HomeMy WebLinkAbout24-7689Issue Date:
"Warning to owner: Your failure to record a notice of commencement may result in your paying twice for
Will iiiiii III lill'! 111 1 111111 111 !ill I
accordance with City Codes and Ordinances, NO OCCUPANCY BEFORE C.O.
NO OCCUPANCY BEFORE C.O.
CONTRACTOR SIGNATURE PE T OFFICE
PERMIT EXPIRES IN 6 MONTHS WITHOUT APPROVED INSPECTION
813-780-0020 City of Zephyrhills Permit Application Fax-813-780-0021
Building Department
Date Received
Phone Contact for Permitting )
A RCn nn oRrnnrN
Owner's Name r
@ One Number
(873) 546 9011
N
Owner's Address 39038 9th Ave Zephyrhills, FL 33542
Owner Phone Number
m��
(813) 546-9011
Fee Simple Titleholder Name
Owner Phone Number
.n�
(£b13) 546-91111
Fee Simple Titleholder Address
JOB ADDRESS 39038 9th Ave Zephyrhills, FL 33542
LOT #
SUBDIVISION �T ^� PARCEL to#
12-26-21-002A-02300-0010
(OBTAINED FROM PROPERTY TAX NOTICE)
PROPOSED USE
TYPE OF CONSTRUCTION
NEW CONSTR ADD/ALT SIGN DEMOLISH
/ INSTALL REPAIR
SFR COMM OTHER
BLOCK E::] FRAME STEEL
BUILDING SIZE I SO FOOTAGE 812.61 HEIGHT
-.CtCECC-ttCt E-Ct ECE-$,ttCt-CE£C. "CE XX EC tt. E.0 E"V t�t k I-tt C; Ct"tCEt-C-t CtEt"I x:x x"E-tC CCt'E It
=BUILDING � I VALUATION OF TOTAL CONSTRUCTION
ELECTRICAL $ 42,357.85 AMP SERVICE PROGRESS ENERGY W.R.E.0
=PLUMBING S •_.._..e..._. __.._ ..
=MECHANICAL Is VALUATION OF MECHANICAL INSTALLATION
=GAS ROOFING SPECIALTY = OTHER
FINISHED FLOOR ELEVATIONS � FLOOD ZONE AREA =YES NO
BUILDER COMPANY
SIGNATURE REGISTERED Y / N FEE CURREN _ y / N
Address License #
,.... NIVO SOLAR L L C
ELECTRICIAN COMPANY
SIGNATURE (( t, REGISTERED Y / N FEE CURREN Y_! N�
Address 1600E AVE SUITE A200 TAMPA FL 33606 License # I EC13013357
PLUMBER COMPANY
SIGNATURE REGISTERED Y / N FEE CURREN Y / N
Address License #���
MECHANICAL COMPANY
SIGNATURE REGISTERED Y/N FEE CURREN Y/N
Address I License #
OTHER COMPANY
SIGNATURE REGISTERED Y 1 N FEE CURREN Y I N
Address E=— License #
RESIDENTIAL Attach (2) Plot Plans; (2) sets of Building Plans; (1) set of Energy Forms; R-O-W Permit for new construction,
Minimum ten (10) working days after submittal date. Required onsite, Construction Plans, Stormwater Plans wl Silt Fence installed,
Sanitary Facilities & 1 dumpster; Site Work Permit for subdivisionsilarge projects
COMMERCIAL Attach (2) complete sets of Building Plans plus a Life Safety Page; (1) set of Energy Forms. R-O-W Permit for new construction.
Minimum ten (10) working days after submittal date. Required onsite, Construction Plans, Stormwater Plans w/ Silt Fence installed,
Sanitary Facilities & 1 dumpster. Site Work Permit for all new projects. All commercial requirements must meet compliance
SIGN PERMIT Attach (2) sets of Engineered Plans.
""PROPERTY SURVEY required for all NEW construction.
Directions:
Fill out application completely.
Owner & Contractor sign back of application, notarized
If over $2500, a Notice of Commencement is required. (A(C upgrades over $7500)
— Agent (for the contractor) or Power of Attorney (for the owner) would be someone with notarized letter from owner authorizing same
OVER THE COUNTER PERMITTING (copy of contract required)
Reroofs if shingles Sewers Service Upgrades A/C Fences (Plot/Survey/Footage)
Driveways -Not over Counter if on public roadways..needs ROW
813-780-0020 City of Zephyrhills Permit Application Fax-813-780-0021
Building Department
NOTICE OF DEED RESTRICTIONS: The undersigned understands that this permit may be subject to "deed" restrictions" which may be more restrictive
than County regulations. The undersigned assumes responsibility for compliance with any applicable deed restrictions,
UNLICENSED CONTRACTORS AND CONTRACTOR RESPONSIBILITIES: If the owner has hired a contractor or contractors to undertake work, they
may be required to be licensed in accordance with state and local regulations. If the contractor is not licensed as required by law, both the owner and
contractor may be cited for a misdemeanor violation under state law. If the owner or intended contractor are uncertain as to what licensing requirements
may apply for the intended work, they are advised to contact the Pasco County Building Inspection Division —Licensing Section at 727-847- 8009,
Furthermore, if the owner has hired a contractor or contractors, he is advised to have the contractor(s) sign portions of the "contractor Block" of this
application for which they will be responsible. If you, as the owner sign as the contractor, that may be an indication that he is not properly licensed and is
not entitled to permitting privileges in Pasco County.
TRANSPORTATION IMPACT/UTILITIES IMPACT AND RESOURCE RECOVERY FEES: The undersigned understands
that Transportation Impact Fees and Recourse Recovery Fees may apply to the construction of new buildings, change of use in existing buildings, or
expansion of existing buildings, as specified in Pasco County Ordinance number 89-07 and 90-07, as amended. The undersigned also understands, that
such fees, as may be due, will be identified at the time of permitting. It is further understood that Transportation Impact Fees and Resource Recovery
Fees must be paid prior to receiving a "certificate of occupancy" or final power release. If the project does not involve a certificate of occupancy or final
power release, the fees must be paid prior to permit issuance. Furthermore, if Pasco County Water/Sewer Impact fees are due, they must be paid prior
to permit issuance in accordance with applicable Pasco County ordinances.
CONSTRUCTION LIEN LAW (Chapter 713, Florida Statutes, as amended): If valuation of work is $2,500.00 or more, I certify that 1, the applicant,
have been provided with a copy of the "Florida Construction Lien Law —Homeowner's Protection Guide" prepared by the Florida Department of
Agriculture and Consumer Affairs, If the applicant is someone other than the "owner', I certify that I have obtained a copy of the above described
document and promise in good faith to deliver it to the "owner" prior to commencement,
CONTRACTOR'S/OWNER'S AFFIDAVIT: I certify that all the information in this application is accurate and that all work will be done in compliance with
all applicable laws regulating construction, zoning and land development. Application is hereby made to obtain a permit to do work and installation as
indicated. I certify that no work or installation has commenced prior to issuance of a permit and that all work will be performed to meet standards of all
laws regulating construction, County and City codes, zoning regulations, and land development regulations in the jurisdiction. I also certify that I
understand that the regulations of other government agencies may apply to the intended work, and that it is my responsibility to identify what actions I
must take to be in compliance. Such agencies include but are not limited to:
Department of Environmental Protection -Cypress Bayheads, Wetland Areas and Environmentally Sensitive
Lands, Water/Wastewater Treatment,
Southwest Florida Water Management District -Wells, Cypress Bayheads, Wetland Areas, Altering
Watercourses.
