HomeMy WebLinkAbout23-6985IAddress: 37340 Picketts Mill Ave
ZEPHYRHILLS, FL 33542
191,IMA-
INSTALLATION ROOF MOUNT PV SOLAR
Electrical Permit Fee
City of Zephyrhills
5335 Eighth Street
Zephyrhills, FL 33542 ELCMISC-006985-2023
Phone: (813) 780-0020 Fax: (813) 780-0021 Issue Date: 09/29/2023
• F-Tn- HUM111111
Building Valuation: $0.00
Electrical Valuation: $45,851.50
Mechanical Valuation:
Plumbing Valuation:
Total Valuation: $45,851.50
Total Fees: $269.26
Amount Paid: $269.26
Date Paid: 9/29/2023 2:01:51PM
REINSPECTION FEES: (c) With respect to Reinspection fees will comply with Florida Statute 553.80(2)(c) the
local government shall impose a fee of four times the amount of the fee imposed for the initial inspection or
first reinspection, whichever is greater, for each subsequent reinspection.
Notice: In addition to the requirements of this permit, there may be additional restrictions applicable to this property that
may be found in the public records of this county, and there may be additional permit required from other governmental
entities such as water management, state agencies or federal agencies.
1 11 11 � I mn• • •mmEn= I M-11==
Complete Plans, Specifications add fee Must Accompany Application. All work shall be performed in
accordance with City Codes and Ordinances. NO OCCUPANCY BEFORE C.O.
NO OCCUPANCY BEFORE C.O.
CONTRACTOR SIGNATURE PE IT OFFICE[)
'.EERMIT EXPIRES IN 6 MONTHS WITHOUT APPROVED INSPECTIOK
CALL FOR INSPECTION - 8 HOUR NOTICE REQUIRED
PROTECT CARD FROM WEATHER
813-780-0020 City of Zephyrhills Permit Application Fax-813-780-0021
Building Department
Date Received 813 695 9203
Phone Contact for Permittin —
tl8atte€[ i
Owner's Name Craig T & Alison Boisseau Owner Phone Number 407-595-3015
owners address 1 37340 Picketts Mill Ave Zephyrhills FL 33542 Owner Phone Number
Fee Simple Titleholder Name Owner Phone Number
Fee Simple Titleholder Address
JOB ADDRESS 37340 Picketts Mill Ave Zephyrhills FL 33542 LOT# 62
SUBDIVISION SILVER OAKS VILLAGE -PHASE ONE
WORK PROPOSED B NEW CONSTR
xx 8
INSTALL
PARCEL ID# 03-26-21-0200-00000-0620
(OBTAINED FROM PROPERTY TAX NOTICE)
ADD/ALT = SIGN DEMOLISH
REPAIR
PROPOSED USE
SFR 0 COMM OTHER
TYPE OF CONSTRUCTION
BLOCK FRAME STEEL 0
DESCRIPTION OF WORK
Install roof mounted solar PV system
BUILDING SIZE
SO FOOTAGE
HEIGHT
UILDING
$ 45851.50
VALUATION OF TOTAL CONSTRUCTION
I�LECTRICAL
$ avow AMP SERVICE
❑
PROGRESS ENERGY
❑
W.R.E.C.
OPLUMBING
DECHANICAL $
❑GAS ROOFING
FINISHED FLOOR ELEVATIONS
VALUATION OF MECHANICAL INSTALLATION
SPECIALTY = OTHER
FLOOD ZONE AREA =YES NO
BUILDER COMPANY Sunbility
;SIGNATURE L REGISTERED ./ Y / N FEE CURREN I Y / N �
Address 1103 90th St. Tampa, FL 33619 v License # EC 13008424
ELECTRICIAN COMPANY Sunbility ----
SIGNATURE REGISTERED ✓ Y / N FEE CURREN I Y / N
Address 1103 90th St. Tampa, FL 33619 License # I EC13008424
PLUMBER COMPANY
SIGNATURE ( REGISTERED Y % N FEE CURREN Y ( N
Address License #
MECHANICAL I COMPANY
SIGNATURE REGISTERED YIN FEE CURREN _YIN
Address License #
OTHER COMPANY
SIGNATURE REGISTERED Y / N FEE CURREN Y / N
Address License #
eE#etllltllt![tIIEFtiEi[t#aeHEBt#eaeBEaaeeHaieeelealtlttesla
RESIDENTIAL Attach (2) Plot Plans; (2) sets of Building Plans; (1) set of Energy Forms; R-O-W Permit for new construction,
Minimum ten (10) working days after submittal date. Required onsite, Construction Plans, Stormwater Plans wt Sift Fence installed,
Sanitary Facilities & 1 dumpster; Site Work Permit for subdivisions/large projects
COMMERCIAL Attach (2) complete sets of Building Plans plus a Life Safety Page; (1) set of Energy Forms. R-O-W Permit for new construction.
Minimum ten (10) working days after submittal date. Required onsite, Construction Plans, Stormwater Plans w/ Silt Fence installed,
Sanitary Facilities & 1 dumpster. Site Work Permit for all new projects. All commercial requirements must meet compliance
SIGN PERMIT Attach (2) sets of Engineered Plans.
—PROPERTY SURVEY required for all NEW construction.
Directions:
Fill out application completely.
Owner & Contractor sign back of application, notarized
If over $2500, a Notice of Commencement is required. (A/C upgrades over $7500)
Agent (for the contractor) or Power of Attorney (for the owner) would be someone with notarized letter from owner authorizing same
OVER THE COUNTER PERMITTING (copy of contract required)
Reroofs if shingles Sewers Service Upgrades A/C Fences (PlottSurvey/Footage)
Driveways -Not over Counter if on public roadways..needs ROW
813-780-0020 City of Zephyrhills Permit Application Fax-813-780-0021
Building Department
NOTICE OF DEED RESTRICTIONS: The undersigned understands that this permit may be subject to "deed" restrictions" which may be more restrictive
than County regulations. The undersigned assumes responsibility for compliance with any applicable deed restrictions.
UNLICENSED CONTRACTORS AND CONTRACTOR RESPONSIBILITIES: If the owner has hired a contractor or contractors to undertake work, they
may be required to be licensed in accordance with state and local regulations. If the contractor is not licensed as required by law, both the owner and
contractor may be cited for a misdemeanor violation under state law. If the owner or intended contractor are uncertain as to what licensing requirements
may apply for the intended work, they are advised to contact the Pasco County Building Inspection Division —Licensing Section at 727-847- 8009.
Furthermore, if the owner has hired a contractor or contractors, he is advised to have the contractor(s) sign portions of the "contractor Block" of this
application for which they will be responsible. If you, as the owner sign as the contractor, that may be an indication that he is not property licensed and is
not entitled to permitting privileges in Pasco County.
TRANSPORTATION IMPACT/UTILITIES IMPACT AND RESOURCE RECOVERY FEES: The undersigned understands
that Transportation Impact Fees and Recourse Recovery Fees may apply to the construction of new buildings, change of use in existing buildings, or
expansion of existing buildings, as specified in Pasco County Ordinance number 89-07 and 90-07, as amended. The undersigned also understands, that
such fees, as may be due, will be identified at the time of permitting. It is further understood that Transportation Impact Fees and Resource Recovery
Fees must be paid prior to receiving a "certificate of occupancy" or final power release. If the project does not involve a certificate of occupancy or final
power release, the fees must be paid prior to permit issuance. Furthermore, if Pasco County Water/Sewer Impact fees are due, they must be paid prior
to permit issuance in accordance with applicable Pasco County ordinances.
