Loading...
HomeMy WebLinkAbout95-4881 BUILDING PERMIT ~ 1(- Permit Fee (J?). 04-...J Signatur~ '-} '}.1eAA... W', ~6 vU'^-'-- Company Address Telephone# 06.2..50 CITY OF ZEPHYRHILLS (81l) 788-6611 S :2.-!:,--o PLUMBING BUILDING to-J-S ELECTRICAL :J..,S--' CJ1) MECHANICAL P<op."Y own",o~ 6~ Job Address: Y . ,"?' ~; L Parcell.D. # /s-- tLh ~;LI -...$ - .3 iJ .. /0 Zoningo En"'gy Codeo 0 . RadOna" 1t:;.J. Description of Work ~.L.A-J ~~-&. J4 ~..JA NO OCCUPANCY BEFORE C.O. Complete Plans, Specifications and Fee Must Accompany Application, All work shall be performed in accordance with City Codes and Ordinances. Valuation or ":) J7 Contract Price W ~ / n ()7) Permfit PiP. 4881 (j Date '1-.2 b ~ 9s- Sewer Conn j,:;J...? K". OV Water Conn: 3-.SZJ - O?J Water Meter: /6..5. cJ?) , - ~ 7- /' ..Ll ------ TI.F,s:/e he: c:u L.v. " :;0 ;J ':'1 /f + ~ ~ FINAL Inspector City License Registration # .2 '73 State Certified License# Const. Pole Pool Pre-Meter Io-;J- 9s./308 Final Driveway ~ ~-2--q~~ ~~hen ex"a inspection "ips are necessa", due to anyone of the following reasons. a charge of Fifteen and 00/100 Dollars ($15.00) shall be made for each trip for each trade: a. Wrong Address 7J-ut; ~J- ~j y -c26 -XJ- b. Condemned work resulting from faulty construction. A c. Repairs or corrections not made when inspection called. d..( tJ -- 61 () -7 ~ d. Work not ready for inspection when called. / e. Permit not posted on job site. f. Plans not at job site. g. Work not accessible. r-p. AA;)N'n ~(j~ ELECTRICAL / 6 ~ ~;;;.Jl.nv>, PLUMBING jt) /' SLB 1-~ iju.- Tub Set r']-\Q43 BILL Water ~/ft;r[f5&1r Sewer . BUILDING Ftr. 52-'i5tut- Pre SL /' <- Lintel ~ -S-:-q&f J3~ FRM. 1-1<1-9'$ EILL Insul. CL WL 7..- 2-0 -qs,SoB Tp. Serv. Rough In '1-\Q-QS .BoR Meter Can '9..:26 -1-..5 Final '1Yt~ MECHANICAL )7)~ Breakers Ducts Insl. '1- J 9-9$ e~ Compressor Final The payment of inspection fees shall be made before any further permits will be issued to the person owning same. Russell Brown 4753 Silver Circle VALUATION: $39,788.00 SQ. FT. LIVING: 1,029 COST/FT: $35.00 SQ. FT. OTHER: 343 COST/FT: $11 .00 VALUATION $39,788.00 DRIVEWAY $20.00 ADDRESS $20.00 FEE SHEET $215.00 SQ. FT. UNDER ROOF 1,372 RADON GAS $13.72 TRAFFIC IMPACT FEES 99% 1 % $1,480.00 $1,465.20 $14.80 PERMIT FEES BUILDING: PLUMBING: ELECTRICAL: MECHANICAL: SUB-TOTAL: CREDIT: TOTAL: CONNECTION FEES SEWER: WATER: METER: TOTAL: 362.50 52.50 60.25 25.00 $500.25 36.00 $464.25 1,278.00 350.00 165.00 $1,793.00 GRAND TOTAL: $3,750.97 C ~\iL-FoNT VILL~S PL~rl1[ 800\-'\ 3\ PH(:CL:,O 1+ I 53. S \ LV ERe IRe L t: ) L 0\ \ 0 J ~r I I I , /r I ilLf-- . 0 L.. 1 I ,. 7,5 1/ {, 2Cf.o I : 2.0,33, I I '1' I N o1(rH- '"2 13,60 (.? 00 1M.. \-to vSE ) ":< G c:, JZf- , 7lf- D 4-3, b) I I I % I I I I ; 10'0'1 I i i -.----------------.- -- ---.---..-.--- '-'--,- .'_. ---___._.._.__~h.__.__.,___.__ ---'.. ..- -. .~---. ---_,_ -1--- __ ~_'_~ -'--' ------_.,._~_.._-~,.._-_._--_._._-. / APPLICAnON FOR PERMIT CITY OF ZEPHYRBILLS BUILDING DEPARTMENT OWNER'S NAME Q U$~6 LL. yV\. ~QOlUI'-~ PBONE 7 '80 /l>L.Y... OWIiER'SADDRESS i)7.3b JLl/"Lc:ELH LOURT Z'\j)LCS r-C.3.:?s4--\ JOB ADDRESS 4'( <5 3, S I J.....v E f( C IRe L(: '2 E PH 'y1<JO LL s:. F L ~ rs S-4 I LEGAL DESCRIP'lION: LOT(S) BLOCK SUBDIVISION C (-/.I4L Fa !--.it V ILl 145 PARCEL I.D..12..ELOr? D PLy\-T Boot'\. 