Loading...
HomeMy WebLinkAbout24-7611Zephyrhills City of Zephyrhills 5335 Eighth Street Zephyrhills, FL 33542 BAR-007611-2024 Phone: (813) 780-0020 Fax: (813) 780-0021 Issue Date: 02/06/2024 REINSPECTION FEES: (c) With respect to Reinspection fees will comply with Florida Statute 553.80(2)(c) the local government shall impose a fee of four times the amount of the fee imposed for the initial inspection or first reinspection, whichever is greater, for each subsequent reinspection. Notice: In addition to the requirements of this permit, there may be additional restrictions applicable to this property that may be found in the public records of this county, and there may be additional permit required from other governmental entities such as water management, state agencies or federal agencies. "Warning to owner: Your failure to record a notice of commencement may result in your paying twice for improvements to your property. If you intend to obtain financing, consult with your lender or an attorney before recording your notice of commencement." accordance with City Codes and Ordinances. NO OCCUPANCY BEFORE C.O. NO OCCUPANCY BEFORE C.O. CONTF ORSIGNATURE PE IT OFFICE RMIT EXPIRES IN 6 MONTHS WITHOUT APPROVED INSPECTION iii II in, 813-780-0020 City of Zephyrhills Permit Application Fax-813-780-0021 Building Department Date Received 2/5/2024 610-874-5000 Phone Contact for Permitting - Owner's Name Carmichael, Philip and Alana Owner Phone Number ( (813) 610-3635 Owner's Address 5028 18th Street ZephyrhillS, FL 33542� Owner Phone Number -------------- Fee Simple Titleholder Name Owner Phone Number Fee Simple Titleholder Address JOB ADDRESS 5028 i8th Street Zephyrhills, FL33542 LOT# 24 CITY SUBDIVISION x�ZE.Y1HIL4P14omOT PARCED62(}�5(30 I-O'F 24 & THE SOUTH 11 FT OF LOT25 PIPTAINED FROM PROPERTY TAX NOTICE) - WORK PROPOSED BLOCK 2 NEW CONSTR F—] ADDlALT SIGN DEMOLISH INSTALL REPAIR PROPOSED USE] SFR COMM OTHER TYPE OF CONSTRUCTION BLOCK FRAME STEEL DESCRIPTION OF WORK Remove and replace 7 windows size for size BUILDING SIZE [ SO FOOTAGE 129$ HEIGHT BUILDING S 9572 VALUATION OF TOTAL CONSTRUCTION =ELECTRICAL AMP SERVICE PROGRESSENERGY W.R.E.C, f ®J =PLUMBING =MECHANICAL $ VALUATION OF MECHANICAL INSTALLATION /! =GAS ROOFING 0 SPECIALTY = OTHER (} FINISHED FLOOR ELEVATIONS FLOOD ZONE AREA DYES NO BUILDER � COMPANY SIGNATURE REGISTERED Y t N FEE cuRREN Y l N Address License # ELECTRICIAN COMPANY _ SIGNATURE REGISTERED EEG RRCN Address License ft PLUMBER C—�yry" COMPANY SIGNATURE REGISTERED �1/=N Address ;;;�IIE7�111REII License # MECHANICAL COMPANY SIGNATURE l REGISTERED Y! N EE cuRREN Y l N Address _= License # OTHER il — ^{ COMPANY Power Home Remodeling SIGNATURE REGISTERED YIN EEE CURREN Address 4135 Crescent Park Dr, Riverview FL 33578 License # CRC1333662 RESIDENTIAL Attach (2) Plot Plans; (2) sets of Building Plans, (1) set of Energy Forms; R-O-W Permit for new construction, Minimum ten (10) working days after submittal date. Required onsite, Construction Plans, Stormwater Plans w( Silt Fence installed, Sanitary Facilities & 1 dumpster; Site Work Permit for subdivisionsllarge projects COMMERCIAL Attach (2) complete sets of Building Plans plus a Life Safety Page; (1) set of Energy Forms. R-O-W Permit for new construction. Minimum ten (10) working days after submittal date. Required onsite, Construction