Loading...
HomeMy WebLinkAbout96-6066 ?y<F - BUILDING PERMIT 0 so .tJ"IJ CITY OF ZEPHYRHILLS Permit N. (813) 788-6611 60668 -- /,-,2 7-PC 37-.!> ~ vV Date BUILDING b I. (TV ELECTRICAL .-5~..... ai) PLUMBING 3{). UV MECHANICAL Sewer Conn I.d...? y~ o-l? Water Conn: 3-SCi. trO Water Meter: / /J.....,:> -: dV T.I.F.'S:{1i'd. (,'1);a-J ,.;2J-?7 ~ ~ Property Owner: Iv\ Job Address: 'I~. d'. "::L Parcell.D.I )5-()h-Jj, -3 ~3o - /7 Zoning: Description of Work -.f. NO OCCUPANCY BEFORE C.O. -..?QO ....... / Complete Plans, Specifications and Fee Must Accompany Application. All work shall be performed in accordance with City Codes and Ordinances. Inspector Ee Permit Fee~.' t!/V Signature. '1A M - (" ,J.? ~ Company Address Telephone# Valuation or "- 1-7 ~ c/D Contract Price ~ tJ / /' ~- ./ City License Registration # :J Y-5 State Certified License# 6 /L.~ L3. JvvJh //; ~ .g 4 AlA 'YI / ().,/ A~7~ BUILDING ELECTRICAL PLUMBING MECHANICAL Ftr. q....5-q~ ~!3 PreSLB q-3~~ Lintel i-~j- i~~~P FRM. /....). /9 ~ .. .. Const. Pole Insul. CL Pool WL //-lj~Cj? BJLJ.-.. Pre-Meter J-'J.9'J JiJJ5 Final &100 '1- 3- f1i.Q ~ ~ID"'9...f{~M SLB R'1J - <f~A43 Tub Set -JS-~ 9hlV/L Water Sewer 1-1.-97,[:,1..1 ~ Final Breakers Ducts Insl.//-Jf?J9/n1Stf)8 . Tp. Servo Rough In /J-l~. 91.0 6lk.B Meter Can ~.02.'-9L , Compressor Final Driveway REINSPECTION FEES: When extra inspection trips are necessary due to anyone of the following reasons, a charge of Fifteen and 00/100 Dollars ($15.00) shall be made for each trip for each trade: <j I 7f..1' /f ~~-? 6 a. Wrong Address M /f ~I' ~~~Q.F ~: ~~;~~:~re~O~~~~i~~~U~~~grJ~~~ :~~~Yi~~;:~~~:~i~~iled. ~ J I -- d- / - Y 7 d. Work not ready for inspection when called. ~ e. Permit not posted on job site. f. Plans not at job site. g. Work not accessible. The payment of inspection fees shall be made before any further permits will be issued to the person owning same. BUILDER: Russell Brown ADDRESS: ... Silver Circle 11 '7 .Q.. 9 OWNER: RADON GAS: I $ PERMIT FEES:I $ CONNECTION FEES:1 $ WATER METER:I $ /' 18.17 , 541.00 , 1,828.00 , 185.00 , TRANSPORTATION IMPACT FEES: 99% 1% $ 1,480.00 $ 1,465.20 $ 14.80 CREDIT:I $ SUB-TOT Aq S IRRIGATION METERI $ 50.00 I 3,832.17 l 165.00 I TOTALI $ 3,997.171 APPLICATION FOR PERMIT CITY OF ZEPHYRHILLS BUILDING DEPARTMENT 1~Y ;O'u0 OWNER'S NAHlL-C;:< l) 5 S 'E I- L Y\"\. <B Ro w ,.....( PHONE ~-:-; '3 () - I i.-g '2. q- OWNER'S ADDRESS 15::<'35 A b:J ~ EL~ COOR.T z '\1 ILLS FL 3, 35Lf- L JOB ADDRESS 4- f '2 C{ 5 I L VEf2 (':../ R eLl':::) :2.-' ,~ I tL s: f::L 33 s- 4- \ LEGAL DESCRIPTION: LOT(S) BLOCK SUBDIVISION C\i l4 L Fa....,.. V\l LV\ <;;. PARCEL J.D.' (OBTAIN FROM PROPERTY TAX NOTICE) WORK PROPOSED:~ew Construction ____Addition ____Alteration ____~epair ____Install ____Sign _Move ____Demolish PROPOSED USE: ~Single Fa.ily _"IF ____, of Units ____"/H ____Conaercial _Indust. ____Swim. Pool _Other ____Restaurant & Health Department Approval DESCRIPTION OF WORK: f< ~&'S'TKAr:D Y'V\oD6L Y:\\3S0L\.) , S- f L' I . I ~ i 7 a ( BUILDING SIZE: 3q X~5'b2 ~ Square Feet. 0 Height RESIDENTIAL: ATTACH (2) PLOT PLANS & (2) SETS OF BUILDING PLANS & (1) SET ENERGY FORMS. COMMERCIAL: ATTACH (3) SETS OF BUILDING PLANS & (1) SET ENERGY FORMS. PROPERTY SURVEY REQUIRED FOR ALL NEW CONSTRUCTION. PERMITS REOUESTED v/BUILDING ~LECTRICAL ~ MECllAliICAL ~PLtJHB~NG $ IDa Valuation of Total Construction AKP Service ,/ Florida Power Corp. W.R.E.C. $ Valuation of Mechanical Installation GAS ROOFING SPECIALTY TYPE OF CONSTRUCTION: .LBlock _Fralle ____Steel Other FINISHED FLOOR ELEVATIONS: FT. IS PROJECT IN FLOOD ZONE AREA? V YES NO ****************************************** BUILDER CONTRACTOR SECTION COMPANY SU SSGLL ~ . ~ RO~7/'\ c:J State Cert. or Regist. # '{t,CO (..l, ,\ \ 7'itL'lteLl M. ~ "8L-'-^. . City License Registration' .7_Lf- '3 ****************************************** Signature ELECTRICIAN SiRlUlture q:(, I M QLt COMPANY Cf?USSGLL M '?,QOLu/'J 1f\'1 0 \-...-.,.. _ State Cert. or Regist. #I R n ()() I 0 ~i5 , ~l~ ~~.~ City License Registration f \L,~ ******................*..****....****.*..* PLUKBER o ~ COMPANY liUC;SGLL n1. hRDLAJI--.t. State Cert. or Regist.' C\---=- CO 3<1 q c~ (. ' fY\, S2:nnL.t..N\..... City License Registration #I In'? ***...*.**.......*****.**...****..***..*.. Signature Signature Q~ COMPANY <:f< USSELl IV'\b ROld "J M ~ State Cert. or Regist. :9 c.. t1CL.; Lf--l 2.54- , r I , :1::::>~ City License Registration f I" *.********.~**********.****.*******.****** MECHANICAL OTRF.R COMPANY State Cert. or Regist. f Signature City License Registration f ***********.*.*.*****.*******.*******.***. APPLICATION APPROVED BY PERMIT OFFICER. CONDITIONS OF PERMIT AFFIDAVIT A. NOTICE OF DEED RESTRICTIONS The undersigned understands that this perait lay be subject to Ideed restrictions" which lay be lOre restrictive than City regulations. Tbe undersigned assUles responsibility for cOlpliance with any applicable deed restrictions. B. UNLICENSED CONTRACTORS AND CONTRACTOR RESPONSIBILITIES If tbe owner has bired a contractor or contractors to undertake work, they lay be required to be license~ in accordance with state and local regulations. If the contractor is not licensed as required by law, both the owner and contractor lay be cited for a lisdeaeanor violation under state law. If the owner or intended contractor are uncertain as to what licensing requirelents lay apply for the intended work, they are advised to contact the City of Zephyrhills Building Departlent, (813) 788-6611. FurtherlOre, if the owner has hired a contractor or contractors, he is advised to have the contractor(s) sign portions of the "Contractor Sections" of this application for which they will be responsible. If you, as the owner sign as the contractor, you are indicating that you, rather tban the contractor, are responsible for the work. If the contractor wishes you to sign as contractor that lay be an indication that he is not properly licensed and is not entitled to perlitting privileges in the City of Zephyrhills. C. TRANSPORTATION IMPACT FEES AND UTILITY CONNECTION FEES D. CONSTRUCTION LIEN LAW (CHAPTER 713, FLORIDA STATUTES, AS AMENDED) I certify that I, the applicant, bave been provided with a copy of "Florida's Construction Lien Law - Hoaeowner's Protection Guide" prepared by the Florida DepartJent of Agriculture and ConsUler Affairs. If the applicant is sOleone other than the lowner", I certify that I bave obtained a copy of the above described docUlent and prolise in good faith to deliver it to the "owner" prior to coltencelent. E. CONTRACTOR'S/OWNER'S AFFIDAVIT I certify that all the inforlation in this application is accurate and that all work will be done in cOlpliance with all applicable laws regulating construction, zoning, and land developlent. Application is hereby lade to obtain a perlit to do work