Loading...
HomeMy WebLinkAbout23-6824City of Zephyrhilis 117 5335 Eighth Street Zephyrhills, FL 33542 ELCMISC-006824-2023 Phone: (813) 780-0020 Fax: (813) 780-0021 Issue Date: 08/25/2023 •i 1111111 ! 11� Address: 7097 Steer Blade Dr ZEPHYRHILLS, FL 33541 Building Valuation: $0.00 Electrical Valuation: $39,220.00 Mechanical Valuation: Plumbing Valuation: Total Valuation: $39,220.00 Total Fees: $236.10 Amount Paid: $236.10 Date Paid: 8/25/2023 10:15:43AM REINSPECTION FEES: (c) With respect to Reinspection fees will comply with Florida Statute 553.80(2)(c) the local government shall impose a fee of four times the amount of the fee imposed for the initial inspection or first reinspection, whichever is greater, for each subsequent reinspection. Notice: In addition to the requirements of this permit, there may be additional restrictions applicable to this property that may be found in the public records of this county, and there may be additional permit required from other governmental entities such as water management, state agencies or federal agencies. accordance with City Codes and Ordinances. NO OCCUPANCY BEFORE C.O. NO OCCUPANCY BEFORE C.O. CONTRACTOR SIGNATURE 0 NO PufpO T•I V I "MIX11111 II IL Iffillink-1 111141 ua 0 i 0 0 @ Fff WA T.Tjff-,T7J 9JFjV:j'A�8 813-780-0020 City of Zephyrhills Permit Application Fax-813-780-0021 Building Department Date Received Phone Contact for Permitting 321 247 -- 6073 €€*&11 fib €€ "'-a- . J. Owner's Name RAUL MOCETE Owner Phone Number (321) 247-6073 Owner's Address 7097 STEER BLADE DRIVE Owner Phone Number 321-247-6073 Fee Simple Titleholder Name Owner Phone Number 321-247-6073 Fee Simple Titleholder Address JOB ADDRESS 7097 STEER BLADE DRIVE, ZEPHYRHILLS, FL 33541 LOT # SUBDIVISION SILVERADO RANCH I PARCEL ID# 32-25-21-0040-01400-0060 (OBTAINED FROM PROPERTY TAX NOTICE) WORK PROPOSED NEW CCNSTR ADD/ALT SIGN DEMOLISH IZI INSTALL REPAIR 8 PROPOSED USE SFR COMM �- OTHER TYPE OF CONSTRUCTION BLOCK FRAME STEEL DESCRIPTION OF WORK Installation of Photovoltaic Solar Panels on Rooftop & Derate main breaker in metemain from 2fl0a-175 BUILDING SIZE � SQ FOOTAGE HEIGHT =BUILDING $ 38,320.00 VALUATION OF TOTAL CONSTRUCTION =ELECTRICAL S AMP SERVICE PROGRESS ENERGY W.R.E.C. 900.00� =PLUMBING $ =MECHANICAL VALUATION OF MECHANICAL INSTALLATION =GAS [_ ROOFING SPECIALTY = OTHER FINISHED FLOOR ELEVATIONS _ FLOOD ZONE AREA =YES NO BUILDER SIGNATURE Address ELECTRICIAN SIGNATURE Address PLUMBER SIGNATURE Address MECHANICAL SIGNATURE Address OTHER SIGNATURE Address "` j) .' )) j( ��If Cameron Chnsfensen s�..J�l. COMPANY REGISTERED 6210 Hoffner Ave Ste 100 Orlando FL 32822 Matthew Franz COMPANY REGISTERED 6210 Hoffner Ave Ste 100 Orlando FL 32822 COMPANY REGISTERED a COMPANY REGISTERED COMPANY REGISTERED Momentum Solar -'t "(N FEE CURREN N License # GVC57 )36 Momntum Solar Y / N FEE CURREN N License# I EC13008217 FEE CURREN Y / N License # Y / N PEE CURREN License # FEE C:JRREN Y / N License # � # � f ! t t f ! t i # t � 6 ! f # i � ! i II t � � • # • � ! E � E # ! € i t � # ! ! • � i f ! i ! i ! # $ ! R i � � � ! l i i ! i RESIDENTIAL Attach (2) Plot Plans; (2) sets of Building Plans, (1) set of Energy Forms; R-O-W Permit for new construction, Minimum ten (10) working days after submittal date. Required onsite, Construction Plans, Stormwater Plans w/ Silt Fence installed, Sanitary Facilities & 1 dumpster; Site Work Permit for subdivisions/large projects COMMERCIAL Attach (2) complete sets of Building Plans plus a Life Safety Page, (1) set of Energy Forms. R-O-W Permit for new construction. Minimum ten (10) working days after submittal date. Required onsite, Construction Plans, Stormwater Plans w/ Silt Fence Installed, Sanitary Facilities & 1 dumpster. Site Work Permit for all new projects. All commercial requirements must meet compliance SIGN PERMIT Attach (2) sets of Engineered Plans. ""PROPERTY SURVEY required for all NEW construction. Directions: Fill out application completely. Owner & Contractor sign back of application, notarized If over $2500, a Notice of Commencement is required. (A/C upgrades over $7500) " Agent (for the contractor) or Power of Attorney (for the owner) would be someone with notarized letter from owner authorizing same OVER THE COUNTER PERMITTING (copy of contract required) Reroofs if shingles Sewers Service Upgrades A/C Fences (Plot/Survey/Footage) Driveways -Not over Counter if on public roadways..needs ROW 813-780-0020 City of Zephyrhills Permit Application Fax-813-780-0021 Building Department NOTICE OF DEED RESTRICTIONS: The undersigned understands that this permit may be subject to "deed" restrictions' which may be more restrictive than County regulations. The undersigned assumes responsibility for compliance with any applicable deed restrictions. UNLICENSED CONTRACTORS AND CONTRACTOR RESPONSIBILITIES: If the owner has hired a contractor or contractors to undertake work, they may be required to be licensed in accordance with state and local regulations. If the contractor is not licensed as required by law, both the owner and contractor may be cited for a misdemeanor violation under state law. If the owner or intended contractor are uncertain as to what licensing requirements may apply for the intended work,. they are advised to contact the Pasco County Building Inspection Division —Licensing Section at 727-847- 8009, Furthermore, if the owner has hired a contractor or contractors, he is advised to have the contractor(s) sign portions of the "contractor Block" of this application for which they will be responsible. If you, as the owner sign as the contractor, that may be an indication that he is not properly licensed and is not entitled to permitting privileges in Pasco County. TRANSPORTATION IMPACTIUTILITIES IMPACT AND RESOURCE RECOVERY FEES: The undersigned understands that Transportation Impact Fees and Recourse Recovery Fees may apply to the construction of new buildings, change of use in existing buildings, or expansion of existing buildings, as specified in Pasco County Ordinance number 89-07 and 90-07, as amended. The undersigned also understands, that such fees, as may be due, will be identified at the time of permitting. It is further understood that Transportation Impact Fees and Resource Recovery Fees must be paid prior to receiving a "certificate of occupancy' or final power release. If the project does not involve a certificate of occupancy or final power release, the fees must be paid prior to permit issuance. Furthermore, if Pasco County Water/Sewer Impact fees are due, they must be paid prior to permit issuance in accordance with applicable Pasco County ordinances. CONSTRUCTION LIEN LAW (Chapter 713, Florida Statutes, as amended): If valuation of work is $2,500.00 or more, I certify that I, the applicant.. have been provided with a copy of the "Florida Construction Lien Law —Homeowner's Protection Guide" prepared by the Florida Department of Agriculture and Consumer Affairs. If the applicant is someone other than the "owner", I certify that I have obtained a copy of the above described document and promise in good faith to deliver it to the "owner" prior to commencement. CONTRACTOR'S/OWNER'S AFFIDAVIT: I certify that all the information in this application is accurate and that all work will be done in compliance with all applicable laws regulating construction. zoning and land development. Application is hereby made to obtain a permit to do work and installation as indicated. I certify that no work or installation has commenced prior to issuance of a permit and that all work will be performed to meet standards of all laws regulating construction, County and City codes, zoning regulations, and land development regulations in the jurisdiction. I also certify that I understand that the regulations of other government agencies may apply to the intended work, and that it is my responsibility to identify what actions I must take to be in compliance. Such agencies include but are not limited to: Department of Environmental Protection -Cypress Bayheads, Wetland Areas and Environmentally Sensitive Lands, WaterfWastewater Treatment. Southwest Florida Water Management District -Wells, Cypress Bayheads, Wetland Areas, Altering Watercourses. Army Corps of Engineers -Seawalls, Docks, Navigable Waterways. Department of Health & Rehabilitative Services/Environmental Health Unit -Wells, Wastewater Treatment, Septic Tanks. US Environmental Protection Agency -Asbestos abatement. Federal Aviation Authority -Runways. I understand that the following restrictions apply to the use of fill: Use of fill is not allowed in Flood Zone 'W unless expressly permitted. If the fill material is to be used in Flood Zone "A", it is understood that a drainage plan addressing a "compensating volume" will be submitted at time of permitting which is prepared by a professional engineer licensed by the State of Florida. If the fill material is to be used in Flood Zone "A" in connection with a permitted building using stem wall construction, I certify that fill will be used only to fill the area within the stem wall. If fill material is to be used in any area, I certify that use of such fill will not adversely affect adjacent properties. If use of fill is found to adversely affect adjacent properties, the owner may be cited for violating the conditions of the building permit issued under the attached permit application, for lots less than one (1) acre which are elevated by fill, an engineered drainage plan is required. If I am the AGENT FOR THE OWNER, I promise in good faith to inform the owner of the permitting conditions set forth in this affidavit prior to commencing construction. I understand that a separate permit may be required for electrical work, plumbing, signs, wells, pools, air conditioning, gas., or other installations not specifically included In the application. A permit issued shall be construed to be a license to proceed with the work and not as authority to violate, cancel, alter. or set aside any provisions of the technical codes, nor shall issuance of a permit prevent the Building Official from thereafter requiring a correction of errors in plans, construction or violations of any codes. Every permit issued shall become invalid unless the work authorized by such permit is commenced within six months of permit issuance, or if work authorized by the permit is suspended or abandoned for a period of six (6) months after the time the work is commenced. An extension may be requested, in writing, from the Building Official for a period not to exceed ninety (90) days and will demonstrate justifiable cause for the extension. If work ceases for ninety (90) consecutive days, the job is considered abandoned. WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE �1F COMMENCEMENT. FLORIDA JURAT (F S 17.03) OWNER OR AGENT �_. CONTRACTOR t Subscribed and sworn to (or affirmed) before me this Subscribed and sworn for affirmed) before me this 8/22/23 by Raul Mocete 8/22/23 by C.