CONSTRUCTION LIEN LAW (Chapter 713, Florida Statutes, as amended): If valuation of work is $2,500.00 or more, I certify that I, the applicant,
have been provided with a copy of the "Florida Construction Lien Law —Homeowner's Protection Guide" prepared by the Florida Department of
Agriculture and Consumer Affairs. If the applicant is someone other than the "owner, I certify that I have obtained a copy of the above described
document and promise in good faith to deliver it to the "owner prior to commencement.
CONTRACTOR'S/OWNER'S AFFIDAVIT: I certify that all the information in this application is accurate and that all work will be done in compliance with
all applicable laws regulating construction, zoning and land development. Application is hereby made to obtain a permit to do work and installation as
indicated. I certify that no work or installation has commenced prior to issuance of a permit and that all work will be performed to meet standards of all
laws regulating construction, County and City codes, zoning regulations, and land development regulations in the jurisdiction. I also certify that I
understand that the regulations of other government agencies may apply to the intended work, and that it is my responsibility to identify what actions I
must take to be in compliance. Such agencies include but are not limited to:
Department of Environmental Protection -Cypress Bayheads, Wetland Areas and Environmentally Sensitive
Lands, WaterNVastewater Treatment.
Southwest Florida Water Management District -Wells, Cypress Bayheads, Wetland Areas, Altering
Watercourses.
Army Corps of Engineers -Seawalls, Docks, Navigable Waterways.
Department of Health & Rehabilitative Services/Environmental Health Unit -Wells, Wastewater Treatment,
Septic Tanks.
US Environmental Protection Agency -Asbestos abatement.
Federal Aviation Authority -Runways.
1 understand that the following restrictions apply to the use of fill:
Use of fill is not allowed in Flood Zone W" unless expressly permitted.
If the fill material is to be used in Flood Zone "A", it is understood that a drainage plan addressing a
"compensating volume" will be submitted at time of permitting which is prepared by a professional engineer
licensed by the State of Florida.
If the fill material is to be used in Flood Zone "A" in connection with a permitted building using stem wall
construction, I certify that fill will be used only to fill the area within the stem wall.
If fill material is to be used in any area, I certify that use of such fill will not adversely affect adjacent
properties. If use of fill is found to adversely affect adjacent properties, the owner may be cited for violating
the conditions of the building permit issued under the attached permit application, for lots less than one (1)
acre which are elevated by fill, an engineered drainage plan is required.
If I am the AGENT FOR THE OWNER, I promise in good faith to inform the owner of the permitting conditions set forth in this affidavit prior to
commencing construction. I understand that a separate permit may be required for electrical work, plumbing, signs, wells, pools, air conditioning, gas, or
other installations not specifically included in the application. A permit issued shall be construed to be a license to proceed with the work and not as
authority to violate, cancel, alter, or set aside any provisions of the technical codes, nor shall issuance of a permit prevent the Building Official from
thereafter requiring a correction of errors in plans, construction or violations of any codes. Every permit issued shall become invalid unless the work
authorized by such permit is commenced within six months of permit issuance, or if work authorized by the permit is suspended or abandoned for a
period of six (6) months after the time the work is commenced. An extension may be requested, in writing, from the Building Official for a period not to
exceed ninety (90) days and will demonstrate justifiable cause for the extension. If work ceases for ninety (90) consecutive days, the job is considered
abandoned.
FLORIDA JURAT (F.S.tj3)
OWNER OR AGENT
Subscrib d and sw o (or affir edLbbefore me t
R by Q? ®5-
Who is/a a persgea ly knownAo me or haslhave pr
'tW,1 7 Fi } as identification.
affirmed) before me this
telo
-t�i me or has/have produced
as identification.
otary Publics t B 6 _ Notary Public
�Commission No. ce� 1-7 y C mmission No.(0)
`-i'Q�-'•'ia �..; H`�...-.%M__°� ra_..i L�,a..l...__ �._,.>f iVot�,,C c
Name orNotary typed, panted or stamped Name oary typed, printed or stamped
Notary Public State of Floridr,"
4111111111% My rikf" � lrral Commission HH c
Expires•.
Notary Public State of Florida
Patricia A Nasrallah
6111 My Commission HH 365776
Expires 6/17/2027
INSTR#2023169305 OR BK10890 PG478 rage 1 •
! i ' • .9 10.00 ! i!i •!!
Nikki • a Pasco County Clerk & Comptroller
Document Prepamd By:
cros Axton
610 E Zack St, Ste 110-30B5, Tamp., FL 33602
NOTICE
Permit Number
Folio/Parcel • r •. i •• 0 •.. •
Tax
37340 PICKETTS MILL AVENUE, ZEPHYRHILLS, FL 33542
2, General description of improvement: Install Photovoltaic Solar
3. Owner information:
a. Name and address: BOISSEALI CRAIG THOMAS & ALiSON 37340 PICKETTS MILL AVE ZEPHYRHILLS, FL 33542-1814
b. Phone number: 407-595-3015
Contractor:c. Name and address of fee simple titleholder (if other than owner):
4.
b. Phone number: 888-801-2030
5. Surety:
a. Name and address: N/A
b. Amount of bond $: c. Phone number:
Lender:6.
a. Name •address:
••.
t Phone"•' ■
Lienor's Notice as provided in Section 713.13(l) (b), Florida Statutes:
•ifferent date is specified
WARNING TOOWNER: ANY PAYMENTS MADE BY THE OWNER AFTER THE EXPIRATION OF THE NOTICE OF
COMMENCEMENT ARE CONSIDERED IMPROPER PAYMENTS UNDER CHAPTER 713, PART I, SECTION 713.13, FLORIDA STATUTES,
AND CAN RESULT IN YOUR PAYING TWICE FOR IMPROVMENTS TO YOUR PROPERTY. A NOTICE OF COMMENCEMENT MUST BE
RECORDED AND POSTED ON THE JOB SITE BEFORETHE FIRST INSPECTION. IF YOU INTEND TO OBTAIN FINANCING, CONSULT
WITH YOUR LENDER OR AN ATTORNEY BEFORE COMMENCING WORK OR RECORDING YOUR NOTICE OF COMMENCEMENT.
Craig Thomas Boisseau, Owner
Owner or Owner's Authorized Officer/Director/Partner/Manager Signatory's Printed Names and Tile/Office
STATE OF FLORIDA, COUNTY OF Broward Notarized online using audio -video communication
rvr
The foregoing instrument was acknowledged before me by means of ❑ physical presence or online notarization this 13th day of
September 23 Craig Thomas Boissea Owner
, 20 ^ by name of person) as (type of authority: e.g., officer, trustee,
attorney in fact) for (name of party on behalf of whom instrument was executed)® who is personally
known to me or who has produced DRIVER LICENSE as identification.
ignature of Notary Public
\``\t\UlaYlt?P011yll RAYMOND D STONECIPHER Verification Pursuant to Section 92.525. Florida Statutes
/o % ' Notary Public - State of Florida Under penalties of perjury, I declare that I have read the foregoing and
a/2 P 1= that the facts stated in are true to the best of my knowledge and belief
Q Commission # HH 162425
A;
,�f� of n t � �� Expires on Ajg,:xt S, M2 Signature of Natural Person Signing Above
SUNBILITY
Sunbility, LLC
1103 S. 90,h Street (888) 801-2030
Tampa, Ft 33619 www.sunbility.com
INSTALLATION AGREEMENT EC13008424 info@sunbility.co
#
raig.boisseau@gmaii.com
,.
rhills
€ ,.
.i ,`•
JJ
•r • ti�
i I
i
Utility: a
HOA Phone Number:
:
HOA Email:
r
Estimated 1st Year Productionit.rkWh ,.J
Rating:�4l;MountIII
Type:+f IIIIII
Module:
* IIIIII IIIIII
» I ' :
Stories:
;, ill i ' •
Storage:
.:}..
