HomeMy WebLinkAbout94-4501
BUILDING PERMIT
7R F S:S-' ()7)
CITY OF ZEPHYRHILLS
(813) 788-6611
Permit ~
450113
'I '17. 0 {;
Date I:)... -j -9' Y
BUILDING
61.:l~-
ELECTRICAL
-..S ~ --: tIZJ
PLUMBING
stY ~ t7lJ
MECHANICAL
Sewer conn~Lf=7F -frYo .6
Water Conn: Cv-'r~-d8-Y'tJ .s
pmpertyOwn". :1:-A<PXt.~7 L~+_",~4
Job Address: 0 '70 .A
Parcell.D.# .;l~C).6 -.J.I.. C;UO....I'c3CJCJt::;. CJ/-.5-~
Radon Gas: J?: IIZJ
Water Meter:
T.J.F.'s:M
i;t1t'o-Z-~-.f7V
Zoning: ~ E~Y Code:
Description of Work ~ L-~ /,Ie (/ .../~)
FINAL ,.r;-/I- 9:5
DATE
C.O. -.!1( -/ ~ -7~-
DATE
NO OCCUPANCY BEFORE C.O.
Complete Plans, Specifications and Fee Must Accompany Application.
All work shall be performed in accordance with City Codes and Ordinances.
Inspector
City License Registration # 02:J....
State Certified License#
:~;~~::,:~~
Company _ _ ')
Address
Telephone#
Valuation or
Contract Price -.5/,~"'CJ Jy', .!TV
.~~./A41 ~ d;AJ.
JJl~;. U;t:;
ELECTRICALo(7/
BUILDING
Ftr. v12-2.q~6L~ Tp. Servo
Pre SLB /2-11'1 l.~ Rough In':>~ /b-q~ tB,J....
Lintel 6)-/- Ci."J tJdlJ Meter Can I J -I-ry
FRM. . ;2:Jtr-!ISf!L Const. Pole 0 -3-'t)l~
Insul. CL Pool
. ~L:Z-L'-4_) BILl- ~ Pre-Meter I./-L{..q[ ~
"6'" H,~ 2--?-) t..,,---Final
Driveway .~-~ .QS 01 ~ () fc:.c:-r,za.. &Nv
jjlsr~i.. E~lW~ J:3L~b'! , 12--1..~t.J t31t..-~
8')" oK ~1- (<lJ'I ~
REINSPECTION FEES: When extra inspection trips are necessary due to any 0
charge of Fifteen and 00/100 Dollars ($15.00) shall be made for each trip f
13~~~b ~~
PLUMBING 91 MECHANICAL //0
SLB /2..-1/ C,4 BLLL- Breakers
Tub Set.:;)- JLi- 'i5'Jfdl Ducts Insl..:;!)'" 14"'~ J ..P~
Wat~r Compressor
Sewer~-\fJ-'i5~ Final ;;"-J~c;S t8~
Final 4-/0-93 ~ t.RJ?
a.
b.
c.
d.
e.
f.
g.
Wrong Address
Condemned work resulting from faulty construction.
Repairs or corrections not made when inspection called.
Work not ready for inspection when called.
Permit not posted on job site.
Plans not at job site.
Work not accessible.
.~
/.~ -/.-? 9'
. /
f~~-Y9S
The payment of inspection fees shall be made before any further perml
same.
e person owning
v
Department of Commuriity Affairs
FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION
Residential Component Prescriptive Method A CENTRAL
ATTACHED PATIO HOME : BUILDER: CiEI-.JERAL HOME DEVELOPhMENT CORP.
6705 BASSWOOD CIRCLE: PERMITTING!t?1iJ- : CLIMf6ITE
ZEPHYRHILLS FL 3351 OFFICE: 7~ 1 ZONE: 41' 51 1 61 I
, 1 N' 1 I _.1 I _.1 1.._1
i'1ACL.EAN :PERMIT N . '5'01/3 :JURIS,DICTION NO.~/ltOD
CK
1. New Construction
attached 2. Multi-Family
3. 0
case (yes/no) 4. No
5. 1300.00
6. 1.66
7. 1.0.33
Single Pane
8a.194.4sqft
8b. O.Osqft
F'OR-M 600A-93
PROJECT NAME:
AND ADDRESS:
OWNER:
1. New construction or addition
2. Single family detached or Multifamily
3. If Multifamily-No. of units
4. If Multifamily, is this a worst
5. Conditioned floor area (sq.ft.)
6. Predominant eave overhang (ft.)
7. Porch overhang !ength (ft.)
8. Glass area and type:
a. Clear Glass
b. Tint, film or solar screen
9. Floor type and insulation:
a. Slab on grade (R-value, perimeter)
1.0.Net Wall type area and insulation:
a. Exterior: 1.. Concrete (Insulation R-value)
a, Adjacent: 2. Wood frame (Insu!ation R-va!ue)
11.Ceiling type area and insulation:
a. Under attic (Insulation R-value)
12.Air distribution systems
a. Ducts (Insulation + Location)
1.3.Coo!ing system
14.Heating System:
15.Hot water
sy'stem:
16.Hot Water Credits: (HR-Heat Recovery,
DHP-Dedicated Heat Pump)
17.Infiltration practice: 1, 2 or 3
18.HVAC Credits (CF-Ceiling Fan, CV-Cross vent,
HF-Who!e house fan, RB-Attic radiant
barrier, MZ-Multizone)
19.EPI (must not exceed 100 points)
a. Tota! As_Bui!t points
b. Total Base points
SN: 6096
Double Pane
O.OOsqft
o . OOs~qft
9a.R= 0.00 , 149.00 ft
10a..1 R= 4.20, 872.00sqft__
10a"-2 R=11 .00, 85.00sqft__
11a.R=30.00 , 1407.00sqft____
12a. R= 6.00, uncond
13. Type: Centra! A/C
SEER: 10.00
14. Type: Heat Pump
HSPF: 7.00
15. Type: Electric
EF : 0 .90
16.
17.
18.
2
19.
19a.
19b.
89.20
21.640.86
24262.32
---------~-----------------------------------------------~------------------------_."-------
------------------------.-----------------.---------------------------------------
I Hereby certify that the plans and
specifications covered by this calcu-
lation are in compliance with the
Florida Energy Code.
.
~~~~~RED BY'.~~
Review of the plans and specifications
covered by this calculation indicates
compliance with the Florida Energy
Code. Before construction is completed
this building will be inspected for
compliance in accordance with Section
553.908 F.S.
I hereby certify that this building is
in compliance with the Florida Energy
Code.
OWNER/AGENT:
DATE:
....
~~
11-~{)-qLf
BUILDING OFFICIAL,~4~
DATE: /..::L - ( - 91-
G~ERCJ'( GU I D:= .
For detailed i~formation
of the E~I rating number
or for any ITEM listed,
ask your Builder for
DCA F-onn 600A--93
0)- F 0)- m 600B-"93
::;:PI= 139.2
o 10 20 30 40 50 60 70 80 90 100
:-----------------------------------X-----:
The maximum allowable EPI is 100. The lower the EPI the more efficient the home
RESIDENTIAL ENERGY PERFORMANCE RATING SHEET
ITEM
HOME \/ALUE
Low Efficiency
High Efficiency
WINDOWS. , . . . . . . . . . . . . . . . . . . .Si ngle Clear
SINGL CLR DBL TINT
:X--------------------:
INSULATION. . . . . . . . . . . . . . . . . .
R--10
R-30
Ceiling
R-Value......... 30.0
:--------------------x:
R--O
R--7
Wall
R--Value......... 4.8
:-------------X-------:
R-O R-19
:X--------------------:
Floor
R--Value.........O.O
AIR CONDITIONER... .... '" ...
SEER/ETR , . . . . . . . . . . . . . . . .. 10.0
10.0 SEER 17.0
: X.- - ..- >0- ---.----. -. - ..- .._- ..--- - -.. :
9.7
EER
16.0
HEATING SySTEM..............
Electric COP/HSPF........ 7.0
6.8 HSPF 12.0
:X--------------------:
0.78 AFUE 0.90
, ,
,---------------------,
Gas AFUE.....,.,.... 0.00
WATER HEATER.. ...... ..... ...
0.88
0.96
Electric EF.............. 0.90
:----X----------------:
0.54
0.90
Gas
EF..........".. 0.00
0.40
0.80
Solar
EF............. .
I . . . . . I
,---------------------,
OTHER FEATURES..............
I certify that these energy saving features required for the Florida
Energy Code have been installed in this house.
. . 0~ ..Ii r , Builder ~ ~l.' <-P In....
Address: LQ'lQl. o..x.SSUJJaG' \.A. V" _~:3ignature: ~ ~
City/Zip "2~h.;\l51 ~L)~540
Florida Energy Code 'for Building Construction - 1993
Florida Department of Community Affairs
Date: H -.JJ:J4=!
FL-EPL CARD93
l. \.. . (\
t'Y\QL LeQt\
VALUATION:
SQ. FT. LIVING:
COST/FT:
G.H.D
6705 BASSWOOD CIRCLE
$51,504.00
1,321
$35.00
SQ. FT. OTHER:
479
COST/FT:
$11.00
VALUATION
DRIVEWAY
$51,504.00
$20.00
ADDRESS
$20.00
FEE SHEET
$273.00
SQ. FT. UNDER ROOF
1,800
RADON GAS
$18.00
TRAFFIC IMPACT FEES
99%
1 %
$466.02
$461.36
$4.66
PERMIT FEES
BUILDING:
PLUMBING:
ELECTRICAL:
MECHANICAL:
SUB-TOTAL:
CREDIT:
TOTAL:
449.50
55.00
61.25
30.00
$595.75
55.00
$540.75
CONNECTION FEES PAID
ON PERMIT # 3840-B
SEWER:
WATER:
METER:
TOTAL:
0.00
0.00
0.00
$0.00
GRAND TOTAL: $1,024.77