—rnn rmri,tP spn Who is/are personally known to me or has/have produced Who islare personally known to me or has/have produced drivers license as identification. as Identification. I ` - NotaryPublic _ i R & Notary Public Commission No. HH351297 Commission No. HH351297 Lisa Ann Knote Lisa Ann Knote Name of Notary typed, printed or stamped Name of Notary typed, printed or stamped { Notarypublic State of Florid i Lisa Anin Knote .r�lilt Expires i /2027 r Lis Lisa4nn Knote y A' �1�3 �4, ST,Kr,E OF FLOrRIVA.COUNTY OF PASCO THIS |STDCERT/FYTHATTHEFOREQ0N'|SA TRUEANDOFTHEDO('UyNENT ONFILE 0ROFPUBL|CRECORD\QTH}SOFF |CE WIT S Y ANDANDOFF|C|AL THIS BY CLERK OF Parcel ID 32-25-21-0646-01400-0060 (Card: I of 1) Classification 00100-Single Family Mailing Address Property Value LORA VIVIANA & MOCETE RAUL RUBEN Just Value $428,577 7097 STEER BLADE DR Ag Land $0 ZEPHYRHILLS, FL 33541-9124 Land $55,738 Building $370,458 Physical Address Extra Features $2,381 7097 STEER BLADE DRIVE, ZEPHYRHILLS, FL 33541 LegA-1 Descrip on tL__ (First 200 characters) -School Non School m Assessed $428,577 $428,577 SILVERADO RANCH SUBDIVISION PHASE 10A PB Homestead Exemption -$50,000 -$25,000 80 PG 107 BLOCK 14 LOT 6 Additional Exemptions -$0 -$0 Jurisdiction QDLQF ZEP±jj9_H_LljLa Community Dev District Taxable Value $378,577 $403,577 Land Detail (Card: I of I Line Use Description Code Zoning Units Type Price Condition Value 1 0100R SFR LP1-1 OPUD 6000.000 SF $8.88 1.00 $53,280 2 010OR SFR LP1-2 OPUD 3321.000 SF $0.74 1.00 $2,458 Additional Land Information Acres Tax Area FEMA Code Subsidence Activity Neighborhood Code(s) 0.21 2QZH X None Reported 51V—R YjP_W_*k%tg,tI Building Information - Use 0100-Single Family Residential (Card: I of I Year Built 2021 Stories 1.0 Exterior Wall 1 Concrete Block Stucco Exterior Wall 2 Roof Structure Gable or Hip Roof Cover Asphalt or Composition Shingle Interior Wall 1 Drywall Interior Wall 2 Flooring 1 Ceramic Clay Tile Flooring 2 Carpet Fuel Electric Heat Forced Air - Ducted A/C Central Baths 3.5 Line Code Description Sq. Feet Value I FOP01 FINISHED OPEN PORCH 259 $7,664 2 BASOI LIVING AREA 2,828 $333,435 3 FGR01 FINISHED GARAGE 622 $29,358 Extra Features (Card: 1 of I Line Code Description Year Units Value I RDWSWC DRVWAY/SIDEWALK CONC 2021 1,077 $2,381 Sales H story Previous Owner: D R HORTON INC Month/Year Book/Page Type DOR Code Condition Amount 9/2021 IQ454 L9 64 -L_ Warranty Deed 21 V $350,300 1/2021 JQ25�_�41 Warranty Deed 95, V $356,700 9/2020 JQLU_L_Z997 Warranty Deed _Q� I $27,563,199 11/2016 9ANIMAA Mineral Rights or Royalty Transfer V $0 4/2016 9_1kA1_QM Mineral Rights or Royalty Transfer V $0 4/2016 2u&�_ Mineral Rights or Royalty Transfer V $0 9/2011 RkN_L11zk Warranty Deed _U V $0 5/2010 MLLI_912 Certificate of Title 12 V $0 7/2005 r '? �1 �9 Quit Claim Deed V $0 1/2005 j�.ZZ_�j 10_43 Quit Claim Deed V $0 1/2005 UU_'LLz5_z Warranty Deed V $0 �­&z,� 0 8W2023 102113 - 06N, (2) RESIDENTIAL SOLAR EQUIPMENT LEASE AGREEMENT Welcome to the bright future of energy" This Lease outlines your rights and responsibilities as well as those uf|6S Solar. Customer Information Dr Zephyrhilts, a3354z Transaction Dote:7/31/2023 Customer Account Number: zsp/-3onn ����� Solar Inquiries v`�� ��/�� 88.974.0114 uorSupport@|GS.com 6100 Emerald Parkway Dublin, DH 43016 ER NUL NRAE YOUR NEW SOLAR PANEL SYSTEM INCLUDES: 8 S Additional Monitoring $O Installation $D Additional Maintenance $O System & Damage Limited Warranty 25Years Additional Design, Permitting, Application $0 Lien onYour Property None Additional Solar System Insurance $O �� , ^� ���M1�M���~���|ons` DURING TERM: ^ Transfer this Lease to another property owner (3ectionl3(A)(i)) ~ Prepay your future Lease Payments oto discounted rote -- |G3 Solar will continue to perform all of the operating, maintenance, and monitoring (Section 13(A)(ii)) ° Purchase the System onyour5-yeurmnniversory oranytime thereafter (Section 12) AFTER TERM ENDS: ^ Purchase the System atthe greater ofthe minimum purchase price orFair Market Value (Section 12) ~ Renew this agreement (Section 14) RESIDENTIAL SOLAR EQUIPMENT LEASE AGREEMENT Terms & Conditions This Lease and any Exhibits, Addenda, and Amendments (collectively, this "Lease") is the agreement between you (the ^Customer" or''you''or^you�)and |G5So|a� LLC(^|GSSolar" ^|GS^ or "we" o"our") covein the lease of the solar panel system (the "System") that will be installed at the address listed on the first page of this Lease (the "Property"). All obligations under this Lease, unless otherwise specified, will begin on the Transaction Date listed on the first page of this Lease. GS Solar will| the for months), plus any renewal term (the "Term") beginning on the Ist of the month immediately following the date the System obtains permission to operate from your electric utility (the "Interconnection Date"), with each successive 12-month period of the Term being a "Contract Year." i During the Term, you will pay IGS Solar for the use of the System at the rate set forth in the table on the first page of this agreement. ii At the time you signthis Lease, you must provide IGS Solar with a method of payment, which may be either by credit card, debit card, or ACH. You can authorize us to use your method of payment to pay invoices on a recurring basis by completing our Payment Authorization Form. If you choose to schedule automatic payments to be deducted from your bank account or credit card, you have the responsibility to ensure that there are adequate funds or credit limit. In addition, IGS Solar may charge you a billing fee each month in the amount of $_I.so , which may be waived, if you are enrolled in automatic payments, in IGS Solar's sole discretion. Any billing fee, if charged, will appear on your monthly invoice. |G3Solar will send anelectronic invoice each month to the email address you provided for the Monthly Lease Payment. C. AUTOMATIC CHARGES; LATE PAYMENTS You will pay a returned -check fee, which will not exceed the maximum allowed by law, for any check or withdrawal that is returned orrefused byyour bank, and the lesser of(i)alate payment fee equal tol.5Y6per month on all past -due amounts, or(ii)the maximum percentage allowed bylaw. MENEEW not limited to sales tax, excise tax, property tax. and other charges. If taxes applicable to this Lease change, you will pay the updated charged amounts. If, at the end of the Term of this Lease, you choose to purchase the System, you will pay any applicable tax on the purchase price, A.IGS SOLAR OBLIGATIONS |GS Solar will perform the following obligations at its sole cost and expense: i |GS Solar will construct orcause the construction ofthe System. ii. IGC Solar will provide you with revenue -grade meter to accurately measure the amount of electricity the System generates. iii |GS Solar will insure the System against damage and loss unless the damage or loss is caused by your gross negligence, or you intentionally damage the System. ix|GS Solar will arrange for repair ofthe System. x |GSSolar will not putelien onyour Property. |GSSolar may file informational Uniform Commercial [ode forms or similar statements with the appropriate secretary ofstate and/or county recorder's office to give notice of|GSSo|ar'sownership nfthe System. B. VGS SOLAR'S LIMITS ON OBLIGATION TO DELIVER i |GS Solar is not a utility or public service company and does not assume any obligations of a utility or public service company to supply your energy requirements, Nothing in this Lease will be construed as a dedication of the System topublic use. The System will not provide power to the customer in the event that the Property is disconnected from the Utility power grid. iiDuring the Term, you may require more electricity than the System generates.You will be solely responsible for maintaining access to obtaining, and paying for that electricity from your utility. iii. |G5Solar will not pay for electrical panel upgrades or correction of structural integrity problems, |GS Solar is not responsible for upgrades to the Property before orafter installation ofthe System. C. CUSTOMER OBLIGATIONS i You will not allow shade to interfere with the System's performance, and you will keep shrubs, trees, and other foliage trimmed. ii You will not clean or make any modif|cations, impnzvements, evis|ons, or additions to the System. iiiYou will promptly notify kS5Solar ifyou suspect RESIDENTIAL SOLAR EQUIPMENT LEASE AGREEMENT RS.SL.CS 0722 FL Lease IN the System is damaged, appears unsafe, cvif any part — the System —stolen. ix You will sign and return all documents |EBSolar sends toyou for your signature within 7days of receipt. u |GS Solar may, at its uption, install and maintain a cellular based gateway or utilize your internetconnectinnto monitor your solar photovoltaic System, You agree to provide and maintain' at your cost, a broadband |nternet connection and/or an electrical connection for the Term of this Lease and expressly allow |G5 Solar to access and use said internet connection for the Term. |frequested by|GSSolar, you agree topermit|GSSo|aroritscontmotor(s) to install and maintain a cellular based gateway for communication purposes. oi.Ynu will obtain all applicable approvals and authorizations for the required by your homeowner's assodation, community organization, and any otherwith an interest inyour Property, d you willadvise |GS Solar of those requirements that will affect the 5yst*m, its installation, oroperation. viiYou will not use the System toheat eswimming pool orhot tub. viii You will provide copies of your utility bills as reasonablywe estand you authorizeus to obtain your electrical usage history from your utility. VVewill treat those bills and usage history as confidential. ix, You represent and warrant to |6S Solar that you are the owner ofthe Property and that you are at least lOyears ofage. D. REPAIRS OR IMPROVEMENTS You must notify |GS Solar 30 days before making repairs or improvements toyour Property that could interfere with the System. You will not materially alter the location where the System is installed. You will continue to pay all Lease Payments during any downtime. E. ACCESS TO THE SYSTEM i You grant to |GSSolar and its contractors the right to access all of the Property as reasonably necessary for: l. Installing, operating, maintaining, repairing, removing, and replacing the System and making any additions to the System and installing complementary technologies on or about the location of the System; 2.Using and maintaining electric Unes, invedeo, and meters necessary to interconnect the System toyour Property's e|ectricxystemandto the utility's electric distribution system; and S.Takingany other action reasonably necessary in connection with insta||ing, opeeting, maintaining, repairing, removing, and replacing the System, and enforcing any remedies of |G5Solar under this Lease. ii. Our right to access will continue for 90 days after the Term expires to provide IGS Solar with time to remove the atthe end ofthe Lease if|GS Solar chooses todoso. |G3Solar will have access rights aLall times and you will not interfere with or permit any third party to interfere with such rights or access. |ii |G5 Solar will attempt to provide you with reasonable notice of our need to access the You will indemnify, defend, and hold hann|esx(GS Solar, its employees, officeo, directors, agents, financing parbners, successon, and asuigns, from all daims, actions, and demands, and all related costs' expenses' damages liabilities, penalties, |ossex, obligations, and liens of every kind arising out of o, resulting from your gross negligence or willful misconduct; provided that nothing will require you to indemnify IGS Solar against its own negligence or willful misconduct. The provisions of this Section 4(F) will survive the termination or expiration of this Lease. G. CUSTOMER WAIVERS Your obligation (opay Lease Payments and all other amounts you owe under this Lease will beabsolute and will not be subject toany abatement, defense, counterc|aim, setoff, recoupment, or reduction for any meson whatsoever. All amounts owed by you under this Lease will be payable in all events, including by your heirs and estate. You waive all rights you may have to revoke acceptance of the System nrtogrant asecurity interest in the System, and except asset forth in the following parts ofthis Lease, you waive all rights to cancel this Leese: Section 26 of this Lease' the Notice of Right toCancel onthe Signature Page, and Exhibit 1tothis Lease. A. THE FOLLOWING ITEMS MUST BE COMPLETE PRIOR TO INSTALLATION i |GSSolar will complete anengineering site audit, the final System design and real estate due diligence toconfirm the suitability ufthe Property, including any required changes orimprovements that must bedone by you, for the construction, installation, and operation ofthe System; ii |GS Solar will obtain all necessary governmental zoning' land use, and building permits (this does not include approvals or authorizations mentioned inSection S(#)(«)); iii |5S Solar will claim any ownership vebates, tax credits, renewable energy credits, and other environmental attdbutes, if any; iv. You will complete and return all documents related to the items mentioned in Section 5(A) (iii).asreasonably requested by|GS Solar. x If your Property is governed by homeowner's RESIDENTIAL SOLAR EQUIPMENT LEASE AGREEMENT 3 RS,SLCS, 0722 FL Lease association or similar community organization, you will collect all approvals and authorizations for the System. B. IGS SOLAR MAY TERMINATE THIS LEASE WITHOUT LIABILITY if, inits reasonable judgment, any ofthe conditions above are not satisfied, orfor any other reasons that are beyond |GSSo|ar'sreasonable control. Material changes to this Lease may only be made in a written amendment tothis Lease signed by you and |GS Solar. You authorize |GSSolar tomake corrections toany utility paperwork in order toconform tothis Lease, and any amendments or addenda. |GS Solar may assign' seU, or otherwise transfer the System and this Lease, nrany part, without your consent; however, your rights will not beaffected. The System is personal property comprised of removable equipment and will not be considered a fixture or in any way a part of your Property. IGS Solar owns the System, including all data generated from the System, for all purposes. You will keep the System free and clear of, and indemnify and defend IGS against, all claims, levies, liens, and other encumbrances on the System, except for any created by IGS Solar, You will own the electricity generated bythe System. Except for the electricity Solar will own everything produced by or otherwise related to the System, including but not