DISCONNECTING MEANS L (HEIGHT OF LABEL IS 3/8 IN. (9S MM), IN WHITE ON A RED BACKGROUND) MAIN SERVICE PANEL SUBPANEL AC DISCONNECT CODE REF: NEC 690.54 AC DISCONNECT 3 OF 3 LABEL- 16: LABEL LOCATION: MAIN SERVICE PANEL SUBPANEL AC DISCONNECT CODE REF: NEC 690.54 LABEL- 17: LABEL LOCATION: ESS DISCONNECT CODE REF: NEC 706.15(C) LJLAJ_, Ak LUNEX POWER INC. 4721 N GRADY AVE TAMPA FL 33614 LIC #: CVC57085 PHONE: 813-540-8807 REVISIONS DESCRIPTION DATE REV DATE: 05/31/2023 PROJECT NAME & ADDRESS L0 m z cy) z _j Z LL uj rn -J T < uj U- co 00 04 LL] Cr:) N DRAWN BY ESR SHEET NAME LABELS SHEET SIZE ANSI B 11 " X 17" SHEET NUMBER PV-8 a • l f (N) AC DISCONNE BA. ■ LOAD P IE ENPHASE R TRANSFER ♦ DISCONN +COMBINER] (N) ESS AC DISC (N) 1-ENPHASE sR r . � � �� �� � . #• psi' � i . �' • •iTj to] a 111110MV-01 ki 1011 IN I 10 KIM I W—Al killbvidilkiroll lr#lkvltol, PLAQUES AND BE i OUTLINED NEC .•i ! LABELING NOTES: FIELDREQUIREMENTS IN THE PER CURRENT NEC AND LOCAL CODES• D MAKE APPROPRIATE ADJUSTMENTS. LABELING2. 11 BASED ON THE 2017 NATIONALOD OSHA STANDARD MATERIAL BASED ON THE REQUIREMENTS 4. LABELS TO BE OF DURABILITY TO WITHSTAND THE ENVIRONMENT INVOLVED 5. LABELS O BON RED BACKGROUND; AND PERMANENT LLJ ;Dow. LUNEX POWER INC. 4721 N GRADY AVE TAMPA FL 33614 LIC #: CVC57085 PHONE: 813-540-8807 REVISIONS DESCRIPTION DATE REV i I I f DATE: 05/31 /2023 PROJECT NAME & ADDRESS < d" UJ C 7 Z LLI PP)� 1 S..J Z LL >- J J Cn Lu J U) m J }' W = u- U) 00 N LLI o DRAWN BY ESR SHEET NAME PLACARD SHEET SIZE ANSIpp 11" X 17" SHEET NUMBER f- V -9 z� S(XAR so=l NAM H?��74E 10A, LUN=m POWEER ~oyLUNEXP01WIER,Com )VADEIN far LUNEX POWER INC 4721 N GRADY AVE TAMPA F L 33614 HIGH CONVERSION EFFICIENCY Pao dine effic ency up to 211,0% EXCELLENT WEAK LIGHT PERFORMANCE Marc po-wev out'put in Nepk qoht S \0010 conr'kt:or, such, a,, cloudy days, momms mor-mno and sunset EXTENDED MECHANICAL PERFORMANCE Mod-'u'�C- ceufiPd' lo,,fthstand PA ' (2400 Pa) and extreme e�n (�7;—47111 , L-t- Ei;Dow-t1a LUNEX POWER INC. 4721 N GRADY AVE TAMPA FL 33614 LIC #- CVC57085 PHONE: 813-540-8807 REVISIONS DESCRIPTION DATE REV DATE: 05/31/2023 PROJECT NAME & ADDRESS >: < w c") Z LU C6 fn U) -J LIJ < w z: LL c/) 00 04 LLI N DRAWN BY ER SHEET NAME EQUIPMENT SPECIFICATION SHEET SIZE ANSI B 11" X 17" SHEET NUMBER Pv-1 1 PENPHASE Our newest lQ8 Microinverters are the industry's first microgrid-form Ing, software - defined Inicroinverters with split -phase Dower conversion capability to Convert DO power to AC power efficiently- The brain of the serni Conductor- based microinverter is our proprietary application -specific integrated circuit (ASIC) which enables the microiriverter to operate in grid -tied or off -grid modes. This chip is built in advanced 55inm technology with high speed digital logic and has suiper-fast response times to changing loads and grid events, alleviating constraints on battery sizing for home energy systems- oio Part of the Erphaw Energy System, 108 Series t08 Series MicrciiirvwlerF redebime feflabilltv Mcrariverters mrsarzteatth ihe Entoase iQ Batteiystandards wiliti w-re, tFuu, one Pralhon curnrufaove Enlxhaf,x= KI Cat eway, and lo, Enprawt, Ares rrionimiring hours of pasme-on testing, enatoing arl 1-austy- ar,,j analysis soltardre vading limTed ea rand r4 up to 25 oear^x. Co-,nect PV maJules quiciitv ina east to 108 Seriss lQ8 Series Mcroirfvsrnos are Listeoas k4criAnveriersueng Tte, inclusind, O-DCC-2 adaptor PV Roost Shut Down Ecuprient 3nd ccnfo"r with crliovathpag, n-rlay1dC4r*Drnect,,xs. various ritaniffacturer's irtatrurtiona, Easy to install Lightwei cft)t and compact with plug-n-ploy connectors Power Line Communication (;ILC) between components Faster installation with simple trio -wire Cabling High productivity and reliability produce power even when the grid is down.* More than one million Cumulative hours of testing Class 11 double -insulated enclosure Optimized for the latest high- powered PV modules MEMEM811= Complies with the latest advar-ced grid support — Remote automatic updates for the latest grid requirements Configurabie to support a wide range of grid profiles Meets CA Rule 21 (UL 1741-SA) requirements Cornmairy used M—dulepainngs" W Module comparL41ty 235-350 60-cell/120hafl-ceR 2,15-440 60-c,elt/120ha[f-cex1,°56-c,eft/132Fiair :fill ar,d72-cpil/144 half -el MPPT vartagerarige, 27--37 29-45 ora,ratirai oi,­,g, v 25-48 25-58 tsin/rnax start voltage 30/48 30/58 N!axnput DC. voftsoe- s 50 60 Max DC current" ,modwers6i A 15 0,avoftacs- class Dc port, 9 DC port baelifeedovieint rA 0 PV affay corlf,,gmatkin W Urigrourid-darrav ede notaotion requires max 2tw M bratico wcu,'t Peak Output Passe, VA 245 300 Max caninutaus outran; Power va 240 29 Nominxif (L-L }vlxltage/rssuiars 2140 211-- 264 Max Continuous Output currant A to L21 Norninaffrequairoo llz 60 Extended frectueniov range ttz 50-68 AC: short -ircurt fault current over 3 aycks Au-m 2 Wx unitsiser, 20 A (L-L) brary h circ ult{ l6 113 Tots I rar, mnic disto-sce, 5%, Ocaevaftaxp, class AC ;oxt W AC Port backfeed current sA 30 Power factor orting 1,0 Gran -tied passer factor (adjustable) C85 leading - 0.85 lagging Peak efficiency % 975 976 CEC weighted effirliancy % 97 97 Nigm-tfrne nower, consurristion tuff 60 ArTbert nsirtserature ninise -40'C to 450cC (-40"F to l40"F) Rtearivc hunr6ty rarose Ale To 100c (condensing) DC Corxr�tor ty MC,4 Dimer,sions fHx%tvxD) inmr1,21 weigf-a t08 kg (2,38 ito) Cn,lir-4 NinIra, coroecbor, - ra1 fans Apprvie", foraet liscelorss xes poluscirldegies PD3 Eq,-' osure Class it dioulas - maiA sped, cor rostan res isrant p* ar to lov, loatre Ermrori c-ategory / UN exposure naing NEMA Ts;ro 6 / ouidocir CA Rule 22 (UL V41 -SA), UL 82109- I, U U74m EEE154 7, FCC Part 15 Class B. tCES-0003 Uses B. CA N/C SA-C22.2 NQ 1071-01 (olf,fis,anoxia This. product is UL Listed as PV Papid Shut Down Equilarnrnit and conforms with NEC,204, NEC 2017. a r4 NEC 2020 section 690,12 and C22,1- 2018 Rue, 64 -2118 Papki Shuta own of PV Systems, for AC and DC cond, ir-to; a, wr",- , insta fled moardi"S to D 2022 Eriptoss, Energy-M r rghts reserves. E nprose, th, Eriphase logo, fQ8 Microirrvpr ters. andathear 'OnIvathen !Q Svoneo Corsnalier 2. Manufacturer's atsnuotsons. rorn�,r Pre tracierriarks, a-,' Fnptla&_-_ EM-Fgy, fnCr Data subleor to charge r, o et s UL 1 -74 ril, No DC/AC ralro. Sea the conipa.bility calcularp, at KNiand n8faus suppoos split phase, w0V (21 Maximum continuous, lnstut DC_ currere is 10,6A (3) riori anal vorage, range can be Pxtemded loxxtrea-i• rronroi if required V28SP-DS-0002-CII-EN-US-2C.22-03-',7 nt "tiartlow Cray by theutflity (4) UmOsmaywry. R,,f'-1 to local requirpmenns to define the number of mr-roiliverhas per twench tri cour atea- _,E�, sly. We LUNEX POWER INC. 4721 N GRADY AVE TAMPA FL 33614 LIC #: CVC57085 PHONE: 813-540-8807 REVISIONS DESCRIPTION DATE REV DATE: 05/31/2023 PROJECT NAME & ADDRESS < L0 CY) Z CY) W Z z >_ LL W _j cli U) LU < LLJ = 7- 00 CL LIJ N C) IN DRAWN BY ESR SHEET NAME EQUIPMENT SPECIFICATION SHEET SIZE ANSI B 11 " X 17" SHEET NUMBER PV-12 rj I "OMI-inar AIAI --- X-1Q-AM1-240-4 X-1Q-AM1-240-4C Owned �eA oct� ef"""o G�j, r p;k- ba, C 0' iA pog r boons my 'Wrom FAjaN, NO ucu,ned NEM21 ype 34 enon ox-,- Ave Ww Nuld wommy �,%fi yevrs oz'. te�� reN-ro-,��sse� �,Pf "ohdau 1w n0i te Q Con; & w; SKU �z ul 41ed L04tU To, Enphase afknrgs, rsn enphasmonm Enphase IQ Combiner 4/4C MODEL NUMBER 0 C=NM 4 NWAWAW4QCman, 4 mm RWme 0 Gale,,at-1,NSi AU ""a aw 1 won 1m; woo nmx" a, own so 0 %um4wowl VO 5 400 M" ACCESSORIES AND REPLACEMENT PARTS sepuately� C0,0111MIS klll. 36 Enwmbk mms M I M at A M 0W, - P 10 5 V baned L a W1 WOM mamm w" 5 vew 8,M dw can, 005ME&MI a AT 05 4G Ond UK M! WVw malem wW 5 pw A MT AU Wan, I", " !qpwvFnnnRRA3 3M48KM MIT BOA ASO mRNU �nmw,ow, AN GA 2 ATj smw 5"My 2 me ?w Fw" !�, XIMA ELECTRICAL SPECTMATiONS 07 no gn 2; A pu W M6 A qW wm umm! wmWmm, MECHANICAL DATA Dw"n= ww= NO psi TOWEN 77"" Whim K"N "k,, I&V rNTERNE T CONNECTION OPTIONS LUNEX POWER INC. 4721 N GRADY AVE TAMPA FL 33614 LIC #: CVC57085 PHONE: 813-540-8807 REVISIONS DESCRIPTION DATE REV DATE: 05/31/2023 PROJECT NAME & ADDRESS >- C14 < -q 3: 1 CIO LLJ Z LLJ z Ell C) co U) LU < W -r u— 0f C/) 00 CL N UJ Cr:) N DRAWN BY E S FR SHEET NAME EQUIPMENT SPECIFICATION SHEET SEE ANSI B 11" X 17" SHEET NUMBER PV-13 Enphase Enpower S I r d vd umnpoA �o4f u, d p" i .,a. k, j Up o r, iin � , ,,.9 �iq)pocl Enphase Enpower MODEL NUMBER ;"'J!0 V) ACCESSORIES 8nd REPLACEMENT PARTS ui8a,. K:Bq'— 't, �-dr,. h, A",", od 1,0r, N', NW p, lk A, :4 A I i 1 N N Vl h�,K kl ELECTPsCAL SPECiFICAT'ICNS h W rXI-1- N� cl 1— ik j W&, .. 2 MECHlANICAL DATA 4 ie�ll k" M ENPHASE. ENPHASE. LLINEX POWER INC. 4721 N GRADY AVE TAMPA FL 33614 LIC #: CVC57085 PHONE: 813-540-8807 REVISIONS DESCRIPTION DATE REV DATE: 05/31/2023 PROJECT NAME & ADDRESS >: cj U-) (y) z W (.) z Z >- LLJ cli co U) LIJ—j < W T— LL c/) oc) CL N LLJ 0 DRAWN BY ESR SHEET NAME EQUIPMENT SPECIFICATION SHEET SIZE ANSI B 11" X 17" SHEET NUMBER PV-14 Enpilhase Rekah yea" v abT u—t—KIw ENPHASE, Enphase Encharge 10 MODEL NUMBER KiF End rge, '&o�ag, ystel,, m'h milef, a t e d o i, c efter� 'and, One Eqch, o,,er kll mth, cove�, wad rm-juroung brw�,evvateMqht cordult anc� OUTPUT AC) 240 VAC' Rate'd t5, 'u'u'A"eF, 3 34 kVA BATTERY Rxwum,J, trp efncy maxolnllum, ur- vcftaq,-, 0 �'V'ECHAtflCAL DATA 4 N'- ?,41A 0 e ouen"g, V',,,�t g!-MLas te g, ENPHASE. U N LUNEX POWER INC. 4721 N GRADY AVE TAMPA FL 33614 LIC #- CVC57085 PHONE: 813-540-8807 REVISIONS DESCRIPTION DATE REV DATE: 05/31/2023 PROJECT NAME & ADDRESS < u') c) LIJ z cy) W (-) z _j Z LL LLJ cli 00 LLJ M LL 0 00 LJJ N DRAWN BY ESR SHEET NAME EQUIPMENT SPECIFICATION SHEET SIZE ANSI B 11" X 17" SHEET NUMBER PV-1 5 19 C'rossRall Systenn 12 13 10 14 Larg SoatD145,116 x 4' SS S M: o` a F CrossRail 80 168" Ra",,, hilliti &,nsRai� 4P-XL 66, fAHH or Dark 48 X/418 X'_ C,,,c,,,asRaH 4FX 166" of 180', hxlii� o, D,,-)-k CrcrrsRa;� 44-X 166", Mib or Dxark Cc-rsR,­ 44 X E,d Caul CR Mid Oamun 5Rver o, Dark I 40003�, z10,IX,,(),_8 14000-6,95, 40,0Q705 fuG, 4 31, 140,00662, 4000675, 4(31310063 MN013019, 40( 020 4000*60 � -H, ARXX,6402 4- 14 ti, C I a m p 4,11-4 i d d e n En d C I a r-rf p) 4 0-1-a 0, 000 5 0 - i -It (3rosr.