Plans, Stormwater Plans w/ Silt Fence installed, Sanitary Facilities & 1 dumpster. Site Work Permit for all new projects, All commercial requirements must meet compliance SIGN PERMIT Attach (2) sets of Engineered Plans. ""PROPERTY SURVEY required for all NEW construction_ Directions: Fill out application completely. Owner & Contractor sign back of application, notarized If over $2500, a Notice of Commencement is required (AlC upgrades over $7500) Agent (for the contractor) or Power of Attorney (for the owner) would be someone with notarized letter from owner authorizing same OVER THE COUNTER PERMITTING (copy of contract required) Reroofs if shingles Sewers Service Upgrades A/C Fences (PIOUSurveyiFootage) Driveways -Not over Counter if on public roadways -needs ROW 813-780-0020 City of Zephyrhills Permit Application Fax-813-780-0021 Building Department NOTICE OF DEED RESTRICTIONS: The undersigned understands that this permit may be subject to "deed" restrictions" which may be more restrictive than County regulations, The undersigned assumes responsibility for compliance with any applicable deed restrictions. UNLICENSED CONTRACTORS AND CONTRACTOR RESPONSIBILITIES: If the owner has hired a contractor or contractors to undertake work, they may be required to be licensed in accordance with state and local regulations. If the contractor is not licensed as required by law, both the owner and contractor may be cited for a misdemeanor violation under state law. If the owner or intended contractor are uncertain as to what licensing requirements may apply for the intended work, they are advised to contact the Pasco County Building Inspection Division —Licensing Section at 727-847- 8009. Furthermore, if the owner has hired a contractor or contractors, he is advised to have the contractors) sign portions of the "contractor Block" of this application for which they will be responsible. If you, as the owner sign as the contractor, that may be an indication that he is not properly licensed and is not entitled to permitting privileges in Pasco County. TRANSPORTATION IMPACT/UTILITIES IMPACT AND RESOURCE RECOVERY FEES: The Undersigned understands that Transportation Impact Fees and Recourse Recovery Fees may apply to the construction of new buildings, change of use in existing buildings, or expansion of existing buildings, as specified in Pasco County Ordinance number 89-07 and 90-07, as amended. The undersigned also understands, that such fees, as may be due, will be identified at the time of permitting. It is further understood that Transportation Impact Fees and Resource Recovery Fees must be paid prior to receiving a "certificate of occupancy" or final power release. If the project does not involve a certificate of occupancy or final power release, the fees must be paid prior to permit issuance. Furthermore, if Pasco County Water/Sewer Impact fees are due, they must be paid poor to permit issuance in accordance with applicable Pasco County ordinances. CONSTRUCTION LIEN LAW (Chapter 713, Florida Statutes, as amended): If valuation of work is $2,500.00 or more, I certify that 1, the applicant, have been provided with a copy of the "Florida Construction Lien Law —Homeowner's Protection Guide" prepared by the Florida Department of Agriculture and Consumer Affairs. If the applicant is someone other than the "owner", I certify