limited to all tax credits, incentives, renewable energy credits, green tags, carbon offset credits, utility rebates, allowances, benefits, grants, and environmental attributes (collectively, "Benefits"), Throughout the Term, IGS Solar will have the exclusive right to use, trade, and/or sell all such Benefits. You will notenter into any agreementwith yourutility that would entitle your utility to claim any Benefits. Subject to applicable law, you will reasonably cooperate with IGS Solar so that IGS Solar may claim all Benefits, including entering into net metering agreements, interconnection agreements, and filing renewable energy/carbon offset credit registrations and/or applications for rebates from the federal, state, and/or local government, or a local utility, and giving those Benefits to IGS Solar. As long as you are not in default of this Lease you may purchasethe System, as is atany time onorafter the 5-year anniversary of the Interconnection Date. To purchase the System, you must deliver notice to IGS Solar of your intent to purchase and pay the greater of: A. THE MINIMUM PURCHASE PRICE The Minimum Purchase Price will be equal to the present value of the forecasted Lease Payments over the Term then remaining, discounted at a rate of5%; or B. THE FAIR MARKET VALUE FOR THE SYSTEM purchaseThe FMV will be calculated by an independent appraiser who is selected by agreement between you and IGS Solar. IGS will be responsible for the cost of the appraisal. If you h will transfer you any remaining manufacturers' warranties and will provide you with a bill of sale for the System. As of the date of the bill of sale, you will be responsible for all System maintenance, removal, repairs, monitoring, and all software required for the System, and the Limited Warranty attached as Exhibit 2 will be rendered null and A. IF YOU SELL YOUR PROPERTY, YOU MAY DO ANY ONE OF THE FOLLOWING i Transfer this Leese and the Lease Payments obligation tothe new owner |fiGDSolar consents tothe transfer; ii Prepay this Lease by paying |GSSolar the Lease Payments over the Term then remaining as described in SecUonl2(A). |G3 Solar will remain the owner ofthe 3ystem, and the new property owner will not owe any Lease Payments but must comply with all other provisions inthis Lease; o/ iii. If the sale occurs after the 5-year anniversary of the Interconnection Date' purchase the System for the amount as set forth in Section 12. 13YOU AGREE TO GIVE IGS SOLAR AT LEAST 30 DAYS' NOTICE IF YOU INTEND FOR SOMEONE TO ASSUME YOUR LEASE OBLIGATIONS You will provide IGS Solar the prospective Property RESIDENTIAL SOLAR EQUIPMENT LEASE AGREEMENT R�.SUS0722 FL Lease DocuSign Envelope ID: 88829760-BA9241C9-AC2E-E14819A6C72D buyer's contact information. IGS Solar will then determine if the buyer meets IGS Solar's credit requirements. If the buyer meets IGS Solar's credit requirements, you and your approved buyer will execute a written assignment of this Lease in a form approved by IGS Solar. You will execute all documents necessary to assign the Lease. Under an assignment approved by IGS Solar, your assignee will have all of your rights under this Lease and the Limited Warranty. C. IF YOU, YOUR ESTATE, OR HEIRS SELL THE PROPERTY and cannot comply with any of the options listed above, you will be in default under this Lease. D. EXCEPT AS SET FORTH IN THIS SECTION 1, you will not assign, sell, pledge, or in any other way transfer your interest in this Lease without IGS Solar's prior written consent, which will not be unreasonably withheld. A. ELECT TO RENEWby signing and returning the applicable forms at least 30 days before the expiration of the Term; or B. ELECT NOT TO RENEWby signing and returning the applicable forms at least 30 days before the expiration of the Lease, in which case this Lease will expire on the termination date; or C. IF YOU DO NOT RETURN THE FORMS, this Lease will automatically renew for additional terms of one year each, with the Lease Payments at the same amount as Contract Year 25 until: i. you give IGS Solar notice at least 30 days before a renewal term that you do not wish to renew; or ii. we send you a notice cancelling the automatic renewal. Upon expiration or termination of this Lease, if you have not renewed this Lease or purchased the System, IGS Solar may choose to remove the System and contact you to schedule a convenient time to have the System removed from your Property at no cost to you. If IGS Solar chooses not to remove the System, we will notify you in writing, and the System will be automatically conveyed to you AS -IS, WHERE IS, and you will become solely responsible for payment of all taxes, fees, and charges, if any, imposed in connection with the transfer of ownership of the System, Unless you are negligent or intentionally damage the System, IGS Solar will bear all of the risk of loss, damage, or theft of the System. If there is a loss affecting the System, you will continue to pay on time all Lease Payments and other amounts you owe under this Lease and cooperate with IGS Solar to have the System repaired or replaced. 1 � A UAQ 1i • '� +: You will be in default under this Lease if any of the following occur: A. YOU FAIL TO MAKE ANY PAYMENT when it is • - and such failure continuesfor • of i B. YOU FAIL TO PERFORM ANY MATERIAL OBLIGATION that you have undertaken in this Lease and such failure is (i) not capable of cure, or (ii) remains uncured for a period of 14 days after IGS Solar delivers written notice to you; G. YOU ALTER THE SYSTEM IN ANY WAY without first obtaining written consent from us; D. YOU PROVIDE FALSE OR MISLEADING INFORMATION TO US, E. YOU ASSIGN, TRANSFER, ENCUMBER, SUBLET, OR SELL THIS LEASE or any part of the System without first obtaining written consent from us; or R YOU BECOME A DEBTOR IN A BANKRUPTCY PROCEEDING, YOUR PROPERTY BECOMES SUBJECT T A FORECLOSURE PROCEEDING, or you become incapable of performing the obligations you have undertaken in this Lease; or G. YOU BREACH A REPRESENTATION OR WARRANTY MADE BY YOU IN THIS LEASE. If you are in default under this Lease, IGS Solar, a collection agency, and/or any other designated -third - party, may do any one or more of the following: • • • RESIDENTIAL SOLAR EQUIPMENT LEASE AGREEMENT RS.SL.CS. 0722 FL Lease �nnvSignEnvelope ID: 1C9-AC2E-E14819A6C72D B.TERMlNATE THIS LEASE AND: i require you to make the System available to IGS Solar for repossession, with the amount paid by |53 Solar for repossession being added to all other amounts you owe; or iirecover from you apayment equal twthe greater of the Minimum Purchase Price or the FM\( plus all taxes, late charges, and all other amounts you C.RECOVER DAMAGES FOR YOUR BREACH, including but not limited toLease Payments, late charges, and repayment or recapture of rebates, grants, credits, and other governmental payments ortax benefits caused byyour default; D. SUBMIT CORRECT INFORMATION REGARDING YOUR DEFAULT to credit reporti agencies; and i E.USE ANY OTHER REMEDY AVAILABLE TO |GS SOLAR IN THIS LEASE OR UNDER LAW bychoosing any one ormore ofthese remedies, |GSSolar does not give up its right touse any other remedy orLouse that same remedy inasubsequent default. Regarding your credit check in connection with the execution of this Lease, you hereby authorize |GS Solar A. OBTAIN YOUR CREDIT RATING from nationally recognized credit reporting agencies; B.D0SCLOSE THIS AND OTHER INFORMATION TOHGS SOLAR AFFILIATES AND ACTUAL OR PROSPECTIVE LENDERS, PINANCVNG PARTIES, INVESTORS, AND INSURERS; AND C.REPORT INFORMATION ABOUT YOUR ACCOUNT TOCREDIT BUREAUS. Late payments, missed payments, or other defaults on your account may be reflected in your credit report. IGS Solar b| k/ use or display any images of the System. IGS Solar or any of its affiliates may use the photographs of the System on their website or to show to other customers, investors, or other confidential partners. Your personal information will not be publicized, No hyi|ue to enforce any provision of this Lease will b deemed awaiver ofany right todoso, and noexpress waive, of any default will operate as a waiver of any other default urofthe same default onfuture occasion. This Lease will be governed by the applicable laws of the state where the Property is located, without regard to its rules for conflicts of law. All legal actions involving all disputes arising under this Lease will be brought exclusively in a court of the state or federal court in the county in which the Property is located. You and IGS Solar waive all of the rights to a trial by jury in any legal action related to this Lease. You will not join or consolidate claims in court as a representative or member of a class or in a private attorney general capacity. To be effective all notices under this Lease must be in writing and delivered delivery, electronic mail, overnight courier, or certified or registered mail tothe address listed for you onthe first page of this Lease. This Lease contains the entire agreement between you and |G3Solar regarding the in this Lease. There are noother agreements, written oral, between you and |G5 Solar regarding this Lease ovthe System, An changes to this Lease must be in a written amendment and signed by both you and |GCSolar. If any portion of this Lease is determined to be unenforceable by any court having jurisdiction, noother terms will beaffected, and the court will modify the unenforceable provision to the minimum extent necessary so as to render it enforceable. RESIDENTIAL SOLAR EQUIPMENT LEASE AGREEMENT RSSUS. 0722 FL Lease 9 DocuSign.Envelope ID: 88829760-BA92-41C9-AC2E-E14819A6C72D S ignature Page NOTICE OF RIGHT TO CANCEL: Wif ihWFCA DATE YOU SIGN THIS CONTRACT. SEE EXHIBIT 1, THE ATTACHED NOTICE OF CANCELLATION FORM, FOR AN EXPLANATION OF THIS RIGHT. E I have read this Lease and the Exhibits in their entirety. :u- RWWA-310 al"V-9ff0l I Ds Utility rates will change over time; therefore by leasing this equipment we cannot guarantee savings ��comparecl to your utility for any particular month or for the entire term of this Lease. DocuSigned by: Signature [—fy- �IW&Aere —F4296DB9F7F7426... Name (Print) RAUL R MOCETE Date 7/31/2023 IS SOLAR: Signature David Mrowzinski Date 7/31/2023 RESIDENTIAL SOLAR EOUIPMENT LEASE AGREEMENT 7 RS.SL.CS. 0722 FL Lease D,ocuBign Envelope ID: 88829760-BA9241C9-AC2E-E14819A6C72D 0 w Exhibit 1: Notice of Cancellation - Customer Copy I DATE OF TRANSACTION: 7/31/2023 You :Rn, without any penaltyor obligation,business days from•• Date of cancellation notice,. • any security interestarising out of the transaction will be canceled. If you cancel, you must make available to the seller at your residence, in substantially as good condition as wher, tf the seller regarding the return shipment of the goods at the seller's expense and risk. notice To cancel this transaction, mail or deliver a signed and dated copy of this cancellation notice or any other written notice, or send a telegram, to IGS Solar, LLC at 6100 Emerald Parkway, Dublin, Ohio 43016 or email SolarSupport@OGS.comnot later:.:midnight of business •x after • date of this transaction. MOCETEhereby cancel this transaction. lid ME RESIDENTIAL SOLAR EQUIPMENT LEASE AGREEMENT RS.SL.CS. 0722 FL Lease DocuSign Envelope ID: 88829760-QA92-41C9-AC2E-E14819A6C72D Exhibit lo, Notice of Cancellation - Customer Copy 2 DATE OF TRANSACTION: 7/31/2023 cancellation notice, and any security interest arising out of the transaction will be canceled. If you cancel, you must make available to the seller at your residence, in substantially as good condition as when if the seller regarding the return shipment of the goods at the seller's expense and risk. for performance of obligations un• To cancel this transaction, mail or deliver a signed and dated copy of this cancellation notice or any other written notice, or r a telegram,to IGS Solar,i I • Parkway, Dublin, • 43016 or email SolarSupport@IGS.comnot • • of business day after the date of this transaction. MOCETE herebytransaction. Signature am RESIDENTIAL SOLAR EQUIPMENT LEASE AGREEMENT 9 RS.SUS. 0722 FL Lease Exhibit Notice of Cancellation IGS Solar Copy I DATE OF TRANSACTION: 7/31/2023 • Mu caTcel,—,Tvf • E r t ` •4. aTV 09.de hv vou# - # i + . # , cancellation notice, and any security interest arising out of the transaction will be canceled. iTstructiOTS for performance ofall obligations :f To cancel this transaction, mail or deliver a signed and dated copy of this cancellation notice or any other written notice, or send a telegram, to IGS Solar, I-I-C at 6100 Emerald Parkway, Dublin, Ohio 43016 or email SolarSupport@)IGS.corn not later than midnight of the 7th business day after the date of this transaction. Signature M RESIDENTIAL SOLAR EQUIPMENT LEASE AGREEMENT 1 RS.SL.CS. 0722 FL Lease Exhibit 2.