HomeMy WebLinkAbout23-7400Zeiphyr"hills
WIT
Issue Date: 12/12/20•
2L.—.—]
11 26 21 0010 20200 0180 1 5128 17Th Street
Name: BILLIE GARCIA & RICKIE GARCIA Permit Type: Electric Service Replacement/M
NOTHSTEIN i Class of Work: Add/Alter Residential I
Address: 5128 17Th St
ZEPHYRHILLS, FL 33542
Phone: (813) 715-1443
Building Valuation: $0.00
Electrical Valuation: $28,726.00
Mechanical Valuation:
Plumbing Valuation:
Total Valuation: $28,726.00
Total Fees: $183.63
Amount Paid: $183,63
Date Paid: 12/12/2023 10:41:17AM
L
REINSPECTION FEES: (c) With respect to Reinspection fees will comply with Florida Statute 553.80(2)(c) the
local government shall impose a fee of four times the amount of the fee imposed for the initial inspection or
first reinspection, whichever is greater, for each subsequent reinspection.
Notice: In addition to the requirements of this permit, there may be additional restrictions applicable to this property that
may be found in the public records of this county, and there may be additional permit required from other governmental
entities such as water management, state agencies or federal agencies.
ilylillill 111 111111 111 111 !11 !!111 111 iligpill :I III, I Jill III 1 111111 1111 111111 111 11111 1
I I
L
Complete Plans, Specifications add fee Must Accompany Application. All work shall be performed in
accordance with City Codes and Ordinances. NO OCCUPANCY BEFORE C.O.
NO OCCUPANCY BEFORE C.O.
CONTRACTOR SIGNATURE
Ilia it
C
MEF-E;l E PE IT OFFI
h=- F"MI-4,11--iltod'"I'M -
171 1 104-1 1
813-780-0020 City of Zephyrhiiis Permit Application Fax-813-780.0021
Building Department
Data Received Phono Contaot rorPrami din s
Owner's Name Billie Garcia Owner Phone Number 813-715-1443
Owner's Address 5128 17TH STREET. ZEPHYRHILLS, FL 33542 Owner Phone Number
Fee Simple Titleholder Name �.m.. Owner Phone Number
Fee Simple Titleholder Address
JOB ADDRESS 5128 17TH STREET, ZEPHYRHILLS, FL 33542 LOT #
SUBDIVISION PARCELID# 11-26-21-0010-20200-0180
(OBTAINED FROM PROPERTY TAX NOTICE)
WORK PROPOSED NEW CONSTR ADD/ALT SIGN DEMOLISH
INSTALL REPAIR
PROPOSED USE SFR E:] COMM OTHER
TYPE OF CONSTRUCTION BLOCK FRAME STEEL
DESCRIPTION OF WORK Install Photovoltaic Renewable Energy Solar System On the rt7Ot
BUILDING SIZE SO FOOTAGE= HEIGHT
BUILDING a VALUATION OF TOTAL CONSTRUCTION
ELECTRICAL S AMP SERVICE PROGRESS ENERGY = W.R.E.C-
PLUMBING S
MECHANICAL 5 VALUATION OF MECHANICAL INSTALLATION
GAS ROOFING SPECIALTY = OTHER
FINISHED FLOOR ELEVATIONS FLOOD ZONE AREA ®YES NO
BUILDER COMPANY
SIGNATURE REGISTERED Y / N FEE CURREN
Address LIC@flS@ #
ELECTRICIAN COMPANY
�®�
[::::
SIGNATURE REGISTERED Y / N FEE CURREN Y / N
Address License #
PLUMBER
E===
SIGNATURE REGISTERED Y (N FEE CURREN �" Y ( N
Address ====== Licens@ #
MECHANICAL COMPANY
,SIGNATURE REGISTERED Y (N PE�-R---�
Address License#
OTHER � COMPANY Freedom Solar Energy LLC w
SIGNATURE REGISTER EA Y / N FEE CURREN
Address 3 139 PineEluff Loop, Dade City,FL,33525 License# CVC56990
Ifot�tS8i1�i$#[g@5Q!#�t�i5i#i@d11t115Qtt�lt8[Itift0���Q;
RESIDENTIAL Attach (2) Plot Plans; (2) sets of Building Plans; (1) set of Energy Forms; R-O•W Permit for new construction,
Minimum ten (10) working days after submittal date. Required onsite, Construction Plans, Stonnwater Plans w/ Slit Fence Installed,
Sanitary Facilities & 1 dumpster, Site Work Permit for subdivisionstlarge projects
COMMERCIAL Attach (2) complete sets of Building Plans plus a Life Safety Page; (1) set of Energy Forms, R-O-W Permit for new construction.
