HomeMy WebLinkAbout96-6031
BUILDING PERMIT
BUILDING _,'
--------
CITY OF ZEPHYRHILLS
(813) 788-6611
Permit
. .~
N~ 603tj(
-<I-If- )"
Date
Property Owner:
Job Address:
Parcell.D, #
Zoning:
Description of Work
~E~C-J ~. c:~
9*!tt/91i~#;I/lf#jl.
Sewer Conn
~
Water Conn:
Water Meter:
T,I.F.'s:
FINAL
C.O,
NO OCCUPAN
DATE
Complete Plans. Specifications and Fee Must Accompany Application,
All work shall be performed in accordance with City Codes and Ordinances.
DATE
Valuation or
Contract Price
~
Permit Fee
Signature
Company
Address
City License Registration # c3.t/ I
~FO{)OO,3~1
BUILDING i
PLUMBING
MECHANICAL
Ftr.
Pre SLB
Lintel
FRM.
Insul. CL
WL
Tp. Servo
Rough In
Meter Can
Const. Pole
Pool
Pre-Meter
Final
SLB
Tub Set
Water
Sewer
Final
Breakers
Ducts Insl.
Compressor
Final
Driveway
REINSPECTION FEES: When extra inspection trips are necessary due to anyone of the following reasons, a
charge of Fifteen and 00/100 Dollars ($15.00) shall be made for each trip for each trade:
a. Wrong Address
b. Condemned work resulting from faulty construction,
C. Repairs or corrections not made when inspection called.
d. Work not ready for inspection when called.
e. Permit not posted on job site.
f, Plans not at job site,
g. Work not accessible.
The payment of inspection fees shall be made before any further permits will be issued to the person owning
same.
APPLICATION FOR PERKIT
CITY OF ZEPHYRBILLS
BUILDING DEPARTMENT
~-I- t-t,
OWNER'S NAKE ~ m c. A
OWNER'S ADDRESS .37 -z.. \ C1 -Pc..:;C.O
JOB ADDRESS -37 LIe;
~mL!l
PHONE
JltloJo (' De
/1('(' I r:cv? J(">'3 Y
R~_
BLOCK
SUBDIVISION
PARCEL 1. D. t
(OBTAIN FROM PROPERTY TAX NOTICE)
WORK PROPOSED:_New Construction _Addition -^iteration _Repair _Install
_Sign
_Move
_Deaolish
PROPOSED USE: _Single Faaily
_M/F
_' of Units _M/H
_eo..ercial
_Indust.
_Swia. Pool _Other
_Restaurant Ii Health Departaent Approval
DESCRIPTION OF WORK:
BUILDING SIZE:
x
Square Feet,
Height
RESIDENTIAL:
COMMERCIAL
ATTACH (2) PLOT PLANS Ii (2) SETS OF BUILDING PLANS Ii (1) SET ENERGY FORKS.
ATTACH (3) SETS OF BUILDING PLANS Ii (1) SET ENERGY FORKS.
PROPERTY SURVEY REQUIRED FOR ALL NEW CONSTRUCTION.
PERKITS REOUESTED
_BUILDING
$
Valuation of Total Construction
_ELECTRICAL
AMP Service
Florida Power Corp.
W.R.E.C.
---1IECllANICAL
$
Valuation of Mechanical Installation
_PL~ING GAS ROOFING
TYPE OF CONSTRUCTION: _Block _Fraae _Steel
SPECIALTY
Other
FDJISHED FLOOR ELEVATIONS:
FT.
IS PROJECT IN FLOOD ZONE AREA?
YES NO
******************************************
CONTRACTOR SECTION
BUn.DER
COMPANY
State Cert. or Regist. t
City License Registration t
******************************************
Signature
RT.RCTRICIIAH
COMPANY
State Cert. or Regist. f
City License Registration f
******************************************
SianAture
PLUMBER
COMPANY
State Cert. or Regist. f
City License Registration .
******************************************
Signature
..
Signatu
(j. /-
COMPANY e ~U {I l c:
State Cert. or Reg~st. f
City License Registration f
******************************************
v---
OTRRR COMPANY
State Cert. or Regist. .
Signature City License Registration t
******************************************
APPLICATION APPROVED BY PERMIT OFFICER.
CONDITIONS OF PERMIT AFFIDAVIT
A:- ,NOTICE OF DEED RESTRICTIONS
fhe undersigned unde~stands that this peIlit lay be subject to "deed restrictions" which lay be IDre restrictive than City
regulations. the undersigned assutes responsibility for cOJpliance witb any applicable deed restrictions.
B. UNLICENSED CONTRACTORS AND CONTRACTOR RESPONSIBILITIES
If the owner bas hired a contractor or contractors to undertake work, they lay be required to be licensed in accordance with
state and local regulations. If the contractor is not licensed as required by law, both the owner and contractor lilY be
cited for a lisdeteanor violation under state law. If the owner or intended contractor are uncertain as to what licensing
requirelents lay apply for the intended work, they are advised to contact the City of Zephyrhills Building DepartJent, (813)
788-6611.
FurtherlOre, if the owner has hired a contractor or contractors, be is advised to bave the contractor(s) sign portions of the
"Contractor Sections. of this application for which they will be responsible. If you, as the owner sign as the contractor,
you are indicating that you, rather than the contractor, are responsible for the work. If the contractor wisbes you to sign
as contractor that lay be an indication that he is not properly licensed and is not entitled to peIlitting privileges in the
City of Zephyrhills.
C. TRANSPORTATION IMPACT FEES AND UTILITY CONNECTION FEES
D. CONSTRUCTION LIEN LAW (CHAPTER 713, FLORIDA STATUTES, AS AMENDED)
I certify that I, the applicant, have been provided with a copy of .Florida's Construction Lien Law - HOIeOWDer's Protection
Guide" prepared by the Florida DepartJent of Agriculture and Consuter Affairs. If the applicant is sOleOne other than the
"owner", I certify that I bave obtained a copy of the above described docutent and prOlise in good faith to deliver it to the
"owner" prior to couencelent.
E. CONTRACTOR'S/OWNER'S AFFIDAVIT
I certify that all the inforlation in this application is accurate and that all work will be done in cOlpliance with all
applicable laws regulating construction, zoning, and land developtent.
Application is hereby lade to obtain a peIlit to do work and installation as indicated. I certify that no work or
installation has cOlleDced prior to issuance of a peIlit and that all work will be perf OIled to leet standards of all laws
regulating construction, City codes, zoning regulations, and land developtent regulations in the jurisdiction. I also
certify that I understand that the regulations of other goveI1llental agencies lilY apply to the intended IIOrk, and that it is
If responsibility to identify what actions I lUst take to be in cotpliance. Such agencies include but are not lilited to:
t DepartJent of EnviroDlental Regulation - Cypress Baybeads, Wetland Areas and Environtentally Sensitive Lands,
Water/Wastewater TreatJent
t Southwest Florida Water Hanagelent District - Wells, Cypress Bayheads, Wetland Areas, Altering Watercourses
t AIIY Corps of Engineers - Seawalls, Docks, Navigable Watellfays
t DepartJent of Health & Rehabilitative Services, EnvirODlental Health Unit - Wells, Wastewater TreatJent, Septic tanks
t US EnvirODlental Protection Agency - Asbestos abateaent
I also certify that, if fill laterial is to be used in Flood Zone "A" or "A,etc.", it is understood that a drainage plan
addressing a uCOJpensating volute" will be sublitted which is prepared by a professional engineer registered in the State of
Florida p'rior to peIlit. issuance.
A perlit issued shall be construed to be a license to proceed with the work and not as authority to violate, cancel alter, or
set aside any provisions of the technical codes, nor shall issuance of a peIlit prevent the Building Official frOl thereafter
requiring a correction of errors in plans, construction, or violations of any code. Every peIlit issued shall beCOle invalid
unless the work authorized by such peIlit is cOllenced within six IOnths of issuance, or if work authorized by the perlit is
suspended or abandoned for a period of six IOnths after the Ute the IIOrk is cOllenced. One 90 day extension of tite, lily be
allowed for the perlit with fee charge of $15.00. The extension shall be requested in writing to the Building Official. An
approved inspection lUst be logged during each six IOnth period, or the project will be considered abandoned.
WARMIHG TO MER: YOUR FAILURE TO RECORD A NOTICE OF COMHDCKHBM'I' HAY RESULf IN YOUR PAYING 'fWlCE FOR IHPROVEMENlS TO YOUR
PROPERTY. IF YOU IM'I'BlfD TO OBtAIN FINAMCIIIG, COIISULf WITH YOUR LEIIDIR OR AM ATfORIIIY BEFORE RECORDING YOUR 1I000ICE OF
COHHKIIClHEIIT. JOBS UllDER $2,500 III VALUE DO NO'I NEID fO RECORD AND POST A "NOTICE OF COMMENCEMlNI".
SIGIIATURI: MER OR AGEM'I'
SIGIIATURE: COIITRACTOR
Sf ATE OF FLORIDA
COUNIY OF
The foregoing instrument
before me this
was acknowledged
, 19__ by
STArE OF FLORIDA
COUIITY OF
The foregoing instrument was acknowledged
before me this , 19_____ by
who is personally known to me or who has
produced
as identification and who did/did not
take an oath.
who is personally known to me or who has
produced
as identification and who did/did not
take an oath.
(Signature)
(Signature)
(Name Typed, Printed or Stamped)
NOTARY PUBLIC
(Name Typed, Printed or Stamped)
NOTARY PUBLIC
FIRE ALARM SYSTEM EQUIPMENT SUBMITTAL
Item !. Qh
A 1
B 10
C ...,
..:..
D 2
D-1 2
D-2 0-:'
..:..
E 4
NOTE: ( 1)
Style !.
Descriotion
5295
Signal Power Expander
Mountino
Paoe !.
SH624-15/75-W ADA Horn & Strobe
429C
Photoelectric Smoke Det.
Surface
1
609U01-11
606U2
205B
Photoelectric Duct Det.
Remote indicator & test
3 FT. Sampling Tubes
4" Square
2
103-31
Manual Pull Station
4" Square
.,..
.,:,
To Duct
1-ga ng
To HS6.
4,5
4,5,6
4,5
1-6a ng
7
The signal power expander item A will provide 2 additional signal
circuits to support the new ADA horn & strobe lights as well as two
spare circuits for future expansion.
(2) The manual pull stations item E will be keyed identical to existing
manual pull st~tions.
(3) All submitted equipment is UL cross listed, where necessary, to the
existing Simplex 4002 system.
)
i!
ARE SYSTEMS..
SILENT
KNIGHT
FIRE ALARM
ACCESSORY
Model 5295
Signal Power Expander
FEATURES
_i
· Adds More Signal Power to Local Fire
Controls
· Aids Compliance with ADA Require-
ments Using Existing Local Control'
· UL Listed for Alarm Signal Circuits
· Two Supervised Inputs
· Four Style W (Class B) Signal Circuits
· Highly Efficient Switching Power Supply
(24 VDC at 6 Amps)
· 10 to 30 Volt Activation
· Fuseless Design
· Compatible With Most Manufacturers'
Local Controls
The Model 5295 Signal Power Expander provides
additional supervised circuit capacity for local fire
alarm systems, This makes the Model 5295 a very
cost-effective solution to meeting tough Americans
with Disabilities Act (ADA) requirements, The 5295
increases the signaling power available for the addi-
tional sounders and the brighter strobes called for by
the ADA, Meeting those requirements is easily
accomplished in a retrofit or new installation,
DESCRIPTION
The 5295 is a 24 volt 6 amp switching type power
supply housed in its own red cabinet. It contains an
integral precision battery charger capable of charg-
ing two 12 volt 6.5 amp hour batteries. The cabinet
provides ample room for field wiring and standby
batteries,
~
-3'
CONNECTION TO LOCAL FIRE
CONTROL
The 5295 can be connected to a local fire control
which utilizes polarity reversing Style W (Class B)
type signal circuits operating between 9 and 32 volts
DC, The local control signal circuit is connected to
one of the inputs on the 5295, The local control's
signal circuit end-of-line resistor is also connected
across two terminals on the 5295, which provides
supervision between the 5295 and local fire control.
Polarized audible and/or visual indicating devices
are then connected to the 5295 signal circuits using
, the 4,7K ohm end-ot-Iine resistors provided. A mov-
able shunt block allows selecting whether all four
signal circuits on the 5295, are activated by a single
input from the local control, or whether each input
activates two signal circuits, Since the 5295 draws
very little power trom the local control, it is possible
to connect one 5295 to each signal circuit, on the
local control. and still provide tull supervision ot the
signal circuits all the way back to the local control. .
SUPERVISION
LOW AC, When a Low AC condition (102 VAC or
less) is detected, the green AC POWER indicator
will turn off, It Low AC is detected for longer than 6
hours, the 5295 will open the Signal 1 and Signal 2
input loops, causing the local control to go into trou-
ble, These conditions will restore when AC returns
to 108 V AC or higher,
LOW BATTERY, When a Low Battery condition,
20.4 VDC or less, is detected, the yellow BATTERY
indicator will turn on and the 5295 will open the
Signal 1 and Signal 2 input loops causing the local
control to fJo into trouble, These conditions will restore
wi:len battery voltage returns to 22 VDC or higher,
SIGNAL CIRCUIT TROUBLES, The 5295 has four
Style W (Class B) signal circuits, The signal circuits
are supervised against opens or shorts and will con-
tinue to operate normally during ground fault condi-
tions. When the movable shunt block is in the single
input position, a trouble condition detected on any of
the four signal circuits will cause the Signal 1 input
loop to open, causing the local control to go into trou-
ble, When the movable shunt block is in the dual input
position, a trouble condition detected on signal cir-
cuits 1 or 2 will cause the Signal 1 input to open, A
trouble condition on signal circuits 3 or 4 will cause
the Signal 2 input to open, When the signal circuit
trouble condition is corrected, the appropriate Signal
loop input will restore to normal.
SPECIFICATIONS
ELECTRICAL SPECIFICATIONS
· AC Input: 120 V AC at 2 amps
· Output: 24 VDC at 6 amps
· Built-in battery charger for 2 to 12 volt 6.5 amp
hour batteries will provide 24 hour standby with 15
minutes in alarm
· Low AC: 102 V AC for 6 or more hours
· Restore Low AC: 108 V AC
. Low Battery: 20.4 VDC
· Low Batt Restore: 22 VDC
. Signal 1 & 2 inputs: 9 to 32 VDC
· Signal circuits: 20,3 to 27.3 VDC at 1,5 amps each,
4,7 K ohm EOL resistor required on each circuit
INDICATOR LIGHTS
· AC Power On - Green
· Battery Trouble - Yellow
· Signal 1 Trouble - Yellow
· Signal 2 Trouble - Yellow
· Signal 3 Trouble - Yellow
· Signal 4 Trouble - Yellow
MECHANICAL SPECIFICATIONS
· Dimensions: 12-1/4 inches W x 16 inches H x
3 inches D
(31.1 cm W x 40.6 em H x 7,6 cm D)
· Shipping Weight: 8 Ibs, 14 oz, (4 kg,)
· Color: Red
APPROVALS
· UL Listed - UL864
· NFPA -72A
· California State Fire Marshal approval pending
· NYC MEA (BSA) approval pending
· Other approvals pending
SIGNAL CIRCUIT
OUTPUT
..:"';-'c
kit .
:.h-t\t5~ LOCAL FIRE CONTROL ~:
~(1t";6"
:fit..,. .... .,,,..k<<
'r..,. '~I'-'''''~'''''.''' -', v-"_, ....~.....'."...: '. ..,.....,.,..."'..ir,'t'i:1J."ht'=_.I............. ..tc.........I"I~t:. ~.....~
ty~~i~:~~,;~:;~.')i:;~J.~;::~t.l~2~;i~~~~-=.~;;~~~;. :;;..~;t<::.::;;,t. '~;::;~r. ..~.... ~ - 0-,0
LIGHTNING PROTECTION: Silent Knight guarantees this product against lightning strikes! We will repair or
replace the Silent Knight equipment, if necessary, should lightning disable it during the one-year warranty period, It's
just another reason why Silent Knight has been a nationwide leader in electronic security for 25 years,
~ SILENT
~ ~~~;:~
7550 Meridian Circle, Maple Grove. MN 55369-4927
1-800-446-6444 or in Minnesota (612) 493-6435
Fax: (612) 493-6475
THE QUALITY EDGE
MADE IN
AMERICA
Form No, 150781 (3/93)
~
GENTEX
)
4" Electronic Horn HG or SHG Series
Applications
4" low frequency electronic horn and
horn/strobe that meets code requirements
for supervised fire alarm systems for the
hearing impaired and ADA,
The HG/SHG series are quality elec-
tronic signaling appliances that offer you
both dependable evacuation signals and
visual alarms or a combination of both by
simple terminal wiring, The SHG series
can also be wired to have independent
operation of both horn and strobes, (See
wiring diagrams), This can be simply
done by removing two jumper plugs locat-
ed on circuit board. (See installation
manual for details,)
The HG/SHG series are easily field
changeable from a steady low frequency
alarm signal to a pulsing low frequency
alarm signal by simply removing a jumper
plug, Changing from steady tone to puls-
ing tone does not prevent reverting back
to original tone at a later date. All units are
shipped from the factory in the steady
alarm mode,
The HG/SHG series are designed to
be used for both new construction or
retrofit projects by easily mounting to 4"
electrical boxes or 2 gang old work boxes
(see back for details),
All HG/SHG appliances are UL 464/
1971 listed for use with fire protective
systems and are warranted for 2 years
from the date of purchase,
SERIES
SHG
Approvals
HG
@
MEMBER
C~)
. Americans with Disabilities Act (ADA)
. BFP
· BSAlMEA #412-91-E
. CSFM #7135-569:115
. NFPA 72
. UL 464
Standard Features
i . Low frequency output.
