Loading...
HomeMy WebLinkAbout24-7621REINSPECTION FEES: (c) With respect to Remspection fees will comply with Florida Statute 553.80(2)(c) the local government shall impose a fee of four times the amount of the fee imposed for the initial inspection or first reinspection, whichever is greater, for each subsequent reinspection. Notice: In addition to the requirements of this permit, there may be additional restrictions applicable to this property that may be found in the public records of this county, and there may be additional permit required from other governmental entities such as water management, state agencies or federal agencies. "Warning to owner: Your failure to record a notice of commencement may result in your paying twice for improvements to your property. If you intend to obtain financing, consult with your lender or an attorney before recording your notice of commencement." MM V�ISM accordance with City Codes and Ordinances. NO OCCUPANCY BEFORE C.O. NO OCCUPANCY BEFORE C.O. CONTRACTOR SIGNATURE PE IT OFFICE THOUT APPROVED INSPECTION M 813-780-0020 City of Zephyrhifls Permit Application Fax-813-780-0021 Building Department Elate ReCeCVed Phonemittin v itIf a } 4l of Owner's Name G at t Owner Phone Number Owner's Address i r cd v k� 4 b owner Phone Number 9 Fee Simple Titleholder Name Owner Phone Number Fee Simple Titleholder Address Dr i B JOB4ODRE55 W LOT # SUBDIVISION, PARCEL lei# y i E .od — (OBTAINED FROM PROPERTY TAX NOTICE) WORK PROPOSED FIEW CONSTR ADDIALT SIGN DEMOLISH � INSTALL REPAIR ® PROPOSED USE. SFR ED COMM OTHER TYPE OF OO BLOCK E:D FRAME STEEL � DESCRIPTION OF WORK BUILDING SIZE _:== SQ FOOTAGE HEIGHT I-tkk­.x VxWe tx,C .' 8. :" '. ". .€It ILYA vx e, W, I F"tkL _., BUILDING $ VALUATION OF TOTAL CONSTRUCTION =ELECTRICAL N i -da tt AMP SERVICE PROGRESS ENERGY 0 W.R.E.C. N PLUMBING S MECHANICAL $ VALUATION OF MECHANICAL INSTALLATION GAS ROOFING = SPECIALTY = OTHER FINISHED FLOOR ELEVATIONS FLOOD ZONE AREA =YES NO BUILDER ,.� E:=::= COMPANY 4kP4&�� '.aIGNkT � REGISTERED ,,,A!dcftdAs1_b3 ei L Pi a_ License# r LEC Ii 1AN COMPANY SIONAT OE EREb Y 1 N cE cuRRCN Y t N y� ddress License # E_�....�» .. PLUMBER COMPANY � ®� SIGNATURE E:=:= REGISTEREDY i N FEE GURREN YIN �_ Address License # MECHANICAL COMPANY SIGNATURE REGISTERED Y N FEE GURREN / Address License OTHER .�...�. _._.�COMPANY SIGNATURE._._ � REGISTERED} Y (N FEE WIREN Y t N Address License # RESIDENTIAL Attach (2) Plot Plans; (2) sets of Building Plans; (1) set of Energy Foarrsi R-O-W Permit for new construction, Minimum ten (10) working days after submittal date. Required onsite, Construction Plans, Stormoater Plans wl Sill Fence installed, Sanitary Facilities & S dumpster, Site Work Permit for subdivisionstlarge projects COMMERCIAL Aileen (2) complete sets of Building Plans plus a Lice Safety Page, (1) set of Energy Forms. R-O-W Permit for new construction. Minimum ten (10) working days after submittal date. Required onsite, Construction Plans, Stormwater PlansAd Silt Fence installed, Sanitary Facilities & 1 dumpster. Site Work Permit for all new projects. All commercial requirements must meet compliance SIGN PERMIT Attach (2) sets of Engineered Plans. *PROPERTY SURVEY required for all NEW construction. Directions: Fill out application completely. Omer & Contractor sign back of application, notarized If over $2500, a Notice of Commencement is required. (AIC upgrades over $7500) Agent (for the contractor) or Power of Attorney (far the owner) would be someone eAth notarized letter from owner authorizing same OVER THE COUNTER PERMITTING (copy of contract required) Retools if shingles Sewers Service Upgrades A(C Fences (Plut(SurveyJFootage) Driveways -Not over Counter if on public roadways -needs ROW 813-780-0020 City of Zephyrhills Permit Application Fax-813-780-0021 Building Department NOTICE OF DEED RESTRICTIONS: The undersigned understands that this permit may be subject to 'deed' restrictions" which may be more restrictive than County regulations, The undersigned assumes responsibility for compliance Will any applicable deed restrictions, UNLICENSED CONTRACTORS AND CONTRACTOR RESPONSIBILITIES: if the owner has hired a contractor or contractors to undertake work, they may be required to be licensed in accordance with ;late and local regulations, if the contractor is not ficensed as required by law, both the owner and contractor atity, be cited for a misdemeanor violation under state law. if the owner or intended contractor are uncertain as to what licensing requirements may apply far the intended work, they are advised to contact the Pasco County Building Inspection Division --Licensing Section at 727-847- 80mL Furthermore, if the owner has hired a contractor or contractors, he is advised to have the contractor(s) sign portions of the "contractor Block" of this application for which they will be responsible. If you, as the owner sign as the contractor, that may be an indication that he is not property licensed and is not entitled to permitting privileges in Pasco County. TRANSPORTATION IMPACTILITILITIES IMPACT AND RESOURCE RECOVERY FEES: The undersigned understands that Transportation Impact Fees and Recourse Recovery Fees may apply to the construction of new buildings, change of use. in existing buildings, or expansion of existing buildings, as specified in Pasco County Ordinance number 89-07 and 90-07, as amended. The undersigned also understands, that such fees. as may be due, will be identified at the time of permitting. It is further understood that Transportation Impact Fees and Resource Recovery Fees must be paid prior to receiving a -certificate of occupancy" or final power release. It the project does not involve a certificate of occupancy or final power release, the fees must be paid prior to permit issuance. Furthermore, If Pasco County Water/Sewer Impact fees are due, they must be paid prior to permit issuance in accordance Win applicable Pasco County