* Limited Warranty As part of the Lease, IGSSola Warranty for the System on your Property. This Limited Warranty will take effect when the System installation begins at your Property. This Limited Warranty will not apply if you purchase the System. A. SYSTEM WARRANTY The System will be professionally installed. During the Term, under normal use and service conditions, the System will befree from defects inworkmanship and breakdown ofmaterials orcomponents. B. ROOFTOP SYSTEMS WARRANTY If your System is a rooftop system, all of the penetrations will be watertight for a period of 5 years. A. OPERATION IGS Solar guarantees that during thehe System will operate within manufacturer's specifications, and if it does not, that IGS Solar will arrange to repair or replace any defective part and restore System operation. Any manufacturers' warranties applicable to the System are for the benefit of IGS Solar. Regardless of any other provision in this Lease, including its exhibits and addenda, IGS Solar does not guarantee that the System will produce a certain amount of kWh during the Term. B. MONITORING During the Tenn' unless you purchase the under Section 12 of the Lease we will provide our monitoring service at no additional cost. The monitoring system captures and displays historical power generation data and consists of hardware located onsite and software hosted by |GSSolar. |f the System isnot operating within normal ranges |GS So|ar's monitoring system will alert us and we will remedy any material issues that are covered under this Limited VVarmnty. |6S Solar may replace production monitoring devices to measure the energy produced by the System. Tumake aclaim under this Limited VVa you must provide detailed description of the problem by: i. Emai|ing8o|arSupport(cb|6S.cVm; ii Writing a letter and sending it via overnight mail Emeraldto 6100 Parkway, Dublin, OH 43016 - ATTN: IGS Residential Solar; or The contact information above may be updated periodically. |G6Solar will send you a notice if any of the contact information changes. Any notices under this Limited Wafrom |GSSolar will besent toyou at the Property address on the first page of the Leese or any subsequent address you provide |G5Solar. The limited warranties provided in this Exhibit do not apply to any repair, replacement, or correction required caused by any of the following: A. SOMEONE OTHER THAN UGS SOLAR'S APPROVED SERVICE PROVIDERS installed, removed, ne-instaUed.nrrepaired the System; B,DESTRWCTION OR DAMAGE TO THE SYSTEM orits ability tosafely generate electricity ifcaused byyou; C. A BREACH OF ANY OF YOUR OBLIGATIONS UNDER THE LEASE: E-ANY FORCE MAJEURE EVENT (as defined in Section 7ofthis Limited VVananty): F. SHADING FROM FOLIAGE that is new growth or is not kept trimmed to its appearance on the date the System was installed; G.ANY SYSTEM FAILURE NOT CAUSED BY A SYSTEM DEFECT. This Limited Warranty gives you specific rights, and you may also have other rights which vary from state to state. This Limited Warranty does not warrant any amount ofelectricity generation from the System excepL as set forth in Section 3(B) of this Limited Warranty. A.REPAIR OR REMOVAL f the System needsi ha h responsibility of IGS Solar under this Limited Warranty, or the System needs to be removed and reinstalled to facilitate re -roofing or other remodeling of your Property, you will have a qualified service provider approved by IGS Solar perform such repairs, removal, and reinstallation, all at your expense. During this time, you will continue to be responsible for all Lease If you do not purchaseihe System, and |GSSobr removes the System at the end ofthe Term, then |GS RESIDENTIAL SOLAR EQUIPMENT LEASE AGREEMENT RS.SL.CS. 0722 FL Lease 1E PocuSign Envelope ID: 88829760-BA924lC9-AC2E-El4819A6C72D Pursuant to Chapter 520, Part 11, Florida Statutes, this disclosure is designed to help you understand the terms and costs of your lease of a distributed energy generation system ("System"). It is not a substitute for the lease ("Lease") and other documents associated with this transaction. All information presented below is subject to the terms of your Lease. Name: Name: IGS Solar, LLC Momentum Solar 6100 Emerald Pwkwy, Dublin, OH 43016 6210 Hoff ner Ave Unit 100, Orlando, FL 32822 Phone Number: Phone Number: Email: I Email: License # (if applicable): State Contractor License #: N/A CVCS7036 Phone Number: I Email: State Contractor License #: N/A - IGS may retain an installer to perform all or part of the maintenance or warranty work Name: Mailing Address: 7097 Steer Blade Dr, Zephyrhills, FL 33541 RAUL R MOCETE System Location: 7097 Steer Blade Dr, Zephyrhills, FL 33541 Phone Number: Email: *NOTE: YOU ARE ENTERING INTO AN AGREEMENT TO LEASE A DISTRIBUTED ENERG GENERATION SYSTEM. YOU WILL LEASE (NOT OWN) THE SYSTEM INSTALLED ON YOU YOU ARE RESPONSIBLE FOR PROPERTY TAXES ON PROPERTY YOU OWN. CONSULT A T PROFESSIONAL TO UNDERSTAND ANY TAX LIABILITY OR ELIGIBILITY FOR ANY TA CREDITS THAT MAY RESULT FROM THE PURCHASE OF YOUR DISTRIBUTED ENERG] For additional information, please carefully read Chapter 520, Part 11, Florida Statutes. QocuSign Envelope to: 88829760-BA924lC9-AC2E-El4819A6C72D Description System: ------------ A residential solar photovoltaic system, comprised of modules, racking, inverters, and other equipment System Size: 14.8 kW monitoring equipment: Enphase additional equipment: U4A Total cost to be paid, including The initial term of Lease: Total of all your monthly any interest, installation fees, payments and estimated document preparation fees, 1� _�_5 Years taxes over the course of service fees or other F-1 Months Lease: N/A fees: Your monthly payment $ 79,600.23 $79.600.23 during the term of your Lease: $ �184.34 Your estimated total Lease payments over the initial term State or federal tax incentive(s) or of the Lease excluding taxes rebate(s) relied upon by lessor in determining the price of the Number of Lease payments: Federal Investment Tax Credit Value of Incentive/Rebates *NOTE: You may not be eligible for all incentives available in your area. Consult your tax professional or legal professional for further information. For additional information, please carefully read Chapter 520, Part 11, Florida Statutes. DocuSign Envelope ID: 88829760-BA92-41C9-AC2E-E14819A6C72D El If a payment is more than - days late, you will be charged $ OR Late payments accrue interest at 1.50 % monthIly not to exceed the maximum allowable by law. Market Price for removal _s — timated System Removal Fee:$ services at time of removal Maintenance Fee: $ o UCC Notice Removal and Re -filing Fee: �f you refinance your mortgage, you may have to pay $ Q Returned Checks: If any check or withdrawal right is returned or refused by your bank, you may be charged $ (or a lower amount if required by law) Non -Connection to Internet: It you do hot maintain 65-5`§T�-­Speed internet connection, you will be charged a monthly fee of $0 and/or your monthly payments may be based upon estimates. Non -connection may affect any guarantee. See Section 0. Amount you owe at Lease signing: $ Q Amount you owe at the commencement of installation: $ Q Amount you owe at the completion of installation: $_0 You will make a final payment to Lessor in the amount of $ 0 at the following time (e.g., interconnection): You will receive: Approximate Completion Date: 1 Electronic Invoices 30 days from the date (sent to your email address of the commencement o above) construction of the system El Paper Invoices (sent to your mailing address above) For additional information, please carefully read Chapter 520, Part 11, Florida Statutes. DocuSigr, Envelope ID: 88829760-BA92-4lC9-AC2E-El4819A6C72D For additional information, please carefully read Chapter 520, Part 11, Florida Statutes. PocuSign Envelope ID: 88829760-BA92-41C9-AC2E-E14819A6C72D Ix-1 Credit check on the purchaser(s) by the Lessor * Minimum FICO score requirement: rqn * Transfer fee of $ ®Assumptions of Agreement by purchaser(s) El Other If you sell your home, you El ARE 1� ARE NOT permitted to transfer the System to a new home or property. You may also have the option(s) to purchase the System or prepay some or all of the Lease Balan as part of or prior to a transfer, as long as you are not in default of the Lease. The purchase price will be the greater of (a) the minimum purchase price ("Minimum Purchase Price") or the fair marke value ("FIVIV) of the System. The Minimum Purchase Price will be an amount equal to the will be equal to the present value of the forecasted lease payments over the Term then remaining, discounted at a rate of 5%. The FMV will be calculated by a mutually acceptable third -party independent appraiser. El System guarantees or warranties El ARE El ARE NOT rendered void F-1 Provider is not responsible or liable for any loss or damage that may occur as a result of any modifications Fx]Other You will be in default of this lease Your Lease may be assigned, sold or transferred by Lessor without your consent to a third -party who will be bound to all the terms of the Lease. If such a transfer occurs, you will be notified if this will change the address or phone number to use for Lease questions, payments, maintenance or repair requests. VEMEM El System performance or electricity production guarantee 0 Other type of System guarantee* 4 No System guarantee I INTRUffly 1111 1 - - For additional information, please carefully read Chapter 520, Part 11, Florida Statutes. PocuSign Envelope ID: 88829760-BA92-41C9-AC2E-E14819A6C72D You Q HAVE El HAVE NOT been provided with a savings estimate ("Estimate") based on your Lease. If you HAVE been provided with an Estimate, Lessor provides the following: Lessor 1:1 IS Y IS NOT guaranteeing these savings. Your Estimate was calculated based on: X Your estimated prior electricity use El Your actual prior electricity use El Your estimated future electricity use Your Estimate assumes the following: IR Years of electricity production from the System: 25 R A current estimated utility electricity rate of .171 [cost per kilowatt-hour] during the first Lease year with estimated increases Of 3.90 percent annually. Lessor based this estimate on the following source(s): X Your utility will continue to credit you for excess energy your System generates at El ESTIMATED FUTURE N CURRENT utility electricity rates NOTE: It is important to understand that future electric utility rates are estimates only. Your future electric utility rates and actual savings may vary. For further information regarding rates, you may contact your local utility or the public regulation commission. Tax and other state and federal incentives are subject to change or termination by executive, legislative or regulatory action, which may impact savings estimates. Please read your Lease carefully for more details. You have the right to terminate this Lease without penalty within Z business days after the agreement is signed by both parties by notifying Lessor in writing at the above address. NOTE: This section does not apply IF agreement is to lease a distributed energy generation syste in a solar community in which the entire community has been marketed as a solar community and of the homes in the community are intended to have a distributed energy generation system, orl solar community in which the developer has incorporated solar technology for purposes meeting the Florida Building Code in s. 553.73, F.S. i For additional information, please carefully read Chapter 520, Part 11, Florida Statutes. DocuSign Envelope ID: 88829760-BA9241C9-AC2E-E14819A6C72D E3 Lessor will not insure for any loss or damage to the System. IR Lessor will insure System for any loss or damage, except under the following circumstances: Damage or loss caused by your gross negligence or you intentionally damage the system. NOTE: Customers with asterns greater than 10kW are required to obtain general liability insurance for personal and property damage in the amount of up to $1 million dollars, as determined by the utility, in order to be approved for interconnection. Mixi A - 1141611111W 41"IMM, U W" 11111106*1*61111*1*1 1(g Mra 0 0 Lessor will procure and maintain personal property insurance on the System in an amount equal tit. the cost to replace the System. Other Important Terms: See your Lease for additional information regarding early ' purchase options, maintenance, responsibilities, warranties, and late and default charges. Individual Completing this Form: Docuftned by: R M Name: RAUL QUIE Signature: [—;W ;'Z-m&Mre �F4296DBW7F7426 Title: Homeowner Company: N/A Date: 7/31/2023 For additional information, please carefully read Chapter 520, Part 11, Florida Statutes. I Envelope Id: 88829760BA924IC9AC2EE14819A6C72D Subject: Signature Required For Lease &it; 1 FCCT7J&gt; Source Envelope: Document Pages: 19 Signatures: 2 Certificate Pages: 5 