HomeMy WebLinkAbout96-6093
pO
-3()'
1fRt-
BUILDING PERMIT
N~
Perm it
CITY OF ZEPHYRHILLS
(813) 788.6611
- 609313
Date
y-/IJ- 7'-6
3 d..-!:> -. trD
BUILDING
....,5- f7 ~-o
ELECTRICAL
--.5'3,":iJ7;
PLUMBING
<..S? t> - tJ7)
MECHANICAL
Sewer Conn lJ..>tf'; tJv .
Water Conn: .3-!,,?/' tn::J
Water Meter: / b~....- t7v
T.I.F.'s:!f ~,(J7) I J. J-9-6
Pm.arty Owne' ~ r/v!7:~~ .
Job Address: ---5:.s '/0 - -
Parcell.D. # JI - at, -01.-/ - 00/0- /1" IJ [) - tJ /3 C;
Zoning: En:2de: ~adoll~ ~:J-
Desc,;pt;on of Wo" "-f!.' ".::r ""'" fl' j7 e ~ '? . ~
if1-f-/0'Wf!A. ~ ~~ <j"-,UJ ..7C, /1." /t
\31 ~'r...,>e,,- ~Li' A"ft r' II -.J 7- '9' A:, I' (:) : ~ b J1. flt FINAL
NO OCCUPAN'CY BEFORE C. .
Complete Plans, Specifications and Fee Must Accompany Application.
All work shall be performed in accordance with City Codes and Ordinances.
z--g-9
DATE
!:J -:2-7
c.o.
DATE
Inspector
Valuation or ~
Contract Price ,:S ,fJ9!J, ~
Permit Fee
City License Registration # ,;;.R-'(
State Certified License#
Telephone#
BUILDING
ELECTRICAL
AL74r19/
PLUMBING
/~ o2oh
MECHANICAL
~JjJ/, ?~.~
i!~hY\ el.9/
Tp. Servo _ SLB (j'- J d. - ~&; -Cq(3
Rough In!LO'-,Z.q-'P~-BI/.,L Tub Set ~/I:l- Z t:f~ tjJ~_6Ja
Meter Can 9-/o~9'.6 Water
Const. Pole t;-z..o-9~ e~f3 Sewer 1/....z..'Zr-t(j; 6P1
Pool Final
Pre-Meter 1/-d1-96go!3
Final
Ftr.
Pre SLB
Lintel q -d 7,
FRM. (o",?- ';'f?,
Insul. CL
WL ICJ ",Zq- fI~ ~ t..J,-
Breakers
Ducts Insl. 70-:?tf, 9~&/.t~
Compressor
Final
Driveway
~~~C-8AfJ IJ-.2.1-i'c,15otJ
REINSPECTION FEES: When extra inspection trips are necessary due to anyone of the following reasons, a
charge of Fifteen and 00/100 Dollars ($15.00) shall be made for each trip for each trade:
Vd& ~~~/ 9~/tJ-Y-6
pi /62. -3 -? L...
Wrong Address
Condemned work resulting from faulty construction.
Repairs or corrections not made when inspection called.
Work not ready for inspection when called.
Permit not posted on job site.
Plans not at job site.
Work not accessible.
a.
b.
C.
d.
e.
f.
g.
The payment of inspection fees shall be made before any further permits will be issued to the person owning
same,
BUILDER: BILL POE CONST.
ADDRESS: 5540 12TH STREET
OWNER:
sa. FT. PRICE
LMNG OR MAIN AREA:~ 980 I $ 35.00 ~
OTHER AREA UNDER ROOF:~ 72 ~ $ 11.00 ~
SLAB FOR FUTUREJ 418 I $ 11.00 I
SQUARE FEET UNDER ROOF:I 1,032 J
VALUATION:( $ 38,990.00 ~
ADDRESS:l $ 20.00 ~
DRIVEWAY:( $ 20.00 ~
FEES: l $ 210.00 ~
BLDG. PLUMB. ELEC. MECH.
PERMIT FEEs:1 $ 325.00 ~ $ 55.00 I $ 57.00 ~ $30.00
3/4" 1" 2"
WATER METER SIZEt $ X 165.00 I $ 245.00 I $ 610.00 I $ 840.00 I
SEWER WATER METER
CONNECTION FEES:( $ 1,278.00 ~ $ 350.00 I $ 185.00 (
RADON GAS:( $
PERMIT FEES: ~ $
CONNECTION FEES:~ $
WATER METER: I $
10.321
467.00 (
1,828.00 (
185.00 (
TRANSPORTATION IMPACT FEES:
99%
1%
$ 1,480.00
$ 1,485.20
$ 14.80
CREDIT:( $ 30.00 ~
SUB-TOTAL I $ 3,750.32 I
IRRIGATION METERl $ 165.00 ~
TOTALI $ 3,915.321
APPLICATION FOR PERKIT
CITY OF ZEPHYRHILLS
BUILDING DEPARTMENT
O~.
. \t7
~~ 3 (\~.H
( ~ \' ftl(fY
PHONE 7ro B- ? S-(, J
Z~4i1j.1J.s / 4~<k J 75)'/
OWNER'S NAME_C /'ivJ., {+J ('W~, b-iWf-e--fJ--
OWNER'S ADDRESS s'1lJ /~ /h~c-yt p~
JOB ADDRESS 0~-'70...J2,,~ 5~~
LEGAL DESCRIPTION: LOT(S) ) ~ if) I.' BLOCK) I /.e? SUBDIVISION 2-#1'6 C"
PARCEL LD.,-LJ- Z-~ - 21 -00'0 -Uc:,Ou- oJ:.!#) (OBTAIN FROM PROPERTY TAX NOTICE)
WORK PRoPOSED:4ew Construction _Addition _Alteration ~epair _Install
_Sign
----"ove
_Deaolish
PROPOSED USE: XSingle Faaily
_KIF _, of Units _K/H
_ec-ercial
_Indust. _Swia. Pool _Other
_Restaurant & Health Departaent Approval
DESCRIPTIO" OF WORK: S,~I"" Pp-.;1 JZu.;~
BUILDING SIZE: ~x ~~ . ji>1v Square Feet, tg I fJi-k
RESIDENTIAL:
COMMERCIAL :
ATTACH (2) PLOT PLANS & (2) SETS OF BUILDING PLANS & (1) SET ENERGY FORMS.