and installation as indicated. I certify that no work or installation bas cOIIenced prior to issuance of a perlit and that all work will be perforaed to leet standards of all laws regulating construction, City codes, zoning regulations, and land developlent regulations in the jurisdiction. I also certify tbat I understand that the regulations of other governtental agencies tay apply to tbe intended work, and tbat it is IY responsibility to identify what actions I lust take to be in cOlpliance. Sucb agencies include but are not lilited to: * DepartJent of Environaental Regulation - Cypress Baybeads, Wetland Areas and Environaentally Sensitive Lands, Water/Wastewater TreatJent t Southwest Florida Water Hanagelent District - Wells, Cypress Bayheads, Wetland Areas, Altering Watercourses * ArlY Corps of Engineers - Seawalls, Docks, Kavigable Waterways * DepartJent of Healtb & Rehabilitative Services, Environaental Health Unit - Wells, Wastewater 'I'reatJent, Septic 'I'anks t US Environaental Protection Agency - Asbestos abateaent I also certify tbat, if fill laterial is to be used in Flood Zone "An or "A,etc.., it is understood that a drainage plan addressing a .colpensating volUleH will be subtitted which is prepared by a professional engineer registered in the State of Florida prior to perlit issuance. A perlit issued shall be construed to be a license to proceed with the work and not as authority to violate, cancel alter, or set aside any provisions of the technical codes, nor shall issuance of a perlit prevent the Building Official frOl thereafter requiring a correction of errors in plans, construction, or violations of any code. Every perait issued sball becOle invalid unless the work authorized by such perlit is coltenced within Sil IOnths of issuance, or if work authorized by the perlit is suspended or abandoned for a period of Sil IOnths after tbe tile the work is cOllenced. One 90 day extension of tite, JaY be allowed for the pe~it with fee charge of $15.00. The extension shall be requested in writing to the Building Official. An approved inspection lust be logged during each ail IOnth period, or the project will be considered abandoD~d. WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMEKT HAY RESULT IN YOUR PAYING TWICE FOR IHPROVEMEH'l'S TO YOUR PROPERTY. IF YOU IHTEKD TO OBTAIK FINANCING, COKSULT WITH YOUR LEKDER OR AN ATTORKEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. JOBS UNDER $2,500 IN VALUE DO KOT NEED '1'0 RECORD AND POST A II NOT ICE OF COMMENCEMENT". ~p1A fJ1. gJ{~ SIGNATURE: OWKER OR AGEH'l' SIGNATURE: COH'l'RACTOR STATE OF FLORIDA COUNTY OF The foregoing instrument was acknowledged before me this 19 by who is personally known to me or who has produced as identification and who did/did not take an oath. STATE OF FLORIDA COUNTY OF ----Ft:LSQD The foregoing instrument was acknowledged before me thisdl ot ~. , 19~ by R.u-sse./l rn. ~VGlLJ...:)~ who is personally known to me or who has produced FL-J,)L~BloSO.:r33~5a-371- D as identification and who did/did not 1~~eJ~L Ie- L. ~~h~ (Name Typed, Printed or S amp d) NOTARY PUBLIC (Signature) (Name Typed, Printed or Stamped) NOTARY PUBLIC ,""'~:t."'t" JAMIE L. MURPHY l~ ~t.>\ MY COM"'ts..'lION 11 CC 466180 EXPIRES. Ap"! 27,1999 BondId TllnI NotaIy NlIIc t.hIIIwdIIInI L III \ l- t 0 H -r- V I L ~-.- 1-\5 / 7/10 y J- ~-rT Jr 1+ / Z q 5\LVEn t'.;oo h. .3 \ P 'H (: ) Clf<CLL l LoT \\ i --k- i 5L(-.0 I i } 7,5 / - ( ~Sq ,0 1?