Army Corps of Engineers -Seawalls, Docks, Navigable Waterways.
Department of Health & Rehabilitative Services/Environmental Health Unit -Wells, Wastewater 'Treatment,
Septic Tanks.
US Environmental Protection Agency -Asbestos abatement,
Federal Aviation Authority -Runways.
I understand that the following restrictions apply to the use of fill:
Use of fill is not allowed in Flood Zone W" unless expressly permitted.
If the fill material is to be used in Flood Zone "A", it is understood that a drainage plan addressing a
"compensating volume" will be submitted at time of permitting which is prepared by a professional engineer
licensed by the State of Florida.
If the fill material is to be used in Flood Zone "A" in connection with a permitted building using stem wall
construction, I certify that fill will be used only to fill the area within the stem wall.
If fill material is to be used in any area, I certify that use of such fill will not adversely affect adjacent
properties. If use of fill is found to adversely affect adjacent properties, the owner may be cited for violating
the conditions of the building permit issued under the attached permit application, for lots less than one (1
acre which are elevated by fill, an engineered drainage plan is required,
If I am the AGENT FOR THE OWNER, I promise in good faith to inform the owner of the permitting conditions set forth in this affidavit prior to
commencing construction. I understand that a separate permit may be required for electrical work, plumbing, signs, wells, pools, air conditioning, gas, or
other installations not specifically included in the application. A permit issued shall be construed to be a license to proceed with the work and not as
authority to violate, cancel, alter, or set aside any provisions of the technical codes, nor shall issuance of a permit prevent the Building Official from
thereafter requiring a correction of errors in plans, construction or violations of any codes. Every permit issued shall become invalid unless the work
authorized by such permit is commenced within six months of permit issuance, or if work authorized by the pen -nit is suspended or abandoned for a
period of six (6) months after the time the work is commenced. An extension may be requested, in writing, from the Building Official for a period not to
exceed ninety (90) days and will demonstrate justifiable cause for the extension. If work ceases for ninety (90) consecutive days, the job is considered
abandoned.
(F.S, 117
OWNER OR AGENT BRENDA BROWN
Subscribed and sworn to (or affirmed) before me this
Who is/are personally known to me or has/have produced
as identification.
Public
Commission
Name of Notary typed, printed or stamped
!L 11AIIIIIIIIAZIONLORMZIMI 2 i FM I
CONTRACTOR JEREMY SHANE TURNER
Subscribed and sworn to (or affirmed) -before me this
Who is/are personally known to mle or has/have produced
as identification.
i-1— Notary Public
Commission No. SZ0Z/8/q saildX3
�9/_6ETHH #WWO') 411
Name of Notary typed, printed or stamped "V!-1:3
D ilqnd /JeION
elaBinj euuqeS
SCONE OF WORK
TO INSTA? L A ROOF MOUNTED SOLAR PHOTOVOLTAIC SYSTEM AT THE OWNER RESIDENCE
LOCATED AT 39038 9TH AVE, ZEPHYRHILLS, FL 33542, USA.
THE POWER GENERATED BY THE PV SYSTEM WILL BE INTERCONNECTED WITH THE UTILITY
GRID THROUGH THE EXISTING ELECTRICAL SERVICE EQUIPMENT.
THE PV SYSTEM DOES NOT INCLUDE STORAGE BATTERIES.
EQUIPMENT SUMMARY
REQUIREGENERAL NOTES
* THESE CONSTRUCTION DOCUMENTS HAVE BEEN BASED ON FIELD INSPECTIONS AND
OTHER INFORMATION AVAILABLE AT THE TIME. ACTUAL FIELD CONDITIONS MAY
PERMITS,MODIFICATIONS
* CONTRACTOR SHALL FURNISH ALL LABOR, MATERIAL, EQUIPMENT, TOOLS, OBTAIN ALL
CONDITIONS,* CONTRACTOR HAS THE FULL RESPONSIBILITY TO CHECK AND VERIFY ALL DIMENSIONS
AND EXISTING DISCREPANCIES REPORTED
CONSULTATIONBEFORE PROCEEDING WITH THE WORK, ANY WORK STARTED BEFORE
ACCEPTANCE BY THE ENGINEER SHALL BE THE SOLE RESPONSIBILITY OF THE
CONTRACTOR AND SHALL SUBJECT ADDITIONAL
DAMAGE
ETC. SHALL BE REPAIRED TO THE ORIGINAL CONDITION OR REPLACED BY THE
CONTRACTOR AT NO ADDITIONAL COST.
* THE CONTRACTOR SHALL BE HELD RESPONSIBLE FOR THE PROPER INSTALLATION AND
COMPLETION OF THE WORK WITH APPROVED MATERIALS.
CONTRACTOR
fi OBTAIN
* ALL WORKMANSHIP PERMIT IS PROPERLY DISPLAYED,
WITH THE REQUIREMENTS OF THE FLORIDA BUILDING CODE, THE DEPARTMENT OF
ENVIRONMENTAL PROTECTION AND ALL PERTINENT AGENCIES,
* IT IS ESSENTIAL THAT ALL WORK PROCEED WITH THE MAXIMUM COOPERATION OF ALL
PARTIES AND WITH MINIMUM INTERFERENCE TO THE OCCUPANTS WITHIN THE BUILDING,
THE OWNER'S DIRECTIONS IN THIS REGARD SHALL BE FULLY COMPLIED WITH.
* THE CONTRACTOR SHALL PERFORM THE WORK IN STRICT CONFORMANCE WITH THE
LOCAL LAWS, REGULATIONS AND THE NATIONAL ELECTRIC CODE.
* THE CONTRACTOR SHALL OBTAIN ALL PERMITS, APPROVALS, AFFIDAVITS, CERTIFICATIONS,
ETC, AND PAY ALL FEES AS REQUIRED BY THE LOCAL AUTHORITIES.
* CONTRACTORS SHALL OBTAIN FIRE CERTIF. UPON COMPLETION OF WORK.
NOTES
ELECTRICAL
CONDUCTORS• ALL EQUIPMENT TO BE LISTED BY UL OR OTHER NRTL, AND LABELED FOR ITS APPLICATION.
•
• WIRING, CONDUIT, AND RACEWAYS MOUNTED ON ROOFTOPS SHALL BE ROUTED DIRECTLY
TO, AND LOCATED AS CLOSE AS POSSIBLE TO THE NEAREST RIDGE, HIP, OR VALLEY,
• WORKING CLEARANCES AROUND ALL NEW AND EXISTING ELECTRICAL EQUIPMENT SHALL
COMPLY WITH NEC 110.26
• WHERE SIZES OF JUNCTION BOXES, RACEWAYS, AND CONDUITS ARE NOT SPECIFIED, THE
CONTRACTOR SHALL SIZE THEM O.
MODULE• ALL WIRE TERMINATIONS SHALL BE APPROPRIATELY LABELED AND READILY VISIBLE.
• MODULEM i MODULE
SUPPORT RAIL, PER THE GROUNDING CLIP MANUFACTURERS INSTRUCTION.