that I have obtained a copy of the above described document and promise in good faith to deliver it to the "owner" prior to commencement, CONTRACTOR'S/OWNER'S AFFIDAVIT: I certify that all the information in this application is accurate and that all work will be done in compliance with all applicable laws regulating construction, zoning and land development. Application is hereby made to obtain a permit to do work and installation as indicated. I certify that no work or installation has commenced prior to issuance of a permit and that all work will be performed to meet standards of all laws regulating construction, County and City codes, zoning regulations, and land development regulations in the jurisdiction. I also certify that I understand that the regulations of other government agencies may apply to the intended work, and that it is my responsibility to identify what actions I must take to be in compliance. Such agencies include but are not limited to: - Department of Environmental Protection -Cypress Bayheads, Wetland Areas and Environmentally Sensitive Lands, Water/Wastewater Treatment, Southwest Florida Water Management District -Wells, Cypress Bayheads, Welland Areas, Altering Watercourses, Army Corps of Engineers -Seawalls, Docks, Navigable Waterways, Department of Health & Rehabilitative Services/Environmental Health Unit -Wells, Wastewater Treatment, Septic Tanks. US Environmental Protection Agency -Asbestos abatement. Federal Aviation Authority -Runways, I understand that the following restrictions apply to the use of fill: Use of fill is not allowed in Flood Zone W" unless expressly permitted. If the fill material is to be used in Flood Zone "A", it is understood that a drainage plan addressing a "compensating volume" will be submitted at time of permitting which is prepared by a professional engineer licensed by the State of Florida, If the fill material is to be used in Flood Zone "A" in connection with a permitted building using stem wall construction, I certify that fill will be used only to fill the area within the stem wall. If fill material is to be used in any area, I certify that use of such fill will not adversely affect adjacent properties. If use of fill is found to adversely affect adjacent properties, the owner may be cited for violating the conditions of the building permit issued under the attached permit application, for lots less than one (1) acre which are elevated by fill, an engineered drainage plan is required. If I am the AGENT FOR THE OWNER, I promise in good faith to inform the owner of the permitting conditions set forth in this affidavit prior to commencing construction. I understand that a separate permit may be required for electrical work, plumbing, signs, wells, pools, air conditioning, gas, or other installations not specifically included in the application. A permit issued shall be construed to be a license to proceed with the work and not as authority to violate, cancel, alter, or set aside any provisions of the technical codes, nor shall issuance of a permit prevent the Building Official from thereafter requiring a correction of errors in plans, construction or violations of any codes. Every permit issued shall become invalid unless the work authorized by such permit is commenced within six months of permit issuance, or if work authorized by the