HomeMy WebLinkAbout23-6389Z', 911 T , IIII
i M 0
5335 Eighth Street
Zephyrhills, FL 33542
Phone: (813) 780-0020
Fax: (813) 780-0021
BGC-006389-2023
Issue D. 06/22/2023
REINSPECTION FEES: (c) With respect to Reinspection fees will comply with Florida Statute 553.80(2)(c) the
local government shall impose a fee of four times the amount of the fee imposed for the initial inspection or
first reinspection, whichever is greater, for each subsequent reinspection.
Notice: In addition to the requirements of this permit, there may be additional restrictions applicable to this property that
may be found in the public records of this county, and there may be additional permit required from other governmental
entities such as water management, state agencies or federal agencies.
1,11MRIIIIIII 10111RITY11111, 111 11 11 � 11 .
Complete Plans, Specifications add fee Must Accompany Application. All work shall be performed in
accordance with City Codes and Ordinances. NO OCCUPANCY BEFORE C.O.
NO OCCUPANCY BEFORE C.O.
CONTRACTOR SIGNATURE FIE IT OFFICE
.NERMIT EXPIRES IN 6 MONTHS WITHOUT APPROVED INSPECTIO
CALL FOR INSPECTION - 8 HOUR NOTICE REQUIRED
PROTECT CARD FROM WEATHER i
813-780-0020
City of Zephyrhills Permit Application Fax-813-780-0021
Building Department
r
Date Received
Phone Contact for Permitting "2 ;L
e-1
Owner's Name I Iffor r,;, 1, hex
7 7±=�
.h AA he, �A�.j Owner Phone Number
Owner's Address 100 .5,C04-1 4-11e,
Owner Phone Number
Fee Simple Titleholder Name
Owner Phone Number
Fee Simple Titleholder Address
JOB ADDRESS 7
LOT #
SUBDIVISION
PARCEL ID#E3:r
(OBTAINED FROM PROPERTY TAX NOTICE)
WORK PROPOSED NEW CONSTRF--]
INSTALL
ADD/ALT SIGN EK DEMOLISH
REPAIR
PROPOSED USE SFR
Comm OTHER
TYPE OF CONSTRUCTION BLOCK
FRAME STEEL
ss
DESCRIPTION OF WORK
/1
BUILDING SIZE E E, 4: d � � SCE FOOTAGE HEIGHT
-T� 4ciE IV �k �E �E-4L �Clu C c-"E-WI�E,k i-kx--t JE -t,k t,lux t iE W iu om,E-qc-t w- W- W- W---c -uc-X: k C k- W- C
[�BUILDING VALUATION OF TOTAL CONSTRUCTION,f'�
[�j!]ELECTRICAL
=PLUMBING
=MECHANICAL
=GAS ROOFING
FINISHED FLOOR ELEVATIONS I I
AMP SERVICE PROGRESS ENERGY = W.R.E.C.
VALUATION OF MECHANICAL INSTALLATION
SPECIALTY = OTHER
FLOOD ZONE AREA =YES
BUILDER
COMPANY
A--
SIGNATURE
REGISTERED
N _j
—FEE CURREN
Address
License #
ELECTRICIAN
COMPANY
SIGNATURE
REGISTERED
( /N
11�EE CURRENY_LN
Address
License #
PLUMBER
COMPANY
SIGNATURE
REGISTERED
FEE CURREN
Address
License
MECHANICAL
COMPANY
SIGNATURE
REGISTERED
LYIN
FEE CURREN Ljj
Address
License
OTHER
COMPANY
SIGNATURE
REGISTERED
Y l N
FEE CURREN
Address
License
PI=-QInPKITIAI Att—h /?\ Qlf Pin— 191 —tc of Pin— /1 t —f of F-- f7--- P-r)-NA/ f—
813-780-0020 City OfZephvrhi|lsPermit Application Fa» 13-780-0« 1
Building Department
NOTICE OpDEED RESTRICTIONS: Theundomignedunderstandothatmis permit may be subject to "deed" restrictions" which may be more restrictive
than County latiThe undersigned assumes responsibility for compliance with any applicable deed restrictions.
UNLICENSED CONTRACTORS AND CONTRACTOR RESPONSIBILITIES: If the owner has hired a contractor or contractors to undertake work, they
may be required to be licensed in accordance with state and local regulations. If the contractor is not licensed as required by law, both the owner and
contractor may be cited for a misdemeanor violation under state law, If the owner or intended contractor are uncertain as to what licensing requirements
may apply for the intended work, they are advised tocontact the Pasco County Building Inspection Division —Licensing Section at 727-847- 8009.
Furthermore, if the owner has hired a contractor or contractors, he is advised to have the contractor(s) sign portions ofthe "contractor Block" ofthis
application for which they will be responsible. If you, as the owner sign as the contractor, that may be an indication that he is not properly licensed and is
not entitled tnpermitting privileges inPasco County.
