Loading...
HomeMy WebLinkAbout23-7114City of Zephyrhills 5335 Eighth Street Zephyrhills, FL 33542 Phone: (813) 780-0020 Fax: (813) 780-0021 ELCMISC-007114-2023 Issue Date: 10/30/2023 REINSPECTION FEES: (c) With respect to Reinspection fees will comply with Florida Statute 553.80(2)(c) the local government shall impose a fee of four times the amount of the fee imposed for the initial inspection or first reinspection, whichever is greater, for each subsequent reinspection. Notice: In addition to the requirements of this permit, there may be additional restrictions applicable to this property that may be found in the public records of this county, and there may be additional permit required from other governmental entities such as water management, state agencies or federal agencies. a r - v rp--zi If Via tmi&s�'�A : 11 p I l�� 111 11 11 1 1 �� 1111 accordance with City Codes and Ordinances. NO OCCUPANCY BEFORE C.O. NO OCCUPANCY BEFORE C.O. CONTRACTOR SIGNATURE PE IT OFFICE *ERMIT EXPIRES IN 6 MONTHS WITHOUT APPROVED INSPECTION CALL FOR INSPECTION - 8 HOUR NOTICE REQUIRED P 2, OTECT- G-ARD-FR-0M-WFA.T-HER- 813,78OZO20 City of Zephyrhills Permit Application Fax-813-780-0021 Building Department Date Received It a a 1 4 a a a Phone Contact or PermiItttian I a ( 407 ) 308 0099 Owner's Name 11HAMS�AFAADA Owner Phone Number 0�9 97 - 52 1 3� Owner's Address Owner Phone Number Fee Simple Titleholder Name Owner Phone Number Fee Simple Titleholder Address JOB ADDRESS LOT # 1 30 ,ZEPHYR LAKES SUBDIVI ION SUBDIVISION PHASES 1 AND IG PARCEL (OBTAINED FROM PROPERTY TAX NOTICE) WORK PROPOSED NON CCNITR AOIDiALT SIGN DEMOLISH El INSTALL REPAIR PROPOSED USE SFR COMM OTHER TYPE OF CONSTRUCTION BLOCK FRAME STEEL DESCRIPTION OF WORK BUILDING SIZE SO FOOTAGE HEIGHT kCViEkIEX1LkIE EC14IEXAEXXJ1i ElEttl XCCILIECIEX EEXCI ittIEtIE1 CIE tXt1Ekr_XILkk kk1C Ekkttl BUILDING 1' 18,000.00 1 VALUATION OF TOTAL CONSTRUCTION =ELECTRICAL FS — — — — — — — — — — — AMP SERVICE PROGRESSENERGY = W.R.E.C. =PLUMBING =MECHANICAL S VALUATION OF MEC)­iANICAL INSTALLATION =GAS ROOFING SPECIALTY = OTHER SOLAR FINISHED FLOOR ELEVATIONS E= FLOOD ZONE AREA =YES NO COMPANY OMPANY SIGNATURE E=- Address ELECTRICIAN J A��'I"COMPANY VVINDMAR HOME FLORIDA, INC. SIGNATURE ,D =UA.J REGISTERED 4EGISTERED YIN FEE CURREN YYN 6753 KINGS OIN P l Address ORLANDO FL 32B19 License # PLUMBER COMPANY m. SIGNATURE E=== ;RZOISTCHED Address Licanseg MECHANICAL COMPANY E SIGNATURE === REGISTERED Y 1 N FEE Address E========== Ucens94 OTHER COMPANY SIGNATURE E=== RECaTEREO Address License 9 RESIDENTIAL Attach (2) Plot Plans; (2) sets of Building Plans; (1) set of Energy Forms: R-O-W Permit for new Construction, Minimum tan (10) working pays after submittal data Requtmd onsite, Construction Plaans, Slormwater Plans wi Silt Fence installed, Sanitary Facilities & 1 dumps' tcr, Site Work Permit for subdivisicn.suaw projects COMMERCIAL Attach (2) complete sets of Building Plans plus a Life Safety Page; (1) set of Energy Forms. R-C-W Permit for new construction. Minimum ton (10) working days, after submittal date. Required onsite, Construction Plans, $tormwater Plans w/ Silt Fence installed, Sanitary Facilities & I dumpster. Site Work Permit for all new projects. All commercial requirements must meet compliance SIGN PERMIT Attach (2) sets of Engineered Plans. —'PROPERTY SURVEY required for all NEW construction. Directions: Fill out application completely. Owner & Contractor sign back of application, notarized If over $2500, a Notice of Commencement is required, (A/C upgrades over $7500) — Agent (for the contractor) or Power of Attorney (for the owner) would be someone with notarized letter from mvner authorizing same OVER THE COUNTER PERMITTING (copy of contract required) Reroofs It shingles Sewers Service Upgrades A/C Fences (PIOUSLI'voylFociage) Driveways -Not over Counter if on public roadways -needs ROW 613-78MO20 City of Zelphyrridis Permit Application Fox-813-780-0021 Building Department NOTICE OF DEED RESTRIC'NOM The undersigned understands that this permit may be subject to 'daed* rest herions'which may us more restrictive than County regutaillons, Tice undersigned assumes responsibility for compliance Mil any applicable dead restrictions. UNLICENSED CONTRACTORS AND C014TRACTOR RESPONSISILME& if the seiner has fired a contractor or contractors to undertake work, they may be required to Us licensed in accordance with state and local regulations, if the contractor is not licensed as required by few, both the owner and contractor may be cited for a misdemeanor vibration tinder slate low. It the owner or intended contractor are uncertain as to w1rhe licensing requirements may apply for the Intended work, they are advised to contact the Pasco Country Building Inspection Division —Licensing Section at 727-847- 8009. Furthermore, if the owner has hired a Contractor or contractors, he is advised to have the contreamirls) sign portions of the 'contractor Block' Of this application for which they will be responsible. If you, as the ovater sign as the contractor,that may be an indication that he is not property licensed and is not eribiled to permitting privileges in Pasco County. TRANSPORTATION IMPACTfUTILITIES IMPACT AND RESOURCE RECOVERY FEES: The undersigned understands that Trando , orrahan impact Fees and Recourse Recovery Fees may apply to the construction of new buildings, change of use in existing buildings, or expansion of existing buildings, as specified In Pasco County Ordinance number SS-07 and SO-07, as amended, The undersigned also understands, that such fees, or, may he due, will be identified at the time of permitting. It is further understood that Transportation Impact Fens and Resource Recovery Fees must be paid prior to receiving a 'carlifloate of occupancy" or final power release. V the prqtol does not involve a certifiable of occupancy or final power release, the fees must be paid prior to permit issuance, Furthermore, ; Pasco County WaterlSower Impact fees are due, they most be said prior to permit asuanse to accordance with applicable Pasco County ordinances, CONSTRUCTION LIEN LMV (Chapter 713, Florida Statutes, as anterichad)z If valuation of work is 52,500M or more. I certify that I. the applicant, have been provided with a copy of the 'Florida Construction Lion LavV­Homecvmar's Protection Guide' prepared by the Florida Department of Agriculture and Consumer Affairs. It the applicant Is someone other than the 'owner'. I coolly that I have obtained a copy of the above described document and promise in good faith to deliver it to the "owner" prior to commencement, GONTRACTOR'SOWNER'S AFFIDAVIT. i certify that ell the Information in this application is accurate and that all work rvill be done in compliance with all applicable laws regulating construction, zoning and land development. Application is hereby made to obtain a permit to do wcur and installation as indicated, I Certify that no work or installation has commenced prior to issuance of a permit and trial all work will be performed to meet standards of all laws regulating construction, County and City, codes, zoning regulations, and land development regulations in the juradielion. I also certify that I understand than the regulations of other government agencies may apply to the intended work, and that it is my responsibility to identify what actions I trust :eke to be in compliance, Such agencies include but are not limited to: Department of Environmental Proteotion-Cypress Sayheads, Welland Areas and Environmentally Sensitive Lands, WaterANastarwater Treatment, Southwest Florida Water Management District -Welts, Cypress Beyheace, Welland Areas, Altering Watercourses, Army Corps of Engineers -Seawalls, Docks, Navigable WateRveys. Department of Health & Rehabilitative Services/Enviroomental Health Unit -Wells, Wastewater Treatment, Septic Tanks, US Environmental Protection Agency -Asbestos abatement. Federal Aviation Authority -Runways, I understand that the folloerne restrictions apply to the use of flit: Use of fill is not allowed in Flood Zone W" unless expressly permitted, if the fill material is to be used in Flood Zone 'A", it is understood that, a drainage plan addressing a compsnsattng volume" will be submitted at time a' permitting which is prepared by a professional engineer :barked by the State of Florida. if the fill material is to be used in Flood Zone 'A" in connection with a permitted building using stem wall construction, I ear tify that fill will be used onlytofill the area within the stem wall. if fill material is to be Used in any area, I certify that use of Such fill will not adversely affect adjacent properties. If use of fill is found to adversely affect adjacent properties, the owner may be cited for violating the conditions of the building pen -nit issued under the attached permit application, for lots less than one (1) acre which are elevated by fill, an engineered drainage plan is required, if I arn the AGFNT FOR T14F OWNER, I promise in good faith to Inform the owner of the parmilifing conditions set forth in this affidavit prior to commencing construction. I understand that a separate parrinit may be required for electrical work, plumbing, signs, wells, penis. air conditioning, gas, or other Installations not specifically included in the application, A pemili: issued shall be construed to be a 11frenter to process with the wadi, and not as authority to violate, cancel, alter, or set aside any provisions of the technical codes, nor shall issuance old permit prevent the Building Official from thereafter requiring a correction cf errors in plans, construction or violations of any codes. Every permit issued shall become invalid unless the work, authorized by such permit is Commenced ohhin six months of prinnit fsau2nce. or if wart, authorized by the Petri is suspended or abandoned :or a period of six (6) months after the time the work is commenced. An extension may be requested, in witmil, from the Building Offidat for a period not to exceed nicety (90) days and will demonstrate justifiable cause for the extension. if work ceases for ninety (Sill Consecutive days, the job is considered abandoned, WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RtSub fIWYOU R PAYING rJVICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YO TEND TO OBTAIN FINANCING, CONSULT FLORIDAJURAT (F.S. 117.0 ) 1 OINNER OR AGENT I CONTRACTOR 1, Epps �Ii go sw to.#r5-?,rr, id)tpf a this us 10 "1" alea by"'m qt��rn_ 'a 'h, A- �iisfa pL Coolly known to me or haililhavis produced to did or hasihave produced 7.11t _1F M.". _as rderitrltxifian. as Identification, VILL _Clary Public Notary public commission Commission Nome of No cry geed, a ntc ar stamps Name e diary ft pod, p fired r stood DIAN,,2� VADLER Commii H�i'17F_540 E'xpires I NS T R# 2023180985 OR 6K 10900 PG 526 Page 1 of 1 10/11/2023 01 :06 PM Ropt 2633310 Rec 10.00 DS G 00 IT, 0 00 Nikki Alvarez-Sowles, Esq., Pasco County Clerk & Comptroller 'Permit Number. Folioj'ParcaI IT) #: -50 Q2 Prepared by: jJaU VA�Lle V. _L___ Return to. ZWINN_04AR HOME FL0R'PA'iN-Q'---- 1753 !Ki sp2 to P@rkwe V Suite I II Orlando,T- State of Florida, The undersionea liereby gives- notice that improvement 0JI be made to certain real property, and in accordance with Chapter 713, Florida Statutes, the following information is provided in this Notice of Commencement. Description of property (legal desarlption of the property, and street address if available P8 84 PC 085 BLOCK 2 LOT 3N 8362 WHEAT STONE CAR 2. 40oneral dascrlptibn; 0" INSTALLAT14DN OF ROOF MOUNTED GRID -TIED PV SYSTEM 3, Owner information or Lessee information if the Lessee contracted for the nMprovem.qrr� Interest in Property QVVIN L- K �Aama and %ddress of fee simple titleholder (if different frorn Owner listed above) Name N/A Address_----- 4r Contractor 00W name VVINDMAR HOW Fi-ORIDAJNC. —Telephone Number —4,07-- -008- ,- 5, Surety (if applicable, a copy of the pay ment bond isattachead) Numi---r Address__ of 8. Lender Name N/A ---Telephone Ni,rnbem 7. persons vvithin the State of Florida designated by Owner upon 1,010m Tiotica.%cor other documuglts be served as proOded, by §71M3(1)(a)7, i5loefda Statutes, Name T egephneN C. in, addlflon to h5mseff or heFseif, Owner designatez thefollowing It recoM, a 00,01 of the Llen,W's ,40tica as provided in Florida Statutes. Name Telephone Number —--- Add, ess the exr)1ration date will be I year from the elate of MoOrdino �plration date of notice af comn9encO41fient unless ipi different date is specifted) WARNING To OIJVNER: ANY PAYMENTS MADE $Y THE 04WNER AFTER THEF EXPIRATION OF THE NOTICE OF COMMEMCEMENT ARE CONSIDE",D IMPROPER PAYMENTS UNDER CHAPTER 713, PART I, $�CTION 7I3. E3, FLORIDA STATUTES, AND CAN RE$ULT IN YOUR PAYfWG TWICE FOR IMPROVEMENTS TO YOUR PROPERTV. A NOTICE OP COMMENCEMENT MUST BE Riz-COROPO AND POSTED ONTHE JOB $ITE BEFORE. THE FIRSTINsPECT*N. Ir YOU iNTF;:N1D TO OfiTAIN FINANCING, CONSULT WITH POOR LaNDER OR AN.ATTOPNFY SeFOPF COMMEWNG WORK OR RECOR06NG YOUR NOVC16, OF COMMENCEMENT, Sigaat ire of owner 0~ Ltissoo, or Ownei'e or 0,F 0-a'si\ut4,,orized 111) V V rq C r1k Signatory T itle/Office I I — , ) z—� C day 0, o,2,3 The in5-ol,;mem ijvas ad,­ovvledgod bercre ri-�e V by lis Ps DAINER for Qf-sL�tzoit",' e7­ owiaor, tFjstee7t—twn,y'hf,,ct 77,i—mp^f pz)it/ on behplr of,.vhom?niur'1M,'0nt v,'Gq oxea�xteci N' Signature, oP Notary RIhV,, - $fate re' Florlde Print, .ppe, or swrTID onr­,Trni5sioned ri ie of Notary Public n. OWNIA V. ADLEIR Personailv Known Produced ID l, D S-'ai�e of D Type oI" ComrnM HH 178540 9/2.-3/2025 MI =ram F m. v, '. ���a pF is f r t of g Is I IT '`r} a tme a C1 Como cwydumt C't im fit onto or ek, So mcm rAwd b'1.i 0i3e' ..,. Pasco COL ur '3 :f Clerk �. CONTACT U& a, 7Nf yf u, , 6753 KINGSPONTE PARKWAY SUITE 1" 1, ORLANDO FL, 32819 USA TEL Tl 407-308-0099 'Re CD uj m m LOCATION MAP AERIAL VIEW PLAN VIEW _j Z 0 U- N COORDINATES: LAT 28.277225' LON -82.180274' COORDINATES: 28'16'38.0"N 82'10'49.0"W U-u. < W T_ 2 3: o c" 0- co N co W co N INDEX PERMITTING PLANNING NOTES O C-1 COVER SCOPE OF WORK: E-1 ELECTRICAL DIAGRAM & CALCULATIONS INSTALLATION OF GRID -TIED PHOTOVOLTAIC SYSTER',�',r. _3911­011,­­111_ 11)" E tq N S-1-1.1 SYSTEM LAYOUT q4F Non 86 S-2 SYSTEM LOCATION MAP SYSTEM DESCRIPTION a 0 S TATE OF S-3-6 STRUCTURAL DIAGRAMS & CALCULATIONS GRID -TIED PHOTOVOLTAIC SYSTEM:nb°RIxi (20 ) ENPHASE 107A-72-2-US MICRO -INVERTERS) 349W /01VAL D-1-6 DATASHEETS & LABELS (20 ) HANWHA Q-CELLS Q.PEAK DUO BLK-GlO+ 400 SYSTEM: REVISIONS (20 ) PHOTOVOLTAIC MODULES ARE CONNECTED INTO (20) MICRO -INVERTERS (20 ) MICRO -INVERTERS CONNECT IN TO (2) CIRCUITS OF ( 10, 10) MICRO -INVERTERS NUMER DATE DESCRIPTION WHICH FEED 2-P 240V 20A CIRCUIT BREAKERS DL5088 CHANGED CT LOCATION TO AS BUILT AND CHANGED OCPD FEEDER CONDUCTORS FROM 12/7(23 BRANCH BREAKER TO BAR- AS BUILT, TOTAL PHOTOVOLTAIC SYSTEM STC RATED ENERGY POWER PRODUCTION OF 8,000 DO WATTS 6,980 AC WATTS 1010.2023 11111­1­y INVERTER HAS MAXIMUM POWER POINT TRACKING (MPPT) INVERTER(S) CONFORMS WITH NEC 2020 SECTION 690.12 & C22.1-2015 RULE 64-218 RAPID SHUTDOWN OF PV SYSTEMS. MA <k >F.v INVERTER(S) CERTIFIED IEEE 1547 & CERTIFIED UL1741 M.ALVAREZ ALL ELECTRICAL EQUIPMENT INSTALLED ARE UL LISTED N_TS_ FLORIDA CODE SUMMARY COVER FIRE BUILDING ELECTRICAL FL FIRE PREVENTION CODE 7TH EDITION, FBC 2020, 7TH & IBC 2018 NEC 2017 & NFPA 70 NFPA-1 (2018) & NFPA-101 (2018) ASCE 7-16 C-1 NOTE: IN THE EVENT OF CONFLICTING REGULATIONS THE MOST RESTRICTIVE SHALL PREVAIL. _..... _..... _... _. ITEM DESCRIPTION: _.... CONTACT US PV MODULE RATINGS MODULE MAKE HANWHA Q-CEL s .. ... 