'S \ PY\&E'7{) (OBTAIN PROM PROPERTY TAX NOTICE) WORK PROPOSED: t./Hew Construction ---..Addition ---..Alteration --.Jlepair _Install _Sign --.Hove _Deaolish PROPOSED USE: \/'Single Fsaily --.H/F _' of Units _M/H _ec-ercial _Indust. _Swia. Pool _Other ---Restaurant & Health Departaent Approval DESCRIPTIOR OF WORK: BUILDIRG SIZE: 2 q X '4-s{.,") J 2(t, Square Feet, I '8 Height RESIDEIITIAL: AnACH (2) PLOT PLANS air (2) SETS OF BUILDING PLANS air (1) SET ENERGY FORMS. COHMERCIAL: ATTACH (3) SETS OF BUILDING PLANS air (1) SET ENERGY FORMS. PROPERTY SURVEY REQUIRED FOR ALL NEW CONSTRUCTION. PERMITS REOUESTED .L.BUILDDlG V RI.RCTRICAL V HEawJICAL ;' . - ~ ....1L..nUtlBDlG Valuation of Total Construction AIIP Service l / Florida Power Corp. W.R.E.C. $ Valuation of Mechanical Installation GAS ROOFING SPECIALTY TYPE 9F CORSTRUC'I'lON: -1.L.Bloclt _Fraae _Steel Other FIllISBED FLOOR ELEVAnORS: PT. IS PROJECT IN FLOOD ZONE AREA? ~ YES NO .......................................... BIJH.Dm CONTRACTOR SECTION Cf2 COMPANY q () .5 oS E- LC rV\, ~ )(Cl\...1 \'-\ State Cert. or Regist. . C (T (' n ~ I h I \ .. t~~LL rYl. cg~ City License Registration . cz.. 4--'5, ........................................*. Signature HECIIAlf[CAL Cf~L0k1A COMPANY 'i!. US~(:::-LC 1"1/\. <J2,12olu/~( 1"\A (j) State Cert. or Regist. . en. (:x::> 105.c; I ~:::> 'Vt"l,~ ' City License Registration . 1 b X .......................................... COMPANY 9 uss.F. Lc t\t. ~J2.oCv/--( (-;) State Cert. or Regist. . r.: reo ~?,C{qq c M. ~W1...~ City License Registration' (0'/ ..................................******** COMPANYQC) $S,.(-::-I_L 111. ~ftOw/d r:;-) State Cert. or Regist. # c..1'\ La 4-1 '2.~4- tv\. J"')~~ City License Registration, ~ll ...........*.***..*...**........*..*.***** ELECTRICIAH SiQIIAture q~lL PLUMBER qt~lt Signature Signature OTRRR COMPANY State Cert. or Regist. . Signature City License Registration I .......*...*..**.**.*.*.*.**.*.*******.*.. APPLICAnOR APPIIOVIlD BY '11d'~cr l'f/ ff',~J PEIlKIr OPPICER. CONDITIONS OF PERMIT AFFIDAVIT A. NOTICE OF DEED RESTRICTIONS The undersigned understands tbat this pertit .ay be subject to "deed restrictions" whicb lay be lOre restrictive than City regulations. Tbe undersigned assUles responsibility for co.pliance with any applicable deed restrictions. B. UNLICENSED CONTRACTORS AND CONTRACTOR RESPONSIBILITIES If the owner bas hired a contractor or contractors to undertake work, they .ay be required to be licensed in accordance with state and local regulations. If the contractor is not licensed as required by law, both the owner and contractor .ay be cited for a .isdeaeanor violation under state law. If the owner or intended contractor are uncertain as to what licensing requirements lay apply for the intended work, they are advised to contact the City of Zepbyrhills Building Departlent, (813) 788-6611. Furthermore, if the owner bas bired a contractor or contractors, he is advised to bave tbe contractor(s) sign portions of the "Contractor SectionsU of this application for wbich they will be responsible. If you, as the owner sign as the contractor, you are indicating that you, ratber than the contractor, are responsible for the work. If the contractor wishes you to sign as contractor that .ay be an indication that be is not properly licensed and is not entitled to per.itting privileges in the City of Zepbyrhills. C. TRANSPORTATION IMPACT FEES AND UTILITY CONNECTION FEES D. CONSTRUCTION LIEN LAW (CHAPTER 713, FLORIDA STATUTES, AS AMENDED) I certify that I, the applicant, have been provided with a copy of uFlorida's Construction Lien Law - HOIeowner's Protection Guide" prepared by the Florida Departlent of Agriculture and ConsUler Affairs. If the applicant is so.eone otber tban the "owner", I certify that I have obtained a copy of the above described docUlent and pro.ise in good faith to deliver it to the "owner" prior to couencelent. E. CONTRACTOR'SjOWNER'S AFFIDAVIT I certify that all tbe information in tbis application is accurate and that all work will be done in compliance with all applicable laws regulating construction, zoning, and land develop.ent. Application is herehy .ade to obtain a per.it to do work and installation as indicated. I certify that no work or installation has COIIenced prior to issuance of a pertit and that all work will be perforted to .eet standards of all laws regulating construction, City codes, zoning regulations, and land develop.ent regulations in the jurisdiction. I also certify that I understand that the regulations of other governlental agenCies lay apply to the intended work, and that it is .y responsibility to identify what actions I lust take to be in co.pliance. Such agencies include but are not lilited to: A Department of EnviroDlental Regulation - Cypress Bayheads, Wetland Areas and EnviroDlentally Sensitive Lands, Water/Wastewater Treatlent A Southwest Florida Water Managelent District - Wells, Cypress Bayheads, Wetland Areas, Altering Watercourses A Army Corps of Engineers - Seawalls, Docks, Navigable Waterways A Departlent of Health & Rehabilitative Services, EnviroDlental Health Unit - Wells, Wastewater TIeatlent, Septic Tanks A US EnvirODlental Protection Agency - Asbestos abatelent I also certify that, if fill .aterial is to be used in Flood Zone "A" or "A, etc. ", it is understood that a drainage plan addressing a uCOlpensating volUle" will be subtitted which is prepared by a professional engineer registered in the State of Florida prior to per.it issuance. A p~r.it issued sball be construed to be a license to proceed with the work and not as authority to violate, cancel alter, or set aside any provisions of the technical codes, nor shall issuance of a per.it prevent the Building Official frCl thereafter requiring a correction of errors in plans, construction, or violations of any code. Bvery peIlit issued sball becole invalid unless the work authorized by such permit is cOllenced within six IOnths of issuance, or if work authorized by the per.it is suspended or abandoned for a period of six IOntbs after the tile the work is cOllenced. One 90 day extension of tile, laY be allowed for the pertit with fee charge of $15.00. The extension shall be requested in writing to the Building Official. An approved inspection lust be logged during each six IOnth period, or the project will b~ considered abandoned. WARlHNG TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMBNCRMEN'f MAY RESULT IN YOUR PAYING TWICE FOR IHPROVRMEHTS TO YOUR PROPERTY. IF YOU IHTBlID TO OBTAIN FlIfAlfCIHG, CONSULT WITH YOUR LBNDBR OR AM ATTORHBY BBFORE RECORDING YOUR NOTICE OF COMMBNCEMENT. JOBS UNDBR $2,500 IN VALUE DO NOT NEBD TO RECORD AND POST A "NOTICE OF COMMBNCRMENT". 9.w~ M.cg~ SIGNATURE: CONTRACTOR SIGJlArURl!: OWNER OR AGBlfl who is personally known to me or who has produced as identification and who did/did not take an oath. STATE OF FLORIDA n COUNTY OF YOlSCl.-D The foregoing instrument was acknowledged before me thisQ~, l~ ' 19~ by R~S~(I ~. t3~"j who is personally known to me '9r lille hlut prgQy.eed as iEleBtifif;ation and .who 'Ctttt/did not ta~~J' (?~ (Si9~~ L.BLl~ (Name Typed, Printed or Stamped) NOTARY PUBLIC ......~~;.~..... OFFICIAL SEAL ~ ~ ~ BRENDA L. BUCHANAN ... . : [;1 : My Commission ExpIres \. ~ ! Nov. 13. 1996 ..~reOFfl~"" Comm. No. CC 240110 1r.~...lt't*1t STATE OF FLORIDA COUlflY OF The foregoing instrument was acknowledged before me this , 19____ by (Signature) (Name Typed, Printed or Stamped) NOTARY PUBLIC Department of Community Affairs. FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION FORM 600A-93 Residential Whole Building Performance Method A CENTRAL 4 5 6 PROJECT NAME: C H 'A \- f()\-..IT Y \ LL \4.$ BUILDER: /~:!.) S. S.t:: LC ni. \::. R mu 1'-( AND ADDRESS: z::.. c P H '/ R H I LL$ PERMITTING CLIMATE 40'5060 pI 335q.1 l/f)..s3 II /'- ,I OFFICE: Z. ,'; PH \('R H I LL~ ZONE: OWNER: 'Russ c5L L- yv1. 