Loading...
HomeMy WebLinkAbout23-6609Name: Lennar Homes, ILLC Address: 4301 W Boy Scout Blvd Suite 600 Tampa, FL 33607 Phone: (813) 574-5700 CONSTRUCT TOWNHOME 1541 SQ FT Transportation Impact Fee Plumbing Permit Fee Address Fee SIF I percent Fee Mechanical Permit Fee Transportation Impact Fee - City School Impact Fee - Single Family Sewer Connection Residential Fee Admin Fee / (Provider Service ) iaim I BNR-006609-2023 Issue Date: 07/17/2023 I Permit Type: Building New (Residential) Class of Work: Townhome Building Valuation: $232,680.00 Electrical Valuation: $34,902.00 Mechanical Valuation: $16,287.60 Plumbing Valuation: $23,268.00 Total Valuation: $307,137.60 Total Fees: $14,217.05 Amount Paid: $14,217.05 Date Paid: 7/17/2023 1:55:19PM 36412 Camp Fire Terrace Contractor: LENNAR HOMES LLC $3,445.20 Building Permit Fee $1,20140 $156.34 Driveway Fee $45,00 $30.00 3/4 Water Meter Residential Connection Fee $794.92 $33.53 Water Connection Residential Fee $1,140.00 $121.44 Fire Wall/Smoke Wall Inspection $15.00 $34.80 Public Safety Impact Fee -Admin $26.35 $3,353.00 Park Impact Fee - Single Family/Townhome $769.56 $2,400.00 Public Safety Impact Fee -Police $254.00 $180.00 Electrical Permit Fee $214.51 REINSPECTION FEES: (c) With respect to Reinspection fees will comply with Florida Statute 553.80(2)(c) the local government shall impose a fee of four times the amount of the fee imposed for the initial inspection or first reinspection, whichever is greater, for each subsequent reinspection. Notice: In addition to the requirements of this permit, there may be additional restrictions applicable to this property that may be found in the public records of this county, and there may be additional permit required from other governmental entities such as water management, state agencies or federal agencies. Complete Plans, Specifications add fee Must Accompany Application. All work shall be performed in accordance with City Codes and Ordinances. NO OCCUPANCY BEFORE C.O. NO OCCUPANCY BEFORE C.O. 4 CPNT :ACTOR SIGNATURE PE IT OFFICEU PERMIT EXPIRES IN 6 MONTHS WITHOUT APPROVED INSPECTION CALL FOR INSPECTION - 8 HOUR NOTICE REQUIRED PROTECT CARD FROM WEATHER 813-780-0020 City of Zephyrhills Permit Application Fax-813-780-0021 Building Department Date Received Phone Contact for Permittingg [�9=08770 __ 7763 Y i f i 1 1T Y 1 111 1 Owner's Name CAL HEARTHSTONE LOT OPTION POOL 03 L P Owner Phone Number 813.574.5700 Owner's Address 1 23975 Park Sorrento, Ste. 220, Calabasas, CA 91302 Owner Phone Number Fee Simple Titleholder Name Owner Phone Number Fee Simple Titleholder Address N/A JOB ADDRESS 36412 Camp Fire Terrace LOT# 2106 SUBDIVISION Abbott Square PARCEL ID# 04-26-21-0160-02100-0060 (OBTAINED FROM PROPERTY TAX NOTICE) WORK PROPOSED P NEW CONSTR ADD/ALT SIGN DEMOLISH INSTALL REPAIR 8 PROPOSED USE u v u SFR COMM OTHER TYPE OF CONSTRUCTION 10 BLOCK FRAME STEEL O DESCRIPTION OF WORK Multi -family / Screen Enclosure / Fence BUILDING SIZE U/R SF 1 g3g SQ FOOTAGE 1541 HEIGHT 28' JBUILDING $ 232680 VALUATION OF TOTAL CONSTRUCTION ELECTRICAL $ 34902 - ® PROGRESS ENERGY ® W.R.E.C. r AMP SERVICE PLUMBING $ 23268 MECHANICAL $ 16287.6 VALUATION OF MECHANICAL INSTALLATION =GAS ® ROOFING SPECIALTY OTHER FINISHED FLOOR ELEVATIONS FLOOD ZONE AREA DYES Do BUILDER COMPANY Lennar Homes, LLC SIGNATURE REGISTERED Y / N FEE