~, . Low current consumption 17mA @
nominal voltage, (HG124)
. Wide voltage range,
· Screw terminals, separate in/out wiring
option for both hom and strobe,
· Steady or pulsing tone,
Available Models
· Textured finish high impact plastic
faceplate,
. Wide variety of mounting options for new
construction and retrofit applications,
. Supplied with beauty plugs to accom-
modate a variety of installations,
. Xenon Strobe maintains constant flash
rate (1 per sec.) regardless of input
voltage,
· Flush or semi-flush mounting without
the need of a trim plate,
. 15/75 and 30/75 candela strobe op-
tion, Meets ADA 4.28,3 requirements,
· AII11 Oed models exceed requirements
of 4.28,3 of the ADA.
. UL 464/UL 1971 listed for fire protective
service/signal for hearing impaired,
Combined Rated Combined Rated
Current Current
Light Effective @ Nominal @ Maximum
Model Operating Flash Intensity In Operating Operating
Number Voltage Rates/Min Candela Voltage Voltage dB @10 Fl.
HG124 10-30 - 17mA 21mA 100
,- .' -~~'1~ ':.........:.. .. ':k '1-:''X-'~ ':~Ar~~*~~~~,,:::'?c'":~';'~:~:
SHG12-15-1 10- 16 60 15 130mA 102mA 90
SHG12-15175 10-16 60 15 (UL 1971) 252mA 173mA 90
75 (UL 1638)
~ ' ' I'!~~~~:~-::;~;~~'">l~
SHG24- 15-1 21-30 60 15 I 95mA 90mA 95
SHG24-15175-W 21-30 60 15 (UL 1971) 122mA 108mA 95
75 (UL 1638)
SHG24-30175-W 21-30 60 30 (UL 1971) 159mA 135mA 95
75 (UL 1638)
SHG24-15175-C 21-30 60 15 (UL 1971) 137mA I 121mA 95
75 (UL 1638)
SHG24-110'1 21,30 60 110 237mA 200mA I 95
Note: 24VDC 15 candela units have a start-up current of 11 4mA at 1 flash per second,
15175 candela units have a start-up current of 130mA (wall)
15175 candela units have a start,up current 01140mA (ceiling)
30175 candela units have a start-up current 01 120mA
110 candela units have a start-up current of 148mA
\
j
J
WHEN PLACING AN ORDER: add the following to the end of the model number:
.W' Wall mount and 'R": Red faceplate
.P' Plain (no lettering) .W": Off-White faceplate
.C' Ceiling mount (1575 models only)
I
I, MADE IN THE
U.S.A.
GENTEX
Architect & Engineering Specifications
The audible or audible/visual signal shall be Gentex model HG
or SHG or approved equal, and shall be listed by Underwriters
Laboratories per UL464, and when combined with the strobe
option the strobe shall be listed per UL 1971. The notification
appliance shall also be listed with the Califomia State Fire Marshal
(CSFM) and the Bureau of Standards and Appeals (NYC),
The notification appliance shall produce a peak sound output of
90dBA or greater as measured in an anechoic chamber.
The maximum current consumption at 24VDC for the audible
only shall not exceed 17 milliamps and the maximum current
consumption forthe combination audible/visual notification appli-
ance when utilizing a 15cd strobe shall not exceed 95mA at
24VDC,
For those applications requiring the higher output in light
intensity, the maximum current consumption at 24 VDC shall not
exceed the combined current consumption of audible with the
following visual with each candela: 15f75cd shall not exceed 122
milliamps, 30f75 shall not exceed 160 milliamps, 11 Ocd shall not
exceed 237 milliamps,
The visual signal shall have a flash rate of 1 Hz regardless of
input voltage,
The notification appliance shall be provided with screw termi-
nals for in and out field wiring and the strobe shall be capable of
operating independently after the audible has been silenced,
The notification appliance shall be capable of mounting to a 4"
square back box and a 2 gang switch box of a minimum of 2 1 /8"
Mounting: 4" Square boxes w/brackets 2'/8" deep minimum in depth, 24 units per carton
4" square metal/non-metallic switch/outlet boxes 2'1a" deep minimum 11 pounds per carton HG
Gangable 2 gang switch/masonry outlet boxes 2Ye" deep minimum 16 pounds per carton SHG
Wiring Diagrams
" HG HOilh AND SriG SERIES POWERED IN PARALLEL
L.lllSTED
a:MRCl.
_c
~
~
CRQJi1
\'
SERIES
Dimensions:
~
.00 ~'"'
B SHG se~IES WITH HORN AND STROBE POWERED INDEPEND,NTlY
.OU' REMOVE CIRCUIT COVER HOUSING AND REMDVE JUMOfRS , AND 2
R;>tACE COVER AND PROCEED TD WIRE HORN INTO CIRCUIT
I.K USiEC
CONTROL
~AJ\'f,-
SLPERVISED
STGNAL
o~c II
EDlR
NOTE: POWER IS SUPPU::D TO DEVIC:S WHEN CONTRDL PANEL IS LATCHED
~
, '0
~
.
NOTE: Supplied with beauty plugs to accommodate a varrety of installations,
GENTEX
CORPORATION
Fire Protection Products: 10985 Chicago Dr,
Box 310, Zeeland, MI 49464
616/392-7195, FAX: 616/392-4219
~
t. ~ Printed on Recycled Paper
GX120491-16
E'
S
L
N
PRODUCT
:)
N FOR MAT
-)
· Intelligent, self-diagnostics
· Field replaceable optical chamber
· Low-profile design
· Plug-in terminal block
· Advanced false alarm immunity
\
)
o N
B U L LET
429 SERIES
Self-Diagnostic,
Two-Wire,
Photoelectric
Smo'(e Detectors
Model numbers: 429AT, 429C, 429CT,
429CRT, 429CST, and 429CSST
~
LISTED
<8>
APPROVED
California State Fire Marshal Approved
MEA (New York City)
The ESL 429 Series self-diagnostic, two-wire
smoke detectors continually monitor their own
sensitivity and operational status, and provide a visual
trouble indication if they drift out of sensitivity range
or fail internal diagnostics, This meets NFPA 72 field
sensitivity testing requirements without the need for
external meters,
Additional diagnostic information is activated by
applying a magnet near the detector's integral reed
switch, This initiates a self-diagnostic routine and
provides visual indication of sensitivity level, or if service
is required,
The 429 Series is easily 'cleaned by simply replacing .
ESL's proprietary field-replaceable optical chamber, All .
models are designed to reduce false alarms from dust.
insects. RFI and external light.
An integral combination rate-of-rise and fixed 13soF
(SrC), 50-foot rated, heat sensor is available with all 'T
model detectors (see selection gUide). An integrated
silicon heat sensor and a dedicated microprocessor are
used to detect heat and perform the rate of rise calcula-
tions, for earlier heat detection,
continued
Designator Feature Description
Isolated Fixed Temp, Isolated fixed 1350F (570C) and rate of rise heat detector, independently trips the LED and alarm
relay output. Smoke detector activates internal sounder (local alarm) and auxiliary relay, but
H and Rate of Rise Heat does not latch, Approved as both single station smoke alarm and system heat detector. Ideal for
Detector hotel, motel and dormitory rooms where smoking is allowed,
R Auxiliary Relay Used to activate other devices such as elevator recall, door holders, strobes, etc, Listed for .
releasing service,
.
S Built-in Sounder 85db built-in sounder alarms when smoke is detected or when power wiring polarity is reversed,
Built-in Sounder with 8Sdb built-in sounder alarms when smoke is detected or when power wiring polarity is reversed,
55 Sensitivity Status Also, chirps when unit goes outside the approved sensitivity range for more than one day,
Output Resetting detector will silence chirp for one day, until unit is restored to proper sensitivity,
Integrated Fixed Integrated fixed 13soF (srC) temperature and rate of nse heat detector offers double protection,
T Temp, and Rate of Either heat detector or smoke detector can trip and latch LED and alarm relay outputs,
Rise Heat Detector
!;:SL 429 Series Smoke Detectors
Architectural and Engineering Specifications
The ESL 429 Senes low-profile, self-diagnostic, two-wire smoke
detectors work on me light scattering principle, A pulsed
infrared light-emitting diode serves as the light source, and a
high-speed photo-diode as the sensing element. When the
amount of light reflected onto the photodiode reaches the
sensitivity setting, the smoke sampling rate increases, Three
(3) successive smoke sensings above the sensitiVity setting are
reaulred to sound an alarm, This design has superior
protection against false alarms caused by dust. insects, RF and
ambient-light.
A confirmed alarm causes the normally flashing power
indicator LED to light continuously and the optional alarm
relay /available in "R" models) to operate, A trouble indication
is automatically displayed by flashing the LED every second,
This meets NFPA 72 field sensitiVity testing requirements, An
Internal 85 dB horn (available in .5" models) emits a steady
tone when the detector alarms and a pulsed tone when
power polarity is reversed, Also available is the "55" model
which chirps when the unit goes outside the approved
sensitivity range for more than one day, Resetting the detector
will silence chirp for one day, until unit is restored to proper
senSitivity,
Product Data
Sensitivity, " , , . " ' , , , , " , ' , , , , ,. , , , , , , , , , , , ' , , " . , "max ,,'"
min,..
Operating temperature range ..'................,..
3,1 - l,O%/ft,
3,) + O,50%/ft.
320F to 1200F
OOC to 500C
Operating humidity range ...........,...........,......, 0 to 95% RH
Minimum voltage _..e, Q, CRT. CST, CSST ...,............... 8,5 V
.N.,.""""",."",."",."""""""".."" 6,5V
Maximum voltage. C. Q, CRT, CST, CSST '....'......,...... 33 V
-AT ...............,....,.,....,.......,....,.......... 20 V
Maximum ripple (peak to peak) ,..........,..,......,........,..... 10%
Typical average standby current ........,...........,..........., 70 J..lA
Field wiring size..,........,.....,...,.,........,...,.,....,... 14 - 24 AWG
Selection Guide
The proprietary optical sensing chamber is field replaceable,
allOWing quick and easy cleaning and maintenance,
Models with auxiliary relays are approved for releasing service,
The very Jow profile 429 Series detectors are equipped with a
hinged cover, a concealed tamper-resistant latch, and insect
screens,
All winng terminates in plug-in, clamp-type screw terminals,
The detectors mount to a standard single-gang electrical box,
a four'lnch octagonal, four-inch square electrical box, or
W/REMOLD No 5739 fixture box,
Smoke Detector Spacing
On smooth ceilings (as defined in NFPA 72), spacing of 30
feet (9,1 meters) may be used as a guide, Other spaCIng may
be used depending on ceiling height. high air movement,
and other conditions or response requirements,
'~.~I\= =) ".,J=,w
-=1 0 =-
Alarm current.... draws max of 60 mA if not limited by panel
Max, avg, polarity reverse current - CST ..........,.......... ) 0 mA
Sounder specifications .........,......................... 85 dB at ) 0 ft.
Heat detector specifications
fixed temp, ................,......... 1350F:!: 50F (57,rC:!: 2,80C)
rate of rise .., 150F/min, & > I 050F (8.30C/min, & > 40,60C)
Relay specifications .............,....... 2A @ 28 V DC or 120 V AC
PaCkaging ....., 10 detectors are packed In a carton
Color ..,....,....,......,........,..,..,...,.......' white cover/white base
with UV inhibitor to prevent yellOWing
2-wire compatibility .................,., see ESL Compatibility Index
listings UL 268, FM. CSFM and MEA (New York City)
for Canadian ULC listed products use 428 series
CORPORATE HEADQUARTERS
] 2345 SW Levelon Dr.
Tualalln, OR 97062
Tel.. 503,692,4052
Fax: 503,691.7566
U,S, '" Canada: 800.547.2556
Technical Service: 800,648,7424
ESLN
A PRODUCT OF SENTROL, INC
Scntrol. Ine. reserves the righl
10 change specihcallons
WllhOUl notice,
(f)] 995 Senlrol. Ine.
E.) HH3.0305,I'I.C 15~
600 SERIES
ACCESSORIES
DESCRIPTION
The 606 Series remote indicators are designed for use
with the ESL 600 Series area fire detectors and the ESL
609 Series air duct-type smoke detectors, Model 606U1
is a remote indicator only, Model 606U2 features remote
indicator and key operated test switch, Model 606U3
features remote indicator and key operated test and
reset switch, A single key (Hudson Cat. 30) is supplied,
The terminal numbers on the remote indicators match
terminal numbers on ESL 600 Series area fire detectors
and 609 Series air duct-type detectors, Combination tri-
wall barriers and captive wire clamping plates ensure
secure wiring connections,
All models are constructed of high-impact thermoplastic,
Their decorative design and multi-colored labels make
the 606 Series attractive accessories,
APPLICATION
)
ESL 606 Series remote indicators are ideal for use in
applications where ESL 600 Series fire or air duct-type
detectors are not readily visible or accessible (Le.,
installed in plenums, above suspended ceilings, below
raised floors), Model 606U3 is primarily used to provide
reset for detectors that are u~ed for releasing service,
and that are not connected to a fire alarm control unit.
INSTALLATION
The 606 Series mount to a standard single-gang
electrical switch box with a minimum depth of 1-3/8
inches (3.43 cm), Mounting screws are supplied, All
wiring connections must be made to the remote indicator
before mounting it to the switch box,
APPROVALS
Listed by Underwriters Laboratories, Inc,; California
State Fire Marshal approved (Listing #7300-447:118),
REMOTE INDICATORS
MODEL
DESCRIPTION
606U1
Remote indicator
\
J
606U2
Remote indicator with test
606U3
Remote indicator with test and reset
t'
H"..""..ln<IKiBI<"
" .
"-a
~--
.,.-
\W"-
.
<8>
-.
Calitornia Slale
Fire Marshal
Approved
b
eSt
Remote Indicators
I~-j
@
FEATURES
· Remote alarm indication
· Optional remote TEST and RESET functions
· Easy wiring connections to ESL 600 Series
area and duct-type detectors
· Fits standard single-gang electrical boxes
· Wire clamp-type terminals
· Keyed alike to ESL control units and ESL
pull stations
· High-impact thermoplastic
· Attractive design
PRODUCT DATA
Height:
Width:
Depth:
Distance between screw holes
(center to center):
Indicator rating:
Switch rating:
Single key supplied,
4-1/2 in, (11,25 cm)
2-3/4 in, ( 6.88 cm)
1-3/8 in, ( 3.43 cm)
3-9/32 in, (8,20 cm)
6 VDC, 5 mA
4 A, 125 VAC
, ,
600 SERIES ACCESSORIES
DIMENSIONS-ALL MODELS (Model 606U3 shown)
4,112"
Front View
I~
2,3/4"
"
I ~ /11
\
le;- ii' I
g - q" ~ . c I
0
II 3-
NORMAL
~:::
1/ CQ) \
SCHEMATIC DRAWINGS
820 ohms
Model 606U1
04
05
820 ohms
Model 606U2
E'5l
SENTROL, INC,
10831 SW Cascade Blvd,
Portland, OR 97223
Sales: 800,547,2556
Fax: 503-684,9230
Technical Support: 800-648-7424
Bulletin 2270,54 September 1992
Appearances and details subject to change without notice,
9/32"
04
05
06
Distributed by:
Side View
~1-3/8"
820 ohms
o~
1~
test
Model 606U3
04
05
06
E.SL Initiating Devices
103 Series ' , . , , , . , , ,
Manual Fire Alarm Stations
I
. Single and dual actioll pull stations
· Terminal or pigtail connections
· Semi-flush or surface mounting
Listings
. CSFM approved
· UL approved
NYC BSA approved (103-22, 103-22S
and 103-24)
~
LISTED
103-20
103-21
103-22
103-22S
103-23
103-24
103-31
103-32
103-42
103-60
103,80
Accessories
103-25
103-26
Single action (SPST) with hex reset
Single action (DPST) with hex reset
Dual action (SPST) with hex reset
Dual action (SPST) with hex reset and NY stripe
Dual action (DPST) with hex reset
Dual action, pre-signal (DPST) with hex reset
Single action (SPST) with key reset
Single action (DPST) with key reset
Dual action (SPST) with key reset
Weatherproof, single action (SPST) with key reset
Explosion-proof, dual action fDPDT) with key reset
Red, surface back box for 103-20 through 103-42
Replacement glass rod for 103,20 through 103-60
104 Series ' , , , , , , .
Heat Detectors
/~.,
.'1 ~
~ .