ordinances. CONSTRUCTION LIEN LAW (Chapter 713, Florida Statutes, as amended): If valuation of work is $2,500,00 or more, I certify that 1, the applicant, have been provided with a copy of the "Florida Construction Lien Law—Hreetrowner's Protection Guide" prepared by the Florida Department of Agriculture and Consumer Affairs. if the applicant is someone other than the -owner", I certify that I have obtained a copy of the above described document and promise in good forth to deliver it to the "owner" prior to commencement, CONTRACTORISIONNER'S AFFIDAVIT: I certify that aft the information in this application is accurate and that all workwifi be done in compliance with all applicable laws regulating construction, zoning and land development. Application is hereby made to obtain a permit to do work and installation as indicated. I certify that no work or installation has commenced prior to issuance of a permit and that all work will be performed to meet standards of all laws regulating construction, County and City codes, zoning regulations, and land development regulations in the jurisdiction. I also certify that I understand that the regulations of other government agencies may apply to the intended work, and that it is my responsibility to identify what actions I must take to be in compliance. Such agencies include but are not limited to: Department of Environmental Protection -Cypress Bayheads, Weiland Areas and Environmentally Sensitive Lands, Water/Wastewater Treatment, Southwest Florida Water Management District -Wells, Cypress Baybeads, Wetland Areas, Altering Watercourses. Army Corps of Engineers -Seawalls, Docks, Navigable Waterways. Department of Health & Rehabilitative Services/Environmental Health Unit -Wells, Wastewater Treatment, Septic Tanks. US Environmental Protection Agency -Asbestos abatement. Federal Aviation Authority -Runways. I understand that the following restrictions apply to the use of fill: Use of fill is not allowed in Flood Zone "V' unless expressly permitted, if the fill material is to be used in Flood Zone "N', it is understood that a drainage plan addressing a "compensating volume" will be submitted at time of permitting which is prepared by a professional engineer licensed by the State of Florida, If the fill Material is to be used in Flood Zone "A' in connection with a permitted building using stem wall construction, I certify that fill will be used only to fill the area within the stem wall, If fill material is to be used in any area, I certify that use of such fill will not adversely affect adjacent properties, if use of fill is found to adversely affect adjacent properties, the owner may be cited for Violating the conditions of the building permit issued under the attached permit application, for lots less than one (1) acre which are elevated by fill, an engineered drainage plan is required. If I am the AGENT FOR THE OWNIFER, I promise in good forth to inform the owner of the permitting conditions set forth in this affidavit prior to commencing construction. I understand that a separate permit may be required for electrical work, plumbing, signs, wells, pools, air conditioning, gas, or other installations not specific -ally included in the application, A permit issued shall be construed to be a license to proceed with the work and not as authority inviolate, cancel, after, or set aside any provisions of the technical codes, nor shall issuance of a permit prevent the Building Official from thereafter requiring a correction of errors in plans, construction or violations at any codes, Every permit issued shalt become invalid unless the work authorized by such permit is commenced within six months of permit issuance, or if work authorized by the permit is suspended or abandoned for a period of six (6) months after the time the work is commenced. An extension may be requested, in writing, from the Building Official for a period not to exceed ninety (90) days and will demonstrate justifiable cause for the extension. if work ceases for ninety (90) consecutive days, the job is considered abandoned, WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TOCE FOR IMPROVEMENTS TO YOUR PROPERTY, IF YOU INTEND TO OBTAIN FINANCING, CONSULT OWNER OR AGENT Subscribed and sworn to (or affirmed) before me this by Who istare personally khowri to me or has/have produced as identification. Notary Public Commission No CONTRAC subscribed and sworn to (or affirmed) before me this by itift Ware personalty known to me or hasthave produced as identification, Notary Public Commission No. Warne of —Notary typed, printVd or —stamped — __lame 07 Notary typed, panted or _stamped THIS SPACE FOR CLEWS RIECORDMIG: NOTICE OF COMMENCEMENT Tax Follo/Parcelill: ()Z-/—(O - z/ —Oixe) _C41110"'C', THE UNDERSIGNED hereby gives notice that improvement will be made to certain real property, and in accordance with Chapter 713, Florida Statutes, the following information is provided in this Notice of Commencement: I. Description of property: (legal description of property, and street address if available) W 2. General description of improvement. 5, �5k �57 44 lems 3, Owner information: Fil 4 a. Name and address,,( / a /)rvt -4 De Me 4--k, /t t—o4i I 1 b. Plione number: c. Name and address of fee simple titleholder (if other than owner): 4. Contractor: d Ad, —2, '3 a. Name and address: A s ��Fl or c. /v, c, D'I �e /,!v fL. b. Phone number: 5, Surety: a. Narne and address: b. Arnorint of bond S c. Phone number: 6. Leader: a. Name and address-. b. Phone number: 7. Persons with the State of Florida designated by Owner upon whore notices or other documents may be served as provided in Section 713.13(1)(a)7, Florida Statutes: a. Name and address: b. Phone number: 8. In addition to himself, Owner designates the following person(s) to receive a copy of the Lienor's Notice as provided in Section 713. 