Minimum ten (10) working days after submittal date. Required charts, Construction Plans, Stormwater Plans w/ Silt Fence installed,
Santary Facilities & 1 dumpster. Site Work Permit for all new projects. All commercial requirements must meet compliance
SIGN PERMIT Attach (2) sets of Engineered Plans.
****PROPERTY SURVEY required for all NEW construction.
Directions;
Fill out application completely.
Owner & Contractor sign back of application, notarized
If over $2500, a Notice of Commencement Is required. (AtC upgrades over $7500)
Agent (for the contractor) or Power of Attorney (for the owner) would be someone with notarized letter from owner authorizing same
OVER THE COUNTER PERMITTING (copy of contract required)
Reroofs if shingles Sewers Service Upgrades A/C Fences (Plot/Survey/Footage)
Driveways -Nat over Counter if on public roadways -reeds ROW
•^nr Im'soyffill
813-780-0020 City of Zephyrhills Permit Application Fax-813-780-0021
Building Department
NOTICE OF DEED RESTRICTIONS: The undersigned understands that this permit maybe subject to "deed" restrictions' which maybe more restrictive
than County regulations. The undersigned assumes responsibility for compliance with any applicable deed restrictions.
UNLICENSED CONTRACTORS AND CONTRACTOR RESPONSIBILITIES: If the owner has hired a contractor or contractors to undertake work, they
may be required to be licensed in accordance with state and local regulations. If the contractor is not licensed as required by law, both the owner and
contractor may be cited for a misdemeanor violation under state law. If the owner or intended contractor are uncertain as to what licensing requirements
may apply for the intended work, they are advised to contact the Pasco County Building Inspection Division —Licensing Section at 727-847- 8009.
Furthermore, If the owner has hired a contractor or contractors, he is advised to have the contractor(s) sign portions of the "contractor Block" of this
application for which they will be responsible. It you, as the owner sign as the contractor, that may be an indication that he is not properly licensed and is
not entitled to permitting privileges in Pasco County.
TRANSPORTATION IMPACT/UTILITIES IMPACT AND RESOURCE RECOVERY FEES: The undersigned understands
that Transportation Impact Fees and Recourse Recovery Fees may apply to the construction of new buildings. change of use in existing buildings, or
expansion of existing buildings, as specified in Pasco County Ordinance number 89-07 and 90-07, as amended. The undersigned also understands, that
such fees, as may be due, will be identified at the time of permitting. It is further understood that Transportation Impact Fees and Resource Recovery
Fees must be paid prior to receiving a certificate of occupancy" or final power release. If the project does not involve a certificate of occupancy or final
power release, the fees must be paid prior to permit issuance. Furthermore, It Pasco County WatenSewer Impact fees are due, they must be paid prior
to permit issuance in accordance with applicable Pasco County ordinances.
CONSTRUCTION LIEN LAW (Chapter 713, Florida Statutes, as amended): If valuation of work is $2,500.00 or more, I certify that 1, the applicant,
have been provided with a copy of the "Florida Construction Lien Law —Homeowner's Protection Guide" prepared by the Florida Department of
Agriculture and Consumer Affairs, If the applicant is someone other than the "owner', I certify that I have obtained a copy of the above described
document and promise in good faith to deliver it to the "owner" prior to commencement.
CONTRACTOR'S/OWNER'S AFFIDAVIT: I certify that all the Information In this application is accurate and that all work will be done in compliance with
all applicable laws regulating construction, zoning and land development. Application is hereby made to obtain a permitto do work and installation as
indicated. I certify that no work or installation has commenced prior to issuance of a permit and that all work will be performed to meet standards of all
laws regulating construction, County and City codes, zoning regulations, and land development regulations in the jurisdiction. I also certify that I
understand that the regulations of other government agencies may apply to the Intended work, and that it is my responsibility to identify what actions I
must take to be in compliance. Such agencies include but are not limitedto:
Department of Environmental Protection -Cypress Bayheads, Wetland Areas and Environmentally Sensitive
Lands, WaterA/Vastewater Treatment.