~ ~~~_ __'~LQ,l_ f 1 b s ~~J~ytg.._ , I I I : I I -f- L__________ I I i I I -.-----------j I Y / '2J..) ,"'~', . I ! / /~ / 4::;(,1 : i 1 IO.t) I,:J [\1 A I . Department of C~mmunity Affairs. FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION FORM 600A.93 Residential Whole Building Performance Method A CENTRAL 4 5 6 AND ADDRESS: BUILDER: PERMITTING l.AJf.-1 OWNER: 17 US 1. New construction or addition 2. Single family detached or Multifamily attached 3. If Multifamily-No. of units covered by this submission 4. If Multifamily, Is this a worst case (yes / no) 5. Conditioned floor area (sq. ft.) 6. Predominant eave overhang (ft.) 7. Porch overhang length (ft.) 8. Glass type and area: a. Clear glass b. Tint, film or solar screen 9. Floor type and Insulation: a. Slab on grade (R-value + perimeter) b. Wood, raised (R-value + sq. ft.) c. Concrete, raised (R-value) 10. Net Wall type, area and Insulation: a. Exterior: 1. Concrete block (Insulation R-value) 2. Wood frame (Insulation R-value) . 3. Steel frame (Insulation R-value) 4. Log (Insulation R-value) b. Adjacent: 1. Concrete block (Insulation R-value) 2. Wood frame (Insulation R-value) 3. Steel frame (Insulation R-value) 4. Log (Insulation R-value) 11. Ceiling type, area and insulation: a. Under attic (Insulation R-value) b. Single assembly (Insulation R-value) 12. Air distribution system: a. Ducts (Insulation + Location) b. Air Handler( Insulation + Location) 13. Cooling system: (Types: central-split, central-single pkg., room unit, PTAC., none) 14. Heating system: (Types: heat pump, elec. strip, nat. gas, L.P. gas, room or PTAC, none) 15. Hot water system: (Types: elec., natural gas, solar, L.P. gas, none) 16. Hot Water Credits: a. Heat Recovery (HR) b. Dedicated Heat Pump(DHP) 17. Infiltration practice: 1,2 or 3 18. HV AC Credits (Type in Letter designation: CF-Ceiling Fan, CV-Cross vent, HF-Whole house fan, RS-Attic radiant barrier, MZ-Multizone) 19. EPI (must not exceed 100 points) a. Total As-Built points . b. Total Base points EPI = Total As-Bul" points X 100 Total Base points I hereby certify that the plans and specifications covered by the calculation are In compliance with the Florida Energy c~ ~ PREPAREDBY:.~OU M. -"n~ DATE: g_1( .qb I hereby certify that this building Is In compliance with the Florida Energy Coda. OWNER AGENT: DATE: 12a. 12b. 13a. 13b. 13c. 14a. 14b. 14c. 15a. 15b. 16a. 16b. 17. 18. '19. 19a. 19b. 1. 2. 3. 4. 5. 6. 7. sq. ft. ft. ft. Double Pane sq. ft. sq. ft. Yv\ . CLIMATE ~ 0 0 OFFICE: Z EPH'If2 t{ \ Us. lONE: 4 ~ 5 6 PERMITNO.~ JURISDICnONNO.: ~ Please T CK NEW c..OH ~~ N-~ 124-~ /'3 (.,.0 Single Pane q5 sq. ft. sq. ft. 8a. 8b. 9a. R= 2 , - I. ft. 9b. R= , . sq. ft. 9c. R= , - sq. ft. 10a-1 R= I'G sq. ft. 10a-2 R= II sq. ft. 10a-3 R= sq. ft. 1 Oa-4 R= sq. ft. 1 Ob-1 R= sq. ft. 10b-2 R= \\ClCi) sq. ft. 10b-3 R= sq. ft. 10b-4 R= ____sq. ft. lla. R= \'l sq. ft. 11b. R= sq. ft. R= c::,.~, __ (condJuncond.) R= (;.., . 5; ,__ (condJuncond.) Type:C.~N-m~L~.sPL.I, SEER/EERlCOP: I 0 Capacity: 7...3. 0 'tV\. %h< ,. Type: \4E\4T PU~? . HSPF/COP/AFUE: "0 /3.. 0 )- Capacity: z...L' Co "^~ '^ Type: ~L \::c. . EF: . 8 Ci ~: { C-.FJHF . ,5 J \/ '11 \ 2.~t'\,,"'L Review 01 plana and specifications covered by this calculation Indicatea compliance with the Florida Energy III const Is completed, thla building will be inspected lor compliance in a Section 53.908, F.S. ~ SUMMER CALCULATIONS J BASE I BASE GLASS ~ SINGLE- GLASS x SUMMER = SUMMER SUMMER PO AREA PT. MUL T. POINTS AREA CLEAR N Zb 82.2 -2 I ~'1 N 2'- (51.0J NE 82.2 NE "'11. E 1l1.. 