permit is suspended or abandoned for a period of six (6) months after the time the work is commenced, An extension may be requested, in writing, from the Building Official for a period not to exceed ninety (90) days and will demonstrate justifiable cause for the extension. If work ceases for ninety (90) consecutive days, the job is considered abandoned, FLORIDA JURAT (F,S. 117.03) " OWNER OR AGENT CONTRACTOR 'ONTRACTOR Subscribed and sworn to (or affirmed) before me this Sobs 'be sworn (or affi a )before me this, _Ia by 1 4, �­,,- t1 Who is/are personally known to me or has/have produced Who is/are per maty,l r wn to me or has/have prod ad as identification, as identification. Notary Public P 11Notary Public Commission No. Core yi sion JACQUELINE 80GES K—arde ­dfNotaryjtyped, prhn_ted_or —stamped— Name of No P -Z b`t&*M*n # HH 328672 EVkw Decenjiba 12, 2020 i NOTICE F COMMENCEMENT Permit Number Tax Folio Y Y1 The undersigned hereby gives notice that improvement will be made to certain Real Property... and in accordance with Chapter 713 Florida Statutes, the following information is provided in this Notice of Commencement 1. DESCRIPTION OF PROPERTY: t_eg l d sorrprran�Ot t�h properly end street address, if available) ft _ 2. GENERAL DESCRIPTION OF IMPROVEMENT: es CJ Y I D wit dowsfdo rs size this space reserved for recording INFORMATION3. OWNER O.LESSEE INFORMATIONCONTRACTED FOR THE IMPROVEMENT: r r= Interest in Property Remove and replace windows/doors Fee Simple Title Holder (if different from owner listed above) 4, CONTRACTOR: Name Edward Gilbert -Power Home Remod�g �n Phone Number 1 0 AddressContractors Name Address 6. LENDER'S NAME Lender's address Phone Number Phone Number 7. Person's within the State of Florida Designated by fawner upon whom notice or other documents may be served as provided by Section 713.13(1)(a)7., Florida Statutes. Name Phone Number Address 8. In addition, Owner designates of a copy of the Lienor's Notice as provided in Section 713 13(1)(b), Florida Statutes Phone number of person or entity designated by Owner to receive 9. Expiration of notice commencement (the expiration date will be 1 year from date of recording unless a different date is specified 20, WARNING OWNER ANY PAYMENTS MADE BY THE OWNER AFTER THE EXPIRATION OF THE NOTICE OF COMMENCEMENT ARE CONSIDERED IMPROPER PAYMENTS UNDER CHAPTER 713, PART 1, SECTION 713 13, FLORIDA STATUTES, AND CAN RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY A NOTICE OF COMMENCEME MUST BE RECORDED ANC? POSTED ON THE JOB SITE BEFORE THE FIRST INS CTION IF YOU INT TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BE COMMENCING W OR RECORDING YOUR NOTICE OF COMMENCNM T natur of C or Lessee or Owner s or Lessee`s tPn i Name end P+a tie Signatory's Title/Office) Authorized Officer/Director/Partner/Manager) State of Florida County of —hot Township h 5 _ The foregoing instrument was acknowledged before me this 2- day of r 20_2_t_ by Fill1I?' r 1 for I t (type of I i nority e g officer trustee, attorney in fact) (name of party on behalf of whom iristrument was executed) Personally Known or Produced Identification k. (Signature of Nota P lic—StateAfAa, CHRISTOPHE210. SLY MY COMMISsIOtf # HH 095877 ;_ _` EXPIRES. February 22, 2025 '� t`,°` untied Thru N Ary PuP11C UndewfW tWS Form IPS02 —Revised 01/13/15 Firefox about:blank 2 of 2 