HomeMy WebLinkAbout94-4023
BUILDING PERMIT
N.O.'
Permit
C~TY OF ZEPHYRHILLS
(813) 788-6611
40236'
S-II-r(
~
:;.5
BUILDING
f)'L.>
'/
f).O
ELECTRICAL
Date
P~
MEC~sewer Conn
Water Conn:
Property Owner:
Job Address:
Parcell.D. #
~p..-.l. c:tI-eilLLAY/6
'3 Cl ~.2. q - <;? ~ {h..e..
1:1-- {J.."-~/- O~/D -////000-0570
Water Meter:
T,I.F.'s:
Zoning:
Description of Work
NO OCCUPANCY BEFORE C.O. DATE
Complete Plans, Specifications and Fee Must Accompany Application. C.O,
All work shall be performed in accordar<::,e with City Codes and Ordinances.
Permit Fee
Signature
Company
Address -
TelePhone#i/~'
, !!.-
~, 41J/C1~
Valuation or
Contract Price
" ~ 5001 ~
City License Registration # -----
State Certified License# ~
-
~
~~
PL~
-
M~'
-
Breakers
Ducts Insl.
Compressor
Final
Tp, Serv, M
Rough In ~ Jf., , Qq,
Meter Can
Const, Pole
Pool
Pre-Meter
Final tl;>- 2l:> ''1'-1 ffb
SLB
Tub Set
Water
Sewer
Final
Ftr.
Pre SLB
Lintel
FRM, c ~)&, ,6jl/&.ti
Insul. CL
WL
fj,..)fll, b -20 ,<(<-I 'BeLL
Driveway
REINSPECTION FEES: When extra inspection trips are necessary due to anyone of the following reasons, a
charge of Fifteen and 00/100 Dollars ($15,00) shall be made for each trip for each trade:
a, Wrong Address
b, Condemned work resulting from faulty construction,
c. Repairs or corrections not made when inspection called.
d. Work not ready for inspection when called.
e. Permit not posted on job site,
f. Plans not at job site.
g, Work not accessible,
The payment of inspection fees shall be made before any further permits will be issued to the person owning
same,
APPLICATION FOR PERMIT
CITY OF ZEPHYRHILLS
BUILDING DEPARTMENT
OWNER'S IfllllE~i'IL -^- ffi J221#;/l /'v \ -Z)
OWIlER'S ADDRESS3,9j/), 9:b: 4J/-f2:. ,
~(J :i3-7 ' \ ,! ~~)
JOB ADDRESS d,7 L/. .~7 // .~
PHONE /32) - /'0 z; 6
LEGAL DESCRIPTION: LOT(S)
BLOCK
SUBDIVISION
PARCEL 1. D. , ) ()... -,2 6 - J-/ - 1)3/0- IJ CJ c9 c3 6J - CJ6~ 0
WORK PROPOSED: New Construction Addition ~eration _Repair Install
_Sign
Move
Demolish
PROPOSED USE: ~ngle Family
_M/F
_' of Units
_M/H
Commercial
Indust. Swim. Pool
Other
____Restaurant & Health Department Approval
BUILDING SIZE: ~x~ Square Feet, Height
RESIDENTIAL: ATTACH (2) PLOT PLANS & (2) SETS OF BUILDING PLANS & (1) SET ENERGY FORMS.**
COMMERCIAL: ATTACH (3) SETS OF BUILDING PLANS & (1) SET ENERGY FORMS.**
**COPY OF CONTRACT REQUIRED.
~ILDING
~CTRICAL
t-MECHANICAL
LPLUMBING
TYPE OF CONSTRUCTION:
PERMITS REQUESTED
/ SUO
$ - 1_
'/
, / /) AMP Service
1 _,
,
Valuation of Total Construction
~Orida Power Corp.
_W.R.E.C.
$
Valuation of Mechanical Installation
GAS
ROOFING
~ame
SPECIALTY
Block
Steel
Other
FINISHED FLOOR ELEVATIONS:
FT.
IS PROJECT IN FLOOD ZONE AREA? ~
YES NO
******************************************
CONTRACTOR SECTION
BUILDER
COMPANY
State Cert. or Regist. ,
City License Registration'
******************************************
Signature
ELECTRICIAN
COMPANY
State Cert. or Regist. ,
City License Registration,
******************************************
Signature
PLUMBER
COMPANY
State Cert. or Regist. ,
City License Registration'
******************************************
Signature
MECHANICAL
COMPANY
State Cert. or Regist. ,
City License Registration ,
******************************************
Signature
OTHER
Signature ~h "-
COMPANY
State Cert. or Regist. ,
~ (,~l /,\"".11. y~ Ci ty License Registration #
******************************************
APPLICATION APPROVED BY
PERMIT OFFICER.