TRANSPORTATION IMPACT/UTILITIES IMPACT AND RESOURCE RECOVERY FEES: The undersigned understands
that Transportation Impact Fees and Recourse Recovery Fees may apply to the construction of new buildings, change of use in existing buildings, or
expansion of existing buildings, as specified in Pasco County Ordinance number 89-07 and 90-07, as amended. The undersigned also understands, that
such fees, aomay ue due, will beidentified at the time of permitting. It is further understood that Transportation Impact Fees and Resource Recovery
Fees must u,paid prior mreceiving o"certificate ofoccupancy" orfina|pove,ro|oasm.|ftxe project does not involve ncertificate u[occupancy urfinal
power release, the fees must be paid prior to permit issuance. Furthermore, if Pasco County Water/Sewer Impact fees are due, they must b*paid prior
tnpermit issuance inaccordance with applicable Pasco County ordinances.
CONSTRUCTION LIEN LAW (Chapter 713, Florida Statutes, as amended): If valuation of work is $2,500.00 or more, I certify that 1, the applicant,
have been provided with a copy of the "Florida Construction Lien Law —Homeowner's Protection Guide" prepared by the Florida Department of
Agriculture and Consumer Affairs. If the applicant is someone other than the "owner", I certify that I have obtained a copy of the above described
document and promiseingoodosimtodoUwy,nmmo''owne/'p,iortovommonoom*nt.
CONTRACTOR'S/OWNER'S AFFIDAVIT: I certify that all the information in this application is accurate and that all work will be done in compliance with
all applicable laws regulating construction, zoning and land development. Application ishereby made toobtain apermit uxuowork and installation as
indicated. | certify that no work or installation has commenced prior to issuance of ponnu and that all work will be performed to meet standards of all
laws regulating construction, County and City codes, zoning regulations, and land development regulations in the jurisdiction, I also certify that I
understand that the regulations of other government agencies may apply to the intended work, and that it is my responsibility to identify what actions
must take ,oun|ncompliance. Such agencies include but are not limited to:
' Department ofEnvironmental Protection -Cypress Bayheade, Wetland Areas and Environmentally Sensitive
Lands, Water/Wastewater Treatment.
- Southwest Florida Water Management Dintriot'VVe||a, Cypress Boyheodn, Wetland An*as, Altering
Watercourses.
' Army Corps of Engineers -Seawalls, Oookn. Navigable Waterways.
- Department of Health & Rehabilitative Services/Environmental Health Unit-VVe||o, Wastewater Treatment,
Septic Tanks.
- USEnvironmental Protection Agency -Asbestos abatement.
- Fodera|AviationAuthority-Runvvuya.
| understand that the following restrictions apply tuthe use nrfill:
- Use offill ionot allowed inFlood Zone ^VW" unless expressly permitted.
- If the fill material is to be used in Flood Zone ''A"^ it is understood that a drainage plan addressing a
"compensating volume" will be submitted at time of permitting which is prepared by professional engineer
licensed by the State of Florida.
' If the f||| material is to be used in Flood Zone ^A" in connection with o permitted building using stem vva||
construction, | certify that fill will beused only tofill the area within the stem wall.
- If fill material is to be used in any area, | certify that use of such fill will not adversely affect adjacent
properties. If use of fill is found to adversely offeoi adjacent prupertiee, the owner may be cited for violating
the conditions of the building permit issued under the attached permit application, for lots less than one (1)
acre which are elevated by fill, an engineered drainage plan is required.
If I am the AGENT FOR THE OWNER, I promise in good faith to inform the owner of the permitting conditions set forth in this affidavit prior to
commencing construction. I understand that a separate permit may be required for electrical work, plumbing, signs, wells, pools, air conditioning, gas, or
other installations not specifically included in the application, A permit issued shall be construed to be a license to proceed with the work and not as
authority to violate, cancel, alter, or set aside any provisions of the technical codes, nor shall issuance of a permit prevent the Building Official from
thereafter requiring a correction of errors in plans, construction or violations of any codes, Every permit issued shall become invalid unless the work
authorized by such permit is commenced within six months of permit issuance, or if work authorized by the permit is suspended or abandoned for a
period of six (6) months after the time the work is commenced. An extension may be requested, in writing, from the Building Official for a period not to
exceed ninety (90) days and will demonstrate justifiable cause for the extension. If work ceases for ninety (90) consecutive days, the job is considered
abandoned.
OWNER R AGENT CON
WKo is re er own o me or has/ ve produced
uL/ c�7�^7�
nmm/smonmo [//`
�m�v`"� ' cnmm
Elm
R A N D i N, C,, 141 E W 0 11",JUD
1.077 West Blue Heron Blvd.
West Palm Beach, FL 33404
800372,7932
wwwatlasbtwxonn
This letter is required in order for Atlas to apply for permit(s) to install signs at your location.
It must be signed by an authorized officer (or owner) of your company and must be notarized.
UMMM
Jennifer Carr, VP of JPMorgan Chase Bank, NA,_Property Owner or agent of:
____ZNk3ALRl2VP__ZEE_H_Y R ±ULLa—EL—
Address
pick-up permits and erect signage at the above address on our behalf.