82.2 115/ E 14 (109. U SE 82.2 SE Tff S 55 82.2 LL .:;;? \ S C;.c:; (100 f.) SW 82.2 SW 112.9 W 82.2 W 109.2 NW 82.2 NW n.2 H' 82.2 H' 367.7 ~ :5 CJ T l' .15 t COND 1 TOTAL I BASE 1 BASE I ADJUSTED FLOOR GLASS i ADJUST. i GLASS = GLASS AREA i AREA FACTOR SUBTOTAL T BASE SP .15 I I C/, l.q I I 1 ~ 0 ~ I /..c;"'7, ")5 4. .., COMPONENT -'- BASE SUMMER I BASE COM AREA SUMMER DESCRIPTION x POINT. MULT. = POINTS DESC EXTERIOR CUt 1.0 Cfll RLO ~ ADJACENT '<.?'.? .7 '2-"2..(;" FR \0\ rn EXTERIOR 8 ADJACENT ,. ~~ 11 4.8 1.6 PANE DOUBLE.PANE INT MUL T. OR SUMMER POINT MUL T. TIN'r CLEAR TIN'r 51.5 47.8 43.5 76.6 71.7 63.4 107.1 102.0 87.3 11 0.3 104.1 89.4 98.3 90.9 78.8 110.3 104.1 89.4 107.1 102.0 87.3 76.6 71.7 63.4 303.3 324.6 238.1 ,. ~ II~~\~~ CJ UNDER ATTIC J~C1'< .6 11~ t< - I q I 7... qr'~ I' \ J 4. 22 z OR SINGLE .6 ::::J iil ASSEMBLY 0 BASE CEILING AREA EQUALS FLOOR AREA DIRECn Y UNDER CEILING, AS-BUILT CEILING AREA EQUALS ACTUAL CEILING SQUARE FOOTAGE ,. ,. '2-0 \~ E~ ,. a: SLAB (PERIMETER I G5 -31.8 - 59 (J.., S-O-b-. Ib5 -'<,,\ ,0( - -=) ?JJ 4- g RAISED (AREA) .3.43 It FOR SLAB ON GRADE USE PERIMETER LENGTH AROUND CONDITIONED FLOOR. FOR RAISED FLOORS USE AREA OVER UNCONDITIONED SPACE. INALTRATION 10.9 TOTAL COMPONENT BASE SUMMER POINT: COOLING BASE COOLING TOTAL BASE SYSTEM x SUMMER SYSTEM M L TIPLlER POINTS .37 25f/'g ,. ,. IO'C( ,. \3b03 ,. \ 'is' Z. "L. '3, , HOT WATER SYSTEM AS-BUILT HOT WATER SYSTEM DESC. I BASE x HOT WATER = MULTIPLIER 3527 AS-BUILT = COOLING POINTS 5~'bl NUMBER OF x BEDROOMS ~ 'H = HORIZONtAL GLASS (SKYLIGHTS) 'FOR GLASS WITH KNOWN SHADING COEFFICIENT, SEE SECTION 1.1 OF APPENDIX C. TINT MULTIPLIERS MAYBE USED FOR GLASS WITH SOLAR SCREENS. FILM, OR TINT. .2- SUMMER POtNT MULTIPLIERS (SPM) CLIMATE ZONES 4 5 6 6A.1 SUMMER OVERHANG FACTORS (SO ~ FOR SINGLE AND DOUBLE PANE GLASS. ~r OH RATIO .QO..11 .12-.17 .18-.26 .27-.35 .36-.46 .47-.57 .58-.70 .71-.83 .84-1..18 1.19-1.72 1.73-2.73 2.74+ N 1.00 .94 .91 .87 .83 .79 .75 .72 (.69) .62 .56 .50 NElNW 1.00 .4 .91 .85 .79 .72 .68 .63 -:58 .50 .40 .36 ti~ ElW 1.00 f. 5) .92 .85 .78 .70 .64 .58 .52 .42 .33 .26 ~l SElSW 1.00 .13 .90 .81 .72 .62 .55 .49 .42 .33 .27 .22 S 1.00 /.91 ) .87 .n .67 .57 .50 .45 .39 .32 .28 .25 . Oft. 'Hf' 11,~ft ?It 3ft 3%ft 4% ft. 5!hft. 6!hft. Q!hft. 14 ft 20ft.. 'To select no lIAr! of tWwI shaH be more lhan 8 ft. below lhe 0VllIhana. 6A-2 WALL SUMMER POINT MULTIPLIERS SPM , FRAME WOOD EXT ADJ 6.4 2.2 2.3 1.9 1.7 1.0 .6 STEEL EXT ADJ 8.9 2.9 4.1 1.3 3.0 1.0 2.8 0.9 2.4 0.8 1.3 0.4 .3 .2 6A-3 DOOR SUMMER POINT MULTIPLIERS SPM) DOOR TYPE EXTERIOR ADJACENT WOOD INSULATED 7.2 2.4 6A-5 FLOOR SUMMER POINT MULTIPLIERS SPM SLAB-ON-GRADE RAISED EDGE INSULATION CONCRETE R-VALUE R.VALUE SPM 0-2.9 0-2.9 -1.0 3-4.9 3-4.9-1.7 5-6.9 5-6.9 -1.7 CONCRETE BLOCK' INT. INSULATION NORMAL wr. EXT ADJ 2.5 .9 1.4 .7 1.0 .6 .8 .4 .3 .2 .1 6A-4 CEILING SUMMER POINT MULTIPLIERS (SPMI UNDER Arnc SINGLE ASSEMBLY CONCRETE DECK ROOF R-VALUE SRII R-V ALUE SPM CEILING TYPE 19-21.9 (1.1 ) 10-10.9 3.0 R.V ALUE DROPPED EXPOSED 22-25.9 n. 11-12.9 2.7 10-13.9 3.0 3.3 26-29.9 .7 13-18.9 2.4 14-20.9 2.0 2.1 30-37.9 .6 19-25.9 1.8 21 & Up 1.4 1.3 38 & UP .4 26-29.9 1.1 :.In Rolin nll RAISED WOOQ2 POST OR PIER STEM WALL wI UNDER CONSTRUCTION FLOOR INSULATION SPM SPM 0.9 -5.8 -1.1 -2.8 -1.0 -2.2 ADJ~CENT SPM 5.3 2.1 1.8 6A-6 INFILTRATION SUMMER POINT MULTIPLIERS (SPM) INFILTRATION PRACTICE SPM SEE TABLE 6A.21 PRACTICE #1 PRACTICE #2 6A-7 DUCT MULTIPLIERS OM SUPPLY DUCTS IN UNCONDITIONED SPACE RETURN DUCTS IN CONDITIONED SPACE 1.10 1.07 1.06. 