ATTACH (3) SETS OF BUILDING PLANS & (1) SET ENERGY FORMS.
PROPERTY SURVEY REQUIRED FOR ALL NEW CONSTRUCTION.
PERKITS REOUESTED
~UlLDING
X ELEC'flUCAL
bCHAlfiCAL
XPLUMB~NG .
$ 5 1/~OD--
} ')"0
Valuation of Total Construction
AMP Service ~ Florida Power Corp.
W.R.E.C.
$
J..,o ~ D ..--
Valuation of Mechanical Installation
GAS
ROOFING
SPECIALTY
TYPE OF CONSTRUC'fION: XBlock _Fr_e _Steel
Other
FINISHED FLOOR ELEVATIONS:
FT.
IS PROJEct IN FLOOD ZONE AREA? ~
YES NO
******************************************
,mma ~
Signature
/
F.T.RC'flUCIAN COMPANY p~~ rU~l.. I
;.:: ~ U4 ~ --<.:: State Cert. or Regist. t BlZo."2-1'~ I hI!!!!!. oo/S?>!..
ur . :A--- ~ City License Registration f 2-'1 J
******************************************
PLUMBER
~ -?~/^ I 21_ COIlPAIfY .......} pl- '
-- l LlY:>'t-L~~Stat-;'cert. or Regist. t e... 0
_ '~1License Registration t
,. ******************************************
o
Signature -"'J
MECHANICAL
Signature X
~ J COHPAIfY ",.., '> t2J.~-f
State Cert. or Regist. ,
49 ' City License Registration'
, . *~*** ****************************
lKJi)bJ
OTRRR COMPANY
State Cert. or Regist. t
Signature City License Registration ,
******************************************
APPLICATION APPROVED BY PERKIT OFFICER.
CONDITIONS OF PERMIT AFFIDAVIT
A. ,NOTICE OF DEED RESTRICTIONS
The undersigned under~tands that this perlit lay be subject to .deed restrictions. which aay be aore restrictive than City
regulations. fhe undersigned assUles responsibility for cOlpliance with any applicable deed restrictions.
B. UNLICENSED CONTRACTORS AND CONTRACTOR RESPONSIBILITIES
If the owner has hired a contractor or contractors to undertake work, they lay be required to be licensed in accordance with
state and local regulations. If the contractor is not licensed as required by law, both the owner and contractor aay be
cited for a lisdeaeanor violation under state law. If the owner or intended contractor are uncertain as to what licensing
requireaents aay apply for the intended work, they are advised to contact the City of Zephyrhills Building Departlent, (813)
788-6611.
Furtheraore, if the owner has hired a contractor or contractors, he is advised to have the contractor(s) sign portions of the
.Contractor Sections. of this application for which they will be responsible. If you, as the owner sign as the contractor,
you are indicating that you, rather than the contractor, are responsible for the work. If the contractor wishes you to sign
as contractor that lay be an indication that he is not properly licensed and is not entitled to peraitting privileges in the
City of Zephyrhills.
C. TRANSPORTATION IMPACT FEES AND UTILITY CONNECTION FEES
D. CONSTRUCTION LIEN LAW (CHAPTER 713, FLORIDA STATUTES, AS'AMENDED)
I certify that I, the applicant, have been provided with a copy of .Florida's Construction Lien Law - H08l!OWIler's Protection
Guide" prepared by the Florida Departtent of Agriculture and Consuaer Affairs. If the applicant is sOlleOne other than the
.owner", I certify that I have obtained a copy of the above described docuaent and proaise in good faith to deliver it to the
"owner" prior to cOlleDceaent.
E. CONTRACTOR'S/OWNER'S AFFIDAVIT
I certify that all the inforlation in this application is accurate and that all work will be done in coapliance with all
applicable laws regulating construction, zoning, and land develo~ent.
Application is hereby aade to obtain a perlit to do work and installation as indicated. I certify that no work or
installation has COIIenced prior to issuance of a perlit and that all work will be perforaed to aeet standards of all laws
regulating construction, City codes, zoning regulations, and land developaent regulations in the jurisdiction. I also
certify that I understand that the regulations of other governaental agenCies aay apply to the intended work, and that it is
IY responsibility to identify what actions I lust take to be in cOlpliance. Such agencies include but are not liaited to:
· Departlent of Knvironaental Regulation - Cypress Bayheads, Vetland Areas and Environaentally Sensitive Lands,
Water/Vastewater Treatlent
· Southwest Florida Water Hanageaent District - VeIls, Cypress Bayheads, Wetland Areas, Altering Watercourses
· ArlY Corps of Engineers - Seawalls, Docks, Navigable Waterways
t Departtent of Health & Rehabilitative Services, EnvirODJeDtal Health Unit - Wells, Wastewater freatJent, Septic Tanks
· OS EnvirODlental Protection Agency - Asbestos abateaent
I also certify that, if fill aaterial is to be used in Flood ZOne "AI or "A,etc.", it is understood that a drainage plan
addressing a .cQlPBDsating volDle" will be subaitted which is prepared by a professional engineer registered in the State of
Florida prior to perlit issuance.
A perlit issued shall be construed to be a license to proceed with the work and not as authority to violate, cancel alter, or
set aside any provisions of the technical codes, nor shall issuance of a perlit prevent the Building Official froa thereafter
requiring a correction of errors in plans, construction, or violations of any code. Every perlit issued shall beCOle invalid
unless the work authorized by such perlit is CQIIBDced within six aonths of issuance, or if work authorized by the perlit is
suspended or abandoned for a period of six IOnths after the tiae the work is coaenced. One 90 day extension of tile, lily be
allowed for the perlit with fee charge of $15.00. The extension shall be requested in writing to the Building Official. An
approved inspection lUst be logged during each six aonth period, or the project will be considered abandoned.
