HomeMy WebLinkAbout93-3488 BUILDING PERMIT CITY OF ZEPHYRHILLS (813) 788-6611 Permit N~ 34886 i!6~' fro ~. Property Owner: ~ Job Address: t ~y b tt~ ~ Parcel J.D. # s..:L6 -:L./'~ / ~ -0 - ;2 Y A- Zoning: Energy Co>>e: Radon Gas/) ;;..:;L. /.;>... Description of Work '-jj~~ __ 4<7~ l ~~ AY~<J-- .s -3 7-..s"tJ BUILDING t, 5...s..-o ELECTRICAL 60,~ PLUMBING Date ~-/o-9'3 .:? S; tfD MECHANICAL Sewer Conn ~.;t / Fr. tf"7:J. Water Conn: 3S--O.@ ~~ /~a~~__~ Water Meter: / 6-.5-: ~ T.I.f'.'s: .--- NO OCCUPANCY BEFORE C.O. FINAL /-.;2 (, Complete Plans, Specifications and Fee Must Accompany Application. C.O. All work shall be performed in accordance with City Codes and Ordinances. Tp. Servo Rough In 1/24~9~ ~ Meter Can 9--/0'-P FRM. Const. Pole Insul. CL Pool WL Pre-Meter 01/11/94 Sheathing Bill 11-05-~r?al Driveway 12 29 93 BOB I\) orC- 12 rJ-:' _J- - tj-I'fCt 3 a rCIt..~Le"\ REINSPECTION FEES: When extra inspection trips are necessary due to anyone of the following reasons, a charge of Fifteen and 00/100 Dollars ($15.00) shall be made for each trip for each trade: Valuation or Contract Price b7 (/OTJ.~ '" City License Registration # In State Certified License# ~//..rJ~~ J ~~ j~iPlJ ELECTRICAL /l) BUILDING a. b. c. d. e. f. g. Wrong Address Condemned work resulting from faulty construction. Repairs or corrections not made when inspection called. Work not ready for inspection when called. Permit not posted on job site. Plans not at job site. Work not accessible. DATE Ins pector .w... A .........Bi.JRGES S pecmitF~~ ~_ Slgnature_ __ __~~ Company Address Telephone# <<~ g~ (5~'?~UIL~ MECHANICAL 7'7~ PLUMBING-.s-7 SLB 927-L7,'1 M/~ Tub Set r~-$? ~ Water . 3. '13 Sewe, ~-;23 -<13 E Final Breakers Ducts Insl. / I-Z3~3 BJ> Compressor Final AI~ ~ 5'-/C).-9~ /'-d.t-py,-I The payment of inspection fees shall be made before any further permits will be issued to the person owning same. -.. -.. .-..-------.... C"L r 6T~iff- fOtIt.lb 61/'vffi-E>A,'F.$ be-. VALUATlON ~ (o7t DDe) BulLDINf:>- iluMBlf\l6 - ELELrr(l <.A L - MWlf\N ll1\L - 36. ~ Q Su i6lO~rrlL" CRE..O\T - foo. CO 7drltL PE~NlIT : 531,6"0 (Qo. 00 b"3~ "'35b"f- II 7 "2- Sq. f-r. LI VI NG ~1. ~ Jf5"O 5qL FT. OTHr:-A CONN ~c..T1orJ FI=.~ S~wM - ),2-71>,00 WA,M.- 3~- 00 c 00 ME-~ - Ihv.' 7Q-rAL: If7tt?J.eo KADvN bAS - 22-,12- Z,2J2- SfL PI: '~ANSpo~:rATlo;\J I IVlpftc..r FEE- N/A '70T/rL: APPLICATION FOR PERMIT CITY OF ZEPHYRHILLS BUILDING DEPARTMENT APPLICANT G. r.. STEVE CONS'T'Rnr.'T'TON ADDRESS 177~n ~TAnF~ TN - 7FPUYRUTTT~, FT ~~~41 PHONE (813) 782 9~1(12 OWNER AN~~n~y & AMM PWTDiNTi JOB LOCATION Q~~g ~I~~ER g~a ~R, LEGAL DESCRIPTION: LOT(S) LL.!- A... LOT SIZE x AREA SQ.FT. BLOCK SUBDIVISION <:;ILu~~ O~ PARCEL I.D.f~ ~-7n-71;...17-n-7~A. WORK PROPOSED:~New Construction ----Addition ----Alteration ----Repair ____Install ____Sign/Temp. ____Sign _Move ____Demolish PROPOSED USE: ~Single Family ____M/F ____f~ of Units .-M/H ____Commercial ____Indust. ____Swim. Pool Other ____Restaurant & Health Department Approval BlfILDING SIZE: ~x 59, t.. fa. L\ "2t<1. D Square Fee t , Height RESIDENTIAL: COMMERCIAL : ATTACH (2) PLOT PLANS & (2) SETS OF BUILDING PLANS & (1) SET ENERGY FORMS.** ATTACH (3) SETS OF BUILDING PLANS & (1) SET ENERGY FORMS.** **COPY OF CONTRACT REQUIRED. PERMITS REOUESTED ~BUILDING -*-ELECTRICAL -+-MECHANI CAL -+-PLUMBING TYPE OF CONSTRUCTION: -*--Block ____Frame ____Steel FINISHED FLOOR ELEVATIONS: efi~b FT. fn' t.J $ 77 , HlO. OQ AMP Service Valuation of Total Construction ~Florida Power Corp. _W,R.E,C. $ Zk6' 0.. 