Jennifer Carr, VP of JPMorgan Chase Bank, NA
\
XI
roperty,Owne�.,or Agent (Please type or print) A , � t
%
lSijnatur of Property Owner or Agent Date
1111 Polaris Parkway, Columbus, OH 43240
Mailing Address
Telephone Number
7
r
r
This instrument was acknowledged before me thisr� Day of CC', 2020,
Notary Public (Signature)
015Y-Y - NO 11-A kl_� I q_�
t
-Z Notary Public Printed Name)
0
Personally Known-0
Produced Identification
Direct Mount Illuminated Channel Letters- Sign C
Sq Ft - 36.85
Scale: 1/2" = 1'-0"
14'-0 Y2"
REVIEW DATE, gJ
CITY OF ZEPHYRHILLS)�
BUILDING OFFICIAL"' V'n`
MEM=
M
Formed Blu,
7 W'
3 7A"— ' -1 4"�
End View
OCTOGON
FASTENER SCHEDULE - FLUSH MOUNT CHANNEL LETTERS
3 Places Each Letter, 4 Places Each Logo (Minimum)
*** All Fasteners Shall Be Spaced Evenly ***
Wall Material AnchorType
CONCRETE (3KSI) or
HOLLOW MASONRY
1/4" TAPCONS OR EQUIVALENT WITH MIN
1.25" OF EMBEDMENT
1/4" EXPANSION ANCHORS WITH MIN 2.5"
OF EMBEDMENT
1/2" PLYWOOD
(NO ACCESS BEHIND)
1/4" TOGGLE BOLTS
1/4" WOOD SCREWS OR TAPCONS, FULL
EMBEDMENT
METAL STUDS OR METAL
PANELS
#14 METAL SCREWS TO MIN 18ga STEEL OR
0.090" ALUMINUM
HOLLOW WALL (BLOCKING
BEHIND)
1/4" THRUBOLTS
1/4" X 5- LAGS
040 ALUMINUM
.040
T
RETURNS
ETURNS--L] WALL
1110
" TRIM CAP---,
LED
LIGHT PODS
40d
POWER SUPPLY
3/16"-
ACRYLIC FACE
FASTENER
SCHEDULE
WEEP HOLES _�7r
_DISCONNECT SWITCH
ulxlelwllrers
L Lab..w. �t
LWM
ELECTRIC SIG
CONNECTS TO EXISTING POWER
C—L— TO
Conforms to the requirements of the 7th Edition (2020) of the Florida Building Code sections 1609and 3107, V(ult) = 140 mph, Exposure category= C, Risk category =11
John J.Orlando PE LLC- 165 Old Ridge Road -Macon, GA 31211 -478731 5394-jjorlando@cox.net - Florida registration #0044089 job 6023ASA sheet 1 of 2
1635 N. Dale Mabry Hwy.
Lutz, FL 33548
Office: (813) 948-2220
Fax: (813) 948-2403
Manager@AppleSignAndAwning.com
CUSTOMER:
Chase Bank
LOCATION:
7800 Gall Blvd.
'T In
Job name Chase (sign u)
Job# 6023ASA
Sign company: Apple Sign And Awning
Installation location: 78W f3alt Slvd. Zophyribills, FL 33541
Section 3107 and 1609 of Florida Building Code 2020 and Chapter 30 ASCE 7-16 applies.
Application of wind pressures using the alternative all heights method for components and cladding
Type of structure: flush mounted LED channel letters and logo
Occupancy Category: 11
Wind velocity (3 sec gust), FBC 2020, section 1609.3: 140 mph
Wind pressure (qz) 50.2 psf
Net Pressure Coeficient (Onet) from Figure 30.7-2
Components and cladding not in areas of discontinuity - walls and parapets -1,09
Wind Pressure -54.7 PSI
Wind load applied between wall and structure, pulling structure away from wall
Load carried by tension in fasteners connecting structure to wall
maximum height of structure to be attached
2,63 it
maximum width of structure to be attached
Z63 rt
effective projected area factor
1,00
projected area of each component to be attached
6.9 tt'2
wind load
-377 IDS
allowable tension load per fastener to
150 lbs
even number of fasteners minimum of 2 =
-4
number of fasteners practically required due to structure shape
4
weight of structure is approximately
10 IIDS
allowable shear load per fastener to
100 los
average shear load per fastener =
26 lea
Mounting surface construction is:
Use methods
Method 1 - 1/4" A36 Threaded rod or GR2 through bolts into a blocking member.
safe working tension load = 160 pounds
safe working shear load = 200 pounds
bW lt%vmMderosq_iiet/stev�Llreaources/2.nMgies/bol!LtiLfiiI
Method 2 - Lag bolts into framing members,
-use 1/4" galvanized lag bolts with at least 3" of embedment into framing members.
- allowable pull out load = 225 pounds
rucfion /.2QP1ans1Tdb1es IA20f2efere 1/620W awall/QQStrenathl
Method 3 - 1/4-20 SS Toggler zip toggle anchors (BBS)
allowable pull out load = 125 lbs
allowable shear out load = 100 lbs
MWL0290
NOTE:. Design assumes that fasteners are installed according to manufacturer's
instructions, using correct size drill.
Method 4 - Hilti 1/4" Kwik Bolt with 2 1/2" embedment
allowable loads in grout filled cmu
allowable tension load = 150 lbs
allowable shear load = 380 lbs
NOTE:. Design assumes that fasteners are installed according to manufacturers
instructions, using correct size drill.
