HomeMy WebLinkAbout23-67475335 Eighth Street
Zephyrhills, FIL 33542
Phone: (813) 780-0020 Issue Date: 08/10/2023
;Mfiffl N UPIAW[URI-d rWURZr*T-4 a - - - - W t �m
Electrical Permit Fee
$244.75
REINSPECTION FEES: (c) With respect to Reinspection fees will comply with Florida Statute 553.80(2)(c) the
local government shall impose a fee of four times the amount of the fee imposed for the initial inspection or
first reinspection, whichever is greater, for each subsequent reinspection.
Notice: In addition to the requirements of this permit, there may be additional restrictions applicable to this property that
may be found in the public records of this county, and there may be additional permit required from other governmental
entities such as water management, state agencies or federal agencies,
accordance with City Codes and Ordinances. NO OCCUPANCY BEFORE C.O.
NO OCCUPANCY BEFORE C.O.
I VC�CTOR SIGNATURE PE f1IT OFFICE[)
fitT7EXPIRES IN 6 MONTHS WITHOUT APPROVED INSPECTION
C"c_Uj chll-'L
t�Yze '
813-780-0020 City o p yr Ini s Permit Application Fax-813-780-0021
Building Department
Date Received
Phone Contact for Permitting 68-1498
aIAII11 14a a a a a a V a I A a & & '
Owner's Name KEVIN JUERGENS Owner Phone Number 1(813)862-842n
4618 WISTERIA DR ZEPHYRHILL FL 33542 Owner's Address I Owner Phone Number
Fee Simple Titleholder Name E= AL Owner Phone Number
Fee Simple Titleholder Address
JOB ADDRESS 4618 WISTERIA DR ZEPHYRHILLS, FL 33542 LOT # 38
SUBDIVISION I WHISPERING PARCELID#1 15-26-21-0160-00000-0390
(OBTAINED FROM PROPERTY TAX NOTICE)
WORK PROPOSED NEW CONSTRF--1 ADDIALT SIGN DEMOLISH
INSTALL REPAIR
PROPOSED USE SFR COMM OTHER
TYPE OF CONSTRUCTION A BLOCK FRAME STEEL
DESCRIPTION OF WORK FROOF MOUNTED SOLAR PV SYSTEM PRIVATE PLAN REVIEW & INSPECTIONS
BUILDING SIZE 1 71 SQ FOOTAGE HEIGHT
It _x x_1IFx_x_ "t it-t'l Ar1E_1U_x,Vx It IE 4L IU VAU_"T X XX X It-VX X_X_1UVX_t 1U_XC-X_JUX1E ILA It X X C 1E It WE W_
®BUILDING VALUATION OF TOTAL CONSTRUCTION
EXELECTRICAL 1$ $40,950 AMP SERVICE x PROGRESS ENERGY 0 W.R,E.C.
®PLUMBING 1$ 1
=MECHANICAL 1$ VALUATION OF MECHANICAL INSTALLATION
®GAS 0 ROOFING SPECIALTY = OTHER
FINISHED FLOOR ELEVATIONS FLOOD ZONE AREA ®YES NO
BUILDER COMPANY
SIGNATURE REGISTERED I Y/N FEE CURREN
Address License #F_
ELECTRICIAN COMPANY AFFORDA LE SOLAR ROOF & AIR LLC
SIGNATURE THOMAS WILKISON REGISTERED Y/N FEE CURREN
Address 4914 CREEKSIDE DR CLEARWATER FL License# [ EC13004592
PLUMBER COMPANY =
SIGNATURE REGISTERED Y/N FEE CURREN =/ N
Address —1 License #
MECHANICAL COMPANY
SIGNATURE REGISTERED Y/N FEE CURREN
Address License #
OTHER COMPANY =
REGISTERED Y/N FEE CURREN
Address SIGNATURE
License #
RESIDENTIAL Attach (2) Plot Plans; (2) sets of Building Plans; (1) set of Energy Forms; R-O-W Permit for new construction,
Minimum ten (10) working days after submittal date. Required onsite, Construction Plans, Stormwater Plans w/ Silt Pence installed,
Sanitary Facilities & 1 dumpster; Site Work Permit for subdivisionsAarge projects
COMMERCIAL Attach (2) complete sets of Building Plans plus a Life Safety Page; (1) set of Energy Forms. R-O-W Permit for new construction.
Minimum ten (10) working days after submittal date. Required onsite, Construction Plans, Stormwater Plans w/ Silt Fence installed,
Sanitary Facilities & 1 dumpster, Site Work Permit for all new projects. All commercial requirements must meet compliance
SIGN PERMIT Attach (2) sets of Engineered Plans.
—PROPERTY SURVEY required for all NEW construction.
Directions:
Fill out application completely.
Owner & Contractor sign back of application, notarized
H over $2500, a Notice of Commencement is required. (A/C upgrades over $7600)
Agent (for the contractor) or Power of Attorney (for the owner) would be someone with notarized letter from owner authorizing same
OVER THE COUNTER PERMITTING (copy of contract required)
Reroofs if shingles Sewers Service Upgrades A/C Fences (Plot/Survey/Footage)
Driveways -Not over Counter if on public roadways,.needs ROW
813-780-0020 City of Zephyrhills Permit Application Fax-813-780-0021
Building Department
NOTICE OF DEED RESTRICTIONS: The undersigned understands that this permit may be subject to "deed" restrictions" which may be more restrictive
than County regulations. The undersigned assumes responsibility for compliance with any applicable deed restrictions.
UNLICENSED CONTRACTORS AND CONTRACTOR RESPONSIBILITIES: If the owner has hired a contractor or contractors to undertake work, they
may be required to be licensed in accordance with state and local regulations. If the contractor is not licensed as required by law, both the owner and
contractor may be cited for a misdemeanor violation under state law. If the owner or intended contractor are uncertain as to what licensing requirements
may apply for the intended work, they are advised to contact the Pasco County Building Inspection Division —Licensing Section at 727-847- 8009.
Furthermore, if the owner has hired a contractor or contractors, he is advised to have the contractor(s) sign portions of the "contractor Block" of this
application for which they will be responsible, if you, as the owner sign as the contractor, that may be an indication that he is not properly licensed and is
not entitled to permitting privileges in Pasco County.
TRANSPORTATION IMPACT/UTILITIES IMPACT AND RESOURCE RECOVERY FEES: The undersigned understands
that Transportation Impact Fees and Recourse Recovery Fees may apply to the construction of new buildings, change of use in existing buildings, or
expansion of existing buildings, as specified in Pasco County Ordinance number 89-07 and 90-07, as amended. The undersigned also understands, that
such fees, as may be due, will be identified at the time of permitting. It is further understood that Transportation Impact Fees and Resource Recovery
Fees must be paid prior to receiving a "certificate of occupancy" or final power release. If the project does not involve a certificate of occupancy or final
power release, the fees must be paid prior to permit issuance. Furthermore, if Pasco County Water/Sewer Impact fees are due, they must be paid prior
to permit issuance in accordance with applicable Pasco County ordinances.
CONSTRUCTION LIEN LAW (Chapter 713, Florida Statutes, as amended): If valuation of work is $2,500.00 or more, I certify that 1, the applicant,
have been provided with a copy of the "Florida Construction Lien Law —Homeowner's Protection Guide" prepared by the Florida Department of
Agriculture and Consumer Affairs. If the applicant is someone other than the "owner", I certify that I have obtained a copy of the above described
document and promise in good faith to deliver it to the "owner" prior to commencement.
CONTRACTOR'S/OWNER'S AFFIDAVIT: I certify that all the information in this application is accurate and that all work will be done in compliance with
all applicable laws regulating construction, zoning and land development. Application is hereby made to obtain a permit to do work and installation as
indicated. I certify that no work or installation has commenced prior to issuance of a permit and that all work will be performed to meet standards of all
laws regulating construction, County and City codes, zoning regulations, and land development regulations in the jurisdiction. I also certify that I
understand that the regulations of other government agencies may apply to the intended work, and that it is my responsibility to identify what actions I
must take to be in compliance. Such agencies include but are not limited to:
Department of Environmental Protection -Cypress Bayheads, Wetland Areas and Environmentally Sensitive
Lands, Water/Wastewater Treatment.