Southwest Florida Water Management District -Wells, Cypress Bayheads, Weiland Areas, Altering
Watercourses.
Army Corps of Engineers -Seawalls, Docks, Navigable Waterways.
Department of Health & Rehabilitative Services/Environmental Health Unit -Wells, Wastewater Treatment,
Septic Tanks.
US Environmental Protection Agency -Asbestos abatement.
Federal Aviation Authority -Runways.
I understand that the following restrictions apply to the use offill:
Use of fill is not allowed in Flood Zone `V` unless expressly permitted.
If the fill material is to be used in Flood Zone "A", it is understood that a drainage plan addressing a
"compensating volume" will be submitted at time of permitting which is prepared by a professional engineer
licensed by the State of Florida,
If the fill material is to be used in Flood Zone "A" in connection with a permitted building using stem wall
construction, I certify that fill will be used only to fill the area within the stem wall.
If fill material is to be used in any area, I certify that use of such fill will not adversely affect adjacent
properties. If use of fill is found to adversely affect adjacent properties, the owner may be cited for violating
the conditions of the building permit issued under the attached permit application, for lots less than one (1)
acre which are elevated by fill, an engineered drainage plan is required,
If I am the AGENT FOR THE OWNER, I promise In good faith to inform the owner of the permitting conditions set forth in this affidavit prior to
commencing construction I understand that a separate permit may be required for electrical work, plumbing, signs, wells, pools, air conditioning, gas, or
other installations not specifically included in the application. A permit issued shall be construed to be a license to proceed with the work and not as
authority to violate, cancel, after, or set aside any provisions of the technical codes, nor shall issuance of a permit prevent the Building Official from
thereafter requiring a correction of errors in plans, construction or violations of any codes. Every permit issued shall become invalid unless the work
authorized by such permit is commenced within six months of permit issuance, or if work authorized by the permit is suspended or abandoned for a
period of six (6) months after the time the work is commenced. An extension may be requested, in writing, from the Building Official for a period not to
exceed ninety (90) days and will demonstrate justifiable cause for the extension. If work ceases for ninety (90) consecutive days, the job Is considered
abandoned.
WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR
PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT
ca ^o A Ki A-r-re%op
FLORIDA JURAT (F,S. 117.03) 12 J
OWNER OR AGENT_ CONTRACTOR
2N subscribed
Subscribed and sworn to (or affirmed) before me this suson . andsom to (or affirmed) before me this
—by_ —b _
Who is/are personally known to me or has/have produced In is/are personally known tome or has/have produced
as identification, lan��=s identification.
Notary Public Notary Public
Commission No.---------- Commission No..te-
A
Name of Notary typed, printed —or stamped SN;Ym-e`b1N.1. ty�pelprinld�palm ci���
, RA P I KASIE LYNN VAUGHAN
Notary Public - State of Florida
Commission # RH 414246
My Comm, Expires Jun 26, 2027
Bonded through National Notary Assn.
M—
Inverter Type:
(20)IQ7HS-66-E-ACM-US
PV Panel:
(20) SunPower SPR-M440-H-AC
Racking:
Invisimount Rail
'Total Wattage:
8.80OW DC
Roof Type:
Composition Shingles
Wind Load:
7 to 20 Deg
Fastener Type:
Use K2 Splice Foot
Sheet Index
S-1
Cover Sheet / Site Plan
S-2
Detail
E-1
One - Line
E-2
Electrical Code
S-IA
Mounting Plan
General Notes:
-IQ7HS-66-E-ACM-US Micro Inverters
are located on roof behind each module.
-First responder access maintained and
from adjacent roof.
-Wire run from array to connection is 40 feet.
fi
FAMMOCA4 SMAJU EMERA'
5739 (,all Blvd.
