HomeMy WebLinkAbout96-6258
:;l i};-,ffl)
BUILDING
BUILDING PERMIT NO'
CITY OF ZEPHYRHILLS Permit.
(813) 788-6611
~:? .SO
PLUMBING
- 6258~.
) ;-/J7'- Y,b
Date
d '-9.-..Sa
ELECTRICAL
3-.5': t'V
MECHANICAL
Sewer Conn /,:L 7&tfD
Water Conn: ~--o .IJV
P"'perty Owne" ~
Job Address: c3 7 ~- ~ ~
Parcell.D. # 3 jI-.:;s--;l/- &l'JhtJ - 003cJCJ ~ 0 tJy-u
Zon;n9' 'A~ Radon Ga" ij """
~ ~~~ l
Description of Work t I ~.
~.rP~3.-.:J6-Y'7~j/!~~~~ :2~v-o >1Y1-1
NO OCCUPANCY BEFORE C.O.
Wate~Meter: /~~
T.I.F. s: l:Lo 'II
,
~
FINAL
-4, /- Cf7
DATE
Complete Plans, Specifications and Fee Must Accompany Application. C.O.
All work shall be performed in accordance with City Codes and Ordinances.
DATE
Inspector
Permit Fee
Signature
Company
Address
Telephone#
~~
Valuation or
Contract Price
J-b.!J6 tJ~ cTD
r
City License Registration # e2 3..S
State Certified License#
_~~~ .O"AJ
BUILDING
V1~ ~ rl>, J 13,'/
ELECTRICAL
'--:1?//4'r ./S-Y/
PLUMBING
4~/l-~ /9c2/
MECHANICAL
Tp. Servo
Rough In) ..jl>- '7'1 6~l3
Meter Can J / - /T- .9~
Const. Pole
Pool
Pre-Meter 3-diD-Q'" el..';t.
Final
SLB
Tub Set J-JO-cr']&LL
Water
Sewer /1-Zo~9~ G,Ll....
Final
Breakers
Ducts Insl. I-JD-r?iJ4itJ
Compressor
Final
Ftr.
Pre SLB
Lintel
FRM. 1-/0-'17 6,1..L.
Insul. CL
WL }-/1- ??;3o(J
Driveway
REINSPECTION FEES: When extra inspection trips are necessary due to anyone of the following reasons, a
charge of Fifteen and 00/100 Dollars ($15.001 shall be made for each trip for each trade:
a. Wrong Address -V~ ~~ J/-/F-7b
b. Condemned work resulting from faulty construction. ~
C. Repairs or corrections not made when inspection called. 1-/ - / - f 'J
d. Work not ready for inspection when called.
e. Permit not posted on job site.
f. Plans not at job site.
g. Work not accessible.
The payment of inspection fees shall be made before any further permits will be issued to the person owning
same.
APPLICATION FOR PERl-lIT
CITY OF ZEPHYRHILLS
BUILDING DEPARTMENT
INTERIOR COMPLETION
APPLICANT Sandy Develop~en~ ComQany. Inc.
ADDRESS 12303 u.S. Hwy 301. Dade City, FL 33525
PHONE (352) 567-7992
"
OWNER Oak Run Properties. Inc. 7335-2 Gall. Blvd.. Zephvrhills. FL 33541
JOB LOCATION 37759 Oak Run Cir (BLD 7)
LOT SIZE
x
AREA SQ. FT.
LEGAL DESCRIPTION: LOT(S)
BLOCK
SUBDIVISION
PARCEL 1. D. # 34-25-21-0000-00300-0080
. 7 WORK PROPOSED:-1l-New Construction ____Addition ____Alteration ____Repair ____Install
_Sign/Temp.
____Sign
____Move
_Demolish
~,
PROPOSED USE: _Single Family
_M/F
_# of Units
.~/H
_Commercial
_Indust.
____Swim. Pool
Other
_Restaurant & Health Department Approv~l
27 '33"X40'
. "'" ,
BUILDING SIZE: 15.3_111.. 40 .
1 ~qq
Square Feet,
Height
RESIDENTIAL:
COMMERCIAL :
ATTACH .(2) PLOT PLANS & (2) SETS OF BUILDING PLANS & (1) SET ENERGY FORMS.**
ATTACH (3) SETS OF BUILDING PLANS & (1) SET ENERGY FORMS.**
**COPY OF CONTRACT REQUIRED.
PERMITS REOUESTED
-1L-BUILDING
....LELECTRICAL
....LMECHANICAL
.lL..PLUMBING
$
Valuation of Total Construction
AMP Service
Florida Power Corp.
_W.R.E.C.
$
Valuation of Mechanica! tristallation
GAS
ROOFING
SPECIALTY
TYPE OF CONSTRUCTION: _Block _Frame ____Steel
Other
FINISHED FLOOR ELEVATIONS:
FT.
;"Q;.
€rSIos ::J::J 'ON 'UJUJO::J ."""
e6661 'ZI 'Po 'dX3 'UJUJOO ^VV \~.~.~.'.<<~~
P!JOI~ 10 a~e~s 'o!Jqnd ^Je~ON ~i..' '".r}.
N\tMS 31l\tl\tN <\:;:~o~
':".;...,~_:;.u-,,-~;~~
rrnos ::J::J 'ON 'wwO::J
666! 'Z! 'PO 'dX3 'wwO::J ^W
BP!JOI~ 10 ajelS 'o!Jqnd AlejON
N\fMS 31l\tl\fN
JIland AHtflON
(padwe~s ~o pa~u~~d 'padAl aweN)
J !land AHtflON
(padwe~s ~o pa~u~~d 'padAl aweN)
"4410'0 ue a>te4
e
.L{!l-eo ue a>te4
~ou 10' uot:l.e:Jt.Ll1"~P~ S'E'
p:.ra"pu...ld
~l?1.( g"fr1 ..10. aw o~ UMou:1 A IIeuos~ad s~ OL{M
~d .('0() 3f'IWoaqr.