We w h Dd its Real 1st
,. Rers we lacer sootlsg matanais davm to . Additw i layers removed ate billed :R M per squere.
.. Re-nad ail de"l" pet Rw+da Btilklinq Cade, 11 twd er mcten wets Is dtcavered, n m l be replaces# at a pace of $100 per shoet. 2 Stlaers at
decker irtptR 10d,
Ixtta{S Ice aad Water shield at val
Install Synthetx daymerrt over d kirrg.
Install IKO Cambr" (COLOR TBO I
- Iosta t T" ndga verzt
hwad n HVAC Vents
CkAbn Up aA Pb Pitatod dabvVi
- Provide 7 yr vrotli n srep aaawly,
Not lra„uded : SoW Pane, Satan Tubes d Sky ghts Disconnect, Removal. ReCon,�M or Repdacean M trniess spectied >n lstrttate
- Not tnefuded Gutters Replactt lwil. (WWS wilt be removed trot rp0' to insia#I drip edge, Third party at awmm expense to reinstall.
Then We w s €nstat Solar
r s
otal Contract Amount: $45,851 .JQ
Method Of Payment
Cash Schedule
3 Deposit: $ 13,755.45
7 At install; $ 2,096, }
Financed
initial Payment:$-
lif there are no prepayments made, the remaining payments: $-
The above prices, specifications and conditions are hereby accepted. Payment will be made as outlined above. Any alteration or
deviation from the above specifications involving extra costs will be executed upon written order, and will become an extra charge
over and above the estimate. All agreements are contingent upon strikes, accidents, or delays beyond our control.
uWay n9 �s ,
0Kc US o-THOMAS EN&WEWNG
Craigp # �#'''( p'� g Q ^ (( GRGLW LLC
Boisseau dGr" 141000000 187%gEA4130
Owner: 002707 { r#iq Suability Representative: �M
you do not want the goods or services and must be delivered or postmarked before midnight of the third business day
DO NOT SIGN THIS AGREEMENT BEFORE YOU READ IT! YOU ARE ENTITLED TO A COPY OF THIS AGREEMENT AT THE
TIME YOU SIGN.
I hereby cancel this transaction:
RM
on
GODWIN ENGINEERING AND DESIGN, LLC
8378 Foxtiil Loop, Pensacola, FL 32526 1(850)712-4219 1
September 15, 2023
To: Zephyrhills Building Department
5335 8th St.
Zephyrhills, FL 33542
Subject: Boisseau - Residential PV Roof Mount Installation
37340 Picketts Mill Avenue
Zephyrhills, FL 33542
To whom it may concern,
This letter is regarding the proposed installation of a rooftop -mounted Solar PV system on the existing residential
structure at the subject address. I have reviewed the attachment plan and have determined that the rooftop -mounted PV
system is in compliance with the applicable sections of the following Codes as amended and adopted by the jurisdiction
when installed in accordance with the manufacturer's installation instructions:
2020 Florida Building Code 7 th Edition, FBC
ASCE 7 Min. Design Loads for Buildings & Other Structures
Design Criteria: Design Wind Speed(Vult) - 140 mph 3sec gust, Exposure Category - C, Risk Category 11
The rooftop -mounted photovoltaic panel system has been designed in accordance with FRC R324.4. When roof
penetrations are necessary, they shall be flashed and sealed in accordance with the manufacture's installation instructions,
R905,17.3. The PV system consist of the modules, railing, and connection hardware. Refer to the specific roof type
calculation pages for PV dead loads. The portions of the existing structure covered with solar panels will be adequate for
supporting the roof loads per R324.4.1.1.
The securement method of the the PV system is to be mounted parallel to the structure with the site specific railing and
attachments according to the designed plans. The site specific wind load calculations for the module and their supports are
attached with this document. Fasteners shall be installed to the designated roof member with the proper torque from the
manufactures installation instructions.
The design wind pressures for rooftop solar panels located on enclosed or partially enclosed buildings of all heights, with
panels parallel to the roof surface with a tolerance of 2' and with a max height above the roof surface, h2, not exceeding 10 in.
A min gap of 0.25 in shall be provided between all panels with the spacing of gaps between panels not exceeding 6.7 ft. in
addition the array shall be located at least 2h2 from the roof edge, a gable ridge, or a hip ridge.
It is the contractors responsibility to review all drawings for accuracy and notify the FOR of any discrepanices prior to
beginning construction. To the best of my knowledge, the plans and specifications comply with the minimum requirements
of the latest Florida Building code.
Please see attached documents and contact me should you have any questions.
Sincerely,
D. Chad Godwin, PE 81360
Exi). 02/28/2025
Page 1
GODWIN ENGINEERING AND DESIGN, LLC
8378 Fox tai I L cluop, Pei is a co I a, F L 32526 1(850)712-4219 1
Roof Structure Details
Roof Angle 21* to 27'
RoofType Hip
Roof Covering Asphalt Shingle
Mean Roof Height is ft
Rafter Spacing 7 4 in C.C.
Rafter/Truss Size 2 x 4
Soisseau - Residential Calculations Sheet - RI-R4
The securement method of the PV system is to be mounted parallel to the Asphalt Shingle
roof with the K2 44-X railing and K2 Splice Foot X flashings/attachments. The mounts should
be staggered, where possible, to allow distribution of the design loads evenly to the
structure. The mounts shall be installed with (2) K2 Wood Screw, M5 x 60mm, SIG 0.42, to
Rafter
Wind Load Pammaters
Wind Speed (ascl)
Effective Wind Area
Wind Directionality Kd
Topographic factor Kn
Ground Elevation Factor K,
Velocity Exposure Coefficient K,
Array Edge Factor -/ E
Array Edge Factor YE
Solar Panel Equalization Factor .
!a
Velocity Pressure qh
Added Safety Factor
Allowable Pullout per mount
0.4h or 0.6h
10% of least horizontal dim
Roof Zone Set Back a
h2
2h2
ELL
c12
O.Sh
108
mph FRC R301,2.1.3 Basic Wind Speed (Ult) 140 Tn-ph
it 2 26.20 Exposure Cat. C B,C, or D
Table 26.6-1 Elevation <1000 ft
26.8 or 26.8.2 bldg. least hori. dim (typ.) 360 in
Table 26,9-1 Roof Height 15.00 ft
Table 26.10-1 Exposed Module Definition
Exposed 29.4.4 Exposed factor = 1.5 for uplift loads on panels that are
Non. Exp 29.4.4 exposed and within a distance 1.5(L,) from the end of
row at an exposed edge of the array. Modules are
Fig. 29.4-8
psf q,,=0.00256 K,K,,condidered Exposed ifd, to the roof edge > 0.5h and
K,K,V' one of the following applies:
lbs 1. or to adjacent array > Oft.
ft Flat- o6h, Gab/Hip - 0.4h 12. d, to the next adjacent mod > 4ft.
ft 10% of least her. Dim. Or Oar, whichever is smaller, but not less than either 4% of Least her.