CURREN Y / N Address 43 W Boy SC t Blvd Suite 600 Tampa, FL 33607 License # CGC1518166 ELECTRICIAN COMPANY I Edmonson Electric, Inc. SIGNATURE REGISTERED Y / N FEE CURREN Y / N Address License # I EC13005408 PLUMBER COMPANY Bayonet Plumbing, Heating & AG, Inc SIGNATURE REGISTERED Y / N FEE CURREN LILIN Address I License # I CFC042998 MECHANICAL COMPANY I Bayonet Plumbing, Heating & AC, Inc SIGNATURE REGISTERED Y / N FEE CURREN Y / N Address License # I CAC058062 OTHER COMPANY C Sterling Quality Roofing, Inc SIGNATURE r REGISTERED Y / N FEE CURREN Address License # CCC057991 IIflllllllll111111111111111111111/111//I/I/IIIIIIIIIIIIIIIIIII111111 RESIDENTIAL Attach (2) Plot Plans; (2) sets of Building Plans; (1) set of Energy Forms; R-O-W Permit for new construction, Minimum ten (10) working days after submittal date. Required onsite, Construction Plans, Stormwater Plans w/ Silt Fence installed, Sanitary Facilities & 1 dumpster; Site Work Permit for subdivisions/large projects COMMERCIAL Attach (2) complete sets of Building Plans plus a Life Safety Page; (1) set of Energy Forms. R-O-W Permit for new construction. Minimum ten (10) working days after submittal date. Required onsite, Construction Plans, Stormwater Plans w/ Silt Fence installed, Sanitary Facilities & 1 dumpster. Site Work Permit for all new projects. All commercial requirements must meet compliance SIGN PERMIT Attach (2) sets of Engineered Plans. ****PROPERTY SURVEY required for all NEW construction. Directions: Fill out application completely. Owner & Contractor sign back of application, notarized If over $2500, a Notice of Commencement is required. (A/C upgrades over $7500) ** Agent (for the contractor) or Power of Attorney (for the owner) would be someone with notarized letter from owner authorizing same OVER THE COUNTER PERMITTING (copy of contract required) Reroofs if shingles Sewers Service Upgrades A/C Fences (Plot/Survey/Footage) Driveways -Not over Counter if on public roadways..needs ROW NOTICE OFDEED RESTRICTIONS: The undersigned understands that this permit may besubject to "deed" restrictions" which may bemore restrictive UhenCountyn*gu|odonn. The undersigned assumes responsibility for compliance with any applicable deed restrictions. UNLICENSED CONTRACTORS AND CONTRACTOR RESPONSIBILITIES: If the owner has hired a contractor or contractors to undertake vvork, they may be required to be licensed in 000undanma with state and |ooe| regulations. If the oontnoobzr is not licensed as required by |aw, both the owner and contractor may be cited for misdemeanor violation under state law. If the owner or intended contractor are uncertain as to what licensing requirements may apply for the intended work, they are advised Vocontact the Pasco County Building Inspection Division —Licensing Section at727-847' 8009. Furtbermona, if the owner has hired e contractor or contractors, he is advised to have the contractor(s) sign portions of the "contractor Block" of this application for which they will be responsible. If you, an the owner sign as the oontrac\or, that may bean indication that he is not properly licensed and is not entitled to permitting privileges in Pasco County. TRANSPORTATION IMPACT/UTILITIES IMPACT AND RESOURCE RECOVERY FEES: The undersigned understands that Transportation Impact Fees and R000unoo Recovery Fees may apply 