Loading...
HomeMy WebLinkAbout23-7083City of Zephyrhills 5335 Eighth Street Zephyrhills, FIL 33542 Phone: (813) 780-0020 Fax: (813) 780-0021 ELCMISC-007083-2023 Issue Date: 10/20/2023 REINSPECTION FEES: (c) With respect to Reinspection fees will comply with Florida Statute 553.80(2)(c) the local government shall impose a fee of four times the amount of the fee imposed for the initial inspection or first reinspection, whichever is greater, for each subsequent reinspection. Notice: In addition to the requirements of this permit, there may be additional restrictions applicable to this property that may be found in the public records of this county, and there may be additional permit required from other governmental entities such as water management, state agencies or federal agencies. !!�111 '11!j !!!!!I 11111111ppil �1111!1 1�1111 Uomplete Plans, Specifications add fee Must Accompany Application. All work shall be performed in accordance with City Codes and Ordinances. NO OCCUPANCY BEFORE C.O. NO OCCUPANCY BEFORE C.O. CONTRACTOR SIGNATURE PE IT OFFICEt) PERMIT EXPIRES IN 6 MONTHS WITHOUT APPROVED INSPECTIO CALL FOR INSPECTION - 8 HOUR NOTICE REQUIRD E PROTECT CARD FROM WEATHER i 813-780-DO20 City of Zephyrhills Permit Application Fa$-813-780-0021 Building Department (813 x.. }Ii,....: Ownet's Address No LOM I Wd Owner Phone Number Fee Simple Titleholder Name Owner Fee Simple Titleholder Address JOB ADDRESS :31oq(9q ti ,. SUBDMSION PARCELID# .. (OBTAINED FROM PROPERTY TAX NOTICE) WORK PROPOSED NEWCONSTRF-1 ADDIALT SIGN DEMOLISH INSTALL REPAIR PROPOSED USE SFR COMM OTHER TYPE OF CONSTRUCTION BLOCK E] FRAME STEEL DESCTIPTION OF WORK [installation of a roof -mounted photovoltaic solar panel system. BUILDING SIZE SQ FOOTAGE HEIGHT aaaassae.eacaaaae_+ec�ee.�ececeeaexs�cee.a.a.cce.ce,�e�+c�[e�exe�em.e.ae.e,��e�s�saeec� [_BUILDING VALUATION OF TOTAL CONSTRUCTION ELECTRICAL $ ®� AMP SERVICE PROGRESS ENERGY = W.RE.C. PLUMBING $ MECHANICAL $ VALUATION OF MECHANICAL INSTALLATION GAS ROOFING SPECIALTY = OTHER FINISHED FLOOR ELEVATIONS FLOOD ZONE AREA =YES NO x +'Sunrun Installation �52s! TampaBlvd, Tampa FL 336341 . •• RESIDENTIALBuildingPlans; Energy R-O-W Permit for new construction, Minimum ten (10) working days after submittal date, Required onsite, Construction Plans, Stormwater Plans w/ Sift Fence installed, Sanitary Facilities & I dumpster; Site Work Permit for subdivisionsAarge projects COMMERCIAL Attach (2) complete sets of Building Plans plus a Life Safety Page; (1) set of Energy Forms, R-O-W Perrnit for new comstmotion, Minimum ten r days after submittal date. Required Sanitary Facilities & I dumpster. Site Work Permit for all new projects. At[ commercial requirements must meet compliance SIGN PERMIT Attach (2) sets of Engineered Plans. *'—PROPERTY SURVEY required for all NEW construction. completely - Owner If over $2500, a Notice of Commencement Is required. (A/C upgrades over 00 `. Agent (for the contractor) or Power of Attorney (for the owner) would be someone with notarized letter from owner authorizing same OVER THE COUNTER PERMITTING (copy of contract