ft Or 3ft, (flat roof - 0.6h)
in Not > loinipariel height above roof)
in 'min distance array shall be from the roof edge, Gable Ridge, or hip ridge
in min gap between all panels but not > 6.7ft
it Horizontal distance Orthogonal to panel edge
ft Horizontal distance from edge of one panel to the nearest edge in the next row
ft
PV Attachment - Results
21.34
0.85
1.00
100
0,85
1.50
1.00
0.67
21.75
1.1
507.0
6.00
100
3.00
5
10
---- 5.25
1.00
0.25
7.50
1
GCp - Uplift 13
GC, - Down 03
P = qh(GCp)(gE)(Ya)UP -25.6
P = qh(GCp)(gE)(yz)UP -161
p = qh(GCp) (g,) (y.) Down 16.0
P = qh(GCP) (90 (y.) Down 16,0
Point load (Portrait Rails) -322
Point load (Portrait Rails) -304.5
Point Load (landscape Rails) -261.1
Point Load (landscape Rails) -754.8
Max Span (Portrait) 48
Max Span (Portrait) 72
Max Span (landscape) 72
Max Span (landscape) 72
Cantilever (Portrait) 16
Cantilever (Portrait) 24
Cantilever (landscape) 24
Cantilever (landscape) 24
*** Spans with A4afk44fiaiI
Pit Dead Load
Rl-R4
Roof Zones
- Hip 21' to
27'
psf 29A-7 Exposed
psf 29.4-7 Non-Exp.
psf 29.4-7 Exposed
psf 29.4-7 Non-Exp.
lb p a A,,, Exposed
lb p A., Non-Exp.
lb p AeR Exposed
lb p Aef, Non-Exp.
in Exposed
in Non-Exp.
in Exposed
in Non-Exp.
2e
2r
3
-1.8
-1,8
-1.8
0.7
0.7
0.7
-36.5
-36.5
-36.5
-23A
-23A
-23.4
16.0
16.0
16,0
1&0
16.0
1610
-459
-459
-459
-441A
-441.4
-441A
-372.3
-372.3
-372.3
-238.9
-238.9
-238.9
48
48
48
72
72
72
72
72
72
72
72
72
16
1 16
1 16
1
1
in Exposed
in Span 33% Non-Exp.
in Exposed
in on -Ex
Specifications
24
24
24
24
24
24
24
denote
24
allowable
24
Module
pressure rating
SIL400
is exceeded.
HC+ Module
QTY of Modules (24 in Portrait, 2 in Landscape)
Module Area
Rail, Clamps, Mounts
Total Rail Length
Module Wm.d
Array Wm.ds
Micro/optimizer Won,,
PV Rail Wpvaii
Total Weight Wt-I
Total Area AT
Dead Load D,
Weight/attachment
Fastener Allowable Pullout
26
ft 2
lb/ft
ft
lbs
lbs
lbs
IDS
lbs
2
it
psf
its 1
F
CLAMPING AREA
PORTRAIT RAIR,
ROOF ATTACHMENT
Pv MODULE al!
Ii-;AD OF Row E(
LANDSCAPE RAIL
XA
14 AL
A(ft) B (ftJ C in Din E in
34
21,34
1
1
19
192
2
N47
1 222
104
192
1518
554.94
2.73
253
(2) K2 Wood Screw, MS x 60mm, SG 0.42
6.28 3.40 12.09 12.09 0.00 0.00
Diameter
S.G.
Thread Embedment per
If of Fastener
I Pullout Value (Source - NOA)
5mm
Module -load -ratings Jpsft
Ultimate
Allowable(ult
/1.5)
0.42
in Page 2
lbt
Load Rating - Snow
Load Rating - Wind
Load Rating - Snow
Load Rating -Wind
113.4
75.6
Portrait
0.46875
-113.4
-75.6
4
113.4
75.6
Landscape
507.0
-113A
-75.6
0
so
Inverter Type:
(26)Enphase IQ8PLUS-72-2-US
PV Panel:
(26) SIL-400 HC-k
Racking:
K2
Total Wattage:
10,400W DC
Roof Type:
Composition Shingles
Wind Load:
21 to 27 Deg
Fastener Type:
Use K2 Splice Foot
Sheet Index
S-1
Cover Sheet / Site Plan
S-2
Detail
E-I
One - Line
E-2
Electrical Code
S-IA Mounting Plan
General Notes:
-Enphase IQ8PLUS-72-2-US Micro Inverters
are located on roof behind each module.
-First responder access maintained and
from adjacent roof.
-Wire run from array to connection is 40 feet.
Tampa, FL 33619
1-888-801-2030
3'
�egend YZ71 JI'7-A' First responder access
Gf'OUnd Access Chimney
Utility Meter Satellite
0
Vent Pipe
PV Disconnect
FRONT OF HOUSE
r2=11"MIA&SIM
®1
# Modules (17)
Pitch: 24'
Azimuth: 27 1'
System meets the requirements of NFPA 70th Edition, Chapter ]:! 1,12 (2018 Edition) Install will be done to Manufacturer Spec
Meets All Editions of Florida Fire Prevention Code 2020 7th Edition
Meets all requirements of 2018 Editions of NFPA- I and NFPA- 10 1
hwa
Represents all Fire Clearance I st Responder Access
including Alternative methods minimum of 36" unobstructed as per
Section R324 of the 2020 IRC
Meets the requirements of the following- (2020 FL Residential Code & FBC, 7th Edition (2020 International
Residential Code) - 2nd Printing modified by the FL Building Standards, 2020 Florida Building Energy
Conservation Code 7th edition, City of Zephyrhills Code, 2017 National Electric Code.)
CRAIG THOMAS & ALISON
BOISSEAU
37340 PICKETTS MILL AVENUE
ZEPHYRHILLS, FL
33542
-COGEN Disconnect
Located adjacent to
Utility meter
Layout Subject to Change
rwra, M-Mmmumpm
Design, LLC
8378 Foxtail Loop
Pensacola, FL 32526
D. Chad Godwin, PE
Chad(o,godwineng.com
I M11111011JR&T "M
K
-Revised by:
I MAC
Roof Type:
Roof Pitch & Overhang:
Structure:
Sealing/Flashing:
Extra Notes:
RI-R4
Composition Shingles
5/12; 12" Overhang
K2 Splice Foot
(2) M5x0rnrn SS Screws into Roof Rafters
2"x4" Wood Trusses g 24" O.C.
All penetrations are sealed and flashed
Rafter S ans
Ex osed
Non -Ex -ed
-Roof Height 15'
-Per 2020 FBC, the Roof Mounted PV Syste
will be subject to the following design criteri
Design Wind Speed(Vult) - 140mph 3 see guls
Exposure Category - C
-Designed as per ASCE7-16
Inverter Type:
(26)Enphase IQ8PLUS-72-2-US
PV Panel:
(26) SIL-400 HC+
Racking:
K2
Total Wattage:
10,400W DC
Roof Type:
Composition Shingles
Wind Load:
21 to 27 Deg
Fastener Type:
Use K2 Splice Foot
CRAIG THOMAS & ALISON
BOISSEAU
37340 PICKETTS MILL AVENUE
ZEPHYRHILLS, FL
33542
Install will be done to
Design, LLC
8378 Foxtail Loop
Pensacola, FL 32526
D. Chad Godwin, PE
�v Chad(�.�gow, ineng.corn
FL 33619
1-888-801-2030
I IT
Drawn by: 1K
I RTN.-WA 11 -
Rev Date: -
Page:
12-2 Romex can be used for interior
building and attic runs only. Do not use
romex in conduit or outdoor
environments.