WARHING TO OWNER: YOUR FAILURE TO RECORD A NOrICE OF C<lDlBNCEMBNf HAY RESULT IN YOUR PAYING WICE FOR IHPRDVEHEITS TO YOUR
PROPERTY. IF YOU INfBHD TO OBTAIN FINANCING, CONSULT WIm YOUR LBHDER OR AN AftORNEY BEFORE RECORDING YOUR IIO'UCE OF
COHHENClHENf. JOBS UIf ,500 III VALUE DO NOT NEED 1'0 RECORD AND POST A "NOTICE OF IICEMBIf" .
SIGN~:
srATK OF FLORIDA
coum OF VA-5C 0
The foregoing instrum~t was acknowledged
before me this c!:27 tI.ay, 19~ by
STATE OF FLORIDA "u
COUIffY OF :s CD
The foregoing instrument was acknowledged
before me this .:27 kj , 19 7'~ by
who is personally known to me or who has
produced :PO()()-Qa"-';;l.-3:U- 0
as identification and who did/did not
take ~~~ c. Ak~
(Signature) 1-/ 1-
1~4-:!.fI(lee'1. A ~ . en fC-
(Name Typed, Printed or Stamped)
NOTARY PUBLIC
who is personally known to me or who has
produced '1>000- <1'3' -':;2-3;l.t --c)
as identification and who did/did no~
take an~~ a,,~
(SignaturE7v If / 4 I I. L
t<..aTTl eel\. . ne-11 ~
(Name Typed, Printed or Stamped)
NOTARY PUBLIC
KATHLEEN A. HENK
Notary Public. Slate of Florida
My Comm Expires July 5. 1998
No. CC 376761
Bonded Thru Wffldal Nlltary ~l'rIrla
KATHLEEN A. HENK
Notary Pubiic, Slate of Florida
My Comm, Expires July 5. 1998
No. CC 376761
Bonded Thru WI! Ids\ Notary >)HlJi rt
. 08-15-1996 04:00PM
Ff=;:i]r'l D C JCiHt-,j~:;m,~ AS$cIC I at.e:;
L'~.:~~_>~ ~:'.~ ~~~~'~~,~ ~~~ ~~ ~ :=,:.='. ~':: _~ ~_.,~~ ~_::~~ ~ '-: ; '_ '__ 4-
~
~ Q
<....) e-
~ .~ ($> l.Jl)
;- 7 a--
->"- '-'i" C\.....
~ ,~)'.:.~.~-
cii.:? to
1\, "\ '\ '.,
" "
r - - .- - --. - - - _. - -.' ,. "
~---~-<-<
! f t,-,
I ' .,:, .;,; !'::"if ,1
tJ!!:J.::.'7~l,e~: '
r~," '1
""'
,~
'~~
~......
.......
I
I
I
I
l.!
~~\
1', \\
I 'I
I( )i
\U'
~ '
'VI
I'
I
I
,,_i_l
1"-!,/3 :
I Lf',Q r
~/ "
8
iJ
i \ fr
I \ II
"'-J ~
k
v
--S<~
'7'-' (\
~ -
D
,~- ---~.=... ."_.=
TIJ
/
I
(' 151 72~5
F'. '01 .
2
<Ii
--JI
oj
o
<t
.~~~
1-: :rl
~"'~'r
:~
II
.:::
~
-::::::..
~
tre
IP [,,](c] ,p[E,f~:;::; II rQJ U\liffi\ IL
ilol)[~m(GJ[i,,:] IFJIRIW1]
TOWS-aN-ROGERS-
ENGINEERING INC.
ENGINEERING, PLANNING, ENVIRONMENTAL PERMIITING
August 23, 1996
Mr. Bill Poe
P.O. Box 465
Trilby, FL 33593
RE: Proposed Garrett Residence
12th Street
Dear Mr. Poe:
I have reviewed the topography of the subject site. I recommend that the building slab
be constructed at elevation 102.5 based on the attached sketch. You need to be sure that
the area is graded around the slab and to the east to ensure that runoff will not be
directed onto the adjacent lots.
If you should have any additional questions or concerns, please do not hesitate to
contact me at (813) 788-0400.
Sincerely,
Q#-"L ~
Stuart M. Rogers, P.E.
T owson- Rogers Engineering
---
SMR/ nkt
poe
5514 7TH STREET · ZEPHYRHILLS, FLORIDA 33540 813-788-0400
~v
~ ~
~ ta
~\ ~
~
&8 g
I
& 1'0.. -
~ -
....
a <.J
-.J ~
0
1-
k
~
to:
!:!
&U
.
B
~
~
:i
":o.~",
-
lC:-l1 ~ ~ . . . $ ~
~ ~~ I tI'" $.11 J \Vf.~.l " 9: 'Vi,
"', ~ 'II i:~111 W~ lilG 1-
" (,~Q ~"/I~., ~:61' d'
" ",ri.i'r~'. rJ' ~ Fs"-'L
"- "~~ri"li a/~ ~ ~
." ". Oi/~~ ~ (
~.J..G"tt;
-$' (,j .;;: 4' ~
~ "-'~
cf
"
"if
'11~
~
"/ ..~
.
~
,if
..Jlcf
~
~
~
~
..: ~
~ ~
,
,I"
#
1/
4'
~ ...
~ ~
. ..
~ ~
~
I~
( M WM
- N. 25000'00. W. 6O.00(O&F)
~
...
/2 the STREET
60' PLA TTED R/W 23." ASPHALT
Ito.OO(PJ 119."'CFI
........;.l'f ~/IV~,~
Department of Co~~unitY Affairs - FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION
FORM 600A-93 Residential Whole Building Performance Method A CENTRAL 4 5 6
PROJECT NAME:
AND ADDRESS:
BUILDER: I 0"'<.."
