Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
23-7116
Address: 6806 Wagon Trail Street ZEPHYRHILLS, FLORIDA 33541 Phone: (347) 735-1792 City of Zephyrhills 5335 Eighth Street Zephyrhills, FL 33542 ELCMISC-007116-2023 Phone: (813) 780-0020 Fax: (813) 780-0021 Issue Date: 10/30/2023 Building Valuation: $0.00 Electrical Valuation: $58,725.00 Mechanical Valuation: Plumbing Valuation: Total Valuation: $58,725.00 Total Fees: $333.62 Amount Paid: $333.62 Date Paid: 10/30/2023 12:27:25PM Electrical Permit Fee $333.62 Contractor: MOMENTUM SOLAR - SOLAR Contractor: MOMENTUM SOLAR -ELECTRICIAN C) 72 REINSPECTION FEES: (c) With respect to Reinspection fees will comply with Florida Statute 553.80(2)(c) the local government shall impose a fee of four times the amount of the fee imposed for the initial inspection or first reinspection, whichever is greater, for each subsequent reinspection. may be found in the public records of this county, and there may be additional permit required from other governmental entities such as water management, state agencies or federal agencies. ef=lt nFrEOI'I accordance with City Codes and Ordinances. NO OCCUPANCY BEFORE C.O. NO OCCUPANCY BEFORE C.O. CONTRACTOR SIGNATURE- PEfAIT OFFICEV PERMIT EXPIRES IN 6 MONTHS WITHOUT APPROVED INSPECTION CALL FOR INSPECTION - 8 HOUR NOTICE REQUIRED PROTECT CARD FROM WEATHER 813-780-0020 City of Zephyrhffls Permit Application Fax-813-780-0021 Building Department Date Received Phone Contact for Pon"Itfin ( 321 1 247 — 6073 #44 11411� as,ea,2_1111141 oww'Wwwwavis Owners Name MIGDALIA GRANDE Owner Phone Number 1 (321) 247-6073 Owner's Address 6806 WAGON TRAIL ST ZEPHYRHILLS 33541 Owner Phone Number 321-247-6073 Fee Simple Titleholder Name I Owner Phone Number Foe Simple Titleholder Address JOB ADDRESS 6806 WAGON TRAIL ST. ZEPHYRHILLS FL 33541 LOT # SUBDIVISION SILVERAIDO RANCH PARCEL ID# (OSTAINW PROM PROPERTY TAX NOTIOS) WORK PROPOSED M NEW CONSTR r__J ADD/ALT SIGN DEMOLISH INSTALL REPAIR PROPOSED USE SFR COMM OTHER TYPE OF CONSTRUCTION BLOCK FRAME STEEL DESCRIPTION OF WORK Installationof Photovoltaic Solar Panels on Rooftop BUILDING SIZE = SO FOOTAGE = HEIGHT =BUILDING r57,82.5 VALUATION OF TOTAL CONSTRUCTION =ELECTRICAL Lg00.00 AMP SERVICE PROGRESS ENERGY W.R.E.C. =PLUMBING 1$ =MECHANICAL 1$ VALUATION OF MECHANICAL INSTALLATION =GAS ROOFING SPECIALTY = OTHER FINISHED FLOOR ELEVATIONS FLOOD ZONE AREA =YES NO 4 #444044 0 #0 0, 0 BUILDER COMPANY LI!MBomenturn Solar SIGNATURE Cameron Christensen REGISTERED FEE CURREN N E���� Address 1 6210 Haffner Ave Ste 100 Odamdo FL 32822 License #ECVC57036�� ELECTRICIAN COMPANY Momutrttum Solar Matthew Franz REGISTERED SIGNATURE cor"'.. Address F6210 HaffnerAv. Ste 100 Orlando Fl. 32822 Liconso 0 PLUMBER COMPANY SIGNATURE RE131STERED L=Y / =N—FEE _CU.RRE_N=Y NEJ� Address F_ License III MECHANICAL COMPANY SIGNATURE F REGISTERED Y J N FEE ..... Address I License # OTHER COMPANY E;;;;; ,.cua� SIGNATURE REGISTERED Address License # RESIDENTIAL Attach (2) Plot Plans; (2) sets of Building Plans; (1) set of Energy Forms; R-O-W Permit for new construction, Minimum ten (10) working days after submittal date. Required onsite, Construction Plans, Stormwater Plans w/ Silt Fence Installed, Sanitary Facilities & I dumpster; Site Work Permit for subdivisions/laW projects COMMERCIAL Attach (2) complete sets of Building Plans plus a Life Safety Page; (1) set of Energy Forms, R-O-W Permit for now construction. Minimum ten (10) working days after submittal date. Required onsife, Construction Plans, Stormwater Plans w/ Silt Fence installed, Sanitary Facilities & I dumpster. Site Work Permit for all new projects. AD commercial requirements must meet compliance SIGN PERMIT Attach (2) sets of Engineered Plans. ****PROPERTY SURVEY required for all NEW construction. Directions: Fill out application completely. Owner & Contractor sign back of application, notarized If over $2SO1, a Notice of Commencement is required. (AIC upgrades over $7500) Agent (for the contractor) or Power of Attorney (for the owner) would be someone with notarized letter from Owner authorizing same OVER THE COUNTER PERMITTING (copy of contract required) Reroofs If shingles Sewers Service Upgrades A/C Fences (Plot/Survey/Footage) Driveways -Not over Counter If on public roadways -needs ROW 813-780-0020 City of Zephyrhills Permit Application Fax-813-780-0021 Building Department NOTICE OF DEED RESTRICTIONS: The undersigned understands that this permit may be subject to "deed" restrictions" which may be more restrictive than County regulations. The undersigned assumes responsibility for compliance with any applicable deed restrictions. UNLICENSED CONTRACTORS AND CONTRACTOR RESPONSIBILITIES: If the owner has hired a contractor or contractors to undertake work, they may be required to be licensed in accordance with state and local regulations. If the contractor is not licensed as required by law, both the owner and contractor may be cited for a misdemeanor violation under state law. If the owner or intended contractor are uncertain as to what licensing requirements may apply for the intended work, they are advised to contact the Pasco County Building Inspection Division —Licensing Section at 727-847- 8009. Furthermore, if the owner has hired a contractor or contractors, he is advised to have the contractor(s) sign portions of the "contractor Block" of this application for which they will be responsible. If you, as the owner sign as the contractor, that may be an indication that he is not properly licensed and is not entitled to permitting privileges in Pasco County. TRANSPORTATION IMPACTIUTILITIES IMPACT AND RESOURCE RECOVERY FEES: The undersigned understands that Transportation Impact Fees and Recourse Recovery Fees may apply to the construction of new buildings, change of use in existing buildings, or expansion of existing buildings, as specified in Pasco County Ordinance number 89-07 and 90-07, as amended. The undersigned also understands, that such fees, as may be due, will be identified at the time of permitting. It is further understood that Transportation Impact Fees and Resource Recovery Fees must be paid prior to receiving a "certificate of occupancy" or final power release. If the project does not involve a certificate of occupancy or final power release, the fees must be paid prior to permit issuance. Furthermore, if Pasco County WaterlSewer Impact fees are due, they must be paid prior to permit issuance in accordance with applicable Pasco County ordinances. CONSTRUCTION LIEN LAW (Chapter 713, Florida Statutes, as amended): If valuation of work is $2,500.00 or more, I certify that 1, the applicant, have been provided with a copy of the "Florida Construction Lien Law —Homeowner's Protection Guide" prepared by the Florida Department of Agriculture and Consumer Affairs, If the applicant is someone other than the "owner, I certify that I have obtained a copy of the above described document and promise in good faith to deliver it to the "owner" prior to commencement. CONTRACTOR'SIOWNER'S AFFIDAVIT: I certify that all the information in this application is accurate and that all work will be done in compliance with all applicable laws regulating construction, zoning and land development. Application is hereby made to obtain a permit to do work and installation as indicated. I certify that no work or installation has commenced prior to issuance of a permit and that all work will be performed to meet standards of all laws regulating construction, County and City codes, zoning regulations, and land development regulations in the jurisdiction. I also certify that I understand that the regulations of other government agencies may apply to the intended work, and that it is my responsibility to identify what actions I must take to be in compliance. Such agencies include but are not limited to: - Department of Environmental Protection -Cypress Bayheads, Weiland Areas and Environmentally Sensitive Lands, Water/Wastewater Treatment. - Southwest Florida Water Management District -Wells, Cypress Bayheads, Wetland Areas, Altering Watercourses. - Army Corps of Engineers -Seawalls, Docks, Navigable Waterways. - Department of Health & Rehabilitative Services/Environmental Health Unit -Wells, Wastewater Treatment, Septic Tanks. - US Environmental Protection Agency -Asbestos abatement. - Federal Aviation Authority -Runways. I understand that the following restrictions apply to the use of fill: Use of fill is not allowed in Flood Zone "W unless expressly permitted. If the fill material is to be used in Flood