6753 KINGSPOINTE '.., MODULE MODEL - --- -- --- Q PEAK- 400 1 PV MODULES, TYPE HANWHA Q-CELLS Q PEAK DUO BLK-G1 O+ 400 PARKWAY SUITE 111,'. -MAX POWER -- - - -- --- -400 w 2 MICROINVERTER: ENPHASE IQ7A-72-2-US (EQUIPPED WITH RAPID SHUTDOWN). ORLANDO FL, 32819 USA OPEN CIRCUIT VOLTAGE 45,30 V TEL: +^, 467-366-0093 MAX POWER POINT VOLTAGE 37. 13 v '.. _..... _._ _... 3.... ENPHASE Q CABLE MALE CONNECTOR (Q-12-10-240) 12 AWG DOUBLE INSULATED THHN/THWN-2 SHORT CIRCUIT CURRENT 11,14 a 4 1 ENPHASE RAW Q-CABLE (Q-12-RAW-300) PER BRANCH AND 196 BARE COPPER FOR '. engineering@windmarhome.com MAX POWER POINT CURRENT 10. 77 A GROUND IN V CONDUIT, ITEM MANUFACTURER MODEL LISTING 7 COMPLIANCE 5 JUNCTION BOX 6' x 6" SUITABLE FOR WET LOCATIONS (UL ENVIRONMENTAL RATING TYPE 4X). PC MODULE Q CELL 40OW u B 2#10 THHN PER BRANCH AND 1#6 THHN FOR GROUND IN 1" CONDUIT TO CARRY BRANCH CIRCUIT CONDUCTORS TO LOAD CENTER. NOTE: INSTALL OUTDOORS PVC EXPANSION FITTING «± INVERTER ENPHASE IQ7A UL WHERE NEEDED. ALL DISCONNECTS ENPHASE DC&.AC UL B1 B2 63 34 B5''.. B6 B7 B8 B9 B_10 ALL OVERCURRENi ENPHASE DC & AC UL 7 ENPHASE IQ COMBINER BOX 4C WITH IQ ENVOY METER (X2-IQ-AM1-240-4C) 125A BUS RATING PROTECTION 1201240 VAC WITH 2 BREAKERS 20Al2-P & 1 BREAKER (15A OR 10A)/2-P FOR IQ ENVOY r-SEC CERTIFICATION Q CEu 40OW INSTALLED BY MANUFACTURER. NUMBER ENPHASE 147A RV 16-0106A ' 2 3 NOTE: IQ ENVOY METER ENABLES WEB -BASED MONITORING AND CONTROL, AND PROVIDES ' PRODUCTION METERING AND OPTIONAL CONSUMPTION MONITORING. THIS METER IS -'-" - ®y INCLUDED IN THE LIST OF ELIGIBLE METERS FROM THE CALIFORNIA ENERGY COMMISSION. ;,, -..... 8 3#6 THEN CU AND 1#6 THHN CU FOR GROUND IN V CONDUIT. I07A 960A FUSED DISCONNECT FOR PHOTOVOLTAIC AC DISCONNECTlRAPID SHUTDOWN DISCONNECT -. --- ® "" Al A2 A3 A4'.. A5''. A6 A7 A8 A9 A10 SERVICE ENTRANCE RATED WITH 40A FUSES:23 - 1.45A x 1.25 = 36.25A = 40A (OCPD) - -- NOTE: DO NOT INSTALL NEUTRAL -TO -CASE BONDING GREEN SCREW, THIS PREVENTS C3 - OBJECTIONABLE CURRENT AS PER NEC 250,6. 06 fy Ct 1 TOTAL PHOTOVOLTAIC SYSTEM STC RATED DC POWER PRODUCTION OF 8.000 'A p- � / In 2. INVERTER HAS MAXIMUM POWER POINT TRACKING (MPPT). RODE- LEVEL EL 10 EXISTING UTILITY METER. � � Cy)3. INVERTER MEETS REQUIREMENTS OF 3-P POWER. - - - - - -- 4. INVERTER MEETS IEEE 1547, 5. INVERTER M!-ETS UL1741 11 EXISTING RESIDENCE 150A MAIN BREAKER, 6. ALL ELECTRICAL EQUIPMENT INSTALLED ARE UL LISTED 7. FBC ADMINISTRATION COD`c5 NOW IN EFFECT NEC 2017, FRC 2020' 'E-' FBC ADMINISTRATION' TION' ALL ELECTRONICS SOIAD PANELS AND ASSOCIATED ELECTRICAL B�( II)( 6 - 9 15. 12: LOAD SIDE TAP INTERCONNECTION PER NEC 705.12 Z 1 b) EQUIPMENT TO BE INSTALLED ARE ILL L15TE0' 16 I SYSTEM AUTOMATIC OPERATION - 13: EXISTING MAIN SERVICE PANEL WITH 2O0A BUSBAR RATING. LL �- _j ' NOTE: PROTECTION OF MSP BUS BAR PER NEC705.12 B 2 3 b 120% RULE: 200A BUS RATING x 1.2 CO Q _3 t. GRID POWER IS PRESENT PHOTOVOLTAIC SYSTEM FEEDS 1'HE LOAD AT DAY TIME ` 12, ( )( }(, ){ ) - 2. GRID POWER IS LOST, PFiOTOVOLTAIc SYSTEM AUTOMATICALLY DISCONNECTS FROM - - 150A MAIN BREAKER = 90A AVAILABLE FOR SOLAR aYsLU THE GRIT) :. 15A 3, PHOTOVOLTAIC SYSTEM WILL AUTOMATICALLY RESUME FEEDING PO�- 'dVER TO THE 7 -- .. ' STAND D. WHEN AND THERE IS ENOUGH SUNLIGHAND FREQUENCY Is RESTORED (IEEE 20a ..e : -� --10 ` 14 EXISTING GROUNDING ELECTRODE CONDUCTOR. ICA znA 40A• 15'. EXISTING INTERIOR DISTRIBUTION SUBPANEL WITH 225A BUSBAR RATING. SCHEDULES A ' 1soA 11' d' scALE. NTS PRODUCTION "; 16 200A FUSED DISCONNECT WITH 150A FUSES NEMA 3R FOR INTERIOR DISTRIBUTION SUBPANEL. h�! CYi LU ' THIS IS REQUIRED TO COMPLY PER NEC 240.21 DUE TO THE DISTANCE BETWEEN MSP AND CO N _...... CT -- 150A' arA'P vA.''r -..at :.13; INTER[OR DISTRIBUTION SUBPANEL EXCEDiNG 25 FEET OF CONDUIT AND TO COMPLY WITH 13 ^ 705.12(B)22d 1)(b) TO PROTECT SUBPANEL AND FEEDER CONDUCTORS FROM POTENTIAL OVERLO EEIiSS. -- 171 3#310 THHN CU AND 1#6 THHN CU FOR GROUND IN 2" CONDUIT. c~.1 -. 8 8 17 '19i 181 EXISTING FEEDERS CONDUCTORS �. ve o r .. s„' 7 19' NEW ENPHASE ENVOY CONSUMPTION CURRENT T RANSFORMERS ATI R ,7� 1 r I NOTE: BOTH THE FEED -THROUGH CONDUCTORS AND THE CONDUCTORS OF ALL EXISTING LOAD AAu u c , a c 1 t r BREAKERS IN THIS PANEL MUST PASS THROUGH THE CONSUMPTION CTs TO MONITOR THE , 1, rT ti.. wore - 14... CONSUMPTION OF ALL LOADS x or AF r co�pstn N, oa GROUND LEVEL INSIDE RESIDENCE '® NOTES. a a a a 11 ,<< N<, -IN , ,Ill 1,r:e " mE • ALL CONDUITS AND RACEWAYS APPROVED PER METHOD NEC 2017 AND FBC 2020. - THE EVENT OF CONFLICTING REGULATIONS THE MOST RESTRICTIVE SHAL N$ '4 IN 4 �rP wu AD CAL-LAT-A a e ��, _ PREVAIL e- c'FII�..� N�. r� cco _,c Co, .xAN.,e N, rx.s� _ o` `' • ALL EQUIPMENT IS SUITABLE FOR OUTDOORS INSTALLATION AND RATED FOR IV -- --- - -- - -- - - THE SIZE OF ALL CONDUCTORS BASED ON THEIR AMPACITY FOR AN AMC TEMPERATURE OF 194-F (9O`C) WAS TAKEN FROM NEC TABLE 13.310 15(B)(2)( X , SYSTEM DATA Voltage Drop Calculation Temperature Correction ex TOTAL W: 8,000 WATTS DC / 6,980 WATTS AC MSP BUSBAR RATING: 200A o 0 &°. EE OF8 � TOTAL PV MODULES: 20 PHOTOVOLTAIC MODULESa Formula: NEC 2017 - TABLE 310.1.5(B)(A) PV MODEL: HANWHA Q-CELLS Q.PEAK DUO BLK-G10+ 400E FOirrlUEa: INVERTER: ENPHASE IQ7A-72-2-US MICROINVERTER �� � , (� z VD = (2"L`IrnaX*k) I BATTERY: NONE Imax = SYSTEM RISER WIRING DIAGRAM EQUIPMENT LOCATION D Temperature Rating- RACK SYSTEM: UNIRAC SCALE: NTS _..... _. Ambient Ternoor.., Correction FrAtO(5 BECAUSE THE SERVICE NEUTRAL CONDUCTOR PROVIDES THE EFFECTIVE GROUND -FAULT CURB ENT PATH TO THE POWER SUPPLY [250.24(C;/) YOU DON'T WAVE "O INSTALL AN L = Length of Wire > Ambient Temperature: 31-35 ( C NOTE: ENGINEER CERTIFIES THAT THIS PLAN COMPLIES WITH 107.3-5 FBC. EQUtPMENTGROL)NDINGCONOUCTORWITHNPVCCONDuiTCONTAtNINGSERV'oE-ENTRANCECONDUCTORS[25a-t42(A)fl)AND352.60Ex2). «r�= DL5088 1FITTINGS, . THREADED TERMINATE METAL RACEWAYS TO METAL ENCLOSURES BY THREADED HUBS ON ENCLOSURES (IF MADE WRENCH TIGHT). k - Wire material % lempefature Rating of Conductor G 96 - 2 HREADLESS FITTINGS TERSNNATE METAL RACPAJAYS To METAL ENCLOSURES BY THREADLESS FITTINGS/IF MADE TIGHT) - ImaX = Current ➢ Ambient Temperature: 87-95 - F IMPORTANT NOTE: NEC 705.12 3. OTHER LISTED DEVICES. THESE INCLUDE BONDING --TYPE LOCKNUTS, BUSHINGS, WEDGES, OR BRUSHINGS'NITH BONDING JU.IPERS. 10.10.2023 ' WHERE TWO SOURCES, ONE A UTILITY AND THE OTHER AN INVERTER, ARE LOCATED AT OPPOSITE ENDS OF A BUSBAR THAT CONTAINS LOADS, THE SUM OF 125%OF - --- - - .. THE INVERT'ERO) OUTPUT' CIRCUIT CURRENT AND THE RATING OF THE OVERCURRENT DEVICE PRO TEC TING THE BUSBAR SHALL. NOT EXCEED 120% THE AMPACRY DESIGN TEMPERATURE: 109"F HISTORICAL RECORDED HIGH TEMPERATURE (FLORIDA.). FOR CONDUIT INSTALLATION MORE THAN 6.7° ABOVE ROOF, DOES NOT REQUIRE 2 = Constant OF THE SUBPAR. THE BUSBAR SHAt..L BF .SIZED FOR THE LOADS CONNECTED IN ACCORDANCE'WITH ARTICLE 22Q, A PERMANENT WARNING LABEL SHALL BE APPLIED ADDITIONAL TEMPERATURE ADDED. ACCORDING TO NEC TABLE 310.15BIZ Xj FOR TEMPERATURE 105 TO 113'. USE TEMPERATURE CORRECTION FACTOR 87 MULTIPLE FACTOR IN Results: TO THE: DISTRIBUTION EQUIPMENT ADJACENT TO THE BACK -FED BREAKER FROM 'THE INVERTER THAT DISPLAYS THE FILL 1.0AING OR EQUIVALENT WORDING TABLE 310.15CLIU #10 THNN-2 RATED 40 AMP (NEC TABLE 310.15(9)16) X .87 = 34 8 AMPS. FOR 8 CARRYING CONDUCTORS IN SINGLE CONDUIT ADJUSTMENT FACTOR: AT% (NEC: MA WARNING: - D = Conductor Properties TABLE 31n.15@)(3)Ln 0.7x3TEA=2436AMPS "ea,�"v i : /q TC=37.76A INVERTER OUTPUT CONNECTION; DO NOT RELOCATE THIS OVERCURRENTDEVICE. BONDING .MIDCLAMPASSEMBLY M. ALVAREZ ,DAL.c: THE WARNING VGNGX OR LABELS) SHALL COMPLY AllTH 110.21(B). - -- --- -- --- -- STAINLESS STEAL MIDCLAMP POINT"S..2 PER MODULE.. PIERCE MODULE FRAMEANODI7_ATION TO BOND MODULE T'O MODULE THROUGH CLAMP. Conductors Q.T.S. Conductors EXCEPTIGN EQUIPMENT WTI MULTIPLE AMPACITY BUS13ARS OR CENTER FED PANELBOARDS ARE NOT ADDRESSED BY THIS PROVISION- a SERRATED FLANGE NUT BONDS STAINLESS STEEL CLAMP TO STAINLESS STEEL EEL T-BOLT - s re:n r ReSultS: � p NEC 2017 - Table 310.1.5(B)(17) Allowable NEC (BUS RATING) X L2 - (MAIN BREAKER) - 120% RULE 3. SERRATED i'-BOLT HEAD PENETRATES RAIL. ANODPATION TO BOND T-BOL:i', NUT, CLAMP, AND MODULES TO GROUNDED SO RAIL. VD1.04 V Ampac ties of Single -insulated Conductors V Rated Up to and ludeding 2,000 Suits In Free THE NEC GIVES YOU THE CHOICE OF FOUR METHODS FOR ENSURING ELECTRICAL -CONTINUITY AT SERVICE EQUIPMENT. SET/ICE RACEA.YS, AND SERVICE CROSS SECTIONAL AREA CALCULATION: : ELECTRICAL DIAGRAM & A,, Based on Ambient Temperature CONDUCTOR ENCLOSURES (250.92(B): CALCULATION CROSS SECTIONAL AREA OF 4�, THHN - 0.2028 SQ.4N.: [-y 1. BONDING JUMPERS. BOND METAL PARTS TO THE SERVICE NADI RAL CONDUCTOR. THIS REQUIRES A MAIN BONDING JUMPER (250.241CR AND 250 281. BECAUSE CROSS SECTIONAL AREA OF V TUBE 0 79 SO IN FIV_II - R10,79) esults: i Cable 46 AWG THWN- 2 - Capacity 105 A THE SERVICE NEUTRAL CONDUCTOR PROVIDES THE EFFECTIVE GROUND-'rAULT CURRENT PATH TO 1'HE POWER SUPPLY F250,241C), YOU DON'T HAVE TO C 2028 (0 79) x 100 = 25.7 f <40% under 90 C INSTALL AN EQUIPMENT GROUNDING CONDUGTOR WITHIN PVC CONDUIT CONTAINING SERVICE -ENTRANCE CONDUCTORS [250, 142JPAD and 352 60 e,, 21, CALCULATIONS ...0 e,'Al -- VD% = OM % : Conduit V FVC Schedule 40 - Capacity 6 2 THREADE:DLESS Ff,7INGS TERMINATE METAL RACEWAYS TO METAL ENCLOUSURES BY THREADED HUBS ON ENCLOUSURES OF MADE WRENCHTIGH 1) FILL y�iI..CULATIONS NOTE: Conductors 3. THREADEDLF_SS FITTINGS, TERMINATE_ METAL RACEWAYS TO METAL ENCLOUSURES BY THREADLESS FILLINGS (IF MADE TIGHT). ALL FILL CALCULATIONS ON THIS DESIGN HAVE BEEN DONE IN COMPLIANCE WITH NEC312,8. '. E _ 1 4. OTHER LISTED DEVICES. lTHESE INCLUDE BONDING -TYPE LOCKNUrS, BUSHINGS, WEDGES, OR BUSHINGS WITH BONDING JUMPERS- LOCATION MAP COORDINATES: LAT 28.277225' , LON-82.180274' t WIN ,NTACT US: 6753 KlNGSPONdTE PARKWAY SUITE 111, ORLANDO FL, 32810USA TEL +1407-30E-00% INDEX PERMITTING / PLANNING NOTES 0 C— 6 COVER SCOPE OF WORK: PkOPkiETaPv RIGrT9 OFnuAN^- CbNCEvi E Al,SLP'n T11 E-1 ELECTRICAL DIAGRAM & CALCULATIONSINSTALLATION OF GRID -TIED PHOTOVOLTAIC SYSTE b S-1-1.1 SYSTEM LAYOUT z, 4ae G ' ar3cs 17 I A— S-2 SYSTEM LOCATION MAP SYSTEM DESCRIPTION S-3-6 STRUCTURAL DIAGRAMS & CALCULATIONS GRID -TIED PHOTOVOLTAIC SYSTEM: S-rAl (20 ) ENPHASE IQ7A-72-2-US MICRO -INVERTERS) 349W .' ( 20 ) HAN A Q-CELLS Q.PEAK DUO BLK-G10+ 400 D-1-6 DATASHEETS & LABELS SYSTEM: REVISIONS (20 ) PHOTOVOLTAIC MODULES ARE CONNECTED INTO (20) MICRO -INVERTERS D 1 (20 ) MICRO -INVERTERS CONNECT IN TO (2) CIRCUITS OF ( 10, 10) MICRO -INVERTERS $a NUMBER DATE �ESCRIPTIOPt _. ..._ .. WHICH FEED 2-P 240V 20A CIRCUIT BREAKERS oLSosa or Tz TOTAL PHOTOVOLTAIC SYSTEM STC RATED ENERGY POWER PRODUCTION OF 8,000 CC WATTS / 6,980 AC WATTS 9.2T2023 INVERTER HAS MAXIMUM POWER POINT TRACKING (MPPT) INVERTERS) CONFORMS WITH NEC 2020 SECTION 690.12 & C22.1-2015 RULE 64-218 RAPID SHUTDOWN OF PV SYSTEMS, MA INVERTER(S) CERTIFIED IEEE 1547 & CERTIFIED UL1741 M. ALVAPZEZ ALL ELECTRICAL EQUIPMENT INSTALLED ARE UL LISTED I_ FLORIDA CODE SUMMARY kk _ COVER l _ _ FIRE BUILDING ELECTRICAL FL FIRE PREVENTION CODE 7TH EDITION, FBC 2020, 7TH & IBC 2018 NEC 2017 & NFPA 70 NFPA-1 (2018) & NFPA-101 (2018) ASCE 7-16 d 1 NOTE: IN THE EVENT OF CONFLICTING REGULATIONS THE MOST RESTRICTIVE SHALL PREVAIL. PV MODULE RATINGS MODULE MAKE HAN MODULE MODEL iMAX POWER 40OW OPEN CIRCUIT VOLTAGE = 45.30 V MAX POWER POINT VOLTAGE = 37.13 V SHORT ClRCUfF CURRENT 11.14A I MAX POWER POINT CURRENT = _ 10.77A ITEM MANUFACTU REP MODEL LISTING t COMPLIANCE ,PVMODULE Q-CELL UL 'INVERTER ENPHASE IaFA­­UL ;ALL DISCONNECTS ENPHASE UL ALLOVERCURRIENT W PROTECTION ENPHASE DO ILAC UL CERTIFICATION Cl-CELL 400vv 'NUMBER ENPHASE 107A RV-16-0,106A ULU L:j 7 107A 1, TOTAL PHOTOVOI SYSTEM STC RATED DO POWER PRODUCTION OF 8,000 W. 2� EV E VERT R WE =jTA R SIMIUM ER PONT T�Kllu T OUnSW 3. ENTS OF 3-P PG (MPPT). g. NV MEETS 6LE 1 54'Irf. 6. ALL ELECTRICAL EQUIPMENT INSTALLED ARE UL LISTED, 1, I&NA - A 1jaITST I ENETERCH12W & EFFECTELN%�Il I F LEETRF L M IFT OrTATL S, SOLAR PAN S 4SSONATIFIE 6 Pit EQUIPMENT TO BE INSTALLED ARE UL LISTED.' SYSTEM AUTOMATIC OPERATION 2., GRID RO%� I IsP SjP7A OHOVOOLVICAF TFo AT[CTHAEA DAOCAEC IJE FROM THE GRID_ 3- P ,VTOVOLTAIC SYS M LRAUTRATICALLY R$SUMF FEEDINGfOWER TO T ID VHEN E PROPER OPE7LG ID LTACIE -I) REQUENCY IS ESTORED ORE STANDARDS) AND THERE IS ENOUGH SUNLIGHT. MUM SCALE:NTS -T-1:ER T- PATE PEftC NfCT,3PC11M1T1nNSNIN1­M ­1P IF "'­E Wuo S- sc m, C,1 k­-INP ­11c .R NOU OR lO M 1Q T gA I T o81& II �c ,_AxT�R 11I 99MIOMMIRMH= Formula: NEC 2017 - TABLE 310.15(B)(A) Formula: VD Irnax D Temperature Rating Ambient Temperature Correction Factors L = Length of wire Ambient Temperature: 31-35 (- C) k zz Wire material > Temperature Ratingof Conductor; 0.96 'max = Current > Ambient Temperature; 87-95 c F 2 oc Constant Results: D = Conductor Properties TC =3T76A Results: Conductors NEC 2017 - Table 310,15(g)(17) Allowable VD 1.04 V Ampackies of Single-In'ufated Conductors Rated Up to and Including 2,000 Volts in Free Air, Based on Ambient Temperature Results: i > Cabie #6 AWG THWN- 2 - Capacuty 105 A VD% 0,86 % under 9TC > Conduit I'PVC Schedule 40 - Capacity 6 conductors SCALE: NTS IMPORTANT NOTE: NEC 706.12 WHERE W40 SOURCES. ONE A UTILITY AND THE OTHER AN INVERTER. ARE LOCATED AT OPPOSITE ENDS OF A BURSAR THAT CONTAINS LOADS. THE SUM OF 126% OF THE INVERTERISY OUTPUT CIRCUIT CURRENT AND THE RATING OF THE OVERCURRENT DEVICE PROTECTtNG THE SUSBAR SHALL NOT EXCEED 1211% THE AMPACITY OF THE SUSSAR. THE BUSBAR SHALL BE SIZED FOR THE LOADS CONNECTED IN ACCORDANCE WITH ARTICLE 220. A PERMANENT WARNING LABEL SHALL BE APPLIED TO THE DSTRIBUTION EQUIPMENT ADJACENT TO THE BACK -FED BREAKER FROM THE INVERTER THAT DISPLAYS THE FOLLOWING OR EQUIVALENT WORDING: WARNING: INVERTER OUTPUT CONNECTION; 00 NOT RELOCATE THIS OVERCURRENT DEVICE, THE WARNING SIGNS) OR LASEL(Sy SHALL COMPLY WITH 1 IP21 ISL EXCEPTION: EOUIPhRNT WITH MULTIPLE AMPACITY BUSSARS OR CENTER FED PANELBOARDS ARE NOT ADDRESSED BY THIS PROVISION. NEC: (BUS RATING) X 1.2 - (MAIN BREAKER) - 120% RULE THE NEC GIVES YOU THE CHOICE OF FOUR METHODS FOR ENSURING ELECTRICAL CONTINUITY AT SERVICE EQUIPMENT, SERVICE RACEAYS, AND SERVICE CONDUCTOR ENCLOSURES (250.92(8): 1. BONDING JUMPERS. BOND METAL PARTS TO THE SERVICE NEUTRAL CONDUCTOR, THIS REQUIRES A MAIN BONDING JUMPER [250.24(B) AND 260.281. BECAUSE THE SERVICE NEUTRAL CONDUCTOR PROVIDES THE EFFECTIVE GROUNDFALI CURRENT PATH TO THE POWER SUPPLY (250.24(C), YOU DON'T HAVE TO INSTALL AN EQUIPMENT GROUNDING CONDUCTOR WITHIN RVC CONDUIT CONTAINING SERVICE -ENTRANCE CONDUCTORS 1250.142ONO) and 352.60 .. 