Southwest Florida Water Management District -Wells, Cypress Bayheads, Wetland Areas, Altering
Watercourses.
Army Corps of Engineers -Seawalls, Docks, Navigable Waterways.
Department of Health & Rehabilitative Services/Environmental Health Unit -Wells, Wastewater Treatment,
Septic Tanks.
US Environmental Protection Agency -Asbestos abatement.
Federal Aviation Authority -Runways.
I understand that the following restrictions apply to the use of fill:
Use of fill is not allowed in Flood Zone "W unless expressly permitted.
if the fill material is to be used in Flood Zone "A", it is understood that a drainage plan addressing a
"compensating volume" will be submitted at time of permitting which is prepared by a professional engineer
licensed by the State of Florida.
if the fill material is to be used in Flood Zone "A" in connection with a permitted building using stem wall
construction, I certify that fill will be used only to fill the area within the stem wall.
if fill material is to be used in any area, I certify that use of such fill will not adversely affect adjacent
properties. If use of fill is found to adversely affect adjacent properties, the owner may be cited for violating
the conditions of the building permit issued under the attached permit application, for lots less than one (1)
acre which are elevated by fill, an engineered drainage plan is required.
If I am the AGENT FOR THE OWNER, I promise in good faith to inform the owner of the permitting conditions set forth in this affidavit prior to
commencing construction. I understand that a separate permit may be required for electrical work, plumbing, signs, wells, pools, air conditioning, gas, or
other installations not specifically included in the application. A permit issued shall be construed to be a license to proceed with the work and not as
authority to violate, cancel, alter, or set aside any provisions of the technical codes, nor shall issuance of a permit prevent the Building Official from
thereafter requiring a correction of errors in plans, construction or violations of any codes. Every permit issued shall become invalid unless the work
authorized by such permit is commenced within six months of permit issuance, or if work authorized by the permit is suspended or abandoned for a
period of six (6) months after the time the work is commenced. An extension may be requested, in writing, from the Building Official for a period not to
exceed ninety (90) days and will demonstrate justifiable cause for the extension. If work ceases for ninety (90) consecutive days, the job is considered
abandoned.
FLORIDA JURAT (F.S. 117,
OWNER OR AGENT
Subscribed and sworn to (or affirmed be re me this
"?/X /A 4 — - - —by KEVIN NGENS—
Who is/efers n—ally known to me or has/have.Loduced
as identification.
ommi �smno �HH234�745 Notary Public
.-nil
/AA/,f_
Nam & offNotary Wed, pfinfed or stamped
Notary Public State of Florida of Florida
Steven Slagle
My Commission
HH 234745
Exp. 3/112026
sworn
Who is/are personally known to me or has/have produced
as identification.
Notary Public
C7ission log
5A)A N i tu Ltvv\
Name f Notary typecP, printed or stamped
Notary Public State of
State
of FloridaF'
Emily Kuhn
My Commission
g
iltl HH 1 04795
Exp, �3/15/2025
OF PAGES
'PROJECTDIRECTORY
DIAGRAM
PV SAFETY LABELS
ATTACHMENT PLANS
ATTACHMENT DETAILS
SAFETY PLAN
i
aMOUNTING
ANCHORFIRE
DATASHEET
ARRAY WIRING BOX DATASHEET
DISCONNECT DATASHEET
INVERTER DATASHEET
MODULE DATASHEET
SYSTEM DATASHEET
'MOUNTING SYSTEM ENGINEERING LETTER
UL 2703 CLASS A FIRE CERTIFICATION
GROUNDING AND BONDING CERTIFICATION
PROJECT DETAILS
r* , ZEPHYRHILLS, FL
33542
RESIDENTIAL
USE AND OCCUPANCY
CLASSIFICATION
ONE- OR TWO-FAMILY DWELLING
GROUP (GROUP R3)
CITY OF ZEPHYRHILLS
i,
DUKE ENERGY FLORIDA
ii
020 FFPC
i# i,�i.�iiieTiii°i°
t t r CODE
CONTRACTOR INFORMATION
CREEKSIDE r' CLEARWATER,
FL .t
1 PHONE NUMBER
iCONTRACTOR
SIGNATURE
Wisteria0
@@E�b
Map odiata C-00le
PARCEL
PV-1 SCALE: NTS
N
Band lit LAKE
w r�
T
R ADETTE
;RES LAKE B }e CITY OF
ESTATES
Zephyrhills Zephyrhills
Wesl
MOORES
C
HIGHLAND LA PARK
041 ZEPHY
PEPPER
D EL V E N
7onhvirhillk
..
CERTIFY THAT THE PV ELECTRICAL SYSTEM AND ELECTRICAL COMPONENTS ,
AND APPROVED USING THE STANDARDS CONTAINED IN THE MOST RECENT VERSION OF
VVEFLO
Chancey Rd
f'i1ap data s: �2 . g le
2 LOCALE
PV-1 SCALE: NTS
SCOPE OF WORK
THIS PROJECT INVOLVES THE INSTALLATION OF A GRID -
INTERACTIVE PV SYSTEM. PV MODULES WILL BE MOUNTED
USING A PREENGINEERED MOUNTING SYSTEM. THE MODULES
WILL BE ELECTRICALLY CONNECTED WITH DC TO AC POWER
INVERTERS AND INTERCONNECTED TO THE LOCAL UTILITY
USING MEANS AND METHODS CONSISTENT WITH THE RULES
ENFORCED BY THE LOCAL UTILITY AND PERMITTING
JURISDICTION.
r• • r � i
i � `�•i •r i � r , r
i � • ' •r • i
t r! ! r •i
r �
•i •' • • i
i•
DETAILSSYSTEM
L
'/GRID -INTERACTIVE
DESCRIPTION
PHOTOVOLTAIC
ENERGY STORAGE
rrW:11s�121s;n=AE�rsT�
. ,
11 , 1,
r
S
1(2) BRANCH OF
8',,,ARRAY
WIRING
MICROINVERTERS
(1) BRANCH OF ; Q:
MICROINVERTERS
DETAILS
(POINTINTERCONNECTION
OF
NEW SUPPLY SIDEAC CONNECTION
INTERCONNECTION I'PER
NEC 705.12(A)
m-,rrr:r�c1201240V
14)
INSIDE.,l, t,�•'i
r • r '.
DISCONNECT, 2-POLE, 60A,240VAC
_SITE DESIGN PARAMETERS
VANi `•'
�rll Iq ��IIII `II
..
CATEGORY 11
Reviewed for Code Compliance
Kevin Powell
BLS S1k PX28 1., BN4866, RP 2S
"Inspection Solutions, LLC hereby certifies
That tress pleas are in compliance
With applicable codes, and have not
Been changed, altered, or modified
By Inspections Solutions, LLC"
Digitally signed by Kevin
Kevin Powell P�""e°
Date: 2023.08.03 76:09:28
_04.11
t
i
i
i
l
�
r
i
tt%tillIl/201
�t40EL R(//,s,`,
����•�10ENSF`��?i
No W1
SA;-r
"4%NAL"ItilliEtt� .
iH15 REM HAS BEEN DIGITRtLY SIGNED A^1b SEAEEb Y
elYES MANUEZ BUR 0(R4nTE GN THE DATE ADW WT
TO THE Ofkt.
AAAMO <OA,`. OF tH,, OG lD. T AAE NOi
fA-SEED SFGNE6 ANO SEAL€D Ann THE
SiG.MaE MUST BE MiTs0 d .- ES-
Digitally signed
by Reyes Manuel
Ruiz Donate
Date: 2023.08.01
i
Reviewed for Code Compliance
Kevin Powell
BU1814, P 28 1, B 1 866, RP 2I
"Inspection Solutions, LLC hereby certifies
That these plans are in compliance
With applicable codes, and have not
Boon changed, altered, or modified
By Inspections Solutions, LLCM`
N
1 SITE PLAN
PV-2 SCALE 1" = 10'
GENERAL NOTES
i i i •
•' A I 00i .