0othe construction ofnew buildings, change of use in existing bui|dings, or expansion of existing bui|dingu, as specified in Pasco County Ordinance number8Q-07 and 90-07. as amended. The undersigned also undnratandn, that such foey, as may be due, will be identified at the time of permitting. It is further understood that Transportation Impact Fees and Resource Recovery Fees must be paid prior to receiving a "certificate of occupancy" or final power release. If the project does not involve o oort|DnaUa of occupancy or final power re|uaoe, the fees must be paid prior to permit issuance. Furthermore, if Pasco Counh/VVater/Sowar Impact fees are due, they must be paid prior to permit issuance in accordance with applicable Pasco County ordinances. CONSTRUCTION LIEN LAW (Chapter 713. Florida Statutes, mmarnended): ifvaluation ofwork in$2.50O.00ormore, | certify that |, the app|ivant, have been provided with o copy of the "Florida Construction Lion Law —Homeowner's Protection Guide" prepared by the Florida Department of Agriculture and Consumer Affairs. If the applicant is someone other than the "owner", | certify that | have obtained a copy of the above described document and promise in good faith to deliver it tothe ^mwner'prior incommencement. CONTRACT0R'S/OVVNEFk`S,4FH0AV|T: | certify that all the information in this application is accurate and that all work will be done in compliance with all applicable laws regulating oonetruotinn, zoning and land development. Application is hereby made to obtain a permit to do work and installation as indicated. | certify that no work or installation has commenced prior to issuance of permit and that all work will be performed to meet standards ofall |owo regulating oonutruo<ion. County and City oodeo, zoning regulations, and land development regulations in the jurisdiction. | also certify that | understand that the nagu|oUona nfother government agencies may apply to the intended work, and that it is myresponsibility tnidentify what actions |must take Voboincompliance. Such agencies include but are not limited to: - Department ofEnvironmental Protection -Cypress Bayhaody, Wetland Areas and Environmentally Sensitive Lands, Water/Wastewater Treatment. ' Southwest Florida VVohor Management Oiotrict4NeUa, Cypress Bayheadu, VVoUond Areao, Altering VVat*roounoaa. - Army Corps ofEngineers-Seawa||n.Docks, Navigable Waterways. - Department ofHealth & Rehabilitative Son/icoa/Environmental Health Unit-VVe||o, Wastewater Treatment, Septic Tanks. - USEnvironmental Protection Agency -Asbestos abatement. - Federal Aviation Authorib+Rumwayo. | understand that the following restrictions apply 0zthe use offill: - Use uffill ionot allowed inFlood Zone ''V~unless expressly permitted. - If the DU material is to be used in Flood Zone ''A^, it in understood that o drainage plan addressing a "compensating volume" will be submitted at time nfpermitting which is prepared by professional engineer licensed bythe State ofFlorida. - If the OU material is to be used in Flood Zone ^A^ in connection with a permitted building using nhmm wall construction, | certify that fill will baused only hofill the area within the stem wall. - If fill material is to be used in any area, | certify that use of such D|| will not adversely affect adjacent If use offiU is found to adverselyowner may be cited