--),F-)-,alj LILI-X Mechanical Proper -Lies MaterW Ult ma-te Tensilo Strength, YWd Strenuth 'Y'Ve i g ha 9"nish Section Proper -Lies 00 0 S A', 37,7 ksi (260 NlPal '240 r-,APa, 0_47 ;bslft kghn) M o r "a Sy Sy 0.1450 ml,"0,368,3 w3l) A (X-Section) Dimensions in [mm] Inches UL2703 CislSyslern for hfand Bordig j j v 6—ull4m A LUNEX POWER INC. 4721 N GRADY AVE TAMPA FL 33614 LIC #: CVC57085 PHONE: 813-540-8807 REVISIONS DESCRIPTION DATE REV DATE: 05/31/2023 PROJECT NAME & ADDRESS >: Cj < L0 CY) z (y) w z _j Z >_ LL _j cli M < w 7- LL 00 C14 UJ CrD N DRAWN BY ESR SHEET NAME EQUIPMENT SPECIFICATION SHEET SIZE ANSI B 11 " X 17" SHEET NUMBER PV-16 We support PV systems Formerly Everest Solar Systems^ Splice Foot XL Patent Pending 1 Splice Foot. XL N 3 N115 x 60 lag screws T-Bolt & Hex Nut Set Technical Data Roof Type Mat chill L4000162 I Splice Foat XL 0, Mill Composition shingle Aluminum with stainless steel hardware Finish Mill Roof Connection i M5 x 60 lag screws Code Compliance I UL 2703 Compabbifity ass ail 44-X, 48- 0 N We support PV systems Formerly Everest Solar Systems 0� a 0 0 N L.UN=-X POWEI-pt LUNEX POWER INC. 4721 N GRADY AVE TAMPA FL 33614 LIC #: CVC57085 PHONE: 813-540-8807 REVISIONS DESCRIPTION DATE REV DATE: 05/31/2023 PROJECT NAME & ADDRESS >� N < 1- CY) W z CY) W () 7 —1 Z 111- Uj cli rn U) -j LU < TZ LL U) 00 04 Uj CrD N DRAWN BY ESR SHEET NAME EQUIPMENT SPECIFICATION SHEET SIZE ANSI B 11 " X 17" SHEET NUMBER Pal-17 ---------- .1• 4004, 1101� * Stamped Seamless Construction * 18 Gauge Galvanized Steel * Powder Coated Surfaces * Flashes into the roof deck "I l"W"MMMMAM fittings or conduit 2 Position Ground lug installed Mounting Hardware Included I "Fuse holders and terminal bhocks added ai the field must be UIL listed of recognized and rneet 600 VD' 30 AMP 11 OC for fuse holders, 600V 50 AMP 90C for rail mounted terminal blecks and 600 V 175 AMP 90C for Power Distnbution Blocks- Use Copper Vfire Conductors SoIaDerk Model SD 0783 !11111111!10 711�illillilillilli Available Models: Model SD 0783 - (3- fixed Din Rail) Model SD 07 86 - (6' slotted Din Rail) Models SD 0783-41 and SD 0786-41 are labeled and ET?. listed UL STD 1741 according *a the UL STD 1741 for photovoltaic cornbirter enclosures, Max Rated - 60OVDC, 120AMPS Model SO 0783-41 3" Fixed Din Rail fastened using Norlock System **Typical System Configuration 4- Din Rail Mounted Fuse Holders 60OVDC 30 AMP I - Power Distribution Block 60OVDC 175AMP 1- Bus Bar with UL lug Model SO 0786-41 6" Slotted Din Rail fastened using steel studs **Typical System Configuration 4- Din Rail Mounted Fuse Holders 60OVDC 30 AMP 4- Din Rail Mounted Terminal Blocks Bus Bars with UL lug condo or fittings base gs center riIted for filting locations Medal SO 0783-41 . wired w0h Model SD 0786-41, wired with Din Rail mounted fise holders, Din Rail mounted fuse holders bus bar and power distnbubon terminal blocks and bus bars, Mock, RS TC Enterprises, Inc - 2219 Heirnstead Road . Eau Cliare, W1 54 703 For product information call 1(866) 367-7782 LUNEX POWER INC. 4721 N GRADY AVE TAMPA FL 33614 LIC #: CVC57085 PHONE: 813-540-8807 REVISIONS DESCRIPTION DATE REV DATE: 05/31/2023 PROJECT NAME & ADDRESS >: < L0 M W Z CY) W Z _j C0 >- u- -.1 LLJ —j (6 3: g >- _j 00 U) W—j < W r U— O—e (11) 00 CL C14 LU CrD N DRAWN BY ESR SHEET NAME EQUIPMENT SPECIFICATION SHEET SIZE ANSI B 11" X 17" SHEET NUMBER PV-18 =xrfW -1 LUNEX POWER INC. 4721 N GRADY AVE TAMPA FL 33614 LIC : CVC57085 PHONE: 813-540-8807 REVISIONS DESCRIPTION DATE REV DATE: 05/31 /2023 PROJECT NAME & ADDRESS >- CV Q d' LLJ cn Z J u- j } J m LLJ _ Ili = Li_ (o _ 00 IZ C®i W 1 V-11' LIaCVIfiVlisltli V1-L4..1116..rt111VIdV CODE REFERENCES DRAWN BY ESR 16. DISCONNECTING MEANS SHALL BE LOCATED IN A VISIBLE, READILY ACCESSIBLE LOCATION WITHIN THE PV SYSTEM EQUIPMENT OR A MAXIMUM OF 10 FEET AWAY FROM THE SYSTEM [NEC 690.13(A)] PROFESSIONAL ENGINEER SEAL PROJECT TO COMPLY WITH THE FOLLOWING: 19. ALL WIRING METHODS SHALL BE IN ACCORDANCE WITH NEC 690.31 FLORIDA RESIDENTIAL CODE, 7TH EDITION 2020 (FRG) SHEET NAME 20. WORK CLEARANCES AROUND ELECTRICAL EQUIPMENT WILL BE MAINTAINED PER NEC 110.26(A)(1), 110.26(A)(2) AND 110.26(A)(3). 21. ROOFTOP MOUNTED PHOTOVOLTAIC PANELS AND MODULES SHALL BE TESTED, LISTED & IDENTIFIED IN ACCORDANCE WITH UL1703 FLORIDA PLUMBING CODE, 7TH EDITION 2020 (FPC) FLORIDA BUILDING CODE, 7TH EDITION 2020 EDITION (FBC) FLORIDA MECHANICAL CODE, 7TH EDITION 2020 (FMC) 2017 NATIONAL ELECTRICAL CODE COVER SHEET SHEET SIZE 22. ELECTRICAL CONTRACTOR TO PROVIDE CONDUIT EXPANSION JOINTS AND ANCHOR CONDUIT RUNS AS REQUIRED PER NEC. FLORIDA FIRE PREVENTION CODE, 7TH EDITION (FFPC) ANSI 23. THE ENCHARGE BATTERY AS PART OF THE ENSEMBLE SYSTEM DOES NOT EXPORT POWER TO THE GRID IN ANY STORAGE 11 " X 17" MODE, SHEET NUMBER PV-1 NUMBER OF MODULES = 18 MODULES MODULE TYPE = HYPERION SOLAR: HY-DH108P8-400B 40OW MONO MODULES MODULE WEIGHT = 5555 LBS / 252 KG ROOF DESCRIPTION LLJN=, Y r'A LLJN=, Y r'A LUNEX POWER INC. 4721 N GRADY AVE TAMPA FL 33614 LIC #: CVC57085 PHONE: 813-540-8807 REVISIONS DESCRIPTION DATE REV DATE: 05/31/2023 PROJECT NAME & ADDRESS >: cj < "t �: c) W 7 (y) Z >- u- w C6 co -J U) -j T W ry >- LL Irf U) -r 00 CL C\J W N DRAWN BY ESR SHEET NAME ROOF PLAN & MODULES SHEET SIZE ANSI B 11" X 17" SHEET NUMBER PV-3 FRO K gm SEE (2/1 ENLAR( L.121f,IT 1 s • lll�11 t" LUNEX POWER INC. 4721 N GRADY AVE TAMPA FL 33614 LIC #: CVC57085 PHONE: 813-540-8807 REVISIONS DESCRIPTION DATE REV Z, DATE: 05/31 /2023 PROJECT NAME & ADDRESS UJ4M'J 4'J Z LLJ 0 60 VJ�J I tee i" c W = IllILL Cifu _ o00 