• ' i KEYLESS ACCESS SHALL BE
PROVIDED. TO ALL DUKE ENERGY FLORIDA EQUIPMENT.
CONTRACTOR SHALL USE ONLY • 'i !
NATIONALLYBY A RECOGNIZED TESTING LABORATORY
FOR INTENDED
••
# ,ii i t
i i •'WIR #
COMPLETE• OPERATIONAL
'i i - '!i !' i i i' i ! •
rsE
0 ROADWAY
ri.i i .!# i i t ,... • I
t
>t
5 (E) MAIN SERVICE PANEL (MSP), INDOOR
(N) AC COMBINER (Cl), OUTDOOR
�J (E) UTILITY METER, OUTDOOR
P-F29843
W
UJI
tS7
F- W d
M
® <
LJL
> � (—
J
U) CQ
-J
UJI
rill
r/U/J'�I 00
V
>—
UJI
t.L I
a •
�} —)
f`�1
�yyytttEi!{B�®®
RQj,
'®dd
♦♦♦, �VyuEL
�G,ere•�\CENSF-..o ®:
•' No 88991
e°7,
ST OF
.e4`
d � •eesew••
SITE PLAN
DOC ID: 86CB62-1
DATE: 7/27/23
CREATOR: S.S.
REVIEWER:
REVISIONS
PM1-26
+ _ 45 PV MODULE
MICRO'
I
INVERTER
I t I
AA
19 iN 19IN i 81N
! � h A
BRANCH BRANCH BRANCH
L-t
! +' s+
k A
A
p3c
i —" F1-2',---PV AC DISCONNECT
e 5 ; EATON DG222NRB
, ®a
L_j_.__w/
SW1t
L_
fi0A 1,1
6
(200A MSP W/150A MCS)
(
i
f
i
LOADS
TiE3,
A
J�KWH)RR
1 UTILITY METER
i120/240V 1�, 3W
(E) ACG EG�
a
MODULES
REF,
QTY.
MAKE AND MODEL
PMAX
RTC
ISO
IMP
VOC
VMP
TEMP. COEFF. OF VOC
FUSE RATING
PMi-26
26
VSUNVSUN450-144BMH
450W
I 419W
11.52A
I 10.93A
49AV
I 41.2V
-0.1279VrC(-0.26%I°C)
20A
INVERTERS
REF.
QTY
MAKE AND MODEL
AC
GROUND
RATED
MAX OUTPUT
MAX INPUT
MAX INPUT
CEC WEIGHTED
VOLTAGE
POWER
CURRENT
CURRENT
VOLTAGE
EFFICIENCY
ENPHASE
NOT SOLIDLY
11-26
26
IQ8A-72-2-US
240V
I GROUNDED
349W
1.45A
15.OA
60V
97D%
OCPDS
REF.
OTY.
RATED CURRENT
MAX VOLTAGE
C81-2
2
20A
240VAC
C83
1
20A
240VAC
FI-2
2
50A
240VAC
SYSTEM SUMMARY
B_RANCH 1
BRANCH 2
BRANCH 3
NVERTERS PER BRANCH
9
9
8
MAX AC CURRENT
13.05A
13.05A
11.60A
VAX ACOUTPUT
3,141W
3,141W
2,792W
STC POWER
11,70OW
PTC POWER
10,884W
C CURRENT
F
38A
C POWER OUTPUT
9,074W
ED AC POWER OUTPUT
9,074W
DISCONNECTS
REF. QTY.1
MAKE AND MODEL
RATED CURRENT
MAX RATED VOLTAGE
SW1 1
EATON DG222NRB OR EQUIV,
60A
I 240VAC
PASS-THRU BOXES AND COMBINERS
EF
OTY
MAKE AND MODEL
RATED CURRENT
MAX RATED VOLTAGE
J62
i
TRANSITION BOX FOR 1 CIRCUIT
30A
240VAC / 600VOC
JB1
1
TRANSITION BOX FOR 2 CIRCUIT5A
240VAC f 600VDC
C1
1
ENPHASE IQ COMBINER 3 WI IQ GATEWAY FOR
PRODUCTION MONITORING
64A
240VAC
RAPID SHUTDOWN DEVICES COMPLIANT WITH REQUIREMENTS AS PER NEC 690.12(B)(2). PV CIRCUIT CONDUCTORS LOCATED OUTSIDE THE ARRAY BOUNDARY (DEFINED AS 3 FEET FROM THE
� l POINT OF PENETRATION INTO A BUILDING OR MORE THAN 3 FEET FROM AN ARRAY) SHALL BE LIMITED TO NOT MORE THAN 30V WITHIN 30 SECONDS OF RAPID SHUTDOWN INITIATION.
CONDUCTORS LOCATED INSIDE OF THE ARRAY BOUNDARY SHALL BE LIMITED TO NOT MORE THAN 80 VOLTS WITHIN 30 SECONDS OF SHUTDOWN.
ENPHASE SYSTEM MEETS REQUIREMENTS FOR PHOTOVOLTAIC RAPID SHUTDOWN SYSTEM (PVRSS), AS PER NEC 690.12(BX2),
A THE DC AND AC CONNECTORS OF THE ENPHASE IQ8A-72-2-US AND ARE LISTED TO MEET REQUIREMENTS AS A DISCONNECT MEANS AS ALLOWED BY NEC 690.15(D). MATING CONNECTORS
SHALL COMPLY WITH NEC 690.33.
4THE ENPHASE #Q8A-72-2-US HAS A CLASS It DOUBLE -INSULATED RATING AND DOES NOT REQUIRE GROUNDING ELECTRODE CONDUCTORS (GEC) OR EQUIPMENT GROUNDING CONDUCTORS
(EGC). THE RATING INCLUDES GROUND FAULT PROTECTION (GFP). TO SUPPORT GFP, USE ONLY PV MODULES EQUIPPED WITH DC CABLES LABELED PV WIRE OR PV CABLE.
A MICROINVERTER BRANCH CIRCUIT CONDUCTORS ARE MANUFACTURED ENPHASE Q CABLES LISTED FOR USE IN 20A OR LESS CIRCUITS OF ENPHASE IQ MICROINVERTERS. THEY ARE ROHS,
OIL RESISTANT. AND UV RESISTANT, THEY CONTAIN TWO 12 AWG CONDUCTORS OF TYPE THHN -2 DRYNVET AND CERTIFIED TO UL 3003 AND UL 9703,
,pp�� ALL METAL ENCLOSURES, RACEWAYS, CABLES AND EXPOSED NONCURRENT -CARRYING METAL PARTS OF EQUIPMENT SHALL BE GROUNDED TO EARTH AS REQUIRED BY NEC 250.4(B) AND
/"\ PART III OF ARTICLE 250 AND DC EQUIPMENT GROUNDING CONDUCTORS SHALL BE SIZED ACCORDING TO NEC 690.45. THE GROUNDING ELECTRODE SYSTEM SHALL ADHERE TO NEC 690.47(A)
AND NEC 250.169 AND INSTALLED IN COMPLIANCE WITH NEC 250.64.
2 {� � MAX DC VOLTAGE OF PV MODULE IS EXPECTED TO BE 53.2V AT -5-C (4.9-C - 25-C) X -0.128VIC - 49AV = 53.2V).
AC AGGREGATION PANEL BUSBAR AND THE OVERCURRENT PROTECTION PROTECTING THE BUSBAR SHALL BE SIZED IN ACCORDANCE WITH NEC 705.12(B}(2)(3xC).
THE ENPHASE 10 COMBINER 3 CONTAINS A FACTORY -INSTALLED COMMUNICATIONS GATEWAY WITH AN OCPD RATED NO MORE THAN 20A
} PV SYSTEM AC DISCONNECT SHALL BE A VISIBLE KNIFE -BLADE TYPE DISCONNECT THAT IS ACCESSIBLE AND LOCKABLE BY THE UTILITY. THE DISCONNECT SHALL BE LOCATED WITHIN 10 FT
//��
OF UTILITY METER. DISCONNECT SHALL BE GROUPED IN ACCORDANCE WITH NEC 230.72.