Zone "A", it is understood that a drainage plan addressing a "compensating volume" will be submitted at time of permitting which is prepared by a professional engineer licensed by the State of Florida. If the fill material is to be used in Flood Zone "A" in connection with a permitted building using stem wall construction, I certify that fill will be used only to fill the area within the stem wall. If fill material is to be used in any area, I certify that use of such fill will not adversely affect adjacent properties. If use of fill is found to adversely affect adjacent properties, the owner may be cited for violating the conditions of the building permit issued under the attached permit application, for lots less than one (1) acre which are elevated by fill, an engineered drainage plan is required. If I am the AGENT FOR THE OWNER, I promise in good faith to inform the owner of the permitting conditions set forth in this affidavit prior to commencing construction. I understand that a separate permit may be required for electrical work, plumbing, signs, wells, pools, air conditioning, gas, or other installations not specifically included in the application. A permit issued shall be construed to be a license to proceed with the work and not as authority to violate, cancel, after, or set aside any provisions of the technical codes, nor shall issuance of a permit prevent the Building Official from thereafter requiring a correction of errors in plans, construction or violations of any codes. Every permit issued shall become invalid unless the work authorized by such permit is commenced within six months of permit issuance, or if work authorized by the permit is suspended or abandoned for a period of six (6) months after the time the work is commenced. An extension may be requested, in writing, from the Building Official for a period not to exceed ninety (90) days and will demonstrate justifiable cause for the extension, If work ceases for ninety (90) consecutive days, the job is considered abandoned, OWNER OR AGENT I % VAT ILLX447 Subscribed and sworn to kLr allifirnried before me 10/23 by MIGD A GRADE Who is/are personally known to me or has/have produced DRIVERS LICENSE as identification, 9 -d-mcwyl 41* Notary Public Commission No. HH351297 LISA ANN KNOTE Name of Notary typed, printed or stamped Notar Public State of Florida hits Ann Knote My Commiesion HH 351297 04, 110, Expires ol/10/2027 Subscribed and sworn to (or affirmed) before me this ;eU 10/23 by Who is/ara personally known tome or has/have produced as identification, Notary Public Commission No, HH351297 LISA ANN KNOTS Name of Notary typed, printed or stamped 11 �1I "I'll, , 1111`11"', 1 Notary Pwbtic State of Florid A Lisa Ann Knote Expires 01/19/2027 Pro Custom Solar LLC 3096E Hamilton Blvd South Plainfield, NJ 07080 Re: Proposed Photovoltaic Solar Panel Installation Migdalia Grande 6806 WAGON TRAIL STREET ZEPIIYRI-IILLS, FL 33541 Dear Plan Reviewer: Mom Certification: I have reviewed the engineering testing reports for the racking and attachments to be used on this project and I certify that the products are capable of supporting the code required loads and are suitable for this installation when installed in strict compliance with the manufacturers printed instructions. Regarding the solar panel array installation on the above referenced project please note that an inspection was performed by a representative of the Architect/Engineer of Record, and analysis of the existing structure was conducted. There is adequate structural capacity for the installation of the array with the following recommendations: I . The array will be installed on the existing roof. The roof framing is constructed of 2"x4" wood trusses @24" o.c. spanning ITI 0" with a top chord length of 18'11 " with intermediate supports at 1/3rd points, making the effective longest span equals 7'6" with 1/2" plywood sheathing. The new array (See Site map by contractor) will add 2.63 Lb. Sf. overall to the roof. The existing structure is sufficient to support the new loads associated with the additional weight & wind resistance. No additional structural support is required for the roof structure. 2. The attachment system shall be secured to the roof and shall be in strict compliance with manufacturers printed instructions. The attachment system shall be UL 1703 approved tested. Provide water tight sealant at all penetrations. Attachments shall follow panel rows as specified by the system manufacturer's installation manual. The panel angle shall match the roof slope. Reference summary table below: Roof Type: Shingle Fastener Max Spacing (in.) Attachment System: "ROOFTECIFIR) "RT MINI 11" & "UNIRAC SM" Mounting Systems Wind Zone I Wind Zone 2 Wind Zone 3 Fastener Info: min, 5/16" x 4" long stainless -steel lags with a min. 48 24 24 embedment of 3" into the rafters 3. Solar Modules shall be UL-I 703 rated. Refer to manufacturers specifications sheets. 4. Positive drainage of the system shall be so as not to void the existing roof warranty, 5. All aspects of the installation shall comply with the Florida Administrative Code, 2020 Florida Building Code - Residential Seventh Edition, ASCE-7-16, 2020 Florida Building Code — Energy Conservation, Seventh Edition, 2017 National Electric Code, All Local Governing County and Municipal Ordinances adopted by reference or enacted by law. All components used meet the criteria of the Florida Solar Energy Center. 6. Please refer to the attached structural If you have any questions relating to this matter, p Michael S. Rezk, P.E. FL. Lic. No. PE95844 convenience, Thank you. Engineer -PE Pro Custom Solar LLC 3096B Hamilton Blvd South Plainfield, NJ 07080 Gravity Load Calculation Criteria Structural Design Loads per ASCE 7-16 Dead Loads = 10 psf + 2.6 psf (new solar panels) = 12.6 psf Roof Live Load = 20 psf Ground Snow Load/Live Load = 0 psf Wind Load Calculation Criteria Wind Loads per ASCE 7-16, Equation 29.4-7 Using an effective wind area of 10 SF, external pressure coefficient from Figure 303-A-1 Zone I = -36,5 psf Roof Slope = 20 degrees Roof Mean Height = 15 ft Zone 2 = -47.4 psf Basic Wind Speed = 140 mph Zone 3 = -54.7 psf Exposure = B Per section 2.4.1, ASD combo = D + 0 -6W: Zone I = 2.6 psf + 0. 6(-3 6.5 psf) = - 19.3 psf Zone 2 = 2.6 psf + 0.6(-47.4 psf) = -25.8 psf Zone 3 = 2.6 psf + 0.6(-54.7 psf) = -30.2 psf Check Attachment to Wood Truss Use 5/16 dia. Lag screw -vv/ 3" embedment into 2 in. wide roof rafter Lag Screw Spacing: Lag Screw Tributary Area: Zone I = 48" o.c. max Zone I = (48" o.c. max)/2 / 144 = 16 SF Zone 2 = 24" o.c, max Zone 2 = (24" o.c. max)/2 / 144 = 4 SF Zone 3 = 24" o.c. max Zone 3 = (24" o.c. max)/2 / 144 = 4 SF Lag Screw Forces: W = 266lb/in (Table 12.2A, 2015 NDS) Zone I = 19.3 psf x 16 SF = 309 lb < W', OK Cd = 1.6 (Table 2.3.2, 2015 NDS) Zone 2 = 25.8 psf x 4 SF = 103 lb < W', OK Ct = I (Table 2.3.3, 2015 NDS) Zone 3 = 30.2 psf x 4 SF = 121 lb < W', OK W'= W x embed x Cd x Ct W'= 266 lb/in x 3 in. xl.6 x I = 1276.8 lb powered by 6OVSBAR tZ BUSBAR CELL TECHNOL00Y CELL TEINiNOLOOY THE IDEAL SOLUTION FOR: 6nRooftop arrays on residential buildings BREAKING THE 20% EFFICIENCY BARRIER Q,ANTUM DUO Z Technology with zero gap cell layout boosts module efficiency up to 20.9 %. THE MOST THOR01113H TESTING PROGRAMME IN THE INDUSTRY Q CELLS is the first solar module manufacturer to pass the most comprehen sive quality programme In the industry: The new "Quality Controlled PW of the independent certification institute TOV Rheinland. INNOVATIVE ALL-WEATHER TECHNOLOGY Optimal yields, whatever the weather with excellent low -light and temperature behavior, ENDURING HIGH PERFORMANCE Long-term yield security with Anti LID Technology, Anti PID Technology', Hot -Spot Protect and Traceable Quality Tra.QTm. EXTREME MEAT HER RATING High-tech aluminum alloy frame, certified for high snow (5400 Pa) and wind loads (4000 Pa). 62,1 A RELIABLE INVESTTENT e,v, ' �'A -- Inclusive 25-year product warranty and 25-year linear performance warranty2. APT test conditions according to IEC/TS 62804-1:2015, method A (-1500V, 96h) See data sheet on rear for further information, 0 CELLS MECHANICAL SPECIFICATION Format 74.0in x 41.1in x 1.26in (including frame) _."_.