for violating the conditions of the building permit issued under the attached permit application, for lots |oun than one (1) acre which are elevated byfill, anengineered drainage plan inrequired. If am the AGENT FOR THE OWNER. | promise in good faith to inform the owner ofthe permitting conditions set forth in this affidavit prior to commencing construction. | understand that a separate permit may be required for a|eohuo| wnrh, p|umbing, aigny, weUo, puo|o, air conditioning, gas, or other |natsUaUnne not specifically included in the application. A permit issued ohoU be construed to boa license to proceed with the work and not aoauthority hnviolate, oanoe|, a|b*r, or set aside any provisions of the technical codes, nor shall issuance of a permit prevent the Building Official from thereafter requiring a correction of errors in plans, construction or violations of any codes. Every permit issued shall become invalid unless the work authorized by such permit is commenced within six months of permit ionuanoe, or if work authorized by the permit is suspended or abandoned for a period of six (6) months after the time the work is commenced. An extension may be naqueoXed, in writing, from the Building Official for period not to exceed ninety (0O)days and will demonstrate justifiable cause for the extension. If work ceases for ninety (90) consecutive days, the job is considered abandoned. WARNING TO OWNER: YOUR FAILURE T0RECORD A NOTICE OFCOMMENCEMENT MAY RESULT |NYOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. |FYOU INTEND T0OBTAIN FINANCING, CONSULT JupmT��.11rou OWNER OR AGENT Subscribed and sworn to (or affirmed) before me this 6/29/2023 by Christopher Smith Who is/are pe nally known to me or harsihave PFQdWGe4 as identification. _Notary Public Commission N�"057 Stephanie Farmer Name of Notary typed, printed or stamped Subscribed and sworn to (or affirmed) 6/29/2023 by Christoi)her Smith Who is/are personally known to me orhas/have produced Name of Notary typed, printed or stamped DESCRIPTION: LOT 1-6, BLOCK 21, ABBOTT SQUARE PHASE 2, SITE PLAN SEC. 4, TWP. 26 S, RNG 21 E. ACCORDING TO THE PLAT THEREOF, RECORDED IN PLAT BOOK 90, PASCO COUNTY, FLORIDA PAGES 28-33, OF THE PUBLIC RECORDS OF PASCO COUNTY, (NOT A SURVEY) FLORIDA. This SITE PLAN Prepared for and Certified To: (ABBOTT SQUARE PHASE 2) PROPOSED ELEVATIONS AND GRADING Lennar Homes SHOWN HEREON ARE TAKEN FORM THE ENGINEERING PLANS OF ALL ELEVATIONS REFERENCED "ABBOTT SQUARE RESIDENTIAL", PREPARED TO NORTH AMERICAN BY"WRA" PROVIDED BY CLIENT VERTICAL DATUM OF 1988 (NAVD 88) Scale: 1 = 20' TRACT "A" (CDD) RIGHT-OF-WAY CAMP FIRE TERRACE 2s �a, BASIS OF BEARING NJ 27.,3' - ------------ 5 co .W ALK L N-89'48'04- E (P) 128.68' (P) 28.34'(�) oe (F) 28.34' I -�8.00'(!?) I inw(p)- 1 :1,0 W, (P) 1 00 PAVED PCP N 89-48.04- E (P) PARKING 391.43'(P) NJ NJ -SPACE �P 4.- C�l 0 0 LAJ lo. - All �o.o, 1� 10.0, 100lo 11.0, 11.0" FIF 11.0, 11.0, 1 1 Lo, lu 11.01 6.3' 6.3' 6.3' 6.3' 3 ' Z Z Lx) .41 �4 W LAJ .4 LIJ mo, lo.o.