Loading...
HomeMy WebLinkAbout23-6419Issue Date: 06/20/2023 REINSPECTION FEES: (c) With respect to Reinspection fees will comply with Florida Statute 553.80(2)(c) the local government shall impose a fee of four times the amount of the fee imposed for the initial inspection or first reinspection, whichever is greater, for each subsequent reinspection. Notice: In addition to the requirements of this permit, there may be additional restrictions applicable to this property that may be found in the public records of this county, and there may be additional permit required from other governmental entities such as water management, state agencies or federal agencies. "Warning to owner: Your failure to record a notice of commencement may result in your paying twice for .mprovements to your property. If you intend to obtain financing, consult with your lender or an attorney .......... Uompiete accord6ce with City Codes and Ordinances. NO OCCUPANCY BEFORE C.O. NO OCCUPANCY BEFORE C.O. CALL FOR INSPECTION - 8 HOUR NOTICE REQUIREV, PROTECT CARD FROM WEATHER i 813-780-DO20 City of Zephyrhills Permit Application Fax-813-7aa-0021 Building Department 813 rt 0086 Fee simple Titleholder Address (OBTAINED FROM PROPERTY TAX NOTICE) WORK PROPOSED NEW CONSTR F-"l ADDtALT x SIGN DEMOLISH 1-1 INSTALL REPAIR PROPOSED USE SFR COMM OTHER TYPE OF CONSTRUCTION BLOCK E] FRAME STEEL DESCRIPTION OF WORK Installation of a -roof-mounted photovoltaic solar panel system, BUILDINGS � � SQ FOOTAGE HEIGHT _ [-_-_-]BUILDING $ VALUATION OF TOTAL CONSTRUCTION MMMMIMM I =GAS ROOFING SPECIALTY = OTHER LA Nil HEDFL ORELEVATIONS FLOOD ZONE AREA 11111111111111fYES NO Sunrun Installation Services, Inc. K « a applicationFill out application,owner & Contractor sign bark of if over 1 F AMP SERVICE PROGRESS ENERGY W.R.E.CGk VALUATION OF MECHANICAL INSTALLATION - Agent (for the contractor) or Partner of Attomey (for the owner) would be someone with notarized letter from owner authorizing same OVER THE COUNTER PERMITTING (copy of contract required) Retools if shingles Sewers Service Upgrades A/C Fences (Plot/Survey/Footage) Driveways -Not over Counter if on public roadways -needs ROW 813-780-0020 City of Zephyrhills Permit Application Fax-813-78"021 Bull ding Department oil other installations not specifically included in the application. A permit issued shall be ronsned to be a license to proceed with the worx and not as authority to violate, cancel, alter, or set aside any provisions of the technical codes, nor shall issuance of a permit prevent the Building Official from thereafter requiring a correction of emors in plans, constniction or violations of