~ .'.~.
. "
r~
.j-
. . '
Listings
. CSFM approved
. LlLS21
. New York, Board of Standards and
Appeals approved
. Complies with NFI':\ 7?
~
USTED
'"":~DeSCriptionA~1.~4..if.;':~;
t~";~:~;.~~1'~~:::-l~'!;
,'~~"",'$.".jl~.'l;.~_ "t:~t~\,tyM;,
1350F (5rC). fixed temperature/rate-of-rise heat detector: single circuit
1940F (90oC). fixed temperature/rate-of-rise heat detector: single circuit
1350F (5rC). fixed temperature heat detector; single circuit
1940F (90oCI. fixed temperature heat detector; single Circuit
~
1,800.547,2556 SENTROL, INC
.~
+
t:5'
609 SERIES
AIR DUCT SMOKE DETECTORS
DESCRIPTION
The ESL 609 Series Air Duct Smoke Detectors consist of an ESL 600
Series photoelectronic or ionization smoke detector head, a Model
609UOO duct detector housing, and one selected function card, The
interchangeable sensing head and function card configuration allows
great flexibility in product application,
The assemblies feature a modular design that allows easy selection
of the desired signaling and control functions, The rugged mechani-
cal design includes a manifold and a clear partitioned cover that
directs all sampled air through the sensing chamber of the selected
smoke detector.
The clear partitioned cover allows viewing of the UNJOUEintegral air
flow monitor which indicates the presence and direction of air flow
through the sensing area of the enclosure, Additionally, the cover
includes a probe port for in-place measurement of the actual air
velocity using an anomometer. The air inlet filter may be visually
inspected through the clear cover for dust and dirt accumulation,
A solid steel conduit mounting plate features knockouts for 1/2 and
3/4 inch conduit and provides continuous grounding between con-
duits, Integral inlet and exhaust sampling tubes, which are suitable
for duct widths of six or more inches, are provided, OPTIONAL
extension sampling tubes are available in two, four, and eight foot
lengths,
This product is approved for use without additional extension
sampling tubes.
NOTE: In some applications, the addition of an optional extension
sampling tube may cause the air flow monitor to stop rotating, This
is a result of the lesser air volume being sampled with the optional
extension tube, mostly attributable to its smaller inside diameter.
Standard features also include a local red LED alarm indicator, local
functional te~t capability, and a continuity switch for checking the
system wiring,
The integral compartment accepts one electronic function card,
Each function card is provided with barrier-type, clamping-plate,
screw terminal strips to accept field wiring connections of wire sizes,
12 AWG through 18 AWG, These terminal strips are designed to
prevent "looping" of wires and provide for supeNision of conductors,
Function cards are available in several configurations. Please refer
to pages 2 and 3 for electrical specifications.
APPROVALS
The ESL 609 Series Air Duct Smoke Detectors are for use in commer-
cial fire protective signaling systems, NFPA 71 and 72 (formerly
designated as 72A, 728, 72C and 720). and in commercial air
conditioning and ventilating systems (NFPA 90A), Listed by Under-
writers Laboratories, Inc,; California State Fire Marshal Approved
(Listing #3240-447:120); New York City, Board of Standards and
Appeals approved (Calendar No. 122-73-SA); State of Maryland
approved (Permit #1905); City of Cleveland approved (Docket S-5-88),
California State
Fire Marshal
Approved
Patented
<~
~=:--T'" -.~ - ".~~
.- ~~f
^
FEATURES
@
· Photoelectronic or Ionization Detection
~'Requires NO Extension Sampling Tubes
· UNIQUE Visible Air-Flow Indicator
· Two-wire 12/24 VDC Operation
· Four-wire 120 VAC, 24 VDC, 24 VAC Operation
· Modular Design
· Transparent Housing Covers
· Local Reset Capability
· Local Test and Alarm LED
· Remote Alarm, Test and Reset Capability
· Optional Auxiliary Alann Contacts
· Optional Supervisory Contacts
· Listed to UL 268A
APPLICATION
The function of an air duct smoke detector is to detect smoke for the
primary purpose of controlling air movement by air conditioning and
ventilating systems, in an attempt to prevent panic and damage from
the distribution of smoke and gaseous products,
The interchangeable detector configuration allows great flexibility in
product application, The ESL 600 Series smoke detectors are suited
for commercial, industrial, institutional and residential fire alarm
systems,
Electronic function cards provide for two-wire and four-wire operation
for alarm initiation and/or releasing seNice applications, Two-wire
detectors must be connected to UL Listed compatible initiating cir-
cuits, Four-wire function cards for low voltage DC operation, may also
be operated from a nominal 24 VAC power supply, commonly avail-
able in many HV AC applications, For more application information on
the 609 Series function cards, refer to pages 2 and 3,
EQUIPMENT
The ESL 609 Series Air Duct Smoke Detector consists of three
primary elements: a) the sensing head, b) the selected function
card, and c) a housing for the detector and function card,
Duct Detector Housing
The base section of the housing that mounts to the duct wall
includes: a) integral inlet and exhaust sampling tubes. b) a
sensing head mounting base with an automatic-opening continu-
ity switch, c) a conduit connection plate with ground screw, d) the
detector cover/manifold monitor, and e) the function card com-
partment cover.
The 609U01 is an air duct detector enclosure supplied with a
611 UD photoelectronic smoke sensing head, The 609U02 is
supplied with a 612UD ionization smoke sensing head,
Electrical Function Cards
Any ofthe function cards may be used with the Models 609U01 and
609U02 duct detector assemblies, All function cards include a
local alarm (red) indicator, local test capability, and provision for
remote test and remote alarm indicator connections, All models
except 609U10 include a remote detector reset capability, All
models with auxiliary alarm contacts are Listed as suitable for
releasing service applications,
Two-Wire Applications
Three function cards are currently available for two-wire alarm
initiating use, Two-wire detectors must be connected to Listed
compatible initiating circuits, Two-wire function cards do not in-
clude a power-on LED (green), Electrical specifications are shown
in Table 1, below,
Table 1: Electrical Specifications - Two-Wire Function Card Application, Low Voltage DC
:~.;.' ..t"in.~:!~: ~".~ii~'~~! r ~'~~!:"",'i Voltage i. ; Voltage
:. .Model;t Compatibility Range Range Standby, 'Alarm Alarm
',Number .!~~~.Identlfler' r Current ' Current Contacts 1
Standby :!!.! Alarm
~;.-~"f;;,~'.~.~.:,~ \1 !r~(~~:':';~.: ~~.~!..'.- :.t' ._~ ..
609U10 SOD 8.5-44 VDC 33 VDC max, 50 uA max, 60 mA max, None
609U11 502 8.5-44 VDC 33 VDC max, 50 uA max, 60 mA max, 1A, 1C (2 Amp)
609U12 536 8,5-44 VDC 33 VDC max. 2
50 uA max, 70 mA max, 1A (2 Amp), 2C (10 Amp)
1, Relay contact ratings shown are for a resistive load at 30 VDC or 120 VAC maximum,
2, When the Model 609U12 function card is used in a two-wire initiating circuit application, the 10 ampere relay must NOT be programmed
for normally operated releasing service, If the relay were to be programmed in this manner, the standby operating current would be
increased from 50 microamperes to 10 milliamperes,
Low Voltage, Four-Wire Applications
Seven function cards are currently available for low-voltage. four-
wire alarm initiating and releasing service use, or stand-alone
releasing service applications, All of the low voltage four-wire
function cards can be powered from a nominal 24 VAC source,
available in many HV AC applications, Electrical specifications
are shown in Table 2, on the following page,
Line or Low Voltage, Four-Wire Applications
Four function cards are currently available for line voltage (Le"
120 V AC nominal), four-wire alarm operation, All four function
cards can be field modified for low voltage, four-wire opera-
tion by cuttIng Jumper J12 located In the upper right-hand
comer of the function card, below terminals 0 and 1. Four-
wire LinelLow voltage function cards INCLUDE a power-On LED
(green), Electrical specifications are shown in Table 3, on the
following page,
220/240 V AC Function Card
The Model609U25 function card is currently the only function card
available for 220/240 VAC, four-wire operation, Electrical speci-
fications are shown in Table 3, on the following page, .
Field Programming of the 10 Ampere Contacts for Releasing
Service,
As supplied, the two, 10 Ampere rated, Form C auxiliary contacts
provided with function cards 609U12, 609U 14, 609U22, 609U24,
609U25, 609U32, and 609U34 transfer on alarm ONLY, The relay
that controls these contacts may be field programmed. by moving
jumper J10 from pin P8 to P7, to be energized in the normal
standby condition, so that the contacts transfer on removal of the
sensing head, loss of power to the air duct detector assembly, or
alarm of the sensing head, This may be desirable in many
releasing service applications,
.:s
Table 2: Electrical Specifications. Four-Wire Function Card Application, Low Voltage AC or DC
Voltage 2 Amp 10 Amp 1 Amp Power-On
Model Ran~e I Standby Alarm Alarm Alarm SU8:rvlso~ LED
Number Stan by Current Current Contact3 Contact 3 ontact . (green)
609U11 8,5-33 VDC 50 uA 48mA 1 Form A - - -
24 VAC 1 Form C
609U31 8,5-33 VDC 9mA 57 mA 1 Form A - - y
24 VAC 1 Form C
609U12 n -33 VDC 50 uA 59 mA 1 Form A 2 Form C - -
24 V AC (11 mAl' (48 mA)'
609U32 17-33 VDC 9 mA 68mA 1 Form A 2 Form C - y
24 V AC (20mA)' (57 mAl'
-.
609U33 17-33 VDC 17 mA 65mA 1 Form A - 1 Form A Y
24 VAG 1 Form C
609U14 17-33 VDC 8mA 67 mA 1 Form A 2 Form G 1 Form A -
24 VAC (19 mAl' (56mA)'
609U34 17-33 VDC 17 mA 76 mA 1 Form A 2 Form C 1 Form A Y
24 V AC (28 mA)' (65 mAl ,
1, The 10 Ampere contact relay of the 609U 12, 609U 14, 609U32 and 609U34 function cards can be field programmed to be normally operated, and
to release on alarm, sensing head removal or power loss, by moving jumper Jt 0 from pin P8 to pin Pl, If the relay is programmed in such a manner,
the standby current @24 VDCN AC is increased by 10 milliamperes, and the alarm current is reduced by 10 milliamperes, as shown in parenthesis,
2, The Form A supervisory contact is closed with power applied,
3, Relay contact rating shown are for a resistive load at 30 VDC or 120 VAC maximum,
Table 3: Electrical Specifications. Four-Wire Function Card Application, Line Voltage AC or Low Voltage AC or DC
Model Voltage Standby 2 Amp 10 Amp 1 Amp
Ran~e Alarm Alarm Alarm SU&ervlso~
Number Stan by Current Current Contact3 Contact 3 ontact2.
609U21 102-132 VAC or 15 mA 20 mA 1 Form A
17 -33 VDC/24 V AC 1 1 Form C
609U22 102-132 VAG or 15 mA 20mA 1 Form A 2 Form C
17 -33 VDC/24 V AC '
609U23 102-132 VAC or 15mA 20mA 1 Form A 1 Form A
17 -33 VDC/24 V AC' 1 Form C
609U24 102-132 VAC or 15 mA 20 mA 1 Form A 2 Form C 1 Form A
17 -33 VDG/24 V AC 1
609U25 187-242 VAC 5mA 10 mA 1 Form A 2 Form C
I -
1. For Models 609U21, 609U22, 609U23, and 609U24, when converted in the field for low voltage operation the electrical specifications of the similiar low
voltage card in Table 2 apply, For example, il you convert a Mode/609U2t for low voltage operation use the specifications of a 609U31, For a converted
609U22, use the specifications of 609U32, etc,
2, The Form A supervisory contact is closed with power applied,
3, Relay contact ratings shown are for a resistive load at 30 VDC or 120 VAC maximum,
Sampling Tubes
A pressure differential pulls air in through the inlet sampling tube
and into the sampling chamber, then sends it back out into the duct
through the outlet sampling tube,
Each duct detector housing is equipped with 5.25 inch inlet and
exhaust sampling tubes, The ends of these tubes are cut at a
450angle, The inlet tube faces upstream and the exhaust tube
faces downstream to ensure airflow through the housing, The
tubes provide the means of obtaining a sample of air from the duct.
Although this product Is approved for use without additional
extension sampling tubes, optional tubes may be required by the
authority having jurisdiction, OPTIONAL sampling tubes are
available in several lengths,
609 Series Air Duc,t Smoke Detectors
Table 4: Contents of Pre-packaged Duct Detector Models
Pre-packaged Model Number Sensing HeadIType Function Card 1
609U01 611 UD Photoelectronic None
-
609U02 612UD Ionization None
609U01-11 611 UD Photoelectronic 6G9U11
609U02-11 612UD Ionization 609U11
1-- ---_." I -----
609U01-24 611 UD Photoelectronic .'9U24 j
609U02-24 612UD Ionization 609U24
.------.--- -------
609U01-31 611 UD PI10toelectronic 609U31
_ __'~'___,"_n. ._________.________ , - - , __ "__.-0 ----- --".- -- -------- ------ ----no -~_, . _ '. i
609U02-31 612UD Ionization 609U31 Ji
_ =:::J
1, For electrical specifications of function cards, see Tables on previous pages,
PRODUCT DATA
Accessories Dimensions:
Length: 16,5 in, (42 cm)
All function cards provide for remote alarm indicator and/or remote Width: 5,5 in, (14 cm)
test capability when used in conjunction with the ESL 606 Series Depth: 4,0 in, (10 cm)
accesories: Model 606U1 Remote Alarm Indicator or Model 606U2 Integral sampling tubes extend the width by 5,5 inches and require two
Remote Test and Alarm Indicator, All four-wire function cards holes of 2 inches diameter for clearance
include an extra terminal to facilitate connection of a local or remote Weight: -
detector alarm reset switch for use with the ESL Model 609URS Maximum weight is 78,75 oz, (2.23 kg.)
Reset Switch or Model606U3 Remote Alarm Indicator with Remote Operating Temperature Range:
Test and Reset. See Table below lor additional accessories. 0-500C, 32-120oF
~- - Operating Duct Air Velocity Range:
Model Description 300-2000 ft./min, when the 612UD is installed within the duct housing
Number 300-4000 It./min. when the 611 UD is installed within the duct housing
606U1 Remote Indicator SPECIFICATIONS
606U2 Remote Indicator with Keyed Remote Test This Air Duct Detector shall be either an ESL Model 609U01 Photoelec-
tronic Detector, Enclosure assembly or an ESL Model609U02 Ionization
606U3 Remote Indicator with Keyed Remote Test Detector, Enclosure assembly,
and Reset
1---,- n, The base 01 the enclosure and the manilold shall be constructed 01 solid
205A Inlet Sampling Tube Extension-2 ft. structural loam, and shall incorporate an air-tight smoke chamber in
-- compliance with UL268A, Standard lor Smoke Detectors lor Duct Appli-
2058 Inlet Sampling Tube Extension-4 It. cations, The detector enclosure shall be equipped with an integral
--- --
205C Inlet Sampling Tube Extension-8 It. mounting base capable of accomodating either a photelectronic or ioniza-
--- tion detector head and shall be capable of local testing via a magnetic
605A3 Test Tool switch. The clear covers lor the enclosure shall be constructed of Lexan,@
~ -- -----
204A Power SuperviSion Unit 12 VDC systems The detector shall operate at air velocities 01 300 leet per minute to 2000
Power Supervision Unit 220. V AC systems leet per minute utilizing a 612UD sensing head, and 300 - 4000 leet per.