A PV SYSTEM AC DISCONNECT MEETS NEC 690.12(C) REQUIREMENT FOR A RAPID SHUTDOWN INITIATION DEVICE
POINT -OF -CONNECTION IS ON THE SUPPLY SIDE OF SERVICE DISCONNECT, INSIDE PANELBOARD ENCLOSURE USING UNUSED TERMINALS, TERMINALS THAT ARE SUITABLE FOR DOUBLE
A LUGGING, OR USING OTHER LOCALLY -APPROVED METHODS AND HARDWARE, IN COMPLIANCE WITH NEC 705.12(A). THE PANELBOARD SHALL HAVE SUFFICIENT SPACE TO ALLOW FOR ANY
TAP HARDWARE AS REQUIRED BY NEC 110.3 AND NEC 312A(A)
CONDUCTOR AND CONDUIT SCHEDULE W/ELECTRICAL CALCULATIONS
CURRENT -CARRYING
MAX.
TERM.
AMP.@7
ID
TYP
CONDUCTOR
CONDUIT i CABLE
CONDUCTORS IN
OCPD
EGC
TEMP.CORR.
FILL FACTOR
CONT.
CURRENT
BASE AMP,
DERATED
TEMP.
TERM.
LEN. V.D.
CONDUITICABLE,
FACTOR
CURRENT
(125%)
AMP
RATING
TEMP
RATING
1
2
12 AWG IN
CABLE
2
20A
6 AWG BARE, COPPER
0.71 (57-C)
1.0
13.05A
16.31A
30A
21.3A
90°C
30A
118A FT 1.27%
0 CABLE, CO
ENPHASE Q CABLE, COPPER
2
1
12 AWG
CABLE, COP N
CABLE
2
20A
6 AWG BARE, COPPER
071 (57-C)
f .0
11.6A
14SA
30A
21.3A
90°C
30A
52.5FT I D%
ENPHASE Q CABLE, COPPER
0
3
2
1 10 AWG THWN-2, COPPER
0.75- CIA LFMC
4
20A
10 AWG -2, COPPER
0.76 (5FC)
0.8
13.05A
16.31A
40A
24.32A
90°C
40A
3OFT 0.2%
4
1
1O AWG THWN-2, COPPER
0]5" DIA. LFMC
2
20A
10 AWG THWN-2, COPPER
0,76 (55-C)
1.0
11.6A
14.5A
40A
30.4A
90°C
40A
28.8FT 0.35%
5
1
6 AWG THWN-2, COPPER
0.75° DIA PVC-40
3
50A
6 AWG THWN-2, COPPER
0.96(
1.0
37.7A
47.13A
75A
72A
I
75-C
65A
48IN 0.06%
6
1
6 AWG THWN-2, COPPER
0.75' DIA. PVC 40
3
50A
NIA
0,96 (35`C)
1 A
37.7A
47.13A
75A
72A
75-C
65A
481N I 0.06%
Reviewed
Kevin Powell
U1 14, P 2 41, BN4866, RPX329
"Inspection Solutions, LLC hereby certifies
That these laps are in compliance
With applicable codes, and have not
Been changed, altered, Or modified
y Inspections Solutions, L LC"
l
REQUIREMENTS'ALL EQUIPMENT SHALL BE
PROPERLY GROUNDED PER THE
OF ARTICLES
i& >•
IWHEN
i � Y
i WITH PROPOSED RV
!i
;IF THE EXISTING MAIN SERVICE
PANELDOES NOTY k
iVERIFIABLE GROUNDING
ELECTRODE,
INSTALL A SUPPLEMENTAL
iELECTRODE CONDUCTOR (GEC)
AC SYSTEM GROUNDING
I SHALL BE
A MINIMUM SIZE #8AWG
INSULATED, #6AWG IF «Y>
IWI
E.
EQUIPMENT ! GROUNDING
CONDUCTORS k�11 i
ACCORDING TO NEC ARTICLE 9
k D BE k MINIMUM OF Ek
• •OSED TO DAMAGE,
HALL BE i WHEN
�EXPOSED TO DAMAGE
'GROUNDING Ti BONDING
CONDUCTORS, IF INSULATED, SHALL
BE COLOR CODED GREEN, OR
MARKED GREEN IF #4AWG OR
LLARGER
i
i'
i"
i
i,
yk��•��CEL
OF r'z-:
Digitally signer#
•
PROJECT! 86CB62-1
DATE 7/27/23
CREATED :
CHECKED
0 1
SCALE: NTS
i
MAIN SERVICE PANEL C}(1), FFPC 11.12.2.1.1.1.1, AND FFPC
AC COMBINER PANEL (Cl)
NEC 705.12(B)(2)(3)(C)
POINT -OF -INTERCONNECTION OR AT MAIN SERVICE DISCONNECT (MSP, LIM)
1 CAUMN !
POWER TO THIS BUILDING IS ALSO SUPPLIED FROM ROOF -MOUNTED SOLAR ARRAYS WITH SAFETY
DISCONNECTS AS SHOWN
SOLAR R Y \ I
4618 WISTERIA DR ZEPHYR
NEC 690.56(B) AND NEC 705A0
DILLS • INSTALLED BY AFFORD -ABLE SOLAR ROOF & AIR'
ME
t a � t t � • • ♦'
• 't t t t
• •i
•• • •
i t t • t PLUNNUM
LABELING
• k! i i is r i
Ulm
i «• i i
< i ! i i<•i
f
i ! •
i i <
i
•! i
! � is •! i
Reviewed for Code Compliance
Kevin Powell
BU1814, P S41, B I4SB a, RP B 9
"Inspection Solutions, LLC hereby certifies
That these plans are Ire compliance
With applicable codes, are have riot
Begirt changed, altered, ter modifiCM,
BY Inspections Solutions, LL
i t f
Reviewed for Code Compliance
Kevin Powell
BU1814, P S41, B I4SB a, RP B 9
"Inspection Solutions, LLC hereby certifies
That these plans are Ire compliance
With applicable codes, are have riot
Begirt changed, altered, ter modifiCM,
BY Inspections Solutions, LL
i t f
A
i
.r
i
i
•
s�
1i
®�'titie�era�®`B'o
.`
t1EL R2
(t` �d
Oi6♦ I
.: No 991
0
�-o OF
i1 PA RA
STRUCj•y METERS
'WIN• •I
III n �• p l I
.•"II CATEGORY
RISK CATEGORY
•OOF • i
TIES
MATERIAL
®
SHINGLE (1 LAYER)
COMPOSITION
I'•• ■_
a tom.
ROOF DECKING
•
MECHANICALMODULE PROPERTIES
•���■■.VSUN
l i
MOUNTING SYSTEM PROPERTIES
/tR•'�. • c1Ri4'itII'
4000162, r
2O INCH EMBEDMENT INTO TRUSSES
GROUNDING AN-
BONDING•
•• •
t - •
DEAD LOAD CALCULATIONS
;ai I. II
• a I
�
,� • �.. nlrrlll�ILtll�llllllll,���.
r
a � / 1. • ..���
TOTAL ARRAY
• er" � 1
•
! Ili. • + ♦ • a
�• •`�
FIT
LOCATIONS ARE APPROXIMATE. ANCHORS MAY
FASTENEDTRUSS
BE TOD• IN NO CASE
SHALL•• SPACINGANCHOR
V
SPACING"
❑�a
"Inspection
That these pleas are in compliance
With applicable codes, and have not
Geer charged, altered, or modified
y Inspections Solutions, Imp s.