• MODULE SUPPORT RAIL SHALL BE BONDED TO THE MODULE
GOVERNING CODES
2018 NFPA 1 (FIRE CODE)
2020 NATIONAL ELECTRICAL CODE
Trevor
2023 FLORIDA BUILDING CODE (8TH EDITION) �
2023 FLORIDA FIRE PREVENTION CODE (8TH EDITION)
FLORIDA ADMINISTRATIVE CODE(FAC)
AHJ NAME: ZEPHYRI HILL S CITY
WIRING AND CONDUIT NOTES
. ALL CONDUIT SIZES AND TYPES SHALL BE LISTED FOR ITS PURPOSE AND
APPROVAL FOR THE SITE APPLICATIONS
+ ALL PV CABLES AND HOMERUN FIRES BE #10AWG "USE-2, PV WIRE, OR
PROPRIETARY SOLAR CABLING SPECIFIED BY MFR, OR EQUIVALENT, ROUTED TO
SOURCE CIRCUIT COMBINER BOXES AS REQUIRED
® ALL PV DC CONDUCTORS IN CONDUIT EXPOSED TO SUNLIGHT SHALL BE
SYSTEM RATING
DEBATED ACCORDING TO AS PER LATEST NEC CODE.
11.745 kWDC
• EXPOSED ROOF PV DC CONDUCTORS SHALL BE USE-2, 90°C RATED, WET AND UV
8.700 kWAC
RESISTANT, AND UL LISTED RATED FOR 60OV, UV RATED SPIRAL WRAP SHALL BE
USED TO PROTECT WIRE FROM SHARP EDGES
SHEETINDEX
• PHASE AND NEUTRAL CONDUCTORS SHALL BE DUAL RATED THHN/THWN-2
INSULATED, 90°C RATED, WET AND UV RESISTANT, RATED FOR 1000V AS PER
PV1
COVER PAGE
APPLICABLE NEC
PV2
SITE PLAN
® 4-WIRE DELTA CONNECTED SYSTEMS HAVE THE PHASE WITH THE HIGHER
PV3
ROOF FLAN
VOLTAGE TO GROUND MARKED ORANGE OR IDENTIFIED BY OTHER EFFECTIVE
MEANS
PV4
STRING LAYOUT & BOM
• ALL SOURCE CIRCUITS SHALL HAVE INDIVIDUAL SOURCE CIRCUIT PROTECTION
PV5-PV6
ATTACHMENT DETAILS
® VOLTAGE DROP LIMITED TO 2%
PV7
ELECTRICAL LINE & CALCS.
• AC CONDUCTORS >4AWG COLOR CODED OR MARKED: PHASE A OR L1- BLACK,
PV8
SPECIFICATIONS & NOTES
PHASE B OR 1-2- RED, PHASE C OR 1-3- BLUE, NEUTRAL- WHITE/GRAY
PV9-PV10
SIGNAGE
PV11-PV15
EQUIPMENT SPECIFICATIONS
VICINITY MAP SCALE: NTS
1334 SRITTMOORE RD
SUITE 2310, HOUSTON, TX
77043, USA
PH#: (832) 621-0806
SYSTEM INFO
(29) Q CELLS
Q.PEAK DUO BLK ML G10.A+405
(29) ENPHASE
IQ8PLUS-72-2-US (240V)
DC SYSTEM SIZE: 11.745 kWDC
AC SYSTEM SIZE: 8.740 kWAC
METER:4425053
REVISIONS
DESCRIPTION DATE REV
P , hssaller specialift
NABCEP BADGE
PVIS - 012223-013581
PROJECT DAME & ADDRESS
CV
tti
O
NLL
J
U) - to
U cj
0 cl 0
t C � C( coI
LU Z
I.LICC w
w
w CL
Lii
co cr-
cf) M
O
0)
DATE:1124/2024
SHEET NAME
COVER
SHEET SIZE
ANSI
11° X 17"
SHEET NUMBER
SITE NOTES
* A LADDER SHALL BE IN PLACE FOR INSPECTION IN COMPLIANCE WITH OSHA REGULATIONS.
® THE PV MODULES ARE CONSIDERED NON-COMBUSTIBLE AND THIS SYSTEM IS AN UTILITY INTERACTIVE SYSTEM WITH NO STORAGE BATTERIES,
* THE SOLAR PV INSTALLATION SHALL NOT OBSTRUCT ANY PLUMBING, MECHANICAL, OR BUILDING ROOF VENTS,
* PROPER ACCESS AND WORKING CLEARANCE AROUND EXISTING AND PROPOSED ELECTRICAL EQUIPMENT WILL BE PROVIDED AS PER SECTION [NEC 110,261
!LEGEND
(N) JUNCTION BOX
(E) UTILITY METER
(E) MAIN SERVICE PANEL
�(N) ENPHASE JQ COMBINER
,j (N) FUSED AC D SCONNECT
VENT, ATTIC FAN (ROOF
OBSTRUCTION)
ROOF ATTACHMENT
CONDUIT
ENPHASE IDSPLUS -72-2-US (240V)
MICROINVERTER
0 CELLS O.PEAK DUO BLIP
ML-GIG.A+ 405 MODULES
K2 CROSSRAIL 44-X
TRENCH
(E) CHII
A
ruk
r
(E) DETACH (TYP.)
mmmm
9TH AV',,
A ^ FN I f'% I I lt:� OA'MJ�AIAV
I
�\4 OR Jo
\C E N
t74_1-4o. 93588
'go
SUTE"'OF
%
o %
X' 0 R ID
SIO N A I -
STRUCTURAL ONLY
01/31/2024
1334 BRITTMOORE RD
SUITE 2310, HOUSTON, TX
77043, USA
PH#: (832) 621-0806
SYSTEM INFO
(29) Q CELLS
Q.PEAK DUO BLK ML-GlO.A+ 405
(29) ENPHASE
108PLUS -72-2-US (240V)
DC SYSTEM SIZE: 11.745 kWDC
AC SYSTEM SIZE: 8-700 kWAC
METER: 4425053
r--------------
mREVISIONS
DESCRIPTION
v
pli h5talter specialfiv
PVIS - 012223-013581
PROJECT NAME & ADDRESS
Cif
cy)
0
<
N
cy)
q
0
C6
_j
LLJ
0
W
<
(r
U)
ro
—0
CL :3
W
(1)
W
0
>
ELI
W
CC
N
w o Z
>
Lj
>
cr W
ED Z
m
z
<
< 0
_T
w
_r
F-
0
z 0-
m
uj
co
co
Q:
co
L_
cl)
F
DATE: 1/24/2024
SHEET NAME
SITE PLAN
SHEET SIZE
ANSI B
11 " X 17"
SHEET NUMBER
PV-2
SCALE 1/16"= V-0"
10 0
METER NO#: 4425053
DESIGN SPECIFICATION
MODULE TYPE, DIMENSIONS & WEIGHT
INVERTER SPECIFICATIONS
RISK CATEGORY:
RISK CATEGORY'
11
I I
NUMBER OF MODULE&
29 MODULES
MANUFACTURER/ ENPHASE IQ8PLLJS -72-2-US (240V)
CONSTRUCTION,
SFD
TYPE;
0 CELLS Q.PEAK _DUO ELK
MODEL
ZONING:
Z I
RESIDENTIAL
S
ML-GlO,A+ 405
MAX DO SHORT 15A
I
MODULE WEIGHT-
48,5 LBS
CIRCUIT CURRENT
S OW LOAD SC
SNOW LOAD (ASCE7-16):
0 PS
0 PSF
I
CONTINUOUS OUTPUT 121 A
EXPOSURE CATEGORY:
c
MODULE DIMENSIONS'
I F 74" X 41.1" = 21 A2 S
[CURRENN T
WIND SPEED (ASCE7-16):
137 MPH
UNIT WEIGHT OF AREA:
12,3 PSF
ROOF DESCRIPTION
ROOF
ROOF SOLAR RAFTER
RAFTER ROOF MATERIAL
TILT kCCESE SIZE
SPACING
#1
25' 98% 2" X 6"
24" o,c, COMP SHINGLE
#2
--257 33% 2" x 6"
24" o. c COMP SHINGLE
#3 1
12- 1 86% 1 2' x 6"
24" ox, COMP SHINGLE
ARRAY AREA & ROOF AREA CALC'S
--ROOF
# OF MODULES
ARRAY AREA (Sq. Ft)
#1
8
168,97
#2
10
211,21
11
232:3:3::::=
(TOTAL
ARRAY ARE ROOF AREA) X 100%
= (612.51/1948) X 100% = 31 A5%
LEGEND
IN) JUNCTION BOX
(E) UTILITY METER
(E) MAIN SERVICE PANEL
(N) ENPHASE IQ COMBINER
(N) FUSED AC DISCONNECT
VENT, ATTIC FAN (ROOF
OBSTRUCTION)
ROOF ATTACHMENT
CONDUIT
ENPHASE IQ8PLUS -72-2-US (240V)
MICROINVERTER
Q CELLS Q.PEAK DUO BLK
ML-GIO.A+ 405 MODULES
K2 CROSSRAIL 44-X
TRENCH
NOTE:ATTACHMENT�
SPACING @ 24" O,C,:
ROOF #1
TILT - 25'
AZIM, - 270'
9TH AVE
(E) f KONT Off PRE51DENCE
0 a 0
R0017#2
TILT - 25'
AZIM, - W
(E) 13ACK Of RESIDENCE
SCALE- 1/8"= V-0" METER NO#: 4425053
I
OR io�e'll"'
o. 93 5 8 8
STATE -OF
0.