Mps —1/wwwalk
Method 5 - 1/4" Tapcon
depth of embedment in hollow concrete bock = 1 114"
allowable tension strength = 250 lbs
allowable shear strength = 620 lbs
b!Wa1bMMLtWreohqad con1pRqg1_s/01frY1
Method 6 - #14 self tapping sheet metal screws to min 18ga steel or 0.090" aluminum
T tw_& 2L—' t - allowable tension (pull out) load = 400 pounds
Method 7 - 1/4" wood screws in 1/2" plywood
- allowable tension load = 150 pounds
References:
ASCE 7-16
The 7th Edition (2020) of the Florida Building Code sheet 2 of 2
John J. Orlando PE LLC 0044089
165 Old Ridge Road
Macon, GA 31211
(478) 731-5394
jjoriando@cox.net
OR4 to."
14 eo,
0 004408
9
rw-
- "Willi %1"'
0
Sq Ft - 36.85
101-0%11
mmw��
mam=
Frontage: 62'
14'-0 Y2"
4"
2'-7 Y2"
.7S"
Aluminum
Return
.125"
Translucent
_Y4"
blue acrylic
returns
End View
LETTER
All
Formed Blw
733'"
3 3m"-
End View
OCTOGON
FASTENER SCHEDULE - FLUSH MOUNT CHANNEL LETTERS
3 Places Each Letter, 4 Places Each Logo (Minimum)
*** All Fasteners Shall Be Spaced Evenly ***
Wall Material Anchor Type
CONCRETE (3KSI) or
HOLLOW MASONRY
1/4" TAPCONS OR EQUIVALENT WITH MIN
1.25" OF EMBEDMENT
1/4" EXPANSION ANCHORS WITH MIN 2.5"
OF EMBEDMENT
1/2" PLYWOOD
(NO ACCESS BEHIND)
1/4" TOGGLE BOLTS
1/4" WOOD SCREWS OR TAPCONS, FULL
EMBEDMENT
METAL STUDS OR METAL
PANELS
#14 METAL SCREWS TO MIN 18ga STEEL OR
0.090" ALUMINUM
HOLLOW WALL (BLOCKING
BEHIND)
1/4" THRUBOLTS
[1/4" X 5" LAGS
P1,1117-1114191EW mil
iMlll
3116"---
ACRYLIC FACE
Z*T,TfAill�51
0500090190a
nmln��
I --DISCONNECT SWITCH
Underwriters
NO im L
ELECT ft1c SIGN
CONNECTS TO EXISTING POWER —1-I T. U1 -
Conforms to the requirements of the 7th Edition (2020) of the Florida Building Code sections 1609 and 3107, V(ult) = 140 mph, Exposure category = C, Risk category = 11
John J. Orlando PE LLC - 165 Old Ridge Road - Macon, GA 31211 - 478 731 5394 -jjorlando@cox,net - Florida registration # 0044089 job 5923ASA sheet 1 of 2
Est. Electrical Load
3.20 Amps @ 120 Volts
Electrical Reg'mts
(1) 20 Amp/120 Volt Circuits
1635 N. Dale Mabry Hwy.
Lutz, FL 33548
Office: (813) 948-2220
Fax: (813) 948-2403
Manager@App[eSignAndAwning.com
DATE: 05/12/2023
CfST0i
Chase Bank
LOCATION:
7800 Gall Blvd.
Job name Chase (sign 8)
Job# 5923ASA
Sign company: Apple Sign and Awning
Installation location: 7800 Gall Blvd, Zephyrhills, FL 33541
Section 3107 and 1609 of Florida Building Code 2020 and Chapter 30 ASCE 7-16 applies.
Application of wind pressures using the alternative all heights method for components and cladding
Type of structure: flush mounted LED channel letters and logo
Occupancy Category: 11
Wind velocity (3 sec gust), FBC 2020, section 1609.3 140 mph
Wind pressure (qz) 50,2 psf
Net Pressure Coeficient (Cnet) from Figure 307-2
Components and cladding not in areas of discontinuity - walls and parapets -1.09
Wind Pressure -54.7 psf
Wind load applied between wall and structure, pulling structure away from wall
Load carried by tension in fasteners connecting structure to wall
maximum height of structure to be attached
2.63 tt
maximum width of structure to be attached
2,63 Tt
effective projected area factor
too
projected area of each component to be attached
6.9 tt"2
wind load
-377 10s
allowable tension load per fastener to
160 los
even number of fasteners minimum of 2 =
A
number of fasteners practically required due to structure shape
4
weight of structure is approximately
forIDS
allowable shear load per fastener to
100 IDS
average shear load per fastener =
2,6 ibs
Mounting surface construction is
Use methods:
Method 1 - 1/4" A36 Threaded rod or GR2 through bolts into a blocking member.
safe working tension load = 160 pounds
safe working shear load = 200 pounds
qiqp_L/VWdLrosq_Lot/st elresqurces/,gnaLables/bolts ht?nl
_ _qv_
Method 2 - Lag bolts into framing members.
-use 1/4" galvanized lag bolts with at least 3" of embedment into framing members.
- allowable pull out load = 225 pounds
b Ut_ffiYNm sie gg eftles,%AlandsoM/Const uqborf/.2QEl a§.te er�L/L _5crew/.Z0 Vittld vall/.20kogthl
�
Method 3 - 1/4-20 SS Toggler zip toggle anchors (BBS)
allowable pull out load = 125 lbs
allowable shear out load = 100 lbs
bAtP§//t%&9_r -Bolts pal
�.,A E - H e&v ut -To le yjQ�
NOTE:. Design assumes that fasteners are installed according to manufacturer's
instructions, using correct size drill.