RIDGE
ANCHOR PLACEMENT PARAMETERS (ASCE 7-16)
•j�n
I MAX. ALLOWABLEIR_=161il
RAIL SPAN
I •
•
•-
,�>A�
alp �
��
Fi�•Ri'c13cTE�
ICI �t
Ir P
y
�R(�� III
EAVE
• + •
a = MAX(MIN(0.4 * MEAN ROOF HEIGHT, 0.1 * LHD), 0.04 * LHD, 3 FT)
4A FT = MAX(MIN(0.4 * 11.5 FT, 0.1 * 44.1 FT), 0.04 * 44.1 FT, 3 FT)
EDGE MODULES = DISTANCE TO ROOF EDGE < 2 * (AIR GAP + MODULE THICKNESS)
8.0 IN = 2 * (2.6 IN + 1.38 IN)
1
•
J
•
1
I
SM&
STRUCTURAL PARAMETERS
IWIND a II I t
« ,GORRISK CATEGORYXPOSURE
ROOF PROPERTIES
ROOF MATERIAL
COMPOSITIO■
®,
;1
l �il`�I lou'I
't i 1111111
OSB
MODULE MECHANICAL PROPERTIES
111,T0111:1 ®
t
�t
211TV410121�®
16%11.14*
MOUNTING PROPERTIES
,,
K2 4000162, r
{{.III
iEMBEDMENT t 'U1fCSA
FASTENING t#
i' ! . DI
GROUNDING
i'BON# I #
�I111,1:411 Im I m ii
KILIIV 401111
• I
TRUSS LOCATIONS . APPROXIMATE. ANCHORS -MAY
BE FASTENED TO DECKING WHERE NEEDED. O CASE
SHALLi. SPACING# t.
• y
❑a
RM
•. y CEMENT PARAMETERS
ys yi.. (ASCE
ANCHOR
..
IN# PRESSURE
ZONE
'i! ! ■!I II ■I
i a
MAX, Ial■7^t ItRII !'MAX
I I I ■
ALLOWABLE
•
Reviewed for Code Compliance
Kayla Powell
BU181 :, PX2841, BN BSI, RP 32
"Inspection Solutions, LLC hereby certifies
That these plans are in compliance
With applicable codes; and have not
Beery charged, altered, or modified
By Inspections Solutions, LLU
OF 'ti t a # # t'
a = MAX(MIN(0.4 * MEAN ROOF HEIGHT, 0.1 * LHD), 0.04 * LHD, 3 FT)
4A FT = MAX(MIN(0.4 * 11.5 FT, 0.1 * 44.1 FT), 0.04 * 44.1 FT, 3 FT)
EDGE MODULES = DISTANCE TO ROOF EDGE < 2 * (AIR GAP + MODULE THICKNESS)
8.OIN=2*(2.6IN+1.38IN)
Illl.� l lll�llll 1, ill lf* � �1
i
i .
i
s
f#
o 88991
1
• t
• '
I
y
I
I
i
ATTACHMENT PLAN
!t ! 86CB62-1
DATE: 23
11■I
IIIIIIIIIII III ill
STRUCTURAL DESIGN PARAMETERS
1�
WIND (ASCE 7-16)
145 MPH, EXPOSURE CATEGORY B,
RISK CATEGORY 11
ROOF PROPERTIES
ROOF MATERIAL
COMPOSITION SHINGLE (I LAYER)
ROOF DECKING
TRUSSES (2X4 TOP -CHORD), 241N OC
MODULE MECHANICAL PROPERTIES
�,i�,��'—Vsuwv-SUN450-144BMH
--- ---- ---
83.01N X 41.31N X 1AIN (23.8 SO FT)
MOUNTING SYSTEM PROPERTIES
K2 CROSSRAIL 44-X
K2 4000162,2.61N AIR GAP
[FASTENING METHOD
2.0- INCH EMBEDMENT INTO TRUSSES
OR DECKING WITH (2-4) 3/161N DIA,
�FASTENERS
GROUNDING AND
BONDING
DEAD LOAD CALCULATIONS
�_MICROINVERTERS
I TOTAL ARRAY WEIGHT
�E Hall
1 TRUSS LOCATIONS ARE APPROXIMATE. ANCHORS MAY
BE FASTENED TO DECKING WHERE NEEDED. IN NO CASE
SHALL THE ANCHOR SPACING EXCEED -MAX. ANCHOR
SPACING'
Me a
MT�VM T wVVr;'1 EAVE
3U1914, PX2841, BN4866, RPX329
"Inspection Solutions, LLC her certifies
That these plans are in compliance
With applicable codes, and have not
Been changed, altered, or modified
By Inspections Solutions, LLU
ANCHOR PLACEMENT PARAMETERS (ASCE 7-16)
MAX, ALLOWABLE
RAIL SPAN
a = MAX(MIN(0.4 * MEAN ROOF HEIGHT, 0.1 * LHD), 0.04 * LHD, 3 FT)
4.4 FT = MAX(MIN(0.4 - 12.9 FT, 0.1 - 44.1 FT), 0b4 44.1 FT, 3 FT)
EDGE MODULES = DISTANCE TO ROOF EDGE < 2 (AIR GAP + MODULE THICKNESS)
8.0 IN = 2 * (2,6 IN + 138 IN)
Or
W-F WSCALE: 3116' = V
jai
21
on
jjJ11111111 I
EL.R
E S
No 8 991
F
< x,
N
M_�z I �& W,
STRUCTURAL PARAMETERS
145 MPH, EXPOSURE CATEGORY B,
RISK CATEGORY 11
i PROPERTIES
IF
ROOF MATERIAL
I
COMPOSITION SHINGLE (I LAYER)
`t# NIXONl�5168
t
MODULE MECHANICAL PROPERTIES
MODEL
VSUN VSUN450-144BMH
DIMENSIONS (AREA)
83.01N X 41.3IN X 1 AIN (23.8 SO FT)
WEIGHT
53.8 LBS
MOUNTING SYSTEM PROPERTIES
CROSSRAIL
K2 4000162,
FASTENING METHOD
f
#• �, #
GROUNDING AND
BONDING
DEAD LOADY •
iililiii���
� ��
■�!
TOTAL.:
>: ...E .: : !
: •"
FASTENEDTRUSS LOCATIONS ARE APPROXIMATE, ANCHORS MAY
TO DECKING WHERE NEEDED. IN NO CASE
ANCHORSHALL THE SPACING r ', ANCHOR
SPACING-
Ing
1.1111NO
-• ",-
tt #MAK
ALLOWABLE•-
t _•
s#
t
"In,spection Solutions, LLC herebycertifies
That these plans arein compliance
With applicable cores, and have not
Been changed, altered, , or modified
By Inspections Solutions, LLU
a = MAX(MIN(0.4 * MEAN ROOF HEIGHT, 0.1 * LHD), 0.04 * LHD, 3 FT)
4.4 FT = MAX(MIN(0.4 * 12.9 FT, 0.1 * 44.1 FT), 0.04 * 44.1 FT, 3 FT)
EDGE MODULES = DISTANCE TO ROOF EDGE < 2 * (AIR GAP + MODULE THICKNESS)
8.0 IN = 2 * (2.6 IN + 1.38 IN)
•
i'-
i
•f
t
s
WMA
• j PARAMETERS
STRUCTURAL
i WIND (f •)
145 MPH, EXPOSURE ' GO
RISK CATEGORY
'f�: � �f fff
1 •
R#.O, PROPERTIES
•ff 1 ,,
COMPOSITION SHINGLE (1 LAY
115/32'OSB
f f .
- f- ••i f
i RO
I
llt1i1t1#��sS�#Ilt+7[:1i1�
i # - i f
j it UNTING SYSTEM ii
iceTIES
K2 CROSSRAIL
ANCHOR MODEL K2 4000162,2.61N AIR GAP
FASTENING UIIIIII � � i : � •• - i
-f i �� 1 •f # i
W,# !
DEAD LOADCALCULATIONS
TOTAL ARRAY WEIGHT 1255.2 LBS
f�
TRUSS LOCATIONS ARE APPROXIMATE. ANCHORS MAY
-.... FASTENED O D' NEEDED.
SHALL ANCHOR SPACING. EXCEED"MAX.
