HomeMy WebLinkAbout95-4737
BUILDING PERMIT
Permit N~
CITY OF ZEPHYRHILLS
(813) 788-6611
4737F
Date 3-j-9...l>-
BUILDING
~TRIC;V
PLUMBING
MECHANICAL
Sewer Conn
Water Conn:
::~:::,~,:nel,l5Jj7.iv~~
Parcell.D. #
Water Meter:
T.I.F.'s:
Zoning:
Description of Work
Energy Code:
7l/A-l Mf~~_
Radon Gas:
NO OCCUPANCY BEFORE C.O.
FINAL
DATE
Complete Plans, Specifications and Fee Must Accompany Application,
All work shall be performed in accordance with City Codes and Ordinances,
c.o.
DATE
Permit Fee
Signature
Compa
Address
Telephone# 15/3 - 3'-17 - CJ.17 UJ
Valuation or
Contract Price
YJ>>
City License Registration # d- 9 b
State Certified License#
"
~I
~A~;t-~
/'
BUILDING
ELECTRICAL
PLUMBING
MECHANICAL
Breakers
Ducts Insl.
Compressor
Final
SLB
Tub Set
Water
Sewer
Final
Tp. Servo
Rough In
Meter Can
Const. Pole
Pool
Pre-Meter
Final
Ftr.
Pre SLB
Lintel
FRM.
Insul. CL
WL
Driveway
REINSPECTION FEES: When extra inspection trips are necessary due to anyone of the following reasons, a
charge of Fifteen and 00/100 Dollars ($15.001 shall be made for each trip for each trade:
a. Wrong Address
b. Condemned work resulting from faulty construction.
c. Repairs or corrections not made when inspection called.
d. Work not ready for inspection when called.
e. Permit not posted on job site.
f. Plans not at job site.
g. Work not accessible.
The payment of inspection fees shall be made before any further permits will be issued to the person owning
same.
~~Lh- h'b
~_~ ~~.....-: JaIl---
-_.-
FPC Transformer
500 KVA 480V
\.AJJJ
rr(Y)
I
) 1000A C.B.
A.4 -~~_~~---------
~\
LOAD
, , ,. ---_----....~
--- - . I".!". ~~ .........4~-.___...,~
FPC Installed Equipment
I S~andbX _G=ll!r_a~o~ y~ojec:
i / Generator KWH \
i " Interface Meter I
J ------ - - - Module
_ - - I 276/120Y "
(:0~5 A i ZC-3 t~ [
\ _,_ _ ~L' 5A 600V IC=200 KA
I
Emergency
600 K)V
@
Generator
480V
:) 900A C.B.
.
Automatic
Transfe'r
Swi tch
PLANS ntVltW[O
JATF ___________.,-_______
'\ r, . 1 ,. i
Clearwater
Distribution
Engineering
ei FlorIda
. Power
~1Ia<
Standb
City of Zephyrhllls
Waste Water Treatment Plant
Zephyrhllls
, ,
I
I
I
/
"
f'PC
~ KYA
rP.ANSfO!n,lU
SIotfon #
11 ~9"'')o-0512860
l"Islet!:
is-l Radlo ~odu!a
Gar,rolor :n~.rfoc.
f./cx1'Jla
K'#H t.!.~er
E)(lemol Antenna
~
UAlH CONTROL
ROOU
~KW
G04DJ.ATOIt
q:
Ex~atl:'\\l l.!ot.r
12$61 sn
A
.....
+--- 1"1,1011 C,T:.
and PT F'\,I.I
r .....-- PT
, Cobfno1
:.....-- UPS
A
Equipment Location Sketch
Note:
Remote Alarm Module to be
in the Office Building and wired to
Radio Module thru existing underground
conduit system.
creorNoter
Distribution
Enqineerinq
.Florida
Power
C(H>(.P.A T1l:H
~... .RId
Section AA
KN>1 Veter (KNri)
Cp.~eratornter'ace .-
s-~ ,
RcC'O "'0""0' Voc... e (G \A) i '
'1/ooiJev ('5' ) ( -1 I ·
- - - - ~ - f - - - --- - .- - -- ~ - - ~ - -,' - - e- - - - - - -1,-- - -- ~.j)P<'ox
I ~~~j I ' 5'6' AD
it I IW~T'II .