required) Rerools if shingles sewers Service Upgrades A/C Fences (Plot/Surreffootage) Driveways -Not over Counter if on public roadways —needs ROW 813-780-0020 City of Zephyrhills Permit Application Fax-813-780-0021 Sul ding Department NOTICE OF DEED RESTRICTIONS: The undersigned understands that this permit may be subject to "deed" restrictions' which may be more restrictive than County regulations. The undersigned assumes responsibility for compliance with any applicable deed restrictions. UNLICENSED CONTRACTORS AND CONTRACTOR RESPONSIBILITIES: If the owner has hired a contractor or contractors to undertake work, they may be required to be licensed in accordance with state and local regulations. If the contractor is not licensed as required by law, both the owner and contractor may be cited for a misdemeanor violation under state law. if the owner or Intended contractor are uncertain as to what licensing requirements may apply for the intended work, they are advised to contact the Pasco County Building Inspection Division --Licensing Section at 727-847- 8DO9. Furthermore, if the owner has hired a contractor or contractors, he is advised to have the oontractor(s) sign portions of the "contractor Block" of this application for which they will be responsible. If you, as the owner sign as the contractor, that may be an indication that he is not properly licensed and is not entitled to permitting privileges In Pasco county. TRANSPORTATION IMPACT/UTILITIES IMPACT AND RESOURCE RECOVERY FEES: The undersigned understands that Transportation Impact Fees and Recourse Recovery Fees may apply to the construction of new buildings, change of use In existing buildings, or expansion of existing buildings, as specified In Pasco County ordinance number 89-07 and 90-07, as amended. The undersigned also understands, that such fees, as may be due, will be identified at the time of permitting. It is further understood that Transportation Impact Fees and Resource Recovery Fees must be paid prior to receiving a 'certificate of occupancy" or final power release, If the project does not involve a certificate of occupancy or final power release, the fees must be paid prior to permit issuance. Furthermore, if Pasco County Water/Sewer Impact fees are due, they must be paid prior to permit issuance in accordance with applicable Pasco County ordinances. CONSTRUCTION LIEN LAW (Chapter 713, Florida Statutes, as amended): It valuation of work Is $2,500. DO or more, I certify that 1, the applicant, have been provided with a copy of the 'Florida Construction Lion Law —Homeowner's Protection Guide' prepared by the Florida Department of Agriculture and Consumer Affairs. If the applicant is someone other than the 'owner, I certify that I have obtained a copy of the above described document and promise in good faith to deliver it to the 'owner prior to commencement. CONTRACTOWSIOWNER'S AFFIDAVIT: I certify that all the information in this application is accurate and that all work will be done in compliance with all applicable laws regulating construction, zoning and land development. Application