ANCHOR
SPACING"
,•., f � i •f ff
Reviewed for Code
Kevin Powe
BU18, PX2841£ BN4,
"Inspection Solutions, LLC hereby certifies
That these plans are in compliance
With applicable cO, and have not
Been changed, altered, Or modified
By Inspections Solutions, LL '
ANCHOR PLACEMENT PARAMETERS
W—Mg
MAX, ALLOWABLE WZ 11161
MAX. ALLOWABLERAIL
f
•
SPAN
CANTILEVER
0
9=1
f `ff f f if'
• . f•f � •f i is . #
a = MAX(MIN(0.4 * MEAN ROOF HEIGHT, 0.1 * LHD), 0.04 * LHD, 3 FT)
4A FT = MAX(MIN(0.4 * 12A FT, 0.1 * 44.1 FT), 0.04 " 44.1 FT, 3 FT)
EDGE MODULES = DISTANCE TO ROOF EDGE < 2 * (AIR GAP + MODULE THICKNESS)
8.0IN=2*(2.6IN+1.38IN)
r
OWN
SCALE:4
•
•
•
•
•
■
tAUEL•RU�Z `®,®
fiC., .-*'\CEASF-.`OIL
c No P991
®OAF. 'r� C) R t C83 p�••'`�k.®:
t
s
i ( DESIGN PARAMETERS
STRUCTURAL
�Tw�� I �rw t
1 I 1
• # CATEGORY
CATEGORYRISK
ROOF
Q.t.Tsnti�:m�-PROPERTIES---•
MODULE MECHANICAL PROPERTIES
MOUNTING SYSTEM PROPERTIES
MOUNTING SYSTEM PROPERTIES
�l�t)j#�:illi�ll��lllllf®:.K2
4000162, r
FASTENING«r
#' rECKING WITH (24) 31161N r
GROUNDING rINTEGRAL
BONDING
GROUNDINGr
# UL 2703
DEAD LOAD CALCULATIONS
IIII IIII IIII III
j TOTAL ARRAY WEIGHT
r #=r R #
ANCHOR'SHALL THE •. r «R
SPACING"
.• # a
COMPLIANCE I
K
ANCHORPLACEMENTPARAMETERS ySCE `...
WIND RR
it r «MAX.
ANCHOR
«
#
•#
i���11
for Code Compliance
Kevin Powell
PX2841,BN4866,RPX329
If ibPCa. L11JaI so,utionS, LLB. "ereby ce, Lit E ss.
That these pleas are in compliance
With applicable codes, and have not
Been changed, altered, or modified
By Inspections Solutions, LLC
FT, THESE SETBACKS ARE APPLIED TO THE BUILDING FOOTPRINT AND PROJECTED TO THE ROOF
PLANES IN ACCORDANCE WITH GUIDANCE'« i r : • FIGURES 30.3-213-1.
a = MAX(MIN(0.4 * MEAN ROOF HEIGHT, 0.1 * LHD), 0.04 * LHD, 3 FT)
4.4 FT = MAX(MIN(0.4 * 12.1 FT, 0.1 * 44.1 FT), 0.04 * 44.1 FT, 3 FT)
EDGE MODULES = DISTANCE TO ROOF EDGE < 2 * (AIR GAP + MODULE THICKNESS)
8.0IN=2*(2.6IN+1.38IN)
1 1 - j i t i
• ` j j 7
i
•
i!♦
%®�tttitlt7BBI
ENSFR.02
r^a S OF -
'o�SS It
Reviewed for Code Compliance
Kevin Powell
BU1814,PX2841,8N4866,RPX329
"Inspection Solutions, LLC hereby certifies
That these plans are in compliance
With applicable codes, and have not RAIL CLAMPING ZONE
Been changed, altered, or modified
By Inspections Solutions, LLC
MOUNTING SYSTEM NOTES
®
1 i 4> f #>#i. i #
IF THERE IS ANY CONFLICT BETWEEN WHAT IS DEPICTED HERE AND INSTRU
PROVIDED BY A MANUFACTURER, THE MANUFACTURER'S INSTRUCTIONS SHALL
ISUPERCEDE.
ROOF FRAMING
K2 SYSTEMS
END CLAMP
PV MODULE K2 SYSTEMS
PV MODULE CROSSRAIL 44-X
A PV-6 K2 SYSTEMS
SPLICE FOOT XL
W/ K2 EVERSEAL.
B COMP. SHINGLE
PV ROOFING
-6 ROOF UNDER Y ENT
ROOF DECKING ROOF FRAMING
LAG/STRUCTURAL SCREWS
EMBEDDED INTO ROOF FRAMING
4 A RACKING ELEVATION TRANSVERSE VIEW (—C--� ATTACHMENT DETAIL (TRANSVERSE VIEW)
C PV-6 VALE: NTS SCALE: NTS
PV MODULE
K2 SYSTEMS K2 SYSTEMS K2 SYSTEMS
END CLAMP K2 SYSTEMS CROSSRAIL 44-X
MIDCLAMP PV MODULE SPLICE FOOT XL
K2 SYSTEMS W
CROSSRAIL 44-X / K2 EVERSEAL
COMP. SHINGING LE COMP. SHINGLE
�"A ROOFING
ROOF
ROOF DECKING
ROOF FRAMING
ROOF UNDERLAYMENT
ROOF FRAMING SPACING ATTACHMENT SPAN ROOF DECKING LAG/STRUCTURAL SCREWS
EMBEDDED INTO ROOF
ROOF FRAMING FRAMING
RACKING ELEVATION (LONGITUDINAL VIEW D ATTACHMENT DETAIL (LONGITUDINAL VIEW)
�\PV-6 ) SCALE: NTS \P SCALE: NITS
a
•
•
ComplianceReviewed for Code
<
Kevin Powell'
BU1814, P2541, BN4866, RPX329
"Inspection
That theli
With appi
Been ca
1 FIRE SAFETY PLAN
PV-7 SCALE: 1• =1Q'
GENERAL NOTES
- :l
i i t •`t i
'tt ..t i •. t ! t..t.
•i `lt • i t
ti `t i `• i •••
i i
`!i ' + '! t•i
••! i i ! i i
+ i +t `tt •+
+ i i
i
I
: '!! iTYIN ••
Bill
■_! 1 i l i # !• • i
O ROOF ACCESS POINT
O ROADWAY
r 101 1!
MODULESPV D ON ROOF WITH K2 CROSSRAIL
MOUNTING
3.0'WIDE FIRE ACCESS PATHWAY, PER FFPC
04.5'WIDE FIRE ACCESS PATHWAY,
REQUIREMENTS'
BUILDINGi•GROUP R3
j !
r #
#• i i
' •' # i ' i "#
P-F29843
W
CN
U
U-)
i.0
coU3
® <
J
U) IY
U) L
—J
®
ui
M
pui
V
uj
UJI
mt``{rrrrry'®
PjyUEL RU>2
®•�`� `*\CENsj-..0rim
®�.• S E OF
.•`Q7.
O `•. �� O R Ip �`.••�
FIRE SAFETY PLAN
DOC ID: 86CB62-1
DATE: 7/27/23
CREATOR: S.S.
REVIEWER:
REVISIONS
Customized for VAN METER
VSUN450-144BMH
4500"W VSUN440-144BMH
Highest
f^fo%An ro%rn li-mna-An
!gHeSL powelibuty-na r
Kevin Powell
BU1814, PX2941, BN4866, RP
2 3 7
U• Iection Solutions, LLC hereby Certifies
That these plans are in Compliance
Module efficiency With applicable codes, and have not
25yearS Been changed, altered, or modified
By Inspections Solutions, LLC"
Material & Workmanship warranty
Integrated
Wire Management
ye PS
Linear power output warranty
loop/.
97% Additional value from VSU
9OP/0 near Warranty
Number ol'years 10years 15 years 20 years 25 years 30 years
0 VSUN 0 Standard Warranty
Munich RE
PERC Cell Technology
PE R
Z)
Higher output power
V a Lower risk of micro -crack
Positive tolerance offer
tPLower
risk of hot spot
Better shading tolerance
IEC61215 & IEC61730
UL61730 certificate
Certified for salt/ammonia
corrosion resistance
Lower LCOE
VSUN, a BNEF Tier-1 PV module manufacturer invested by Fuji Solar, has been committed
to providing greener, cleaner and more intelligent renewable energy solutions. VSUN is
dedicated to bringing reliable, customized and high -efficient products into various
markets and customers worldwide
ldr%
PV CYCLE
00- C E on
Electrical Characteristics at Standard Test Con ditions(STC)
Module Type
VSUN450-144BMH VSUN445-144BMH VSUN440-1448MH VSUN435-144BMH
Maximum Power - Pmax (W)
450 445 440 435
Open Circuit Voltage - Voc (V)
49A 49.2 49 488
Short Circuit Current - Ise (A)
11.52 11A4 1136 11.28
Maximum Power Voltage - Vmpp (V)
41.2 41 40,8 40.6
Maximum Power Current - Impp (A)
10.93 10.86 1039 10.72
Module Efficiency
20.37% 20.14% 19.92% 19.69%
Standard Test Conditions (STQ: irradiance 1,000
W/M2; AM 1,5; module temperature 25°C. Pmax Sorting: 0-5W. Measuring Tolerance: ±3%.