Initials: 1 AutoNav: Enabled Envelopeld Stamping: Enabled Time Zone: (UTC-05:00) Eastern Time (US & Canada) Status: Completed Envelope Originator: Solar Support 6100 Emerald Pkwy Dublin, OH 43016 Record Trilteking Status: Original Holder: Solar Support Location: DocuSign 7/31/2023 9:59:28 PM SolarSupport@igssolarpower.com �•i rauirmocetel@gmaii.com Security Level: Email, Account Authentication (None), Authentication ft-d by: �Z"Mere Ea?U F0"u 4,,,D,,F,F742,., Signature Adoption: Pre -selected Style Using IP Address: 104.137.118.32 Signed using mobile Authentication Details SMS Auth: Transaction: f602l836-6b2f-4902-9b97-e3f849c628d6 Result: passed Vendor ID: TeleSign Type: SMSAuth Performed: 7/31/2023 10:01:19 PM Phone: +1 813-330-9183 Electronic Record and Signature Disclosure: Accepted: 7/31/2023 10:01:30 PM ID: 19f02O46-daae-441c-8dO4-5bO3608dl47e Company Name: IGS Solar, LLC Sent: 7/31/2023 9:59:31 PM Viewed: 7/31/2023 10:01:30 PM Signed: 7/31/2023 10:17:20 PM In Person Signer Events Signature Titnestamp Agent Delivery Events Status Timestamp Intermedlary'0611vOry Events status Tiniest nip michael Murrell E::� michael.murrell@momentumsolar.com § PI ED c Security Level: Email, Account Authentication (None) Electronic Record and Signature Disclosure: Not Offered via DocuSign Operations IGSContracts@MomentumSolar.com Security Level: Email, Account Authentication (None) Electronic Record and Signature Disclosure: Sent: 7/31/2023 10:17:23 PM Sent: 7/31/2023 10:17:24 PM Not Offered via DocuSign Solar Support SolarSupport@igssolarpower.com IED Senior Director IGS Solar Security Level: Email, Account Authentication (None) Electronic Record and Signature Disclosure: Not Offered via DocuSign Envelope Sent Hashed/Encrypted Certified Delivered Security Checked Signing Complete Security Checked Completed Security Checked Sent: 7131/2023 10:17:24 PM 7/31/2023 9:59:31 PM 7/3112023 10:01:30 PM 7/31/2023 10:17:20 PM 7/31/2023 10:17:24 PM Payment Events Status Timostamps, Electronic Record and Signature Disclosure created on: 4/1612021 4:58:43 PM Parties agreed to: RAUL R MOCETE ELECTRONIC RECORD AND SIGNATURE DISCLOSURE From time to time, IGS Solar, LLC (we, us or Company) may be required by law to provide to you certain written notices or disclosures. Described below are the terms and conditions for providing to you such notices and disclosures electronically through your DocuSign, Inc. (DocuSign) Express user account. Please read the information below carefully and thoroughly, and if you can access this information electronically to your satisfaction and agree to these terms and conditions, please confirm your agreement by clicking the 'I agree' button at the bottom of this document. Getting paper copies: At any time, you may request from us a paper copy of any record provided or made available electronically to you by us. For such copies, as long as you are an authorized user of the DocuSign system you will have the ability to download and print any documents we send to you through your DocuSign user account for a limited period of time (usually 30 days) after such documents are first sent to you. After such time, if you wish for us to send you paper copies of any such documents from our office to you, you will be charged a $0.00 per -page fee. You may request delivery of such paper copies from us by following the procedure described below. Withdrawing your consent: If you decide to receive notices and disclosures from us electronically, you may at any time change your mind and tell us that thereafter you want to receive required notices and disclosures only in paper format. How you must inform us of your decision to receive future notices and disclosure in paper format and withdraw your consent to receive notices and disclosures electronically is described below. Consequences of changing your mind: If you elect to receive required notices and disclosures only in paper format, it will slow the speed at which we can complete certain steps in transactions with you and delivering services to you because we will need first to send the required notices or disclosures to you in paper format, and then wait until we receive back from you your acknowledgment of your receipt of such paper notices or disclosures. To indicate to us that you are changing your mind, you must withdraw your consent using the DocuSign 'Withdraw Consent' form on the signing page of your DocuSign account. This will indicate to us that you have withdrawn your consent to receive required notices and disclosures electronically from us and you will no longer be able to use your DocuSign Express user account to receive required notices and consents electronically from us or to sign electronically documents from us. All notices and disclosures will be sent to you electronically. Unless you tell us otherwise in accordance with the procedures described herein, we will provide electronically to you through your DocuSign user account all required notices, disclosures, authorizations, acknowledgements, and other documents that are required to be provided or made available to you during the course of our relationship with you. To reduce the chance of you inadvertently not receiving any notice or disclosure, we prefer to provide all of the required notices and disclosures to you by the same method and to the same address that you have given us. Thus, you can receive all the disclosures and notices electronically or in paper fon-nat through the paper mail delivery system. If you do not agree with this process, please let us know as described below. Please also see the paragraph immediately above that describes the consequences of your electing not to receive delivery of the notices and disclosures electronically from us. How to contact IGS Solar, LLC: You may contact us to let us know of your changes as to how we may contact you electronically, to request paper copies of certain information from us, and to withdraw your prior consent to receive notices and disclosures electronically as follows: To advise IGS Solar, LLC of your new e-mail address: To let us know of a change in your e- mail address where we should send notices and disclosures electronically to you, you must send an email message to us at customersupport@igs.com and in the body of such request you must state: your previous e-mail address, your new e-mail address. In addition, you must notify DocuSign, Inc to arrange for your new email address to be reflected in your DocuSign account by following the process for changing e-mail in DocuSign. To request paper copies from IGS Solar, LLC: To request delivery from us of paper copies of the notices and disclosures previously provided by us to you electronically, you must send us an e-mail to customersupport agigs.com and in the body of such request you must state your e-mail address, full name, US Postal address, and telephone number. To withdraw your consent with IGS Solar, LLC: To inform us that you no longer want to receive future notices and disclosures in electronic format you may: i. decline to sign a document from within your DocuSign account, and on the subsequent page, select the check -box indicating you wish to withdraw your consent, or you may; ii. send us an e-mail to eustomersupport@igs.com and in the body of such request you must state your e-mail, full name, IS Postal Address, telephone number, and account number. Required hardware and software: Operating Systems: Windows2000? or WindowsXP? Browsers for ( Internet Explorer 6.0? or above SENDERS): . ............ _.__., _........�_ Browsers (for SIGNERS): !Internet Explorer 6.0?, Mozilla FireFox 1.0, NetScape 7.2 (or above) Email: -------- _ _w _...___ .,� ... ___ ;Access to a valid email account _ ____ _..... _ . _ Screen Resolution: 1800 x 600 minimum Enabled Security, ?* Allow per session cookies Settings: Users accessing the internet behind a Proxy Server must enable HTTP `11.1 settings via proxy connection ** These minimum requirements are subject to change. If these requirements change, we will provide you with an email message at the email address we have on file for you at that time providing you with the revised hardware and software requirements, at which time you will have the right to withdraw your consent. Acknowledging your access and consent to receive materials electronically: To confirm to us that you can access this information electronically, which will be similar to other electronic notices and disclosures that we will provide to you, please verify that you were able to read this electronic disclosure and that you also were able to print on paper or electronically save this page for your future reference and access or that you were able to e-mail this disclosure and consent to an address where you will be able to print on paper or save it for your future reference and access. Further, if you consent to receiving notices and disclosures exclusively in electronic format on the terms and conditions described above, please let us know by clicking the 'I agree' button below. By checking the 'I Agree' box, I confirm that: I can access and read this Electronic CONSENT TO ELECTRONIC RECEIPT OF ELECTRONIC RECORD AND SIGNATURE DISCLOSURES document; and I can print on paper the disclosure or save or send the disclosure to a place where I can print it, for future reference and access; and Until or unless I notify IGS Solar, LLC as described above, I consent to receive from exclusively through electronic means all notices, disclosures, authorizations, acknowledgements, and other documents that are required to be provided or made available to me by IGS Solar, LLC during the course of my relationship with you. SYSTEM INFORMATION INVERTER « a:` ROOFTECH ' ` «IZON 2—RAIL RACKING SYSTE�I IIIMSIZE I lu ) 28.2603158,-82.2241589 ROOF SHALL MORE # LAYERS OF COVERING ADDITION # THE SOLAR EQUIPMENT. A Wei :A # =01 Z;r_lvsj#f «' • h A. t t s• t `i CLIMATIC 4 GEOGRAPHIC CRITERIA TABLE r f SPEED TOPOGRAPHIC EFFEC« SPECIAL REGION WIND BORNE r1 « 7 SEISMIC DESIGN CATEGORY CLIMATE ZONE WIND EXPOSURE CATETORY FBC, RESIDENTIAL IAL 2020 TABLE 3U1.2.1.3 WIND SPEED CONVERSIONSa vult 1110 115 120 130 140 150 160 170 180 190 k00 Vasil 85 89 1 93 101 108 116 124 132 139 147 155 For SI: 1 mile per hour = 0.447m/s. a. Linear interpola Jon is permitted. a +!" arIIC .� r i s+# 400 WATTMODULE DATASHE Tj M a � COVER PAGE « ATTACHMENT DETAIL « ATTACHMENT DETAIL « PANELLAYOUT ELETRCAL r'��ELETRICAL# 'I` CEQUIPMENTI LABELS BILL OF MATERIALS MODULES 37 INVERTERS 37 L-FOOT ATTACHMENT W/ RT-MINI 78 171" RAILS 17 SKIRTS 0 ENPHASE COMBINER BOX 1 EATON 60A FUSIBLE AC DISCONNECT 1 60A FUSES 2 60A BACKFEED BREAKER 1 momentum0 SOLAR PR • « • s •SOLAR 325 HIGH STREET, METUCHEN, NJ r r MOMENTUMSOLAP.COM PROFESSIONAL : « ## fi ENGINEERING CAMERON CHRISTENSEN CERTIFIED SOLAR CONTRACTOR LICENSE NUMBER: CVC57036 MOMENTUM SOLAR 5728 MAIOR BLVD. SUITE 307, ORLANDO FL. 32$19 SYSTEM SIZE (DC): 14.8 KW 37 MODULES: HANWHA Q.PEAK DUO BLK ML-C 10+ 400 37 INVERTERS: ENPHASE IQPLUS-72-2-US PR03ECT INIFORt4ATION INITIAL DATE: 8/21/2023 1 DESIGNER:3T lEm �NXT HORIZON RAIL 84" MILL NXT HORIZON RAIL 168" DARK m NXT HORIZON RAIL 208" MILL NXT HORIZON RAIL 208- DARK NXT HORIZON RAIL 246" MILL E �NXT H�ORIZON RAIL 246' wUNIRAC 1411 BROADWAY BLVD. NE PHONE: 505,242?.6411 WWW.UNIRAC.COM NXT HORJIZON IgRijklijin NXT HORIZON RA IL SPI ME DRAWING NOT TO SCALE ALL DIMENSIONS ME Emu NIRAC WMINAL as 1411 BROADWAY BLVD. NE w I oil MY# tIL SPLICE got 9/22/2021 E DRAWING NOT TO SCALE ALL DIMENSIONS ARE NOMINAL ■1 III ii momentum SOLAR PRO CUSTOM SOLAR LLC D.8,A. MOMENTUM SOLAR 325 HIGH STREET, METUCHEN, N3 08840 (732) 902-6224 MOMENTUMSOLAR.COM CAMERON CHRISTENSEN CERTIFIED SOLAR CONTRACTOR LICENSE NUMBER: CVC57036 MOMENTUM SOLAR 5728 MAJOR BLVD. SUITE 307, ORLANDO FL. 32 a ML-G10+ 400 37 INVERTERS: ENPHASE IQ8PLUS-72-2-US F:rZW nc 0 m J O co o ' F � ° I t9a w w w �— t- cc V �C 007 ,S % wp '} �^ '• r mLjj pmmw OM w w w IL0 70 Z si }.. � ( . �.y N 0 z m Qom �p S,gir Ay MN Rl (� N �3 wa tX Kf *•v" < uj uj ft- _Qwa v °° �p��, N gb ",� ptlPp, �`�' o 4e,N 4yJ ,wN �' G�9 Q Gam] m ..< Cf :E 0 U o ttf'iii4�0 W F-0C?>_a 06 Fie] LZ^4z\i10 --wI0s .xQj t9�09-S£6 (999) :9-4d �a �W� 6 Lt_ m 846 (soe{ i oo�Twv (got) nu l£ L Z6 'V� °06010 UoS c 11,, (Gi�V1 :Aq 'tp (6699 W 3) 94TEE VOINfl`t� 11AIV4N4 C!£Z apnS }aaajS DUaOJ OZ90G 1 � � 04 +� oc 3."ns '3Alac i3sNn 6 1 ! IN3 4'l3A3a.1onclow V SH33NION3 4a! y � � _ .� �tcv�� �aJ �— Q+c! A� Q �'�11� Y3LS lSNI� Niti3W Ad d01QQ2� II INIW -1# uo1a�0�a p o_u _ w .SUQt$IAa.! 4Z^•£Z-£0 .94ttP Ta ____m 111l44 tll1t�f ..° uq INN f fill 19 77 T= _ cli Ns 0 0 1 0 �e 1 { LL w N 4 Q A pm z X U) z ego a kaA 4 i \ ILI 0 i -�"" 2 it t R;, 0 bi wcv 10 w { 4 ttf 0 a I J W M N N co (n In j ?z M 1 1 N W W ~M 1 ( jQW-, W .i. m,.,.