-.,.48.51bs(22.Okg) �Weight (1879mm x 1045mm x 321 nm) �._ Front Coves 0.13in (3.2mm) thermally pre -stressed glass with � _ - anti -reflection technology Buck Cover Composite film Framr, Black anodized aluminum Cell 6 x 22 monocrystalline Q.ANTUM solar half cells junction Sox 2.09-3.98 in x 126-2.36in e 0.59-0.71in���" _ (53-101mm x 32-60mm x 15-18mar), IP67, with bypass diodes _ mm Cable ,- 4mm2 Solar cable, (+) a49.2in (1250mm), (-)>_49.2in (1250mm) -.Staubli Connector MC4; IP68 DEWLA "*e (16m r 096'(24.bmml T-(�--�E.3&'Id5mml ELECTRICAL CHARACTERISTICS F? POWER CLASS 386 300 388 400 405 MINIMUM PERFORMANCE Al STANDARD TEST CONDITIONS, S 3 C- (POWER TOLERANCE 5l'<r t-OW! � � Power a3 P4PPa Pr [W] 385 390 395 400 405 Short Circuit C turent' ,r�� � I, [A] � 11.04 11.07 11.10 11,14 11.17 - Chen Circuit Vtotnge" V.r IV] 4519 45.23 45.27 45.30 45.34 - Current at Stipp 1M , [A] 10.59 10.65� 10.71 1017 10.83 _ V'oftage «t Cvi V,", IV] 36,36� 36,62 36.88 37,13 37.39 Efficiency-� q� [%] _19.6 � =19.9 ?20.1 >20.4 220.6� MINIMUM PERFORMANCE -� AT NORMAL OPERATING . t�i DITiONS, NNIOTS Power'at`1PP PM [W] � 288.8 292.E 296.3 �8,95 300.1 303.8 E Short Circuit Current ISO (A) 8,90 8.92 8,97 9,00� Open CirQ.u't Voltage � Vo" IV] 42.62 42.65 42.69 42,72 42.76 Current atMPF� Iw, [A] 8,35 8.41 � 8.46 8,51 8.57 Voltage at M'p- � VMe, IV] 34.59 � 34.81 35.03 35,25 35.46 'Measurement tolerances Pµ,r t3%; Isr; V t5% at STQ 1000 W/m2, 25±2°C, AM 1.6 according to IEC 60904-3. 2800W/m2, NMOT, spectrum AM 1.6 0 CELLS PERFORMANCE WARRANTY PERFORMANCE AT LOW IRRADIANCE At least 98% of nominal power during first year. Thereafter max. 0.5% degradation per year. At least 93.5 % of nominal power up to 10 years. At least 86 % of nominal power up to 25 years. All data within measurement toleranc- es. Full warranties in accordance with the warranty terms of the Q CELLS sales organisation of your respective __T__-__- ___________ ____, i i a a ' as ass aea ese see yeas seuAMA,NCE ocl-i :o country. Yva:; Typical module performance tinder low irradiance conditions in " `, 2 1 comparison to STC conditions (25'C,1000 W/m2) TEMPERATURE COEFFICIENTS Temperature Coefficient or Ir,: .� a � [%//K] ��.�• +0.04 Tempe i,ature Coefficient fficien at V;�._.�.-.�. I%/K] � .��..�•...•.0.27�y [% aure Coefficient c Pti y /K] �0.34 Nominal Module Operating T±rnoer�atu e NMOT ['F] � 109±5.4 (43±3'C) PROPERTIES FOR SYSTEM DESIGN 4aximeam System Voltage V_, IV] 1000 (IEC)/1000 (UL) pV module classific;at'ton Class 11 Maximurm Series Fuse Rating � [A DC] � 20 Fire RaVng based on ANSI,, UL 61730 � � TYPE 2� Max. Design, Lorid,Push ;Pull' [Ibs/ft7 75 (3600 Pa) / 55 (2660 Pa) "- PermittedModuleTerperatare �-40'Fupto+185°F l0aa. Test Loan, rormh,,Pull,' � � [I1s/ft2] 113 (5400Pa)/84 (4000Pa) an Continuous ;loos Duty (-40°C up to+$5°C) 'See Installation Manual QUALIFICATIONS AND CERTIFICATES PACKAGING INFORMATION �ILL 61730 CE-compl'anih.r".4'y��,.1V`I � it � 6� Quality Controlled PV-TUV Rheinland. IEC 612152016 IEC 61730-20].6 J1 -»�»-- --- - Us_PatantNe-a.asa,zistsolarcens},® ( x�uenemmna Nortzrfa( 76.41n 43.3in 48.Oin 16561bs 24 24 32 o C 1111-LI �e packaging 1940mm 1100mm 1220mm 751kg pallets pallets modules vE syse mii+riziazi_ �_ Note; Installation instructions must be followed_ See the installation and operating manual or contact our technical service department for further information on approved installation and use of this product. Nanwha Q CELLS America Inc. 400 Spectrum Center Drive, Suite 1400, Irvine, CA 92618, USA I'TEL +1949 748 59 96 1 EMAIL inquiryQus.q-celisoom I WEB www.q-ceiis.us �*wer eftiex-tly. T*;4,r!?,ix 4f tke sexcic**4juct_*r-�vseV -aicrolliverter is our proprietary application -specific integrated circuit (ASIC) which enables the 55nm technology with high speed digital logic and has super -fast response times t* chariginti 1#&4s an4 grili ayants, &111;sylating e*iistraints iiin *att6ry sizing. f*r N*ma energy systems. Part of the Enphase Energy System, 108 Series 108 Series Microinverters redefine reliability Microinverters integrate with the Enphase IQ Battery, standards with more than one million cumulative Enphase 10 Gateway, and the Enphase App monitoring hours of power -on testing, enabling an industry - and analysis software. leading limited warranty of up to 25 years. Connect PV modules quickly and easily to 108 Series 108 Series Microinverters are UL Listed as Microinverters using the included Q-DCC-2 adapter PV Rapid Shut Down Equipment and conform with cable with plug-n-play MC4 connectors. various regulations, when installed according to manufacturer's instructions. 0 2022 Enphase Energy, All rights reserved. Enphase, the Enphase logo, 108 Microinverters, and other names are trademarks of Enphase Energy, Inc. Data subject to change. INOMN - �06 rat Easy to Install t plug-n-o* connectors Power Line�Comrftuhhitotlbiin bom (Ott) etween cmponents it Faster installation with simple two -wire cabling - Complies with the latest advaliced grid Wipport" &_VATt,gm�A� range of grid profiles - Meets CA We 21 (UL 1V_$A) requirements Commonly used module pairingsz w 235 - 350 Module compatibility 60-cell/120 half -cell MPPT voltage range v 27 - 37 Operating range V 25 - 48 Min/max start voltage V 30 / 48 Max input DC voltage v 50 Max DC currents [module Ise] A Overvoltage class DC port DO port backfeed current mA PV array configuration Peak output power VA Max continuous output power VA Nominal (L-L) voltage/range` v Max continuous output current A Nominal frequency Ha Extended frequency range Hz AC short circuit fault current over 3 cycles Arms, Max units per 20 A (L-L) branch circuits Total harmonic distortion Overvoltage class AC port AC port backfeed current mA Power factor setting Grid -tied power factor (adjustable) Peak efficiency % CEC weightedefficiency % Night-time power consumption mw Ambient temperature range Relative humidity range DO Connector type Dimensions (HxWxD) Weight Cooling Approved for wet locations Pollution degree Enclosure Environ. category / UV exposure rating 235 - 440 260 - 460 295 - 500 320 - 540+ 295 - 500+ 60-cell/120 half -cell, 66-cell/132 half -cell and 72-celi/144 haif-cell 29 - 45 33 - 45 36 - 45 38 - 45 38 - 45 25 - 58 30 / 58 60 I. 108-60-2-US IOSPLUS-72.2-US I9814-72-24S I08A-72-24S108H-20-7244S 108H-268-72-24S 245 ## 330 # 290 325 349 380# # #° # 1.0 In W. 2 13 11 11 10 <5% III 30 1.0 0.85 leading - 0.85lagging 97.6 97.6 97.6 97 97 97.5 60 -400C to +600C (-4011F to +1400E) 4% to 100% (condensing) MC4 212 mm (8.3") x 175 mm (6.9") x 30.2 mm (1.2") 1.08 kg (2.38-Iles) Natural convection - no fans Yes PD3 Class It double -insulated, corrosion resistant polymeric enclosure NEMA Type 6 / outdoor CA Rule 21(UL 1741-SA), UL 62109-1, UL1741/IEEE1547, FCC Part 15 Class 8, ICES-0003 Class 8, CAN/CSA-C22.2 NO.1079-01 Certifications This product Is UL Listed as PV Rapid Shut Down Equipment and conforms with NEC 2014, NEC 2017, and NEC 2020 section 690.12 and C22.1-2018 Rule 64-218 Rapid Shutdown of PV Systems, for AC and DC oonduotors, when Installed according to manufacturer's instructions. (1) The IO8H-208 variant will be operating in grid -tied mode only at 208V AC. (2) No enforced DC/AC ratio. see the compatibility calculator at https://Iink.enphase.com/module-compatibility (3) Maximum continuous Input DO current Is 10,6A (4) Nominal voltage range can be extended beyond nominal if required by the utility. (5) Limits may vary. Refer to local requirements to define the number of microinverters per branch in your area. 108SE-DS-0001-01-EN-US-2022-03-17 4Less Aluminum )fAdditional MountingOptions 4Metal, EPDM, Orl TPOI & Asphalt Roofs 1 suitable systemst t. 7Y C.arriage Bolt EMT RT Serrated " R RT-Butyl is RPofTeoh«m flexible flashing used in one mU|inn residential PVsystems for the last 27years, &is the first PVmnundng system with Flexible Flashing certified by the |CC, Engineered to withstand wind speeds Lip bo10)mph and ground snow upto90pmt Dimensions in (mm) Offset Rafter Attachment O,��� SPAN 'L' (BETWEEN fl II II II ii I! it fl ii II ti I! it ft I{ i tl fi GI Ii iI II 4! 11 I II it Rt 1i tt t: ti tT I II II 6i II it ii II II A II A II ti4 yl i� II it It It s t ! RI I fl i t - --__ _ -_ -i Ut _-- �i __-JL.-LI__ ii f! If TI t! EI !I It If tl kt !! It 11 ii I( IE .�y._--•--Vi.�- _ _____ n. €i ! i! !1 111 FI II II iT fl i• It . IV All, ii 1 ti it 1( IV tf Ii it J _.-__J.1i_-u. _ __ _ _ Jii_ __.1J__{�{({'_ Ti ! •SIT `tt � t11 � C! � ^"II jl iSIWI. II F 4f it 11( ii It II II ii I ! if HI IV ti it f' _ _ _ _�.0 v _ - 1L _ u t u nt a II i t t F I I 141 I V q I I I I i i ROOF TRUSSES NOTE: OVERHANG AS PER PANELMANUFACTURER'S INSTRUCTIONS. SHOULD BE EQUAL ON BOTH SIDES OF PANELS. DESIGN LOAD CAPA - PRY ( CAPE MODULES) UP TO 80' PANEL LENGTHIS NUMBER SPAR! OF RAILS `L' FLAT ROOFS ROOF SLOPES UP TO 7® ROOF SLOPES 0' TO 2(r ROOF SLOPES 21• TO 29" ROOF SLOPES Zr TO 45' ANCHOR ANCHOR TYPE 'A` TYPE 'S' ANCHOR TYPE 'A' TYPE •®• MOM TYPE •A•.TrPE '8' ANCHOR TYPE 'A' AN04OR TYPE '8' ANCHOR TYPE 'A' MOM TYPE '8' 16, 230.3 247.8 229.6 247.2 228.2 245.8 227.3 1 245.0 225.2 243.0 24, 154.9 166.6 154.2 165.9 152.7 164.5 851.9 163.8 749.7 161.7 32- 117.2 125.911, 190.5 t25.3 115.0 1123.9 1t4.2 123A 112.0 121.1 2 1. 