410 AWG THWN for Home runs
(1) Line I
(1) Line 2
2 Circuits
(1) FCC
Inside @ least 3/4" Conduit (tbd on site)
Enphase Output C kt Per String
To Overcurrent Protection- Device
AC Max Output Current 15.73
AC Max Output Current * 125%
19.7
Overcurrent Protection A 20
No. of Current Ca wryinngCond - ------ <4
Conductor Gauge (AWG) 10
Enphase Total Output Ckt
- -- -------------- --- -
AC Max Output Current __ - - - 3-1.46
AC Max Output Current 125% 39.3
Overcurrent Protection (A) 40
No. of Current Carrying Cond <4
Conductor Gauge (AWG)
8
Including the label below
In Case of Emergency Call
Sunbty at
888-801-2030
Meets 11.1.2.2.1.5
NENIA3R
Junction Box
Black - L I
Red - L2
Green - Ground
NEC LABEL NOTES:
1 THE WARNING SIGN(S) OR LABEL'S) SHALL COMPLY
WITH NEC 11021(B)
2. LABELS SHALL BE SUITABLE AbLt FOR I HE ENVIRONMENT
'AIHERE THEY ARE INSTALLED-
3, LABELS TO BEAMIN LETTER HEIGHT OF 3/8"AND
Photovoltaics:
PERMANENTLY AFFIXED.
C
Enphase IQ Trunk able�
4. LABELS SHALL ALSO COMPLY V\ATH THE SPECIFI C
REQUIREMENTS OF THE AUJ I IORITY HAVING
1 (26) SIL-400 HC+
JURISDICTION.
Q- 12-240
#12AWG THHN-THWN-2
Inverters.
UL 9703
(26) Enphase IQ8PLUS-72-2-US Micro Inverters
Grounding Conductor to be protected 1 Circuits:
#8 Awg or to be unprotected #6 Awg
(2) circuits of (13) Modules
250.64(B) 250.66 0.66 & 2 5 0.120(C)
Maximum Inverters Per 20A Circuit (13)
Roof
PHOTOVOLTAIC SYSTEM
AC DISCONNECT!
I RATED AC OUTPUT CURRENT: 3146A
NOMINAL OPERATING VOLTAGE: 240VAC
Enphase Combiner Box
4X-IQ-AMI-240
lavl5A
-
201v-----
0
'T�
20A
Envoy
Monitor
Main Service Panel
150A Main
Supply Side Tap
k4anual Lockable Disconnect
fi0A Service Rated
Hled Disconnect
40A Fuses
I AC Disconnect
L
Located Adjacent to UnIfty Meter
Conduit (in) I L1,L2,N (Awg)l Ground (Awg) OCPD
After 1 8 0.75 1 8 8 40
,ner
To Line Side Tap C 035 6 N/A 40
Note:
-All wiring to meet the 2017 NEC and
Florida electric codes.
60A Disconnect
-Type of conduit to be determined
on site by contractor.
Install will be done to Manufacturer
GEC NOTE'S
- Ungrounded system per 690A 1 (A)(4)
- GEC must be installed per 250.64
- 61J.' must be continuous tin -spliced or irreversibly spliced from
inverter to existing service ground s%1stem or continuous from the
arrays to the existing service ground system.
F '
- GC must be min ;8 AWG and installed in conduit
- L('GEC is not in conduit, it most be 46 min
Disconnects will be Visible, lockable, adjacent to
and within 5' of utility meter
All Labels & Markings for photovoltaic system will be
reflective and meet all requirements for NFPA 1: 11: 12
M
M
In Compliance with
NEC 705. 12(A)
Disconnect is in compliance 230.72
Line Side Tap will be done in Main Service Panel Located Inside House
Refer to NEC 312 8 for
Conditions on raps in sw
and over current devices
Enclosures.
Ifthe conditions are not
met a tap box will
need to be installed
I and revision corrudeted
CRAIG THOMAS & ALISON
BOISSEAU
37340 PICKETTS MILL AVENUE
ZEPHYRHILLS, FL
33542
Design, LLC
p
I Loo
8378 Foxtail Loop
I FL 325 Pensacola, c7 26
D. Chad Godwin, PE
�v Chad(godwineng.corn
C_
n4�
N GE
4
1360 "1
Is
ACE OF
0
(5"
Tampa, FL 33619
1-888-801-2030
Date: 09/13/2023
Inverter Type:
Drawn by: IK Enphase IQ8PLUS-72-2-US
Revised b PV Panel:
(26)
Rev #: 00 SIL-400 HC+
Rev Date: Total Wattage:
10,40OW DC
W - �-MM �W
Disconnect Labeling Electrical Calculations
NEC 225
- Disconnect means shall be provided for disconnecting all ungrounded
conductors that supply or pass through the building or stricture Per Code
2017 NEC Section 225.31 & Section 225.32
NEC 230
- If multiple service disconnects are present, grouping of disconnects will be
done per NEC 230.72
NEC 690
Rapid Shutdown Built in Per Code NEC 690.12
E04. Construction documents specify PV system circuits installed on or in
buildings include a rapid shutdown function that controls specific
conductors in accordance with NEC article 690.12.
- E05. These construction documents specify that a label is provided with the
method to initiate rapid shut down per 690.12(4).
- E06. Construction drawings specify buildings or structures with both utility
service and a PV system, complying with NEC article 69012 shall have a
permanent plaque or directory including the following wording: "PHOTO
VOLTAIC SYSTEM EQUIPPED WITH RAPID SHUTDOWN" as per
NEC article 690.56 (C).
- E07. Construction documents specify PV power circuit labels shall appear
on every section of the wiring system that is separated by enclosures, walls,
partitions, ceilings, or floors.
- E08. Construction documents specify all warning sign(s) or label(s) shall
comply with NEC article 110.21 (B). Label warnings shall adequately warn
of the hazard. Labels shall be permanently affixed to the equipment, and
Labels required shall be suitable for the environment.
NEC 705
PV AC disconnect is lockable in the open position per code NEC 705.22(7)
Photovoltaic AC disconnect shall be capable of being locked in the open
position per NEC article 705.22(6).
- Photovoltaic AC Overcurrent protection shall be located within 10 feet of
the point where conductors are connected to the service per NEC 705.31.
- In compliance with NEC 250.58, NEC 690.8, NEC 250.24, NEC250.24(D)
- System meets the grounding requirements of NEC 690.43
Grounding Electrode:
- All grounding Electrodes will be at meter or MDP
- Ground Rods to be at least 8' long and 5/8" in diameter per NEC
250.52(A)(5)
- Add supplemental electrode as required
- System meets requirements ofNEC250.50
IMi -.
- All Exterior equipment is a minimum of Nema-R3 Rated
- Smoke Alarms per E.S. 553.883
- All Electrical Service Equipment shall be located at or above BFE+I' or
8.00' NAVD
um
- Install will be done to Manufacturer Spec
- Service Conductors are Parallel
- No interconnections to be performed on inside panels unless stated by the
contractor.
- The Contractor shall Be responsible for verifying all existing conditions,
and for conforming with these drawings in the event of any unforeseen
circumstances.
- Plans Satisfy NEC 250.94 & NEC250.53(A)(2)
Note:
- Subject PV Systems has been designed to meet the requirments of the NEC
2017, and those set forth by the Florida Solar Energy Center Certification,
Including Maximum Number of Module Strings, Maximum number of
modules per string, Maximum Output, Module Manufacturer and model
number, inverter manufacturer and model number, as applicable.
- Markings shall be placed on all DC Conduits, DC Combiners, Raceways,
Enclosures, .function Boxes, and Cable Assemblies at every 10% turns, and
above and below penetrations in compliance with NFPA
- All Interactive System(S) Points of interconnection with other sources shall
be marked at an accesible location at the disconnecting means as a power
source and with the rated ac output current and the nominal operating AC
voltage. Per NEC 690.54
- Labels will be placed in the correct location Per Code NEC 690.56(B),
690.56(C), & 690.53
- Include required label for metallic raceways and conduits per NEC article
690.31(G)(3).
- Add required label per NEC article 705.10.