(a..1n~eufl~s)
~-
(a_m:j.eufl~s)
~l!JIIj.lO..1C
3E'''f Q"ftt :10 aw ':):j. LlMow1 ^ II E'LlIJs~ad 5 ~ OL{M
~d '(Y1 3W~r'
. CONDITIoNS OF QS~MI~ AFF!DAV1T
A; . NOTICE OF DEED RESTRICTIONS
The undersigned understands that this per..it 'Iay be subject hI 'deed restricti.oni" Nhich ...y be '~rI restrictive than City
regulations. The undersigned aSIUDS re5~onsibility for co.pli,ince with any ilpplicable deed restrictions,
B. UNLICENSED CONTRACTORS AND CONTRACTOR RESPONSIBILITIES
If the owner has hired a contractor Dr contractors to undertake Nork, they lay be required to be licensed in accordance Nith
state and local regulations. If the cont'ractor i~ not licensed as required by lalt, both the ollner and contractor lay be
cited for a lisdeleanor violation under state law, If the ONner Dr intended contractor are uncertain as to Khat licensing
requirelents lay apply for the intended work, theV are advised .to contact the City of Zephyrhills Building Departlept, (813)
788-6611. . ,
Fur therlore , if the owner has hired a contractor Dr contractors, he is advised to have the contractor(s) sign portions of the
"Contractor Sections" of this application for which they will be responsible. If you, as the ONner sign as the contractor,
you are indicating that you, rather than .the contractor, are responsible for the Nork. If the contractor Nishes you to sign
as contractor 'that lay be an indication that he is not properly licensed and is not entitled to perlitting privileges in the
City of Zephyrhills.
C~ TRANSPORTATION IMPACT FEES AND UTILITY CONNECTION FEES
1
D~ CONSTRUCTION LIEN LA~ (CHAPTER 713, FLORIDA STATUTES, AS AMENDED)
I certify that I, the applicant, have been provided ltith a copy of "Florida's Construction Lien Law - HOleoNner's Protection
G~de. prepared by the Florida Departlent of Agriculture and Consuler Affairs,' If the applicant is sOleone other than the
"owner., I certify that I have Dbtained a CDPY Df the above described doculent and protise in good faith to deliver it to the
.Dwner' priDr to cOllencelent.
E. CONTRACTOR'S/OWNER'S AFFIDAVIT
I certify that all the inforlatiDn in this application is accurate and that all Hork will be done in co.pliance with all
applicable laNs regulating cDnstructiDn, zoning, and land developaent.
Application is hereby aade tQ obtain a perlit tD do Mork and installation as indicated. I certify that no Nork Dr
installatiDn has cDllenced priDr to issuance of a perlit and that all work will be perforled to leet standards of all laNS
regulating cDnstruction, City cDdes, zoning regulations, and land developlent regulations in the jurisdiction. I also
certify that I understand that the regulatiDns of other governlental agencies lay apply to the intended Nork, and that it is
IY responsibility tD identify what actiDns I lust take to be in cOlpliance. Such agencies include but are not lilited to:
f Deoartlent of Environlental Reoulation .- Cypress Bayheads, Wetland Areas and Environtentally SeQsitive Lands,
Water/Wastewater Treatlent
f SDuthwest FIDrida Water "anaaeaent District - Wells, Cypress Bayheads, Wetland Areas, .Altering Watercourses
f ArlY CDrDs Df Enaineers - Seawalls, Docks, Navigable Waterways
I Departlent of Health & Rehabilitative Services. .Environlental Health Unit - Wells, ~astewater Treatlent, Septic Tanks
f US EnvirDnlental ProtectiDn AGency - AsbestDs abatelent
I alSD certify that, if fill laterial is tD be used in Flood Zone "A" or "A,etc.", it is understood that a drainage plan
addressing a 'cDlpensating volule. will be sublit~ed Nhich is prepared by a professional engineer registered in the state of
FIDrida prior to perlit issuance. .
A perlit issued shall be construed tD be a license to proceed with the work and not as authority to violate, cancel alter, or
set aside any provisions of the technical codes, nDr shall issuance of a pertit prevent the Building Official frol thereafter
requiring a correction of errors in plans, construction, or violations of any code. Every perlit issued shall becole invalid
unless the work authDrized by such perlit is cOllenced within six tonths of issuance, Dr if work authorized by the pertit is
suspended or abandDned for a period of six IDnths after the tile the wDrk is cOlleneed. One 90 day extension of tite, tay be
alloNed for the perlit with fee charge of $15.00. The extension shall be requested in writing to the Building Official. An
approved inspection lust be IDgged during each six lonth period, or the project will be considered abandoned.
WARMIHS TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT KAY RESULT IN YOUR PAYING TWICE FOR IKPROVEMENTS TO YOUR
PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR lENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF
CD" EKEMT. JDBS UNDER $2,500 ALUE DO NOT NEED TO RECORD AND POST A "NOTICE OF COMMENCEMENT",
I
STATE OF flORIDA P
COUNTY OF A-5 c...o
The foregoing instrument was acknowledged
before me this~, 19~ by
STATE OF FLORIDA
COUNTY OF PASCo
The foregoing instrument
befc'l-e me this Dc.t-(4
was acknowledged
, 19~ by
BUILDER: Sandy Development
ADDRESS: 37759 Oak Run Dr.
OWNER
SQ. FT. PRICE
LIVING OR MAIN AREA:~ 1,328 I $ 20.00 I
OTHER AREA UNDER ROOF:[ 0 I $ 11.00 I
o rHER:1 0 , $ 11.00 I
SOUARE FEET UNDER ROOF:~ 1,328 I
VALUATION:l $ 26,560.00 ,
ADDRESS:~ $ 20.00 ,
DRIVEWAy:J $ 20.00 I
FEES: l $ 150.00 I
BLDG. PLUMB. ELEC. MECH.
PERMIT FEES:( $ 265.00 I $ 62.50 ~ $ 59.50 I $35.00
3/4" 1" 2"
WATER METER SIZEI $ X 165.00 I $ 245.00 I $ 610.00 I $ 840.00 I
SEWER WATER METER
CONNECTION FEES:~ $ 1.278.00 I $ 350.00 I $ 165.00 l
RADON GAS:[ $
PERMIT FEES:~ $
CONNECTION FEES:~ $
WATER METER' $
- I
422.00 I
1,628.00 ,
165.00 I
TRANSPORTATION IMPACT FEES:
99%
1%
$ 1,204.00
$ 1,191.96
$ 12.04
CREDIT
CREDIT: I $
SUB-TOTALf $
- l
2,255.00 I-'It? dO
:J., J..../.j-: tTD
~
165.00 I
IRRIGATION METERI $
TOTAL I $
2,420.00 I
C:Oj\.ln:::f."'ICfCIF: :\1::
Nr-~t1E: ::::t1I'.IDY DE\/
(.'j[!DP ~ 12303 1...1 :::;
1.::: / :::; r: [I{.) 0 I::: C I TV
~ E N T R ALP E R M I T TIN G DATE:.: 04/01/97
PASCO COUNTY, FLORIDA PAGE: 1 OF 1
I :::;::;::UE OFF I CE : D
RECEIPT NUMBR: 00316830
301 OFFICE: DADE CITY
F' L. :::~ .::~~; :/ ~:i
FOr;::
et'-lEC!< # :~:::::'::;':I
CITY OF Z-HILLS PERMIT 6258
II il.
rOlPd.._ {iMOUNT:
COMPNY ACCOUNT CENTER
8450 - 363000 - _
:~::=:. 90
AMOUNT DESCRIPTION/PERMT DATA DRieR
38.90 ****** SOLID WASTE FEE AO
(.~ c: c~ !\~ or
:::,:FCE J. '-/ED
"""-
BY y--h_~_- __ ...
