Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
23-7048 (2)
%City of Zephyrhills 5335 Eighth Street Zephyrhills, FIL 33542 Phone: (813) 780-0020 Fax: (813) 780-0021 FIRE-007048-2023 Issue Date: 10/19/2023 REINSPECTION FEES: (c) With respect to Reinspection fees will comply with Florida Statute 553.80(2)(c) the local government shall impose a fee of four times the amount of the fee imposed for the initial inspection or first reinspection, whichever is greater, for each subsequent reinspection. Notice: In addition to the requirements of this permit, there may be additional restrictions applicable to this property that may be found in the public records of this county, and there may be additional permit required from other governmental entities such as water management, state agencies or federal agencies. M=I I 1 11 111 1111111 11IljI!!Ij 11111 111 !111111 Complete Plans, Specifications add fee Must Accompany Application. All work shall be performed in accordance with City Codes and Ordinances. NO OCCUPANCY BEFORE C.O. NO OCCUPANCY BEFORE C.O. CONTRACTOR SIGNATURE PE IT OFFICE 813-780-0020 City of Zephyrhills Fire Fax-813-780-0021 g-- Permit Application Date ROC Phone Contact for Permit elved i Fee Simple Titleholder Name Fee Simple Titleholder Address D Blo-Hazard Waste Storage - ANNUAL 1:3 Comm Exhaust Kitchen Hood/Duct E3Controlled Bum 0 Emergency Generator < 30 kw HEmergency Generator > 30 kw Fire Protection Maintenance - ANNUAL Sprinkler Fire Alarm Hood Cleaning 0 0 0 Z=002= Hood Suppression 0 11 0 J Fire Alarm Installation Fire Pumps HFlammable Application- ANNUAL Fuel Tanks r-1 Other: F—%,-7,—,TW3S 6V ZJ Contractor Signature Address Titleholder Phone Number Lot # Fumigation Tent Hazardous Material (Tier 11 or RQ Facility) ANNUAL Hood Installation LP/Natural Gas-Installatior LP/Natural Gas -ANNUAL Sale Places of Assembly -ANNUAL Recreational Bum Sparklers Sprinkler System Installati Standpipes (Sprinkler Sys) Torch Rooling/Tar Kettle 'Waste Tire ft= ANNIJ11 Valuation of Project Company I X—',)(— V- i re- "'® Registered JC.,Y2 N F Fee Current License # rE IF —U2711721777- ELECTRICIANI.. Company Signature Registered �/N F— current Address F--"-- License # PLUMBER Company Signature Registered Y N— Fee Current Address License # MECHANICAL Company Signature L Registered Address License # OTHER Company Signature Registered Fee Current Address License # Directions: Fill out application completely. Owner & Contractor sign back of application, notarized (Or, copy of signed contract with owner) If over $2500, a Notice of Commencement is required (Mechanical work over $50001, Supply two (2) sets of drawings with applicable documentation Allow 10-14 days for review after submittal date. Parcel # - obtained from Property Tax Notice (http:ttappraiser.pascogov.com) UNLICENSED CONTRACTORS AND CONTRACTOR RESPONSIBILITIES: If the owner has hired a contractor or contractors to undertake work, they may be required to be licensed in accordance with state and local regulations. If the contractor is not licensed as required by law, both the owner and contractor may be cited for a misdemeanor violation under state law. If the owner or intended contractor are uncertain as to what licensing requirements may apply for the intended work, they are advised to contact the Pasco County Building Inspection Division —Licensing Section at 727-847- 8009, Furthermore, if the owner has hired a contractor or contractors, he is advised to have the contractor(s) sign portions of the "contractor Block" of this application for which they will be responsible. If you, as the owner sign as the contractor, that may be an indication that he is not properly licensed and is not entitled to permitting privileges in Pasco County, TRANSPORTATION IMPACTIUTILITIES IMPACT AND RESOURCE RECOVERY FEES: The undersigned understands that Transportation Impact Fees and Recourse Recovery Fees may apply to the construction of new buildings, change of use in existing buildings, or expansion of existing buildings, as specified in Pasco County Ordinance number 89-07 and 90-07, as amended. The undersigned also understands, that such fees, as may be due, will be identified at the time of permitting. It is further understood that Transportation Impact Fees and Resource Recovery Fees must be paid prior to receiving a "certificate of occupancy" or final power release, If the project does not involve a certificate of occupancy or final power release, the fees must be paid prior to permit issuance. Furthermore, if Pasco County Water/Sewer Impact fees are due, they must be paid prior to permit issuance in accordance with applicable Pasco County ordinances, CONSTRUCTION LIEN LAW (Chapter 713, Florida Statutes, as amended): If valuation of work is $2,500.00 or more, I certify that 1, the applicant, have been provided with a copy of the "Florida Construction Lien Law- —Homeowners Protection Guide" prepared by the Florida Department of Agriculture and Consumer Affairs. If the applicant is someone other than the "owner', I certify that I have obtained a copy of the above described document und prorniuo in wood fuith to duliv,-,f it lu the'uwner" prior to commencement CONTRACTOR'StOWNER'S AFFIDAVIT: I certify that all the information in this application is accurate and that all work will be done in compliance with all applicable laws regulating construction, zoning and land development. Application is hereby made to obtain a permit to do work and installation as indicated. I certify that no work or installation has commenced prior to issuance of a permit and that all work will be performed to meet standards of all laws regulating construction, County and City codes, zoning regulations, and land development regulations in the jurisdiction. I also certify that I understand that the regulations of other government agencies may apply to the intended work, and that it is my responsibility to identify what actions I must take to be in compliance, Such agencies include but are not limited to: Department of Environmental Protection -Cypress Bayheads, Wetland Areas and Environmentally Sensitive Lands, WaterNVastewater Treatment. Southwo3t Florida Water Management Disthct-/VeUe, Cypress Bayheadm' Wetland Areas, Altering Watercourses, - Army Corps ufEnQioeers-GeewmUa.Docks, Navigable Waterways. - Department of Health & Rehabilitative Serviaau/Env|mnmmntm{ Health Unh'VVe||u, Wastewater Tembnent, Septic Tanks. US Environmental Protection Agency -Asbestos abatement. - Federal Aviation Authority-Runwaya. / understand that the following restrictions apply mthe use mml� - Use offill ianot allowed inFlood Zone ^V^unless expressly permitted. ' If the 0| material is to be used in Flood Zone ^/", it is understood that a drainage plan addressing o ''compenoating vo|ume~ will be submitted at time ofpermitting which is pn*penud by a professional engineer licensed bythe State ofFlorida. |fthe fill material is to be used in Flood Zone ^A" in connection with e permitted building using stem wall construction, | certify that fill will be used only tofill the area within the stem wall. If fill material is to be used in any area, | certify that use of such fill will not adversely affect adjacent properties. If use of fill is found to adversely affect adjacent properties, the owner may be cited for violating the conditions of the building permit issued under the attached permit application, for lots less than one (1) acre which are elevated by fill, an engineered drainage plan is required, If I am the AGENT FOR THE OWNER, I promise in good faith to inform the owner of the permitting conditions set forth in this affidavit prior to commencing construction, I understand that a separate permit may be required for electrical work, plumbing, signs, wells, pools, air conditioning, gas, or other installations not specifically included in the application. A permit issued shall be construed to be a license to proceed with the work and not as authority to violate, cancel, alter, or set aside any provisions of the technical codes, nor shall issuance of a permit prevent the Building Official from thereafter requiring a correction of errors in plans, construction or violations of any codes. Every permit issued shall become invalid unless the work authorized by such permit is commenced within six months of permit issuance, or if work authorized by the permit is suspended or abandoned for a period of six ((j) months after the time the work is commenced. An extension may be requested, in writing, trorn the Building Official for a period not to exceed ninety (90) days and will demonstrate justifiable cause for the extension. If work ceases for ninety (90) consecutive days, the job is considered OWNER OR AGENT__4&gA__K&& CONTRACTOR So scribed and sworn to (ol affirmed) before me this Subscri ed ' d swom to (or affirmed ore me is Who ls/arqj���wn to me or hawltaver produce mViAre persona ty izaown to me or ha—sfiri�ve produced as identification, as identification. �-�Notary Public ?m, �rN Public �tary C s si o Commission No, Name. ofNotary tyn*nnmnt^ or starn ' �COMM 18SION y COA EX- �--- ' w.,,"`owW FAI k, NO v Vz M F M 270MMMUMUMEM Fire Alarm System Catalog Data Submittal Contact: Rod Dumas LdumasI@vscfire,com 8003733473 saIes4vscfIre.corn vscfire.corn 6901 Bryan Dairy Road, SLAte 110,j-argo, FL 33777 Lr-- # FPC14-000008, ri-- , EF20001070 YOUR WORLD. PROTECTED, The FireWarden-100X (NFW-100X) is the latest intelligent address- able Fire Alarm Control Panel (FACP) within the FireWarden Series and is a direct replacement for the FireWarden-1 00 (NFW-1 00). The NFW-10OX comes with a pre -installed communicator and supports up to 198 addressable devices (99 detectors and 99 modules). With an extensive list of powerful features, the NFW-100X programs just like FireWarden-100 products, yet fits into applications previously served only by conventional panels. The pre -installed (POTS-COM is a dual technology (POTS and IP) communicator. The POTS transmits system status (alarms, troubles, AC loss, etc.) to a Central Station via the public switched telephone network. The IP communicator's internet monitoring capability sends alarm signals over the Internet saving the monthly cost of two dedi- cated business telephone lines. Although not required, the second- ary telephone line may be retained providing backup communication over the public switched telephone line. Optional cellular reporting is available using the CELL -MOD or CELL-CAB-N. Remote and local programming of the control panel is possible using the FS-Tools Upload/Download utility. Programming databases can be uploaded/down loaded via the panel's USB port (and USB cable) or via an ethernet connection using the (POTS-COM communicator. The USB port also allows for the download or upload of the entire program, history file, walk -test data, current status and system volt- ages by means of a USB flash drive. The power supply and all electronics are contained on a circuit board supported on a new quick install chassis and housed in a metal cabinet. Available accessories include local and remote upload/download software, remote annunciators, and reverse polar- ity/city box transmitter (4XTM). • Listed to UL Standard 864, 1 Oth edition • Pre -installed (POTS-COM Ethernet IP and POTS (Plain Old Tele- phone Service) Central Station Communicator overAlarmNet • Optional CELL -MOD or CELL-CAB-N GSM Central Station Com- municator over AlarmNetO • Automated activation of the NFC-50/100 Emergency Command Center • NFC-FFT Firefighter Telephone option • Compatible with SWIFTO wireless devices • Auto -programming (learn mode) reduces installation time. Reports two devices set to the same address • Four built-in, independently programmable Style Z (Class A) or Style Y (Class B) NAC circuits • Selectable strobe synchronization for System Sensor, Wheelock, and Gentex devices • Notification Appliance Circuit End of Line resistor matching • Four programmable function keys for ease of maintenance • Two programmable relays and one fixed trouble relay • Built-in Programmer • Integral 80-character LCD display with backlighting • Real-time clock/calendar with automatic daylight savings control • History file with 1,000 event capacity • Addressable sounder base compatibility • Control module delay timer • Automatic detector sensitivity testing (NFPA 72 