DRAWN BY ESR SHEET NAME STRUCTURAL DETAIL SHEET SIZE ANSI S 11" X 17" SHEET NUMBER PV-5 DC SYSTEM SIZE: 18 x 400 = 7.200 kW DC AC SYSTEM SIZE: 18 x 290 = 5.220 kW AC (18) HYPERION SOLAR: HY-DHI08P8-400B 40OW MONO MODULES WITH (18) ENPHASE: IQ8PLUS-72-2-US (240V) MICROINVERTERS (COMPLIANT WITH RAPID SHUTDOWN) 1(2) BRANCH CIRCUITS OF 9 MODULES ARE CONNECTED IN PARALLEL ENPHASE IQ-SYSTEM-CONTROLLER-2 NOTE: THE ENPHASE IQ -SYSTEM CONTROLLER 2 CONNECTS THE HOME TO GRID POWER, THE ENCHARGE STORAGE SYSTEM, AND SOLAR PV. IT PROVIDES MICROGRID INTERCONNECTION DEVICE (MID) FUNCTIONALITY BY AUTOMATICALLY DETECTING AND SEAMLESSLY TRANSITIONING THE HOME ENERGY SYSTEM FROM GRID POWER TO BACKUP POWER IN THE EVENT OF A GRID FAILURE. IT CONSOLIDATES INTERCONNECTION EQUIPMENT INTO A SINGLE ENCLOSURE AND STREAMLINES GRID INDEPENDENT CAPABILITIES OF PV AND STORAGE INSTALLATIONS BY PROVIDING A CONSISTENT, PRE -WIRED SOLUTION FOR RESIDENTIAL APPLICATIONS. (18) HYPERION SOLAR: HY-DHI08P84006 40OW MODULES BRANCH:I 1 2 0 0 + + + 0 BRANCH #2 SOLADECK, 600V NEMA R, UL LISTED + 3 1 0 0 0 0 BRANCH ------- 0 TERMINATOR L (ET -TERM) (18)ENPHASE 108PLUS-72-2-US(24OV) MICROINVFRTERS (COMPLIANT WITH RAPID SHUTDOWN) LOCATED UNDER EACH PANEL c c c ELECTRICAL LINE DIAGRAM (7" PV-6 SCALE:NTS INTERCONNECTION NOTES: 1. INTERCONNECTION SIZING, LIMITATIONS AND COMPLIANCE DETERMINED IN ACCORDANCE WITH [NEC 705.12], AND [NEC 690.59]. 2. GROUND FAULT PROTECTION IN ACCORDANCE WITH [NEC 215.9], [NEC 230.951. 3. ALL EQUIPMENT TO BE RATED FOR BACKFEEDING. 4. PV BREAKER TO BE POSITIONED AT THE OPPOSITE END OF THE BUSBAR RELATIVE TO THE MAIN BREAKER. DISCONNECT NOTES: 1. DISCONNECTING SWITCHES SHALL BE WIRED SUCH THAT WHEN THE SWITCH IS OPENED THE CONDUCTORS REMAINING LIVE ARE CONNECTED TO THE TERMINALS MARKED "LINE SIDE" (TYPICALLY THE UPPER TERMINALS) 2. AC DISCONNECT MUST BE ACCESSIBLE TO QUALIFIED UTILITY PERSONNEL, BE LOCKABLE, AND BE A VISIBLE -BREAK SWITCH 3. DISCONNECT MEANS AND THEIR LOCATION SHALL BE IN ACCORDANCE WITH [NEC 225.311 AND [NEC 225.32]. RACKING NOTE: 1, BOND EVERY OTHER RAIL WITH #6 BARE COPPER EBB AD DISCONNECT#2 ONTROLLE 240V, I �, 3W (N) ENPHASE 30A RATED ENCHARGE-10-IP-NA A3R BATTERY ENPHASE X-IO-AM1-240-4/4C AC COMBINER BOX 1 20/240VAC, 1�, 3W 125A RATED BUS BAR, NEMA 3R SOLAR LOADS ONLY ALI UL 17411 COMPLIANT L2 PV AC DfSCONNECT#1 �44 240V, 1�, 3W — 30A RATED 01- NEMA3R GATE' -AY 17 LINE 20 2P F r--12 Ll _2 VISIBLE, LOCKABLE LABELED AC DISCONNECT Li I N I LOCATEDW THIN 0' L2 01 R UTILITYMETER Li ENPHASE SYSTEM SHUTDOWN SWITCH GROUNDING & GENERAL NOTES: 1. GROUNDING ELECTRODES AND GROUNDING ELECTRODE CONDUCTORS. ADDITIONAL GROUNDING ELECTRODES SHALL BE PERMITTED TO BE INSTALLED IN ACCORDANCE WITH 250.52 AND 250.54.GROUNDING ELECTRODES SHALL BE PERMITTED TO BE CONNECTED DIRECTLY TO THE PV MODULE FRAME(S) OR SUPPORT STRUCTURE PER [NEC 690.47(B)] 2. PV INVERTER IS UNGROUNDED, TRANSFORMER -LESS TYPE. 3. DC GEC AND AC EGC TO REMAIN UNSPLICED, OR SPLICED TO EXISTING ELECTRODE 4. ANY EXISTING WIRING INVOLVED WITH PV SYSTEM CONNECTION THAT IS FOUND TO BE INADEQUATE PER CODE SHALL BE CORRECTED PRIOR TO FINAL INSPECTION. 5. SOLADECK QUANTITIES, AND PLACEMENT SUBJECT TO CHANGE IN THE FIELD - SOLADECK DEPICTED ON ELECTRICAL DIAGRAM REPRESENT WIRE TYPE TRANSITIONS. 6. AC DISCONNECT NOTED IN EQUIPMENT SCHEDULE OPTIONAL IF OTHER AC DISCONNECTING MEANS IS LOCATED WITHIN 10'OF SERVICE DISCONNECT. 7. RACEWAYS AND CABLES EXPOSED TO SUNLIGHT ON ROOFTOPS SHOULD BE INSTALLED MORE THAN 7/8" ABOVE THE ROOF USING CONDUIT SUPPORTS. E CHECK �20%RU 20% X 200A = 240A 2178A X 1,25 = 2722A LOAD 16A X 125 = 20A TO UTILITY GRID 27-225A,20A = 47.225A 240A-175A = 65A-SOA, OKAY Ll _2 N ENPHASE IQ SYSTEM CONTROLLER2. IS EQUIPPEDW/ 2M.ita (MICRO -GRID (N) ENPHASE 10 SYSTEM ISLANDING DEVICE) - WHICH DURING LINE DEBATE MAIN LINE CONTROLLER 2 A GRID OUTAGE,WILL OPEN AND NOT BREAKER FROM 200A BI-DIRECTIONAL EP200GI01-M240US01 ALLOW BACKFEED TO THE GRID. RATED TO 175A Im M UTILITY METER NEMA SIR, 200A RATED, 240V 120/240V 1$, 3-W LINE LOAD U NEUTRAL FORMING UA XFMR AD DISCONNECT* MlD 240V, I �, 3W 60A RATED i (N) MAIN BREAKER TO EIATI NEMA3R HOUSE 240V, 175A/2P 4 (E) MAIN METER COMBO I L 200A RATED, 240V HOLD i DOWN KIT 5OA/2P LOAD SIDE INTERCONNECTION AT MAIN PANEUSUB-PANEL PER ART. 705.12 T# T, BACKFEED BREAKER QQ REF NEUTRAL ­UHNI) 2017 NEC 705.12(B)(2)(3)(b) CITY CONDUCTOR INFORMATION CONDUIT TYPE CONDUIT SIZE 4) #12AWG - Q CABLE — (Ll & L2 NO NEUTRAL} N/A NIA #6AWG - BARE COPPER IN FREE AIR (4) #10AWG- THWN-2 (LlL2) (EXTERIOR) #10/2 Rj0MEX , ( I ) #10AWG- C THWN-2 GINO IN ATTIC EMT OR LFMC IN ATTIC 3/4' (2) #10AWG - THWN-2 (Ll,L2) (1) #10AWG - THWN-2 N EMT, LFMC OR LFNC 3/4' (1) #10AWG - THWN-2 GIND (2) #10AWG- THWN-2 (L1,L2) (1) 910AWG- THWN-2 ON D E MT, LFMC OR LFNC 3/4" (2) #10AWG- THWN-2 (LI,L2) (1) #10AWG - THWN-2 N EMT, LFMC OR LFNC 3/4" (1) #10AWG- THWN-2 GIND (2) #12AWG- THWN-2 (LI,L2) (1) #12AWG- THWN-2 IN 3/4" (1) #10AWG- HWN-2GND EMT, LFMC OR LFNC (2) 48AWG - TH N-2(Ll,L2) 1 1) #8AWG - THWN-2 N EMT, LFMC OR LFNC 3/4" (1) #10AWG- THWN-2GND �l 2'1 �NG TTEE (N} MAIN BREAKER TO HOUSE 240V, 50AJ2P IN) BACKUP PANEL, I OOA RATED, 240V _LGEC EXISTING GROUNDING ELECTRODE SYSTEM TO EARTH REP. NEC 250.52, 250.53(A) OENPOWER MAIN LUG RATED FOR #1 AWG-350 KcmIL-(ALL SMALLER WIRE TERMINATIONS REQUIRED U L RING TERMINAL.) ENPOWER DRY CONTACTOR RATINGS - 12V- 24V MAX, (1A) COMMUNICATION KIT U N LUNEX POWER INC. 4721 N GRAD AVE TAMPA FL 33614 LIC #: CVC57085 PHONE.