21, 2 THREADEDLE SS FITTINGS. TERMINATE METAL RACEWAYS TO METAL ENCLOUSURES By THREADED HUBS ON ENCL OUSURES OF MADE WRENCHTIGHT), 3, THREADS DLESS FITTINGS, TERMINATE METAL RACEWAYS TO METAL E NCLOUSURES BY THREADLESS FITTINGS (IF MADE TIGHTI, 4. OTHER LISTED DEVICES. THESE INCLUDE BONDING -TYPE LOCKNUTS . BUSHINGS. WEDGES. OR BUSHINGS WITH BONDING JUMPERS. C1, PV MODULES, TYPE: HANWHA Q-CELLS Q_PEAK DUO BLK-GIO+ 400 MICROINVERTER: ENPHASE 101 (EQUIPPED WITH RAPID SHUTDOWN). ENPHASE Q CABLE MALE CONNECTOR (Q'12-10-240)12 PING DOUBLE INSULATED THHNfTHWN-2 I ENPHASE RAW C-CABLE (0-12-RAW-300) PER BRANCH AND 1#6 BARE COPPER FOR GROUND IN V CONDUIT, JUNCTION BOX 6" - 6" SUITABLE FOR WET LOCATIONS (UL ENVIRONMENTAL RATING TYPE 4X). 2#10 THHN PER BRANCH AND W THHN FOR GROUND IN V CONDUIT TO CARRY BRANCH CIRCUIT comdu&CRSTO LOAD CENTER. NOTE: INSTALL OUTDOORS PVC EXPANSION FITTING WHERE NEEDED. ENPHASE IQ COMBINER BOX 4C WITH IQ ENVOY METER (2-10-AMI-2404C) 125A BUS RATING 120/240 VAC WITH 2 BREAKERS 20A/2-P & I BREAKER (15A OR 10I FOR IQ ENVOY INSTALLED BY MANUFACTURER, NOTE: 10 ENVOY METER ENABLES WEB-SASED MONITORING AND CONTROL, AND PROVIDES PRODUCTION METERING AND OPTIONAL CONSUMPTION MONITORING. THIS METER IS INCLUDED IN THE LIST OF ELIGIBLE METERS FROM THE CALIFORNIA ENERGY COMMISSION. 3#6 THHN CU AND 1#6 THHN CU FOR GROUND IN V CONDUIT. Ji 60A FUSED DISCONNECT FOR PHOTOVOLTAIC AD DISCONNECTIRAPID SHUTDOWN DISCONNECT SERVICE ENTRANCE RATED WITH 40A FUSES: 20 x 1.45A x 1.25 = 36.25A = 40A (OCPD) NOTE! DO NOT INSTALL NEUTRAL -TO -CASE BONDING GREEN SCREW, THIS PREVENTS OBJECTIONABLE CURRENT AS PER NEC 250.6. EXISTING UTILITY METER. EXISTING RESIDENCE ISOA MAIN BREAKER. LOAD SIDE TAP INTERCONNECTION PER NEC 70612(BlI �3J EXISTING MAIN SERVICE PANEL WITH 200A BUSBAR RATING, NOTE: PROTECTION OF MSP BUS BAR PER NEC705.12(B)(2)(3)(b) - 120% RULE: (200A BUS RATING x 1,2 - 150A MAIN BREAKER = 90A AVAILABLE FOR SOLAR CONTACTUS: 6753 KINGSPOINTE PARKWAY SUITE 111, ORLANDO FL, 32819 USA TEL +1 407-3SO099 enjneerhg&ndnRrhome.com EXISTING GROUNDING ELECTRODE CONDUCTOR. EXISTING INTERIOR DISTRIBUTION SUBPANEL WITH 225A BUSBAR RATING. NEA 3R FOR INTERIOR DISTRIBUTION SUBPANEL. 200A FUSED DISCONNECT WITH 150A FUSE240211 THIS IS REQUIRED TO COMPLY PER NEC 240.21 DUE TO THE DISTANCE BETWEEN MSP AND INTERIOR DISTRIBUTION SUBPANEL EXCEDING 25 FEET OF CONDUIT AND TO COMPLY WITH 701 2 PROTECT SUBPANEL AND FEEDER CONDUCTORS FROM POTENTIAL OV RL(WdV)(b) TO 3*3/0 THHN CU AND 1#6 THHN CU FOR GROUND IN 2" CONDUIT. I Lu EXISTING FEEDERS CONDUCTORS '191 NEW ENPHASE ENVOY CONSUMPTION CURRENT TRANSFORMERS. I -- NOTE: BOTH THE FEED -THROUGH CONDUCTORS AND THE CONDUCTORS OF ALL EXISTING LOAD BREAKERS IN THIS PANEL MUST PASS THROUGH THE CONSUMPTION CTsTO MONITOR THE CONSUMPTION OF ALL LOADS NOTES: • ALL CONDUITS AND RACEWAYS APPROVED PER METHOD NEC 2017 AND FBC 2020. 1 "1.1- T1, INI IN THE EVENT OF CONFLICTING REGULATIONS THE MOST RESTRICTIVE SHALL 4 a'y I . PREVAIL. ALL EQUIPMENT IS SUITABLE FOR OUTDOORS INSTALLATION AND RATED FOR 90 THE SIZE OF ALL CONDUCTORS BASED ON THEIR AMPACITY FOR A14 TEMPERATURE OF 194"F (90°C) WAS TAKEN FROM NEC TABLE B.310.15(BX2 S .1 �AT El -C F 19le BECAUSE THE SERVICE NEUTRAL CONDUCTOR PROVIDES THE EFFECTIVE GROUND -FAULT CURRENT PATH TO THE POWER SUPPLY [250.24(C)),YOU DON'T HAVE TO INSTALL AN EQUIPMENT GROUNDING CONDUCTOR WITHIN PVC CONDUIT CONTAINING SERVICE -ENTRANCE CONDUCTORS [250.142(A)(1) AND 362.60 EX 21. 1. THREADED FITTINGS. TERMINATE METAL RACEWAYS TO METAL ENCLOSURES By THREADED HUBS ON ENCLOSURES (IF MADE WRENCH TIGHT). 2. THREADLESS FITTINGS. TERMINATE METAL RACEWAYS TO METAL ENCLOSURES BY THREADLESS FITTINGS (IF MADE TIGHT), 3. OTHER LISTED DEVICES. THESE INCLUDE BONDING -TYPE LOCKNUTS, BUSHINGS, WEDGES, OR BRUSHINGS WITH BONDING JUMPERS, DESIGN TEMPERATURE: 1WF HISTORICAL RECORDED HIGH TEMPERATURE (FLORIDA). FOR CONDUIT INSTALLATION MORE THAN 6,7' ABOVE ROOF, DOES NOT REQUIRE ADDITIONAL TEMPERATURE ADDED. ACCORDING TO NEC TABLE 310.15(B)(2)(9) FOR TEMPERATURE 105 TO 113: USE TEMPERATURE CORRECTION FACTORS-, MULTIPLE FACTOR IN TABLE 310.15(B)I6. #10 THWN-2 RATED 40 AMR (NEC TABLE 310.15M)16i X ,87 - 34,8 AMPS, FOR 8 CARRYING CONDUCTORS IN SINGLE CONDUIT ADJUSTMENT FACTOR: 70% (NEC TABLE 310.15(8)(3)fa) OT x 34,8A - 24,36 AMPS BONDING MIDCLAMP ASSEMBLY 1, STAINLESS STEAL MIDCLAMP POINTS, 2 PER MODULE, PIERCE MODULE FRAME ANODII To BOND MODULE To MODULE THROUGH CLAW. 2. SERRATED FLANGE NUT BONDS STAINLESS STEEL CLAMP TO STAINLESS STEEL T-BOLT. 3. SERRATED T-BOLT HEAD PENETRATES RAIL ANODIZATION TO BOND T-BOLT, NUT, CLAMP, AND MODULES TO GROUNDED SM FAIL, CROSS SECTIONAL AREA CALCULATION: CROSS SECTIONAL AREA OF % THHN - 0.2028 ScN,; CROSS SECTIONAL AREA OF I'TUBE. 0,79 SOON, FILL % (0.2028 / 0.79) x 100 = 25.7% , 40% FILL CALCULATIONS NOTE: ALL FILL CALCULATIONS ON THIS DESIGN HAVE BEEN DONE IN COMPLIANCE WITH NEC3122. SYSTEM DATA TOTAL W: 8,000 WATTS DO / 6,980 WATTS AC MSP BUSBAR RATING: 200A TOTAL PV MODULES: 20 PHOTOVOLTAIC MODULES PV MODEL: HANWHA Q-CELLS Q, PEAK DUO BLK-GIO+ 400 INVERTER, ENPHASE IQ7A-72-2-US MICROINVERTER BATTERY: NONE RACK SYSTEM: UNIRAC DL5088 9.27.2023 MA M-ALVAREZ N.T.S, ELECTRICAL DIAGRAM & CALCULATION Lmm SOLAR PANELS: 20 x HANWHA 40OW (PV - ARRAY) INVERTERS: 20 x 10 7A - 240VAC (INVERTER EFFICIENCY: 95%) MOUNTING TYPE: UNIRAC EVALUATION OF DESIGN LOCATION: FLORIDA. USA RECORD LOW TEMPERATURE: 35,00 'F AVERAGE HIGH TEMPERATURE: 78,00 'F RECORD HIGH TEMPERATURE: 98.00 'F TECHNICAL DATA PV PEAK POWER: 6,980 Wp NUMBER OF PV MODULES 20 NUMBER OF INVERTERS: 20 MAX. DO POWER 40OW MAX. AC POWER 349VV GRID VOLTAGE: 240V NOMINAL POWER RATIO: 95% PV ARRAY NUMBER OF PV MODULES: 20 NUMBER OF INVERTERS: 20 PEAK POWER OUTPUT 400VVO MPP PV VOLTAGE 37.13V GO PV VOLTAGE 45.30V MIN. DO VOLTAGE (240V GRID) 33, OV MAX. PV VOLTAGE 40V MAX. DC VOLTAGE (INVERTER) 58V MAX. CURRENT OF PV 11, 14A MAX. DO CURRENT 10,77A PV & INVERTER COMPATIBILITY PV ARRAY & TYPE OF INVERTER ARE COMPATIBLE. THE NOMINAL POWER RATIO (MAX, DO POWER OF THE INVERTER DIVIDED BY THE PEAK POWER) IS WITHIN THE RECOMMENDED RANGE (80% -120%). LEGEND 36" FIRE CODE OFFSET INFPA 1, 2015, Ch. 11) EXISTING UTILITY METER EXISTING MAIN SERVICE PANEL NEW COMBINER BOX AC NEW 6OA/4OA FUSED AC PV DISCONNECT/ RAPID SHUTDOWN DISCONNECT NEW 20OA/I 50A FUSED PV SYSTEM AC DISCONNECT EXISTING INTERIOR DISTRIBUTION SUBPANEL JUNCTION BOX SUITABLE FOR WET LOCATIONS R ROOF VENT LOCATIONS RIDGE VENT LOCATIONS ROOF ACCESS POINT ROOF TYPE: ASPHALT SHINGLE TOTAL ROOF AREA: 3182.60 SOFT TOTAL PHOTOVOLTAIC AREA 422.40 SOFT ROOF AGE: <5 YEARS PRESSURE ZONE: 1 & 2 MEAN ROOF SLOPE 4.6/12 TOTAL MODULES: 20 TOTAL ROOF MOUNTS: 42 TOTAL POINT OF CONNECTIONS PER MODULE: z RACKING SYSTEM: UNIRAC ALUMINUM RAILS PER MODULE: 2 TILT 1 21' AZIMUTH 1:181 w-m-d-011111 SCALENTS sm NTACTUS: 6753 KINGSPONTE PARKVVA,Y SUITE I I 1, ORLANDO FL, 32819 USA TEL: I 407-308-GM I DL5088 _d -927,2D-23-- MA M.ALVAREZ -11E N.T.S. SYSTEM LAYOUT Raw R�j EW 200A FUSED DISCONNECT WTH150A FUSES FOR INTERIOR SUBPANEL EXISTING METER/ NEW =60A/40A FUSED AC PV 'Y'm'mm 11 MAINSERVICE PANEL EXISTING INTERIOR DISTRIBUTION SUBPANEL CAC CAC kC. 112. SAC ok CRC C C -R, "RC 'F' AG At: OR' C AC CAG DA'l OZ . .. ........... - ------ N NEC 690.56 (B) AND NEC 705.10 [JZ')je*jyjg m SYSTEM LOCATION MAP SCALE: NTS EXISTING INTERIOR DISTRIBUTION SUBPANEL I EXISTING METER h MAIN SERVICE PANEL ODA FUSED DISCONNECT WITH I 50A FUSES FOR INTERIOR SUBPANEL NEVV 60A/40A FUSED AC PV OISCONNECTIRAPID SHUTDOWN NEW ENPHASE r-r----COMBINER BOX 'ONTACT US: 6753 KINGSPOINTE PARKWAY SUITE 111, ORLANDO R, 32819 USA TEL: +1 407-3W00% C) If) W m a z 0 u- I-- - u. U) w < F- 0 —1 C14 (D N ce) W co N 0- T� .ARICu U 7, ­ ;L ;088 9.27.2023 MA M.ALVAREZ N.T.S. SYSTEM LOCATION MAP S-2 A, 12" A, r3a'-16 X I' SS SERRATED T-BOLT Y HEX FLANGE NUT 2 7- UNIRAC FLASHKIT PRO INSTALLATION DETAIL SCAUE:NrS Lag pA1­ IMIhd­4 c.pxicies (ibs) ypi.1 1-b., (ASD) I N-e O4 MIS 23r i69 E`8 Pr Ldg­!c fw, - W 255 Us wen P 0!3 Sac 717, ns 26, T­ .�9s 769 V, 117 W� L ,."A HSR xnd HID 0 Sb E65 2. 211" otllei11, 1 . UNIRAC ROOF ATTACHMENT LAG SCREW elff" x 3%j' MANUFACTURER: ECOFASTEN SOLAR/ MCDEL1 8-LB-5/16X3-1/2 47,1.. L ARRAY WIND LOAD CALCULATIONS SOLAR PANELS TOTALAREA(SOFT) I 422.40 NOTE BASIC WIND SPEED MPH) 1711 RAILS SPAN FOR UNIRAC STANDARD SM RAIL IS ALWAYS GOING TO BE BUILDING HEIGHT (FT) 6-01 INSTALLED AT A MAXIMUM OF 4FT. EXPOSURE CATEGORY C _7� ROOF PITCH 4At12 - jr- jv S M W wpgg ZULRM " SPAN TABLE-Non-Exposedi 11" & M 0 U NI; .................. ............................ ........................ .......... ------- ................ II5 S6 5 711,I-T T!� �-ILII T"II T!T 1 1SMLT 11L Sds- m W, 5 M, W WHO WHO so sm VA W SIAItWHO WHO a 16q ITT WET IT!SM W SM WWH) SMAO WHwO "6,,IT W W sm SMAID WHI) WHO WffD 70 WLT SMLT T SMLT W SrA 9fe4 W SNi4c, 9MD WHO SMAID I A SMLT st"LT 514LT 5kTLT SMLT sm W SFrSM Alldfti* Add WlAdd R*f' Add95JF` T11 M SMLT WLT WLT WIT SKI 914 sm SM W Add Rx,- AddAsil' AINF.4' Add RAI` 155 $,MIT 'FAIT W11 1111T W 111, Im A. Ik,1* 11111,11 461,111 Add11 I Add 11,1 A. 40 I- -IT WLT SMLT SILT SM W Add Mil- Add R.A- Ada Reif` Add A.11- Add Raft' Add It.9- Add RAO 166 WIT WIT SMLT WLT SKI Add W* Aghl fW� AddfW- Add RadAdd R+D,- Add R,10' AddfaP AdiaRaif* ti 170 511ILT 'SMLT WET SALT SM I MdA.V Add W Add Rat" AsdRW Add W?� Add KW Add PH- A dsR� 175 WLT SMLT WLT W Add said* Adskaaef* Add Fail* Add40i' AT14R4,P Adst At Red' AddPW* AId9TsV* ISO WIT WLT MIT SMLT $14 Add Ravi' Add Pal' A4dkW Ad4IR.3w Add Rail*'Rail*'AhdRafl- Add Rad � AdORM* 155 SMLT SMLT SMLT SM SM Add W- Add UOAdd trait' AddA.4- Add ftf" AM Ikal* AMZII�'. Add Rail°. 160 WIT WIT SPAILT W Add Rsff- Add Rail" AsW A." Addfta- A46 W' Add W• Add W' Add flag* Add PW- i65 SIVILT WIT SM SM Add W* AddftJ* Add W'* AddRa" Add RBA* Add Kir' AAd Rod* A46 Rod* 4d6fw* 17a SM WIT W SM Add RAI* Add ftV Add PW� Add P.W° ADdftfl" Add UI- Ad6ftIO' Add Anil" Add Ralf"1 75 SMLT SMLT SM W Ado tljjj* AddRailt Add FW4- Add Rla- A44 R.A* Add R.0- Add"f' Add R.4- Add Reif{ Not R.0 1P.-N, 1ed on ASCE 7-16, B.ildlng Risk r­gory it, F-w­TTo-wTPta-Y6.S7, M­ Root H*Aghtf I-Ift, scum C-Ifid- 5, M 15,pr, ­iz: miS .,d ."d ­&l. t. r..f ,Iom d'.. d 67,n,­d2 md, k--f 1.1-9 �M­T�d 1. L f1st, M.'11"Ad - lh_ trp 1!'P, 1a&' of to to ASCE 7-16 AS OF 2021 11111Oo" UNIR" Pb-- GU_ CTLA- ONE FOP -As NOTE: 7 I2 k, i.-- L_ SS Lag BT,t < -/16' CALCULATIONS WERE PERFORMED AND PERTAIN TO UNIRAC SUPPLIED PARTS ONLY. THIS CERTIFICATION EXCLUDES THE MODULE, 2e� Lbz M", -n-, DO,,h 1 CONNECTIONS TO THE E BUILDING STRUCTURES, AND EFFECTS ON THE BUILDING STRUCTURE COMPONENTS. THIS ANALYSIS WAS DEVELOPED ASSUMING A MEAN BUILDING HEIGHT OF LESS THAN OR EQUAL TO 30 FEET. ALL INFORMATION, DATA AND ANALYSIS M., 1­1 SvT,�g ,­Fd PA- Bdd 4 CONTAINED WITHIN ARE BASED ON, AND COMPLY WITH THE FOLLOWING: Mr­ble �a St -A, Fe,eat Aga LIA adt F„" O,A st,e,tT, ­.ty 1. 2018 INTERNATIONAL BUILDING CODE, BY INTERNATIONAL CODE COUNCIL, INC., 2017 2. 2020 FLORIDA BUILDING CODE, BY INTERNATIONAL CODE COUNCIL, FBC 20203TH EDITION. 3 ASCEISEI 7-16 MINIMUM DESIGN LOADS FOR BUILDINGS AND OTHER STRUCTURES, BY ASCE, 2015 4. 2015 ALUMINUM DESIGN MANUAL, BY THE ALUMINUM ASSOCIATION, 2015 ALLOWABLE LOAD: 56 PSF NOTE INSTALL MID CLAMPS BETWEEN MODULES AND END CLAMPS AT THE END OF EACH ROW OF MODULES. ALUMINUM RAILS SHOULD ALWAYS BE SUPPORTED BY MORE THAN ONE FOOTING ON BOTH SIDES OF THE SPLICE. NOTL - V­ RA,`, cNA4-iLE`A­ 70 vOr G, FA, sp- 16' Z-1 --1, 11 1 _-, 'A L T­ g, ;t7 MCDULF CAT, 0(NOT EXCLED 257, 0- MUDUU 010Te LANDSCAPE ORIENTATION %01E "Al:111u,' -L -ID 'Al� 111 79 InT _SEEF 331, O' PAL SPAIN T Wrenches and 1�p IIEI He O-_DtTLT C­FTLE,,-,P PORTRAIT ORIENTATION IN _H GCj N0 EYC� ED 2� VCD,�L� ENT, YEAS+; TEM­JS .. AC,tiG SYSTEM ANCHORAGE SCALE:NTS VW-h St. 1/4' Hardware @0% 7/l 6 ------- 1 1 *10 SAT Hardware 0 9116, #12 Hardware 40 5/16' 1 10 Torques are not designed for use with wood connectors Stainless steel hardware can seize up, a process called gaffing. To significantly reduce its likelihood: 1. Apply minimal lubricant to bolts, preferably Anfi-Seize commonly found at auto parts stores Z Shade hardware prior to installation, and 3. Avoid spinning stainless nuts onto bolts at high speed. �7] ASIDE 7-16 VELOCITY PRESSURE 16'MEAN ROOF HEIGHT ZONE i = 33.7 PSF ZONE 2 = 56.6 PEP ZONE 3 = 56B PSF (NO MODULES) i 6753 KINGSPOINTE 30'MEAN ROOF HEIGHT ZONE I = 517 PSF ZONE 2 = 75,3 PSF PARKWAY SUITE 111, ZONE 3 = 753 PSF (NO MODULES) ORLANDO FL, 32819 USA OZ10 = 0.00256*KZ*KZT*KD*V`2 WHERE: i TEL +1407,308-0099 QZ10 = ASIDE 7-16 VELOCITY PRESSURE EVALUATED AT MEAN ROOF HEIGHT (PSF) KZ = VELOCITY PRESSURE EXPOSURE COEFFICIENT KZT = TOPOGRAPHIC FACTOR KID = WIND DIRECTIONALITY FACTOR V =BASIC WIND SPEED (MPH} FROM ASCE 7-16 MAPS REFERRED TO AS ULTIMATE WIND SPEED MAPS IN 2012 IBC. k VELOCITY PRESSURE: QZIO = 0.00256*0+85*1,0*0.85*175^2 NTMA2 = 56.6 PSF - CALCULATIONS FOR 1SMEAN ROOF HEIGHT DESIGN WIND PRESSURE P = OZIO*G*CF = 56,6*0,85*0,70 = 317 PSF AS AN EXAMPLE, FOR AN ARRAY HAVING AN AREA OF 1,115 -SOFT.. THE TOTAL UPLIFTING (RESULTANT) FORCE ACTING ON THE ARRAY WOULD BE 33.7 PSF X 1,115 SOFT. = 37,575.5 LB, KNOWING THIS RESULTANT FORCE,THE DESIGN ENGINEER CAN NOW DETERMINE THE NUMBER OF ATTACHMENT POINTS AND THE SIZE OF THE MOUNTING HARDWARE NECESSARY TO SAFELY CARRY THIS LOAD. 0% LIVE LOADS LIVE LOADS ASSOCIATED WITH PHOTOVOLTAIC SYSTEMS ARE USUALLY ASSUMED TO BE DISTRIBUTED UNIFORMLY AND ARE SMALL, ON THE ORDER OF 4 PSF OR LESS. ATTACHMENT INSTALLATION GUIDELINES 1. LOCATE ROOF RAFTERS AND SNAP CHALK LINES TO MARK THE INSTALLATION POINT FOR EACH CS ROOF ATTACHMENT. 2 DRILL A 7/32NPILOT HOLE AT EACH ROOF ATTACHMENT. FILL EACH PILOT HOLE WITH SEALANT. L0 3. ADD A "U-SHAPED" BEAD OF ROOF SEALANT TO THE UNDERSIDE OF THE FLASHING WITH THE < < W 2) OPEN SIDE OF THE "U" POINTING DOWN THE ROOF SLOPE. a 0 Z 4. SLIDE THE ALUMINUM FLASHING UNDERNEATH THE ROW OF SHINGLES DIRECTLY UP SLOPE FROM THE PILOT HOLE. 0 _j EL 5. ALIGN THE INDICATOR MARKS ON THE LOWER END OF THE FLASHING WITH THE CHALK LINE ON THE ROOF TO CENTER THE RAISED HOLE IN THE FLASHING OVER THE PILOT HOLE IN THE ROOF.LL LL 6. FASTEN L-FOOT AND FLASHING INTO PLACE BY PASSING THE LAG SCREW AND PRE -INSTALLED STAINLESS STEEL EPDM WASHER THROUGH THE L-FOOT EDPM GROMMET, AND THE RAISED HOLE IN THE FLASHING, INTO THE PILOT HOLE IN THE ROOF RAFTER, 7. DRIVE THE LAG SCREW DOWN UNTIL THE L-FOOT IS HELD FIRMLY IN PLACE. NOTES: Pq W oo N 1, THREAD MUST BE EMBEDED IN THE SIDE GRAIN OF A TRUSSES OR OTHER STRUCTURAL MEMBER INTEGRAL WITH THE BUILDING STRUCTURE, 2 LAG BOLTS MUST BE LOCATED IN THE MIDDLE THIRD OF THE STRUCTURAL MEMBER, 3. THESE VALUES ARE NOT VALID FOR WET SERVICE, ILI 4. THIS TABLE DOES NOT INCLUDE SHEAR CAPACITIES. IF NECESSARY, CONTACT A LOCAL ENGINEER TO SPECIFY LAG BOLT SIZE WITH REGARD TO SHEAR FORCES. 