13(l)(b), Florida Statutes: a. Narne and address: b. Phone manber: 9. The expiration date of the notice of commencement is one (1) year from the date of recording unless a different date is specified: WARNING TO OWNER: ANY PAYMENTS MADE BY THE OWNER AFTER THE EXPIRA-11ON OFTHE NOTICE OF COMMENCEMENT ARE CONSIDERED IMPROPER PAYMENTS UNDER CHAPTER 713, PART 1, SECTION 713.13, FLORIDA STATUTES, AND CAN RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO VOIJR PROPERIT, A NOTICE OF COMMIENCEMENT MUST BE RECORDED AND POSTED ON THE JOB SITE BEFORE ITIE FIRST INSPECTION, IF VOU INTEND TO OBTAIN FINANCING, CONSULT Willi YOUR LENDER OR AN ATTORNEY BEFORE COMMENCING WORK OR REC ,.,ORDING VOUR NOTICE OF COMMENCEMENT. Signature of Owner or Owner's Authorized Officer/Director/Partner/Manager Printed Natme Title/Office STATE OF FLORIDA COUNTY OF The foregoing instrument was acknowledged before me this day of A —&-I �- ('-C 7 ?, by �,20L_!J_ —L_ - (name of person) as (type of authority: e.g., officer, trustee, attorney -in -fact) for (name of party on behalf of wborn instrument was executed), who is personally known to me or who, has produced as identification. [Notary Stamp] Signature of Notary Public Verification Pursuant to Section 92325, Florida Statutes Under penalties of Perjury, I declare that I have read the foregoing and that the facts stated in it are true to the best of any knowledge and belief. Signature of Natural Person Signing Above F:\Sharec1\DDS\8UILDlNG113uilding forms\N0C.docx e ANDREW WALTERS Notary Public - State of Florida 4 Commission # HH 403465 My Comm, Expires Jul 8, 2027 Bonded through National Notary Assn d C 19 9 1 8 1 7 1 6 1 5 4 3 1 2 1 1 PV SYSYE M Contractor is responsible to verify the Ft of this amay prior to installation. The solar module array shown is based on the field Engineer liability for error/omission/FBC 2023 (S" edition Florida Building Code) & NEC 2020 is limited by adequacy FBC 202 (8 TH EDITION FLORIDA BUILDING CODE ENGINEER data provided by the contractor. Contractor shall contact the engineer K the array may not fit as projected, Satellite imagery and accuracy of information provided to engineer by ownedcontractor and by responsibilities per ESCDCO C-700. ALDER ICED STRUCTti L PLAN,shown may not cDrrect indicate potential current shading of property, Contractor is responsible to verify sun exposure and Y Y po 9 P Pert1' Po i P Standard General Conditions of the Construction Contract, Copyright O 2013 National Society of Professional) PY .. Y FRAMING OF UPLIFT SHEATHINGDWITHSTAND I ING CERTIFY r MODULE RACKING. AND i�,40DtiLES ANC'NITHSTAND WEND UPLIFT. LATERAL. FARCES AND EQUIPMENT DEAD LORDS WITH THE CON�tTYJN LATERSTRUCTUREFWELL ANDSAFE ACCOMMODATE PV SYSTEM MOUNTING, CONDITION FL 96469 ROOF -MOUNT, Shading of installation prior to installation- Engineers, American Council of Engineering Companies, and American Society Of Civil Engineers. THAT CONTRACTOR'S INSTALLATION OF THE PV SYSTEM IS IN ACCORDANCE WITH THE INSTRUCTIONS ON THIS PLAN, 3753 LOCKRIDGE DR. RISK CATEGORY LI, THIS IS ATTESTED TO BY MY SIGNATURE AND SEAL ON THIS PLAN AT THE UPPER RIGHT. LAND O LAKES, FL 34638 INSTALLATION NOTES (813) 4015-7060 alper@iceli-pe.com -THIS PAPER PLAN IS INTENDED TO PROVIDE THE ESSENTIAL INFORMATION NEEDED BY AHJ (AUTHORITY HAVING JURISDICTION) AND INSTALLERS. ® THIS IS A COMBINED SET OF STRUCTURAL AND ELECTRICAL PLANS, ® SOLAR EQUIPMENT ADDS LESS THAN 4-PSF (UNFACTORED) GRAVITY LOAD TO STRUCTURE. • SEE DRAWINGS & PHOTOS FOR MEANS & METHODS INFORMATION IN ADDITION TO THESE NOTES. • THERE SHALL BE A PV MODULE TO RAIL MOUNTING CLAMP AT EVERY MODULE/RAIL CROSSING POINT WITH MINIMUM 4 CLAMPS PER MODULE. ® ADJOINING MODULES ON SAME RAIL SHALL SHARE CLAMPS. • MODULES SHALL BE LANDSCAPE OR PORTRAIT AS SHOWN IN FIGURE 08.. ® PV MOUNTING RAILS SHALL BE INSTALLED PERPENDICULAR TO ROOF FRAMING. • CONTRACTOR SHALL NOT INSTALL ROOF ATTACHMENTS ON ROOF AREAS ABOVE OVERHANGS. ® THERE SHALL BE A MINIMUM OF TWO RAILS UNDER EACH PV MODULE. ® ROOF ATTACHMENT SPACING SHALL BE AS SHOWN IN FIGURE 08. • RAILS SHALL NOT CANTILEVER BEYOND OUTSIDE END OF ROOF ATTACHMENT BY MORE THAN 1-FOOT. m RAILS SHALL ATTACH TO ROOF THRU EITHER OF THE FOLLOWING METHODS: A. (2) CBS 304 MS X 60MM , WOOD SCREWS INTO RAFTER, BLOCKING, TRUSS MEMBER S. (4) CPS 304 M5 X 60 MM, WOOD SCREWS INTO ROOF SHEATHING. • ROOF ATTACHMENTS SHALL BE FLASHED AS SHOWN HEREON. ® ALL FLASHINGS SHALL BE INSTALLED IN A BED OF PLENTIFUL FLORIDA PRODUCT CONTROL APPROVED (PCA) POLYURETHANE ROOF SEALANT. ® CONTRACTOR/INSTALLER SHALL COMPLY WITH OEM INSTALLATION INSTRUCTIONS. m CONTRACTOR SHALL PROVIDE AHJ WITH ADDITIONAL INFORMATION AS REQUIRED. ENGINEER OF RECORD (EOR) PREFERS EMAIL COMMUNICATION: alper@iceii-PE.com 01 NOTES Y. 7 NNA ASCE 7-22, 29.4-4 GABLE ROOF 7 10 < 20 E7 118 , Exposure Category:. C h2 0.3$ FT. �. Risk Category: 12 LP 16.33 FT Mean Roof Height: h 12 FT. 1.5LP 9.50 FT. Qgo Basic Wind Speed (mph): P ( p) V 138 MPH W p 3.42 FT. 1 a { I r r r t Ground elevation factor: Ke 1 W 0 Topographic Factor: Kzt 1 B 30 FT. I Q I 0 t- Gust Effect Factor: G 0.$5 L 70 i Directionality factor: IKd 0.85 A 2i-6 SF. t i i f Velocity Pressure I Exposure CoefficietKz 4.85 I "Ya 0.67 qh ! 35.2 PSF ''a, I3 F7 PLAN ZONE di (ft.) d2 (ft.) GCp 'YE p (PSF) ALL - - - 0 45 1 k0,5 1, 2e 20 0.25 d1>h/Z -2.00 1 5 2n, 2r, 3e 3 0.25 dl<h/2 -2.60 1 -61A 3r 3 0.25 d11h/2 -3.15 1 -743 - -4.29 kW DC SYSTEM. -11- 76" X 41." PV MODULES- - PV AREA : 241 SF. 'UNFACTORED AVERAGE ADDITIONAL GRAVITY LOAD: 3 PSF -K2 SPLICE X WITHDRAWAL CAPACITY (Two center screws into rafter): 1320 LBF. > MAX UPLIFT FORCE PER TRIBUTARY AREA: 892 LBF (12 SF' 74.3 PSF) TOTAL NUMBER OF ROOF ATTACHMENTS: 22 E I K2 48-: '1 02 WIND LOAD CALCULATIONS.®® SCA E: N/A 4811.41 iJ 48-XL, SX-Tl3P=0,201 IDS stn.LEMODULE, RAIL, ROOF ATTACHMENT CROSS SECTION : NTs 9 8 Addi*iIii;: ASCFJB£ 1-= LSIURW 28.2s8r13 81T4173het kk II L. W-1144V zm"Oft, Fkttm6 arautt E{®YYSIOn: 8`13=1=779=2 3ss42 Quw 88y pwwft r lmvphl o&I—Rm 821brph 3D�MRI 103V-Ph I00-y—M 113Vmph aw"WiIoIi TV.