- 813-540-8807 REVISIONS DESCRIPTION DATE REV k7 DATE: 05/3112023 PROJECT NAME & ADDRESS >: cj < 't L0 co w z cy") w .) Z —i ( 00 Z w _j LIJ ct < LLJ _r >_ LL C/) -F 00 CL C14 LL) N ro DRAWN BY ESR SHEET NAME ELECTRICAL LINE DIAGRAM SHEET SIZE ANSI B 11" X 17" SHEET NUMBER PV-6 INVERTER SPECIFICATIONS MANUFACTURER / MODEL # ENPHASE: 108PLUS-72-2-US (240V) MICROINVERTERS (COMPLIANT WITH RAPID SHUTDOWN) MIN/MAX DC VOLT RATING 30V MIN/ 58V MAX MAX INPUT POWER 235W-440W NOMINAL AC VOLTAGE RATING 240V/ 211-264V MAX AC CURRENT 1.21A MAX MODULES PER CIRCUIT 13 (SINGLE PHASE) MAX OUTPUT POWER 290 VA SOLAR MODULE SPECIFICATIONS MANUFACTURER / MODEL # HYPERION SOLAR: HY-DH108P8-400B 40OW MODULE VMP 31.01V IMP 12.90A VOC 37.07V IBC 13.79A TEMP. COEFF. VOC -0.27%/°C MODULE DIMENSION 67.08"L x 44.65"W x 1.18"D (in Inch) • A AMBIENT TEMPERATURE �RECORDLOWTEMP AMBIENT TEMP (HIGH TEMP 2%) ( LPERCENT OF _VALUES NUMBER OF CURRENT CARRYING CONDUCTORS IN EMT AC CALCULATIONS CUIT ORfGIN CIRCiUT DESTINATION VOLTAGE IV) FULL LOAD AMPS "FLA" (AI FLA'S.ZS (A) OCPD SIZE (A) NEUTRAL SIZE GROUND SIZE CONDUCTOR SIZE eSaC AMPACiTY (A) AMPACITY CHECK #1 AMBIENT TEMP. (`C) TOTAL CC CONDUCTORS TORS IN RACEWAY 90°C AMPACITY (A) DERATION FACTOR FOR AMBIENT TEMPERATURE NEC 310.15(8)(2)(a) D£RATION FACTOR FOR CONDUCTORS PER RACEWAY NEC 310.15(8)(3)(a) 90'C AMPACITY DEBATED (A) AMPACITY CRECY #2 FEEDER LENGTH (FEET) CONDUCTOR &rOLTAGE RESISTANCE DROP AT (i3HM/KFf) F ({� CONDUIT SIZE CONDUIT FILL (l) CIRCUIT 1 SOLADECK 240 10,89 13.6125 20 N/A BARE COPPER #6 AWG CU #12 AWG 25 PAS_. 35 2 30 0.36 1 29.8 PASS 0.310 NAN CIRCUIT 2 SOLADECK 240 10,89 13.61.25 20 N/A BARE COPPER #6 AWG CU #12 AWG 25 PASS 35 2 30 0.96 1 28.E P111,11111 0.380 N/A SOLADECK COMBINER BOX 240 1089 116125 20 N/A CU #10 AWG CU #1€3AWG 35 PASS 35 4 40 0.96 0.8 30.72 PASS 34 1.24 0.729 3/4" Et>4T COMBINER BOX AC DISCONNECT 240 21.78 27.225 30 CU #10 AWG CU #10 AWG CU #10 AWG 35 PASS, 35 2 40 0.96 1 1 1 38.4 PASS S 1,24 0.113 3/4" EMT AC DISCONNECT TRANSFER SWITCH 24G 2178 27.225 30 CU #10 AVJG CU #10 A%,IJG Cu ##10 AWG 35 PASS 35 2 40 096 I 38.4 5 2.24 0.113 3/4" EMT TRANSFER SWITCH BATTERY AC DISCONNECTBATTERY BATTERY AC DISCONNECT 240 240 16 16 20 20 20 20 CU #I0 AWG N/A CU #10 AWG CU #10 AWG CU #IOAWG CU #1€S AWG 35 35 :,, >'* PA' s 35 35 2 Z 40 400.96 0.96 1 1 38.4PAI,S: 38.4 PA�,S 5 S 1,24 0.083 1,24 0,083 3j4" EMT 3%4" EMT " TRANSFER SWITCH BACKUP PANEL 240 37.78 47.22'5 50 CU #8 AWG CU #10 AWG CU #8 AWG 50 AsS 35 2 55 0.96 1 52.8 > 5 0,778 0,122 3J4" EMT TRANSFER SWITCH AC DISCONNECT 240 37.78 47.225 so CU #8 AWG CU #10 AVID CU #8 AWG 50 PASS 35 2 SS 0.96 1 52.8 ='/��;`; 5 0.778 C3.i22 3j4" EMT .' ..'. AC MSCONNECT POI 240 37.18 47,2251 50 CU #8 AWG CU #I'J A'WG CU #8 AWG so 35 2 55 0.96 I 52.8 S 0,778 0.122 3/4` EMT INSTALLATIONENCH}• i♦. •O THEREWER MOUNTING NOTES: ♦ a OR.. EXPLOSIVE ♦ • ♦NEARBY. 2. THE AMBIENT TEMPERATURE SHOULD BE WITHIN THE RANGE OF 5 - 131-F (-15 - 55-C) 3. THE ENCHARGE/ENPOWER HOUSING IS NEMA TYPE 3R AND CAN BE INSTALLED INDOORS OR OUTDOORS. -1 Hi= TERMINAL BLOCKS ACCEPTS COPPER CONDUCTORS OF NO, 12 - 8 AA/G. A MAINTAIN AT a O, CLEARANCERO OF EACHPRODUCT.ALLOW AT A INCHES) CLEARANCE ON TOP AND BOTTOM OF THE PRODUCT SO THAT THE VENTS ON THE TOP AND BOTTOM OF THE UNITS ARE NOT BLOCKED FOR AIR CIRCULATION. 5. UP TO TWO ENCHARGE 10 (OR SIX ENCHARGE 3) UNITS CAN BE DAISY CHAINED ON ONE CIRCUIT, FOR INSTALLATIONS WITH MORETHAN i OF UNITS, THERE MUST BE ♦ SEPARATE LOAD .•A OR CIRCUIT COMBINER WITH OVER CURRENT PROTECTION TO COMBINE THE DAISY CHAINED CIRCUITS, AND YOU MUST RUN ONLY ONE • ALL THE ENCHARGE UNITS TO THE ENPOWERO" TO ENPHASE IQ COMBINER FOR GRID -TIED -ONLY INSa ♦ • AC DISCONNECT INSTALL NOTES: 1 INSTALL AN AC DISCONNECT THAT CAN BREAK THE MAXIMUM RATED CURRENT OF 1"HE BRANCH CIRCUIT UNDER LOAD. THE AC DISCONNECT MUST BE INS IALLED IN LINE -OF -SIGHT OF ENCHARGE, PER NEC 2017 70 ,7(.A). 2� EACH ENCHARGE UNIT IS SUITABLE FOR USE WITH P TO NO, 8 WAG WIRES ON A MAXIMUM 40 A BRANCH CIRCUIT, IF MORE THAN 32 A OF ENCHARGE BATTERIES (CORRESPONDING TO A 40' A BRANCH CIRCUIT) ARE INSTALLED, A SEPARATE SIUBPANEL MUST BE INSTALLED BETWEEN THE ENCHARGE UNITS AND ENPO ER TO COMBINE THE ENPOWER CIRCUITS TOGETHER. ALL CIRCUIT BREAKERS IN THE SUBPANEL MUST BE SUITABLE FOR BACK -FEEDING-, PER. NEC 4" 8, 6(D')_ 3, VERIFY THAT AC VOLTAGE AT THE SITE IS WITHIN RANGE: SINGLE-PHASE L1 TO L2 VOLTAGE MUST MEASURE BETWEEN 211 AND 264 VAC; WHILE L-N SHOULD MEASURE BETWEEN 106 AND 132 VAC. RECOMMENDED: 1. THE BUILDING SHOULD BE DESIGNED TO WITHSTAND EARTHQUAKES, 2. THE WATERPROOF AND PROPERLY VENTILATED AREA IS RECOMMENDED. (IP55) 3. INSTALL THE PRODUCT OUT OF REACH OF CHILDREN AND ANIMALS. CSreuid f ValEage Drop 1.509 Csrcult Z VoI$age Drop 1 1.579 ELECTRICAL NOTES ALL EQUIPMENT TO BE LISTED BY UL OR OTHER NRTL, AND LABELED FOR ITS APPLICATION. 2. ALL CONDUCTORS SHALL BE COPPER, RATED FOR 600 V AND 90 DEGREE C WET ENVIRONMENT. 