5. INSTALL LAG BOLTS WITH HEAD AND WASHER FLUSH TO SURFACE (NO GAP). DO NOT OVER -TORQUE. FFTNR157- RITITS ­­ CONCE- WITHDRAWAL DESIGN VALUES FOR LAG SCREW CONNECTIONS SHALL BE MULTIPLIED BY APPLICABLE ADJUSTMENT FACTORS IF NECESSARY. SEE TABLE 10.0.1 IN THE AMERICAN WOOD ks ITT, ie COUNCIL NDS FOR WOOD CONSTRUCTION. -jQ­' AT ITI I SOLARMOUNT UNIVERSAL AF STANDARD SYSTEM COMPONENTS ------ OA INSTALLATION GUIDE: Z", n W 0 RAIL: SUPPORTS PV MODULES. USE AT LEAST TWO PER ROW OF MODULES. PRODUCT# 320246M RAIL SPLICE: NON STRUCTURAL SPLICE JOINS, ALIGNS, AND ELECTRICALLY BONDS RAIL SECTIONS AIL. FORMS EITHER A RIGID OR THERMAL E TtONS INTRO SINGLE LENGTH OF P EXPANSION JOINT, 41N. LONG, PRE -DRILLED. T E F PRODUCT# 303019M KV SELF -DRILLING SCREW. (NO. 12 x W) USE 4 PER RIGID SPLICE OR 2 PER EXPANSION P JOINT. STAINLESS STEEL. SUPPLIED WITH SPLICE, IN COMBINATION WITH RIGID SPLICE, y PROVIDES RAIL TO RAIL BOND. A 0 L-FOOT: USE TO SECURE RAILS THROUGH ROOFING MATERIAL TO BUILDING IT STRUCTURE. REFER TO LOADING TABLES OR U-BUILDER FOR SPACING. 0 L-FOOT T-BOLT: (a/� "x %") USE ONE PER L-FOOT TO SECURE RAIL TO L-FOOT STAINLESS STEEL. SUPPLIED WITH L-FOOT. IN COMBINATION WITH FLANGE NUT, PROVIDES DL5088 ELECTRICAL BOND BETWEEN RAIL AND L-FOOT. SERRATED FLANGE NUT (-%"): USE ONE PER L-FOOT TO SECURE AND BOND RAIL TO 9,27.2023 L-FOOT. STAINLESS STEEL SUPPLIED WTH L-FOOT MODULE ENDCLAMP: PROVIDES BOND FROM RAIL TO ENCLAMP. PRE -ASSEMBLED MA ALUMINUM CLAMP. SUPPLIED WASHER KEEPS CLAMP AND BOLT UPRIGHT FOR EASE OF ASSEMBLY, PRODUCT#:302021C M-ALVAREZ MODULE MIDCLAMP: PRE -ASSEMBLED CLAMP PROVIDES MODULE TO MODULE ANC -I-.. MODULE TO RAIL BOND. STAINLESS STEEL CLAMP AND T-BOLT. PRODUCT#:3=27C : MICROINVERTER MOUNTING BOLT: PRE -ASSEMBLED BOLT AND NUT ATTACHES AND AA BONDS MICROINVERTER TO RAIL. WASHER AT BASE KEEPS BOLT UPRIGHT FOR EASE OF Seal Bond, 500 STRUCTURAL DIAGRAM ASSEMBLY. PRODUCT*008013S CALCULATIONS NOTE: (POSITION INDICATOR) T-BOLTS HAVE A SLOT IN THE HARDWARE END CORRESPONDING TO THE DIRECTION OF THE T-HEAD. c SEAL BOND 500 S-3 SOLARMOUNT 0"UNIRAC war", all W-11 SO 3'":RM 4.,sNe is ,s h pro sis`#L:~?,tis choice for resi „�ent'ai V irnw E1 rk@ r iEvery aspect ct of- he C ' applications. system r is des r.,sniedr f an ( sier i §-t r }r sta' a on experience, Ie, SOLAR 17I4 r� iN i ,p (co sy��44let solution '{!,ult'� 3 f'�_, vtd.@I ',3 �E f.i ��.„. �„r d.$ JK .,3SF 5,>C„[ �'„ f:. (J4 4. �tS 3"s.AlIS,B�i,. �€ I�s E.F I �i.tF°� 4a`s Seb �e� „t `,h k.4�S�EI.eI S,s-� 3.fi A:E.a k ¢ L^�,a„`. ((1��gt on }i ni s I cl nnps S SRO 6! C y3 � �€, 70 a c .; fgio and �` warranty, asa r p � Not �k, '�lr3 Ek ��"t7I E4As ��€€6�:i�I�iU� bz 14�4E[�.1 �.� �fl.� PRO, �.i�w system v.:#�+�sl §...,Y� s..f S..s`_i ;34,S�Sk €§�tj�t„E f..S'!f [f �¢SLf Lt��{r �� 2L4�i�$�=•,sl�. t only �g� �; Og N "gas* { install, , t best -in Err � Y fi e €her r attractive y ` 1 E r P .1;±¢y €?Ai�14 S.,S <sP'`''� 4.I,! 1,is! -Ew s;@.�`i 4.€1.r u; ?a€�?..� i the tE eti(.4�.J c... ;>sr Lt.€'.i;y ,rfaK,. THE PROFESSIONALS"' CH011-110E NOW FEATURING . H PRO U, t rC_'It` S0 EEnTU?,r+ 6 �4 & EAR. TECHNGEUcr -wr W WITH UNIVERSAL MIDCLAMPS Accommodates 3Om-5immmodule frames One tool, one -person installs are here! 214111RIM11111k,H111101111131 ill hill] V11FA1111111i Is IN go ,ONTACTUS: 6753 KINGSPOINTE PARKWAY SUITE 111, ORLANDO FL, 32819 USA TEL: +1407-308.0099 eazina�raindmazh4rne.carr Et tat y I ',oL,;088 9, 27.2}23 MA tom. AL_VAREz N.T,S. DATASHEETS LABELS I s�e�r No i S-4 a In 'M ME qULAe* BONDING CONNECTION GROUND PATHS- 11-1- OF S M M 0 U N T 11, N S-1iAli, L L A T110 N ipai U I D E "I P A G E IONDING MIDCLAMP ASSEMBLY Stainless steel Midctamp points, 2 per modu p 'I ierce module frame anodization to do module to module through cLamp. Serrated flange nut bonds stainless steel cLa to stainless steel T-boft lllct"01--V�7I !nra7A"v'-8=' to bond T-boLt, nut, clamp, an7dmoluALes grounded SM raiL. to stainless steeLT-boLt Serrated T-bolt head penetrates rail anodization to bond T -bolt, nut, and EndcLamp to grounded SM rail BONDING RAIL SPLICE BAR GBonding Hardware creates bond between 0 bar and each rail section Muminurn splice bar spans across rail gap to create rail to roil, bond, Rail. on at least one side of splice will be grounded. Hex nut with captive lock washer bonds meta[ microinverter fi.ange to stainless steel T-boft Serrated T-bolt head penetrates rail anodization to bond T-bolt, nut, and L-footto grounded SM rail Serrated T-bolt head penetrates rail anodization to bond T-boft, nut, and L-foot to grounded SM rail RACK SYSTEM GROUND WEEB washer dimples pierce anodized rail, to create bond between rail and lug jo-t-, Solid copper wire connected to tug is routed to provide final system ground connection, Lim 6753 KINGSPOINTE PARKWAY SUITE 111, ORLANDO FL, 32819 USA TEL: +1 4G7-30&wGM LU 1-11-Ty A�1� 8-ITTEV -1 . .... ..... W7, u,- 4- N DL 5088 9.27,2023 MA M.ALVAREZ -Z. N, T. S. W a MIN g 00 ag/ ION 1 IMF, % lu LAR S M ri ,,, BONDING CONNECTION GROUND PATHS M'' n s I low M U U INST LLAtA ION GUIDE'l PAGE A When removing modutes for repLacement or system maintenance, any module Left in place that is secured with a bonding MidcLamp wiLL be properLy grounded. If a moduLe adjacent to the end moduLe of a row is removed or if any other maintenance condition Leaves a moduLe without a bonding mid clamp, a temporary bonding connection must be instaLLed as shown * Attach Rsco SG134 to wall of raiL * Attach ILsco SGB4 to module frame * InstaLL solid copper wire jumper to ILsco Lugs ELECTRICAL CONSIDERATIONS SOLARMOUNT is intended to be used with P modules that have a system voLtage Less than equal to 1000 VDC. For standard system groundin a minimum 10AWG, 1050C copper groundin conductor should be used to ground a 1000 VD system, according to the National ELectric Cod I (NEC). It is the instaL[er's responsibility to check Loc, codes, which may vary. See below for i nterconnectio information. )I INTERCONNECTION INFORMATION There is no size Limit on how many SOLARIVIOUNT & PV modules can be mechanicaLLy interconnected for any given configuration, provided that the 6753 KINGSPONTE PARKWAY SUITE I 11, ORLANDO FL, 32819 USA t3 LU TEL: +1 407-308-OM installation meets the requirements of appLicabLe! building and fire codes. 11 Ell 411, A 'I. IE -T l.- ati- GROUNDING NOTES 7, ry The installation must be conducted in *-prdance- with the National Electric Code (NEC,'lafld authority having jurisdiction. Please refer 't6,`,,.'t'hbsQ,., resources in your Location for required groundih quantities specific to your project. oh v ,&L`5088 The grounding/ bonding components may overhang 9,21,123 parts of the array so care must be made when walking around the array to avoid damage. M. ALVAPEZ N.TS. Conductor fastener torque values depend on DATASHEETS conductor size. See product data sheets for correct LAS&OLS torque values. S-6 4­1 j 6 1 Pi Q CELLS is the first solar module manifacturer to pass the most comprehen- sive quality programme in the industry: The new "Quality Controlled PW of the independent certification institute TOV Rheinland, `-OW"C' i v "'NEA, l'iw H C 0 Y Optimal yields, whatever the weather with excellent low -light and temperature behavior, Hfl­ P Long-term yield security with Anti LID Technology, Anti PID Technology', Hot -Spot Protect and Traceable Quality Tra.Q"a. Al"It- A" High ech aiurninunn alloy frame, certified for high arrow (5400Pa) and wind loads (400OPa), PEI U�E_ A, LF 'riVES Inclusive 25 -year product warranty and 25-year linear performance warranty". APT test comtio-s acco,ciing 30 F.C/-S 62804-�,2CI5, meti-od A ( li5oc /. 96h) Seeda, 5,eet cn rear "a, nfl,,maU , 41 least 98A, G� rtr)-,irte power di�­g -sry,-ar. Thereafter max 0 5 A 't least 93.5% BE ------------------ d,�gradat sr, pc -rear, C, r18 Oc.er "o t„ 10 V _EE T -E, a a T At e a s 6, % c f I GM 8 P,C'Ne' Jp �3 a 6 9 a r sa 25 years 0 s ax der's w,t',i- Teasu--me-t toierelrc es 8 wal raries fr a,=dvcis V*h ou x , BE lle vz,,ranty rz­rts of the Q CEL-S z-� Tyecauu a refc,rrarce uoc* ivaaa,,ce 3orld,tions in ­B, L,,ompb, son io S -C coroi:b� f2l, - 0, W/91) ---------- TEMPERATURE COEFFICIENTS [%/K1 % Y KI 0.34 N t,11 OT rzi if�, PRO.L 11. DESIGN V 1000 (,EC},'130 (UL) lA DCI 20 hbsl 75i3600DaV55(2 660Pa) trblelft`3 113 (5400,-a}/84 (s:000 Pa) See f-sta ati-cl Kyanue Cw,, iJ" A L t F" III All' 0 N S A N 0 C"ElF T F b.r1� E S THE IDEAL SOLUTION FOR: Q,,7,i-y,­­',,:­ TIAI��c, Pc,olicp or, j x,�t No aj,a3lb 0.dh}, 1 (C E 0,_-,cw ."0 - " q c 69 eedo't ti b"'i C ngs Zlll� 0.27 o 4 cr X ts YPE -/O*F up to lK-'F l--40'7 up to 85'C) DL5088 9,27,2023 MA 1 M.ALVAREZ 76.4 n 43,3iq 68.0in ',656 Cis 24 24 32 '940rr- 1!0Cmrn 122Cnm 751�g pcIetls Celle' N. T, S. -S dues DATASHEETS Note: rnzttrl at a inalfc-Jons mus, be tcl oaaad See the, -eollatlon and operti-i-g r.raruar C, --cs lac° cur l8cf,ninal ser,;ce, oepartfrentfcr rifcanon cri aCo,o,ed nsta;Vaticq a,,A use of LASELS is Aroduc',_ j ay Henwhe 0 CELLS Ameril-al lnc. a Engineered in Germany CELLS AS0 Spectrum ce,e, 06'e. Sure 14C0. it, is CA 92618, USA I "Er- -1949 748 59 96 1 n,-lu,ry,?_bus q-cefls co I 'I'l,"Fa vvrv,w q,-Ce s 's D-1 E:T•N pe.eaton.Com General Duty Cartridge Fuse Safety Switch Dimensions: • Height: 7 IN • Length: 6.41 1 • Width: 8.4 IN I Notes:Maximum hp ratings apply only when dual element fuses are used. 3-Phase hp rating shown is ,2 grounded B phase rating, UL listed. Warranties: - Eaton Selling Policy 25-000, one (1) year from the date of installation of the Product or eighteen (18) months from the date of shipment of the Product, whichever occurs first, Specifications: • Type: General Duty/Cartridge Fuse • Amperage Rating: 60A ® Enclosure: NEMA 3R • Enclosure Material: Painted galvanized steel • Fuse Class Provision: Class H fuses • Fuse Configuration: Fusible with neutral • Number Of Poles: Two -pole • Number Of Wires: Three -wire • Product Category: General Duty Safety Switch • Voltage Rating: 240V Supporting documents: • Eatons Volume 2-Comrrnercial Distribution • Drawing Dataset • Eaton Specification Sheet - DG222NRB Cartridge Fuse General -Duty Safety Switch W. dmm=l Product Description • 30-600A • Suitable for service entrance applications unless otherwise noted • Fusible and non -fusible switches are 100% load break and 100% load make rated • The continuous load current of fusible switches is not to exceed 80% of the rating of fuses employed in other than motor circuits. Non -fusible switches are 100% fully rated • 200-600A features K-Series design • Horsepower rated • Fusible and non -fusible switches. Single -pole S/N through four -wire; 120/240, and 240 Vac • With Class R fuses, switches may be used on systems capable of delivering 100,000A rms symmetrical Note: Plug fuse switches are not service entrance rated. • Bolt -on hub provision. Provided for general -duty switches in a NEMA 3R enclosure. See Page V241- 14 for selection For residential and commercial applications. Suitable for light -duty motor circuits and service entrance, Switching Devices Safety Switches Description Page Product Overview ............................ V2-TI-2 General Duty V2-T1-25 Standards and Certifications ................. V2-T1-26 Product Selection. . . ...... ... V2-T1-27 Dimensions .............................. V2-T1-29 Heavy -Duty ................................. V2-T1-30 Heavy -Duty Double Door Safety Switch ....... V2-T1-39 Six -Pole Switches, ..... ...... V241-43 Double -Throw Switches .......... ....... .... V2-T1-46 EnviroLine Stainless Steel Switch . .. ....... V2-T1-53 Window Switches_ . ... ...... ...... V2-T1-57 Receptacle Switches. . _ . . . . . . ... ......... V2-T1-60 Non -Metallic KRYDON Switch ................... V241-62 Shunt Trip Safety Switch ... , . ....... V2-T1-65 NEMA 7/9—Hazardous Location Disconnect Switch V2-T1-68 Quick -Connect Switches ... ...... ....... V241-70 Solar Disconnect Switch ... ....... .......... V2-T1-75 Mill -Duty Rated, Heavy -Duty Safety Switch .... ... V2-T1-77 Heavy -Duty Fusible Safety Switches Accepting CUBEFuses .................. Elevator Control Switch . . . . . . .... Auxiliary Power Heavy -Duty Safety S Left -Handed Safety Switch ..... Heavy -Duty Surge Switch . ........ OEM Line Isolation (OL0 Switch .... Pringle Bolted Pressure Switch, .. , Type DS, Fusible and Non -Fusible Type Visi-Flex DE -ION . . , . ..... Flange Mounted —Variable Depth Flange Mounted —Fixed Depth ... Features, Benefits and Functions General -Duty (Cartridge Fuse) • Ample wire bending space provides for easier installation • Visible double -break quick - make, quick -break rotary blade mechanism • Side opening door on all enclosures • Mechanically interlocked cover to prevent easy access when the switch is in the ON position • With Class R fuses, switches may be used on systems capable of delivering 100,000A rms symmetrical ......... V2-T1-79 V2411-82 witch .... V241-85 V241-89 V241-90 V241-92 V241-95 V241-98 V2411-101 V2-Tl-105 ...... V2-TI-1" S7'_" • Clearly visirs46-arl, TA accessible retiar%, ' , where applica'-,N • Visible ON/OFF intkd�t L • Tangential knockouts on 30-60A designs • Ample wiring space • Double padlocking capability on 30-100A • Triple padlocking capability on 200-600A • Additional door locking capability • Bilingual English/Spanish door label on 30-100A • Tri-lingual nameplates 'ONTACT US: 6753 KINGSPOtNTE PARKWAY SUITE 111, ORLANDO FL, 32819 USA TEL, +1407-30&0099 enginewing&ndmarhom,com U 11. IS 7� 1.1- TC �JM DL5088 9.27,2023 MA M._ALVAREZ N.T.S. DATASHEETS LABELS W F.iT*N Pf3we'Ifig 1305ifM�5 IM0,414W111E General Duty Cartridge Fuse Safety Switch UPC: 782113213507 it #nsion s: * Height-. 25,23 IN, * Length- 10 IN - it, 15_5�2 IN Notes: Maximum hp rallngs apply onlywher, d al element fuses are used- 3Phase hp rating sho-Nn is a grounded B phasra- rating, UL lirstr_�d_ Spec ifications s - Typw.--, Geneeraf Du#,yXart6dge Fute - Ampef age Rating. 2(CA - Enclusure: NEMA 3R . Eactosurre Matpm-ial: Parinle-d galvanized stee-1 - Pu-s-a Class Provisiryn.- Class H fiusp_-, - Fusf-- Conflouration- gibe wits nsutraf - Numbeir Of Poles, Twro-polee . Number Of Wires: Thr-p—e-ware * ProdLict Category: Geaneral Duty Safetj SvMch * Voltage Rating: 249V Supp,o�n,ing documents; * Eatons Gartifif-atians: - UL Listed Prriduct cmpliagme. No Data Z-3, 201G Eaton, All 69-hts researe d, prt,-v:jnv,­n ,,;,-jrn Cartridge Fuse General -Duty Safety Switch Product Description • 30-600A • Suitable for service entrance applications unless otherwise noted • Fusible and non -fusible switches are 100% load break and 100% load make rated • The continuous load current of fusible switches is not to exceed 80% of the rating of fuses employed in other than motor circuits. Non -fusible switches are 100% fully rated • 200-600A features K-Series design • Horsepower rated • Fusible and non -fusible switches. Single -pole S/N through four -wire; 120/240, and 240 Vac • With Class R fuses, switches may be used on systems capable of delivering 100,000A rms symmetrical Note: Plug fuse switches are not service entrance rated. • Bolt -on hub provision. Provided for general -duty switches in a NEMA 3R enclosure. See Page V241- 14 for selection Application Description For residential and commercial applications. Suitable for light -duty motor circuits and service entrance. Switching Devices isms%= Product Overview ........................... General Duty. . . . . . . . . . . : ....... Standards and Certifications Product Selection, . . . . . ..... ....... ...... Dimensions ........ ........... ...... Heavy -Duty ...................... Heavy -Duty Double Door Safety Switch Six -Pole Switches ................. Double -Throw Switches ...................... EnviroLine Stainless Steel Switch, Window Switches ............ Receptacle Switches . . . . . . . . . ........... Non -Metallic KRYDON Switch, . ...... Shunt Trip Safety Switch ...................... NEMA 7/9—Hazardous Location Disconnect Switch Quick -Connect Switches, . ........ Solar Disconnect Switch , , .......... Mill -Duty Rated, Heavy -Duty Safety Switch . ... Heavy -Duty Fusible Safety Switches Accepting CONTACT US: 6753 r(INGSPOINTE PARKWAY SUITE Ili, ORLANDO FL, 32819 USA TEL. +1 407-3WOOM =7 CUBEFuses ................................ V2-T1-79 N W Elevator Control Switch, . , ­ .......... * ....... V241-82 0 00 N Auxiliary Power Heavy -Duty Safety Switch ... V241-85 Left -Handed Safety Switch V2-T1-89 Heavy -Duty Surge Switch V241-90 OEM Line Isolation (OLI) Switch, ..... V241-92 Pringle Boiled Pressure Switch ............. V241-95 Type DS, Fusible and Non -Fusible ....... V241-98 Type Visi-Flex DE -ION ....... V2-T1-101 Flange Mounted —Variable Depth ..... V241-%`IIP5� X-1- Flange Mounted —Fixed Depth .............. , 1 VZT Features, Benefits and Functions General -Duty (Cartridge Fusel • Ample wire bending space provides for easier installation • Visible double -break quick - make, quick -break rotary blade mechanism • Side opening door on all enclosures • Mechanically interlocked cover to prevent easy access when the switch is in the ON position • With Class R fuses, switches may be used on systems capable of delivering 100,000A rms symmetrical n 0 ­��TX ­T �1� �T­V e A 1 • Clearly visibleand x- accessible nedti* where applicable',, • Visible ON/OFF indic6t • Tangential knockouts on C b 30-60A designs • Ample wiring space DL5088 • Double padlocking 9.27.2023 capability on 30-100A • Triple padlocking capability MA on 200-600A M-ALVAREZ • Additional door locking capability a N.T.S. • Bilingual English/Spanish door label on 30-100A UATASHEETS & • Tri-lingual nameplates j LABELS MN Eell n ph',.a­.,-S- s62x If`% al, 8 To ;earn more about Enphase offerings, visit enphase,co m The high-powered smart grid -ready Dronrn,s, _ ril", 'A dramatically simplifies the , 3 -, , i installation process while achieving the highest system efficiency for systems with 60-cell and 72-cell modules, Part of the Enphase IQ System, the IQ 7A Micro integrates with the Enphase IQ Envoy', Enphase IQ Battery", and the Enphase Enlighten"' monitoring and analysis software. The IQ Series Microinverters extend the reliability standards set forth by previous generations and undergo over a million hours of power -on testing, enabling Enphase to provide an industry -leading warranty of up to 25 years. High Power Peak icutpu, power 366 VA Z 240 VAC and 295 VA,u 208 VAC Easy to install Lightweight and sirnple Faster installation with imip, oved, lights, two-whre cabflng BuOt-irt rapid shutdown, compliant (NEC 2014, 2017 & 2020) Efficient and Reliable Optimized for high powered 60 -cell and 72-cr?11 modules Highest CEC efficiency of 97s, More than a millron hours of testing Class 11 double insulated enclosuc UL listed Smart Grid Ready Compiles with advanced grid support, voltage and frequency ride_ through requirernenls Envoy and internet connection required Conifigurable for varying grid profiles Meets CA Rule 21 (UL 1, 741 -SA) ;-JENPHASE v1_1011 Enphase IQ 7A Microinverter INPUT (DC) lQ7A-72-2-US 6 , r1nmonly - a , se I d I module I pa i I r - i I nas - 295 W I - 1 4 11 60 - W 11 + Module compatibility 60 elf, 66-cell and 72-cell PV rnodules Maximum input DC voltage 58 A loovver point tracking voltage range2 18V_58V Min/Max start voltage 33 A 153 A Max DC short 6rcuit cul-ent (rnndue lsr'-1 15A Overvoltage class DC port DC part barkleed current 0 A PV array conliguratirm 1 x I ungrounded array; No additional DC side protection required; AC side protection requires ntax 20A per branch circuit OUTPUT (AC) @ 240 VAC @ 208 VAC V_A --- - ----- . .. .... Maxij'ouco continuous outputisciaer 349 VA 290 VA NornirW (L-L),voltage/ra hige4 240 A 1211-264 A 208 A / 183-229 A Maximuln-i continuous output current 1.45 A (240 VAC) 1.39 A (208 VAC) Nominal frequency 60 Hz Extended frequency iange 47 68 Hz AC short circuit fault current over 3 cycles 5.8 Arms Maxi urn units per 20 A (L I,) branch circuit" 11 (240 VAQ 11 `208 VAC) Ova,voltage ctass AC port IN AC port backfeed current 1,8 rn A Pow., ranter setting i_0 Po,ver factor (adJustable) 0,85 leading _ 0.85 lagging EFFICIENCY @240 VAC @208VAG CEC weighted efficiency 9TO is, 96,5% MECHANICAL ,G­die­n't temperatura range -400C toi 60cC Reialive hurnmitv tense 4% to 1001/-, (condensing) Conoeetolr type: DC (IC7A-72-2-US) MC4 Dirronsions (HxWxD) 212 rum x1 7F mm x 30.2 mrn, (,,viithout bracket) Weight 1,08 kg (2-38 Ibs) Cooling Natural convection, -- No fans U& 6753 KINGSPONTE PARKWAY SUITE 111, ORLANDO FL, 32819 USA TEL: +1407-308-0099 Approved for wet locations Yes Pollution deg=,ee PD3 g'7 Enclosure Class If double-irisutated, corrosion resistant polymeric enclosure Environinentai category UV exposure rating NEMA Type 6 11 outdoor FEATURES T_ El xT ciminunication Power Line Communication (PLC) Monitwtng Enlighten Manaapr and MyEnkghten morlooring Options Compatible viith Enphase Q Envoy Disconnecting means The AC and Do connectors have twen evaluated and approved by UL for use as ttei- -b,rsfi_T�%,TJ� rc, F disconnect required by NEC 690. Av, Compliance CA Rule 21 (UL 1741 -SA) UL 62109-1, UL.174!/IEEE1547, FCC Parr 15 Class B, ICES-0003 Ciass B, ZI CANSA C22.2 NO1071,01 T � iris productis UL Listed as PV Rapid Shut Down EquirrTlent and confowns mth NEC 2014, N 2017, and NEC 2020, sects 690.12 and C212.1-201 5 Rule 64 218 Rapid Shutdown of PV Systerns, for AiCand DC conductors, when installed accordinq manufacTurer's instructions. //g 9.27.2023 1 No -f-forcen DC/Ail ratio. See the cwrlpati_b�;�­iy calculator 3t cornpoibihty. 2, CEC peak oomr trackinqpor�arie ran is 38 V V, MA 3, MaximufT, uonfinu ��l.is inpiji, ouf�er-, is In 2A A, voltage r",inge. can be extcrid,�d beyond nominal if reclu'red by the ut, ay� M,ALVAREZ D, DffMs inay vwy, HofLr €o iocaf requircrncnGs to define the number of, Pcf branich y0ur area, ­E N.T.S. To learn more about Erlphase offerings, visit enphase.com lr GATASHEETS 'V! C I j,: LABELS ENPHASE �4 IBM I �GONTACT US: 0 Combiner p 6753KINGSPOINTE PARKWAY SUITE ri1, ORLANDO FL, 32819 USA ODEL NUMBER , , _, TEL. +1407-3SO09 iz,Y ,tr'ya i r.,,n`s=;:err; 4"VA jd a,z €%Frsds.S,Ak"i4;,.�.,i �,�zfg ,.� .i�@sy #.$r„. ,#�.,,..v .P. s ,<"'..^s, ya,w�.,'R,3a.,r{„f «` sOg(t +;: .i,. �. ,d'..`=� N x T � T � x � '� The PA C no _ r a � � r eng�e�a�aCrAaindinarhome.can to _.,.r .,,. s ,... �., _ ,,.,.. �._�e. rss, M, 4 _.,gs„x, W wd 0 a,Y o V. ..¢_> 7 wJp}_-.,,?,s, .} 3s_ `�._ 2 _J.it ,x 2 coy vath Combper 4V ti;C g s. s v, _ E_, e a t �# P F. % f P d ➢ a + L,f"r' s N s ,:r s. , Kt! .rf °� ACCESSORIES AN EPt-ACEMEN PARTS E*_.} _ . < ._f;lrs by .. for E n A Mrs up._ r1! w..."`E. 1 tea. an � Cc a D Z X 405 14 RT A EL&K, R"Mm td_ ;�' �,A'L,.� 0.;T �.� s,�>..°r._ �r rr�sv. a'�f�a? }��-T<..r ,�r�.f_.x,.�t_._.,��3; Rwwv�L rd(aua (f3 „�,,, ,r .r 'e"6 " tl?3u. E.i u5.'>•wv Y`'��.,f8.d �M i c. eSi�fiiJ�~n'-f 4': � � a•• 4 �a zee a Psi n aes2 „_ r r0YY s F c h ,,� EBa �� n + x_ N f .�-. s �er�T.� �`v � sae i �-I 3-�; s fir} �.:< 6& Aa a E r ,.�r owl WI .. < ,_r� _O,, —� gy- MA h { =.Mac y s ffi a s �= a tea_ ��,.r,g,..e.� >a ffi rr`, ,a Simple ,"wEr'z*wi,..ak;a,-. xv f,.% � x..,z,g F },i fl £ se5 E I < Y 5C� i ,..�.,�-ma�g..h„ar,.-.s t�~3 a:rs^i.�Ct ..%:g,..,r,�;.s}�_,,. MECHANICAL..,�}�.;�"� u 4� ANOWS„;r it=n,. i£ �.2,.�t ,tr �»,.:� r ,,.,�......�s,. m n 0.19t 6 <4 } nr x a 6 fi ci5cutn z n, q 3ai , ,,. , .. �' g i c VIL 2MY HAMMW 3 r x %m d .._ rainy s.v;Q T wyr+ b o r v4sombwse c-mG.rc ;£,cov, � �� E�sE<t IN ERN T C t° _ 0 P T'tG S DL-5088 9 27 2{323 M ALVAREZ 174, -SA} T.u. T t A sa,. C (tt ipl Y, %1 4C ENPHASE, kTo ; aTr vis,,rt Ems€ rafaStBBTs 1A6615 Kyo..ta F,ev , _ Coy A &AWZA M 2 N, 6 VM, I� US: A B SIDES MAY BE ENERGIZED IN THE OPEN POSITION NEC 690.13(B) / Roll: 596-OOS78 10-Pk: 596-00893 / Metal 5-Pk: 596-00921 SOLARR INFORMATION WINDMAR SOLAR a, 9 ♦6753 Kingspointe Odando, FL 32819 NFPA 1 2015 SECTION 11.12.2.1.5 LABEL FOR: INSTALLER INFORMATION LABEL SIZE: S' x 2" PRODUCTION/ NET METER (BI-DIRECTIONAL) NEC 705.12(D)(3) & NEC 690.59 / Rdi: 596-00495 10-Pk: 596-09665 / Metal SPk: 596-00833 • DISCONNECT, POINTS OF CONNECTION "M _�Q ELECTRICAL3±Q9K-HAZAM TERMINALS ON THE LINE LOAD SIDES MAY BE ENERGIZED IN THE OPEN POSITION NEC 690.13(B) / Rcdl: 596-00878 1 O-Pk: 596-00893 / Metal 5-Pk: 596-00921 own mm I MEW Engravable 5-Pk: 596-00862 NEC 690.54 / RaII: 596-OWS2 / 10-Pk: 596-00882 w+ornaaLwcac r.,,. Engravable 5-Pk:. NEC 705,10 & NEC %0,56(8) Roll: 558-00350 LABEL FOR RAPID SHUTDOWN NEG690.56(C)(IXa) " NEC 690.13(B) 1 Roll: 5MOO243 / 1O-Pk: 596-00675 / Metal 5-Pk: 59"0860 AWARNING THE DISCONNECTION OF THE GROUNDED CONDUCTOR(S) MAY RESULT IN OVERVOLTAGE ON THE EQUIPMENT NEC 690.31(1) t Rdl: 596-09323 10-Pk: 596-093241 Metal 5-Pk: 5WO0924 NEC 690.54 / Roll: 596-00892 / 10-P 596-00882 .rrvawc�ro«,'. Engravable 5-Pk: 596-00923 EMT, CONDUIT RACEWAYS "(REFLECTIVE MATERIAL REQUIRED) NEC 690.31(G)(3)(4) / Rdi 596-W205 / 10-Pk 598-00678 4 s v < NEC 690.31(GXI) / Rolt 596-00257 NFPA -1 11.12.2A,3.1 AND FFPC 11-12.2.1.3.1 THE LABELS OR MARKINGS SHALL BE VISIBLEAFTER INSTALLATION. THE LABELS SHALL BE REFLECTIVE AND SHALL HAVE ALL LETTERS CAPITALIZED WITH A MINIMUM HEIGHT OF 318 IN (9.5 MM) WHITE ON RED BACKGROUND. PV POWER CIRCUIT LABELS SHALL APPEAR ON EVERY SECTION OF THE WIRING SYSTEM THAT IS SEPARATED BY ENCLOSURES, WALLS, PARTITIONS, CEILINGS, OR FLOORS. SPACING BETWEEN LABELS OR MARKINGS, OR BETWEEN A LABEL AND A MARKING SHALL NOT BE MORE THAN 10 FT (3M). LABELS REQUIRED BY THIS SECTION SHALL BE SUITABLE FOR THE ENVIRONMENT WHERE THEY ARE INSTALLED. f s♦ SHUTDOWN SM+ITCH TO THE "OFF" POSITION TO SHUT DOWN ENTIRE PV SYSTEM I A& -sear asaramaw. FFPC 2020 AND NFPA 1.11.12.2A.1.1 NEC 690.54 / Rdi 596-00892 / 10-Pk: 5VIO0882 aaa7ovo+.ruc ac ogca�ar.r""" erw� .vim„- i i Engravable 5-Pk: 596-00923 NEC 705.12 (B)(2)(3)(b) LABEL 04-316 FOR RAPID SHUTDOWN NEC 710.15(C) & 692.9 (C) / ROII: 596.00591 10-Pk: 5WO0699 / Metal 5-Pk: 596-00837 NEC 690,15 (C) & NEC 690.33(E)(2) Roll: 596-00244110.Pk: 596-00671 NEC 690,13 (F), NEC 705.12(B)(3.4) & NEC 690.59 Roll: 596-00587 / 10-Pk: 596-00666 Metal 5-Pk: 596-00834 NEC 705.12(BX3-4) & NEC 690.59 / Rom: 596.00495 10-Pk: 596.00665 / Metal 5-Pk: 596.00833 NEC 705.12 (13)(2)(5) / Roll: 596-00883 10-Pk: 596-008841 Metal 5-Pk: 596-00917 6753 KINGSPOINTE PARKWAY SUITE 111, ORLANDO FL, 32819 USA TEL: +1407-3WL'099 NEC 690.13(8) / Roll: 596-00243 IC -Pk: 59"06751 Metal 5-Pk: 59Cr00860 DATASHEETS LABELS m CONTACT US 6753 KINGSPOINTE PARKWAY SUITE I 11, ORLANDO FL, 32819 USA TEL, +1407-308-0039 engmeering@wndmarhomemm ck S: _F M (D ry "T M 06 C) v) ------- cy) w LOCATION MAP AERIAL VIEW PLAN VIEW 0 LL tab COORDINATES: LAT28.277225', LON -82A80274° COORDINATES: 28'16'38.0"N 82'10'49ff'W LL < F__< _j_j w T_ GC 3: T_ o CL N MW 0c) INDEX PERMITTING PLANNING NOTES u C-1 COVER SCOPE 'OF WORK: Il I IT E-1 ELECTRICAL DIAGRAM & CALCULATIONS INSTALLATION OF GRID -TIED PHOTOVOLTAIC SYSTEM 0% P_ E S-1-1.1 SYSTEM LAYOUT A., 7_71T'. 71, X 4D I- S-2 SYSTEM LOCATION MAP SYSTEM DESCRIPTION S-3-6 STRUCTURAL DIAGRAMS & CALCULATIONS GRID -TIED PHOTOVOLTAIC SYSTEM: STA'11'E OF D-1-6 DATASHEETS & LABELS A, (20 ) ENPHASE IQ7A-72-2-US MICRO -INVERTERS) 349W 4z�-. 4 () (20 ) HANWHA Q-CELLS Q.PEAK DUO BLK-GlO+ 400 o", .... R ..._ SYSTEM: REVISIONS (20 ) PHOTOVOLTAIC MODULES ARE CONNECTED INTO (20) MICRO -INVERTERS (20 ) MICRO -INVERTERS CONNECT IN TO (2) CIRCUITS OF (10, 10) MICRO -INVERTERS WHICH FEED 2-P 240V 20A CIRCUIT BREAKERS NUMBER DATE DESCRIPTION A\ 12/07/23 CHANGED CT LOCATION TO AS BUILT AND CHANGED OCPD FEEDER CONDUCTORS FROM TOTAL PHOTOVOLTAIC SYSTEM STC RATED ENERGY POWER PRODUCTION OF 8,000 DC WATTS 6,980 AC WATTS 12.7.2023 BRANCH BREAKER TO BAR- AS BUILT. F1111- ­11 INVERTER HAS MAXIMUM POWER POINT TRACKING (MPPT) 01/24/24 CHANGED COMBINER BOX BREAKERS FROM 4 BREAKERS TO 2 BREAKERS. INVERTER(S) CONFORMS WITH NEC 2020 SECTION 690.12 & C22.1-2015 RULE 64-218 RAPID SHUTDOWN OF PV SYSTEMS. INVERTER(S) CERTIFIED IEEE 1547 & CERTIFIED UL1741 MA M.ALVAREZ ALL ELECTRICAL EQUIPMENT INSTALLED ARE UL LISTED N T.S_ FLORIDA CODE SUMMARY COVER FIRE BUILDING ELECTRICAL FL FIRE PREVENTION CODE 7TH EDITION, FBC 2020, 7TH & IBC 2018 NEC 2017 & NFPA 70 ®1 NFPA-1 (2018) & NFPA-101 (2018) ASCE 7-16 NOTE: IN THE EVENT OF CONFLICTING REGULATIONS THE MOST RESTRICTIVE SHALL PREVAIL. PV MODULE RATINGS ITEM DESCRIPTION: CONTACT US: MODULE MAKE HANWHA O-CELLS 5753 KINGSPOINTE MODULE MODEL, 0 PEAK- 400 1 PV MODULES. TYPE: HANWHA Q-CELLS Q.PEAK DUO BLK-G 10, 400 PARKWAY SUITE 111 MAX POWER 400 W 2 MICROINVERTER: ENPHASE IQ7A-72-2-US (EQUIPPED WITH RAPID SHUTDOWN). ORLANDO FL, 32819 USA OPEN CIRCUIT VOLTAGE 45.30 V MAX POWER POINT VOLTAGE 37,13 V 3 ENPHASE 0 CABLE MALE CONNECTOR (Q- 12-10-240) 12 AWG DOUBLE I INSULATED THHNITHWN-2. TEL: +1 407-308-0099 SHORT CIRCUI r CURRENT 1-lAa A 4 1 ENPHASE RAW Q-CABLE (0-12-RAW-300) PER BRANCH AND 1#6 BARE COPPER FOR MAX POWER POINT CURRENT 10,77 A GROUND IN 1" CONDUIT. ITEM MANUFACTURER MODEL LISTING COMPLIANCE 5 JUNCTION BOX 6" x 6' SUITABLE FOR WET LOCATIONS (UL ENVIRONMENTAL RATING TYPE 4X). k Pr/ MODULE QI 400W UL 6 2910 THHN PER BRANCH AND 1#6 THHN FOR GROUND IN V CONDUIT TO CARRY BRANCH A INVERTER ENPHASE LOCI. UL CIRCUIT CONDUCTORS TO LOAD CENTER. NOTE: INSTALL OUTDOORS PVC EXPANSION FITTING WHERE NEEDED. ALL DISCONNECTS ENPHASE DO & AD Ur B1 B2 B3 B4 135 B6 B7 B8 B9 B10 ALL OVERCURRENH ENPHASE DO A AC UL PROTECTION 7 ENPHASE to COMBINER BOX 4C WITH 10 ENVOY METER CK24CEANI 125A BUS RATING 120/240 VAC WITH 2 BREAKERS 20A/2-P & I BREAKER (15A OR I OTH/2-P FOR IQ ENVOY FSEC CERTIFICATION Q-CELL 4SoW INSTALLED BY MANUFACTURER, NLN, NUMBER ENTRASE IQHCA R%A­I6JHFAA 2 3 NOTE: IQ ENVOY METER ENABLES WEB -BASED MONITORING AND CONTROL, AND PROVIDES PRODUCTION METERING AND OPTIONAL CONSUMPTION MONITORING. THIS METER IS INCLUDED IN THE LIST OF ELIGIBLE METERS FROM THE CALIFORNIA ENERGY COMMISSION, 4 8 396 THHN CU AND 1#6 THHN CU FOR GROUND IN 1" CONDUIT, i07A e 9 BOA FUSED DISCONNECT FOR PHOTOVOLTAIC AC DISCONNECT/RAPID SHUTDOWN DISCONNECT 5 Al A2 A3 A4 A5 A6 A7 A8 i A9 A10 SERVICE ENTRANCE RATED WITH 40A FUSES 20 x 1.45A x I .25 = 36.25A = 40A (OCLYD) NOTE: DO NOT INSTALL NEUTRAL -TO -CASE BONDING GREEN SCREW, THIS PREVENTS CD OBJECTIONABLE CURRENT AS PER NEC 250.6 � "zi- I TOTAL PHOTOVOLTAIC SYSTEM SJC RATED DC POWER PRODUCTION OF 8000 W 06 Er) 2 INVERT ER HAS MAXIMUM PONDER POINT TRACKING (APPT), ROOF LEVEL 10 EXISTING UTILITY METER. M 3 INVERTER MEETS REQUIRFIOENTS OF 3-P POWER. LU cy-) 4 AVERTED MEETS IEEE 1547, 5 INVERTER MEETS UL1741 6 ALL ELECTRICAL EQUIPMENT INSTALLED ARE UL LISTED. 11 EXISTING RESIDENCE 150A MAIN BREAKER. 7 FED ADMINISTRATION CODES NOW IN EFFECT NEC 2017 FBC 2020' E-1 FRO < 0 LL N ADMINISTRATION' ALL ELECTRONICS SOLAR PANELS AND ASSOCIATED ELECTRICAL 6 9 15 12 LOAD SIDE TAP INTERCONNECTION PER NEC 705.12(B)(2)(1)(b) N EQUIPMENTIO BE INSTALLED ARE UL'USTED.' 