is hereby made to obtain a permit to do work and installation as indicated, I certify that no work or installation has commenced prior to issuance of a permit and that all work will be performed to meet standards of all laws regulating construction, County and City codes, zoning regulations, and land development regulations in the jurisdiction. I also certify that I understand that the regulations of other government agencies may apply to the intended work, and that it is my responsibility to identify what actions I must take to be in compliance. Such agencies include but are not limited to: - Department of Environmental Protection -Cypress Bayheards, Welland Areas and Environmentally Sensitive Lands, Water/Wastewater Treatment. - Southwest Florida Water Management District -Wells, Cypress Bayheads, Wetland Areas, Altering Watercourses. - Army Corps of Engineers -Seawalls, Docks, Navigable Waterways. - Department of Health & Rehabilitative Services/Environmental Health Unit -Wells, Wastewater Treatment, Septic Tanks, - US Environmental Protection Agency -Asbestos abatement. - Federal Aviation Authority -Runways. I understand that the following restrictions apply to the use of fill: Use of fill is not allowed in Flood Zone 'V° unless expressly permitted. If the fill material is to be used in Flood Zone "A", it is understood that a drainage plan addressing a "compensating volume" Will be submitted at time of permitting which is prepared by a professional engineer licensed by the State of Florida. If the fill material is to be used in Flood Zone "A" in connection with a permitted building using stem wall construction, I certify that fill Will be used only to fill the area within the stem wall. If fill material is to be used in any area, I certify that use of such fill will not adversely affect adjacent properties, If use of fill is found to adversely affect adjacent properties, the owner may be cited for violating the conditions of the building permit issued under the attached permit application, for lots less than one (1) acre which are elevated by fill, an engineered drainage plan is required. If t am the AGENT FOR THE OWNER, I promise in good faith to inform the owner of the permitting conditions set forth in this affidavit prior to commencing construction. I understand that a separate permit may be required for electrical work, plumbing, signs, wells, pools, air conditioning, gas, or other installations not specifically included in the application. A permit issued shall be construed to be a license to proceed with the work and not as authority to violate, cancel, alter, or set aside any provisions of fthe technical codes, nor shall issuance of a permit prevent the Building Official from thereafter requiring a correction of errors in plans, construction or violations of any codes. Every permit Issued shall become invalid unless the work authorized by such permit Is commenced within six months of permit issuance, or if work authorized by the permit is suspended or abandoned for a period of six (6) months after the time the work is commenced. An extension may be requested, in writing, from the Building Official for a period not to exceed ninety (90) days and will demonstrate justifiable cause for the extension. If work ceases for ninety (90) consecutive days, the job is considered abandoned. 