'BRo!..Ll"-( PERMITNO.~ JURISDICTION NO.: ~ 1. New construction or addition 2. Single family detached or Multifamily attached 3. If Multifamily-No. of units covered by this submission 4. If Multifamily, is this a worst case (yes / no) 5. Conditioned floor area (sq. ft.) 6. Predominant eave overhang (ft.) 7. Porch overhang length (ft.) 8. Glass type and area: ' a. Clear glass b. Tint, film or solar screen 9. Floor type and insulation: a. Slab on grade (R-value + perimeter) b. Wood, raised (R-value + sq. ft.) c. Concrete, raised (R-value) 10. Net Wall type, area and insulation: a. Exterior: 1. Concrete block (Insulation R-value) 2. Wood frame (Insulation R-value) 3. Steel frame (Insulation R-value) 4. Log (Insulation R-value) b. Adjacent: 1. Concrete block (Insulation R-value) 2. Wood frame (Insulation R-value) 3. Steel frame (Insulation R-value) 4. Log (Insulation R-value) 11. Ceiling type, area and insulation: a. Under attic (Insulation R-value) b. Single assembly (Insulation R-value) 12. Air distribution system: a. Ducts (Insulation + Location) b. Air Handler( Insulation + Location) 13. Cooling system: (Types: central-split, central-single pkg.. room unit, PTAC., none) 14. Heating system: (Types: heat pump, elec. strip, nat. gas, L.P. gas, room or PTAC, none) 15. Hot Water system: (Types: elec., natural gas, solar, L.P. gas, none) 16. Hot Water Credits: a. Heat Recovery (HR) b. Dedicated Heat Pump(DHP) 17. Infiltration practice: 1, 2 or 3 18. HV AC Credits (Type in Letter designation: CF-Ceiling Fan, CV-Cross vent, HF-Whole house fan, AS-Attic radiant barrier, MZ-Multizone) 19. EPI (must not exceed 100 points) a. Total As-Built points b. Total Base points E PI = Total As-Built points X 100 T olal Basa points Please Type CK 1. NElU C-oI'-l. 2. SF'D 3. NI~ 4. N\A 5. ile.3 sq. ft. 6. \.0 ft. 7. G'O ft. Single Pane Double Pane 8a. -1S'\ sq. ft. sq. ft. -- 8b. sq. ft. sq. ft. 9a. R= '2. , l4-q I. ft. 9b. R= , sq. ft. 9c. R= , sq. ft. 10a-1 R= 7.(;, GLf-o sq. ft. 10a-2 R= sq. ft. 1 Oa-3 R= sq. ft. -- 10a-4 R= sq. ft. 1 Ob-1 R= sq. ft. 10b-2 R= 1\ (ICl) /, ~\ 'Z(.,(), '30) sq. ft. 10b-3 R= sq. ft. 10b-4 R= sq. ft. 11a. R= 1(:\ C\ '2. 1? sq. ft. 11b. R= sq. ft.- 12a. R= G'S , U /-0-' to ,'I') (condJuncond.) 12b. R= b'S , UI,J,r6~lD (condJuncond,) 13a. Type: C / .s 13b. SEERlEERlCOP: I~ 13c. Capacity: '2 '<, 'M'K\... 14a. Type: HI'? 14b. HSPF/COP/AFUE: {-00/3:00/- 14c. Capacity: 21- G \'Y\'B \~ 15a. Type: EL \::c. 15b. EF: .gq 16a. :L,,--/ j ;_~ 16b. rJ /H - 17. ~~ - 18. C.F 119. - I ~I . ~~~... 19a. 15 C/o5 - 19b. 1'1.511- - I hareby certify that the plans and specifications coverad by the calculation are in complianca with tha Florida Energy C~ PREPARED BY: 'rf..tuI)r).J_ M. t}3~ DATE: 4 - n. q 5 I hareby certify that t~ing is in compliance w"h the Florida Enargy Code. '~'J m (\) }, 17 ar- OWNER AGENT: H.:.A-A, .DV1Y,-^,^,", DATE: ' i' .. ,':;' ~. i "I,. Review of plans and specifications covered bV this calculation indicates compliance with the Florida Energy Code. Before construction is cOlJlpleted, this building will be inspected for compliance in acco~t~ 553,908, F,S. _ BUILDING ~AL' s=:: ~ ~l-' .A 0", DATE: - .:::L ....::..5 SUMMER CALCULATIONS CLIMATE ZONES 4 5 6 GLASS T BASE I BASE GLASS ! SINGLE-PANE ,1- DOUBLE-PANE T SUMMER lAS-BUilT AREA x SUMMER = SUMMER SUMMER POINT MUL T. OR SUMMER POINT MULT. x OVERHANG = GLASS POINTS AREA CLEAR TINf'! CLEAR TINf2 FACTOR (6A-l) SUM. PTS PT. MUL T. N 2.' 