* M 1Wvopi, A#{t t48v.0 3=01—M twin t>m~ t1%k, R#1tl 171~ 1,Wp1MR1 184Vm h DESIGN WIND SPEED 04 S G N0 K; 3c FF EAL [16 3 NMI, 13MM SOCKET [14 NMI, 13MM SOCKET K2 CROSS RAIL SYSTEM COMPONENTS SCALE'. NTS 7 6 IN STREET SIDE BUILDING ------- -----------� — ROOF FIRE FOOTPRINT ACCESS POINT i 1 A µr e EXISTING ASPHALT t5 - SHINGLE ROOF ON 7/16" PLYWOOD AND 24-INCH C-C RAFTERS/TRUSSES. $. F FAC% 1 d 1._------�—_ ---GAL------------- -- K2 48-XL RAIL, TYP. i I I I ROOF FIRE I I ACCESS POINT I I I I 1 I I------------- *FAC : NFPA-1 FIRE: ROOF AREA: ACCESSCLEARANCE 1920 SF J COS (18-)= 2019 SF. LAW 2028 Florida Building Code, PV INSTALLATION AREA= 241 SF. Residential 8th Edition R324LIL2 241 SF / 2019 SF =12! < 33 T-BOLTS 19 ------------ I I I I SLOPE=18' 1 FAC'. I ( .--------- -- ----- ROOF ATTACHMENT ,TYP. SEE FIGURES 05,06 & 07. A: ELECT. SVC. ENTRANCE Et: MAIN SVC. PANEL C: AC DISCONNECT D: COMBINER PV MODULE-- PV h ---- K2 MID CLAMP ASSEMBLY K2 YETI HIDDEN END ') CLAMP ASSEMBLY '.- - -BONDING T-BOLT 1 MAX. 4-1N. SERRATED J FLANGE HEX NUT i', TYR i -1 a=3' F M a- 3' In < p 0 0 CD z Li_i L ! CD CS I--- {/) I-- 00 i! I LJ i� CD D Ct3 p t � z0 0 z §i`t O 'U Q � i- - iJW� o� 0 z0o <L Pu,N VIEW Aissten Ele Cric, L_; C 48 SsaLE: 3f16" = t'-0•• :37718 `n L:'idian Are, Dade City, FL 33525 i352t458-171G K2 END CLAMP ASSEMBLY Es'13009620 --BONDING T-BOLT AE._LLC- K2SPLICE FOOT X MCCELLAN K2 CROSSRAIL 3 (4&XL) °' - -- K2 EverSeai, BUTYL CRS (CORROSION RESISTANT STEEL) M5X60 SELF -DRILLING WOOD SCREWS SEALANT I'). (WITH SEALING WASHERS), PRODUCT _J (4) INTO EXISTING SHEATHING (MIN. 7/16-IN.), C NTROLFLORIDA CONTROL APPROVED fPCAj RAFTER SHEATHING OR (2) INTO EXISTING RAFTER t TRUSS POLYURETHANE ROOF ATTACHMENT ATTACHMENT UPPER CHORD (MIN. 2x4-IN.) SEALANT INTO DRILL HOLES. K2 SPLICE FOOT XL INSTALLATION DETAILS SCA!E: NTS 4 3 2 1 I1 f= PROPERTY NOD £ F >ooarnAnow, rmAwuw ac�ow 1 M M 14 PV SYSYEM THIS PLAN IS CERTIFIED BY ENGINEER OF RECORD AS CODE COMPLIANT & APPROVED SYSTEM: 11- CANADIAN SOLAR HIKUBLACK CS3N-390 PV MODULES ELECTRICAL PLAN FOR FLORIDA USE IN ACCORDANCE WITH HB 1021 ON ELECTRICAL PLANS. 11- ENPHASE IQ8PLUS-72-2-US MICRO INVERTERS CONTRACTOR SHALL COMPLY WITH SOLAR PROVISIONS 2021 NFPA 1. hop Y�wW� qL enat;e-gov/Ses�BiIVN17]01021 s,'L _ __ 1-ENPHASE IQ COMBINER (X-IQ-AM1-240-4) 1. DRAWINGS INDICATE THE GENERAL ARRANGEMENT OF SYSTEMS. CONTRACTOR RESPONSIBLE FOR COMPLYING WITH ALL LOCAL OR VO AGE DROP CALCULATIONS & CONDUCTOR AND CONDUIT SCHEDULE (11 PV MODULES) NATIONAL CODE REQUIREMENTS AND EQUIPMENT INSTALLATION VD=2-L-R-1 / 1000 INSTRUCTIONS, I 'CURRENT -CARRYING Imp 1.25 iCONDUCTORSIN I TabIe310-15 TERM. INVERTS 2. ALL COMPONENTS MUST BE GROUNDED PER ARTICLES NEC (2020) 250 BRANCH R WIRE RUN x CONDUCTORS FILL I Vmp Imp (AMPS) (AMPS) R(ohms) L(ft) VD %VD IN FACTOR I CONDUIT I CABLE EGC SBASE ;AMP. (B)(2)(b) Comection F. DERATED TEMP. AMP. OCPD(AMPS) RATING AND 690. #1 11 BRANCH TO JUNCTION BOX 240 13.31 16.64 1.26 40 1.34 0.56 - - ENPHASE Q CABLE 6 AWG THM-2, COPPER 27 0.77 N/A 20.79 901c 3. ALL EQUIPMENT SHALL BE LISTED PER NEC 690.4(B), #1 11 JUNCTION BOX TO SUB -PANEL 13,31 16.64 1.26 30 1.01 0,42 1 10 AWG THWN-2, COPPER 10 AWG THWN-2-, COPPER 36 0.95 34.20 1x20 90°C 4. PER NEC 690.17, PROVIDE A WARNING SIGN AT ALL LOCATIONS WHERE - __240_j _ _ -- TERMINALS OF THE DISCONNECTING MEANS MAY BE ENERGIZED IN THE 11 SUB -PANEL TO AC DISCONNECT 1 240 133R 1 16,64 1.26 10 0.34 0.14 3 1 10 AWG THWN-2, COPPER 10 AWG THWN-2, COPPER 36 0.95 34.20 N/A - 90°C OPEN POSITION SIGN SHALL READ "WARNING- ELECTRIC SHOCK HAZARD- 11_ AC DISCONNECT TO MAIN DISC, PANEL 1 240 1 13.31 16.64 1.26 5 0.17 0L07 3 10 AWG THWN-2, COPPER 10 AWG THWN-2, COPPER 3fi� 0.95 34,20 25 901C DO NOT TOUCH TERMINALS- OR EQUIVALENT, 5. PER NEC 690-56, PROVIDE A PERMANENT PLAQUE OR DIRECTORY SHOWING ALL ELECTRIC POWER SOURCES ON THE PREMISES AT SERVICE ENTRANCE. PV MODULE RATINGS INVERTER RATINGS . . ... ... ...... I 6, INTERCONNECTION METHOD SHALL COMPLY WITH NEC (2020) 705.12. SUB -PANEL PV BREAKER SIZE PHOTOVOLTAIC DC PER INVERTER MODULE MAKE CANADIAN SOLAR NVERTER MAKE ENPHASE ------ - - --------- . ..... INVERTER MODEL IQ8PLUS-72-2-US MODULE MODEL HIKUBLACK CS3N-390 7, PV PERFORMANCE METER MAY OR MAY NOT BE REQUIRED BY THE AHJ COMBINER BREAKER PER RATED MPR CURRENT 10.6 I A PHOTOVOLTAIC AC OUTPUT . .. ... AND/OR UTILITY FOR INTERCONNECTION, NUMBER OF MODULES BRANCH MAX POWER :290 VA POWER RATED MPP VOLTAGE 36.8 V NOMINAL AC VOLTAGE 240 :V 390 W MAX. OUTPUT & ALL CONDUCTORS MUST BE COPPER, RATED FOR 600 V, 90 C' WET 11 PER STRING 20 A OPEN CIRCUIT VOLTAGE 44.1 v MAX. DC VOLTAGE v MAX. DC VOLTAGE (INVERTER) 60 V 11 MOD, AC OUTPUT CURRENT 113 A ENVIRONMET, TERMINALS ARE RATED FOR 75 C-. VOLTAGE AT MISR • 36.8 V I NOMINAL AC VOLTAGE MAX INPUT SHORT CURCUIT CURRENT .11.4 'A 9. UTILITY CONNECTION SHALL BE MADE BY BACKFEED -- - - ­­­- - ---­---­-­--- CURRENT AT MEE 110.60 A MAX. AC CURRENT 1.21 A BREAKER/AC DISCONNECT PER ARTICLE 690,9(A), (B). BACK -FEED SHORT CURCUIT CURRENT 11.38 A MAX DO SHORT CIRCUIT !A BREAKER SHALL BE LOCATED AT OPPOSITE END OF BUS FROM CEC INVERTER EFFICIENCY :97.5 1% -4 UTILITY SUPPLY & LABELED " DO NOT RELOCATE.', LOCATED INSIDE PANEL BOARD ENCLOSURE USING UNUSED TERMINALS, TERMINALS THAT WARrG ARE SUITABLE FOR DOUBLE LUGGING, OR USING OTHER WARNING WARNING WARNING WARNING ALL PLAQUES AND SIGNAGE REQUIRED BY MEANS IF NOT IN THE SAME LOCATION IN ELECTRIC S. K HAZARD. I LOCALLY -APPROVED METHODS AND HARDWARE, IN COMPLIANCE WITH 2020 NEC AND 202118 NFRA 1 WILL BE ACCORDANCE WITH NEC 690.56(6) ELECTRICAL SHOCK -0 DO NOT To TERMINALS. DUAL POWER SOURCES. I Vm-: 264 V ELECTRICAL SHOCK HAZARD. 