- Markings Shall Be reflective, Weather Resistant and suitable for the
environment.
- Markings Shall be red with white lettering with minimum 3/8" Capital
Letters
- NEC 705.10 A permanent plaque or directory, denoting the location of
all electric power source disconnecting means on or in the premises, shall
be installed at each service equipment location and at the location(s) of
the system disconnect(s) for all electric power production sources capable
of being interconnected. One sign required for each PV system.
I SOLAR PV SYSTEM EQUIPPED
3/8 IN MIN. TEXT WITH RAPID SHUTDOWN
TURN RAPID
SHUTDOWN SWTCH TOE,
3116 IN MIN. TEXT THE "OFF" POSITION TO
SHUT DOWN PV - 1�
SYSTEM AND REDUCE'.
SHOCK HAZARD IN THE
ARRAY.
a
Inverter Output Ckt
To Overeurrent Protection Device with Copper
_
Design Temperature(F)
Max Amb Temp Range(F)
941
87-95
310.15i8)(2){a)
Temp Rating of Conductors (C)
75`C
Current Carrying
AC Max Output Current
14
31A
310.15(13)(3)(a)
694.8(A)(3)
AC Max Output Current " 1.25%
39A
699.E(B)
OvercurrentProtect9on(A)
Amp Temp Correction Factor
40A
4.94
3101S(B)(2)(a)
Raceway Fill adjustment Factor
100
310.15(8)(3)(a)
Wire Size(Awg)
Cond Allowable Arrnpacity(A)
8
54A
314.15(B)(16)
Cond AdjustedAmpacity{A)
47A
50A'1'0.94=47A
Ampacity Check 1 Per 69U(8)(1)
Ampacity Check 2 Per 690.8(8)(2)
Pass
Pass
31.46A"1.25-40A<S0A Pass
54A"0.94A'1=47A>31 46A Pass.......
Combiner box in compliance__.
Per Code NEC 705.12
2* 20A < 125A
*No other loads to be added ON SITE GENERATION UTILITY DISCONNECT SWITCH
In Case of Emergency
Sunbilitv at
888-801-2030
TURN RAP D SHU`s DO4�"
SW7CH TO THE 'OFF
POSITION TO SHUT DOWN
THE ENTIRE PV SYSTEM,
"iEOo"5t}.$ri,Ct,7) AND NF'FA"'1.122111 1,11 !72.3.4
Godwin Engineering and
Design, LLC
8378 Foxtail Loop
Pensacola, FL 32526
D. Chad Godwin, PE
Chad@godwineng.com
4628 Eagle Falls Place,
Customer Info: Tampa, FL 33619
1-888-801-2030
Date: 09/13/2023
CRAIG THOMAS & ALISON Inverter Type:
BOISSEAU Drawn by: IK Enphase IQ8PLIJS-72-2-US
37340 PICKETTS MILL AVENUE Revisec� b PV Panel:
)
ZEPLIYRHILLS, FL Rev #: 00 SIL-400HC+
33542 Rev late: Total Wattage:
10,404W Di
Page: 11 "x 17" E-2
an
FIES I N 191 N RXIN
14'
M
9 -Splice Bar
59 K2 Splice Foot
42 K2 Mids
23 K2 Ends/End Caps
4 Roof Top Combiner
6 K2 Ground Lugs
26 SIL-400 HC+
26 Enphase IQ8PLUS-72-2-US
I 60A Fused Disconnect
2 40A Fuses
2 20A 2P Breakers
I Enphase Combiner Box
IrOUXEIMMINIM
F-PARAMOM
R-1
# Modules (17)
Pitch: 24'
Azimuth: 271'
Rafter Spans
Zone I Zone 2e
Zone 2r
Zone 3
E�sed
48" 4811
24"
24"
Non -Exposed
4 48"
48"
48"
6" " 16
I 6 "
16"__'
Max Cantilever = Max Span * 61)
El
N
IN
MMIFWATE
R-4
# Modules (5)
Pitch: 24'
fM IT=
Inverter Type:
(26)Enphase IQ8PLUS-72-2-US
PV Panel:
(26) SIL-400 HC+
Racking:
K2
Total Wattage:
10,400W DC
Roof Type:
Composition Shingles
Wind Load:
21 to 27 Deg
Fastener Type:
Use K2 Splice Foot
R-2
# Modules (3)
Pitch- 240
Azimuth: 181'
a
N
BOI SEAU
37340 PICKETTS MILL AVENUE
ZEPHYRHILLS, FL
33542
IN
� _T — /
R-3
# Modules (1)
Pitch: 24'
Azimuth: 910
IN
E
Exposed
Non -Exposed
Spacing
Spacing
Plans satisfy zones FBC-1510.7A
Install will be done to Manufacturer SDec
Design, LLC
8378 Foxtail Loop
Pensacola, FL 32526
D. Chad Godwin, PE
Chad4godwineng.com
4628 Eagle Falls Place,
Tampa, FL 33619
1-888-801-2030
Date: 09/13/2023
Drawn bv: 1K
I Rev #: 00 1
Rev Date:
Page: I I ?1x1 7" S- lA'1
0 A
6, J
S 0 L A R
RELIABLE ENERGY.
DIRECT FROM THE SOURCE.
Designed to outperform.
solar panels engineered for North
American homeowners.
Sl L FFA BSOL A R,COM
ELECTRICAL SPECIFICATIONS
Test Conditions
Module Power jPmax) Wp
Maximum power voltage (Vpmax) v
Maximum power current (Ipmax) A
Open circuit voltage (Voc) v
Short circuit current (Isc) A
Module efficiency %
Maximum system voltage (VDC) V
Series fuse rating A
Power Tolerance Win
STC
400
36.05
11.10
43,02
11.58
20.2%
400
NOCT
298
33-50
8,910
4035
9.34
18.8%
1000
20
0 to '10
Measurement conditions: STC 1000 W/M2 AM 1S - Temperature 25 °C NOCT 800 Wym2 AM 1.5 - Measurement uncertainty 3%
Sun simulator calibration reference modules from Fraunnofier Institute.
Electrical characteristics may vary by ±5% and power by 0 to +low.
MECHANICAL PROPERTIES/ COMPONENTS
METRIC
IMPERIAL
Module weight
21.3kg ±0.2kg
47lbs t0.4lbs
Dimensions (H x L x D)
1914 mm x 1036 mm x 35 mm
75.3 in x 40-8 in x 1-37 in
Maximum surface load (wind/snow)'
5400 Pa rear load / 5400 Pa front load
llZa lb/ft' rear tied / 112.8 lb/ft' front load
Hail impact resistance
a 25 mm at 83 km/h
a I in at 51.6 mph
Celts
132 Half calls - Si mom PERC
132 Half calls- Si mono PERC
9 bulbar - 83 x 166 mm
9 bulbar- 3.26 x 6.53 in
Glass
3.2 mm high transmittance, tempered,
0.126 in high transmittance, tempered,
DSM antireflective coating
DSM antireflective coating
Cables and connectors (refer to installation manual)
1350 mm, is 5.7 mm, MC4 from Staubfi
53 in, o 0.22 in (12AWG), MCA from StaubB
Backsheet
High durability, superior hydrolysis and LN resistance, multi
-layer dielectric film,
fluorine -free PV backsheet
Frame
Anodized Aluminum (Black)
Bypass diodes
3 diodes-30SQ045T (45V max DC blocking voltage, 30A max forward rectified current)
Junction Box
UL 3730 Certified, IEC 62790 Certified, IP68 rated
TEMPERATURE RATINGS
WARRANT19S
Temperature Coefficient Isc 10.064 %/*C
Module product workmanship warranty 25 years**
Temperature Coefficient Voc -0.28 %rc
Unear power performance
guarantee 30 years
Temperature Coefficient Proax -0.36 %/-C
> 97" 1% end lstg
NOCT (t 2*C) 45'C
e 91.6% end 12t yr
85.1% end 25th yr
Operating temperature -40/185 -C
82.6% end 30th yr
CERTIFICATIONS
SHIPPING SPECS
UL61215-1:2017 Ed.l***, UL61215-2:2017 Ed.l***, UL 61730-1:2017 Ed.l***, UL
0
73 Modules Per Pallet: 26 or 26 lCaliforria)
2:2017Ed.1 ***,
CSAC22.2#61730-1:2019 Ed.2***, CSAC22.2#61730-2:2019 Ed.2,�!