82.2 ~\~l N "'2-(., 51.0 51.5 47.8 43.5 .GCl CU~ NE 82,2 NE n.2 76.6 71.7 63,4 E \4- 82.2 \ \ 5 \ E \4- 109,2 107.1 102.0 87.3 #'8~ I'2.ClC\ SE 82.2 SE 112.9 110.3 104,1 89.4 S 4\ 82,2 ~"2.7 0 S 4-1 100.2 98.3 90.9 78,8 \ 4-io1[ SW 82.2 SW 112,9 110.3 104.1 89.4 W 82.2 W 109.2 107,1 102,0 87,:3 NW 82,2 NW n.2 76.6 71.7 63.4 H' 82.2 H' 367.7 303.3 324,6 238.1 ~ :5 Cl . T 'II' l' .15 .15 x COMPONENT J BASE SUMMER I BASE AREA SUMMER DESCRIPTION x POINT. MUL T. = POINTS EXTERIOR t:.4-0 1.0 Le>t-i 0 ..... ADJACENT '<, C( D .7 ~L '1 '"2, ..... ~ l' en EXTERIOR 20 4.8 , ..'j\,;;) a: 1"3 ?<q 0 ADJACENT 1.6 0 0 I: ,^-.r .~:() L ~ "I(': ~ -11- ~.~=' ~~.(~ l' .:.- ~( l' q~ " ." L-," i) l' Cl UNDER ATTIC tl'''2..'7\ .6 C;S } UNOCR F\"lTIC cf 'L <s \ ' \ 10"/ \ z OR SINGLE ,6 ::i jjj ASSEMBLY (.) BASE CEILING AREA EQUALS FlOOR AREA DIRECTLY UNDER CEILING. AS.BUIL T CEILING AREA EQUALS ACTUAL CEILING SQUARE FOOTAGE. l' SLAB (PERIMETER I u.. tt -31.8 -4-,3'X <::"LHE. 0,,"1 l)..l,i-J::.:( \4-"\ -3\ ,cl -LI-I ~ '( a: RAISED /AREAl -3,43 0 0 Ii FOR SLAB ON GRADE USE PERIMETER LENGTH AROUND CONDITIONED FlOOR. FOR RAISED FlOORS USE AREA OVER UNCONDITIONED SPACE. INFilTRATION \O,q 10.9 TOTAL COMPONENT BASE SUMMER POINT~ COOLING BASE COOLING TOTAL BASE SYSTEM SUMMER SYSTEM MULTIPLIER POINTS .37 \ 'Z '2.'1 "8 BASE COOLING POINTS 07/0 HOT WATER SYSTEM NUMBER OF BEDROOMS '2- NUMBER OF x BEDROOMS '2.. BASE x HOT WATER MULTIPLIER 3527 BASE = HOT WATER POINTS 1054- AS-BUILT HOT WATER SYSTEM DESC. l' ,. 100t..o 1 l' \'< 'i'iC1 '"L ---' AS-BUILT COOLING POINTS 4'~b<;J AS-BUILT = HOT WATER POINTS ~l 05 (:{ 'H = HORIZONTAL GLASS (SKYLIGHTS) 2FOR GLASS WITH KNOWN SHADING COEFFICIENT, SEE SECTION 1.1 OF APPENDIX C. TINT MUL TIPLlERS MAYBE USED FOR GLASS WITH SOLAR SCREENS. FILM, OR TINT. .2. SOMMER POINT MULTIPLIERS (SPM) CLIMATE ZONES 4 5 6 6A.1 SUMMER OVERHANG FACTORS ISOI =l FOR SINGLE AND DOUBLE PANE GLASS. ~r OH RATIO .00-.11 .12-.17 .18-.26 .27-.35 .36-.46 .47-.57 .58-.70 .71-.83 .84-U8 1.19-1.72 1.73-2.73 2.74+ N 1.00 .94 .91 .87 .83 .79 .75 .72 r.69 ) .62 .56 .50 NElNW 1.00 .94 .91 .8i .79 .72 .68 .63 :5'"8 .50 .40 .36 t;a: EN! 1.00 .95 .92 (8s) .78 ,70 .64 .58 .52 .42 .33 .26 wO ~l SElSW 1. 0 .93 .90 .81 .72 .62 .55 .49 .42 .33 .27 .22 S (1. 0) .91 .87 .77 .67 .57 .50 .45 .39 .32 .28 .25 -nUll:tJ~T\.I' if 1 ft 11,i, ft 2ft ~ft ~1j,ft d.i!:it I\1/,ft E;1j,fI ' Ql/"it 1d.ft ?nft 'To select bv Ovemano Lenoth no ""rt of nlass shall be more than 8 It. below the overhano, STEEL EXT ADJ 8.9 2,9 4.1 1.3 3,0 1.0 2,8 0,9 2.4 0.8 1.3 0.4 CONCRETE BLOCK1 INT. INSULATION NORMAL WT. EXT ADJ .9 .7 .6 .4 .3 .2 .1 6A-3 DOOR SUMMER POINT MULTIPLIERS SPM) DOOR TYPE EXTERIOR ADJACENT WOOD 7.2 2.4 6A-4 CEILING SUMMER POINT MULTIPLIERS ISPMI UNDER ArnC SINGLE ASSEMBLY CONCRETE DECK ROOF R-VALUE SPM R-VALUE SPM CEILING TYPE 19-21.9 ('1.1 ) 10-10.9 3,0 R-VALUE DROPPED EXPOSED 22-25.9 '-:!r 11-12.9 2.7 10-13,9 3,0 3,3 26-29.9 .7 13-18,9 2.4 14-20.9 2.0 2,1 30-37.9 .6 19-25.9 1.8 21 & Un 1.4 1.3 38 & Un .4 26-29.9 1.1 ~n~ OJl INSULATED RAISED WOO()2 POST OR PIER STEM WALL wI UNDER CONSTRUCTION FLOOR INSULATION SPM SPM 0.9 ..5.8 -1.1 ..2.8 -1.0 ..2.2 ADJ~CENT SPM 5.3 2.1 1.8 6A-7 DUCT MULTIPLIERS IOMI RETURN DUCTS RETURN DUCTS R-VALUE IN UNCONDITIONED SPACE IN CONDITIONED SPACE SUPPLY DUCTS IN 4.2-5,9 1.14 1.10 UNCONDITIONED SPACE 6,0-6,6 (' 1.10 ) 1.07 6.7 & Uo 1.09 1.06 SUPPLY DUCTS IN 4.2-5.9 1.10 1,00 CONDITIONED SPACE3 6,0-6.6 1.07 1.00 p.nlln 10E; 1-00 6A-8 COOLING SYSTEM MULTIPLIERS ICSMI SYSTEM TYPE COOLING SYSTEM MULTIPLIERS Ie MI Central Units (SEER) Ratinn 7.5-7.9 8.0-8.4 8.5-8.8 8.9-9,4 9,5-9.9 10.0-10.4 III 0.5-10.9 11.0-11.4 11.5-11.9 12.0-12.4 CSM .45 .43 .40 .38 ,36 ( ,34 ./ .32 .31 .30 .28 PTAC & Room Units (EER) Ratina 12.5-12.9 13,0-13.4 13.5-13,9 14.0-14.4 14.5-14,9 15.0-15.4 "l5:5~15.9 16.0-16.4 16.5-16,9 17.0-17.4 17.5 & Uo CSM .27 .26 .25 .24 .24 .23 .22 .21 ,21 .20 ,19 MINIMUMS: CENTRAL UNITS-AIR COOlED SPLIT SYSTEM 10,0 SEER, SINGLE PKG. 9.7 SEER, GROUNO WATER HEAT PUMP 11.0 EER. PTA(}-SEETABLE 6-2 6A-6 INFILTRATION SUMMER POINT MULTIPLIERS (SPM) INFILTRATION PRACTICE SPM SEE TABLE 6A.21 PRACTICE #1 PRACTICE #2 6A.9 HOT WATER MULTIPLIERS IHWMI SYSTEM TYPE HOT WATERMUbIIPLI~1!iWM Electric Resistance EF .80-.81 ,82-,83 ,84-.85 ,86-.87 / .88.,90 I) ,91-.93 .94-,96 .97 & Uo HWM 3879 3785 3695 3609 "- 3521......... 