00 Valuation of Mechanical Installation GAS ROOFING SPECIALTY Other Signature ****************************************** CONTRACTOR SECTION Company C.L. STEVE CONSTRUCTION State Cert, or Regist. # CB Co2213,) City License Registration # 161 ****************************************** ELECTRICIAN RTrUARn nTTFFTFT n Company . 'Z.-\.-l\u...."l. ~L~'\. ~cS:t\..V\ ~~ ~~ State Cert. or Regist. f~ c.,)Uf.,;..J...(~~ Silmatur City License Registration f~ l n **************************************** PLUMBER CURT~ RmR Company a. '5 ~ .2 ~ State Cert. or Regist. f~ C . City License Registration it ****************************************** Signature MECHANICAL Z~:L R Company gAI-I-< ~ /.&:>/...-r..... t... 6'~.s e .#k ~ ...#./ State Cert. or Regist. # CA(CC"~" V8 Signature ~ ...........'-= City License Registration it 7P-' ****************************************** j-;Vt:, OTHER Signature Company State Cert. or Regist. # City License Registration it APPLICATION ~PROVED BY PERMIT OFFICER, . CONDITIONS OF PERMIT AFFIDAVIT A. NOTICE OF DEED RESTRICTIONS The undersigned understands that this perlit 'Iay be subject to "deed restrictions" which lay be lore restrictive than City regulations. The undersigned assUles responsibility for cOlpliance with any applicable deed restrictions. B. UNLICENSED CONTRACTORS AND CONTRACTOR RESPONSIBILITIES If the owner has hired a contractor or contractors to undertake work, they lay be required to be licensed in accordance with state and local regulations. If the contractor is not licensed as required by law, both the owner and contractor lay be cited for a lisdeleanor violation under state law, If the owner Dr intended contractor are uncertain as to Khat licensing requirelents lay apply for the intended work, they are advised to contact the City of Zephyrhills Building Departlent, 18131 788-6611. Furtherlore, if the owner has hired a contractor or contractors, he is advised to have the contractorlsl sign portions of the "Contractor Sections" of this application for which they will be responsible. If you, as the owner sign as the contractor, you are indicating that you, rather than the contractor, are responsible for the work, If the contractor wishes you to sign as contractor that lay be an indication that he is not properly licensed and is not entitled to perlitting privileges in the City of Zephyrhills. C. TRANSPORTATION IMPACT FEES AND UTILITY CONNECTION FEES D. CONSTRUCTION LIEN LAW (CHAPTER 713, FLORIDA STATUTES, AS AMENDED) I certify that I, the applicant, have been provided with a copy of "Florida's Construction Lien Law - HOleowner's Protection Guide" prepared by the Florida Departlent of Agriculture and Consuler Affairs. If the applicant is sOleone other than the "owner", I certify that I have obtained a copy of the above described doculent and prolise in good faith to deliver it to the "owner" prior to cOllencelent. E. CONTRACTOR'S/OWNER'S AFFIDAVIT I certify that all the inforlation in this application is accurate and that all work will be done in cOlpliance with all applicable laws regulating construction, zoning, and land developlent. Application is hereby lade to obtain a perlit to do work and installation as indicated. I certify that no work or installation has COllenced prior to issuance of a perlit and that all work will be perforled to leet standards of all laws regulating construction, City codes, zoning