____® F to, J Jtal � n � 0 L CD � ' �L z iL SCALE: 3/3211 = 11—Off LANDSCAPE MAX SPAN PORTRAIT MAX SPAN LANDSCAPE MAX PORTRAIT MAX ROOF PANEL COUNT TILT AZIMUTH SHADING (ROOF AREA 1/2/3) (ROOF AREA 1/2/3) CANTILEVER CANTILEVER Rl 37 21* 187* 97% 48 /32 /32 48 /32 /32 16 /10 /10 16 /10 /10 ELECTRICAL EQUIPMENT Ilk- LU U DRIVEWAY z LU cc 3'-0" LU ry co U_ 0 cc z 0 U_ Dal CLAMPING MAX SPACING IN ZONE 1 72" O.0 AND IN ZONE 2 AND ZONE 3 48" O.0 NOTE: 1. ROOF COVERING MATERIAL IS COMPOSED OF SINGLE LAYER ASPHALT COMPOSITE SHINGLE, 2. REFER TO LAYOUT DETAIL DRAWING PV-3 FOR ALL ROOFTOP DIMENSIONS. gm 01 momentum SOLAR PRO CUSTOM SOLAR LLC D.B.A. MOMENTUM SOLAR 325 HIGH STREET, METUCHEN, NJ 08840 (732) 902-6224 MOMENTUMSOLAR.COM PROFESSIONAL ENGINEERING TOTAL SQUARE FOOTAGE OF ROOF: 4373 SOFT FOOTAGE OF SOLAR ARRAY:781.48 SQFT SOLAR CONTRACTOR RIDGESQUARE PERCENTAGE OF SOLAR ROOF COVERAGE: 17.88% CAMERON C CERTIFIED SOLAR CONTRACTORHRISTENSEN LICENSE NUMBER: CVC57036 18" RIDGE SETBACK SHALL BE REQUIRED MOMENTUMSOLAR 5728 MAJOR BLVD. SUITE 307, ORLANDO FL. 32819 CUSTOMER INFORMATION SYMBOL LEGEND RAUL MOCETE - MS133709 7097 STEER BLADE DR 3'-C" MAIN SERVICE PANEL CHIMNEY Fm;pl 19, ZEPHYRHILLS, FL 33541 18133309183 E!V SYNIEM INFO RMATION E SUB -PANEL z SKYLIGHT SYSTEM SIZE (DC): 14.8 KW 37 MODULES: HANWHA Q.PEAK DUO BLK 01 UTILITY METER VENT z M -G 10+ 400 37LINVERTERS: ENPHASE IQBPLUS-72-2-US AC AC DISCONNECT 0 PIPE VENT DISC FAN UDC UTILITY DISCONNECT 'D ElLOAD CENTER SATELLITE DISH PR031ECT INFORMATION NEMA 3R BOX W1 ENVOY-S FIRE SETBACKS INITIAL DATE: 8/21/2023 DESIGNER: IT REV: DATE: DESIGNER: COMBINER BOX MIN 3' X3'GROUND ACCESS CBCOMBINER REV: DATE: DESIGNER: ROOF LAYOUT Fa MODULE PITCH DIRECTION WIND PRESSURE ZONE LINES. REFER TO PV-2.2 FOR ADDITIONAL INFO r v- PV MODULE RATINGS INVERTER RATINGS VOLTAGE DROP CALCULATIONS MODULE MAKE HANWHA INVERTER MAKE ENPHASE FORMULA USED PER NEC HANDBOOK 215.2(A)(4) WHERE APPLICABLE momentum MODEL Q.PEAK DUO BLK MODEL IQ8PLUS-72-2- WIRE RUN VMP IMP R L (FT) VD % Vo WIRE SIZE ML-G10+ 400 SOLAR MAX POWER 40OW MAX OUTPUT POWER 29OW BRANCH TO ]-BOX 240.00 15.73 1.98 85.58 5.331 2.22% 12 AWG PRO CUSTOM SOLAR LLC D.B.A. MOMENTUM SOLAR OPEN CIRCUIT VOLTAGE 45.3V OPEN DC VOLTAGE 60V J-BOX TO LOAD 240.00 44.77 1.24 50.00 5.551 2.31% 10 AWG 3zs Micro STREET, ME-6224 , N� os8ao CENTER TENT MSOL R. MOMENTUMSD .coM MPP VOLTAGE 37.13V NOMINAL AC VOLTAGE 240V LOAD CENTER TO AC PROFESSIONAL SHORT CIRCUIT CURRENT 11.14A DISCONNECT 240A0 55.9625 fl.491 3.0fl 0.165 0.07/ 06 AWG MAX AC CURRENT 1.21AENGINEERING' MPP CURRENT 10.77A AC DISCONNECT TO CEC INVERTER EFFICIENCY 97% 240.00 55.9625 0.491 10.00 0.550 0.23°� 06 AWG NUMBER OF MODULES 37 INTERCONNECTION NUMBER OF INVERTERS 37 UL1703 COMPLIANT YES PV BI%=AfZ=n 1703 COMPLIANT YES NECy+ {5gp:�3 ryry 2�"g�; R S,. ffir5 ,i".2�E�2If'�d i1'""Y .b,15.1 �It3 RULE SUB PANEL # OF MODULES PER BRANCH THIS SOLAR PHOTOVOLTAIC SYSTEM COMPLIES WITH THE 2020 (1,25 x INVERTER OUTPUT) + MAIN OCP � BUS RATING x 1.2 BREAKER SIZE FLORIDA BUILDING CODE AND THE 2017 NATIONAL ELECTRICAL CODE UP TO 16 20A i1.25 x 4.77, + 175 i5 269 x 1.2 CERTIFICATIONFSEC : PER FL. STATUE 377.705 , I MINA A. MA R PE# 86753 37 HANWHA Q.PEAK DUO BLK ML-G10+ 400 40OW MODULES PAIRED WITH CERTIFICATE OF AUTHORIZATION #33404, AN ENGINEER 37 ENPHASE IQ8PLUS-72-2-US MICRO -INVERTERS LICENSED PURSUANT TO CHAPTER 471,CERTIFY THAT THE PV ELECTRICAL SYSTEM AND ELECTRICAL COMPONENTS ARE= DESIGNED AND APPROVED USING THE STANDARDS CONTAINED �. IN THE MOST RECENT VERSION OF THE FLORIDA BUILDING BRANCH CIRCUIT A CODE. FBC 2020 A 13 MICRO -INVERTERS EXISTING SQUARED �` 9 BRANCH CIRCUIT B UTILITY 225A SUB PANEL 240 V 12 MICRO -INVERTERS METER 0° BRANCH CIRCUIT C ; " .PLORIV 12 MICRO -INVERTERS GRID -' , ... _ lolls INH I ENPHASE 80A �'r IOA le;\\� AC COMBINER + BOX SOLAR CIRCUIT DISCONNECTING MEANS ■ • EATON 60A FUSIBLE AC I I DISCONNECT r j 8 SOLAR NT R n 175A CAM£RDN crisusfNs£N CERTIFIED SOLAR CONTRACTOR LICENSE NUMBER: CVC57036 .._.„.._._._.-._: ,_..�..- ... ,.... ..._. ,ram.,! A 64A .,„.�.. MOMENTUM SOLAR ,5728 MAIOR BLVD. SUITE 307, ORLANDO FL. 32819 _a_.. _ ,_ _._�. _ . CUSTOMER INEOR ATION ROOF I OA/15A BREAKER --- POWER RAUL MOCETE - MS133709 JUNCTION (MANUFACTURER 60A FUSES GROUND 7097 STEER BLADE DR SUPPLIED FOR ZEPHYRHILLS, FL 33541 TERMINATION CAP 1 BOX 2A-C ENVOY) 3 3 EXISTING 200A INSTALLED ON 20A BREAKER (A) METER MAIN P ,� TEM 1 091�3MA SOLAR INSTALLER NOTES: END OF CABLE. 20A BREAKER (B) NEW 175A BREAKER SYSTEM SIZE (DC): 14.8 KW DE ATE MAIN BREAKER IN METER MAIN 20A BREAKER (C) 37 MODULES: HANWHA Q.PEAK DUO BLK FROM 20 A TO 175A ML-G10+ 400 37 INVERTERS: ENPHASE Wire Temp. ire Temp. Conduit Derated InverterNEC Design Ground Ground ire IQ8PLUS-72-2-US Wire Tag Conduit Wire Cl y Gauge Wire Type Rating Ampacity (A) Derate Fill Derate Ampacity (A) ty NOC {A� Correction Current (A) Size Type 1 OPEN AIR 3 12 AWG Trunk Cable 90°C 30 0.96 1 28.80 13 1.21 1.25 19.66 12 AWG Trunk Cable 2A 10 AWG THWN-2 75'C 35 0.96 26.88 13 1.21 1.25 19.66 _.__.....---PROJECT INF004AT ON ',' 2B 3/4" PVC 6 10 AWG THWN-2 75°C 35 0.96 0.8 26,88 12 1.21 1.25 18A5 08 AWG THWN-2 INITIAL DATE: 8/21/2023 DESIGNER:JT REV: DATE: DESIGNER: 2C 10 AWG THWN-2 75°C 35 0.96 26.88 12 1.21 1.25 18.15 REV: DATE: DESIGNER: 3 3/4" PVC 3 + G 06 AWG THWN-2 75°C 65 0.96 1 iL 37 1.21 1.25 55.96 08 AWG THWN-2 THREE LINEDIAGRAM NOTE: LETTER "G" IN WIRE QTY TAB STANDS FOR GROUNDING CONDUCTOR. t C i 3 t COEFFICIENTS. C THE ENTIRE ARRAY IS BONDED ACCORDING TO (NEC 690.46 - 250.120 PARAGRAPH C). THE GROUND IS CARRIED AWAY FROM THE GROUNDING LUG USING #6 BARE COPPER WIRE OR #8 THWN-2 COPPER i 7. INVERTER iC (NOMINAL i" OBTAINED ' i' EQUIPMENTDATASHEET 8. CONTRACTOR SHALL BE RESPONSIBLE FOR COMPLYING WITH ALL LOCAL AND NATIONAL CODEREQUIREMENTS. 9. EACH MODULE MUST BE GROUNDED ACCORDING TO USER INSTRUCTIOUS '111m,It , iNwaus«#M 11. PER NEC 690.13,690.15, PROVIDE A WARNING SIGN AT ALL LOCATIONS WHERE TERMINALS DISCONNECTING 4 MAY ENERGIZED IN THE OPEN POSITION> SIGN SHALL READ*WARNING ELECTRIC SHOCK HAZARD i# NOT TOUCHx OR EQUIVALENT. SHOWING12. PER NEC 705.10, PROVIDE A PERMANENT PLAQUE OR DIRECTORY ALL ELECTRIC POWER SOURCESON 4 SERVICE ENTRANCE. 13. INTERCONNECTION iD SHALL COMPLY# 14. AND OPTION #' * SINGLE CIRCUIT BRANCH TO BE SPLIT INTO TWO SUB -CIRCUIT BRANCHES IS t; 15. ALL CONDUCTORS irr NEUTRAL16. • EQUIPMENT GROUNDINGi ! i' BONDED 17. EQUIPMENT GROUNDING i,t it IS CONNECTED TO GROUNDING ELEC`ii # t i 18. FUSES FOR PV DISCONNECT A AIC RATINGS OF ## . AC AND 20KA DC. • SUPPLY SIDECONNECTION 3 MADE USING ILSi INSULATION PIERCING CONNECTORS (IPC). MAKE, MODEL, AND RATING OF INTERCONNECTION A ON *BELOW. # METHOD OF i # 21, UTILITY HAS 24-HR UNRESTRICTED ACCESS TO ALL PHOTOVOLTAIC SYSTEM COMPONENTS • d i AT THE SERVICE ENTRANCE. WORKING22. A' AROUND THE EXISTING AND NEW ELECTRICALEQUIPMENT BE MAINTAINED IN ACCORDANCE #: 23. CONDUCTORS EXPOSED TO SUNLIGHT SHALL BE LISTED AS SUNLIGHT RESISTANT PER 24. CONDUCTORS EXPOSED TO WET LOCATIONS SHALL BE SUITABLE FOR USE IN WET LOCATIONS PER NEC ARTICLE # TOTAL25. AREA OALL i" i is SPLICES, AND TAPS AT ANY CROSS SECTIONOF 'ING DOES NOT) OF ' iSS SECTIONAL AREA t OF THE SPACE. Y s SYSTEM IS CONSIDERED AN AC MODULENO DC CONDUCTORS CONDUIT, COMBINER,# BOX, DISCONNECT. ! COMPLIES WITH 690.6 DISCONNECT AND ASSOCIATED DC LABELING ARE REQUIRED. 27. SYSTEM COMPLIES WITH 690.12 RAPID SHUTDOWN AND ASSOCIATED LABELING AS PER 690.56(C). AC VOLTAGE AND SYSTEM OPERATING CURRENT SHALL BE PROVIDED 690.52. s CONDUCTORS IN CONDUITAC CONDUCTORSBRANCH AND NOT PV SOURCE690.6. 29. ALL GROUNDING SHALL COMPLY WITH 690.47(A) IN THAT THE AC MODULES WILL COMPLY WITH ,. 30. NO TERMINALS SHALL BE ENERGIZED IN THE OPEN POSITION IN THIS AC MODULE SYSTEM •` #•i •*# 31. WHERE APPLICABLE: INTERCONNECTION SHALL COMPLY WITH 705.12(A) OR 705.12(B) ' A A Iowa. #' '# ' T F1.1 1 i • 4It 16MM-11H MiZIMM IN 10 MRIMM920i. A i • 3 N-,fililM5Q&jlVlN r FIGURE 1: ADJUST THE CONNECTOR NUT TO SUITABLE# t ::# 2. PUT THE BRANCH WIRE i THE CAP 3. INSERT THE MAIN WIRE, IF THERE SHEATH FULLY i LAYS OF i LAY IN THE CABLE,MAIN i t STRIP A CERTAIN LENGTH OF THE FIRST INSULATED LAY FROM D 4. TURN THE NUT BY HAND, i FIX THE CONNECTOR SUITABLE LOCATION. 5. SCREW THE NUT WITH THE SLEEVE SPANNER. 6. SCREW THE NUT CONTINUALLY UNTIL THE TOP PART IS CRACKED AND DROPPED DOWN momentum SOLAR r CUSTOM SOLARD.B.A.•SOLAR 325 HIGH STREET, METUCHEN, NJ 0,,,0 224 4 y~. • II IIA I I ■ II■III � PROFESSIONAL py{ tw CERTIFIED SOLAR CONTRACTOR LICENSE NUMBER: CVC57036 MOMENTUM SOLAR 5728 MAIOR BLVD. SUITE 307, ORLANDO FL. 32819 V*W#411 d!; i 'a Michael S. Rezk Engineer -PE Pro Custom Solar LLC 732-902-6224 3096B Hamilton Blvd August 21, 2023 South Plainfield, NJ 07080 Re: Proposed Photovoltaic Solar Panel Installation Raul Mocete 7097 STEER BLADE DR ZEPHYRHILLS, FL 33541 Dear Plan Reviewer: Certification: I have reviewed the engineering testing reports for the racking and attachments to be used on this project Z� and I certify that the products are capable of supporting the code required loads and are suitable for this installation when installed in strict compliance with the manufacturers printed instructions. Regarding the solar panel array installation on the above referenced project please note that an inspection was performed by a representative of the Architect/Engineer of Record, and analysis of the existing structure was conducted. There is adequate structural capacity for the installation of the array with the following recommendations: 1. The array will be installed on the existing roof. The roof framing is constructed of 2"W' wood trusses @24" o.c. spanning 23' 11 " with a top chord length of 26'with intermediate supports at 1/4th points, making the effective longest span equals 8'6" with 1/2" plywood sheathing. The new array (See Site map by contractor) will add 2,63 Lb. / Sf. overall to the roof The existing structure is sufficient to support the new loads associated with the additional weight & wind resistance. No additional structural support is required for the roof structure, 2. The attachment system shall be secured to the roof and shall be in strict compliance with manufacturers printed instructions. The attachment system shall be UL 1703 approved tested. Provide water tight sealant at all penetrations. Attachments shall follow panel rows as specified by the system manufacturer's installation manual. The panel angle shall match the roof slope. Reference summary table below: Roof Type: Shingle Fastener Max Spacing (in.) S�Ily "ROOFTECHW "RT MINI 11" & "UNIRAC SM" Mounting Systems Wind Zone I Wind Zone 2 Wind Zone 3 -Attachment Fastener Info: min. 5/16" x 4" long stainless -steel lags with a min. 48 24 24 embedment of 3" into the rafters 3. Solar Modules shall be UL- 1703 rated. Refer to manufacturers specifications sheets. 4. Positive drainage of the system shall be so as not to void the existing roof warranty. 5. All aspects of the installation shall comply with the Florida Administrative Code, 2020 Florida Building Code - Residential Seventh Edition, ASCE-7-16, 2020 Florida Building Code - Energy Conservation, Seventh Edition, 2017 National Electric Code, All Local Governing County and Municipal Ordinances adopted by reference or enacted by law. All components used meet the criteria of the Florida Solar Energy Center. 6. Please refer to the attached structural calculations. 0, If you have any questions relating to this matter, pl "OW Wqour earliest convenience. Thank you. C E Michael S. Rezk, P.E. VITA OF i 0 FL. Lic. No. PE95844 0 R I D .......... IONA L r-N //"///I 0\0\ Pro Custom Solar LLC 3096B Hamilton Blvd South Plainfield, NJ 07080 Gravity Load Calculation Criteria Structural Design Loads per ASCE 7-16 Dead Loads = 10 psf + 2.6 psf (new solar panels) = 12.6 psf Roof Live Load = 20 psf Ground Snow Load/Live Load = 0 psf Engineer -PE 732-902-6224 August 21, 2023 Wind Load Calculation Criteria Wind Loads per ASCE 7-16, Equation 29.4-7 Using an effective wind area of 10 SF, external pressure coefficient from Figure 30.3-A-1 Zone I = -36.5 psf Roof Slope = 23 degrees Roof Mean Height = 15 ft Zone 2 = -47.4 psf Basic Wind Speed = 140 mph Zone 3 = -54.7 psf Exposure = B Per section 2.4.1, ASD combo = D + 0. 