79.4 85.3 78.7 84.6 77.3 83.3 16.5 82.5 74.3 80.4 64' 60.6 65.0 59.9 64.3 58.4 62.9 57.6 62.2 55.4 60.1 72" 54.3 58.2 53.6 57.5 52.1 56.2 51.3 55.4 49.1 53.3 16- 250.0 250.0 250.0 250:0 2504 250.0 250.0 250.0 250.0 250.0 24" 20S.4 225.2 208.E 224.5 207.1 223A 206.3 222.4 204.1 220.3 32' 158L 169.9 157.3 169.2 I55.8 167.9 155.0 167.1 152.8 165.E 3 48' 106.6 114.6 105.9 113.9 104.5 112.6 $03.7 111.8 101.5 109.7 64, 51.0 86.9 80.3 86Z 78A SCS 78.0 84A 75.8 82.1 72" 72.4 L17.7 7t.7 77.1 70.3 75.7 j 9.4 74.9 67Z 72.9 LOADS SHOWN IN CHARTS ABOVE ARE FOR PANEL WIDTHS UP TO 400 FOR WIDER PANEL WIDTHS (41" TO 48-), DETERMINE DMON LOADS AS FOLLOWS DESIGN LOAD m LOAD FROM CHART X 40 NEW PANEL WIDTH Lf �`y q R V Z Ai }.Q�W, 4. W d ,yM� PV RAILS Q t I A 2 OR 3 PER PANEL pQ a et EQUALLY SPACED or C tC m 8 SEE CHART BELOW 0 p o qQ A oat �z� m 12 RT-MINI II ROOF TOP PV MOUNTING SYSTEM CD THIS PRODUCT HAS BEEN DESIGNED AND TESTED TO COMPLY WITH THE Z O REQUIREMENTS OF THE 2020 (7TH EDITION) FLORIDA BUILDING CODE z 04 INCLUDING HIGH VELOCITY HURRICANE ZONE (HVHZ). CT ar THIS PRODUCT APPROVAL IS FOR THE ROOF TOP PV MOUNTING SYSTEM AS SHOWN ON THESE APPROVED DRAWINGS. its ROOF DETAILS, UPLIFT. SLOPE, ROOF TRUSSES AND OTHER ELEMENTS SHALL BE DESIGNED BY A FLORIDA REGISTERED ENGINEER AND REVIEWED 0_ CD s- V. E ,,, w 0, BY THE STRUCTURAL S EXAMINER OF THE CORRESPONDING E tjt BUILDING DEPARTMENT, CONDITIONS NOT SHOWN IN THIS DRAWING ARE TO BE ANALYZED SEPARATELY, p c c u AND TO BE REVIEWED BY BUILDING OFFICIAL 0 _ INSTALLATION OF PV PANEL ACCESSORIES SHALL BE PONE IN ACCORDANCE WITH THE CURRENT EDITION OF FLORIDA BUILDING CODE AND THE ? as m - o 6 " MANUFACTURER'S INSTALLATION INSTRUCTIONS. M O m ANCHORS SHALL BE CORROSION RESISTANT, SPACED AS SHOWN ON DETAILS 0C AND INSTALLED PER MANUF'S INSTRUCTIONS. SPECIFIED EMBEDMENT TO BASE MATERIAL SHALL BE BEYOND ROOF COVERING. DESIGN LOADS SHOWN ARE BASED ON 'ALLOWABLE STRESS DESIGN (ASD)'.SOLARAPANELS ml� TO ALLED P L TO THE ROOF SURFACE WITH A 11 2 DBEINS PV PANELS NOT PART OF THIS APPROVAL. FOR PANEL DETAILS, GENERAL NOTES. COMPONENT SIZES, PANEL RAIL CONNECTION TO RT-MINI 11 AND INSTALLATION REQUIREMENTS/LIMITATIONS SEE CORRESPONDING FL.A, APPROVAL DWGS. A- CONTRACTOR TO BE RESPONSIBLE FOR THE SELECTION, PURCHASE AND RMALLABON OF THIS PRODUCT BASED ON THIS PRODUCT EVALUATION PROWDED HE/SHE DOES NOT DEVIATE FROM THE CONDITIONS DETAAED ON THIS DOCUMENT. 0-THIS PRODUCT EVALUATION DOCUMENT WILL BE CONSIDERED INVAUO IF ALTERED BY ANY MEANS. C- SITE SPODFTC PROJECTS SHALL BE PREPARED BY A FLORIDA REGISTERED Yf}PK,"N WILL KOOME THE EN13NER OF RECOITO (EOR) FOR THE PROJECT AND WHO WILL BE RESPONSIBLE FOR THE PROPER USE OF hkE P.E.D. ENGINEER OF RECORD. ACTING AS A DELEGATED U4WEER TO THE P.E.D. ENGINEER STALL SUBMIT TO THIS LATTER THE SITE SPECIFIC ORMWMGS FOR REVIi£5#. D- THIS P£1}. SHAU. BEAR THE DATE AND CRONIN. SEAL AND SIGNATURE OF THE PROFESSKNIAL ENGINEER OF RECORD THAT PREPARED IT. ONi l J n Na, 0=3 o _ 0T •��j4 drawing no. 21--27F SPAN 'L: (BETWEEN ----------- L --------- 11 It II it --- --- L --------- it J, A A ::i t I I T-1 it I 4' It II liil 11 Et If It It L it ti. It it it ROOF TRUSSES L TT It It A DESIGN LOAD CAPACITY - PSF (PORTRAIT MODUM) UP TO W PANEL LENGTHS NUMBER OF RAILS SPAN V FIAT ROOFS ROOF SLOPES UP TO 7* ROOF SLOPES 8' TO 20* ROOF SLOPES ROOF SLOPES 21' TO 27' 28' TO 46' a =H�J�r ANCHOR TYPE 'K NXHOR TYPE 'IT VICHOR ANCHOR ANOM TYPE 'A" TYPE 'Er TYPE 'A! MOM TYPE V 16- t37.1 147.4 136.4 146.8 t32.0 142-6 24" 92,8 99.6 92.0 99.0 67.6 94.8 32- 70.6 75.7 6919 75.1 65.4 70.9 2 W 48.4 51.8 47.7 51A 46.2 4918 45.4 49,0 43.2 47.0 1. 37.3 39.9 36,6 39.2 35.1 37A 34.3 37.1 32.1 35.0 72- 33.6 35.9 M 35.2 31.4 55's 3016 33.1 2&4 31.0 16, 175Z MJ 174AI 188.1 173-3 18&7 172Z 185.9 t7O.3 183.9 - 2 118.3 127.2 11 7_�6 r 1 126.5 116.1 125.1 115Z 124.3 113.2 122.3 12' 89.7 96.4 8910 95J 87.6 94,3 86.7 93,6 84.6 91.5 61.2 65.6 WA 64A 59.0 616 58.2 62.8 56,0 60.7 _48; 64" 4&9 50.2 46,2 49,5 44,7 48,2 43.9 47.4_ 41.7 45.3 72* +2.1 45.1 41.4 "A 1 39,9 1 mo in. I 142.2 Lzi.B 402 LOADS SHOWN IN CHARTS ABOVE ARE FOR PANEL LENGTHS UP TO W FOR SHORTER PANEL UFNMGS, DETERMINE DESIGN LOADS AS FOLLOWS LOAD FROM CHART X 68 DESIGN LOAD = NEW PANEL LENGTH NOTE: OVERHANG AS PER PANEL MANUFACTURER'S INSTRUCTIONS, ei SHOULD BE EQUAL ON BOTH SIDES OF PANELS. ; -a t 0 PV PALS a 2 OR 3 PER PAN0 ra -EQUALLY SPACED EL SEE CHART BELOW DESIGN LOAD CAPACITY - PST (PORTRArf MODULES) UP TO W PANEL LENGTHS NUMBER SPAN OF PALS L: FIAT ROOFS ROOF SLOM UP TO 7' RODS SLOPES r TO ar ROOF SLOPES ROOF SLOPES 21* TO 27' 28' TO 45` ANCHOR TYPE 'A'jTYPE *"8' ANCHOR ANCHOR TYPE 'A' TYPE *S` 94CHOR TYPE 'K ANCHOR TYPE 'S' ANCHOR MOM ANCHOR ANCHOR TYPE 'A` TYPE 'S' TYPE "A! TYPE '0' i6" 1172 125.9 116.5 125.3 115.0 123.9 114.2 123.1 112.0 121.1 24'- 79,4 853 78.7 �6 "_S 77-3 833 76.5 82.5 74.3 80.4 1. 60'6 60,6 654 F1253 59A 64.3 58.4 62,9 57.6 62.2 55.4 601 "76 41.7 44.6 41.0 ".0 34w6 42.6 3&7 41.8 36-6 39.8 64* 34,5 314 33.8 30.1 324 29.3 31.7 27.1 29.6 72' 29.1 31.1 2&4 30.4 27.0 29.1 26.2 2&3 24.0 261 16' F47, 13411 1".1 133.4 143.6 131.9 142.1 131.1 141,3 128.9 1392 24* 90.7 97.4 Bob 9618 88,6 95.4 87J 94.6 85.6 SZ6 32' 69.0 74.1 !""4 683 73. 66,9 72-1i 66.0 69.2 T-3 -ii- _71.3 -9 1. 47.4 50.7 W - 6 5D, :4=5.2 4L,7 42.2 44.4 47-9 45,9 64* 3615 39.0 35.8 38.4 34.4 374 33.5 36.2 31 A 341 72' 32,9 35,11 3Z2 30.7 nI 1 29,5 32.3 _17,8 30,3 LOADS SHOWN IN CHARTS ABOVE ARE FOR PANEL LENGTHS UP TO 80' FOR SHORTER PANEL LENGHTS 68 TO 80 1 DETERMINE DESIGN LOADS AS FOLLOWS z z 0 C-4 M < 0 0 CNI 010 c En N IM223 o' drowing t W� 2 -27F EQ. 'X 3/16-± (3OMM)_/' (140 BOLT ZONE) _j L 1, M' 2 - .' EQ. EQ. RAIL CENTERLINE t RAIL CENTERUNE ALLOWABLE ZONE I ALLOWABLE ZONE ---- MIDDLE 2.V' t MIDDLE 2.5" 0 0 3/8 3/8. 3.937 2.756 0 0 3/16"± (30MM) 1 3/16-± (30MM) 1 3/16-± (30MM) (NO BOLT ZONE) (NO BOLT ZONE) "'N (NO BOLT ZONE) ,_I 9/16"± (40MM) 1 9/1 6-± (.M)/-2" MIN. 323 (ALLOWABLE BOLT ZONE) (ALLOWABLE BOLT ZONE) r 1 .063 .614 T090 i PV MODULE NOT PART OF T1415 APPROVAL ----------------------------- PV MODULE RAIL NOT PART OF THIS APPROVAL 5/16- DW BOLT - ----------- F- IN A 19 L-FOOT OR EMC NOT PART OF THIS APPROVAL PLYWOOD SHEATHING F "5/32' MAX. FOR FASTENER TYPE 9/32' MAX FOR FASTENER TYPE RT-MINI H FASTENER$ (2) PER BRACKET I By ET -�E- SEnIQN A- RT—MINJ 11 FASTENERS: (AT ROOF TRUSSES) rfpE A oarom SS304 SELF—ORILLING SCREWS (MAX. ALLOW. TENSION = 569 lbf. MAX. ALLOW. SHEAR - 404 lbf) TYPE 'Er- MS X 90mm $S304 SELF —DRUM SCREWS (MAX, ALLOW. TENSION = 613 W, MAX. ALLOW. SMEAR - 470 lbf) CENTERED AT WOOD TRUSSES (SG - 0.50 MIN,) EE—M#* W3-T5 Npff'w� rx Z otio 0 5, am 04 t W z Z M j z g a 0 a, 0 C'4 0 a o c c x 0 0 �. a w- CV 0 ji ol c )/2021 O ft 91223 0 xSTdr21awing no. —27F RAIL STRONGHOLD ATTACHPIENT KIT SEE PAGE NH-P01 SEE PAGE NH-A04 gxoj#?2222 d; ^ \\ y \. \ DESCRIPTION: -110#01114AVAMml PRODUCT PROTECTED 8 , K 1� PHONE: 505.242.6411\j./\\. . \#2§�f^\`<£w WWW.UNIRAC.COM 11 \ f m ]2 e,. a ±:: 9/30/2021 LEGAL NOTICE 61;144 WIRE Ml(3MT CUP RAIL & CLAMP b'. 4P. KIT SEE ► a a a.. SEE •. ale PRODUCT II II ICI I IHORIZON Vu ZM NOT TO SCALE ALL III ul Igll�l DIMENSIONSdrUNIRAC, III sil . YPART & ASSEM13LY NOMINAL 1411 « BROADWAY NE II IIM IM pull III 1 IUIII @ ill �I�IIIII� p III UI II I III PHONE: +` IA I Ire a WWW.UNIR Will � ! '�,I�` i E' " 1 ! 'LEGAL'!' PART # TABLE DESCRIPTION NXT HORIZON COMBO CLAMP - MILL NXT HORIZON COMBO CLAMP - DARK lV411 30MM TO 40MM MODULE FRAME is I= lw�A 11 sh I Zlone DE-S-C-RIPTION: COMBO CLAMP PRODUCT PROTECTED BY PHONE: 505.22,6411 WWW.uNW4.cOm 0 �ko 9/30/2021 LEGAL NOTICE NAM PART ! . TABLE DESCRIPTION STRONGHOLD ATT KIT COMP MILL 7 ! ! HOLD ATT KIT ! ! �} �S�fRONGiiOLD ATT ! MILL (NS) ! STRONGHOLD ATT COMP , ! as • ► a 6' x aLAG BOLT ' e• R d %ev PRODUCT LINE; N HORIZON gas gage U N I RAC INTGTG TYPE: PARTS ASSEMBLY R 1 } i !I'M! III III IIIII 1 I ! i d 14 1a d = LEGAL NOTICE PART # . < TABLE .....yDESCRIPTION ....\ .a: ©?f$»? OLD R » CLAMP MILL CMf\\\.\\\\\\\\.f\ RAILCLAMP DRK on . .\*`: an maw » t!■> 2 - ?# < i;4d'#2 d CE<a PHONE: 422221. d. 22'd ? t° \� \ \ -?1.Ax/ : SERRATED FLANGE HEX SCREW ff##2y\<y:2: 2222#f}2#2 »j¥«: «<+c. f\2\\* 2 #�lum7ffml \#22d< HOMa \§ f 2 ya; NOTICE NMI PART # TABLE DESCRIPTION N HORIZON MLPE & LUG CLAMP a ""UNIRAC n an PHONE: 505.242.6411 WWW.UNIRAC.COM C/lr-11-10 - ill va7sl#22L\\d\ Fl IT; R �.