regulations, and land developlent regulations in the jurisdiction. I also certify that I understand that the regulations of other governlental agencies lay apply to the intended wort, and that it is IY responsibility to identify what actions I lust take to be in co.pliance. Such agencies include but are not li.ited to: f Depart.ent of Environlental ReQulation - Cypress Bayheads, Wetland Areas and Environ.entally Sensitive Lands, Water/Wastewater Treat.ent f Southwest Florida Water KanaQe.ent District - Wells, Cypress Bayheads, Wetland Areas, Altering Watercourses f Ar.y Corps of EnQineers - Seawalls, Docks, Navigable Waterways f Depart.ent of Health & Rehabilitative Services. Environ.ental Health Unit - Wells, Wastewater Treatlent, Septic Tanks f US Environlental Protection AQency - Asbestos abatelent I also certify that, if fill laterial is tD be used in Flood Zone "A" or "A,etc,", it is understood that a drainage plan addressing a "colpensating volule" will be sublitted which is prepared by a professional engineer registered in the State of Florida prior to pertit issuance. A perlit issued shall be construed to be a license to proceed with the work and not as authority to violate, cancel alter, or set aside any provisions of the technical codes, nor shall issuance of a perlit prevent the Building Official frol thereafter requiring a correction of errors in plans, construction, or violations of any code. Every perlit issued shall becole invalid unless the work authorized by such perlit is CDltenced within six lonths of issuance, Dr if work authorized by the perlit is suspended or abandoned for a period of six lonths after the tile the work is COllenced, One 90 day extension of tile, lay be allowed for the pertit with fee charge of $15.00. The extension shall be requested in writing to the Building Official. An approved inspection lust be logged during each six lonth period, or the project will be considered abandoned. WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF CO"KENCEKENT KAY RESULT IN YOUR PAYING TWICE FOR IKPROVEKENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COKKENCEKENT. JOBS UNDER $2,500 IN VALUE DO NOT NEED TO RECORD AND POST A "NOTICE OF COKKENCEKENT". /?~ J-/- U~~)?J,/ /U?C~~ SIGNATURE: OWNER OR AGENT STATE OF FLORIDA tl ' COUNTY OF f:t!~e.o The fC1rego i ng instrument ras acknowledged before me this St;pr Z,\C, 19Qa. by Aft . m .f,. . Il~ who is personall known to me or who has produced "- as identification and' who did/did not ta~~'na~ . (1~ (~'nature) U J>ANf\- "',. Q,1e.1la. (Name Typed, Printed or Stamped) NOTARY PUBLIC ""UU~'lI" DANA Ii. EtA CD"':., ~ f*. .h '''f."j. ' MY COMMISS1Ofl.ec301855 ~ ~ ~ . . July 14.1987 . BONDED THRU 11lOY fAlllINS\IIANGI.ItlC. ~ V , ~~v-z Ie; . L - .5TEYtZ C {)";;~T. SIGNATURE: CONTRACTOR STATE Of FLORIDA C'\ COUHTY OF \.......~ . The foregc.ing i~stT~ument was acknowledged befc1re me this ~. 9 , 19 q3 by -p-€~ A 4J. STev who is personally r who has produced as identification and who did/~i8 npt take an oath. (Signat~)f\ (Name Typed, rinted NOTARY PUBLI C 1<<(((((((((((((<.(<.( <<.<.<.<<.<.<.<.(((((((((((((((((((((S. ,I ~t-t.Y ""#. MARY L. CROOK ~ . c .. ~1'> Notary Public, State of Florida ) : ~"i Commission No. CC 28681S ~ ': ~'F f\.~ My Commission Expires Sl16l91 ) C Iaaded Throuab FIL NoIary Servlc:e I< IIoodiaa Co. ~ 0>>>>>>>>>>>"'>>>>"'>>"'>>"'''''''>>''>>>>>',] ,. "c.: ~~~ \E~-. .,1- , ~ .-.'-~:' ">t \. ....:... "f'-E' Dep8rt~ent of Community Affairs FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Residential Component Prescriptive Method A :BUILDER: :PERMITTING :OFFICE: :PERMIT NO. FORM' 600A-93 PROJECT NAME: AND ADDRESS: OWNER: 1. New construction or addition 2. Single family detached or Multifamily attached 3. If Multifamily-No. of units 4. If Multifamily, is this a worst case (yes/no) 5. Conditioned floor area (sq.ft.) 6. Predominant eave overhang (ft.) 7. Porch overhang length (ft.) 8. Glass area and type: a. Clear Glass b. Tint, film or solar screen 9. Floor type and insulation: a. Slab on grade (R-value, perimeter) 10.Net Wall type area and insulation: a. Exterior: 1. Concrete (Insulation R-value) a. Adjacent: 2. Wood frame (Insulation R-value) 11.Ceiling type area and insulation: a. Under attic (Insulation R-value) 12,Air distribution systems a. Ducts (Insulation + Location) 13.Cooling system 14,Heating System: 15.Hot water system: 16.Hot Water Credits: (HR-Heat Recovery, DHP-Dedicated Heat Pump) 17.Infiltration practice: 1, 2 or 3 18.HVAC Credits (CF-Ceiling Fan, CV-Cross vent, HF-Whole house fan, RB-Attic radiant barrier, MZ-Multizone) 19.EPI (must not exceed 100 points) a. Total As_Built points b. Total Base points SN: -6251 CENTRAL :CLIMATE :ZONE: 4:_: 5:_: 6:_: :JURISDICTION NO. CK 1 . 2. 3 . 4. 5. 1510.00 6. 2.00 7 . 0 .00 Single Pane 8a. O.Osqft 8b .204 .7sqf1: New Construction Si ngle-F.:.mi I y o Double Pane O.OOsqft O.OOsqft 9a.R= 0.00 , 183.16 ft 10a-l R= 5.00, 1047.16sqft_ 10a-2 R=11,OO, 147.30sqft_ l1a.R=27.00 , 1510.00sqft_ 12a. R= 13. Type: 6.00, uncond Ce!ntral A/C EER: 10.00 He'a t Pump HSPF: 6.60 Electric 0.82 14. Type: 15. Type: EF: HR 16. 17, 2 18. 19. 76.88 19a. 23568,24 19b. 30655.30 --------------------------------------------------------------.----------------- ------------------------~----------------------------------~-_._---------------- I Hereby certify that the plans and specifications covered by this calcu- lation are in compliance with the Flor ida Ene~gY-:7de .~ PREPAREDBY~ ~ ~ DATE: [1 - . Review of the plans and specifications covered by this calculation indicates compliance with the Florida Energy Code. Before construction is completed this building will be inspected for compliance in accordance with Section 553.908 F.S. I hereby certify that this building is in compliance with the Florida Energy Code. OWNER/AGENT: DATE: BUILDING OFFICIAL: DATE: ***************************************************************************~*** SUMMER CALCULATIONS *****~************************************************************************* === BASE ===: === AS-BUILT === GLASS---------------- ORIEN AREA x BSPM = ------------------------------------------------------------------------------- --------_._--------------------------~---~-~----------._---------_._--------~-----~------------ I I POINTS : TYPE SC ORIEN AREA x SPIM x SOF == POINTS ------------------------------------------------------------------------------- N 52.02 82.2 4276.0 SGL TINT N 16.2 51.5 .85 710.4 SGL TINT N 3.5 51.5 .75 132.6 SGL TINT N 16.2 51.5 .85 710.4 SGL TINT N 16.2 51.5 .85 710.4 E 64.76 82.2 5323.3 SGL TINT E 16.2 107.1 .82 1419.2 SGL TINT E 16,2 107.1 .82 1419.2 SGL TINT E 16.2 107.1 .82 1419.2 SGL TINT E 16.2 107.1 .82 1419.2 S 39.37 82.2 3236.2 SGL TINT S 16.2 98.3 .72 1153.7 SGL TINT S 11.6 98.3 .72 825.9 SGL TINT S 11.6 98..3 .72 825.9 W 48.57 82.2 3992.5 SGL TINT W 16.2 107,,1 ,82 1419.2 SGL TINT W 16.2 107..1 .82 1419.2 SGL TINT W 16.2 107..1 .82 1419.2 ------------------------------------------------------------------------------- .15 x CONDo FLOOR / TOTAL GLASS = ADJ. x AREA AREA FACTOR GLASS = POINTS ADJ GL~,SS POINTS GLASS POINTS --------------------------------------------------------------.----------------- .15 1,510.00 204.72 1.106 16,827.98 18,618.30 : 15,003.30 NON GLASS------------ : AREA x BSPM = POINTS : --------------------------------------------------------------.----------------- ------------------------------------------------------------------------------- TYPE R-VALUE AREA x SPM = POINTS -------------------.------------------------------------------------------------ WALLS---------------- Ext 1047.2 1.0 1047.2 Ext NormWtBlock In 5.0 1047.2 1.00 1047.2 Adj 147.3 .7 103.1 Adj Wood Frame 11,0 147.3 .70 103.1 DOORS---------------- Ext 36.7 4.8 176.2 Ext Insulated 20.0 4.80 96.0 Ext Insulated 16.7 4.80 80,2 Adj 16.7 1.6 26.7 Adj Wood 16.7 2.40 40.1 CEILINGS------------- UA 1510.0 .6 906.0 Under Attic 27.0 1510.0 .68 1019.3 FLOORS--------------- SIb 183.2 -31.8 -5824.5 Slab-on-Grade .0 183,:2 -31.90 -5842.8 INFILTRATION--------- 1510.0 10.9 16459.0 Practice #2 1510.0 10.90 16459.0 TOTAL SUMMER POINTS : 31,511.96 : ================================================================================ TOTAL x SUM PTS ===============================================================:================ 28,005.26 SYSTEM = MULT COOLING : TOTAL POINTS : COMPON x CAP x DUCT x SYSTEM x CREDIT = COOLING RATIO MULT MULT MULT POINTS ------------------------------------------------------------------------------- 31,511.96 .37 11,659.43 : 28,005.26 1.00 1.100 .340 1.000 10,473.97 ================================================================================ ***************************************************************************~*** WINTER CALCULATIONS %~***~************************************************************************* === BASE ===: =::::= AS-BUILT ::::::::= GLASS---------------- ORIEN AREA x BWPM = I I POINTS : ='= = =:::: = ==:::::::: =::.:::::::::::: :::::::::::::::::::::::::::::::::::::::: =:::: =:::::::::::: =:::::::::::: =::. =::. =::.:::: = =,,:::::::: =::.:::: -::::-:::::::: -::::::::::.::::::::::,::::::::::::: -:::::::::::::::::::::: ::::,"'::::::::::::::::: =::. =::. =::. ::::=::.:::, =::. =::.::::::::::::::::= TYPE SC ORIEN AREA x WPI'1 x WOF ::::: POINTS N -176.9 ----------------------------------------.--------------------------------------- 52.02 -3.4 E 64.76 -3.4 -220.2 s 39.37 -3.4 -133.9 W 48.57 -3.4 -165.1 SGL TINT N 16.2 9.6 1.09 169.3 SGL TINT N 3.5 9.6 1.15 38.2 SGL TINT N 16.2 9.6 1.09 169.3 SGL TINT N 16,2 9.6 1.09 169.3 SGL TINT E 16.2 -2.0 .01 -.5 SGL TINT E 16.2 -2,0 .01 -.5 SGL TINT E 16.2 -2.0 .01 -.5 SGL TINT E 16.2 -2,,0 .01 -,5 SGL TINT S 16.2 -10..2 .77 -127.4 SGL TINT S 11.6 -10,,2 .77 -91.2 SGL TINT S 11.6 -10..2 .77 -91.2 SGL TINT W 16.2 -2..0 ,01 -.5 SGL TINT W 16.2 -2.0 .01 -.5 SGL TINT W 16.2 -2.0 ,01 -.5 ------------------------------------------------------------------------------- .15 x CONDo FLOOR / TOTAL GLASS::::: ADJ. x AREA AREA FACTOR GLASS :::: POINTS ADJ GL~ISS POINTS GLASS POINTS .15 204.72 ---_._--------------------------~----------------------------------------------- 232.99 =============================================================================== 1,510.00 NON GLASS------------ : AREA x BWPM:::: POINTS : 1.106 -696.05 -770.10 : TYPE R-VALUE