HomeMy WebLinkAbout91-1246
STATE OF FLORIDA
City of Zephyrhills
PASCO COUNTY
Permit N~
1246 /3
6T.so /<'-;OD
Type of Permit /--..)
~LD~ ~LEC~ PL~
Property Owners Name: K u tLT fVl < (, O~t3J;L
Job Address: 3qi{/7 tjt/.. A-vl2. 2efh'frJ,;/{~
Legal Description: Sub.Div.
BUILDING DEPARTMENT
1-813-788-6611
Date /- 3o-Q I
MEC~
FL. 3'})L{O
Lot
Blk.
Zoning CI:
Description of Work
P\O()~ (\ J.!t+", D "" -o~Ac.~ 0 f fIo0}1!
Ktc ~~ /f7:<t ~ ,}~O At//-
Energy Code Readout: ~
II2-Lto-QI ~
Complete Plans, specificalions and Fee M 51 Accompany Applical;on
?fA
(cQ~ 6-2J
Estimated Cost: 0 0"7r"b" CJ[)
Fee: 5S5.g9 ~
SIGNATURE .Li..4' )It
COMPANY
ADDRESS
TELEPHONE #
All work shal! be performed in accordance
with the above and all City Codes
and Ordinances,
OCCUPATIONAL LICENSE # C>Wt\J1ifi-
Ftr.
Pre SLB
Lintel A '_ A
FRM. 1--rL7"."W ~~
Insul.CL
WL
SLB
Tub Set
Water
Sewer
Final
Tp.Serv,
Rough In z,. 2.2,-<7/ ~
Meter Can
Const. Pole
Pool
Pre-Meter
Final
AL
Breakers
Ducts Ins
Compres or
Final
Driveway
Relnspections: When extra inspection trips are necessary due to anyone of the following reasons, a charge of ten (SIO.oo)
dollars shall be made for each trip.
(a) Wrong Address
(b) Condemned work resulting from faulty construction
(c) Repairs or corrections not made when inspection called for
(d) Work not ready for inspection when called.
The payment of reinspection fees shall be made before any further permits will be issued to the person owning same.
FORM 1000-C-91
SMALL ADDITIONS
AND RENOVATIONS
FLORIDA ENERGY EFFICIENCY CODE
FOR BUILDING CONSTRUCTION
Section 10 - Residential Prescriptive Compliance Method
Department of Community Affairs
Climate .Z5?!les
CENTRA'(Y 5 6
COMPLIANCE WITH SECTION 10 OF THE FLORIDA ENERGY EFFICIENCY CODE MAY BE DEMONSTRATED BY USE OF FORM 1 OOOC-91FOR ADDITIONS OF 600 SOU~RE FEET OR LESS, AND RENOVATIONS
TO SINGLE AND MULTIFAMILY RESIDENCES, ALTERNATIVE METHODS ARE PROVIDED FOR ADDITIONS BY USE OF FORM 1000A-91 or 9OOA-91
BUILDER: .... + /'III. G:. e.. b eo
PERMITTING ...:z.. {V L L) ')),... CLIMATE 4
OFFICE: C"-"/ r 'I -" ZONE:
:~~~IT ~ ~~~SDICTION
PROJECT NAME
AND ADDRESS:
[3'sD6D
~
OWNER:
ADDITION
IF MULTIFAMILY, NUMBER OF
UNITS COVERED BY
THIS SUBMITTAL [I]]
CONDITIONED ~2 /, SO
FLOOR AREA ~ FT
PREDOMINANT rn ~
EAVE OVERHANG Z C> FT
~NmH .
PORCH OVERHANG 102 t=l
LENGTH ~.~ FT
SINGLE
PANE
DOUBLE
PANE
NEW GLASS AREA AND TYPE
CLEAR T1NT.FILM.50LAR SCREEN
~ SO SINGLE [JJJJ SO
~ FT PANE FT
JTT::I.J3 SO DOUBLE- [JJJJ SO
~ FT P~NE FT
FLOOR TYPE AND INSULATION
WOOD MASONRY
RAISE~ ~ [II D RAISE~ = m.D
COM~O~ [[I. D COM~O~ rno
SLAB,ON _ rn D
GRADE, R - .