CONDITIONS OF PERMIT AFFIDAVIT
A. NOTICE OF DEED RESTRICTIONS
The undersigned understands that this perlit laY be subject to 'deed restrictions' which lay be lOre restrictive tban City
regulations. tbe undersigned assOles responsibility for cOlpliance with any applicable deed restrictions.
B. UNLICENSED CONTRACTORS AND CONTRACTOR RESPONSIBILITIES
If the owner bas hired a contractor or contractors to undertake work, they lay be required to be licensed in accordance with
state and local regulations. If the contractor is not licensed as required by lil1f, both the owner and contractor lay be
cited for a lisdeteanor violation under state law. If the owner or intended contractor are uncertain as to wbat licensing
requirelents lay apply for the intended work, they are advised to contact the City of Zephyrhills Building Departlent, (813)
788-6611.
FurtherlOre, if the ONner has hired a contractor or contractors, he is advised to have the contractor(s) sign portions of the
"Contractor Sections' of this application for wbich they will be responsible. If you, as the owner sign as the contractor,
you are indicating that you, rather than the contractor, are responsible for the work. If the contractor wisbes you to sign
as contractor that laY be an indication that be is not properly licensed and is not entitled to perlitting privileges in the
City of Zepbyrhills.
C. TRANSPORTATION IMPACT FEES AND UTILITY CONNECTION FEES
D. CONSTRUCTION LIEN LAW (CHAPTER 713, FLORIDA STATUTES, AS AMENDED)
I certify that I, the applicant, bave been provided with a copy of 'Florida's Construction Lien Law - HOIeOWDer's Protection
Guide" prepared by the Florida DepartJent of Agriculture and ConsOler Affairs. If tbe applicant is SOEone other than the
"owner", I certify that I have obtained a copy of the above described docUlent and prOllise in good faith to deliver it to the
"owner" prior to COlleDCeJent.
E. CONTRACTOR'S/OWNER'S AFFIDAVIT
I certify that all tbe inforlation in this application is accurate and that all work will be done in cOlpliance with all
applicable laws regulating construction, loning, and land develo.-ent.
Application is hereby lade to obtain a perlit to do work and installation as indicated. I certify that no work or
installation bas cOlleDced prior to issuance of a perlit and that all work will be perfoIJed to leet standards of all laws
regulating construction, City codes, zoning regulations, and land develo.-ent regulations in the jurisdiction. I also
certify that I understand that the regulations of otber goveruental agencies laY apply to the intended work, and that it is
IY responsibility to identify what actions I lust take to be in cOlpliance. Such agencies include but are not lilited to:
* Departlent of EnviroDleDtal Regulation - Cypress Baybeads, Wetland Areas and EnviroDleDtally Sensitive Lands,
Water/Wastewater treatlent
* Southwest Florida Water HanageJent District - Wells, Cypress Bayheads, Wetland Areas, Altering Watercourses
* ArlY Corps of Engineers - Seawalls, Docks, Navigable Waterways
* Departlent of Health & Rebabilitative Services, EnvirORlental Health Unit - Wells, Wastewater treatlent, Septic tanks
* US EnvirODJental Protection Agency - Asbestos abateJent
I also certify that, if fill laterial is to be used in Flood Zone 'A' or "A,etc.", it is understood that a drainage plan
addressing a 'cotpeDsating volUle" will be sublitted wbicb is prepared by a professional engineer registered in the State of
Florida prior to perlit issuance.
A perlit issued shall be construed to be a license to proceed with the work and not as authority to violate, cancel alter, or
set aside any provisions of the technical codes, nor shall issuance of a perlit prevent the Building Official frOll thereafter
requiring a correction of errors in plans, construction, or violations of any code. Every perlit issued shall becOlle invalid
unless the work authorized by such perlit is COIIeDced within sillOnths of issuance, or if work authorized by the perlit is
suspended or abandoned for a period of sillOnths after the tile the work is cOllenced. One 90 day extension of tile, laY be
allowed for the perlit with fee charge of $15.00. 'fbe extension sball be requested in writing to the Building Official. An
approved inspection lUSt be logged during each s1llOnth period, or the project will be considered abandoned.