PASCO COUNTY, FLORIDA
Permit No.
~:2~-r
j/-- /Y-16
Date Permitted
Builder Name/Owner Name '~""J jJ ~~
County Parcel No. ~--..:;.s-.>> - (j &00 - '" -- _ 0 t!J d--O
Location J;7 ~ --J'- 9' tJ t!i ~ _ ~.uA--\.
ClassificationlType of Use ~./A~J~
Subd.
TRANSPORTATION IMPACT FEE CALCULATION
EXEMPT D
Rate $
Zone No.
Sq. Ft.lUnit
Prepared By
Impact Fee Amount $
The above impact fee has been established suant to the 0 County Transportation Impact Ordinance as adopted
by the Board of County Commissioners is amount is payable the issuance of a Certificate of Occupancy
or authority to utilize the permitted s cture.
RESOURCE RECOVERY ASSESSMENT
EXEMPT D
RESIDENTIAL
NONRESIDENTIAL
No. Units
/
Gross Sq. Ft. (GSF)
RatelERU - 52.00/Year
or $0. I 42/Day
ERU Assign No.
Assessment - (No. Units) x ($0.142)
x (No. Days)
Assessment -
(GSF) x (ERU) x (0.142) x (No. Days)
100
TOTAL FEE $
J~.qo
TOTAL FEE $
The above assessment has been established pursuant to the Pasco County Ordinance No. 89-07 and Resolution No. 89-197,
as commended.
THE ASSESSMENT WILL BE CALCULATED AT THE TIME OF ISSUANCE OF THE CERTIFICATE OF
OCCUPANCY.
NO CERTIFICATE OF OCCUPANCY OR FINAL POWER RELEASE WILL BE ISSUED UNTIL THE AMOUNTS LISTED
HAVE BEEN PAID AND RECEIPTED FOR BY A CENTRAL PERMITTING OFFICE OF PASCO COUNTY.
Acknowledgement below does not imply acceptance of concurrence, but simply receipt of a copy of this form, placing
the building permit owner on notice of this assessment and the conditions of payment for same.
Date
Received By
----.-----------------------------------------------------------------------------------------------------------------------------------------------
OFFICE USE ONLY
TRANSPORTATION REC. NO. - . DATE *J ~ ~ ~
RESOURCE RECOVERY REC. NO. 3/ {p c;(~ DATE fV' Jq? u' . -9-;[5
White
Applicant
Canary
Trans/Finance
Canary
RR/Finance
Pink
Office
Green
Bldgllnsp
feecal:ce
PC93113094/ A
Department of Community Affairs
FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION
FORM 600A-93 . A JIJe.$id~.PJ;~' al W , Ie Building Performance Method A
PROJECT NAME: uaJi f<~ ,-0 : BUILDER:
AND ADDRESS:3?7~-?&;;1 ~~ :PERMITTIN._uG~1. . Ilf ., :CLIMATE ,/,
'OFFICE:({~ 'ZONE: 41v, 5' I 61 1
OWNER: : PERMIT )(0. f; ~s~<:r-lJ 1 JURISDICTIONI.NO. t'7/{;,CJ()
CK
1. New Construction
2. Multi-Family
3. 1
case (yes/no) 4. No
5. 1080.00
6. 2.00
7. 0.00
Single Pane
8a.142.0sqft
8b. O.Osqft
1. New construction or addition
2. Single family detached or Multifamily attached
3. If Multifamily-No. of units
4. If Multifamily, is this a worst
5. Conditioned floor area (sq.ft.)
6. Predominant eave overhang (ft.)
7. Porch overhang length (ft.)
8. Glass area and type:
a. Clear Glass
b. Tint, film or solar screen
9. Floor type and insulation:
a. Slab on grade (R-value, perimeter)
10.Net Wall type area and insulation:
a. Exterior: 1. Concrete (Insulation R-value)
a. Exterior: 2. Wood frame (Insulation R-value)
11.Ceiling type area and insulation:
a. Under attic (Insulation R-value)
12.Air distribution systems
a. Ducts (Insulation + Location)
13.Cooling system
14.Heating System:
15.Hot water system:
16.Hot Water Credits: (RR-Heat Recovery,
DHP-Dedicated Heat Pump)
17.Infiltration practice: 1, 2 or 3
18.HVAC Credits (CF-Ceiling Fan, CV-Cross vent,
HF-Whole house fan, RB-Attic radiant
barrier, MZ-Multizone)
19.EPI (must not exceed 100 points)
a. Total As-Built points
b. Total Base points
SN: 2334
CENTRAL
Double Pane
O.OOsqft
O.OOsqft
9a.R= 0.00 , 134.00 ft
10a-1 R= 4.20, 864.00sqft____
10a-2 R=11.00, 640.00sqft____
11a.R=30.00 , 1080.00sqft____
12a. R= 6.00, uncond
13. Type: Central A/C
SEER: 10.00
14. Type: Heat Pump
HSPF: 7.00
15. Type: Electric
EF: 0.89
16.
17.
18.
2
19.
19a.
19b.
85.44
18992.67
22228.91
-------------------------------------------------------------------------------
--------------------------------------------------------------.-----------------
I Hereby certify that the plans and
specifications covered by this calcu-
lation are in compliance with the
Florida Energy Code. n__~
PREPARED RY: ~ ~
DATE: - _
I Review of the plans and specifications
covered by this calculation indicates
compliance with the Florida Energy
Code. Before construction is completed
this building will be inspected for
compliance in accordance with Section
553.908 F.S.
I hereby certify that this building is
in compliance with the Florida Energy
Code.
OWNER/AGENT:
DATE:
BUILDING
DATE:
, .