~
MULTIFAMILY ATTACHED D
SINGLE-FAMILY DETACHED D
RENOVATION
lill%
WALL TYPE AND INSULATION
WOOD FRAME MASONRY
EXTER~O~ [ill]. ~ EXTE~O~ OJ.D
ADJAC:~ rn. D ADJA~E~T OJ. D
COMMRO~ rn. D COM~O~: DJ.D
CEILING TYPE AND INSULATION
FOR ADDITIONS ONLY:
PERCENTAGE
OF GLASS
TO FLOOR
UNDER ~TTIC:
Ro
SINGLE ASSEMBLY
R =
~.~
OJ.D
R= m.D
COMMON:
DUCTS COOLING SYSTEM HEA TlNG SYSTEM HOT WATER SYSTEM
IN D CENTRAL D NONE D ELECTRIC STRIP D HEAT PUMP D ELECTRIC D SOLAR
UNCONDITIONED
SPACE: R = D ROOM D NATURAL GAS D ROOM I PTHP D NATURAL GAS D HEAT RECOVERY
m1la] D PTAC D OTHER FUELS D NONE D OTHER FUELS D OED, HEAT PUMP
IN CONDITIONED ~ NO NEW SYSTEM ~ NO NEW SYSTEM ~ NO NEW .m SF/EF = D.CD
SPACE: R = OJ.D COPIHSPFIAFUE =D.r-TJ SYSTEM EF c
OJ.D SEER/EER = CD
NUMBER OF BEDROOMS =
OATE
l/~tJ/91
,
I/E"/f /
, I
ReVIew of plans and speclficallons covered by thIS calculation indIcates compliance with
the Florida Energy Code. Before~, truC~j~~OIl1Pleted. thiS building will be Inspected
lor compliance In accordance rlh sectIO/~8 F,S ~
BUILDING OFFICIAL ' ~./ r 1 Jl -( A ..(' .... (
--=~
I
Cr/
Code
OWNER AGENT'
DATE
DATE
,7
TABLE 10AI MINIMUM REQUIREMENTS FOR All PACKAGES
COMPONENTS SECTION REQUIREMENTS CHE~K
WINDOWS 904,1 Minimum of 0,34 CFM per linear foot of operable sash crack (includes sliding glass doors), V/
EXTERIOR & 904,1 Maximum of 0,5 CFM per sq, It, of door area: solid core, wood panel, insulated or glass doors only, /
ADJACENT DOORS
EXTERIOR 904,1 To be caulked, gasketed, weatherstripped or otherwise sealed, /'
JOINTS & CRACKS
SOLE & TOP 903,2 Sole plates and penetrations through top plates of exterior walls must be sealed, /
PLATES
INFILTRATION 903,2 Infiltration barrier must be installed in exterior walls & raised wood floors, /'
BARRIER
INTERIOR 903,2 All openings in interior surtaces of ceilings and exterior walls must be sealed. /
JOINTS/CRACKS
FIREPLACES 903,2 Fireplaces must have flue dampers, glass doors and outside combustion air intakes,
EXHAUST FANS 903,2 Exhaust fans vented to unconditioned space shall have dampers, except for combustion
devices with integral exhaust ductwork,
WATER HEATERS 904,2 Comply with efficiency requirements in Table 9,7A, Switch or clearly marked circuit breaker (electric)
or cutoff (gas) must be provided, External or built-in heat trap required,
SWIMMING 904,3 Spas & heated pools must have covers (except solar heated), Non,commercial pools must have a
POOLS & SPAS pump timer. Gas spa & pool heaters must have minimum thermal efficiency of 78%.
HOT WATER 904.4 Insulation is required only for recirculating systems, including heat recovery units, In such cases,
PIPES piping heat loss shall be limited to a maximum of 17,5 BTUH per linear foot of pipe,
SHOWER HEADS 904,5 Water flow must be restricted to no more than 3 gallons per minute at 80 PSIG,
HVAC DUCT 904,6 All ducts, fittings, mechanical equipment and plenum chambers shall be mechanically attached,
CONSTRUCTION, sealed, insulated and installed in accordance with the criteria of Section 904,6, Ducts in unconditioned /'
INSULATION & space and air handlers located in attics must be insulated to a minimum R,4,2 (R'6 alter 1/1/92),
INST ALLA TION
HV AC CONTROLS 904,7 Separate readily accessible manual or automatic thermostat for each system,
RENOVATIONS 1003,0 Meets the requirements of see, 1003,0, See step 3 of page 2 of this form,
ONLY GLASS
-1,
CLIMATE ZONES 4 5 6
TABLE 10B, Prescriptive Requirements for Small Additions (600 Sq.Ft. and Less) and for Renovations to Existing Buildings.
EQUIPMENT MINIMUM INSTAllED
EFFICIENCY EFFICIENCY
1991 1992
...J
0 Central NC SEER = 9.0 10.0 SEER =
0 -
() Room unit or PT AC EER = 8.5 8,5 EER
=
~ Electric Resistance ANY
z
i= Heat Pump HSPF = 6,4 6.8 HSPF
<( = -
W
I Room unit or PTHP COP = 2.6 2,7 HSPFI =
w HSPF = 6.1 6.1 COP -
()
<( Gas, natural or propane
c.. AFUE = .70 ,78 AFUE =
rJ) -
Fuel Oil AFUE = ,76 .78 AFUE =
II:
w Electric Resistance EF = .88 EF =
!;( -
3: Gas, natural or propane EF = ,54 EF =
I- -
0
I Fuel Oil EF = .54 EF =
COMPONENT MINIMUM INSULATION
INSULATION INSTALLED
Conc rete R,S V
!3 Wood frame, 2' x 4' R-1l
..... Wood frame. 2' x 6' R-19
; Common, Wood frame' R,11
Common. Masonry' R-3
<I) Under attic R-30 /
CI
:z Single assembly R-19
:::::;
W Common, Wood frame' R-11
u
<I) Slab-on-g rade No Minimum V"
ex: Raised wood R-1l
0
9 Raised concrete R-S
... Common, Wood frame' R,ll
U In unconditioned space 1991 1992 /
~ R-4.2 R-6
c In conditioned soace No Minimum
'Common components are those which separate two conditioned living units in a multifamily building,
TABLE 10C. Prescriptive Requirements for Glass Areas in ADDITIONS ONLY (Renovations see 3 below)
Maximum percentage glass to floor area allowed is selected by type, overhang length, and shading coefficient. See below, Maximum Installed
%= 3~ %=
GLASS TYPE, OVERHANG, AND SHADING COEFFICIENT (TINTING) REQUIRED FOR GLASS PERCENTAGE ALLOWED
UP TO 20% UP TO 30% UP TO 40% UP TO 50%
Single Double Single Double Single Double Single Double
OH - SC OH - SC OH - SC OH - se OH - se OH - se OH - se OH - se
l' - 1,0 0' - ,90 2' - 1,0 l' - ,90 3' - 1,0 2' - ,90 4' - 1.0 3' - ,90
3' - .86
0' - ,86 l' - ,86 0' - ,70 2' - ,86 l' - .70 2' - ,65 2' - .70
0' - ,65 l' - ,65 0' - ,50 l' - .45 l' - ,50
0' - .45 0' - .35 0' - ,40
Shading coefficients (Se) may be obtained from the manufacturer of the glass, Typical shading coefficients are: single-paned clear
se = 1,0, double-paned clear se = ,90, and single-paned tint se = ,86,
Form 1000C may be used to comply the following types of construction
SMALL ADDITIONS TO EXISTING RESI DENCES. Additions which have 600 square feet or less of conditioned area may comply with the Energy Code using this form. The prescriptive
requirements in Tables 10A, 10B and 1 OC apply only to the components of the addition, not to the existing building, Space heating, cooling, and water heating equipment efficiency levels must
be met only when equipment is installed specifically to serve the addition or is being installed in conjunction with the addition construction Components separating unconditioned spaces from
conditioned spaces must meet the prescribed minimum insulation levels
RENOVATIONS. Residential buildings undergoing renovations costing more than 30% of the assessed value of the building must comply with the Energy Code using this form, The
prescriptive requirements in Tables 10A and 10B apply only to the components and equipment being renovated or replaced,
GENERAL DIRECTIONS:
1, On the left side oITable 1 OB in the column titled "INSULATION INSTAllED", indicate the R-value of the insulation being added to each component. On the right side of Table 10B indicate the
efficiency levels of the equipment being installed in the column titled "EFFICIENCY INSTAllED", All R-values and efficiencies installed must meet or exceed the minimum values prescribed
in the preceding column for that component. Components and equipment neither being added nor renovated may be left blank,
2, ADDITIONS ONLY. Determine the percentage of new glass to conditioned floor area in the addition as fOllOWS. Total the areas of all glass windows, sliding glass doors and glass panels in
doors which are more than V3 of the area of the door. Double the area of all non. vertical roof glass and add it to the previous total. When glass in existing exterior walls is being removed or
enclosed by the addition, an amount equal to the total area of this glass may be subtracted from the total glass area, Divide the adjusted glass area total by the conditioned floor area of the
addition, Multiply by 100 togetthe percent. Find the largest glass percentage under which your calculated percentage failS on Table 1 OC. For example, 29% glass would qualify for the "Up to
30%" column Prescriptives are given by the type of glass (Single or Double pane) and the overhang (OH) paired with a shading coefficient (SC), Any pair within the selected "Up To "
category is acceptable. For a given glass type and overhang, the maximum shading coefficient allowed is specified. Indicate the category into which the percentage falls in the box at the top
titled "Maximum % = ". In the next column titled" Installed", indicate the calculated percentage of glass in the addition, Actual glass windows and doors previously in the exterior walls
of the house and being reinstalled in the addition, do not have to comply with the overhang and shading coefficient requirements on Table 1 OC, All new glass in the addition must meet the
requirements for one of the options in the glass percentage category you indicated, The overhang (OH) distance is measured perpendicularly from the face of the glass to a point directly
under the outermost edge of the overhang,
3, RENOVATIONS ONLY. Only glass areas which are being replaced as part of the renovations need to meet the following requirements, Any glass type and shading coefficient may be used
for glass areas which are under at least a two foot overhang and whose lowest edge does not extend further than 8 feet from the overhang, Glass areas being renovated that do not meet this
criteria must be either single. pane tinted, double, pane clear, or double-pane tinted.
4, Complete the information requested on the top half of page 1.
5. Read "Minimum Requirements for Small Additions and Renovations', Table 10A on page 1, and check to indicate your intention to comply with all applicable items,
6, Read, sign and date the "Owner/Agent" certification statement on page 1,
CITY OF ZEPHYRHILLS BUILDING DEPARTMENT
OWNER KURt M. Go~b~{
JOB LOCATION 391/1- ?+h Av~v\lA.-e} ~ephy~h~lls} 'P'L 335'/-0
PARCEL I. D. # L4+ /Lf, Su'-\seU ~-ro..te.Sr) PJ~ + B40 k /4) P"':re J 2. if.
SHOW ALL EXISTING & PROPOSED STRUCTURES GIVING DIMENSIONS & SETBACKS,
~,
s
" ~1(;Sfin~ t
10<3 .sh~d. :L
I-> 10' --I
I
.33, S-/
\
~, PV'opoSed
'~ AdJ;+,o,^
L8''') ~
.....,'-/ ~ 2-0'
Ex istiYld
~
2"
- I 8'-
r
2.,'
1
100/
~I
House
-.. S2-' ""-
Ex i,.ti.., 1 ,
UTILITY BUILDINGS t>v- ."e'4>
MUST SHOW SIZE & -10'- ~,.S-
~
FOUNDATION INFOR-
MATION, FRONT PROPERTY LINE
~8"
(NOTE EXAMPLES 1 & 2) STREET
1. SETBACKS FOR R1, R2 ZONING
60'
2. SETBACKS FOR R3 ZONING
60'
lor
P E-
R X
0 I
10' P S 10'
0 T
S I
E N
D G
20'
1 A'
10'
la' EXISTING 10'
PROPOSED
20'SGL FAM 30'DUPLEX
1 A.
FRONT PROPERTY LINE
FRONT PROPERTY LINE