compliant) • Automatic device type -code verification • Point trouble identification • Waterflow selection per module point • Alarm verification selection per detector point NOTIFIFER" by Honeywell • Maintenance alert warns when smoke detector dust accumula- tion is excessive • One -person audible or silent walk test with walk -test log and printout • System alarm verification selection per detector point • PAS (Positive Alarm Sequence) and Pre -signal per point (NFPA 72 compliant) • Up to 16 ANN-BUS annunciators- 8 per each ANN-Bus • Remote Acknowledge, Alarm Silence, Reset and Drill via addressable modules or remote annunciator • Upload/Download of program and data via USB with optional FS- Tools Programming Utility • Supports FlashScan& and CLIP protocols • SLC operates up to 10,000 ft. (3,000 m) in FlashScan mode with twisted, unshielded wire • Single addressable SLC loop which meets NFPA Class B and Class A requirements • 198 addressable device capacity (99 addressable detectors and 99 modules) • Compatible with NOTIFIER FireWarden and ONYX Series addressable devices (refer to the FireWarden SLC Wiring Man- ual) NOTIFICATION APPLIANCE CIRCUITS (NAGS) • Four independently programmable output circuits. Circuits can be configured for the following outputs: — Style Y (Class B) — Style Z (Class A) • Silence Inhibit and Autosilence timer options • Continuous, March Time, Temporal, or California code for main circuit board NACs with two -stage capability • Selectable strobe synchronization per NAC • 2,5 A special application, 250mA regulated, total power for NACs NOTE: Maximum or total 24VDC system power shared between all NAC circuits and the ANN-BUS is 2.7 A DN-60959:C • 7/16/2018 — Page 1 of 4 • Autoprogramming (learn mode) reduces installation time • Custom English labels (per point) may be manually entered or selected from an internal library file • Two programmable Form-C relay outputs • 99 software zones • Continuous fire protection during online programming • Program Check automatically catches common errors not linked to any zone or input point • OFFLINE PROGRAMMING: Create the entire program in your office using FS-Tools, a WindowsO-based software package, and upload/download system programming locally. Offline program- ming requires an ethernet connection. FS-Tools is available on www.ngtifier.com. 13=03=_ • Fire Alarm (red) • CO Alarm (red) • AC Power (green) • Supervisory (yellow) • Trouble (yellow) • Ground fault (yellow) • Battery fault (yellow) Disabled (yellow) • Maintenance (yellow) Communication (yellow) • Alarm Silenced (yellow) F1-F4 Programmable Function Keys (yellow) KEYPAD • 16 key alpha -numeric pad Acknowledge • Alarm Silence Drill (Manual Evacuate) • Four (4) programmable function keys - Reset (lamp test) PRODUCT LINE INFORMATION lllr�Addressable Fire Alarm Control Panel with one SLC loop. Includes main circuit board with display chassis with trans- former, backbox with door, plastic bag containing screws, cables, key, etc. FS-Tools: Programming software for Windows(@ -based PC com- puter. Available for download at www.notifier.com. CELL-CAB-N/CELL-MOD: Optional GSM communicators. IPOTS-COM: Dual technology (POTS and IP) communicator. (replacement board) DP-ES-R: Optional dress panel for the NFW-1 OOX (red). DP-ES-B: Optional dress panel for NFW-1 OOX (black). TR-CE-B: Optional trim ring for semi -flush mounting. (Black. For red, order TR-CE.) BB-XP: Optional cabinet for one or two modules. BB-25: Optional cabinet for up to six modules mounted on CHS-6 chassis. BB-26: Battery backbox, holds up to two 25 AH batteries and CHG- 75. NFS-LBB: Battery box, houses two 55 AH batteries CHS-6: Chassis, mounts up to six multi -modules in a BB-25 cabinet. CHG-75: Battery charger for lead -acid batteries with a rating of 25 to 75 AH, CHG-120: Remote battery charging system for lead -acid batteries with a rating of 55 to 120 AH. Requires additional NFS-LBB for mounting. NOTE: CHG- 120 or CHG-75 required for batteries larger than 18AH. BAT Series: Batteries, see data sheet DN-6933. PRN Series: UL listed compatible event printer. Uses tractor -fed paper. OPTIOITAL ITyODj!LF_q 4XTM Reverse Polarity Transmitter Module: Provides a sup Page 2 of 4 — DN-60959:C - 7/16/2018 vised output for local energy municipal box transmitter, alarm and trouble. Includes a disable switch and disable trouble LED. Power Expander Module: Optional power module. increases alarm power output to 6 amps. N-ANN-80: Remote LCD annunciator mimics the information dis- played on the FACP LCD display. Recommended wire type is un- shielded. (Basic model is black; order -W for white; see DN-7114.) N-ANN-10OR: Remote LCD annunciator mimics the information dis- played on the FACP LCD display. Recommended wire type is un- shielded. For use in FM applications only. (Basic model is black; order R for red.) N-ANN-110: LED Driver Module provides connections to a user sup- plied graphic annunciator. (See DN-7105.) N-ANN-LED: Annunciator Module provides three LEDs for each zone: Alarm, Trouble, and Supervisory. Ships with red enclosure. (See DN-60242J N-ANN-RLED: Provides alarm (red) indicators for up to 30 input zones or addressable points. (See DN-60242.) N-ANN-RLY: Relay Module provides 10 programmable Form-C relays. Can be mounted inside the cabinet. (See DN-7107.) N-ANN-SIPG: Serial/Parallel Printer Gateway module provides a connection for a serial or parallel printer. (See DN-7103.) FSP-951: Addressable low -profile photoelectric smoke detector. FlashScan only. FSP-951-IV: Addressable low -profile photoelectric smoke detector. Ivory. FlashScan and CLIP mode. NP-200: Addressable low -profile photoelectric smoke detector, 6300-6 base included, FlashScan only. NP-200-IV: Addressable low -profile photoelectric smoke detector. Ivory, B300-6-IV base included. FlashScan and CLIP mode- FSP-951T: Addressable low -profile photoelectric smoke detector with thermal sensor. FlashScan only. FSP-951T-IV: Addressable low -profile photoelectric smoke detector with thermal sensor, Ivory. FlashScan and CLIP mode. NP-20OT: Addressable low -profile photoelectric smoke detector with thermal sensor. B300-6 base included. FlashScan only. NP-200T-IV: Addressable low -profile photoelectric smoke detector with thermal sensor. Ivory, B300-6-IV base included. FlashScan and CLIP mode. FSP-951R: Remote test capable addressable photoelectric smoke detector for use with DNR(W) duct detector housing. FlashScan only. FSP-951R-IV: Remote test capable addressable photoelectric smoke detector for use with DNR(W) duct detector housing. Ivory. FlashScan and CLIP mode. NP-20OR: Remote test capable addressable photoelectric smoke detector for use with DNR(W) duct detector housing. FlashScan only. NP-20OR-IV: Remote test capable addressable photoelectric smoke detector for use with DNR(W) duct detector housing. Ivory, FlashS- can and CLIP mode. FST-951: Low -profile 135'F fixed thermal sensor. FlashScan only. FST-951 -IV: Low -profile 135°F fixed thermal sensor, Ivory. FlashS- can and CLIP mode. NH-200: Low -profile 135°F fixed thermal sensor. 8300-6 base included, FlashScan only. NH-200-IV: Low -profile 135°F fixed thermal sensor, Ivory. B300-6-IV base included, FlashScan and CLIP mode. FST-951R: Low -profile, intelligent, rate -of -rise thermal sensor. FlashScan only. FST-951R-IV: Low -profile, intelligent, rate -of -rise thermal sensor. Ivory. FlashScan and CLIP mode. NH-20OR: Low -profile 135°F fixed thermal sensor. B300-6 base included, FlashScan only. NH-200R4V: Low -profile 135°F fixed thermal sensor, Ivory. B300-6- IV base included, FlashScan and CLIP mode. FST-951H: Low -profile intelligent 190oF/88oC fixed thermal sensor. FlashScan only. FST-951H-IV: Low -profile intelligent 190oF/88oC fixed thermal sen- sor- Ivory. FlashScan and CLIP mode. NH-20OH: Low -profile intelligent 190'F/88'C fixed thermal sensor. B300-6 base included, FlashScan only. NH-20OH-IV: Low -profile intelligent 190'F/88*C fixed thermal sen- sor. Ivory. B300-6-IV base included, FlashScan and CLIP mode. Legacy Devices FSI-851: Addressable, low -profile ionization smoke detector. NI-1 it Addressable low -profile ionization smoke detector. FSP-851: Addressable low -profile photoelectric smoke detector. NP-100: Addressable low -profile photoelectric smoke detector. FSP-85IT: Addressable low -profile photoelectric smoke detector with thermal sensor. NP-10OT: Addressable low -profile photoelectric smoke detector with thermal sensor. FSP-851R: Remote test capable addressable photoelectric smoke detector for use with DNR(W) duct detector housing. NP-100R: Remote test capable addressable photoelectric smoke detector for use with DNR(W) duct detector housing. FST-851: Fast -response, low -profile heat detector. N H-1 00: Fast -response, low -profile heat detector. FST-851 R: Fast -response, low -profile heat detector with rate -of -rise option. NH-100R: Fast -response, low -profile heat detector with rate -of -rise option. FST-851 H: Fast -response, low -profile heat detector that activates at 190oF/88'C. NH-10OH: Fast -response, low -profile heat detector that activates at 190'F/88'C. FAPT-851: Addressable low -profile multi -sensor detector. NP-All 00: Addressable low -profile multi -sensor detector. B20OS: Programmable, addressable sounder base. B200SR: Addressable sounder base. DNR: InnovairFlex low -flow non -relay duct -detector housing. (Order FSP-851 R, FSP-951 R, or NP-1 OOR separately.) DNRW: InnovairFlex low -flow non -relay duct -detector housing, with NEMA-4 rating. Watertight. (Order FSP-851R, FSP-951R, or NP-10OR separately.) Addressable Afodules FMM-1: Addressable Monitor Module for one zone of normally -open dry -contact initiating devices. Mounts in standard 4.0" (10.16 cm.) box. Includes plastic cover plate and end -of -line resistor. Module may be configured for either a Style B (Class B) or Style D (Class A) IDC. NMM-100: Addressable Monitor Module for one zone of normally - open dry -contact initiating devices. Mounts in standard 4.0" (10.16 cm.) box. Includes plastic cover plate and end -of -line resistor. Mod- ule may be configured for either a Style B (Class B) or Style D (Class A) I DC. FDM-1: Dual Monitor Module. Same as NMM-100 except it provides two Style B (Class B) only IDCs. NDM-100: Dual Monitor Module. Same as NMM-100 except it pro- vides two Style B (Class B) only IDCs. FMM-101: Miniature version of NMM-100. Excludes LED and Style D option- Connects with wire pigtails. May mount in device backbox, NMM-10OP: Miniature version of NMM-100, Excludes LED and Style D option. Connects with wire pigtails. May mount in device backbox. FZM-1: Similar to NMM-100. Addressable Monitor Module for one zone of conventional two -wire detectors. Requires resettable 24 VDC power. Refer to the Device Compatibility Document for listed compatible devices and quantity limitation. NZM-100: Similar to NMM-100. Addressable Monitor Module for one zone of conventional two -wire detectors. Requires resettable 24 VDC power. Refer to the Device Compatibility Document for listed compatible devices and quantity limitation. FCM-1: Addressable Control Module for one Style Y/Z (Class B/A) zone of supervised polarized Notification Appliances. Mounts directly to a 4.0" (10,16 cm.) electrical box. NAC option requires external 24 VDC to power notification appliances. NC-100: Addressable Control Module for one Style Y/Z (Class B/A) zone of supervised polarized Notification Appliances. Mounts directly to a 4.0" (10.16 cm.) electrical box. NAC option requires external 24 VDC to power notification appliances. FIRMA: Addressable relay module containing two isolated sets of Form-C contacts, which operate as a DPDT switch. Mounts directly to a 4.0" (10.16 cm.) box, surface mount using the SM13500. NC-10OR: Addressable relay module containing two isolated sets of Form-C contacts, which operate as a DPDT switch. Mounts directly to a 4.0" (10.16 cm.) box, surface mount using the SMB500, NBG-12LX: Addressable manual pull station with interface module mounted inside. NOT-BG12LX: Addressable manual pull station with interface mod- ule mounted inside. ISO-X: Fault Isolator Module. k1k ISO-6: Six -fault isolator module. Mount one or two modules in a BB- XP cabinet (optional). Mount up to six modules on a CHS-6 chassis in a CAB-3/CAB-4 series cabinet. SMB500: Used to mount all modules except the FMM-101/NMM- 1 OOP. N MM-1 00-10: Ten -input monitor module. Mount one or two modules in a BB-2F cabinet (optional). Mount up to six modules on a CHS-6 chassis in a BB-6F cabinet. NZM-100-6: Six -zone interface module. Mount one or two modules in a BB-XP cabinet (optional). Mount up to six modules on a CHS-6 chassis in a CAB-3/CAB-4 series cabinet, SWIFr Wireless Devices FWSG: Wireless Gateway FWD-20OP: intelligent, wireless photo detector. FWH-200ROR1 35: LiteSpeed intelligent wireless rate of rise (135') heat detector. FWD-200ACCLIMATE: Wireless Acclimate Detector FWH-200FIX1 35: intelligent wireless fixed -temperature (135') heat detector, FW-MM: Intelligent wireless monitor module. FW-RM: Intelligent wireless relay module. NBG-1 2LW: Intelligent wireless pull station. WAV-RL, WAV-WL,WAV-CRL,WAV-CWL: Intelligent AV bases. W-USB: Wireless USB radio/antenna dongle that plugs into the USB port of a PC running SWIFT Tools. SWIFT Tools: Programming and diagnostic utility for the Wireless Gateway and devices. Available for download from firelite.com. NOTE: For more information on Compatible Addressable Devices for use with the Fire Warden- 1 OOX, see the following data sheets (document numbers). NP-200 Series (DN-60979), NH-200 Series (DN-60980), FSP-851 Series (DN-6935), FSP-951 Series (DN-60977), FST-851 Series (DN-6936), FST-951 Series (DN-60975), FAPT-851 (DN-6937), N 1 00-ISO (DN-6994), NP- 100 series (DN-6995), NH- I 001NH- I OOR (DN- 6997), DNRlInnovairFlex (DN-60424, DN-60429), NP-A100 (DN-6998), NMM-I00INMM-I00PINDM-I00INZM-100 (DN-6999), NC-100 (DN- 7000), NC-10OR (DN-60383), NMM-100-10 (DN-6990), MM-11FDM-11 FZM-11FMM-101 (DN-6720), FCM-11FRM-1 (DN-6724), NOT-BG12LX (DN-7001), NBG-12LX (DN-6726), and FireWarden SLC Manual (52304). DN-60959:C • 7/16/2018 — Page 3 of 4 MZNRMA�,� • Intelligent Signaling Line Circuits., ........ ......... _ .... _ 1 • Addressable device capacity..................................................198 • Programmable software zones.................................................99 • Annunciators.............................................................................16 Electrical Specifications AC Power: Operates in either 120 or 240 VAC, 50/60 Hz, 3.25 A, auto -sensing- no switch required. Wire size: minimum 14 AWG (2.00 mm2) with 600 V insulation. Nonpower-limited, supervised. Battery: Two 12 V 18 AH lead -acid batteries. Battery Charger Capacity: 7-18 AH (FireWarden-100X cabinet holds maximum of two 18 AH batteries.) Communication Loop: Supervised and power -limited - Notification Appliance Circuits: Terminal Block provides connec- tions for four NACs, Style Y (Class B) or Style Z (Class A). Special Application power. Power -limited, supervised circuitry. Maximum signaling current per circuit: 2.5 amps special application, 250mA regulated. End -of -Line Resistor: 4.7k ohm, '/2 watt (P/N 71252 UL listed) for Style Y (Class B) NAC; system capable of 1.9 ko - 22 kn ELR range. Refer to the NOTIFIER Device Compatibility Document for listed compatible devices. Two Programmable Relays and One Fixed Trouble Relay: Con- tact rating: 2.0 A @ 30 VDC (resistive), 0.5 A @ 30 VAC (resistive). Form-C relays, non -power -limited, non -supervised. Cabinet Specifications Door: 19.26" (48.92 cm.) high x 16.82" (42.73 cm.) wide x 0.72" (1.82 cm.) deep. Backbox: 19.00" (48.26 cm.) high x 16.65" (42.29 cm.) wide x 5.25" (13.34 cm.) deep. Trim Ring (TR-CE/B): 22.00" (55.88 cm.) high x 19.65" (49.91 cm.) wide. Shipping r •` • •--♦ Temperature and Humidity Ranges This system meets NFPA requirements for operation at 0 — 49°C/32 — 120°F and at a relative humidity 93% ± 2% RH (noncondensing) at 32°C ± 2°C (90oF ± 3°F). However, the useful life of the system's standby batteries and the electronic components may be adversely affected by extreme temperature ranges and humidity. Therefore, it is recommended that this system and its peripherals be installed in an environment with a normal room temperature of 15 — 27°C/60 — 80°F. End -of -Line Resistor Assembly (R-47K and R-3.9K): The 47k ohm assembly supervises the NMM-100-10, NDM-100, NMM- 100P, and NC-100 module circuits. The 3.9k ohm assembly super- vises the NZM-100-6 module circuit. These resistors are included with each module. Power Supervision Relay: Supervises the power to 4-wire smoke detectors and notification appliances. Wiring a dire ents While shielded wire is not required, it is recommended that all SLC wiring be twisted -pair to minimize the effects of electrical interfer- ence. Refer to the panel manual for wiring details. NFPA Standards The FireWarden-100X complies with the following NFPA 72 Fire Alarm Systems requirements: — LOCAL (Automatic, Manual, Waterflow and Sprinkler Supervi- sory). — AUXILIARY (Automatic, Manual and Waterflow) (requires 4XTM). — REMOTE STATION (Automatic, Manual and Waterflow) (Where a DACT is not accepted, the alarm, trouble and supervi- sory relays may be connected to UL 864 listed transmitters. For reverse polarity signaling of alarm and trouble, 4XTM is required.) — PROPRIETARY (Automatic, Manual and Waterflow). — CENTRAL STATION (Automatic, Manual and Waterflow, and Sprinkler Supervised). — OT, PSDN (Other Technologies, Packet -switched Data Net- work) — IBC 2012, IBC 2009, IBC 2006, IBC 2003, IBC 2000 (Seismic). — CBC 2007 (Seismic) The listings and approvals below apply to the basic FireWarden- 100X control panel. In some cases, certain modules may not be listed by certain approval agencies, or listing may be in process. Consult factory for latest listing status. ENCItAEAING I MANUEACTU QUAEITY SYSTEMS This document is not intended to be used for instafiation purposes. We try to keep our product information up-to-date and accurate. We cannot cover aft specific applications or anticipate atl requirements. All specifications are subject to change without notice. AlarmNet®, NOTIFIERO, FireWarden®, SWIFT?, and System Sensor ® NOTIFIER are registered trademarks of Honeywell International Inc. Microsoft® and 12 Clintonville Road Windows® are registered trademarks ofthe Microsoft Corporation. Northford, CT 06472 ©2018 by Honeywell International Inc All rights reserved_ Unauthorized 203,484.7161 use of this document is strictly prohibHed- www.notifier.com Country of Origin: USA by Honeywell The N-ANN-80 annunciator is a compact, backlit, 80-character LCID fire annunciator that mimics the Fire Alarm Control Panel (FACP) display. It provides system status indicators for AC Power, Alarm, Trouble, Supervisory, and Alarm Silenced conditions. The N-ANN- 80 and the FACP communicate over a two -wire serial interface employing the ANN-Bus communication format. Connected devices are powered, via two additional wires, by either the host FACP or a remote UL-listed, filtered power supply. The N-ANN-80 is black; for white order N-ANN-80-W. The N-ANN-80 displays English -language text of system point infor- mation including device type, zone, independent point alarm, trouble or supervisory status, as well as any custom alpha labels pro- grammed into the control panel. It includes control switches for remote control of critical system functions, (A keyswitch prevents unauthorized operation of the control switches.) Up to eight N-ANN-80s may be connected to the ANN-Bus of each FACP. Minimal programming is required, which saves time during system commissioning. The N-ANN-80 is compatible with NOTI- FIER FACPs with an ANN-Bus, such as the NFW-50X. • Listed to UL Standard 864, 9th Edition • Backlit 80-character LCD display (20 characters x 4 lines) • Mimics all display information from the host panel • Control switches for System Acknowledge, Signal Silence, Drill, and Reset • Control switches can be independently enabled or disabled at the FACP • Keyswitch enables/disables control switches and mechanically locks annunciator enclosure • Keyswitch can be enabled or disabled at the FACP • Enclosure supervised for tamper • System status LEDs for AC Power, Alarm, Trouble, Supervisory, and Alarm Silence • Local sounder can be enabled or disabled at the FACP • N-ANN-80 connects to the ANN-Bus terminal on the FACP and requires minimal panel programming • Displays device type identifiers, individual point alarm, trouble, supervisory, zone, and custom alpha labels • Time -and date display field • Surface mount directly to wall or to single, double, or 4" square electrical box • Semi -flush mount to single, double, or 4" square electrical box. Use ANN-SB80KIT for angled view mounting • Can be remotely located up to 6,000 feet (1,800 m) from the panel • Backlight turns off during AC loss to conserve battery power but will turn back on if an alarm condition occurs • May be powered by 24 VDC from the host FACP or by remote power supply (requires 24 VDC) • Up to eight N-ANN-80s can be connected on the ANN-Bus Controls and Indicators • AC Power • Alarm NOTIFIER A by Honeywell • Trouble • Supervisory • Alarm Silenced • Operating voltage range: 18 VDC to 28 VDC • Current consumption @ 24 VDC nominal (filtered and non- resettable): 40 mA maximum • Ambient temperature: 32°F to 120°F (0°C to 49°C) • Relative humidity: 93% ± 2% RH (non -condensing) at 32°C 2°C (90°F ± 3°F) • 5.375" (13.65 cm.) high x 6.875" (17,46 cm.) wide x 1 .375" (3,49 cm.) deep • For use indoors in a dry location • All connections are power -limited and supervised The ANN-Bus POWERING THE DEVICES ON THE ANN-BUS FROM AUXIL- IARY POWER SUPPLY` The ANN-Bus can be powered by an auxiliary power supply when the maximum number of ANN-Bus devices exceeds the ANN-Bus power requirements- See the FACP manual for more information. ANN-BUS DEVICE ADDRESSING Each ANN-Bus device requires a unique address (ID Number) in order to communicate with the FACP. A maximum of 8 devices can be connected to the FACP ANN-Bus communication circuit. See the FACP manual for more information. WIRE REQUIREMENTS: COMMUNICATIONS CIRCUIT The N-ANN-80 connects to the FACP ANN-Bus communications cir- cuit. To determine the type of wire and the maximum wiring distance that can be used with FACP ANN-Bus accessory modules, it is nec- essary to calculate the total worst case current draw for all modules on a single 4-conductor bus. The total worst case current draw is calculated by adding the individual worst case currents for each module. DN-7114:D • 3/15/2018 — Page 1 of 2 NOTE: For total worst case current draw on a single ANN-Bus refer to appropriate FACP manual. WIRE REQUIREMENTS: POWER CIRCUIT • 14 to 18 AWG {0.75 - 2.08 ml wire for 24 VDC power circuit is acceptable. • All connections are power -limited and supervised. • A maximum of eight N-ANN-80 modules may be connected to this circuit. Ordering Options: Black 80 character LCD Annunciator. N-ANN-80-W: White, 80 character LCD Annunciator, ANN-SB80KIT-B: Black surface mount backbox with angled wedge. ANN-SB80KIT-W: White surface mount backbox with angled wedge. The listings and approvals below apply to the N-ANN-80. In some cases, certain modules may not be listed by certain approval agen- cies, or listing may be in process. Consult factory for latest listing status. FM approved i. Efl51RON A MAN®FACTAAIMI QUALITY SYSTEMS This document is not intended to be used for installation purposes_ We try to keep our product information up-to-date and accurate. We cannot cover aft specific applications or anticipate all requirements. N OTC F I E R Al] specifications are subject to change without notice. 