HomeMy WebLinkAbout23-67795335 Eighth Street Zephyrhills, FIL 33542 *,hone: (813) 780-0020 Fax: (813) 780-0021 CONSTRUCT SINGLE FAMILY 2580 SQ FT Mechanical Permit Fee $166.67 Driveway Fee $45.00 Park Impact Fee - Single Family/Townhome $769.56 Address Fee $30.00 SIF 1 percent Fee $83.28 Transportation Impact Fee $3,595.68 Plumbing Permit Fee $220.96 Admin Fee / (Provider Service) $180.00 Public Safety Impact Fee -Admin $26.35 Electrical Permit Fee $311.44 Irrigation 3/4 Meter (Cale) $794.92 3/4 Water Meter Fee (Cale) $794.92 Transportation Impact Fee - City $36.32 Building Permit Fee $1,849.60 Sewer Connection Residential Fee $2,400.00 Water Connection Residential Fee $1,140.00 School Impact Fee - Single Family $8,328,00 Public Safety Impact Fee -Police $254.00 REIRSPECTILT111 FEES: (c)11ith respect to Reinspection fees will comply with Florida Statute 553.80(2)(c) the local government shall impose a fee of four times the amount of the fee imposed for the initial inspection or first reinspection, whichever is greater, for each subsequent reinspection. Notice: In addition to the requirements of this permit, there may be additional restrictions applicable to this property that may be found in the public records of this county, and there may be additional permit required from other governmental entities such as water management, state agencies or federal agencies. improvements to your property. If you intend to obtain financing, consult with your lender or an attorncm accordance with City Codes and Ordinances. NO OCCUPANCY BEFORE C.O. NO OCCUPANCY BEFORE C.O. ll CONTRACTO,SIGNATURE PE IT OFFICE* V PERMIT EXPIRES IN 6 MONTHS WITHOUT APPROVED INSPECTION CALL FOR INSPECTION - 8 HOUR NOTICE REQUIRED PROTECT CARD FROM WEATHER 813-780-0020 City of Zephyrhills Permit Application Fax-813-780-0021 Building Department Owner's Address 23975 Park Sorrento, Ste. 220, Calabasas, CA 91302 Owner Phone Number �— Fee Simple Titleholder Name I N/A Owner Phone Number Fee Simple Titleholder Address N/A JOB ADDRESS 6656 Back Forty Loop LOT # 2602 SUBDIVISION Abbott Square PARCEL ID# 04-26-21-0160-02600-0020 (OBTAINED FROM PROPERTY TAX NOTICE) WORK PROPOSED II./ II NEW CONSTR 8 ADD/ALT SIGN DEMOLISH INSTALL REPAIR PROPOSED USE u V u SFR Q COMM 0 OTHER TYPE OF CONSTRUCTION 10 BLOCK FRAME STEEL O DESCRIPTION OF WORK Single Family Residence / Pool / Screen Enclosure / Fence BUILDING SIZE U/R SF 3016 SQ FOOTAGE 2580 HEIGHT 28' Y(iBUILDING $ 361920 VALUATION OF TOTAL CONSTRUCTION t �� t� C , `�` 1 (�/r ELECTRICAL $ 54288 � • AMP SERVICE Vi PLUMBING $ 36192 PROGRES W.R.E.C. jMECHANICAL $ 25334.4 VALUATION OF MECHANICAL INSTALLATION � _�l eel =GAS ® ROOFING SPECIALTY OTHER { FINISHED FLOOR ELEVATIONS FLOOD ZONE AREA DYES I o . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .. . II...__. _7.._. .- . . BUILDER COMPANY I Lermar Homes, LLC SIGNATURE REGISTERED Y / N FEE CURREN Address 4301 W oy Scout Blvd Suite 600 Tampa, FL 33607 License # CGC1518166 �� ELECTRICIAN COMPANY Edmonson Electric, Inc. SIGNATURE REGISTERED Y / N J FEE CURREN Address F License # EC13005408 PLUMBER COMPANY Bayonet Plumbing, Heating & AC, Inc SIGNATURE REGISTERED Y / N FEE CURREN Y / N Address License # I CFC042998 MECHANICAL COMPANY Bayonet Plumbing, Heating & AC, Inc SIGNATURE REGISTERED Y / N FEE CURREN Y / N Address License # �CAC058062 OTHER COMPANY C Sterling Quality Roofing, Inc {,3 SIGNATURE REGISTERED Y / N FEE CURREN Address License # �CCC057991 1111111111111/1/11//1111111111//1111111/1111/I11////11111111111811/ RESIDENTIAL Attach (2) Plot Plans; (2) sets of Building Plans; (1) set of Energy Forms; R-O-W Permit for new construction, Minimum ten (10) working days after submittal date. Required onsite, Construction