111ML101 I I I a U 1.1 U:J A Z4 W1111111111 g"41 I R I Z 11[4 Z4 I A LAMN 01,1 CONTRACTOR;;,��!` this Subscribed z �r has/have produced )Xho i!fare personally known to me or hasMave produced identification. as dentification. � Public Notary Public �Notary rd Commission No, F? ir i 4+n L, LA 1f1t*/ Name of Notary typed, on d or stamped Name of otary d printed o stem October 2, 2023 Subject : Structural Certification for Proposed Residential Solar Installation. Job Number: 802R-464ONEI; Rev A Client: Brian Oneil Address: 36464 Garden Wall Wy, Zephyrhills, FL 33541 Attn: To Whom It May Concern Astral V. 1. 810 p ru n WS ,,w CAT 1 EN James Matthew Walsh, State of Florida. 7 Professional Engineer, License No. 84923 92 "A" f item has been digitally signed and sealed el Z by James Matthew Walsh, PE on 10/2/2023 STATE OF Z- 0 using a Digital Signature. Printed copies of this tORM document are not considered signed and sealer /ONAV, and the SHA authentication code must be verified on electronic copies, ///// I 1111 kt\\\\ Exp. 2f28/2025 10/212023 A field observation of the existing structure at the address indicated above was performed by a site survey team from Sunrun. Structural evaluation of the loading was based on the site observations and the design criteria listed below. Design Criteria: 2020 FBC (7th Ed.) AMENDMENTS TO 2018 IRC/IBC/IEBC, 7-16 ASCE & 2018 NDS • Basic (Category 11) Wind Speed V = 138 mph, Exposure B • Ground Snow Load = 0 psf Based on this evaluation, I certify that the alteration to the existing structure by the installation of the PV system meets the requirements of the applicable existing and/or new building code provisions referenced above. Additionally, I certify that the PV module assembly including all attachments supporting it have been reviewed to be in accordance with the manufacturer's specifications. Results Summary (Hardware Check Includes Uplift Check on Attachments/Fastener, Structure Check Considers Main Structure) Orientation Min. # Mounts per up -slope edge Configuration Max OCR Result AR-01 Landscape Portrait 2 2 NA NA 67% 67% Pass Pass Roofing Material Pitch Structure Check Comp Shingle 22' Pass Orientation Min. # Mounts per up -slope edge Configuration Max OCR Result AR-02 Landscape Portrait 2 2 NA NA 67% 67% Pass Pass Roofing Material Pitch Structure Check Comp Shingle- 23' Pass 225 Bush St. Suite 1400 San Francisco, CA 94104 SHEETINDEX LEGEND SCOPE OF WORK GENERAL NOTES PAGE # DESCRIPTION - SYSTEM SIZE: 9720W DC, 960OW AC ® ALL WORK SHALL COMPLY WITH 2O20 FBC (7TH ED.) AMENDMENTS TO 2018 PV-1.0 COVER SHEET SE SERVICE ENTRANCE ® MODULES: (24) HANVd HA Q-CELLS: Q.PEAK DUO BLK IRC/IBC/IESC, MUNICIPAL CODE, AND ALL MANUFACTU ERS" LISTINGS AND ML-G10+ 405 INSTALLATION INSTRUCTIONS, PV-2,0 SITE PLAN - INVERTERS: (1) DELTA ELECTRONICS: E10-TL-US e PHOTOVOLTAIC SYSTEM WILL COMPLY WITH NEC 