3. WIRING, CONDUIT, AND RACEWAYS MOUNTED ON ROOFTOPS SHALL BE ROUTED DIRECTLY TO, AND LOCATED AS CLOSE AS POSSIBLE TO THE NEAREST RIDGE, HIP, OR VALLEY. A WORKING CLEARANCES AROUND ALL NEW AND EXISTING ELECTRICAL EQUIPMENT SHALL COMPLY. 5. DRAWINGS INDICATE THE GENERAL ARRANGEMENT OF SYSTEMS. CONTRACTOR SHALL FURNISH ALL NECESSARY OUTLETS, SUPPORTS, FITTINGS AND ACCESSORIES TO FULFILL APPLICABLE •D' D STANDARDS. 6. WHERE SIZES OF SOLADECK, RACEWAYS, AND CONDUITS ARE NOT SPECIFIED, THE CONTRACTOR SHALL ACCORDINGLY. 7. ALL WIRE TERMINATIONS SHALL BE APPROPRIATELY LABELED AND READILY VISIBLE. 8. MODULE GROUNDING CLIPS TO BE INSTALLED BETWEEN MODULE FRAME AND MODULE SUPPORT RAIL, PER THE GROUNDING CLIP MANUFACTURER'S INSTRUCTION. 9. MODULE SUPPORT RAIL TO BE BONDED TO CONTINUOUS COPPER G.E.C. VIA WEEB LUG OR ILSCOGBL-4DBT LAY -IN LUG. POLARITY10. THE GROUNDEDO i i• NEGATIVE. 11. TEMPERATURE I . A RATINGS #'.F... ALL CONDUCTORS, TERMINATIONS, BREAKERS, OR OTHER DEVICES ASSOCIATED WITH THE SOLAR PV SYSTEM SHALL BE RATED FOR AT LEAST 75 DEGREE C. r EE 4C� w E All LUNEX POWER INC. 4721 N GRADY AVE TAPA FL 33614 LIC : CVC57085 PHONE: 813-540-8807 REVISIONS DESCRIPTION DATE REV tea^' DATE: 05/31 /2023 PROJECT NAME & ADDRESS > N Q> d" c+ } W (.) z -j �g Z LL I LW _ IY LL U c a UJ O h N DRAWN BY ES SHEET NAME WIRING CALCULATIONS SHEET SIZE ANSI 11" X 17" SHEET NUMBER PV-7 LABEL-1: LABEL LOCATION: AC DISCONNECT ELECTRICAL SHOCK HAZARD TERMINALS ON THE LINE AND LOAD SIDES MA BE ENERGIZED IN THE OPEN POSITION LABEL- 2: LABEL LOCATION: AC DISCONNECT COMBINER MAIN SERVICE PANEL SUBPANEL MAIN SERVICE DISCONNECT CODE REF: NEC 690.13(B) LABEL- 3: LABEL LOCATION: PRODUCTION METER UTILITY METER MAIN SERVICE PANEL SUBPANEL CODE REF: NEC 705.12(C) & NEC 690.59 mylebol"NA111 LABEL- 4: 1 ARPI I nrATIC)N- MAIN SERVICE PANEL SUBPANEL MAIN SERVICE DISCONNECT COMBINER CODE REF: NEC 11027(C) & OSHA 1910.145 (f) (7) LABEL- 5: LABEL LOCATION: MAIN SERVICE PANEL (ONLY IF SOLAR IS BACK -FED) SUBPANEL (ONLY IF SOLAR IS BACK -FED) CODE REF: NEC 705.12(D) & NEC 690.59 LABEL- 6: LABEL LOCATION: MAIN SERVICE PANEL (ONLY IF SOLAR IS BACK -FED) SUBPANEL (ONLY IF SOLAR IS BACK -FED) CODE REF: NEC 705.12(B)(3)(2) TURN RAPID SHUTDOWN SWITCH TO THE "OFF" POSITION TO sOLAR ELECTRIC SHUT DOWN PV SYSTEM PV PANELS AND REDUCE SHOCK HAZARD IN THE ARRAY LABEL- 7: LABEL LOCATION: AC DISCONNECT CODE REF: IFC 605.1 tll(l) & NEC 690.56(C) LABEL- 10: LABEL LOCATION: MAIN SERVICE PANEL SUBPANEL AC DISCONNECT CODE REF: NEC 690.54 LABEL- 11: LABEL LOCATION: MAIN SERVICE DISCONNECT (ONLY IF MAIN SERVICE DISCONNECT IS PRESENT) CODE REF: NEC 690-13(B) m LABEL- 12: LABEL LOCATION: PRODUCTION METER (ONLY IF PRODUCTION METER IS USED) LABEL-13: LABEL-14: LABEL LOCATION: EMT/CONDUIT RACEWAY SOLADECK/JUNCTION BOX CODE REF: NEC 690.31 (D) (14) �lol-amm;=EMBM w1milliziIjitlijis: IQ• [MYN LABEL- 15: LABEL LOCATION: AC DISCONNECT CODE REF:NFPA I (11. 12.2, 1. 1. 1. 1) I, THE RAPID SHUTDOWN LABEL SHALL BE LOCATED ON OR NO MORE THAN 3 FT (I M) FROM THE SERVICE DISCONNECTING MEANS 2. (HEIGHT OF LABEL IS 3/8 IN, ISE MM), IN WHITE ON A RED BACKGROUND) AC DISCONNECT 2 OF 3 Effin LABEL- 15: LABEL LOCATION: MAIN SERVICE PANEL SUBPANEL AC DISCONNECT CODE REF: NEC 690.54 ONNECT 3 OF 3 117, 2 ffil Mil = MAIN SERVICE PANEL SUBPANEL AC DISCONNECT CODE REF: NEC 690.54 LABEL- 17: LABEL LOCATION: ESS DISCONNECT CODE REF: NEC 706.15(C) LUNEX POWER INC. 4721 N GRAD' AVE TAMPA FL 33614 LIC #: CVC57085 PHONE: 813-540-8807 REVISIONS DESCRIPTION DATE REV DATE: 05/31/2023 PROJECT NAME & ADDRESS >: C-4 < q Lo cy) z cle) W z _j Z LL Ill LD 00 _j U) LU C( w = >_ LL cl) 00 C14 LLJ N rC:) DRAWN BY ESR SHEET NAME LABELS SHEET SIZE ANSI B 11" X 17" SHEET NUMBER PV-8 LL x ► :#l► x •In I i LgImaj al Is (N) AC DISCONNE BACKUP LOADA ENPHASE ENPO TRANSFER DISCONN ENPHASE COMBINER.a AC DIS • 310 r iII IN*, r ♦ r i� �r � i. rr�' � � i �' �' .� (ALL PLAQUES AND SIGNAGE WILL BE INSTALLED AS OUTLINED WITHIN: NEC .•! • : 705.10]) LABELING NOTES: • 1 x 1 x •! i x 001-0- 3. MATERIAL BASED ON THE REQUIREMENTS OF AUTHORITY HAVING JURISDICTION. LABELS4. O BE OF DURABILITY WITHSTANDR O INVOLVED 0 5. LABELS TO BE A MINIMUM LETTER HEIGHT OF ON RED BACKGROUND; AND PERMAINENT AFFIXED 1 . -�� . LUNEX POWER INC. 4721 N GRADY AVE TAMPA FL 33614 LIC #: CVC57085 PHONE: 813-540-8807 REVISIONS DESCRIPTION DATE REV DATE: 05/31 /2023 PROJECT NAME & ADDRESS i-LLJ N Z Lu J co Z >- LL J g ' 1 eee ✓VJ Ca J W � } LL 0 00 IZ N LLI o N DRAWN BY ESR SHEET NAME PLACARD SHEET SIZE ANSI B 11" X 17" SHEET NUMBER PV-9 SMAf? Now am= ffvf��PE 10 AT LUNmmmmm POWEER WWoV, L"I.JINEXPOVIER, COm MADE IN MAILAND LUNEXPOWERJINC T;4721 N GRADY AVE AM PA F L 33614 HIGH CONVERSION EFFICIENCY Module efficiency up to 210% 6,ro rh 'advance; c4 technology fall-- a',d m 0 11 e p,"),,v e r o u t p u t n, w ea k I ig k t c ndlkton, such �,s cloudy dav!i, wmmamm morning and sunset EXTENDED MECHANICAL PERFORMANCE hl,,oduip certified to ,vd (54000 Pa) r25') r7') LAL-111 EX( P10MVPtA LUNEX POWER INC. 4721 N GRADY AVE TAMPA FL 33614 LIC #: CVC57085 PHONE: 813-540-8807 REVISIONS DESCRIPTION DATE REV DATE: 05/31/2023 PROJECT NAME & ADDRESS >� N < -q- �: CLIP) Uj z CY) w () z _j Z LL w co U) —j LLI < Ill r U— 00 Cif 00 N LLJ C:) N I, DRAWN BY ESR SHEET NAME EQUIPMENT SPECIFICATION SHEET SIZE ANSI B 11" X 17" SHEET NUMBER Pv-1 