Zephyrhills FL, 33542
913-395-5956
R-1
# Modules (20)
Pitch: 200
Azimuth.- 269'
so
1 0 0
t 1111, lt%�� M,_-tcr
I N011
nnucl M", o t NJ IP k
viH
11 Z
Meets All Editions of Florida Fire Prevention Code 2020 7tli �`dition
-Jegend
First responder access
Meets all requirements of 2018 Editions of NFPA-I and NF' A-101
Chimney
i_t
M C t C I-
/X
Satellite
Represents all Fire Clearance I st Responder Access
11V D , isconflect
Vent Pipe
including Alternative methods minimum of 36" unobstructed as per
Section R324 of the 2020 IRC
Meets the requirements of the following- (2020 FL Residential Code & FBC, 7th Edition (2018 International
Residential Code) - 2nd Printing modified by the FL Building Standards, 2020 Florida Building Energy
Conservation Code 7th edition, County of Zephyrhills Code, 2017 National Electric Code.)
Customer Info:
BILLIE GARCIA
5128 17TH ST
ZEPHYRHILLS, FL
33542
Layout Subject to Change Based on Site Conditions
Godwin Engineering and
Design, LLC
8378 Foxtail Loop
Pensacola, FL 32526
D. Chad Godwin, PE
Chad(t1i,,godwineng.com
Date: 11/30/2023
Revised by:
Rev#: 00
N
Roof Type: Composition Shingles
Roof Pitch & Overhang: 4/12, 12" Overhang
Seal ing/F I ashing:
Extra Notes:
(2) M5x6Omm SS Screws into Roof Rafters
2"x4" Wood Trusses (oi 24" O.C.
All penetrations are sealed and flashed
K-7'2 sp% I ice fool
Rafter S ans Zone I LZ�i:ine�q
Zone 2n_ Zone 2r_ Zone 3e 3r_
7244 48"
48ff
48" 48"
_Zone
24"
Non - ,Exposed 1 72" 48"
48"
48" 48"
48"
11 o o, f t I e i g1h, t 151
Customer Info:
-"( -e I'V
t A the - "I"Itoof Mot]
sysfic-111'
Inverter Type-
(20)lQ7HS-66-E-ACM-US
I- , nl'-'cdl
PV Pan
(20) SunPower SPR-M440-H-AC
w i I I b e s ut ject t o t li, e f o,') I I o, w i ncy td e s i,,- 111
1- 1 1 C 1, 1"A
Racking
Invisimount Rail
BILLIE GARCIA
Desion Wind re
Speed(Vuflt) - 140tnpht 3
see (Yust,
Total Wattage-
8,800W DC
5128 17TH ST
Ex,posure ('41fi
Roof Type-
Wind Load-
Composition Shingles
7 to 20 Deg
ZEPHYRHILLS, FL
-111)esi;-,;-,n,ed as per AS(T1746
Fastener Type:
Use K2 Splice Foot
33542
Godwin Engineering and
Design, LLC
8378 Foxtall Loop
Pensacola, FL 32526
D. Chad Godwin, PE
Chad((7godwineng.com
' Mk
r"ECKMSM-Ar. rwpw
5739 G311 Blvd.
Zcphvrhills F-1, 33542
Date: 11/30/2023
Drawn by:il PP
Revised by:
Rev
Rev Date:
Page:
NEMA 3R
Junction Box
Black - 1, 1
Red - 1,2
Green - Ground
12-2 Roniex can be used for interior
building and attic runs only. Do not use
rornex in conduit or outdoor
environments.
jl 10 AWG FIIWN for I forne runs
1) Line I
(1) Line 2
2 Circuits
(1) [;(ic
Inside '�i, least 3 4" Conduit (tbd on site)
12AWG TIIHN-THWN-2
LJL 9703
Grounding Conductor to be protected
#8 Awg or to be unprotected #6 Awg
250.64(B) 250.66 & 250.120(C)
I RATED AC OUTPUT CURRENT r2A
NOMINAL OPERATING VOLTAGE 240VAC
125 Load Center
Micro Inverter Output Ckt Per String
To Overcurrent Protection Device
15A 10A
AC Max Output Current 1
MA 'e
AC Max Output Current 125% 20,0
Overcurrent Protection (A) 20
20A
No. of Current Carrying Cond <4
Conductor Gauge (AWG) 10
Micro Inverter Total Output Ckt
PVS6
AC Max Output Current
AC Max Output Current * 125%
Overcurrent Protection (A)
No. of Current Carrying Cond
Conductor Gauge (AWG)
In Case of Emergency Call
Freedom Solar
Photovoltaics:
(20) SunPower SPR-M440-II-AC
Inverters:
(20) IQ7HS-66-E-ACM-US Micro Inverters
Circuits:
(2) circuits of (10) Modules
Maximum Inverters Per 20A Circuit (10)
,0A Sus. cc Retcd
Fused Disc—n-t
40A Fuses
ACoisconnect
Nni to 6autt ,d 13—d
Conduit (in}' LI,L2,N Awg Ground lAwgl OCPD
I
After Combing _B 0.75 8 8 40
To Line Side Tala C 035 1 6 N/A 40
Note:
-All wiring to meet the 2017 NEC and
Florida electric codes.