Method 4 - Hilti 1/4" Kwik Bolt with 2 1/2" embedment
allowable loads in grout filled cmu
allowable tension load = 150 lbs
allowable shear load = 380 lbs
NOTE:. Design assumes that fasteners are installed according to manufacturer's
instructions, using correct size drill.
hiWsflvvM- 1h 'nedm s a�/qLocuments/hQ6191 _M_ ter_Q�-L 3009615_pdf
Method 5 - 1/4" Tapcon
depth of embedment in hollow concrete book = 1 1/4"
allowable tension strength = 250 lbs
allowable shear strength = 620 lbs
LUps_L/vWk itymedripad qcLnVpg1:LaLsffi/fmRL duqL-talo docLufDqnts/pL yqt��/aZlta tachqicaidL�Lte df
q__q/ -__ qd_ - _pqc�n :_p__
Method 6 - #14 self tapping sheet metal screws to min 18ga steel or 0,090" aluminum
d_qtasqeet.2df
- allowable tension (pull out) load = 400 pounds
Method 7 - 1/4" wood screws in 1/2" plywood
QEL*_crgwL/-Z0 —Pu I 1,�df
- allowable tension load = 150 pounds
References
ASCE 7-16
The 7th Edition (2020) of the Florida Building Code sheet 2 of 2
John J. Orlando PE LLC 0044089
165 Old Ridge Road
Macon, GA 31211
(478) 7315394
jjorlando@cox.net
11.0x'A J_ OR4 NO
No 0044089
STATE OF
.0
N
g
Direct Mount Illuminated Channel Letters- Sign A
Sq Ft
101-0%11
012M=
Frontage: 66'
REVIEW DATE -
CITY OF ZEPHYRHILLS
BUILDING OFFICIAL
14'-0 Y2"
2'-7 Y2"
4"
.7S"
Aluminum
Return
I
.125"'
Translucent
Yf 41
blue acrylic
returns
End View
LETTER
Al
Formed Blu
7 3°"
3 --- 1- 4"
T
FASTENER SCHEDULE - FLUSH MOUNT CHANNEL LETTERS
3 Places Each Letter, 4 Places Each Logo (Minimum)
*** All Fasteners Shall Be Spaced Evenly ***
Wall Material Anchor Type
CONCRETE (3KSI) or
HOLLOW MASONRY
1/4" TAPCONS OR EQUIVALENT WITH MIN
1.25" OF EMBEDMENT
1/4" EXPANSION ANCHORS WITH MIN 2.5"
OF EMBEDMENT
1/2" PLYWOOD
(NO ACCESS BEHI N D)
1/4" TOGGLE BOLTS
1/4" WOOD SCREWS OR TAPCONS, FULL
EMBEDMENT
METAL STUDS OR METAL
PANELS
#14 METAL SCREWS TO MIN 18ga STEEL OR
0. 090" ALUMINUM
HOLLOW WALL (BLOCKING
BEHIND)
1/4" THRUBOLTS
1/4" X 5" LAGS
.040 ALUMINUM
ETURNS
RETURNS
WALL
1 TRIM CAP
LED
LIGHT PODS
POWER SUPPLY
3116'
ACRYLIC FACE
/ FASTENER --SCHEDULE
WEEP HOLES------ --
DISCONNECT SWITCH
qEbE W � THE L ELECTW
T-
1E III. Laborawiesint
ELEITRI`2 SIGN
ONNECTS TO EXISTING POWER fOMVLIES
C0 T. - 1.
Conforms to the requirements of the 7th Edition (2020) of the Florida Building Code sections 1609 and 3107, V(ult) = 140 mph, Exposure category = C, Risk category = 11
John J. Orlando PE LLC - 165 Old Ridge Road - Macon, GA 31211 - 478 731 5394 - jjoriando@cox.net - Florida registration # 0044089 job 5823ASA sheet 1 of 2
Est. Electrical Load
3.20 Amps @ 120 Volts
Electrical Req'nnts
(1) 20 Amp/1 20 it Circuits
1635 N. Dale Mabry Hwy.
Lutz, FL 33548
Office: (813) 948-2220
Fax: (813) 948-2403
Manager@App[eSignAndAwning.com
CUSTOMER:
Chase Bank
LOCATION:
7800 Gall Blvd.
=0121M�iW
Job name
Job#
Sign company:
Installation location:
Section 3107 and 1609 of Florida Building Code 2020 and Chapter 30 ASCE 7-16 applies.
Application of wind pressures using the alternative all heights method for components and cladding
Type of structure: flush mounted LED channel letters and logo
Occupancy Category:
Wind velocity (3 sec gust), FBC 2020, section 1609.3,
Wind pressure (qz)
Net Pressure Coeficient (Chet) from Figure 30.7-2
Components and cladding not in areas of discontinuity - walls and parapets
Wind Pressure
Wind load applied between wall and structure, pulling structure away from wall
Load carried by tension in fasteners connecting structure to wall
maximum height of structure to be attached
maximum width of structure to be attached
effective projected area factor
projected area of each component to be attached
wind load
allowable tension load per fastener to
even number of fasteners minimum of 2 =
number of fasteners practically required due to structure shape
weight of structure is approximately
allowable shear load per fastener to
average shear load per fastener=
Mounting surface construction is:
Use methods:
Method 1 - 1/4" A36 Threaded rod or GR2 through bolts into a blocking member.