- 7 TRACT "B-7" .0' ENTRY ENTRY 6,3' [6.3' ENTRY ENTRY 6.3' 63, ENTRY ENTRY 7.0' 5 LOT 4 LOT 2 LOT I C� (CDD) LOT 6 Ln LOT LOT 3 LOT 7 m BLOCK21 14 NJ m OPEN SPACE BLOCK BLOCK I 0� BLOCK 21 BLOCK 21 BLOCK 21 BLOCK 21 _-i - 108'-8" Ul Ul 10 14 W LV W LV U10 i �14 PROPOSED 10 10 PROPOSED �0 0 PROPOSED W PROPOSED C? '6) �.,i PROPOSED :g PROPOSED 8 2 STORY 2 STORY 2 STORY 2 STORY 9 2 STORY q 2 STORY ATTACHED ATTACHED ATTACHED Ui ATTACHED ATTACH ATTACHED O� ATTACHED RESIDENCE RESIDENCE RESIDENCE M RESIDENCE RESIDENCE RESIDENCE -0 UNIT -A M UNIT-C M UNIT-C UNIT-C M UNIT -A _ii - 1624 b UNIT-C 1532 1624 1624 Z9 - C PR AT 2 0 T P 'T AT TACHED 0 0 C S' R HE m [RE RESIDENCE N, S _ UNIT-C 1 624 1532 1624 JOB # 15905522101 15905522102 18.0' ITT 17.3' 17.3' ITT 18.0' - 9, 01 - �_.LANAI i�LANA�1�b LANAI- LANAI 6 LANAI 15905522103 10.0, A/CDK� A/c i A/C EAEA/C I A/C DID A/C 15905522104 t28.34- (P) 28.34'(P) laou lP) 18.22� (P) I 6- 1 18.00, IPI N 89'48'04" E (P) 128.68' (P) NOTES: TRACT "B-7" O, LOT GRADING TYPE =A (CDD) PROPOSED PAD ELEVATION = 104. 10' OPEN SPACE FRONTS ET BACK = 20' SIDE SET BACK = 7.5' NOTE ENTRY WALKS ARE 3.0'CONCRETE LOT = 12611 SO. FT, SIDE SET BACK (CORNER LOT) = 10' 0.7'CONCRETE WALLS SEPARATE INDIVIDUAL UNITS LIVING AREA = 4010 SO. FT REAR SETBACK = 15' C/S-A/C UNITS ARE 31'X3.2' ENTRY = 476 SO. FT. GARAGE = 1356 SO. FT. COVERED LANAI = 652 SO. FT. PROPOSED: PATIO = NA SO. FT. MINIMUM FLOOR ELEVATIONS: 10.00' PUBLIC UTILITY EASEMENT POOL AREA = NA SO. FT. LIVING AREA: 104.77' LEGEND: CONC. DRIVE = 1200 SO. FT. GARAGE AREA: A/C & CONC PAD = 54 SO. FT. ELEVATIONS REFERENCED TO PROPOSED DRAINAGE FLOW SIDEWALK = 272 SO. FT. NORTH AMERICAN VERTICAL (00.00) = PROPOSED GRADE SIDE YARD SWALE = NA SO. FT. DATUM OF 1988 E-00.00 = EXISTING GRADE CONSERVATION AREA = NA SQ. FT. LOT OCCUPIED = 64 % APPARENT FLOOD HAZARD ZONE: 'X'COMMUNITY NO. 120235 AREA TO IRRIGATE = 36 % SURVEY ABBREVATIONS (MAP NUMBER 12101 C-0289-F) EFFECTIVE DATE: 09/26/2014 A) = ARC LENGTH (D) - DEED INV - INVERT PC = POINT OF CURVE (RI = RECORD LEGEND A/C = AIR CONDITIONER D.E= DRAINAGE EASEMENT LEE =UCENSED BUISNESS PCC = POINT OF COMPOUND CURVE VINYL FENCE AT = ALUMINUM FENCE EL OR ELEV = ELEVATION L.E = LANDSCAPE EASEMENT PCP = PERMANENT CONTROL POINT RNG = RANGE RRS = RAIL ROAD SPIKE r CONC BEE =BASE FLOOD ELEVATION EOP = EDGE OF PAVEMENT LEE - LOWEST FLOOR ELEVATION P/E = POOL EQUIPMENT R/W = RIGHT OF WAY BM = BENCH MARK ESMT = EASEMENT LS = LICENSED SURVEYOR PG = PAGE SEC = SECTION WOOD FENCE C - CURVE F/C = FENCE CORNER (M)= MEASURED PI = POINT OF INTERSECTION ASPHALT (C I =CALCULATED SN&D = SET NAIL AND DISK CENTERU NE FCM = FOUND CONCRETE MES = MITERED END SECTION PK =PARKER KALON LB#8183 MONUMENT NCF = NO CORNER FOUND R = PROPERTY LINE CHAIN LINK FENCE CM = CHAIN LINK FENCE SIR = SET 112- IRON ROD LB# 8 183 CP = CORRUGATED METAL PIPE HP = FOUND IRON PIPE O/A = OVERALL POB = POINT OF BEGINNING TBM = TEMPORARY BENCH MARK BRICK x x COL=COLUMN FIR= FOUND IRON ROD OH = OVERHEAD WIRES ) POC = POINT OF COMMENCTMENT TOB = TOP OF BANK CONC = CONCRETE FN&D = FOUND NAIL & DISK O.R. =OFFICIAL RECORDS POL = POINT ON LINE TWP = TOWNSHIP ALUMINUM FENCE C/S = CONCRETE SLAB FOP = FOUND OPEN PIPE fP) =PLAT PRC = POINT OF REVERSE CURVE U.E = UTILITY EASEMENT = COVERED CST = CLEAR SIGHT TRIANGLE, EPP = FOUND PINCHED PIPE PB = PLAT BOOK PRM = PERMANENT REFERENCE MONUMEN] VF = VINYL FENCE SURVEYOR'S NOTES: SURVEYOR'S CERTIFICATE 1708 Water Oak Drive SEE 1.) Current title information on the subject property had not been This certifies that sketch of the hereon described Tarpon Springs, Florida N Date of Site Plan: 6-14-23 furnished to Initial Point Land