6W: Zone I = 16 psf + 0.6(-36.5 psi) = -19.3 psf Zone 2 = 2.6 psf + 0.6(-47.4 psi} = -25.8 psf Zone 3 = 2.6 psf + 0.6(-54.7 psf) = -30.2 psf Check Attachment to Wood Truss Use 5/16 dia. Lag screw w/ 3" embedment into 2 in. wide roof rafter Lag Screw Spacing: Lag Screw Tributary Area: Zone I = 48" o.c. max Zone I = (48" o.c. maX)A 2 / 144 = 16 SF Zone 2 — 24" o.c. max Zone 2 = (24" o.c. maX)A2 / 144 = 4 SF Zone 3 = 24" o.c. max Zone 3 = (24" o.c, max)A 2 / 144 = 4 SF Lag Screw Forces: W = 266lb/in (Table 12.2A, 2015 NDS) Zone I = 193 psf x 16 SF = 309 lb < W', OK Cd = 1.6 (Table 2.3.2, 2015 NDS) Zone 2 = 25.8 psf x 4 SF = 103 lb < W', OK Ct = I (Table 2.3.3, 2015 NDS) Zone 3 = 30.2 psf x 4 SF = 121 lb < W', OK W'= W x embed x Cd x Ct W'= 266 lb/in x 3 in. xL6 x I = 1276.8 lb 3EPMEEL powered by OW''MANTUM D., PEAK "'DUO, H 60USSAR 128VSBAR CULTECHNOLOGY CELL TECHNOLOGY THE IDEAL SOLUTION FOR: 69 Rooftop arrays on residential buildings Quality Controlled PV FPPPPPP,L1, TOVRheirtland WWWAwcom to 1111232616 BREAMNG THE 20% EFFICIENCY BARRIER All, Q.ANTUM DUO Z Technology with zero gap cell layout boosts module efficiency up to 20.9 %. THE MOST THOROUGH TESTING PROGRAMME IN THE INDUSTRY Q CELLS is the first solar module manufacturer to pass the most comprehen- sive quality programme in the industry: The new "Quality Controlled PW of the independent certification institute TOV Rheinland. INNOVATIVE ALL-WEATHER TECHNOLOGY Optimal yields, whatever the weather with excellent low -light and temperature behavior. ENDURfNG HIGH PERFORMANCE Long-term yield security with Anti LID Technology, Anti RID Technology', Hot -Spot Protect and Traceable Quality Tra.QTM. EXTREME WEATHER RATING High-tech aluminum alloy frame, certified for high snow (5400 Pa) and wind loads (4000 Pa). A RELIABLE INVESTMENT E AW� Inclusive 25-year product warranty and 25-year linear performance warrant y2. I APT test conditions according to lEC/TS 62804-1.2015, method A (-1500V, 96h) 2 See data sheet on rear for further information. Engineered in Germany 0 CXARLS MECHANICAL SPECIFICNrION Fo"'r-at 74.0in x 41.1in x 1.26in (including frame) (1879mm x 1045mm x 32mm) Weight 48.5Ibs(22.Okg) Horst Covrsr O.13 in (3.2 min) thermally pre -stressed glass with anti -reflection technology � 3,;.<C.€lue= Composite film Frame Black anodized aluminum Coll 6 x 22 monocrystaliine Q.ANTUM solar half cells Junciion Box�-�_- 2.09-3.98in x 1.26-2.36in x 0.59-0.71in ^C,�abi _.n... (53-101mm x 32-60mm x 15-18mm), IP_67, with bypass diodes mcable;(+)=49.2in(1250mm),I-)>_49.2in(1250mm) 4mm2Solar �f7c nr r c,tcar� Staubli MC4; IP68 74.x Ile29mm) 42.In (1088 min) 492'(1250 4 x 6mvr�Nn9 cams a o.1a' (45mm) Lnbe ryx4-9.2-^ (1z6o min) 4. MOVn ,Hot¢ (DETAIL A) DETAIL A 0.63' (18 min) 0.96' (24.6 min) O T0.33' (a.5 min) ELECTRICAL CHARACTERISTICS 39.2' (996 min) 41.1't1045mm) POWER CLASS 385 390 396 400 405 MINIMUM PERFORMANCE A STANDARD TEST CONDITIONS, .£..�?POWERTOLERANCE:rfsilrt...OW) _.po"veaa,f INFIP, pn,Pn [W]._� 385 � 390 395 400� 405� Short Circuit Current,_��,......-....�...._. isr, vm....�.-.....[A] .�.�........._...�......1104 _....®. 11.07 11.10 11,14 .........,�.11.17 E O . rc u(t � nftagea - V, IV) 4519 _ 45.23 45.27 45.30 4534 m , _ _m �10.71 � � far rent at rt<?PP IMpp [A) 10.59 10,65 10.77 10.83 Vo€tage at L4FP VMpp [V] 36.36 36.62 36.88 37.13 37.39 ;wf6icdencv; ,_m...��._..� -tVIINIP,f(UNIP2ttrORNI,TNCEA1 .�.�...._. 9_.... I%I _...M._.._.... >_19.6 >_19.9 m � a20.1 z20.4 ...�.,._m__....,_..,>20.6 NOR`lt(AL OPERATING C.<rNDITIONS,NCq T, ..T..._._ r�krc:ratL , E _ PMpp (W) 2888 292.6.__._. 296.3 3001 � 303.$ Short 0rcua Curent isc �A] 8.90_ 8.92 8.95 8.97 � 9.00 Coen C,'C- , t . olt ag ' e _ taCurrent - - _ Vo IV] ._ 42,62 _ _ � 42.65 _8.41 42.69 _ 42.72 42.76 at h1 P F pv [A] 8,35 8.46 8.51 8.57 va,eu5e at M'PM VMpn [V] 3459 34.81 � 3503 35.25 35.46� 'Measurement tolerances PM f3 %; Is, V,c+S % at STC 1000 W/m2, 25±2°C, AM 15 according to IEC 60904-3. 2800 W/m2 NMOT, spectrum AM 1.5 0 CELLS PERFORMANCE WARRANTY PERFORMANCE AT LOW IRRADIANCE III TARS At least 98% of nominal power during no first year. Thereafter max. 0.5 % degradation per year. At least 93.5 % of nominal power up to 10 years_ At least 86% of nominal power up to 25years. 4 %o--r-----r-----r-----r-----, I I i i All data within measurement toleranc- es. Full warranties in accordance with 200 400 Soo W 1000 the warranty terms of the Q CELLS ,RfRAMANCF iW11 1 sales organisation of your respective country. Typical module performance under low Irradiance conditions in comparison to STC conditions (25 °C,1000 W/m2) TEMPERATURE COEFFICIENTS esrpe_, asxr e Coefficient of Es. a [/ lK] +0 04 Tee) e sturts Coefficient of VI ,, R [%/K] 0 27 n;p t rfaUrt) C.(t: IMer) of M � y (%/K] - -0 34 Stamina! M<owle Opera6nq Temperature NMOT ['F[ � 109+5.4 (43±3°C) PROPERTIES FOR SYSTEM DESIGN [V] 10Q0 (IEC)/1000 (UL) V ax) _ i Sy=a n Voltage „-.4 P V in€adule classification � � Class II lalaxm,um Series Fuse Rating [A DC) .-.....-.�......._... 20 -" Fire gating ba e. d on ANSI UL 61730 ._.,......,_...,_ TYPE 2 ?GI?x,DesignLo„1, Push I F't.tlt.s fibs/W] 75(3600 Pa)/ 55(2660 Pa)� Peri-nitted Module letup,r;atutem.�.�....�._..�,�.�.m.�~ ...._.m�m.�..�.m. -40°F up to+185°F Sfax, Test Load, d =`P Ea � ry [Ibs/ft2]-113(5400Pa)/84(4000Pa) on ___„flnuousDuty (-40°Cupto+85°C) 'See Installation Manual....�...�.._.�..,..,,�.�...._..�.._..ma...,�,.._.____x.._._...,�....�_.__,_,_ QUALIFICNrIONS AND CERTIFICATES PACKAGING INFORMATION UL 61730 CE- nniel am, 1 53' Quality Controlled PV TUV Rheinland, iD a-Q 40 HC IEC 61215:2016, IEC 617302016, /► ]--s�- ---------•-�- ----n---------- US,PatearNo 9,893,215(3oiarcelie, �r Tway ) Horizontal 76.4in 433in 48.Oin 1656lbs 24 24 32� packsgin3 1940mm 1100mm 1220mm 751kg pallets pallets modules C amraeUS ♦ u161730 ID 1111320277 Note: Installation instructions must be followed. See the installation and operating manual or contact our technical service department for further information on approved installation and use of this product Hanwha Q CELLS America Inc. 400 Spectrum Center Drive, Suite 1400, Irvine, CA 92618, USA I TEL +1949 748 59 961 EMAL inquiry@us.q-celis.com I WEB www.q-cells.us Rt'W,1J-VVXtK*%7TT 2eff -to 4_1 is our proprietary application -specific integrated circuit (ASIC) which enables the x0cr#iAv9rt9r ts, #,#-erzte *r#X-1jrif xx*09s. TXis oXiA, is �jvilt i-.k 74v?.Ace-4 55nm technology with high speed digital logic and has super -fast response times energy systems. Part of the Enphase Energy System, 108 Series IQ8 Series Microinverters redefine reliability Microinverters integrate with the Enphase 10 Battery, standards with more than one million cumulative Enphase IQ Gateway, and the Enphase App monitoring hours of power -on testing, enabling an industry - and analysis software. leading limited warranty of up to 25 years. Connect PV modules quickly and easily to IQ8 Series IQ8 Series Microinverters are UL Listed as Microinverters using the included Q-DCC-2 adapter PV Rapid Shut Down Equipment and conform with cable with plug-n-play IVIC4 connectors. various regulations, when installed according to manufacturer's instructions. 0 2022 Enphase Energy, All rights reserved. Enphase, the Enphase logo, 108 Microinverters, and other names are trademarks of Enphase Energy, Inc. Data subject to change. Lightweight and compact with plug-n-play connectors Power Line Communication (PLC) between components Faster Installation with simple two -wire cabling , - T47Wr1ffMM-AVR7 Produce power even when the grid Is down* More than one million cumulative hours • testing • powered PV modules Microgrid-forming Complies with the latest advanced grid Support" Remote automatic updates for the latest grid requirements Configurable to support a wide range of grid profiles Meets CA • 21 (UL 1741-SA) requirements Only when installed with 10 System Controller 2, meets UL 1741.108H-208V operates only In grid -tied mode. IQ8 Series Microinverters supports split phase, 240V. IQ8H-208 supports split phase, 208V only. 11 11 111,, 1 1 1 1 1111 INN 11111111 11 MIN Commonly used module pairings' W 235-350 235-440 260-460 295-500 320-540+ 2951500+ Module compatibility 60-cell/120 half -cell 60-cell/120 half -cell, 66-cell/132 half -cell and 72-cell/144 half -cell MPPT voltage range v 27-37 29-45 33-45 36-45 38-45 38-45 Operating range V 25-48 25-58 Min/max start voltage v 30/48 30/58 Max input DC voltage V 50 60 Max DC current3 (module Isc] A 15 Overvoltage class DC port It DC port backfeed current mA 0 PV array configuration 1xI Ungrounded array; No additional DC side protection required; AC side protection requires max 20A per branch circuit Peak output power VA 245 300 330 366 384 366 Max continuous output power VA 240 290 325 349 380 360 Nominal (L-L) voltage/range4 v 240 / 211- 264 208 /183 - 250 Max continuous output current A 1.0 1.21 1.35 1.45 1.58 1.73 Nominal frequency Hz 60 Extended frequency range Hz 50-68 AC short circuit fault current over 2 4.4 3 cycles Arms Max units per 20 A (L-L) branch circuits 16 13 11 11 10 9 Total harmonic distortion <5% Overvoltage class AC port III AC port backfeed current mA 30 Power factor setting 1.0 Grid -tied power factor (adjustable) 0.85 leading - 0,85 lagging Peak efficiency % 97.5 97.6 97.6 97.6 97.6 97.4 CEC weighted efficiency % 97 97 97 97.5 97 97 Night-time power consumption mw 60 Ambient temperature range -400C to +60°C (-40°F to +140°F) Relative humidity range 4% to 100% (condensing) DC Connector type MC4 Dimensions (HxWxD) 212 mm (8.3") x 175 mm (6.9") x 30.2 mm (1.2") Weight 1.08 kg (2-38 lbs) Cooling Natural convection - no fans Approved for wet locations Yes Pollution degree PD3 Enclosure Class 11 double -insulated, corrosion resistant polymeric enclosure Environ. category / UV exposure rating NEMA Type 6 / outdoor CA Rule 21 (UL 1741-SA), UL 62109-1, UL1741/IEEE1547, FCC Part 15 Class B, ICES-0003 Class B, CAN/CSA-C22.2 NO. 107.1-01 Certifications This product is UL Listed as PV Rapid Shut Down Equipment and conforms with NEC 2014, NEC 2017, and NEC 2020 section 690.12 and C22.1-2018 Rule 64-218 Rapid Shutdown of PV Systems, for AC and DC conductors, when Installed according to manufacturer's instructions. (1) The IQ8H-208 variant will be operating in grid -tied mode only at 208V AC. (2) No enforced DC/AC ratio. See the compatibility calculator at https://Iink.enphase,com/module-compatibility (3) Maximum continuous input DC current is 10.6A (4) Nominal voltage range can be extended beyond nominal if required by the utility. (5) Limits may vary. Refer to local requirements to define the number of microinverters per branch in your area. IQ8SE-DS-0001-01-EN-US-2022-03-17 I 11 is suitablefor all systems with a conventional V x 1" Carriage Bolt EMT RT Serrated 1 " On i LI! IAI Components ,a Optional Items: I Al— - Mi. - RT-Butyl is RnoJTech'a flexible flashing used in one million residential PVsystems for the last 27years, |tisthe first PVmounting system with Flexible Flashing certified by the |CC. Engineered to withstand wind speeds up0m18Omph and ground snow uptuBOpot PEStamped Letters available stvmxm.noof-tech.uv/support Dimensions in 10 � � � �0) � � ROOF TRUSSES SPAN 'L' it 14 li 11 Ii li li 1! ti II If 4i i! II it ii II (I ii II ii II tt II RI I1 11 1t -f i--1 iT - - - -fii- - - - - - - I11 I - -fit Tr- C It I l i A l A I I IG I I I I I I --{,j}$j�,- -i6( t 4 i 4�P 4 t i t i 4 d-i- -� { F Iit t I f `u I I I! 1 1 1 t l it I t7 _._...-._._..... _ _ Yf-_____.e.__`nT...... T'r it t If II III t1 it it 11 i t I 1 1 I I d l i i t I t t t I I 1I I YY' If � ttl if .11, I I i l i i V fi I i i I I l l I f Ii t I1 II GI ti ii if II II 1- II :il iil` : -II 11 11 fF C II i II li i;l ii ii II II I ii I it It !!I I7 11 It 7 ft I if ti Iti It it li 41 1 1 i F I 4 f I F E I EEFFii##tt yI I +i Ir It it u u it It i �... i 1 �/ 1 � I{ '� t i i I RT-MINI IIJ I AN:=A,PE MODU FS PLAN VIEW NOTE: OVERHANG AS PER PANEL MANUFACTURER'S INSTRUCTIONS. SHOULD BE EQUAL ON BOTH SIDES OF PANELS. DESIGN LOAD CAPACITY - PSF (LANDSCAPE MODULES) UP TO 80" PANEL LENGTHS NUMBER OF RAILS SPAN 'L' FLAT ROOFS ROOF SLOPES UP TO r ROOF SLOPES 8" TO 20' ROOF SLOPES 21' TO 27" ROOF SLOPES 88' TO 45" ANCHOR TYPE 'A' ANCHOR TYPE ANCHOR ANCHOR TYPE '8' ANCHOR TYPE 'A' ANCHOR TYPE '8' ANCHOR ANCHOR TYPE 'A' TYPE 'B' ANCHOR TYPE 'A' ANCHOR TYPE 'B' 16" 230.3 247.8 229.6 247.2 228.2 245.8 227.3 245.0 225.2 243.0 24' 154.9 166.6 154.2 16.5.9 152.7 164.5 151.9 163.8 149.7 161J 32" 117.2 125.9 116.5 I f 25.3 115.0 123.9 114.2 123.1 112.0 121.1 2 - 46" 79.4 85.3 78.7 84.6 77.3 83.3 76.5 82.5 74.3 80.4 64" 60.6 65.0 59.9 64.3 58.4 62.9 57.6 62.2 55.4 60.1 72" 54.3 58.2 53.6 57.5 52.1 56.2 51.3 55.4 49.1 1 3.3 16' 250.0 250.0 250.0 250.0 250.0 250.0 250.0 250.0 250.0 250.0 24" 209.3 225.2 208.6 224.5 207-1 223.1 206.3 222.4 204.1 220.3 _ _ 32" 158.0 169.9 157.3 169.2 155.8 16T9 155.0 167A 152.8 165.0 3 _ 48" 106.6 114.6 105.9 113.9 104.5 112.6 103.7 111.8 101.5 109.7 64" 81.67 86.9 80.3 86.3 78.8 84.9 78.0 84.9 75.8 82.1 72" 72.4 1 77.7 1 71.7 1 77.1 70.3 75.7 69.4 _74.9 ._ 67.3 72.9 LOADS SHOWN IN CHARTS ABOVE ARE FOR PANEL WIDTHS UP TO 40" FOR WIDER PANEL WIDTHS (41" TO 48"), DETERMINE DESIGN LOADS AS FOLLOWS DESIGN LOAD Q LOAD FROM CHART X 40 NEW PANEL WIDTH q/� Z�n V Z g 0 �' a PV RAILS V t a pm 22 OR 3 PER PANEL Q= EQUALLY SPACED ^r 0 m SEE CHART BELOW 0 i1 t0 O .