'I I l ~~:.
I~ 1_
~ ~~r::r-' ~
I Vont,. ....Jr=1.......J
,.. PiC Lj'. PIC
n
W " EVT
('~
I
, IT EMTI1"
3/4" EVT
To '~ I
~ 20\i'f.C ==~
C:'ct,,'t
I
~
PT
Cobi"'et
(PiC)
ljPS
I
I
i
iQ
r,!@-=-~ '
i 0 --.,,-
r.'
i 11__ ~
,1..,( "
,
Rer1"o~e A or"1 I!OQ.; e
eRNA)
.. P~T
I
~o C""s 0"'0
::Ii COr"roc:"o'1S
Eqillpmenl Installation Detail
Stand b
City of Zephyrhills
Waste Water Treatment Plant
Zephyrhills. FL
0:: 0::
~~~
"'"' 0 .- ("4
~ .-N",,"tIOU)"l'OOl.-.-.-
I I
~ ~ ) 'H C
:21~) j ( I
W
<1> J-!:
,.
it
00
'-" '-"
System PONer Source
" UPS
Neutral
'- 120 VAC
<2>
<2>
~
<120 w; N> 1 .....__
<>llJl'RJL. N> 2 ~ :;
<\u-l> 3 ~
<\U~ 4 ~~
(\Ut-2> 5 ~ ~
- -
~-3> 6 J~
18-1 7 0::0
R d. 8 0=0
a 10 9 0:0
Controll0 0::0
Module 11 0=0
.ost) 12.Q32.
l
FPC Installed Equipment -.----- -r-------------J. ""
: Connections Internal To
3- Element I Existing Control Cubicle
13-Terminal I
KWH Meter :
(MTR) !
rr =.- N ~ .- 0 N 0 ~ 0 0 i
II a..a..a..oooouoa.. j
i
\.((<qcQ<O< l
i
C l (( I Ie:
j i
\.JlJ~ !
j
~ ~ ~ p !
'-" '-" '-"wi.<2> !
~-~t
- I
<2 ~ (!U) -~
<2> I, (CRN) !
I (RID)!
j
r----- ---.--.--.,j.
I FPC Installed
: Equipment &
: Connections
: ""
i ,
: y
! /__u____________
: [ ruses:
i Cou(d ANR-f
: Type CC
: ' SA. 6OfN,
! \. I.C.=200KA I
: , G.,..1,., (ORe) -;
, "-~ ~ (!l.U) !
, : ~....-.u - ~
~- - ;. :::=:: - (WHT /IU("""
, : ' i
! \'........-------------------------1-----------
i
: Connections Internal To
FPC Installed EquJpment.._____L________ ~ Existing Control Cubicle' ~
Standby Generation Proiect rZWW1 0114 ""
~c, 011
5l'HI:
4 Of 5
DOla !~.
1-1 ?_~~ 1.0
IlrII'n ... ,~.--
GEMc WKP ~
w~~v;~~
-z..,..-!z.,.1..--Q)
Generator Interface Module
(GIM)
Req'd Runs
Req. Run
Hours
Actuol Run
Hours
T51
TS2
O.-N
.-NI"1"tl()\o"(])O).-.-.-
~ g ~ ~ ~ l ~ ~ :~I Ig g g g ~: : 1 fl: : ~ : tl
~
8~
~r
......
:.0:::
-J
a3
p..- ~
~~ :J:
~a"-~
e.,~~~
g-
~......