910-4 minute utilizing a 611 UD sensing head, The duct detector shall be
- ------- -
609URS Local Reset Switch, N/C with 6" Leads capable of intertacing directly with ESL 606 Series Remote Stations-
which shall provide lor local alarm indication and test functions, Local or
Remote Reset capability shall be provided for utilizing the Models
~eplacement Parts 609URS or 606U3 respectively,
Model Number L Description 1 An integral lilter system shall be included to reduce dust and residue
accumulation which could cause adverse effects on the sensing head
----;;;0010228 -/--- Fo"m Fm" -~---- and the enclosure, A UNIQUE air flow monitor shall be included to
----- ---.-----"---.-.--.- ,--------- - --- --.-......--. . indicate the presence of air Ilow through the detector, Air duct detector
672200068 Round Duct Mounting Gasket shall comply with the requiremenls 01 UL268A without the attachment of
---"------ --_._----- any sampling inlet or exhaust tubers), Extension sampling tubes, where
66809084A Relay - 10 Amp required, shall be easily installed after the housing is mounted to the duct
Sentrol, Inc. by passing them through the duct detector enclosure,
t:5' Corporate Headquarters: Distributed By:
12345 SW Leveton Drive
Tualatin, OR 97062
A Product of Sentrol, Inc. 503-692-4052
Technical Support: 800-648-7424
Bulletin 2269,SS6 December 1994 U,S. and Can..da: 800-547-2556
L- Appearances and details subject to change without notice
609 Series Air Duct Smoke Detectors
Table 4: Contents of Pre-packaged Duct Detector Models
Pre-packaged Model Number
609U01
609U02
609U01,11
609U02-11
----
609U01-24
609U02-24
1---- 611 UD Photoelectronic
G09U24 1
609U24
----
611 UD Photoelectronic 609U31,
--- -,...---,- u____ _ --- -, -'--_______, __.... ..___...__,...1
Ji
_=::::J
609U01-31
609U02-31
612UD Ionization
612UD Ionization
609U31
1_ For electrical specifications of function cards, see Tables on previous pages,
Accessories
All function cards provide for remote alarm indicator and/or remote
test capability when used in conjunction with the ESL 606 Series
accesories: Model 606U1 Remote Alarm Indicator or Model 606U2
Remote Test and Alarm Indicator, All four-wire function cards
include an extra terminal to facilitate connection of a local or remote
detector alarm reset switch for use with the ESL Model 609URS
Reset Switch or Model 606U3 Remote Alarm Indicator with Remote
Test and Reset. See Table below for additional accessories,
-- -
Description
Remote Indicator
Remote Indicator with Keyed Remote Test
Remote Indicator with Keyed Remote Test
and Reset
Inlet Sampling Tube Extension-2 ft.
Inlet Sampling Tube Extension-4 ft.
--
Inlet Sampling Tube Extension-S ft.
Test Tool
Powel Supervision Unit 12 VDC systems
Power Supervision Unit 220 V AC systems
Local Reset Switch, N/C with 6" Leads
Replacement Parts
r __~~~el Number '-___ Descrlpt~on__,___J
620010228 Foam Filter]
~-------._------_.__._.__.- -----------------.-- .
672200068 Round Duct Mounting Gasket
66S090S4A
Relay - 10 Amp
Sentrol, Inc.
Corporate Headquarters:
12345 SW Leveton Drive
Tualatin, OR 97062
503-692-4052
Technical Suppa"': 800-648,7424
Bulletin 2269-8S6 December 1994 U.S. and Can..da: 800-547.2556
Appearances and details subject to change without notice,
t:5l:
A Product of Sentrol, Inc.
PRODUCT DATA
Dimensions:
Length: 16,5 in, (42 cm)
Width: 5,5 in, (14 cm)
Depth: 4,0 in, (10 cm)
Integral sampling tubes extend the width by 5,5 inches and require two
holes of 2 inches diameter for clearance
Weight: ,"
Maximum weight is 7S,75 oz, (2,23 kg,)
Operating Temperature Range:
0-50aC, 32-1200F
Operating Duct Air Velocity Range:
300-2000 fl./min, when the 612UD is installed within the duct hOllsing
300-4000 ft./min, when the 611 UD is installed within the duct housing
SPECIFICA TrONS
This Air Duct Detector shall be either an ESL Model 609U01 Photoelec-
tronic Detector, Enclosure assembly or an ESL Model609U02 Ionization
Detector, Enclosure assembly,
The base of the enclosure and the manifold shall be constructed of solid
structural foam, and shall incorporate an air-tight smoke chamber in
compliance with UL268A, Standard for Smoke Detectors for Duct Appli-
cations, The detector enclosure shall be equipped with an integral
mounting base capable of accomodating either a photelectronic or ioniza-
tion detector head and shall be capable of local testing via a magnetic
switch, The clear covers for the enclosure shall be constructed of Lexan,@
The detector shall operate at air velocities of aDO feet per minute to 2000
feet per minute utilizing a 612UD sensing head, and 300 - 4000 feet per.
minute utilizing a 611 UD sensing head, The duct detector shall be
capable of interfacing directly with ESL 606 Series Remote Stations.
which shall provide for local alarm indication and test functions, Local or
Remote Reset capability shall be provided for utilizing the Models
609URS or 606U3 respectively,
An integral filter system shall be included to reduce dust and residue
accumulation which could cause adverse effects on the sensing head
and the enclosure, A UNIOUE air flow monitor shall be included to
indicate the presence of air flow through the detector, Air duct detector
shall comply with the requirements of UL268A without the attachment of
any sampling inlet or exhaust tube(s), Extension sampling tubes, where
required, shall be easily installed after the housing is mounted to the duct
by passing them through the duct detector enclosure,
Distributed By:
:5
Table 2: Electrical Specifications - Four-Wire Function Card Application, Low Voltage AC or DC
Voltage 2 Amp 10 Amp 1 Amp Power-On
Model Ranje I Standby Alarm Alarm Alarm su~rvlso~ LED
Number Stan by Current Current Contact3 Contact 3 ontact . (green)
609U11 8.5-33 VDC 50 uA 48mA 1 Form A , - -
24 VAC 1 Form C
609U31 8.5-33 VDC 9mA 57 mA 1 Form A - - y
24 V AC 1 Form C
609U12 17-33 VDC 50 uA 59 mA 1 Form A 2 Form C - -
24 V AC (11 mAl' (48 mA)'
609U32 17-33 VDC 9mA 68mA 1 Form A 2 Form C - y
24 V AC (20mA)' (57 mAl 1
f--,
609U33 17-33 VDC 17 mA 65mA 1 Form A - 1 Form A Y
24 V AC 1 Form C
609U14 17-33 VDC 8mA 67 mA 1 Form A 2 Form C 1 Form A -
24 V AC (19 mAl' (56 mAl'
609U34 17-33 VDC 17 mA 76mA 1 Form A 2 Form C 1 Form A Y
24 V AC (28mA)' (65 mAl ,
1, The 10 Ampere contact relay of the 609U 12. 609U14. 609U32 and 609U34 function cards can be field programmed to be normally operated. and
to release on alarm. sensing head removal or power loss. by moving jumper J1 0 from pin P8 to pin Pl, If the relay is programmed in such a manner,
the standby current @24 VDCN AC is increased by 10 milliamperes, and the alarm current is reduced by 10 milliamperes, as shown in parenthesis,
2, The Form A supervisory contact is closed with power applied,
3, Relay contact rating shown are for a resistive load at 30 VDC or 120 VAC maximum,
Table 3: Electrical Specifications - Four-Wire Function Card Application, Line Voltage AC or Low Voltage AC or DC
Model Voltage Standby 2Amp 10 Amp 1 Amp
Ran9Je Alarm Alarm Alarm SU&ervlso~
Number Stan by Current Current Contact3 Contact3 ontact2.
609U21 102-132 VAC or 15 mA 20mA 1 Form A - -
17-33 VDC/24 VAC' I 1 Form C
609U22 102-132 VAC or 15 mA 20 mA 1 Form A 2 Form C -
17 -33 VDC/24 V AC 1
609U23 102-132 VAC or 15mA 20m A 1 Form A - 1 Form A
17 -33 VDC/24 V AC' 1 Form C
609U24 102-132 VAC or 15 mA 20 mA 1 Form A 2 Form C 1 Form A
17 -33 VDC/24 V AC'
609U25 187-242 VAC 5mA 10 mA 1 Form A 2 Form C -
1, For Models 609U21. 609U22. 609U23. and 609U24, when converted in the field for low voltage operation the electrical specifications of the simi/iar low
voltage card in Table 2 apply. For example, if you convert a Model609U21 for low vol/age operation use the specifications of a 609U31. For a convened
609U22. use the specifications of 609U32. etc,
2, The Form A supervisory contact is closed with power applied,
3, Relay contact ratings shown are for a resistive load at 30 VDC or 120 VAC maximum,
Sampling Tubes
A pressure differential pulls air in through the inlet sampling tube
and into the sampling chamber, then sends it back out into the duct
through the outlet sampling tube,
Each duct detector housing is equipped with 5,25 inch inlet and
exhaust sampling tubes, The ends of these tubes are cut at a
450angle, The inlet tube faces upstream and the exhaust tube
faces downstream to ensure airflow through the housing, The
tubes provide the means of obtaining a sample of air from the duct.
Although this product is approved for use without additional
extension sampling tubes, optional lubes may be required by the
authority having jurisdiction, OPTIONAL sampling tubes are
available in several lengths,
EQUIPMENT
The ESL 609 Series Air Duct Smoke Detector consists of three
primary elements: a) the sensing head, b) the selected function
card, and c) a housing for the detector and function card,
Duct Detector Housing
The base section of the housing that mounts to the duct wall
includes: a) integral inlet and exhaust sampling tubes, b) a
sensing head mounting base with an automatic-opening continu-
ity switch, c) a conduit connection plate with ground screw, d) the
detector cover/manifold monitor, and e) the function card com,
partment cover.
The 609U01 is an air duct detector enclosure supplied with a
611 UD photoelectronic smoke sensing head, The 609U02 is
supplied with a 612UD ionization smoke sensing head,
Electrical Function Cards
Any ofthe function cards may be used with the Models 609UO 1 and
609U02 duct detector assemblies, All function cards include a
local alarm (red) indicator, local test capability, and provision for
remote test and remote alarm indicator connections, All models
except 609U10 include a remote detector reset capability, All
models with auxiliary alarm contacts are Listed as suitable for
releasing service applications,
Two-Wire Applications
Three function cards are currently available for two,wire alarm
initiating use, Two-wire detectors must be connected to Listed
compatible initiating circuits. Two-wire function cards do not in-
clude a power-on LED (green), Electrical specifications are shown
in Table 1, below,
Tabte1: Electrical Specifications - Two-Wire Function Card Application, Low Voltage DC
:',., ~ "~ti;of-h:;":'i: ~~~p~'~:!!,..:! :"'~;~'. ,Vottage i : Voltage 'Alarm
:"M0d8I1' Compatibility Standby Alarm
. Ii' , Range ,: ,Range Current Contacts 1
'.,~~~bttr. ' f~b Identifier" ~ Current
_~. "~'l ~''''.~''~' ';' ;io~~f! ::;,', ),\,,.,,," Sta.ndby '!:!,Alarm ,
609U10 SOD 8,5-44 VDC 33 VDC max, 50 uA max, 60 mA max. None
609U1l 502 B.5-44 VDC 33 VDC max, 50 uA max, 60 mA max, lA, lC (2 Amp)
2
609U12 536 8,5-44 VDC 33 VDC max, 50 uA max, 70 mA max, 1A (2 Amp), 2C (10 Amp)
1, Relay contact ratings shown are for a resistive load at 30 VDC or 120 VAC maximum,
2, When the Model609U12 function card is used in a two-wire initiating circuit application. the 10 ampere relay must NOT be programmed
for normally operated releasing service, If the relay were to be programmed in this manner, the standby operating current would be
increased from 50 microamperes to 10 milliamperes,
Low Voltage, Four-Wire Applications
Seven function cards are currently available for low-voltage, four-
wire alarm initiating and releasing service use, or stand-alone
releasing service applications, All of the low voltage four-wire
function cards can be powered from a nominal 24 VAC source,
available in many HV AC applications, Electrical specifications
are shown in Table 2, on the following page,
Line or Low Voltage, Four-Wire Applications
Four function cards are currently available for line voltage (i,e"
120 V AC nominal), four-wire alarm operation, All four function
cards can be field modified for low voltage, four-wire opera-
tion by cutting Jumper J12 located In the upper right-hand
comer of the function card, below terminals 0 and 1. Four-
wire LinelLow voltage function cards INCLUDE a power-On LED
(green), Electrical specifications are shown in Table 3, on the
following page,
220/240 V AC Function Card
The Model609U25 function card is currently the only function card
available for 220/240 VAC, four-wire operation, Electrical speci-
fications are shown in Table 3, on the following page, .
Field Programming of the 10 Ampere Contacts for Releasing
Service.
As supplied, the two, 10 Ampere rated, Form C auxiliary contacts
provided with function cards 609U12, 609U14, 609U22, 609U24.
609U25, 609U32. and 609U34 transfer on alarm ONLY, The relay
that controls these contacts may be field programmed, by moving
jumper J10 from pin PB to P7, to be energized in the normal
standby condition, so that the contacts transfer on removal of the
sensing head, loss of power to the air duct detector assembly, or
alarm of the sensing head, This may be desirable in many
releasing service applications,
~~
,
609 SERIES
AIR DUCT SMOKE DETECTORS
DESCRIPTION
The ESL 609 Series Air Duct Smoke Detectors consist of an ESL 600
Series photoelectronic or ionization smoke detector head, a Model
609UOO duct detector housing, and one selected function card, The
interchangeable sensing head and function card configuration allows
great flexibilily in product application.
The assemblies feature a modular design that allows easy selection
of the desired signaling and control functions. The rugged mechani-
cal design includes a manifold and a clear partitioned cover that
directs all sampled air through the sensing chamber of the selected
smoke detector.
The clear partitioned cover allows viewing of the UNIQUE integral air
flow monitor which indicates the presence and direction of air flow
through the sensing area of the enclosure, Additionally, the cover
includes a probe port for in-place measurement of the actual air
velocity using an anomometer. The air inlet filter may be visually
inspected through the clear cover for dust and dirt accumulation,
A solid steel conduit mounting plate features knockouts for 1/2 and
3/4 inch conduit and provides continuous grounding between con-
duits, Integral inlet and exhaust sampling tubes, which are suitable
for duct widths of six or more inches, are provided, OPTIONAL
extension sampling tubes are available in two, four, and eight foot
lengths,
This product Is approved for use without additional extension
sampling tubes.
NOTE: In some applications, the addition of an optional extension
sampling tube may cause the air flow monitor to stop rotating, This
is a result of the lesser air volume being sampled with the optional
extension tube, mostly attributable to its smaller inside diameter,
Standard features also include a local red LED alarm indicator, local
functional test capability, and a continuity switch for checking the
system wiring,
The integral compartment accepts one electronic function card,
Each function card is provided with barrier.type, clamping-plate,
screw terminal strips to accept field wiring connections of wire sizes,
12 AWG through 18 AWG, These terminal strips are designed to
prevent "looping" of wires and provide for supervision of conductors,
Function cards are available in several configurations, Please refer
to pages 2 and 3 for electrical specifications,
APPROVALS
The ESL 609 Series Air Duct Smoke Detectors are for use in commer-
cial fire protective signaling systems, NFPA 71 and 72 (formerly
designated as 72A, 728, 72C and 720), and in commercial air
conditioning and ventilating systems (NFPA 90A), Listed by Under-
writers Laboratories, Inc,; California State Fire Marshal Approved
(Listing #3240-447:120); New York City, Board of Standards and
Appeals approved (Calendar No, 122-73-SA); State of Maryland
approved (Permit #1905); City of Cleveland approved (Docket S-5'88),
f:5l.
California State
Fire Marshal
Approved
Patented
'.", .
~:::---T~~'" 'A~
~ -~ ,.Ij,.l ,
---' :;,.'
FEATURES
@
· Photoelectronic or Ionization Detection
~, Requires NO Extension Sampling Tub~s
· UNIQUE Visible Air-Flow Indicator
· Two-wire 12/24 VDC Operation
· Four-wire 120 VAC, 24 VDC, 24 VAC Operation
· Modular Design
· Transparent Housing Covers
· Local Reset Capability
· Local Test and Alarm LED
· Remote Alarm, Test and Reset Capability
· Optional Auxiliary Alarm Contacts
· Optional Supervisory Contacts
· Listed to UL 268A
APPLICATION
The function of an air duct smoke detector is to detect smoke for the
primary purpose of controlling air movement by air conditioning and
ventilating systems, in an attempt to prevent panic and damage from
the distribution of smoke and gaseous products,
The interchangeable detector configuration allows great flexibility in
product application, The ESL 600 Series smoke detectors are suited
for commercial, industrial, institutional and residential fire alarm
systems,
Electronic function cards provide for two-wire and four-wire operation
for alarm initiation and/or releasing service applications, Two-wire
detectors must be connected to UL Listed compatible initiating cir-
cuits, Four-wire function cards forlow voltage DC operation, may also
be operated from a nominal 24 VAC power supply, commonly avail-
able in many HV AC applications, For more application information on
the 609 Series function cards, refer to pages 2 and 3,
ESL, Initiating Devices
,103, Series. ,.".""
Manual Fire Alarm Stations
l'
. Single and dual action pull stations
· Terminal or pigtail connections
· Semi-flush or surface mounting
Listings
· CSFM approved
· UL approved
NYC BSA approved (103-22, l03,22S
and 103-24)
~
LlSTEO
103-20
103,21
103-22
103-22S
103-23
103-24
103-31
103-32
103-42
103-60
103-80
Accessories
103-25
103-26
Single action (SPST) with hex reset
Single action (DPST) with hex reset
Dual action (SPST) with hex reset
Dual action (SPST) with hex reset and NY stripe
Dual action (DPST) with hex reset
Dual action, pre-signal (DPST) with hex reset
Single action (SPST) with key reset
Single action (DPST) with key reset
Dual action (SPST) with key reset
Weatherproof, single action (SPST) with key reset
Explosion-proof, dual action (DPDT) with key reset
Red,.surface back box for 103-20 through 103-42
Replacement glass rod for 103-20 through 103-60
104 Series ' , , , , , . ,
Heat Detectors
I~~;'-'
l ~.~,
. .'