Plans, Stormwater Plans w/ Silt Fence installed, Sanitary Facilities & 1 dumpster; Site Work Permit for subdivisions/large projects COMMERCIAL Attach (2) complete sets of Building Plans plus a Life Safety Page; (1) set of Energy Forms. R-O-W Permit for new construction. Minimum ten (10) working days after submittal date. Required onsite, Construction Plans, Stormwater Plans w/ Silt Fence installed, Sanitary Facilities & 1 dumpster. Site Work Permit for all new projects. All commercial requirements must meet compliance SIGN PERMIT Attach (2) sets of Engineered Plans. ****PROPERTY SURVEY required for all NEW construction. Directions: Fill out application completely. Owner & Contractor sign back of application, notarized If over $2500, a Notice of Commencement is required. (A/C upgrades over $7500) ** Agent (for the contractor) or Power of Attorney (for the owner) would be someone with notarized letter from owner authorizing same OVER THE COUNTER PERMITTING (copy of contract required) Reroofs if shingles Sewers Service Upgrades A/C Fences (Plot/Survey/Footage) Driveways -Not over Counter if on public roadways..needs ROW NOTICE OF DEED RESTRICTIONS: The undersigned understands that this permit may besubject to "deed" restrictions" which may bemore restrictive than County regulations. The undersigned assumes responsibility for compliance with any applicable deed restrictions. UNLICENSED CONTRACTORS AND CONTRACTOR RESPONSIBILITIES: If the owner has hired a contractor or contractors to undertake wmrk, they may be required to be licensed in accordance with otuhn and local regulations. If the contractor is not licensed an required by law, both the owner and contractor may be cited fora misdemeanor violation under state \ovv. If the owner or intended contractor are uncertain as to what licensing requirements may apply for the intended work, they are advised to contact the Pasco County Building Inspection Division —Licensing Section at 727-847- 8009. Fudhermone, if the owner has hired a contractor orcontractors, he is advised to have the contractor(s) sign portions of the "contractor Block" of this application for which they will be responsible. If you, an the owner sign as the oontracJor, that may bean indication that he is not properly licensed and is not entitled to permitting privileges in Pasco County. TRANSPORTAT|ON|k0PAClJUT|L|T|ES IMPACT AND RESOURCE RECOVERY FEES: The undersigned understands that Transportation Impact Fees and Recourse Recovery Fees may apply to the construction of new bui|dingo, change of use in existing bui|dingn, or expansion of existing bui|dingo, as specified in Pasco County Ordinance number8Q-07 and 9O-U7.auamended. The undersigned also understands, that such fees, as may be due, will be identified at the time of permitting. It is further understood that Transportation Impact Fees and Resource Recovery Fees must be paid prior to receiving e ^oartifioa0a of occupancy" or final power release. If the project does not involve o uohifiomh* of occupancy or final power release, the fees must be paid prior to permit issuance. Furthermore, if Pasco Cuunh/VVahar/Sewor Impact fees are due, they must be paid prior to permit issuance in accordance with applicable Pasco County ordinances. CONSTRUCTION LIEN LAW (Chapter 713.Florida Statutes, asmmnmnded): |fvaluation nfwork io$2.5U0.00urmore, | certify that |. the appUuant, have been provided with a copy of the "Florida Construction Lien Law —Homeowner's Protection Guide" prepared by the Florida Department of Agriculture and Consumer Affairs. If the applicant is someone other than the "owner", I certify that I have obtained a copy of the above described document and promise in good faith to deliver ittothe ^ownor"prior