*, 1, �* k M 7-FEWPUTANM U-1,01,1110, "I's -11211 (ii.qLarli'vo2f,fV-#Pl�,tT-�,�"XIII'tI LEGAL NOTICE PART # TABLE DESCRIPTION WN UIRACon Nas PHONE: 505.242.6411 WWW.UNIRAC.COM I m N. N A# » 2 § \ 2} � I I, Kid [ am [Q Z Wk*l 011 fly URTLHRMTWAI!/2/\«21 DRAWING NOT TO SCALE ALL DIMENSIONS ARE NOMINAL AN ww l 11 LEGAL NOTICE PART # BLE DESCTIRIPON M&MUMORM NXT HORIZON WIRE MGMT CLIP i ""UNR IAC ts as PHONE: 505.2416411 WWW.UNMK.COM PRODUCT LINE: NXT HORIZON II I folom-l-wo MW WIRE MGMT CLIP m im LEGAL NCfflCE KM o ""UNIRAC n as swummill"ll MiAl"alliti-MM Ulwymits 1 PHONE: 505.242.6411 dyemda© PART # TABLE DESCRIPTION M, 70ATEVET'diEwn 7-MMUMMIMEM im M-11,11410"T"110611,14 [#j;,Lx#g4j, ,,41#Rt Mjgj pgI LEGAL NOTICE 0 ow Rmi PART # TABLE DESCRIPTION NXT HORIZON RAIL 84" MILL NXT HORIZON RAIL 84" DARK N HORIZON RAIL 168" MILL NXT HORIZON RAIL 168" DARK NXT HORIZON RAIL 208" MILL NXT HORIZON RAIL 208" DARK NXT HORIZON RAIL 246" MILL NXT HORIZON RAIL 246" DARK I o ""UNIRAC n an PHONE: 505.242.6411 ®d F&T.R.MMUNNIUM I bj;&*io "A 1:9 1 roff U-70TOWATlym4. Te m LEGAL NOTICE NUM IF- PART # TABLE \\\\\ \\ /\ \\ ' RIPTION Es \\\\\. IL N RAc Ji6� SPLICE NXT HORIZO \\ \\\\\ if "OUNIRAC man alm * 0 A 101*14 9 CARLO 00-10 V ATT= W 11 W �411 �ft- - �, om fit I -11�m Da1a Shee,' Enphase Networking IQ Combiner 44C X2-IQ-AM1-240-4 (IEEE 1547:2018) (9 USTED To learn more about Enphase offerings, visit gnpbaAex_m IQ-C-4-4C-DS-01 03-EN-US-1 2-29-2022 The IQ Combiner 4/4C with IQ Gateway and integrated ATE-Ml cell modem (included only with IQ Combiner 4C) consolidates interconnection equipment into a single enclosure. It streamlines IQ Microinverters and storage installations by providing a consistent, pre -wired solution for residential applications. It offers up to four 2-pole input circuits and Eaton BR series bulbar assembly. Includes IQ Gateway for communication and control Includes Mobile Connect cellular modem (CELLMODEM-M1-06-SP-05), included only with IQ Combiner 4C Includes solar shield to match Enphase IQ Battery aesthetics and deflect heat Supports Wi-Fi, Ethernet, or cellular connectivity Optional AC receptacle available for PLC bridge Provides production metering and consumption monitoring Em Mounts on single stud with centered brackets Supports bottom, back and side conduit entry Allows up to four 2-pole branch circuits for 240VAC plug-in breakers (not included) 80A total PV or storage branch circuits Durable NRTL-certified NEMA type 3R enclosure Five-year limited warranty Two years labor reimbursement program coverage included for both the IQ Combiner SKU's UL listed X2-IQ-AM1-240-4 and X2-IQ-AM1-240-4C comply with IEEE 1547:2018 (UL 1741-SB, V Ed.) IQ Combiner 4/4C MODEL NUMBER IQ Combiner 4C IQ Combiner 4C with IQ Gateway printed circuit board for integrated revenue grade PV production metering (ANSI C12,20 t 0.5%) X-IQ-AM1-240-4C and consumption monitoring (± 2,5%). Includes Mobile Connect cellular modem (CELLMODEM-M1-06-SP-05), a plug -and -play X2-IQ-AM1-240-4C (IEEE 1547:2018) industrial -grade cell modem for systems up to 60 microinverters. (Available in the US, Canada, Mexico, Puerto Rico, and the US Virgin Islands, where there is adequate cellular service in the installation area.) Includes a silver solar shield to match the IQ Battery and IQ System Controller and to deflect heat. ACCESSORIES AND REPLACEMENT PARTS (not included, order separately) Supported microinverters 106,107, and 108. (Do not mix IQ6/7 Microinverters; with IQS) Communications Kit COMMS-CELLMODEM-Ml-06 - Includes COMMS-KIT-01 and CELLMODEM-M1-06-SP-05 with 5-year Sprint data plan CELLMODEM-M1-06-SP-05 4G based LTE-Ml cellular modem with 5-year Sprint data plan CELLMODEM-M1-06-AT-05 4G based LTE-Ml cellular modem with 5-year AT&T data plan XA-SOLARSHIELD-ES Replacement solar shield for IQ Combiner 4/4C XA-PLUG•120-3 Accessory receptacle for Power Line Carrier in to Combiner 4/40 (required for EPLC-01) X-IQ-NA-HD-125A Hold-down kit for Eaton circuit breaker with screws ELECTRICAL SPECIFICATIONS Rating Continuous duty System voltage 120/240VAC, 60 Hz Eaton DR series bulbar rating 125A Max. continuous current rating 65A Max, continuous current rating (input from PV/storage) 64A Max, fuse/circuit rating (output) 90A Branch circuits (solar and/or storage) Up to four 2-pole Eaton BR series Distributed Generation (OG) breakers only (not Included) Max. total branch circuit breaker rating (input) 80A of distributed generation/95A with IQ Gateway breaker included IQ Gateway breaker 10A or 15A rating GE/Slemens/Eaton included Production metering CT 200A solid core pre -installed and wired to IQ Gateway MECHANICAL DATA Dimerisiona, (WxHxD) 37.5 crin x 49.5 cm x 16.8 am (14.75 in x 19.5 in x 6.63 in), Height Is 53.5 cm (21.06 in) with mounting brackets, Weight 7.5 kg (16.5 lbs) Ambient temperature range -401C to +460C HOOF to 1 150F) Cooling Natural convection, plus heat shield Enclosure environmental rating Outdoor, NRTL-certified, NEMA type 3R, polycarbonate construction Wire sizes 20A to 50A breaker inputs. 14 to 4 AWG copper conductors 60A breaker branch input: 4 to 1/0 AWG copper conductors Main lug combined output: 10 to 2/0 AWG copper conductors Neutral and ground: 14 to 1/0 copper conductors Always follow local code requirements for conductor sizing, Altitude Up to 3,000 Meters (9,842 feet) INTERNET CONNECTION OPTIONS Integrated WI-F! IEEE 802.11b/g/n Cellular CELLMODEM-M1-06-SP-05, CELLMODEM-M1-06-AT-05 (4G based LTE-MI cellular modem). Note that an Mobile Connect cellular modem is required for all Enphase Energy System installations. Ethernet Optional, IEEE 8023, Cat55 (or Cat6) UTP Ethernet cable (not Included) COMPLIANCE Compliance, IQ Gateway UL 60601-1/CANCSA 22.2 No. 61010-1 @ 2022 Enphase Energy, All rights reserved. Enphase, the Enphase logo, IQ Combiner 4/4C, and other names are trademarks of Enphase Energy, Inc. Data subject to change. 1Q-C-4-4C-DS-01 03-EN-US-12-29-2022 SYSTEM INFORMATION MODULE HANWHA Q.PEAK DUO BLK ML-G10+ 405 INVERTER ENPHASE IQ8PLUS-72-2-US RACKING ROOFTECH RT-MINI II W/ UNIRAC NXT HORIZON 2-RAIL RACKING SYSTEM SYSTEM SIZE (DC) 11,745 KW LOCATION 28.2547749,-82.2229064 THIS PV SYSTEM HAS BEEN DESIGNED TO MEET THE MINIMUM DESIGN STANDARDS FOR BUILDING AND OTHER STRUCTURESOF t • 7TH EDITIONi _LORIDA RESIDENTIAL CODE,EDITION : # FLORIDA BUILDING # EDITION• FLORIDA FIRE PREVENTION CODE, NEC 2017 AND ALL LOCAL *RDINANCES. ROOF SHALL HAVE NO MORE THAN TWO LAYERS OF COVERING IN ADDITION TO THE SOLAR EQUIPMENT. ANY PLUMBING VENTS ARE NOT TO BE CUT OR COVERED FOR SOLAR EQUIPMENT INSTALLATION, ANY RELOCATION OR MODIFICATION OF THE VENT REQUIRES A PLUMBING PERMIT AND SYSTEM UTILIZES aSE" MICRO -INVERTERS WITH RAPID SHUTDOWN CONTROL LOCATED ON THE BACK SIDE OF EACHMODULE. U1,141144 ► t . t.. 1111 Lill III Ill I CLIMATIC & GEOGRAPHIC DESIGN CRITERIA TABLE R301.2(1) SPEED (MPH) 140 TOPOGRAPHIC EFFECTS B SPECIAL WIND REGION NO WIND BORNE DEBRIS ZONE 2 SEISMIC DESIGN CATEGORY C CLIMATE ZONE 2A WIND EXPOSURE CATETORY B FIBC, RESIDENTIAL 2020 TABLE R301.2,1.3 } 3 WIND SPEED CONVERSIONS2 I j`J,'110115120130140'150i160j170;180 1902 sc1lj, 85 11 89 j 90 II ' 01 1081116 j 124132139 � 14 7 1551 For SI: 1 mile per hourJ0.447 M_/S. a. Linear interpolation is permitted. I HANWHA Q.PEAK DUO BLK ML-G10+ 405 405 *MODULE t • r a PLAN KEY PV-1 COVER PAGE PV-1.1 ATTACHMENT DETAIL PV-1.1(2) ATTACHMENT DETAIL PV-1.2 INVERTER SPECS PV-1.3 COMBINER SPECS PV-1.4 PANEL SPECS PV-2 PANEL LAYOUT PV-3 ELECTRICAL PV-3.1 ELECTRICAL CONT. PV-3.2 EQUIPMENT LABELS BILL OF MATERIALS MODULES 29 INVERTERS 29 L-FOOT ATTACHMENT W/ RT-MINI 70 171" RAILS 13 SKIRTS 0 ENPHASE COMBINER BOX 1 EATON 60A FUSIBLE AC DISCONNECT 1 50A FUSES 2 125A LINE TAPS 2 SOLAR PRO CUSTOM SOLAR LLC D.B.A. MOMENTUM SOLAR 325 HIGH STREET, METUCHEN, NJ 08840 (732) 902-6224 MOMENTUMSOLAR.COM PROFESSIONAL ENGINEERING CAMERON CHRISTENSEN CERTIFSED SOLAR CONTRACTOR LICENSE NUMBER', CVC57136 MOMENTUM SOLAR 5728 MAJOR BLVD. SUITE 307, ORLANDO FL. 32819 MIGDALIA GRANDE - MS139356 6806 WAGON TRAIL STREET ZEPHYRHILLS, FL 33541 6466103285 SYSTEM SIZE (DC): 11.745 KW 29 MODULES: HANWHA Q.PEAK DUO BLK ML-G10+ 405 29 INVERTERS: ENPHASE IQ8PLUS-72-2-US PROJECT INFORMfATION INITIAL _ DATE: 10/19/2023 DESIGNER: AM REV: DATE: DESIGNER: REV: DATE: DESIGNER: COVER PAS is PART # TABLE P/N DESCRIPTION LENGTH NXT HORIZON RAIL 84" MILL NXT HORIZON RAIL 84" DARK NXT HORIZON RAIL 168" MILL