2017. MP MAIM PANEL - RACKING: TOPSPEED, SEE DETAIL SNR-DC-30004 ® ELECTRICAL SYSTEM GROUNDING WILL COMPLY WITH NEC 2017. PV-3.0 LAYOUT - MAIN BREAKER DERATE: REPLACE EXISTING 200 AMP MAIN - PHOTOVOLTAIC SYSTEM IS UNGROUNDED, NO CONDUCTORS ARE SOLIDLY PV-4.0 ELECTRICAL BREAKER WITH NEW 175 AMP MAIN BREAKER. GROUNDED IN THE INVERTER. SYSTEM COMPLIES WITH 690.35. SP SUB -PANEL - RAPID SHUTDOWN: (24) APSMART RSD-S-PLC ROOFTOP ® MODULES CONFORM TO AND ARE LISTED UNDER UL 61730. PV-5.0 SIGNAGE MODULE LEVEL RAPID SHUTDOWN DEVICE m INVERTER CONFORMS TO AND IS LISTED UNDER UL 1741. ® RACKING CONFORMS TO AND IS LISTED UNDER UL 2703. LC PV LOAD CENTER SNAPNRACK RACKING SYSTEMS, IN COMBINATION WITH TYPE 1, OR TYPE 11 MODULES, ARE CLASS A FIRE RATED, RAPID SHUTDOWN REQUIREMENTS MET WHEN INVERTERS AND ALL SM SUNRUN METER CONDUCTORS ARE WITHIN ARRAY BOUNDARIES PER NEC 690.12(1). ® CONSTRUCTION FOREMAN TO PLACE CONDUIT RUN PER 690,31(G). ARRAY DC CONDUCTORS ARE SIZED FOR DERATED CURRENT, PM DEDICATED PV METER ® 11.17 AMPS MODULE SHORT CIRCUIT CURRENT. ® 17.45 AMPS DERATED SHORT CIRCUIT CURRENT [690.8 (A) & 690.8 (B)j. INV INVERTER(S) ,I:) I I Vlr �,4 A. 1�,/jlftJe Nti JJ AC r AC DISCONNECT(S) No, 9511! EEl _ g ; DC S iATE OF s 999 DC DISCONNECT(S) J l JJJJp�m,� �ORt���°''�'��: V��``�• J"''�`'/DNAL BOB COMBINER BOX ��/l/l/IIIIH1rt00 i ( EXPIRES: 2/28/2025 ABBREVIATIONS SIGNED:10/02/2023 F— 7 INTERIOR EQUIPMENT A AMPERE L __J SHOWN AS DASHED AC ALTERNATING CURRENT sunrun AFC ARC FAULT CIRCUIT INTERUPTE62 CHIMNEY AZIM AZIMUTH ENGINEER ADDRESS: 225 BUSH ST, SUITE 1400 SAN FRANCISCO. CA 94104 COMP COMPOSITION ATTIC VENT P:949-383-0993 DC DIRECT CURRENT FLUSH ATTIC VENT VICINITY MAP EC13007964 (E) .EXISTING PVC PIPE VENT 5208 TAMPA W BLVD, TAMPA, FL 33634 ESS ENERGY STORAGE SYSTEM u METAL PIPE VENT PHONE 0 FAX 0 EXT EXTERIOR CUSTOMER RESIDENCE: !NT INTERIOR - T-VENT BRIAN ONEIL MSP MASH SERVICE PANEL x �.,_ 36464 GARDEN WALL WY, SATELLITE DISH ZEPHYRHILLS, FL, 33541 (N) NEW NTS NOT TO SCALE FIRE SETBACKS TEL. (703) 673-8989 OC ON CENTER APN:04-26-21-0150-00700-0150 PRE-FAB PRE -FABRICATED HARDSCAPE PROJECT NUMBER: PSF POUNDS PER SQUARE FOOT —.- 802R-464ONEI PV PHOTOVOLTAIC — PL— PROPERTY LINE DESIGNER: (415) 580-6920 eX3 RSD RAPID SHUTDOWN DEVICE SOLAR MODULES LAUREN SAWYERS SCALE: NTS TL TRANSEORMERLEss (� SHEET TYP TYPICAL s REV NAME DATE COMMENTS COVER SHEET V VOLTS W WATTS_--' REV: A 10/2/2023 LAN LANDSCAPE ""_ TOPSPEED PAGE �/ ° I — POR PORTRAIT MOUNT ° . Template version- 4.0,93 SITE PLAN - SCALE = 1/16" = V-0" 0100 antly am1w.1 1� � 7 M WA SEMI E W o84923 STATE OF zu 0/011111MO Exp. 2128/2025 10/2/2023 James Matthew Walsh, State of Florida, Professional Engineer, License No. 84923 This item has been digitally signed and seated by James Matthew Walsh, PE on 10/2/2023 using a Digital Signature. Printed copies of this document are not considered signed and sealed and the SHA authentication code must be verified on electronic copies. .sull'ffun ENGINEER ADDRESS, 225 BUSH ST, SUITE 1400 SAN FRANCISCO. CA 94104 P. 949-383-0993 EC13007964 5208 TAMPA W BLVD, TAMPA. FL 33634 