Vncommencement. CONTRACTOR"S/OVVNER'SAFF|DAV|T: I certify that all the information in this application is accurate and that all work will be done in compliance with all applicable |ewa regulating oonxtrun1inn, zoning and land development. Application is hereby mode to obtain a permit to do work and installation an indicated. | certify that no work or installation has commenced prior to issuance of permit and that all work will be performed to meet standards of all laws regulating oonotnuotinn. County and Qh/ uodoa, zoning regulations, and land development regulations in the jurisdiction. | also certify that I understand that the regulations of other government agencies may apply to the intended work, and that it is myresponsibility toidentify what actions | must take hubaincompliance. Such agencies include but are not limited to: - Department ofEnvironmental PnubaoUon-Cyp,ouo Bayheado, Welland Areas and Environmentally Sensitive Lands, Water/Wastewater Treatment. - Southwest Florida VVahor Management OiotricL-WeUe, Cypress Boyheedo, Wetland Aroao, Altering VVabaroournoo. - Army Corps ofEnginoene-SeowaUo.Docks, Navigable Waterways. - Department of Health & Rehabilitative Services/Environmental Health Unit-VVe||o, Wastewater Treatment, Septic Tanks. - USEnvironmental Protection Agency -Asbestos abatement. - Federal Aviation Authohh/-Runvvaya. | understand that the following restrictions apply Vothe use offill: - Use offill ionot allowed inFlood Zone ^\y'unless expressly permitted. - If the fi|| makahal is to be used in Flood Zone ^A^, it is understood that e drainage plan addressing u "compensating volume" will be submitted at time ofpermitting which is prepared by professional engineer licensed bythe State nfFlorida. - If the 0| muhmha| is to be used in Flood Zone ''A^ in connection with a permitted building using stem wall construction, | certify that fill will boused only tnfill the area within the stem wall. - If fill material is to be used in any area, | certify that use of such fill will not adversely affect adjacent properties. If use of fill in found to adversely affect adjacent properties, the owner may be cited for violating the conditions of the building permit issued under the attached permit application, for lots |eoo than one (1) acre which are elevated byfill, onengineered drainage plan iorequired. If | am the AGENT FOR THE OWNER, | promise in good faith to inform the owner ofthe permitting conditions set forth in this affidavit prior to commencing construction. | understand that a separate permit may be required for electrical work, p|umb|ng, oignu, wmUn, pools, air conditioning, gao, orother installations not specifically included in the application. A permit issued shall be construed to be a license to proceed with the work and not as authority to violate, cancel, alter, or set aside any provisions of the technical codes, nor shall issuance of a permit prevent the Building Official from thereafter requiring a correction of errors in plans, construction or violations of any codes. Every permit issued shall become invalid unless the work authorized by such permit is commenced within six months of permit isouanoe, or if work authorized by the permit is suspended or abandoned for a period of six (6) months after the time the work is commenced. An extension may be vaquoohed, in writing, from the Building Official fora period not to exceed ninety (AU)days and will demonstrate justifiable cause for the extension. If work ceases for ninety (90) consecutive days, the job is considered abandoned. OWNER OR Subscribed and sworn to- (or affirmed) before me this 4/512023 by _ Christopher Smith i���nally known to me or hasihave PFQdWG84 as identification. —Notary