*******************************************************************************
SUMMER CALCULATIONS
*******************************************************************************
=== BASE ===
=== AS-BUILT ===
GLASS----------------
ORIEN AREA x BSPM =
-------------------------------------------------------------------------------
-------------------------------------------------------------------------------
I
I
POINTS :
TYPE
SC
ORIEN
AREA
x SPM
x SOF
= POINTS
-------------------------------------------------------------------------------
N 62.00 82.2 5096.4 SGL CLR N 20.0 51.0 .84 860.2
SGL CLR N 42.0 51.0 .82 1762.3
S 80.00 82.2 6576.0 SGL CLR S 20.0 100.2 .70 1409.5
SGL CLR S 20.0 100.2 .70 1409.5
SGL CLR S 20.0 100.2 .85 1698.9
SGL CLR S 20.0 100.2 .85 1698.9
-------------------------------------------------------------------------------
.15 x CONDo FLOOR / TOTAL GLASS = ADJ. x GLASS =
AREA AREA FACTOR POINTS
ADJ GLASS
POINTS
GLASS
POINTS
-------------------------------------------------------------------------------
.15
1,080.00
142.00
1.141
11,672.40
13,316.40 :
8,839.33
NON GLASS------------ :
AREA x BSPM = POINTS: TYPE
-------------------------------------------------------------------------------
-------------------------------------------------------------------------------
R-VALUE
AREA x SPM = POINTS
WALLS----------------
Ext 1504.0 1.0 1504.0
-------------------------------------------------------------------------------
Ext Wood Frame
Ext Wood Frame
Ext NormWtBlock In
Ext NormWtBlock In
11. 0
11. 0
4.2
4.2
320.0
320.0
432.0
432.0
1. 90
1. 90
1.16
1.16
608.0
608.0
501.1
501.1
DooRS----------------
Ext 21.0 4.8 100.8
Ext Wood
21. 0
7.20
151. 2
CEILINGS-------------
VA 1080.0 .6 648.0
Under Attic
30.0 1080.0
.60
648.0
FLooRS---------------
SIb 134.0 -31.8 -4261.2
Slab-on-Grade
.0
134.0 -31.90 -4274.6
INFILTRATION---------
1080.0 10.9 11772.0
Practice #2
1080.0 10.90 11772.0
TOTAL SUMMER POINTS :
23,080.00 :
==============================================================:=================
TOTAL x
SUM PTS
===============================================================================
19,354.18
SYSTEM
MULT
=
COOLING : TOTAL
POINTS : COMPON
x CAP x DUCT x SYSTEM x CREDIT = COOLING
RATIO MULT MULT MULT POINTS
-------------------------------------------------------------------------------
23,080.00
.37
8,539.60 : 19,354.18 1.00 1.070
.340
1. 000
7,041. 05
===============================================================================
*******************************************************************************
WINTER CALCULATIONS
*******************************************************************************
=== BASE ===
=== AS-BUILT ===
GLASS----------------
ORIEN AREA x BWPM =
-------------------------------------------------------------------------------
-------------------------------------------------------------------------------
I
I
POINTS :
TYPE
SC
ORIEN
AREA
x WPM
x WOF
= POINTS
-------------------------------------------------------------------------------
N 62.00 -3.4 -210.8 SGL CLR N 20.0 9.6 1. 09 209.9
SGL CLR N 42.0 9.6 1.11 445.7
S 80.00 -3.4 -272.0 SGL CLR S 20.0 -10.9 .74 -162.0
SGL CLR S 20.0 -10.9 .74 -162.0
SGL CLR S 20.0 -10.9 .90 -196.2
SGL CLR S 20.0 -10.9 .90 -196.2
--------------------------------------------------------------.-----------------
.15 x CONDo FLOOR / TOTAL GLASS = ADJ. x
AREA AREA FACTOR
GLASS
POINTS
=
ADJ GLASS
POINTS
GLASS
POINTS
--------------------------------------------------------------.-----------------
.15
1,080.00
142.00
1.141
-482.80
-550.80 :
-60.85
NON GLASS------------ :
AREA x BWPM = POINTS: TYPE
===============================================================================
R-VALUE
AREA x WPM = POINTS
-------------------------------------------------------------------------------
WALLS----------------
Ext 1504.0 1.1 1654.4 Ext Wood Frame 11.0 320.0 2.00 640.0
Ext Wood Frame 11.0 320.0 2.00 640.0
Ext NormWtBlock In 4.2 432.0 3.26 1408.3
Ext NormWtBlock In 4.2 432.0 3.26 1408.3
DOORS----------------
Ext 21.0 5.1 107.1 f Ext Wood 21.0 7.60 159.6
CEILINGS-------------
UA 1080.0 .6 648.0 Under Attic 30.0 1080.0 .60 648.0
FLOORS---------------
SIb 134.0 -1.9 -254.6 Slab-on-Grade .0 134.0 2.50 335.0
INFILTRATION---------
1080.0 4.1 4428.0 Practice #2 1080.0 4.10 4428.0
-------------------------------------------------------------------------------
-------------------------------------------------------------------------------
I
I
6,032.10 :
9,606.39
TOTAL WINTER POINTS
TOTAL x
WIN PTS
-------------------------------------------------------------------------------
-------------------------------------------------------------------------------
SYSTEM
MULT
=
HEATING : TOTAL
PO I NTS : COMPON
x CAP x DUCT x SYSTEM x CREDIT = HEATING
RATIO MULT MULT MULT POINTS
-------------------------------------------------------------------------------
6,032.10 1.10
6,635.31: 9,606.39 1.00 1.070
.484
1. 000
4,974.96
-------------------------------------------------------------------------------
-------------------------------------------------------------------------------
. .
.*******************************************************************************
WATER HEATING
*******************************************************************************
=== BASE ===
=== AS-BUILT ===
NUM OF
BEDRMS
-------------------------------------------------------------------------------
-------------------------------------------------------------------------------
x
MULT
=
TOTAL
TANK VOLUME
EF
TANK
RATIO
x MULT x CREDIT
MULT
= TOTAL
-------------------------------------------------------------------------------
2
3527.0
7,054.00
40
.89
1.000
3488.3
1. 00
6,976.67
-------------------------------------------------------------------------------
-------------------------------------------------------------------------------
*******************************************************************************
SUMMARY
*******************************************************************************
=== BASE ===
=== AS-BUILT ===
COOLING
POINTS +
-------------------------------------------------------------------------------
-------------------------------------------------------------------------------
HEATING
POINTS
HOT WATER
+ POINTS =
TOTAL
POINTS
COOLING
POINTS +
HEATING
POINTS
HOT WATER
+ POINTS =
TOTAL
POINTS
-------------------------------------------------------------------------------
8539.6
6635.3
7054.0
22,228.91
7041.0
4975.0
6976.7
18,992.67
===============================================================================
*****************
* EPI = 85.44 *
*****************
For detailed information
of the EPI rating number
or for any ITEM listed,
ask your Builder for
DCA Form 600A-93
or Form 600B-93
ENERGY GUIDE
EPI= 85.4
o 10 20 30 40 50 60 70 80 90 100
:----------------------------------x------:
The maximum allowable EPI is 100. The lower the EPI the more efficient the home
RESIDENTIAL ENERGY PERFORMANCE RATING SHEET
ITEM
HOME VALUE
Low Efficiency
High Efficiency
WINDOWS............ ........ .Single Clear
SINGL CLR DBL TINT
:X----------------____:
INSULA T I ON. . . . . . . . . . . . . . . . . .