1.00 1.00 SUPPLY DUCTSIN CONDITIONED SPACE3 6A-8 COOLING SYSTEM MULTIPLIERS (CSMI SYSTEM TYPE COOLING SYSTEM MULTIPLIERS CSMI Central Units (SEER) Rating 7.5-7.9 8.0-8.4 8.5-8.8 8.9-9.4 9.5-9.9 10.Q;J.O.4 10.5-10.9 11.0-11.4 11.5-11.9 12.0-12.4 CSM .45 .43 .40 .38 .36 /34 .32 .31 .30 .28 PTAC & Room Units (EER) Ratina 12.5-12.9 13.0-13.4 13.5-13.9 14.0-14.4 14.5-14.9 15.0-15.4 1~.9 16.0-16.4 16.5-16.9 17.0-17.4 17.5 & Up CSM .27 .26 .25 .24 .24 .23 .22 .21 .21 .20 .19 MINIMUMS: CENTRAL UNITS-AIR COOlED SPlIT SYSTEM 10.0 SEER, SINGLE PKG. 9.7 SEER, GROUND WATER HEAT PUMP 11.0 EER. PTAC-SEE TABlE 6.2 6A-9 HOT WATER MULTIPLIERS (HWM) SYSTEM TYPE HOT WATER MULTIPLIERS (HWM Electric Resistance EF .SO-.81 .82-.83 .84-.85 .86-.87 .88~ .91-.93 .94-.96 .97 & Up HWM 3879 3785 3695 3609 (3527 I 3411 3302 3200 Natural Gas EF .43-.47 .48-.49 .50-.51 .52-.53 .54-.55 .56-.57 .58-.59 :&J::lfI .62-.63 .64-.65 .~.!!JIL HWM 2974 2664 2558 2459 2368 2284 2205 2132 2063 1998 1938 LP Gas HWM 3638 3259 3129 3009 2897 2794 2697 2607 2523 2444 2370 1 FOR MULTIPLIERS FOR OTHER TYPES OF CONCRETE BLOCK CONSTRUCTION SEE SECTION 2.1 OF APPENDIX C. 2 MULTIPLIERS FOR OTHER TYPES OF RAISED WOOD ASSEMBLIES SEE SECTION 3.1 OF APPENDIX C. 3 DUCTS IN CONDITIONED SPACE NEED TO BE INSULATED ONL no THE R.VALUE NECESSARY TO PREVENT CONDENSATION. .3. WINTER CALCULATIONS .15 COMPONENT AREA = AREA DESCRIPTION = EXTERIOR 1.1 ::l ADJACENT 2 1.8 ~ " " rn EXTERIOR ~~ 5.1 IOL I I T~S~L~I ~O .~ t C~ \.~1: 4.0 ,'"2- 8 ADJACENT ~ " " CJ UNDER Arnc I "Z '-(....!. .6 ,'I (." 7< _I C( \'t.'1'3. \. 0 I? C1 <. z OR SINGLE .6 ::J ii:i ASSEMBLY .6 0 BASE CEILING AREA EOUALS FLOOR AREA DIRECTLY UNDER CEILING, AS.BUILT CEILING AREA EQUALS ACTUAL CEILING SQUARE FOOTAGE. IX SLAB {PERIMETER I to ..::::;- .1.9 -3, \4- c:. -()- fir I (.., .::; '2.'5 'T ('1 0 RAISED (AREA) . .2 0 it FOR SLAB ON GRADE USE PERIMETER LENGTH AROUND CONDITIONED FLOOR. FOR RAISED FLOORS USE AREA OVER UNCONDITIONED SPACE. N NE E SE S SW W NW HI ~ j CJ I ,I I ,j INFILTRATION BASE = WINTER POINTS 4.1 CUMATE ZONES 4 5 6 GLASS ~ SINGLE-PANE O'R DOUBLE-PANE .t WINTER lAS-BUILT WINTER POINT MUL T. WINTER POINT MUL T. x OVERHANG = GLASS AREA CLEAR TItfrZ CLEAR TItfrZ FACTOR (&A-l0) WIN. PTS N 'L G:. (9,6/ 9.6 5.6 6.1 \.7_ 500 NE .-:h 7.3 3.5 4.2 E \4- (- 2. ~ - 2.0 - 5.6 - 3.6 '"l \ -2"2.- SE ~ - 9.7 -13.4 .10.4 S 55 (,10. lJ -10.2 -14.0 -11.0 ''1_~ -..:::>"lO SW -10.3 - 9.7 -13.4 -10.4 W - 2.2 - 2.0 - 5.6 - 3.6 NW 7.4 7.3 3.5 4.2 HI -32.1 -28.0 -27.0 -21.5 " AS-BUILT GLASS SUBTOTAL " . , " GLASS AREA x .1....'. j j 'I ~ -' ~ ~ HEATING SYSTEM 2FOR GLASS WITH KNOWN SHADING COEFFICIENT, SEE SECTION 1.1 OF APPENDIX C. TINT MUL TIPUEAS MAYBE USED FOR GLASS WITH SOLAR SCREENS, FILM, OR TINT. -4- WINTER POINT MULTIPLIERS (WPM) CLIMATE ZONES 4 5 6 6A-10 WINTER OVERHANG FACTORS IWOFl J OH RA no I .00-.11 I .12-.17 .lB-.26 .27-.35 .36-.46 I .47-.57 .5B-.70 I .71-.B3 I .84-1.1B 1.19-1.72 11.73.2.73 I 2.74+ SINGLE PANE GLASS ~ N 1.00 1.03 1.05 1.0B 1.10 1.13 1.15 1.lB 7 1.20 ) 1.24 1.29 1.34 NE/NW 1.00 1.07 1.10 1.15 1.20 1.25 1.30 1.35 1.39 1.5L1 1.59 1.67 ENI 1.00 .