40RID
S�O N A
STRUCTURAL ONLY
01/31/2024
1334 BRITTMOORE RD
SUITE 2310, HOUSTON, TX
77043, USA
PH#: (832) 621-0806
SYSTEM INFO
(29) 0 CELLS
O.PEAK DUO BLK ML-GIO.A+ 405
(29) ENPHASE
108PLUS -72-2-US (240V)
DC SYSTEM SIZE: 11.745 kWDC
AC SYSTEM SIZE: 8.700 kWAC
L METER: 44!!053�
REVISIONS
DESCRIPTION DATE REV
NAB'
PV In5taller speciefist
I'VIS - 012223-013581
PROJECT NAME & ADDRESS
co
co 0
LL
o
0
cry 0)
0
Z
w @) Lo
0
cn
z 5- < — __;
0:
W 7- J) =:� ca co
co
9
W
3: 0
>
!1J_
UJ N w Z
cr
>
Lij w
> Z
m
z
< < 00
LU
T_
z a-
LLI
00 cc
cr) cn
0
0)
cy)
1124120�24
DATE:I-
FSHEET
--ROOF
NAME
PLAN
SHEET SIZE
ANSI B
11 " X 17"
SHEET NUMBER
PV-3
EQUIPMENT
SOLAR PV MODULE
INVERTER
JUNCTION BOX
IQ COMBINER BOX
BILL OF MATERIALS
OTY DESCRIPTION
29 Q CELLS Q.PEAK DUO BLK ML-%10,A+ 405
29 ENPHASE IQ8PLUS-72-2-US (240V)
3 JUNCTION BOX, NEMA 3R, UL LISTED
1 E PHASE iQ COMBINER 4 W/IQ GATEWAY
(X2-IQ-AM1-240-4)
FUSED AC DISCONNECT
60A FUSED AC DISCONNECT, (2) 50A FUSES, 240V,
ATTACHMENT
K2 SPLICEFOOT XL
ATTACHMENT
K2 FLEXFLASH BUTYL i
ATTACHMENT
T-BOLT 4 HEX NUT SET
BRANCH TERMINATOR
WATER10
SPLICE KIT
MID CLAMP
END CLAMP
MODULES END CLAMPS
GROUNDING LUG
Aft
STATE OF Ao
/" a...® ...-
c qg ®gam_ hae pg�ta Yy s!g a'tNA ei
0 M Gyre:?
DN C-U$ $flew Hampshire. L=
Mason fl- tr}".cha. McGui,e.
M � i
R t h hot oh lets
Sealed 391an21324 rn ke@1�2dc,co
L anon
F
xn PGF Er ,11-0 3C
RE
'
H2DC PLLC FL CoAk 32201
ELECTRICAL ONLY
NOT AN AS BUILT DRAWING SET
SCALE: @/ "= 1-4-
f DBj C .mMODULE STRINGING
B-,
x
B-
i
,
r -
—8
B
Y
8-3
d 6
B—
I
—
1
(E) DACK Of RE51DENCE
PVIS - 012223-013581
PROJECT NAME & ADDRESS
Lo
01.1
p� �
Y V
�
0
ro
�6
V m j
Cc q co c
CL:
® mU)�co co
>
Fn >;�:0
9.L1
LL1 Cc Lij
w
<t <t Q
Ld
z 0-
i;J
L7i Lu
co
CJ3
co
DATE: 1/2412024
SHEET NAME
STRINGLAYOUT
SHEET SIZE
ANSI B
11" X 17"
(E) COMP, SHINGLE ROOF
............ @
ATTACHMENT DETAILS
'SCALE: NTS
ENLARGED VIEW OF ATTACHMENT
SCALE: NTS
imEaffew
PV ARRAY MAX 8"
ABOVE ROOF
T-BOLT & HEX NUT SET
(E) COMP, SHINGLE ROOF
2"x6" RAFTER @ 24" O.C.