12 Clintonville Road NCTIFIERO is a registered trademark of Honeywell International Inc. Northford, CT 06472 02018 by Honeywell International Inc. All rights reserved. Unauthorized 203.484,7161 use of this document is strictly prohibited. www,notifier.com Country of Origin. USA 0 byHoneywell ~ Universal full event sole & dual path cellular Vor|Pcommercial fire alarm reporting from any panel brand, virtually anywhere nationwide Code-cwmpUant,replaces 2POTslines per FACPsaves thousands ofdollars per year over the leased land||nes Supports 12V-24Vcontrol panels and FACPsthat communicate using Contact |Dand 4/2(such asonlegacy pands).asprimary orbackup Full data Reporting to any Central Station nationwide, via choice �LT������V��n=���� rommuni��cdd�|U� and safety alarm reports on LTE(Long Term Evolution) 1O+year life, cyber- ttdmnu|d'bU|iondnUarceUula,network'for maximum life safety & liability protection. °Proven to work even where other's won't - using Signal BooStTM & twin dual diversity antennas - Max, signal acquisition & null avoidance (receives signals simultaneously on both antennas) ° Easiest imgaUeUon, powered by panel, NO extra power supply, NOextra conduit. (Excludes oircccAspowcred "-Ps^models, with transformer updon.)t ~ Dual Path CeUuia,/|P Models Save Time &WYuney Uniquely including 4programmable EOLyzone inputs; 2Form [ Relay outputs (no extra supervision modules to buy or|nsta|V; plus, 2Telephone- style ]acksforrasy FAcP'connection.Self-supervised on4wires. • Preactivated to ensure communications -saves time and labor onsite ° LED Status /TroubleIndicators 3 Radio Status LED Indicators (visible from outside standard model housing) Green, Signal Strength; Amber- Busy/Activation; Red -Trouble (4 additional LEDs, not visible, for network status & troubleshooting). Power LED indicator viewable nnouter metal enclosure models. ° Over-the-AirV d ble Communicator Firrnware. Remote ability for critical/mandatory updates, without atruck-roll ° Cost -saving models and plans for any code requirement. Dramatic savings over monthly dedicated |andUnccharges. VLand NFPA72 Fire StadjnkSeries Wireless Commercial Fire Alarm Sole Path & Dual Path Communicators provide universal support for any brand 1ZVtoZ4Vfire alarm control panel, reporting inContact !Dand 4/2. With broadest LTEcoverage footprint, Verizon orAT&T,using proven StarLinkcircuitry, they are also available inlocking metal models. All provide the most economical solution for easy, versatile installation. Also regional compliances, i.e,[SFK0'NY[FD'LAFDand more. Easy, Universal Installation mt Every Application; Panel - Powered Technologr. easily connected to any panel or Fire Alarm Control Panel in any application, StarLink Fire also comes in standard, or models in metal housings, with code -compliant supervision, and choice of power options, Panel -Powered Technology" (powered by the panel), or direct -connect 120VAC models. Signal Boost circuitry & dual diversity antennae for maximum signal acquisition & null avoidance, receiving signals simultaneously onboth antennae. Flexible Performance & Reporting Options. StarUnkRre provides full data reporting, insole and dual path, asa primary nrbackup, uzany central station ofyour choice, without requiring any special equipment nnpremises. Ultra -affordable plans are available tomeet various codes and requirements, with supervisory check -ins from 2O0 seconds, to5minutes; and/or from 1tn6hours. The units are very easily activated, plans and options are selected, and 24/7account management isprovided all through wwwoapcncnmncccnm. Napco Starl-ink Universal Fire Alarm Communicators ^ Sole Path Cellular and Dual Path Cellular &/or|P Models ° Choice ofLTE Networks, veriznnorAT&T models ~ Choice ofplans (varies bymodel) check -ins from 200 seconds unS'minutes'and from lhour; upm0hours for dual path ^ Patented Signal Boost' and Dual Diversity Antennae for maximum signal acquisition & null avoidance, receiving signals simultaneously onboth antennae ° Money -saving T,adeupincentive credit for security professionals, onnew orretrofit fire systems, ie,tradeup missing/retired pOTslines, old radios & networks urnew installations ~ Bonus: Full High -Speed mapcoPanel remote uploading/ downloading ~ COMPLIANCES: wFp*72Editions: 2019'2O18'20l3'2O1O' 2007;UL8e4.10chEd,ou610'uL985.uL1023.NY[FD; connected by go on connected Ordering noy one AT&T Uni ue0nboard Other !TE WiFi 9 Electrical Input Network Cell IR Option Labor/Cost-Savor patings Inputs Input Ratings Outputs Output Ratings Sul Features (opt DUALPATN 2TelCojacksforEZ Panel Powered Tech'y:'` ( OUTI,OUT2:Dry Contact, Form SLE-LTEAI•CFB AT&T Yes Yes Yes FACP Connect; 4 IN I: 9 25VDC Max nputVoltage1025VDC: CRelay, 30VAC/DC,500mA Pro raputs;2 EOLR N1,IN2, input OUT1, 9 nputCurrent:1b2mA p Max sMax3Open when active, ---- zone inputs; 2 Forr I m C IN3, IN4, IN2,IN3,IN$1N5- OOT2, to 100mAstandby; Outputs Max3> when active, Relay outputs(avoids INS 9-25VDCMaxinput PGM3 300mA peak during Max 2SVwheti active. Max 5lELTEVhCFB Verizon Yes Yes Yes metforsupervislon current1.2mA module) transmissions current24mA@2SV 2TelCojacks torE � �� OUT1,OUT2.DryContact, Form SLE-LTEAI-CFBPS AT&T ) Yes Yes Yes FACP Connect; 4 Direct AC -Powered: Input IN1:4-25VDCMax C Relay, 30VAC/DC, 500mA Transformer Programmable FOUR Voltage: 120VAC nominal IN1,IN2, ( input current2mA OUT1, Max PGM3: Open Collector (TRF12 --= � zone inputs; 2 Form C Input Current:200mA IN31 IN4, IN2,IN3,IN4JN5: OUT21 Outputs Max3Vwhenadive, 16VAC, OVA Relay outputs (avoids max; maxnnum charging N5 ( 9r25UDC Max input PGM3 Max 25Vu1henactive. Max transformer) SLE-LTEVI-CFBPS Verizon Yes Yes Yes pact for supervision current:200mA curre)nt1.2mA current 24mA@ 25V module) ACCESSORIES: SLE-WIFI-MODULE Optionally connects supported dual path models to Internet via WiEI, eliminating Ethernet cable connection. Requires 7AH batty. ("See details WI2191) SLE-ANTEXT75 Optional extended range omni, antenna w/ 75' cable, premium low -loss cable & full mounting hardware & ground fault isolation mounting plate SLE-ANTEXT50 As above, with 50' cable SLE-ANTEXT30 As above, with 30' cable TRF12 Optional Plug in AC Transformer, 16.5V / 20VA (use is subject to local code compliance)t Free Commercial Fire LTETradeup Trifold" Brochures / Moders/Stuffers (A747) AStamiink Fire. 333 Bayview Ave., Amityville, NY 11701 , 1-800-645-9445 - www.napcosecurity.com Noe: Always mnailt ted viral manual and/or ARj eor compliance regwremeeb `or your arevappllication. Starter, Stamnk re 71reGAk, Si„i alBoost, Pane! Powered Technology Gernim& Gemini Commercial are trademarkso` Napco, AW vernnr, LTC, etc, are trademarks ,i.,rresc"r ,m1,,n_ S'ar�.nkc rr,IlCoia<ovea,e,LSirwr,t,all-sl!par barrcre.,cm r,rilDnr1r11 rr_gilae_ppwrr.cas:rere.� JorsteaACI"Add40irisjrt'iarrrn,nSaicbI ry r,grir_=mrr -Wnerepersi,rc7 c,AH); regaiI wduiLor it S_Cailsor hr SriirktraCr�p cer,tivePePink.snderht.phn.h irapms_„ri/-coy. ls, rl rxK ;'hrk4gt,i a„c s�: uo,ea'otharg�4v/cor,or noc.e li, I`e spar d. r-a e'oa>'wr ;neat Carriers. CFO^2i0 9A rC qcoir, n rl ,, !e NArDAG NSSr) 75I1, D19.8 enables installation in a variety of locations, The DTK- 120HWLOK includes an NFPA 72 2013 10.6.5.2 compatible lockout kit to prevent accidental disconnect *POO of the fire alarm system. • Approved for 20A circuit breakers • Diagnostic LED indicates ground presence, system power and SPID function use in harsh environments Complies with ANSI/IEEE C62.41 and C62,45 Category 6 standards fire alarm system ----------------- Applications • Fire Alarm Control Panels • Equipment Panel • Dedicated Branch Circuit Accessories ® DIN Rail Mounting Kit — DTK-DRK I ------------------------------- Dimensions 078 2111111MIll 00,18 Mechanical Characteristics I/," NPT Parallel Wired NEMA4X -31 -F - 104°F (-35°C - 40°C) 95% non -condensing 3.5"L x 1.89"W x 3.4" H 38.9mm x 48.3mm x 86.4mm 0.551b (25 kg) Quality, Standards & Approval AgencyApprovols: UL 1449 411 Edition, cUL SPD Type* Type 1 SPD 'Warranty: Ten Year Limited Every precaution has been taken to ensure that this literature is accurate and complete. DITEK corporation assumes no responsibility and disclaims all liability for damages resulting from the use of this Information or for any errors or omissions. One DITEK Center 1720 Starkey Road - Largo, FL 33771 Doc. Number: SPS-100057-005 Rev 3 10/17 MAUJt IN Phone: 1-800-753-2345 Direct: 727-812-5000 02017 DITEK Corp. us Technical Support: 1-888-472-6100 Page 1 of 1 C@ www.diteksurgeprotection.com I LISTED The NOTIFIER® FSP-951 Series intelligent plug-in smoke detectors are designed for both performance and aesthetics, and are direct replacements for the FSP-851 Series. A new modern, sleek, con- temporary design and enhanced optical sensing chamber is engi- neered to sense smoke produced by a wide range of combustion sources in accordance with more stringent code standards. The FSP-951 Series detector sensitivity can be programmed in the control panel software. Sensitivity is continuously monitored and reported to the panel. Point ID capability allows each detector's address to be set with rotary, decimal address switches, providing exact detector location for selective maintenance when chamber contamination reaches an unacceptable level. Dual electronic thermistors add 135'F (57'C) fixed temperature thermal sensing on the FSP-951 T. The FSP-951 R is a remote test capable detector for use with DNR Series duct detector housings. FSP-951 series detec- tors are available for both FlashScan@ and CLIP applications as designated. SLC LOOP: . Two -wire SLC loop connection • Unit uses base for wiring • Compatible with FlashScan@ and CLIP protocol systems • Stable communication technique with noise immunity ADDRESSING: . Addressable by devil Rotary, decimal addressing (Refer to the NOTIFIER panel manuals for device capacity.) • Sleek, low -profile, stylish design • Unique single -source design to respond quickly and dependably to a broad range of fires • Integral communications and built-in device -type identification • Built-in tamper resistant feature • Remote test feature from the panel • Walk test with address display (an address on 121 will blink the detector LED: 12-[pause]-1 (FlashScan systems only) • Built-in functional test switch activated by external magnet • Removable cover and insect -resistant screen for simple field cleaning • Expanded color options OPERATION: • Designed to meet UL 268 7th Edition • Factory preset at 1.5% nominal sensitivity for panel alarm thresh- old level • LED "blinks" when the unit is polled (communicating with the fire panel) and latches in alarm. • Low standby current MECHANICALS: • Sealed against back pressure • SEMS screws for wiring of the separate base • Designed for direct -surface or electrical -box mounting • Plugs into separate base for ease of installation and maintenance NOTIFIER by Honeywell • Separate base allows interchange of photoelectric, ionization and thermal sensors OPTIONS: . Optional relay, isolator, and sounder bases Ti • �, FSP-951 Series plug-in intelligent smoke detectors use a detach- able base to simplify installation, service and maintenance. Installa- tion instructions are shipped with each detector. Mount detector base (all base types) on an electrical backbox which is at least 1.5" (3.81 cm) deep. For a chart of compatible junction boxes, see DN-60054. NOTE: Because of the inherent supervision provided by the SLC loop, end -of -line resistors are not required. Wiring 7-taps" or branches are permitted for Style 4 (Class "B') wiring only. When using relay or sounder bases, consult the ISO-X(A) installation sheet 156-1380 for device limitations between isolator modules and iso- lator bases. Construction These detectors are constructed of fire-resistant plastic. The FSP- 951 Series plug-in intelligent smoke detectors are designed to com- mercial standards and offer an attractive appearance. Each FSP-951 Series detector uses one of the panel's addresses (total limit is panel dependent) on the NOTIFIER Signaling Line Cir- cuit (SLC). It responds to regular polls from the control panel and reports its type and the status. If it receives a test command from the panel (or a local magnet test), it stimulates its electronics and reports an alarm. It blinks its LEDs when polled and turns the LEDs on when commanded by the panel. The FSP-951 Series offers fea- tures and performance that represent the latest in smoke detector technology. DN-60977:B - 7/1/2019 — Page 1 of 3 Product Line Information NOTE: "-IV" suffix indicates CLIP and FlashScan device. FSP-951: White, low -profile intelligent photoelectric sensor, FlashS- can only FSP-951A: Same as FSP-951 but with ULC listing Ivory, low -profile intelligent photoelectric sensor FSP-951A-IV: Same as FSP-951 -IV but with ULC listing FSP-951T: White, same as FSP-951 but includes a built-in 135°F (57°C) fixed -temperature thermal device, FlashScan only FSP-951TA: Same as FSP-951T but with ULC listing FSP-951T-IV: Ivory, same as FSP-951T but includes a built-in 135°F (57°C) fixed -temperature thermal device FSP-951TA-IV: Same as FSP-951T-IV but with ULC listing FSP-95IR: White, low -profile intelligent photoelectric sensor, remote test capable, for use with DNR/DNRW, FlashScan only FSP-951 RA: Same as FSP-951 R but with ULC listing, for use with DNRA FSP-95IR-IV: Ivory, low -profile intelligent photoelectric sensor, remote test capable, for use with DNR/DNRW FSP-951 RA -IV: Same as FSP-951 R-IV but with ULC listing, for use with DNRA INTELLIGENT BASES NOTE: For details on intelligent bases, see DN-60981. B300-6: White, 6" base, standard flanged low -profile mounting base (CSFM.