AREA x WPM:::: POINTS -------------------------------------------------------------------------------- WALLS---------------- Ext 1047.2 1 .1 1151.9 Ext NormWtBlock In 5.0 1047.2 2.90 3036.8 Adj 147.3 1.8 265.1 Adj Wood Frame 11.0 147,3 1,80 265,1 DOORS---------------- Ext 36.7 5.1 187.2 Ext Insulated 20.0 5.10 102.0 Ext Insulated 16.7 5.10 85.2 Adj 16.7 4.0 66.8 Adj Wood 16.7 5.90 98.5 CEILINGS------------- UA 1510.0 .6 906.0 Under Attic 27.0 1510.0 .68 1019.3 FLOORS--------------- Slb 183.2 -1.9 -348.0 Slab-on-Grade .0 183.2 2.50 457.9 INFILTRATION--------- 1510.0 4.1 6191.0 Practice #2 1510.0 4.10 6191.0 TOTAL WINTER POINTS I I 7,649.88 : -------------------------------------------------------------------------------- --------~----------~--------------------------------------------~---------------- ---------------------------------------------------------------.---------------- -------------------------------------------------------------------------------- 11,488.74 TOTAL x WIN PTS SYSTEM MULT ::::: HEATING : TOTAL POINTS : COMPON x CAP x DUCT x SYSTEM x CREDIT = HEATING RATIO MULT MULT MULT POINTS 7,649.88 1.10 ------------------------------------------------------------------------------- 6,508.37 8,414.87 : 11,488.74 1.00 1.100 ---------------------------------------------------------------.---------------- ---------------------------------------------------------------.---------------- .515 1.000 *****~*********************************************************************~*** WATER HEATING *~***************************************************************************** === BASE ===: === AS-BUILT === NUM OF BEDRMS -----------------------------------------------.-------------------------------- -----------------------------------------------.-------.------.---------------------.-------- x MULT = TOTAL TANK VOLUME EF TANK RATIO x MULT x CREDIT MULT = TOTAL ------------------------------------------------------------------------------- 3 3527.0 10,581.00 80 .82 1.000 3785.0 .58 6,585.90 -------------------------------------------------------------.------------------ -------------------------------------------------------------------------------- ******************************************************************************* SUMMARY ******************************************************************************* === BASE === === AS-BUILT === COOLING POINTS + -------------------------------------------------------------------------------- ------------------------------------------------------------------------------- HEATING POINTS HOT WATER + POINTS = TOTAL POINTS COOLING POINTS + HEATING POINTS HOT WATER + POINTS = TOTAL POINTS ------------------------------------------------------------------------------- 11659.4 8414.9 10581.0 30,655.30 10474.0 6508.4 6585.9 23,568.24 --------------------------------------------------------------~----------------- ------------------------------------------------------------------------------- ***************** * EPI = 76.88 * ***************** For detailed information of ~he EPI rating number or for any ITEM listed, ask your Builder for DCA Form 600A-93 or Form 600B-93 ENERGY GUIDE EPI= 76.9 o 10 20 30 40 50 60 70 80 90 100 :------------------------------x----------: The maximum allowable EPI is 100. The lower the EPI the more ~efficient the home RESIDENTIAL ENERGY PERFORMANCE RATING SHEET ITEM HOME VALUE Low Efficiency High Efficiency WINDOWS.,.....,..,..,.., .... Single Tint SINGL CLR DBL TINT :------X--------------: INSULA T ION. . . . . . . . . . . . . . . . . . Ceiling R-Value.........27.0 R-l0 R-30 :-----------------X---: R-O R-7 :----------------X----: R-O R-19 :x---------------_____: Wall R-Value......", 5.7 Floor R-Value......... 0.0 AIR CONDITIONER. ............ SEER/EER. . . . . . . . . . . . . . . . .. 10.3 10.0 SEER 17.0 :X----------------____: 9.7 EER 16.0 HEATING SySTEM.............. Electric COP/HSPF........ 6,6 6.8 HSPF 12.0 :X---------------_____: 0.78 AFUE 0.90 :---------------------: Gas AFUE....,.... ... 0.00 WA TER HEA TER . . . . . . . . . . . . . . . . Electric EF...,.......... 0,82 0.88 0.96 :X---------------_____: 0.54 0.90 Gas EF , . . . . . . . . , , , .. 0 .00 --------------------- Solar EF . , . . , . . . . . . . . . 0.40 0.80 :---------------------: OTHER FEATURES.............. .. .. .. .. .. II .. .. .. .. .. .. .. .. .. .. .. .. .. II II .. .. .. .. .. .. .. I certify that these energy saving features required for the Florida Energy Code have been installed in this house, Address: Builder Signature: Date: City/Zip Florida Energy Code for Building Construction - 1993 Florida Department of Community Affairs FL-EPL CARD93 For detailed information ofi~e EPI rating number or.for any ITEM listed, ask your Builder for DCA Form 600A-93 or Form 600B-93 ENt;:RGY GUIDE EPI= 76.9 o 10 20 30 40 50 60 70 80 90 100 I-------------------___________x__________: The maximum allowable EPI is 100. The lower the EPI the more ,efficient the home RESIDENTIAL ENERGY PERFORMANCE RATING SHEET ITEM HOME VALUE Low Efficiency High Efficiency WINDOWS....,................ Single Tint SINGL CLR DBL TINT :------X--------------: INSULATION. . . . . . . . . . . . . . . . . . Ceiling R-Value.........27,O R-I0 R-30 :-----------------X---: R-O R-7 :----------------X----: R-O R-19 :X--------------______: Wall R-Value.,.....,. 5.7 Floor R-Value.....,... 0.0 AIR CONDITIONER......... .... SEER/EER. . . . . . . . . . . . . . . . ., 10.3 10.0 SEER 17.0 :X---------------_____: 9.7 EER 16.0 HEATING SySTEM.....,......,. Electric COP/HSPF... .,... 6.6 6.8 HSPF 12.0 :X---------------_____: 0.78 AFUE 0.90 1______--------------- I Gas AFUE......... ,.. 0,00 WATER HEATER......,......... Electric EF.............. 0.82 0.88 0.96 :X---------------_____: 0.54 0.90 Gas EF . . . . . . , . . . . . " 0 .00 ---------------------- Solar EF . , . . . . , . . . , , . . 0.40 1 1 .---------------------1 0.80 OTHER FEATURES..,....... .... .. II II .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. If II .. .. .. I certify that these energy saving features required for the Florida Energy Code have been installed in this house. Address: Builder Signature: Date: City/Zip Florida Energy Code for Building Construction - 1993 Florida Department of Community Affairs FL-EPL CARD93 /' ----:-'~-',.-'. --"."---~-':~-"'-"--"-":;-':~-" -","--. --c,-":""'-",,_-.t.._ _.__*_ _ ~ . .. ,~ CONTf~{'-'lC::TOR #: NAME: G. L. STEVE ADDR: 6446 SILVER OAKS CJ:~;r: Zh i LU:: ~ E N 1 R ALP E R M I r T PASCO COUIHY, FLOR I [fA T ;\l Ci DATE: (!1./21..:./94 PAGE ~ 1 OF 1 I~;:;:;UE OFFICE: D RECEIPT NUMBR= 00201362 OFFICE:. DADE CITY FOP; :34::::;::-[i CHEC:f( :f~ r ~ V ~O~O (~Ccr~T 11-'l TCHAL AMOUNT: COMPNY ACCOUNT CENTER 8450 - 363000 - ~ 46.44 AMOUNT DESCRIPTION/PERMT DATA DR/eR 46.44 ****** SOLID WASTE FEE 60 Fa:::C"E I VED BY ----__.:::_..:...__ ...:.L:...,:.......:.-4:....__,_____..,.:..:....l:.~>_~.:...____,_.__