2/5/24, 10:5'1 Florida Building Code Online https://floridabLiilding.org/pr/pr_appjtl.aspx?param=wGEVXQwtD... V 1"A;M11-11 Mel BCIS Home Log Ini User Registration Hot Topics Submit Surcharge Stats & Facts Publications Contact Us a BCIS Site Map Links Search Product Approval USEW Public Use, > Arpflk'3tjcanlust > Application Detail a NINE' FL # FL33447-RI Application Type Revision Code Version 2023 Application Status Approved Comments Archived Product Manufacturer Address/Phone/Email Authorized Signature Technical Representative Address/Phone/Email Quality Assurance Representative Address/Phone/Email Category Subcategory Compliance Method Florida Engineer or Architect Name who developed the Evaluation Report Florida License Quality Assurance Entity Quality Assurance Contract Expiration Date Validated By Certificate of Independence Referenced Standard and Year (of Standard) Pella Corporation 102 Main St, Pella, IA 50219 (641) 621-6096 pellaproductapproval@pella,com Mary Rukashaza-Mukorne certifications@cws.cc Mary Rukashaza-Mukorne 102 Main Street Pella, IA 50219 (641) 621-3317 rukastiazamc@pella.com Dave Criscuolo 1900 SW 44th Avenue Ocala, FL 34474 (647) 651-0199 dcriscuolo@cws.cc Windows Single Hung Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer '—� Evaluation Report - Hardcopy Received Lucas A, Turner PE-58201 Keystone Certifications, Inc. 07/15/2030 Steven M. Urich, PE Validation Checklist - Hardcopy Received &33AA2 -R.I-C-01 - Eyalgep-Qrtl? EL15AB, Rdf. slandaiLd AAMA/WDMA/CSA 101/l.S.2/A440 PA TAS 202 y"I 2017 1994 1 of 3 1/11/24, 08:59 Florida Building Code Online Z: https://'floridabuiIding.org/pr/pr-app_dti.aspx?parai,n=-wGEVXQwtD... Equivalence of Product Standards Certified By Sections from the Code Product Approval Method Method I Option D Date Submitted 10/05/2023 Date Validated 10/05/2023 Date Pending FBC Approval 10/08/2023 Date Approved 12/13/2023 Summary of Products FL # Model, Number or Name Description 33447.1 SH-510 SH-510 Vinyl Flange/Fin Single Hung, Non -Impact Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +50/-50 Other: SH-510, Max, size 53.125" x 76". Glass complies with ASTM E1300. 33447.2 SH-510 Limits of Use Approved for use in HVHZ.* Yes Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: N/A Other: SH-510 Vinyl Single Hung, O/X, Max, size 52" x 71", see installation dwgs, for DR Glass complies with ASTM E1300 33447,3 SH-510 Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +60/-60 Other: SH-510, Max, size 52" x 96", Oriel. Glass complies with ASTM E1300. 33447.4 SH-510 Continuous Head & Sill Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: N/A Other: SH-510 Cont, Hd. & Sill, Max. size 72 7/8" x 61 3/4", see Installation Dwgs. for DR Glass complies with ASTM E1300. 33447.5 SH-510 Continuous Head & Sill Limits of Use Approved for use in HVHZ* No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: N/A Installation Instructions Fl_3_3447__RT__LI__PEL: 4Bp _� A! Verified By: Lucas A, Turner 58201 Created by Independent Third Party: Yes Evaluation Reports Created by Independent Third Party: Yes SH-510 Vinyl Flange/Fin Single Hung, Non -Impact Installation Instructions E-L,33442-RI-11-..f!EL:48.5-8.Pd-f Verified By: Lucas A, Turner 58201 Created by Independent Third Party: Yes Evaluation Reports EL33-44-Z-B.