3411 3302 3200 Natural Gas EF .43-.471 .48-.49 ,50-.51 ,52-.53 .54-,55 .56-,57 ,58-.59 .60-.61 .62-.63 .64-,65 .66 & Uo HWM 2974 I 2664 2558 2459 2368 2284 2205 2132 2063 1998 1938 LP Gas HWM 3638 I 3259 3129 3009 2897 2794 2697 2607 2523 2444 2370 1 FOR MULTIPLIERS FOR OTHER TYPES OF CONCRETE BLOCK CONSTRUCTION SEE SECTION 2.1 OF APPENDIX C, 2 MULTIPLIERS FOR OTHER TYPES OF RAISED WOOD ASSEMBLIES SEE SECTION 3.1 OF APPENDIX C. 3 DUCTS IN CONDITIONED SPACE NEED TO BE INSULATED ONLY TO THE R-VALUE NECESSARY TO PREVENT CONDENSATION. -3- WINTER CALCULATIONS rn rn :5 CI N NE E SE S SW W NW H' GLASS AREA x BASE = WINTER POINTS CLIMATE ZONES 4 5 6 GLASS ~ SINGLE-PANE OIR DOUBLE-PANE 1 WINTER I AS-BUILT WINTER POINT MUL T. WINTER POINT MUL T. x OVERHANG = GLASS AREA CLEAR TlNf2 CLEAR TINf2 FACTOR (6A-10) WIN. PTS N '2.G. 9.6 9,6 5,6 6.1 \. \ ~ Z-q5, NE 7,4 7.3 3,5 4.2 E 14 - 2,2 - 2,0 - 5.6 - 3.6 \q - (~ SE -10,3 - 9.7 -13,4 -10.4 S 41 -10,9 -10.2 -14,0 -11.0 \ -L:.~~I SW -10.3 - 9.7 -13,4 -10.4 W - 2,2 - 2.0 - 5,6 - 3.6 NW 7.4 7.3 3,5 4.2 H' -32.1 -28.0 -27.0 -21,5 .15 COMPONENT .[ BASE WINTER I BASE DESCRIPTION AREA x POINT. MUL T. = WINTER POINTS EXTERIOR (-? 4- 0 1.1 /0<4- ..J ADJACENT '3,c1 0 1.8 -7 0 '2- ..J ~ l' l' rn EXTERIOR '2..0 5.1 10"- I I! :,1 .sU!...i"'" (:: D I '2...0 E ~ I IO'L I ~ 4,0 1'2- ,11 4- ':)'2.. g AOJACENT -1\- l' l' l' AS-BUILT GLASS SUBTOTAL - I ::"i< l' COMPONENT .[ WINTER ! AS-BUILT DESCRIPTION AREA x POINT. MUL T. WINTER 6A-11 THRU 6A-15 POINTS C b \'-..\ ~~ U"\ " 4-(;) :~ . S< ~, cJ.: , '/ vr' _ ~1'D".J \..>.JooO ?GO \ ' () +(~ <g )"lSJ3 \,' 00 (:) 130 \ \ 30 UNDER ATTIC q "'2.. '& ,6 .::.5, U'-I () [(( WI1 I C. C-J? ''is I c:l"O CI ~.:I Z OR SINGLE ,6 ::J iii ASSEMBLY ,6 u BASE CEILING AREA EQUALS FLOOR AREA DIRECTLY UNDER CEILING, AS-BUILT CEILING AREA EQUALS ACTUAL CEILING SQUARE FOOTAGE. l' l' SLAB (PERIMETER 14-?f -1.9 - '"2. 'i<, .'- ~L\4~( o k.{ C'. Jf' "'tot I (J... '-I < ) , .-' :~ 0'1 q, a: ...." ..--" 0 RAISED (AREA) - .2 0 ..J I.L. FOR SLAB ON GRADE USE PERIMETER LENGTH AROUND CONDITIONED FLOOR. FOR RAISED flOORS USE AREA OVER UNCONDITIONED SPACE. INFILTRATION 4.1 TOTAL COMPONENT BASE WINTER POINT~ BASE HEATING TOTAL BASE HEATING SYSTEM x WINTER SYSTEM MULTIPLIER POINTS 1.1 511 t ..J ~ ~ BASE HEATING POINTS ;/,'e3 cr2J. l' 3.1~~ a.. , l' TOTAL COMPONENT AS-BUILT WINTER POINTS .... TOTAL AS-BUILT WIN. PTS. c; I.~, I ~I" AS-BUILT HEATING POINTS LJ:) 9 ~ 2FOR GLASS WITH KNOWN SHADING COEFFICIENT, SEE SECTION 1.1 OF APPENDIX C. TINT MULTIPLIERS MAYBE USED FOR GLASS WITH SOLAR SCREENS, FILM, OR TINT. -4. WINTER POINT MULTIPLIERS (WPM) CLIMATE ZONES 4 5 6 6A.10 WINTER OVERHANG FACTORS (WOA J OH RATIO I .00-.11 I .12-.17 I .18-.26 1 .27-.35 .36-.46 I .47-.57 .58-.70 I .71-.83 .84-1.18 11.19-1.72 11.73-2.73 I 2.74+ SINGLE PANE GLASS o' N 1.00 1.03 1.05 1.08 1.10 1.13 1.15 \.1.18.; 1.20 1.24 1.29 1.34 NElNW 1.00 1.07 1.10 1.15 1.20 1.25 1.30 1.35 1.39 1.50 1.59 1.67 E/W 1.00 .71 .57 r-:-f9) -.20 -.65 -1.05 -1.48 -2.03 -3.01 -4.06 -5.04 SElSW 1.00 .93 .90 -:a0 .68 .54 .39 .22 .05 -.33 -.71 -1.01 ba: S (1.00 ) .95 .92 .83 .70 .54 .36 .13 -.13 -.70 -.98 -1.09 m[ DOUBLE PANE GLASS . N 1.00 1.05 1.07 1.11 1.14 1.18 1.21 1.24 1.28 1.34 1.40 1.47 NElNW 1.00 1.11 1.16 1.24 1.32 1.41 1.48 1.56 1.63 1.80 1.94 2.08 E/W 1.00 .88 .82 .66 .50 .31 .15 -.03 -.26 -.66 -1.10 -1.50 SElSW 1.00 .95 .92 .85 .76 .65 .54 .41 .28 -.01 -.30 -.52 S 1.00 .96 .94 .87 .78 .65 .51 .33 .13 -.30 -.51 -.60 OH LENGTH- Oft. 1 ft. 1'h ft. 2ft. 3ft. 3'hft. 4'hft. 5'h ft. 6'h ft. 9'hft. 14 ft. 20ft.