;c3~
~eo
<2>
<2>
<2>
2IP
~.~~
'(5 ~ .9-
I I
'-'-('.1
!a~1
L ~
I
.- ... \I) I")
I I I I
nn
.- .-
!a !a
I I
<2>
(NHT /1lJ(~
^
~
V
01\4- T5 1-1 (ORGr--:-
GI\4- TS 1- 2{ ORG I NHT)
GN-TS1-5(PUR) -
'"' Gf\4- TS1-4{BRN} -
~
Remote~ :.::
Alarm 3 :. =:
-
Module 4 ~-
-
(RAM) 5 ::- ~
6~
\...
~
~
o
~
--
u
a
~
<<1
:<
>
N
~
^
~
V
Wiring Key
<1> = FPC 7 Cond
Load v'gmt Coble
118, 3lXJV, 105' C
Use 3/4" EMT Conduit
As Nee4ed.
<2> == 1/12 Cu TIiN, 6O(N
Use 1" EVT Conduit
As Needed.
Gi\C-TS1-9 (ORG/M1lJ
GlU-TSl-6 (ORC)
Co.'U-TS1-12 (REO/!U)
Gi"-TS1-10 (BlU)
GlU-TS1-11 (REO/WHT/!l.X)-
I ·
P
:J:
~~
00
~X'
I I
~~
I I
~::5
?~iI
---...
(ORO)
(BlU)
('l\'HT /!l.X)
---------
<2>
<2>
<2>
,. Clearwater
DIstributIon
Engineering
.Florida
~ Power
Ct:JlJ'[.RA l1Dol
...J\...
PT
r--~. _~ Cabinet
I l':'A0'b< (PTC)
. '------.,
.. ~iBw) _ ! Xl t !~{___,
I : X1 X2 H1 H2 :
" ~~
2> "~-!!
_ (ORe) _ p...~-+--L__ c
I I I Xl X2 ;
-----~
rq iq iq ~c
~c :B 8l) 5( '- (Am) _ __
-
-::-
<2>
(OOG)
(Il.U) -
(1tHT /!l.X) ---
,/
Neutral MJ
I I
I I
I !
I I
I I
/1---1---------
~H- -..
; I
I I
I !.&]
~~
I
I
I
.
AUI~"~
City of Zephyrhills
Waste Water Treatment Plant
Zephyrhllls, FL
Generator
Output
../"".....
"
C0
00
I
.
-----------.....
. .~ .\.
~ I-
-cd
lC2
-~~l
-",. u J
)(2
I
...
T
.
I
I /
_h________ V
,
Work Instructions
1. Install 18-1 Radio Control Module, Generator
Interface Module, Meter Can, UPS, PT Cabinet
at locations indicated on sheet 3.
2. Install CT's and PT F'uses in the cubicle
indicated on sheet 3.
3. Install cables and make terminations shown on
sheet 4.
4. Install signs.
"'"
Florida Power Corp. SURPlied Materials
1. Transformer rated meter can for 3-element
meter.
2. 3- Element Transformer Rated meter with
registers set for CT=200:5 PT=2?6:120 and
display Multiplier=92.
3. 100' Meter multi-conductor coble,
#12 Cu, 7 cond., with outer cover, 600V THW,
4. 13-1 Radio Control Module
5. Generator Interface Module.
6. UPS
7. PT Cabinet wi PTs (276:120)
8, CT's (200:5)
9. PT Tap Fuses and Holders
10. Remote Alarm Module
11. Outside Radio Switch Antenna
12. Coaxial Cable for Antenna
13. 1000' 7 conductor #18 Control Cable
Note: It is the Contractor's responsibility to coordinate
the installation of the CT's and PT taps with the site
operations slaff.
\...
CQntractor SURplted Materials
1. All Conduit and Wire Termination supplies.
2. All other supplies required for installation.
3. Enclosure for UPS.
4. Signs for FPC Contact and FPC Equipment
location.