PERMITTING j CLIMATE ~D D
OFFICE: z,-1f/f7ra rJ/~ J:L,; ZONE: 4 ~ 5 6
PERMITNO.~ JURISDICTION NO.: ~
Please T CK
OWNER: J /
. I~'"
1. New construction or addition
2. Single family detached or Multifamily attached
3. If Multifamily-No. of units covered by this submission
4. If Multifamily, is this a worst case (yes / no)
5. Conditioned floor area (sq. ft.)
6. Predominant eave overhang (ft.)
7. Porch overhang length (ft.)
8. Glass type and area:
a. Clear glass
b, Tint, film or solar screen
9. Floor type and insulation:
a, Slab on grade (R-value + perimeter)
b. Wood, raised (R-value + sq. ft.)
c. Concrete, raised (R-value)
10. Net Wall type, area and insulation:
a. Exterior: 1. Concrete block (Insulation R-value)
2. Wood frame (Insulation R-value)
3. Steel frame (Insulation R-value)
4. Log (Insulation R-value)
b. Adjacent: 1. Concrete block (Insulation R-value)
2. Wood frame (Insulation R-value)
3. Steel frame (Insulation R-value)
4. Log (Insulation R-value)
11. Ceiling type, area and insulation:
a. Under attic (Insulation R-value)
b. Single assembly (Insulation R-value)
12. Air distribution system:
a. Ducts (Insulation + Location)
b. Air Handler( Insulation + Location)
13. Cooling system:
(Types: central-split, central-single pkg" room unit, PTAC., none)
14. Heating system:
(Types: heat pump, elec. strip, nat. gas, L.P, gas, room or PTAC, none)
15. Hot water system:
(Types: elec., natural gas, solar, L.P. gas, none)
16. Hot Water Credits:
a. Heat Recovery (HR)
b. Dedicated Heat Pump(DHP)
17. Infiltration practice: 1, 2 or 3
18. HV AC Credits (Type in Letter designation: CF-Ceiling Fan, CV-Cross vent,
HF-Whole house fan, RS-Attic radiant barrier, MZ-Multizone)
19. EPI (must not exceed 100 points)
a, Total As-Built points
b. Total Base points
EPI = Total As-Sui" points X 100
Total Base points
s covered by the calculation are in compliance with the
OWNER AGENT:
-1-
12a.
12b.
13a.
13b.
13c.
14a.
14b.
14c.
15a.
15b.
16a.
16b.
17.
18.
119.
19a.
19b.
DATE:
1. A!<M.)
2. 5>lVrj(f (
3.
4.
5. 7~ 0
6. I :,.~
7. if
Single Pane
8a. sq. ft.
8b. / 50. f.:. sq. ft.
sq. ft.
ft.
ft.
Double Pane
sq. ft.
sq. ft.
9a. R= 0
9b. R=
9c. R=
/:J. ~ I. ft.
sq. ft.
sq. ft.
7 c;,; sq. ft.
sq. ft.
sq. ft.
sq. ft,
sq. ft.
sq. ft.
sq. ft.
sq. ft.
9~O sq. ft.
sq. ft.
10a-1 R= S-
10a-2 R=
10a-3 R=
10a-4 R=
10b-1 R=
10b-2 R=
10b-3 R=
10b-4 R=
11 a. R= .3 D
11b. R=
R= ~ , ~J Co\ ' (condJuncond,)
R= t{. J. ("" , e c~ ' (condJuncond.)
Type: (! ~ IV)' V.I r
SEE~E~COP: /o.~D
Capacity: r ~ ~ (.;-
Type: /~ ~'
HSPF/COP/AFUE: 7 ( 0
,
Capacity: ~ ~ ~o u
Type: If ( t!.-"r ,
EF: "CJ /
;)-
CVf
7' r; J ~
/~ l.J~,
ref II <;- .
SUMMER CALCULATIONS
GLASS 1 BASE I BASE GLASS -'- SINGL E-PANE DOUBLE-PANE
AREA x SUMMER = SUMMER AREA x SUMMER P OINT MUL T. OR SUMMER POINT MUL T.
PT. MUL T. POINTS CLEAR T1N'f CLEAR TIN'f
N /rAJa 82.2 I~/...-=:" N i& (P 51.0 51.5 47.8 43.5
NE 82.2 NE 77.2 76,6 71.7 63.4
E l:;n, ~ 82.2 4C7 <-J 9, E ItlO .d- 109.2 107,1 102.0 87.3
SE 82.2 SE 112.9 110,3 104.1 89.4
S ul.L/ 82.2 ~ p) c:., W S '-I I. LI 100.2 98.3 90,9 78.8
SW ,::;, J 82.2 ,;J( ,);l.., SW ,;l.. 112.9 110.3 104.1 89.4
W lf0 . lp 82.2 2, ~.~ I W 4~, tu 109.2 107.1 102.0 87.3
NW ..?, , .;l. 82.2 ,;;)1 ,;2.., NW :5,;;>- 77.2 76.6 71.7 63.4
en H' 82.2 H' 367.7 303.3 324.6 238.1
en
:5
CJ
.l COND
15 TX FLOOR
. AREA
.15 I Q&rl
T
1 TOTAL 1 BASE
i GLASS T- ADJUST.
AREA FACTOR
I Fjt) _1..# I ,I' / A
T
I BASE
x GLASS
T SUBTOTAL
yep::: I" I "
...
COMPONENT
DESCRIPTION
EXTERIOR
~ ADJACENT
~
.l BASE SUMMER I BASE
x POINT. MUL T. = SUMMER
POINTS
1.0 70'~
.7
AREA
7q~
[]] EXTERIOR
g ADJACENT
I qU. (p
T
195
4.8
1.6
T
I ADJUSTED
= GLASS
I BASE SP
I iln I:::L
COMPONENT
DESCRIPTION
AREA
-6
T
!C,-S-
II
I ~O' Lr' I
/..f.B
T
CJ UNDER ATTIC CJIf?O .6 ~ 'J{) (,.-T' 00 . I tJ F-., - 7 La
z OR SINGLE .6
~
ii:i ASSEMBLY
(,,) BASE CEILING AREA EQUALS FLOOR AREA DIRECTLY UNDER CEILING, AS-BUILT CEILING AREA EQUALS ACTUAL CEILING SQUARE FOOTAGE.