60A Disconnect
-Type of conduit to be determined
on site by contractor.
I n S C i Ic, i ti t f r
G1 V No YFS
t s% �Icm Pei 690,41 (A)( 1)
(&C ml he in,,Iuffled Im ?50,64
6L(' mu�t h-c "onlinuou'i im-'plickA ph'-ed lronn
)Hkerleto cxisllnlcice -round 4 tcm m f'yofn the
arra\ti to scr,,ice groumi �,�stem
Gk( nwst be mill --"8 AV, G and Insiall"A In conduit
It'( 0-( 1, not in conduil, itsnut he ;:6 mmi
0 H IN 01!_
,�nd �thin of mlii� mictor
Aj
X, F rcHcC'H%,,_, :111"d ;ffl `01 1 i 1:1
Main Service Panel
150A Main
Supply Side Tap
BILLIE GARCIA
5128 17TH ST
ZEPHYRHILLS, FL
33542
NEC I ABEL NOTES
I Ted'AlARNING SIGN(SON I ABEUS) SiU COMPLY
OATH NEC 110,21r13)
2 LABELS SHALL BE SU!TABI E R 'I HEE ENVtRONMPNT
'AjHERE THEY ARE INSTALLED,
33 LAPELS DO BE A MEN 1�OTTER HEIGH, OF 3,'8' AND
PERMANENTLY AFFIXED.
4 LABELS SHALL At SO C OMPI Y "APITH -HE SPECIPIC
REQUIREMENT A OF TH_AU T HOR11 HAVING
A,RISOIC TION
'M h': 'e,
Godwin Engineering and
Design, LLC
8378 Foxtall Loop
Pensacola, FL 32526
D. Chad Godwin, PE
Chad (o .,godwineng.com
IteYet to NFC 312 8 for
Conditions on taps in s,a,h
-do— current devices
E.cI(,s,i,,s
If the conditions are not
met a tap box will
need to be installed
and w,,swn wnylcted
N\\ C
0
40 it C
N 1360
e
eoAr
A\
op, I
x
Zf)AIA
L
/111111wO IAI�)
57.39 Ciall Blvd,
Zephyrhills FL, 33542
813-395-5956
Date: II/30/20_4
Drawn by: pp
Revised by:
Rev Date:
5
Inverter 'l'ype:
IQ711S-664 '-ACMJJS
11V Panel:
(20)
Sunflokker 51'R-M44011-ACI
"Total Wattage:
8,180OW DC
NEC225
- Disconnect means shall be provided for disconnecting all ungrounded
conductors that SLIPPIX or pass through the building or structure Per Code
2017 NEC Section 225.31 & Section 225.32
NEC 230
- if multiple service disconnects are present, grouping ot'disconnects will be
done Per NEC 230.72
N I C 690
- Rapid Shutdown Built in Per Code NEC 690.12
- F 04 . Construction documents specify IIV system circuits installed on or in
buildings include a rapid shutdown function unction that controls specific
conductors in accordance with NEC article 690.12.
- E05. These construction documents specify that a label is provided with the
method to initiate rapid shut down per 69(. 12(4).
- E06. Construction drawings specify buildings or structures with both utility
service and a PV system, complying with NEC article 690.12 shall have a
permanent plaque or directory including the following wording: "PI10TO
VOLTAIC SYSTEM 1--QIJIPPED WITH RAPID SIRTTI)OWN" as per
NEC article 690,56 (C).