PHONE FAX 0 CUSTOMER RESIDENCE: BRIAN ONEIL 3III 6464 GARDEN WALL WY, ZEPHYRHILLS, FL, 33541 TEL. (703) 673-8989 &RILIA-- HRUJEU I NUMBEM: 802R-464ONEI DESIGNER: (415) 580-6920 ex3 LAUREN SAWYERS 1 ROOF INFO FRAMING INFO ATTACHMENT INFORMATION DESIGN CRITERIA Max OC Minimum Number of Mounts per Up -Slope Edge Max Landscape Max Portrait MAX DISTRIBUTED LOAD: 3 PSF Name Type Height Type Span Spacing Detail (Land sca pe/Portra it) Overhang Overhang SNOW LOAD: 0 PSF 01-101, WIND SPEED: 138 MPH 3-SEC GUST. AR-01 COMP SHINGLE - 2-Story 2X4 PRE -FABRICATED TRUSSES 51-111, 24" TOPSPEED, SEE DETAIL 2/2 1'- 6" TOPSPEED SNR-DC-30004 S.S. LAG SCREW AR-02 COMP SHINGLE - 2-Story 2X4 PRE -FABRICATED TRUSSES 5'- 10" 24" TOPSPEED, SEE DETAIL 2/2 1'- 6" 01-101, (4) #14 X 2.25" SS SEALING TOPSPEED SNR-DC-30004 WASHER WOOD SCREWS FULLY PENETRATING THROUGH WOOD D1 - AR-01 -SCALE: 1/8" V-0" INSTALLERS SHALL NOTIFY ENGINEER OF ANY DECK AZIM: 270' POTENTIAL STRUCTURAL ISSUES OBSERVED 14 E W PITCH: 22' PRIOR TO PROCEEDING W/ INSTALLATION. E 11 Si - MOUNT NUMBER FOR LEADING DOWNSLOPE \c EDGE SHALL MATCH REQUIREMENTS LISTED 845?3 ABOVE INSTALL PER TOPSPEED INSTALLATION MANUAL. CONTRACTOR MAY SUBSTITUTE SNAPNRACK — -a ', 2'-9" STATIE OF 44/ DECKTRACK MOUNTS (SNR DETAIL 0 " SNR-DC-00453) WITH A MAX OVERHANG OF 6" tOR10 T-6 is�/ONAL 3'-6" Exp. 2/28/2025 10/2/2023 3"-5" James Matthew Walsh. State of Florida. Professional Engineer, License No. 84923 V-1 This item has been digitally signed and sealed by James Matthew Walsh, PE on 10/2/2023 using a Digital 8'-9" 6-2" T-2" 12'-5"­----­­r- 6'-3" 10'-3" Signature. Printed copies of this document are not considered signed and sealed and the SHA authentication code must be verified on electronic copies. D2 AR-02 SCALE: 1/8" 1'-0"- AZIM: 90' AM Ift—_ PITCH: 23' ENGINEER ADDRESS 225 BUSH ST, SUITE 1400 SAN FRANCISCO. CA 94104 P. 949-383-0993 EC13007964 6'-3"­----1 3'-1 5'-9" 5208 TAMPA W BLVD, TAMPA. FL 33634 PHONED FAX 0 3' CUSTOMER RESIDENCE: — ----- BRIAN ONEIL T-6" 36464 GARDEN WALL WY, ZEPHYRHILLS, FL, 33541 T-6" TEL. (703) 673-8989 APN: 04-26-21-0150-00700-0150 3'-5" PROJECT NUMBER: 802R-464ONEI DESIGNER: (415) 580-6920 ex3 LAUREN SAWYERS SHEET LAYOUT REV:A 10/2/2023 PAGE PV-3.0 120/240 VAC SINGLE PHASE SERVICE METER #: NOTE: TOTAL PV BACKFEED = 50A <-- DUKE ENERGY 8357352 USED FOR INTERCONNECTION CALCULATIONS UTILITY GRID NEW 175A MAIN BREAKER (END FED) EXISTING EXISTING 200A 225A SUB MAIN PANEL (N) LOCKABLE DELTA ELECTRONICS: PANEL BLADE TYPE E10-TL-US FACILITY FACILITY AC DISCONNECT 9600 WATT INVERTER LOADS LOADS FEED -THROUGH 7� LUG ------------------ _�ILIIY UND (N) 50A PV SQUARE D LOAD RATED DO BREAKER AT DU222RB DISCONNECT WITH AFCI. OPPOSITE END 3R, 60A,2P APSMART TRANSMITTER OF BUSBAR 120/240VAC CONDUIT SCHEDULE # CONDUIT CONDUCTOR NEUTRAL GROUND 1 NONE (8) 10 AWG PV WIRE NONE (1) 6 AWG BARE COPPER 2 3/4" EMT OR EQUIV. (8) 10 AWG THHN/THWN-2 NONE (1) 8 AWG THHN/THWN-2 3 3/4" EMT OR EQUIV, (2) 8 AWG THHN/THWN-2 (1) 10 AWG THHN/THWN-2 (1) 8 AWG THHN/THWN-2 [EE�XISTINGE�XISTINIG �EXISTING EXISTING MODULE CHARACTERISTICS HANWHA Q-CELLS: Q.PEAK DUO BLK ML-G 10+ 405: 405 W OPEN CIRCUIT VOLTAGE- 45.34 V MAX POWER VOLTAGE: 3739 V SHORT CIRCUIT CURRENT: 11.17A SYSTEM SIZE: SYSTEM OPEN CIRCUIT VOLTAGE: SYSTEM OPERATING VOLTAGE: MAX ALLOWABLE DO VOLTAGE: SYSTEM OPERATING CURRENT: SYSTEM SHORT CIRCUIT CURRENT I JUNCTION BOX PV MODULES OR EQUIVALENT HANWHA Q-CELLS: Q.PEAK DUO BLK 01ML-G10+ 405 (24) MODULES (1) STRING OF (5) MODULES (1) STRING OF (5) MODULES (1) STRING OF (7) MODULES (1) STRING OF (7) MODULES L (24) APSMART RSD-S-PLC MODULE LEVEL RAPID SHUTDOWN DEVICES l) k Vlz� 4 No, 8 5111 "WE STATE OF Q- 0% top, ///1//0N7 '//mll I 00k" EXPIRES: 2128/2025 SIGNED: 10/02/2023 I e mpla teL versiorr_ 4 . 0, 93 TERMINALS ON LIFE AND LOAD SIDES MAY BE ENERGIZED IN THE OPEN POSITION LABEL LOCATION: INVERTER(S), AC/DC DISCONNECT(S), AC COMBINER PANEL (IF APPLICABLE). PER CODE(S): CEC 2019: 690.13(B), NEC 2017: 690A3(B) DO NOT RELOCATE THIS I OVERCURRENT DEVICE' LABEL LOCATION: ADJACENT TO PV BREAKER (IF APPLICABLE). PER CODE(S): CEC 2019: 705.12(B)(2)(3)(b), NEC 2017: 705.12(B)(2)(3)(b) I LABEL LOCATION: PHOTOVOLTAIC AC COMBINER (IF APPLICABLE). PER CODE(S): CEC 2019: 705.12(B)(2)(3)(c), NEC 2017: 705.12(B)(2)(3)(c) LABEL LOCATION: INVERTER(S), DC DISCONNECT(S). PER CODE(S): CEC 2019: 690.53, NEC 2017: 690,53 YTM LABEL LOCATION: MAIN SERVICE PANEL ADJACENT TO MAIN SERVICE LABEL LOCATION: BREAKER. UTILITY SERVICE METER AND MAIN PER CODE(S): CEC 2022: 705A2(B)(3)(2), NEC 2020: SERVICE PANEL. 705.12(B)(3)(2), NEC 2017: 705.12(B)(2)(3)(b), NEC 2014: PER CODE(S): CEC 2019: 705A2(B)(3), NEC 705.12(B)(2)(3)(b), NEC 2011: 705.12(D)(4), CEC 2019: 2017: 705A 2(B)(3) LABEL LOCATION: INSTALLED WITHIN T OF RAPID SHUT DOWN SWITCH PER CODE(S): CEC 2019: 690.56(C)(3), NEC 2017: 690.56(C)(3), IFC 2012: 605A1.1, IFC 2018: 1204.5.3, CFC 2019: 1204.5.3 LABEL LOCATION: INTERIOR AND EXTERIOR DC CONDUIT EVERY 10 FT, AT EACH TURN, ABOVE AND BELOW PENETRATIONS, ON EVERY JB/PULL BOX CONTAINING DC CIRCUITS. PER CODE(S): CEC 2019: 690.31(G)(3), 690.31(G)(4), NEC 2017: 690.31(G)(3), 690.31(G)(4) IFC 2012: 605.11.1.4 LABEL LOCATION: AC DISCONNECT(S), PHOTOVOLTAIC SYSTEM POINT OF INTERCONNECTION, PER CODE(S): CEC 2019: 690.54, NEC 2017: 690,54 im 0 ARRAY.SWITCH TO THE "OFF" LABEL LOCATION: ON OR NO MORE THAT 1 M (3 FT) FROM THE SERVICE DISCONNECTING MEANS TO WHICH THE PV SYSTEMS ARE CONNECTED. PER CODE(S): CEC 2019: 690.56(C)(1)(a), NEC 2017: 690.56(C)(1)(a) NOTES AND SPECIFICATIONS: 110,21(B), UNLESS SPECIFIC INSTRUCTIONS ARE REQUIRED BY SECTION 690, OR IF REQUESTED BY THE LOCAL AHJ. • SIGNS AND LABELS SHALL ADEQUATELY WARN OF HAZARDS USING EFFECTIVE WORDS, COLORS AND SYMBOLS. • LABELS SHALL BE PERMANENTLY AFFIXED TO THE EQUIPMENT OR WIRING METHOD AND SHALL NOT BE HAND WRITTEN. • LABEL SHALL BE OF SUFFICIENT DURABILITY TO WITHSTAND THE ENVIRONMENT • SIGNS AND LABELS SHALL COMPLY WITH ANSI Z535.4-201 1, PRODUCT SAFETY SIGNS AND LABELS, UNLESS OTHERWISE SPECIFIED. • DO NOT COVER EXISTING MANUF,4,CTURER LABELS. ���ttt6itlttfftlt No.851 = a o STATE OF OR At rft011111110" EXPIRES: 2/28/2025 SIGNED:10/02/2023 i emptate_ version-4.0. 93