any codes, Every permit issued shall become Invalid unless the work authorized by such permit Is commenced vAthin six months of permit issuance, or if work authorized by the permit is suspended or abandoned for a redact of six (6) months after the time the work is commenced. An extension may be requested, in writing, from the Building Official for a period not to exceed ninety (90) days and will demonstrate justifiable cause for the extension. If wc* ceases for ninety (90) consecutive days, the job is considered abandoned. Rome of Notary typed, printed or stamped -MI . . . . . . . . . . ......... LTIM+ +w Name of Notary typed, printed or stamped BGM �RITTANY L. DEBOUVER Commission 0 HH 259W Expires y 1, 2026 1W SHEETINDEX LEGEND SCOPE OF WORK GENERAL NOTES TABLE OF CONTENTS SE SERVICE ENTRANCE - SYSTEM SIZE: 8505W DC, 600OW AC a MODULES: (21) HAN A Q-CELLS: Q.PEAK DUO BLK gi ALL WORD SHALL COMPLY WITH 2O20 FBC (7TH ED.) AMENDMENTS TO 2018 IRC/IBC/IEBC, MUNICIPAL CODE, AND ALL MANUFACTURERS' LISTINGS AND PACE DESCRIPTIONML-G10+ 405 - INVERTERS: (1) SO REDGE TECHNOLOGIES: INSTALLATION INSTRUCTIONS. - PHOTOVOLTAIC SYSTEM WILL COMPLY WITH NEC 2017. PV-1.0 COMER SHEET MP MAIN PANEL SE600aH-USSN PV-2,0 SITE PLAN ® RACKING- S-51 VERSABRACKET VB-47 d ELECTRICAL SYSTEM GROUNDING WILL COMPLY WITH NEC 2017. PV-3.0 LAYOUT �S�ID SUB -PANEL ® PHOTOVOLTAIC SYSTEM IS UNGROUNDED. NO CONDUCTORS ARE SOLIDLY PV-4.0 ELECTRICAL LC PV LOAD CENTER GROUNDED IN THE INVERTER. SYSTEM COMPLIES WITH 690.35, ® MODULES CONFORM TO AND ARE LISTED UNDER UL 1703. PV-5.0 SIGNAGE INVERTER CONFORMS TO AND IS LISTED UNDER UL 1741. SM SUNRUN METER ® RACKING CONFORMS TO AND IS LISTED UNDER UL 2703. PM DEDICATED PV METER 4 SNAPNRACK RACKING SYSTEMS, IN COMBINATION WITH TYPE I, OR TYPE II MODULES, ARE CLASS A FIRE RATED, INV INVERTER(S) m RAPID SHUTDOWN REQUIREMENTS MET WHEN INVERTERS AND ALL 1�C;tSt4iktllltll'AC `°C�Q A V JAI / '',,�, CONDUCTORS ARE WITHIN ARRAY BOUNDARIES PER NEC 690.12(1). AC DISCONNECT(S) ® CONSTRUCTION FOREMAN TO PLACE CONDUIT RUN PER 690.31(G). 0. 85W fv DC DC DISCONNECT(S) ARRAY DC CONDUCTORS ARE SLED FOR DEBATED CURRENT. = S TATE OF ® 11.17 AMPS MODULE SHORT CIRCUIT CURRENT. �•,/ `� � OCR` ", '/''tarAL CB IQ COMBINER BOX 17.45 AMPS DEBATED SHORT CIRCUIT CURRENT [690.8 (A) & 690.8 (B)). rif il I lV0000t�� EXPIRES: 2/28/2025 ABBREVIATIONS F- i SIGNED: 06/13/2023 j_ J - INTERIOR EQUIPMENT SHOWN AS DASHED CHIMNEY ATTIC VENT S�+ t VICINITY MAP sunrun ENGINEER ADDRESS: 225 BUSH ST, SUITE 1400 SAN FRANCISCO, CA 94104 P: 949-383-0993 EC 13007964 A AMPERE AC ALTERNATING CURRENT AFC ARC FAULT CIRCUIT INTERUPTER AZIM AZIMUTH COMP