WARNING 'f0 OWNER: YOUR FAILURE fO RECORD A NOIICH OF <XJtHEHCEHDI HAY RESUL'f IN YOUR PAYING 'filCH FOR IHPROVEHBMfS TO YOUR
PROPERlY. IF YOU IMfEND fO OBtAIN FINANCING, CONSULt WIfH YOUR LINDO OR 111 AnORREY BBFORE RECORDING YOUR HO'IICE OF
COHMENCBMEJIT. JOBS UNDER $2,500 IN VALUE 00 NOI NEBD 1'0 RECORD AND POS'f A 'NOfICB OF COHMBNCBMBJII".
SIGNA!URE: OWNER OR AGBlIT
SIGNATURE: CONfRACfOR
StATE OF FLORIDA
coum OF
The foregoing instrument was acknowledged
before me this , 19____ by
S'fA'I'B OF FLORIDA
coum OF
The foregoing instrument was acknowledged
before me this , 19_____ by
who is personally known to me or who has
produced
as identification and who did/did not
take an oath.
who is personally known to me or who has
produced
as identification and who did/did not
take an oath.
(Signature)
(Name Typed, Printed or Stamped)
NOTARY PUBLIC
(Signature)
(Name Typed, Printed or Stamped)
NOTARY PUBLIC
y4~ g~ ~--:.
*~
71- 2/ - ;;7"
~-a ~+~
7~D- 7fAvb
,
r, >) ('J
1-/ --~
r--------3----- l;i.
J-:>~ ? e
---~~
f',^ \ \ \ 5 /~
" _ c~
J-y~1~\
ILt t ~ H ~ ~ /
OO'f-
--S)
,-
--r
y.l~
1 L.oAu:- f~fJU6- ~6:c..'hou~ -kJ 5L1fB hU ,.1
~f S#ALl-Bi- ~ )ub..Jt+~ ~L-1tY~G-
~UJDOJ~ SH ~tl1 ~u!I,s-6- AND ~ J Ft'2Awtllij b-'
61414lL t..{l1vE: 1:/( 5i-p1't.~{orJ ~ G/2&~
p~ CA~::tI- ({ - 3oq. l
- J.j
7~_
I --
tl};
y. ~
+- ~lctL wi4LLS 5HtlLL..- 1I1fVfi- }V\l~tMvM Jizll' r4YU)O~)) , ' '
Dft.... o..:)~B 6~N& vv1l:tt S+~~Ui-I3o-:it ~-402.,, 3e-)- ,,,L
~,~
~f" / 'r--~
"{ fi"ISl\~ .~ t16:/6tjT SlWL. g,E. ~l: ~S r
. . ~ ~10-11\1 {,- ~ S~ oli- '10' /1'-<- lj1uJ,J li
~ of (1014i) _ . . ... ~
I
,
L, ~!
--------L-----..-:f-------l\7\----::=J
/.... .
~ ~A/
--I
CITY OF ZEPHYRBILLS BUILDING DEPARTMENT
OWNER
JOB LOCATION
PARCEL I.D. #
SHOW ALL EIISTIRG & PROPOSED S'l'RUC'l'URES GIVIJIG DIMENSIONS & SETBACKS.
4Li
ALLEYWAY ACCESS FOR
GARAGE OR CARPORT -
15 FOOT SETBACK
REQUIRED.
/
J)
7 l..-'
=-1-
\
,
,~----,-~-" ________..1
UTILITY BUILDINGS
MUST SHOW SIZE &
FOUNDATION INFOR-
MATION.
FRONT PROPERTY LINE
(NOTE EXAMPLES 1 & 2)
STREET
1. SETBACKS FOR R1, R2 ZONING
60'
2. SETBACKS FOR R3 ZONING
60'
10'
P E-
R X
0 I
10' P S 10'
0 T
S I
E N
D G
20'
1 0'
10'
10' EXISTING 10'
PROPOSED
20'SGL FAM 30 ' DUPLEX
1 0'
F.ROII'I' PROPERTY LIRE
FRONT PROPERTY LINE
y ~ IIl5llld lKl
~ 1V3S 0lSS0ll"3 ONY
I<<lU VI'IOOJNI 'HO~1l'Ill3d
1lO 03~/OD/lO
~ g"::JlK'(l SJ J.!llW~d
'~)iI QHV I<<lU VI\llOJNI TlY
'IfMlHS S311ru:>nlllS
31m ~ OlIVONV1S
a>>'.olld ~1ll33t<<lN3 3HI
S~3^OO 0110S
;; ~
~ ~~'" l7!