- E07. Construction documents specify PV power circuit labels shall appear
on every section of the wiring system that is separated by enclosures, walls,
partitions., ceilings, or floors.
- F08. Construction documents specify all warning signs) or label(s) shall
comply with NEC article 11021 (B). Label warnings shall adequately warn
of the hazard. Labels shall be permanently affixed to the equipment. and
Labels required shall be suitable l'or the environment.
NEC 705
PV AC disconnect is lockable in the open position per code NEC. 70522(7)
Photovoltaic AC disconnect shall be capable of being locked in the open
position per NEC article 705.22(6),
Photovoltaic AC CiverCUrrent protection shall be located within 10 feet of
the point where conductors are connected to the service per NEC 705.3 1,
- In compliance with NEC 250.58, NEC 690.8. NEV 250.24, NEC250.24(1))
- System meets the grounding requirements of NFC 69043
Grounding Electrode:
- All grounding Electrodes will be at meter or MDP
- Ground Rods to be at least 8' long, mid 5/8" in diameter per NEC
250.52(A)(5)
- Add supplemental electrode as required
- System meets requirements ofNE'C250.50
VER
- All Exterior equipment is a minimum of Nerna-R.3 Rated
- Smoke Alarms per F.S. 553.883
- All Electrical Service Equipment shall be located at or above BFF1'+ Yor
8.00'NAVf)
am
Install will be done to Manufacturer Spec
Service Conductors are Parallel
No interconnections to be performed on inside panels unless stated by the
contractor.
Fhe Contractor shall Be responsible for verifying all existing conditions,
and for conforming with these drawings in the event of any unforeseen
circumstances.
plans Satisfy NEC 250.94 & NEC250_53(A)(2)
Note:
- Subject PV Systems has been designed to meet the requirments of the NEC
2017. and those set forth by the Florida Solar Energy ('enter Certification,
Including Maximum Number of Module Strings. Maximum number of'
modules per string, Maximum Output, Module Manufacturer and model
number, inverter manufacturer and model number, as applicable.
no=
Markings shall be placed on all DC Conduits. DC Combiners, Raceways,
Enclosures, Junction Boxes. and Cable Assemblies at every 10', turns, and
above and below penetrations in compliance with NFPA
All Interactive System(S) Points of interconnection with other sources shall
be marked at an accesible location at the disconnecting means as a power
source and with tire rated au output current and the nominal operating AC
voltage. Per NEC 690.54
Labels will be placed in the correct location per Code NEC 690.56(13),
690.56(C), & 690,53
Include required label for metallic raceways and conduits per NEC article
690.31(G)(3).
Add required label per NEC article 705.10.
Markings Shall Be reflective, Weather Resistant and suitable for the
environment.
Markings Shall be red with white lettering with minimum 3/8" Capital
Letters
NEC 705.10 A permanent plaque or directory, denoting the location of
all electric power source disconnecting means on or in the premises, shall
be installed at each service equipment location and at the location(s) of
the system disconnect(s) for all electric power production sources capable
of, being interconnected. One sign required for each PV system.