~'~
.j-
. , '
Listings
. CSFM approvcd
. LlL52J
Ncw York, Board of Standards and
Appeals approved
. Complies with NFI',\ 72
~
USltO
....J
104-13
104,14
104- 1 5
104,16
c::
u.:
~
1.800.547,2556 SENTROL. INC
600 SERIES ACCESSORIES
DIMENSIONS-ALL MODELS (Model 606U3 shown)
4,112"
SCHEMATIC DRAWINGS
820 ohms
04
05
Model 606U7
t:5l
Front View
I 2-3/4" 'I
1\ (G /~
d
-
o . " 0 . 0
0
NORMAL
~::::
820 ohms
Model 606U2
SENTROL, INC.
10831 SW Cascade Blvd,
Portland, OR 97223
Sales: 800-547-2556
Fax: 503-684-9230
Technical Support: 800-648,7424
bulletin 2270-$4 September 1992
A::>pearances and details subject to change without notice,
3-9/32"
04
05
06
Distributed by:
Side View
~1-3/8"
o~
,~
test
Model 606U3
820 ohms
600 SERIES
ACCESSORIES
DESCRIPTION
The 606 Series remote indicators are designed for use
with the ESL 600 Series area fire detectors and the ESL
609 Series air duct-type smoke detectors, Model 606U1
is a remote indicator only, Model 606U2 features remote
indicator and key operated test switch, Model 606U3
features remote indicator and key operated test and
reset switch, A single key (Hudson Cat. 30) is supplied,
The terminal numbers on the remote indicators match
terminal numbers on ESL 600 Series area fire detectors
and 609 Series air duct-type detectors. Combination tri-
wall barriers and captive wire clamping plates ensure
secure wiring connections,
All models are constructed of high-impact thermoplastic,
Their decorative design and multi-colored labels make
the 606 Series attractive accessories,
APPLlCA TION
)
ESL 606 Series remote indicators are ideal for use in
applications where ESL 600 Series fire or air duct-type
detectors are not readily visible or accessible (i.e.,
installed in plenums, above suspended ceilings, below
raised floors), Model 606U3 is primarily used to provide
reset for detectors that are ul:/ed for releasing service,
and that are not connected to a fire alarm control unit.
INSTALLATION
The 606 Series mount to a standard single-gang
electrical switch box with a minimum depth of 1-3/8
inches (3.43 cm), Mounting screws are supplied. All
wiring connections must be made to the remote indicator
before mounting it to the switch box,
APPROV ALS
Listed by Underwriters Laboratories, Inc.; California
State Fire Marshal approved (Listing #7300-447:118),
REMOTE INDICATORS
MODEL
DESCRIPTION
606U1
Remote indicator
}
606U2
Remote indicator with test
606U3
Remote indicator with test and reset
t'
R-, "~," IndlCltlO'
,:~ .
--a
.....-
~'-
..
<8>
-.
Call1ornia State
Fire Marshal
Approved
FEATURES
h
t:5l
Remote Indicators
I#-~
@
· Remote alarm indication
· Optional remote TEST and RESET functions
· Easy wiring connections to ESL 600 Series
area and duct-type detectors
· Fits standard single-gang electrical boxes
· Wire clamp-type terminals
· Keyed alike to ESL control units and ESL
pull stations
· High-impact thermoplastic
· Attractive design
PRODUCT DATA
Height:
Width:
Depth:
Distance between screw holes
(center to center):
Indicator rating:
Switch rating:
Single key supplied,
4-1/2 in, (11,25 em)
2-3/4 in, ( 6,88 cm)
1-3/8 in, ( 3.43 em)
3-9/32 in, (8,20 cm)
6 VDC, 5 mA
4 A, 125 VAC
ESl 429 Series Smoke Detectors
Architectural and Engineering Specifications
The ESL 429 Series low-profile, self-diagnostic, two-wire smoke
detectors work on the light scattering principle, A pulsed
infrared light-emitting diode seNes as the light source, and a
high-speed photo-diode as the sensing element. When the
amount of light reflected onto the photodiode reaches the
SenSItiVIty setting, the smoke sampling rate increases, Three
(3) successive smoke sensings above the sensitivity setting are
required to sound an alarm, This design has superior
protection against false alarms caused by dust, insects, RF and
ambient-light
A confirmed alarm causes the normally flashing power
indicator LED to light continuously and the optional alarm
relay (available in "R" models) to operate, A trouble indication
is automatically displayed by flashing the LED every second,
This meets NFPA 72 field sensitivity testing requirements, An
internal 85 dB horn (available in "S" models) emits a steady
tone when the detector alarms and a pulsed tone when
power polarity is reversed, Also available is the "SS" model
which chirps when the unit goes outside the approved
sensitivity range for more than one day. Resetting the detector
will silence chirp for one day. until unit is restored to proper
sensitivity,
Product Data
Sensitivity ..,... ........ ,..............,........,.., max ..... 3,1 - l,OO/O/ft,
min.., 3, J + O,500/0/ft,
Operating temperature range ....,.......,..,......, 320F to J 200F
OOC to 500C
Operating humidity range ...............,....,.,....,... 0 to 95% RH
Minimum voltage -,C, CT, CRT, CST, CSST '..,.,......,...,... 8,5 \I
-N,.",,""""."".".'""""""""""",." 6,5\1
Maximum VOltage - C, CT, CRT, CST, CSST ..,......,.,........ 33 \I
- AT ................,.,...........,......,......,..,.... 20 \I
Maximum ripple (peak to peak) ........,..,..........,.......,..,.. J 0%
Typical average standby current ....,......,..,...,....,......,.. 70 IlA
Field wiring size..,.......,.......,.,....,.,................... 14 - 24 AWG
Selection Guide
The proprietary optical sensing chamber is field replaceable,
allOWing quick and easy cleaning and maintenance,
Models with auxiliary relays are approved for releasing seNice,
The very Jaw profile 429 Series detectors are equipped with a
hinged cover, a concealed tamper-resistant latch, and insect
screens,
All winng terminates in plug-in, clamp-type screw terminals,
The detectors mount to a standard single-gang electrical box,
a four-InCh octagonal, four-InCh square electrical box, or
WIREMOLD No, 5739 fixture box,
Smoke Detector Spacing
On smooth ceilings (as defined in NFPA 72), spacing of 30
feet (9, I meters) may be used as a guide, Other spacing may
be used depending on ceiling height, high air movement.
and other conditions or response requirements,
. ~
'''"'~''=I\= =) ""'j'=IW
Alarm current ..., draws max of 60 mA if not limited by panel
Max, avg, polarity reverse current - CST ........,......,...... J 0 mA
Sounder specifications ....,.......,..,.......,.......... 85 dB at 10ft,
Heat detector specifications
fixed temp, ..........,........,...... 1350F:t 50F (57,20C:t 2,80C)
rate of rise ... J 50F/min, & > 1050,:: (8.30C/min, & > 40,60C)
Relay specifications ..'..............,.., 2A @ 28 \I DC or 120 \I AC
Packaging ..,.,..........,..... 10 detectors are packed in a carton
Color ...............,.................,......,....., white cover/white base
with U\I inhibitor to prevent yellowing
2-wire compatibility ..,.....,........... see ESL Compatibility Index
Listings ......,.,.., UL 268, FM. CSFM and MEA (New York City)
for Canadian ULC listed products use 428 series
Designator Feature Description
Isolated Fixed Temp, Isolated fixed 1350F (570G) and rate of rise heat detector, independently trips the LED and alarm
H and Rate of Rise Heat relay output. Smoke detector activates internal sounder (local alarm) and auxiliary relay, but
Detector does not latch, Approved as both single station smoke alarm and system heat detector, Ideal for
hotel, motel and dormitory rooms where smoking is allowed.
R Auxiliary Relay Used to activate other devices such as elevator recall, door holders, strobes, etc, Listed for
releasing service, .
-
5 Built-in Sounder 85db built-in sounder alarms when smoke is detected or when power wiring polarity is reversed,
Built-in Sounder with 85db built-in sounder alarms when smoke is detected or when power wiring polarity is reversed,
55 Sensitivity Status Also, chirps when unit goes outside the approved sensitivity range for more than one day,
Output Resetting detector will silence chirp for one day, until unit is restored to proper sensitivity,
Integrated Fixed Integrated fixed 1350F (57oe) temperature and rate of rise heat detector offers double protection,
T Temp, and Rate of Either heat detector or smoke detector can trip and latch LED and alarm relay outputs.
Rise Heat Detector
CORPORATE H EADQUARTEJI.S
] 2345 SW LevelOn Dr.
Tualalin, OR 97062
Tel.: 503,692,4052
Fax: 503,691.7500
U,S, &: Canada: 800,547,2556
Technical Service: 800,648,7424
ESLN
A PRODUCT OF SENTROL, INC
Semrol. Ine, reserves the righl
10 change specifications
wilhoUl nOliee,
(1)] 995 Semrol. Ine.
[,IKK3,OJ"5-H,GIW
-E.
S"
L
N
PRODUCT
~,
-'
N FOR MAT
-)
· Intelligent, self-diagnostics
· Field replaceable optical chamber
· Low-profile design
· Plug-in terminal block
· Advanced false alarm immunity
)
o N
B U L LET
429 SERIES
Self-Diagnostic,
Two-Wire,
Photoelectric
Smoke Detectors
Model numbers: 429AT, 429C, 429CT,
429CRT, 429CST, and 429CSST
~ <8>
APPROIIED
California State Fire Marshal Approved
MEA (New York City)
The ESL 429 Series self-diagnostic, two-wire
smoke detectors continually monitor their own
sensitivity and operational status, and provide a visual
trouble indication if they drift out of sensitivity range
or fail internal diagnostics, This meets NFPA 72 fjeld
sensitivity testing requirements without the need for
external meters,
Additional diagnostic information is activated by
applying a magnet near the detector's integral reed
switch, This initiates a self-diagnostic routine and
provides visual indication of sensitiVity level, or if service
is required,
The 429 Series is easily cleaned by simply replacing .
ESL's proprietary field-replaceable optical chamber, All ..
models are designed to reduce false alarms from dust.
insects, RFI and external light.
An integral combination rate-of-rise and fixed J 3soF
(SrC), 50-foot rated, heat sensor is available with all "TOO
model detectors (see selection gUide), An integrated
silicon heat sensor and a dedicated microprocessor are
used to detect heat and perform the rate of rise calcula-
tions, for earlier heat detection,
continued
GENTEX
Architect & Engineering Specifications
The audible or audible/visual signal shall be Gentex model HG
or SHG or approved equal, and shall be listed by Underwriters
Laboratories per UL464 , and when combined with the strobe
option the strobe shall be listed per UL 1971. The notification
appliance shall also be listed with the Califomia State Fire Marshal
(CSFM) and the Bureau of Standards and Appeals (NYC).
The notification appliance shall produce a peak sound output of
90dBA or greater as measured in an anechoic chamber.
The maximum current consumption at 24VDC for the audible
only shall not exceed 17 milliamps and the maximum current
consumption forthe combination audible/visual notification appli-
ance when utilizing a 15cd strobe shall not exceed 95mA at
24VDC,
For those applications requiring the higher output in light
intensity, the maximum current consumption at 24 VDC shall not
exceed the combined current consumption of audible with the
following visual with each candela: 15/75cd shall not exceed 122
milliamps, 30/75 shall not exceed 160 milliamps. 11 Ocd shall not
exceed 237 milliamps,
The visual signal shall have a flash rate of 1 Hz regardless of
input voltage,
The notification appliance shall be provided with screw termi-
nals for in and out field wiring and the strobe shall be capable of
operating independently after the audible has been silenced,
The notification appliance shall be capable of mounting to a 4"
square back box and a 2 gang switch box of a minimum of 21/8"
M t' , 4" S b /b k t 21L" d ' , in depth, I
oun lng, quare oxes w rac e s /6 eep minimum 24 units per carton
4" square metal/non-metallic switch/outlet boxes 2'1e" deep minimum 11 pounds per carton HG
Gangable 2 gang switch/masonry outlet boxes 2'1e" deep minimum 116 pounds per carton SHG
Wiring Diagrams
~ HG HQ;l~ AND sn:; SERIES POWERED IN PARALLEL
SERIES
Dimensions:
~
~ EDLR
E SHG S<MIES WITH HORN AND STROBE POwERED INOEPENO<NTLY
NDU REMOVE ORCUIT COVER HOUSING AND REMOVE JUMPERS' AND 2
RE"LACE COVER AND PROCEED TO WIRE HORN INTO CIRCUIT
~ci~~~
F-A~'E..
S~~VISEO
~~~
\ .
\ '
EDLR
NOTE: POWER IS SUPPL!OD TO DEVICES WHEN CONTROL PANEL IS LATCHED.
~
, '.
NOTE: Supplied with beauty plugs to accommodate a variety of installations,
GENTEX
CORPORATION
Fire Protection Products: 10985 Chicago Dr,
Box 310, Zeeland, MI 49464
616/392-7195, FAX: 616/392-4219
n
t.." Printed on Recycled Paper
GX120491'16
'-
.GENTEX
)
4" Electronic Horn HG or SHG Series
Applications
4" low frequency electronic horn and
horn/strobe that meets code requirements
for supervised fire alarm systems for the
hearing impaired and ADA.
The HG/SHG series are quality elec-
tronic signaling appliances that offer you
both dependable evacuation signals and
visual alarms or a combination of both by
simple terminal wiring, The SHG series
can also be wired to have independent
operation of both horn and strobes. (See
wiring diagrams). This can be simply
done by removing two jumper plugs locat-
ed on circuit board, (See installation
manual for details.)
The HG/SHG series are easily field
changeable from a steady low frequency
alarm signal to a pulsing low frequency
alarm signal by simply removing a jumper
plug, Changing from steady tone to puls-
ing tone does not prevent reverting back
to original tone at a later date, All units are
shipped from the factory in the steady
alarm mode.
The HG/SHG series are designed to
be used for both new construction or
retrofit projects by easily mounting to 4"
electrical boxes or 2 gang old work boxes
(see back for details),
All HG/SHG appliances are UL 464/
1971 listed for use with fire protective
systems and are warranted for 2 years
from the date of purchase,
SERIES
SHG
Approvals
HG
@
(I\BVIA)
MEMBEFl
. Americans with Disabilities Act (ADA)
. BFP
. BSAlMEA #412-91-E
. CSFM #7135-569:115
. NFPA 72
. UL 464
Standard Features
; . Low frequency output.
. · Low current consumption 17mA @
nominal voltage, (HG124)
. Wide voltage range,
. Screw terminals, separate in/out wiring
option for both hom and strobe.
. Steady or pulsing tone,
Available Models
. Textured finish high impact plastic
faceplate,
. Wide variety of mounting options for new
construction and retrofit applications,
· Supplied with beauty plugs to accom-
modate a variety of installations.
. Xenon Strobe maintains constant flash
rate (1 per sec,) regardless of input
voltage,
. Flush or semi-flush mounting without
the need of a trim plate,
. 15/75 and 30/75 candela strobe op-
tion, Meets ADA 4,28.3 requirements,
· AII11 Ocd models exceed requirements
of 4,28,3 of the ADA.
. UL 464/UL 1971 listed for fire protective
service/signal for hearing impaired,
Combined Rated
Current
Light Effective @ Nominal
Model Operating Flash Intensity In Operating
Number Voltage Rates/Min Candela Voltage
HG124 10-30 17mA
;t' .;".".~~. :$,,, -..., :ii;
SHG12-15-1 10-16 60 15 130mA
SHG12-15/75 10-16 60 15 (UL 1971) 252mA
75 (UL 1638)
Combined Rated
Current
@ Maximum
Operating
Voltage
21mA
dB @10 Ft.
100
. '_?~-;~~~,; :~t~':{;o1!rx~.~::A;2;~~~;~~
102mA 90
173mA 90
~~~-:::jv~~
90mA 95
108mA 95
135mA 95
121mA 95
200mA 95
.._1_ :. ~~~';-..~:...: -~",.:,;.~f~':".:;~~r~:8F~':'~~'(:7~;.;-:'~~~:c~~~-:r~~
SHG24-15-1 21-30 60 15 95mA
SHG24-15/75-W 21-30 60 15 (UL 1971) 122mA
75 (UL 1638)
SHG24-30/75-W I 21-30 60 30 (UL 1971) 159mA
75 (UL 1638)
SHG24-15/75-C I 21-30 60 15 (UL 1971) 137mA
75 (UL 1638)
SHG24-110-1 I 21'30 60 110 237mA
Note: 24VDC 15 candela units have a start,up current of 114mA at 1 flash per second,
\. 15/75 candela units have a start-up current of 130mA (wall)
i 15/75 candela units have a start-up current of 140mA (ceiling)
k 30/75 candela units have a start'up current of 120mA
~.- 110 candela units have a start-up current of 148mA
WHEN PLACING AN ORDER: add the following to the end of the model number:
'W' Wall mount and 'R" = Red faceplate
'P' Plain (no lettering) 'W"= Off-White faceplate
'C' = Ceiling mount (1575 models only)
~:;
p-
I MADE IN THE
I U.S.A.
cont~ol to go into trouble, These conditions will restore
when battery voltage returns to 22 VDC or higher.
