Loading...
HomeMy WebLinkAbout23-6817Ir -1 Mma"VTORANA-M Address: 1380 North University Dr PLANTATION, FL 33322 Phone: (954) 953-1119 INSTALLATION FIRE ALARM - System Acceptance Inspection Alarm Fire Permit Fee 50- 5335 Eighth Street Zephyrhills, FL 33542 FIRE-006817-20 3 Phone: (813) 780-0020 Issue Date: 09/12/2023 - I L2J77 Building Valuation: $2,670.00 Electrical Valuation: Mechanical Valuation: Plumbing Valuation: Total Valuation: $2,670.00 Total Fees: $150.00 Amount Paid: $150.00 Date Paid: 9/12/2023 1:40:45PM Contractor: COMMERCIAL FIRE & COMMUNICATION $50.00 Fire Alarm System Plan Review $50.00 REINSPECTION FEES: (c) With respect to Reinspection fees will comply with Florida Statute 553.80(2)(c) the local government shall impose a fee of four times the amount of the fee imposed for the initial inspection or first reinspection, whichever is greater, for each subsequent reinspection. Notice: In addition to the requirements of this permit, there may be additional restrictions applicable to this property that may be found in the public records of this county, and there may be additional permit required from other governmental entities such as water management, state agencies or federal agencies. I I ! I i 1 111 1 F I I I , I 1 11 11 1 1 1 1 11 W=-F.t 0 Rol* Z V 0 4 accordance with City Codes and Ordinances. NO OCCUPANCY BEFORE C.O. NO OCCUPANCY BEFORE C.O. IR 50 W 010 PEPT OFFICEU mr-111""01-110A SEQUENCE OF OPERATION SYSTEM OUTPUTS CONTROL UNIT NOTIFlCATION ANNUNCIATION o� ALL INITIATION INDIVIDUALLY ANNUNCIATED AND WILL TRANSMIT AS SINGLE POINT TO CENTRAL STATION FORMATTED AS 'CONTACT ID'. c o c o c ci Q Fo 2 hG�' o is o m,Cj Q�F,,� c qj SYSTEM INPUTS A I B I C D E I F I G H 1 MANUAL PULL STATION • • • 2 SMOKE DETECTOR • • • 3 SPRINKLER WATERFLOW • • • 4 ISPRINKLER VALVE TAMPER • • 5 ISYSTEM TROUBLE I 10 1 • Ci— i 75cd WP DI —I MI-1 MI-2 MI_j B S P F AIM AIM (EOL NAC CKT. #1) FA WF VS BA ® O 0 � DO FACU SS FA1.0 _ 120Vac/20Amp Dedicated ckt. W/Surge Suppression FA - SPRINKLER SUPERVISORY SYSTEM - RISER DIAGRAM SCALE: N.T. S FA - SPRINKLER SUPERVISORY SYSTEM - KEY PLAN SCALE: NTS GENERAL FIRE ALARM SYSTEM NOTES 1. WHERE CEILING HEIGHTS ALLOW, WALL MOUNTED AUDIBLE APPLIANCES SHALL HAVE THEIR TOPS AT HEIGHTS OF NOT LESS THAN 90 in. AFF, AND BELOW THE FINISHED CEILING OF NOT LESS THAN 6 in. 2. WALL MOUNTED VISUAL OR AUDIBLE/VISUAL APPLIANCES SHALL BE MOUNTED SUCH THAT