, Clearwater
Distribution
Engineering
_Florida
Power
~ \, CDRPlWITUl'4
~
ZWW 1 01 1 5 """
"c.ia 11
~5 OF 5
~12-95 .1) 1
~-.-
~~ m_oJ
\0 &~ ~kJ;~~
1,.. - L.-1- -~ C)
Standby Generation Proiect
City of Zephyrhills
Waste Water Treatment Plant
Zephyrhllls, FL
- ,_._- ---.,..-
FPC Transformer
500 KVA 480V
\..J.....)....}-J
('r(Y'l
) 1000A C.B.
----- ._--
-p--~----
\
\
LOAD
--~-
Emergency
600 K'V
@
Generator
480V
:)
i
900A C.B.
, ,.-" -...
---... ~-
FPC Installed Equipment
I Standby Generation Project
, / ~ene~a~o~ - - - - ~~l- '\
t Interface Meter
"
~-- - - - :Module
___ _ _ - - I - 276/~
/ I ~ 3
, ~~
\ 200/5 ~ ''''." 5A 600V IC=200 KA
"
.
Automatic
Transfer
Switch
Clearwater
Distribution
Engineering
.FIOrlda
, Power
~,~
",
j
/
"
Standb
City of Zephyrhills
Waste Water Treatment Plant
Zephyrhflls
ZWW 1 01 1 2
1
2 OF 5
~.
01
n. ~
W~ .~- ~
1--V1-~
fPC
500 KY A
TAANSf~
Stotfon #
11049....:>0-0512860
~
WAlH CONTROL
ROOt.I
eoo ~"W
~LRATOlt
q:
Exrsti~g Meter
12~616n
:",toll:
is-l ,~Gdfo ltodule
Ger..robr in!6noee
Io/~'JI.
KWH ~atar
Exi.rool Antenno
A
i-
I
I
I ~
I
: --
I ,..
I .
I
I
I
I';
I~
L._...
--- inatoll C.T,',
ond PT F'..S61
___ PT
CtJblnat
1--- UPS
A
Equipment Location Sketch
Note:
Remote Alarm Module to be
in the Office Building and wired to
Radio Module thru existing underground
conduit system.
Clearwater
Di stnbut;on
Engineering
.Florida
Power
~TlIl'C
_~ ,~A~~~
Section AA
KN>~ Veter (KN~)
Ce~erctor nter'oce
$- 1 (!
~?;;~eC(~:~ ' YOM G V) 1 I ~
~ ! r-,-j;~~~~rr-T- e -,----- ~rk
II v 'Il! , ! .
~~~T~~
," PiC I ~J ~- PIC I i
I: I I ." ..
, /':L EVTII, I ~ ' EF
13/4" EVT
I
I
:~O~~C = ~L
C:rCL..'t , LPS ·
PT
Cob:"et
(P'-C)
,
. ,
i i
, I
I I
~
rl@-=-'-~ :
: 0 --".,-
. ,..-,
: I ,-- L-'J.
I L..A LW'
Ren"ote AcrOT! l/oooJ e
(RN))
.- E\.(T
i
-0 C"s 0"'0
~T COl""oc:'o"s
Egillpment Installation Detail
Standb
City of Zephyrhills
Waste Water Treatment Plant
Zephyrhills, FL
r
System PONer Source
, UPS
I
I
Neutral
~ 120 VAC
~
<120 V1C N> 1 ::;:;;
~N> 2 ~......
~--
<\4JH> 3 ~ ~
<.iU-~ 4 ~ ~
<\{R-2> 5 ~:;;
<\{R-3> 6 --.......
~.....
IS- 1 7 0:0
R d. 8 0:0
a 10 9 0:0
Control1o 0:0
Module 11 0:0
t (IS 1 ) 12.Q;Q
.l-
-
~
Renloted = =
AI -~
arm 3 ~~
.....
Module4 ~ ~
- -
(RAM) 5 :: ~
6 Q:2.
~
~
~~
00
..............