+ 0MOc Q W = IL z Dro ° o ,yyp/ M �4 W 0 f W RT-MINI II ROOF TOP PV MOUNTING SYSTEM cD THIS PRODUCT HAS BEEN DESIGNED AND TESTED TO COMPLY WITH THE Z a REQUIREMENTS OF THE 2020 (7TH EDITION) FLORIDA BUILDING CODE _ IN INCLUDING HIGH VELOCITY HURRICANE ZONE (HVHZ). O ,➢ o m w THIS PRODUCT APPROVAL IS FOR THE ROOF TOP PV MOUNTING SYSTEM AS SHOWN ON THESE APPROVED DRAWINGS. a ROOF DETAILS, UPLIFT, SLOPE, ROOF TRUSSES AND OTHER ELEMENTS n. m SHALL BE DESIGNED BY A FLORIDA REGISTERED ENGINEER AND REVIEWED O 1- ci N BY THE STRUCTURAL PLANS EXAMINER OF THE CORRESPONDING BUILDING DEPARTMENT. f CONDITIONS NOT SHOWN IN THIS DRAWING ARE TO BE ANALYZED SEPARATELY, o AND TO BE REVIEWED BY BUILDING OFFICIAL. O INSTALLATION OF PV PANEL ACCESSORIES SHALL BE DONE IN ACCORDANCE - B- ~ DO w WITH THE CURRENT EDITION OF FLORIDA BUILDING CODE AND THE MANUFACTURER'S INSTALLATION INSTRUCTIONS. g O ANCHORS SHALL BE CORROSION RESISTANT, SPACED AS SHOWN ON DETAILS AND INSTALLED PER MANUF'S INSTRUCTIONS. SPECIFIED EMBEDMENT TO BASE �- MATERIAL SHALL BE BEYOND ROOF COVERING. I I DESIGN LOADS SHOWN ARE BASED ON 'ALLOWABLE STRESS DESIGN (ASD)°. E SOLAR PANELS TO BE INSTALLED PARALLEL TO THE ROOF SURFACE WITH A TOLERANCE OF 2 DEGREES. PV PANELS NOT PART OF THIS APPROVAL. FOR PANEL DETAILS, GENERAL NOTES, COMPONENT SIZES, PANEL RAIL CONNECTION TO RT-MINI It AND INSTALLATION REOUIREMENTS/LIMITATIONS SEE CORRESPONDING FLA. APPROVAL DWGS. A- CONTRACTOR TO BE RESPONSBLE FOR THE SELECTION, PURCHASE AND INSTALLATION OF THIS PRODUCT BASED ON THIS PRODUCT EVALUATION PROVIDED HE/SHE DOES NOT DEVMTE FROM THE CONDITIONS DETNLED ON THIS DOCUMENT. B-THIS PRODUCT EVN.UATION DOCUMENT WILL BE CONSIDERED INV%ID IF ALTERED BY ANY MEANS. C- SffE SPECIFC PROJECTS SHALL BE PREPARED BY A FLORIDA REGISTERED ENGINEER OR ARCHITECT W H WILL BECOME THE ENGINEER DF RECORD (EO.R.) FOR THE PROJECT AND WHO WILL BE RESPONSIBLE FOR THE PROPER USE OF THE P.E.D. ENGINEER OF RECORD, ACTING AS A DELEGATED ENGINEER TO THE P.E.D. ENGINEER SHALL SUBFAT TO THIS LATTER THE SITE SPECIFIC DRAWINGS FOR REVEAL D-THIS P.E.D. SHALL BEAR THE DATE MO ORIGINAL SEAL AND SIGNATURE OF THE PROFESSIONAL ENGRtEER OF RECORD THAT PREPARED 9. 4/20/2021 FL #38617 'S. . `\ a PBa.61223 o w =-0 ' 8T =� ; drove ng ` no. 21-27F SPAN 'L' (BETWEEN SUPPORTS) . SPAN V 12013'Rul 0711#101114V DESIGN LOAD CAPACITY - PSF (PORTRAIT MODULES) UP TO 68" PANEL LENGTHS NUMBER OF PAILS SPAN V FLAT ROOFS ROOF SLOPES UP TO 7' ROOF SLOPES a, TO 20, ROOF SLOPES 21' TO 27' ROOF SLOPES 28* TO 45' ANCHOR ANCHOR r ANCHOR TYPE *A` ANCHOR TYPE 'S' ANCHOR ANCHORANCHOR TYPE 'A' TYPE 'V ANCHOR ANCHOR 16" " 137.1 147.4 136.4 146.8 135.0 145.4 1 6 24' 92.8 99.6 92.0 99.0 90.6 97.6 32' 70.6 75.7 69.9 75A 68.4 7ZL7 67.6 72.9 48' r64' 48.4 51.8 47.7 51.1 46.2 49.8 45.4 49.0 43.2 47.0 3733 39.9 36.6 39.2 351 37.8 34.3 37.1 32.1 35.0 72, 33.6 35.9 32.9 35�2 31:4 33.8 30A 33.1 28.4 310 16- 175.5 188.7 174.8 188.1 173.3 186.7 172.5 185.9 170.3 183.9 24- 118.3 127.2 117,6 126.5, 116A 125.1 115.3 124 - .3 111.2 122.3 1. 89.7 96.4 69-0 95.7 87.6 94.3 86.7 93.6 84.6 91.5 61.2 65.6 604 64.9 59.0 63.6 58.2 62.8 -48' 64" 46.9 50.2 40. 2 [::1 49.5 �44.4 447 44.7 48-2 43-9 47 45 4p# . , .5., 41.4_ 4� 43-0 1 39.1 42.2 36.9 40,2 LOADS SHOWN IN CHARTS ABOVE ARE FOR PANEL LENGTHS UP TO 68" FOR SHORTER PANEL LENGHTS. DETERMINE DESIGN LOADS AS FOLLOWS LOAD FROM CHART X 68 DESIGN LOAD = NEW PANEL LENGTH NOTE: z 0 OVERHANG AS PER PANEL MANUFACTURER'S INSTRUCTIONS. SHOULD BE EQUAL ON BOTH SIDES OF PANELS. OEM It Rg- o tgpm 0 � -.4 of . PV RAILS o 0 4 2 OR 3 PER PANEL -EQUALLY SPACED m mn IN SEE CHART BELOW z1f .8 DESIGN LOAD CAPACITY - PSF (PORTRAIT MODULES) UP TO 80" PANEL LENGTHS NUMBER� OF RAILS SPAN I: FIAT ROOFS ROOF SLOPES UP TO 7' ROOF SLOPES 8' TO 20* ID ES ROOF SLOPES 0 F� 21* TO 27* D ROOF SLOPES 28* TO 45* =41� ANCHOR PE ANCHOR TYPE 'A' ANCHOR TYPE 'S' 'A' 7 ANCHOR E `8 TYPE 'A' SYPE S, ANCHOR TYPE 'k ANCHOR TYPE 'a' 16' 117.2 125.9 116.5 125.3 S 0 � 123.9 �-2 tll 1124 121.1 24� 79.4 8531 78.7 84.6 717.�3 83.3 7�5 �*�;3 80.4 _2_ 32" 60.6 65.0 59.9 64.3 4 62 .9 57.6 62.2 6011 2 48' - Z.7 I 44.6 ---- 41.0 44.0 39.6 42.6 38.7 . I 41.6 36.6 39.8 64" 32.3 34.5 31.6 310 30.1 32.5 29.3 31.7 27-1 t ZV6 72' 29.1 31.1 28.4 30A 27.0 29.1 26.2 28.3 24.0 26�2 16' 134,11 144.1 133.4 143.5 131.9 142.1 131.1 141.3 128.9 139.3 90.7 97.4 90.0 96.8 88.6 95.4 87.7 94-6 1 85.6 92.6 69.0 74.1 68.3 73.4 66,9 72.0 66.0 71.3 63-9 69.2 503 46.5 50,0 45.2 48.7 "A 47.9 421 45-9 _47.4 36.5 39-0 35.8 38A 34.4 37.0 33-5 36.2 31.4 34.2 3279 1 3Z2 34.5 30,7 33.1 29.9 32.3 27.8 303 LOADS SHOWN IN CHARTS ABOVE ARE FOR PANEL LENGTHS UP TO 80" FOR SHORTER PANEL UENGHTS (68- TO 80-), DETERMINE DESIGN LOADS AS FOLLOWS DESIGN LOAD LOAD FROM CHART X 80 - NEW PANEL LENGTH �i F� NcL 81223 STA g no. 2 -27F EQ. ED. r RAIL CENTERLINE ALLOWABLE ZONE MIDDLE 2.5' 3/8- 1 3/16-± (30MM)_/ 1 3/16-± (30MM) (NO BOLT ZONE) (NO BOLT ZONE) 2' MIN. t 9/16-± (40MM) — (ALLOWABLE BOLT ZONE) 3/16-± (WMM)_/ (NO BOLT ZONE) 1 9/16-± (40MM) (ALLOWABLE BOLT ZONE) Lu- RAIL CENTERLINE .591 ALLOWABLE ZONE P MIDDLE 2.5* O 3,937 'J56 L 1 3/16-* (30MM) - I' MIN (NO BOLT ZONE) -1.969 2' tMIN, .614 D90 3.543 -- ---------------------------- PV MODULE NOT PART OF THIS APPROVAL __-______-- PV MODULE RAIL NOT PART OF THIS APPROVAL --2 T-- 5/16- DLk HE� BOLT PiL-FOOT OR EMC i p /-NOT PART OF THIS APPROVAL ---- --------- PLYWOOD SHEATHING r-15/32- MAX. FOR FASTENER TYPE :A' 9/32- MAX. FOR FASTENER TYPE B' I f 9� \\\-BUTYL TAPE 1 2 FLASHING/SPACER cv MINI 11 FASTENERS (2) PER BRACKET r BY 5ECTIOb! A-6 RT—MINI 11 FASTENERS: (AT ROOF TRUSSES) TYPE W- M5 X 60mm SS304 SELF -DRILLING SCREWS (MAX. ALLOW. TENSION = 569 lbf, MAX. ALLOW. SHEAR - 404 bf) TYPE *8'- MS X 90mm SS304 SELF -DRILLING SCREWS (MAX. ALLOW, TENSION = 613 lbf, MAX. ALLOW. SHEAR = 470 tbf) CENTERED AT WOOD TRUSSES (SG = 0.50 MIN.) RI-Mitil I 6063-TS ALTERNATE ORIENTATION rl� Z 0 aN 0 cy10j. 8 0 04 oet z zOmE-1l W z I= 0 zCV 0 0. V) V) 0 z c L) 4D C; F-t m z 2 I 0 ow C V) ON SHEETS I & 2 4/20/2021 No. 81223 V o" no. FL #38617 3 �-f 3 RAIL STRONGHOLD ATTACAMERT KIT SEE PAGE NH-P01 SEE PAGE NH-A04 PHONE: 505.242.6411 WWW.UNIRAC.COM PRODUCT LINE: NXT HORIZOII DRAWING TYPIII I III E: PART & ASSEMBLY MODULE ASSEMBLY� 'DESCRIPTION: REVISIONI IIII� MI DATE:i 9/30/2021 i L- DRAWING NOT TO SCALE ALL DIMENSIONS ARE NOMINAL LEGAL NOTICE RAIL & CLAMP CAP KIT SEE PAGE NH-A09 s "UNIRAC on on PHONE: 505.242.6411 WWW.UNIRAC.COM PRODUCT LINE: NXT HORIZON DRAWING TYPE: PART & ASSEMBLY 1 DESCRIPTION: M*VULE ASSEMBLY I., 1:94tivi, &011 col 9/30/2021 016114M: W98 DRAWING NOT TO SCALE ALL DIMENSIONS ARE NOMINAL LEGAL NOTICE -PART # TABLE DESCRIPTION 014FTILWOM NXT HORIZON COMBO CLAMP - MILL HORIZON COMBO CLAMP - DARK I i 30MM TO 40MM MODULE FRAME a - W., No i W, � Impwifilqu, 6 113m., PHONE: 505.242.6411 WWW.UNIRAC.COM is PRODUCT LINE: NXT HORIZON DRAWING TYPE: PART is ASSEMBLY DESCRIPTION: COMBO CLAMP Rblavjs'.4(61.10=� 9/30/2021 DRAWING NOT TO SCALE LE ALL DIMENSIONS ARE NOMINAL y 1ODD6 PROTECTED Bly), 4TS ONE OR MORE US PATENTS! LEGAL NOTICE PART # TABLE DESCRIPTION STRONGHOLD ATT IT COMP MILL STRONGHOLD ATT KIT COMP DRK SHCPKTM1-NS STRONGHOLD ATT COMP MILL (NS) SHCPKTD1-NS STRONGHOLD ATT COMP DRK 33/811 PHONE: 505.242.6411 WWW.UNIRAC.COM MN 0 ; 6MAINWA114019 I 5/16" x 4" SS LAG BOLT fflmmmoffl� IVI }»f+y 2}#�■�� 6��� #� #��} DESCRIPTIO Ilk DRAWING NOT TO SCALE ALL DIMENSIONS ARE NOMINAL Fr' PRODUCT PROTECTED BY I WTI= PART # TABLE DESCRIPTION * III QlVZ='STkONGHOLD RAIL CLAMP MILL "I'll", 0 m sloff"TT'llitalwMal i ""UNIRAC ne an ,00"AlmiN, m- PHONE: 505.242.6411 WWW.UNIRAC.COM 2" A A III DESCRIPTION: 5/16"-18 x 2" SERRATED FLANGE HEX SCREW DRAWING NOT TO SCALE ALL DIMENSIONS ARE NOMINAL PRODUCT PROTEII III CTED IIIIIII III B ONE OR MORE US PATE 5 LEGAL NOTICE PART # TABLE DESCRIPTION E1111CM11:14NXT HORIZON MLPE & LUG CLAMP o's" a U N I RAC 011111111"W" My 01 MR PHONE: 505.242.6411 WWW.UNIRAC.COM clillcil 10 — III PRODUCT LINE: NXT HORIZON DRAWING TYPE: PARTS ASSEMBLY DESCRIPTION: M LPE & LUG CLAMP DRAWING NOT TO SCALE ALL DIMENSIONS ARE NOMINAL PRODUCT GIs OTECTE B 0 uOR MORE US PATENTS, TS LEGAL NOTICE PART # TABLE DEST CRIPTION MUNISM001=1 N HORIZON NS WIRE MGM-T-CLIP w, 8 O'so"UNIRAC a INN" limpmatill*oz Ewe PHONE: 505242.6411 WWW.UNIRAC.COM EN RgA , fVrITO Ap�� "I ,jUal-qjU 014*00,4121 WivaLlizzmadLoill! DRAWING NOT TO SCALE ALL DIMENSIONS ARE NOMINAL LEGAL NOTICE mass U N I RAC a PHONE: 505.242.6411 WWW.UNIRAC.COM PART # TABLE DESCRIPTION NXT HORIZON WIRE MGMT CLIP ll�� 6- U-C- ­T L---I-N-E:---,i, HORIZO N^ } DRAWING TYPE DESCRIPTION: WIRE MGMT CLIP ;REVISION DATE: 10/27/2*21 0 N-. DRAWING NOT TO SCALE ALL DIMENSIONS ARE NOMINAL 0:40 * It's LEGAL NOTICE PART # TABLE DESCRIPTION M:Ikllblo—,Igpm--NXT HORIZON RL & CLMP CAP KIT mm Y16" FIF11 PRODUCT LINE: III III NXT HORIZON DRAWING NOT TO SCALE ALL DIMENSIONS ARE DRAWING TYPE: •Ar Ili. OMINAL RAIL & CLAMP CAP PRODUCT PROTECTED B it DESCRIPTION: LEGAL NOTICE PART # TABLE DESCRIPTION Go mm. NXT HORIZON \4� " MILL \ / \ \. NXT HORIZON RAIL 84" DARK \\ \ \\ \ NXT HORIZON RAIL 168" MILL \ \ \ \ / / of-M-11.441-031 . NXT HORIZON RAIL 168" DARK .\ �tvlol� lP%Illo*Jj4jkj NXT HORIZON RAIL 208" MILL \\ \\ \ \\\ \.\f I ON RAI/\: \ . .\ : t\\� i2*111.1*1ANU NXT HORIZON RAIL 246" MILL \. \ f \ \\NXT HORIZON /AI\.\\\\ DARK \ \\ /\ \ \\. m "UNIRAC illm all PHONE: 505.242.6411 WWW.UNIRAC.COM PRODUCT LINE: 'I I 11 NXT HORIZON 1 DRAWING TYPE:, PART DETAIL DESCRIPTION: A \|� � } L11,14"T I I Voill, I#\ } 9ffiE U111717.111TITI %'719-OTTIF-SUM ALL DIMENSIONS ARE NOMINAL m'"'A I " lill 0 LEGAL NOTICE A TABLE DESCRIPTION MUM; NXT HORIZON RAIL SPLICE I R "UNIRAC on as PHONE: 01,111 NUNN, ! 56411 WWW.UNIRAC.COM I � PR II T INE: I HORIZONII NXT �DRAWINGTYPE: ! DETAIL I �0412110101 M �I; IIL SPLICE REVISION DATE: 9/22/2021 A 11 ALE DRAWING LE .. ,. 1 A1 ► ARE DIMENSIONS NOMINAL M i 0 0 a VI i t In I@f➢�IMII 41 11 iY. 0 M .. LEGAL NOTICE Enphase Networking Enphase IQ Combiner 3 LISTED To learn more about Enphase offerings, visit enphase.com The Enphase IQ Combiner 3'" with Enphase IQ Envoy"' consolidates interconnection equipment into a single enclosure and streamlines PV and storage installations by providing a consistent, pre -wired solution for residential applications. It offers up to four 2-pole input circuits and Eaton BR series busbar assembly. REM Includes IQ Envoy for communication and control • Flexible networking supports Wi-Fi, Ethernet, or cellular Optional AC receptacle available for PLC bridge • Provides production metering and optional consumption monitoring IMM Reduced size from previous combiner Centered mounting brackets support single stud mounting Supports back and side conduit entry Up to four 2-pole branch circuits for 240 VAC plug-in breakers (not included) 80 A total PV or storage branch circuits Durable NRTL-certifiedNEMA type 3R enclosure Five-year warranty UL listed i I ii C I 1111IN1101 11 � ra oxg ACCESSORIES and REPLACEMENT PARTS (not included, order separately) Consumption Monitoring* CT CT-200-SPLIT Split core current transformers enable whole home consumption metering (+/- 2.5%). EPLC-01 Power line carrier (communication bridge pair), quantity 2 XA-PLUG-120-3i Accessory receptacle for Power Line Carrier in 10 Combiner 3 (required for EPLC-01) XA-ENV-PCBA-3 Replacement IQ Envoy printed circuit board (PCB) for Combiner 3 ELECTRICAL SPECIFICATIONS Rating Continuous duty System voltage 120/240 VAC, 60 Hz Eaton BR series busbar rating 125 A Max. continuous current rating (output to grid) 65A Max, fuse/circuit rating (output) 90A Branch circuits (solar and/or storage) Up to four 2-pole Eaton BR series Distributed Generation (DG) breakers only (not included) Max. continuous current rating (input from PV) 64 A Max. total branch circuit breaker rating (input) BOA of distributed generation / 90A with IQ Envoy breaker included Dimensions (WxHxD) 49.5 x 37.5 x 16.8 cm(19.5' x 14.75x 6.63"). Height is 211:06" (53.5 cm with mounting brackets). Weight 75 kg (16.5 lbs) Ambient temperature range -400 C to +460 C (400 to 1150 F) Cooling Natural convection, plus heat shield Enclosure environmental rating Outdoor, NRTL-certified, NEMA type 3R, polycarbonate construction Wire sizes 20 A to 50 A breaker inputs: 14 to 4 AWG copper conductors 60 A breaker branch input: 4 to 1/0 AWG copper conductors Main lug combined output: 10 to 2/0 AWG copper conductors Neutral and ground: 14to 1/0 copper conductors Always follow local code requirements for conductor sizing. Attitude To 2000 meters (6,560 feet) INTERNET CONNECTION OPTIONS Integrated WI-Fi 802.11b/g/n Optional, 802.3, Cat5E (or Cat 6) UTP Ethernet cable (not included) Compliance, IQ Envoy UL 60601-1/CANCSA 22.2 No. 61010-1 * Consumption monitoring is required for Enphase Storage Systems. 'c) 2018 Entahase Energy. All rights reserved. All trademarks or brands in this document are registered by their respective owner 2018-09-13