COMPOSITION DC DIRECT CURRENT (E) EXISTING FLUSH ATTIC ENT PVC PIPE VENT METAL PIPE VENT 5208 TAMPA W BLVD. TAMPA, FL 33634 PHONED FAX 0 CUSTOMER RESIDENCE: ESS ENERGY STORAGE SYSTEM EXT EXTERIOR INT INTERIOR r T-VENT FRANCIS PANZER MSP MAIN SERVICE PANEL SATELLITE DISH 5434 5TH ST, ZEPHYRHILLS, FL, 33542 (N) NEWS NTS NOT TO SCALE TEL. (727) 364-6816 Oc ON CENTER FIRE SETBACKS HARDSCAPE APN: 11-26-21-0010-09100-0161 PROJECT NUMBER: 802R-434PANZ PRE-FAB PRE -FABRICATED PSF POUNDS PER SQUARE FOOT PV PHOTOVOLTAIC — PL— - PROPERTY LINE SOLAR MODULES r DESIGNER: (415) 580-6920 ex3 WHYNO ABUGAN RSD RAPID SHUTDOWN DEVICE TL TRANSFORMERLESS RAIL SCALE: NTS SHEET TYP TYPICAL v - REV NAME DATE COMMENTS COVER V VOLTS h_ t tl I. E STANDOFFS & REV: A 6/13/2023 PAGE Pv-l.o W WATTS-- LAN LANDSCAPE POR PORTRAIT FOOTING S Template version 4.0.87 m (I (N) AF \\\\\It I [I//// NN 84927 1p 'l/ 'STATE OF 0., tORID 10TAL /10111111110 6/1512023 sunrun ENGINEER ADDRESS: 225 BUSH ST, SUITE 1400 SAN FRANCISCO, CA 94104 P: 949-383-09133 EC13007964 5208 TAMPA W BLVD, TAMPA, FL 33634 PHONE 0 FAX 0 CUSTOMER RESIDENCE: FRANCIS PANZER 5434 5TH ST, ZEPHYRHILLS, FL, 33542 PROJECT NUMBER: 802R-434P,&iJZ DESIGNER: (415) 580-6920 ex3 WHYNO ABUGAN SHEET SITE PLAN REV: A 6/13/2023 PAGE PV-2.0 I ROOF INFO FRAMING INFO ATTACHMENT INFORMATION DESIGN CRITERIA MAX DISTRIBUTED LOAD: 3 PSF Max Max Max Name Type Height Type Max OC Detail Landscape OC Landscape Portrait OC Max Portrait Configuration SNOW LOAD: 0 PSF Span Spacing Spacing Overhang Spacing Overhang WIND SPEED: 138 MPH 3-SEC GUST. CORRUGATED METAL, S.S. LAG SCREW AR-01 TRAPEZOIDAL [VB471 - UR I 1-Story I 2X4 PRE -FABRICATED TRUSSES 5'- 1" 24" S-5! VERSABRACKET VB-47 I 6'- 0" 2'- 4" 6'- 0" 2' - 2" STAGGERED 5/16"X4.5": 2.5" MIN. EMBEDMENT CORRUGATED METAL, AR-02 TRAPEZOIDAL [VB47] - UR 1-Story 2X4 PRE -FABRICATED TRUSSES 5'- 0" 24" S-5! VERSABRACKET VB-47 6'- 0" 2'- 4" 6'- 0" 2' - 2" STAGGERED CORRUGATED METAL, E W AR-03 TRAPEZOIDAL [VB47] - UR 1-Story 2X4 PRE -FABRICATED TRUSSES 5'- 11" 24" S-5! VERSABRACKET VB-47 6'- 0" 2'- 4" 6'- 0" 2'- 2" STAGGERED -- - --- - < AR-04 CORRUGATED METAL, TRAPEZOIDAL [VB47] - UR 1 -Story 2X4 PRE -FABRICATED TRUSSES 5- V 24" S-5! VERSABRACKET VB-47 6'- 0" 2' - 4" 6' - 0" 2'- 2" STAGGERED io 8492 Of, ?V6 D1 - AR-01 - SCALE: 1/8" = V-0" D2 - AR-02 - SCALE: 1/8" = 1'-0" STATE OF AZIM:156' AZIM:245' PITCH: 16' PITCH.