- 7300-1653:0109) Ivory,6" base, standard flanged low -profile mounting base (CSFM.- 7300-1653:0109) B300A-6: Same as B300-6, ULC listed B30OA-6-IV: Ivory, 6" standard flanged low -profile mounting base, ULC listed B300-6-BP: Bulk pack of B300-6, package contains 10 B501-WHITE: White, 4" standard European flangeless mounting base. UL/ULC listed (CSFM: 7300-1653:0109) B501-BL: Black, 4" standard European flangeless mounting base. UL/ULC listed (CSFM.- 7300-1653:0109) B501-IV: Ivory color, 4" standard European flangeless mounting base. UL/ULC listed (CSFM: 7300-1653:0109) B501-WHITE-BP: Bulk pack of B501-WHITE contains 10 B224RB-WH: White, relay base (CSFM.- 7300-1653:0216) B224RB-IV: Ivory, relay base (CSFM.- 7300-1653:0216) B224RBA-WH: White, relay base, ULC listing B224RBA-IV: Ivory, relay base, ULC listing 13224BI-WH: White, isolator detector base (CSFM: 7300-1653:0216) B224BI-IV: Ivory isolator detector base (CSFM: 7300-1653:0216) B224BIA-WH: White, isolator detector base, ULC listing B224BIA-IV: Ivory isolator detector base, ULC listing B20OS-WH: White, Intelligent addressable sounder base capable of producing sound output in high or low volume with ANSI Temporal 3, ANSI Temporal 4, continuous tone, marching tone, and custom tone. Uses FlashScan protocol. (CSFM: 7300-1653:0213) B20OS-IV: Ivory, Intelligent addressable sounder base capable of producing sound output in high or low volume with ANSI Temporal 3, ANSI Temporal 4, continuous tone, marching tone, and custom tone. Uses FlashScan protocol. (CSFM.- 7300-1653:0213) B200SA-WH: Same as B200S-WH, ULC listing Page 2 of 3 — DN-6097TB • 711/2019 B200SCOA-WH: White, Intelligent, programmable sounder base in English/French (required in Canada for ULC applications with GO Series detector applications B200SCOA-IV: Ivory Intelligent, programmable sounder base in English/French (required in Canada for ULC applications with CO Series detector applications, ULC listing B20OS-LF-WH: White, Low Frequency Intelligent, programmable sounder base. Produces a fundamental frequency of 520 Hz +/- 10% with a square wave or its equivalent; designed to meet the NFPA 72 sleeping space requirement. (CSFM.- 7300-1653:0238) B200S-LF4V: Ivory, Low Frequency Intelligent, programmable sounder base. Produces a fundamental frequency of 520 Hz +/- 10% with a square wave or its equivalent; designed to meet the NFPA 72 sleeping space requirement. (CSFM.- 7300-1653:0238) B200SR-WH: White, Intelligent sounder base capable of producing sound output with ANSI Temporal 3 or continuous tone. Intended for retrofit applications. (CSFM.- 7300-1653:0213) B200SR-IV: Ivory, Intelligent sounder base capable of producing sound output with ANSI Temporal 3 or continuous tone. Intended for retrofit applications. (CSFM: 7300-1653:0213) B200SRA-WH: Same as B200SR-WH with, ULC listing B200SRA-IV: Same as B200SR-IV in Ivory color, ULC listing B200SR-LF-WH: White, Low Frequency Intelligent, programmable sounder base. Produces a fundamental frequency of 520 Hz +/- 10% with a square wave or its equivalent; designed to meet the NFPA 72 sleeping space requirement. Intended for retrofit applica- tions. (CSFM: 7300-1653:0238) B200SR-LF-IV: Ivory, Low Frequency Intelligent, programmable sounder base. Produces a fundamental frequency of 520 Hz +/- 10% with a square wave or its equivalent; designed to meet the NFPA 72 sleeping space requirement. Intended for retrofit applica- tions. (CSFM.- 7300-1653:0238) rlr TR300: White, replacement flange for B21 OLP(A) base TR300-IV: Ivory, replacement flange for B21 OLP(A) base RA100Z(A): Remote LED annunciator, 3-32 VDC. Mounts to a U.S. single -gang electrical box. For use with B501 (A) and 6300-6(A). M02-04-00: Test magnet M02-09-00: Test magnet with telescoping handle CK300: Color Kit (includes cover and trim ring), white, 10-pack CK300-IV: Color Kit (includes cover and trim ring), ivory, 10-pack CK300-BL: Color Kit (includes cover and trim ring), black, 10-pack MMUNIKOBIMMI Sensitivity: • UL Applications: 0.5% to 4.0% per foot obscuration. • ULC Applications: 0.5% to 3.5% per foot obscuration Size: 2.0" (5.3 cm) high; base determines diameter — B300-6: 6.1 " (15.6 cm) diameter — B501: 4" (10.2 cm) diameter For a complete list of detector bases see DN-60981 Shipping weight: 3.4 oz. (95 g) Operating temperature range: • FSP-951: 32°F to 122°F (0°C to 50°C) • FSP-951T Series: 32°F to 1 OOoF(OoC to 38°C) • FSP-951R Series installed in a DNR/DNRW, -4'Fto 158°F (-20°C to 70°C) UL/ULC Listed Velocity Range: 0-4000 fUmin. (1219.2 m/min.), suitable for installation in ducts Relative humidity: 10% — 93% non -condensing Thermal ratings: fixed -temperature set point 135°F (57'C), rate -of - rise detection 15°F (8.3°C) per minute, high temperature heat 190°F (88°C) ELECTRICAL SPECIFICATIONS Voltage range: 15 - 32 volts DC peak Standby current (max. avg.): 200pA @ 24 VDC (one communica- tion every 5 seconds with LED enabled) Max current: 4.5 mA @ 24 VDC ("ON") DETECTOR SPACING AND APPLICATIONS NOTIFIER recommends spacing detectors in compliance with NFPA 72. In low airflow applications with smooth ceiling, space detectors 30 feet (9.1 m). For specific information regarding detector spacing, placement, and special applications refer to NFPA 72. A System Smoke Detector Application Guide, document A05-1003, is avail- able at www.systemsensor.com. NOTIFIER 12 Clintonville Road Northford, CT 06472 203.484.7161 www.notifier.com a - . 0 . . 0 0 Listings and approvals below apply to the FSP-951 Series detectors. In some cases, certain modules may not be listed by certain approval agencies, or listing may be in process. Consult factory for latest listing status. • UL/ULC Listing: S1115 • FM Approved • CSFM: 7272-0028:0503 This document is not intended to be used for installation purposes We try to keep our product information up-toAafie and accurate We cannot cover all specific applications or anticipate all requirements All specifications are subject to change without notice ,"a-0 ,0- " EEC, a—, S�Ste- senscl,, a,e egoore, Country of Origin Mexico NOT I F 11WEE R by Honeywell I I]Tk 111� , " I Mll'i'l�,''�ll�ll,�i'lli7froll OMUTA in ME Me 2 0 The Notifier DNR(A) intelligent non -relay photoelectric duct smoke detector and DNRW watertight non -relay photoelectric duct smoke detector feature a pivoting housing that fits both square and rectan- gular footprints capable of mounting to a round or rectangular duct. The DNRW duct smoke detector, with its NEMA-4 rating, is listed as a watertight, UV resistant enclosure providing protection against fall- ing dirt, rain, and windblown dust, splashing and hose directed water, allowing operators to use the detector in the most extreme environments. These units sense smoke in the most challenging conditions, oper- ating in airflow speeds of 100 to 4,000 feet per minute (0.5 — 20.32 m/s), temperatures of -4°F — 158°F (-20oC — 70oC), and a humidity range of 0 — 95 percent (non -condensing.) An improved cover design isolates the sensor head, which allows for ease of maintenance. A cover tamper feature indicates a trouble sig- nal for a removed or improperly installed sensor cover. The housing provides a 3/4-inch conduit knockout and ample space to facilitate easy wiring and mounting of a relay module. The Notifier DNR(A) duct smoke detectors can be customized to meet local codes and specifications without additional wiring and are compatible with all previous models, including remote test accesso- ries. I • Photoelectric, integrated low -flow technology • Air velocity rating from 100 ft/min — 4,000 ft/min (0.5 m/s — 20.32 m/s) Versatile mounting options: square or rectangular configuration • Broad ranges for operating temperature (-4°F — 158°F, -20°C — 70'C) and humidity (0% — 95% non -condensing) • Patented sampling tube installs from front or back of the detector with no tools required • Cover tamper signal • Increased wiring space with a newly added 3/4" conduit knockout Available space within housing to accommodate mounting of a relay module Easily accessible code wheels on sensor head (sold separately) • Clear cover for convenient visual inspection Remote testing capability • Requires com line power only • Accommodates an addressable relay module, sold separately, (FRIM-1) for applications requiring a Form-C relay Specif ications Size: (Rectangle) 14.38 in (37 cm) Length; 5 in (12.7 cm) Width, 2.5 in (6.6 cm) Depth Size: (Square) 7.75 in (19.7 cm) Length; 9 in (22.9 cm) Width; 2.5 in (6.35 cm) Depth Weight: 1.6 lb (0.73 kg) Operating Temperature Range: -4°F — 158°F (-20°C — 70°C) Storage Temperature Range: -22°F — 158°F (-30°C — 70'C) Operating Humidity Range: 0% — 95% relative humidity (non -con- densing) Air Duct Velocity: 100 — 4,000 ft/min (0.5 — 20.32 m/s) NOTIFIER by Honeywell Notifier provides system flexibility with a variety of accessories, including two remote test stations and different means of visible and audible system annunciation. As with our duct smoke detectors, all duct smoke detectors accessories are UL listed. DNR(W) housings with a date code of 0013 or higher do not require external 24VDC for remote test applications when used with a remote -test -capable detector, Device Standby Alarm RA10OZ OmA 12mA Max RTS151/RTS1 51 KEY OmA 12mA Max 717,7'�� Consult product manual for lists of compatible UL-Listed devices. In some cases, certain modules may not be listed by certain approval agencies, or listing may be in process. Consult factory for latest list- ing status. UL: S635, S3705 • ULC: S635 CSFM: 3240-1653:0209 FM approved Product Line Information NOTE: "A suffix indicates ULC listed model. DNR(A): Intelligent non -relay photoelectric low flow smoke detector housing. Requires photoelectric smoke detector (sold separately). Watertight intelligent non -relay photoelectric low flow duct smoke detector housing. Requires photoelectric smoke detector (sold separately). NEMA-4 rated, Remote test capable addressable low -profile pho- toelectric smoke detector; ivory; supports CLIP and FlashScan® protocols FSP-95IR(A): Remote test capable addressable low -profile photo- electric smoke detector; white; supports FlashScan protocol only FSP-951(A)-IV: Addressable low -profile photoelectric smoke detec- tor; ivory; supports CLIP and FlashScan protocols FSP-95IR(A): Addressable low -profile photoelectric smoke detec- tor; white; supports FlashScan protocol only DCOIL: Remote test coil. Required for older DNR(W) duct detector housing DUCTCOV: Retrofit DNR cover for manufactured prior to April 2014 DN-60429:C2 - 11/7/2019 — Page 1 of 2 DUCTCOVIN: Retrofit DNRW cover for manufactured prior to April 2014 DST1(A): Metal sampling tube duct width up to 1 ft (0.3m) DST1.5(A): Metal sampling tube duct widths up to 1 ft — 2 ft (0.3 — 0.6 m) DST3(A): Metal sampling tube duct widths up to 2 ft — 4 ft (0.6 — 1.2 m) A): Metal sampling tube duct widths up to 4 ft — 8 ft (1.2 — 2A m) DST10(A): Metal sampling tube duct widths up to 8 ft — 12 ft (2.4 — 3.7 m) DH4000E-1: Weatherproof enclosure ETX: Metal exhaust tube duct, width 1 ft (0.3 m) M02-04-00: Test magnet P48-21-00: End cap for metal sampling tubes RA100Z(A): Remote annunciator alarm LED RTS151(A): Remote test station i iw``(A): Remote test station with key lock Important Notes DNR(W) duct detector housings with a date code of 0013 or higher do not require a DCOIL or auxiliary 24 VDC for remote test applications when used with a remote test capable detector. DNR(W) duct detector housings with a date code of 0012 or ear- lier require a DCOIL and auxiliary 24 VDC power for remote test pp FUllil &INS&MANAFACHRINS QUALITY SYSTEMS This document is not intended to be used for installation purposes. We try to keep our product information up-to-date and accurate. We cannot cover all specific applications or anticipate all requirements. All specifications are subject to change without notice. NOTIFIER 12 Clintonville Road votifier® anc IasrScanO are a registered !raoemarK of honey or nter- 5a Northford, CT 06472 