Remark: Electrical data do not refer to a single module and they are not part of the offer. They only serve for comparison among different module types.
Electrical Characteristics with different rear side power gain(reference to 44S front)
Pmax (W) Vac (V)
Isc (A) Vmpp (V) Impp (A) Pmax gain
468 49.2
12.01 41 11.40 5%
490 492
12.58 41 11.95 10%
533 49.30
13,73 40.90 1103 201/.
555 49.30
14.30 40.90 13.58 25%
Temperature Characteristics Maximum Ratings
NOCT
45`C(±2°C) Maximum System Voltage [VI 1500
Voltage Temperature Coefficient
-0.26-/.`/"C Series Fuse Rating [A) 20
Current Temperature Coefficient
+0.0541/./*C Bifaciality 701/.±10%
Power Temperature Coefficient
-0.32/./-C
Material Characteristics
Dimensions (L*W*H)
2108 x 1048 x 35mm 82.9 x 41.26 x 1.38 inches
Weight
24.4kg / 53.79lbs
Frame
Black anodized aluminum profile
Front Glass
AR -Coating toughened glass, 3.2mm
Cell Encapsulation Back
EVA or POE
Sheet
Transparent black -mesh backsheet
Celts
12 -12 pieces bifacial monocrystalline solar cells series strings
Junction Box
IP68,3 diodes
Cable&Connector Wire
Cable length 2400 mm, Staubli MC4 connector
Management
Wire management system fits 6.1-6.7 mm OD wires including Solaredge and Enphase Cables
Packaging
System Design
Dimensions (L*W*H)
2140*1125*1181mm Temperature Range -40 *C to + 85 'C
84.25*44.29*46.50 inches Withstanding Hail Maximum diameter of 25 mm with
Container 20'
155 impact speed of 23 m/s
Container40'
341 Maximum Surface Load 5,400 Pa
Container 40'HC
682 Application class class A
Notemm (inch)
FRONT VIEW
BACK VIEW
A -A
Frame
11(0.43)
6.1-6.7 m. wire
(0.24-026 inch)
Z
44
aw
V.I.VN
E ... Hp,lf ........ nd,, k tight—diti-
Rlwi—d—.Wa4x
n. ENPHASE, IQ8 M and 1Q8A Microinverters
Our newest 108 Microinverters are the industry's first microgrid-forming, software defined
microinverters with split -phase power conversion capability to convert Do power to AC
power efficiently. The brain of the semiconductor -based microinverter is our proprietary
application specific integrated circuit (ASIC) which enables the microinverter to operate in
grid -tied or off -grid modes. This chip is built in advanced 55nm technology with high speed
digital logic and has superfast response times to changing loads and grid events, alleviating
constraints on battery sizing for home energy systems.
Part of the Enphase Energy System, IQ8
Series Microinverters integrate with the
10 Battery, IQ Gateway, and the Enphase
App monitoring and analysis software.
Connect PV modules quickly and easily
to IQ8 Series Microinverters using the
included Q-DCC-2 adapter cable with
plug-n-play MC4 connectors.
when installed with 10 System Controller 2, meats UL 1741.
108M and 1Q8A support spilt -phase. 240V installations only.
IQ8 Series Microinverters redefine
reliability standards with more than one
million cumulative hours of power -on
testing, enabling an industry -leading
limited warranty of up to 25 years.
108 Series Microinverters are UL listed
as PV Rapid Shutdown Equipment and
conform with various regulations, when
installed according to manufacturer's
instructions.
eviewed for G
Kevin
BU2841
Witt
le Compliance
Module compatibility
well
MPPT voltage range
Operating range
44866,RPX329
Min,/ Max, start voltage
IC hereby certifies
Max. input DC voltage
a in compliance
�s, and have not
Max, continuous input Do current
Been changed, altered, or modified Max. input DC short-circuit current
By Inspections Solutions, LLC Max. modulel_
Overvoltage class DC port
DC port backfeed current
PV array configuration
Easy to install
Lightweight and compact with plug-n-
play connectors
Power Line Communication (PLC)
between components
Faster installation with simple two -wire
cabling
High productivity and reliability
Produce power even when the grid is
down*
More than one million cumulative hours
of testing
Class It double -insulated enclosure
Optimized for the latest high-powered
PV modules
Microgrid-forming
Complies with the latest advanced grid
support —
Remote automatic updates for the
latest grid requirements
Configurable to support a wide range
of grid profiles
Meets CA Rule 21 (UL 1741-SA) and IEEE
1547.2018 (UL 1741-SB 31d Ed.)
Note"
IQ8 Microinverters, cannot be mixed together with
previous generations of Enphase microinverters (107
Series, 106 Series. etc) in the same system,
0 2022 Enphase Energy. All rights reserved. Enphase, the Enphase logo, 108 Microinverters,
and other names are trademarks of Enphase Energy, Inc. Data subject to change. MMA-12A-DS-0069-03-EN-L)S-2022-12-27
W 260-460 295-500
54-cell / 108 half -cell, 60-cell / 120 half -cell, 66-cell / 132 half -cell and 72-cell / 144 half -cell
V 30-45 32-45
V 16-58
V 22/58
V 60
A 12
A 25
A 20
ffA 0
1 x 1 Ungrounded array; No additional DC side protection required; AC side protection requires max 20A per branch circuit
Peak output power
VA
330
366
Max. continuous output power
VA
325
349
Nominal (L-L) voltage/ range2
V
240 /211- 264
Max. continuous output current
A
1.35
L45
Nominal frequency
Hz
60
Extended frequency range
Hz
47-68
AC short circuit fault current over
2
3 cycles
Arms
Max. units per 20 A (L-L) branch circuit3
11
Total harmonic distortion
<51Y.
Overvoltage class AC port
fit
AG port backfeed current
ink
30
Power factor setting
1.0
Grid -tied power factor (adjustable)
0.85 leading - 0.85 tagging
Peak efficiency
%
97.8
973
CEC weighted efficiency
%
97,5
97
Night-time power consumption
mw
ii
60
NZM=:`ii EEN=
Ambient temperature range
-40'C to -60'C (-40'F to +14TF)
Relative humidity range
4% to 100% (condensing)
DC Connector type
MCA
Dimensions (H x W x D)
212 mm (8.3") x 175 mm (6.91 x 30.2 mm (1.2")
Weight
L08 kg (2,38 lbs)
Cooling
Natural convection - no fans
Approved for wet locations
Yes
Pollution degree
PD3
Enclosure
Class 11 double -insulated, corrosion resistant polymeric enclosure
Environ. category / UV exposure rating
NEMA Type 6 / outdoor
CA Rule 21 (UL 1741-SA), UL 62109-1, IEEE 1547.2018 (UL 1741-SB 3v Ed,), FCC Part 15 Class B, ICES-0003 Class 6, CAN / CSA-C22.2 NO, 107.1-01
Certifications This product is UL Listed as PV Rapid Shutdown Equipment and conforms with NEC 2014, NEC 2017, and NEC 2020 section 690.12 and C221-
2018 Rule 64-218 Rapid Shutdown of PV Systems. for AC and DC conductors. when installed according to manufacturer's instructions.
(1) Pairing PV modules with wattage above the limit may result in additional clipping losses. See the compatibility calculator at
https://Iink,enphase.com/module-compatibility. (2) Nominal voltage range can be extended beyond nominal if required by the utility.