- 18' 11 /01YAL -- 6'-4" V-2" 13'- 6/15/2023 2' 9" T+-F- 6'TYP- 6'-2" 6'TYP--T— 12'-5" 3' 4" 2'-7" sunrun ENGINEER ADDRESS: 225 BUSH ST, SUITE 1400 SAN FRANCISCO. CA 94104 P 949-383-0993 EC13007964 5208 TAMPA W BLVD, TAMPA, FL 33634 D3 - AR-03 -SCALE: 1/8" V-0" D4 - AR-04 - SCALE: 1/8" 1 *-0" INSTALLERS SHALL NOTIFY ENGINEER OF AN PHONE 0 FAX 0 AZIM:155' AZIM:336' POTENTIAL STRUCTURAL ISSUES OBSERVED PITCH: 17' PITCH: 17' PRIOR TO PROCEEDING W/ INSTALLATION. CUSTOMER RESIDENCE: FRANCIS PANZER IF ARRAY (EXCLUDING SKIRT) IS WITHIN 12" 5434 5TH ST, ZEPHYRHILLS, FL, --31'-4"----H V-8" BOUNDARY REGION OF ANY ROOF PLANE 33542 9'-2" 10'-5" 1,-9" EDGES (EXCEPT VALLEYS), THEN ATTACHMENTS NEED TO BE ADDED AND 1-4" OVERHANG REDUCED WITHIN THE 12" TEL. (727) 364-6816 APN: 11-26-21-0010-09100-0161 BOUNDARY REGION ONLY AS FOLLOWS: U6TYP ALLOWABLE ATTACHMENT SPACING PROJECT NUMBER: 6'TYP _4 6-2" 6'TYP— 6'. 2" INDICATED ON PLANS TO BE REDUCED BY 50o/,. 802R-434PANZ ALLOWABLE OVERHANG INDICATED ON PLANS TO BE 1/5TH OF ALLOWABLE DESIGNER: (415) 580-6920 ex3 ATTACHMENT SPACING INDICATED ON PLANS. WHYNO ABUGAN 5'-4" SHEET LAYOUT REV: A 6/13/2023 PAGE PV-3.0 120/240 VAC SINGLE PHASE SERVICE METER #: DUKE ENERGY 4385433 UTILITY GRID NOTE: TOTAL PV BACKFEED = 31 25A EXISTING USED FOR INTERCONNECTION CALCULATIONS 200A MAIN BREAKER (END FED) EXISTING 200A (N) LOCKABLE SO KEDGE TECHNOLOGIES: MAIN BLADE TYPE SE600OH-USSN FACILITY PANEL AC DISCONNECT 6000 WATT INVERTER JUNCTION BOX PV MODULES LOADS 3 R EQUIVALENT 2/ HANWHA Q-CELLS: Q.PEAK DUO BLK (N) 35A PV n, ML-G 10+ 405 BREAKER AT (21) MODULES OPPOSITE END OPTIMIZERS WIRED IN: OF BUSBAR (1) SERIES (1) SERIES OF (11) OPTIMIZERS EXISTING SQUARE D LOAD RATED DC DISCONNECT (1) SERIES OF (10) OPTIMIZERS A- Vlj� /////// (E) I OOA 100A MAIN DU222RB WITH AFC{, RAPID SHUTDOWN POWER OPTIMIZERS SUBFEEDER BREAKER 3R, 60A,2P COMPLIANT S440 S BREAKER 120/240VAC �E FACILITY ---------- I.AR'.11N. EXISTING 125A SUB = S TATE OF FACILITY PANEL ✓-p 46 LOADS z o R ///",ONAL EXPIRES: 2/28/2025 SIGNED: 06/13/2023 CONDUIT SCHEDULE # CONDUIT CONDUCTOR NEUTRAL GROUND I NONE (4) 10 AWG PV WIRE NONE (1) 6 AWG BARE COPPER 2 3/4" EMT OR EQUIV. (4) 10 AWG THHN/THWN-2 NONE (1) 8 AWG THHN/THWN-2 3 3/4" EMT OR EQUIV. (2) 8 AWG THHNfTHWN-2 (1) 10 AWG TH H N/THWN-2 (1) 8 AWG THHNfrHWN-2 E EXISTING = EXISTING EXISTING EXISTING MODULE CHARACTERISTICS S440 OPTIMIZER CHARACTERISTICS: HANWHA Q-CELLS: Q. PEAK DUO BLK MIN INPUT VOLTAGE: 8 VDC ML-G10+ 405: 405 W MAX INPUT VOLTAGE: 60 VDC OPEN CIRCUIT VOLTAGE: 45.34 V MAX INPUT ISC: 14,5 ADC MAX POWER VOLTAGE: 37.39 V MAX OUTPUT CURRENT: 15 ADC SHORT CIRCUIT C-URRENT: 11.17 A SYSTEM SIZE: 8505 W SYSTEM OPEN CIRCUIT VOLTAGE: 11 V SYSTEM OPERATING VOLTAGE: 380 V MAX ALLOWABLE DC VOLTAGE: 480 V SYSTEM OPERATING CURRENT: 22,39 A SYSTEM SHORT CIRCUIT CURRENT: 30 A 7-emplate�_verston-4,0,67 i1Y LOCATION:LABEL k 2017: », s 6 #O NOT RELOCATE DEVICEOVERCURRENT LABEL LOCATION: ADJACENT TO PV BREAKER (IF APPLICABLE). LABEL LOCATION: PHOTOVOLTAIC nu i fLtiV i I AC COMBINER APPLICABLE). SOURCES:TILITY u ■ ji pal DI 7w PV SOLAR ELECTRIC SYSTE11 LABEL LOCATION: UTILITY SERVICE METER AND MAIN SERVICE PANEL. RAPID LABEL LOCATION: INSTALLED WITHIN TOF SHUT DOWN 6 it t 02019:1204.53 EXTERIORLABEL LOCATION: INTERIOR AND DC CONDUIT • LABEL PHOTOVOLTAICAC DISCONNECT(S), PER • LABEL LOCATION: INVERTER(S), DC DISCONNECT(S). PER CODE(S): CEC 2019: 690.53, NEC 2017: 690.53 Cif � ' # # #f IM SWCH TO THE "OFF' wa"w # l SHOCK HAZARD ARRAY. LABEL LOCATION: ON OR NO MORE THAT I M (3 FT) FROM THE SERVICE ARE CONNECTED. NOTES AND SPECIFICATIONS: 110.21 (B), UNLESS SPECIFIC INSTRUCTIONS ARE REQUIRED BY SECTION 690, OR IF REQUESTED BY THE LOCAL AHJ. • SIGNS AND LABELS SHALL ADEQUATELY • LABELS SHALL BE PERMANENTLY AFFIXED TO THE EQUIPMENT OR WIRING METHOD AND SHALL NOT BE HAND WRITTEN. WORDS, COLORS AND SYMBOLS. • SIGNS AND LABELS SHALL COMPLY WITH ANSI Z535,4-201 1, PRODUCT SAFETY SIGNS AND LABELS, UNLESS OTHERWISE SPECIFIED. NOT • :am STATE OF l� �j 1ONAl.W EXPIRES: 2128/2025 SIGNED: 06/13/2023 Temnf2t"P_ Upr.-4n f Astra v.1.782 June 15, 2023 sunrun WS CAT 1 Subject : Structural Certification for Proposed Residential Solar Installation, VA E W Matthew Wals, State Fl Job Number: 802R-434PANZ; Rev A c E N PJamesrofessional Engineer,hLicenseof No.orida, 84923 Client: Francis Panzer ,16 84923 This item has been digitally signed and sealed Address: 5434 5th St, Zephyrhills, FL 33542 , e I / '/ by James Matthew Walsh, PE on 6/15/2023 11" ""ONV A!, using a Digital Signature, Printed copies of this STATE OF document are not considered signed and sealec N and the SHA authentication code must be verified on electronic copies, Attn: To Whom It May Concern /ONAt- VaVO Afield observation of the existing structure at the address indicated above was performed by a site survey team from Sunrun. Structural evaluation of the loading was based on the site observations and the design criteria listed below. Design Criteria: • 2020 FBC (7th Ed.)AMENDMENTS TO 2018 IRC/IBC/IEBC, 7-16 ASCE & 2018 NDS Basic (Category 11) Wind Speed V = 138 mph, Exposure B • Ground Snow Load = 0 psf Based on this evaluation, I certify that the alteration to the existing structure by the installation of the PV system meets the requirements of the applicable existing and/or new building code provisions referenced above. Additionally, I certify that the PV module assembly including all attachments supporting it have been reviewed to be in accordance with the manufacturer's specifications,