<71./ .57 .19 -.20 -.65 -1.05 -1.4B -2.03 -3.01 -4.06 -5.04 SE/SW 1.00 .93 .90 .BO .68 .54 .39 .22 .05 -.33 -.71 -1.01 I-a: S 1.00 /.95 / .92 .B3 .70 .54 .36 .13 -.13 -.70 -.9B -1.09 ~[ DOUBLE PANE GLASS N 1.00 1.05 1.07 1.11 1.14 1.lB 1.21 1.24 1.2B 1.34 1.40 1.47 NE/NW 1.00 1.11 1.16 1.24 1.32 1.41 1.4B 1.56 1.63 I.BO 1.94 2.0B ENI 1.00 .BB .B2 .66 .50 .31 .15 -.03 -.26 -.66 -1.10 -1.50 SE/SW 1.00 .95 .92 .B5 .76 .65 .54 .41 .2B -.01 -.30 -.52 S 1.00 .96 .94 .B7 .7B .65 .51 .33 .13 -.30 -.51 -.60 OH LENGTH' Oft. 1 ft. 1% ft. 2ft. 3ft. 3% ft. 4% ft. 5% ft. 6% ft. 9% ft. 14ft. 20ft.+ 'TO SELECT BY OVERHANG LENGTH, NO PART OF GLASS SHALL BE MORE THAN 8 FT. BELOW THE OVERHANG. 6A.11 WALL WINTER POINT MULTIPLIERS FRAME WOOD EXT ADJ 6.B 5.3 2.5 2.1 2.0 .B 1.B CONCRETE BLOCK' INT. INSULATION NORMAL WT. EXT ADJ 6.0 3.1 3.B 2.3 2.9 1.9 .3 1.5 1.1 .7 .5 6A-12 DOOR WINTER POINT MULTIPLIERS 6A-13 CEILING WINTER POINT MULTIPLIERS IWPM\ DOOR TYPE EXTERIOR ADJACENT UNDER ATTIC SINGLE ASSEMBLY CONCRETE DECK ROOF R-VALUE WJ:IM R-VALUE WPM CEILING TYPE WOOD 7.6 5.9 19-21.9 ( 1.0 ) 10-10.9 loB R-VALUE DROPPED EXPOSED 22-25.9 .9 11-12.9 1.6 10-13.9 1.2 1.3 INSULATED dD @ 26-29.9 .7 13-1B.9 1.5 14-20.9 .7 .7 30-37.9 .6 19-25.9 1.1 21 &Un .4 .3 3B & Un .4 26-29.9 .6 1nR.IJn d 6A.14 FLOOR WINTER POINT MULTIPLIERS IWPM\ SLAB-oN-GRADE RAISED RAISED WOO[)2 '> POST OR PIER STEM WALL wi UNDER EDGE INSULATION CONCRETE '> CONSTRUCTION FLOOR INSULATION ADJACENT R-VALUE WPM R.VALUE WPM +i R-VALUE WPM WPM WPM 0-2.9 1"2'-51 0-2.9 4.0 '> 0-6.9 7.9 I.B 5.3 3-4.9 '":r:'f 3-4.9 1.B .... 7-10.9 2.1 .7 2.1 5-6.9 -2.4 !.~. 5-6.9 1.1 '> 11-1 B.9 1.5 .5 1.B 7 R.II;;- -')7 ;,\" 7 R.lln A 1aR. IIn Q <I 1 n WPM) 6A.15 INFILTRATION WINTER POINT MULTIPLIERS (WPM) 6A-16 DUCT MULTIPLIERS (oMl INFILTRATION PRACTICE WPM RETURN DUCTS RETURN DUCTS ISEE TABLE 6A-21\ R-VALUE IN UNCONDITIONED SPACE IN CONDITIONED SPACE PRACTICE #1 6.2 SUPPLY DUCTS IN 4.2-5.9 1.14 1.10 PRACTICE #2 (4.11 UNCONDITIONED SPACE 6.0-6.6 n.l0) 1.07 ?') 6.7 & Un 1.09 1.06 SUPPLY DUCTS IN 4.2-5.9 1.10 1.00 CONDITIONED SPACE' 6.0-6.6 1.07 - 1.00 f'. 7 R. IIn 1M 1M 6A.17 HEATING SYSTEM MULTIPLIERS IHSMl SYSTEM TYPE HEATING SYSTEM Mill TlPLlERSLH~ Central Heat --'::!SPF 6.40-6.79 6.80-6.89 /1t90-7.39"' 7.40-7.Blt_ _1~0-8,~L --..!l,1Q:!!.~m ~ ~"~-~.~~-- __~A:~.~~_ Pump Units HSM .53 .50 .49 J -:46-- .43 .41 __ I-------'~- _~2__ HSPF 9.90-10.39 10.4O-10.B9 10.90-11.39 11.40-11.B9 11.90-12.39 __J2.40 & up __ t-----oo HSM .34 .33 .31 .30 .29 .2B PTHP COP 2.50-2.69 2.70-2.B9 2.90-3.09 3.10-3.29 3.30-3.49 3.50-3.69 __ t---ll]-~~ ~-_4JL HSM .40 .37 .34 .32 .30 .29 .27 ---_.......1L~_ Electric Strio 1.0 Gas & LP Gas 1.0 (See Table 6A-1B for Credit Multiplier) MINIMUMS: CENTRAL UNITS-AIR SOURCE SPLIT SYSTEM 6.8 HSPF, SINGLE PKG. 6.6 HSPF. WATER SOURCE 3.8 COP. GROUND WATER SOURCE 3.4 COP, PTHP SEE TABLES 6.6 TO 6-8. 1 FOR MULTIPLIERS FOR OTHER TYPES OF CONCRETE BLOCK CONSTRUCTION SEE SECTION 2.1 OF APPENDIX C. 2 MULTIPLIERS FOR OTHER TYPES OF RAISED WOOD ASSEMBLIES SEE SECTION 3.1 OF APPENDIX C. 3 DUCTS IN CONDITIONED SPACE NEED TO BE INSULATED ONL YTO THE R-VALUE NECESSARYTO PREVENT CONDENSATION. -5- ADDITIONAL TABLES CLIMATE ZONES 4 5 6 6A-18 HEATING CREDIT MULTIPLIERS (HCM) SYSTEM TYPE HEATING CREDIT MULTIPLIERS iliCM) Allie Radiant Barrier HCM .98 ------,.-.