II:
o
o
....I
U.
INFILTRATION
TOTAL COMPONENT BASE SUMMER POINT~
COOLING BASE COOLING TOTAL BASE
SYSTEM x SUMMER =
SYSTEM MULTIPLIER POINTS
.37
HOT
WATER
SYSTEM
T
I I
T~Al COMPONENT AS-BUilT SUMMER POINTS
TOTAL
AS-BUILT
SUM. PTS.
AS-BUilT
HOT WATER
SYSTEM DESC.
AS-BUILT
HOT WATER
POINTS
& 9 d-:::>-
'H = HORIZONTAL GLASS (SKYLIGHTS)
'FOR GLASS WITH KNOWN SHADING COEFFICIENT, SEE SECTION 1.1 OF APPENDIX C, TINT MULTIPLIERS MAY BE
USED FOR GLASS WITH SOLAR SCREENS, FilM, OR TINT.
-2-
, ~ ..' -,"
. ADDITIONAL TABLES
CLIMATE ZONES 4 5 6
6A.18 HEATING CREDIT MULTIPLIERS tHCM)
SYSTEM TYPE HEATING CREDIT MULTIPLIERS (HCM)
Attic Radiant Barrier HCM .98
Multizone HCM .95
AFUE .68-.72 .73- .77 .78-.82 .83-.87 .88-.92 .93 & Up
Natural Gas HCM ,61 .56 .53 .50 .47 ,44
LP Gas HCM .77 .72 .67 .63 .60 .57
6A-19 COOLING CREDIT MULTIPLIERS CCM) I
SYSTEM TYPE COOLING CREDIT MULTIPLIERS tCCM)
Ceilino Fans .86*
Cross Ventilation .95* *Credit may be taken for only
Whole House Fan .95* one of these system types concurrently.
Multizone .95
Attic Radiant Barrier .95
Heat Recovery Unit
With
HW M
F
HWCM
EF
Dedicated Heat Pump
Solar
6A-21 INFILTRATION REDUCTION PRACTICE COMPLIANCE CHECKLIST tSEE SECTION 606\
COMPONENTS SECTION REQUIREMENTS FOR EACH PRACTICE CHECK
PRACTICE #1 606.1 COMPLY WITH ALL INFILTRATION PRESCRIPTIVES.
Windows Maximum of 0.34 CFM per linear foot of operable sash crack (includes slidinQ glass doors).
Exterior & Adjacent Doors Maximum of 0.5 CFM per sa. ft. of door area; solid core, wood panel, insulated or Qlass doors onlv.
Exterior Joints & Cracks To be caulked Qasketed weatherstripped or otherwise sealed.
PRACTICE #2 606.1 COMPLY WITH #1 AND THE FOLLOWING:
Exterior Walls and Floors Top plate penetrations sealed. Infiltration barrier installed. Sole plate/floor ioint caulked or sealed.
Exterior Walls & Ceilinos Penetrations, joints and cracks on interior surface caulked, sealed or aasketed.
Ductwork Ductwork in unconditioned soace must be sealed.
Fireolaces Equipped with outside combustion air doors, and flue damoers.
Exhaust Fans Eauipped with dampers. Combustion devices see 606.1.A.2
PRACTICE #3 606,1 COMPLY WITH PRACTICES #1 AND #2 AND THE FOLLOWING:
Ceilinos Infiltration barrier installed.
Interior Walls 100 penetrations sealed or ioints & cracks on interior walls caulked sealed or aasketed.
Recessed Liohts Sealed from conditioned & insulated from ventilated attic soaces.
Ductwork All ductwork located in conditioned space.
Combustion Appliances Be in unconditioned space (except direct vent), draw air from unconditioned space, exhaust
by-products to outside. Combustion cooking appliances see section 606.1.A.3
6A-22 OTHER PRESCRIPTIVE MEASURES tmust be met or exceeded bv all residences.)
COMPONENTS SECTION REQUIREMENTS CHECK
Water Heaters 612.1 Comply with efficiency requirements in Table 6-11. Switch or clearly marked circuit breaker (electric)
or cutoff (aas) must be provided. External or built-in heat trap required.
Swimming Pools & Spas 612,1 Spas & heated pools must have covers (except solar heated). Non-commercial pools must have
a pump timer. Gas soa & 0001 heaters must have a minimum thermal efficiency of 78%,
Shower Heads 612.1 Water flow must be restricted to no more than 3 Qallons per minute at 80 PSIG.
Air Distribution System 610.1 All ducts, fittings, mechanical equipment and plenum chambers shall be mechanically attached,
sealed, insulated, and installed in accordance with the criteria of Section 61 O. Ducts in unconditioned
attics must be insulated to a minimum of R-6, Air handlers shall not be installed in attics unless in
mechanical closet.
HV AC Controls 607,1 Separate readily accessible manual or automatic thermostat for each system.
Insulation 604.1, 602.1 Ceilings-Min. R-19. Common walls-Frame R-11 or CBS R-3 both sides. Common ceilina & floors R-11.
-6-
N
NE
E
SE
S
SW
W
NW
lJ) H1
lJ)
:5
CJ
GLASS
AREA x
BASE
= WINTER
POINTS
'. .
CLIMATE ZONES 4 5 6 '
GLASS I SINGLE-PANE OR DOUBLE-PANE J WINTER lAS-BUILT
AREA x WINTER POINT MUL T. WINTER POINT MULT, x OVERHANG = GLASS
CLEAR T1Nf2 CLEAR TINf2 FACTOR (6A-10) WIN. PTS
N 10-,(' 9.6 9.6 5.6 6.1 1,05 1&7
NE 7.4 7.3 3.5 4.2
E (.pO r';>- ,2.2 - 2,0 - 5.6 ,3.6 ",,', I #Ja..