16 LL U) U) SYSTEM AUTOMATIC OPERATION 13 EXISTING MAIN SERVICE PANEL WITH 200A BUSBAR RATING. U_ _j I GRID POWER IS FRIESEN FTHOOTGVOLTA[� SYST M FEEDS THE LOAD AT DAY TIME NOTE: PROTECTION OF MSP BUS BAR PER NEC705,112(8)(2)(3)(b) - 1201 RULE. (200A BUS RATING 1.2 _j PLO V )L AID S F 12 U) < 2 GRID POWER IS LOST, STEM, AUTOMATICALLY DISCONNECTS FROM 150A MAIN BREAKER = 90A AVAILABLE FOR SOLAR Lu THE GRID, 15A 3, PHOTOVOLTAIC SYSTEM WILL AUTOMATICALLY RESUME FEEDING POWER TO THE GRID. WHEN THE PROPER GRID VOLTAGE AND FREQUENCY IS RESTORED (IEEE 7 _j STANDARDS) AND I HERE IS ENOUGH SUNLIGHT, i OV, 10 14 EXISTING GROUNDING ELECTRODE CONDUCTOR. VOA SCHEDULES 40A- 15 EXISTING INTERIOR DISTRIBUTION SUBPANEL WITH 225A BUSBAR RATING. r 0 SCALE HILLS PRODUCTION I 50A 16 200A FUSED DISCONNECT WITH 160A FUSES NEMA SIR FOR INTERIOR DISTRIBUTION SUBPANEL. LLJ 15OA- THIS IS REQUIRED TO COMPLY PER NEC 240.21 DUE TO THE DISTANCE BETWEEN MSP AND DO N CT 40A IP YAL1P ­0 IN 13 INTERIOR DISTRIBUTION SUBPANEL EXCEDG 25 FEET OF CONDUIT AND TO COMPLY WITH 705.12 OVERLO(BM2 �1 . Ilb, TO PROTECT SUBPANEL AND FEEDER CONDUCTORS FROM POTENTIAL 17 3#3/0 THHN CU AND 1#6 THHN CU FOR GROUND IN 2' CONDUIT. 2 8 17 No -ISIDDLIA; .1311 8 0 19 rig EXISTING FEEDERS CONDUCTORS X 1AING 1AINVEINICE I N ­DF 1—UL, T01 W1 -ININS-Irs "I II-11 l ra E, 1A ro""'IND 7 A o 19 NEW ENPHASE ENVOY CONSUMPTION CURRENT TRANSFORMERS. NOTE: BOTH THE FEED -THROUGH CONDUCTORS AND THE CONDUCTORS OF ALL EXISTING LOAD .11, A-1 TAPG PUNTARSPEWINII1111,61YUCAPPE TY 'a _ ' —1-111-HIII ,q,��",NLMIERNEC21042�EIAND301I )�7 1-1—ell 1111 BREAKERS IN THIS PANEL MUST PASS THROUGH THE CONSUMPTION CTs TO MONITOR THE CONSUMPTION OF ALL LOADS rc-1-1 STII 1111 ..11 11F �Anrrllrl zIN"A" 11,,Au_ 1111 INSIDE RESIDENCE 14 _11clo— Y�r_c RI "'CLIT NX171—F-Al .,A Do !"Darat ­11 GROUND LEVEL NOTES: _irra_� 111AY 11 — F 'VE V, eFDE PcA P'FIDI pAr 11 MDP��AT I 'GIARII TI11 1111IIH iN Ar" T1IAc 1111N ­1 ,c _­` N ALL CONDUITS AND RACEWAYS APPROVED PER METHOD NEC 2017 AND FBC 2020. NEN Sli ANC—ENI -A "F 11 111111111111, r1re IN THE EVENT OF CONFLICTING REGULATIONS THE MOST RESTRICTIVE SHALL Al IR , G, ­­ ' '11IT1111111 11' Cip""HAAAN-11) no E RA AINIAE-er, AND SIOUNHI'C� LLiTiY0`U`&JCF1,R M, L—IDA—i-N TIASS 'Ne THIS ANDI I AVE NcV11TIAAA1 EAN-iiDNIIAIGI-IT VC-EXASAOICT- ­EI PREVAIL, ALL EQUIPMENT IS SUITABLE FOR OUTDOORS INS FAILLATION AND RATED FO 90'rl. VDV)"� NIT'N THE SIZE OF ALL CONDUCTORS BASED ON THEIR AMPACITY FOR AN A BIEV : s % A, TEMPERATURE OF 194-F (90-C) WAS TAKEN FROM NEC TABLE B.310,15(B)(2){} Y "`�A ON' 4 C­ IQ. SYSTEM DATA 1a6. IN" Voltage Drop Calculation Temperature Correction TOTAL W: 8.000 WATTS DC / 6,980 WATTS AC MSP BUSBAR RATING: 200A , 0'. STATE OF TOTAL PV MODULES: 20 PHOTOVOLTAIC MODULES Nr ort z. Formula: NEC 2017 -TABLE 310.15(B)(A) . 4 PV MODEL: HANWHA O-CELLS Q.PEAK DUO ELLK-G10F 400 0 Formula: INVERTER: ENPHASE IQ7A-72-2-US MICROINVERTER (2*L*Imax*k) ttN "OAL,! VD = [max BATTERY: NONE ttlifliffWi D Temperature Rating SYSTEM RISER WIRING DIAGRAM EQUIPMENT LOCATION RACK SYSTEM: UNIRAC SCALE NIS Ambient Temperature Correction Factors BECAUSE THE SERVICE NEUTRAL CONDUCTOR PROVIDES THE EFFECTIVE GROUND -FAULT CURRENT PATH TO THE POWER SUPPLY f250.24(CC. YOU COST I AVE TO INSTALL AN - L = Length of wire Ambient Temperature: 31-35 (� C) NOTE: ENGINEER CERTIFIES THAT THIS PLAN COMPLIES WITH 107.3.5 FBC. EQUIPMENT GROUNDING CONDUCTOR WITHIN PVC CONDUIT CONTAINING SERVICF-ENTRANCE CONDUCTORS [250 142FDT) AND 352.60 EX 21. - k = Wire material 1. THREADED FITTINGS, TERMINATE METAL RACEWAYS 70 METAL ENCLOSURES BY THREADED HUBS ON ENCLOSURES (IF MADE WRENCH TIGHT). DL5088 2. THREADLESS FITTINGS. TERMINATE METAL RACEWAYS TO METAL ENCLOSURES BY THREADLESS Fill UNGS (IF MADE rIGH-0. - Imax = Current ArnbinetTempe-to-87-95 F IMPORTANT NOTE: NEC 70512 3, OTHER LISTED DEMDES SHEAF INCLUDE BONDING -TYPE LOCKNUTS, BUSHINGS WEDGES. OR BRUSHINGS WITH BONDING JUMPERS, WHERE TWO SOURCES ONE A UTLiT Y AND THE OTHER AN INVERTER. ARE LOCATED AT OPPOSITE ENDS OF A BUSBAR FLAT CONTAINS LOADS, THE SUM, OF 125% OF 12,72023 THE INLV`Ll�71UNS) OUTPUT CIRCUIT CURRENT AND [HE RATING OF THE OVEIGUARRENT DEVICE PROTECTING THE BUSBAR SHALL NOT EXCEED 120% THE AMPACITY DESIGN TEMPERATURE 109'F HISTORICAL RECORDED HIGH TEMPERATURE (FLORIDA) FOR CONDUIT INSTALLATION MORE THAN 6r7' ABOVE ROOF, DOES NOT REQUIRE - 2 = Constant OF THE B BEAR. THE BUSBAR SHALL BE SIZED FOR THE LOADS CONNECTED IN ACCORDANCE WITH ARTICLE 220 A PERMANENT WARNING LABEL SHALL BE APPLIED ADDITIONAL TEMPERATURE ADDED. ACCORDING TO NEC TABLE 310 15(B)(2)(r) FOR TEMPERATURE 105 10 113: USE TEMPERATURE CORRECTION FACTOR 87 MULTIPLE FACTOR OR IN ResultsI: TO HE 1)I S1 RIBUTION EQUIPMENT ADJACENT TO THE BACK -FED BREAKER FROM THE INVERTER THAT DISPLAYS THE FOLLOWING OR EQUIVALENT WORDING: TABLE 31015(BLIL #10 THAIN-2 RATED 40 AMP (NEC TABLE 310.15RF16) X,87 = 34,8 AMPS, FOR 8 CARRYING CONDUCTORS IN SINGLE CONDUIT ADJUST MENI" FACTOR GJIV�, (NEC MA - D = Conductor Properties RNING TABLE 31TIMB)CFa) 0,7 1 34,8A = 2426 AMPS IIIIIINE, 11 "1 TC =37,76A INVERTER OUTPUT CONNECTION; DO NOT RELOCATE THIS OVERCURRENT DEVICE. BONDING MIOCLAMP ASSEMBLY M.ALVAREZ THEWARNING SIGNIS} OR LABELS) SHALL COMPLY WITH 110 21(B) 1. STAINLESS STEAL MIDCLAMP POINTS, 2 PER MODULE, PIERCE MODULE FRAME ANODLZARONTO BOND MODULE TO MODULE THROUGH CLAMP Results: Conductors EXCEPTION DO UIPMENT WITH MULTIPLE AMPACITY BUSBARS ORC ENTER FED PANELBOARDS ARE NOT ADDRESSED BY THIS PROVISION. 2� SERRATED FLANGE NUT BONDS STAINLESS S TFF1 CLAMP TO STAINLESS STEEL I -BOLT S, NEC2017,- TaME210,35RI)(17) Allowable NEC (BIDS RATING] X 1,2 - (MAIN BREAKER) - 120% RULE VD 1.04 V Ampac ties of Single -insulated Conductors 3, SERRATED T­BOLT DEAD PEN ENTATES RAIL ANODIZAROM TO BOND T-BOLT NUT CLAMP. AND MODULES TO GROUNDED AM RAIL, Rated Up to and Including 2,000 Volts in Free THE NEC GIVES YOU THE CHOICE OF FOUR METHODS FOR ENSURING ELECTRICAL CONTINUITY AT SERVICE EQUIPMENT, SERVICE RACEAYC AND SERVICE CROSS SECTIONAL AREA CALCULATION: ELECTRICAL DIAGRAM & Air, Based on Ambient Temperature CONDUCTOR ENCLOSURES (250 92(B), CROSS SECTIONAL AREA OF ", THHN = 0,2028 SQ,IHCALCULATION 1 , BONDING JUMPERS BOND METAL PARTS TO THE SERVICE NEUTRAL CONDUCTOR THIS REQUIRES A MAIN BONDING JUMPER f250 24LBL AND 250.281. BECAUSE CROSS SECTIONAL AREA OF I'TUBE, OSTI SOLAR, FILL % Results: , Cable 46 AING THWIN 2 - Capacity 10S A DLE SERVICE NEUTRAL CONDUCTOR PROVIDES THE EFFECTIVE GROUND -FAULT CURREN I PATH TO THE POWER SUPPLY [250 24(C), YOU DONT HAVE TO 10 2028 / 0 79) S 100 = 2SEs'. < 40% order 90 C INS TALL AN EQUIPMENT GROUNDING CONDUCTOR VOTHIN PVC CONDUIT CONTAINING SERVICE -ENTRANCE CONDUCTORS G50142,A),"I.Ild 352,60 s. 21, A,— , C - Capacity 6 FITTINGS. TERMINATE METAL RACEVJAYS TO METAL ENCLOUSURES BY THREADED HUBS ON ENCLOUSURES OF MIADEVORENCHIGGHT) FILL per. NOTE: VD% OM % —MoT 1" PVC Sciedole 40 2 IFIREADEDLESS conduct.,, 3. FHREADEDLESS FITTINGS. TERMINATE METAL RACEWAYS TO METAL ENCINOUSURES By THREADLESS FITTINGS (IF MADE TIGHT). ALL FILL CALCULATIONS ON THIS DESIGN HAVE BEEN DONE IN COMPLIANCE WITH NEC312S, E-1 4, OTHER LISTED DEVICES THESE INCLUDE BONDING -TYPE LOCKOUTS, BUSHINGS, WEDGES, OR BUSHINGS WD H BONDING JUMPERS i SYSTEM OVERVIEW CONTACT US: SOLAR PANELS 20 x HANWHA 400W 8753 KINGSPOINTE -ARRAY) PARKWAY SUITE 111, INVERTERS: 7A - 2 RS:20 ORLANDO FL. 32819 USA (INVERT I IE (INVERTER EFFICIENCY: 95°/ ) 5%) TEL +1407-308-0099 MOUNTING TYPE: UNERAC engineenr@@mndmaftme.com EVALUATION OF DESIGN LOCATION: FLORIDA, USA RECORD LOW TEMPERATURE: 35.00 °F EW 200A FUSED DISCONNECT � AVERAGE HIGH TEMPERATURE: WITH 150A FUSES FOR INTERIOR 78.00 °F EXISTING METER ! MAI SUBPANEL SERVICE PANEL RECORD HIGH TEMPERATURE: EW 60A/40A FUSED AC PV 98.00'F DISCONNECT/RAPID SHUTDOWN NEW ENPHASE COMBINER BOX TECHNICAL DATA av PV PEAK POWER: 6,980 wp EXISTING INTERIOR NUMBER OF PV MODULES: 20 DISTRIBUTION SUBPANEL -- NUMBER OF INVERTERS: 20 (D MAX. DC POWER 40OW 06 n U-) MAX. AC POWER 349W Wco GRID VOLTAGE: 240V NOMINAL POWER RATIO: 95 % gy PV ARRAY Q LL U) NUMBER OF PV MODULES: < NUMBER OF INVERTERS: 20 —J PEAK POWER OUTPUT: 40OWp Lit T- MPP PV VOLTAGE 37.13V o( OC PV VOLTAGE 45.30V i- MIN. DC VOLTAGE (240V GRID) 33.OV CN o MAX, PV VOLTAGE 40V a ( W MAX. DC VOLTAGE (INVERTER) 58V INSTALL PVC EXPANSia Gy) N MAX. CURRENT OF PV 11.14A O MAX. DC CURRENT 10.77A FITTING IN OUTDOORS PVC CONDUIT STRAIGHT RUN PV & INVERTER COMPATIBILITY PV ARRAY & TYPE OF INVERTER ARE 0 COMPATIBLE - THE NOMINAL POWER RATIO (MAX. DC POWER OF THE INVERTER DIVIDED BY THE PEAK POWER) IS WITHIN THE RECOMMENDED RANGE (80% - 120%). w "a;`� d LEGENDCS T E Al ' 7` ® 36" FIRE CODE OFFSET (NFPA 1, 2015, Ch. 11) JUNCTION BOX FOR 9 ; r EXISTING UTILITY METER � WET LOCATIONS e E;-oM EXISTING MAIN SERVICE PANEL F NEW COMBINER BOX .444 [Kh NEW 6OA/40A FUSED AC PV DISCONNECT/ RAPID SHUTDOWN DISCONNECT %C C C C C %C C C S ATE OF NEW 20OA/150A FUSED PV 71 ��. c C �� '' R " SYSTEM AC DISCONNECT Ep . EXISTING INTERIOR DISTRIBUTION SUBPANEL 0 a JUNCTION BOX SUITABLE FOR WET LOCATIONS " ff C %c ffC %C %c p� C LA C CC C ® ® ROOF VENT LOCATIONS - RIDGE VENT LOCATIONS ROOF ACCESS POINT 13L5088 0 ROOF ACCESS POINT 12 7 2023 NIA ROOF INFORMATION ROOF TYPE: ASPHALT SHINGLE M. ALVAREZ TOTAL ROOF AREA: 3182.60 SQFT TOTAL PHOTOVOLTAIC AREA:422.40 SOFT ROOF AGE: <5 YEARS N.T.S. PRESSURE ZONE: 1 & 2 MEAN ROOF SLOPE: 4.6/12 TOTAL MODULES: 20 TOTAL ROOF MOUNTS: 42 SYSTEM LAYOUT TOTAL POINT OF CONNECTIONS PER MODULE: RACKING SYSTEM: UNIRAC ALUMINUM RAILS PER MODULE: 2 TILT 1:21 ° AZIMUTH 1:181 PHOTOVOLTAIC PANELS LAYOUT SfALE'. BITS �a� aa�� Nfvaiffi�� ROOF TYPE: ASPHALT SHINGLE TOTAL ROOF AREA: 3182.60 SOFT TOTAL PHOTOVOLTAIC AREA:422.40 SOFT ROOF AGE: <5 YEARS PRESSURE ZONE: I & 2 MEAN ROOF SLOPE: 4.6/12 TOTAL MODULES: 20 TOTAL ROOF MOUNTS: 42 TOTAL POINT OF CONNECTIONS PER MODULE: 4 RACKING SYSTEM: UNIRAC ALUMINUM RAILS PER MODULE: 2 TILT 1:21' AZIMUTH 1:181' CONTACT US 6753 KINGSPOINTE PARKWAY SUITE 111, ORLANDO FL, 32819 USA ,EL +1407-308-0099 CD Lf) m W co N 0 u- LL LL cf) U) < co o U) ry o co IL N MW cc) N o Dk DC C ACIkC 'kC DkC C�C D�C DkC DkC AFC3 s tr 7"A T 0,p DkC DkC DkC D 0 DkC ACC D ACC i Dkc DACC ACC [)kC R I r) Ir • DL5088 2® 4'MAX 12.72023 ARRAY#1 ARRAY#1 RAFTER FOOT (20) PV MODULES (42) ROOF MOUNTS nnA- SPAN SPACING M. ALVAREZ N-T-S- STRUCTURAL DIAGRAM 8' CALCULATIONS S-1.1 ARRAY WIND LOAD CALCULATIONS ASCE 7-16 VELOCITY PRESSURE 15'MEAN ROOF HEIGHT ZONE 1 317 PSF ZONE 2 - 56,6 FEE SOLAR PANELS 20 CONTACT US Z ZONE 3 = 56.6 FEE (NO MODULES) TOTAL. AREA (SOFT) 422,40 6753 KINGSPOINTE NOTE BASIC WIND SPEED (MPH) 170 30'MEAN ROOF HEIGHT ZONE 1 - 51.7 PSF ZONE 2 = 753 PSF PARKWAY SUITE 11 RAILS SPAN FOR UNIRAC STANDARD SM RAIL IS ALWAYS GOING TO BE ZONE 3 = 75,3 PSF (NO MODULES) _V - — - -1 1- - ORLANDO FL, 32819 USA BUILDING HEIGHT IF D 15-0" INSTALLED AT A MAXIMUM OF 4FT. OZ10 = 0.00256*KZ*KZT'KD'V'2 EXPOSURE CATEGORY C WHERE: TEL 1407-308-0099 ROOF PITCH 4,6/12 QZIG - ASCE 7-1 6 VELOCITY PRESSURE EVALUATED AT MEAN ROOF HEIGHT (PSF) 12` KZ =VELOCIFY PRESSURE EXPOSURE COEFFICIENT engineering@winignarhorneBrim KZT TOPOGRAPHIC FACTOR 'AR NO WIND DIRECTIONALITY FACTOR V BASIC WIND SPEED (MEN) FROM ASCE 7-16 MAPS REFERRED TO AS ULTIMATE WIND SPEED MAPS IN 2012 tBC, b", -No -Exposed: SPAN TABLE n CALCULATIONS FOR 15' MEAN ROOF 11 VELOCITY PRESSURE: QZIO - (100256`0,85*1 0*0 85'1-�5A 2 N/M^2 56.6 PSF SM I `__11'11 11711 11 IIINII " : ---------- ------------------ --------- -------------- ------­--------------------- ...... HEIGHT DESIGN WIND PRESSURE: P = OZIO'GCF - 56,6'0.85*0.70 = 33,7 PSF AS AN EXAMPLE, FOR AN ARRAY HAVING AN AREA OF 1,115 SOFT., THE TOTAL UPLIFTING (RESULTANT) FORCE Is 0 ACTING ON THE ARRAY WOULD BE 33Y PSF X 1,115 SQFT, z 37,575.5 LB. KNOWING THIS RESULTANT FORCE, THE 2" 4 -711 DESIGN ENGINEER CAN NOW DETERMINE THE NUMBER OF ATTACHMENT POINTS AND THE SIZE OF THE MOUNTING HARDWARE NECESSARY TO SAFELY CARRY THIS LOAD. 1-10 SM13 sMLT EMIT SMO $MIT 1 StAcT Sig sm, SM Star SWID SIATHD SMHO 8ils-4- c 155 SMLT SMLT SMLT SMLT SMLT 4- 1- Idg sM Is, I- - b 160 SMLT sMzT SMLT SMLT SMLT I Met $for SPA SM SINT SMRG SMI slated LIVE LOADS: X I' SS SERRATED T- BOLT I 165 SM, SMLT SMLT SMILT BUILT SM SM SM NA SMHD SRI SMHD SMOD LIVE LOADS ASSOCIATED WITH PHOTOVOLTAIC SYSTEMS ARE USUALLY ASSUMED TO BE DISTRIBUTED UNIFORMLY 70 EMIT SMLT SMLT SIVILT SMLT Sid SIX sta SIX SMHO SMHD ewe, SMHD 175 SMLT WILT SMLT SM SM SM SM Add IRA- Addead' Add Rai* Add Reif' AND ARE SMALL, ON THE ORDER OF 4 PSF OR LESS. HEX FLANGE NUT 150 SMLT SMLT sour SMLT sm sm sm sm SM Add sadd* Add Rad* Add Rott' Add Ra' i55 SMLT SMLT SMLT SMT sm sm W AddNav` AddRar Addfafg- Add Rah* AddsaP AddI ATTACHMENT INSTALLATION GUIDELINES AddA - Add it 160 SMLT N't' SMLT SMLT SM SM Add Bad -0 R-tD Add R-It` Add Pal' Addifte Adds 2 -'s, SMIX SMLT SMLT SMUT SM � j Addjfab� Addisea- Add Rail ":Add Raft* AddRatfs Add sed* Addftff* Addpain, 1. LOCATE ROOF RAFTERS AND SNAP CHALK LINES TO MARK THE INSTALLATION POINT FOR EACH 70 SMLT SMLT SUBT SMLT SPA �ftlt` Add P-e Add W' Add R"' Add Raff- Add Rails Add W' AddR.4- _1 Cfi 175 CvEf "ortz- soBT --sm Add fbitlAddAM Radb Add Rao- AddReg' Addlbig- AddRag- AddR.9' AsTiNanf- Addftg� ROOF ATTACHMENT. ry 2. DRILL A 7/32"PILOT HOLE AT EACH ROOF ATTACHMENT, FILL EACH PILOT HOLE WITH SEALANT.. 06 0 L0 150 SMLT NaLT $MET SPALT SM AddRaffe Add UP` Ad11 . .11- AddftA* AddRwl' AddloiP Addliall' Asitf Cl) )lr, x 3, ADD A "U-SHAPED" OF ROOF SEALANT TO THE UNDERSIDE OF THE FLASHING WITH THE LLI 155 EVUL SMUT SMUT sm SM Addival' Add fdg' Add Rall' AddR.1H Add WO AddfMI1- AddR.4- Add east' Cy') OPEN SIDE OF THE "U" POINTING DOWN THE ROOF SLOPE. Z Addlaol' Addloff- Addidaps Addfltfdf� AddRall 160 SMUT SMLT BMLT SM Add Rads AddR"* AddRed AM `bgr 165 SMUT WIT SM AM Adid[Rar AdduNrr` Add Rai Add Bain` Add RaP Addfftaf* Addiffeg' Add Ral' AddEbal. 4. SLIDE THE ALUMINUM FLASHING UNDERNEATH THE ROW OF SHINGLES DIRECTLY UP SLOPE FROM 0 LL_ 170 SWIL, sbAU am SIN Add Add Add Add Rel' :Add Add Rwl* Aid SBAP` Add Rai[* THE PILOT HOLE. N < ""'T, w� Add 5, ALIGN THE INDICATOR MARKS ON THE LOWER END OF THE FLASHING WITH THE CHALK LINE ON S" sm NA AddRaff` AddRail* Addia4s Ad~ A6dRa4- Addiodf- AddRaf- Addftr AddletO , "T, IR3 SMLT SMLT U� U. U) U) �, M_t> K, / THE ROOF TO CENTER THE RAISED HOLE IN THE FLASHING OVER THE PILOT HOLE IN THE ROOF. UNIRAC FLASHKiT PRO INSTALLATION DETAIL F LL Now Rxi spass, ird based an AsCE 7-IG, isapgrag Nsk Categoor If, RPOSLOPeUpto 26,57, adeansoofHeOtIf 15ft,5db,adCoefBceaRB­ 1.5,Proseresmidadeaddempe,00dules odP.RgL0 m. ob.Ov%dh d—b—f 67 ir, *,it 2 "its OR,— Of od,les u,minif pBrpodI to it, met b,da. ov,,hed to L feet m1uruld on me do-SIld, side 01 6. FASTEN L-FOOT AND FLASHING INTO PLACE BY PASSING THE LAG SCREW AND PRE -INSTALLED SCALE NIS < "it, me ,f 5rd.,Mrs,,1 Id cis'eq--ts o, the sa.,M_O'd0W,_ STAINLESS STEEL EPDM WASHER THROUGH THE L-FOOT EDPM GROMMET. AND THE RAISED HOLE LIJ IN THE FLASHING. INTO THE PILOT HOLE IN THE ROOF RAFTER. In potI Pvkhd,aaal) offoefties gbdf I. "ic.1 -of emas lembe, (ASIBI 7. DRIVE THE LAG SCREW DOWN UNTIL THE L-FOOT IS HELD FIRMLY IN PLACE. W` is jr < J, 'k J6 v a X & 0 ASCE 7-16 AS OF 2021 UNI I 1-Aff NOTES: XPR no N co W d',1 na zxs 20 1. THREAD MUST BE EMBEDED IN THE SIDE GRAIN OF A TRUSSES OR OTHER STRUCTURAL MEMBER 00 N I PULL OUT CALCUIATRONS FOR LAG BOLT I— b6a we") 04 cas 215 NOTE INTEGRAL WITH THE BUILDING STRUCTURE. H­ 11, 0,,,1 5po — 7a sp,,rO 1". Psf rch ThrOad c,pffi 266 Los 2. LAG BOLTS MUST BE LOCATED IN THE MIDDLE THIRD OF THE STRUCTURAL MEMBER. 