Surveying, LLC. at the time of this property was ma I TWP? N � ?N DWG:AS-PH 1 B-L 1-6-BL2 I -SITE SITE PLAN ,q#U44 supervision and Phone: (727)-831-1990 RG?W RG,E meets the AWA le of Practice for FloridaPLS7]23@gmaii.com I �p 1 5 �p S, Z_ 2.) This sketch was prepared without the benefit of a title search. surveys IIi)r i oard of Land LB# 8183 RG1W RG�E No instruments of record reflecting ownership, easements or S File: rights -of -way were furnished to the undersigned, unless otherwise 31 1 co, lof Pied Drawn by: DJB shown hereon. purs nt t C ion ley - 3.) Roads, walks, and other similar items shown hereon were take Sta*s n i rt Checked byJH from engineering plans and are subject to survey. Date: 6.19 - 4.) This SITE PLAN does not reflect nor determine ownership, - 2:0 00 0, REVISIONS lev n 5.) This SITE PLAN is subject to matters shown on the Plat of SfAT OR "ABBOTT SQUARE PHASE 2" 6.) Dimensions shown hereon are in feet and decimal portions Jeff M l' LUKIVA thereof. FLORI AND 7.) Contractor and owner are to verify all setbacks, building MAPP 486 169 , dimensions, and layout shown hereon prior to any construction, NOT VALID WI7MP_"19E7 ORIGINAL and immediately advise Initial Point Land Surveying, LLC. of any SIGNATURE AND SEAL OF A FLORIDA deviation from information shown hereon. Failure to do so will be LICENSED SURVEYOR AND MAPPER Initial Point Land Surveying, LLC. at user's sole risk. 106.01 Classifcation[Type of Use 70 TRANSPORTATION IMPACT FEE Rate: Sq, Ft knit: Exempt 0 Yes 0 No How Determined Impact Fee Amount Zane No. TAZ: SCHOOL IMPACT FEE Account (056) Single -Family Detached House Amount (057) Mobile Rome (05) Other Residential (123) Collection Fee Exempt =Yes = No How Determined - PARKS AND RECREATION FEE Land Account Land Credit land Total Recreation Account Recreation Credit Recreation Total Zone Total Amount $ Exempt Yes No Blow Determined Land Account land Credit land Total Facility Account Facility Credit Facility Total Exempt Yes No How Determined Total Amount__ RESOURCE FEE ERU Total Amount Prepared INSPECTIONNO CERTIFICATE OF OCCUPANY WILL BE ISSUED OR FINAL PERFORMED UNTIL THE TOTAL AMOUNTS BEEN PAID AND RECEIPTED FOR BY A CENTRAL PERMITTING OFFICE OF PASCO COUNTY ACKNOWLEDGEMENT BELOW DOES ". IMPLY ACCEPTANCE OF CONCURRENCE, BUT SIMPLY REECEIPT OF A OP, OF THIS FORM, PLACINGDI ASSESSMENT AND THE CONDITIONSOF PAYMENT FOR SAME. RECEIVED BY RECEIPT NO DATE BY Project Name: 36412 \/-RA ',V A S S Notice to Building Official of Use of Private Provider Effective January 20, 2003 Fire Terrace Parcel Tax ID: 04-26-21-0160-02100-Oil Services to be provided: Plans Review X Inspections Note: If the notice applies to either private plan review or private inspection services the Building Official may require, at his or her discretion, the private provider be used for both services pursuant to Section 553.791(2) Florida Statute. the fee owner, affirm I have entered into a contract with the Private Provider indicated below to conduct the services indicated above. Private Provider Firm: Private Provider: VIRTUAL REVIEW ASSIST, INC. Address: 747 SW 2ND AVE- SUITE 170,301,357,& 358, GAINESVILLE, FL 32601 Telephone: 813-376-3088 Email Address (Optional): deb@virtualreviewassist.com Fax: N/A Florida License, Registration or Certificate #: (LIC # BU1967/ PX2300/ BN4615) I have elected to use