Generator Interface Module
(GIM)
Req'd Runs
Req. Run
Hours
0:: a:::
~~~~
~ Or-N
r-NI"')-T>l)U)"lX)(7)r-r-r-
I I -
~~ ~ ~ ~ Jijg >:
LJ
<1> J--=
~
--5-
~5
71
<2>
<2>
TS1
r- r"
Vlv)
II
22
a:::=>S
lllo..!i:'
~~2
I I
r"'-N
~~l
I ~
I
^
~
V
Gl\f- TS 1-1 (ORG)--=-
GlI.f- TS 1- 2{ ORG/NHT}
GN-TS1-5(PUR) -
Gll.f-TS1-4(BRN} -
TS2
Actual Run
Hours
O.-N
.-N""~I()U)"Q)O).-.-.-
H (fl g ij ij ij: : c g ~
-
:s::
~
p- ;:::.
:I:~ :I:
~'d-~
O~~~
......."-"'......,........
r-"'IOI")
I I I I
~~~~
I I I I
~
.....
::1
o
~
.....
U
e
~
111
:(
>
N
~
^
~
V
Gil.f-TS1-9 (ORG/ftHT)
GiU-TS1-6 (ORG)
Q\f- TS f -12 (RfD /BU<)
Q\f-TS1-fO (81U)
GlY-TS1-1f (~/~/~)--
~
s-
:t:3~
~eo
<2>
<2>
<2>
<2> IFI A
(M/~"
<2>
..... - (BW)
FPC Installed Equipment ...------ -r-------------... ~
I . : Connections Internal To
~ 3-Element I Existing Control Cubicle
~~ i3-Terminal!
g.~ KWH Meter :
, I
~ ~ (MTR) !
~ ~ rr= =.... ('~ r<') .... 0 NOr<) 0 0 I
aQ _ II 0..0.0..0000000.. j /"
T i Neutral}.of]
- qcqCOCCCCC : i ·
I I I
)( Oc C (~~ :; I
~ ~ ! I
lJ\.Jg I II I
0'2'- p j I
~ a::: ~ ~: i
....... e '-" ~<2>' I J
LJP t--l,-----l------.------
-:: i / I
i !
<2 L ". I
,- (BU<) -; -... I .. <-
j I J
<2> , (GRN) -T- 1 H
! I !
! -.Q
(RED) : _ ~
I ~.
,-------.----..; · IlC 0
i FPC Installed I-Qry
: Equipment & I i
: Connections I
1 "";! I
: /-----r~:------~ i
: Cou~ AM-1 I
!, ~~ I
: . \ · I.C.::200KA i
~ + :: ~ _(ORC)__i
~ : ::: 5-- (!l.U) I
i . == ('MfT/lU'i
! ',..- ---------------..--------1----------
j
: Connections Internal To
FPe Installed EquJpmen4____.__L________~ ExlsUng Control Cubicle' ~
Standby Generation Project ""ffI!ii10114"
...-c; 011
~ 4 Of 5
--
OIUI 1_.
1-12-95 1.0
arn., ~ ~
GEMc WKP ~
W~~~~~
'1,... "v-z".-q ~
~-~
Generator
Output
/'-,
sO'
il
(ORG)
-- (BlU)
(tOO /1lJ<)
<2>
-i-L.
~..:
[Co
.a'-t
Wiring Key
<1> := fPC 7 Cond
Lood V9mt Coble
118, 3JXJV, 105' C
Use 3/4- EMT Conduit
As Neooed.
<2> = 1112 Cu mH. 6O(N
Use 1. fJIT Conduit
As Needed.
PT
H1 H2 .
.--10. .0-1.... CabInet
I I~M~r (PTC)
"-----,
I X1 X2 Hf H2 :
I I
! r--t?~f
;; ,-----"
! ! X1 X2fgfH1 H2 :
2 I I ..-----
~(ORG) _ ....,+-~ l C 0<
I I I X1 X2 :
______--.J
i~ i~ i~ ~~
~c ~( 8e 5( - f~'HT).. --
-~
<2>
<2>
<2>
(000)
(Il.U)
(MiT /00<)
,
Clearwater
orstrlbutron
Engineering
.Florida
!9P. Power
~1JIJ,j
~""
City of Zephyrhills
Waste Water Treatment Plant
Zephyrh ills, FL
""
C0
i
I
I
I
.