y-,noywei^teratolarc Ai grits es - Jed a _cthorzed 203.484.7161 se rS,".v ,, i'_eu www.notifier.com Country of Origin. Mexico DN-6726:D - H-240 The Notifier NBG-12LX is a state-of-the-art, dual -action (i.e,, requires two motions to activate the station) pull station that includes an addressable interface for any Notifier intelligent control panel except FireWarden series panels, and the NSP- 25 panel. Because the NBG-12LX is addressable, the control panel can display the exact location of the activated manual station. This leads fire personnel quickly to the location of the alarm. TM =- • Maintenance personnel can open station for inspection and address setting without causing an alarm condition. • Built-in bicolor LED, which is visible through the handle of the station, flashes in normal operation and latches steady red when in alarm. • Handle latches in down position and the word "ACTIVATED" appears to clearly indicate the station has been operated. • Captive screw terminals wire -ready for easy connection to SLC loop (accepts up to 12 AWG/3.25 ITIM2 wire). • Can be surface mounted (with SB-10 or SB-1/0) or semi - flush mounted. Semi -flush mount to a standard single - gang, double -gang, or 4" (10.16 cm) square electrical box. • Smooth dual -action design. • Meets ADAAG controls and operating mechanisms guide- lines (Section 4.1.3[13]); meets ADA requirement for 5 lb. maximum activation force. • Highly visible. • Attractive shape and textured finish. • Key reset. • Includes Braille text on station handle, • Optional trim ring (BG12TR). • Meets UL 38, Standard for Manually Actuated Signaling Boxes. • Up to 99 NBG-12LX stations per loop on CLIP protocol loops. • Up to 159 NBG-12LX stations per loop on FlashScanO pro- tocol loops. • Dual -color LED blinks green to indicate normal on FlashScanO systems. Construction Shell, door, and handle are molded of durable polycarbonate material with a textured finish. Specif !cations • Shipping Weight: 9.6 oz. (272.15 g) • Normal operating voltage: 24 VDC. • Maximum SLC loop voltage: 28.0 VDC, • Maximum SLC standby current: 375 pA. • Maximum SLC alarm current: 5 mA. • Temperature Range: 32°F to 120°F (0°C to 49°C) • Relative Humidity: 10% to 93% (noncondensing) • For use indoors in a dry location The NBG-12LX Addressable Manual Pull Statiov TITIT.TrFT"MM The NBG-12LX will mount semi -flush into a single -gang, dou- ble -gang, or standard 4" (10.16 cm) square electrical outlet box, or will surface mount to the model SB-10 or SB-1/0 sur- face backbox. If the NBG-12LX is being semi -flush mounted, then the optional trim ring (BG12TR) may be used. The BG12TR is usually needed for semi -flush mounting with 4" (10.16 cm) or double -gang boxes (not with single -gang boxes). Pushing in, then pulling down on the handle causes it to latch in the down/activated position. Once latched, the word "ACTI- VATED" (in bright yellow) appears at the top of the handle, while a portion of the handle protrudes from the bottom of the station. To reset the station, simply unlock the station with the key and pull the door open. This action resets the handle; clos- ing the door automatically resets the switch. Each manual station, on command from the control panel, sends data to the panel representing the state of the manual switch. Two rotary decimal switches allow address settings It — 159 on FlashScanO systems, 1 — 99 on CLIP systems). 1UAWX47 Specif ications Manual Fire Alarm Stations shall be non -coded, with a key - operated reset lock in order that they may be tested, and so designed that after actual Emergency Operation, they cannot be restored to normal except by use of a key. An operated sta- tion shall automatically condition itself so as to be visually detected as activated. Manual stations shall be constructed of red -colored polycarbonate material with clearly visible operat- ing instructions provided on the cover. The word FIRE shall appear on the front of the stations in white letters, 1,00 inches (2.54 cm) or larger. Stations shall be suitable for surface mounting on matching backbox SB-1 0 or SB-1/0; or semi -flush mounting on a standard single -gang, double -gang, or DN-67260 - 4/13/2012 — Page 1 of 2 4" (10.16 cm) square electrical box, and shall be installed within the limits defined by the Americans with Disabilities Act (ADA) or per national/local requirements. Manual Stations shall be Underwriters Laboratories listed. Manual stations shall connect with two wires to one of the con- trol panel SLC loops, The manual station shall, on command from the control panel, send data to the panel representing the state of the manual switch. Manual stations shall provide address setting by use of rotary decimal switches. The loop poll LED shall be clearly visible through the front of the station. The LED shall flash while in the normal condition, and stay steadily illuminated when in alarm. Product Line Information Dual -action addressable pull station. Includes key locking feature. (Listed for Canadian and non -Canadian appli- cations.) NBG-12LXSP: Spanish/English labelled version. NBG-12LXP: Portuguese labelled version, SB-10: Surface backbox; metal. SB-110: Surface backbox; plastic. BG12TR: Optional trim ring. 17021: Keys, set of two. NY -Plate: New York City trim plate. Agency Listings and Approvals In some cases, certain modules or applications may not be listed by certain approval agencies, or listing may be in pro- cess. Consult factory for latest listing status. • UUULC Listed: S692 (listed for Canadian and non -Cana - than applications). • MEA: 67-02-E. • CSFM: 7150-0028:0199. • FDNY: COA #6085 (NFS2-640), COA #6098 (NFS2-3030). • BSIVII: C1313066760047. • U.S. Coast Guard. • Lloyd's Register. • FM Approved. Patented: U.S. Patent No. D428,351; 6,380,846; 6,314,772; 6,632,108. NOTIFIERO and FlashScan@ are registered trademarks of Honeywell International Inc. 02012 by Honeywell International Inc. All rights reserved. Unauthorized use of this document is strictly prohibited. an U ISO 0901fti This document is not intended to be used for installation purposes. We try to keep our product information up-to-date and accurate. NEE 9:JAiDdlifil We cannot cover all specific applications or anticipate all requirements. All specifications are subject to change without notice. QUALITY SYSTEMS Made in the U.S. A. For more information, contact Notifier. Phone: (203) 484-7161, FAX: (203) 484-7118. www.notifier.com Page 2 of 2 — DN-6726:D - 4/13/2012 Four different monitor modules are available for wobUe/a intelligent control panels for avariety nfapplications. Monitor modules supervise m circuit of dry -contact input devioee, such as conventional heat detectors and pull stoonna, or monitor and power e circuit of mvo+winm amuxo detectors (FzM-1(A)). )iaastanuan|~sizeu module (typically mounts ma 4^ i10.16 cm] square box) that supervises either a Stye D (Class A) or Stye 8 (Class B) circuit of dry -contact input devices. FMM'1V1(\}isaminiature monitor module amere 1.3^ (3.3V2cm) Hx2J5r(0.985cm) VVx0.O5^(1.o51cm) Dthat supervises e Style B (Class B) circuit of dry -contact input devices. Its compact design nxnwo the FMM-101(A) to be mounted inasingle-gang box behind the device nmonitors. FZM-1(A) is a standard -sized module that monitors and supervises compatible mvn+wi,e.24volt, smoke detectors on eStyle D(Class A)orStyle e(Class 8)circuit. FDM-1 (A) is a standard -sized dual monitor module that mon- itors and supervises two independent two-wire8ty|eB(C|mao a)dry-contact initiating device circuits (|DCs)attwo separate, consecutive addresses inintelligent, two -wire systems. p|as»Scmmg (U.S. Patent 5.539.389) is a communication pmmoo| developed byNOT|F|ERthat greatly increases the speed of communication between analog intelligent devices. Intelligent devices communicate inegrouped fashion. |fone of the devices within the group has new in1b,meunn, the panel CPU stops the group poll and concentrates onsingle points. The not effect is response speed greater than five times that of other communication protocols. ` Built-in type identification automatically identifies this device ooamonitor module mthe control panel. ~ Powered directly by m,n+wim SLC loop, No additional power required. ` High noise (EMF/RF|)immunity, ~ SEMSscrews with clamping plates for ease nfwiring, ~ Direct -dial entry ofaddress: O1-159onF|aahScanloops; 01 —99onCLIP loops. ^ LED flashes green during normal operation (pmgramma- b|eoption) and latches unsteady red mindicate alarm. The pMM-1(A) Monitor Module is intended for use in |mem- gont.two-wire systems, where the individual address ufeach module ioselected using the built-in rotary switches. npro- vides edhoramvo+winen,K`unwirehauK+o|*ront|nmatmg Device Circuit (|oC)for normal |y-np*n-contact fire alarm and supervisory devices, The module has epanel-controlled LED indicator. The FMM-1(A) can be used to replace MMX-1(*) mnVu|mu in existing systems. FMM-I(A)APPuCATIONS Use to monitor zone of four -wire smoke detecmm, manual nm alarm pull ata8nns, waoarflmwgev|oeo. prother normally - � ��|���=�~I��I����' by Honeywell WNW open dry -contact alarm activation devices. May also be used to monitor normally -open supervisory devices with special supervisory indication at the oonon| panel. Monitored circuit may uowired msanNppAStyle 8(Class 6)o,Style D(Class A) Initiating Device Circuit. a47KOhm End -of -Line Resistor (pmvideu)terminates the Style Bcircuit. Nnresistor is required for supervision ofthe Style Dcircuit. FMM-Y(A)OPERATION Each FMM-1(A)uses one nfthe available module addresses on ansLCloop. uresponds mregular polls from the o*ntn| panel and reports its type and the status (opon/nonneKohort) ufits Initiating Device Circuit (|DC).Aflashing LED indicates that the module in in communication with the oonun| panel. The LED |ouooas steady on a|enn (subject to current limita- tions FMM-/(A) SPECIFICATIONS Nominal operating voltage: 15m32VOC. Maximum current draw: 5.VmA(LED on). Average operating current: 375 pA(LED Oaohing). 1 com- munication every 5seconds, 47kEOL� Maximum |DCwihmg resistance: 1500Ohma. Maximum |DCWn|tege: 11 Volts. EOLresistance: 47KOhms. Temperature range: 32^F^o120~F(U^Cm4S^C). Humidity range: 10Y6«o93% npncongensing. Dimensions: 4,5^ (1143 cm) high x4^ (1010 cm) wide v 1�35^(3175cm) deep. Mounts tna4^(1U18cm) square x 212r(5.J90cm) deep box. ^ Built-in type identification automatically identifies this device eoamonitor module mthe panel. ^ Powered directly by two -wire GLC loop. No additional power required. ` High noise (EMF/RF|)immunity. ^ Tinned, stripped leads for ease mwiring. ~ Direct -dial entry nfaddress: 01-159onF|mahSuanloops; LOOP TENS ONES Lu The FwM401(A) Mini Monitor Module can be installed in single -gang junction directly behind the mnnunmU unit. Its small size and light weight allow itmUoinstalled without rigid mounting. The FMM-101(A) is intended for use in imeoigeru, two -wire systems where the individual address of each mod- ule is selected using rotary switches. It provides a two -wire initiating device circuit for normally -open -contact Om alarm and security devices. The pMM-101(A) can be used to replace MMX-1O1(A)modules inexisting systems. fMM-101(A)AppLIcAnowa Use mmonitor asingle device mazone ofhmnwre smoke detecmm, manual fire alarm pull stations, watorflwwuevioos. or other normally -open un+nuntuct devices. May also be used tumonitor normally -open supervisory devices with spe- cial nupomienryindino8onmtthoonntm|pane|. Monitored cir- cuit/device is wired as an mrPxSty|e B (Class a) Initiating Device Circuit. A47xOhm Enu-of-LineResistor (pmv|dod) terminates the circuit. FMM-101(A)0PERmmON Each FMM-101VV uses one of the available module addresses onanSLCloop. uresponds Nregular polls from the control panel and reports its type and the status (open/ normal/short) of its Initiating Device Circuit (IDC). FMM101p9SPsrIFIcArnOwa Nominal operating voltage: 15 to 32 VDC. Average operating current: 350 pA. 1 communication every 5seconds, 47kEOL; 000 pAMax, (Communicating, |DC3honed), Maximum U0Cwiring resistance: 150VOhms. Maximum |DcVmltaQ*: M Volts. Maxomwm0C Current: 450pA. EOL resistance: 47K Ohms. Page 2m4—ow-6720:E^07/30/2m Temperature range: 32oFto120oF (OoC to49oC). Humidity range: 10Y6»o93% nunrond*mdnO. Dimensions: 13^(1302cm) high x2J5^(O.9B5cm) wide x O.65"(1.051cm) deep. Wire length: 