1
Product IEC 61215-1:2016 Ed.l***, IEC 61215-2:2016 Ed,l***, EC 61730-1:2016 Ed.2**', IEC
61730-2:2016 Ed.2**,
EC 61701:2020 (Salt Mist Corrosion), IEC 62716:2013 (Ammonia
Pallets Per Truck 32.,31 (California)
Corrosion), UL Fire
Rating: Type 2, CEC Listing`""
Factory IS09001:2015
Modules Per Truck 832 or 806 (California)
®Warning. Read the Safety and Installation Manual for mounting specifications and before handling, installing and operating modules.
12 year extendable to 25 years subject to registration and conditions
outlined mrider'Warrenty' at
PAN flies generated from 3rd party performance data are available for download at: st6`
Certification and CEC listing in progress. December 2022, expected completion.
jt
sa---
iT, 75.3" [1914mm]
--------
12.1" [307mm]
51.2 [1300rnm]___________ 12.1'-[30-7rr
S "AS SOLAR INC
'I LF
ounting Hole (x4)
+0
800 Cornwall Ave
0 5�
Bellingham WA98225 USA
Ll'2,mm
lii
T +1360.569.4733
info@sitfabsotar.com
F_
A "I S 0 i A P, r� f, M
E 1770 Port Drive
E E
ca T
to E
Burlington WA 98233 USA
T +1 360.56EL4733
240 Courtneypark Drive East
E 0
Mississauga ON L5T 2Y3 Canada
E X
T +1905.255.2501
(]L06*
53.15' 'N
F +1905.696.0267
[1350mm]
Cable Length 2
j Sftbb - SIL-400-NIC+-2022202`7
1wr.,J-Jtxid.rykwi m.U..d W,
rainage Hole (x8)
Q
�p
422. Sieb 5,1,e i, ari�,inf bad—k
J �W Siiftbl—
__ _11_
LW 2 [691m]
�_L____
2OChrilm
ENPHASE, 8= IQ8 and 1Q8+ Microinverters
Our newest IQ8 Microinverters are the industry's first microgrid-forming, software -
defined microinverters with split -phase power conversion capability to convert DC
power to AC power efficiently. The brain of the semiconductor -based microinverter
is our proprietary application -specific integrated circuit (ASIC) which enables the
microinverter to operate in grid -tied or off -grid modes. This chip is built in advanced
55nm technology with high speed digital logic and has super -fast response times
to changing loads and grid events, alleviating constraints on battery sizing for home
energy systems.
RR,
Connect PV modules quickly and easily to
108 Series Microinverters using the included
O-DCC-2 adapter cable with plug-n-play MC4
connectors.
IQ8 Series Microinverters redefine reliability
standards with more than one million
cumulative hours of power -on testing,
enabling an industry -leading limited warranty
of up to 25 years.
108 Series Microinverters are UL Listed as
PV Rapid Shut Down Equipment and conform
with various regulations, when installed
according to manufacturer's instructions.
@ 2021 Enphase Energy. All rights reserved. Enphase, the Enphase logo, IQ8 microinverters,
and other names are trademarks of Enphase Energy, Inc. Data subject to change.
108SP-DS-0002-01-EN-US-2021-10-19
Easy to install
Lightweight and compact with
plug-n-play connectors
Power Line Communication
(PLC) between components
Faster installation with simple
two -wire cabling
High productivity and reliability
Produce power even when the
grid is down
More than one million cumulative
hours of testing
Class 11 double -insulated
enclosure
Optimized for the latest high-
powered PV modules
Microgrid-forming
Complies with the latest
advanced grid support
Remote automatic updates for
the latest grid requirements
Configurable to support a wide
range of grid profiles
Meets CA Rule 21 (UL 1741-SA)
requirements
Commonly used module pairings'
W
235-350
235-440
Module compatibility
60-celf/120 half -cell
60-cell/120 half -cell and 72-cell/144 half -cell
MPPT voltage range
V
27-37
29-45
Operating range
V
25-48
25-58
Min/max start voltage
V
30/48
30/58
Max input DC voltage
v
50
60
Max DC current2 (module Isc]
A
15
Overvoltage class DC port
11
DC port backfeed current
mA
0
PV array configuration
lxl Ungrounded array; No additional DC side protection
required; AC side protection requires max 20A per branch circuit
Peak output power
VA
245
300
Max continuous output power
VA
240
290
Nominal (L-L) voltage/range3
V
240 / 211- 264
Max continuous output current
A
1.0
1.21
Nominal frequency
Hz
60
Extended frequency range
Hz
50-58
Max units per 20 A (L-L) branch circuit"
16
13
Total harmonic distortion
<5%
Overvoltage class AC port
III
AC port backfeed current
mA
30
Power factor setting
1.0
Grid -tied power factor (adjustable)
0.85 leading - 0.85 lagging
Peak efficiency
%
97.5
97.6
CEC weighted efficiency
%
97
97
Night-time power consumption
mw
60
Ambient temperature range
-40°C to +60°C (-40°F to +140°F)
MEN=
Relative humidity range
4% to 100% (condensing)
DC Connector type
MC4
Dimensions (HxWxD)
212 mm (8.3") x 175 mm (6.9") x 30.2 mm (1.2")
Weight
1.08 kg (2.38 lbs)
Cooling
Natural convection - no fans
Approved for wet locations
Yes
Acoustic noise at 1 m
<60 dBA
Pollution degree
PD3
Enclosure
Class
11 double -insulated, corrosion resistant polymeric enclosure
Environ. category / UV exposure rating
NEMA Type 6 / outdoor
CA Rule 21 ILL 1741-SA), UL 62109-1, UL1741/IEEE1547, FCC Part 15 Class B, ICES-0003 Class B, CAN/CSA-C22.2 NO. 107.1-01
Certifications This product is UL Listed as PV Rapid Shut Down Equipment and conforms with NEC 2014, NEC 2017, and NEC 2020 section
690,12 and C22.1-2018 Rule 64-218 Rapid Shutdown of PV Systems, for AC and DC conductors, when installed according to
manufacturer's instructions.
(1) No enforced DC/AC ratio. See the compatibility calculator at https://Iink.enphase.com/
module -compatibility (2) Maximum continuous input DC current is 10.6A (3) Nominal voltage
range can be extended beyond nominal if required by the utility. (4) Limits may vary. Refer to
local requirements to define the number of microinverters per branch in your area. IQ83P-DS-0002-01-EN-US-2021-10-19
X2-IQ AM1-240-4(IEEE 1547:2{018)
df �
LIED
To learn rrlore about Enphase offerings, visit enphase.com
I Q-C-4-4 C-D S-0103- E N- U S-12-29 -20 22
I he )t, L's with IQ Gateway and
integrated L_1 E-fall cell modern (included
only with IQ Combiner 4C) consolidates
Interconnection equipment into a single
enclosure. It streamlines IQ Microinverters and
storage installations by providing a consistent,
pre -wired Solution for residential applications.