Ceiling
R-Value......... 30.0
R-I0 R-30
:--------------------X:
R-O R-7
:-----------X---------:
R-O R-19
:X-----------------___:
Wall
R-Value......... 4.2
Floor
R-Value. . . . . . . .. 0.0
AIR CONDITIONER.............
SEER. . . . . . . . . . . . . . . . . . . . " 10. 0
10.0 SEER 17.0
:X-----------------___:
HEATING SySTEM..............
Electric HSPF............ 7.0
6.8
HSPF
12.0
:x----------------____:
WATER HEATER................
Solar
EF . . . . . . . . . . . . . .
0.88 0.96
:--X---------------___:
0.54 0.90
'---------------______1
I ,
0.40 0.80
Electric EF.............. 0.89
Gas EF. . . . . . . . . . . . " 0.00
---------------------
OTHER FEATURES..............
....... .....................................
I certify that these energy saving features required for the Florida
Energy Code have been installed in this house.
Address:
Builder
Signature:
Date:
City/Zip
Florida Energy Code for Building Construction - 1993
Florida Department of Community Affairs
FL-EPL CARD93
For detailed information
of the EPI rating number
or for any ITEM listed,
ask your Builder for
DCA Form 600A-93
or Form 600B-93
ENERGY GUIDE
EPI= 85.4
o 10 20 30 40 50 60 70 80 90 100
:----------------------------------x------:
The maximum allowable EPI is 100. The lower the EPI the more efficient the home
RESIDENTIAL ENERGY PERFORMANCE RATING SHEET
ITEM
HOME VALUE
Low Efficiency
High Efficiency
WINDOWS.................... .Single Clear
SINGL CLR DBL TINT
:X----------------____:
INSULA T I ON. . . . . . . . . . . . . . . . . .
Ceiling
R-Value......... 30.0
R-10 R-30
:--------------------X:
R-O R-7
:-----------X---------:
R-O R-19
:X------------------__:
Wall
R-Value......... 4.2
Floor
R-Value...... ... 0.0
AIR CONDITIONER. . . . . . . . . . . . .
SEER. . . . . . . . . . . . . . . . . . . . .. 1 0 . 0
10.0
SEER
17.0
:x-----------------___:
HEATING SySTEM..............
Electric HSPF........ .... 7.0
6.8 HSPF 12.0
:X-----------------___:
WATER HEATER................
Solar
EF . . . . . . . . . . . . . .
0.88 0.96
:--X-----------------_:
0.54 0.90
:---------------------:
0.40 0.80
:---------------------:
Electric EF.............. 0.89
Gas EF. . . . . . . . . . . . .. 0.00
OTHER FEATURES..............
........................... .
I certify that these energy saving features required for the Florida
Energy Code have been installed in this house.
Address:
Builder
Signature:
Date:
City/Zip
Florida Energy Code for Building Construction - 1993
Florida Department of Community Affairs
FL-EPL CARD93
SERIAL # 2334
* ResmanuJ(c) * 11-06-1996
WHOLE HOUSE
HEAT GAIN / HEAT LOSS CALCULATION USING FLA/RES(c) DATA FILES
(BASED ON A.C.C.A. MANUAL J - SEVENTH EDITION (c) 1986 by A.C.C.A.)
-------------------------------------------------------------------------------
PROJECT
ADDRESS :
CITY :
OWNER :
BLDG CONTR
HVAC CONTR
Cond FIr Area: 1080 SF * GLASS/SF RATIO = 13.1% * House Faces: South
* Climatic Conditions & Design Conditions *
----------------------------------------------------------------------------
Geographical Location : Florida Lakeland
------------------------------------ ---------------------------------------
North Latitude / Elevation
Outdoor Winter Dry Bulb
Indoor Winter Dry Bulb
Winter (Actual) Temp.Diff.
Winter Temp. Diff. (wTd)
Outdoor Summer Dry Bulb
Outdoor Summer Wet Bulb
Outdoor Summer Hum. Ratio Gr/Lb
Indoor Summer Relaltive Hum.
Indoor Summer Design Gr/Lb.
Indoor Summer Dry Bulb
Indoor Summer Wet Bulb
Summer Daily Range
Summer (Actual) Temp.Diff.
Summer (User Sel) Temp.Diff. (sTd)
28 Deg. / 214 Ft. Above Sea Level
41 Deg. F
70 Deg. F
29 Deg. F
40 Deg. F
91 Deg. F
76 Deg. F
113
50%
51
75 Deg. F
62.3 Deg. F @ 64 Gr/Lb
17 Deg. F M
16 Deg. F
20 Deg. F
----------------------------------------------------------------------------
* HEATING SUMMARY * MF2S108S.DAT * COOLING SUMMARY *
SUBTOTAL 24663.08 :STRUCTURE SENSIBLE 9273.76
'MECH.VENT- 0 Cfm 0.00
:SENS. + MECH.VENT 9273.76
: TEMP. SWING @ 3 DEG. 1. 00
: OCCUPANT/APPLIANCE 2400.00
DUCT LOSS 1233.15 :DUCT GAIN 1167.38
TOTAL LOSS/BTUH 25896.23 :TOTAL SENSIBLE 12841.14
:TOTAL LATENT 2671.37
:SENSIBLE + LATENT 15512.51
20% OVERSIZE FACTOR 5179.25 :20% SENS.OVRSZE FTR: 2568.23
ACTUAL + 20% OVERSIZE: 31075.48 :SENS. + 20% OVERSIZE: 15409.37
EQT MANUF GOODMAN
HTG INP/BTUH 27400
SENSIBLE BTUH 21000
TONAGE 2.4 (S)EER 10
NOTES:
* EQUIPMENT SELECTION *
CU MOD # CPE30-1
HTG OUTP/BTUH 27400
LATENT BTUH 7600
CLG CFM 1000
AHU MOD # AW30-05
AFUE/HSPF 6.8 TYPE HP
TTL CLG BTUH 28600
HTG CFM 1000
GLASS
* LOA D
C A L C U L A T ION *
S All Shaded
Type Shdg Sc OvHg Botm Hgt
S.C. R.S. 1 2 6 5
Area LossjBtuh
20.00 924.00
GainjBtuh
420.00
S All Shaded
-------------------------------------------------------------------------------
S.C. R.S. 1
2
6
5
20.00
924.00
420.00
N No Shd Fctr
-------------------------------------------------------------------------------
S.C. R.S. 1
2
6
n/a
20.00
924.00
420.00
N No Shd Fctr
-------------------------------------------------------------.------------------
S.C. R.S. 1
3
8
n/a
42.00
1940.40
882.00
S All Shaded
-------------------------------------------------------------------------------
S.C. R.S. 1
2
10
7.8
20.00
924.00
420.00
S All Shaded
-------------------------------------------------------------~------------------
S.C. R.S. 1
2
10
7.8
20.00
924.00
420.00
-------------------------------------------------------------------------------
Infiltration Winter Htm ( 27.26 )
Infiltration: Summer Htm ( 6.82 )
x
x
142.00
142.00
3870.92
968.44
R-Value Area LossjBtuh Gain/Btuh
W ALL S---------------_______________________________________________________
Wood Stud - Ext. 11 320.00 1152.00 672.00
Wood Stud - Ext. 11 320.00 1152.00 672.00
NjW C.B. - Int Insul - Ext. 4.2 432.00 2505.60 993.60