- safe working tension load = 160 pounds
safe working shear load = 200 pounds
hl!p llwww.derose.rnettst, eve/rgso,rees(,gngtablaslboits.tttrpl,
It
140 mph
50.2 lost
-1.09
-54.7 psf
2.63'tt
2.63 tt
1,00f
-377 ibs
150 IDS
4
4
10 IDS
100 IbS
2.6
Method 2 - Lag bolts into framing members.
-use 1/4" galvanized lag bolts with at least 3" of embedment into framing members.
- allowable pull out load = 225 pounds
htip l a.sia gfit outtands.or i ons r�^on%20Pians(T Ies `Yo26Referencpsf 20ar�1°Io206est r4ctices?Faste d, q�20, erev 2C? ifh�E.eawal° 2 trench'
Method 3 - 1/4-20 SS Toggler zip toggle anchors (BBS)
- allowable pull out load = 125 Ibs
- allowable shear out load = 100 IDS
htfts_f___?tt__q #eLcom/.dfs/„p_ SNAPTQQGI.LlQ2/0AE-Hea_-vy,;.Duty-Toggle-POlts.pdf
NOTE:. Design assumes that fasteners are installed according to manufacturer's
instructions, using correct size drill.
Method 4 - Hilti 1/4" Kwik Bolt with 2 1/2" embedment
allowable loads in grout filled cmu
allowable tension load = 150 Ibs
allowable shear load = 380 IDS
NOTE:. Design assumes that fasteners are installed according to manufacturer's
instructions, using correct size drill.
ham_ ..hi qoo /rnp aasfty masts, ,doeumentsthC3519f7631a2e 654?Teehnieal-informaiyan-A -E)f1 LOC-3€?0 3, 5.odf
Method 5 -1/4" Tapcon
- depth of embedment in hollow concrete bock = 1 1/4"
allowable tension strength = 250 Ibs
- allowable shear strength = 620 Ibs
MtTr§ Hwww.itwredhead comfax7rtaisf0lfm rodttctcatalpgidocuments1p _uctsf37tta.�canteohnc_,g1dat
Method 6 - #14 self tapping sheet metal screws to min 18ga steel or 0,090" aluminum
htt :/-1iwbu0dex,com/ d tteks select d asheet.ptlf
- allowable tension (pull out) load = 400 pounds
Method 7 - 1/4" wood screws in 1/2" plywood
ht(ps j wwwail e.cpm Po I t tDoou is EQFt crew%20PuII-py, p g
- allowable tension load = 150 pounds
References:
ASCE 7-16
The 7th Edition (2020) of the Florida Building Code sheet 2 of 2
John J. Orlando PE LLC 0044089
165 Old Ridge Road
Macon, GA 31211
(478)731-5394
horlando@cox.net
No 0044089
Direct Mount Illuminated Channel letters- Sign B
14`-0 %2"
Scale: 1/2" = 1'-0"
Frontage: 7
REV. �A`
C'Ty OF ER1`, g1"
2'-7 Y2u
.75"
Aluminum
Return
.125"
Translucent
blue acrylic
returns
am
AI
Formed Blu
%s"
3 %$„ 74„_
•• 04 •w
FASTENER SCHEDULE - FLUSH MOUNT CHANNEL LETTERS
3 Places Each Letter, 4 Places Each Logo (Minimum)
*** All Fasteners Shall Be Spaced Evenly ***
Wall Material Anchor Type
CONCRETE (3KS1) or
HOLLOW MASONRY
1/4" TAPCONS OR EQUIVALENT WITH MIN
1.25" OF EMBEDMENT
1/4" EXPANSION ANCHORS WITH MIN 2.5"
OF EMBEDMENT
1/2" PLYWOOD
(NO ACCESS BEHIND)
1/4" TOGGLE BOLTS
1/4" WOOD SCREWS OR TAPCONS, FULL
EMBEDMENT
METAL STUDS OR METAL
PANELS
#14 METAL SCREWS TO MIN 18ga STEEL OR
0.090" ALUMINUM
HOLLOW WALL (BLOCKING
BEHIND)
1/4" THRUBOLTS
1/4" X 5" LAGS
.040 ALUMINUM s^
RETURNS
acc
1" TRIM CAP7
._
LED - -
LIGHT PODS
POWER SUPPLY
3t16"—
ACRYLIC FACE
—FASTENER
SCHEDULE
WEEP HOLES
DISCONNECT SWITCH
u;t�s
ws srw,ma,re�o,o sc w,xu_ �.«DaD��E � r„�REasaE«�"rs (IL Latmratmies
aaS n45 We tmEs'"va �wwu"o9+Gw iuE SHItI � t15
ELECYRIC SIGN
CONNECTS TO EXISTING POWER COMPLIES TO U1
Conforms to the requirements of the 7th Edition (2020) of the Florida Building Code sections 1609 and 3107, V(ult) = 140 mph, Exposure category = C, Risk category = It
John J. Orlando PE LLC - 165 Old Ridge Road - Macon, GA 31211 - 478 731 5394-jjorlando@cox.net - Florida registration # 0044089 joky 5923ASA sheet 1 of 2
Est. Electrical •IJ
3.20 • • 120 Volts
Electrical
• !• •
lt Circuits
1635 N. Dale •
Lutz, FL 33548
Office: (813) • ( { 0
948-2403
CUSTOMER:
Chase Bank
• •
7800Gall Blvd.