+ 'TO SELECT BY OVERHANG LENGTH, NO PART OF GLASS SHALL BE MORE THAN 8 FT. BELOW THE OVERHANG. 6A.11 WALL WINTER POINT MULTIPLIERS PM FRAME CONCRETE BLOCK' INT. INSULATION NORMAL WT. EXT ADJ 6.0 3.1 '3.8 2.3' 1.9 1.5 1.1 .7 .5 6A.12 DOOR WINTER POINT MULTIPLIERS PM) DOOR TYPE EXTERIOR ADJACENT WOOD 7.6 5.9 INSULATED @ 4.0) 6A.13 CEILING WINTER POINT MULTIPLIERS /WPM\ UNDER ATTIC SINGLE ASSEMBLY CONCRETE DECK ROOF R-VALUE WPM R-VALUE WPM CEILING TYPE 19-21.9 / 1.0.J 10-10.9 1.8 R-VALUE DROPPED EXPOSED 22-25.9 .9 11-12.9 1.6 10-13.!~ 1.2 1.3 26-29.9 .7 13-18.9 1.5 14-20.9 .7 .7 30-37.9 .6 19-25.9 1.1 21 &Uo .4 .3 38 & Uo .4 26-29.9 .6 'lOR. Iln .4 6A.14 FLOOR WINTER POINT MULTIPLIERS WPM SLAB-oN-GRADE RAISED EDGE INSULATION CONCRETE WPM 4.0 1.8 1.1 RAISED WOOD2 POST OR PIER STEM WALL wI UNDER CONSTRUCTION FLOOR INSULATION WPM WPM 7.9 1.8 2.1 .7 1.5 .5 ADJACENT WPM 5.3 2.1 1.8 6A-16 DUCT MULTIPLIERS /OM) RETURN DUCTS RETURN DUCTS R.VALUE IN UNCONDITIONED SPACE IN CONDITIONED SPACE SUPPLY DUCTS IN 4.2-5.9 1.14 1.10 UNCONDITIONED SPACE 6.0-6.6 il.101 1.07 6.7 & Uo 1.09 1.06 SUPPLY DUCTS IN 4.2-5.9 1.10 1.00 CONDITIONED SPACE3 6.0-6.6 1.07 1.00 f; 7 R.lln 1 Of; 1 no 6A.17 HEATING SYSTEM MULTIPLIERS /HSM\ SYSTEM TYPE HEATING SYSTEM MULTIPLIERS /HSM) Central Heat HSPF 6.40-6.79 6.80-6.89 6.90-7.39 ) 7.40-7.89 7.90-8.39 8.40-8.a9 8.9-9.39 9.4-9.89 Pump Units HSM .53 .50 .49./ .46 .43 .41 .38 .36 HSPF 9.90-10.39 10.40-10.89 10.90-11.39 11.40-11.89 11.90-12.39 12.40 & uo HSM .34 .33 .31 .30 .29 .28 PTHP COP 2.50-2.69 2.70-2.89 2.90-3.09 3.10-3.29 3.30-3.49 3.50-3.69 3.70-3.89 3.90-4.19 HSM .40 .37 .34 .32 .30 .29 .27 .26 Electric Strio 1.0 Gas & LP Gas 1.0 /See Table 6A-18 for Credit Multiplier\ MINIMUMS: CENTRAL UNITS-AIR SOURCE SPLIT SYSTEM 6.8 HSPF, SINGLE PKG. 6.6 HSPF. WATER SOURCE 3.8 COP, GROUND WATER SOURCE 3.4 COP, PTHP SEE TABLES 6.6 TO 6-8. 1 FOR MULTIPLIERS FOR OTHER TYPES OF CONCRETE BLOCK CONSTRUCTION SEE SECTION 2.1 OF APPENDIX C. 2 MULTIPLIERS FOR OTHER TYPES OF RAISED WOOD ASSEMBLIES SEE SECTION 3.1 OF APPENDIX C. 3 DUCTS IN CONDITIONED SPACE NEED TO BE INSULATED ONLY TO THE R-VALUE NECESSARY TO PREVENT CONDENSATION. -5- ADDITIONAL TABLES CLIMATE ZONES 4 5 6 6A.18 HEATING CREDIT MULTIPLIERS (HCM\ SYSTEM TYPE HEATING CREDIT MULTIPLIERS (HCM) Attic Radiant Barrier HCM .98 Multizone HCM .95 Natural Gas AFUE .68-.72 .73-.77 .78-.82 .83-.87 .88-.92 .93 & Un HCM .61 .56 .53 .50 .47 .44 LP Gas HCM .77 .72 .67 .63 .60 .57 6A.19 COOLING CREDIT MULTIPLIERS CCM\ SYSTEM TYPE COOLING CREDIT MUI.tIPLlERS (CCM\ Ceilino Fans /86* ) Cross Ventilation "]"5* *Credit may be Iaken for only Whole House Fan .95* one of these system types concurrently. Multizone .95 Allie Radianl Barrier .95 Dedicated Heat Pump '}JJ L TlPLlERS (HWCM) Heat Recovery Unit 8 Solar .25' l1&1JIL A HWM MUST BE USED IN CONJUNCTION WITH ALL HWCM. SEE TABLE 6A-9. EF MEANS ENERGY FACTOR. 6A.21 INFILTRATION REDUCTION PRACTICE COMPLIANCE CHECKLIST (SEE SECTION 606\ COMPONENlS SECTION REQUIREMENTS FOR EACH PRACTICE CHECK PRACTICE II 606.1 COMPLY WITH ALL INFll TRA TION PRESCRIPTIVES. Windows Maximum of 0.34 CFM oer linear foot of ooerable sash crack (jncludes slidina alass doors\. Exterior & Adiacent Doors Maximum of 0.5 CFM oer sa. ft. of door area' solid core wood oanel insulated or olass doors onlv. Exterior JOlntS::&"cracks To be caulked aasketed weatherstripped or otherwise sealed. PRACTICE '2 l 606.1 COMPLY WITH #1 AND THE FOllOWING: (j Floors Too olate oenetrations sealed. Infiltration barrier installed. Sole olate/floor ioint caulked or sealed. Exterior Walls & Ceilinas Penetrations