Public Commission qi��G2i�96057 Stephanie Farmer Name of Notary typed, printed or stamped TM; 8mdwr.T,*yFakuaaw,1*14i9 4,9 Subscribed and sworn to (or affirmed) Name of Notary typed, printed or stamped 9 ' Permit No. C 7� DatePermitted BuilderName/Owner n Control # County Parcel No. 0 // t 0 0 � SubDiv: �% I� r, A&4-41)e— Address/Location G 7 om-ci Classification/Type of Use TRANSPORTATION IMPACT FEE Rate: Sq. Ft Unit: Exempt 0 Yes No plow Determined Impact Fee Amount—S Zone No. TAZ: ' HR'Oi, IMPACT FEE Account (056) Single-Famiiy Detached House Mobile Home Residential(058) Other •' Fee Exempt CDYes = No How Determined Amount $ (! Land Account Land Credit Land Total Recreation Account Recreation Credit Recreation Total Zone Total Amount $ Exempt =Yes = No Flow Determined Land Account Land Credit Land Total Facility Account Facility Credit Facility Total Exempt Yes No Flow Determined Total Amount RESOURCE FEE ERU Total Amount ,+ a PERFORMED UNTILTHE TOTAL AMOUNTS LISTED HAVE TIMA DIT1010S OF PIMWEVT RECEIPT1,, DATE DESCRIPTION: LOT 2, BLOCK 26, ABBOTT SQUARE PHASE 2, ACCORDING TO THE PLAT THEREOF, RECORDED IN PLAT BOOK 90, PAGES 28-33, OF THE PUBLIC RECORDS OF PASCO COUNTY, FLORIDA. ALL ELEVATIONS REFERENCED TO NORTH AMERICAN VERTICAL DATUM OF 1988 (NAVD 88) LOT 15 BLOCK 26 ail a. LOT 16 BLOCK 26 Lu A, 0 � — — — — — — — — — — LOT 17 �I -/-9- BLOCK 26 16 SITE PLAN (NOT A SURVEY) Prepared for and Certified To: Lennar Homes SEC. 4, TWP. 26 S, RNG 21 E. PASCO COUNTY, FLORIDA (ABBOTT SQUARE PHASE 2) LOT 3 BLOCK 26 U N 88*08'23"W (P) I 10,50- (p) flj 2 (P) Ln LM 373' 212' 52.0 PROPOSED 0 LOT 2 BLOCK 26 2 STORY RESIDENCE 0- LL 19X6.9 9 9 PLAN 2551 NJ Z' Q ELEV"B" U PATIO GARAGE ENTRY + 7 Ld 3' ONC b WLK A C 0 r 35X15' 57-8" 2qS, z 37' 473 25.8' CO X U • V in N 88'08'23" W (P) 110.50'(P) LOT BLOCK 26 Wt rn 1 QI z! PCP 6 NOTES: LOT GRADING TYPE = A PROPOSED ELEVATIONS AND GRADING PROPOSED PAD ELEVATION SHOWN HEREON ARE TAKEN FORM THE ENGINEERING PLANS OF FRONT SET BACK = 20' "ABBOTT SQUARE RESIDENTIAL", PREPARED SIDE SET BACK = 75 BY "WRA" PROVIDED BY CLIENT LOT = 4973 SO. FT. SIDE SET BACK (CORNER LOT) 10' LIVING AREA = 1110 SO. FT. REAR SETBACK = 15' ENTRY = 33 SO. FT. GARAGE = 403 SO. FT. PROPOSED: I 0.00'PUBLIC UTILITY EASEMENT COVERED LANAI = N/A SO. FT. MINIMUM FLOOR ELEVATIONS: PATIO = 18 SO. FT. POOL AREA = NA SO. FT. LIVING AREA: 95.97' LEGEND: CONC. DRIVE = 339 SO. FT. GARAGE AREA: PROPOSED DRAINAGE FLOW A/C & CONC PAD = 12 SO. FT. ---= ELEVATIONS REFERENCED TO SIDEWALK = 28 SO. FT. (00.00)PROPOSED GRADE NORTH AMERICAN VERTICAL SIDE YARD SWALE = N/A SO. FT. DATUM OF 1988 E-00.00 = EXISTING GRADE CONSERVATION AREA = N/A SQ. FT. LOT OCCUPIED = 39 % APPARENT FLOOD HAZARD ZONE: "X"COMMUNITY NO. 120235 AREA TO IRRIGATE = 61 % SURVEY ABBREVATIONS (MAP NUMBER 12101 C-0289-F) EFFECTIVE DATE: 09/26/2014 A) = ARC LENGTH A/C — AIR CONDITIONER (D) — DEED INV — INVERT PC — POINT OF CURVE (R) - RECORD D.E= DRAINAGE EASEMENT LB =LICENSED BUISNESS PCC = POINT OF COMPOUND CURVE RNG = RANGE LEGEND VINYL FENCE AF - ALUMINUM FENCE EL OR ELEV = ELEVATION L.E = LANDSCAPE EASEMENT PCP = PERMANENT CONTROL POINT RRS = RAIL ROAD SPIKE CONC 0 ------- 0— SEE = BASE FLOOD ELEVATION BM — BENCH MARK EOP = EDGE OF PAVEMENT LEE = LOWEST FLOOR ELEVATION P/E POOL EQUIPMENT R/W = RIGHT OF WAY WOOD FENCE C — CURVE ESM7 = EASEMENT LS = LICENSED SURVEYOR PIS PAGE SEC SECTION PI = POINT ASPHALT (C = CALCULATED F/C = FENCE CORNER (M) = MEASURED OF INTERSECTION SN&D = SET NAIL AND DISK j " _ CENTERLINE FCM = FOUND CONCRETE MES = MITERED END SECTION PK =PARKER KALON LB#8 183 CHAIN LINK FENCE CLF = CHAIN LINK FENCE MONUMENT NCF = NO CORNER FOUND -t = PROPERTY LINE SIR = SET 112- IRON ROD LB# 8 183 C MP — CORRUGATED METAL PIP f HP = FOUND IRON PIPE O/A = OVERALL POB = POINT OF BEGINNING TBM = TEMPORARY BENCH MARK = BRICK COL=COLUMN FIR = FOUND IRON ROD OHW = OVERHEAD WIRE(S) POC = POINT OF COMMENCTMENT TOB = TOP OF BANK CONC = CONCRETE FN&D = FOUND NAIL & DISK O.R. = OFFICIAL RECORDS POL = POINT ON LINE TWP = TOWNSHIP ALUMINUM FENCE C/S = CONCRETE SLAB FOP FOUND OPEN PIPE (P) = PLAT PRC = POINT OF REVERSE CURVE LLE = UTILITY EASEMENT = COVERED CST = CLEAR SIGHT TRIANGLE FPP = FOUND PINCHED PIPE PB = PLAT BOOK PRM = PERMANENT REFERENCE MONUMEN] VF = VINYL FENCE JOB 15908522602 — SURVEYOR'S NOTES: SURVEYOR'S CERTIFICATE 1.) Current title information on the subject property had not been This certifies that A %4*iJ e hereon described furnished to Initial Point Land Surveying, LLC. at the time of this property was n I�IWervision and SITE PLAN *S 1708 Water Oak Drive E N a Tarpon Springs, Florida PIN �PIN Phone: (727)-831-1990 RG I W RG I E E Date of Site Plan: 5-24-23 DWG:AS-PH2-L2-BL26-SITE: meets the practice for FloridaPLS7123@gmail.co �Pls �Pls, 2.) This sketch was prepared without the benefit of a title search. surveys 4! d.of Lanq No instruments of record reflecting ownership, easements or LB# 8183 RGIW, RGIEo n r ;;J gned .IS File: rights -of -way were furnished to the undersigned, unless otherwise F Ad I I" tive shown hereon. pursught to Section 47 rtley Drawn by: DJB 3.) Roads, walks, and other similar items shown hereon were taker JtaJu .0 -V from engineering plans and are subject to survey. ate: (V P6.0 4.) This SITE PLAN does not reflect nor determine ownership. ey. TE W:34- 400 MOR ff up Checked byJH REVISIONS 5.) This SITE PLAN is subject to matters shown on the Plat of ORIDA "ABBOTT SQUARE PHASE 2" Ar 6.) Dimensions shown hereon are in feet and decimal portions Jeff M. H AND FLORIDA P thereof. V C1114 7.) Contractor and owner are to verify all setbacks, building MAPPER NO. dimensions, and layout shown hereon prior to any construction, NOT VALID WITHOUT THE ORIGINAL and immediately advise Initial Point Land Surveying, LLC. of any SIGNATURE AND SEAL OF A FLORIDA deviation from information shown hereon. Failure to do so will be LICENSED SURVEYOR AND MAPPER Initial Point Land Surveying, LLC. at user's sole risk. DESCRIPTION. LOT 2, BLOCK 26, ABBOTT SQUARE PHASE 2, ACCORDING TO THE PLAT THEREOF, RECORDED IN PLAT BOOK 90, PAGES 28-33, OF THE PUBLIC RECORDS OF PASCO COUNTY, FLORIDA. ALL ELEVATIONS REFERENCED TO NORTH AMERICAN VERTICAL DATUM OF 1988 (NAVD 88) SITE PLAN (NOT A SURVEY) Prepared for and Certified To: Lennar Homes SEC. 4, TWP. 26 S, RNG 21 E. PASCO COUNTY, FLORIDA (ABBOTT SQUARE PHASE 2) le LOT 15 1 LOT 3 < BLOCK 26 BLOCK 26 ' ---------- - 0 N 88-08-23- W (P) 110.50- (p) U sad2 (P) 37.3' 52.0' 0 Ul) .I, LOT 2 PROPOSED 0 BLOCK 26 2 STORY RESIDENCE LL BLOCK 26 q 9 PLAN 2551 LOT16 0 6 �u 3.0'X6.Cr 0 M ELEV"B" M PATIO UJ LL GARAGE R ENTRY 4.7- 3' ONC 0 0 3.5'X3.5' 52-8" 6 WALK 7.3 2,45 COEy Ln z 473' 25.8' V -------- -- LOT 17 '45 BLOCK 26 N88*08'23"W(P) 110,50'(P) LOT BLOCK 26 UJ hl MI z PCP NOTES: LOT GRADING TYPE = A PROPOSED ELEVATIONS AND GRADING PROPOSED PAD ELEVATION SHOWN HEREON ARE TAKEN FORM THE ENGINEERING PLANS OF FRONT SET BACK = 20' "ABBOTT SQUARE RESIDENTIAL", PREPARED SIDE SET BACK = 75 BY "WRA" PROVIDED BY CLIENT SIDE SET BACK (CORNER LOT) 10' LOT = 4973 SO. FT. LIVING AREA = 1110 SO. FT. REAR SETBACK= 15' ENTRY = 33 SO. FT. GARAGE = 403 SQ. FT. PROPOSED: 10.00'PUBLIC UTILITY EASEMENT COVERED LANAI = N/A SO. FT, MINIMUM FLOOR ELEVATIONS: PATIO = 18 SO. FT. POOL AREA = NA SO. FT. LIVING AREA: 95.97' LEGEND: CONIC. DRIVE = 339 SO. FT. GARAGE AREA: PROPOSED DRAINAGE FLOW A/C & CONIC PAD = 12 SO. FT. ELEVATIONS REFERENCED TO SIDEWALK = 28 SO. FT. NORTH