SE -10.3 - 9.7 -13.4 ,10.4
S i[),4 -10.9 -10.2 -14.0 -11.0 . '7.~ -Ltl.i<:
SW ~. ~ -10.3 - 9.7 -13.4 -10.4 ,4D -::2S;:;;
W ...A:'-',u - 2.2 - 2.0 - 5.6 - 3.6 ,")r 5.;z;
NW ~ .> 7.4 7.3 3.5 4.2 1./0 .;,;J. I 4
H1 -32.1 -28,0 -27.0 -21.5
WINTER CALCULAtioNS' ' '
.15 x
.15
BASE
AREA x = WINTER
POINTS
1.1 .~
1.8
,.
'10, ~ 5.1 ..;;l D '7 I I
4.0
,.
COMPONENT
DESCRIPTION
,.
AS-BUILT
GLASS
SUBTOTAL
c;O
COMPONENT
DESCRIPTION
EXTERIOR
:::l ADJACENT
c:t
~
AREA
-,
-S. J
,.
'~Ol
rn EXTERIOR
g ADJACENT
t..;CJ . {"
CJ UNDER ATTIC ~&(J .6 ~ 7; A q 1_l"'J 'LP ~',L..
:z OR SINGLE .6
:::i
W ASSEMBLY .6
to) BASE CEILING AREA EQUALS FLOOR AREA DIRECTLY UNDER CEILING, AS-BUILT CEILING AREA EQUALS ACTUAL CEILING SQUARE FOOTAGE,
,.
a:
o
o
....I
u..
,.
-1.9
- ,2
FOR SLAB ON GRADE USE PERIMETER LENGTH AROUND CONDITIONED FLOOR. FOR RAISED FLOORS USE AREA OVER UNCONDITIONED SPACE.
,.
INFILTRATION
4.1
TOTAL COMPONENT BASE WINTER POINT~
BASE HEATING TOTAL BASE
HEATING SYSTEM WINTER =
SYSTEM MULTIPLIER POINTS
1.1
....I
c:t
I-
o
I-
'FOR GLASS WITH KNOWN SHADING COEFFICIENT, SEE SECTION 1.1 OF APPENDIX C. TINT MULTIPLIERS MAY BE
USED FOR GLASS WITH SOLAR SCREENS, FILM, OR TINT.
-4-
..... .,
SUMMER POINT MULTIPLIERS (SPM)
CLIMATE ZONES 4 5 6
6A.1 SUMMER OVERHANG FACTORS (SO :'\ FOR SINGLE AND DOUBLE PANE GLASS.
~r OH RATIO .00-.11 .12-.17 .18-.26 .27-.35 .36-.46 .47-.57 .58-.70 .71-.83 .84-1.18 1.19-1.72 1.73-2.73 2,74+
N 1.00 .94 .91 .87 .83 .79 .75 .72 .69 .62 .56 .50
NElNW 1.00 .94 .91 .85 .79 .72 .68 .63 .58 .50 .40 .36
I-a: E!W 1.00 .95 .92 .85 .78 .70 .64 .58 .5~~ .42 .33 .26
fdo
~l SE/SW 1.00 .93 .90 .81 .72 .62 .55 .49 .4~~ .33 .27 .22
S 1.00 .91 .87 .n .67 .57 .50 .45 .39 .32 .28 .25
* Oft 1 ft 11j,ft ?ft ~ft ---w:ft .41j,ft <;1j,ft 1;1J,ft Q1J,ft lift ?Oft..
'To select bv Oyerhano Lennth no Mrt of class shall be more than 8 ft. below the ovem..nn.
6A-2 WALL SUMMER POINT MULTIPLIERS SPM
FRAME
WOOD
EXT ADJ
6.4 2.2
2.3 .8
1.9 .7
1.7 .6
1.0 .3
.6 .2
R-VALUE
0-6.9
7-10.9
11-12.9
13-18.9
19-25.9
26& U
STEEL
EXT ADJ
8.9 2.9
4.1 1.3
3.0 1.0
2.8 0.9
2.4 0.8
1.3 0.4
CONCRETE BLOCK'
INT, INSULATION
NORMAL WT.
EXT ADJ
2.5 .9
1.4 .7
1.0 .6
.8 .4
.4 .3
.2 .2
.1 .1
6A-3 DOOR SUMMER POINT MULTIPLIERS
DOOR TYPE EXTERIOR ADJACENT
WOOD 7.2 2.4
INSULATED 4.8 1.6
SPM)
6A-4 CEILING SUMMER POINT MULTIPLIERS ISPM\
UNDER ATTIC SINGLE ASSEMBLY CONCRETE DECK ROOF
R.VALUE SPM R.VALUE SPM CEILING TYPE
19-21.9 1.1 10-10.9 3.0 R.VALUE DROPPED EXPOSED
22-25.9 .9 11-12.9 2.7 10-13.9 3.0 3.3
26-29.9 .7 13-18.9 2.4 14-20.9 2.0 2.1
30-37.9 .6 19-25.9 1.8 21 & Uo 1.4 1.3
38 & Uo .4 26-29.9 1.1
MR.lln OQ
RAISED WOOI)2
POST OR PIER STEM WALL wi UNDER
CONSTRUCTION FLOOR INSULATION
SPM SPM
0.9 -5.8
-1.1 -2.8
-1.0 -2.2
ADJ~CENT
SPM
5.3
2.1
1.8
6A-6 INFILTRATION SUMMER POINT MULTIPLIERS (SPM)
6A-7 DUCT MULTIPLIERS IDM\
INFILTRATION PRACTICE SPM RETURN DUCTS RETURN DUCTS