.
I
.
I
.
.
.
--------- --.- - t....,."..
-~.
1
I
.
.
I
I i
_h_____.._. V
Work Instructions
1. Install 18-1 Radio Control Module, Generator
Interface Module, Meter Can, UPS, prr Cabinet
at locations indicated on sheet 3.
2. Install CT's and PT Fuses in the cubicle
indicated on sheet 3.
3. Install cables and make terminations shown on
sheet 4.
4. Install sIgns.
Florida Power Corp. Supplied Materials
1. Transformer rated meter can for 3-element
meter.
2. 3- Element Transformer Raled meter with
registers set for CT=200:5 PT=276:120 and
display Multiplier=92.
3. 100' Meter multi-conductor cable,
# 12 Cu, 7 cond., with outer cover, 600Y THW,
4. 18-1 Radio Control Module
5. Generator Interface Module.
6. UPS
7. PT Cabinet wi PTs (276:120)
8. CT's (200:5)
9. prr Tap {t'uses and Holders
10. Remote Alarm Module
11. Outside Radio Switch Antenna
12. Coaxial Cable for Antenna
13. 1000' 7 conductor #18 Control Cable
Note: It is the Contractor's responsibility to coordinate
the installation of the CT's and PT taps with the site
operations slaff.
Contractor Supplted Materials
1. All Conduit and Wire Termination supplies.
2. All other supplies required for installation,
3. Enclosure for UPS.
4. Signs for FPC Contact and FPC Equipment
location.
City of Zephyrhflls
Waste Water Treatment Plant
Zephyrhllls, FL
Clearwater
Distribution
Engfneering
_Florida
Power
~T1D'.
Slandb Generation
o
-
.
.
o
'>
-
V
1-
~!i
I~
~1
-
13
II~
il
~
"C
'i
~.
e~
8:1
O:J
00
Ov I: I:
.!!5 N2
=0
E.e 'S&
e ~ t...
l 0 I:
--
I: 0
. g-
o.. U J:: 0
~:... !t~
~.o ~ .
2~ _S:
~~ g-
,. u,- ~i
~:...o -
.,.os: 'is c
...... "U.... 0
~ 1:1: ~z ~
~ ~JJ 11 i
o.~~~=S! oS
c .2 ELI.. g 01 C e
.2 '22:... >-.c 0 0
-- 8.~.o.o~ ~ ~
~ aU"i ~ 8 ~ ~
CU.::: 00 <.) .
., ~~vg ~ U
C) r'U iJ .!J ~ ~
~:~=~E)
0:_ ~E" Vi
v:Jc~ __
'l:sr.ov~.
~o::'O ~ 5 (f) f= .,:.
v
c
o
01
j! ~.
i -0
~ l~
... .8
e ~a..
a
E !r
N ]-!
'0 ~:z
-.
-e '5~
Ii :E"
8 ~e
!~
~
s::
~o
~i
'I:
j:
~!i
c~
82
~;
os::
0::.
~U
v
.
1
:J
i
0::
L
o
e
.
e
~~
Q:
jg
:~
:Jv
15
~i
'i:.
3.
v~
fT
1:
-.
:J.c
0_
'-II
20
~=j
~:
10
-J!
l!=
~:J
ci
00::
Ec
~:
~o
'-
~
~E
u:J
OC
0...
.1:,'
~~
~'8%
-"I: s::
:J!.:J
~a..o::
-
o
v
s::
w
N
.....C'.l ...-
m...... 0)
.-...... .. "....