• IMSKJOW
Job name Chase (sign B)
Job# 5923ASA
Sign company: Apple Sigri and Awning
Installation location: 7800 Gall Blvd, Zephyrhills, FL 33541
Section 3107 and 1609 of Florida Building Code 2020 and Chapter 30 ASCE 7-16 applies.
Application of wind pressures using the alternative all heights method for components and cladding
Type of structure: flush mounted LED channel letters and logo
Occupancy Category: If
Wind velocity (3 sec gust), FBC 2020, section 1609.3: 140 mph
Wind pressure (qz) 50.2 psf
Net Pressure Coeficient (Cnet) from Figure 30.7-2
Components and cladding not in areas of discontinuity - walls and parapets -1.09
Wind Pressure -54.7 psf
Wind load applied between wall and structure, pulling structure away from wall
Load carried by tension in fasteners connecting structure to wall
maximum height of structure to be attached
2.63 n
maximum width of structure to be attached
2,63 n
effective projected area factor
i .00
projected area of each component to be attached
69 nllz
wind load
-377 IDS
allowable tension load per fastener to
150 IDS
even number of fasteners minimum of 2 =
-4
number of fasteners practically required due to structure shape
4
weight of structure is approximately
10^ los
allowable shear load per fastener to
100 IDS
average shear load per fastener =
2.6 lbs
Mounting surface construction is: to be determined
Use methods: I through 7
Method I - 1/4" A36 Threaded rod or GR2 through bolts into a blocking member,
safe working tension load = 160 pounds
safe working shear load = 200 pounds
jhtq /Mww derose rietisteXe/resotLrees/ongtgb�lerLt�o-its intmi
Method 2 - Lag bolts into framing members.
-use 1/4" galvanized lag bolts with at least 3" of embedment into framing members.
- allowable pull out load = 225 pounds
r e _W!/.2QWifl&aall/.ZO AEti)atb`
_ — _yv—
Method 3 - 1/4-20 SS Toggler zip toggle anchors (BBS)
allowable pull out load = 125 lbs
allowable shear out load = 100 lbs
yy:Qkqy-T%jgle-BoLts p_)of NOTE:. Design assumes that fasteners are installed according to manufacturer's
instructions, using correct size drill.
Method 4 - Hilti 1/4" Kwik Bolt with 2 1/2" embedment
allowable loads in grout filled cmu
allowable tension load = 150 lbs
allowable shear load = 380 lbs
NOTE:. Design assumes that fasteners are installed according to manufacturer's
instructions, using correct size drill.
ngM/ wwvK tj Itj cq -nlmeojps/sys n asLe d ments/hO6/91 Z63152(�505egh i cql _T QQC LQC_qQQ94�35 f _L_qc_u_ �jaE _pA
Method 5 - 1/4" Tapoon
depth of embedment in hollow concrete bock = 1 1/4"
allowable tension strength = 250 lbs
allowable shear strength = 620 lbs
09
Method 6 - #14 self tapping sheet metal screws to min 1 8ga steel or 0.090" aluminum
brLtp LMW&itWb IqLgQ M&ft dex f/teks seLLegt dalsheet ,)f
_ _
- allowable tension (pull out) load = 400 pounds
Method 7 - 1/4" wood screws in 1/2" plywood
hqRs__/LwWw_-tllprac�com/�POCLaLs/O/Pocoments/PDF�5crew /20Pu -o_ut_pdf
- allowable tension load = 150 pounds
References:
ASCE 7-16
The 7th Edition (2020) of the Florida Building Code sheet 2 of 2
John J. Orlando PE LLC 0044089
165 Old Ridge Road
Macon, GA 31211
(478) 731-5394
j oriando@cox.net
0134 4!--o
0 5,
No 0044089
WI*I.TATE OF
* P
Direct Mount Illuminated Channel Letters- Sign C
10'-0'Y"
Scale: 1/2" = 1'-0"
Existing # Be Removed)
! t it DA E 2 ...7
J1 ) p "o
14'-0 %' I�
Ali
Formed Bluf
7 3"'
3 %s" 141
End View
OCTOGON
FASTENER SCHEDULE - FLUSH MOUNT CHANNEL LETTERS
3 Places Each Letter, 4 Places Each Logo (Minimum)
*** All Fasteners Shall Be Spaced Evenly ***
Wall Material Anchor Type
CONCRETE (3KSI) or
HOLLOW MASONRY
1/4" TAPCONS OR EQUIVALENT WITH MIN
1.25" OF EMBEDMENT
1/4" EXPANSION ANCHORS WITH MIN 2.5"
OF EMBEDMENT
1/2" PLYWOOD
(NO ACCESS BEHIND)
1/4" TOGGLE BOLTS
1/4" WOOD SCREWS ORTAPCONS, FULL
EMBEDMENT
METAL STUDS OR METAL
PANELS
#14 METAL SCREWS TO MIN 18ga STEEL OR
0.090" ALUMINUM
HOLLOWWALL(BLOCKING
BEHIND)
1/4"THRUBOLTS
1/4" X 5" LAGS
.040 ALUMINUM s^
RETURNS__.---- WAL
1" TRIM CAP -----a
LED
LIGHT PODS I
POWER SUPPLY
-
ACRYLIC FACE --
FASTENER
SCHEDULE
WEEP HOLES
�—DISCONNECT
SWITCH
iE�i�Msi��W TMiEwDEO TO BE NSTATSEDMACCOROANce WRx TxE REOtNRFl.lEwis
Nd�EI W HAt ELECTRIC CODE PNDfOR OTxER P➢PIICn
DuxOMD nxO eOxOMG Ov iwE SlDx.