AMERICAN VERTICAL (00.00) = PROPOSED GRADE SIDE YARD SWALE = N/A SO. FT. DATUM OF 1988 E-00.00 = EXISTING GRADE CONSERVATION AREA =—NZA SO. FT. LOT OCCUPIED = 39 % APPARENT FLOOD HAZARD ZONE:"X" COMMUNITY NO. 120235 AREA TO IRRIGATE = 61 % SURVEY ABBREVATIONS (MAP NUMBER 12101 C-0289-F) EFFECTIVE DATE: 09/26/2014 A) = ARC LENGTH (D) = DEED INV = INVERT PC = POINT OF CURVE (R) = RECORD LEGEND A/C = AIR CONDITIONER D.E= DRAINAGE EASEMENT LB =LICENSED BUISNESS PCC = POINT OF COMPOUND CURVE RNG = RANGE VINYL FENCE A BFE - BASE FLOOD ELEVATION RRS = RAIL ROAD SPIKE CONC F = ALUMINUM FENCE EL OR ELEV = ELEVATION Ll LANDSCAPE EASEMENT PCP = PERMANENT CONTROL POINT EOP = EDGE OF PAVEMENT LEE LOWEST FLOOR ELEVATION P/E POOL EOUIPMENT R/W - RIGHT OF WAY BM - BENCH MARK ESMT = EASEMENT LS = LICENSED SURVEYOR PG = PAGE SEC = SECTION WOOD FENCE C = CURVE F/C = FENCE CORNER (M)= MEASURED PI = POINT OF INTERSECTION = ASPHALT (C) = CALCULATED SN&D - SET NAIL AND DISK Ii = CENTERLINE FCM = FOUND CONCRETE MES = MITERED END SECTION PK =PARKER KALON LB#8183 CHAIN LINK FENCE CLF = CHAIN LINK FENCE MONUMENT NCF = NO CORNER FOUND It = PROPERTY LINE SIR = SET 112- IRON ROD LB# 8183 CMP = CORRUGATED METAL PIP HP = FOUND IRON PIPE O/A = OVERALL POB = POINT OF BEGINNING TBM = TEMPORARY BENCH MARK = BRICK COL -COLUMN FIR = FOUND IRON ROD OHW = OVERHEAD WIRE(S) POC = POINT OF COMMENCTMENT TOB = TOP OF BANK CONC = CONCRETE FN&D = FOUND NAIL & DISK O.R. = OFFICIAL RECORDS POL = POINT ON LINE TWP = TOWNSHIP ALUMINUM FENCE C/S = CONCRETE SLAB FOP FOUND OPEN PIPE (P) = PLAT PRC = POINT OF REVERSE CURVE UE:UTILITY EASEMENT = COVERED CST = CLEAR SIGHT TRIANGLE EPP FOUND PINCHED PIPE PB = PLAT BOOK FIRM = PERMANENT REFERENCE I I MONUMENJ VFVINYLFENCE JOB 15908522602 SURVEYOR'S NOTES: SURVEYOR'S CERTIFICATE 1708 Water Oak Drive $SEE 1.) Current title information on the subject property had not been This certifies that s A i�ervision ereon described Tarpon Springs, Florida N Date of Site Plan: 5-24-23 - �R IN MP N' furnished to Initial Point Land Surveying, LLC. at the time of this property was n and Phone: (727)-831-1990 RGIW RGIE DWG:AS-PH2-L2-BL26-SITE SITE PLAN meets the a0 Is actice for FloridaPLS7]23@gmail.co TWP 1 5, �p 1 5 2.) This sketch was prepared without the benefit of a title search. surveys, d.of Lanq LB# 8183 RG I W, RGIE No instruments of record reflecting ownership, easements or S g 1ned File: rights -of -way were furnished to the undersigned, unless otherwise Ad 1hi�q t 11 i Drawn by. DJB shown hereon, pursurght to Section 47 rtley 3.) Roads, walks, and other similar items shown hereon were taker, .0 ta (0 -0 ate: 112 .06.0 5 Checked by:JH from engineering plans and are subject to survey. 0 4.) This SITE PLAN does not reflect nor determine ownership. REVISIONS TE 08:34- 4`00' 5.) This SITE PLAN is subject to matters shown on the Plat of ca, "ABBOTT SQUARE PHASE 2" ORIDA 6.) Dimensions shown hereon are in feet and decimal portions Jeff M. H of FLORIDA P V AND there. 7.) Contractor and owner are to verify all setbacks, building MAPPER NO dimensions, and layout shown hereon prior to any construction, NOT VALID WITHOUT THE ORIGINAL and immediately advise Initial Point Land Surveying, LLC. of any SIGNATURE AND SEAL OF A FLORIDA deviation from information shown hereon. Failure to do so will be LICENSED SURVEYOR AND MAPPER Initial Point Land Surveying, LLC. at user's sole risk. Plan Model Elevation Garage Lot Size Block Lot V5 o? Setbacks:Front Rear Sides Roof Shingle Dime rah Notice to Building Official of Use of Private Provider Effective January 20, 2003 Project Name: 6656 Back Forty Loop Parcel Tax ID: 04-26-21-0160-02600-0020 Services to be provided: Plans Review— X Inspections Note: If