-I--AE-.,EyalR—ep-.Q.tt.N.LA-858. pdf Created by Independent Third Party: Yes SH-510 Vinyl Single Hung Oriel w/ HD Meeting Rail Installation Instructions Rdf Verified By: Lucas A, Turner 58201 Created by Independent Third Party: Yes Evaluation Reports E-L3-aA47-R-1.-AL-Eya-LR-ePo-rtEEL-2-9aB.PAI Created by Independent Third Party: Yes SH-510 Vinyl Single Hung, Continuous Head & Sill, Non- ImpacL Installation Instructions E_L33_4_4Z_R1_U._PUL442_Bp_df Verified By: Lucas A. Turner 58201 Created by Independent Third Party: Yes Evaluation Reports E-U,3A42-.Rl--&E--,F-ya!-R-epD-c.tPEL442—E3.p.cLf Created by Independent Third Party: Yes SH-510 Vinyl Single Hung, Cont. Head & Sill, Non -Impact Installation Instructions Verified By: Lucas A. Turner 58201 Created by Independent Third Party: Yes Evaluation Reports Other; SH-510 Cont. Hd. & Sill, Max. size 74 1/8" x 72", see I E!314-47-.-Rl-AE---Lv-a[-R-QP-Qr-t-Pf�i..-492—BP-d-f chart on Installation Dwgs. for DR Glass complies with ASTM Created by Independent Third Party: Yes E1300. i ---------- 1 Backj Next, l.1-11-1-1 ........... ­11� 2 of 3 1/11/24, 08:59 SINGLE HUNG - NON -IMPACT (SHOWNi ,l __.. ?VAX CAMPA— WX ac m FF M ..._ E. M xf :. ... f k..A£''S, ii<�; EOUAL SPLIT WAX r "'£„ PA,�. g r €AM$ mo 13ter,. x t ` A-S T� Elf L CI %. TABLE CONTENTS SEC-, CNmr-ws- '— EX 0w , , O§ 3 SCW D E A, NOTE (EYSTALLATC- 3 DETA _,..,_..., ... 6 mm MAX 14-�Wt lu"GE VvA xE� %AAX 45WT MIDI" m 13 5 �-fi SASH OR EL TEE ,P; C7 $ N-M �,MfrNAS DES Eta xW JPAC-LSE TO c LY,,0TH THE FL -R A wtcmGcom (F c. C E ET. JES 4 PRESSuEE "iAwgCs` (ma SKE .2 ' -WzGATTVE DEMNLOADS BASES ON. -EST ED PRESSURE AND -POWWE k LOADS 5ASE0 ON, TEST ESSE.WATE C= DE M, `3LOAD LRA3K�N FACTOR 4,$ WAS USED r0-1 WOOD ANC- a M-CULAP04S E M APPROVED eOAW ACT RCS Ai E t A T PR TESTt d£^° &13�%QJPIEDNWMIJE 0-1Mi ROOT. �x N q ^t'y a 43-PAWS P-V°'Ni'SFMO"4" $DEz;,WA.f.:-..X^IIS-+ssVv'"w'.R>.XNT D,"FikAbL,_ SAS-...,r B1,EDSASH ",0, S'�FCI4c N €n''�,, i'OUTS a PP" ,Y' TO AAURE AT : S N s' q % 2R L.a,r��A.,;.0. EX`: EEP CL T w. V2 4 2, ' L,01:AEED 4' FF E� 50T-4 E 40S Lucas Turner r 202109.26 14-1856 -'a` pow caarw. 10a Nk n stmot 610 PVC SINGLE HUNG�^ N Z 4 'p V,r-20,j-s D - �" - 7 -00AS A, T SCR 0,Z� E _, ''E; 9 63201 T r Ea C °zris 'v 24M OW EE�ktor To Tr PH. 941-380-i,514 ab i GENERA€. NOTESVIID kW ss-mts'. 44., €"EL-' 54 : SHEE E_. . 1231 CF6 !_ s " P--ssare ( SF3 with G-ms hypes A, R r Unit Sa, Eh Unit IM dt hs tnj 35 I1 27 *SC'!- i wit - 8 - +501- s i} s .a + d,7 . -75 € +501 ^75 i +W -75 59 z #I's *50j-75 ?a - '; $meµ i, 43 50?- ?S -5Dig--73. :€ + I-'M J17 33 X 1 -75 -5 I - -50 - 5 � / -75 ! - + i - W11-75 a ^ 1-75 -�-75 -50/-58,9'I 3; < 51 2a r -75 �5 P-7 µ5 -75 -50lr S v%1 75 +501 +501,75 1-75 { 377 53 V7 26 +sc- -75 4 f =75 +50f „7 -50/ -75 -. i _75 .1'. i _? + f -P *W / -71 -501- 3 '': + 35 - 55 27 �; M` d• .7. _ wi -75 /-75 1 +So a�5 *5 1 4F�/- � E�^� .5 59 id3: d -3a +5 3 f- /-75 -,5 s' ,'- � f +' -� .5 7 -W MWEALUD tax a 01'1ACw A. g ClAASS PpFA PME1 WSIZE V4TENDED GNO w W—lea r '"V 0 of'i�L�, I A I'll SPACE 5 7 +50!rc5 -7 X'a .,E 433"Ps �.3 5< E x W R r GLASS INPE.0 BE �> i O , E ° tWA4c " ele Gt3S' KtF kYPii IQ manta straet Pega4:A M 610 PVC SINGLE HUNG NON -IMPACT < K 0wo0 utr01- w' to Pao �� L 1101 r Q, 3:s `7 24a Owl € "Oz T-(; TO COMPARATIVE ANALYSk AND GLAZING DETAILS :i2 CF6 tHl �^: t�,,�i.