~::E~
CL ww'" ~
~ 15"'< IS
~<Xl
eo25
0 UWCL g
, lr9~ ,
z~ n 8~'" N
! .......
<~ ~ on'f1~ n
~~ ....""0
~, 3~
Il;lN l-
I- cr::
Vl ,,~~ 0
0 ......lil~ 0-
0- cr::
cr:: x <(
.~ < u
~ ::E
Z ~ :c
w 0
u Vl :=>
~ w 0
I- ~ cr::
:=> :c
0 > l-
F
~.
l- X
<
cr:: ::E
0 ~
0-
. 0::
<( ~
N U
. W
-'
CD
:=>
0
0
.c
~~
~~
~"~.
i~:
~
IS
e
U
~~
51~
9~
::E::E
.... I~:
Vl
~ 0 --'
0- " ;t a:: :;;:
0-
0:: ......lil;:! w
0
~
:z
w
u
:c
....
~
s
n
f
--tt-
\
g I
~I
~I
Vl~
~~ ~
-a.f5 0..
~Lo..~ 'ro")
~8< ."
t-O:: U ~
Jllru:>OlUS 1S0H
!)~.].;~L9L (t06)
6l1Zt V(JlIOlI ':IlNW1lO lllOd
1_
lNYlll\SNOO lN311d01l\3lI - lYll
~~ ~~ creJ:~
X
::I N -<it
<w :i ~::E
lil-' d
~ ~~
Vl --,0- +
\o! ~~ N 025~
~ ~ ~...g
o-E 2-~s!
C> ~-'
~ Eo- :-' \.;::~
:%: U
'" "w ~ ~~~
~ -'
0 ......::x =>
\
31:
~~
-'~
<Xl...
o-so!
C> w
~l<!
0...
-' ~
:;;: <
~ zr
~ ~~
g: f5~
g ~~
V1 ....J~
5 '~i!=
:s ~s
VI
\o!
'"
<
>
I-
0::
o
0-
0::
<(
U
:c
o
:=>
o
0::
:c
I-
:z
o
i=
u
w
Vl
':lo~
'lo.J ~ c(.......
VlO lI:lB
.=.~ 8:c
~ ~a ~g
~~l<!Eol<!
u25 !!liSt;
~WLo.. 0-<;::)
F= ~z w:::~
~ -"'l( ~<tn
Z Z CL
~ ... 0-
U CL U
"w
~ .~~
~
'"
w
CL
...
CL
~::. ~
CL~ CD
~ 0....... ,
~,., N
5 ;:30 :::-
~ ...w n
CL "
~ ~~ ~
~~ n
,'1 1O;!''lj~ VI i
~. ,~ ~....
'> ~
' >l;j
-'~
>-'
........
2)l(~
::>NO~
Nob cs
~~~ 0
3llru:ln&S lSOtt~Sll)
II'
~ ...~ I
~ ~ I'~r"'ll(: ..
... ~ Q.
o 'lila!iJe\nh
~~~~ &1~3 ~
~lI:Q:. 5i~:-t. ~
O.......O~fi!S....
.....~~~ ~..
~~~~~...lIt9
0.:0.: ':i!~
25c>~o~ ~I
~~~i~~S.i.'- ~
~-' ... O'i _
~
;; lli. 0
5- t: b
>- Je~.1
" ~C~Q""
~~ "w
~~ u i0i4~B
."," ~I.bt:'oi
NN ~:~r\.
Ii>
-'
:;;:
.~
~
~
IS~
e8
uo::
>-
l-
=:;
i=
:=>
:c
"'J
- tA\.n
~ ~~ l!l
....
0::
o
0-
0::
<(
U
w
-'
o
:z
Vi
rrJ
~~
5~
~ B0
i= W~
80a:...
~-;~ffi
of- ~ t:
~ ^ftl ~
~ :it5
:z
C> 0
Z Vi
8~ 0
... I e:i
~.-
l7!.
~.
<N
"',
8......
2
-'
-'
c(
~
I-
0::
0
0-
0:: ......
<( :::-
u
0 n
:z
c(
0
w
i7\
>-
l-
=:;
i=
:;)
Vl
~
Oili~
~WF=
IS:~......
;l<JEO'::::'
u z,
l<!............
~a~,
;:~l7!C>
~6....
..z~
~
o
z
o
:z
Vi
Vl
W
cr::
C
o
c(
Vl
-'
:;;:
I-
W
o
CD
c(
vi
.,;
" @;! ,"~
lI,~,i .."l;!'~li 'I ,: .:~
)- ~ ~ III, '''.