.....<0 't; ..-
, , 0 I
C'.l N .... N
roro C ro
.. 1"-1"- 0 I"-
.... 0
(.) ~
.2 ~~ .,
c.....- ....
o roro 0
o~~
., c
= It 0
(/) ....:t:
o ::J
L 0(1)
"2
E .:J.C~
.2 (.) 0
.,---
:J l.l: 0
o
~ e
o ~
L C;
C) (I)
E .!
o :J
.... 0
~ .J
:J
o
..
-
<.)
o
-
C
o
o
...,,,
N....
~fO
.u;1
e-.
1:8 ...J~
o LOILo.. "
i'!~ 1
~i;i~
C t-8m f-
w 'I: '0""
::::00. ..-
o miA:cio e-
o..
I.&.
o~o
Oc"o
I/):J"I:
OgO
a.oG:
----k
,.....
~
..-
co
.......
Q.
o .ld
:2
"
:g
1!
o
::z
"C..!"o
"Os:: .'0..
e--c
o. ~-ao
~~! ~~
~la:~~
-~_'l:~~
-0 C~l&.-
~ ~ -
.! e E e.... 0
x ~i ~i:l ..
~ ~'" ~CI)1J} ~
C I' . . .
-<-4...,-t1l)
E i- -i-
~ ~a ~6i~
o
c
o
~
~
L!/
., ,
--
Oc
~.
.,E
--
f/JO
ot
~1-
>
oc(
e
~
~
-
o
C
o
:;::
o
<.)
o
.J
T'"""
T'"""
T'"""
0"'"
,.a
"0
Q
\'d
~
U)
)~f
o :J :
~~E
j 1! ~
oow
o~
. ~
.-
o
I :J!
w
U
+-
C
o
a..
VJ +-
C-.J
<DlL.
E
+-
o
CD
10..
l-
;=
1:
~
..c:
a.
<D
N
fh
-
-
0-
..c
10.. 10..
lot- CD ~
O+-..c
o 0-
~ CD
N
~
+-
,-
o
CD
+-
VJ
o
~
ot...~
:g ;I~
00
G:a...
CI
j
~
~
i.
Standby GeneratIon OvervIew:
F10rfda Po,"" CorporatIon'. standby Oeneratlon Program I. a Pa..I.,. Sya"'" u.ed to
rt.qu..t that the Cuatomer .tort theIr standby Oenerator and reduoe ttt. amount
of energy aupplled by FPC.
Work wUl be done by a lloen.ed electrical contractor utlUzlng approved wIring devIce.
and In.tolled accordIng to the NEC and the looal Inlpeotlon authority.
System DescrIptIon:
The standby Generatlon tnmllaHon con.tata of 2 matn el.rnentlll
1. A RadIo Controlled Alarm Syatem whtch lndlcat.. the BegInnIng and End of Requ....d
G.n.rator Run Period, and control. the Metering paokag..
2. A .......ng Package whtoh monltora ttt. o.nerator Output during reqYHted Run
Perloda. the number of Run Requeata a. well al the Reque8ted and Actual Generator
Run Houra.
FPC EngIneerIng Contact:
BIll PenhalltCIon
Florlda Power Corp.
P.O. Box telt - CW23
Clearwater. FL 34e17
(813) SU-S713
DrawIng Index:
Sh..t 1 - Ovwvtew. Indu and Looatlon Nap
Sh..t 2 - Sy8ttm One-Une
Sh..t 3 - EquIpment Pla"ment
Sh..t ... - Syattm WIring Detail.
Sheet 5 - Uat of F'PC Supplied Natllrlall -
SpecIal In'tructton'
LocatIon Map:
Customer SIte Contact:
Rtck t.4oore (813) 782- 1 191
Clark Sutton (813) 782-6142
Customer Corporate Contact:
Loute Sella... (813) 782-1191
! ~~
Alston A V
Waite Water
T,..atment Plant
'"
o
Clearwatw
Dt8trlbutton
Engtn..rlng
_FlorIda
Power
~TtEIN
Standb
City of ZephyrhTlls
Waste Water Treatment Plant
Zephyrhllls, FL