0 NO USER-SCRVICABLE PARTS INSIDE. IF AGROUND FAULT IS INDICATED. WRAIALLY S I V,: 240 V NEC 705.12(A), THE PANEL BOARD SHALL HAVE SUFFICIENT SPACE TO INSTALLED AS REQUIRED. LABEL(S) WITH MARKING, -TURN RAPID TERMINALS H LINE AND LOAD SECOND SOURCE IS PHOTOVOLTAIC CONTACT AUTHORIZED SERVICER FOR GROUNDED CONDUCTORS S I C IN SYSTEM, ASSISTANCE. LABELS, WARNING(S) AND MARKING SHALL SHUTDOWN SWITCH TO THE'OFF* POSITION TO MAYBE UNGROUNDED AND ENERGIZED. IDES MAY B NERGIZED IN THE OPEN IMP :13.3 A ALLOW FOR ANY TAP HARDWARE AS REQUIRED BY NEC 1103 AND NEC COMPLY WITH ANSI Z535-4, WHICH REQUIRES SHUT DOWN THE ENTIRE PV SYSTEM ,'SHALL POSITION, L 312.8(A), THAT DANGER, WARNING, AND CAUTION SIGNS BE LOCATED WITHIN 3 FT OF SERVICE LABEL PLACEMENT LABEL PLACEMENT LABEL PLACEMENT LABEL PLACEMENT. LABEL PLACEMENT 10. PV SYSTEM DISCONNECT SHALL BE A VISIBLE KNIFE -BLADE TYPE USED THE STANDARD HEADER COLORS, DISCONNECTING MEANS THE TITLE SHALL COMBINER & INVERTER AC DISCONNECT, NEAR BREAKER, MAIN PANEL NEAR fAETEP, COMBINER BOX AC DISCONNECT, POP HEADER TEXT, AND SAFETY ALERT SYMBOL ON UTILIZE CAPITALIZED LETTERS WITH A (FRONT OF PANEL I DEAD FRONT) DISCONNECT THAT IS ACCESSIBLE AND LOCKABLE BY THE UTILITY. THE EACH LABEL- THE ANSI STANDARD REQUIRES MINIMUM HEIGHT OF 318"IN BLACK ON A RED EMERGENCY RESPONDER IN CASE OF EMERGENCY PV AC PHOVOLTAIC POWER DISCONNECT SHALL BE LOCATED WITHIN 5 FT OF UTILITY METER. A HEADING THAT IS AT LEAST 50% TALLER BACKGROUND, AND REMAINING TEXT SHALL THIS SOLAR PV SYSTEM Is SOURCE DISCONNECT SHALL BE GROUPED IN ACCORDANCE WITH NEC 230.72 THAN THE BODY TEXT, IN ACCORDANCE WITH BE CAPITALIZED WITH A MINIMUM HEIGHT THIS WITH RAPID SHUTDOWN CALL DISCONNECT NEC 110.21(B). OF 3116"IN BLACK ON WHITE BACKGROUND. ALSTON ELECTRIC, LLC. LABEL PLACEMENT 11. ALL CONDUCTORS MUST BE COPPER. A PERMANENT PLAQUE OR DIRECTORY SHALL TURN RAPID SHUTDOWN RACEWAY & COMBINER BOX SWITCH TO THEOFF 240 V 12. ALL CONDUCTORS AND RACEWAYS SHALL BE SUPPORTED ON BE INSTALLED PROVIDING THE LOCATION OF POSITIONTO SHUT OCAMN (352) 458-1710 VOPT ' INTERVALS AND BY METHODS REQUIRED BY NEC (2020). THE SERVICE DISCONNECTING MEANS AND THE ENTIRE P`1 By' 3TEW I L I,-, : 13.3 A TI THE PHOTOVOLTAIC SYSTEM DISCONNECTING LABEL PI, AGFMENT: LABEL PLACEMENT. PHOTOVOLTAIC SYSTEM 13. CONTRACTOR SHALL PROVIDE ADDITIONAL INFORMATION IF NPPA 11IA2-21aIAA,11 1221A LABEL PLACEMENT BY AC DISCONNEOT,INTERCONNEC UOk PV AC DISCONNECT EQUIPPED WITH RAPID REQUIRED BY AHJ. SPECIFICATIONS, CALCULATIONS, & LABELS ANDNEC&90,WCX1) PV AC DISCONNECT,INTERCONNECTION. MAIN PANEL ;HUTDOWN 14� FOR PREFERS EMAIL COMMUNICATIONS alper@iceii-pe.com G KALE NT5 MAIN SERVICE PANEL 64%CTRICAL NOTES. ELE_�TRIOAL N * ALL SERVICES SUPPLYING DWELLING UNITS TO BE PROVIDED WITH A SURGE D PROTECTIVE DEVICE (SPD), AS AN INTEGRAL PART OF EQUIPMENT OR LOCATED IMMEDIATELY ADJACENT. THE SPD MUST BE A TYPE 1 OR TYPE 2 SPD AS PER NEC 230.67. * MICROINVERTER BRANCH CIRCUIT CONDUCTORS ARE MANUFACTURED ENPHASE Q CABLES LISTED FOR USE IN 20A OR LESS CIRCUITS OF ENPHASE IQ MICROINVERTERS. THEY ARE ROHS, OIL RESISTANT, AND UV RESISTANT. THEY CONTAIN TWO 12 AWG CONDUCTORS OF TYPE THHNITHWN-2 DRYIWET AND E CERTIFIED TO UL3003 AND UL 9703 * ENPHASE SYSTEM MEETS REQUIREMENTS FOR PHOTOVOLTAIC RAPID SHUTDOWN SYSTEM (PVRSS), AS PER NEC 690.12(B). MAX DC VOLTAGE OF PV MODULE IS 46.9 V AT VC (1 -C - 25-C) X -0. 1 147V/C + 44.1 V = 46.9 V) * AC AGGREGATION PANEL BUSBAR AND THE OVERCURRENT PROTECTION PROTECTING THE BUSBAR SHALL BE SIZED IN ACCORDANCE WITH NEC F 705.12(B)(2)(3)(C). 03 ELECTRICAL DIAGRAM 3CAL -E NT5 X11 TO GRID E BI-DIRECTIONAL, METER 1r,-7j1 Lf!=� EXISTING AC DISTRIBUTION PANEL 120/244V, 11$17 3W 200A PANEL 200A MAIN BREAKER mm JUNCTION BOX ENPHASE Q CABLE, �Q-12-RAW-240(TYP.), UL 1741, NEMA 3R, PV WIRE TO THWN-2 #6 THWN-2 EGC, IN FREE AIR TRANSITION, TYP. 3/4" LFNC CONDUIT' 11 (2) #10 THWN-2 CONDUCTORS (1) #10 THWN-2 GROUND, TYP. ------ (SEE NOTE #8) ­7= PV PERFORMANCE ENPHASE ENVOY METER. (OPTIONAL) (SEE NOTE #7) ow *CONTRACTOR SHALL INSTALL A SUPPLEMENTAL GROUNDING ELECTRODE IF EXISTING GEC CANNOT BE VERIFIED LABEL PLACEMENT'. DO DBCONNECTANVERTER BRANCH BRANCH CIRCUIT #1 11 MODULES < CANADIAN SOLAR HIK-UBLACK CS3N-390 AND ENPHASE IQ8PLUS-72-2-US E91 1 MICRO INVERTERS @ 240 VAC PV AC DISCONNECT, i NEMA 3R, UL LISTED 5A 60A, 240V, 2-POLE MODULES AND RACKING GROUNDED INDEPENDENTLY TO BARE COPPER IT 0 rp2A' j WIRE VIA LAY -IN LUGS, OR GROUNDED WITH WEEB WASHERS OR UL 2703 COMPLIANT RACKING PER NEC 250,4(6) AND PART Ill OF NEC ARTICLE 250 BRANCH TERMINATOR (ET -TERM), TYP. LOCATED WITHIN 5 FT OF UTILITY METER N Gf #10 THWN-2 CONDUCTORS & ------ 7J (1) #10 THWN-2 EGO IN ENPHASE 10 3/4- FMC OR EMT, OR 3/4" PVC OR LFNC COMBINER NEC 2020, TABLE C.3 MAXIMUM NUMBER NEC 2020, TABLE C.5 MAXIMUM NUMBER FOR OUTDOOR USE (X-IQ-AM1-240-4) OF CONDUCTORS OR FIXTURE WIRES IN OF CONDUCTORS OR FIXTURE WIRES IN FLEXIBLE METAL CONDUIT LIQUIDTIGHT FLEXIBLE (SEE NOTE #8) (FMC) NONMETALLIC CONDUIT (TYPE LFNC-B-) NEC 2020, TABLE C. I I MAXIMUM NUMBER OF CONDUCTORS OR FIXTURE WIRES IN RIGID PVC CONDUIT, SCHEDULE 40 AND HDPE CONDUIT (TYPE PVC SCH. 40) ENPHASE IQ8PLUS-72-2-US DC AND AC CONNECTORS CONFORM TO NEC 690.17(E) REQUIREMENT THAT INVERTERS INCLUDE DISCONNECTS FROM ALL SOURCES OF POWER. NATIONAL ELECTRICAL CODE, NEC (2020) ENGINEER ALPERICELI FL 90469 3753 LOCKRIDGE DR. A LAND 0 LAKES, FL 34638 (813)406-7060 aiper@iceli-pe.com \o%%till///, R1 No. "469 STATE OF I Ot < 0 ui z < C-D 0 :D,Lu Lij ry W CD c < 0 z Z 0 NT 0 - 1 VU LL 0 Ln Lu < Lu o CONTRACTOR: A E L F! 33�,2e, IM EC AE-LLC- 1 MCCELLAN PROPERTY NOTICE All I W-LALT-1- 111F Al .11 BA "AK-F1 4 I MW Enphase IQ Combiner 4/4C MOSEL NUMBER N R a 120 t' OAI �LAm 2- 25-W.g 215SRK15�4P,Zf �Ea8AK-2CAW l—A , BR215 Ci 0-gbrw.�-,Z�.2aF, a .0hYdd— A l.0.1W51,F—aR20 5R�29 14�O-29.F..MkSSN. =R i4c xAEztwrasAs RAP4 I ELECTRICAL SPECIFKAINONS 2Dl Za0 V 6 0 H 125A WA �A 90A MECHAWCAL DATA To leam more about Eroase offenngs, vmft AnrAftessIm ENPICAS E, 0 ZM Elot-- E-gy Agrl.a 1-1e6EV—'J. EIPhrne 'I C-- &,tc A ERS-C SHEET �—CoIME �11A M ENGINEERM DRAWM I..) 03N-aoms I I'll CUWVES R", View F,.