0^(15.24cm) minimum. FZM~1(A) Interface Module ^ Supports compatible two -wire smoke detectors. ` Supervises |nC wiring and connection of external power source. ~ High noise <EMF/RF0immunity. ~ SEMSscrews with clamping plates for ease ofwiring. - Direct -dial entry entry ofaddress: O1-159unF|eohSoen loops, o1—V9onCLIP loops. ` LED flashes during normal operation; this iue pmgmm- meb|oopuiwn. ` LED latches steady to indicate alarm on command from control panel. The FZM-1(A) Interface Module is intended for use in intelli- gent, addressable systems, where the individual address of each module is oa|octod using built-in rotary switches. This module allows intelligent panels minterface and monitor two - wire conventional smoke d*toomm. It transmits the status (norme|, open, or alarm) of one full zone of conventional detectors back mthe control panel. All mvo+°|m detectors being monitored must he I compatible with the module. The FZM-1(\)can beused toreplace MMX-2(A) modules in existing systems. Use the FZM-1VVto monitor azone of two -wire smoke detectors. The monitored circuit may Unwired amen NFFA Style B (Class B) or Style D (Class A) Initiating Device Cir- cuit. A 3.9 K Ohm End -of -Line Resistor (provided) terminates the end ofthe Style BnrD(class BorA)circuit (maximum |DC|nop moimonoa in25Oxmn), |nma|| ELRacross termi- nals 8and 3for Style Dapplication. FZM-1(A)OpaR:now Each FZM-1VVuses one cfthe available module addresses on an SLC loop. || responds mregular polls from the oonon| panel and reports its type and the status (open/nunne|/oxort) urits Initiating Device Circuit (mc).Aflashing LED indicates that the mvuu|m is in communication with the oonLm| panel. The LED latches steady on u|ann (subject to mvmam limita- tions fZM'I(A)SPECIFICATIONS Nominal operating voltage: 15tu32VDC. Maximum current draw: 5.1mA(LED nn). Maximum |OCwiring resistance: 25Ohms. Average operating current: 270 pA. 1 communication and 1 LED flash every 5seconds, 3.9koo| EOLresistance: 3.9KOhms. E`tornal supply voltage (between Terminals T10 and T}1): ~ DCvoltage: 2^volts power limited. ~ Ripple voltage: 01Vnnomaximum. ~ Current: gOmAper module maximum. Temperature range: 32^Foo120^F(0^Cm48~C). Humidity range: 10% to 93% nonconclensing Dimensions: 4.5" (11.43 cm) high x 4" (10.16 cm) wide x 125" (3,175 cm) deep. Mounts to a 4" (10.16 cm) square x 2.125" (5.398 cm) deep box. The FDM-1 (A) Dual Monitor Module is intended for use in intelli- gent, two -wire systems. It provides two independent two -wire initiating device circuits (IDCs) at two separate, consecutive addresses. It is capable of monitoring normally open contact fire alarm and supervisory devices; or either normally open or nor- mally closed security devices. The module has a single panel - controlled LED. NOTE. The FDM-I(A) provides two Style B (Class B) 1DC circuits ONLY Style D (Class A) 1DC circuits are NOT supported in any application. FDM-I(A) SPECIFICATIONS Normal operating voltage range: 15 to 32 VDC. Maximum current draw: 6.4 mA (LED on). Average operating current: 750 pA (LED flashing). Maximum IDC wiring resistance: 1,500 Ohms. Maximum IDC Voltage: 11 Volts. Maximum IDC Current: 240 pA EOL resistance: 47K Ohms. Temperature range: 32' to 120'F (0' to 49'C). Humidity range: 10% to 93% (non -condensing). Dimensions: 4,5" (11.43 cm) high x 4" (10.16 cm) wide x 1.25" (3.175 cm) deep. Mounts to a 4" (10.16 cm) square x 2.125" (5.398 cm) deep box. FDM-I(A) AuTowm ADDRESSING The FDM-1 (A) automatically assigns itself to two address- able points, starting with the original address. For example, if the FDM-1 (A) is set to address "26", then it will automatically assign itself to addresses "26" and "27". NOTE: "Ones" addresses on the FDM-I(A) are 0, 2, 4, 6, or 8 only, Terminals 6 and 7 use the first address, and terminals 8 and 9 use the second address. CAUTION: Avoid duplicating addresses on the system. FMM-1 (A), FZM-1 (A), and FDM-1 (A) modules mount directly to a standard 4" (10.16 cm) square, 2.125" (5.398 cm) deep, electrical box. They may also be mounted to the SMB500 surface -mount box. Mounting hardware and installation instructions are provided with each module. All wiring must conform to applicable local codes, ordinances, and regula- tions. These modules are intended for power -limited wiring only. The FMM-101(A) module is intended to be wired and mounted without rigid connections inside a standard electri- cal box. All wiring must conform to applicable local codes, ordinances, and regulations. In some cases, certain modules may not be listed by certain approval agencies, or listing may be in process. Consult fac- tory for latest listing status. • UL: S635, • ULC: S635. FM Approved. • CSFM: 7300-0028:0219, 7165-0028:0224, 7165-0028:0243. • MEA: 457-99-E. • U.S. Coast Guard: 161.002/50/0 (NFS2-640, NFS2-320, NFS2-3030). • Lloyd's Register: 11/600013 (NFS2-640, NFS2-320, NFS2-3030). • Fire Dept. of New York: COA #6121 (NFS2-640, NFS- 320), COA# 6114 (NFS2-3030). Product Line Information NOTE: "A" suffix indicates ULC-listedmadeL 4 ,(A): Monitor module, FMM-101(A): Monitor module, miniature. FZM-1(A): Monitor module, two -wire detectors. FDM-I(A): Monitor module, dual, two independent Class B circuits. SMB500: Optional surface -mount backbox. NOTE: See installation instructions and refer to the SLC Wiring Manual, PN 51253. DN-6720:E • 07/30/2015 — Page 3 of 4 FlashScan(D and NOTIFIER@) are registered trademarks and FireWatchT" is a trademark of Honeywell International Inc. @2015 by Honeywell International Inc. All rights reserved. Unauthorized use of this document is strictly prohibited. ISO109001 This document is not intended to be used for installation purposes. We try to keep our product information up-to-date and accurate. 9_5_ULaLdJJ-tJ_=L'J we cannot cover all specific applications or anticipate all requirements. ENSIMERING & MANURTINNG All specifications are subject to change without notice. QUALITY SYSTEMS For more information, contact Notifier. Phone: (203) 484-7161, FAX: (203) 484-7118. www.notifier.com Page 4 of 4 — DN-6720:E - 07/30/2015 DN-6724:133 ECM-1(A) Control Module: The FCM-1 (A) Addressable Con- trol Module provides Notifier intelligent fire alarm control pan- els a circuit for Notification Appliances (horns, strobes, speakers, etc.). Addressability allows the FCM- 1 (A) to be acti- vated, either manually or through panel programming, on a select (zone or area of coverage) basis. A) Relay Module: The FRM-1 (A) Addressable Relay Module provides the system with a dry -contact output for acti- vating a variety of auxiliary devices, such as fans, dampers, control equipment, etc. Addressability allows the dry contact to be activated, either manually or through panel programming, on a select basis. FlashScan@ (U.S. Patent 5,539,389) is a communication pro- tocol developed by NOTIFIER Engineering that greatly enhances the speed of communication between analog intelli- gent devices. Intelligent devices communicate in a grouped fashion. If one of the devices within the group has new infor- mation, the panel CPU stops the group poll and concentrates on single points. The net effect is response speed greater than five times that of other designs. I • Built-in type identification automatically identifies these devices to the control panel. • Internal circuitry and relay powered directly by two -wire SLC loop. The FCM-1 (A) module requires power (for horns, strobes, etc.), or audio (for speakers). • Integral LED "blinks" green each time a communication is received from the control panel and turns on in steady red when activated. • LED blink may be deselected globally (affects all devices). • High noise immunity (EMF/RFI). • The FCM-1 (A) may be used to switch 24-volt NAC power, audio (up to 70.7 Vrms). • Wide viewing angle of LED. • SEMS screws with clamping plates for wiring ease. • Direct -dial entry of address 01— 159 for FlashScan loops, 01 — 99 for CLIP mode loops. • Speaker, and audible/visual applications may be wired for Class B or A (Style Y or Z). The FCM-1 (A) is used to switch 24 VDC audible/visual power, high-level audio (speakers). The FRM-1(A) may be pro- grammed to operate dry contacts for applications such as door holders or Air Handling Unit shutdown, and to reset four -wire smoke detector power. NOTE. Refer to the SLC Manual (PN 51253) for details regarding releasing applications with the FCM- 1 (A). Refer to the FCM- 1 -REL datasheet (DN-60390) for new FlashScanO releasing applications. • The face plate is made of off-white heat -resistant plastic. • Controls include two rotary switches for direct -dial entry of address (01-159). NOTIFIER ®R by Honeywell waam • The FCM-1(A) is configured for a single Class B (Style Y) or Class A (Style Z) Notification Appliance Circuit, • The FRM-1(A) provides two Form-C dry contacts that switch together. Each FCM-1 (A) or FRM-1 (A) uses one of 159 possible module addresses on a SLC loop (99 on CLIP loops). It responds to regular polls from the control panel and reports its type and status, including the open/normal/short status of its Notifica- tion Appliance Circuit (NAC). The LED blinks with each poll received. On command, it activates its internal relay. The FCM-1(A) supervises Class B (Style Y) or Class A (Style Z) notification or control circuits. Upon code command from the panel, the FCM-1(A) will dis- connect the supervision and connect the external power sup- ply in the proper polarity across the load device. The disconnection of the supervision provides a positive indication to the panel that the control relay actually turned ON. The external power supply is always relay isolated from the com- munication loop so that a trouble condition on the external power supply will never interfere with the rest of the system. Rotary switches set a unique address for each module. The address may be set before or after mounting. The built-in TYPE CODE (not settable) will identify the module to the con- trol panel, so as to differentiate between a module and a sen- sor address. Specifications for FCM-1 (A) Normal operating voltage: 15 to 32 VDC. Maximum current draw: 6.5 mA (LED on). Average operating current: 350 pA direct poll, 375 pA group poll with LED flashing, 485 pA Max. (LED flashing, NAC shorted.) DN-6724:B3 - 2/17/2011 — Page 1 of 2 Maximum NAC Line Loss: 4 VDC. External supply voltage (between Terminals T10 and T11): Maximum (NAC): Regulated 24 VDC; Maximum (Speakers): 70.7 V RMS, 50W. Drain on external supply: 1.7 mA maximum using 24 VDC supply; 2.2 mA Maximum using 80 VRMS supply. Max NAC Current Ratings: For class B wiring system, the current rating is 3A; For class A wiring system, the current rat- ing is 2A. Temperature range: 32°F to 120°F (0°C to 49'C). Humidity range: 10% to 93% non -condensing. Dimensions: 4.5" (114.3 mm) high x 4" (101,6 mm) wide x 1.25" (31.75 mm) deep. Mounts to a 4" (101.6 mm) square x 2.125" (53.975 mm) deep box. Accessories: SMB500 Electrical Box; CB500 Barrier Normal operating voltage: 15 to 32 VDC. Maximum current draw: 6.5 mA (LED on). Average operating current: 230 pA direct poll; 255 pA group poll. EOL resistance: not used. Temperature range: 32°F to 120°F (0°C to 49'C). Humidity range: 10% to 93% non -condensing. Dimensions: 4.5" (114.3 mm) high x 4" (101.6 mm) wide x 1.25" (31.75 mm) deep. Mounts to a 4" (101.6 mm) square x 2.125" (53.975 mm) deep box. Accessories: SMB500 Electrical Box; CB500 Barrier Agency Listings and Approvals In some cases, certain modules may not be listed by certain approval agencies, or listing may be in process. Consult fac- tory for latest listing status. • LIL: S635 • ULC: S3705 (A version only) • FM Approved • CSFM: 7300-0028:0219 • MEA: 14-00-E • FDNY: COA #6067, #6065 Current Maximum Load Application Rating Voltage Description 3 A 30 VDC Resistive Non -Coded 2 A 30 VDC Resistive Coded .9 A 110VDC Resistive Non -Coded .9 A 125 VDC Resistive Non -Coded A 30 VDC Inductive Coded .5 (L/R=5ms) 1 A 30 VDC Inductive Coded (L/R=2ms) A 125 VAC Inductive Non -Coded .3 (PF=035) Inductive 1,5 A 25 VAC (PF=0.35) Non -Coded Inductive .7 A 70.7 VAC (PF=0.35) Non -Coded Inductive 2 A 25 VAC (PF=035) Non -Coded NOTE: Maximum (Speakers): 70.7 V RMS, 50 IN Product Line Information NOTE: "A" suffix indicates ULC Listed model. FCM-1(A): Intelligent Addressable Control Module. f A): Intelligent Addressable Relay