N/W C.B. - Int Insul - Ext. 4.2 432.00 2505.60 993.60
SUBTOTALS: 1504.00 7315.20 3331.20
D 0 0 R S----------------______________________________________________________
Solid Core/Wood - Ext. 0 21.00 598.50 228.90
Infiltration :Winter Htm( 27.26 ) x 21.00 572.46
Infiltration :Summer Htm( 6.82 ) x 21.00 143.22
SUBTOTALS: 21.00 1170.96 372.12
C ElL I N G S--------------__________________________________________________
Under Attic 30 1080.00 1404.00 1620.00
F L 0 0 R S---------------_____________________________________________________
Slab on Grade 0 134.00 Lin.Ft. 4341.60 000.00
-------------------------------------------------------------------------------
* TOTAL STRUCTURE SENSIBLE *
--------------------------------------------------------------'-----------------
24663.08
9273.76
Department of Community Affairs
FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION
FORM 600A-93 R~idential Whole Building Performance Method A
PROJECT NAME: Oo.-h. t<~'7?/\',()~.~- : BUI LDER:
AND ADDRESS:3?';>,s-"1 &~R~.....CM.~ :PERMITTING~~
: OFFICE: J
OWNER: : PERMIT NO.;;:;L ~(3
1. New construction or addition
2. Single family detached or Multifamily attached
3. If Multifamily-No. of units
4. If Multifamily, is this a worst case (yes/no)
5. Conditioned floor area (sq.ft.)
6. Predominant eave overhang (ft.)
7. Porch overhang length (ft.)
8. Glass area and type:
a. Clear Glass
b. Tint, film or solar screen
9. Floor type and insulation:
a. Slab on grade (R-value, perimeter)
10.Net Wall type area and insulation:
a. Exterior: 1. Concrete (Insulation R-value)
b. Adjacent: 2. Wood frame (Insulation R-value)
II.Ceiling type area and insulation:
a. Under attic (Insulation R-value)
12.Air distribution systems
a. Ducts (Insulation + Location)
13.Cooling system
14.Heating System:
15.Hot water system:
16.Hot Water Credits: (HR-Heat Recovery,
DHP-Dedicated Heat Pump)
17.Infiltration practice: 1, 2 or 3
18.HVAC Credits (CF-Ceiling Fan, CV-Cross vent,
HF-Whole house fan, RB-Attic radiant
barrier, MZ-Multizone)
19.EPI (must not exceed 100 points)
a. Total As-Built points
b. Total Base points
SN: 2334
CENTRAL
: CLIMATE
I ZONE. 4 I vr 5 I I 6 I I
: JURISDICTION I NO. b//6 ~V
CK
1.
2.
3.
4. No
5. 960.00
6. 2.00
7. 0.00
Single Pane
8a.l02.0sqft
8b. O.Osqft
New Construction
Multi-Family
1
Double Pane
O.OOsqft
O.OOsqft
9a.R= 0.00 , 128.00 ft
10a-l R= 4.20, 384.00sqft____
10b-2 R=11.00, 640.00sqft____
11a.R=30.00 , 960.00sqft____
12a. R= 6.00, uncond
13. Type: Central A/C
SEER: 10.00
14. Type: Strip Heat
COP: 1.00
15. Type: Electric
EF: 0.89
16.
17.
18.
2
19.
19a.
19b.
98.87
20135.06
20364.27
---------------------------------------
-------------------------------------------------------------------------------
---------------------------------------
I Hereby certify that the plans and
specifications covered by this calcu-
lation are in compliance with the
Florida Energy c~ .
PREPARED BY:
DATE: t;;
Review of the plans and specifications
covered by this calculation indicates
compliance with the Florida Energy
Code. Before construction is completed
this bUilding will be inspected for
compliance in accordance with Section
553.908 F.S.
BUILDIN~t~AL~/~ ~
DATE: 1" 7 iJ
I hereby certify that this building is
in compliance with the Florida Energy
Code.
OWNER/AGENT:
DATE:
***~***************************************************************************
SUMMER CALCULATIONS
*******************************************************************************
=== BASE ===
GLASS--------------__
ORIEN AREA x BSPM =
I
I
POINTS :
===============================================================================
=== AS-BUILT ===
TYPE
SC
ORIEN
AREA
x SPM
x SOF
= POINTS
N
5096.4
-------------------------------------------------------------------------------
62.00
82.2
S
40.00
82.2
3288.0
SGL CLR
SGL CLR
SGL CLR
SGL CLR
N
N
S
S
20.0
42.0
20.0
20.0
51. 0
51.0
100.2
100.2
.84
.82
.70
.70
860.2
1762.3
1409.5
1409.5
-------------------------------------------------------------------------------
.15 x CONDo FLOOR / TOTAL GLASS = ADJ. x
AREA AREA FACTOR
GLASS
POINTS
ADJ GLASS
POINTS
=
GLASS
POINTS
.15
102.00
-------------------------------------------------------------------------------
5,441.44
-------------------------------------------------------------------------------
--------------------------------------------------------------------------------
960.00
1.412
8,384.40
11,836.80 :
NON GLASS------------ :
AREA x BSPM = POINTS: TYPE
R-VALUE
AREA x SPM = POINTS
----------------------------- --------------------------------.-----------------
WALLS--------------__
Ext 384.0 1.0 384.0 Ext NormWtBlock In 4.2 192.0 1.16
Ext NormWtBlock In 4.2 192.0 1.16
Adj 640.0 .7 448.0 Adj Wood Frame 11. 0 320.0 .70
Adj Wood Frame 11.0 320.0 .70
DOORS--------------__
Ext 21.0 4.8 100.8
CEILINGS-------------
UA 960.0 .6 576.0
FLOORS-------------__
SIb 128.0 -31.8 -4070.4
INFILTRATION---------
960.0 10.9 10464.0
222.7
222.7
224.0
224.0
Ext Wood
21. 0
7.20
151. 2
Under Attic
30.0
960.0
.60
576.0
Slab-on-Grade
.0
128.0 -31.90 -4083.2
Practice #2
960.0 10.90 10464.0
-------------------------------------------------------------------------------
-------------------------------------------------------------------------------
TOTAL SUMMER POINTS
19,739.20 13,442.88
TOTAL x
SUM PTS
=
COOLING
POINTS
----------------------------- -------------------------------------------------
----------------------------- -------------------------------------------------
TOTAL
COMPON
x CAP x DUCT x SYSTEM x CREDIT = COOLING
RATIO MULT MULT MULT POINTS
SYSTEM
MULT
19,739.20
7,303.50
----------------------------- -------------------------------------------------
4,890.52