ISEE TABLE 6A-21\ R-VALUE IN UNCONDITIONED SPACE IN CONDITIONED SPACE
PRACTICE #1 13.8 SUPPLY DUCTS IN 4.2-5.9 1.14 1.10
PRACTICE #2 10.9 6.0-6.6 1.10 1.07
7f'. UNCONDITIONED SPACE 6.7 & Uo 1.09 1.06
SUPPLY DUCTS IN 4,2-5.9 1.10 1.00
CONDITIONED SPACE' 6.0-6.6 1.07 1.00
~lln 1M 1M
6A-lI COOLING SYSTEM MULTIPLIERS ICSM\
SYSTEM TYPE COOLING SYSTEM MULTIPLIERS ICSM\
Central Units (SEER) Ratino 7.5-7.9 8.0-8.4 8.5-8.8 8.9-9.4 9.5-9.9 10.0-10.4 10.5-10,9 11.0-11.4 11.5-11.9 12.0-12.4
CSM .45 .43 .40 .38 .36 .34 .32 .31 .30 .28
PTAC & Room Units (EER) Ratina 12.5-12.9 13.0-13.4 13.5-13.9 14.0-14.4 14.5-14.9 15.0-15.4 15,5-15.9 16.0-16,4 16.5-16.9 17.0-17.4 17.5 & Un
CSM .27 .26 .25 .24 ,24 .23 .22 .21 .21 .20 .19
MINIMUMS: CENTRAL UNITS-AIR COOLED SPLIT SYSTEM 10,0 SEER, SINGLE PKG, 9.7 SEER, GROUND WATER HEAT PUMP 11.0 EER. PTAG-SEE TABLE 6-2
6A-9 HOT WATER MULTIPLIERS IHWM\
SYSTEM TYPE HOT WATER MULTIPLIERS IHWM
Electric Resistance EF .80-.81 .82-.83 .84-.85 .86-.87 .88-.90 .91-.93 .94-.96 .97 & Un
HWM 3879 3785 3695 3609 3527 3411 3302 3200
Natural Gas EF .43- .47 .48-.49 .50-.51 .52-.53 .54-.55 .56-.57 .58-.59 .60-.61 .62-.63 .64-.65 .66 & Un
HWM 2974 2664 2558 2459 2368 2284 2205 2132 2063 1998 1938
LP Gas HWM 3638 3259 3129 3009 2897 2794 2697 2607 2523 2444 2370
1 FOR MULTIPLIERS FOR OTHER TYPES OF CONCRETE BLOCK CONSTRUCTION SEE SECTION 2.1 OF APPENDIX C. 2 MULTIPLIERS FOR OTHER TYPES OF RAISED WOOD ASSEMBLIES SEE
SECTION 3,1 OF APPENDIX C, 3 DUCTS IN CONDITIONED SPACE NEED TO BE INSULATED ONLY TO THE R-VALUE NECESSARY TO PREVENT CONDENSATION.
-3-
WINTER POINT MULTIPLIERS (WPM)
CLIMATE ZONES 4 5 6
6A.10 WINTER OVERHANG FACTORS /WOFl
J OH RATIO 1 .00-.11 I .12-.17 1 .18-.26 .27-.35 1 .36-.46 I .47-.57 .58-.70 1 .71-.83 I .84-1.18 1.19-1,7211.73-2.73 I 2.74+
SINGLE PANE GLASS
N 1.00 1.03 1.05 1.08 1.10 1.13 1.15 1.18 1.20 1.24 1.29 1.34
NE/NW 1.00 1.07 1.10 1,15 1.20 1.25 1.30 1.35 1.39 1.50 1.59 1.67
E/W 1.00 .71 .57 .19 -,20 -.65 ,1.05 -1.48 -2.03 -3.01 -4.06 -5.04
SE/SW 1,00 .93 ,90 .80 .68 .54 .39 .22 .05 -.33 -.71 -1.01
l- S 1.00 .95 .92 .83 .70 .54 .36 .13 -.13 -.70 -.98 -1.09
(.)11:
~[ DOUBLE PANE GLASS
N 1.00 1,05 1.07 1.11 1.14 1.18 1.21 1.24 1.28 1.34 1.40 1,47
NE/NW 1.00 1.11 1.16 1.24 1.32 1.41 1.48 1.56 1.63 1.80 1.94 2.08
E/W 1.00 .88 .82 .66 .50 .31 .15 -,03 -.26 '.66 -1.10 -1.50
SE/SW 1.00 .95 .92 .85 .76 .65 .54 .41 .28 -.01 -.30 -.52
S 1.00 .96 .94 .87 .78 ,65 .51 .33 .13 -,30 -.51 -.60
OH LENGTH' Oft. 1 ft. 1%ft. 2ft. 3ft. 3% ft. 4'12 ft. 5'12 ft. 6% ft. 9% ft. 14ft. 20ft.+
'TO SELECT BY OVERHANG LENGTH, NO PART OF GLASS SHALL BE MORE THAN 8 FT. BELOW THE OVERHANG,
6A-11 WALL WINTER POINT MULTIPLIERS WPM
FRAME
WOOD
EXT ADJ
6.8 5.3
2.5 2.1
2.0 1.8
1.8 1,6
1.1 1.0
.7 .7
R-V ALUE
0-6.9
7-10.9
11-12.9
13-18.9
19-25.9
26&U
STEEL
EXT ADJ
9.4 6.7
4.4 3.3
3,3 2.6
3,0 2,4
2,6 2,2
1.4 1.2
CONCRETE BLOCK1
INT. INSULATION
NORMAL WT.