�tC �xa ,,;€IUN WgE FT r ail SME 'SWONS SASa- SE TC" VE ,+*, S i' 3d1 c SaCT CM 2%, 23, 232E. 31, 36. 37 44 .«5,21. SS- ,64,67-68 £. —Al :c":ON C Pam, A 50219 F PE 1 201 i «3 En6�Ef3wi r+ , a PH. 944-M-£ 574 SECT. VE%V S 4 i,2 ML-1 ': SHEET 6 3 x I x PVCTRXWE A�u x PVC SAW PULL FALAAW H42n23 T4 S-Qn2el ME uZUS NOW UsEa MOTE. ALL MU 8 ARE AUMMUM 612,4 1A ES1 OT"SPI l "z ED, No to TD.a 5 FVC PUG SAL CoVER pm cam&bo M2 A air Vlt Peb 50219 610 PVC S114GLE HUNG N . jig ig-� .a Row a 2-a Tower F t SS201 Twos NOMO Nn CW Naln "r w TO camon, r PH. 0-3 e0-i S74 SAKAWD FXTRXIMS a-_, s I 4CF6 a, VAX f11, ' NOTES, ? '@1Si`AL'x ONE' ANCKOP A- EACH : 'x'AUAT�ON L&-ATXY,� SLL A54AE), .`: SHW AS RECE '?' E a-E WSTAvAAT01AN040R:w : ? ,,,;3, D REARAGSRVA M.X. #L. OW RUE SHU SrACK -09F ?sue a. E— SWVM "n" W- F %iE SPACE GgEA ER CHAN 1h6l " z PREStN`s' LOAD RccrL^ iE j £ HMA ;>,Il -1, B KABiVATED054K"EMN`a'=,``Ya Mas OP BETE WOOD Ems'vvsA "icy ALLOWED ALL t%3�>sA�,.w.�'s " �d,*i��' �;5 ka�t�rz� �?a � = �f� = k. �13 `."�' "<i�" � E ?�'��" �f4 'aY �7 Add"`c74� a� s �k'.a. v B LAA VWTALS OF DPeNA MIN F5833£ E TRKAIED IKKO Mt# 7 9EPROTECT ED-0PREVENT PEA T . S'86E-. FOR ap6ml s' w1 E E-UT "S�*,a�L BEYONjk WOOD B-„ XSr r" USED, W— IX, B DES ARE ONE, T A WMWV CENTER-T"7-hTEPSPACKC T4ALLSE iJ4,At1fTMftS0 n VVEEE� ALL F% T DmRSw 1' Pr MAWD"+:RYT VFOF sMOODiI NO METAL, E 7��rL�E���4�2���3. x:�ir�,��`.BSKSP.*�:.��.�;��Esa��`�.4 £�:=���E"€➢�°a2�";'�3�"", �:*�:TE"��`���sr.;��E> i"?Er,3"��Ti"�d�T�'"�atz�c;5��i""3 "T-r�T�%rLStE IU? T# ATES $ u. V. , ." THE Mk$F1:3V STREfiOTK WE:;. X E°VENIS K TOWN ks; sm:y, OAEI E C*,"'=t.CRFI> A1Z h EON4� WSSTRAT•" S SAY NO- _E;'E SEA{..ti r-LASg046 SST90ES,"%�«ES POP 014E;,f u WATEq RETSTVVE Cf 3s�N&ST to .�.;,�S�EL DOME' Y aDi L OMMG TWE c,..'ARENT iEPSID OF 3`Ei1Y i" a ' A" 1N NN°@�� WQf�� , FWVM J .� AIN Si. ' ..66 N f w SS PiAA°ja.VxWDV »-0zfX'Ef*3'; Diu) ISE Mon Amel POOR AW terra ^s€U.Tr i Z 0 A OWEdos � a8 dos 8i;a w = < X W 9 iu y v £'s' p ire #„„- - lilt 'folptzu Csas?3 zyw 0 tx#� taxi, w P6 #Eda "Eur�se� �Y��giari�E"t P. 4l- 90.1674 ANCHORSCHEDULS NOTES PEE.-15 125 `a E 6 YPC HEAD AN M- MMAM Su va$PTMEM? KNOW t BY -?'eia'£ALLEA €'AM'E AND OUT SCk"AWf? ViBO to ARE s sue; C�;k „ w'efY ;SEE i��se' U, EkABEDV N3' ..._ ........ Ur0 ERS V — E� hoI UM WE0 "#.. ETAv'E*' VIN ,III,, Ll w'6VW'T SEE Oaf, M WIN EDGE Cs'sm ball SEE IA_&Z t &Y ;-Ems RE ",; are= x Esr«3�---�-'; ".- OFAW) OUT W tAR 9 - ALxmT "fc AM DUE ,yi% �3rro Ns It Patna car' 1C2Maio aYw Poo A 9M9 wmwMwfr- PVC SINGLE HUNG NOWNWACT 0 0 " owl TSB �av,' AP :�k• � � a'xb ^, ' �i�.,s"' %%dT � ,��,"� el B,*,���3iil�� M, EI Mir mmammi 'i'c' °Am €s 7;N•. 'x'NwSAU,'--'K>t " %*3 k s7 i✓€ems ' MAS A TURNER. RE. , ..,.:.. vjAD AND shi SN L54 %�:i N<Nl It*,ON e4mef t mot I g MET LPG CIF CONSTRLCTREWGRADE A S CALLK i5 APPLE,:' i u Mkt .A00XT ANCARKE 9 NA&AMW`WP RE(Nts`REME TS AS MOS 9,10WS23 FEW54 8 'i:; S C b National Headquarters 2501 seaport Drive, Chester, PA 19013 888.736.6335 toll -free WWW,POWIERHRG.COM PROJECT AMENDMENT Buyer(s)' Information and Description of the Property: Project Number: 37-17179 January 22, 2024 of Agreement Philip Carmichael (813) 610-3635 (Philip's Celt) JanuaDatery 26, 2024 A Jana Carmichael Date of Amendment 5028 18th Street philipcarmichael@me.com Zephyrhills, FL, 33542 E-Mail Address I County: Pasco Township: Zephyrhills This Amendment ("Amendment") is to the