the notice applies to either private plan review or private inspection services the Building Official may require, at his or her discretion, the private provider be used for both services pursuant to Section 553.791(2) Florida Statute. STEVE SMITH the fee owner, affirm I have entered into a contract with the Private Provider indicated below to conduct the services indicated above. Private Provider Firm: VIRTUAL REVIEW ASSIST, INC. Private Provider: DEBPA ANNE KLAHR Address: Telephone: MRONZ-11M Email Address (Optional): deb@virtualreviewassist.com Florida License, Registration or Certificate #: (LIC # BU1967/ PX2300/ BN4615) I have elected to use one or more private providers to provide building code plans review and/or inspection services on the building that is the subject of the enclosed permit application, as authorized by s. 553.791, Florida Statutes. I understand that the local building official may not review the plans submitted or perform the required building inspections to determine compliance with the applicable codes, except to the extent specified in said law. Instead, plans review and/or required building inspections will be performed by licensed or certified personnel identified in the application. The law requires minimum insurance requirements for such personnel, but I understand that I may require more insurance to protect my interests. By executing this form, I acknowledge that I have made inquiry regarding the competence of the licensed or certified personnel and the level of their insurance and am satisfied that my interests are adequately protected. I agree to indemnify, defend, and hold harmless the local government, the local building official, and their building code enforcement personnel from any and all claims arising from my use of these licensed or certified personnel to perform building code inspection services with respect to the building that is the subject of the enclosed permit application. I understand the Building Official retains authority to review plans, make required inspections, and enforce the applicable codes within his or her charge pursuant to the standards established by s. 553.791, Florida Statutes. If I make any changes to the listed private providers or the services to be provided by those private providers, I shall, within I business day after any change, update this notice to reflect such changes. The building plans review and/or inspection services provided by the private provider is limited to building code compliance and does not include review for fire code, land use-, environmental or other codes. The following attaPhrric-rits. are provided as required: 1. Qualification statements and/or resumes of the private provider and all duly authorized representatives. 2. Proof of insurance, for professional and comprehensive liabilityamo inthe, untof $1 million p tr o ccurre-rice relating to all services p.(-'rf-bimed as a private provider, including tail coverage for a minimum of 5 years subsequent to the performance of building code, inspection services.. Individual Corporation Partnership LENNAR HOMES. LLQ Print Corporation Name PrilltPartnership Name By: By-, -(signature) (signature) (signature) Print print print Name: Name,: Christopher Smith Name: AddTess: its: Authorized Agent its Address: 700 NW I 01th -Ave Address; Telephone Miami, FL 33172 Telephone- Telephone No, 813-574-5700 No.: I'lleaseuse appropriate notary block. STATE OF FLORIDA Individual Bcforeme, this day of 20—peirsonally SN"r5d who * executed the foregoing in ' struan'tilt, and acknowledged before me that same was executed for the purposes therein Corp oration Bef,rem,,this 22ND day of MAY, 20Z3 personally appeared Of Lennar Homes, LLC Corporation, oil -behalf of th6state corpoTation, who executed the f6regoing instrument and acloiovledged before; me that same was executed for the purposes therein expressed. personally known X r- Produced identification Type of identification produced I A Partnership Before me, this _ day of 20— personally appeared partner/agmtonbehalf of a partnership, who executed the foregoing instrument And acknowledged before me that saint, was rzyeouteffor the purposes I thereim expressed. ASHLEE CALLAHAN NotaTyPublic Stamp-, Ca Air My COMMISSION # HH 299980 Commission Expires: EXPIRES. Noveinber 30 2026 Page 2 of 2 VIRTUAL REVIEW ASSIST Private Provider .......... Private Provider Firm: Virtual Review Assist, Inc. Private Provider: Debra Anne Klahr, BU 1967 Address: 747 Southwest 2,d Avenue Gainesville, Fl, 32601 Phone: 813-391-2959 Email: lucy a - Oyirtualreviewassist.com Project: New SFR Address(s): 6656 BACK FORTY LP I hereby certify that to the best of my knowledge and belief the plans submitted were reviewed for and are in compliance with the Florida Building Code and all local amendments to the Florida Building Code by the following affiant, who is duly authorized to perform plans review pursuant to Section 553.791, Florida Statute and holds the appropriate license or certificate: Name: Debra Anne Klahr Plan Sheets CS,A1,A2,A3,A4, A5,A6.2,A6.1,SNO,SN1,S3,S4,S5,S6,SS,ST,SI I'SI2,WPI, WP2,'WP2.1,PA1.0,PAl.1, PAI.2,PAI.3,PAI.4, PAI.5,SHI.0,SHI.1,SHI.2,SHI.3,SHI.4,SHI.5 Florida License/Registration/Certification #(s) and description: FS468 Certified Standard Plans Examiner License #: PX2300 if Signature of Reviewer: SWORN AND SUBSCRIBED bef6re me by Debra Anne Klahr being personally known to meV4 ", or having produced as identification and who being fully sworn and cautioned, state that the for g is true correct to the best of his/her knowledge or belief. Ashlee Callahan tignatike' of Notary Print Name Notary Public: NOTARY STAMP BELOW My commission expires: ASHLUE CALLAHAN MY COMMISSION P, HH 295980 kv EXPIRE& Novelrber 310, 2026 No-wal 01 QUAN N1 W-11 M a IN 13 1002 W N [A] I IN 11-11 FAW11 Is 131 ON FIRE MARSHAL #01 - Required Permits DATE: 7/22/2023 EXAMINER: Debra Klahr PX2304. IV Building ❑ PMLection Only r-7 V, Plumbing F—I LUS ection OnL Mechanical 0 Inspection Only Electrical Amp F-1 tns pection Only Roof Ll Gas M Medical Gas E] Fire Sprinklers ❑ On Site Piping E] Fire Line El Irrigation El Fire Alarm El Potable Backflow Assembly F-1 Fire Line Backilow Preventer El Irrigation Backilow Assembly E] Demolition El Walk-in Cooler 0 Refrigeration El Hood r-1 Ansul El Fence/Wall ❑ Grease Trap El Other F-1 Other Buildine Data Type Construction: I Risk Category: Occupancy Load ancy Classification: .Factory 0 11 Residential Assembly E-:= FD'ay Care/Educational Hazardous nal El,,Mercantilc S torage ❑;Utility — Building Use: SINGLE FAMILY RESIDENCE Alteration 1 Level I [E—JLevel 2 E—J,Level 3 F ,Rf New Construction E] Interior Finish ❑ Interior Remodel ❑ Exterior Remodel ❑ Addition Ej Revision Overall Size: 30 X 53-4 Number of Stories: 2 Total Sq. Ft.: 3016 Living Area: 2580 Covered Area: 436 # of Bedrooms: 6 # of Baths: 3 Cost per square foot: Estimated Value: Roof DTile F1 Built --up El Metal F-1 Other Squares: 20 Zoning: Wi orne Debris: 011risideOutside Energy Code: 405-2022 SUP Flood Zone: X Base Flood Elevation: Finish Floor Elevation: Hydrostatic Vents? 10"I""Yes V1111 No Sq- Ft. Enclosed Space Below BFE: # of Vents: Size of Vents: I Total Sq. In. Permanent Openings MX Central A/C 0 Gas A/C 9 Heat Pump E] Window A/C E] Gas Heat El Electric Heat IJTW�— I = Sanitary Sewer Storm Sewer Catch Basins Potable Water Underground Fire Line Front Rear Left Right As per Approved Site Plan Comments: