HomeMy WebLinkAbout94-3861
BUILDING PERMIT
CITY OF ZEPHYRHILLS
(813) 788-6611
Permit N ~
386111
d-/6-7'(
,
Date
BUILDING
ELECTRICAL
PLUMBING
~A~I~ Sewer Conn
Water Conn:
:::::,~,:~e' i6ft~~--S;1~
Parcell.D. #
Water Meter:
T.I.F.'s:
Zoning:
Description of Work
Energy C~.1 A4. /~ ....0.-_ ~n Gas:
A-/C U~'(fL ~~
NO OCCUPANCY BEFORE C.O.
7~qi
1'J/
FINAL
DATE
Complete Plans, Specifications and Fee Must Accompany Application. C.O.
All work shall be performed in accordance with City Codes and Ordinances.
DATE
Inspector
City License Registration #
State Certified License#
/~
~~
Permit Fee '
Signature ().e(. 4.A'1{O
Company
Address
Valuation or
Contract Price
/?-t:.;2. crD
/
Telephone#
7e8"- J I '2-9'
BUILDING
ELECTRICAL
PLUMBING
Tp. Servo
Rough In
Meter Can
Const. Pole
Pool
Pre-Meter
Final
Breakers
Ducts Insl.
Compressor
Final
SLB
Tub Set
Water
Sewer
Final
Ftr.
Pre SLB
Lintel
FRM.
Insul. CL
WL
Driveway
REINSPECTION FEES: When extra inspection trips are necessary due to anyone of the following reasons, a
charge of Fifteen and 00/100 Dollars ($15.00) shall be made for each trip for each trade:
a. Wrong Address
b. Condemned work resulting from faulty construction.
c. Repairs or corrections not made when inspection called.
d. Work not ready for inspection when called.
e. Permit not posted on job site.
f. Plans not at job site.
g. Work not accessible.
The payment of inspection fees shall be made before any further permits will be issued to the person owning
same.
BID SPECIFICATION
Pa.ge. 1
A ~d B SERVICES o~ CENTRAL FLORIDA INC
Da.t.e.: 02/14/94
Qu.o.t.a...t.Lon.: 0008
ZEPHYRHILLS NEWS
PAUL LINDSEY
333 WEST HIGHWAY 54
lEPHYRHILLS FLORIDA 33540
T~e.phon.e.: 782-1558
DESCRIPTION:
PROPOSE TO CHANGE OUT THE EXIXTING 5 TON YORK HEAT PUMP
CONDENSING UNIT WITH A 5 TON RHEEM HEAT PUMP MODEL # RPKA060JAS
UNIT WILL BE CONNECTED TO THE EXISTING ELECTRICAL AND PIPING
SYSTEM.
MANUFACTURES WARANTEE PROVIDED IS 5 YEARS ON THE COMPRESSOR AND 1
YEAR ON THE ELECTRICAL COMPONENTS ADDITIONALY THE COMPRESSOR CAN
BE EXTENDED THROUGH THE 10TH YEAR FOR AN ADDITIONAL $150.00
EXTRA WORK TO BE INCLUDED BY INSTALLER: WE WILL SEAL DUCTING IN
THE CEILING WHERE IT IS LOOSE AND INSULATE THE SUCTION LINE FROM
THE CONDENSING UNIT TO WHERE IT PENETRATES THROUGH THE WALL. WE
WILL CLEAN THE EVAPORATER COIL AND INSURE THAT THE DRAIN IS OPEN
AND FUNCTIONING PROPERLY.
WHILE PREPAIRING OUR PROPOSAL WE FOUND THE AIR HANDLING UNIT IN
POOR CONDITION DUE TO RUST THROUGH OF THE DRAIN PAN AND OUTER
CASE THE EVAPORATER COIL IS IN BAD CONDITION AND SUPPORTS ARE
RUSTING THROUGH. IT IS OUR RECOMENDATION THAT THE AIR HANDLING
UNIT BE REPLACED IN THE NEAR FURTURE AS THIS DIRECTLY EFFECTS THE
LIFE OF THE COMPRESSOR.
WE CAN PERFORM THIS DURING THE CONDENSING UNIT CHANGE OUT FOR THE
ADDITIONAL SUM OF $1200.00
ALL MATERIAL IS GUARANTEED TO BE AS SPECIFIED AND THE ABOVE WORK
TO BE PERFORMED IN ACCORDANCE WITH DISCUSSED SPECIFICATIONS AND
COMPLETED IN A SUaSTANTIAL WORKMANLIKE MANNER FOR THE SUM OF
$1862.00
PAYMENT IS TO BE MAVE U~MPLET~ ..
RESPECTFULLY SUBMITTED. ~1 ~
DATE 2-Jt-Cf1
THE ABOVE PRICES, SPECIFICATIONS AND CONDITIONS ARE SATISFACTORY
AND ARE HEREBY ACCEPTED. YOU ARE AUTHORIZED TO DO THE WORK AS
SPECIFIEV. PAYMENT WILL B~S~TL7rEV ABOVE.
ACCEPTANCE OF PROPOSAL. ~ DATE ;;Jjlb[q,y
o