EXT ADJ
6.0 3.1
3.8 2.3
2.9 1.9
2.3 1.5
1.5 1.1
.8 .7
.5 .5
6A-12 DOOR WINTER POINT MULTIPLIERS 6A-13 CEILING WINTER POINT MULTIPLIERS (WPM)
DOOR TYPE EXTERIOR ADJACENT UNDER ATTIC SINGLE ASSEMBLY CONCRETE DECK ROOF
R-V ALUE WPM R-V ALUE WPM CEILING TYPE
WOOD 7.6 5.9 19-21.9 1.0 10-10.9 1.8 R-V ALUE DROPPED EXPOSED
22-25.9 .9 11-12.9 1.6 10-13.9 1.2 1.3
INSULATED 5.1 4.0 26-29.9 .7 13-18.9 1,5 14-20.9 .7 .7
30,37.9 .6 19-25.9 1.1 21 & Uo .4 .3
38 & Uo .4 26-29.9 .6
'lnR. Iln .4
6A-14 FLOOR WINTER POINT MULTIPLIERS (WPMl
SLAB-ON-GRADE T RAISED UU. RAISED WOO[)2
EDGE INSULATION T. CONCRETE POST OR PIER STEM WALL wI UNDER ADJACENT
Y CONSTRUCTION FLOOR INSULATION
R-VALUE WPM R-VALUE WPM R-VALUE WPM WPM WPM
0-2.9 2.5 I 0-2.9 4.0 0-6.9 7.9 1.8 5.3
3-4.9 -1.7 3-4.9 1.8 in.. 7-10.9 2.1 .7 2,1
5-6.9 -2.4 5-6.9 1.1 11-18.9 1.5 .5 1.8
7 R. Iln -:?7 7 !I. Un II UU Hl!l.Un Q --, 1 n
WPM)
6A-15 INFILTRATION WINTER POINT MULTIPLIERS (WPM)
6A-16 DUCT MULTIPLIERS IOMl
INFILTRATION PRACTICE WPM RETURN DUCTS RETURN DUCTS
ISEE TABLE 6A-21l R-V ALUE IN UNCONDITIONED SPACE IN CONDITIONED SPACE
PRACTICE #1 6.2 SUPPLY DUCTS IN 4,2-5.9 1.14 1.10
PRACTICE #2 4.1 6.0-6.6 1.10 1.07
-9 ? UNCONDITIONED SPACE 6.7 & UP 1.09 1.06
SUPPLY DUCTS IN 4.2-5.9 1.10 1.00
CONDITIONED SPACE' 6.0-6.6 1.07 1.00
R 7 !l.lln 1 nR 1 nn
6A-17 HEATING SYSTEM MULTIPLIERS IHSM\
SYSTEM TYPE HEATING SYSTEM MULTIPLIERS (HSM\
Central Heat HSPF 6.40-6.79 6.80-6.89 6.90-7.39 7.40-7.89 7.90-8.39 8.40-8.89 8.9-9.39 9.4-9.89
Pump Units HSM .53 .50 .49 .46 .43 ,41 .38 .36
HSPF 9.90-10.39 10.40-10.89 10.90-11.39 11.40-11.89 11.90-12,39 12.40 & un
HSM .34 .33 .31 ,30 .29 .28
PTHP COP 2.50-2.69 2.70-2,89 2.90-3.09 3.10-3.29 3.30-3.49 3.50-3.69 3.70-3.89 3.90-4.19
HSM .40 .37 .34 .32 .30 .29 .27 .26
Electric Strio 1.0
Gas & LP Gas 1.0 (See Table 6A-18 for Credit Multiolier)
. MINIMUMS: CENTRAL UNITS-AIR SOURCE SPLIT SYSTEM 6,8 HSPF, SINGLE PKG, 6.6 HSPF, WATER SOURCE 3,8 COP, GROUND WATER SOURCE 3.4 COP, PTHP SEE TABLES 6-6 TO 6-8.
1 FOR MULTIPLIERS FOR OTHER TYPES OF CONCRETE BLOCK CONSTRUCTION SEE SECTION 2.1 OF APPENDIX C. 2 MULTIPLIERS FOR OTHER TYPES OF RAISED WOOD ASSEMBLIES SEE
SECTION 3.1 OF APPENDIX C. 3 DUCTS IN CONDITIONED SPACE NEED TO BE INSULATED ONLY TO THE R-VALUE NECESSARY TO PREVENT CONDENSATION.
-5.
CONTRACTOR #: 008194
NAME: WILLIAM RPOE
ADDR: 21125 TRILBY CEMETARY RD
C/ST: TRILBY FL33525
C E N T R ALP E R M I T TIN G
PASCO COUNTY, FLORIDA
DATE: 12/03/96
PAGE: 1 OF 1
ISSUE OFFICE: D
RECEIPT NUMBR: 00304666
OFFICE: DADE CITY
FOR:
CHECK # CASH
CONTRACTOR: 008194 11-26-21-0010-11600-0130 CITY Z/HILLS
TOTAL AMOUNT: 3.97
ACCNT COMPNY ACCOUNT CENTER AMOUNT DESCRIPTION/PERMT DATA DRICR
114 B450 - 363000 - 2 3.97 ****** SOLID WASTE FEE 60
RECEIVED BY
DESCRIPTION: LOT'S 15 AND 16, BLOCK 116, CITY OF ZEPHYRHIlLS,
ACCORDING TO THE MAP OR PLAT 71-f€REOF', AS RECORDED
IN PlAT BOOK I, PAGE 54, PUBLIC RECORDS OF' PASCO COUNTY, flORIDA.
:\ \1
.....0
\,~r)
\ 6co. (fJ\.
\
. ~.
or;JiifJ
..\ of) . . ,.
{'o V'
?/\
'/
.;J~..p/ /". I \ ,/
y.' -../ e 101. ~ \/IJ'tJ1
/ ~ ~ ~
(( \/ V .... A/(''\ A N
.~ ,.-/~, \
\ . /" '\o-tl'- IL'(, \
.'t / t \0
\~ \ ,/" AIY'~.;Y'
\~ \ ~~.~'-(V' ~Ol//'/
~, ,/~.
~. . /p ."
\ \ /" / ~':t~
'~
~,
~
. ~o
o(fJ'ifJ
~o G'J
. f."""
\;i: ..
.,.&l'\OI
-?
""
'\
~
~~
l'
'"t ~
"= '\
~\\
\ ~
. ..
\
Jl'4. FJ.P, .l.
NODII g
SOtrTHWESTrRL 'f CORN(R Of
BlOCI(' 116.
t:';<\ ST\\..lCr Ho~6'
F.P\.., EL. IOZ,.CjD
...... oor
CI"fO<D QIl1'(
BILL POE
GARRElT RESIDENCE
:Al~.WL CAD~
\
\
\
-z.
.
~.
...
'0
(}J :....\
~ ,-~
0/
,.-/ .'0
,/"~ ~ :.-\
())
0:
.f
tD
T
;.0-
~
~
~ (jJt\,?Jr)
\~o
:\ \4-
.....0
/60. _
~o
-........ _~~<; ~1e,TH,l~. ...~uND
cLevbi10N
or
SHEl:T
81S-7~