THE ENTIRE LENS IS NOT LESS THAN 80 in. A.F.F. BUT NOT MORE THAN 96 in. A.F.F. WHERE LOW CEILING HEIGHTS DO NOT PERMIT MOUNTING AT A MINIMUM OF 80 in. A.F.F. THE VISUAL OR AUDIBLE/VISUAL APPLIANCE SHALL BE MOUNTED WITHIN 6 in. OF CEILING. CEILING MOUNTED VISUAL OR AUDIBLE/VISUAL APPLIANCES SHALL BE PERMITTED AS ALLOWED BY NFPA72-18.5.4, SPECIFICALLY LISTED FOR APPLICATION AND SPACED IN ACCORDANCE WITH 18.5.4.3. 3. DO NOT MOUNT SMOKE AND/OR HEAT DETECTORS CLOSER THAN 3' TO ANY SUPPLY REGISTER OF THE A/C SYSTEM. 4. WHEN CEILING MOUNTING SMOKE AND/OR HEAT DETECTORS SHALL BE MOUNTED NO CLOSER THAN 4" TO A SIDE WALL, OR WHEN WALL MOUNTED NO HIGHER THAN 4" OR LOWER THAN 12" FROM THE TOP OF THE DETECTOR TO THE CEILING. 5. CONTROL RELAYS MUST BE MOUNTED WITHIN 3' OF THE CONTROLLED CIRCUIT OR APPLIANCE. 6. IF FIRE ALARM CONTROL RELAYS ARE TO CONTROL THE EQUIPMENT OF ANOTHER TRADE, THE OTHER MUST TERMINATE CIRCUITS TO CONTROL RELAY CONTACTS, OR LEADS !F PROVIDED. 7. UNDERGROUND/OVERHEAD WIRING ENTERING OR LEAVING A BUILDING SHALL BE INSTALLED AND PROTECTED IN ACCORDANCE WITH NFPA72-12.2.4.2/A.12.2.4.2 AND NFPA70-;ARTICLE 280. WHEN REQUIRED, 'TVSS' SHALL BE INSTALLED IN ACCORDANCE WITH NFPA70-ARTICLE 285. 8. CALCULATIONS ARE BASED ON RACEWAY/WIRE ROUTING AS SHOWN ON PLANS. ANY DEVIATION FROM THIS DESIGN MAY RESULT IN SYSTEM NOT MEETING PROPER PERFORMANCE STANDARDS. IF DEVIATION MUST BE MADE IT IS THE INSTALLERS RESPONSIBILITY TO COMMUNICATE TO THE OFFICE ANY INTENDED OR REQUIRED CHANGES. 9. WHERE HEAT DETECTORS ARE INSTALLED TO SHUT DOWN ELEVATOR POWER PRIOR TO SPRINKLER OPERATION THE DETECTOR SHALL BE INSTALLED WITHIN 2' OF EACH SPRINKLER HEAD, AND SHALL BE RATED AT 135' FIXED TEMPERATURE. 10. ONLY ASSOCIATED DEVICE WIRING IS REQUIRED ENTERING INTO BACK -BOX. ALL OTHER WIRING MAY CONTINUE PAST BACK -BOX. F M1-1 C vo 2AD1-1M1-2 o SPA M 1-3 ,B AIM PAIN/L B WF -A WP 75cd EOL NAC C KT.1 SYSTEM KEY NOTES O - CONNECT FACU TO 120VAC/20AMP DEDICATED CIRCUIT WITH SURGE SUPPRESSION. - CELLULAR COMMUNICATOR INTEGRATED WITHIN THE FIRE ALARM CONTROL UNIT. CONNECT TO CELLULAR NETWORK FOR MONITORING. O - VERIFY EXACT LOCATION AT FIELD. SYSTEII� NOTES O UL 1638 WEATHERPROOF APPLIANCE CANDELA RATING VARIES DUE TO ATMOSPHERIC CONDITIONS. (PLEASE SEE SPEC'S.) O DEVICE / APPLIANCE NUMBERING SCHEME AS FOLLOWS: 'D' = (DETECTOR)SLC LOOP NUMBER 'M' = (MODULE)SLC LOOP NUMBER 'C' = VISIBLE or AUDIBLE -VISIBLE CKT. NUMBER SCOPE OF TYORK.