-------------------------------------------------------------------------------
-------------------------------------------------------------------------------
.37
13,442.88 1.00 1.070
.340
1. 000
***~~**************************************************************************
WINTER CALCULATIONS
*******************************************************************************
=== BASE === === AS-BUILT ===
GLASS----------------
ORIEN AREA x BWPM = POINTS
----------------------------- -------------------------------------------------
----------------------------- -------------------------------------------------
TYPE
SC ORIEN AREA x WPM x WOF = POINTS
----------------------------- -------------------------------------------------
N
62.00
-3.4
-210.8
SGL CLR
SGL CLR
SGL CLR
SGL CLR
N
N
S
S
20.0
42.0
20.0
20.0
9.6
9.6
-10.9
-10.9
1. 09
1.11
.74
.74
S
40.00
-3.4
-136.0
209.9
445.7
-162.0
-162.0
.15 x CONDo FLOOR / TOTAL GLASS = ADJ. x GLASS =
AREA AREA FACTOR POINTS
-------------------------------------------------------------------------------
ADJ GLASS
POINTS
GLASS
POINTS
.15
-489.60 :
-------------------------------------------------------------------------------
331.55
--------------------------------------------------------------.-----------------
-------------------------------------------------------------------------------
960.00
102.00
1. 412
-346.80
NON GLASS------------ :
AREA x BWPM = POINTS: TYPE
R-VALUE
AREA x WPM = POINTS
-------------------------------------------------------------------------------
WALLS----------------
Ext 384.0 1.1 422.4 Ext NormWtBlock In 4.2 192.0 3.26
Ext NormWtBlock In 4.2 192.0 3.26
Adj 640.0 1.8 1152.0 Adj Wood Frame 11.0 320.0 1.80
Adj Wood Frame 11.0 320.0 1.80
DOORS----------------
Ext 21.0 5.1 107.1
Ext Wood
21.0
7.60
CEILINGS-------------
UA 960.0 .6 576.0
Under Attic
30.0
960.0
.60
FLOORS---------------
SIb 128.0 -1.9 -243.2
Slab-on-Grade
.0
128.0
2.50
INFILTRATION---------
960.0 4.1 3936.0
Practice #2
960.0
4.10
-------------------------------------------------------------------------------
-------------------------------------------------------------------------------
3936.0
TOTAL WINTER POINTS
I
I
5,460.70 :
--------------------------------------------------------------'-----------------
--------------------------------------------------------------'-----------------
7,726.99
625.9
625.9
576.0
576.0
159.6
576.0
320.0
TOTAL x SYSTEM = HEATING: TOTAL x CAP x DUCT x SYSTEM x CREDIT = HEATING
WIN PTS MULT POINTS: COMPON RATIO MULT MULT MULT POINTS
5,460.70 1.10
1.000
--------------------------------------------------------------.-----------------
8,267.88
-------------------------------------------------------------------------------
-------------------------------------------------------------------------------
6,006.77: 7,726.99 1.00 1.070
1.000
****'***************************************************************************
WATER HEATING
*******************************************************************************
=== BASE ===
=== AS-BUILT ===
NUM OF
BEDRMS
===============================================================================
x
MULT
=
TOTAL
TANK VOLUME
EF
TANK
RATIO
x MULT x CREDIT
MULT
= TOTAL
-------------------------------------------------------------------------------
2
3527.0
7,054.00
40
.89
1.000
3488.3
1. 00
6,976.67
-------------------------------------------------------------'------------------
-------------------------------------------------------------'------------------
*******************************************************************************
SUMMARY
*******************************************************************************
=== BASE ===
=== AS-BUILT ===
COOLING
POINTS
-------------------------------------------------------------------------------
-------------------------------------------------------------------------------
+
HEATING
POINTS
HOT WATER
+ POINTS =
TOTAL
POINTS
COOLING
POINTS +
HEATING
POINTS
HOT WATER
+ POINTS =
TOTAL
POINTS
--------------------------------------------------------------------------------
7303.5
6006.8
7054.0
20,364.27
4890.5
8267.9
6976.7
20,135.06
-------------------------------------------------------------------------------
-------------------------------------------------------------------------------
*****************
* EPI = 98.87 *
*****************
For detailed information
of the EPI rating number
or for any ITEM listed,
ask your Builder for
DCA Form 600A-93
or Form 600B-93
ENERGY GUIDE
EPI= 98.9
:---------------------------------------x-~
The maximum allowable EPI is 100. The lower the EPI the more efficient the home
o 10 20 30 40 50 60 70 80 90 100
RESIDENTIAL ENERGY PERFORMANCE RATING SHEET
ITEM
HOME VALUE
Low Efficiency
High Efficiency
WINDOWS. . . . . . . . . . . . . . . . . . . . . Single Clear
SINGL CLR DBL TINT
:X------------------__:
INSULA T I ON. . . . . . . . . . . . . . . . . .
Ceiling
R-Value...... ... 30.0
R-10
R-30
Wall
R-Value......... 11.0
:--------------------x:
R-O R-7
:--------------------X:
R-O R-19
:X------------------__:
Floor
R-Value......... 0.0
AIR CONDITIONER.............
SEER. . . . . . . . . . . . . . . . . . . . " 10. 0
10.0
SEER
17.0
:x------------------__:
HEATING SySTEM..............
Electric COP............. 1.0
2.50
COP
4.19
:x-----------------___:
WATER HEATER................
Solar
EF. . . . . . . . . . . . . .
0.88 0.96
:--X----------------__:
0.54 0.90
I .
.---------------------,
0.40 0.80
Electric EF.............. 0.89
Gas EF. . . . . . . . . . . . " 0.00
---------------------
OTHER FEATURES..............
. . . . . . . . . . . . . . . . . . . . . . . . . . . .
I certify that these energy saving features required for the Florida
Energy Code have been installed in this house.