— Croat sft-Oo. as A -A 3-8 2$ ---14 7 mo..dos Ho ElSallIC" DATA I STC* MECHANXAL DATA �119M-Pot-Tn-* 380W_3!5_W ......... V.kage(WYtp)36AV 36,6V 56,SV S70V 37.2V 9)1 Ana-W*M 132 [2 XTl I X 6) 1 lWXl049X35%mt (76AX413XI-38W) L 13@A, 11AA -A _ _ j11 �SNM9A!��) 3L ---- ---- ModuWE �CWW 18,7% 18.9% 192% 19A% 19.7% Front Cm,*r 32 MM TIAMP S! mcdul;e flre perfaxma_ TYPE I WL 61730 t TYPE 21UL61730 —Cabl 4 --,T(lECj IZAWG CUL) l0W,AwCLASSC0EC 17M Cable L-gth 9ndudingComtedon W00rttm(39,4frI)(lr App!Cld- Cla-Mcadl, Ct—A Pqw7olarapm 0-10W Re, pal we 30 pfecas Per C wda. Wm�me- ELfCMCAL DATA I NMCT- M 380W 38595 390Ms MIPS 40oms Nwt*Whtm?I,Pmwo MW 289W 293W 2%W 3EOW TEMPERATURE CRARACTER571C5 �3471Y S4,9V GurrerKa.7E.35A SA2A SASA 854A 8MA Shaft arCUlt Current (ISC) 9.08A 9A3A 9.18A 9.22A_9,27A___ TemperswreCoe cLe �(rsc) 0.05 % -C fk--m�w . — — —, d�- d p -- -------- ------- - CANA01AN SOLAR (USA), INC. JUIY2021 1 All rights reserved I PV Module Dacasheatvj7o_noj3_RA IMo 'ILE SPEC. SHEET NDIA IQ8 and 108+ Microinverters M. iW' DO vokage r 50 60 Do pwt it Rk 24S 300 2a0 290 240/2TI-264 t-0 lz NrnMrt%h to 64 50-68 T-1 #rarmoMc dj—wn C—ft."d..Acp- At 30 LA P..k.ft—y W.6 97 so =C—type MC4 212(.31 x1-- ("-, k 342 VX) WSkg(2Zaft) Cooling Natxa4ccrrvec:'ron-no Fans Y- daA aava' d.ty- PD1 G, ,lNVER"TEFl SPEC SHEET NATIONAL ELECTRICAL CODE, NEC (2020) ENGINEER ALPERICELI FL 90469 A 3753 LOCKRIDGE DR. LAND 0 LAKES, FL 34638 (813) 406-7060 alper@iceii-pe.com UN NO. 9046 ?t ST#,TE C ff Uj 4 N 0111111% A < 3:CG6 LLJ LU Z) z LLJ 0 < F— j U) U) Z> ry ce, < 0 z z nft 0 < t-0 LL _3 C) _3 r-A Uv] ,I oi� Ul COO < Alstor� Electric, LLC 3771P Werictiart Ave, Dacii, City, R- 33525 (352) 4 -58-17 10 EC1300982'0 AE LLC- MCCELLAN DATA JAN.29-24 PROPERTY NOTICE Im 19 0 I IP 9 8 7 6 S 4 3 ( 2 ) 3 PV SYSYEM Contractor is responsible to verify the fit of this array prior to installakion. The solar module array shown is based on the field Engineer IfaEltify for erradomissfonlFBC Z023 (8`h edition Florida Building Code} &NEC 2II241s limited by adequacy TH FBC 2023 {$ EDITION) FLORIDA BUILDING CODE ENGINEER F LAN, ROOF data provided by the contractor. Contractor shall contact the engineer if the array may not fit as projected, Satellite imagery and accuracy of information provided to engineer by owner/contractor and by responsibilities per EJCDC® C-700, I CERTIFY THAT THE SHEATHING 8 FRAMING OF THIS STRUCTURE SAFELY ACCOMMODATE PV SYSTEM AAPER iCEi! StiO`Mi may not correctly indicate potential current Shading of property. Contractor is reSpor4SIb18 t0 verify sun eXPOSiIre and Standard General Conditions of fit@ Construction GantfaCt, Copyright 17 2013 National Society of Professional WrCNG ON I RACKING, AND MODULES AND VIRHSTAhiD WIND UPLIFT f LATERAL FORCES AND EQUIPMENT DEAD LOADSWITH THE CONOkTION. CES THE CONDITION FL 90469 -MOUNT ©^�d1QLINT, Shading of installation prior t0 installation. Engineers, American Council of Engineering Companies, and American Society of Civil Engineers. THAT CONTRACTOR'S INSTALLATION OF THE PV SYSTEM IS IN ACCORDANCE WITH THE INSTRUCTIONS ON THIS PLAN . 3753 LOCKRIDGE DR. RISK CATEGORY 11" THIS IS ATTESTED TO BY MY SIGNATURE AND SEAL ON THIS PLAN AT THE UPPER RIGHT. LAND O LAKES, FL 34638 INSTALLATION NOTES (813)406-7060 aiper@iceli-pe.com -THIS PAPER PLAN IS INTENDED TO PROVIDE THE ESSENTIAL INFORMATION NEEDED BY AHJ (AUTHORITY HAVING JURISDICTION) AND INSTALLERS. ® THIS IS A COMBINED SET OF STRUCTURAL AND ELECTRICAL PLANS. ® SOLAR EQUIPMENT ADDS LESS THAN 4-PSF (UNFACTORED) GRAVITY LOAD TO STRUCTURE. • SEE DRAWINGS & PHOTOS FOR MEANS & METHODS INFORMATION IN ADDITION TO THESE NOTES. s THERE SHALL BE A PV MODULE TO RAIL MOUNTING CLAMP AT EVERY MODULE/RAIL CROSSING POINT WITH MINIMUM 4 CLAMPS PER MODULE, • ADJOINING MODULES ON SAME RAIL SHALL SHARE CLAMPS. ® MODULES SHALL BE LANDSCAPE OR PORTRAIT AS SHOWN IN FIGURE 08.. ® PV MOUNTING RAILS SHALL BE INSTALLED PERPENDICULAR TO ROOF FRAMING. ® CONTRACTOR SHALL NOT INSTALL ROOF ATTACHMENTS ON ROOF AREAS ABOVE OVERHANGS. • THERE SHALL BE A MINIMUM OF TWO RAILS UNDER EACH PV MODULE. • ROOF ATTACHMENT SPACING SHALL BE AS SHOWN IN FIGURE 08. • RAILS SHALL NOT CANTILEVER BEYOND OUTSIDE END OF ROOF ATTACHMENT BY MORE THAN 1-FOOT. • RAILS SHALL ATTACH TO ROOF THRU EITHER OF THE FOLLOWING METHODS: A. (2) CPS 304 MS X 60MM , WOOD SCREWS INTO RAFTER, BLOCKING, TRUSS MEMBER B. (4) CPS 304 M5 X 60 MM, WOOD SCREWS INTO ROOF SHEATHING, ® ROOF ATTACHMENTS SHALL BE FLASHED AS SHOWN HEREON. • ALL FLASHINGS SHALL BE INSTALLED IN A BED OF PLENTIFUL FLORIDA PRODUCT CONTROL APPROVED (PCA) POLYURETHANE ROOF SEALANT. ® CONTRACTOR/INSTALLER SHALL COMPLY WITH OEM INSTALLATION INSTRUCTIONS. • CONTRACTOR SHALL PROVIDE AHJ WITH ADDITIONAL INFORMATION AS REQUIRED. ENGINEER OF RECORD (EOR) PREFERS EMAIL COMMUNICATION: a€per@iceii-PE,com NorEs SG4kE: N(A ASCE 7-22, 29.4-4 GABLE ROOF 7 < Exposure Category: C B < 20 ------ FT. MPH PSF 16 18 h2 0.38 FT. LP 6.33 FT. 1 5 to 9.50 FT. WP 3.42 FT. w 0 B 30 FT. L 70 FT. A 21.6 SF. 7a 0.67 a 3 i FT. a a. a a �. T "-' n € I t # r + t r € € I I { (Ds.... I 0 t. € 1 1 t 1 5 € 1 s - } PLAN Risk Category: 12 Mean Roof Height: h 12 Basic Wind Speed (mph): V 138 Ground elevation factor: Ke 1 Topographic Factor: Kzt 1 Gust Effect Factor: G OS5 Directionality, Factor: 'Kd 0.85 Velocity Pressure Exposure Coefficient: oefficient Kz 10.85 qh 352 ZONE d1 (ft.) d2 (ft.) GCp "YE p (PSF) ALL - - - 0.45 1 10.6 1, 2e 20 0.25 dl>h(2 -2.00 1 5 2n, 2r, 3e 3 0.25 d1<h/2 -2,60 1 -61A 3r 3 0.25 dl<h12 -3.15 1 '4.29 ION DC SYSTEM. -11- 76.'X 41." PV MODULES. - PV AREA : 241 SF. "UNFACTORED AVERAGE ADDITIONAL GRAVITY LOAD: 3 PSF K2 SPLICE X WITHDRAWAL CAPACITY (Two center screws into rafter): 1320 LBf. > MAX UPLIFT FORCE PER TRIBUTARY AREA: 892 LBF (12 SF * 74.3 PSF) -TOTAL NUMBER OF ROOF ATTACHMENTS: 22 E I K2 48-, 11 9Z wiND LOAD CALCULATIONS SCAtE: N(A 48-XL, SX-Tg1,=0.201 in' MODULE, RAIL, ROOF ATTACHMENT CROSS SECTION STALE: MI5 9 8 P�vne: 434VMph > 23-y-U& 22 V,,Iph 90.y-MR1 IDS V-Ph lw-y_Wu Ils9 h Mat 1vv ph % 946Vtaph tacit IWVm01 IA Wvmr* ZWOW.MaI Ill Vargo. 