SIGNAL CIRCUIT TROUBLES, The 5295 has four
Style W (Class B) signal circuits, The signal circuits
are supervised against opens or shorts and will con-
tinue to operate normally during ground fault condi-
tions. When the movable shunt block is in the single
input position, a trouble condition detected on any of
the four signal circuits will cause the Signal 1 input
loop to open, causing the local control to go into trou-
ble, When the movable shunt block is in the dual input
position, a trouble condition detected on signal cir-
CUits 1 or 2 will cause the Signal 1 input to open, A
trouble condition on signal circuits 3 or 4 will cause
the Signal 2 input to open, When the signal circuit
trouble condition is corrected, the appropriate Signal
loop input will restore to normal.
SPECIFICATIONS
ELECTRICAL SPECIFICATIONS
· AC Input: 120 V AC at 2 amps
· Output: 24 VDC at 6 amps
· Built-in battery charger for 2 to 12 volt 6.5 amp
hour batteries will provide 24 hour standby with 15
minutes in alarm
· Low AC: 102 V AC for 6 or more hours
· Restore Low AC: 108 V AC
· Low Battery: 20,4 VDC
· Low Batt Restore: 22 VDC
. Signa! 1 & 2 inputs: 9 to 32 VDC
· Signal circuits: 20,3 to 27.3 VDC at 1.5 amps each,
4,7 K ohm EOl resistor required on each circuit
INDICATOR LIGHTS
· AC Power On - Green
· Battery Trouble - Yellow
· Signal 1 Trouble - Yellow
· Signal 2 Trouble - Yellow
· Signal 3 Trouble - Yellow
· Signal 4 Trouble - Yellow
MECHANICAL SPECIFICATIONS
· Dimensions: 12-1/4 inches W x 16 inches H x
3 inches D
(31,1 cm W x 40,6 cm H x 7.6 cm D)
· Shipping Weight: 8 Ibs, 14 OZ, (4 kg.)
· Color: Red
APPROVALS
· UL Listed - UL864
· NFPA -72A
· California State Fire Marshal approval pending
· NYC MEA (BSA) approval pending
· Other approvals pending
LIGHTNING PROTECTION: Silent Knight guarantees this product against lightning strikes! We will repair or
replace the Silent Knight equipment, if necessary, should lightning disable it during the one-year warranty period, It's
just another reason why Silent Knight has been a nationwide leader in electronic security for 25 years,
~ SILENT
~ ~~~~~
7550 Meridian Circle, Maple Grove, MN 55369-4927
1-800-446-6444 or in Minnesota (612) 493-6435
Fax: (612) 493-6475
THE QUALITY EDGE
MADE IN
AMERICA
Form No, 150781 (3/93)
)
, ,
~,SILENT
~ ~~:~
FIRE ALARM
ACCESSORY
fH,' Me. j'~,29r:
~17 '~""",~ i ,,; "
Signal Power Expander
FEATURES
· Adds More Signal Power to Local Fire
Controls
· Aids Compliance with ADA Require-
ments Using Existing Local Control'
· UL Listed for Alarm Signal Circuits
· Two Supervised Inputs
· Four Style W (Class B) Signal Circuits
· Highly Efficient Switching Power Supply
(24 VDC at 6 Amps)
· 1 0 to 30 Volt Activation
· Fuseless Design
} · Compatible With Most Manufacturers'
-"'- Local Controls
The Model 5295 Signal Power Expander provides
additional supervised circuit capacity for local fire
alarm systems. This makes the Model 5295 a very
cost-effective solution to meeting tough Americans
with Disabilities Act (ADA) requirements, The 5295
increases the signaling power available for the addi-
tional sounders and the brighter strobes called for by
the ADA. Meeting those requirements is easily
accomplished in a retrofit or new installation,
DESCRIPTION
The 5295 is a 24 volt 6 amp switching type power
supply housed in its own red cabinet. It contains an
integral precision battery charger capable of charg-
ing two 12 volt 6.5 amp hour batteries, The cabinet
provides ample room for field wiring and standby
batteries,
~,
,3'
CONNECTION TO LOCAL FIRE
CONTROL
The 5295 can be connected to a local fire control
which utilizes polarity reversing Style W (Class B)
type signal circuits operating between 9 and 32 volts
DC. The local control signal circuit is connected to
one of the inputs on the 5295, The local control's
signal circuit end-of-line resistor is also connected
across two terminals on the 5295, which provides
supervision between the 5295 and local fire control.
Polarized audible and/or visual indicating devices
are then connected to the 5295 signal circuits using
the 4.7K ohm end-of-line resistors provided, A mov-
able shunt block allows selecting whether all four
signal circuits on the 5295, are activated by a single
input from the local control, or whether each input
activates two signal circuits, Since the 5295 draws
very little power from the local control, it is possible
to connect one 5295 to each signal circuit, on the
local control, and still provide full supervision of the
signal circuits all the way back to the local control. .
SUPERVISION
LOW AC, When a Low AC condition (102 VAC or
less) is detected, the green AC POWER indicator
will turn off, If Low AC is detected for longer than 6
hours, the 5295 will open the Signal 1 and Signal 2
input loops, causing the local control to go into trou-
ble, These conditions will restore when AC returns
to 108 V AC or higher,
LOW BATTERY, When a Low Battery condition,
20.4 VDC or less, is detected, the yellow BATTERY
indicator will turn on and the 5295 will open the
Signal 1 and Signal 2 input loops causing the local
FIRE ALARM SYSTEM EQUIPMENT SUBMITTAL
Item !. Q.!y
A 1
B 10
C ...,
..:.
D ",,:.
..:..
D-1 ...,
..:..
D-2 "":'
..:..
E 4
NOTE: ( 1 )
Style !.
Description
5295
Signal Power Expander
MountinQ
PaQe !.
SHG24-15/75-W ADA Horn & Strobe
Surface
1
4" Square
2
429C
Photoelectric Smoke Det. 4" Square
-::-
....,
609U01-11
606U2
205B
Photoelectric Duct Det.
Remote indicator & test
3 FT. Sampling Tubes
To Duct
l-ga ng
To HSG.
4,5
4,5,6
4,5
103-31
Manual Pull Station
1-Gang
7
The signal power expander item A will provide 2 additional signal
circuits to support the new ADA horn & strobe lights as well as two
spare circuits for future expansion.
(2) The manual pull stations item E will be keyed identical to existing
manual pull st~tions.
(3) All submitted equipment is UL cross listed, where necessary, to the
existing Simplex 4002 system.
.
r ~\. SECURITY ENGINeeRS SYSTSMS, INC,
Jh~ TAMPA BAY OFFICE
L '180 Scarlet Blvd.
Oldsmar, FL 34677
FL uc.. -EFOOOCl32'
SYSTEM DESIGN &. ENGINEERING
FIRE ALARM . SECURITY . CARD ACCESS
C.C.T.V. . SOUND' VIDEO IMAGING
SYSTEM INSTALLATIONS &. SERVICE
[813) 854-2078 - FAX [813) 855-2505
.ALL INFORMATION MUST BE COMPLETE TO PROCESS MATERIALS AND SETUP JOB!!
Job Maintenance Form
Job Number I Q 11( .
(To be assigned by- home office)
Job Type /' **Turnkey
Material Sale
Job Name EAs'T PASCoe YM(^ Add'I';1l1\A:
Job Address 3TVCJ ~.e.t9<',;' f2.d
Orig. Sale Price $ ~S I~-
**Tax Inc (Turnkey & Small Service)
Sales Person M \'LE ~cro \\JAi\
ESTIMATES \
(1) Labor hours '0 . x $15.00=sqoo -
O.T. Labor hours x . =
(2) Labor Hrs. Eng. t; x $20.00= .. 10 C>
(2) Labor Hrs. P.M. 5 x $20.00= A 100
Material Cost. .. g"15-
(3) Tax (Turnkey & Small Service Sales)
Wire Cost :8 '2-&./:0-
Mise/Other Cost
Subcontractor
Sub Name
Shipping Cost If 50 -
Total Cost $ '14"5-
/
Date: 3u..ne. "LI. (qq ~
-
**Billable Service
1\10'" - 7A"'~I...)
.:It '00-
~y,"-d:.
-
~
SHIPPING
::stimated Ship Date: ASAP
Ship To Job Site
Ship To Contractor Office
./ Hold For Turnkey Job
Other
Revised 08-01-94
Material and Checkout(1)
**Small Service Install
City and Zip ~a p'rv.{r' bJ~ f Ft... 33~4.0
Plus Tax
Service Person
BILLING d bSq
Bill To Cl~ of .~~S'
Address 23~ >' I~ ~
City '2.e p ~ If h -lis
State ~L Zip 335-to
Phone ( )
Contact Name Shl" l~ DD P-.D
Draw Date
uNeed Certified Pavroll?
uYes UNo v
**If yes, Attach copy of
wage decisions
P.O. # 224-1"
If new account credit info must be attached before
Job set up
(1) For material and checkout orders:
Sales less than S75,000, labor cost must be
greater than 12.5%. Sales greater than $75,000,
labor cost must be greater than 7.5%
(2) Include hours for Engineering , Drafting, Project
Managing.
(3) Turnkey only tax on our cost of material and wire.
*'" Job Type - if job is turnkey and small service
sales, then it must be quoted tax included. If job is
materials and checkout, it must be quoted plus
tax.
OVER
BRANCH OFFICE
07111 GRAND NATIONAL DR. *' 101-A ORLANDO. FL 32819 (407) 352-4752 FAX 352-0023
-..--------....
- .____..__u__u_
SYSTEM TYPES(S)
(CHECK ALL APPLY)
/
Fire Alarm
Sound!1 ntercom
Other
Card Access
Burglary
Door Security
CCTV
Drawings
Scope Of Work
E')(ttv\c1 by~..;tZv"J S'l~f~ !.f OO! ~1-r1;;:,. Wh\c:~ h~ y. SfQ..J
....,
;...~~
Special tools or shop material needed before start
FIRE ALARM SYSTEM EQUIPMENT SUBMITTAL
Item !. Q.!y
A 1
B 10
C ...,
..:..
D "":'
..:..
D-1 2
D-2 "":'
..:..
E 4
NOTE: ( 1 )
Style !.
Description
5295
Signal Power Expander
MountinQ
Paoe !.
SHG24-15/75-W
ADA Horn & Strobe
Surface
1
429C
Photoelectric Smoke Det.
4" Squa re
2
609U01-11
606U2
205B
Photoelectric Duct Det.
Remote indicator & test
3 FT. Sampling Tubes
4" Square
3
103-31
Manual Pull Station
To Duct
1-ga ng
To HSG.
4,5
4,5,6
4,5
1-Gang
7
The signal power expander item A will provide 2 additional signal
circuits to support the new ADA horn & strobe lights as well as two
spare circuits for future expansion.
(2) The manual pull stations item E will be keyed identical to existing
manual pull st~tions.
(3) All submitted equipment is UL cross listed, where necessary, to the
existing Simplex 4002 system.
t
)
a
RRE SYSTEMS,.
FIRE ALARM
ACCESSORY
Model 5295
Signal Power Expander .
.~.
;~.
.:.:7
SILENT
KNIGHT
FEATURES
.l
· Adds More Signal Power to Local Fire
Controls
· Aids Compliance with ADA Require-
ments Using Existing Local Control'
· UL Listed for Alarm Signal Circuits
· Two Supervised Inputs
· Four Style W (Class B) Signal Circuits
· Highly Efficient Switching Power Supply
(24 VDC at 6 Amps)
· 1 0 to 30 Volt Activation
· Fuseless Design
· Compatible With Most Manufacturers'
Local Controls
The Model 5295 Signal Power Expander provides
additional supervised circuit capacity for local fire
alarm systems. This makes the Model 5295 a very
cost-effective solution to meeting tough Americans
with Disabilities Act (ADA) requirements. The 5295
increases the signaling power available for the addi-
tional sounders and the brighter strobes called for by
the ADA. Meeting those requirements is easily
accomplished in a retrofit or new installation.
DESCRIPTION
The 5295 is a 24 volt 6 amp switching type power
supply housed in its own red cabinet. It contains an
integral precision battery charger capable ot charg-
ing two 12 volt 6.5 amp hour batteries. The cabinet
provides ample room tor field wiring and standby
batteries.
CONNECTION TO LOCAL FIRE
CONTROL
The 5295 can be connected to a local tire control
which utilizes polarity reversing Style W (Class B)
type signal circuits operating between 9 and 32 volts
DC. The local control signal circuit is connected to
one ot the inputs on the 5295. The local control's
signal circuit end-ot-line resistor is also connected
across two terminals on the 5295, which provides
supervision between the 5295 and local fire control.
Polarized audible and/or visual indicating devices
are then connected to the 5295 signal circuits using
. the 4.7K ohm end-ot-line resistors provided. A mov-
able shunt block allows selecting whether all four
signal circuits on the 5295, are activated by a single
input from the local control, or whether each input
activates two signal circuits. Since the 5295 draws
very little power trom the local control, it is possible
to connect one 5295 to each signal circuit, on the
local control, and still provide full supervision ot the
signal circuits all the way back to the local control. .
SUPERVISION
LOW AC. When a Low AC condition (102 V AC or
less) is detected, the green AC POWER indicator
will turn off. It Low AC is detected tor longer than 6
hours, the 5295 will open the Signal 1 and Signal 2
input loops, causing the local control to go into trou-
ble. These conditions will restore when AC returns
to 108 V AC or higher.
LOW BATTERY. When a Low Battery condition,
20.4 VDC or less, is detected, the yellow BATTERY
indicator will turn on and the 5295 will open the
Signal 1 and Signal 2 input loops causing the local
control to gC3.into trouble. These conditions will restore
when battery voltage returns to 22 VDC or higher.
SIGNAL CIRCUIT TROUBLES. The 5295 has four
Style W (Class B) signal circuits. The signal circuits
are supervised against opens or shorts and will con-
tinue to operate normally during ground fault condi-
tions. When the movable shunt block is in the single
input position, a trouble condition detected on any of
the four signal circuits will cause the Signal 1 input
loop to open, causing the local control to go into trou-
ble. When the movable shunt block is in the dual input
position, a trouble condition detected on signal cir-
cuits 1 or 2 will cause the Signal 1 input to open. A
trouble condition on signal circuits 3 or 4 will cause
the Signal 2 input to open, When the signal circuit
trouble condition is corrected, the appropriate Signal
loop input will restore to normal.
SPECIFICATIONS
ELECTRICAL SPECIFICATIONS
· AC Input: 120 V AC at 2 amps
· Output: 24 VDC at 6 amps
· Built-in battery charger for 2 to 12 volt 6.5 amp
hour batteries will provide 24 hour standby with 15
minutes in alarm
· Low AC: 102 V AC for 6 or more hours
· Restore Low AC: 108 V AC
-:;
. Low Battery: 20.4 VDC
Low Batt Restore: 22 VDC
· Signal 1 & 2 inputs: 9 to 32 VDC
. Signal circuits: 20.3 to 27.3 VDC at 1.5 amps each,
4.7 K ohm EOL resistor required on each circuit
INDICATOR LIGHTS
· AC Power On - Green
· Battery Trouble - Yellow
· Signal 1 Trouble - Yellow
· Signal 2 Trouble - Yellow
· Signal 3 TrOUble - Yellow
· Signal 4 Trouble - Yellow
MECHANICAL SPECIFICATIONS
· Dimensions: 12-1/4 inches W x 16 inches H x
3 inches D
(31.1 cm W x 40.6 cm H x 7.6 cm D)
. Shipping Weight: 8 Ibs. 14 oz. (4 kg.)
· Color: Red
APPROVALS
· UL Listed - UL864
· NFPA - 72A
· California State Fire Marshal approval pending
· NYC MEA (BSA) approval pending
. Other approvals pending
LIGHTNING PROTECTION: Silent Knight guarantees this product against lightning strikes! We will repair or
replace the Silent Knight equipment, if necessary, should lightning disable it during the one-year warranty period. It's
just another reason why Silent Knight has been a nationwide leader in electronic security for 25 years.