NXT HORIZON RAIL 168" DARK NXT HORIZON RAIL 208" MILL 208" NXT HORIZON RAIL 208" DARK NXT HORIZON RAIL 246" MILL NXT HORIZON RAIL 246" DARK 1% V/4 LENGTH RAIL DRAWING NOT TO SCALE ALL DIMENSIONS ARE NOMINAL - ----- ---- - - -- PRODUCT PROTECTED BY . PRODUCT LINE: NXT HORIZON — - -------- ------------------- -- - - - DRAWING TYPE:'; PART DETAIL DESCRIPTION: REVISION DATE: 9/13/2021 LEGAL NOTICE I [ SHEET ) PART # TABLE P/N DESCRIPTION LENGTH RLSPLCM1 NXT HORIZON RAIL SPLICE 10" 4X - 5/16"-18 x 5/8" HEX FLANGE SCREW F DESCRIPTION: RAIL SPLICE REVISION DATE� 9/22/2021 -TYPE 1/16 1/2 DRAWING NOT TO SCALE ALL DIMENSIONS ARE NOMINAL PRO CUSTOM SOLAR LLC D.B.A. MOMENTUM SOLAR 325 HIGH STREET, METUCHEN, N3 08840 (732) 902-6224 MOMENTUM501-AR.COM PROFESSIONAL ENGINEERING I PR03ECT INFORMATION I DATE: 10/19/2023 1 DESIGNER: AM momentum S&LAR,- YOF //i4l0NAL '1�k /iffmlllkl-� CAMERON CHRISTENSEN llRlIFIl. CONTRACTOR LICENSE NUMBER: CVC57036 OMENTU SOLAR I 728 MAJOR BLVD. SUITE 307, ORLANDO FL. 32819 SOLAR MOMENTUM 5 MIGDALIA GRANDE - MS139356 6806 WAGON TRAIL STREET ZEPHYRHILLS, FL 33541 6466103285 SYSTEM SIZE (DC): 11.745 KW 29 MODULES: HANWHA Q.PEAK DUO BLK ML-GlQ+ 405 29 INVERTERS: ENPHASE IQ8PLUS-72-2-US as w ease U N I RlAr 1411 BROADWAY BLVD. NE ALBUQUERQUE, NM 87102 USA PHONE: 505.242 ' 6411 WWW.UNIRACCOM INITIAL REV DATE: DESIGNER: REV: DATE: DESIGNER: : momentum S&LAR,- YOF //i4l0NAL '1�k /iffmlllkl-� CAMERON CHRISTENSEN llRlIFIl. CONTRACTOR LICENSE NUMBER: CVC57036 OMENTU SOLAR I 728 MAJOR BLVD. SUITE 307, ORLANDO FL. 32819 SOLAR MOMENTUM 5 MIGDALIA GRANDE - MS139356 6806 WAGON TRAIL STREET ZEPHYRHILLS, FL 33541 6466103285 SYSTEM SIZE (DC): 11.745 KW 29 MODULES: HANWHA Q.PEAK DUO BLK ML-GlQ+ 405 29 INVERTERS: ENPHASE IQ8PLUS-72-2-US as w ease U N I RlAr 1411 BROADWAY BLVD. NE ALBUQUERQUE, NM 87102 USA PHONE: 505.242 ' 6411 WWW.UNIRACCOM INITIAL REV DATE: DESIGNER: REV: DATE: DESIGNER: : _7 F F EQ, J EQ EQ, Ec' Ci F- RAil CENTEPUNE I I, PAIL 0EN-fERLfNE ZONE A LOWAB E ALLOWABLE ZONE Z MIDDLE 2MIDDLE 0 2�5" z LU CK 1,937 2.756 0 0 L - - - 0 L'U aw;I - — -- - - - - - - - > Uj � < 0 > a < 1 0 t 3/16*'± (,lOMM' 1 �"/16± (30mv, 3plc± ("OvM) 3/16'-± (30MM) x 4 o' I" (NO BOLT ZONE) M; N (NO BOLI ZONE) (NO KILT ZONE MIN, (NO BOLT ZONE) 969 z i h , I Z� 0 1 9/16"± (40MM) - - 2" MIN, 1 9/*6'± (40MV) 2" MIN — I z (ALLOWABLE BOLT ZONE) (ALLCWAB,-E BOLT ZONE; 063 zw 'c'. 106 >_ -- 3,543 — — V" RT-MINI II z z CNI Pv MODU_r 6063-T5 cl NOT -ART OF THIS APPROVAL PV MODULE RAL, tj N07 PART OF THIS APPROVAL ALTERNATE ORIENTATIBOLTc 5/16" DIA HEX BOLT ri L-FOOT OR EMO C c NOT PART OF THIS APPROVAL 4, Ul PLYWOOD SHEATHING 0 < MAX. FOP FASTENER TYA' PE 0 0 o '9/32' MAX. FOR FASTENER TYPE ry BUTYL TAPE VARIES SEE CHART RLASHINO/SPACER T '- ON S�EEIS 1 2 : C_ RT-VINI i \Sl FASTENERS (2) PER BRACKET BY OTHERS 4/20/2021 U SECTION A —A c" RT.-Mink 11 FASTE-NE-PS: (AT ROOF TRUSSES) NO. 84,223 TYPE 'A'- M5 X 60mm SS304 SELF -DRILLING SCREWS (MAX. ALLOW, TENSION = 569 lbf, MAX ALLOW SHEAR = 404 Itf) TYPE 'B'- M5 X 90mm SS304 SELF -DRILLING SCREWS (MAX, ALLOW. TENSION = 613 Ibf, MAX. ALLOW. SHEAR = 470 fDf) S, drowirg no, - CENTERED AT WOOD TRUSSES (S(-! = 0,50 WIN,) 21 -27F Fl, #38617 shee; 3 of 3 momentum SOLAR PRO CUSTOM SOLAR LLC D.B.A. MOMENTUM SOLAR 325 HIGH STREET, METUCHEN, NJ 08840 (732) 902-6224 MOMENTUMSOLAR.COM PROFESSIONAL ENGINEERING CAMERON CHRISTIN51 N CERTIFIED I.IAI CONTRACTOR LICENSE NUMBER CVC57036 MOMENTUM SOLAR 5728 MAJOR BLVD. SUITE 307, ORLANDO FL. 32819 MIGDALIA GRANDE - MS1` 5 T �� 936 S 6806 WAGON TRAIL STREET ZEPHYRHILLS, FL 33541 6466103285 SYSTEM SIZE (DC): 11.745 KW 29 MODULES: HANWHA Q.PEAK DUO BLK ML-GlO+ 405 29 INVERTERS: ENPHASE IQ8PLUS-72-2-US I INITIAL I DATE: 10/19/2023 [DESIGNER: AM I REV: DATE: i DESIGNER: REV: DATE: DESIGNER: a ID 3UUM y momentum c OL A R PRO CUSTOM SOLAR LLC D.B.A. MOMENTUM SOLAR CBENPHASE am= IQ8 and 1Q8+ Microinverters 325 HIGHS METUCHEN , NJ 08840 (732)902-6224 MOMENTUMSOLAR.COM l all: , gall 1! 111 11 IN! !111 111111 '1111 1 11! 1 !11, 1:111 !1!; 1 1 1 MENEEMEM 11! 1 mom= PROFESSIONAL Commonly used modulepfsringn' W 235-350 235-440 ENGINEERING NI c—ral,b,ity 60er/120 lert- op11 60-csfl/120 hall -cell 66-eh/132 halt veil are 72 cell/144 hart-cel V,PPT voltage range a 27 37 29 - 45 Operating range G 25 48 25 58 Not/roax start voltage V 30/48 30 / 58 Mae input DC voltage 50 60 Max DC —on' imodw. I-] A 15 Over —huge class DC Fort DC Pon backfeed cur,ecr qA Cr Re .,,ay exonfigurriterT, 1x1 Ungrounded array ; No addtTamai DC side protection required: AG side protection requires mail, 20A. per branch oincuii Peak, output , power VA 245 300 grax com noorle output power VA 240 290 N.,ni—i (L- Lt voitagefranges V 240/211 264 1�vl 1 11 %X, 3 IQ8 and IQ8+ Microinverters Easy to install Our newest IQ8 Microinverters are the industry's first microgro-forming, software- Lightweight and compact with defined microinverters with split -phase power conversion capability to convert DO plLi connectors power to AC power efficiently. The brain of the semiconductor -based microinverter is our proprietary application -specific integrated circuit (ASIC) which enables the Power Line Communication microinverter to operate in grid -tied or off -grid modes, This chip is built in advanced (PLC) between components sysax contnuous output current, r IC 1.21 No-nai frequency 60 Exlended i,equency!ange Po 5C - 68 AC short circuit fault current - ex icycles A— 2 hicornt,t, per 20 A (L-L) pia-h—cut' 16 13 Total harincotic dield,tdr, 5% V I _ I L, If .. Or 0 PLOR el o "";,,SION At� 55nm technology with high speed digital logic and has super -fast response times Faster installation with simple Overoo!'age class AC Port Ill to changing loads and grid events• alleviating constraints on battery sizing for home two -wire cabling AC port tweef.wd c ...... t mA 30 energy systems. pave: fliur setting Ic High productivity and reliability Sind -tied power factor edipsodde, 0.85 leading - 0.85 aggrur; Produce power even when the ZIN, grid is down* More than one million cumulative hours of testing T Peak efficienry 978 97.6 CEC wo,ghted e ff"'t.'s I, % 97 97 Night-time e.exe, roic—FAwn ns, 60 SOLAR CONTRACTOR CAMERON CHRISTENSEN Class [I double- insulated Part of the Enphase Energy system, 108 Series 108 Seriesenclosure • ferchrunverrers integrate with the Enpriase 10 Battery, standards with mixie than one million cum,,issive Optimized for the latest high- Ambient temperature range -40oCc,,60-C (-40-Ft.,1401F) Relatee humidity range 4,`£to 100'o lo.rds-mg) CERTIFIED SOLAR CONTRACTOR LICENSE NUMBER: CVC57036 MOMENTUM SOLAR 5728 MAJOR BLVD. SUITE 307, ORLANDO FL. 32819 CUSTOMER INFORMATION MIGDALIA GRANDE - MS139356 6806 WAGON TRAIL STREET Eupinase, IQ Gaveyac and the Enphaes Apo monitoring hours of Dower -or. testing, erialolng an industry- and analysis software. leading irl warranty or cis to 25 years. powered PV modules DC Connector type MC4 Dimensions fHsWfD) 212 — is Y) x 175 unn (6.9') x 302 mm 0.2-) Microgrid-forming weight Ic8 kg (2-38 de) ZEPHYRHILLS, FL 33541 Complies with the latest advanced grid support** 60=c Cooling Natural convection -no tans Approved for ewflyes ye 6466103285 PV SYSTEM INFORMATION SYSTEM SIZE (DC): 11.745 KW Remote automatic updates for Poilrifion toogres PD3 29 MODULES: HANWHA Q.PEAK DUO BLK the latest grid requirements Coun—A Try module-, qukly and easily to 108 Series 108 Son- Monsinee,te,,pre UL Listed as Configurable to support a wide rArctor—r—s using the Included Q-DCC 2adavrcr PV Rapid Shut Down Equipment and c—dom—th cable with ping n rli,y MIC4 to,"o.Tco val ous regulations. when installed acoordingto range of grid or offies in En.letsne Cls,ts it denbl-l-cf ni.t., corrosion, resistant forsyscro—relrovire Env an. category UN exposure rating NEMA Type 6)—trioc ML-G10+ 405 29 INVERTERS: ENPHASE IQ8PLUS-72-2-US on—w.t.To'-s instructions Meets CA Rule 21 (UL 1741-SA) CA Pule 21 IUL 1741 W. UL 62109-1. ULI741/IEEE1547. FCC Part 15 Class 6, ICES-0003 Class B. CArril NO, 10TI-01 requirements Certifications This product is CIL Listed as Re Rapid Shnt Circle, Equipment and conforms with NEC 2014, NEC 2017. and NEC 2020 section 69012 are C22,1-2016 Rote 64-216 Rapid shutdown of Re Systems, for AC and DC Panductons.,vner. installed according to 0 2022 EnphasF, Energy, Ail nginsneserved. Enrohase, the Eriona- [.a., iQ8 Micro—e, tee, and turner Only vvio,ri ricaled with IQ Svalern Controller 2, manufacturer's iitxtruetlons,. names are hadernares of Enphese Energy, Inc.. Data subject to change. m-tsIJL 1741. r1i Ric enforced cC/AC ratio. See the swrtseat,bility calculator at PROJECT INFORMATION [08 and 108Plus SLArrcortyf split phase. 240V 08SP-D80002-01-EN-US-2022-O' , 17 iusta.latlons only. Un bee—rin ryy,,,nn,.uasut DC ,,, sully 10.6A (3) Ninmi,nai voltage lengec, bee tended bey o,dnominal f,. required by the GWIty,W Limits may vary. Refer to local requirerrents to define, the number of rdrcroin,octens per branch in You, area. QBSP-DS-0002 -01-EN- JS-2022-03-17 INITIAL DATE: 10/19/2023 DESIGNER: AM REV: DATE: DESIGNER: REV: DATE: DESIGNER: INVERTER SPECS ,e O I. /l, IQ Combiner 4/4C PRO CUSTOM SOLAR LLC D.B.A. MOMENTUM SOLAR MODEL Pi i3 EABER 325 HIGH STREET, METUCHEN, N3 08840 (732) 902-6224 QCombine, 4 4Com!)">ner 4otth is Gateway printed cocue board for sntegrated revenue grade Par prodkction^ e,ersng(ANto Gil 20 +05`%} MOMENTUMSOLAR.COM X- Q-AMI 240-4 and 2 S'r3. it>cludes 3 shwa° s6'ar sngEk3 20 matssi the Yu 9aTY2r5:and EC SysIe,>,, Crn,,.oEier 2 8nd 8o PROFESSIONAL X2- AV1-240-4(IEEE1547.2018I de erth-eat. _ ENGINEERING ACCESSORIES AND REPLACEMENT PARTS Supported micromonters 11)6 Q7 and #Q8 (Do,,ot r,;sx 106. hA,lacanvertare rwr€'° ICSj_ .' .. Ci.c"'It Breakers Sippo.is Eaton 139,210, BR215 BR220. ER230BR240SR250, and BR260 ctrcunbrea' xers BRK-10A 2.240V Cgcwtb€raker, 2 pole: DA Eaton BR210 BRK-15A 2 240V CiTcwl breaker, 2 pole: 15A, Eator, BR215 �ga. Circuit breaker, 2 20A Eator BR226 yak BRKr2DA 2P 246V pole. r breaker AaQon kit `b BRK--75A 2P 24flY B r .t�i 2 pole. 5Fa BR215E w+ti? hold tolwr: support � s' , fr BRX-2CA 2P 24DV B C rrwt breake 2 pole, 20A, Eaton BR2200 iyn i hold down lot support XA PILL 20,3 Ac„esso-yecep,ackifc Ponex Lire Gamerm K) CcrnbirrrI4C(reauseed o?EPLC,O':)a g- - ''_�ffG✓f� -, ' T2aPLtac 2G GLA4P,ConsumptionmCT cur s..eadsfoi-me,s � Tart �yy,«...�- ELECTRICAL. SPECIFICATIONS1 `f � �„ �,� � 444 _, .. _ Lcit 3 E` f( 'l. � a Rating_ — — �..IIfT�"GG�£1i32y _ _.' "'� d't 4(/^.. I'l Q b it ..f q- �`" h�u ._ ... .� `.. �� �" �ax4. • l 3 t✓ ;�-, E"C .CEv ., 4,w T'"•, Eaton 8R sartes busbaf telling 125A �`'" � IQ ;;.�:.e L ,.�4 ,P � J Nq - . In tch IQ'BallE'v ,x x ,u, k s �/ '. ° e' CS.. e( C ,x a,e d r;t c.vrs d ader.eTMt ileal, Max -ccrmmisouscurrent .atengpripur§remPA'storage) 64fi:. 1 t$ C s t ,,.IpE.:ts lr F - Ecner et ,,- c0lkd _rr;,vect,vity . �A .. .. pluonat A., rer,'e Dtacy, litva,"alle to "LC bnoce Brarft circuits Isolas and/or sooage) Up to four:2 pole Eatart:BR serves Distributed Gercoarlion(DG) breakers only (not tnc§uded) - Pry 'acs ? raluct,Gn nm .et n;3 and C;onsuml,t.c rr .�"ax `., n �k, �; _. .. ., rn Utirry 10 Gateway breaker 10Ant15AjadogGE/Sierne^st Eaton included S(,"nwe MECHANICAL.. DATA X-lCi-APA .240-4C (Wx€#xD) 37 5 cm x 49 5 cm ,`1 x 16;8 cm 4.75 in x 19 5 in xb 63 in) Height is 53.5 cm— (21.66 m) wilh-ropnttng brackets ; 1✓`r -s y e -xr ..tee�kc-*.;; SOLAR CONTRACTOR X2-10 AM1 240-4C . EE 4-7 2, C 8, S. bp, r t bar' i_... u „ s CE dw'I a ,.: y CAMERON CHRISTENSEN CERTIFIED SOLAR CONTRACTOR LICENSE NUMBER: CVC57036 '3 rLG-t.51p `� „�7 Z6�€-„a ^.. w .. .., , �':AG t Arnbaent aertpE.;a:ure rarzge 4i1°Cttr+4Et"Ci 40rF to 115�9 '" C. L Ti}EeuY.P lOi ,I MOMENTUM SOLAR: P'oraite c .. €rci6sureenvtsarme�'nerating Outdoor, NRTrcertPl�ed,MEDIA type SIR, pollowbona±econstruction 5728 MAJOR BLVD. SUITE 307, ORLANDO FL.32819 CUSTOMER INFORMATION MIGDALIA GRANDE - MS139356 6806 WAGON TRAIL STREET ZEPHYRHILLS, FL 33541 . E ,e veO'li r ed vrar 2nY,d Alptdde Up 3,000 mete=s(9,842 feet) 'ti 6466103285 PV SYSTEM INFORMATION )C`, INTERNET CONNECTION OPT(6Ns SYSTEM SIZE (DC): 11.745 KW Integrated Vis Fa acEE l ab g n Ba 29 MODULES: HANWHA Q.PEAK DUO BLK k10-AS41-240- a Xi 10 N MI r r r.e xx 12 A r , 2C .c tzItn ML-G10+ 405 ., X2-€0-AMI-240-4 E, r rT7 v0-r; E a 54, 2018 < L v2 SE ,(., E,. m 29 INVERTERS: ENPHASE - Ethernet Op,rcrral fEEE 802 3 C,a.5E (of CavU U TP Et.,ernet cable (note „9eded ). IQBPLUS-72 2 US COMPLIANCE Comittitance, IQ Combiner CA Rule, 21 (UL 1741 SA) IEEE 15472018 UL 1741 SS, 31 Ed, (X2 M t M1,240 4 and XZ IQ AM? 24Q 4C) CANICSA C22 2 No 137 a Tade 47 CFR Part 15,Class B kCES 003 � �y 4 LISTED L P,odticrgln .,nc e,,,rxyI f NS3 C'�12 20 accuracy class 0 Sa(Pw pi oduceon) s PHASE. Donau r-a ia-r-oiertng. c.ervacy class 2 5 PROJECT INFORMATION 70 IE'a.l? m(DTa U�rc3Ui ECrpha SE ,;v )P""'ny5, ViS,", eit(3�1s`1SE;.yia€T1 . w4 y , r 5.-Ci [ tv , - < <, t �L24-4 CS? U3 r .S INITIAL DATE: 10/19/2023 DESIGNER: AM REV: DATE: DESIGNER: REV: DATE: DESIGNER: COMBINER SPECS UL momentum S&I .A OPEAK DUO BLK° BLK SERIES PRO CUSTOM SOLAR LLC D.B.A. MOMENTUM SOLAR 325 HIGH STREET, METUCHEN, NI 08840 I N (732) 902-6224 a Mechanical Specification MOMENTUMSOLAR.COM PR ESI L ML-G10+ SERIES ocells _ Former ... ENGINEERING Weight 4J._ F-1 C.-i .i . ' . x . ...... ��gg //gg4��gg ggi�gg gg e� �+ g 385 - i rO Wp I [32 Celis - , ,.,•. 6-1, Cover 20.9% Maximum Module Efficiency Cell E , , i =r, .>. e ..:.'v` V g ^ � r ® Electrical Characteristics�i�� ¢ POWER CLASS 38S 390 39S < 400 40S 410 t t ' ✓ ; Power at MPP' ... Yd. 3�3`s 390 355 400 40r2 A,G % Breaking the 20% efficiency barrier Short Circuit Current` A. 04 1" "14 ; ,7 C � < Z open Ci—it Voltage` V; 4S19 4523 a 2-7 453C 534 4 37 � ,- Current at MPP . ,. Ai ,.. It;.53 1065 1C7'. 53 77 'G_E?3 10.59 e Voltage at MPP ,... V 36 36 36 62 36.88 37]3 3739 27.64 l p _ L"7 ti Efficitmcy' 9.G •19.9 -: 20.1 •204 2C6 -.2C.9 , "°I EE A reliable investment •,. , .. Power MPP -W 288.8 292.E 296 J 300' x :3Q 7.6 � � � � �d'� •9i 4rareantqI �• r ., _ at & q�`�� m„ Short Circuit Current A. 890 892 8.9E 8.97 9.00 9_03 %� N � "" Open Circuit Voltage ., VI 4z4:z 42F5 4z69 c272 427E 427�i • ' Enduring high performance 2 Current at MPP A 835 84^ 846 85i 8.57 8.62 Voltage at MPP . d 34 59 3 4 S 4 0' 35 25 335.4E 35.68 . r vF 000fts PERFORMANCE WARRANTY PERFORMANCE AT I -OW IRRADJANCE C j Extreme weather rating a _ Y ! 11v .,� <„ r _ in A >25r ... Innovative all-weather technology SOLAR �O TRACTOR CAMERCERTIFIED SOLAR CONTRFACTORN£STENSEN LICENSE NUMBER: CVC57036 t`y MOMENTUM SOLAR 5728 MAJOR BLVD, SUITE 307, ORLANDO FL. 328£9 CUSTOMER INFORMATION MIGDALIA GRANDE MS139356 The most thorough testing TEMPERATMECOEFFICIENTs programme in the industry Tempc,.tareCr ff,oentof! 4 Ter,pest-a,Coeffw,er,tofV., 6806 WAGON TRAIL STREET " ZEPHYRHILLS, FL 33541 Temperature Coefficient .yf Pr,nF Nominal Module Operating Temperature .. 6466103285 a Properties for System Design PV SYSTEM INFORMATION Maximum system Vo4tzge vr.x .. _. ., PV module d—nication ciasetl SYSTEM SIZE (DC }: 11.745 KW Maximum Series Fusa Raeing ,._ Fre Rating based on ANSI �UL 61730 •iv" 29 MODULES: HANWHA Q.PEAK DUO ELK Max DaugnLond,PushrPuiF Pen-ttedModule Temperature ML-G10+405 . i� r „ ��.� ,,, MaxTest Eaad, Pushf Pmll cn Continuous Duty - 29 INVERTERS: ENPHASE . ` " iQ8PLUS-72-2-US r Qualifications and Certificates 1L 617 if t,F o;,^•priani, c' 9V 10 .. SC61 2 6 :C67 206 40- .US PR03ECT INFORMATION 'INITIAL DATE: 10/19/2023 DESIGNER: AM The ideal Solution for. ,� �, ^ C*Y119 5^9'Y �, is /1 REV: DATE' DESIGNER' �J I"E FrI£i2'liz. 27� :U`l fib= Q% .. 53,......es .:i£ ,Zmc � :Y .s _C''_.. r., �G ._-4sf�,=, .,.: o t:V F fl ✓ W,....c. •.. REV: DATE; DESIGNER: � cells PANEL SPECS PV— 1.4 ROOF PANEL COUNT TILT AZIMUTH SHADING LANDSCAPE MAX SPAN (ROOF AREA 1/2/3) PORTRAIT MAX SPAN (ROOF AREA 1/2/3) LANDSCAPE MAX CANTILEVER PORTRAIT MAX CANTILEVER Rl 8 23' 149' 100% 48 /48 /48 48 /48 /48 16 /10 /10 16 /10 /10 R2 9 23' 239' 100% 48 /48 /48 48 /48 /48 16 /10 /10 16 /10 /10 R3 8 23' 59' 100% 48 /48 /48 48 /48 /48 16 /10 /10 16 /10 /10 R4 4 23' 329' 100% 48 /48 /48 48 /48 /48 16 /10 /10 16 /10 /10 SCALE: 3/32" = V-0" GROUND ACCES` (TYR CLAMPING MAX SPACING IN ZONE 1 48" O.0 AND IN ZONE 2 AND ZONE 3 48" O.0 NOTE - ROOF COVERING MATERIAL IS COMPOSED OF SINGLE LAYER ASPHALT COMPOSITE SHINGLE, 2. EXACT ATTACHMENT LOCATION AND QUANTITY OF ATTACHMENTS ARE BASED ON EXISTING RAFTER LOCATIONS OBTAINED FROM FIELD MEASUREMENTS. THE LOCI T ION AND QUANTITY OF ATTACHMENTS MAY VARY BASED ON RAF -TER LAYOUT START POINT, SPACING VARIATIONS AND ROOFING TYPE, VERIFY IN THE FIELD ALL RAFTER LOCATIONS AND ADJUST LAYOUT AS REQUIRED. A TILE ROOF WJLL PRODUCE A STAGGERED ATTACHMENT LAYOUT BECAUSE OF EXISTING STAGGERED TILE ]DINT LLOCA'l IONS. SOLAR INSTALLER NOTES: Rl & R4 HAVE HORIZONTAL RAFTERS momentum SOLAR PRO CUSTOM SOLAR LLC D.B.A. MOMENTUM SOLAR 325 HIGH STREET, METUCHEN, NI 08840 (732) 902-6224 MOMENTUMSOLAR.COM PROFESSIONAL ENGINEERING TOTAL SQUARE FOOTAGE OF ROOF: 2306 SOFT SQUARE FOOTAGE OF SOLAR ARRAY:612.51 SQFT PERCENTAGE OF SOLAR ROOF COVERAGE: 26.57% 18" RIDGE SETBACK SHALL BE REQUIRED SOLAR CONTRACTOR CA ERON CHRISTENSEN CERTIFIED SOLAR CON Ir'FACTOR LICENSE NUMBER C.VC57036 MOMENTUMSOLAR 5728 MAJOR BLVD. SUITE 307, ORLANDO FL. 32819 CUSTOMER INFORMATION CESS SYMBOL LEGEND MIGDALIA GRANDE - MS139356 6806 WAGON TRAIL STREET ZEPHYRHILLS, FL 33S41 6466103285 MSP MAIN SERVICE: PANEL T) CHIMNEY SYSTEM INFORMATION FPV s _P I SUB -PANEL z SKYLIGHT SYSTEM SIZE (DC): 11.745 KW 29 MODULES: HANWHA Q.PEAK DUO BLK ML-GlO+ 405 29 INVERTERS: ENPHASE IQ8PLUS-72-2-US UTILITY METER z VENT FAC L2C C DISCONNECT PIPE VENT UDC UTILITY DISCONNECT UTILITY FL Cl LOAD CENTER SATELLITE DISH PR03ECT INFORMATION INITIAL DATE: 10/19/2023 DESIGNER: AM EdNEMA 3R BOX W/ ENVOY-S - FIRE SETBACKS REV: DATE: DESIGNER: El COMBINER Box MIN 3'x3'GROUND ACCESS POINT REV: DATE: DESIGNER: PANELLAYOUT MODULE PITCH DIRECTION P V —2 WIND PRESSURE ZONE LINES. REFER TO PV-2,2 FOR ADDITIONAL INFO PV MODULE RATINGS MODULE MAKE HANWHA MODEL Q.PEAK DUO BLK MAX POWER 405W OPEN CI RCU IT VOLTAGE 45.34V SHORT CIRCUIT CURRENT 11.17A NUMBER OF MODULES 29 UL1703 COMPLIANT YES �INVERTER RATINGS VOLTAGE DROP CALCULATIONS MAX OUTPUT POWER SUB PANEL SUB PANEL # OF MODULES PV BhEAKE., PER BRANCH BREAKER SIZE UP TO 16 20A i i Wire Temp. Wire Tag Conduit Wire Qty 1 Wire Type i Gauge I Rating 13/ NOTE: LETTER "G" IN WIRE QTY TAB STANDS FOR GROUNDING CONDUCTOR. momentum SOLAR % V, WIRE SIZE PRO CUSTOM SOLAR LLC D.B.A, MOMENTUM SOLAR ENGINEERING FSEC CERTIFICATION STATEMENT: PER FL. STATUE 377J05 , l, MINA A. MAKAR PE# 86753, CERTIFICATE DFAUTHORIZATION #33404,ANENGINEER LICENSED PURSUANT TOCHAPTER 471,CERT[FYTHAT THE PV ELECTRICAL SYSTEM AND ELECTRICAL COMPONENTS ARE DESIGNED AND APPROVED USING THE STANDARDS CONTAINED INTHE MOST RECENT VERSION OFTHE FLORIDA BUILDING CODE. FBC20ZO EXISTING SQUARE D2J5A MAIN SERVICE PANEL Z40V MAIN BREAKER: 20OA ENPHASE80A LINE SIDE AC COMBINER HOTTAP BOX SOLAR CIRCUIT r—DISCONNECTING MEANS EATON60AFUSIBLE AC GRID DISCONNECT || |N | H| || ||| CAMEROwCHmSTENSEw CFRrfFIED SOLAR mwTR^oo^ LICENSE NUMBER: o^,m36 MOMENTUM SOLAR ROOF 1OA/15ABREAKEJUNCTION ------- - ------_1_ UTILITY (MANUFACTURER I I 50A FUSES 7-GROUND METER 6806 WAGON TRAIL STREET BOX SUPPLIED FOR ZEPHYRHILLS, FL 33541 20A BREAKER (A) PV SYSTEM INFORMATION 20A BREAKER (B) SYSTEM SIZE (DC): 11.74S KW Wire Temp. Conduit Derated Inverter Design Ground Ground Wire IQ8PLUS-72-2-US Ampacity (A) Derate Fill Derate Arnpacity (A) Qty Correction Current (A) Size Type 35 INITIAL DATE: 10/19/2023 DESIGNER: AM R EV: DATE: DESIGNER: THREE LINE DIAGRAM 1. ALL CALCULATIONS ' x AND ISC HAVE CALCULATED USING THE MANUFACTURED STRING CALCULATOR BASED ON ASHRAEAND EXTREME MINIMUM TEMPERATURS COEFFICIENTS, 2. THE ENTIRE ARRAY IS BONDED ACCORDING TO 690.46 PARAGRAPH C). THE GROUND IS CARRIED AWAY FROM THE GROUNDING #i BARE COPPER WIRE . a COPPER WIRE. ' • •=WAIRM' • • 5. ALL CONDUCTORS ARE SIZED BASED ON NEC 2017 ARTICLE 310 6. ALL EQUIPMENT INSTALLED IS RATED AT 75`C 7. INVERTER NOC (NOMINAL OPEN CURRENT) OBTAINED FROM EQUIPMENT DATASHEET 8. CONTRACTOR SHALL BE RESPONSIBLE FOR COMPLYING WITH ALL LOCAL AND NATIONAL CODE REQUIREMENTS. 9. EACH MODULE MUST BE GROUNDED ACCORDING TO USER INSTRUCTIONS 10. ALL EQUIPMENT SHALL BE LISTED PER NEC 690.4(B) llPER 69 i! PROVIDE 1 WARNING SIGN AT ♦ LOCATIO WHERE TERMINALS OF THE DISCONNECTING MEANS MAY BE ENERGIZED IN THE OPEN POSITION> SIGN SHALLa# *WARNING - SHOCKELECTRIC 1 a•# #t NOT TOUCH1 O EQUIVALENT. 12. PER NEC 705.10, PROVIDE A PERMANENT PLAQUE OR DIRECTORY SHOWING ALL ELECTRIC POWER SOURCES ON THE PREMISES AT SERVICE ENTRANCE. 13. INTERCONNECTION METHOD SHALL COMPLY WITH NEC 705.12 14. AND OPTION FOR A SINGLE CIRCUIT BRANCH TO BE SPLIT INTO TWO SUB -CIRCUIT BRANCHES IS ACCEPTABLE. 15. ALL CONDUCTORS MUST BE COPPER, 16. NEUTRAL AND EQUIPMENT GROUNDING CONDUCTOR BONDED AS PER NEC 250.24(C). 17. EQUIPMENT GROUNDING CONDUCTOR IS CONNECTED TO A GROUNDING ELECTRODE SYSTEM PER 250.54(D). 18. FUSES FOR PV DISCONNECT HAVE AIC RATINGS OF 200KA AC AND 20KA DC. 19. SUPPLY SIDE CONNECTION SHALL BE MADE USING ILSCO INSULATION PIERCING CONNECTORS (IPC). MAKE, MODEL, AND RATING OF INTERCONNECTION CAN BE SEEN ON TABLE 1 BELOW. 20. METHOD OF INTERCONNECTION CAN BE SEEN IN FIGURE 1. 21. UTILITY HAS 24-HR UNRESTRICTED ACCESS TO ALL PHOTOVOLTAIC SYSTEM COMPONENTS LOCATED AT THE SERVICE ENTRANCE. LOCATIONS24. CONDUCTORS EXPOSED TO WET LOCATIONS SHALL BE SUITABLE FOR USE IN WET ARTICLE SECTION25. TOTAL AREA OF ALL CONDUCTORS, SPLICES, AND TAPS INSTALLED AT ANY CROSS OF DOES NOT EXCEED 75% OF THE CROSS SECTIONAL AREA SPACE,THE • 1 t .i • t .t i t # • ' i' s # # # t a i# 1 ' # : a• � t t � •i! ` 1 f • 1 # 1 t. 1. i 1..�. 1. .. 28. CONDUCTORS IN CONDUIT ARE AC CONDUCTORS BRANCH CIRCUITS AND NOT PV SOURCE CIRCUITS. .• 29. ALL GROUNDING SHALL COMPLY WITH 690.47(A) IN THAT THE AC MODULES WILL COMPLY WITH 250.64. 30. NO TERMINALS SHALL BE ENERGIZED IN THE OPEN POSITION IN THIS AC MODULE SYSTEM 690.13, 690.15, 690.6. WARNING32, ALL OR LABEL(S) SHALL COMPLY WITH 2017 NEC ARTICLE 110.21(B) AFFIXEDLABEL WARNINGS SHALL ADEQUATELY WARN OF THE HAZARD. LABELS SHALL BE PERMANENTLY TO THE EQUIPMENT,AND LABELS REQUIRED SHALL BE SUITABLEOENVIRONMENT. MAKE MODEL VOLTAGE CONDUCTOR CONDUCTOR RATING RANGE MAIN RANGE TAP ILSCO IPC 4006 600 V 4/0-4 AWG 6-14 AWG ILSCO IPC 4020 600 V 4/0-2 AWG 2/0-6 AWG INSTRUCTIONS FOR LINE TAPS FIGURE 1: 1. ADJUST THE CONNECTOR NUT TO SUITABLE LOCATION 2. PUT THE BRANCH WIRE INTO THE CAP SHEATH FULLY 3. INSERT THE MAIN WIRE, IF THERE ARE TWO LAYS OF INSULATED LAY IN THE MAIN CABLE, SHOULD STRIP A CERTAIN LENGTH OF THE FIRST INSULATED LAY FROM INSERTED END 4, TURN THE NUT BY HAND, AND FIX THE CONNECTOR IN SUITABLE LOCATION. 5. SCREW THE NUT WITH THE SLEEVE SPANNER. 6. SCREW THE NUT CONTINUALLY UNTIL THE TOP PART IS CRACKED AND DROPPED DOWN p . IN momentum SOLAR PRO CUSTOM SOLAR LLC D.B.A. MOMENTUM SOLAR 325 HIGH STREET, METUCHEN, N] 08840 (732) 902-6224 MOMENTUMSOLAR.COM PROFESSIONAL ENGINEERING CAMERON CHRISTENSEN III i"IFIED SOLAR CONTRACTOR LICENSE NUMBER: CVC57036 MOMENTUM SOLAR 5728 MAIOR BLVD. SUITE 307, ORL,ANDO FL. 32819 MIGDALIA GRANDE - MS1356 6806 WAGON TRAIL STRE39ET ZEPHYRHILLS, FL 33541 6466103285 SYSTEM SIZE (DC): 11.745 KW 29 MODULES: HANWHA Q.PEAK DUO BLK M L-G 10+ 405 29 INVERTERS: ENPHASE IQ8PLUS-72-2-US PR03ECT INFORMATION INITIAL DATE: 10/19/2023 DESIGNER: AM IREV: (DATE: IDESIGNER: I I REV: IDATE: IDESIGNER: I a' RX"91 NUAW40101M ALL WARNING SIGN(S) OR LABEL(S) SHALL COMPLY WITH NEC ARTICLE 110.21(B). LABEL WARNINGS SHALL ADEQUATELY WARN OF THE HAZARD. LABELS SHALL BE PERMANENTLY AFFIXED TO THE EQUIPMENT, AND LABELS REQUIRED SHALL BE SUITABLE FORTH E ENVIRONMENT. TAG LABEL QUANTITY LOCATION NOTE EXAMPLES 1 AT EVERY SEPARATION BY ( A I I TI 12 AC CONDUITS ENCLOSURES / WALLS / 2D UAIj _aN PARTITIONS / CEILINGS / FLOORS AC SOLAR VOLT OR NO MORE THAN 10' N w M 1 COMBINER BOX 1 1 AT ANY COMBINER BOX ELECTRICAL SHOCK HAZARD TERMINALS ON BOTH LINE AND 1 JUNCTION BOX 1 AT ANY JUNCTION BOX LOAD SIDES MAY BE ENERGIZED IN THE OPEN POSITION RATED AC OUTPUT CURRENT A NOMINAL OPERATING AC VOLTAGE 240 v POWER TO THIS SERVICE IS ALSO SUPPLIED FROM ON -SITE SOLAR GENERATION AC SYSTEM DISCONNECT DUAL POWER SUPPLY SECOND SOURCE IS PHOTOVOLTAIC SYSTEM TU", RAPID SH'TTDCEAN SWITCH TO THE-F.. 10S11 ON 10 SHUT NO - ENTIRE PV SYSTEM POWER SOURCE OUTPUT CONNECTIO DO NOT RELOCATE THIS OVERCURREr DEVICE ELECTRICAL SHOCK HAZARD TERMINALS ON BOTH LINE AND LOAD SIDES MAY BE ENERGIZED IN THE OPEN POSITION I OF EACH AT FUSED AC DISCONNECT AC DISCONNECT COMPLETE VOLTAGE AND IRSD SVVITCP CURRENT VALUES ON DISCONNECT LABEL I I UTILITY METER 1 AT UTILITY METER AND ONE DIRECTORY PLACARD 1 1 INTERCONNECTION DUAL POWER SUPPLY POINT SECOND SOURCE IS PHOTOVOLTAIC SYSTEM 1 OF EACH AT BUILDING I NTERCONNECTION POINT AND ONE DIRECTORY PLACARD BACKFEED PANEL I f AC CURRENT PV MODULES N IQ 18 w, @ BACKFEED momentum SOLAR PRO CUSTOM SOLAR LLC D.B.A. MOMENTUM SOLAR 325 HIGH STREET, METUCHEN, NJ 08840 (732) 902-6224 MOMENTUMSOLAR.COM PROFESSIONAL ENGINEERING CAMERON CHRISTENSEN CERTIFIED SOLAR CONTRACTOR LICENSE NUMBER. CVC57036 MOMENTUM OM ENTU M SOLAR 5728 MAJOR BLVD. SUITE 307, ORLANDO HIT. 32819 CUSTOMER INFORMATION MIGDALIA GRANDE - MS139356 6806 WAGON TRAIL STREET ZEPHYRHILLS, FL 33541 6466103285 PV SYSTEM INFORMATION SYSTEM SIZE (DC): 11,745 KW 29 MODULES: HANWHA Q.PEAK DUO BLK ML-G10+ 405 29 INVERTERS: ENPHASE IQ8PLUS-72-2-US PR03ECT INFORMATION INITIAL DATE: 10/19/2023 DESIGNER: AM REV: DATE: DESIGNER: REV: DATE: DESIGNER: Ek-MPMENT LABELS PV-3.2