------ ... Multizone HCM .95 --,,- Natural Gas AFUE .68-.72 .73-.77 .78-.82 .83-.87_ ~:~ I---'~~ ~ LJP HCM .61 .56 .53 .50 .47 .44 __m____...__ LPGll!: HCM .77 .72 .67 .63 .60 .57 6A-19 COOLING CREDIT MULTIPLIERS CCM) SYSTEM TYPE COOLING CREDIT MULTIPLIERS (CCM) ____.______n.___-.-_ Ceilina Fans r.86*) Cross Ventilation ~~* 'Credit may be taken for only Whole House Fan .95' one of Ihese system types concurrently. Multizone .95 Allie Radiant Barrier .95 Heat Recovery Unit LWATfR.cREDII ULD~UERSlI:fWCM)___.._____... Air Condiliooer_JieatPJ.llD,O_____ ~~_.3,5&UIL.... ---29_ __~2S____ ...4,(}:4,9... ..._5.Q &-.U.p______ .2.1~.._._ J 7.. A HWM MUST BE USED IN CONJUNCTION WITH All HWCM. SEE TABLE 6A-9. EF MEANS ENERGY FACTOR. Dedicated Heat Pump Solar 6A-21 "INAL TRA TION REDUCTION PRACTICE COMPLIANCE CHECKLIST (SEE SEcnON 606) COMPONENTS SECTION REQUIREMENTS FOR EACH PRACTICE CHECK PRACTICE #1 606.1 COMPLY WITH All INFll TRA TION PRESCRIPTIVES. Windows Maximum of 0.34 CFM oer linear foot of ooerable sash crack iincludes slidina alass doors): Exterior & Adiacent Doors Maximum of 0.5 CFM per sa. ft. of door area' solid core wood oanel insulated or alass doors only. Exterior Joints & Cracks To be caulked aasketed weatherstripped or otherwise sealed. PRACTICE #2 606.1 COMPLY WITH #1 AND THE FOllOWING: Exterior Walls and Floors Too olate oenetrations sealed. Infiltration barrier installed. Sole olatelfloor ioint caulked or sealed. Exterior Walls & Ceilinas Penetrations ioints and cracks on interior surface caulked sealed or aasketed. Ductwork Ductwork in unconditioned soace must be sealed. Fireolaces Eauiooed with outside combustion air doors. and flue dampers. Exhaust Fans Eauiooed with damoers. Combustion devices see 606.1.A.2 PRACTICE #3 606.1 COMPLY WITH PRACTICES #1 AND #2 AND THE FOLLOWING: Ceilinns Infiltration barrier installed. Interior Walls Too nenetrations sealed or ioints & cracks on interior walls caulked sealed or aasketed. Recessed Liahts Sealed from conditioned & insulated from ventilated attic spaces. Ductwork All ductwork located in conditioned soace. Combustion Appliances Be in unconditioned space (except direct vent), draw air from unconditioned space, exhaust by-products to outside. Combustion cooking appliances see section 606. 1.A.3 'I . I .' ij 6A-22 OTHER PRESCRIPTIVE MEASURES (must be met or exceeded bv all residences.) COMPONENTS SECTION REQUIREMENTS < , CHECK Water Heaters 612.1 Comply with efficiency requirements in Table 6-11. Switch or clearly marked circuit breaker (electric) or cutoff (aas) must be orovided. External or built-in heat trao reauired. Swimming Pools & Spas 612.1 Spas & heated pools must have covers (except solar heated). Non-commercial pools must have a pump timer. Gas spa & pool heaters must have a minimum thermal efficiency of 78%. Shower Heads 612.1 Water flow must be restricted to no more than 3 aallons Der minute at 80 PSIG. Air Distribution System 610.1 All ducts, fittings, mechanical equipment and plenum chambers shall be mechanically attached, sealed, insulated, and installed in accordance with the criteria of Section 610. Ducts in unconditioned attics must be insulated to a minimum of R-6. Air handlers shall not be installed in attics unless in mechanical closet. HVAC Controls 607.1 Separate readily accessible manual or automatic thermostat for each system. Insulation 604.1, 602.1 Ceilinas-Min. R-19. Common walls-Frame R-ll orCBS R-3 both sides. Common ceilina & floors R-ll. -6-