1t offers up to four 2-pole input circuits and
Eaton BR series busbar assembly.
Includes IQ Gateway for communication and control
Includes Mobile Connect cellular modem
(CELLMODEM-M1-06-SP-05), included only with
IQ Combiner 4C
Includes solar shield to match Enphase IQ Battery
aesthetics and deflect heat
Supports till Ethernet, or cellular connectivity
Optional AC receptacle available for PLC bridge
Provides production metering and consumption
monitoring
Mounts on single stud wittl centered brackets
Supports bottom, back and side conduit entry
Allows up to four 2-pole branch circuits for 240VAC
plug-in breakers (not included)
80A total Pay or storage branch circuits
Durable NRTL-certified NEMA type 3R enclosure
Five-year limited warranty
Two years labor reimbursement program coverage
included for both the IQ Combiner SKU's
UL listed
X2-IQ-AM1-240-4 and X2-IQ-AM1-240-4C comply with
IEEE 1547:2018 (UL 1741-SB, 31'1 Ed.)
ENPHASE
'v,»
IQ Combiner /
IQ Combiner 4 IQ Combiner 4 with IQ Gateway printed circuit board for integrated revenue grade PV production rnete,ing (ANSI C'12.20+0.5 i)
X-7Q-AM 1-240-4 and consumption monitoring (±2.5i). includes a silver solar shield to match the IQ Battery and IQ System Controller 2 and to
X2-1Q-Aril -240-4 (IEEE 1547:2018) deflect heat.
IQ Combiner 4C IQ Combiner 4C with IQ Gateway printed circuit board for integrated revenue grade PV production metering (ANSI C1220 40.5%)
X-iQ-AM1-240-4C and consumption monitoring (±2.5%) Includes Mobile Connect cellular modem (CEI.LMODEM-MI-06 SP-05), a plug -and -play
X2-IQ-AM I-240-4C (IEFE! 15472018) industrial grade cell modem for systems up to 60 micminverters. (Available in the US, Canada, Mexico, Puerto Rico, and the
US Virgin Islands, where there is adequate cellular service In the installation area-) Includes a silver solar shield to match the
10 Battery and IQ System Controller and to deflect heat.
ACCESSORIES AND REPLACEMENT PARTS (not included, order separately)
Supported microinaerters iQ6 ,Q7, and IQ8. (Do not mix IQ6/7 M€croinserters with iQ8)
Communications Kit
COMMS-CELLMODEM-M1-06
Includes COMMS-KIT-01 and CELLMODEM-MI-06-SP 05 with 5-yearSprintdata plan
CELLMODEM-Ml-06 SP-05
4G based LTE: M1 cell€,alar modem with 5-Year Sprint data plan
CELLMODEM MI 06-AT-05
4G based LTE-M1 cellular modem with 5-year AT&T data plan
Circuit Breakers
Supports Eaton BR210, BR215, BR220, BR230, r3R240, BR250, and BR260 circuit breakers.
BRK-10A-2-240V
Circuit breaker, 2 pole, 10A, Eaton BR210
BRK-15A-2-240V
Circuit breaker, 2 pole, 15A, Eaton BR215
BRK-20A-2P-240V
Circuit breaker, 2 pole, 20A, Eaton BR220
BRK-15A-2P-240V-B
Circuit breaker, 2 pole, 15A, Eaton BR2158 with hold down kit support
BRK-20A-2P-24oV-B
Circuit breaker, 2 pole, 20A, Eaton BR220B with hold down kit support
XA-SOLARSHiELD-ES Replacement solar shield for IQ Combiner4/4C
XA-PLUG-120-3 Accessory receptacle for rower Line Carrier in IQ Combiner 4/4C (required for EPLC-01)
X IQ -NA -HD 125A Hold-down kit for Eaton circuit breaker with screws
Consumption monitoring CT A pair of 200A split core current transformers
(CT-200-S P L I-UCT-200-CLAMP)
ELECTRICAL SPECIFICATIONS
Rating
System voltage
Eaton BR series busbar rating
Max. continuous current rating
Max. continuous current rating (input from PV/storage)
Max. fuse/circuit rating (output)
Branch circuits (solar and/or storage)
Max. total branch circuit breaker rating (input)
IQ Gateway breaker
Continuous duty
120/240VAC, 601iz
125A
65A
64A
90A
Up to four 2-pale Eaton BR series Distributed Generation (DG) breakers only (not included)
80Aof distributed generation/95A with IQ Gateway breaker included
10A or 15A rating GE/Siemens/Eaton included
Production metering C I 200A solid core pre -installed and wired to IQ Gateway
MECHANICAL DATA
.....
.............................
Dimensions (t�7xtixD) 37.5 cm x 49.5 cm x 16.8 cm (14.75 in x 19.5 in x 6-63 in)- Height is 53-5 cm (21-06 in) with mounting brackets.
Weight
T5 kg (16-5lbs)
Ambient temperature range
-400C to +46°C (-40°F to 1 15°F)
Cooling
Natural convection, plus heat shield
Enclosure environmental rating
Outdoor, NRTL-certified, NEMA.type 3R, polycarbonate construction
Wife sizes
20A to 50A breaker Inputs: 14 to 4 AWG copper conductors
60A breaker branch input: 4 to 1/0 AWG copper conductors
Main Ing combined output: 10 to 2/0 AWG copper conductors
Neutral and ground: 14 to 1/0 copper conductors
Always follow local code requirements for conductor sizing.
Altitude
Up to 3,000 meters (9,842 feet)
INTERNET CONNECTION OPTIONS
Integrated Wi Fi IEEE 802.11 b/g/n
Cellular CELLMODEM-M1-06-SP-05, CELLMODEM-M1-06-AT-05 (4G based LTE-M I cellular modem). Note that an Mobile Connect
cellular modem is required for all Enphase Energy System installations.
Ethernet Optional, IEEE 802.3, Cat5E (or Cat6) UT P Ethernet cable (not included)
COMPLIANCE
Compliance, iQ Combiner - - CA Rule 21 (UL1741-SA)
IEEE 1547:2018 - UL 1741-SB, 3r1 Ed. (X2-IQ-AM1-240-4 and X2-IQ-AM1-240-4C)
CAN/CSA C22.2 No. 107.1, Title 47 CFR, Part 15, Class B, ICES 003
Production metering: ANSI C12.20 accuracy class 0.5 (PV production)
Consumption metering: accuracy class 2.5
Compliance, IQ Gateway UL 60601-/CA.NCSA22.2 No. 61010-1
c, 2022 Enphase Energy All right, ileser✓ed . r,rhase, the Friplhose ogo IQ Combiner 4r4C, and other namesare , a eniarrs of
Enphase Energy Inc Data subject to change IQ-C-4-4C-DS-0103-EN-US-12-29-2022
IVIOUnting systems for solar technology
A S S E- IyI 131.11 114 S T 11 U 110 T 10 H S
IVIOLIII-Lillg systems for solar technology
N
N E. W 13 R 0 13 U CO T
w
Part Number
Description
4000019
CrossRail 44-X 166", Mill
4000020
CrossRail 44-X 166", Dark
4000021
CrossRail 44-X 180", Mill
4000022
CrossRail 44-X 180", Dark
4000051
RailConn Set, CR 44-X, Mill
4000052
RailConn Set, CR 44-X, Dark
4000067
End Cap, Black, CR 44-X
------- - -------
www,everest-solarsystems.com Alww. eve re s t - so I a rsystem s. c n m
CrossRail 44-X Product Sheet USOI 10520 Subject to change Product illUstrations are exernplary and may differ From the original.