M5 X 60 LAG SCREW
LAG SCREW SHALL BE SECURED TO
STRUCTURAL SUPPORT MEMBER
1 .257'MIN LAG SCREW EMBEDMENT
OR JElf}JjJ
93588
s-wt
OR ID
% NA\-
1334 BRITTMOORE RD
SUITE 2310, HOUSTON, TX
77043, USA
PH#: (832) 621-0806
SYSTEM INFO
(29) Q CELLS
Q.PEAK DUO BLK ML-GIO-A+ 405
(29) ENPHASE
IQ8PLUS -72-2-US (240V)
DC SYSTEM SIZE: 11.745 kWDC
I AD SYSTEM SIZE: 8.700 kWAC
REVISIONS
DESCRIPTION DATE REV
NAI
Pv instalIe" Specialist
PVIS - 012223-013581
PROJECT NAME & ADDRESS
Lo
cf)
0
<
N
co
-j
:D
LL
C)
0
U)
Z UJ
3: o
@) to
0
< — co _5
T- w
U) = co
ca 9
CL
< ;'
W U)
LIJ
�'-; 3: 0
> W
�Lj Cc
N
w o Z
>
Lj
>
CC w
co Z
<
< 0
Lu
z 0-
LJ
w
cy)
CD
co
0)
cy)
DATE: 1/24/2024
w
al
JE
w
I 1 a 1 3 1 4 1 5 1 6 1 7 1
REVISION HISTDRY PRWRIETARY AND C[DfMNTI#L
FMWIW o IN m WAWK is TK W pouTf I
t.Fikf a AS
a I m I u
I
-x 4418 -XL
Im
TS
91
Cl
d
9
Joy°��
E°
�m
o. 35 � � � � NIVO LLC
1334 BRITTMOORE RD
x SUITE 2310, HOUSTON, TX
77043, USA
,Y NA,TE F
PH# : (832) 621-0806
1 ', SYSTEMINFO
�m`sas13la
�00a { (29) Q CELLS
{{ �� Q.PEAK DUO BLK ML-GIO.A+ 405
/O1m ��yl
�/7i179I991ii0� (29)ENPHASE
IQ8PLUS-72-2-US (240V)
STRUCTURAL ONLY DO SYSTEM SIZE: 11.745 kWDC
I J' �'�� AO SYSTEM SIZE: 8.700 kWAO
METER: 4425053
REVISIONS
DESCRIPTION DATE REV
i
3
� f
i
4 PV h5talIas speeciafi5t
NABCEP BADGE
PVIS - 012223-013581
PROJECT NAME & ADDRESS
C\
Lo
i°)
c+a 0
a
N i r
LL _ R-
® u
Z LUco
{ �#
I� <
co
CL
Lli> � �Z
LLJ cc LLI CC w
< <0
z Q i
co Ir
co
co
®ATE �/24�2Q2�
SHEET TAME
ATTACHMENT
TAILS
SHEET SIZE
ANSI
B
a" t8-ry "
SHEET NUMBER
`TONDUIT
OF
TERMINATOR CAPS INSTALLED owEND OF CABLE
JUNCTION BOX
CIRCULT PERCENT
PRODUCTION CT'S
34,90%
7 OR ='u � T CONT, MAX, BASE DEBATED LENGTH TAGE
FACTOR FILL CURRENT CURRENT AMP_ AMPDROP
FACTOR
COPPER
OPPER
15-21
__
' | { ._�
1������ --� |
. `
~L �------- `(N) ENPHASE IQ COMBINER
AC
NEMA 3R.mLISTED
09 38 6 5FT4 l,'07%
5 09A 4386A 165,00AI 62,40A T ;IFT
,E) MAIN SERVICE
PANEL, 100A RATED,
TO
UTILITY
__I
(E) BI-DIRECTIONAL UTILITY
4425053
IPMETER#
I
(E) MAIN BREAKER TO
POINT OF
INTERCONNECTION
SUPPLY SIDE TAP
EXISTING GROUND
SUPPLEMENTAL
t'ONNECT
ELECTRODE
GROUNDING ROD
CONDUCTOR
WITH
BONDING JUMPER
NOTES APPENDIX (AS APPLICABLE FOR TDBEBUILT DRAWING SETB): (A) TOTAL AC VOLTAGE DROP NOT TOEXCEED 2&TOINTERCONNECTION, < 3% FROM
|NVERTER(8)T3UTILITY TRANSFORMER. R375CRATEDJC)ALLC0NDUCT0RSC0PPER,UNLESSOTHERVY)BEN0TED,(D)(}UTQOORECN|M0ENT
NEMA3R. (E)ALL CONDUCTORS MUST BE PROTECTED FROM ACCESS BY AFENCE OR SUITABLE COVER, OR OUT OF REACH. (F)PROPERTY LINES, BOUNDARIES AND
ALL OTHER EXTER0MEA
SUREMENTS (G)NOPVC ALLOWED
ONROOF DR|NATTIC. (H) MC4 CONNECTORS MAY NOT BE JOINED WITH WC4 COMPATIBLEt CONNECTORS, (1) TAP CONNECTIONS IN PANEL MUST NOT VIOLATE
CONDITIONS OF ACCEPTABILITY FROM PANEL MANUFACTURER'S NRTL LISTING, OR FIELD LABEL REQUIRED, (J) PV WIRES MAY NOT BE LAID DIRECTLY ON ROOF, (K)
TY WRAPS FOR WIRE MANAGEMENT MUST BE STRUCTURAL (S21) UL APPROVED, OR EQUAL. (L) DRAWINGS ARE DIAGRAMMATIC AND INDICATE GENERAL
ARRANGEMENT OFSYSTEMS AND WORK. CONDUIT ROUTING, WHEN INDICATED, DOES NOT SHOW ALL OFFSETS, DROPS, AND RISES OF RUNS. (M) BURIED
CONDUITS UNDER AREAS SUBJECT TOVEHICLE TRAFFIC REQUIRE MIN 24''COVER, (W)NK8-B{}RPAPER INSULATED CONDUCTORS MAY NOT BEUSED EXTERIOR. (0)
THE DEVELOPER |S REQUIRED TO CONFIRM EXISTING ELECTRICAL SERVICE SIZE FROM THE UTILITY, AND MAY NOT RELY SOLELY ON EXISTING BREAKER SIZES. (P)
CONNECTING TO UTILITY EQUIPMENT REQUIRES PRIOR UTILITY CONSENT, (Q) WHEN BUILDING PV SYSTEMS WITH POWER LINE COMMUNICATIONS FOR RSD
SOLUTIONS, FOLLOWING MANUFACTURERS INSTRUCTIONS ON CONDUCTOR AND CONDUIT SPACING ISPARAMOUNT, 0RHAZARD MAY RESULT. (R)NOTIFY
ELECTRICAL ENGINEER WHO'S SEAL IS ON THIS DRAWING PRIOR TO ANY AND ALL CHANGES IN DESIGN,
`
STATE OF
H2DC PLLC FL CoA#:32201
ELECTRICAL ONLY
NOT ANASBUILT DRAWING SET
SYSTEM RATING
SERVICE INFO
UTILITY PROVIDER:
DUKEENERGY
AHJ NAME:
ZEPHYRHILE -CITY
MAIN SERVICE VOLTAGE:
MAIN SERVICE PANEL:
240V
100 A
MAIN BREAKER RATING:
100A
SERVICE FEED SOURCE:
JOVERHEAD
1oo*
77043, USA
SYSTEMINFO
SUITE 2310, HOUSTON, TX
SYSTEM SIZE: 11.745 kWD7
PROJECT NAME & ADDRESS
Lo
co
LL
Co cr
cl) co
CD
OS
co
SHEET NAME
ELECTRICAL
___7
SHEET SIZE
F
NS
SHEET NUMBER
����
o�^
'
SOLAR MODULE SPECIFICATIONS
MANUFACTURER / MODEL
O CELLS Q.PEAK DUO BLK ML-GlO.A+ 405
VMP
37.85 V
IMP
10,7 A
VOC
45,09 V
ISC
11 A 9 A
TEMP, COEFF, VOC
-0.270/o/K
PTO RATING
378.3 W
MODULE DIMENSION
74"(L) x 41.1"(W)
PANEL WATTAGE
4�}51tV
INVERTER SPECIFICATIONS
MANUFACTURER / MODEL
ENPHASE IQ8PLUS-72-2-US (240V)
MAX DC SHORT CIRCUIT CURRENT
15 A
CONTINUOUS OUTPUT CURRENT
1,21 A
AMBIENT TEMPERATURE SPECS
RECORD LOW TEMP
-1°C
AMBIENT TEMP (HIGH TEMP 2%)
33°C
CONDUIT HEIGHT
7/8"
ROOF TOP TEMP
90°C
CONDUCTOR TEMPERATURE RATE
55°C
MODULE TEMPERATURE COEFFICIENT OF VOIC
-027%/K
PERCENT OF VALUES
NUMBER OF CURRENT CARRYING
CONDUCTORS IN EMT
0.80
4-6
0,70
7-9
0.50
10-20
FOR BRANCH CIRCUIT #1 OF 10 IQ8PLUS MICROS, THE VOLTAGE RISE OIL THE 240 VAC O CABLE IS 0.46%
FOR BRANCH CIRCUIT #2 OF 10 IO3PLUS MICROS, THE VOLTAGE RISE OIL THE 240 VAC Q CABLE IS 0.46%
FOR BRANCH CIRCUIT #3 OF 9 IO3PLUS MICROS, THE VOLTAGE RISE ON THE 240 VAC Q CABLE IS 0.38%
JUNCTIONVOLTAGE RISE FROM THE BOX TO THE 1 # COMBINER
VRISE = (AMPS/INVERTER X NUMBER OF INVERTERS) X (RESISTANCE IN OHMS/FT.) X (2-WAY WIRE LENGTH IN FT.)
= (1.21 AMP X 10) X (0.00129 OHMS/FT) X (54 FT X 2)
= 12.10 AMPS X 0.00129 OHMS/FT) X 108 FT
= 1.69 VOLTS
%VRISE = 1.69 VOLTS - 240 VOLTS = 0.70%
THE VOLTAGE RISE FROM THE JUNCTION BOX TO THE IO COMBINER BOX 4 IS 0.70%
VOLTAGE RISE FROM THE 10 COMBINER BOX 4 TO THE FUSED AC DISCONNECT
VRISE = (AMPS/INVERTER X NUMBER OF INVERTERS) X (RESISTANCE IN OHMS/FT.) X (2-WAY WIRE LENGTH IN FT.)
= (121 AMP X 29) X (0.00051 OHMS/FT) X (5 FT X 2)
= 35.09 AMPS X 0,00051 OHMS/FT) X 10 FT
= 0.18 VOLTS
%VRISE = 0.1 8 VOLTS = 240 VOLTS = 0.07%
THE VOLT -AGE RISE FROM THE IQ COMBINER BOXyy4 TO THE FUSED AC DISCONNECT IS 0.07%
DISCONNECTVOLTAGE RISE FROM THE FUSED AC
VRISE = (AMPS/INVERTER X NUMBER OF INVERTERS) X (RESISTANCE IN OHMS/FT.) X (2-WAY WIRE LENGTH IN FT.)
= (1.21 AMP X 29) X (0.00051 OHM S/FT) X (5 FT X 2)
= 35.09 AMPS X 0.00051 OHMS/FT) X 10 F
= 0.18 VOLTS
%VRISE = 0.13 VOLTS - 240 VOLTS = 0.07%
THE VOLTAGE RISE FROM THE FUSED AC DISCONNECT TO THE MSP IS 0.07%
TOTAL SYSTEM VOLTAGE RISE FOR ALL WIRE SECTIONS
0.46% + 0,7% 10.0%% + 0.07%- 1.30°/4 y�
STATE OF
T
sealed 30jan2024 mike,@h2dc.com
H2DC PLLC FL CoA#; 32201
ELECTRICAL ONLY
NOT AN AS BUILT DRAWING SET
1334 BRI7TMOORE RD
SUITE 2310, HOUSTON, TX
77043, USA
PH# : (832) 621-0806
SYSTEM INFO
(29) Q CELLS
C.PEAK Duo BLK ML-G10.A+405
(29) ENPH°tSE
IQ8PLUS-72-2-US (240V)
DC SYSTEM SIZE: 11.745 kWDC
I AC SYSTEM SIZE: 8.700 kWAC
METER: 4425053
PV installer Spsciai?zi
PVIS - 012223-013581
PROJECT NAME & ADDRESS
C\
2i
co
<
Y
LL l v
Q O
�
zoj
0
c� r @) Lo
Cc nc
� co �
9 I-�<Z
>W
N oZ
ILI
IL; T ICI
<
I
z
< 0
u
= a�
n
O cc
co
DATE: 1 /24/2024
SHEET NAME
SPECIFICATIONS
MOTES
SHEET SIZE
ANSI
11" X 17"
El mem"'m Elm
RAIN SERVICE DISCONNECT/AC DISCONNECT
PER CODE- NEC 690.54
LABEL LOCATION:
INVERTER AT OR WITHIN 3'OF THE DO COMBINER SWITCH
PER CODE: NEC 690.56(C)(3)
LABEL LOCATION:
POINT OF INTERCONNECTION
PER CODE: NEC 2017, 705A2(B)
CONDUIT
PER CODE: 2017 NEC 690,31 (G)(3)
SHUTDOWN S
TO THE'OFF'
POSITION TO SHUT
DOWN THE ENTIRE
PV SYSTEM
LABEL LOCATION:
AC DISCONNECT
PER CODE: NEC 690.56(C)(1) & NFPA 11.1.12.2.1.1.1.1 &
I I . 12,2,1,4
LABEL LOCATION:
SUB PANEL OR BACKUP LOADS PANEL,
BATTERY, INVERTER OUTPUT PANEL, MAIN
SERVICE PANEL, METER/ MAIN & PV AC
DISCONNECT
Note *'ARNING labels m.,st resemble fc-=,at
,n exampie above wish over -sized WARNING,
cokx S. et"
tI It, I /I/" / - / ,
S TE Cf� - :Atz
TAI
S
sealed 30jan2O24 mike@h2dc.com
H2DC PLLC FL CoA#: 32201
ELECTRICAL ONLY
NOT AN AS BUILT DRAWING SET
ADHESIVE FASTENED SIGNS
* THE LABEL SHALL BE SUITABLE FOR THE
ENVIRONMENT WHERE IT IS INSTALLED.
* WHERE REQUIRED ELSEWHERE IN THIS CODE, ALL
FIELD APPLIED LABELS, WARNING AND MARKINGS
SHOULD COMPLY WITH ANSI 2535.4 [NEC 110.21 (B)
FIELD MARKING].
* ADHESIVE FASTENED SIGNS MAY BE ACCEPTABLE IF
PROPERLY ADHERED. VINYL SIGNS SHALL BE WEATHER
RESISTANT [IFC 605.11.1.31
1334 BRITTMOORE RD
SUITE 2310, HOUSTON, TX
77043, USA
PH#: (832) 621-0806
INFO
(29) 0 CELLS
DUO BLK SAL-GIO.A+ 405
(29) ENPHASE
JQ8PLUS -72-2-US (240V)
DC SYSTEM SIZE: 11.745 kWDC
AC SYSTEM SIZE: 8.700 kWAC
REVISIONS
--DESCRIPTION DATE REV
NAB('-''11 . . . .. . P
PV kirtafter speciaf;'5t
PVIS - 012223-013581
PROJECT NAME & ADDRESS
0
N
cy)
LL
C3
0
U)
T
UJ
to
0
0
0
Z
cl:
LO
0 ca
CC
LU
>- < --j
:r 00 U) =4 M
M
0
CL :5 < 7;
>
UJ
N
0
w Z
Lij
cf:
ui
cc w
>
ui
>
<
< M Z
0
L11
a_
uj
00
cc
co
cy)
DATE: 1/24/2024
SHEET NAME
SIGNSGE
SHEET SIZE
ANSI B
11 " X 17"
SHEET NUMBER
PV-9
STATC OF
sealed 30jan2024 mike@h2dc.com
H2DC PLLC FL CoAt 32201
ELECTRICAL ONLY
NOT AN AS BUILT DRAWING SET
FOR ALL ELECTRIC POWER PRODUCTION SOURCES CAPABLE OF BEING INTERCONNECTED
(PER CODE: NEC 70510)
1334 BRITTMOORE RD
SUITE 2310, HOUSTON, TX
77043, USA
PH#: (832) 621-0806
'29'a CELLS
0-PEAK DUO BL K ML-G1 O-A+ 405
(29) EN S� PHASE
S
U
108PLUS -72-2-US (24OV)
P � S 0�")
108P 72-2
SIZ 11 5
M SIZE: 11 .745 kWDC
DC SYSTEM
TEM
FD �� C A SYSTEM
SIZE:
8 00 kW
C
C SYSTEM SIZE: 8.700 kWAC
L !LLER-' 4425053
REVISIONS
DESCRIPTION DATE REV
I b' J
Pv Instakr swiplisT �
PROJECT NAME & ADDRESS
CV
cy)
N
cy)
LL
O
U)
Z
3:
0
LLJ
@ Lo
0
rn —
Z cy)
Cr
LIJ X U) co 00
0
co
LIJ
CD W > 0
>
w
UJ N Z
w
cf:
5;
uj T W
> Z
ui
z
<co
< 0
w
2: 0
a: z a-
0) Lu
co 0�
O cf) co
cr)
E=�12024
E 1124
F
T
SHEET:NAME
IGNAGE
S Sl
4 SHEET SIZE
ANSI B
SMEETNUM8
PV-10
THE IDEAL SOLUTION FOR:
Engineered m GermanV
Now
H-,M. 0 CELLS Air .. is
C-9 CELLS
NIVO LLC
1334 BRITTMOORE RD
SUITE 2310, HOUSTON, TX
77043, USA
PH#: (832) 621-0806
SYSTEM INFO
(29) 0 CELLS
Q.PEAK DUO BLK M3-G10.A+- 405
1Q8PLUS -72-2-US (240V)
DC SYSTEM SIZE: 11.745 kWDC
AC SYSTEM SIZE: 8.700 WAD
REVISIONS
DESCRIPTION DATE REV
p'v Installer speciafiv,
PVIS - 012223-013581
PROJECT NAME & ADDRESS
Lo
co
co
u-
0
C15 T
Z
Lij
T- (aj Lo
0
z
LU
cc 0 co
>- < — -j
CC
0
U) in co
co
:D �
m
U)
L11 5 3: 0
>
Lu
W
Cc:
N w o Z
>
Lj CC ui
> C'o Z
w
< < 0
w
z a_
0) Lu
co m
m cc
0
m
cy)
DATE. 1/24/2024
SH NAME
EQU
SHEET SIZE
ANSI B
CIENPHASE
Ow neer--st, rQ8 Vic roinver ter a are ths mdustry's first mimg6d-farrning, sciftwaredefrred
rvilcroinverzeis omh split-phars proser coolvemon cappbily to coovea DC pcmc, lo, AC
p;rvier eftionOir T'ne vrajn of the aw rropne!ary
applicatic-nop-e-Ida .leg5atedckcuft (As a--r Wh""h, ambk�s tlse miucimertef tc operatern
gfid-beidl or of modea. TN, chiis buft is advanced 55na, tcohridogy wvhfhf��, spc
digria!'rs,-4irsndh" and%iidsverit5,,, a4eviat,,irg
M
Pa, t of th.e Erphaze Ens,rgy Svote,M 08
`-efs mc;, oinve1arrrtinpatp O,Wn the
io B-It or V0 Gal wsq a rt d the E r, Lqs: �p
App �momoring and apaIys�s soltoca-re,
corme,cl Tfvrcripwckiy andety
to
i included O-OCC-2 adapts" cahf-a
prUg-n-play MC,lconvactors.
W
108 et -es WC1 ccnl�- ters fede in
reQiabihty standafds Wrih rr,�ra thal i One
ad mr-arranty of up te, 25 years.
a
areU, listed
tars PV RapA SHAdown, Eqwpm-.,nt to
coH,,,m wfthvar.rrus negwations, when
irrs,aged accc-�dina w manufacture's
it sstfucu nm,
Easy to install
rJghvWe-,ghT and cr)(f9acl 'Wh pi"re
,slaat, conr"actors
Powe,. Urre
bet, ieen C-orrip'nents
�aster msl.alfatirin With simple two -W1-
cAidir,c)
High Productivity and reliability
• Pmdu c 0 P'- W far a v an nor V g T � i 5
s1sevr"
•Moft- thir, ore, mflL�O,, cum-ulative bours
of rcstior;
Ciars 11 enciosurs
Optjvrsd fcr "he at.rt hkgh-poweered
pv nomhaes
Carn;ces vMh the larrest ari"vampd grid
support"
pelmote autol-1rat ic up"ates for tille,
grr'd requlrements
C��nfiguratde To soppol t a "Mrie, rangs,
Meel--CAR 21WI-1741-WandlEEc
15472018 04 1-741-SB TEd,)
K)s
o"
3�— lee
202�'-o 27
and IQ8+ Microi
commoo U&od f"le
235 - 440
54, ce�i i 10F ce��,
60 21) �Jf F. -cF 172 ha' ir
sl "'d e r1pa, e b, r/
&D - c, r f ',, 2 4 -
�i
Cei asd
72 1.3y 144 haif--If
W-PT "o-mage "i'age
V
211-37
27-45
IF - 'tia
m As, 5-, PiA 0 C `t-ftaa,
V
5a
R0
Max,
A,
iCt
22
M., ir,pjt C11;
A
7a
20
Dc P�-o
DC ;ref backci,d -,emm
0
I T =,gmu oeca,ay. NsDI; idWrgect ,c,, AC-%p -2 QA re,
peai, ornpjl pow.,
VA
2,45
300
ma ,, contm-Isms c,;,pv- -wer
VA
24r,
290
Nomraj 1-0 vorcrq, / rxige-
V
24C2-1- 2e4
Max
A
121
No,ni,,ai
'Ir
T&,a; hamsHl dist.,U,1-
0 1,otage -iass AC p,
ii
C ,efts t,coi,foor
cq
0,5d-tiol towfactor
0 1�5 oMsV siJi5 iagging
P-k sffto-y
JT7
`F1 -'ght-d
N-t pv,�- f cc;n,, wnp,
60
Amb"em temp*,fazwe iarxje
-4X--' 6CM 1,40'F to 1401f)
Pr - mrge
Dc urn ",sea a- type
W r VV s 1))
"'12 m,'6Z' -r m,A , 30 2 nnm 0 2')
3�00, kg r,2,36
Na'01.1 -.cio1-7,s
pp'n"od fcv cs
Y.S
--.g-
Eri.kr're
en".-n. I.Ieugcy I UN -p—'erate-j
Typ
"Ns pmdct m cL Listed ss PV Rais'd $hriadcr�,fqviomi'mad C."fa-"With NEC Zn4, NEC 2(,t7, nd NEC 2020 aW,2 a d Q221-20'8
P,,.Ao 64-Zal Papid Shulzdorv,,at PV for AC Z-j V-�� cov%tict&fs, wha,.M manFactwer'g rn su,�L: n,�.
2022-.✓,2%
1334 BRITTMOORE RD
SUITE 2310, HOUSTON, TX
77043, USA
PH#: (832) 621-0806
SYSTEM INFO
(29) Q CELLS
O-PEAK DUO BLK ML-GIGA+ 405
(2'9) ENP ASE
' 108PLUS -72-2-US (24OV)
0 LUS - - US OV)
D SYSTEM
SIZE:
1 5
C SYSTEM SIZE: 11 �745 kWDC
C M I W
SYSTEM
S 00 kW
C
AC ESYSTEM SIZE: 8-700 kWAC
M SIZE
8
M T 05
METER: 4425053
REVISIONS
DESCRIPTION DATE REV
t
PV
L-��NABOCJEP BARGE
p
Piiirj� S 0 58
PVIS - 0122�23�-013581
PROJECT NAME & ADDRESS
LO
co
N
m
-j
ILL
0
u
(D
W
0
LO
Z
W U) co OD
0
>
0
W N W0 Z
114
>
Cc 1.1i C� LIJ
> m Z
LIJ
;7
< < 0
T 0 m
ui
z a_
uj
co
co
0
G)
CY)
SHEET NAME
EQUIPMENT
SPECIFICATION
SHEET
SHEET SIZE
ANSIj'B
NS
11 " X 17"
1 1 X
m
En i) rl, a.,;e>,, e,
'I
A Q Combiner 4114C
X--IQ-AMl-240-4
X-lQ,--AMl-240-4C
&J'altu
T u tearn mcre a- bout E rApha s A- raf f enng s. wsft gnphaw com
Sim a r t
,ludes var' rur"na�v',7, aner
indt:,ne�i Enohaoe 'Aou,le Connect Inod el"i
M'c 6-�;p Ot' rnly yl' FQ
Co�,b;ne- FIC"
mcludcs, Fnatch, KI alfe",
lcsthe�'FF�s a'd
i Fe
A4- ep� a�dbi.e fF'1 2"
Um oes
zed F-t
—;d"
por"t bstl-m" bac, a,-d sdw ent-v
uded W -in' S"-eake-
KA lc"'--'� PV FF� smfdQe
Re�iab�cl
T P'Na vtirsiab rb er!pm ,pr�wgra,'
"'---FcW for ttllth 'he 0 mbm.. SK"J's
JL iFs"ed,
n,ENPHASE
.J
Enphase IQ Combiner 4/4C
XA'3DEL NUMBER
tX40-AW1,2s.,4a!
.AR.,'e.
24-
-4�zFc�d 'Iac�e V,
Ml
ACCESSOPBES AND REPLACEMENT PARTS
(Ffot nck Je-d, order seoaro'Wyj
A'ScIr"W" 'C'MUTAM"canons KA
-c"' art i- LUVIDT/Ev 101 w,V-, 5 yo Sp,t d4z, P.iar, or
T art SP,05
4G badl LTE-Ml ce,,lVav' r'FjJenFwAh 15-rew Splr�l� d1na p4an
E
4G ba'ser- 1"TE fAl' cifk4a,n, yw"' 5-pw d'v'a p0ar,
r F, F, "I-/-- �-;"
o-taksI E4'r-"' '3""Qns
2
fill ftolo7vI5."rF, b"I'm', mm
ELECTRICAL SPECIFICATfONS
t:Aoll' BR sEln"n lot'rg
12t A
May,
e4 A
92 Al
pnl
C T
a Ir,',
MECHANICAL DATA
ilill'�F Fro,
37 5%, "sY IS 5, ?5 63 r rMt rg Fe
-Cf
V,
xga✓ A tc
'Jwu A I "d-
Z�Fc" gy'�-Id
Tc2COO xiolsms f6/56cl feet"
iNTERNET CONNECTiON OPTIONS
4ed IF,
rw�
C
COMPUANCE
2 5
ENPHASE
I o- k-arn More Enphase offewigs, Visft
er0bas-4,W-M
1334 BRITTMOORE RD
SUITE 2310, HOUSTON, TX
77043, USA
PH#: (832) 621-0806
(29) Q CELLS
Q.PEAK DUO BLK ML-Gl O.A+ 405
(29) ENPHASE
108PLUS -72-2-US (240V)
DO SYSTEM SIZE: 11.745 kWDC
AC SYSTEM SIZE: 8.700 kWAC
METER: 4425053
REVISIONS
DESCRIPTIONREV
,-I "JABL-17""All
PVIS - 0 12223-013581
PROJECT NAME & ADDRESS
C\i
't
cy)
0
<
N
-j
—
0
0t
M I
-j
DO
UJ
LO
0 wz
<
0�
0
U)
00 CD
co
Ww U)
W
> 0
> W
CC
N
w 5 Z
LLf
cc: w
>
w
>
<
00 Z
< 0
LLJ
zpp
2:
0 M
dJ
I--
0')
z a-
w
rr
M
Cf)
DATE: 1/24/2024
SHEET NAME
EQUIPMENT
SPECIFICATIONS
SHEE I SIZE -
ANSI B
�wl
BE
10
We support PV systems
Formerly Everest Solar Systems 0�
Splice Foot XL
PcOnt Pending
Code cornpfiaflva UL 2703
We support PV systems
Formerly Everest Solar Systems O�
n
.. ..............
'71
1334 BRITTMOORE RD
SUITE 2310, HOUSTON, TX
77043, USA
PH#: (832) 621-0806
SYSTEMiNFO
(29) 0 CELLS
Q.PEAK DUO BLK NIL-G10.A+ 405
(29) ENPHASE
IQ8PLUS -72-2-US (240V)
DO SYSTEM SIZE: 11,745 kWDC
AC SYSTEM SIZE: 8,700 kWAC
METER: 4425053
REVISIONS
DESCRIPTION DATE REV I
PV Installer speciefis"
PROJECT NAME & ADDRESS
C\i
fy)
co 0
N
:D LL
0 C15 9'
U) —j (0
z
3: -T @ 10
cr- 0 < Z M
Cr LLJ a: w M 00
co 0 a- :5 <
Uj U) LIJ
w 0
> W N 0 Z
III CE Uj rL w
> > ca Z
Lij < < 0
z 0 a: I
w Z CL
w
cf:
of) co
coDATE: ��24f2t724
SHEET NAME
EQUIPMENT
SPECIFICATIONS
SHEET SIZE
ANSI B
ET NUM F SH�EBER P _1 �ER
PV-1 4
We support PV systems
Formerly Everest Solar Systems A—
Finisof Dark Anodized
Sectional Properties
011490 493 [3,3785 crn3j
9,q050 in2 [1,0287 cr-r,2
Notes:
Structural values ard span. &arts determined in accordaice with Mumilnum Design ManuW and AS 7-16
UL2703 Lised Systern for Fire and Bonding
NIV(;LL,C
1334 BRITTMOORE RD
SUITE 2310, HOUSTON, TX
77043, USA
PH# : (832) 621-0806
SYSTEMINFO
(29)0 CELLS
Q.PEAK DUO BLK ML-G10.A+ 405
(29) ENPHASE
108PLUS -72-2-US (240V)
Do SYSTEM SIZE: 11.745 kWDC
AC SYSTEM SIZE: 8.700 kWAC
REVISIONS
DESCRIPTION WEE REV
PViS - 012223-013581
PROJECT NAME & ADDRESS
C\T
0
N
LL
0
0 U�
U) -i
0
@) 1-0
CC 0
r- LLJ a: (0 =� CD Co
co —0 �
LIJ W W 2i 0
> W N W 0Z
Lj Cc
�Lij Crr W
> > M Z
L1.1 < < 0
z 0 X
W Z CL
W
co rr
CY) co
co
DATE: 1/24/2024
SHEET NAME
EQUIPMENT
SPECIFICATION
SHEET SIZE
ANSI B
11 " X 17"
SHEET NUMBER
PV-1 5