1 PHASE Our newest 108 Microinverters are the industry's first microggrid-forming, software - defined microinverters with split -phase power conversion capability to convert DC power to AC power effir iently The brain of the semicondUCtOr -based irricroinverter is our proprietary alopfication-specific integrated circuit (ASIC) which enables the microinverter to operate in grid -tied or off -grid modes. This chip is built in advanced 551 technology vaid t high speed digital logic and has super -fast response times to changing loads and grid -events, alleviating constraints on battery sizing for home energy systems. � o ffl/" ­­ �M, ­o? ja " ol, Pars. of tfs, E np hase E trer C, y 5 ys t em, Ser e, s Kj5 Series Mcrorrtavler: redefirra rc-lobifty tOctf,ariverters [rrteylrasore e Enphase iQ Rynevfotiaai ds sath rnote "lloin ore millirat curinu !,at se Em,hao-e tO Gateway, and to Enishace App vnionitonrot hours of powei-on cotirol. s'naloug an indstry- jr,d anslyssis software leoctro; lirnredwarrsuij of eip to 25 years C"a"ne<r PV moduf Is "tuackly a i"d aaaly tc, f0 a &,nes ir:R& c,coa, MorGifr`vai"rofs a ,-,,it Lis-,-,C as Micioinver-ters using the Q DOC-2 adapter "'i Rapid Sh ut Cosa; Equip rnery arrd or rifir rn, ort a rmnrrfactur8r's inn actions. 2022 Er poase Energy 411 rartts reserved. E nphaas, this Errpt.au e logo, lQ8 Ifficroinverter s. and other narri-s are Trademarks of Eriphase Energy ins, Data urbje,,. lockrange Easy to install L ightwei ight and compact with pfug-n-play connectors Power Line Communication (PLC) between components Faster installation with, simple ngo­ofire cabling High productivity and reliability Produce power even esiren the grid is down' More than orte million cumulative hoursof testing Class 11 double -insulated enclosure Optimized for the latest high- povirared PV modules Microgrid-forming Conapfies With the, latest advancedgrin supis , ort Remote automatic updates for the forest grid requirements Configurable to support a wide range of grid proffles Meats CA Rule 21 (UL 1741-SA) requirferents Commonky imed rrodufe.*avrsags` re 235 - 350 235 - 440 Module cortisatibifity 60-ceil/120 hd!,-cell 6 -,ell/120 hat 66-ce'V1,32 haff ceR and 72- cel/144 half c-If MPOT voitage range U 27-37 2-9-45 Operating range 1 25 48 25-58 Min/max stars orstrige V 30/48 30/58 Max fopuf DC voltase 7 50 60 Max DC-urreotlinnodilevc! A, 15 Ovef,iortage dtsys DC coo, DC part baskfeed currerc ,-A 0 my array cardiguiration W UncrounJeJ arrato No addittional DC aides arcelectror, raquinwAC side prixtectror requires may 2CA per bromn crrcuit Peak outtaut Power VA 245 300 Max conlioucius output prover va 240 -190 rorfknal (L-L) voltage/rang- "1 24 0 / 2`11 - 264 ch.as continuous ouraut icrxrertr A to L21 Norninail frequencv HZ 60 Eattorded �-qtcrncvarrge yz 50 - 66 AC short circurt fault current over 3 cries 2 Max units per 20 4, L � br3non, arcurV ,6 13 Tota i har =ri distcrtlor, 'so overvoltare- .lass AC port W AC port backfeed currertt rra, 30 Pcwef facro, carting to Grint,d co,,r far vj,m,abje) C135eacitrrg - 0.8ossagirs, Pear affs-'ien-v % 97,5 97,6 CEC vieighted effolcroy % 97 97 Night-raia, isserer consumptlom r,W SO Ambient terniaeraturs, rarrsile -401C to -60C (-4G, F to -1401F) Relative humfiaty iarrge 49 to,100% (conderising) DC Conrowtor tyae Mi Dvrntor;&�,ra (HxVAD) 212mrrr '&3-i x IT5 rnm (6.9 x 302 irtrn 0_2­) vvefgr- 1,08 1 (Z38 ita) coalirsl roroet-tion - no fw,,,A Appic eci fa =act locations vto iadlutknn, degrere PC` 3 Err bsure Class if doutsfe-ittsiWarec, osrros�xn rpsnuira polymi er000sure Envirom rategory / UV exposure rating SEMA Tyi 6 / outdoor CARule 2l (li 174!-SA), UL 62I09-1,UL1741/lEi FCC los-H5 Claw BJCES-0003 Class 3, CANVCSA-C22.21s,0,1071-;3i The product is UL. Listed as PV RLptd Shut Down, Equipment and conforms voth 14EC 2014, NEC 2(oT and NEC 2020 section 69022 and 0211- 2018 Rule 64 21,188, Rapid Sni,toccsvn of las aystams, for AC wnd D C oanxti eosax iostallpd accord "no to On rvwhatr i;rroail ed es tin Ci Systern Cort r o ter 2 manufactugens instructions. roe or s M, 1741, (1) No enforced DC/AC ratio. See the cornpatibilrp, cafcijartrit at ht*ps�/Jlirk,enph,,ac--,. ,,n,/n;odr ie-c,�ripatib,iity K) 8 and Korlol us supooits Vft phis ke. 24 OV (2) Maximum cantinuoua, i Dr- current is 1064 (3) Nominal vorage rangecar be eatenced beyond rrormnal ff rpouired inctalkui,x-a o0y. bytil-, utiffty. (4) Linvis may vary. Refer to Oca! reosiirementstociefirm. therrurnt)er of furcriarriverters per brarch in your area. KzBSP-DS-0002-01-Eis US-201222 0347 ULOPiE ;a0W—;4 LUNEX POWER INC. 4721 N GRADY AVE TAMPA FL 33614 LIC #: CVC57085 PHONE: 813-540-8807 REVISIONS DESCRIPTION DATE REV DATE: 05/31/2023 PROJECT NAME & ADDRESS < 3: co Of Uj Z C') W ( ) Z CO Z >_ g >- M U) LU < W 77 5- ILL U) = 00 CL C14 Ujr) cN DRAWN BY ESR SHEET NAME EQUIPMENT SPECIFICATION SHEET SIZE ANSI B 11" X 17" SHEET NUMBER PV-12 Enphase IQ Combiner 4/4C X-!Q-AM1-240-4 X-IQ-AMl-240-4C LmItu earn n'�o-e ,—s'l enphase.com Enphase IQ Combiner 4/4C MODEL NWAABER MECHANHLAL DATA A a n;'^.I e N ANI�� 2U %tmwn r-'c-'s-ro accr�,-� !nENPHASE ,, rn. ENPHASs,,ja ep"c-E LUNE,[`- LUNEX POWER INC. 4721 N GRADY AVE TAMPA FL 33614 LIC #: CVC57085 PHONE: 813-540-8807 REVISIONS DESCRIPTION DATE REV