one or more private providers to provide building code plans review and/or inspection services on the building that is the subject of the enclosed permit application, as authorized by s. 553.791, Florida Statutes. I understand that the local building official may not review the plans submitted or perform the required building inspections to determine compliance with the applicable codes, except to the extent specified in said law. Instead, plans review and/or required building inspections will be performed by licensed or certified personnel identified in the application. The law requires minimum insurance requirements for such personnel, but I understand that I may require more insurance to protect my interests. By executing this form, I acknowledge that I have made inquiry regarding the competence of the licensed or certified personnel and the level of their insurance and am satisfied that my interests are adequately protected. I agree to indemnify, defend, and hold harmless the local government, the local building official, and their building code enforcement personnel from any and all claims arising from my use of these licensed or certified personnel to perform building code inspection services with respect to the building that is the subject of the enclosed permit application. I understand the Building Official retains authority to review plans, make required inspections, and enforce the applicable codes within his or her charge pursuant to the standards established by s. 553.791, Florida Statutes. If I make any changes to the listed private providers or the services to be provided by those private providers, I shall, within I business day after any change, update this notice to reflect such changes. The building plans review and/or inspection services provided by the private provider is limited to building code compliance and does not include review for fire code, land use; environmental or other codes. The following ataohments. are provided as requirtd- 1. Qualification statements and/or resumes of the private provider and all duly authorized representatives. I. Proof of insurance, for professional and comprehensive liability .of per occurrence relating to all services performed as aprivate provider, including tail coverage for. aminimum of 5 years subsequent to the performance of building code,, inspection services. :(signature) Print Name: Address_ Telephone Please use appropriate notary block. STATE of FLORIDA COUNTY of HILLSBOROUGH individual Beforeme, this -day Of 20— personally appeare.d who executed the foregoing instrument, and acknowledged before me that same was executed for the purposes therein expressed. C�orporation LENNAR HOMES, LL# Print Corp oration Name; ?lint Name. Christopher Smith Its: Authorized Ag ent Address: 700 NW 107th Ave. TMami, FL 33172 Telephone• No. 813-574-5700 Corporation B,foreme,this 22ND day of MAY 2023 Personally appeared of Lennar Homes, LLC::::� a —Corporation, on ..'behalf of the State oorpoTafion, who executed the foregoing instrument and acicnowledged before me that same was executed for the purposes "therein expressed. Partnership PrintPartnership Name By:, (Signature) Print Name: Its Address: Personally known 7 "01identification identi-goation Type identification produced w- Telephone No.: Partnership 13 efom me, this &y. Of 20_ per&6nally appeared partntr/agt,ntoubehalf of a partnership, who executed the foregoing instrument and acIcnowledged before me that same was extcut.eZ,for the pi)rp o.