"'51'0"" , 't:" =
_,~ld.. ,i, ,~;.,.."
:';i.. i~; ~I. i "j
.1 Ui :-(i~~ ~
"~IIl~... ... a
. ';1;:1'" !...~ ~ ~
0', ',0
:z,.~ '",...~!Ii iii
~~, .......-3,;2
8 '~~ ~~ is i
L...... ':.,:i III
o 0 ,,~......
~;E;!2 ~.~:r lD
e
~
~
!
ARTICLE 210 - BRANCH CIRCUITS
70-45
(b) Cord Connections. A rcceptacle outlet shall be installed wherever
flexible cords with attachment plugs are used. Where flexible cords are
permitted to be permanently connected, it shall be permitted to omit recep-
tacles for such cords.
(c) Appliance Outlets. Appliance receptacle outlets installed in a dwell- I
ing unit for specific appliances, such as laundry equipment, shall be
installed within 6 feet (1.83 m) of the intended location of the appliance.
210-52. Dwelling Unit Receptacle Outlets.
(a) General Provisions. In every kitchen, family room, dining room,
living room, parlor, library, den, sun room, bedroom, recreation room, or
similar room or area of dwelling units, receptacle outlets shall be installed
so that no point along the floor line in any wall space is more than 6 feet
(1.83 m), measured horizontally, from an outlet in that space, including any
wall space 2 feet (610 mm) or more in width and the wall space occupied
by flXed panels in exterior walls, but excluding sliding panels in exterior
walls. The wall space afforded by fIxed room dividers, such as freestand-
ing har-type counters or railings, shall he included in the 6-foot (1.83-m) I
measurement.
As used in this section, a "wall space" shall be considered a wall unbro-
ken along the floor line by dOOlways, fIreplaces, and similar openings.
Each wall space 2 feet or more (610 mm or more) wide shall be treated
individually and separately from other wall spaces within the room. A wall
space shaH be permitted to include two or more walls of a room (around
corners) where unbroken at the floor line.
(FPN): The purpose of this requirement is to minimize the use of cords across
dOOlways, fireplaces, and similar openings.
Receptacle outlets shall, insofar as practicable, be spaced equal dis-
tances apart. Receptacle outlets in floors shall not be counted as part of the
required number of receptacle outlets unless located close to the wall.
The receptacle outlets required by this section shall be in addition to any
receptacle that is part of any lighting fIxture or appliance, located within
cabinets or cupboards, or located over 5V2 feet (1.68 m) above the floor.
Exception: Pennanently installed electric baseboard heaters equipped
with factory-installed receptacle outlets or outlets provided as a separate
assembly by the manufacturer shall be pennitted as the required outlet or
outlets [or the wall space utilized by such pennanently installed heaters.
Such receptacle outlets shall not be connected to the heater circuits.
(FPN): Listed baseboard heaters include instructions that may not permit their
installation below receptacle outlets,
(b) Small Appliances.
(1) The two or more 20-ampere small appliance branch circuits
required by Section 220-4(b) shall seNe all receptacle outlets, including
refrigeration equipment, in the kitchen, pantry, breakfast room, dining
room, or similar area of a dwelling unit. Such circuits, whether two or
more are used, shall have no other outlets.
Exception No.1: A receptacle installed solely for the electrical supply
to and SllppOrl of all electric clock in any of the rooms specified above.
E\"ceptioll No.2: Outdoor receptacles.
70-46
NATIONAL ELECTRICAL CODE
Exception No.3: In addition to the required receptacles specified by
Section 210-52, switched receptacles supplied from a general-purpose
branch circuit as defined in Section 210-70(a), Exception No.1 shall be
pennitted.
Exception No, 4: A receptacle sefved by a circuit supplying only motor
loads.
Exception No.5: Receptacles installed to provide power for electric
ignition systems or clock timers for gas-fired ranges, ovens, or counter-
mounted cooking ullits,
(2) Receptacles installed in the kitchen to selVe counter top surfaces
shall be supplied by not less than two small appliance branch circuits,
either or both of which shall also be permitted to supply receptacle outlets
in the kitchen and other rooms specified in Section 210-52(b )(1). Additional
small appliance branch circuits shall be permitted to supply receptacle out-
lets in the kitchen and other rooms specified in Section 210-52(b)(I).
(c) Counter Tops. In kitchens and dining areas of dwelling units, a
receptacle outlet shall he installed at each wall counter space 12 inches (305
mm) or wider. Receptacle outlets shall be installed so that no point along
the wall line is more than 24 inches (610 mm), measured horizontally from
a receptacle outlet in that space.