1. r s%vo h DESIGN WIND SPEED 04 srAtE: Nrs K: 3C FF ML 116.3 NM), 13MM SOCKET [14 NMI, 13MM SOCKET _ K2 CROSS RAIL SYSTEM COMPONENTS SCAL: NTS 7 6 r 70' STREET SIDE -- - ROOF FIRE BUILDING F ACCESS POINT FOOTPRINT IF ROOFLINE —1 ---------- --------- k EI --------------- A O _ EXISTING, ASPHALT LS - SHINGLE ROOF ON 7/16" PLYWOOD AND 24-INCH C-C 1 SLOPE=18' RAFTERSfTRUSSES. V-8„ 1, 8' I I FAC'. FAG'. I TYP. }_—_------�—� 1---)--------------- —_ J I i l ROOF FIRE i ACCESS POINT I I L----- *FAC : NFPA-1 FIRE ACCESS CLEARANCE IAW 2023 Florida Elulld"ing Cflde, Residential 8th Edition R324.6.2 T-BOLTS W K2 48-XL RAIL, TYP. I I I i I 1 I ROOF AREA: 1920 SF t COS (18°p= 2019 SF. PV INSTALLATION AREA= 241 BE. 241SF12019SF=12! <33% F11, TYP, I I i I I l I 22' -14" 7 TYP. ...._._..._ _ I -- -] ROOF ATTACHMENT ,TYP. a=3' SEE FIGURES 05, 06 & 07. A: ELECT. SVC. ENTRANCE MAIN SVC, PANEL C; AC DISCONNECT D: COMBINER PV MODULE PV MODULE- �-. K2 MID CLAMP ASSEMBLY f —� - K2 YETI HIDDEN END € CLAMP ASSEMBLY I jMAX. 4-IN, J— '" -. - —--. -. BONDING T-BOLT _..._ SERRATED FLANGE HEX NUT ._„ K2 CROSSRAIL----- 333 (48-XL) a r - CPS (CORROSION RESISTANT STEEL) -- M5X60 SELF -DRILLING WOOD SCREWS ;i (WITH SEALING WASHERS), RAFTER ATTACHMENT SHEATHING ATTACHMENT (4) INTO EXISTING SHEATHING (MIN. 7l16-IN.), OR (2) INTO EXISTING RAFTER I TRUSS UPPER CHORD (MIN. 2X44N.) K2 SPLICE FOOT XL INSTALLATION DETAILS STALE: NTS 4 3 E 01 MW 12 I � � O Lt1 CD z w O _J C/iLU #CD UJ Lu ul p z z 0 Q f3 tUJ am 000-, 02<� Q. ff PLAN V€EW 48 SCALE" "= A Alston EleCtr=.c'., LLG E 37718 Meddier, Ave, Cabe City, FL 33525 ¢352; 458-1710 K2 END CLAMP EC13009620 ASSEMBLY -BONDING T-BOLT SPLICE FOOT X K2 EverSeai, BUTYL SEALANT I-). (') FLORIDA PRODUCT CONTROL APPROVED (PCA) POLYURETHANE ROOF SEALANT INTO DRILL HOLES. N STRUCTURAL JAN.29-24 COPYRIGHT & INTELLECTUAL PROPEK(Y NOTICE wNic„eeiaNvsmay.aceu, o,. F 1 9 8 7 6 5 4 0 11 III w PV SYSYEM THIS PLAN IS CERTIFIED BY ENGINEER OF RECORD AS CODE COMPLIANT & APPROVED SYSTEM: 11- CANADIAN SOLAR HIKUBLACK CS3N-390 PV MODULES ELECTRICAL PLAN FOR FLORIDA USE IN ACCORDANCE WITH HB 1021 ON ELECTRICAL PLANS. 11- ENPHASE IQ8PLUS-72-2-US MICRO INVERTERS CONTRACTOR SHALL COMPLY WITH SOLAR PROVISIONS 2021 NFPA 1" httpsa/www.fisenate. ov/Session JB7I112017 tJ( 1021r 1-ENPHASE IQ COMBINER (X-IQ-AMl-240-4) 1. DRAWINGS INDICATE THE GENERAL ARRANGEMENT OF SYSTEMS. CONTRACTOR RESPONSIBLE FOR COMPLYING WITH ALL LOCAL OR VOLTAGE DROP CALCULATIONS & CONDUCTOR AND CONDUIT SCHEDULE (11 Pv MODULES) - NATIONAL CODE REQUIREMENTS AND EQUIPMENT INSTALLATION VD=2*L*R*1 / 1°00 INSTRUCTIONS. LNG CONDUCTORS Ta(2)(b) .15 TERM. INVERTER 2. ALL COMPONENTS MUST BE GROUNDED PER ARTICLES NEC (2020) 250 BRANCH R WIRE RUN Im).12-1 . CONDUCTORS FILL CONDUCTORS IN IN Vmp Imp (AMPS}. {AMPS} R (ohms) L ('I VD %VD IN CONDUIT ] FACTOR CONDUIT ( CABLE EGO BASE AMP. (B){2}{b} Correction F. DERATED .TEMP. AMP, OCPD{AMPS} RATING AND 690. #1 11 BRANCH TO JUNCTION BOX 240 1 13.31 16,64 1.26 1 40 1.34 0.56 - - ENPHASE QCABLE 6 AWG THWN-2, COPPER 27 0,77 2039 N/A 901C 3. ALL EQUIPMENT SHALL BE LISTED PER NEC 690,4(B). #1 11 JUNCTION BOX TO SUB -PANEL 240 13.31 16.64 1.26 30 1.01 0.42 2 j 1 16 AWG THWN-2, COPPER 10 AWG THWN-2, COPPER 36 0.95 34.20 lx20 901C 4. PER NEC 690.17, PROVIDE A WARNING SIGN AT ALL LOCATIONS WHERE 11 TERMINALS OF THE DISCONNECTING MEANS MAY BE ENERGIZED IN THE SUB -PAN £LTD AC DISCONNECT 240 1331 6.64 26 10 0.34 0.14 3 1 10 AWG THWN-2, COPPER 10 AWG THWN-2, COPPER 36 0.95 34.20 N/A 901C OPEN POSITION. SIGN SHALL READ "WARNING- ELECTRIC SHOCK HAZARD- 11 AC DISCONNECT TO MAIN D35C. PANEL 240 13.31 1 16.64 1.26 5 0.17 4.07 3 1 10 AWG THWN-2, COPPER 10 AWG THWN-2, PER 36 _0.95 -- 3420 25 90°C DO NOT TOUCH TERMINALS- OR EQUIVALENT. 5. PER NEC 690.56, PROVIDE A PERMANENT PLAQUE OR DIRECTORY SHOWING ALL ELECTRIC POWER SOURCES ON THE PREMISES AT SERVICE ENTRANCE. 6. INTERCONNECTION METHOD SHALL COMPLY WITH NEC (2020) 705.12. sus -PANEL PV BREAKER sizE PHOTOVOLTAIC DC PER INVERTER _ .. _-. _-.R PER REQUIRED BY THE AHJ 7. PV PERFORMANCE METER MAY OR MAY NOT BE RE Q COMBINERBREAKER £ RATED MPP CURRENT :10.6 A PHOTOVOLTAIC AC OUTPUT AND/OR UTILITY FOR INTERCONNECTION. NUMBER of MODULES BRANCH _. RATED MPP VOLTAGE . _.__....._ _._...___ -� 36 8 . V NOMINAL AC VOLTAGE 240 V 8. ALL CONDUCTORS MUST BE COPPER, RATED FOR 600 V, 90 C° WET 11 PER STRING zo A - -- - - - --- - ----- -- __._.. MAX DC VOLTAGE (INVERTER) _._.-.-_.___ _._._ 6 V 11 MOD. AC OUTPUT CURRENT t3.3 A ENVIRQNMET, TERMINALS ARE RATED FOR 75 C°. y -- -- -- - ----- 9. UTILITY CONNECTION SHALL BE MADE BY BACKFEED MAX INPUT SHORT CURCUIT CURRENT' 11A ; a BR ER/AC DISCONNECT PER ARTICLE 690.9(A), (B). BACK -FEED BREAKER SHALL BE LOCATED AT OPPOSITE END OF BUS FROM PV MODULE RATINGS I MODULE MAKE CANADIAN SOLAR _ MODULE MODEL HIKUBLACK CS3N-390 i MAX. POWER _ 390 ,44.1 ........ W "V--..._. OPEN CIRCUIT VOLTAGE VOLTAGE AT MPP ' 36.8 V CURRENT AT MPP 10,60 A SHORT CURCUIT CURRENT 11.38 A INVERTER MAKE ENPHASE ! INVERTER MODEL 148PLUS-72 2 US i MAX. OUTPUT POWER 296 VA j MAX. DC VOLTAGE z6o < V NOMINAL AC VOLTAGE 240 , V !. MAX. AC CURRENT i 1.21 ;A { MAX DC SHORT CIRCUIT 15 A 1 CEC INVERTER EFFICIENCY i 975 i % UTILITY SUPPLY & LABELED DO NOT RELOCATE. , LOCATED INSIDE PANEL BOARD ENCLOSURE USING UNUSED TERMINALS, TERMINALS THAT WARNINGAR G WARNING - ARE SUITABLE FOR DOUBLE LUGGING, OR USING OTHER " ALL PLAQUES AND SIGNAGE REQUIRED B MEANS IF NOT IN THE SAME LOCATION IN x ° ° td '° ° G � � ELECTRI s t� t+AZAtTD. WARNING V : V [LECSF.IGAL SHACK HAZARD. MAX ELEGTf2fC4 SHOCK HAZARD. LOCALLY -APPROVED METHODS AND HARDWARE, IN COMPLIANCE WITH 2O20 NEC AND 202118 NFPA 1 WILL BE ACCORDANCE WITH NEC 690,56IG) DO NOT T TERMINALS. DUAL POWER SOURCES. NO USER SERVICABLE PARTS INSIDE. if A GRt3JND FAULT I$ iNf)iCATED, NORMALLY SECOND SOURCE IS PHOTOVOLI'AiC VMPP 24fl V CONTACT AUTHORIZED SERUCER FOR NEC 705.12(A). THE PANEL BOARD SHALL HAVE SUFFICIENT SPACE TO INSTALLED AS REQUIRED. 