~ SILENT
~ ~~~~~
7550 Meridian Circle, Maple Grove, MN 55369-4927
1-800-446-6444 or in Minnesota (612) 493.6435
Fax: (612) 493-6475
THE QUALITY EDGE
MADE IN
AMERICA
Form No. 150781 (3/93)
z
GENTEX
.I
4" Electronic Horn HG or SHG Series
Applications
4" low frequency electronic horn and
horn/strobe that meets code requirements
for supervised fire alarm systems for the
hearing impaired and ADA.
The HG/SHG series are quality elec-
tronic signaling appliances that offer you
both dependable evacuation signals and
visual alarms or a combination of both by
simple terminal wiring. The SHG series
can also be wired to have independent
operation of both horn and strobes. (See
wiring diagrams). This can be simply
done by removing two jumper plugs locat-
ed on circuit board. (See installation
manual for details.)
The HG/SHG series are easily field
changeable from a steady low frequency
alarm signal to a pulsing low frequency
alarm signal by simply removing ajumper
plug. Changing from steady tone to puls-
ing tone does not prevent reverting back
to original tone at a later date. All units are
shipped from the factory in the steady
alarm mode.
The HG/SHG series are designed to
be used for both new construction or
retrofit projects by easily mounting to 4"
electrical boxes or 2 gang old work boxes
(see back for details).
All HG/SHG appliances are UL 464/
1971 listed for use with fire protective
systems and are warranted for 2 years
from the date of purchase.
SERIES
- \ l~iFlu.
I . ..
R
E ~
SHG
Approvals
HG
@
MEMBER
(NMA)
· Americans with Disabilities Act (ADA)
'B~ .
· BSAlMEA #412-91-E
· CSFM #7135-569:115
. NFPA 72
· UL 464
Standard Features
i · Low frequency output.
~, · Low current consumption 17mA @
nominal voltage. (HG124)
· Wide voltage range.
· Screw terminals, separate in/out wiring
option for both horn and strobe.
. Steady or pulsing tone.
Available Models
· Textured finish high impact plastic
faceplate.
. Wide variety of mounting options for new
construction and retrofit applications.
. Supplied with beauty plugs to accom-
modate a variety of installations.
. Xenon Strobe maintains constant flash
rate (1 per sec.) regardless of input
voltage.
. Flush or semi-flush mounting without
the need of a trim plate.
· 15/75 and 30/75 candela strobe op-
tion. Meets ADA 4.28.3 requirements.
· AII11 Oed models exceed requirements
of 4.28.3 of the ADA.
· UL 464/UL 1971 listed for fire protective
service/signal for hearing impaired.
Model
Number
HG124
Operating
Voltage
10-30
Flash
Rates/Min
SHG12-15-1
SHG12-15/75
10-16
10-16
~~_t_ ~ >Y'~~~r~.~ -:- ..:..;::r~~.:~;~~.r-;-:8r:r:~-'1;,!~.
Light Effective
Intensity In
Candela
Combined Rated
Current
@ Nominal
Operating
Voltage
17mA
Combined Rated
Current
@ Maximum
Operating
Voltage
21mA
dB @lD FI.
100
. . _ .~~~ ~1'~~4'$:~~~~~~;r~:
WHEN PLACING AN ORDER: add the following to the end of the model number:
OW' Wall mount and 'R" = Red faceplate
'P' Plain (no lettering) 'W"= Off-White faceplate
'C' = Ceiling mount (1575 models only)
...;~"'.:..."
. ,"41;'
SHG24-15-1 21-30 60 15 95mA
SHG24-15/75-W 21-30 60 15 (UL 1971) 122mA
75 (UL 1638)
SHG24-30/75-W 21-30 60 30 (UL 1971) 159mA
75 (UL 1638)
SHG24-15/75-C 21.30 60 15 (UL 1971) 137mA
75 (UL 1638)
SHG24.11Q.1 21-30 60 110 237mA
Note: 24VDC 15 candela units have a start-up current of 114mA at 1 flash per second.
'\ 15/75 candela units have a start-up current of 130mA (wall)
j 15/75 candela units have a start-up current of 140mA (ceiling)
J 30/75 candela units have a start-up current of 120mA
110 candela units have a start-up current of 148mA
60
60
15
15 (UL 1971)
75 (UL 1638)
130mA
252mA
GENTEX
Architect & Engineering Specifications
The audible or audible/visual signal shall be Gentex model HG
or SHG or approved equal. and shall be listed by Underwriters
Laboratories per UL464 , and when combined with the strobe
option the strobe shall be listed per UL 1971. The notification
appliance shall also be listed with the Califomia State Fire Marshal
(CSFM) and the Bureau of Standards and Appeals (NYC).
The notification appliance shall produce a peak sound output of
90dBA or greater as measured in an anechoic chamber.
The maximum current consumption at 24VDC for the audible
only shall not exceed 17 milliamps and the maximum current
consumption forthe combination audible/visual notification appli-
ance when utilizing a 15cd strobe shall not exceed 95mA at
24VDC.
For those applications requiring the higher output in light
intensity, the maximum current consumption at 24 VDC shall not
exceed the combined current consumption of audible with the
following visual with each candela: 15/75cd shall not exceed 122
milliamps, 30/75 shall not exceed 160 milliamps, 11 Oed shall not
exceed 237 milliamps.
The visual signal shall have a flash rate of 1 Hz regardless of
input voltage.
The notification appliance shall be provided with screw termi-
nals for in and out field wiring and the strobe shall be capable of
operating independently after the audible has been silenced.
The notification appliance shall be capable of mounting to a 4"
square back box and a 2 gang switch box of a minimum of 2 1/8"
Mounting: 4" Square boxes w/brackets 2%" deep minimum in depth. 24 units per carton
4" square metal/non-metallic switch/outlet boxes 2%" deep minimum 11 pounds per carton HG
Gangable 2 gang switch/masonry outlet boxes 2%" deep minimum 16 pounds per carton SHG
Wiring Diagrams
~ HG H(J;l~ AND SHG SERifS POWERED IN PARALLEL
~
........
!lPERVISEO
SO"'-
CJO.lT
\.
SERIES
Dimensions:
~
~ EOlR
2 SHG SERIES WITH H(J;lN AND STROBE POWERED INDEPENDENTLY
Nnl REMOVE ClRCUIT COVER HOUSING AND REMOVE JUMPERS' AND 2
REPlACE COVER AND PROCEED TO WIRE HORN INTO C~CUIT
I
I
I
I
I NDTE: POWER IS SUPPl!!:O TO OEVIC!:S WHEN CONTROL PANEL IS LATCHED.
I
u.. :..!SiEO
Cor..'TRC~
~At..f~
~~fVlSEO
0:;: i'"
\ .
\ .
~
.'.
EOlR
~
~
Ot:::::J~ ~
~~~~
~
~
~
. '.
NOTE: Supplied with beauty plugs to accommodate a variety of installations.
GENTEX
CORPORATION
Fire Protection Products: 10985 Chicago Dr.
30x 310, Zeeland, MI 49464
<216/392-7195, FAX: 616/392-4219
n
t.~ Printed on Recycled Paper
GX120491-16
E'
S
L
N
PRODUCT
3
N FOR MAT
-)
· Intelligent, self-diagnostics
· Field replaceable optical chamber
· Low-profile design
· Plug-in terminal block
· Advanced false alarm immunity
\
J
o N
B U L LET
429 SERIES
Self-Diagnostic,
Two-Wire,
Photoelectric
Smoke Detectors
Model numbers: 429AT. 429C.. 429CT,
429CRT. 429CST, and 429CSST
~
LISTED
<8>
_D
California State Fire Marshal Approvecl
MEA (New York City)
The ESL 429 Series self-diagnostic, two-wire
smoke detectors continually monitor their own
sensitivity and operational status. and provide a visual
trouble indication if they drift out of sensitivity range
or fail internal diagnostics. This meets NFPA 72 field
sensitivity testing requirements without the need for
external meters.
Additional diagnostic information is activated by
applying a magnet near the detector's integral reed
switch. This initiates a self-diagnostic routine and
provides visual indication of sensitivity level. or if service
is required.
The 429 Series is easily cleaneclby simply replacing .
ESL's proprietary field-replaceable optical chamber. All _
models are designed to reduce false alarms from dust.
insects. RFI and external light.
An integral combination rate-of-rise and fixed 13soF
(S70C). 50-foot rated. heat sensm is available with all 'T
model detectors (see selection guide). An integrated
silicon heat sensor and a dedicated microprocessm are
used to detect heat and perform the rate of rise calcula-
tions. for earlier heat detection.
continued
Designator Feature Description
Isolated Fixed Temp. Isolated fixed 1350F (570C) and rate of rise heat detector, independently trips the LED and alarm
relay output. Smoke detector activates internal sounder (local alarm) and auxiliary relay. but
H and Rate of Rise Heat does not latch. Approved as both single station smoke alarm and system heat detector. Ideal for
Detector hotel. motel and dormitory rooms where smoking is allowed.
R Auxiliary Relay Used to activate other devices such as elevator recall, door holders. strobes, etc. Listed for
releasing service. .
.
S Built-in Sounder 85db built-in sounder alarms when smoke is detected or when power wiring polarity is reversed.
Built-in Sounder with 85db built-in sounder alarms when smoke is detected or when power wiring polarity is reversed.
SS Sensitivity Status Also. chirps when unit goes outside the approved sensitivity range for more than one day.
Output Resetting detector will silence chirp for one day. until unit is restored to proper sensitivity.
Integrated Fixed Integrated fixed 1350F (5?OC) temperature and rate of rise heat detector offers double protection.
T Temp. and Rate of Either heat detector or smoke detector can trip and latch LED and alarm relay outputs.
Rise Heat Detector
ESl 429 Series Smoke Detectors
Architectural and Engineering Specifications
The ESL 429 Senes low-profile. self-diagnostic. two-wire smoke
detectors work on the light scattering pnnciple. A pulsed
Infrared light-emitting diode serves as the light source. and a
high-speed photo-diode as the sensing element. When the
amount of light reflected onto the photodiode reaches the
sensitivity setting. the smoke sampling rate increases. Three
(3) successive smoke sensings above the sensitivity setting are
reoUlred to sound an alarm. This design has superior
protection against false alarms caused by dust. insects. RF and
ambient-light
A confirmed alarm causes the normally flashing power
indicator LED to light continuously and the optional alarm
relay (available in "R" models) to operate. A trouble indication
is automatically displayed by flashing the LED every second.
This meets NFPA 72 field sensitivity testing requirements. An
internal 85 dB horn (available in "5" models) emits a steady
tone when the detector alarms and a pulsed tone whe'l
power polanty is reversed. Also available is the "SS" model
which chirps when the unit goes outside the approved
sensitivity range for more than one day. Resetting the detector
will silence chirp for one day. until unit is restored to proper
sensitiVity.
Product Data
Sensitivity... ....................................... max .....
min ...
Operating temperature range .......................
3.1 - 1.O%/ft.
3.) + O.50%/ft.
3rF to ) 200F
OOC to 500C
Operating humidity range ............................... 0 to 95% RH
Minimum voltage --C. CT. CRT. CST. CSST .................... 8.5 \I
-AT ............ .................................... 6.5 \I
Maximum voltage - C. CT. CRT. CST. CSST .................... 33 V
-AT .................................................... 20 \I
Maximum ripple (peak to peak) .................................... 10%
Typical average standby current ................................. 70 ~
Field wiring size............................................... 14 - 24 AWG
Selection Guide
The proprietary optical sensing chamber is field replaceable.
allowing quick and easy cleaning and maintenance.
Models with auxiliary relays are approved for releasing service.
The very low profile 429 Series detectors are equipped with a
hinged cover. a concealed tamper-resistant latch. and insect
screens.
All winng terminates in plug-in. clamp-type screw terminals
The detectors mount to a standard si'lgle-gang electrical box,
a tour-InCh octagonal. four-inch square electrical box. or
WIREMOLD No. 5739 fixture box.
Smoke Detector Spacing
On smooth ceilings (as defined in NFPA 72). spacing of 30
feet (9.1 meters) may be used as a guide. Other spacing may
be used depending on ceiling height. high air movement.
and other conditions or response requirements.
''''I~''='\= =) "."j.,=,@
. I -0-
t
Alarm current .... draws max of 60 mA if not lirAited by panel
Max. avg. polarity reverse current - CST ...................... J 0 mA
Sounder specifications .................................. 85 dB at 10ft.
Heat detector specifications
fixed temp. .......................... 1350F:t 50F (57.20C:t 2.80C)
rate of rise ... 150F/min. & > 1 050F (B.3OC/min. & > 40.60C)
Relay specifications .................... 2A@ 28 \I DC or 120 V AC
Packaging..................... J 0 detectors are packed in a carron
Color ............................................... white cover/white base
with U\I inhibitor to prevent yellowing
2-wire compatibility .................... see ESL Compatibility Index
Listings ............ UL 268. FM. CSFM and MEA (New York City)
for Canadian ULC listed products use 428 senes
CORPORATE H[ADQUARHRS
12345 SW LcvelOll Dr.
Tualallll. OR 97062
Tel.: 503.692.4052
Fax 503691.75()()
U.S. & Canada: 800.547.2556
Tcchnical Service: 800.648.7424
ESLN
A PRODUCT OF SENTROL. INC
Senl 1'01. IllC reserves \ he rIghl
\0 change speciflcallOllS
without nOllce.
"'1995 Senlenl. Inc.
[.1 ~~3.(13q5.I'I.G 15~
600 SERIES
ACCESSORIES
DESCRIPTION
The 606 Series remote indicators are designed for use
with the ESL 600 Series area fire detectors and the ESL
609 Series air duct-type smoke detectors. Model 606U1
is a remote indicator only. Model 606U2 features remote
indicator and key operated test switch. Model 606U3
features remote indicator and key operated test and
reset switch. A single key (Hudson Cat. 30) is supplied.
The terminal numbers on the remote indicators match
terminal numbers on ESL 600 Series area fire detectors
and 609 Series air duct-type detectors. Combination tri-
wall barriers and captive wire clamping plates ensure
secure wiring connections.
All models are constructed of high-impact thermoplastic.
Their decorative design and multi-colored labels make
the 606 Series attractive accessories.
APPLICATION
)
ESL 606 Series remote indicators are ideal for use in
applications where ESL 600 Series fire or air duct-type
detectors are not readily visible or accessible (Le.,
installed in plenums, above suspended ceilings, below
raised floors). Model 606U3 is primarily used to provide
reset for detectors that are u~ed for releasing service,
and that are not connected to' a fire alarm control unit.
INSTALLATION
The 606 Series mount to a standard single-gang
electrical switch box with a minimum depth of 1-3/8
inches (3.43 em). Mounting screws are supplied. All
wiring connections must be made to the remote indicator
before mounting it to the switch box.
APPROVALS
Listed by Underwriters Laboratories, Inc.; California
State Fire Marshal approved (Listing #7300-447:118).
REMOTE INDICATORS
MODEL
DESCRIPTION
606U 1
Remote indicator
-")
606U2
Remote indicator with test
606U3
Remote indicator with test and reset
t:
~.. ......~.IC.\Qo
c....
~--
..,.. -
.,.-
'W'.-
..
<8>
-.
California State
Fire Marshal
Approved
FEATURES
b
.E'5l
Remote Indicators
@
· Remote alarm indication
· Optional remote TEST and RESET functions
· Easy wiring connections to ESL 600 Series
area and duct-type detectors
· Fits standard single-gang electrical boxes
· Wire clamp-type terminals
· Keyed alike to ESL control units and ESL
pull stations
· High-Impact thermoplastic
· Attractive design
PRODUCT DATA
Height:
Width:
Depth:
Distance between screw holes
(center to center):
Indicator rating:
Switch rating:
Single key supplied.
4-1/2 in. (11.25 cm)
2-3/4 in. ( 6.88 cm)
1-3/8 in. ( 3.43 cm)
3-9/32 in. (8.20 cm)
6 VDC, 5 mA
4 A, 125 VAC
600 SERIES ACCESSORIES
DIMENSIONS-ALL MODELS (Model 606U3 shown)
4-1/2"
SCHEMATIC DRAWINGS
820 ohms
04
05
Model 606U1
E'5l
Front View
I
~II':.
2.3/4"
"
/1,
I I
I '
I' I
I '
I
CG_
o .. ~ '" . c
o
3-9/32"
NORMAL
~~:::
820 ohms
Model 606U2
SENTROL, INC.
10831 SW Cascade Blvd.
Portland, OR 97223
Sales: 800-547-2556
Fax: 503-684-9230
Technical Support: 800-648-7424
Distributed by:
Bulletin 2270-S4 September 1992
Appearances and details subject to change without notice.