SOLAR PV SYSTEM EQUIPPED
3/8 IN MIN TEXT WITH RAPID SHUTDOWN
TURN RAPID
SHUTDOWN SWITCH TO
3/16 IN MIN, TEXT THE "OFF" POSITION TO
SHUT DOWN PV
SYSTEM AND REDUCE
SHOCK HAZARD IN THE
ARRAY,
TERMINALS ON THE LINE AND
LOAD SIDES MAY BE ENERGIZED
IN THE OPEN POSITION
0
sECM WCrli AND 14FFA ` I I f,11 Q 21A
DUAL POWER SUPPLY
SOURCES: UTILITY GRID
AND PV SOLAR
ELECTRIC SYSTEM
Apply to Main Disconnect
In Case of Emergency Call
Freedom Solar
- V11, A CIGG"I uO G"I'sc -1 ; -t e
BILLIE GARCIA
5128 17TH ST
ZEPHYRHILLS, FL
Electrical Calculations
tnverter Output Ckt
To 0,sprcurrent Protection Device with Cooper
Max Amb Terrop Range(F)
Temp Rating, of Conductors (C)
Current Carrying
AC Max Output Current
AC Max Output Current * 1,25%
Overpurrent Protection(A)
Amp Ternit Correction Factor
Raceway Fill adjustment Factor
Wire Size(Awg)
Cond, Aflowable Arnpacity(A)
Conn Adju sted Ampacity( A)
Ampacoty Check I Per 690,8(8)(1)
AmilacitV Check 2 Per 690.81B)(21
14
87-95
75'C
<4
310,15(8)(3)(a)
32A
690.8(A)(3)
49A
699.818)
40A
0,94
310,15(g)(2)(a)
100%
31G,15(8)(3)(a)
8
310,15(8)(16)
5GA
47A
50A*1*0.94=47A
Pass
32A*1,25=40A<50A Pass
Pass
50A'0.94A'1=47A>32A Pass
Godwin Engineering and
C
0
01 Vk
Design, L.L.0
81360
8378 Foxtail Loop
Pensacola, FL 32526
_Z7
0
D. Chad Godwin, PE
40RIO�` # 'Z�
Chad Cip godwi Deng. corn
OJVAL VO� xx
5739 Gall Blvd,
Zcphyrhills FL. 33542
913-395-5956
Date: 11/30/2023
Drawn by: PP
Reyised,ky:
Rev #: 00
lev Date:
Inv erter"Type:
IQ71 IS-66*--ACM-1 JS
PV Panel:
(20)
SunPower SPR-M440-1 ]-AC
Tonal Wattage:
8,80OW DC
H J 1 CMrc�, S I nstadi � 111 lbe' don, C o �
9 4 Proposed Mounting locations
12 mSplice 1113ar
32 K2 Splice Foot
36 Invisimount UFO's
9 Invisimount Sleeves/End Caps
I Roof Top Combiner
2 Invisimount Ground Lugs
20 SunPower SPR-M440-H-AC
I 60A Fused Disconnect
2 40A Fuses
2 20A 2P Breakers
I 125A Load Center
I PVS6 Device
Rafter Spans
Zone I
Zone 2e 1 Zoneln
Zone 2r
Zone 3e Zane 3r
Exp9sed
72"
49" 48"
48"
48" 24"
Non -fix �_
72"
49" 1 48"
48"
48" 48"
Max Cantilever
2"
1611 16"
16#f
16" 16"
Max Cantilever = Max Span I
Inverter Type:
PV Panel:
Racking:
Total Wattage
Roof Type:
Wind Load:
Fastener Type
R-1
# Modules (20)
Pitch: 200
Azimuth: 269'
(20)IQ7HS-66-E-ACM-US
(20) SunPower SPR-M440-H-AC
Invisimount Rail
8,80OW DC
Composition Shingles
7 to 20 Deg
Use K2 Splice Foot
Customer Info:
BILLIE GARCIA
5128 17TH ST
ZEPHYRHILLS, FL
33542
o
n 10 Vfil �i
q Go
NX
Godwin Engineering an
Design, LLC
eN 1360
8378 Foxtall Loop
V
Pensacola, FL 32526
0
D. Chad Godwin, PE
ORIV,-
Chad(0/godwineng.com
//jAmLIkO 1 3
V
rs&m,
5739 Gall Blvd,
Zephyrhills FL, 33542
913-395-5956
Date: 11/30/2021
Rev 9: 00
Rev ate®
Page: lift xlT S-lA
to
Part of the SumPower
Equinox Solar System
Compatible With
mySunPbwerT°," monitoring
Seamless aesthetics
r
2 -4 OW Residential AC Module
Built specifically for use with the SunPower Ecjuinox` system, the only fully
integrated solar solution designed, engineered, and warranted by one company.
Highest Power AC Density Av%ail;able..
The patented, solid -copper foundation Maxeon Gen 6 cell is over
5% larger than prior generations, delivering the highest efficiency
RC solar parcel available.'
l highest Lifet€rne. Energy and `+a`sir,,g_";
Designed to deliver 60% more energy over 25 years in
real -world conditions like partial shade and high temperatures.l
Best fl.eliarlilit y, Best Warranty
With more than 42.6 Killion and 15 GW modules deployed around
the world, SunPower technology is proven to last. That's why we
stand behind our module and microinverter with the industry's
best 25-year Combined Power and Product Warranty.
M_Se i s. M4401 M435 � M43 1 M42 5 g M420 SunPower® Residential AC Module
k{I-A(
°tom Power (P, o r) !1
440E, - 430
G2 ; 420
PcrverTole,ance
oc. IF Effic<ercy
212s3% 2 3r4
7 0%- 21 7✓s,
emp Coef (Povieri
-
-029%/ C
i
Shade Tolerance
ted module-leiel max p.✓.e,
ooir-, -r,u<ing
oce a-ng Temo
F-c 85'F'-+ to FS'C,
Max Amb�entTemo
22'r-(50'C) - - -
- -
'lax Tesr! Load-
r 6000 > k it back
i c 1�> os
_..
snc /r '8_7 psf 9000 Fa 01 7 l g/rn''ront
ryaa Design Lo
vvinc 7 sf 3600 �a ^7 r,Jrr' baw_.
_
e o oao
7no v ',25 p,f, 6000 Fa, 61` k,/r-'rrcnt
rr pact Res st<, ce
r ch (25 mnr afar titer , ail oC 52 mor `3 rrts'
Solar Cells
66 K/axecn Gen 6
Front Glass
H ah -ra ,rrission terrcered glass mth arts re
lecti✓e oatmc
Er✓ ronmertal Rat n
utdcor ,,ec
Fralre
Class docka�odlzed(,ighestAtNAra rg)
/e bh
48 lb `2 1 8 v,;)
Reccm� cec Isla
3
fAo,l de so c nF
,.,rant
25✓e .r iimi-ed GO Me °harra'lty
-S
e r h i 'cd crodut, spr`ant;
E FIE 547
7A1 AC Module (Type 2 fire rated)
6:7='0
.�_ 62107-1 r IEC 6210R-_
FCC Par` i S Class B
ICES-0003 Class B
AP /CSA-C 10 107 1-0`
CA. u'e2i (UL 1741 `AI
CerT `f':a=ialSS
( rdudes Vol Nar and P c IVe P V,✓er Pr:c,rvy
ra
Lasted P / Rao d Sr utdoAn Ep prre^t
I-nmolia-^f2
_
�_. G ".0 Ala o` In aC..Ordance ,vfLh:
c (AC rnoc.le)
N C 590 t2 Rap d Sh odov,^ (Inside and outside
arfay)
C 630 i SAC :on-e _C ,: 600 _))1)
Inen s-
AC module Q Cables and accessories
'U 670+ arid UL 223S)
Pacer, for load r✓ ea c di sco r r ect
PID "Test 1000 V {EC 5180E
Modales per pallet Z5
75 v t 2ru80in
P ckarfb bon d ersiors _ 6 k 1110 rnm)
r'alfet b' c s vvclA-t 306 i la (5 ,0 lz K)
Pallets o2 n ai er r
Net veilg-i per co taine, 62 E io C n c4O'A;
t, 12 .^�
°i < `:1 r
vp,f.r _ �',. „- r•1 , r, f
,, a n :,,r 1�,� u - i„[ i /r I;.�,,.,
Fit
Jr get to r., .. .. r,1 vu ,.
. r., ,°i ,`i., ..:rol ,,,l .'rPF(� , F`✓`t `f
I,P.a, ,,_ x,r°fF ;<<^
T r,,I i ..I V °"fl=ty
,
r., t,.
f r r r✓ { t
=1 s V I . r . fully
f (,. 1 "k ac 1
s
r ....°rp,r r-° ,, ,f.,r,: V,'
> lu., u,,da-, f - °re , ,ar,._
All F, hlv ld 1"F
UL
USTED
Nia ,4e Gera Pe.4arm-cr,ce. iypa z
5399 7:1, RevB
January 2022
F|�xi�|2 D2S'-n
^ Add�s�sneadyaUsk�ed�sk�nba um�
' Des�n|n|andscapeandpoora|c
' Ra||�enab|eeasyobs�ac|emana&emenc
'
P�����up�riOrSvs��nl
' B-it kxusew|chSunPowerD[andA[modu|es
BesHn�|asssys�mreUabUi�andaemhe�o
' [omNnewiUhSunPn�ern��uksand
monKodn�app
sUnpoVVleF.[OOO