DATE: 05/31/2023 PROJECT NAME & ADDRESS >: CeP L0 (y) z cy) Z ILL w CO U) —j L11 ry < w = >- LL ILL U) 00 (N UJ cr:) N DRAWN BY ER SHEET NAME EQUIPMENT SPECIFICATION SHEET SIZE ANSI B I I" X 17" SHEET NUMBER PV-1 3 Enphlase EnpowCam, ,dN, 1- o6d 7i- ",_;i g� -j Jv pa� h p UP hf 71 o ean rore about Enpha se rofffer r5g,,.,, v s:t eiRphasezorn, C*kENPHASE. Enphase Enpower MODIEL NUMBEP ACCESSORES a,l- REPLACEMENT PARTS io Iearn rnone, albou' E� rjhase offeriniyi, vki� enphase.com ENPHASE. LLIMP-4E LUNEX POWER INC. 4721 N GRAY AVE TAMPA FL 33614 LIC #: CVC57085 PHONE: 813-540-8807 REVISIONS DESCRIPTION DATE REV DATE: 05/31/2023 PROJECT NAME & ADDRESS >: < 3: LLJ z (y) uj Uz I co Z u- u� co —J U) LLJ uj = LL LL U) co n c"'I UJ 0 N DRAWN BY ESR SHEET NAME EQUIPMENT SPECIFICATION SHEET SIZE ANSI B 11" X 17" SHEET NUMBER PV-14 1-1, 111-Achoarge 10 j, v "t, "R M T abu,,,l F olffermrjs v�s, ENPHASE. Enphase Encharge 10 MODEL NUMIBER Tr , f &E, E n 3- -16, k F� 8 u 8 A ACCESSORig-S i,ae OUTPUT (ACI 240 VAC Rd'tec' (ccnt.m,,x-,.pt �Xl,JeFl 3,R4 kVA, %n ",fta"oe rar"ge 24C 2' 264 W; 16 A 2 -1 M Rc� nd' tn, BATTERY p 1,11h I i3 V raC nge bo tz", Yf", -1 MECHANHICAL DATA "A" " -1 1! ap ..,lg'lll FEATURES AND COAAPL�ANCE W, , o) ftup!Kd—st, —conn LF- ENPHASE, LAUIP-4 P of E "Al LUNEX POWER INC. 4721 N GRADY AVE TAMPA FL 33614 LIC #: CVC57085 PHONE: 813-540-8807 REVISIONS DESCRIPTION DATE REV DATE: 05/31/2023 PROJECT NAME & ADDRESS LcIll) W co w () Z —j pp z L. U) LLJ < w T- LL Of o 00 n clj LLJ DRAWN BY ESR SHEET NAME EQUIPMENT SPECIFICATION SHEET SIZE ANSI B 11" X 17" SHEET NUMBER PV-15 C'rosslRall Sy to I- () SS 1:), a i I LI'Ll, -X Sy Sy r—'0E" sh X P K i 4 0 0, 4 0 U G 7 2 Lag So'n E'14,-5/16 x 4 SS 4W0359 S M ossRad 49-X.- IVU' I'laork 4,, 5,95, 4-10070i 4 8 X 4 8 d C, J 4 00 48-X 1166' of !810H c,�- Diarl 4000662. 40006"S, 40,100663 s A 8", X, d ClossPtaO 44-X folflH o; Dan, i4 4V 0- 1, 0 X Cl ter.'::. q S��ver cir- a�k 1400060H GR E---� -11-K)(42' , 40004 P0, t' Camp Y 'Hidden, E,.-,,,d Clarnp) 40000050-H 37,7 ksi (260 NuN-Pa') 0,47 fbsfft (0,6,99 Rgkn' 370 0 � 14 -5 0 i 03 6 8 3 orn, Z' Dimensions in [mrn] Inches stru(wfa! values and suarl char'-C' if", d(U'llrdang-e ooth Akjnrwl;F-N Desl,Jfi ['11,11,MLial and 46('E 7-116 � UL2703 Irsted Sys','-rn for hire-ind Boraling LUNEX POWER INC. 4721 N GRADY AVE TAMPA FL 33614 LIC #: CVC57085 PHONE: 813-540-8807 REVISIONS DESCRIPTION DATE REV DATE: 05/31/2023 PROJECT NAME & ADDRESS >: CK z W z CO Z u- ui > LLJ cr LL C/) 00 N UJ N ro- DRAWN BY ESR SHEET NAME EQUIPMENT SPECIFICATION SHEET SIZE ANSI B 11 " X 17" SHEET NUMBER PV-16 We support PV systems Formerly Everest Solar Systems^ Splice Foot XL Patent Pending I L Solive Foat XL 2 K2 EverSe a! 3 M5 x 60 lag screws 4 1-Salt Cr Hex Not Set Technical Data Roof Type Material Rlnsh Roof Connertion Code Corr ipliance Compatibility IL1000162 ISPlice Foot XL Kit Mill Composition shingle Aluminum, wlth stainless steel hardware Mill 1,45 x 60 lag screws UL 2-1703 CrossRail 44-X, 4184, 48-XL, 80 is We support Pit systems Formerly Everest Solar Systems 04 C1,11 0 0 — - - ------------ H N LUNEX POWER INC. 4721 N GRADY AVE TAMPA FL 33614 LIC #: CVC57085 PHONE: 813-540-8807 REVISIONS DESCRIPTION DATE REV DATE: 05/31/2023 PROJECT NAME & ADDRESS < dt LO (y) ILI' LLJ z CY) W ( ) z Z LL LLJ U) Uj U- C/) 0400 LLJ c:) N r DRAWN BY ESR SHEET NAME EQUIPMENT SPECIFICATION SHEET SIZE ANSI B 17"--- SHEET NUMBER PV-17 # Stamped Seamless Construction # 18 Gauge Galvanized Steel # Powder Coated Surfaces 'I * Flashes into the roof deck 0 3 Roof deck knockouts .5", 75% 0 5 Centering dimples for entry/exii fittings or conduit 0 2 Position Ground lug installed 0 Mounting Hardware Included "Fuse holders and terrmn4l blocks: added rn the field must be UL ![;tent or recognized and meet 600 VDC 30 AMP I I OC for fuse holders 600"Y 50 AMP 90C far rail rnounted terminal bforks end 600 V 175 ANIP 90C for Power DistribuIran Blocks, Use Capp Vxre Conductors SolaDecir Model SD 0783 � 111;111I� 1�1� 1 111111 i Available Models Model SD 0783 - (3 r fixed Din Rail) Model SD 0786 - (6" slotted Din Rail) Models SD 0783-41 and SD 0786-41 are labeled and ETL listed UL STD 11 741 according to the UL s,rD 1741 for photovoltaic combiner en(u0SUreSr Max Rated - 60OVDC, 120AMPS **Typical System Configuration 4- Din Rail Mounted Fuse Holders 60OVDC 30 AMP I- Power Distribution Block 600VDC 175AMP I - Bus Bar with UL lug "Typical System Configuration 4- Din Rail Mounted Fuse Holders 600VDC 30 AMP 4- Din Rail Mounted Terminal Blocks Bus Bars with UL lug condurt or fiffings base is center dimpled fror finilig locations, Model So 0783-41, wgred with Model SD 0786-41, wired with Din Ra4 mounted fuse holders, Din Rail mounted fuse hobders bus, bar and power distrititition terrninal blocks and bus bars block. RS TC Enterprises, /ric - 2219 Heimstead Road - Eau Cliare, W1 54 703 Far product inforrnation call 1(866) 367-7782 LL Y��XPODW LUNEX POWER INC. 4721 N GRADY AVE TAMPA FL 33614 LIC #: CVC57085 PHONE: 813-540-8807 REVISIONS DESCRIPTION DATE REV DATE: 05/31/2023 PROJECT NAME & ADDRESS >: < co Z W () Z -j M Z LL —j W co J LIJ R >- U- cl� U) 7 00 EL Uj O N DRAWN BY ESR SHEET NAME EQUIPMENT SPECIFICATION SHEET SIZE ANSI B 11 " X 17" SHEET NUMBER PV-1 8