Underwriters
lJt �DtLt6flE$�DL
LISPED.
ELECTRIC SIGN
CONNECTS TO EXISTING POWER
OMPLIES TD - 48
Conforms to the requirements of the 7th Edition (2020) of the Florida Building Code sections 1609 and 3107, V(ult) =140 mph, Exposure category = C, Risk category = II
John J. Orlando PE LLC - 165 Old Ridge Road - Macon, GA 31211 - 478 731 5394-jjorlando@cox.net - Florida registration # 0044089 job 6023ASA sheet 1 of 2
Est. Electrical Load
Electrical Reg'mts
Amp/1 20 Volt Circuits
Job name Chase (sign C)
Job# 6023ASA
Sign company: Apple Sign�sind Awning i
Installation location 7800 Gall Blvd. Zophyrh fts, fit, 33541
Section 3107 and 1609 of Florida Building Code 2020 and Chapter 30 ASCE 7-16 applies.
Application of wind pressures using the alternative all heights method for components and cladding
Type of structure: flush mounted L1 D channel letters and logo
Occupancy Category: II
Wind velocity (3 sec gust), FBC 2020, section 1609.3: 140 mph
Wind pressure (qz) 50.2 psf
Net Pressure Coefficient (Chet) from Figure 30.7-2
Components and cladding not in areas of discontinuity - walls and parapets -1.09
Wind Pressure -54.7 psf
Wind load applied between wall and structure, pulling structure away from wall
Load carried by tension in fasteners connecting structure to wall
- maximum height of structure to be attached
2.63 tt
- maximum width of structure to be attached
2.63'in
effective projected area factor
1.00!
- projected area of each component to be attached
6.9 tt^2
wind load
-377 fibs
allowable tension load per fastener to
160 ", IDS
- even number of fasteners minimum of 2 =
-4
- number of fasteners practically required due to structure shape
4
- weight of structure is approximately
10 Ibs
- allowable shear load per fastener to
100 ' Ibs
average shear load per fastener=
2.6 Ibs
Mounting surface construction is: to be determined
Use methods: 1 through 7
Method 1 - 1/4" A36 Threaded rod or GR2 through bolts into a blocking member,
safe working tension load = 160 pounds
safe working shear load = 200 pounds
ht#p�,f .dererse.nettstevetresoureeste,cikablestbofts.html
Method 2 - Lag bolts into framing members.
-use 1/4" galvanized lag bolts with at least 3" of embedment into framing members.
- allowable pull out load = 225 pounds
htt L ww.siegefiler am tlancis.org_f_.crnstruction°to20PlanslTables 120Reference.,_., °Fo20 na`/.20Besk%20Pradices/Fastenerstgft�' l r�g°h,20$crpw 20VVithdrawaf f 20 t en
Method 3 - 1/4-20 SS Toggler zip toggle anchors (BBS)
- allowable pull out load = 125 Ibs
- allowable shear out load = 100 Ibs
hft„ps:ltt_„ Iae.com7. dfs/SNA4'T i_ °I ,2°fo E-Heav -Dut ;fie-Bo!ts.pdf
NOTE:. Design assumes that fasteners are installed according to manufacturer's
instructions, using correct size drill.
Method 4 - Hilti 1/4" Kwik Bolt with 2 1/2" embedment
allowable loads in grout filled cmu
- allowable tension load = 150 Ibs
- allowable shear load = 380 Ibs
NOTE:. Design assumes that fasteners are installed according to manufacturer's
instructions, using correct size drill.
tttVL/_ .hilti.com/mediae/sys master/cfgcumentc(,(ri06t917631526505fElTechnica4-informiion-ASSET-_Q—LQC_300'J63 df
Method 5 - 1/4" Tapcon
- depth of embedment in hollow concrete bock = 1 1/4"
- allowable tension strength = 250 Ibs
- allowable shear strength = 620 Ibs�q
his:! _.�tw%redhaad corrttislQr[nproduC _c€..y3c}1�,o5rnei�tslpr_o,aet9 3,aggn sohrtLPf
Method 6 - #14 self tapping sheet metal screws to min 18ga steel or 0.090" aluminum
%
ht, 2 itlb. .itw i,[de .cos'ntpd€Rek aeI. at ,haets>of ° �.°� �' �s ` Of
- allowable tension (pull out) load = 400 pounds No 00 8 � «
Method 7 - 1/4" wood screws in 1/2" plywood
hops;,t N-wz.ztitarac.comlPoAr
as/0. „acumen ,tPDF/Screw`/` 0PulI-aut df
- allowable tension load = 150 pounds
TE OF
References:
ASCE 7-16
The 7th Edition (2020) of the Florida Building Code sheet 2 of 2
John J. Orlando PE LLC 0044089
165 Old Ridge Road
Macon, GA 31211
(478)731-5394
jjorlando@cox.net