A receptacle outlet shall be installed at each island or peninsular counter
top with a long dimension of 24 inches (610 mm) or greater and a short
dimension of 12 inches (305 mm) or greater. Receptacle outlets to selVe
island or peninsular counter tops shall be installed above, or within 12
inches (305 mm) below the counter top. Receptacle outlets shall be
installed so that no point along the centerline of the long dimension is more
than 24 inches (610 mm), measured horizontally from a receptacle outlet in
that space. A peninsular counter top is measured from the connecting
edge.
Counter top spaces separated by range tops, refrigerators, or sinks shall
be considered as separate counter top spaces. Receptacle outlets rendered
not readily accessible by appliances fastened in place or appliances occu-
pying dedicated space shall not be considered as these reqUIred outlets.
Receptacle outlets shall not be installed in a face-up position in the work
surfaces or counter tops in a kitchen or dining area.
(FPN)~ The 24-inch (61O-mm) dimension is measured along the wall line or cen-
terline, and the intent is that there be a receptacle outlet for every 4 linear feet
(1.2 m) or fraction thereof of counter length,
(d) Bathrooms. In dwelling units, at least one wall receptacle outlet
I shall be installed in the bathroom adjacent to each basin location. See Sec-
tion 210-8(a)(I).
(e) Outdoor Outlets. For a one-family dwelling and each unit of a two-
family dwelling that is at grade level, at least one r~c cle outlet acces-
sible at grade level shall be installed at the front an ack f the dwelling. '
See Section 210-8(a)(3). ~~~ Vv...A..
(1) Laundry Areas. In dwelling units, at least one receptacle o~~ bO'\,..~.~
be installed for the laundry. ~
^ , ,
ARTICLE 210 - BRANCH CIRCUITS
70-39
210-8. Ground-Fault Circuit-Interrupter Protection for Personnel.
(a) Dwelling Units.
(1) All 125-volt, single-phase, 15- and 20-ampere receptacles
installed in hathrooms shall have ground-fault circuit-interrupter protec-
tion for personnel.
(2) All 125-volt, single-phase, 15- or 20-ampere receptacles installed in
garages shall have ground-fault circuit-interrupter protection for personnel.
Exception No.1 to (a)(2): Receptacles that are not readily accessible.
Exception No.2 to (a)(2): A single receptacle or a duplex receptacle for
two appliances located within dedicated.space'for each appliance that in
1101711al use is 110t easily moved ftvl1f one place ,to another, and that is cord-
and plug-connected in accordance with Section 400-7(a)(6), (a)(7), or (a)(8).
Receptacles installed under exceptions to Section 210-8(a)(2) shall not be
considered as meeting the requirements of Section 210-52(g).
(3) All 125-volt, single-phase, 15- and 20-ampere receptacles installed
outdoors where there is direct grade level access to the receptacles shall I
have ground-fault circuit-interrupter protection for personnel.
(FPN): See Section 215-9 for feeder protection.
For the purposes of this section, "direct grade level access" is defined
as being located not more than 6 feet, 6 inches (1.98 m) above grade level
and being readily accessible.
(4) All 125-volt, single-phase, 15- and 20-ampere receptacles installed
in crawl spaces at or below grade level and in unfinished basements shall
have ground-fault circuit-interrupter protection for personnel.
For purposes of this section, unfinished basements are defined as por-
tions or areas of the basement not intended as habitable rooms and limited
to storage areas, work areas, and the like.
Exception No.1: A single receptacle supplied by a dedicated branch
circuit that is located and identified for specific use by a cord- and plug-
connected appliance, such as a refrigerator or freezer.
Exception No.2: TIle laundry circuit as required by Sections 210-52(1)
and 220-4(c).
Exception No.3: A single receptacle supplying a pennanently installed
sump pump.
(5) All 125-volt, single-phase, 15- and 20-ampere receptacles to serve
counter top surfaces, installed within 6 feet (1.83 m) of a wet bar sink or
kitchen sink, shall have ground-fault circuit-interrupter protection for per-
sonnel.
(FPN): The intent of this subsection is to permit the exemption of receptacles
that are located specifically for appliances such as' refrigerators and freezers from
ground-fault circUlt-interrupter protection for personnel.
(6) All 125-volt, single-phase, 15- or 20:.ampere receptacles installed in
boathouses shall have ground-fault circuit-interrupter protection for
personnel.