-se;s therein express ed. Signaure., Of Notan Print Name ASHLEE, -CALLAHAN Notary Public, Stamp: Commission Expires:ASHLEE CALLAHAN A4 A� My COMMISSION # HH 295010 EXPIRES, NoveiTtber 30,2026 P age 2 of 2 VIRTUAL REVIEW ASSIST Private Provider F"lan ComMliance Affidavi) Private Provider Firm: Virtual Review Assist, Inc. Private Provider: Debra Anne Klahr, BU 1967 Address: 747 Southwest 2nd Avenue Gainesville, FL 32601 Phone: 813-391-2959 Email: lucy@virtualreviewassist.com Project: New SFT Address(s): 36412 CAMP FIRE TER I hereby certify that to the best of my knowledge and belief the plans submitted were reviewed for and are in compliance with the Florida Building Code and all local amendments to the Florida Building Code by the following affiant, who is duly authorized to perform plans review pursuant to Section 553.791, Florida Statute and holds the appropriate license or certificate: Plan Sheets 1,2.1,2.2,3,4,5,6,7.1,7.2,8,9,10,11.1,11.2,12, LI,SS,ST,SNI, SN,S3M,S4,S5,S6,DI,WP, PAI.0,PAI.1, PAI.2,PAI.3,PAI.4, PAI.5,SHI.0,SHI.1,SHI.2,SH1.3,SHI.4,SHI.5 Florida License/Registration/Certification #(s) and description: FS468 Certified Standard Plans Examiner License #: PX2300 Signature of Reviewer: 7 SWORN AND SUBSCRIBED be*e me by Debra Anne Klahr being personally known tom or having produced as identification and who being fully sworn and cautioned, state that the fo goin is true and t the est of his/her knowledge or belief ig rrec Ashlee Callahan ig e of Notary Print Name Notary Public: NOTARY STAMP BELOW My commission expires: ASHLEE CAI.WiAN My COMMISSION # HH 295,980 EXPIRES: November 30, 2026 FIRE MARSHAL #01 - Reauired Permits DATE: 7/03/2023 EXAMINER: bra Klahr PX230( Building El Inspection Only Plumbing F-1 Inspection On!j V Mechanical El Lns2ection QnI2 Electrical — Amp El Inspection Only 44 Roof J_❑ Medical Gas ❑ Fire Sprinklers El On Site Piping ❑ Fire Line ❑ Irrigation ❑ Fire Alarm [:] Potable Backflow Assembly ❑ Fire Line Bacliflow Preventer E] Irrigation Bacliflow Assembly Ej Demolition El Walk-in Cooler E] Refrigeration El Hood El Ansul El Fence/Wall E] Grease Trap E] Other r_1 Other Type Construction: I V-8 Risk Category: Occupancy Load Classification: OV""Tancy Cactory ,Residential Assembly Hazardous aliStorage Day Care/Educational nal E� FD�,Mercantile Building Use: single family townhouse Alteration Level I ❑Level 2 ❑ Level 3 1,KNew Construction ❑ Interior Finish E] Interior Remodel ❑ Exterior Remodel 0 Addition El Revision Overall Size: 18-4 X 63 Number of Stories: 2 Total Sq. Ft.: 1939 Living Area: 1541 Covered Area: 398 # of Bedrooms: 2 # of Baths: 2.5 Cost per square foot: Estimated Value: Roof T ,Ue: 91 Shingle FTile E] Metal F -1 Other Squares: 13 Zoning: Wir ,!orne Debris: nside Outside Energy Code: 405-2022 SUP Flood Zone: X Base Flood Elevation: Finish Floor Elevation: Hydrostatic Vents? In yes ------ F_ I Sq. Ft. Enclosed Space Below BFE: of Vents: Size of Vents: —] —Total Sq. In. Permanent Openings 9 Central A/C 0 Gas A/C 9 Heat Pump El Gas Heat 0 Window A/C El Electric Heat Sanitary Sewer Storm Sewer Catch Basins Potable Water Underground Fire Line Front Rear Left Right As per Approved Site Plan Comments: