Loading...
HomeMy WebLinkAbout24-7590�,-,, City of Zephyrhilis 1 vt v ttt t 5335 Eighth Street ephyrhill , FLU 33542 � rELCMISC-007590-2024 Ze hyrhills Phone: (13) 780-0020 P Fax: (313) 73-021, issue gate: 02101t2024 Electric Service lacement/Misc 1126 210010 03500 0081 38401 12Th Avenue 7 77777 7774 Name: JEFFREY LIND Permit Type: Electric Service Replacement/Contractor: FREEDOM FOREVER Class of Work: Add/Alter Residential FLORIDA LLC � Address: 38401 12TIT Ave Building Valuation: $1,00 o f l ' ZEPHYRHILLS, FL 33542 Electrical Valuation. $10,432,0 1 Phone: (321) 247-6073 Mechanical Valuation., Plumbing Valuation. � � � �t�� 1 Total Valuation: $10,433.00 Total Fees: $18.24 Amount Paid: $138.24 Date Paid: 1/412024 1118:53AM INSTALLATION PHOTOVOLT1AC SOLAR PANELS ON RGT REAR WIN SIDE OF BIOME //PANEL INSTALLED ON ES BP 2791 t 777 t ttit:. t t \ 77 Electrical Permit Fee" $92.16 Electrical Plan Review Fee $46.013 Ifs p "rI N FEES: (c) With respect to Reinspection fees will complywith Florida Statute 553. p(2)(c) the local government shall impose a fee of four times the amount of the fee imposed for the initial inspection or first reinspection, whichever Is greater, for each subsequent r in p cti n® Notice: In addition to the requirements of this permit, there may be additional restrictions applicable to this property that may be found in the public records of this county, and there may be additional permit required from ether governmental entities such as water management, state agencies or federal agencies. "Warning to owner: Your failure to record a notice of commencement may result in your paying twice for improvements to your property, if you intend to obtain financing, consult with your lender or an' attorney before recording your notice of commencement." Complete Plans, Specifications add fee Must Accompany Application. All work shall be performed in accordance with City Codes and Ordinances. NO OCCUPANCY BEFOREC.O. NO OCCUPANCY BEFORE C.O. CON Tt C 'SIGNATUP ' PE IT OFFICE WITHOUTMIT EXPIRES IN 6 MONTHS INSPECTION CALL FOR INSPECTION NOTICE DocuSign Envelope ID: 36F73693-5BF6-40B7-8E94-931DFD1A25E3 �uV. ,,pjjS i�rrCtl$ Application Fax-$13-780-0021 r Building Department Date Received 1 /31 /2024 Phone Contact for Permitting ( 727 ) 294 _ 7218 Y Owner's Name Owner Phone Number (813) 616-0412 enue, e yr s, Owner's Address Owner Phone Number Fee Simple Titleholder Name Owner Phone Number Fee Simple Titleholder Address t Avenue, zep yr i s, F JOB ADDRESS LOT a#, 9, 0 SUBDIVISION PARCEL ID# 11-2&-21-aa1a-D35aa-aQa1 (OBTAINED FROM PROPERTY TAX NOTICE) WORK PROPOSED CONSTR ADDIALT �� SIGN Q [ DEMOLISH INSTALL ElINSTALL8 REPAIR PROPOSED USE SFR COMM OTHER TYPE OF CONSTRUCTION BLOCK 0 FRAME STEEL DESCRIPTION OF WORK IITStallat6011 Of Pie solar panels On rooftop BUILDING; SIZE ®^ _ SO FOOTAGE j 4 HEIGHT BUILDING $ VALUATION OF TOTAL CONSTRUCTION ELECTRICAL $ AMP SERVICE PROGRESS ENERGY 90,432.00 PLUMBING $ = J'Oo =MECHANICAL $ VALUATION OF MECHANICAL INSTALLATION GAS ROOFING = SPECIALTY = OTHER FINISHED FLOOR ELEVATIONS � FLOOD ZONE AREA =YES NO �11 W.R.E.C. BUILDER COMPANY ;;;;;; SIGNATURE REGISTERED FEECURREN N Address License # E ^LLC ELECTRICIAN==REGISTERED Y E dom Forever FL Ftky ,SIGNATURE N FEECURREN Y° N Address License# EG1300S056 PLUMBER COMPANY ;;;. SIGNATURE REGISTERED F"E C.RRE ��;Y t N _ ._.-._._._= Address License # E:== MECHANICAL. � COMPANY SIGNATURE REGISTERED YIN FEE CURREN Y I N Address License # E==_ =._..--.._»._.= OTHER COMPANY SIGNATURE �j REGISTERED �;N F�CURREII Address License # *# Ito E1#t11111Ito III *AIII Ito ,1ff11111#III It#)III* I RESIDENTIAL Attach (2) Plot Plans; (2) sets of Building Plans; (1) set of Energy Forms; R-O-W Permit for new construction, Minimum ten (10) working days after submittal date. Required onsite, Construction Plans, Stormwater Plans wl Silt Fence installed, Sanitary Facilities & 1 dumpster; Site Work Permit for subdivisions/large projects COMMERCIAL Attach (2) complete sets of Budding Plans plus a Life Safety Page, (1) set of Energy Forms. R-O-W Permit for new construction. Minimum ten (10) working days after submittal date Required onsite, Construction Plans, Stormwater Plans wl Silt Fence installed, Sanitary Facilities & 1 oumpster. Site Work Permit for all new projects. All commercial requirements must meet compliance SIGN PERMIT Attach (2) sets of Engineered Plans. -PROPERTY SURVEY required for all NEW construction. Directions: Fill out application completely. Owner& Contractor sign back of application, notarized If over $2600, a Notice of Commencement is required, (A/C upgrades over $7500) *' Agent (for the contractor) or Power of Attorney (for the owner) would be someone with notarized letter from owner authorizing same OVER THE COUNTER PERMITTING (copy of contract required) Reroofs if shingles Sewers Service Upgrades AIC Fences (PlouSurvey/Footage) Driveways -Not over Counter if on public roadways..needs ROW DocuSign Envelope 1D: 38F73693-5BF6 4087 SE9Q-931QFD1A25E3 Y hjI1S Permit Application Fax-813-780-0021 Building Department NOTICE OF DEED RESTRICTIONS: The undersigned understands that this permit may be subject to "deed" restrictions" which may be more restrictive than County regulations. The undersigned assumes responsibility for compliance with any applicable deed restrictions. UNLICENSED CONTRACTORS AND CONTRACTOR RESPONSIBILiTIES`: If the owner has hired a contractor or contractors to undertake work, they maybe required to be licensed in accordance with state and local regulations, If the contractor is not licensed as required by law, both the owner and contractor may be cited for misdemeanor violation under state law_ If the owner or intended contractor are uncertain as to what licensing requirements may apply for the intended work, they are advised to contact the Pasco County Building Inspection Division —Licensing Section at 727.847- 8009, Furthermore, if the owner has hired a contractor or contractors, he is advised to have the contractors) sign portions of the "contractor Block" of this application for which they will be responsible. If you, as the owner sign as the contractor, that may be an indication that he is not property licensed and is not entitled to permitting privileges in Pasco County. TRANSPORTATION IMPACTIUTILITIES IMPACT AND RESOURCE RECOVERY FEES: The undersigned understands that Transportation Impact Fees and Recourse Recovery Fees may apply to the construction of new buildings, change of use in existing buildings, or expansion of existing buildings; as specified in Pasco County Ordinance number 89-07 and 90-07,as amended. The undersigned also understands, that such fees as may be due, will be identified at the time of permitting. it is further understood that Transportation impact Fees and Resource Recovery Fees must be paid prior to receiving a "certificate of occupancy" or final power release. if the project does not involve a certificate of occupancy or final power release, the fees must be paid prior to permit issuance. Furthermore, if Pasco County Water/Sewer Impact fees are due, they must be paid prior to permit issuance in accordance with applicable Pasco County ordinances. CONSTRUCTION LIEN LAW (Chapter 713, Florida Statutes, as amended): if valuation of work is $2,500,00 or more, I certify that I, the applicant, have been provided with a copy of the "Florida Construction Lien Law —Homeowner's Protection Guide" prepared by the Florida Department of Agriculture and Consumer Affairs. If the applicant is someone other than the "owner, i certify that i have obtained a copy of the above described document and promise in good faith to deliver it to the 'owner" prior to commencement. CONTRACTOWS/OWNER'S AFFIDAVIT: I certify that all the information in this application is accurate and that all work will be done in compliance with all applicable Taws regulating construction, zoning and land development Application is hereby made to obtain a permit to do work and installation as indicated. I certify that no work or installation has commenced prior to issuance of a permit and that all work will be performed to meet standards of all laws regulating construction, County and City codes; zoning regulations, and land development regulations in the jurisdiction. I also certify that i understand that the regulations of other government agencies may apply to the intended work, and that it is my responsibility to identify what actions I must take to be in compliance. Such agencies include but are not limited to Department of Environmental Protection -Cypress Bayheads, Wetland Areas and Environmentally Sensitive Lands, Water/Wastewater Treatment. Southwest Florida Water Management District -Wells, Cypress Bayheads, Wetland Areas, Altering Watercourses. Army Corps of Engineers -Seawalls, Docks, Navigable Waterways. - Department of Health & Rehabilitative Services/Environmental Health Unit -Wells, Wastewater Treatment, Septic Tanks. US Environmental Protection Agency -Asbestos abatement. Federal Aviation Authority -Runways. I understand that the following restrictions apply to the use of fill: Use of fill is not allowed in Flood Zone W" unless expressly permitted. If the fill material is to be used in Flood Zone "A" it is understood that a drainage plan addressing a "compensating volume" will be submitted at time of permitting which is prepared by professional engineer licensed by the State of Florida, If the fill material is to be used in Flood ;Zone "A" in connection with a permitted building using stem wall construction, I certify that fill will be used only to fill the area within the stem wall. If fill material is to be used in any area, I certify that use of such fill will not adversely affect adjacent properties. If use of fill is found to adversely affect adjacent properties, the owner may be cited for violating the conditions of the building permit issued under the attached permit application, for lots less than one (1) acre which are elevated by fill, an engineered drainage plan is required, If I am the AGENT FOR THE OWNER, I promise in good faith to inform the owner of the permitting conditions set forth in this affidavit prior to commencing construction. I understand that a separate permit may be required for electrical work, plumbing, signs, wells, pools, air conditioning, gas, or other installations not specifically included in the application. A permit issued shall be construed to be a license to proceed with the work and not as authority to violate, cancel alter, or set aside any provisions of the technical codes, nor shall issuance of a permit prevent the Building Official from thereafter requiring a correction of errors in plans, construction or violations of any codes. Every permit issued shall become invalid unless the work authorized by such permit is commenced within six months of permit issuance„ or if work authorized by the permit is suspended or abandoned for a period of six (6),months after the time the work is commenced. An extension may be requested, in writing, from the Building Official for a period not to exceed ninety (90) days and will demonstrate justifiable cause for the extension. If work ceases for ninety (90) consecutive days; the job is considered abandoned. WARNING TO OWNER: YOUR FAILURE TO RECORD -A NOTICE OF COMMENCEMENT MAY RESULT iN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY, IF YOU INTEND TO BTAIN FINANCING, CONSULT FLORIDA JURAT (F.S. 117.o3) OWNER OR AGENT CONTRACTOR Subscribed and sworn to (or affirmed) before me this S rib m o of me 's Who is/are personally known to me or has/have produced a Is are pinallyio n t me hash ve produce as identification, as dentificatlon. Notary Public Notary Public Commission No. Commission No.° Name of Notary typed, pr nted or stamped Name of Notary type printed or stamped 'NSTR#2024017042ORSK10952PG3011 -_. Nikki Alvarez-Sowles, Esq,, Pasco County Clerk & Comptroller THIS INSTRUMENT PREPARED BY: Name: Freedom Forever FL LLC Address: 2619 Consulate Drive Suite $00 Orlando F132819 Number:Permit ParcelIDNumber [`1walwlg flit',€Yr�7:aiTi►_ijiuo j���i * lw iFS%j[� # II'iJ Name and address. 1 c)titi 3 2 aJ r Interest in properly: peer Fee Simple Title Holder (if other than owner listed above) dame;_ Address: 4> CONTRACTOR, Name: Freedom Forever FL LLC Phone Number: 407-473-3938 Address: 2619 Consulate Drive Suite 800 Orlando F132819 6. SURETY (if applicable, a copy of the payment board is attached): Name: Address. Amount of Bond: 6. LENDER: Name: Phone Number: Address: 7Persons within the State of Florida Designated by Owner upon whom notice or other documents may be served as provided by Section Florida Name, Phone Number: 8. In addition, Owner designates of to receive a copy of the Lienors Notice as provided in Section 713.13(l)(b), Florida Statutes, Phone number: % Expiration Date of Notice of Commencement (The expiration is 1 year from date of recording unless a different date is specified) - � � M. A ' r A � .., �.. r 1. ♦ r 4 a � � � � " A. t •r..:.• w �'. r A r r.R � A a. +� t r �...r r OwWs or Lessee's' (r�nn Paa rr nd Provide S gnalr Y s FkuetCtf�cst i ArmwManaoer} State of Countye foregoing # zRx:a# before me by of #hysical presence or a #n this1 day of ! # - of person i.,. Fri #i who is personally # to me or has produced as iAa #: ,w ay .t SIERRA C OKAY nature of Notary Public �° • " Notary Public � stag of Florida �+ Commission 9 Hii 114656 ? r� My Cocain. Expires Apr 6.2025 Bonded through National Notary Assn. Dear Whom It May Concern, Proiect Name: JEFFREY LIDO, 38401 12TH AVENUE, ZEPHYRHILL S, FL 33542 Installation of a 5.36 kW (DC) Rooftop PV Solar System If you have any questions regarding this project, please feel free to contact me. O= Ricardo Pino, P.E. dcardop@ba1n11ncorp,cor-n 0 All/ Ns'...0 No� 91113 .74r STATE 0 F ORO NA1. 111111"O� .3,�,',,uur, Design,,,,),nd En,,gjineeiinq; t"""10 ',1C,",2J,' 06 RE: CERTIFICATION LETTER Project Address: JEFFEY LIND 112TH AVENUE ZEE HY HILLS, FL 33542 - Applicable Codes = 2023 FLBC/FLESC 8th Edition, 2023 FLRC 8th Edition, 2021 IEBC/IBC ASCE 7.22 and 2018 NDS - Risk Category = It - Wind Speed =145 mph, Exposure Category C, Partially/Fully Enclosed method - Ground Snow Load = 0 psf - Roof 1-3: 2 x 4 @ 24" OC, Roof DL = 7 psf, Roof t /SL =19 psf (Non-PV), Roof LL/SL µ 0 psf (PV) To Whom It May Concern, Existing roof structural framing has been reviewed for additional loading due to installation of Solar PV ,System on the roof, The structural review applies to the sections of roof that Is directly supporting the Solar PV System. Based on this evaluation, I certify that the alteration to the existing structure by installation of the Solar PV System meets the prescriptive compliance requirements of the applicable existing building and/or new building provisions adopted/referenced above, Additionally, the Solar PV System assembly (including attachment hardware) has been reviewed to be in accordance with the manufacturer's specifications and to meet and/or exceed the requirements set forth by the referenced codes. 4E ,,,G..,,v 11 ttl("'xy z Jto,fQ I i U o�",'�d ")u' pf ccr.wro .,nd' ",N,_ zt ,",t.w...,dt. „.r zii- t. ,m};I4, i 4:;.. ,E .o:.: i .,..�, rid. „v"i l t5i, ., { ,_ztf' 3' ...,. .., ,;ay .., Los't., ��, ., b l,., .. ., ... � o' nmo!e.�,. ,i"; o 3t B.§in_...b.o.jp Deskin 1,aS The e.k.ai..ng st, L1,:..m has s be...r ...,viev.tea0.a.,>.et on v" No la a: F,x been e>;'dd~;t P)O d?'-.'S g..a,,:..?... �,i , se`'.+te �. qt�'� 3pprc .)n.,,n, cadet 77he StructuralvnOQvW c# the. ,a at, ,t.7l opertyt , bame,d on, thep.a a, .ed ske $d, m aOki o-}?., t.ak .e lons,a ..edi.z.,W Aw Moo n. de ..,G.t. „<<°t; {p at .c.gii .,, *, d. Z`, ..,cttaYit= tt? ,e 1 ,is Satx, rU, t�F.. a.Ie i t. r.?a, ,.{c± e.;;f. All P1.-F`tdaYt3,4_s' r""v dt i. g wr?'ci i. t, a, 4'x i.€ eflt E;` h.pm,e>Pot .. d _ H be defgned and t „ix..?..e d per c'q�')wti ov P;.te,deff .e.'s , c. Ps"u . 0. a T,e}., . te"ii'. p j,"' f k.._, .o < ,a�tP { ?a 2.. �.z i a9...r ckf > "Iqe -": to Ow St"n ..st., al cc f, ,. . ?C,.t ",hot tvos not d "t,..i. ta' ii .ne.. Survey, F. 1cf t,. 4,.,t?' o' ,, Ple t s,i<t � 3, a in the a ,P}r..n'en? . t. ift' Om' {. t#tts ti i'{l � t)t2a• e=.ova as a", :>d_ e a7 4i ze .,tf' c,.,,wd e,io,,,. amd ,tf.� ,, rat { %;i Pit t?.�f not c. +to O`ue e,d, fFa'�icafior? #duty', sled r>orm ih t E.e a ew', t i,, Record xff ai ed dis(repancks poor to huralk"jon, , e et i. , w fit. da esg , mcKdParnly em t ,t... r;Je .r„ the E.tg we , a.4G d, U, v„S aif ,a def P.n .... Mile {,e re unknown Were not d&da, ndm We of sm vey o rt..t P, d4,,, omta,,-' . erChriz.ccl r this i,4` work.. Any in, ,t.e `,.'x.e c'f vvork .ha , ;o d �,e, ua .jch th o acld,:, .v"" ie "op o peg, in ad`vcP>,e tJaf 1 M w e� ed , bY DyMurt'r Rt, wfi, Bmtm Cum 4 E n wd P;.n:c,51f.>i. :�i 61RI,., 2Z ilc. 0 `6, 1 5.,.�. xs e,.T.�ta�;.,� P. �.'i3, _a ,t. 1 ya;`te i?...�, c,. �: ca , c.:.d.Pt i` i e /5 I REDUCED ROOF LIVE LOAD (Lr)_ Roof Live Load Member Tributary Area Roof 1-3 Pitch Tributary Area Reduction Factor Ground Snow Load Effective Roof Slope Snow Importance Factor Snow Exposure Factor Snow Thermal Factor 2.50 psf O50 psf PV-DL 3.00 Psi 150 psf 0,50 psf 1,50 psf 0.73 psf = 0.00 psf = 1.50 psf R-DL z 6.70 psf Lo = 20,00 psf At < 200 ft' 25' or 6/12 R1 = 1.00 R2 = 0,93 pg = O00 psf 25* Is = 1,00 Ce = 1,00 Ct = IAO pf-min = 0,00 psf Pf = OM psf Cs -roof = I �00 --m-roof = -Oxopsf B""m,,M C(,)r",) au,,d . . . . . . 611" ' 02,4,,"5(,)6 1 -J" ... . . .. .. . kj, 3 /5 EXISTING WITH PV PANELS Roof Dead Load (DL) = 6.70 9,70 psf Roof Live Load (Lr) = 1830 (LOO psf Roof Snow Load (SL) = UO UO psf EXISTING WITH PV PANELS (DL + Lr)/Cd = 20,16 10,78 psf (DL + SL)/Cd = 5A3 &43 psf Maximum Gravity Load = 20,15 10,78 psf Load Increase (%) ==iiOK The requirements of section 805.2 of 2021 IEBC are met and the structure is permitted to remain unaltered. 611(") 202AK,6 41,15 is Wind calculation is based can ASCE 7-22, 29.E § C C, LC 0: 061DL + 0,6WL is used, Lk.., .a Cot,p y �. and' st �,a..=�.- *�,i 610,202,45W,3 z , tO i{c-..q; ""omn CODES: CONSTRUCTION G: THIS PROJECT COMPLIES WITH THE FOLLOWING: 2023 8TH EDITION i FLORIDA BUILDING CODE CONDUIT DUIT AND CONDUCTOR SPECIFICATIONS ARE BASED ON MINIMUM CODE REQUIREMENTS AND 2023 8TH EDITION FLORIDA RESIDENTIAL CODE ARE NOT MEANT TO LIMIT UP -SIZING AS REQUIRED BY FIELD CONDITIONS. 2023 8TH EDITION FLORIDA MECHANICAL L CODE ALL SOLAR ENERGY SYSTEM EQUIPMENT SMALL BE SCREENED TO THE MAXIMUM UM EXTENT NO 00 E 2023 8T#-# EDITION FLORIDA PLUMBING G CODE POSSIBLE AND SHALL BE PAINTED A COLORSIMILAR TO THE SURFACE UPON WHICH THEY ARE s eE N 2023 8TH EDITION FLORIDA FUEL, GAS CODE MOUNTED. 2023 BTFI EDITI011! FLORIDA ENERGY GY CONSERVATION I CODEMODULES SMALL BE TESTED, LISTED AND INDENTIFIED WITH FIRE CLASSIFICATION IN =mar' " 2023 8TH EDITION FLORIDA EXISTING CODE ACCORDANCE WITH UL 2703. SMOKE AND CARBON! MONOXIDE ALARMS ARE REQUIRED PER No, 9111 2023 8TH EDITION FLORIDA ACCESSIBILITY CODE SECTION R314 AND 315 TO BE VERIFIED AND INSPECTED BY INSPECTOR IN THE FIELD. 2023TFf EDITION I FLORIDA FIRE PREVENTION #CODE 2017 NATIONAL ELECTRICAL CODE DIG ALERT (811) TO BE CONTACTED AND COMPLIANCE WITH EXCAVATION SAFETY PRIOR TO ANY AS ADOPTED BY CITY OF EPHYRHILLS EXCAVATION TAKING PLACE �o°.� TOTE F �•"lD � ��'� PHOTOVOLTAIC SYSTEM GROUND WILL BE TIED INTO EXISTING GROUND AT MAIN SERVICE FROM i ' ' ���� DO DISCONNECT/INVERTER A PER 017NEC SEC 250.16 (A), SOLAR PHOTOVOLTAIC SYSTEM EQUIPMENT WILL BE INSTALLED IN ACCORDANCE WITH REQUIREMENTS OF ART, 690 OF THE 2017 NEC VICINITY MAP- THE MAIN SERVICE PANEL WILL BE EQUIPPED WITH A GROUND ROC OR LIFER U ILITY COMPANY WILL BE NOTIFIED PRIOR TO ACTIVATION OF THE SOLAR PV SYSTEM h CLIENT: JEFFREY LIND INSTALL CREW TO VERIFY ROOF STRUCTURE PRIOR TO COMMENCING WORK. EMT CONDUIT 3840112TH AVENUE, ZE€ HYRHILLS, FL ; ATTACHED TO THE ROOF USING CONDUIT 11 OUNT 33542 AHJ CITY OF ZEPHYRHILLS UTILITY DUKE ENERGY METER 3563127 ART: 11-26-21-0010-€33500-€ 081 ` PHONE: 813 616-0412 E EMAIL: JEFFLINDI PORT T@GMAtL.COM THIS SYSTEM DESIGNED WITH: � � WIND SPEED: 145 0 # WIND EXPOSURE: C SYSTE�ti: SYSTEM SIZE (DC); €6 X 335 = 5.364 MN a 'SNOW LOAD: 0 SYSTEM SIZE (AC): 4.640 kW @ 240V MODULES: 16 X TRIM SOLAR: TSM-335 PE14A t 3 MICROINVERTERS` 16 X ENPHASE IQ8PLUS-72-2-US `✓% r. t , r S EXISTING SYSTEM, I % SYSTEM SIZE (DC):18 X 340 = 6,120 kW SYSTEM SIZE (AC): 4.320 P.ini @ 2401/ SITE LOCATION MODULES: 18 X Q CELLS Q.PEAK DUO BLK-G6+-340 TABLE CONTENTS:I7-60-z-€€SRr�RS: ,e X ENI�H�s� PV_1 SITE LOCATION REIiSiCiPtB PV-2 SITE PLAN L40. REVI DBY DATE PV-2A ROOF PLAN WITH MODULES LAYOUT - 1 - _...__.._ ._.._...__�_ PV-28 ARRAY AND STRUCTURAL TABLES PV-3 MOUNTING DETAILS PV 5 CONDUCTOR CALCULATIONS F o x k v ;l PV EQUIPMENT #P E# T c SERVICE LIST FREEDOM FOREVER LLC 2619 CONSULATE DR SUITE 800, ORLANDO, PV- LABELS FL 32819 Tet (80D) 385-1075 PV-7A SITE PLACARD GREGALBFtIG#-1T PV-8 MIC OINVE TER CHART PV SAFETY PLAN PV-10 SAFETY PLAN ONTRACTOR LICENSE: CERTIFIED ELECTRICAL CONTRACTOR APPENDIX MANUFACTURER SPECIFICATION SHEETS EC43008055 JOB NO: DATE: DESIGNED BY: SHEET: 4s03621 112712024 Y.J. PV-1. L Ei li : { } PV SYSTEM PV PV Y TE T.IIS SYSTEM DESIGNED WITH: TOTAL ROOF AREA RIDGE SETBACK CALLS: 6,120 kW -DC . 6 kW ­DC 11,4 kW -DC€ C. TOTAL ROOF AREA: 2294.22 C F 4.320 kW -AC 4. i4 k AG (kW -AC DEXPOSURE: SINGLE MODULEAREA: 20.92866048Q T s. ` CHIMNEY SOW LOAD: 0 TOTAL NUMBER OFMODULES: 16 _ TOTAL AREA OF MODULES: 334.86 SO FT `` ` PIPE VENTE FENCE ROOF COVERAGE: 14.6 �1�, ������ �.. FIRE SPRINKLERS: NO ATTACHMENTS PROPERTY LIME t' ' o. 1113 MODULES � _ RAFTERS r " (# 16 TRIiIA SO R: TStr-335 PE14A , 333 l Rp ROOF LINE a $ "� ��"4STATE OF RAIL " �JSETBACK � E'Asy ICBP#-7�2-iS 293Jail � .- e INVERTER NTH RAPID SHUTDOWN AC aC DISCONNECT � y_ n � cam MAID BREAKER c RISE ENCLOSURE ! � (N) E P ASE CONSIDER PANEL JUNCTION (I) LOAD CENTER ` < ROOF AREA: 2294,22 SQ FT BOX iI ITY 'O GENERATION DISCONNECT TCH oum U EATON DG222NRB (OR EQUIVALENT) d � CUEIdT. (E) ENPHASE COMBINER PANEL METER 6 J � JEFFREY LIND MICRO N JUNCTION BOX � i Li 5� 38401 12TH AVENUE, ZEPHYRHILLS. FL crc { } (E) AC DISCONNECT33542 INVERTER •-� . �� AHJ: CITY OF ZEPHYRHILLS COMBINER BII iER UTILITY: DUKE ENERGY i e METER:3563127 PANEL In. APN: 11-26-21-0010-03500-0081 FENCE/GATE PHONE; (813) 616-0412 L LOAD �� `:� a EMAIL: JEFFLINDIMPORTANTt@GMAIL.COM CENTER �_, (E) MAIN BREAKER ENCLOSURE --- """ — SYSTEM, e (E) UTILITY METER SYSTEM SIZE IDC):16 X 335 = 5.360 kW * SYSTEM SIZE (AC): 4.640 kW C 240V MODULES: 16 X Tf II 4 SOLAR: TSM-335 X PE14A MICR(E) 18 Q CELLS Q. PEAK DUO ELK-G6+ - 340, 340 1 IQ8PL S-72- TERs:1s x EIaPHASE ..-y-' rc�sPLu;�-72-z-uS 1 2 SIZE (DC): 18 X 340 = 6A 20 kW SIZE (AC): 4.32Q kW g 240V S: 18 X Q CELLS Q.PEAK DUO -340 VERTERS: 18 X ENPHASE :,; ,qfr FREEDOMFOREVER LLC 2619 CONSULATE DR SUITE NO, ORLANDO, FL 32819 Te#: {{8OD�7 385 1 175 GREG Fi( BRIG"HT � t CONTRACTOR LICENSE: CERTIFIED ELECTRICAL CONTRACTOR EG 1300805f SCALE2 25' - f� f . SITE PLAN=lBlYSHEET JC38Id{}: I>ATE_t?ESI403621 1127f2024: LEGEND: CHIMNEY PIPE VENT ATTACHMENTS ri u MODULES RAFTERS RAIL 01 SETBACK HAC DISCONNECT EdMAIN BREAKER ENCLOSURE HJUNCTION BOX UTILITY METER MICRO INVERTER COMBINER PANEL LOAD CENTER Ifp (E) PV SYSTEMT(N) PV SYSTEM (T) ITV SYSTEM THIS SYSTEM DESIGNED WITH: 6.120 kw-bc 15.360 kW -DC 111.480 kW-Dc�--- I I EED: 145 4.3:1! 3 14.640 18.960 kW -AC �j WIEXPOSURE: ND C SNOW LOAD: 0 (N) JUNCTION B (E) 18 0 CELLS Q.PEAK DUO BLK-G6+ - ROOF PLAN SCALE 1/811 = 11-o" ro TOTAL ROOF AREA: 2294.22 SO FT TOTAL ARRAY AREA: 334.86 SQ FT ARRAY COVERAGE: 29.35% SYSTEM DISTRIBUTED WEIGHT. 2.37 LBS ROCKIT SMART SLIDE POINT -LOAD- 31-75 S-72-2-US 290 W iASE COMBINER PANEL )CENTER 31SCONNECT J DG222NRB (OR EQUIVALENT) 4PHASE COMBINER PANEL AC DISCONNECT (E) MAIN BREAKER ENCLOSURE "E) UTILITY METER NOTES: 1. EMT CONDUIT ATTACHED TO THE ROOF USING CONDUIT MOUNTS 2. ATTACHED CLAMPS AT 25% FROM THE EDGE AND 50% FROM THE CENTER OF THE MODULES 3. JUNCTION BOX IS MOUNTED TO THE RAIL, AN NGo No.96636 s OF T F ROOF AREA. 2294,22 SO FT CLIENT: JEFFREY LIND 38401 12TH AVENUE, ZEPHYRHILLS, FL 33542 AHJ: CITY OF ZEPHYRHILLS UTILITY: DUKE ENERGY METER: 3563127 APN: 11-26-21-0010-03500-0081 PHONE: (813) 616-0412 EMAIL. JEFFUNDIMPORTANT@GMAIL.COM IYSTEW, SYSTEM SIZE (DC): 16 X 335 = 5360 kW SYSTEM SIZE (AC): 4.640 kW @ 240V MODULES: 16 X TRIVIA TSM-335 PE14A MICROINVERTERS: 16 X ENPHASE 108PLUS-72-2-US SYSTEM SIZE (DC): 18 X 340 = 6,120 kW SYSTEM SIZE (AC): 4,320 kW @ 240V MODULES: 18 X Q CELLS Q,PEAK DUO BLK-G6+ - 340 MICROINVERTERS: 18 X ENPHASE 107-60-2-US NO, I REVISED BY DATE ftedom- fREEDOM FOREVER LLC 2619 CONSULATE DR SUITE 800, ORLANDO, FL 32819 Tel: 385-1075 GROLBRIGHT j1\ CONTRACTOR LICENSE: CERTIFIED ELECTRICAL CONTRACTOR ECI 3008066 ROOF PLAN WITH MODULES LAYOUT 0 P' OE7 IGNED BY: SHEET: JOB NO; C NED �Sr.SHE -T 036 1 j PV-2A �4036201 ILIC2712024 K.J. PV 2A ROOF AREA STATEMENT JEFFREY LIND ROOF MODULE QUANTI ROOF PITCH ARRAY PITCH AZIMUTH ROOF AREA ARRAY AREA 33542 AHJ: CITY OF ZEPHYRHILLS METER: 3563127 SO FT SQ FT PE14A g&1STING SYSTEM SYSTEM SIZE (AC): 4.320 kW @ 240V ARRAY DETAILS JOB NO: I TE: SIGNED BY: TABLE 1 - ARRAY INSTALLATION ROOF ROOFING TYPE ATTACHMENT TYPE FRAMING TYPE MAX UNBRACED STRUCTURAL PENETRATION MAX ATTACHMENT MAX RAIL OVERHANG(I PITCH LENGTH(FT.) ANALYSIS RESULT PATTERN SPACING (IN.) N.) ECCIFASTEN ROCKIT SMART ROOF 1 25 COMP SHINGLE SLIDE 2x4 TRUSS@ 24" OCr 6 PASS STAGGERED 72" OC 24 ECOFASTEN ROCKIT SMART ROOF 25 COMP SHINGLE SLIDE 2x4 TRUSS@ 24" O.C. 6 PASS STAGGERED 72" OC 24 ECOFASTEN ROCKIT SMART ROOF 25 COMP SHINGLE SLIDE 2X4 TRUSS( 24" O.C. 6 PASS STAGGERED 72" OC 24 ------------ I --------- T- 1. CONTRACTOR TO VERIFY FRAMING TYPE AND MAX UNBRACED LENGTH PRIOR TO INSTALLATION. IF THE ABOVE INFORMATION DOES NOT MATCH FIELD CONDITIONS, NOTIFY ENGINEER OF RECORD IMMEDIATELY, 1 MAX RAIL OVERHANG APPLICABLE FOR RAILED ATTACHMENT INSTALLATIONS. I NT Scale. S A-KII mvUNl W MODULE fA ACID ENT DE.TAIL to NITS STACKED DETAIL For Illustration purposes tSTAGGERED DETAIL For illustration purposes only CLIENT: JEFFREY LIND 3WI 12TH AVENUE, ZEPHYRHILLS, FL 33542 AHJ: CITY OF ZEPHYRHILLS UTILITY: DUKE ENERGY METER: 3563127 APN: 11-26-21-0010-03SM-0081 PHONE: (813) 616-0412 EMAIL: JEFFLINDIMPORTANTB—GMAIL,COM IYSTEW SYSTEM SIZE (DC): 16 X 335 = 5,360 kW SYSTEM SIZE (AC); 4.640 kW @ 240V MODULES: 16 X TRINA SOLAR- TSM-335 PE14A MICROINVERTERS: 16 X ENPHASE 108PLUS-72-2-US EXISTING SYSTEM, SYSTEM SIZE (DO): 18 X 340 = 6,12014 SYSTEM SIZE (AC): 4,320 kW @ 240V MODULES: 18 X 0 CELLS Q. PEAK DUO f MODULE MODULES: - 340 MICROINVERTERS: 16 X ENPHASE 107-60-2-US FREEDOM FOREVER LLC 2619 CONSULATE DR SUITE 800, ORLANDO, FL 32819 Tel: - GRO21I.3051 GIORS CONTRACTOR LICENSE: CERTIFIED ELECTRICAL CONTRACTOR EC13MO56 MOUNTING DETAILS acal 1DATE: Y: ilG;NEDBY; �AFSHE!M I PV 3 443621 i 1/27/2024 K.J. PV-3 BACKFEED BREAKER SIZING fglpy SYSTEM (N) PV SYSTEMI IT) PV SYSTEM (TOTAL) MAX. CONTINUOUS OUTPUT 37.36A @ 240V 6.120 kW -DC 5.360 kit -EEC 11.480 kW -DC NEW 19.36 IX 1.25 = 24.2AV1P6 25A BREAKER - OK 4.320 kW -AC 4.646 kW -AC 18,9650 kW -AC fill, EXISTING 1&00 X 1.25 = 2 ;50AMPB 2 A BREAKER - OK '`I'k TOTAL 2420 r 22. f1 = 46.7A P6 150A BREAKER OK SEE 70512 OF 2017 NEC 150 1X 1.2o I = 1180 NO. 91113 180 - 1 150 1 = 130A ALLOWABLE BACKFEED 37.36 X I 47A PS 150A FUSES -OK STATE Ca F 4 fII CLIENT: JEFFREY LIND 38401 12TH AVENUE, ZEPHYRHILLS, FL (E)150A RATED fEl UTILITY METER 33542 MAINSERVICE P 9PH' 120d240VOOH7 as AHJ. CITY OF ZEPHYRHILLS UTILITY: DUKE ENERGY {Ei 153A d2F METER: 3563127 MAIN BREAKER - APN. 11-26-21-00'1 35{}"081 (TOP FED) PHONE: (813) 616-0412 EMAIL: JEFFLINDIMPORTANT@GNIAIL.COM BRANCH CABLES INTEGRAL TO INVERTERS 1 #6 AWG, BARE COPPER GROUND i s SYSTEM. r SYSTEM SIZE (DC): 16 X 335 = 5:360 kW ENPHASE IQ8PLUS-72-2-US,2W W _..-.-; r.-e a SYSTEM SIZE (AC)-: 4.640 kW @ 240V MCROIFdVERTERB MODULES: 16 X TRINA SOLAR: TSAR-335 PE14A ., N 60A FUSED fib X ENPHA5E STRING't. - GENERATION DISCONNECT 'j F QSP LUS- 2- US TFZ3NA SOLAR. TSh4.335 PE14A 335 W N - rc �.... 2-#BAWG, THWN-2 SkMTCH F LISTED CONNECTOR UL {hJ) ENPHASE 1 -#10 EGC, THWN-2 EATON DG222NRS (OR "; ? - - J €a TiOra=. COMBINER Box EQUIVALENTI � �-- SN 3f4" 6R LARGER EMT CCNtiUET WITH 5SA FUSES, E " ENPHASE IQ8PLLr-72-2-US 2W W - ' r (N) IOBA DEDICATED KMFEBLADE, LOCKABLE, NrEMA � w i ` LOAD CENTER 3R, UL LISTED MICROINVERTERs NEMA 3R STEMSIZE EXISTING S(DC): 18 X 340 = 6A20 kW tisane _ ( = TO UTILITY SYSTEM SIZE (AC): 4.320 kW @ 240V a}2oA f zP �--, auERIaEAD MODULES: 98 X Q CELLS Q:PEAK DUO f £ s s FEED EiLtC-G6+- 34C1 M_u _ 8 TRIPSJ4 SOLAR: T3M-'535 PEt4ft 335 . I ... MICROINVERTERS: 1$ X ENPI'£�SSE IQ7 6£A2-US IN) 20A 2P 3-#'AWG,THWN-2 3-#L#VVS,THWN-2 BRANCH CABLES INTEGRAL TO INVERTERS Es .,..- , 1 -#`:: EGO, THWN-2 IN 3W OR LARGER EMT CONDUIT REVISIONS 1 #9 AWG. BARE CLIPPER GROUND IN 314' OR LARGER EMT IN 15Ai 2P WC3 ( REVISEDSY DATE4-#10 AVYG.. THV'dN-2 CONDUIT 1 . #10 EGG. THWN-2 14 GATEWAY IN 3/4' EMT CONDUIT EXISTING CONDUIT ANDAIRE freedom (E) MODULESM QCELiS(EjAC .._a....- FREEDOM FOREVER LLC Q,PEAK DUODISCONNECT -- 2619 CONSULATE OR SUITE 800, ORLANDO, BLK-Gfi4-346 FL 32819 WATTS TeI: (800) 385-9075 18 34tiW DREG ALBRiGHT I i t s 20NTRAGTOR LICENSE; CERTIFIED ELECTRICAL CONTRACTOR EC13008056 NOTE: CONDUIT AND CONDUCTORS SPECIFICATIONS ARE BASED ON MINIMUM CODE REQUIREMENTS AND ARE NOT MEANT THREE LINE DIAGRAM TO LIMIT UP -SIZING AS REQUIRED BY FIELD CONDITIONS JOB O: . GATE: DESIGNED BY: SHEET: 403621 ..i127/2024. K.J. PV-4 RE SCHEDULE CE1t�lA'f EQUIPMENT CONDUCTORALLOVItABLE- QTY.AT1��'ACITY A RE SIZE STARTING 9f7°C 310.15(S}(16) STARTING CURRENT APPLIED TO CONDUCTORS IN RACEWAY TEMPERATURE CORRECTION FACTOR. 310:16(13}(2)(�) ADJUSTMENT FACTOR FOR FACTOR MORE THAN 3 CONDUCTORS 31OA5(8)(3)(a) ADJUSTED AMPACITY � 90°C MAXIMUM CURRENT APPLIED TO CONDUCTORS IN RACEWAY 1 2 3 4 DC AC AC AC MODULE MICROINVERTER JUNCTION BOX ENPHASE COMBINER PANEL TO TO T; TO MICROINVERTER JUNCTION BOX ENPHASE COMBINER PANEL LiEC71CATEIJ LOAD CENTER 2 2 4 3 10 19 10 8 40 40 40 55 I t% 9.68' 9.68 37 36 0.91 0 91 0.91 0.91 1 ' 1 0:8 1 36A0 36A0 29.'12 50:05 14.61 12.10 12A0 46.70 5 AC EXISTING INVERTER 1 TO DEDICATED LOAD CENTER 3 10 40 1&00 0,91 1 36A0 22.50 6 AC DEDICATED LOAD CENTER TO AC DISCONNECT 3 8 55 37.36 0,91 1 50.05 46.70 7 AC PC DISCONNECT TO POI 6 75 37.36 0;91 1 68.25 46:70 %A It, A. Noi 111 �$ STATEOF 401111D*� JEFF EY LIN€7 £11 12TH AVENUE, ZEPHYRHILLS, FL 33542 AHJ: C4TY OF ZEPH'YRHILLS UTILITY: DUKE ENERGY METER:3563127 ARK 11-26-21-001€3.03 sD 81 PHONE: (813) 616-0412 EMAIL: JEFFLINDiMPORTANT GMAIL,COM SIZE (DC): 16 X 335 = 5.360 kW SIZE (AC): 4,640 kW Q 240VV S: 16 X TRINA SOLAR: TSM-335 VERTERS: 16 X ENPHASE a2-2-US SYSTEM SIZE (DC): 18 X 340 = 6,124 kW SYSTEM SIZE (AC)j: 4.320 kW @ 240V MODULE& 18 X O CELLS Q.PEAK DUCT BL -G6+- 340 MICROINVERTERS: 18 X ENPHASE IQ7-60-2-US .�. 0 � � , FREEDOM FOREVER LLC 2619 CONSULATE DR SUITE 800, ORLANDO, Ft 32819 Tei; (8 ) 385.1075 DREG ALBRIGHT 3 �x CONTRACTOR LICENSE: CERTIFIED El ECiR€GAL CONTRACTOR EC13008056 CONDUCTOR AMPACITY CALCULATIONS IN ACCORDANCE WITH NEC 690.8. CONDUCTOR CALCULATIONS JOB NO: DATE: I DESIGNED BY: SHEET: 403621. 1/27/2024 K.J. PV-5 CITY. PART TART #- DESCRIPTION 16 MODULES PV 113-335S TRINA SOLAR: TSM-335 PE14A' 1 JUNCTION BOX RAC-260-049 60OVDC NEMA 3R UL LISTED JUNCTION BOX 1 MOULTING BRACKET RAC-211-201 UNIRAC E-BOSS J-BOX MOUNTING BRACKET 4 ELECTRICAL ACCESSORIES EA-350-326 STAUBLi tMULTI-CONTACT MG4 CONNECTOR (FEMALE) 4 EQUIPMENT ACCESSORIES EA•350I 327 STAUBLI I MULTI -CONTACT MC4 CONNECTORS (MALE) 16 INVERTERS INV-120-015 ENPHASE IQ6PLUS-72-2-US i MONITORING EQUIPMENT CIE-180-201-4C ENPHASE: COMBINER PANEL 4C 19 ELECTRICAL ACCESSORIES EA-160-I "ENPHASE, Q CABLE PORTRAIT FOR 60i72 CELL" 19 ELECTRICAL ACCESSORIES EA-160.105 "ENPHASE, Q CABLE LANDSCAPE 60 CELL" 1 MONITORING EQUIPMENT ME-180-201 "ENPHASE, AC COMBINER WT IQ GATEWAY PCBA, 80A, 240V' 1 WIRE WR-310-300 "ENPHASE, RAW TRUCK CABLE (300 FT, ROLL)" 128 ELECTRICAL ACCESSORIES EA-160-110 ENPHASE TIE WRAPS i CABLE CLIPS 4 2 ELECTRICAL ACCESSORIES ELECTRICAL ACCESSORIES EA-160-107 EA-160-109 ENPHASE SEALING CAPS FOR Q CABLE ENPHASE TERMINATOR 1 LOAD CENTERSIMAIN PANELS EE-151-109 100A DEDICATED LOAD CENTER I DISCONNECTS EE-321-061 60A RATED 240VAC NEMA 3R UL LISTED 2 FUSES BR-330-050 50A FUSE 1 PH 240VAC 3 25 ELECTRICAL ACCESSORIES FITTINGS/ANCHORS EA-350-113 ` RAC-265-034 IDEAL B-TAP 410-10 AWG ROCKIT SMART SLIDE 27 FOOTINGS RAC-265-004 "MFG: BOO FASTEN, ROCKIT COMP COUPLING AL BLK, MFG SKU, 2011021"' 25 FOOTINGS RAC-265-001 'MFG: EGO FASTEN, GF-1 FLASHING GLV ELK 8XIG-, MFG SKU: 3012029' FOOTINGS FITTINGS/ANCHORS RAC-265-028 RAG-265-031 'MFG: ECO FASTEN, SKIRT AL BLK 35MM & 40MM A80, MFG SKU: 2€19901Z' "MFG: BOO FASTEN, SKIRT END CAP PLS 35MM&40M€ih-A, MFG SKU: 2099035" 16 RAILS RAG-265-018 "MFG: ECO FASTEN, FRAME MLPE MOUNT SS, MFG SKU: 4011012'° 50 SCREW RAC-265-035 ROCKIT SCREW #12X3 tir ox KK ¢ O. 9111 '4 STATE OF JEFFREY LIND 3MI 12TH AVENUE, ZEPHYRHILLS, FL 33542 AHJ: CITY OF ZEPHYRHILLS UTILITY DUKE ENERGY METER. 3563127 APN: 11-26-21-00I M3500-0081 PHONE: (813) 616-0412 EMAIU JEFFLINDIMPORTAIiT@GMAIL.CO ZE (DC): 16 X 335 m 5,360 kW ZE (AC): 4,640 kW @ 240V 16 X TRIM SOLAR: TWA-335 :RTERS: 16 X ENPHASE `.-2-US SYSTEM SIZE (DC): 18 X 340 =6A20 kW SYSTEM SIZE (AC): 4.320 kW a;240V MODULES: 18 X 0 CELLS Q:PEAK DUCT BLK-G6+ - 340 MICROINVERTERS:18 X ENP14ASE NO _._., REVISED BY DATE E f Jfreedom ecxguc, 9..- FREEDOM FOREVER LLC 2619 CONSULATE DR SUITE 800, ORLANDO, FL 32819 Ter: (80) 385-1075 DREG ALBRIGHT CONTRACTOR LICENSE: CERTIFIED ELECTRICAL CONTRACTOR EC13008056 EQUIPMENTTj °B' SERVICE LIST d 036 1 112D72024 I ESi K NJ L7 BY�SPV_6 : 43 ,5f5(c)(3) C RAPIDTURN POSITION TO SHUT DOWN SWITCH TO THE "OFF" I OPTIONAL------------------------- LA LOAD CENTER (UNLESS BUSBAR IS FULLY RAT] 705.12(C)(2) i JEFFREY LIND 38401 12TH AVENUE, ZEPHYRHILLS, FL 33542 AHJ: CITY OF ZEPHYRHILLS UTILITY: DUKE ENERGY METER: 3563127 APNF 11-26-21-0€IM3 81 PHONE: (813) 616-0412 EMAIL: JEFFLiNDIMP RTANT GMIAIL.COM (GC): 16 X 335 = 5.360 kW (AG): 4.640 kW @ 240V X TRINA SOLAR: TSM-335 "EELS; 16 X ENP€iASE EXISTING SYSTEW SYSTEM SIZE (DC): 18 X 340 = 6.120 kVA.' SYSTEM SIZE (AC): 4,320 kW @ 240V MODULES: 18 X Q CELLS Q,PEAK DUO BLK-G6+-340 MICROINVERTERS: 18 X ENPHASE freedom - FREEDOM FOREVER LLC 2619 CONSULATE DR SUITE,800, ORLANDO, FL 32819 Tel: (800) 385.1075 GREGALBRIGHT c Ei) I CONTRACTOR LICENSE: CERTIFIES} ELECTRICAL CONTRACTOR EC13 O56 Lm;{ [c� z'5 LABELS -- E JOB NO: I DATE: I DESIGNED BY: SHEET: NFPA 11.12.2.1.1.1.1 1 „ EVERY 1 VON CONDUIT AND ENCLOSURES 403621 .1/27/2024 K.J. I PV-7 JUNCTION TION BOX , () 18 PV MODULES (N) 16 MICRO INVERTER (N) 16 PV MODULES (N) COMBINER BOX (N) LOAD CENTER (N) GENERATION DISCONNECT SWITCH (E) COMBINER BOX n"I((") AC DISCONNECT MAIN BREAKER ENCLOSUREUTILITY METER WARNING, DISCONNECTTURN OFF PHOTOVOLTAIC AC 1NEC ARTICLES 690 AND 705 AND IRC SECTION R324 MARKINGS SHOWN HEREON. 2. ALL MARKING SHALL CONSIST OF THE FOLLOWING k UV RESISTANT SIGN MATERIAL NTH ENGRAVED OR MACHINE PRINTED LETTERS OR } B. RED BACKGROUND COLOR APPROPRIATELYC. AERIAL FONT. 3. ALL SIGNS SHALL BE SIZED • ; we I 0 V4 Z No. 91113 m m�a z % STATE 0 F � rN 111111 CLIENT: JEFFREY LIND 38401 12TH AVENUE, ZEPHYRHILLS, FL 33642 AHJ: CITY OF ZEPHYRHILLS UTILITY. DUKE ENERGY METER;3563127 APN: 11-26-21-001 M3500-0081 PHONE: (813) 616-0412 ENTAIL: JEFFLINDIMPORTANT Gk1AIL.COM ZE (DC): 16 X 335 = 5.360 kW ZE (AC); 4.640 kW @ 240V 16 X TRINA SOLAR TSW335 SYSTEM SIZE (DC): 18 X 340 = 6,120 kW SYSTEM SIZE (AC): 4.320 kW Q 240%1 MODULES: 18 X Q CELLS CREAK DUO BLK-G6+ - 340 MICROINVERTERS:18 X ENPHASE 107-60-2-US NOi REVISED BY DATE FREEDOM FOREVER LLC 2619 CONSULATE DID SUITE 800, ORLANDO, FL 32819 Tel: (800) 385-1075 GREGALSRIGHT Ic Cc NTRACTOR LICENSE: CERTIFIED ELECTRICAL CONTRACTOR EC13008056 d 11E1WsT 3 BY. SHEET: 403621 1121,2124 K.J. PV-7A ® 1- E .. l 4 CLIENT: ;' JEFFREY LIND �� 0 38401 12TH AVENUE, ZEPHYRHILLS, FL 33542 , AHJ: CITY OF ZEPHYRHILLS UTILITY: DUKE ENERGY 11 METER: 3563127 APN:11-26-21-0010-03500-0081 PHONE: ($13) 616 (1472 °� EMAIL: JEFFLlNDlMPORTANT@GMAlL.COM \C SYSTEM: pC SYSTEM SIZE {DC}: 16 X 335 = 5.360 kW . SYSTEM SIZE {AC}: 4.640 kW @ 240V MODULES: 16 X TRINA SOLAR: TSM-335 1 PE14A NG MICROINVERTERS. 16 X ENPHASE IQ8PLUS-72-2-US 12 } EXISTING SYSTEM: SYSTEM SIZE {DC}: 18 X 340 = 6.120 kW SYSTEM SIZE (AC): 4.320 kW @ 240V 13 MODULES: 18 X Q CELLS Q.PEAK DUO i BLK-G6+-340 MICROINVERTERS: 18 X ENPHASE 1`+ ; 1 iQ7-60-2-US �° �, REVISIONS NO. _ REVISED BY DATE 16 �gfreedomFREEDOM FOREVER LLC 2619 CONSULATE DR SUITE 800, ORLANDO, FL 32819 Tel: (800) 385-1075 17 DREG ALBRIGHT ' z` ..... 18 CONTRACTOR LICENSE: CERTIFIED ELECTRICAL CONTRACTOR EC13008056 1 MICROINVERTER CHART 20 JOB NO: DATE: DESIGNED BY: SHEET: 403621 1/27/2024 K.J. PV-8 JOB HAZARD ANALYSIS Crew leader to fill out all sections below, hold a pre -job safety meeting with all personnel, and upload this completed document and the Safety Plan to Site Capture Ladder Access Ladders must be inspected before each use. Extension ladders must be set up on a firm and level surface at a 4-to-1 rise to run angle (or 75 degrees) and the top must be secured to the structure. Extension style ladders placed on uneven, loose or slippery surfaces must additionally have the base firmly anchored or lashed so the base will not slip out. Extension ladders must be used with walk-through devices or the ladder must extend 36" above the stepping off point. A -frame ladders must only be climbed with the ladder spreader bars locked in the open position; A -frame ladders shall not be climbed while in the closed position (ex, closed and used while leaned against a structure). it notes: Mobile Equipment • Only Qualified operators will operate equipment; operators must maintain a certification on their person for the equipment being operated. • Type(s) of mobile equipment (Type/Make/Model): Crew leader responsible for communication with the client: 1 Heat Related fitness Prevention NOTE ADDITIONAL HAZARDS NOT ADDRESSED ABOVE ® Employees shall have access to potable drinking water that is (add as many as necessary by using additional sheets) Client and public is excluded from work area by barricades (N/A, fresh, pure, and suitably cool. The water shall be located as Define the Hazard: Method/steps to prevent incident: Yes, No): close as practicable to the areas where employees are working. Water shall be supplied in sufficient quantity at the beginning of Training and Pre -Job Safety Briefing the work shift to provide at least one quart per employee per ® All employees onsite shall be made aware of the specific hazards hour for drinking for the entire shift. Employees may begin the of this project and review this HJA during a pre -job briefing, and shift with smaller quantities of water if they identify the location Define the Hazard: Method/steps to prevent incident: their signature indicates awareness of site conditions and the and have effective means for replenishment during the shift to plan to eliminate any hazards identified prior to and during the allow employees to drink on quart or more per hour. The project. frequent drinking of water shall be encouraged. 0 Shade shall be present when temperature exceeds 80 degrees • Crew leader (name/title): Fahrenheit, When the outdoor temperature in the work exceeds Define the Hazard: Method/steps to prevent incident: 80 degrees Fahrenheit, employees shall have and maintain one • Crew member (name/title): or more areas with shade at all times. - New employees must be acclimatized. New employees will be • Crew member (name/title): monitored by their Crew Leader (site supervisor) for the first two (2) weeks of employment or longer when necessary. Define the I to prevent incident- • Crew member (name/title): e Employees will be allowed and encouraged to implement Crew member (name/title): cool -down breaks in the shade any time they feet the need to do Qualified operator(s): 1 so to protect them from overheating. Supervisors are Crew member (name/title): -1 REQUIRED to allow employees any break period they need Material Handling and Storage I I during high heat conditions. JEFFRECLIENT: Y LIND Materials will be staged/stored in a way that does not present a Airborne Contaminants: a Cool Vests are encouraged for all employees at all times during 38401 12TH AVENUE, ZEPHYRHILLS, FL hazard to client, personnel or public. Materials stored on the 0 Asbestos -containing (Transits) piping (ACP) - Do not disturb periods of high heat. 33542 roof will be physically protect from failing or sliding off. (move, drift, cut fracture, etc,) a Identify the location of the closet Occupational/industrial Clinic AHJ: UTILICITY OF ZEPHYRHILLS TY: DUKE ENERGY 0 Asbestos -containing thermal insulation (ACI) and or Hospital in case a crew member becomes ill. METER: 3563127 Fall Protection • A site -specific plan for fall prevention and protection is required prior to starting work and must remain onsite at all times until work is complete; a fall rescue plan must be outlined and discussed among the crew prior to work start. • First -person -Up (FPU) must install their anchor and connect before any other task, including installing other anchors. The Last -Person -Down (LPD) must be the only person on a roof uninstalling fall protection, 0 FPCP (name and title): 0 FPU and LPD (name and title): Electrical Safety • The Electrical Qualified Person (EQP) is required onsite to perform electrical work. • All electrical work will be performed with equipment in an electrically safe condition (de -energized) unless approval has been granted prior to work. • Service drops and overhead electrical hazards will be indentified and protected from contact, as neccessary. EQP (name and tile): Public Protection The safety of the Client and Public must be maintained at all times. The Client and the Public shall be prevented from entering the work zone through the use of barriers and/or signage, as required, Company, Client and Public property shall be protected from falling objects. Pets (including dogs) shall be secured by their owners prior to work start. The Client should not leave pets, family members, or others in charge or care of Employees, Contractors, or Temporary Workers. Asbestos -containing duct wrapping (ACW) - do not disturb, no attic or crawlspace access is allowed if work to be performed could cause exposure to personnel, client or public. 0 If yes, list specific tasks and protection in place: Weather and Environment The site supervisor shall forecast the weather conditions at the job site, prior to crew arrival, in order to mitigate any hazards associated with inclement weather (heat, cold, wind, rain, etc.) The site supervisor will utilized a portable wind meter (anemometer) to verify actual onsite wind conditions, by checking at the ground and on any elevated work surface (ex, rooftop) prior to work start, at midday and prior to solar panel staging on a roof. Elevated work involving the moving or maneuvering of solar panels shall cease at 25mph (sustained wind) until wind subsides. Forecasted weather maximum temp (degrees f): �?.Il eMDlovees on site? • If offsite replenish is necessary, where will you go to replenish water (location/address): • Who will replenish the drinking water (name): Restroom facilities Employees shall have access to restroorn facilities with hand -washing stations. Use of onsite restroorn is at the client's discretion (location is annotated below). If client does not give permission, location of suitable restroom facilities with hand -washing stations offsite will be provided. The onsite supervisor will identify location and make arrangements to ensure all employees have access at any point. Restro m facilities will be (circle one): Onsite - Offsite If Offsi te, add location name and address: Incident Reporting Procedure Contact your Site Supervisor Name: Contact your Manager Name: Phone: Contact your Site Supervisor Name: Phone: W1777TIr"11"lairie, Ilmorie n#rTI er, o uun escI Ipilun of what happen and when. Mono Multi Solutions THE 'y A' R, FRAMED 72-CELL MODULE (150OV) 7, -2- Comprehensive Products And System Certificates L pa 'K Tr i n ass o.-. I a r Idea! for large, scale installations One of the andustry's most trusted modules Highly reliable due to stringent quality control xi Certified to withstand the most challenging environmental condit'lons M Ax. (_• -0 jF PRODUCTS P01.1i RANGE T "t-LCTRiCAL DATA f,)W SM-PE'114A 320-34 Peak Power War:ts-P­(Wp)* 220 325 330 335 340 MeXiMUM Power Valtage-Vo-, (V) Open Circuit Voltags -vo( (V) Modu[e Efficiency n,, (P,) iG.5 S7C 1—t—ce IGO UN/-1,CN 'F­,' mlorc' , - 3d, 462 172 ITS E t Rt'Ai DA-FA (iC)" Maximum Power-P,,r, Ard 237 241 245 249 252 4 09x 4 Maximum Power Current-I,,r,., (A) 6.92 700 TOP 7.14 7,21 rn. - Open Ch VolrageAP, (V) 42,1 4Z2 424 42,6 4CEr ----------- - - Short Crack Current-Ir. (A) 739 7,42 7,49 7,55 7,60 ---------- 40/1.57 992ORIJ MECHHAIPOCAI DATA Back V" Solar Ceils.. Ki[ticrystalline 156,75 x 156,75 mm (6 Inches) Ll 1,2. 4� - -- -------- Coll 06entation 72 calls (6, - 12) 7c' Module, Dimensions 1960 - 992 x 40 men (772 r1 1.57 inches) ass Weight 225 kg (49,5 t1s) Glass 32 rnTr (0,13 inches), High Transmission, AR Coated Tempered Glass Backsheet White Frame Silver Anodized AbInniniurn Alloy 'A -A j-8ox IP67or 11PES rated Cables Photovoltaic Technology Cable 40mm? (0,006inches`), �-VCURVES OF V M01:,1`,_i-1E(3a5d!) 1200 rnm (472 inches,, connector Trina TS4 FireType Type I or Type 2 T ',A' 65 Er4PERAT`rjhF R , IN,/ MAYIMUM RAT 11,oGS L 44'C(t2'C) Operational Temperature 40-85°C "1 3f,....40 C,41ya/1C Max i mum, System Vo "tage 5(yGV DC {lE} P A CURVES OF PV 40Db1LEf335eiO TemperatufPCoeffident of Vo- -0.32'ser"C 1500V CIE (UL) Temperature Coefficreert of fo: Max Sends use Rating 15A vj A R R A N T Y PACKAGRIJIGCOIN' GURA� 1i year Product Workmanship Warranty Modules per box: 27 pieces 25 year Linear Power Warranty Modules pe r 49 container 648 Ideces (Plean, c.e. ­­ . —, ri, Y C/oj T ION READ SA F E T Y AND'NS7 ALLA I ION INS TRU C IONS Bat ORE jSING THE PRODUCT. ina1, Q 2017 Trine Spar UmInd. AI r3h5 reserved 5 bec if -at o ns icuded I n tnis data5heirT are subject to char ig e Wthout notice. Version numberTS1EN-?018,,B ....trirasolar.com CIENPHASE OEM IQ8 and IQ8+ Microinverters .1/ Our newest 108 Microinverters are the industry's first microgrid-forming, software defined microinverters with split -phase power conversion capability to convert DC power to AC power efficiently. The brain of the semiconductor -based microinverter is our proprietary application specific integrated circuit (ASIC) which enables the microinverter to operate in grid -tied or off -grid modes. This chip is built in advanced 55nm technology with high speed digital logic and has superfast response times to changing loads and grid events, alleviating constraints on battery sizing for home energy systems. Part of the Enphase Energy System, IQ8 Series Microinverters integrate with the 10 Battery, IQ Gateway, and the Enphase Apo monitoring and analysis software. Connect PV modules quickly and easily to IQ8 Series Microinverters using the included Q-DCC-2 adapter cable with plug-n-play MC4 connectors. when installed with 10 System Controller 2, meets UL 1741, and 108P]us support split -phase, 240V installations only. IQ8 Series Microinverters redefine reliability standards with more than one million cumulative hours of power -on testing, enabling an industry -leading limited warranty of up to 25 years, 'S? 108 Series Microinverters are UL listed as PV Rapid Shutdown Equipment and conform with various regulations, when installed according to manufacturer's instructions. Easy to install Lightweight and compact with plug-n- play connectors Power Line Communication (PLC) between components Faster installation with simple two -wire cabling High productivity and reliability Produce power even when the grid is down* More than one million cumulative hours of testing Class It double -insulated enclosure Optimized for the latest high-powered PV modules Microgrid-forming Complies with the latest advanced grid support — Remote automatic updates for the latest grid requirements Configurable to support a wide range of grid profiles Meets CA Rule 21 (UL 1741-SA) and IEEE 1547:2018 (UL 1741-SB 311 Ed,) Not.: IQ8 Microinverters cannot be mixed together with previous generations of Enphase microinverters 007 sehes, 106 series, etc) in the same system. 9 2022 Enphase Energy. All rights reserved. Enishase, the Enphase logo, 108 Microinverters, and other names are trademarks of Enphase Energy, Inc- Data subject to change. lQ8SP-12A-DS-0067-03-EN-US-2022-12-27 Commonly used module pairings! w 235-350 235-440 Module compatibility 60-cell / 120 half -cell 54-cell 108 half -cell, 60-cell / 120 half -cell, 66-cell l 132 half - cell and 72-cell / 144 half -cell MPPT voltage range v 27-37 27-45 Operating range V 16-48 16-58 Min- / Max. start voltage v 22/48 22/58 Max. input DO voltage V 50 60 Max. continuous input DO current A 10 12 Max. input DO short-circuit current A 25 Max. module 1,, A 20 Overvoltage class DO port it DO port backfeed current mA 0 PV array configuration 1 x 1 Ungrounded array; No additional DO side protection required; AC side protection requires max 20A per branch circuit Peak output power VA 245 300 Max. continuous output power VA 240 290 Nominal (E-L) voltage/ range' V 240 / 211- 264 Max. continuous output current A to t21 Nominal frequency Hz 60 Extended frequency range fix 47-68 AD short circuit fault current over 2 3 cycles Arms Max. units per 20 A (L-L) branch circuit' 16 13 Total harmonic distortion a5% Overvoltage class AC port III AC port backfeed current mA 30 Power factor setting to Grid -tied power factor (adjustable) 0.85 leading - 0,85 lagging Peak efficiency % 97.7 CEO weighted efficiency % 97 Night-time power consumption mw 60 Ambient temperature range -40*C to -6TC (-4TF to 140'F) Relative humidity range 4% to 100% (condensing) DO Connector type MC4 Dimensions (H x W x D) 212 mm (8.3") x 175 mm (6.9") x 30.2 min (1.2") Weight 1.08 kg (2.38 lbs) Cooling Natural convection - no fans Approved for wet locations Yes Pollution degree PD3 Enclosure Class II double -insulated, corrosion resistant polymeric enclosure Environ. category / UV exposure rating NEMA Type 6 / outdoor Certifications Rule 64-218 Rapid Shutdown of Joy Systems, for AC and DO conductors, when installed according to manufacturer's instructions, 11) P.,nrq Far mcd.4ewertFs wattage ab­stJh.h­t,,,.y ­Wt In additional dipong losses.seathecompatibifity calculator at t27 Nominal voltage tangs can be extended beyond nominal ii required by the utlliy (3}�imks may vary. Referto loom reaui:emenYs to deNne tPie number of microinverters per branch rn your area. 108SP-12A-DS-0067-03-EN-US-2022-12-27 Eaton DG222NRB Product LengtioDepth Product Height 7.35 in 14.37 in EAt&T*N Product 'Pseight Product Width Powering Strsiness Wor0wide 8.4 in 10 lb Warranty Certifications Eaton Selling Policy 25-000, one (1) year UL Listed from the date of installation of the Catalog Notes Product or eighteen (18) months from the date of shipment of the Product, Maximum hp ratings apply only when whichever occurs first. dual element fuses are used. 3-Phase no rating shown is a grounded B phase rating, UL listed. Enclosure material Fuse class provision Painted galvanized steel Class H fuses Fuse configuration Voltage rating Fusible with neutral 240V Number Of Poles Two -pole Number of wires 3 Product Category General duty safety switch Type General duty, cartridge fused Catalogs Eaton's Volume 2—Commema' Distnioution Multimedia Double Up on Safety Sn itching Devices Flex Center Specifications and datasheets Eator, Specification Sheet - DG222NRB Eaton Corporation pic Eaton House 30 Pembroke Road Eaton is a registered trademark. Dublin 4, Ireland FEaton.com All other trademarks are 0 C1 13 to A,i&TN 2023 Eaton. All Rights property of their respective Po,,wiag Hccpyw, wn 4tdwds Reserved. owners. Eaton. com/socialmed ia Listed 486B Pressure Cable Connectors File No. E-6238 Suitable for use on the line BW side of the service equipment. INSULATION -PIERCING TAP CONNECTORS Installation Instructions: Improperly installed electrical wiring can be dangerous and cause electrical fires. The connector chosen must be sized to the wires being used. Consult local building code before doing any electrical work. For assistance, refer to an instructional book or consult a qualified electrician. Contact With electricity can cause serious injury or death. Use on insulated cable only. [131-11-1, RHW(-2), THHN, THHW, THOU, THWN, USE, XHHW(-2). Consult factory for other insulation types]. If the installation is to be made on an energized run, the tap conductor must be under no load and must not be grounded. Use electrically insulated gloves. De -energize the run cable if there are any questions of these conditions being met. 1, Determine the direction for the tap conductor to exit and discard one end cap. See figure 1. 2. Position the main (or feeder) side of the connector around the run cable and tighten the bolt finger tight. See figure 2. If required, loosen the bolt slightly to allow the connector to open completely, DISASSEMBLY NOT RECOMMENDED. The plastic "Turbo' spacer holds the connector open which eases installation and ensures proper connections. 3. Cut the end of the tap cable squarely. DO NOT STRIP CABLE INSULATION, 4. Insert the tap cable into the tap side of the connector until it is seated in the remaining end cap. See figure 3. 5, Continue tightening the torque regulating bolt with a standard box or socket wrench until the torque regulating piece breaks away. If the connector has two (2) assembly bolls, alternately tighten until the hexagonal torque devices break away. See figures 4a & 4b. Note that the plastic "turbo" spacer on the side will also break. To make the installation even easier and to relieve torque from the cables, a second wrench can be used on the hexagonal piece on the bottom of the connector. DO NOT use gripping type pliers, pipe, open ended or adjustable wrenches as these may damage the hexagonal torque regulating device. A torque wrench is not required. MAKE SURE ONLY THE TOP HEXAGONAL TORQUE DEVICE OF THE BOLT HEAD IS USED FOR ASSEMBLY. THE SECOND HEX PIECE [CLOSER TO THE BODY OF THE CONNECTOR] IS USED FOR DISASSEMBLY. Note: The torque regulating bolt ensures the correct torque is applied to the conductors without using a torque wrench. Important information such as run and tap ranges, voltage ratings and material/temperature ratings is marked on the connector. 11 ffilw1m, WIS NMI N Los cables ortIctocos mat instalades pueden set peligrosos y provocar incendios. Ef conector escogirdo debe ser de on tarnabo adecuado para los cables que se utilicen. Consulte Jos c6digos de construction locales antes de efectuar trabajos electhcos. Si necesita ayuda, consulte on libm de instrucclones o consults con on electricista capacitado. Use solo an cable aislado. [RHH, RHW(-2), THHN, THHW, THW, THWN, USE, XHHW(-2). Censure cop is fdbrica para optener informaictin score otros tipos de aislamientol. Si se va a hacer la instalaci6n sabre un cable con coriente el conductor derivado dethe ester fibre de carga y no dabs estar aterado. Use guantes con a'slarniento ebictrico. Quite le la corriente ai cable del cual se hace la derivation si nose pueden cumplir estas condiciones. El contacto con electrichad suede producir asiones graves o mortales. 1. Determine la direccibn en la qua el conductor derivado saldrd y desedhe-la tape terminal sobrante. Vea [a ifustraci6n 1. 2, Coloque el lado principal (o de alimentacil5n) del corrector alrededor del coal se hace [a derivaci6n y apriete firmemente el dedo del perno. Vea la ifustracidn 2. Si hace falta, aftole el perno ligeramente para permitir que el conector se abra figure 2 completamente. NO ES RECOMENDABLE DESARMAR EL CONECTOR. El espaciador "Turbo" de plastico mantiene al conector abierto, to cual facilita [a instalacon y asegura quo bs conexiones se pagan correctamente. 3. Corte at extreme del cable de derivaci6n perpendicularmente a su pie. NO PELF EL AISLAMIENTO DEL CABLE. 4. Insede at cable de derivaci6n en el lado de derivacitin del conector pasta que tope contra [a tape terminal que queda. Vera la ifustracidn 3. 5, Continu6 apretando este perno que regula la torsion con una Ilave estAndar o de cubo pasta que la pieza qua regula la torsion se party y se separe. Si at conector Ilene dos (2) berries de ensamblaje, aprietelos alternativamente pasta qua el dispostivo de regulacibn de torpid se parta. Vea to flustraci6n 4a y 4b. Observe que of espaciador "turbo" de plastico an el costado figure 3 tambi6n se fracturara. Para hacer esta instalaci6n a6m mas fAcil y para aliviar la torsion be Joe cables, se puede user una segunda have score la pieza hexagonal at fondo, del conector. NO USE alicates de presibri, Haves de turbo, Haves comunes o ajustables ya que 6stas pueden datlar el dispositivo hexagonal que regula la torsion. No se requiere una I lave de torsion. ASEG6RESE QUIE SE USE, PARA EL ENSAMBILADO, SOLO EL DISPOSITIVO SUPERIOR DE REGULACION DE TORSION DE LA CABEZA DEL PERNO, LA SEGUNDA Beforer PIEZA HEXAGONAL (LA MAS CERCANA AL CUERPO Torque Torilue Readied, DEL CONECTOR) SE USA SOLO PARA DESARMIAR EL Applied One Hex Piece CONECTOR. Breaks -Away Nota: El perno regulador de torsion garantiza la aplicaci6n de la Lfigure L---i Lfigure L----J torsion correcta a los conductores sin usar una !lave de torsion. La informaci6n importante de longitud de cable potable y de toma, [as clasificaciones de materiales y temperatura est6 marcada en el conector. B-TAP@ INSULATION PIERCING TAP CONNECTORS TORQUE AND RRENT RATI (Solid and/or Stranded) NOMINAL TAP CURRENT RATIING CATALOG# MAIN TAP TORQUE (IN AMPS)- BTC2/0-14 2/0-4 10-14- 80 IN. LBS. 40 BTC1/0-10 1/0-8 2-10- 80 IN. LBS. 130 BTC4/0-10 4/0-3 2-10— 125 IN. LBS, 130 BTC4/0-6 4/0-2 1/0-6 160 K LBS. 170 BTC4/0-2 410-2 4/0-2 160 K LBS, 260 BTC250-6 250-4 4/0-6 160 K LBS. 260 BTC250-4 250-1 3/0-4 160 K LBS. 225 BTC250-2 250-1/0 4/0-2 160 IN. LBS. 260 BTC350-1/0 350-1/0 350-1/0 330 IN. LBS. 350 BTC500-4 500-2/0 4/0-4 330 K LBS. 260 BTC500-1/0 500-4/0 350-1/0 330 IN. LBS. 350 BTC500-14 750-3/0 10-14— 80 IN. LBS. 40 BTC750-250 750-250 500-250 3301N. LB& 430 +10-14 Cu SOLID/STRANDED, 10-12 Al SOLID/STRANDED ++2-10 Cu SOLID/STRANDED; 2-10 At STRANDED ++-2-10 Cu SOLID/STRANDED; 2-8 Al STRANDED -+-,+10-14 Cu SOLID/STRANDED: 10-12 Al STRANDED Full line is 600V dual -rated, 194'F(90'0) * Based on NEC Table 310-16 1996 (Not more than 3 insulated conductors in a raceway at ambient temperature of 30' C) for the largest tap wire size. A ZhWARNING: Cancer and Reproductive Harm - www.P651fiJarninQs.ca.gov, AADVERTENCIA: Cancer y Done Reproductive - www.P65Wamings.ca.00v. One year limited warranty. See idealindcom for more information. Garantia limitada de up are. Visite www.idealind,com para obtaner detalles us la garanfia. C- A\ S T 0 11 T P q P UZ S 1800 S. Prairie Drive Sycamore, IL, U.&A 800-435-0705 - www.irlealind.covii im me 1375 Park Avenue -Sycamora, Illinois 60178 ® 815,895,5181 - www.idealind.com ALL IDEAL Customers 2/9/23 Subject: The Buchanan B-TAPO splice/tap connectors meet the 2020 NEC article 230.46 requirement for "line side applications" 'MF'81M- MW f—di 1 0- 1 ^F it ISUOUU11 numbers beginning with "BTU meet the requirements of article 230.46 of the 2020 NEC. These products have already been tested to the newer requirements. The installation instructions are in the process of being updated to show the required notation: "suitable for use on the line side of the service equipment". This change will take a few weeks to get into our production. In addition, the marking "SR" will be added to the product. That addition is in process and will take a few months to complete. This notice will provide confirmation to the inspectors that B-TAPO products meet the requirements of the 2020 and 2023 NEC article 230.46 "Spliced and Tapped Conductors". Sushil Keswani Director of Engineering IDEAL Industries, Inc., ZVVI5238 - Wire Connectors and Soldering Lugs Note: We are enhancing our systems and you may notice duplicate entrieslmissingloutdated data. During this interim period, please contact our Customer Service at ht s.-Ilwwwul.comlabout1locations it Connectors and Soldering Lugs IDEAL INDUSTRIES INC E5238 1375 Park Ave SYCAMORE, IL 60178 United States View model for additional information Insulated butt splice crimp type connectors, Model(s): BVSJ, EVLsz BVS5 Insulated flange spade type crimp cconnectors, Model(s): SV5-3.7 SVL5-4 SVL5-6 insulated flange spade type crimp connectors, Model(s): _FSNYDl -37 _FSNYD1 -4 FSNYQ1 -5 _FSNYD2-3.7 FSNYD2-4 FSNYD2-5 FSNYD5-3,7 FSNYD5-4 FSNYD5-5 Insulated hook type crimp connectors, Model(s): HNYQ1 -3,7 HNYD1 -4 HNYQ1 -5 HNYD2-3.7 HNYD2-4, _HNYD2-5 _HNYD5-37 ENYD5-4, _HNYD5-5 HVY1 -3.7 _HVY1 -4 _HVY1 -5 HVY2-4 HVY2-5 HVY5-3.7 HVY5-4 HVY5-5 Insulated locking spade crimp connectors, Model(s): LSNYD1 -3.7 LSNYD2-3.7 LSNYD5-3.7 LSNYD5-4 LSNYD5-5 LSNYDLI -4 LSNYDL1-5 LSNYDL2-4 LSNYDL2-5 Insulated multiple stud ring type crimp connectors, Model(s): _MSRNYDl -3753 _MSRNYD2-3753 MSRNYD5-3753 Insulated parallel connectors, Model(s): PVT1, _PVT14 Rya aVT22, Eya PVT8 Insulated pin type connectors, Model(s): PTNYD1 -12 PTNYD2-12, PTNYD5-13 Insulated ring type crimp connectors, Model(s): RNY814-11 RNYB22-11 _RNYD1-10 RNYD1-3.2 RNYD1-5 RNYD1-6 RNYD1-8 RNYD2-10 RNYD2-2 RNYD2-3,2 _RNYD2-6 _RNYD2-8 RNYD5-10 RNYD5-12 RNYD5-3.2 RNYD5-3,7 RNYD5-5 RNYD5-6 _RNYD5-8 RNYDL1-3,7 RNYDL1-4 RNYDL2-3.7 RNYDL2-41 RNYDL5-3,7 RNYDL5-4 RNYDM2-3.7 RNYDS1-3.7 RNYDS1-4 RNYDS2-4 RNYDS2- 5RNYDS5-4 RV1-3,2 RV1-5 RV1-6 _RV232 RV5-10 RV5-3.7 RV5-5 RV5-6 RV5-8 RVLI-4 RVL2-4 RVL5-4 RVM1-3.7 RVM2-3.7 RVY 1 - 3.2 Insulated spade type crimp connectors, Model(s): SNYD1 -3.2 SNYD5-3,7 SNYD5-5 SNYDL1 -3.71 SNYDL1 -4 SNYDL2-3.7 SNYDL2- 4 _SNYDL2-5 S_NYDL5-4 _SNYDLL1-3 7 SNYDLL2-3,7 SNYDM1-4 SNYDM2-4 SNYDS1-5 _SNYDS2-5 SVL1-3.7 SVL1-5 SVL2-3.7 SVL2 5 SVM1 -4 SVM2-4 SVY1-3,2 SVY2-3,2 SVYS-3.7 SVY5-5, SVYL1 -3.7 SVYL1 -4 SVYL2-3.7 —SVYL2-4 SVYL2-5 S_VYL5-4 —SVYLL1 -37 SVYLL2-3.7 —SVYM1-4 SVYM2-4 —SVYS1-5 —SVYS2-5 SVYS5-4 � Insulated splice connectors, Model(s): _PB1 - _PB2- PB5- (IJ III lip 11111-11 111111 ;1111 17; 1 � III Listed pressure cable connectors, Model(s): BHT1, BHT2, BHT5, BIN 1, BN2, BN5, _BNT1 - 16 _BNT1 4 BNT2-16 _BNT22 BNT5-20 aNm BNYQF1 BNYDF2 BNYDF5 BNYT1 BNYT2 _BNYT5 _BV1 BV3 _BV5 BVT14 BVT22 BVT8 Listed pressure ring terminal connectors, Model(s): _RNYB14-8 _RNYB8-11 RNYBL22-5 RNYBL22-6 Listed splicing wire connectors, Model(s): _L12 _L13 L1 5 Non -insulated f la nge spade crimp connectors, Model(s):_FSN1-37 _FSN1-4 FSN1-5 FSN2-3.7 _FSN2-4 _FSN2-5 _FSN5-37 _FSN5-4 FSN5-5 _FSNB1-37 _FSNB1-4 FSNBI-5, FSNB2-3.7 FSNB2-4 FSNB2-5 FSNB5-3.7 _FSNB5-4 FSNB5-5 FSNL1-3.71 FSNL2-5 Non -insulated hookcrimp connectors, Model(s): HN1-4 HN1-5, HN2-3.7 HN2-4 HN2-S HN5-3.7 HN5-4 HNS-S Non -insulated locking type crimp connectors, Model(s): LSN1-3.7 LSN2-3,7 _LSN5-37 _LSN5-4 _LSN5-5 LSN5-6 LSNL1-4 LSNL1-5 LSNL2-5 Non -insulated multiple stud ring type crimp connectors, Model(s): MSRNB1 -3753 Non -insulated parallel crimp connectors, Model(s): PNT 1 PNT 14 PNT 2 PNT 22 _PNT 5 PNT 8 _PNT1 _PNT2 PLATS Non -insulated pin type crimp connectors, Model(s): PTN1 -12 PTN2-12 PTN5-13 Non -insulated ring type crimp connector, Model(s): RNBl-10 RNB1-3.2 _RNB14-11 _RNB14-12 RNB14-16 _RNB1-6 RNB1-8 RNB2- 10 RNB2-2 RN82-6 RNB5-12 RNB8-12 RNBL1-4 RNBM2-3,7 RNBM2-3,7 RNBM8-5 _RNBS1-4 _RNBS14-5 RNBS2-4 RNBS2-5 RNBS5-4 RNBS8-6 Non -insulated spade type crimp connectors, Model(s): SN1-3.2 _SN2-32 SN5-3,7 SN5-5 SNB1-3.2 SNB5-3,7 SNB5-5 SNBL1-3.7 SNBL1-4 _SNBL2-4 _SNBL2-5 SNBL5-4 SNBL5-6 SNBLL1-3.7 SNBLL2-3.7 SNBM1-4 SNBS1-5 SNBS5-4 SNL1-3.7 SNL1-4 SNL2-3.7 SNL2-4 SNL2-5 SNLL1-3.7 SNLL2-3,7 SNM1-4 SNM2-4,SNS1-5 SNS2-5 SNS5-4 Pressure cable connectors, Model(s):KB- 1000 KB-2/0 _KB350 Kg_L4/0 KB-500 KB-800 _KS-1000 K�2 0 KS- 350 KS - KS - 500 KS - 800 Pressure terminal connectors, Model(s): FSVY1 -3.7 _FSVY1 -4 _FSVY1 -5 _FSVY2-37 FSVY2-4 FSVY2-5 FSVY5-3.7 FSVY5-4 FSVY5-5 _K-5655 K-5656 LSV1-3.7 LSV2-3.7 LSV5-4 LSV5-5 LSV5-6 LSVL2-4, LSVS1-4 LSVS1-5 LSVS2-5 LSVY1-3.7 LSVY2-3.7 LSVY5-3.7 LSVY5-4 LSVY5-5 LSVY5-6, LSVYL1 -4 LSVYL1 -5 LSVYL2-4 LSVYL2-5, MSRNB2-3753 _MSRVYl -3753 MSRVY2-3753 MSRVY5-3753 PTVYl-12 PTVY2-12 PTVY5-13 RVYl-10 RVY1-5 _RVY1-6 RVYI-8 RVY2-10 RVY2-2 RVY2-3.2 RVY2-6 _RVY2-8 RVY5-10 RVY5-12 RVY5-3.2 _RVY5-37 _RVY5-5 RVY5-6 _RVY5-8 RVYL1-3.7 _RVYL1-4 R L2-3.7 RVYL2-4 RVYL2-5 _RVYL5-3,7 RVYL5-4 _RVYM2-37 RVYS1-3,7 RVYS1-4 RVYS2-3,7 RVYS2-4 RVYS2-5 RVYS5-4 _SNBM2-4 SNYD2-3.2 TLK16-6 TLK25-10 _8 —RNYBM8-5 RNYBS14-6 Slicing wire connectors, Model(s): OK-2 (Pkg. cat No. 8 ) OK-3 (Pkg. cat No. 85), �21K-4 (Pkg. cat No. 86), 2K-5 (Pkg. cat No. 8 ) OK- 6W (Ekg__.cat No 88), OK-8 (Ekg_.cat No 90),2K 8W (NA) Splicing wire connectors, Model(s): 1_2 1_3 14 14-6, 13 199,199S, 20_0 20_02 2006-5_2008-5 2011 -S 22 10 22_12 23 29_9 222S 3_0 300, 32 33 3-4 34-0 36 37 38 39 M 40-0 400AL 43 5-0 615-069 66 70 80-0 Aa:lzO _AS-2 AS-2/0AS-350 AS-4 AS-4/0 AS-500 � AS-6,B1, _B2 _B4 BT-2, BTC 1/0-10 BTC _Y_Q14 BTC2/0-14 BTC250-4 BTC350-1/0 fij9AZ0_-10 BTC 4/0-2 B�0-6. BTC 500-110 nq 500-14 BTC 500-4 BTC1/0-10 EIC2&_-14 BTC250-4 BTC350-1/0, BTC4/0-10 BTC410-2 BTC4/0-6 BjQQQ:j&, BTC500-14 —BTC500-4 BV1, _BV1 _BV2 BV2 BV5, BV5, C-3 C-4, C5 KIZO— K1000 _K2 &ZZ-0 1K250 _K3 K3/0 _K350 _K4 K500, _K6 K750, _K8 KS10, _R1 LZg _S2 2LO— S250 _S3 S3/0 QM _S4 S500 S6 TRQ1 TRQ2 Al W2 W4 WT1 WT2 _WT3 WI4, WT6 WTW51 WTW52 WTW53 WTW54 Insulating caps or covers, for use on manufacturees splice caps, for 2011 -S connector, Model(s): 2014 Splicing Wire Connectors, Modef(s): BNT1, BNT2 Splicinig wire connectors, Model(s):H-1566 _H-1567 H-1570 H-1571 H-1572 H-1591 H-1592 H-1594 Terminal connectors, Model(s): 1_0 1_1 22 25_0 30_0 34_1 34_2 410 with insulating cap No. 411 with insulating cap _No417 412 with insulating cap _No417 451, 452, 45_4 4_8 49 49 Black 51::5 _59B 6M _71B# 7_2B# 73B#, _73B+ _74B _76B 76B+, 78B+, 82 K-5504 LSNL2-4 M-3, PV3-750 PV3-750 PV3-750 PV4-750, _PV4-750 _PV4-750 _RNBL2-4 _RNBS14-6 RNBS38-6 _RNBS38-8 _RNYB22-10 RNYBS8-6 RV2-6 RVL2-5 SV5-5 j8tTj _WT2 WT3, _WT4 WT41 WT51 WT52 WT53, WT54 WT6 Terminal Connectors, Model(s): RNB22-11 Wire Connectors, Model(s): 6_5 653 Wire Connectors and Soldering Lugs, Model(s): L22, L23, _L25 PS1 0, PS1 2, _PS2 _PS3 _PS4 _PS4S _PS5 PS6, PS8 # - The equipment (71 B, 72B and 73B) were also evaluated to the requirements of UL 2043 and are suitable for use in air handling spaces, * - May be followed by suffix B, J, T or X. NOTE - All models may be provided with or without prefix"V" or suffix "MP" or "V" and prefix `13P". All models may be followed by suffixes BT, UB or OF with or without a two or four digit number, with or without suffixes B, LP, NP, PF, PH, SP and/or T. Die Series terminals may be followed by Suffixes Ul, UT, UF, US, or UB, with or without a two to four digit number, with or without Suffix T or 13, followed by Suffixes SP, LP, NP, PF, or and/or NM, by PH or BE, with or without Suffixes NT, BS, and /or G. The appearance of a company's name or product in this database does not in itself assure that products so identified have been manufactured under UL Solutions' Follow - Up Service. Only those products bearing the UL Mark should be considered to be Certified and covered under UL Solutions' Follow - Up Service, Always look for the Mark on the product. UL Solutions permits the reproduction of the material contained in Product iQ subject to the following conditions: 1, The Guide Information, Assemblies, Constructions, Designs, Systems, and/or Certifications (files) must be presented in their entirety and in a non -misleading manner, without any manipulation of the data (or drawings). 2. The statement "Reprinted from Product iQ with permission from UL Solutions" must appear adjacent to the extracted material. In addition, the reprinted material must include a copyright notice in the following format: "(D2023 UL LLC." I ;�]1n�DU���N����1T�����T��U�rU ���L���Lj��|��LJ ����[/�\�> ����� ���_}| |�—| introducing Ecor'asten's patent pending Rockh. Srnart Slide, our sirnple solution for quickly installing the popular Rock|t rail -less racking system to composition shingle roofs, ` ~ Features & Benefits ° Eliminates the need to Pry up shingle courses and install a rneta|flashing ° Multiple opportunities tofind the rafter ° Noneed for additiuna!numteria\when architectural shingles are not level ~ Longer 6.75^slide avoids overlaps in sh|ng|ecouraes ~ Integrated flashing utilizes U|tnsGripTechno|og,v" to create O a watertight seal Pre -installed sealing pads are compatible with, all composition, shingle roofs, The compression achieved when Fastened Uothe roof creates e suparstrong watertight seal. In rnos1cases, the slide can bemounted tothe deck without the need for sealant, Alayer offlexible foam provides cushioning, which allows the waterproofing sealant toernbeddeep into the granules ofthe shingle as well astoOexib|y conform over the steps found on UDE ^ RION SLIDE BLK 6.75"' Rl SMART SCREW #12X3"" W/BW [fLR' NUMBER DESCRIPTION 5 20�1102 RI SMART SCREW # I 2X3'W/BW I ITEM NO. DESCRIPTION I I SELF TAPPING SCREW # 12 WITH SEALING WASHER ASSEMBLY Im 1 2,87 7- [72,8] - 31 [7.8] 1, J- 3.00 [7&2] MATERIAL STAINLESS STEEL, EPDM RUBBER FINISH MSU_, SLACK EcoFasten An ESDEC Company usxa,a�oaue, wvanou�n'oe�z|p�a�Aao�o EcoPasten 4141 West Van Buren St, Phoenix, AZ8S8O9 Attn.:EcoFastenSolar Engineering Department Re: EcoFasten Rocklt System, with Comp Slide orSmart Slide, Engineering Certification for Gable and Hip roofs. This letter addresses the structural performance and code compliance of EcoFasten's RocWtFlush Mount System. The contents of the letter shall be reviewed in its entirety before application to any projectdesign. The Rockit System is a proprietary rooftop mounting system used to support photovoltaic (PV) modules installed in portrait or landscape orientation and set parallel to the underlying roof surface. PV modules are supported by extruded aluminum RockIt Mount assemblies which are connected to a RockIt roof attachment, either the Rockit Comp Slide or Rockit Smart Slide, which is attached directly to the roof structure. Assembly details ofatypical Rock|tsystem and its core components are shown inExhibit EC[} 1.0� The Rockit Comp Slide assembly is shown in drawing EX-1 and the Rocklt Smart Slide assembly is shown in dram/ing85DO76. The EcoFasten Rockit System is designed and certified to the structural requirements of the reference standards listed below, for the load conditions and configurations tabulated in the attached span tables. a Minimum Design Loads for Buildings and Other Structures, ASCE/SE|7'16 ~ ZO18International Building Code, bythe International Code Council, Inc. « 2O2OFlorida Building Code ° SEAOC (Structural Engineer Association of California) report PV2-2017 Wind Design for Solar Arrays w Aluminum Design Manual ZD15,byThe Aluminum Association, Inc. a NDS-2018, National Design Specification for Wood Construction, by the American Wood Council The span tables provided inthis letter are certified based on the structural performance of EcoFastenRockit System inconjunction with Rock|tComp Slide orSmart Slide only, with nuconsideration ufthe structural adequacy of the PV modules, or the underlying roof supporting members. These tables are intended to be used under the responsible charge of a registered design professional where required by the authority having jurisdiction. It is the responsibility of the installer or system designer to verify the structural capacity and adequacy of the system components regarding the applied or resultant loads of any chosen array configuration. xx�o� Sincerely, No. 94247 P'. STATE OF Matthew Kuzi|a' PE NQ11 06/09/2023 [HIS I rEM HAS 'BEEN ELIECTROMCALLY SIGNED, AND SEALB]8Y�ATTHB06. NU�U\ PEOmO+E D�TE aeLOVVTHESEAL . [DN8DEREDS|GmB}AND SEABDAmDTHE S|GNATURE�,AUST"BE VERIFIED ONANY ELECT RDN|[ CO3P\El *EcoFosten An ESDEC Company us*eei_n-s|4mzW van�3 �i, e, i'Si ,s�z��,oe, �x, A/ 85009 usamnC �-,|e/aor auvwa,s-e IzooA � ama,cAoozm The tables included in this letter provide the maximum allowable spans of the Rockit System, when used in conjunction with one of the available roof mounts, as a Flush Mount System for the respective loads and configurations listed, covering wind exposure categories B, C.&D'roof zones provided inAS[E7-1Gfor enclosed and partially enclosed gable roofs with slopes less than or equal to 7' & enclosed and partially enclosed gable orhip roofs with slopes mf0°1o6Q° The tabulated spans are applicable when the following conditions are met: 1. Span isthe distance between two adjacent roof attachment points (measured atthe center ofthe attachment fasteners). 2. The underlying roof slope, measured between the roof surface and horizontal plane, is 01 to 601, 3. The mean roof height, defined as the average of the roof eave height and the roof ridge height measured from grade for roofs with pitches above 10 degrees and defined as the eave height for roofs with pitches less than or equal to 10 degrees, does not exceed 30 feet, 4, A clearance from the module top surface to the roof surface of 2" minimum shall be provided and the height of the array, the distance from the module top surface to the roof surface (defined as h2), shall not exceed 5", 5. Module length and area shall not exceed the maximum values listed on the respective span 6� All Flush Mount components shall be installed in a professional workmanlike manner per EcoFasten's Rockit Installation Manual and the requirements specified for the underlying roof supporting members in the certification letter of the selected roof attachment, Rockit Comp Slide or Rnck1tSmart Slide, are confirmed tobemet. 1. The Flush Mount System is designed as a Risk Category 11 structure as defined by ASCE 7-16 Table 2.Wind speed shall conform toA5[E7'16Fig, 26.5-1B (for Risk Category ||) and applicable state & local county/city amendmentstothe|B[0ospeda|vvindtopographicfeaturesaneindudedand both topographic coefficient (Kzt) and wind ground elevation factor (Ke) are taken as 1 O 3. Snow load used in the span tables is the ground snow and shall conform to ASCE 7-16 Fig. 72-1 and applicable state & local county/city amendments to the IBC. If the local jurisdiction specified snow load is in the format of a flat roof snow, it shall first be converted to a garound snow followin snow conditions are considered includin, unbalanced, driftin_y slid I ng-retentian,, oaltondn"mozL No rain -on -snow surcharge load is considered. The span tables do not apply to buildings which are intentionally kept below freezing, kept just above freezing, or unheated. ecofastenso�ar.cum| |un�s��wr p���e�m�:�m| |mn�o�s�r EcoFasten An ESDEC Company usxeamcuara-s wvan�,ms�-zmm�y us��|�a��Avc,Ste, ',00��em���za 4. The span tables reflect the ASCE 7 prescribed earthquake loads with the maximum magnitudes (a)For ground snow nugreater than 42pstSs!�2.Dgfor Site Class /\E\C, &D� (b) For ground snow greater than 65pstSs:51.Ogfor Site Class A,B'C, &D. (c) For ground snow between 42 and 6Spsf: Ss �5 1.5g for Site Class A, B, C, & D 5. Roof zones are defined by ASCE 7-16 Figure 30.3-2A to Figure 30.3-21 and are organized into three groups in which the zones share the same External Pressure Coefficients (GCp). Roof zones comprising each group along with each roof zone's size and location are depicted in Figures 1 and 2, 6.The maximum module cantilever length, measured from the module end tm1henea/es attachment point, shall be1/3rdofthe allowable span. For the Rockltmounting system, acantilever is defined as the distance from the end of a module free edge to a Rocklt Mount roof attachment. A module edge isnot free ifthere isaRucWtCoupling connection toanadjacent module onthat edge, 7. A 1.0" Tolerance for any specified dimension in this report is allowed for installation. Per ASCE7-1O: a=1O96ofleast horizontal dimension nfO,4h whichever issmaller, but not less than either 4%ofleast horizontal dimension or3ft0.9m0. Ifanoverhang exists, the edge distance shall bemeasured from the outside edge ofthe overhang. The horizontal dimensions used to compute the edge distance shall not include any overhang distances. B=Horizontal dimension of building measure normal to wind direction in ft (m) h=Mean roof height, in ft (m), except that eave height shall be used for 0 � 10 8=Angle ufplane ofroof from horizontal, |ndegrees. -9= ELIEVATTON PLAN Figure 1: ASCE 7 Roof Zones for Gable Roofs e !� 7' us���r f c,, W V an3urc- 5:2 m8-�)C)09 Figure 2: ASCE 7 Roof Zones for Gable Roofs 8'!�- 0!� 60 ' Grouping of ASCE 7-16 Roof Zones (Gable) Slope Group Group 1 Group 2 Group 3 Group 1 Group 2 Group 3 Group 1 Group 2 Group 3 Grouping of ASCE 7-16 Roof Zones (Hip) Slope Group Group 1 Group 2 Group 3 Group 1 Group 2 Group 3 Group I Group 2 Group 3 ecofautensolaoom| }on�a�a�r am��e�o�,�om| |8�8suy�r d Al EcoFasten An ESDEC Company �s rs-;ra.,., f,.� �� u . d Spans for Array Edge A module is defined as Exposed (per Section 29.4.4 of ASCE 7-16) if the distance from any of its free edges (an edge with no connectivity to other modules) to its facing roof edge (such as eave, ridge, rake, or hip) is greater than 0.5h (h is ASCE defined building height) AND if the distance from the same free edge to any other adjacent array or panel is greater than 4 feet. The maximum allowable span for Exposed Modules shall be the lesser of the following two: (1) The span value for the exposed module condition. (2) The span value determined by the site wind and ground snow load. eco' stensolar,mm info aco �sr .:jia, c, ;r�, 1877,859,37 r �*EcoFasten d� An ESDEC Company # Slide Span Tables