Side View
~1'3/8"
:1~IJ ~,
Model 606U3
820 ohms
04
05
06
ESL Initiating Devices
1 O~ Series . . . . .
Manual Fire Alarm Stations
· Single and dual actiol! pull stations
· Terminal or pigtail connections
· Semi-flush or surface mounting
~
LJSTIll
Listings
· CSFM approved
· UL approved
· NYC BSA approved ( 103-22. 1 m-22S
and 103-24)
103-20
103-21
103-22
103-22S
103-23
103-24
103-31
103-32
103-42
103-60
103-80
Accessories
103-25
103-26
Single action (SPST) with hex reset
Single action (DPST) with hex reset
Dual action (SPST) with hex reset
Dual action (SPST) with hex reset and NY stripe
Dual action (DPST) with hex reset
Dual action, pre-signal (DPST) with hex reset
Single action (SPST) with key reset
Single action (DPSTI with key reset
Dual action (SPST) with key reset
Weatherproof, single action (SPST) with key reset
Explosion-proof, dual action (DPDT) with key reset
Red, surface back box for 103-20 through 103-42
Replacement glass rod for 103-20 through 103-60
104 Series . . . . . . . .
Heat Detectors
([)
usno
I~~:"
" ~
B · ,~.
, .,.'
~'~
-/-
. , '
Listings
. CSFM approved
. UL 521
. New York, Board of Standards and
Appeals approved
. Complies with NFI':\ 72
~
1.800.547.2556 SENTROL, I NC
I
AI-
ESt.
609 SERIES
AIR DUCT SMOKE DETECTORS
DESCRIPTION
The ESL 609 Series Air Duct Smoke Detectors consist of an ESL 600
Series photoelectronic or ionization smoke detector head, a Model
609UOO duct detector housing, and one selected function card. The
interchangeable sensing head and function card configuration allows
great flexibility in product application.
The assemblies feature a modular design that allows easy selection
of the desired signaling and control'functions. The rugged mechani-
cal design includes a manifold and a clear partitioned cover that
directs all sampled air through the sensing chamber of the selected
smoke detector.
The clear partitioned cover allows viewing of the UNIOUEintegral air
flow monitor which indicates the presence and direction of air flow
through the sensing area of the enclosure. Additionally, the cover
includes a probe port for in-place measurement of the actual air
velocity using an anomometer. The air inlet filter may be visually
inspected through the clear cover for dust and dirt accumulation.
A solid steel conduit mounting plate features knockouts for 1/2 and
3/4 inch conduit and provides continuous grounding between con-
duits. Integral inlet and exhaust sampling tubes, which are suitable
for duct widths of six or more inches, are provided. OPTIONAL
extension sampling tubes are available in two, four, and eight foot
lengths.
This product is approved for use without additional extension
sampling tubes.
NOTE: In some applications, the addition of an optional extension
sampling tube may cause the air flow monitor to stop rotating. This
is a result of the lesser air volume being sampled with the optional
extension tube, mostly attributable to its smaller inside diameter.
Standard features also include a local red LED alarm indicator, local
functional test capability, and a continuity switch for checking the
system wiring.
The integral compartment accepts one electronic function card.
Each'function card is provided with -barrier-type,clamping-plate,
screw terminal strips to accept field wiring connections of wire sizes,
12 AWG through 18 AWG. These terminal strips are designed to
prevent "looping" of wires and provide for supervision of conductors.
Function cards are available in several configurations. Please refer
to pages 2 and 3 for electrical specifications.
APPROVALS
The ESL 609 Series Air Duct Smoke Detectors are for use in commer-
cial fire protective signaling systems, NFPA 71 and 72 (formerly
designated as 72A, 72B, 72C and 72D), and in commercial air
conditioning and ventilating systems (NFPA 90A). Listed by Under-
writers Laboratories. Inc.; California State Fire Marshal Approved
(Listing #3240-447:120); New York City, Board of Standards and
Appeals approved (Calendar No. 122-73-SA); State of Maryland
approved (Permit #1905); City of Cleveland approved (Docket S-5-88).
California State
Fire Marshal
Approved
Patented
':J-. .
.;l..:.:::"-'~
--':T-~ ,.' .-.~
~~_. ~~~..,
- .
FEATURES
@
· Photoelectronic or Ionization Detection
~' Requires NO Extension Sampling Tubes
· UNIQUE Visible Air-Flow Indicator
· Two-wire 12/24 VDC Operation
· Four-wire 120 VAC, 24 VDC, 24 VAC Operation
· Modular Design
· Transparent Housing Covers
· Local Reset Capability
· Local Test and Alarm LED
· Remote Alarm, Test and Reset Capability
· Optional Auxiliary Alarm Contacts
· Optional Supervisory Contacts
· Listed to UL 268A
APPLICATION
The function of an air duct smoke detector is to detect smoke for the
primary purpose of controlling air movement by air conditioning and
ventilating systems, in an attempt to prevent panic and damage from
the distribution of smoke and gaseous products.
The interchangeable detector configuration allows great flexibility in
product application. The ESL 600 Series smoke detectors are suited
for commercial, industrial, institutional and residential fire alarm
systems.
Electronic function cards provide for two-wire and four-wire operation
for alarm initiation and/or releasing service applications. Two-wire
detectors must be connected to UL Listed compatible initiating cir-
cuits. Four-wire function cards for low voltage DC operation. may also
be operated from a nominal 24 VAC power supply, commonly avail-
able in many HV AC applications. For more application information on
the 609 Series function cards, refer to pages 2 and 3.
EQUIPMENT
The ESL 609 Series Air Duct Smoke Detector consists of three
primary elements: a) the sensing head. b) the selected function
card. and c) a housing for the detector and function card.
Duct Detector Housing
The base section of the housing that mounts to the duct wall
includes: a) integral inlet and exhaust sampling tubes. b) a
sensing head mounting base with an automatic-opening continu-
ity switch. c) a conduit connection plate with ground screw, d) the
detector cover/manifold monitor. and e) the function card com-
partment cover.
The 609U01 is an air duct detector enclosure supplied with a
611 UD photoelectronic smoke sensing head. The 609U02 is
supplied with a 612UD ionization smoke sensing head.
Electrical Function Cards
Any of the function cards may be used with the Models 609U01 and
609U02 duct detector assemblies. All function cards include a
local alarm (red) indicator, local test capability. and provision for
remote test and remote alarm indicator connections. All models
except 609Ul0 include a remote detector reset capability. All
models with auxiliary alarm contacts are Listed as suitable for
releasing service applications.
Two-Wire Applications
Three function cards are currently available for two-wire alarm
initiating use. Two-wire detectors must be connected to Listed
compatible initiating circuits. Two-wire function cards do not in-
clude a power-on LED (green). Electrical specifications are shown
in Table 1, below.
Table 1: Electrical Specifications. Two-Wire Function Card Application, Low Voltage DC
i. ; Voltage Standby. . . Alarm Alarm
Range Current Current Contacts 1
Alarm
33 VDC max. 50 uA max. 60 mA max. None
33 VDC max. 50 uA max. 60 mA max. lA. lC (2 Amp)
33 VDC max.j 50 uA max. 2
70 mA max. lA (2 Amp). 2C (10 Amp)
:... -'If t~f1,.~~ ~J):'"~!i~.:~! l "':~ ~,' ,',:
:' M0d81 J." ~Omp8tlb"'ty
~ Number . r~l.l~entlfier'
-':'.,,-,.~. > ,}.,.$fl;:,;.l'.l1.....
Voltage
.: Range
. Standby
609U10
SOD
8.5-44 VDC
609U11
S02
8.5-44 VDC
609U12
S36
8.5-44 VDC
1. Relay contact ratings shown are for a resistive load at 30 VDC or 120 VAC maximum.
2. When the Model609U12 function card is used in a two-wire initiating circuit application, the 10 ampere relay must NOT be programmed
for normally operated releasing service. If the relay were to be programmed in this manner, the standby operating current would be
increased from 50 microamperes to 10 milliamperes.
Low Voltage, Four-Wire Applications
Seven function cards are currently available for low-voltage. four-
wire alarm initiating and releasing service use, or stand-alone
releasing service applications. All of the low voltage four-wire
function cards can be powered from a nominal 24 VAC source.
available in many HV AC applications. Electrical specifications
are shown in Table 2. on the following page.
Line or Low Voltage, Four-Wire Applications
Four function cards are currently available for line voltage (i.e.,
120 V AC nominal). four-wire alarm operation. All four function
cards can be field modified for low voltage, four-wire opera-
tion by cuttIng Jumper J12 located in the upper right-hand
comer of the function card, below terminals 0 and 1. Four-
wire LinelLow voltage function cards INCLUDE a power-On LED
(green). Electrical specifications are shown in Table 3, on the
following page.
220/240 V AC Function Card
The Model609U25 function card is currently the only function card
available for 220/240 VAC, four-wire operation. Electrical speci-
fications are shown in Table 3. on the following page. .
Field Programming of the 10 Ampere Contacts for Releasing
Service.
As supplied, the two. 10 Ampere rated, Form C auxiliary contacts
provided with function cards 609U12, 609U 14, 609U22, 609U24.
609U25, 609U32, and 609U34 transfer on alarm ONLY. The relay
that controls these contacts may be field programmed, by moving
jumper Jl0 from pin P8 to P7, to be energized in the normal
standby condition. so that the contacts transfer on removal of the
sensing head. loss of power to the air duct detector assembly, or
alarm of the sensing head. This may be desirable in many
releasing service applications.
'"
.....
Table 2: Electrical Specifications - Four-Wire Function Card Application, Low Voltage AC or DC
Voltage 2 Amp 10 Amp 1 Amp Power-On
Model Ran~e I Standby Alarm Alarm Alarm su~rvlso~ LED
Number Stan by Current Current Contact3 Contact 3 ontact2, (green)
609U11 8.5-33 VDC 50 uA 48mA 1 Form A - - -
24 VAC 1 Form C
609U31 8.5-33 VDC 9mA 57 mA 1 Form A - - y
24 V AC 1 Form C
609U12 17-33 VDC 50 uA 59 mA 1 Form A 2 Form C - -
24 V AC (11 mA)' (48 mAll
609U32 17-33 VDC 9mA 68mA 1 Form A 2 Form C - y
24 V AC (20 mAp (57 mA)'
--
609U33 17-33 VDC 17 mA 65mA 1 Form A - 1 Form A Y
24 VAC 1 Form C
609U14 17-33 VDC 8 mA 67 mA 1 Form A 2 Form C 1 Form A -
24 V AC (19 mA)l (56 mA)l
609U34 17-33 VDC 17 mA 76 mA 1 Form A 2 Form C 1 Form A Y
24 VAC (28mA)1 (65 mA)'
1. The 10 Ampere contact relay of the 609U12, 609U 14, 609U32 and 609U34 function cards can be field programmed to be normally operated, and
to release on alarm, sensing head removal or power loss, by moving jumper Jl 0 from pin P8 to pin P7. If the relay is programmed in such a manner,
the standby current @24 VDGNAG is increased by 10 milliamperes, and the alarm current is reduced by 10 milliamperes, as shown in parenthesis.
2. The Form A supervisory contact is closed with power applied.
3. Relay contact rating shown are for a resistive load at 30 VDG or 120 VAG maximum.
Table 3: Electrical Specifications - Four-Wire Function Card Application, Line Voltage AC or Low Voltage AC or DC
Voltage 2 Amp 10 Amp 1 Amp
Model Ran~e Standby Alarm Alarm Alarm SU&ervlso~
Number Stan by Current Current Contact3 Contact 3 ontact2,
609U21 102-132 VAC or 15 mA 20 mA 1 Form A - -
17 -33 VDC/24 V AC 1 I 1 Form C
609U22 102-132 VAC or 15 mA 20mA 1 Form A 2 Form C -
17-33 VDC/24VAC'
609U23 102-132 VAC or 15mA 20mA 1 Form A - 1 Form A
17 -33 VDC/24 V AC' 1 Form C
609U24 102-132 VAC or 15 mA 20 mA 1 Form A 2 Form C 1 Form A
17 -33 VDC/24 V AC 1 .
609U25 187-242 VAC 5mA 10 mA 1 Form A 2 Form C -
I I
. .~-~~
1. For Models 609U21, 609U22, 609U23, and 609U24, when converted in the field for low voltage operation the electrical specifications of the similiar low
voltage card in Table 2 apply. For example. if you convert a Model609U21 for low voltage operation use the specifications of a 609U31. For a converted
609U22, use the specifications of 609U32, etc.
2. The Form A supervisory contact is closed with power applied.
3. Relay contact ratings shown are for a resistive load at 30 VaG or 120 VAG maximum.
Sampling Tubes
A pressure differential pulls air in through the inlet sampling tube
and into the sampling chamber, then sends it back out into the duct
through the outlet sampling tube.
Each duct detector housing is equipped with 5.25 inch inlet and
exhaust sampling tubes. The ends of these tubes are cut at a
450 angle. The inlet tube faces upstream and the exhaust tube
faces downstream to ensure airflow through the housing. The
tubes provide the means of obtaining a sample of air from the duct.
Although this product is approved for use without additional
extension sampling tubes, optional tubes may be required by the
authority having jurisdiction. OPTIONAL sampling tubes are
available in several lengths.
"
609 Series Airl:)uct Smoke Detectors
Table 4: Contents of Pre-packaged Duct Detector Models
Pre-packaged Model Number Sensing HeadfType Function Card 1
609UOl 611 UD Photoelectronic None
---
609U02 612UD Ionization None
609U01-ll 611 UD Photoelectronic 6;)9Ull
609U02-11 612UD Ionization 609U11
------ ------. I -----
609UOl-24 611 UD Photoelectronic 600U24 j
609U02-24 612UD Ionization 609U24
------"_.- -----.
609U01-31 611 UD Photoelectronic 609U81
---."----.--.- .. - ----------.---.-- - - --.. u __._._. __~_____ .-----~ - ..--------- ------ -----.- --- --- i
609U02-31 612UD Ionization 609U31 Ji
=:::J
1. For elec/rical specifications of function cards, see Tables on previous pages.
PRODUCT DATA
Accessories Dimensions:
Length: 16.5 in. (42 cm)
All function cards provide for remote alarm indicator and/or remote Width: 5,5 in. (14 cm)
test capability when used in conjunction with the ESL 606 Series Depth: 4.0 in. (10 em)
accesories: Model 606U1 Remote Alarm Indicator or Model 606U2 Integral sampling tubes extend the width by 5.5 inches and require two
Remote Test and Alarm Indicator. All four-wire function cards holes of 2 inches diameter for clearance
include an extra terminal to facilitate connection of a local or remote Weight: -
detector alarm reset switch for use with the ESL Model 609URS Maximum weight is 713.75 oz. (2.23 kg.)
Reset Switch or Model606U3 Remote Alarm Indicator with Remote Operating Temperature Range:
Test and Reset. See Table below for additional accessories. 0-500C, 32-1200F
~-- - Operating Duct Air Velocity Range:
Model Description 300-2000 fUmin. when the 612UD is installed within the duct hOLlsing
Number 300-4000 fUmin. when the 611 UD is inEtalled within the duct housing
606Ul Remote Indicator SPECIFICATIONS
606U2 Remote Indicator with Keyed Remote Test This Air Duct Detector shall be either an ESL Model 609U01 Photoelec-
tronic Detector, Enclosure assembly or an ESL Model609U02 Ionization
606U3 Remote Indicator with Keyed Remote Test Detector, Enclosure assembly.
and Reset
1----- The base of the enclosure and the manifold shall be constructed of solid
205A Inlet Sampling Tube Extension-2 ft. structural foam, and shall incorporate an air-tight smoke chamber in
- compliance with UL268A, Standard for Smoke Detectors for Duct Appli-
2058 Inlet Sampling Tube Extension-4 ft. cations. The detector enclosure shall be equipped with an integral
----,-- --
205C Inlet Sampling Tube Extension-8 ft. mounting base capable of accomodating either a photelectronic or ioniza-
--- tion detector head and shall be capable of local testing via a magnetic
605A3 Test Tool switch. The clear covers for the enclosure shall be constructed of Lexan.@
-- -- -----
204A Power SuperviSion Unit 12 VDC systems The detector shall operate at air velocities of 300 feet per minute to 2000
feet per minute utilizing a 612UD sensing head, and 300 - 4000 feet per.
910-4 Power Supervision Unit 220 V AC systems minute utilizing a 611 UD sensing head. The duct detector shall be
- ---"--"- capable of interfacing directly with ESL 606 Series Remote Stations-
609URS Local Reset Switch, N/C with 6" Leads which shall provide for local alarm indication and test functions. Local or
Remote Reset capability shall be provided for utilizing the Models
Replacement Parts 609URS or 606U3 respectively.
r~-"~d!I.Numb~__ De."'ption -------1 An integral filter system shall be included to reduce dust and rpsidue
accumulation which could cause adverse effects on the sensing head
620010228 Foam Filler and the enclosure. A UNIQUE air flow monitor shall be included to
-------------.--..-..- -------.---.--- --- indicate the presence of air flow through the detector. Air duct detector
672200068 Round Duct Mounting Gasket shall comply with the requirements of UL268A without the attachment 01
----- -.-.-- ------- any sampling inlet or exhaust tube(s). Extension sampling tubes, where
66809084A Relay - 10 Amp required, shall be easily installed after the housing is mounted to the duct
Sentrol, Inc. by passing them through the duct detector enclosure.