(3) Limits may vary. Refer to local requirements to define the number of microinverters per branch in your area, IMMA-12A-DS-0069-03-EN-US-2022-12-27
Reviewed for Code Compliance
Kevin Powell
BU1814,PX2841,BN4866,RPX329
"Inspection Solutions, LLC hereby certifies
Enphase Networking
That its plans are in compliance
With applicable codes, and have not
Been changed, altered, or modified
By InsperAions Solutions, LLC'
E n p, 'n" a s e
The Enph,,ase M Combine,- 3" with Enphase
IQ Envoy" consolidates interconnection
, Ciner,33
,,,, %____1 1,3-
Homb
equipment into a single enclosure and
(X-IQ-AM1-240-3)
streamlines PV arid storage Installations by
providing a consistent, pre -wired SOILItiOrl for"
residential applications. It offers LIP to four
2-pole input circuits and Eaton BR series
busbar assembly.
Includes IQ Envoy for communication
and control
Flexible networking supports Wi-Fi,
Ethernet, or cellular
Optional AC receptacle available for PLC
bridge
Provides production metering and optional
consumption monitoring
Reduced size from previous combiner
Centered mounting brackets support single
stud mounting
Supports back and side conduit entry
Up to four 2-pole branch circuits for 240 VAC
plug-in breakers (not included)
80 A total PV or storage branch circuits
Durable NRTL-certifted NEMA type
3R enclosure
Five-year warranty
UL listed
LISTED
To learn more about Enphase offerings, visit enphase.com
!=�ENPHASE
%-d'
Enphase IQ Combiner 3
MODEL NUMBER
ACCESSORIES and REPLACEMENT PARTS (not included, order separately)
Consumption Monitoring' CT
CT-200-SPLIT Split core current transformers enable whole home consumption metering (+/- 2,5%).
EPLC-01 Power line carrier (communication bridge pair), quantity 2
XA-PLUG-120-3 Accessory receptacle for Power Line Carrier in IQ Combiner 3 (required for EPLC-01)
XA-ENV-PCBA-3 Replacement [Q Envoy printed circuit board (PCB) for Combiner 3
ELECTRICAL SPECIFICATIONS
Rating Continuous duty
System voltage 120/240 VAC, 60 Hz
Max. continuous current rating (output to grid) 65A
Max. fuse/circuit rating (output) 90A
Branch circuits (solar and/or storage) Up to four 2-pole Eaton BR series Distributed Generation (DG) breakers only (not included)
Max, continuous current rating (input from PV) 64A
Max, total branch circuit breaker rating (input) 80A of distributed generation / 90A with IQ Envoy breaker included
MECHANICAL DATA
Weight T5 kg (16,5 lbs)
Ambient temperature range -401 C to +460 C (-400 to 1150 F)
Cooling Natural convection, plus heat shield
Wire sizes
20 A to 50 A breaker inputs: 14 to 4 AWG copper conductors
60 A breaker branch input: 4 to 1/0 AWG copper conductors
Main lug combined output: 10 to 2/0 AWG copper conductors
Neutral and ground: 14 to 1/0 copper conductors
Always follow local code requirernents for conductor sizing.
Attitude
To 2000 meters (6,560 feet)
INTER ET CONNECTION OPTIONS
- ---- ------ - - - - --------- -- ------
Integrated Wj-Fj
.........
802,11b/g/n
Ethernet
Optional, 802,3, Cat5E (or Cat 6) UTP Ethernet cable (not included)
Cellular
optional, CELLMODEM-01 (3G) or CELLMODEM-03 (4G) or CELLMODEM-Ml (4G based LTE-M)
(not included)
COMPLIANCE
Compliance, IQ Envoy UL 60601-1/CANCSA 22,2 No, 61010-1
* Consumption monitoring is required for Enphase Storage Systems.
To learn more about Enphase offerings, visit enphase.com
i.aks docum I
i�r`� tENPHASE
2 0 0 r�
CrossRail System
Reviewed for Code Compliance
Kevin Powell
BU1814, PX2841, BN4866, RPX329
"Inspect -ion Solutions, LLC hereby certifies
That these plans are in compliance
With applicable codes, and have not
Been changed, altered, or modified
o, High quality, Gerl-nan-engineeted systen, for residential and comr-nemial installations By Inspections Solutions, LLC"
P Ll rail sizes available to SUrt Pit structural conditions
o, Universal components for @11 rail types
P Use 2 innovative components to turn this systern into Shared Rail or Tilt Up
P MK3 technology provides highest rail engagement
o Roof attachments for all roof types
s 100% code coi"i"ipliartt, structural validation for all solar states
o Fast installation with minimnal comiponent count tesult in low trital installed cost
Components
llmmff�
P.'I D—cllptla"
4000019 rrGWRlnl44-X, 166-, mill
4000020 CrassRail 44-)t 166", Dark
14000021 CossR.if 180", Mill
4000022 CrossRail 44-X, 180", Dark
PvO N b,,
4000508 CrossRail 80, 168'; Mill
11- Oil
Yeti Clamp
41000050-H Yeti Hidden EC for CR, Mill. 13mm Hex
L-Foot Er T-FOGt
P�"L' N—W D—np"-
4000630 L-Foot Slotted Set Mill
4900831 L-Foot Slotted Set, Dark
4000080 T-Foot X, Set Mill
r
CrossR20 148-X
P�,, t N—be^
D—l"'p-
4000662
CrossRail 48-K 166" Mill
4060663
CorisRaji 46-X, 166", Dark
14000675
CrossRail 148-X, 180, Mill
4000665
CrossRail qB-X, 180'. Dark
CrossRail Mid Clamp
4000601-H CR MC Silver, 30-47mm, 13mm Hex
4000602-H CR MC Dart, 30-47mm, 13mm Hex
Q009688-H SR MC Silver, 30-50mm, 13mm Hex
4000689-H SR MC Silver, 30-50mm, 13mm Hex
1W -111
Aluminum
End C12MP
rafl
4005344
CrossRaff EC Silver, AL 32-33mm
4005169
CrossRail EC Silver, AL 34-36mm
4005290
CrossRail EC Silver, AL 37-38mm
4005170
CrossRail EC Silver, AL 39AIrnm
4005291
CrossRail EC Silver, AL 42-144mm
4005171
CrossRail EC Silver, AL q 5-147mm
4005292
CrossRail EC Silver, AL 48mm
4005172
CrossRail EC Silver, AL 4S-50nnn
DWI
T
Tile Hooks
P ;, t N um r,, Oe,,mp,mn
4000034 Flat Tile Hook
4001294 Tile Hook 3S
4000521 Singleftok
91
CrossRail LIS-XL
4000695 CrossRaff 4841- 166, Mill
4000705 CrossRail 48-XL, 166, Dark
CrossRail End Clamp
4DD0429 CR EC Silver 30-50mm, SR 30-45mm
4000430 CR EC Dark 30-SOmm, SR 30-45mm
4000003 SR EC Silver 46-50mm
4000004 SR EC Dark 46-50mm
CrossRail
Rail Connector
4000051
Rail Connector CR /44-X, Set, Mill
4000952
Rail Connector CR 444, Set Dark
4000385
R.ilCn. CR48-X,48-XL Struct Set, Mill
4000386
R.i]Conn CR48-X,49-XL SMct Set, Dark
4001196
Rail Connector UL 2703 Set, CROO, Mill
Standing Seam PowerClamps
P.,t Nt—h-
4000016 Standing Seam Pa"rClarrlp, Mini
4000017 Standing Seam PowerClamp, Standard
We support PV systems
Formerly Everest Solar Systems A -
Rail Shelf
Allows for easier rail support
Migns CrossRail T- Bolt channel
K2 EverSeal
s Pre Installed butyl flexible flashing
w 20- years of proven, water searing technology
� TAS 1001LA) arid Wind Driven Rain tested and approved
Splice Foot X & X
Patent Pending I
Self -Tapping Screws
Self-sealing, no sealant re*rcd
Self -tapping; no pilot holes required
2 screws included per mount
Splice Foot X & X!.
Patent Pending
P.,t N—b"
4000113 Splice Foot X Yjtmill
4000162 Splice Foot XL Kit, Mill
All- in -one mount and splice foot
K2 EverSeal technology
20-, yearr, of proven water sealing technology on asphalt
Self drilling lag screws -- less tools needed
OptiInized for CrossRail systems and corriponents
No L Poot needed
i, T- Bol' hardware Included