ioints and cracks on interior surface caulked sealed or aasketed. Ductwork Ductwork in unconditioned soace must be sealed. Firenlaces Eauiooed with outside combustion air doors and flue damoers. Exhaust Fans Enuinned with damoers. Combustion devices see 606.1.A.2 PRACTICE 13 606.1 COMPLY WITH PRACTICES #1 AND #2 AND THE FOLLOWING: Ceilinos Infiltration barrier installed. Interior Walls Too oenetrations sealed or ioints & cracks on interior walls caulked sealed or aasketed. Recessed Linhts Sealed from conditioned & insulated from ventilated attic snaces. Ductwork All ductwork located in conditioned soace. Combustion Appliances Be in unconditioned space (except direct vent). draw air from unconditioned space, exhaust by-products to outside. Combustion cooking appliances see section 606.1.A.3 I 6A.22 OTHER PRESCRIPTIVE MEASURES (must be met or exceeded bv all residences.) COMPONENTS SECTION REQUiREMENTS CHECK Water Heaters 612.1 Comply with efficiency requirements in Table 6-11. Switch or clearly marked circuit breaker (electric) or cutoff {nasI must be orovided. External or built-in heat trao reauired. Swimming Pools & Spas 612.1 Spas & heated pools must have covers (except solar heated). Non-commercial pools must have a oumo timer. Gas spa & 0001 heaters must have a minimum thermal efficiency of 78%. Shower Heads 612.1 Water flow must be restricted to no more than 3 aallons oer minute at 80 PSIG. Air Distribution System 610.1 All ducts, fittings, mechanical equipment and plenum chambers shall be mechanically attached, sealed, insulated, and installed in accordance with the criteria of Section 610. Ducts in unconditioned attics must be insulated to a minimum of R-6. Air handlers shall not be installed in attics unless in mechanical closet. HVAC Controls 607.1 Seoarate readilv accessible manual or automatic thermostat for each system. Insulation 604.1, 602.1 Ceilinos-Min. R-19. Common walls-Frame R-11 or CBS R-3 both sides. Common ceilina & floors R-l1. -6- ..;" eYe (" 7,\ ( ~I PASCO COUNTY, FLORIDA Permit No. 'I K-.71 6 Date Permitted '/ - 1~6 ~ 9-.5- Builder Name/Owner Name? A~ County Parcel No. J-5--{l6 -;L/ -3'-.3 t.? - / 0 Location J../7S-..3 ,J!~ ~ Classification/Type of Use ~t2..d.L :d~ Subd. TRANSPORTATION IMPACT FEE CALCULATION EXEMPT D Rate $ Zone No. Sq. Ft./Unit repared By Impact Fee Amount $ The above impact fee ha n established pursuant to the Pasco County rtation Impact Ordinance as adopted by the Board of C y Commissioners. This amount is payable PRIOR to the issuan of a Certificate of Occupancy or authority utilize the permitted structure, RESOURCE RECOVERY ASSESSMENT EXEMPT D RESIDENTIAL NONRESIDENTIAL No. Units I Gross Sq. Ft. (GSF) Rate/ERU - 50.00 x O,96*/Year or $0. 1315/Day ERU Assign No. Assessment - (No. Units) x ($0,1315) x (No. Days) Assessment - (GSF) x (ERU) X (0.1315) x (No. Days) 100 TOTAL FEE $ TOTAL FEE $ *Discounted for Prepayment The above assessment has been established pursuant to the Pasco County Ordinance No. 89-07 and Resolution No, 89-197, as commended. THE ASSESSMENT WILL BE CALCULATED AT THE TIME OF ISSUANCE OF THE CERTIFICATE OF OCCUPANCY. NO CERTIFICATE OF OCCUPANCY OR FINAL POWER RELEASE WILL BE ISSUED UNTIL THE AMOUNTS LISTED HAVE BEEN PAID AND RECEIPTED FOR BY A CENTRAL PERMITTING OFFICE OF fIASCO COUNTY. Acknowledgement below does not imply acceptance of concurrence, but simply receipt of a copy of this form, placing the building permit owner on notice of this assessment and the conditions of payment for same. Date Received By OFFICE USE ONLY TRANSPORTATION REC. NO, DATE RESOURCE RECOVERY REC. Noc;L 7 zj & 6,0 DATE ;}r-;kJ - tf6 BY BY d' White Applicant Canary TranslFinance Canary RRIFinance Pink Office Green Bldgllnsp feecal:ce