4 LABEL{S}WITH MARKING, TURN RAPED eRo NDeD OND CTORS ERMINALs H UNE AND LOAD ALLOW FOR ANY TAP HARDWARE AS REQUIRED BY NEC 110.3 AND NEC LABELS, WARNING(S) AND MARKING SHALL SHUTDOWN SWITCH TO THE"OFPPOSITION TO MAr sE UNGROUNDED LAND ERBRGOED. SIDES nsAYa NERGIZED IN THE OPEN. SYSTEM. 1�,p, :13.3A ASSISTANCE. COMPLY WITH ANSI Z535.4, WHICH REQUIRES SHUT DOWN THE ENTIRE PV SYSTEM.," SHALL POSITION. 1 312.8(A). THAT DANGER, WARNING, AND CAUTION SIGNS BE LOCATED WITHIN 3 FT OF SERVICE LABEL. PLACEMENT: LABEL PLACEMENT LABEL PLACEMENT: LABEL PLACEMENT: LABEL PLACEMENT: 10. PV SYSTEM DISCONNECT SHALL BE A VISIBLE KNIFE -BLADE TYPE USED THE STANDARD HEADER COLORS, DISCONNECTING MEANS THE TITLE SHALL COMBINER §INVERTER AC DISCONNECT, NEAR BREAKER, MAIN PANEL NEAR METER COMBINER BOX AC DISCONNECT, PCP HEADER TEXT, AND SAFETY ALERT SYMBOL ON UTILIZE CAPITALIZED LETTERS WITH A {FRONT 0, PANEL" DEAD FRONT) DISCONNECT THAT IS ACCESSIBLE AND LOCKABLE BY THE UTILITY, THE EACH LABEL. THE ANSI STANDARD REQUIRES MINIMUM HEIGHT OF 318" IN BLACK ON A RED �P $ [� (� PHOVOLTAIC POWER DISCONNECT SHALL BE LOCATED WITHIN 5 FT OF UTILITY METER. A HEADING THAT IS AT LEAST 50! TALLER BACKGROUND, AND REMAINING TEXT SHALL EMERGENCY RESPONDER IN CASE OF EMERGENCY 0 �+ r aT^-° THAN THE BODY TEXT, IN ACCORDANCE WITH BE CAPITALIZED WITH A MINIMUM HEIGHT THIS SOLAR PV SYSTEM IS I CALL A i"y. �y � � Si/URCE DISCONNECT SHALL BE GROUPED IN ACCORDANCE WITH NEC 230,72 THIS WITH RAPID SHUTDOWN DISCONNECT O NEC 110.21(B). OF 3(16" IN BLACK ON WHITE BACKGROUND. .` �° ALSTON ELECTRIC, LLC, LABEL PLACEMENT: 11. ALL CONDUCTORS MUST BE COPPER. A PERMANENT PLAQUE OR DIRECTORY SHALL TURN RAPID SHUTDOWN RACEWAY S COMBINER BOX 12. ALL CONDUCTORS AND RACEWAYS SHALL BE SUPPORTED ON BE INSTALLED PROVIDING THE LOCATION OF SAITCH TO THE OFF VA,: 240 V POSTION TO SHUT DOWN {352} 458-1710 1. 3.3 A INTERVALS AND BY METHODS REQUIRED BY NEC (2020). THE SERVICE DISCONNECTING MEANS AND THEENTJREPVSYSTEM. uPT THE PHOTOVOLTAIC SYSTEM DISCONNECTING LABEL PLACEMENT: LABEL PLACEMENT: PHOTOVOLTAIC SYSTEM 13. CONTRACTOR SHALL PROVIDE ADDITIONAL INFORMATION IF LABELPLPCEMENT: PVA-,DISCONNECTANTERCONNECTON, PVACDISCONNECT EQUIPPED WITH RAPID REQUIRED BY AHJ, AND NEC 699.56(cy.") PV AC DISCONNEC, IN ERCONNECTION, MAIN PANEL SPECIFICATIONS, CALCULATIONS, &LABELS MAIN BERNCEPANEL SHUTDOWN 14. FOR PREFERS EMAIL COMMUNICATIONS a)per@iceii-pe.com 02 sca T, ELECTRICAL NOTES. 01 scALE,uTs ALL SERVICES SUPPLYING DWELLING UNITS TO BE PROVIDED WITH A SURGE D PROTECTIVE DEVICE (SPD), AS AN INTEGRAL PART OF TO GRID EQUIPMENT OR LOCATED IMMEDIATELY ADJACENT. THE BI-DIRECTIONAL SIDE) MUST BE A TYPE 1 OR TYPE METER 2 SPD AS PER NEC 230.67. LABEL PLACEMENT: ENPHASE Q CABLE, UL 1741, NEMA 3R, DC DISCONNEC-UINVERTER JUNCTION BOX, Q-12-RAW-200 (TYP.), PV WIRE TO THWN-2 #6 THWN-2 EGG, IN FREE AIR TRANSITION, TYP. BRANCH 1 _ BRANCH CIRCUIT #1 3/4" LFNC CONDUIT: 11 MODULES CANADIAN SOLAR HIKUBLACK (2) #10 THWN-2 CONDUCTORS 11 1 CS3N-390 (1) #10 THWN-2 GROUND, TYP. AND (SEE NOTE #8) ENPHASE IQ8PLUS-72-2-US TEGRATED-I = _ = MICRO INVERTERS @ 240 VAC PV PERFORMANCE ENPHASE ENVOY METER. (OPTIONAL) (SEE NOTE #7) * MICROINVERTER BRANCH CIRCUIT _ CONDUCTORS ARE MANUFACTURED 200A PV AC DISCONNECT, _ ENPHASE Q CABLES LISTED FOR USE NEMA 3R, UL LISTED 15A IN 20A OR LESS CIRCUITS OF 60A, 240V, 2-POLE ENPHASE IQ MICROINVERTERS. 20A THEY ARE ROHS, OIL RESISTANT, 20A AND UV RESISTANT. THEY CONTAIN TWO 12 AWG CONDUCTORS OF TYPE THHN/THWN-2 DRY/WET AND CERTIFIED TO UL3003 AND UL 9703 LOCATED WITHIN raEUTRaL 5 FT OF UTILITY METER ENPHASE SYSTEM MEETS GROUND NJ REQUIREMENTS FOR PHOTOVOLTAIC RAPID EXISTING AC SHUTDOWN SYSTEM (PVRSS), AS DISTRIBUTION PANEL G - PER NEC 690.12(B). 120/24OV, 1�, 3W (3) #10 THWN-2 CONDUCTORS & 200A PANEL (1) #10 THWN-2 EGC IN ENPHASE IQ MAX DC VOLTAGE OF PV MODULE 200A MAIN BREAKER 3/4" FMC OR EMT, OR COMBINER IS 46.9 V AT 1 °C 1 °C - 25°C X ( ) 3/4" PVC OR LFNC (X-I0-AM1-240 4) -0.1147V/C * 44.1 V = 46.9 V) ' FOR OUTDOOR USE GEC I (SEE NOTE #8) AC AGGREGATION PANEL BUSBAR AND THE OVERCURRENT PROTECTION PROTECTING THE BUSBAR SHALL BE CONTRACTOR SHALL INSTALL IFj SIZED IN ACCORDANCE WITH NEC A SUPPLEMENTAL GROUNDING ENPHASE IQBPLUS-72-2-US DC AND 705.12(B)(2)(3)(C). ELECTRODE IF EXISTING GEC AC CONNECTORS CONFORM TO NEC CANNOT BE VERIFIED 690.17(E) REQUIREMENT THAT ELECTRICAL DIAGRAM INVERTERS INCLUDE DISCONNECTS FROM ALL SOURCES OF POWER. 9 8 7 - 6 :; 5 MODULES AND RACKING GROUNDED INDEPENDENTLY TO BARE COPPER WIRE VIA LAY -IN LUGS, OR GROUNDED WITH WEER WASHERS OR UL 2703 COMPLIANT RACKING PER NEC 250.4(B) AND PART III OF NEC ARTICLE 250 in BRANCH TERMINATOR (ET -TERM), TYP. NEC 2020, TABLE C.3 MAXIMUM NUMBER NEC 2020, TABLE C.5 MAXIMUM NUMBER OF CONDUCTORS OR FIXTURE WIRES IN OF CONDUCTORS OR FIXTURE WIRES IN FLEXIBLE METAL CONDUIT LIQUIDTIGHT FLEXIBLE (FMC) NONMETALLIC CONDUIT (TYPE LFNC-W) NEC 2020, TABLE C.11 MAXIMUM NUMBER OF CONDUCTORS OR FIXTURE WIRES IN RIGID PVC CONDUIT, SCHEDULE 40 AND HOPE CONDUIT (TYPE PVC SCH. 40) F NATIONAL ELECTRICAL CODE, NEC (2020) ENGINEER ALDER ICELI FL 90469 3753 LOCKRIDGE DR. LAND O LAKES, FL.638 (813)406-7060 alper@iceii-pe.com mm I cl c Lij LU C < F > 00 Li Lu 00 tr; N �I--r 0 .. O --- c LL UJ w w 0 Q 0 0 a ® � z o = Q LL s 19 CONTRACTOR: Ft P -1 G .;- L L: 377 f 3 Nlorkfi. ,€+.A, . D, a;1- G 'Y, r-L. 3 3 5 25 15, AE LLC- MCCELLAN �- ELECTRICAL ' .1W29-24 a m NATIONAL ELECTRICAL CODE, NEC (2020) ENGINEER ALDER tCELI FL 90469 3753 LOCKRIDGE DR. LAND O LAKES, FL 34638 (813) 406-7060 alper@iceli-pe.com I Atsaon Eiecti LLC .37718 ltendian Ave. �+ Dade :: cy, FL 33525 f ... l COMBINER SPEC. SHEET ��� PV MODULE SPEC SHEET G INVFERTER SPEC. SHEET s�21458-17 i 0 srn�: M/A a sc U n7A 0 scare c+lA EC"3Cv &23 �ggiyy'tEL+ —LL—��,,, gg lYios CEL 6N DATA JA .29-24 COPYRIGW & WELLECTUAL Pft4PERTY PkOME F F 1