1. 2s, 1­ SS Lan Ed% 4 511 Or' 11, Tht,,YJ D,fl, 31, CALCULATIONS WERE PERFORMED AND PERTAIN TO UNIRAC SUPPLIED PARTS ONLY. THIS CERTIFICATION EXCLUDES THE MODULE, 3, THESE VALUES ARE NOT VALID FOR WET SERVICE, 7eg m nit CONNECTIONS TO THE BUILDING STRUCTURES, AND EFFECTS ON THE BUILDING STRUCTURE COMPONENTS, THIS ANALYSIS WAS 4. THIS TABLE DOES NOT INCLUDE SHEAR CAPACITIES. IF NECESSARY, CONTACT A LOCAL 0 vsPkF'I,0­ 1�f 'S'L" Lg'Ifl,R`�`­red Re� Sou 4717 DEVELOPED ASSUMING A MEAN BUILDING HEIGHT OF LESS THAN OR EQUAL TO 30 FEET. ALL INFORMATION, DATA AND ANALYSIS ENGINEER TO SPECIFY LAG BOLT SIZE WITH REGARD TO SHEAR FORCES. CONTAINED WITHIN ARE BASED ON, AND COMPLY WITH THE FOLLOWING: Ar—ble Pd1I 0Of Sf,,,,,gh Pr� BOIr 798 5, INSTALL LAG BOLTS WITH HEAD AND WASHER FLUSH TO SURFACE NO GAP). DO NOT _�q B.11 Pril Out Sl­,Ih SIFO, Ois- i 68 i. 2018 INTERNATIONAL BUILDING CODE. BY INTERNATIONAL CODE COUNCIL, INC_ 2017 OVER -TORQUE. 2. 2020 FLORIDA BUILDING CODE, BY INTERNATIONAL CODE COUNCIL, FBC 2020,7TH EDITION. 6. WITHDRAWAL DESIGN VALUES FOR LAG SCREW CONNECTIONS SHALL BE MULTIPLIED BY 1 ASCE/SM 7-16 MINIMUM DESIGN LOADS FOR BUILDINGS AND OTHER STRUCTURES. BY ASCE. 2015 APPLICABLE ADJUSTMENT FACTORS IF NECESSARY. SEE TABLE 10.0.1 IN THE AMERICAN WOOD Or- UNIRAC ROOF ATTACHMENT LAG SCREW is X 3'2" 4. 2015 ALUMINUM DESIGN MANUAL, BY THE ALUMINUM ASSOCIATION. 2015 COUNCIL NDS FOR WOOD CONSTRUCTION. MANUFACTURER: ECOFASTEN SOLAR 1 MODEL: I 8-LB-5/16X3-1/2 21 ALLOWABLE LOAD: 56 PSF SOLARMOUNT UNIVERSAL AF STANDARD SYSTEM COMPONENTS To k. "1 -1 orl� 11 INSTALLATION GUIDE' NOTEINSTALL MID CLAMPS BETWEEN WA ie 0 , MODULES AND END CLAMPS AT THE END OF as 0 EACH ROW OF MODULES, RAIL SUPPORTS PV MODULES. USE AT LEAST TWO PER ROW OF MODULES. PRODUCTS:320246M ALUMINUM RAILS SHOULD ALWAYS BE s RAIL SPLICE: NON STRUCTURAL SPLICE JOINS, ALIGNS. AND ELECTRICALLY BONDS RAIL SUPPORTED BY MORE THAN ONE FOOTING SECTIONS INTRO SINGLE LENGTH OF RAIL. FORMS EITHER A RIGID OR THERMAL ON BOTH SIDES OF THE SPLICE. EXPANSION JOINT, 41N. LONG, PRE -DRILLED. 'A7 ON F is qf, �s 0 PRODUCT# 303019M -A, SELF -DRILLING SCREW: (NO. 12 X %`) USE 4 PER RIGID SPLICE OR 2 PER EXPANSION ') P, JOINT, STAINLESS STEEL. SUPPLIED WITH SPLICE. IN COMBINATION WITH RIGID SPLICE. PROVIDES RAIL TO RAIL BOND. N At- 0 L-FOOT: USE TO SECURE RAILS THROUGH ROOFING MATERIAL TO BUILDING -e STRUCTURE. REFER TO LOADING TABLES OR U-BUILDER FOR SPACING, L-FOOTT-BOLT (','x %") USE ONE PER L-FOOT TO SECURE RAIL TO L-FOOT. STAINLESS 4 STEEL. SUPPLIED WITH L-FOOT. IN COMBINATION WITH FLANGE NUT, PROVIDES (DL5088 _0O ELECTRICAL BOND BETWEEN RAIL AND L-FOOT. SERRATED FLANGE NUT (',"I: USE ONE PER _-FOOT TO SECURE AND BOND RAIL TO 12.7.2023 LANDSCAPE ORIENTATION L-FOOT. STAINLESS STEEL, SUPPLIED WITH L-FOOT MA SM STANDARD RAIL MODULE ENDCLAMP: PROVIDES BOND FROM RAIL TO ENCLAMP. PRE -ASSEMBLED SM LIGHT RAIL ALUMINUM CLAMP. SUPPLIED WASHER KEEPS CLAMP AND BOLT UPRIGHT FOR EASE OF ASSEMBLY, PRODUCT# 30202 1 C M.ALVAREZ MODULE MIDCLAMP: PRE -ASSEMBLED CLAMP PROVIDES MODULE TO MODULE AND MODULE TO RAIL BOND. STAINLESS STEEL CLAMP AND T-BOLT. PRODUCT#:302027C N-T.S. MICROINVERTER MOUNTING BOLT PRE -ASSEMBLED BOLT AND NUT ATTACHES AND Wrenches and Torque Anti -Seize: BONDS MICROINVERTER TO RAIL. WASHER AT BASE KEEPS BOLT UPRIGHT FOR EASE OF Seat Bmd' 500 STRUCTURAL DIAGRAM W,.r.h side Rd­­dbd Stainless steel hardware can seize up, a process ASSEMBLY. PRODUCT# 008013S A IL" & TORLde (ft-lbsi called galling. To significantly reduce its likelihood: CALCULATIONS 114'H00 1 1, Apply minimal lubricant to bolts, preferably NOTE- (POSITION INDICATOR) T-BOLTS HAVE A SLOT N THE HARDWARE END Hardware 0T16 CORRESPONDING TO THE DIRECTION OF THE T-HEAD, - r 3/8'Handwert, 0 9/16" Anti -Seize commonly found at auto parts stores On, PORTRAIT ORIENTATION 912 Hardware 0 5116' 10 2- Shade hardware prior to Installation, and SYSTEM ANCHORAGE Torques are red designed for use with wood connectors 3. Avoid spinning stainless nuts onto bolts at high SEAL BOND SCALE NTS 'w/Anti-Seize. s500 seed. pS-3 ram. g r r�Ilk I' 00 loll; = c.. -s: ��..� rw - r r" r' " r r := -00 � x ".:�. � a:.� �. 2 � A � �, 4:.� h � a SOLARMOUNT is ther - 1 is . °rf _..r..k is d ..f ,, .., for an eater,faster ..,u :J._.5 a, experience, .<n y.. L>sixM_r .-.w a molutionary universal clamps, „m FY SHKfi FR ."l ✓ r_ j r :3 rt £ ion ",,-,,d 2✓ ,,� air .F, r?.^.. F. is S A . a e, b New it lniproved THE PROFESSIONAM CHOICE With !Superior Aesthetic-, NOW FEATURING FLASHKIT PRO 10 f ; HA,URIaG ,< SHED & SEAL TLc motov NOW WIT. UNIIVERSAL MIDCLAMPS Accornmahles 301a m 51mm module frames One 1,001, one person installs are here! 11 Ill ph y m »..�.1' err CONTACT US. 6753 KINGSPOINTE PARKWAY SUITE 111 �°sue ORLANDO FL.32819 USA TEL +1 Anv7-308-0099 englreennar{Dwlndmarhame an' < W cep) 7 pry dW Q LL 00 01) tUj 3M 3: �� > 0 oI AN W 00 N a �x f�U TEE op I� DL5088 iZZ N= MA M. ALVARE=Z � - N s_ DATASHEETS 8 LABELS SOLAR Ji J r,,- BONDING CONNECTION GROUND PATHS I J. AT P A G E S' ALL -------- -S-M-MOUNT --------------------------------------------------------------------------------------- D/ ------------ PONDING MIDCLAMP ASSEMBLY Stainless steel MidcLarnp points, 2 per module, pierce module frame anodization to bond moduLe to module through clamp. Serrated flange nut bonds stainless steel clamp to staintess steeL T-bolt 0 Serrated T-bolt head penetrates rail anodization to bond T-bolt, nut, clamp, and modutes to grounded SM raiL ENDCLAMP ASSEMBLY Serrated flange nut bonds aLurninum EndcLamp to stainless steeL T-bott Serrated T-bolt head penetrates rail anodization to bond T-bolt, nut, and EndcLamp to grounded SM rail 110� � � MM' QBonding Hardware creates bond between splice 0 '0bar and each rail section 0 Aluminum splice bar spans across rail gap to create rail to rail bond, Rail on at Least one side of splice wiLL be grounded, RAIL TO L-FOOT w/BONDING T-BOLT 0 Serrated flange nut removes L-foot anodization R to bond L-Foot to stainless steeL T-boLt Serrated T-bott head penetrates raiL anodization to bond T-bolt, nut, and L-foot to grounded SM rail RACK SYSTEM GROUND WEEB washer dimpLes pierce anodized rail to create bond between raiL and Lug -0 Solid copper wire connected to Lug is routed to provide finaL system ground connection. CONTACT US: 6753 KINGSPOINTE PARKWAY SUITE 111, ORLANDO FL, 32819 USA TEL 11+07-308-0099 engmenrinaldwindmarhome.com 06o 0 < N g 0 CY) LL W 00 N o .. . . .. .. .... .1=4 LV 1.0 % STATE OP 0 R I 0 exy! A' DL5088 123.2023 MA M.ALVAREZ NLT, S DATASHEETS LABELS S-5 CONTACT US: 6753 KINGSPOINTE g, g, PARKWAY SUITE i E 111 On" All I ORLANDO FL, 32819 USA . . . . . . . . . . . . . . . g& TEL +1407-308-0099 S M BONDING CONNECTION GROUND PATHS X ,-5 g �p,�� g �g >1 rN P 'S Al ISO 1-11 '01", 1 -g/, N 'NS 1 ALLI 6 U I U kas PAGE --------------------------------------------------------------------------------------------------------------------------------------------- ELECTRICAL CONSIDERATIONS REQUIRED ONLY FOR TEMI SOLARMOUNT is intended to be used with PV TEMP BONDING DURING ARRAY M TE CE modules that have a system voltage Less than or equal to 1000 VDC. For standard system grounding a minimum 10AWG 105'C copper grounding conductor shouLd be used to ground a 1000 ca 0 LO LU VDC < CYI -K, system, accor ding to the National. ELectric Code 0 1 1 'n U U) (NEC). It is the instaLLer's responsibilLity to check LocaL < _J codes,which mayvary.See beLow for interconnection < co W Z: _J T Cr A-CkZ" LA - information. TEMPORARY BONDING CONNECTION DURING ARRAY MAINTENANCE When removing modules for repLacement or system maintenance, any moduLe Left in place that is secured with a bonding MidcLamp wiLL be properLy grounded. If a moduLe adjacent to the end module of a row is removed or if any other maintenance condition Leaves a mod uLe without a bonding mid cLamp, a temporary bonding connection must be instaLLed as shown • Attach Rsco SG134 to wall of rail • Attach lLsco SGB4 to module frame • install solid copper wire jumper to lLsco Lugs N 0 co 5- N CO W INTERCONNECTION INFORMATION co N There is no size Limit on how many SOLARMOUNT & PV moduLes can be mechanicaLLy interconnected for any given configuration, provided that the instaLLation meets the requirements of E Pq building and fire codes. c" No . . .... .... GROUNDING NOTES V ICY The instaLLation must be conducted in accWance U. , STATE OF t4F with the NationaL Electric Code (NEC) :1 af%Jh6 R I oW.- authority having jurisdiction. PLease refer to thp�*J- 01 resources in your Location for required grounding Lub", quantities specific to your project. DL5088 The grounding / bonding components may overhang 12.7,2023 parts of the array so care must be made when waLking around the array to avoid damage. N4. ALVAREZ N - T- S, AF Conductor fastener torque values depend on DATASHEETS conductor size. See product data sheets for correct LABELS torque vaLues. 1- �I - S-6 THE IDEAL SOLUTION FOR: 69 Rooftop arrays on residential buildings Engineered in Germany CONTACT US: 6753 KINGSPOINTE F, E PARKWAY SUITE 111, 74.0in x 41.1in x 1,261n (incliding frame) ORLANDO FL, 32819 USA (I8779mm x 1045mm x 32mm) TES. +1407-308-0099 48.5lbs (22.0kB) ally are- shessec glass wrth zng,reexinn�wirxlmarfrnme cam O.!3mC3,2mm)therm. stri-i-reflection te--hriology Fr— — I i or Composite vim ar i—I Black arodl2ed aluminum C3, a 6 x 22 rocriocrystalfine Q,AN-1 UM solar half cells 2.09-3.98ir x 1.26-2,36Ir x 0,59-0,71ir (53-101mrnx32-60mm, 15-18mor), iP67. wit, bypass diodes 4 huM2 Solar cable: .49,2ir (1250mrni, >49.2ir (i2fsOmm) axa Stsiubli MC4, IP68 �-A POWER CLASS 385 390 395 400 406 ry P-P [WI 385 390 395 400 405 06 0 Lo CO M 1, [Al 11.04 11 .07 11,10 1114 11,17 0 cy) y, vlc [v] 45, 19 45.23 452 7 45,30 45,34 _j N U_ < 0 N < 1'.. fAj 10,65 10.7! 10.77 am 10�83 OP < U TOP WAND PV V1­1 [VI 36.36 36.62 3713 37�39 LL o,✓ < I arl v 19,6 y201 >204 20,6 tl3U) < W _r ✓ooOK %k 2021, arr 0 CELLS 288.8 292r6 2963 3001 303.8 T_ 3: [Al 8,90 8.92 8,95 8,97 9,00 0 N in _0 V', IV) 42.62 4265 4269 42,72 4236 CY) M oo N 11-1 [Al 8.35 8L4&46 &5' 8.57 Q,ANTUM DUO Z Technology with zero gap cell tayout V", IvIl 3459 34,8i 3503 35.25 35,46 boosts module efficiency up to 20.9 %a. =Messuemert tolerances P,­±3%, I— V,,=5%a,,STC 10O0V1J/nq%25±2'C,AM 1 Saccording trtiEC 60904-3-280OW/r,,NMO,,-,spec,ru,AM 1,5 0 CELLS PERFORMANCE WARRANTY PERFORMANCE AT LOW IRRADIANCE 7, Q CELLS is the first solar module manufacturer to pass the most compreden- Atleas %*kof norninallsowerduring first yea, Thereastal max. 0.5% sive quality programme in the industry: The new "Quality Controlled PV' of deg,adstion pe- year, At letai 93,5% r W the independent certification institute TOV Rheinland. of normnai povver on to 10 years. A, X5, sasz86%aIromcalPower uPns v. 25yefns. A Tr�, 7' t- , t, Ali da?a wN rueavuremnl hNsnanc- Optimal yields, whatever the weather with excellent as. P'll wivraies in accordarveMih low -light and temperature behavior. ✓ teuns of the Q CELL S issuer, ofyou, restive.......... "I'll, ales organ s country, - , I - Typical t-odule Peroornance under ow irradiancecon,y1ions itir , 1", Long-term yield security with Anti LID Technology, Anti RID companson to STC co ons(25-C, 1OOOw1rn1) ae� " Technology'. -lot-Spot Protect and Traceable Quality Tra.Qlm. TEMPERATURE COEFFICIENTS 0 STATE .0 7* [%IK] NMOT ['Fj 109 L 5A (4� P R High-tech aluminum alloy frame, certified for O J � , „L high snow (540OPa) and wind loads (40001ca).f t IV] 1000 (EC)/1000 (UL) Class 11 [A DCJ 20 TYPE 2 Inclusive 25-year product warranty and 25-year 4F '175 (3600 Pa)! (2660 Rai -0up to 185'F linear pantormance warranty'. fibo/ft] 113 (540OPa)/84(400OPa) (.-40'C up to i 85°C) E)L5088 API tesi condrions according to IEC/ i S 62804-1,2015. oteiliod A l- lbOOV, 96ru 'See installation Manuel Sae d3hi steet or"ea, for fi.,rlhsr rJortrohos 12.7.2023 ✓F gy - C E L L S & AR Ha 0 CELLS America lm. 400 Spocir urn Center Dr've. Suite 1400. Pvne, -CA, 92618, USA I D-1 pe.,.,-;aton,com General Duty Cartridge Fuse Safety Switch DG222NRB UPC:782113144221 Dimensions: • Height: 7 IN • Length: 6.41 IN • Width: 8.4 IN Weight: 9 LB NotesWaximurn hp ratings apply only when dual element fuses are used. 3-Phase hp rating shown is a grounded B phase rating, UL listed, Warranties: - Eaton Selling Policy 25-000, one (1) year from the date of installation of the Product or eighteen (18) months from the date of shipment of the Product, whichever occurs first. Specifications: • Type: General Duty/Cartridge Fuse • Amperage Rating: 60A • Enclosure: NEMA 3R • Enclosure Material: Painted galvanized steel • Fuse Class Provision: Class H fuses • Fuse Configuration: Fusible with neutral • Number Of Poles: Two -pole • Number Of Wires: Three -wire • Product Category: General Duty Safety Switch • Voltage Rating: 240V Supporting documents: • P,"atoolume 2-Commerciai Distribiuition • Drawina Datasel, -E-aton Spedf�cabon Sr ee' - DG229NRB Certifications: - UL Listed General Duty Product Description • 30-600A • Suitable for service entrance applications unless otherwise noted • Fusible and non -fusible switches are 100% load break and 100% load make rated • The continuous load current of fusible switches is not to exceed 80% of the rating of fuses employed in other than motor circuits. Non -fusible switches are 100% fully rated ® 200-600A features K-Series design • Horsepower rated ® Fusible and non -fusible switches. Single -pole S/N through four -wire; 120/240, and 240 Vac ® With Class R fuses, switches may be used on systems capable of delivering 100,000A rms symmetrical Note: Plug fuse switches are not service entrance rated. Bolt -on hub provision. Provided for general -duty switches in a NEMA 3R enclosure. See Page V2-T1- 14 for selection Application Description For residential and commercial applications. Suitable for light -duty motor circuits and service entrance, CONTACT US: Switching Devices 6753 KINGSPOINTE PARKWAY SUITE 111, Safety Switches ORLANDO FL, 32819 USA TEL +1407-308-00% engineering @windrnarhome.corn Contents Description Page lt4 Product Overview .... ........ ........ V241-2 General Duty ... ...... ... V2-Tl-25 Standards and Certifications V2-T1-26 Product Selection, . ............... ........ 1/2-T1-27 Dimensions .............................. V2-T1-29 Heavy -Duty .................... V2-T1-30 Heavy -Duty Double Door Safety Switch __ ... ... V2-T1-39 Six -Pole Switches. . . ......... 11241-43 Double -Throw Switches ... V241-46 CD Envirol-ine Stainless Steel Switch ................ V2-TI-53 06 Window Switches. . ... ........ V2-T1-57 Receptacle Switches ..................... V2-Tl-60 Z Non -Metallic KRYDON Switch. . ..... V2-T1-62 < N 0 LL Shunt Trip Safety Switch . V2-Tl­- I-65 N < - < LL U) NEMA 7/9—Hazardous Location Disconnect Switch V241-68 LL _j Quick -Connect Switches .. _ . _ . . .............. V2-T1-70 Solar Disconnect Switch ......... .... .... ..... V241-75 fit Mill -Duty Rated, Heavy -Duty Safety Switch, . ....... V2-T1-77 >_ Heavy -Duty Fusible Safety Switches Accepting M CUBEFuses . ...... ............. V2-T1-79 0 CO UJ CL N Elevator Control Switch. . ...... V2-T1-82 00 NJ Auxiliary Power Heavy -Duty Safety Switch . V2-T1-85 Left -Handed Safety Switch ..................... V2-T1-89 Heavy -Duty Surge Switch ................ V241-90 OEM Line Isolation (01-1) Switch ................. V2-T1-92 Pringle Bolted Pressure Switch . ... V2-T1-95 Type DS, Fusible and Non -Fusible ......... V241-98 Type Visi-Flex DE-10N .................. V2-T1-101 I- IT Flange Mounted —Variable Depth ... ........ ... V2-T1-105', MIT' Flange Mounted —Fixed Depth ......... V 111OUT F A' 11 111,t A I- N o, Features, Benefits and Functions General -Duty (Cartridge Fuse) % STATE OF Al ® Ample wire bending Clearly visible an6k 0 ', 4 0 R I space provides for accessible neutral & qS/ .......... easier installation where applicable AY A L,sE • Visible double -break quick- ® Visible ON/OFF indication make, quick -break rotary, * Tangential knockouts on blade mechanism 30-60A designs • Side opening door on * Ample wiring space DL5088 all enclosures * Double padlocking 12.7.2023 • Mechanically interlocked capability on 30-I00A 11111111-11 cover to prevent easy - Triple dlocking capability MA access when the switch pa1111-1 11 - is in the ON position on 200-600A M.'ALVAREZ • With Class R fuses, * Additional door locking N _T_S. switches may be used capability on systems capable of Bilingual English/Spanish DATASHEETS door label on 30-100A & delivering 100,OOOA rms LABELS symmetrical Tri-lingual nameplates D-2 u1j D' Cartrid -e Fuse soenerai t Safety Switch DG224NRK UPC:782113213&07 Dimensions: * Height.- 25-23 IN * Length: 10 IN * Width; 15-52 IN Weight:43 LB Notm Maximurn hp rat nigs apply only °&hen dual elemen,t fusesare used, 3-Phase hp rating sha-pm is a grounded B phase rabnq; UL lfsied. Warrant ies-- Spec ificzlions; - Type: Gieneral Dut� y.fCartfi4ge Fuz-e - Ainperage Rating; 2(-';CA - Enclosure: NEMA 3R - Enclosure Matefial: Pamted galvanized steel - Fusee Claiss Provision: Class H fusss - Fusc- Configuratiow Fusible%poth n4eutra1 - Numbef Of Poles, Two -pole - Number Of Wires: Threle—wirp- - Product Category: G3,u-neml C)uty Safet/ &'I.Ach - Voltage Rating: 240V Supporting documents; Certifications: - UL Listed Product compilance. No Data M 1 V - G Eaton. All rights reserved. CONTACT US: Switching Devices 6753 KIN PARKWAYGSPOINTE SUITE 111, ORLANDO FL, 32819 USA CC Safety Switches TEL I 407-10NM engineenng@wndmarhorne,corr, General Duty Product Description • 30-600A • Suitable for service entrance applications unless otherwise noted • Fusible and non-f usible switches are 100% load break and 100% load make rated • The continuous load current of fusible switches is not to exceed 80% of the rating of fuses employed in other than motor circuits. Non -fusible switches are 100% fully rated ® 200-600A features K-Series design • Horsepower rated ® Fusible and non -fusible switches. Single -pole S/N through four -wire-, 120/240, and 240 Vac • With Class R fuses, switches may be used on systems capable of delivering 100,000A rms symmetrical Note: Plug fuse switches are not service entrance rated - Bolt -on hub provision. Provided for general -duty switcGI hes in a NEMA 3R enclosure. See Page V2-Tl- 14 for selection Application Description For residential and tal commercial applications. OEM Contents Description Page Product Overview ............................ V2-T1-2 General Duty ...... ........ V2-T1-25 Standards and Certifications ................. V2-T1-26 Product Selection. ....... ...... V2-TI-27 Dimensions ........ ......... ......... V2-T1-29 Heavy -Duty ....... V2-T1-30 Heavy -Duty Double Door Safety Switch ........... V2-T1-39 Six -Pole Switches. . . ........ V2-T1-43 Double -Throw Switches ... ............. ... V2-T1-46 (D EnviroLine Stainless Steel Switch ................ V2-T1-53 r) M Window Switches. ........ .... V2-T1-57 M Lij co Receptacle Switches ... ......... V2-T1-60 :7 Non -Metallic KRYDON Switch. . .... V2-T1-62 N 0 LL Shunt Trip Safety Switch . . ........ V2-T1-65 < NEMA 7/9—Hazardous Location Disconnect Switch V2-T1-68 U_ LL Quick -Connect Switches ....................... V2-T1-70 < _j Solar Disconnect Switch .... V2-T1-75 uJ 7- = Mill -Duty Rated, Heavy -Duty Safety Switch.. n- V2-TI-77 < < Heavy -Duty >- Fusible Safety Switches Accepting = 2: CUBEFuses. . .......... V2-T1-79 0 =4 0 000 LCLU Elevator Control Switch ..... .... V2-T1-82 oo N Auxiliary Power Heavy -Duty Safety Switch ......... V2-TI-85 Left -Handed Safety Switch ............ ........ V2-T1-89 Heavy -Duty Surge Switch . ...... ........ V2-T1-90 OEM Line Isolation (OLI) Switch. , .. , . , . . . . ..... V2-T1-92 Pringle Bolted Pressure Switch . . . .............. V2-T1-95 Type DS, Fusible and Non -Fusible ..... V2-T1-98 Type Visi-Flex DE -ION ....... ........... V2-T1-101 Flange Mounted —Variable Depth . V2-T1,40$`: Flange Mounted —Fixed Depth. . ... V2, IT8 C 4-, 3 . sEd&i, 11"Iri,41,11, Features, Benefits and Functions STATE OF Z General -Duty (Cartridge Fusel • Ample wire bending Clearly visible ands, -'.-n ��O R I space provides for accessible neutral le IJ/o AL� easier installation where applicable • Visible double -break quick- - Visible ON/OFF indication make, quick -break rotary * Tangential knockouts on blade mechanism 30-60A designs • Side opening door on - Ample wiring space DL5088 all enclosures * Double padlocking 12.7.2023 • Mechanically interlocked capability on 30-100A cover to prevent easy - Triple padlocking capability access when the switch on 200--600A M. ALVAREZ is in the ON position , Additional door locking ® With Class R fuses, capability switches may be used - Bilingual English/Spanish on systems capable of door label on 30-100A DATASHEETS delivering 100,000A rms LABELS symmetrical a Tri-lingual nameplates D-3 00-11 1 we 0% 0- ga P, ., &A ed 111E.: n 11-J, 2 9 s1,91 1 —k/p �& 1-111 ,-3-p rM1 C1-0111 11 1V 8 1'o learn more about Enphase offeirings, visit enphase.caim The high-powered smart grid -ready P i,va 'Q7A Micr-11"'J" dramatically simplifies the F­­,, v, a, c I installation process while achieving the highest system efficiency for systems with 60-cell and 72-cell modules. Part of the Enphase IQ System, the IQ 7A Micro integrates with the Enphase IQ Envoy", Enphase IQ Battery', and the Enphase Enlighten" monitoring and analysis software. The IQ Series Microinverters extend the reliability standards set forth by previous generations and undergo over a million hours of power -on testing, enabling Enphase to provide an industry -leading warranty of up to 25 years, High Power Peak ou'put owwef 366 \/A ivii 240 VAC and 295 VA ro208 VAIC Easy to install Lightweigh," and sirnp�e Faster iristaliation erith n1olproved, lighter two -wire cabiring Built- inrapid shutdcivin cotopliant (NEC 2014, 201 -7 & 2020) Efficient and Reliable OpWnized for Ngh powered 60-cell and 72-cell moduies �,fighest CEC efficlencv of 97% More than aruff. ron hours oftesting Class 11 double-insudated encloswe UL iisled Smart GIrild Ready Cot"" with advancpd gnd support, voltage an,d fiequency"Ide- through requiHemerits Erivoy and intenlet connection required Configurable fo, or ying grkdl proffles Meets CA Rude 21 WL 1741 -SA) ENPHASE Enphase IQ 7A Microinverter CONTACT US: 6753 KINGSPOINTE PARKVVAY SUFTE 111, lNPUT (DC) , IQ7A-72-2-US ORLANDO FL, 32819 USA Commonly Used rno6uie painir,gs, 295 7€-460 W + TEL 1407-308-0099 Modrile cornpaitibility 60-c0l, 66-celi and 72 oeli PV rnoles du Maxifn,um Enput DO voltage 58 V ergineerim(amindmarhome,com Po,vwr nt tracking voltage range18 V-58 V A Mir,"Max roart voltage 33 V / 58 V Max DC short circuit cun,ent lmoduqe lsc)" 15 A OvervoRage class DC purr t U DC port backfeed current 0 A PV array configurafion I a 1. ungrounded army-1 No additionai DC side protection resitmired, AC side protection rpquires max 20A par branch circurt OUTPUT (At @ 240 VAC @ 208 VAC Peak output power 366VA 295VA Mpxirnurn conlinuous output power 349 VA 290 NIA, Norm nal (L-Lr voltage,ftangel 240 V / 211 -264 V 208 V / 1183­22`9 V Maximurn confinuoUs output current 1,45 A (240 VAC) 1_3q A (208 VAQ l"'Orninal frequenc,y 60 ` CD -jz Extended frequency range 47-68 Hz 06 < co 0 LO < AC shon chcrAt fault current over 3 cycles 5.8 Arms a LIJ M Maxim.,urn units rjer 201 A (L-0 branch circwt` 11 (24 0 VAC) I 1 (2 0 8 V A C 0 < Z _j I I I < r-4 0 LL Overvortage class AC port Ili N AC port backfeed currenLL _jt 18 mA LL cryco Power factor setting 10 < Power factor (adjustaWc- 0leading 0.85 lagging EFFICIENCY @240 VAC @208 VAC < >- CEC weighted efficiency 97,0'v, 9 6.5 yi, T_ o MECHANICAL N CO 00 N Arnbient lefirtperature range -401C to �-601(3 RelatWe h1urnichty range.4 f 1 o 10 0 % (c on, d en a n (a',, Connector type: DC 6Q`7,6,272-24JIS) MC'4 0 D i n i en Si o n s ;H x W x,9,) 212mr-rt x 175 rn,"", x 30.2 om (withoot bracket, Weighn, 1.08 kg t2,38 lbsg Corflin.g Natural convPction No lans Approved for iaef lrocatrons Yes ­tz 1T1 x Polfutlem degree PD3 Enclosure C1a,ss if resistantpolyrneric enciosure & E n v i r o n rn c n t a i c a t e go r v i A a x p o au e rating NEMA Type 6 outdoor FEATURES Corm-nunrcation Power Line Ccam"Municaiion (PLC) T711 Monitor6. Enlighten Manager and MyEr"llighter, monitoring yyptions Cornpat�blevvrth Enphase 10 Envoy 10 and DC corvIectors have been evaluated anid approved by U1, for use, as Vii'VWbreaP 441 Disconnecting means The A( TATE OF dfisccoinect required by NEC 690, V R ii V Comsfiance 'A RWe 211 (UL 1741-SA) UL62',,09-1,UL174l�-:P-,P'547, FCC part lCDS-0003 Class B, CIAN/CSA-1`22.2 NO, `H'tj7,j 01 'a AJ A L Ti-.jS product Eli- Listedas PVRepidShut Down, NEC 204, NEC 2017, and NEC 2E2.3, secllon 690.12and C1121-2015 Rulle 64-218 Rapid Shundown o',PV Cystenns, fo; AC and DC conductors,,xvhen installed according manufaclurer's instruction,,s, r)L-5088 12.7.2023 y No enlfortv dDC/AC ra,!N, S",e 1hecQcnPat:Wity c, M it MA C ti�ak pirvver trackingvo,"tage range 38 V to 43 V 3 vlaxrmum, continut f DCcurent is 10,2A U. Vortage �arige carr be exsended bev7.:,.­,d nowrona� if re.r Qwed bv theuflMy, M.ALVAREZ 5 i rr,,€Tv may vary ReFerioiocaf recluinrrtent. to dee the, nurnvr of nnicrcmve�,es pler branch, i, arE-F, N.T.S. To learn more about E-nphase offerings, visit enphase.com DATASHEETS & c, J LABELS ENPHASE D-4 g e r 74 t A; SMWT 'J mmevol aa 1 Men hem F 1 0 v des p,ndin m r ml m , g ir d c A nsu,atn f, m C r A " i„ : I To " t .A. t e mvws W f", !cow nwas :Icon 0" TWVWr CLk" Wown 4v nc "M", , 10L !CC TV !y SISS, rV;nCh T,:U!� ENPHASEE 14� CONTACT US: Q o4/4C 6753 KINGSPOINTE Cmbiner ROOM SUITE 111. ORLANDO FL, 32819 USA NAODEL NUMBER TEL 1407-308-0099 s 0 sw Q bato an �S,17 fk 44� �4wvwjmn mv,,0403 AV45,mu. TwWasomms lwm Nun:"WWA Ochs "in a a,, FG �l M n— on 1 1 ZV TW— 14, ­ 1 1— A � ACUSWRMS AW REPLACEAAENT PART S wi —60ed a dwr s"xmn6� AD n I V 00 C 5 5, i ...... now&% E "n Wy �_A_ zon nk W t no ­Wl N*&W� YA" 0A EWOVEQ: C7 0"aluea-1 ;—COSA Erymgqm, BA M WNQmW i, PY) uj or) CA 41 Q U. <1 Lu W = EL < 31 ELECTRICAL SPEC IFWAVT�CINS N CO M h 00 N E. OF mvl: on, O wv�w h W40" t jv "W �V:y lam I.Potud gene a no-, W4 Pow mmm"­Po E NKC HANK A L DATA 0 1 All V 031 Z A= 10=1 my Q� t vmkm o—We V�: no STIATE OF go? vInn"r movlmd+ 1_. 40 R 11 1 �l Al fNITERW T CONNECT!GN OPTEDWS DL5083 Atz 91? Wo, RAA M. ALVAREZ C"Wiarm pc.xomv� VAR"10 01!Tv2W, WT.S_ to 1"z aw my, wz WA P WwwAy nemm, MIS cl DATASHEETS LABELS D-5 COMBINER BOX/ CIRCUITS! CONDUIT COMBINER BOX/ ENCLOSURES/ EMT ENCLOSURE ELEMICAL 51=K HAZARD TERM114ALS ON THE LINE AND LOAD SIDES MAY BE ENERGIZED IN THE OPEN POSITION NEC 690.13(B) I Roll: 596-00878 10-Pk: 596-00893 / Metal 5-Pk: 596-00921 Engravable 5-Pk: 596-00862 RN OFF PHOTOVOLTAIC AC DISCONNECT PRIOR TO WORKING INSIDE PANEL NEC 110.227(C) & OSHA 1910.145(i)(7) Roll: 596-00499/10-Pk: 596-00664 Metal S-Pk 596-00832 SOLAR INSTALLER INFORMATION WINOMAR SOLAR 407-308-4999 6753 Kingspointe Pkwy, Suite 111 Orlando, FL 32819 NFPA 12015 SECTION 11.12.2.1.5 LABEL FOR: INSTALLER INFORMATION LABEL SIZE: 5" x 2" NEC 705,12(D)(3) & NEC 690.59 / Roll: 596-00495 '0-Pk: 596-0%65 / Metal 6-Pk: 596-00833 A/C DISCONNECT, BREAKER, POINTS OF CONNECTICrN NEC 690 13(B) / Roll: 596-00878 10-Pk: 596-00893 / Metal 5-Pk: 596-00921 NEC 690,54 / Roll: 596-00892 / 10-Pk: 596-00882 pHp4P4eGTAlC 0.0 EGS Engravabie 5-Pk: _.... 596 00923 _........... PV SYSTEM LABELING REQUIREMENTS: NEC 2017 ARTICLE 690 AND 2020 FFPC 7TH EDITION. 2 BUILDING/ 3 EMT, CONDUIT STRUCTURE *((REFVE MA ERIR REQUIRED} 4 MAIN SERVICE PANEL NEC 705.10 & NEC 690,56(B) Roll: 558-00350 8 INVERTER AWARNING THE DISCONNECTION OF THE GROUNDED CONDUCTOR(5) MAYRESULT IN OVERVOLTAGE ON THE EQUIPMENT NEC 690.31(D / Ralf: 596-CJ9323 10-Pk: 596-09324 / Metal 5-Pk: 596-00924 NEC 690.54 / Roll: 596-00892 / 10-Pk: 596-00882 mmm Engravable 5-Pk 596-00923 NEC 690.31(G)(3)(4) I Roll: 596-00206 / 10-Pk: 596-00678 NEC 705,12 (B)/2)(3)(b) NEC 690.31(G)(1) i Roll: 596-00257 NFPA -1 1IA2.2.1,3-1 AND FFPC 11-12.2.1,3.1 THE LABELS OR MARKINGS SHALL BE VISIBLE AFTER INSTALLATION, THE LABELS SHALL BE REFLECTIVE AND SHALL HAVE ALL LETTERS CAPITALIZED WITH A MINIMUM HEIGHT OF 3/8 IN (9.5 MM) WHITE ON RED BACKGROUND. PV POWER CIRCUIT LABELS SHALL APPEAR ON EVERY SECTION OF THE WIRING SYSTEM THAT IS SEPARATED BY ENCLOSURES. WALLS, PARTITIONS, CEILINGS. OR FLOORS. SPACING BETWEEN LABELS OR MARKINGS, OR BETWEEN A LABEL AND A MARKING SHALL NOT BE MORE THAN 10 F T (3M) LABELS REQUIRED BY THIS SECTION SHALL BE SUITABLE FOR THE ENVIRONMENT WHERE THEY ARE INSTALLED. 11 RAPID SHUTDOWN SHUTDOWN SWITCH TO THE"OFF' POS€FION TO SHUT DOWN ENTIRE P',d SYSTFfA �^rrnsa � s crx� "s NEC 690.13(B) I Roll: 596 00&78 10-Pk: 596-00893 / Metal 5-Pk: 596-00921 TURN OFF PHOTOVOLTAIC C DISCONNECT PRIOR TO WORKING INSIDE PANEL NEC 110-271C) & OSHA 1910.145(t)(7) Roll: 596-004991 10-Pk: 596-00664 MM.15-Pk: 596-0083.2 NEC 690.54 / Roll: 596-00892 / 10-Pk: 596-03882 JIM Engravable, 5-Pk: 596-00923 NEC 710-15(C) & 692.9 (C) I Roll: 596-00591 10-Pk: 596-006% t Metal 5-Pk: 596-00837 NEC '690.15 (CI & NEC 690.33(E)(2) Roll: 596-002441 10-Pk: 596-00671 NEC 690A 3 (F), NEC 705.12(6)(3-4) & NEC 690.59 Roll: 596-00587 / 10-Pk: 596-00666 Metal 5-Pk: 596-00834 NEC 705.12(B)(3-4) & NEC 690.591 Roll: 596-00495 10-Pk'. 596-006651 Metal 5-Pk: 596-00833 NEC 70512 T)(2)(c) / Roll: 596-00883 10-Pk: 596-00884 / Metal 5-Pk: 596-00917 CONTACT US: 6753 KINGSPOINTE PARKWAY SUITE I11. ORLANDO FL, 32819 USA TEL: +1 407-308-0099 '.. engineerma(a;windm rhome cnm CD `8 Q LO CQ � J LL U) < ..I T 0 CL N cra I.I.I 00 ICI w O N i T MAIN SERVICE DISCONNECT �LEIGAL SF#C>CIC HA?ARD x u .,E _,rF ;�e,,.� TERMINALS ON THE LINE AND e, LOAD SIDES MAY HE ENERGIZED IN THE OPEN POSITION� t NEC 690.13(B) / Roll: 596-00878 10-Pk: 596-00893 / Metal 5-Pk: 596-00921 .. .... " `" tJ X �22TIIkT ff TURN OFF PHOTOVOLTAIC AC DISCONNECT PRIOR TO��,Nr� WORKING INSIDE PANEL DL5088 NEC 110,27(C) & OSHA 1910.145(f)I7)- RotL 596-00499 / 10-Pk: 596-00664 12.7.2023 Metal 5-Pk: 596-00832 mMA M-ALVAREZ N-T-S. NEC 690,13(6) / Roll: 596-00243 DATA54iEETS 10-Pk: 596-00675 / Metal 5-Pk: 596-00860 & LABELS