Address:
Builder
Signature:
Date:
City/Zip
Florida Energy Code for Building Construction - 1993
Florida Department of Community Affairs
FL-EPL CARD93
For'detailed information
of the EPI rating number
or for any ITEM listed,
ask your Builder for
DCA Form 600A-93
or Form 600B-93
ENERGY GUIDE
EPI= 98.9
:---------------------------------------x-:
The maximum allowable EPI is 100. The lower the EPI the more efficient the home
o 10 20 30 40 50 60 70 80 90 100
RESIDENTIAL ENERGY PERFORMANCE RATING SHEET
ITEM
HOME VALUE
Low Efficiency
High Efficiency
WINDOWS. . . . . . . . . . . . . . . . . . . . . Single Clear
SINGL CLR
DBL TINT
:x-------------------_:
INSULATION. . . . . . . . . . . . . . . . . .
Ceiling
R-Value......... 30.0
R-10 R-30
:--------------------X:
R-O R-7
:--------------------X:
R-O R-19
:X-------------------_:
Wall
R-Value. ........ 11.0
Floor
R-Value......... 0.0
AIR CONDITIONER. . . . . . . . . . . . .
SEER. . . . . . . . . . . . . . . . . . . . .. 1 0 . 0
10.0
SEER
17.0
:x------------------__:
HEATING SySTEM..............
Electric COP............. 1.0
2.50 COP 4.19
:X-------------------_:
WATER HEATER............ ....
Electric EF.... .......... 0.89
0.88
0.96
Solar
EF. . . . . . . . . . . . . .
:--x------------------:
0.54 0.90
:---------------------:
0.40 0.80
Gas EF. . . . . . . . . . . . .. 0.00
---------------------
OTHER FEATURES..............
. . . . . . . . . . . . . . . . . . . . . . . . . . . .
I certify that these energy saving features required for the Florida
Energy Code have been installed in this house.
Address:
Builder
Signature:
Date:
City/Zip
Florida Energy Code for Building Construction - 1993
Florida Department of Community Affairs
FL-EPL CARD93
SERIAL # 2334
* ResmanuJ(c) * 11-06-1996
WHOLE HOUSE
HEAT GAIN / HEAT LOSS CALCULATION USING FLA/RES(c) DATA FILES
(BASED ON A.C.C.A. MANUAL J - SEVENTH EDITION (c) 1986 by A.C.C.A.)
-------------------------------------------------------------------------------
PROJECT
ADDRESS :
CITY :
OWNER :
BLDG CONTR
HVAC CONTR
Cond FIr Area: 960 SF * GLASS/SF RATIO = 10.6% * House Faces: South
* Climatic Conditions & Design Conditions *
Geographical Location : Florida
----------------------------------------------------------------------------
Lakeland
-------------------------------------------------------------~---------------
North Latitude / Elevation
Outdoor Winter Dry Bulb
Indoor Winter Dry Bulb
Winter (Actual) Temp.Diff.
Winter Temp. Diff. (wTd)
Outdoor Summer Dry Bulb
Outdoor Summer Wet Bulb
Outdoor Summer Hum. Ratio Gr/Lb
Indoor Summer Relaltive Hum.
Indoor Summer Design Gr/Lb.
Indoor Summer Dry Bulb
Indoor Summer Wet Bulb
Summer Daily Range
Summer (Actual) Temp.Diff.
Summer (User Sel) Temp.Diff. (sTd)
28 Deg. / 214 Ft. Above Sea Level
41 Deg. F
70 Deg. F
29 Deg. F
40 Deg. F
91 Deg. F
76 Deg. F
113
50%
51
75 Deg. F
62.3 Deg. F @ 64 Gr/Lb
17 Deg. F M
16 Deg. F
20 Deg. F
* HEATING SUMMARY * MF96S
------------------------------------ ---------------------------------------
SUBTOTAL
.DAT * COOLING SUMMARY *
19188.06 :STRUCTURE SENSIBLE
:MECH.VENT- 0 Cfm
:SENS. + MECH.VENT
:TEMP.SWING @ 3 DEG.
: OCCUPANT/APPLIANCE
959.40 :DUCT GAIN
20147.46 :TOTAL SENSIBLE
:TOTAL LATENT
DUCT LOSS
TOTAL LOSS/BTUH
:SENSIBLE + LATENT
20% OVERSIZE FACTOR 4029.49 :20% SENS.OVRSZE FTR:
ACTUAL + 20% OVERSIZE: 24176.95 :SENS. + 20% OVERSIZE:
* EQUIPMENT SELECTION *
EQT MANUF GOODMAN
HTG INP/BTUH STRIP
SENSIBLE BTUH 16800
TONAGE 1.9 (S)EER 10
NOTES:
CU MOD # CK24-1
HTG OUTP/BTUH STRIP
LATENT BTUH 6200
CLG CFM 800
AHU MOD # A24-05
AFUE/HSPF 1 TYPE A/C
TTL CLG BTUH 23000
HTG CFM 800
6513.79
0.00
6513.79
1. 00
2400.00
891. 38
9805.17
2476.77
12281.94
1961. 03
11766.20
,
GLASS
* LOA D
C A L C U L A T ION *
S All Shaded
Type Shdg Sc OvHg Botm Hgt
S.C. R.S. 1 2 6 5
Area Loss/Btuh
20.00 924.00
Gain/Btuh
420.00
S All Shaded
-------------------------------------------------------------------------------
S.C. R.S. 1
2
6
5
20.00
924.00
420.00
N No Shd Fctr
-------------------------------------------------------------------------------
S.C. R.S. 1
2
6
n/a
20.00
924.00
420.00
N No Shd Fctr
-------------------------------------------------------------------------------
S.C. R.S. 1
3
8
n/a
42.00
1940.40
882.00
Infiltration Winter Htm ( 32.12 )
Infiltration: Summer Htm ( 8.03 )
-------------------------------------------------------------.------------------
x
x
102.00
102.00
3276.24
819.06
R-Value Area Loss/Btuh Gain/Btuh
W ALL S---------------________________________________________________________
Wood Stud - Adj. 11 320.00 1152.00 416.00
Wood Stud - Adj. 11 320.00 1152.00 416.00
N/W C.B. - Int Insul - Ext. 4.2 192.00 1113.60 441.60
N/W C.B. - Int Insul - Ext. 4.2 192.00 1113.60 441.60
SUBTOTALS: 1024.00 4531.20 1715.20
D 0 0 R S---------------______________________________________._________________
Solid Core/Wood - Ext. 0 21.00 598.50 228.90
Infiltration :Winter Htm( 32.12 ) x 21.00 674.52
Infiltration :Summer Htm( 8.03 ) x 21.00 168.63
SUBTOTALS: 21.00 1273.02 397.53
C ElL I N G S-------------___________________________________________________
Under Attic 30 960.00 1248.00 1440.00
F L 0 0 R S-------------_______________________________________________________
Slab on Grade 0 128.00 Lin.Ft. 4147.20 000.00
-------------------------------------------------------------------------------
* TOTAL STRUCTURE SENSIBLE *
-------------------------------------------------------------------------------
19188.06
6513.79