CUSTOM REMODELING AND IMPROVEMENT AGREEMENT ("Agreement") by and between mower Home Remodeling Croup, LLC ("Contractor'), and "Buyer(s)" listed above. Contractor and Buyer(s) hereby agree to amend and modify the Agreement as indicated below. Other than as specifically indicated below, all the terms and conditions of the Agreement will remain in full force and effect. This Amendment is subject to the terms and conditions of the Agreement. The following additions, alterations, or deletions to the products and services Buyer(s) ordered are being made: Previous Project Price: $9,575,44 1 New Project Price: Previous Down Payments Required: $0.00 1 Additional Down Payment Required: $0.00 Previous Down Payments Collected: Additional Down Payment Collected: Additional Down Payment Still Due: $0.00 signed, and dated copy of Amendment on the date written below. Additional Notes: Philip Carmichael an °I Buyer Prepared by Christopher Bly on 01/26/24 at 11:40:54 EST AMENDED - UPDATED Windows: Living room 1 34,0"x60,0" SUMMARY: Project Price changed, Measurement adjusted, Grids changed WINDOWS: Model Fortress Style Single Hung Type Single Config Auto -Locks OPTIONS: Color White / White Grid Pattern Both Sashes : Colonial : Standard I Removal Florida Flange I Glass Strength Non -Tempered I Glass Options Clear Low-E I Additional Details None AMENDED - UPDATED Windows: Living room 1 34.0"x60.0" SUMMARY: Project Price changed, Measurement adjusted, Grids changed WINDOWS: Model Fortress Style Single Hung Type Single Config Auto -Locks OPTIONS: Color White / White Grid Pattern Both Sashes : Colonial : Standard I Removal Florida Flange I Glass Strength Non -Tempered I Glass Options Clear Low-E I Additional Details None AMENDED -UNDATED Windows: Kitchen 1 34,0"x35,0" SUMMARY: Measurement adjusted WINDOWS: Model Fortress Style Single Hung Type Single Config Auto -Locks OPTIONS: Color White / White Grid Pattern None I Removal Florida Flange I Glass Strength Non - Tempered I Glass Options Clear Low-E I Additional Details None AMENDED - UPDATED Windows: Guest bedroom 1 34,0"x60.0" SUMMARY: Measurement adjusted WINDOWS: Model Fortress Style Single Hung Type Single Config Auto -Locks OPTIONS: Color White / White Grid Pattern None I Removal Florida Flange I Glass Strength Non - Tempered I Glass Options Clear Low-E I Additional Details None AMENDED -UPDATED Windows: Office 1 34,0"x60,0" SUMMARY: Measurement adjusted WINDOWS: Model Fortress Style Single Hung Type Single Config Auto -Locks OPTIONS: Color White / White Grid Pattern None I Removal Florida Flange I Glass Strength Non - Tempered I Glass Options Clear Low-E I Additional Details None AMENDED - UPDATED Windows: Master bed 1 34.0"x60,0" SUMMARY: Measurement adjusted WINDOWS: Model Fortress Style Single Hung Type Single Config Auto -Locks OPTIONS: Color White / White Grid Pattern None I Removal Florida Flange I Glass Strength Non - Tempered I Glass Options Clear Low-E I Additional Details None January 26, 2024 11:40 AMENDED - UPDATED Windows: Master bed SINE 1 34.4"x59,75" SUMMITRY: Location changed, Measurement adjusted WINDOWS: Model Fortress Style Single Hung Type Single Config Auto -Locks OPTIONS: Color White / White : Grid Pattern : None I Removal Florida Flange I Glass Strength Non - Tempered I Glass Options Clear Low-E I Additional Details None January 26, 2024 11:40