- PROVIDE and INSTALL: FIRE SPRINKLER SUPERVISORY SYSTEM. AREA of WORK SQUARE FOOTAGE I 28005 I SPINKLER RISER ROOM A FDC OUTSIDE (Fire Department Connection) FA - SPRINKLER SUPERVISORY SYSTEM - FLOOR PLAN SCALE : 3 / 16"=1' -0" FIRE ALARM SYSTEM SYMBOL LEGEND SYMBOL DESCRIPTION MOUNTING ELEVATION FACU FIRE ALARM CONTROL UNIT OWN CABINET 66" AFF TO TOP DOC DOCUMENT BOX OWN CABINET VERIFY IN FIELD ❑F MANUAL PULL STATION 4" SQ. x 2-1/8" w/1-GANG P-RING 48" AFF ( TOP ) AIM ADDRESSABLE MONITOR MODULE 4" SQ. x 1-1/2" MINIMUM or IN BOX BEHIND DEVICE S CP SMOKE DETECTOR (PHOTOELECTRIC) 4" SQ. x 2-1/8" SQ. TO RD. P/R CEILING SEE NOTE 3&4 N<WP HORN/STROBE - (WEATHERPROOF) MANUFACTURE SUPPLIED BACK BOX VERIFY IN FIELD -AW- END OF LINE SUPERVISORY DEVICE ON LAST DEVICE OF CIRCUIT SS SURGE SUPPRESSION GROUND FIRE ALARM SYSTEM WIRE LEGEND SYMBOL I CIRCUIT TYPE DESCRIPTION —j A IS11GNALING LINE CIRCUIT 2 - #16 AWG FPLR B INOTIFICATION APPLIANCE CIRCUIT 2 - #14 AWG FPLR * ALL JACKETED 'FREE -WIRE' CABLE TO BE RATED FOR INSTALLING ENVIRONMENT. * WHERE REQUIRED: CABLE/WIRING TO BE WITHIN MINIMUM .75" CONDUIT SYSTEM. FIRE ALARM INSTALL.9TION SHALL COMPLY JPITK.• - FL. FIRE PREVENTION CODE (7th EDITION-2020) - NFPA 70 (2017 EDITION) - NFPA 72 (2016 EDITION) - FBC (7th EDITION-2020) DEVICE COUNT DEVICE TYPE QUANTITY FIRE ALARM CONTROL UNIT 01 DOCUMENT 01 PULL STATIONS 01 MONITOR MODULE 02 SMOKE DETECTOR 01 WP HORN STROBE 01 TOTAL 07 —GROUNDING CONDUCTOR SHALL BE MIN. #14 AWG. —GROUNDING CONDUCTOR SHALL BE CONNECTED TO BUILDING or STRUCTU(RE) GROUNDING ELECTRODE or GROUNDING ELECTRODE CONDUCTOR AS DESCRIBED IN NFPA70. ALL RK SHALL COMPLY WITH NFFAO CODES AND STANDARDS -- "r-"a3N{W`dX3),1.3�dS 3�{'1 aN�13Yi13 SlliHa 31tlfl rV 3o3a LANNCO, INC ENGINEERING CONSULTING CERTIFICATE OF AUTHORIZATION # 26222 P.O. BOX 41481 ST.PETERSBURG FLORIDA 33743 (727) 345-8556 PROFESSIONAL SEAL FRANK BONGH1 FLORIDA P.E. 54702 FIRE ALARM CD N ❑ �. LO m ❑ CO U � M ~ _I U_ _ O (0 � � J >_ ry 0- � W � N � N 00 LO a" N CD LO N E 0 E L 0 C 0 No. Revision/Issue Date r • AL _&W Lam_ ' • v� v Commercial FIRE & Communications, Inc. P.O. BOX 1350 LARGO, FL. 33773 EF20001347 (727) 530-4521PH. (727) 531-0596,FAX Engineering@cfcsystems.com Sheet Title: SPRINKLER SUPERVISORY SYSTEM Drawn bv: G 1 Checked by �j Project Number: Shale #: OIX1652 FA01 , 08-11-2023 Scale: 01`of01 3/16" = Y-O"