Module, A2143-20: Capacitor, required for Class A (Style Z) operation of speakers. SMB500: Optional Surface -Mount Backbox. CB500: Control Module Barrier — required by LL for separat- ing power -limited and non -power limited wiring in the same junction box as FCM- 1 (A). NOTE: For installation instructions, see the following documents: • FCM- I (A) Installation document 156-1169. • FRM- I(A) Installation document 156-3502. • Notifier SLC Wiring Manual, document 51253. Notifler@ and FlashScan@ are registered trademarks of Honeywell International Inc. (92011 by Honeywell International Inc. All rights reserved. Unauthorized use of this document is strictly prohibited. IS09001We This document is not intended to be used for installation purposes. try to keep our product information up-to-date and accurate. We cannot cover all specific applications or anticipate all requirements. ENSINEERINC a MAMNUMUCT IIING All specifications are subject to change without notice. QUALITY SYSTEMS For more information, contact Notifier. Phone: (203) 484-7161, FAX: (203) 484-7118. www.notifier.com Page 2 of 2 — DN-6724:63 - 2/17/2011 DN-60918:13 LW mom 77, NOTIFIER by Honeywell The L-Series offers the most versatile and easy -to -use line of horns, strobes, and horn strobes in the industry with lower cur- rent draws and modern aesthetics. With white and red plastic housings, standard and small footprint devices, and plain, FIRE -printed devices, L-Series can meet virtually any applica- tion requirement. The L-Series product line of wall -mount horns, strobes, and horn strobes include a variety of features that increase their application versatility while simplifying installation. All devices feature plug-in designs with minimal intrusion into the back box, making installations fast and foolproof while virtually elim- inating costly and time-consuming ground faults. To further simplify installation and protect devices from con- struction damage, L-Series utilizes a universal mounting plate for all standard and compact models with an onboard shorting spring, so installers can test wiring continuity before the device is installed. Installers can also easily adapt devices to a suit a wide range of application requirements using field -selectable candela set- tings, automatic selection of 12- or 24-volt operation, and a rotary switch for horn tones with two volume selections. 477i=_ I • Updated modern aesthetics. • Small profile devices for Horns and Horn Strobes. • Plug-in design with minimal intrusion into the back box, • Tamper -resistant construction. • Automatic selection of 12- or 24-volt operation at 15 and 30 candela. • Field -selectable candela settings on wall units: 15, 30, 75, 95, 110, 135, and 185. • Horn rated at 88+ dBA at 16 volts. • Rotary switch for horn tone and two volume selections. • Universal mounting plate for all standard and all compact wall units. • Mounting plate shorting spring checks wiring continuity. before device installation. • Electrically Compatible with legacy SpectrAlerto and SpectrAlert Advance devices. • Compatible with MDO sync module. • Listed for wall mounting only. General: L-Series standard horns, strobes, and horn strobes shall mount to a standard 2" x 4" x 17/8 " back box, 4" x 4" x 11/2" back box, 4" octagon back box, or double -gang back box. L-Series compact products shall mount to a single -gang 2" x 4" x 17/8 " back box. A universal mounting plate shall be used for mounting ceiling and wall products for all standard -size models and a separate universal mounting plate shall be used for mounting compact wall models. The notification appliance circuit wiring shall terminate at the universal mounting plate. Also, L-Series products, when used with the Sync-CircUitTM Module accessory, shall be powered from a non -coded notifi- cation appliance circuit output and shall operate on a nominal 15M M, R� 0", . .. . ...... P2GWL SGWL mm 12 or 24 volts. When used with the Sync -Circuit Module, 12- volt-rated notification appliance circuit outputs shall operate between 8.5 and 17.5 volts; 24-volt-rated c appliance circuit outputs shall operate between 16.5 and 33 volts. Indoor L-Series products shall operate between 32 and 120 degrees Fahrenheit from a regulated DC or full -wave rectified unaltered power supply. Strobes and horn strobes shall have field -select- able candela settings including 15, 30, 75, 95, 110, 135, and 185. Strobe, The strobe shall be a L-Series Model listed to UL 1971 and shall be approved for fire protective service. The strobe shall be wired as a primary -signaling notification appli- ance and comply with the Americans with Disabilities Act requirements for visible signaling appliances, flashing at 1 Hz over the strobe's entire operating voltage range. The strobe light shall consist of a xenon flash tube and associated lens/ reflector system. DN-60918:B - 5/19/17 — Page 1 of 4 Horn Strobe Combination. The horn strobe shall be a L-Series Model listed to UL 1971 and UL 464 and shall be approved for fire protective service. The horn strobe shall be wired as a primary -signaling notification appliance and comply with the Americans with Disabilities Act requirements for visi- ble signaling appliances, flashing at 1 Hz over the strobe's entire operating voltage range. The strobe light shall consist of a xenon flash tube and associated lens/reflector system. The horn shall have two audibility options and an option to switch between a temporal three pattern and a non -temporal (contin- uous) pattern. These options are set by a multiple position switch. The horn on horn strobe models shall operate on a coded or non -coded power supply. Synchronization Module. The module shall be a Sync•Circuit model MDL3 listed to UL 464 and shall be approved for fire protective service. The module shall synchronize SpectrAlert strobes at 1 Hz and horns at temporal three. Also, while oper- ating the strobes, the module shall silence the horns on horn strobe models over a single pair of wires. The module shall mount to a 411/," x 411/16" x 21/," back box. The module shall also control two Style Y (class B) circuits or one Style Z (class A) circuit. The module shall synchronize multiple zones. Daisy chaining two or more synchronization modules together will synchronize all the zones they control. The module shall not operate on a coded power supply. PHYSICAUELECTRICAL SPECIFICATIONS • Standard Operating Temperature: 32°F to 120°F (0°C to 49-C). • Humidity Range. 10 to 93% non -condensing. • Strobe Flash Rate: 1 flash per second. • Nominal Voltage: Regulated 12 DC or regulated 24 DC/ FWR1 (full wave rectified). • Operating Voltage Range2: 8 to 17.5 V (12 V nominal) or 16 to 33 V (24 V nominal). • Operating Voltage Range: MDL3 Sync Module 8.5 to 17.5 V (12 V nominal) or 16.5 to 33 V (24 V nominal). • Input Terminal Wire Gauge: 12 to 18 AWG. • Wall -Mount Dimensions (including lens): 5.6" L x 4.7" IN x 1.25" D (143 mm L x 119 mm W x 32 mm D). • Compact Wall -Mount Dimensions (including lens): 5.26" L x 3.46" W x 1 .93" D (133 mm L x 88 mm W x 49 mm D). • Horn Dimensions: 5.6" L x 4.7" W x 1.25" D (143 mm L x 119 mm W x 32 mm D). • Compact Horn Dimensions: 5.25" L x 3.45" W x 1.25" D (1 33mm L x 88mm W x 32mm D). NOTE: 1. Full Wave Rectified (FWR) voltage is a non -regulated, time - varying power source that is used on some power supply and panel outputs. 2. P, S, PC, and SC products will operate at 12 V nominal only for 15 cd and 30 cd. Page 2 of 4 — DN-60918:B • 5/19/17 I 15--f-Tif _TT •• '• mmmr,�•• Combo 4.70 J 5.67 1.91 1,2E 1.25 Eli Mqu= a U771MOTM ! 91AM &Lg The 3.1k is the sound of the mini -horns. The EM (which stands for Electro-mechanical) is the sound of the SpectrAlert Advance line which uses an algorithm that hops frequencies between 2Hz and 4Hz. Sound Pattern Temporal dB High 8-17.5 volts 16-33 Voft DC 39 DC 44 FWR 54 Temporal Low 28 32 54 Non -Temporal High 43 47 54 Non -Temporal Low 29 32 54 3.1 KHz Temporal High 39 41 54 1 3.1 KHz Temporal Low 29 32 54 3.1 KHz Non -Temporal High 42 43 54 3.1 KHz Non -Temporal Low 28 29 54 Coded High 43 47 54 3.1 KHz Coded High 42 43 54 The 3.1 k is the sound of the mini -horns. The EM (which stands for Elect ro- mechanical) is the sound of the SpectrAlert Advance line which uses an algorithm that hops frequencies between 2Hz and 4Hz. DC Input: 8-17.5 FWR Input: volts 16 FWR 157 3-0 95 1110 135 185 15 30 75 95 110 55 185 cd cd v cd cd cd cd cd cd cd cd cd cd cd Temporal High 98 158 1t 142 162 196 245 83 107 156 177 198 234 287 Temporal Low 93 154 44 65 111 133 157 184 235 68 91 145 165 185 223 271 Non -Temporal High 106 166 73 94 139 160 182 211 262 111 135 185 207 230 264 316 Non-TemporalLow 93 156 51 71 119 139 162 1901 239 79 104 157 175 197 235 283 11 K Temporal High 93 156 53 73 119 140 164 190 242 81 105 155 177 196 234 284 3.1 K Temporal Low 91 154 45 66 112 133 160 185 235 68 90 145 166 186 222 276 3.1 K Non -Temporal High 99 162 69 90 135 157 175 208 261 104 131 177 204 230 264 32 3.1 K Non -Temporal Low 72 119 138 162 192 242 77 102 156 177 199 1 234 291 DN-60918:B - 5/19/17 — Page 3 of 4 HORN TONES AND SOUND OUTPUT DATA: HORN Product Line Information A The 3.1 k is the sound of the mini -horns. The EM (which stands for Electro-mechanical) is the sound of the SpectrAlert Advance line which uses an algorithm that hops frequencies between 2Hz and 4Hz. In the coded positions, temporal coding must be provided by the NAC. If the NAC voltage is held constant, the horn output will remain constantly on. Pos. 1 Sound Pattern Temporal dB High 8-17.5 volts 16-33 Volts DC 84 DC 89 FWR 89 2 1 Temporal Low 75 83 83 3 Non -Temporal High 85 90 90 4 Non -Temporal Low 76 84 84 5 3.1 KHz Temporal High 83 88 88 6 3.1 KHz Temporal Low 76 82 82 7 3.1 KHz Non -Temporal High 84 89 89 3.1 KHz Non -Temporal Low 77 83 83 9t Coded High 85 90 90 10t 3.1 KHz Coded High 84 89 89 tSettings 9 and 10 are not available on the 2-wire horn strobes. The listings and approvals below apply to L-series devices. In some cases, certain modules or applications may not be listed by certain approval agencies, or listing may be in process. Consult factory for latest listing status. • UL/ULC-Listed — S4011 Wall Horn Strobes — S5512 Wall Strobes — S5512 Wall Horns — S5512 Strobe -only ALERT devices • FM Approved (All except ALERT models) • CSFM Listed: 7135-1653:0503 (Wall Horns and Wall Horn Strobes), 7125-1653:0504 (Wall Strobes) WALL H N 61ROBEN P2WL(A)(-E)(+), '�"1QA)(-E)(+). 2-Wire, Horn Strobe (White, Red). P2GWL(A)(-E)(+), P2GRL(A)(-E)(+). 2-Wire, Compact Horn Strobe (White, Red). P2WL(A)-P, P2RL(A)-P. 2-Wire, Horn Strobe, Plain (White, Red). P2WL-SP, P2RL-SR 2-Wire, Horn Strobe, FUEGO (White, Red), WALL STROBES SWL(A)(-E)(-F),,$f'f A)(-E)(-F). Strobe, Red (White, Red). SGWL(A)(-E)(+), SGRL(A)(-E)(-F). Compact Strobe (White, Red). SWL(A)-P, SRL(A)-P. Strobe, Plain (White, Red). SRL-SP. Strobe, FUEGO (Red). SWL-CLR-ALERT. Strobe, ALERT (White). SWL-ALERT. Strobe, Wall, Amber Lens, ALERT (White). HORNS HVIL(A), HRL(A). Horn (White, Red). HGWL(A), HGRL(A). Compact Horn (White, Red). ACCESSORIES TR-21N, TR-2. Universal Wall Trim Ring (White, Red). SBBWL, SBBRL. Wall Surface Mount Back Box (White, Red). SBBGWL, SBBGRL. Compact Wall Surface Mount Back Box (White, Red). NOTE: 'A" suffix indicates ULC-Listed model. ULC-listed devices include required French labeling. See Agency Listings for listing details. NOTE: "A" suffix indicates ULC-listed models, ULC models have FIRE/FEU marking on cover. NOTE: ULC-listed models add `-E" suffix for English only "FIRE" marking on cover. NOTE. ULC-listed models add "-F" suffix for French only "FEU" marking on cover. NOTIFIERO and SpectrAlert@ are registered trademarks and Sync -Circuits"" is a trademark of Honeywell International Inc, 02017 by Honeywell International Inc. All rights reserved. Unauthorized use of this document is strictly prohibited. This document is not intended to be used for installation purposes, ISOan We try to keep our product information up-to-date and accurate. 191001 We cannot cover all specific applications or anticipate all requirements. IL:A A iibAJAJ_AJ, ENGINEERING & MANUFACTURING All specifications are subject to change without notice. QUALITY SYSTEMS For more information, contact Notifier. Phone: (203) 484-7161, FAX: (203) 484-7118. www.notifier.com Page 4 of 4 — IDN-60918:13 - 5/19/17