HomeMy WebLinkAbout98-7622
BUILDING PERMIT 7622 13
Permit
Permit
Signatur
Company
Address ~
Telephone# ~5~1.. SIV~
~~
BUILDING
CITY OF ZEPHYRHILLS
(813) 788-6611
/7J~1
MECHANICAL
7J~/J
ELECTRICAL
...
)j~t1
PLUMBING
~opertyOwne, ~sfP/~"d
Job Address: ...g ..-...A
Parcel 1.0. # 12 - d- & .J/-O~ .. CJ n LJ 0 CJ.~ 030 0
Zoning: Ener2e: dadoaas:~O . '...3
DescriDtion of WOrk~LA.-.) ~ -1JL \;t:l .. J J. A... 1t~
-5.??~?-;;L9-7?' r~ ~ ;2.'36) nnr
NO OCCUPANCY BEFORE CoO,
FINAL
Complete Plans, Specifications and Fee Must Accompany Application. CoO,
All work shall be performed in accordance with City Codes and Ordinances.
Valuation or U
Contract Price T :2....J <........;J..... O. c.rv
Date ...2 -;;lb ~ 9 y
Sewer Conn
Water Conn:
/ J.7j';tJl;J
J...5'7.OV
la&-OV
Water Meter:
T.I.F.'s:
City License Registration # I 7..S
State Certified License#
11n#~~;~ ~j. JJ1~I~_ 97
(~Jhr~ /{J,
PL MBING
SLB <{h'''~i g,'((
Tub Set b-J.fJ-,flfrCt ~I
Water~
Sewer II' 7~
Final
BUILDING
Ftr. '-/hlqi [6 E.
Pre SLB 4/'J'-I1 q ~ ~:U-
Lintel
ELECTRICAL
Tp. Servo
Rough In b-/~- (jJ3A)1
Meter Can
/ - /~ ' Cj) ~ 13, t.. '-
FRM. t::J Const. Pole
Insul. CL Pool
WL 6-12-9~ IU~ Pre-Meter 1~29./r8 ~
_/1 I Final
Driveway ~ll/ii B/t\ I;o-kr g.~ '-l!:/t g
~S;J519~6ILL ,1~ ;:/
~LK~
~ECH~NICAL /
Breakers
Ducts Insl. ,j,-le-qaJfLy
Compressor
Final
REINSPECTION FEES: When extra inspection trips are necessary due to anyone of the following reasons, a
charge of Fifteen and 00/100 Dollars ($4-6-:eE)) shall be made for each trip for each trade:
~--;tl7J
a.
b.
C.
d.
e.
f.
g.
Wrong Address
Condemned work resulting from faulty construction.
Repairs or corrections not made when inspection called,
Work not ready for inspection when called.
Permit not posted on job site.
Plans not at job site.
Work not accessible.
)/ ~~/~d6'-Yr
~~ jJ - if&u.Hl -IO/z "/<: Ji'
rJ 'th/'1~
The payment of inspection fees shall be made before any further permits will be issued to the person owning
same.
:..,
T.l. HtWOK & A33oeiaW. 9He.
CtWuffhtg eMgiMwt6
June II, 1998
To whom it may concern:
RE: Habitat for Humanities
House # 6 Lincoln Heights
Zephyrhills, FL
To offset a pre-engineered truss delivery problem from the factory, I specified the conventional
framing members consisting of rafters, collar ties, ceiling joist and other necessary structural
members for the roof and ceiling to minimize construction delays.
This design meets or exceeds requirements of the Standard Building Codes.
If anyone needs information or clarification concerning this, please call.
Sincerely,
~.........
P.D.Bu." 1728, Vade City, f.c 33526 (352) 521-5848
_TUN- 12-"3'::'
FPI
13:55
T _ L _
H A t"~ '::; 0 t"~
A:::: :::;:; '=1 1=: _
I t.~ C
P.C12
rT..c. H~(U( & A330.cUde3, 9KC.
C1m6uWug eKg~
June 11. 1998
To whom it may concern:
RE: Habitat for HllInanitics
House #- 6
39511 Lincoln A v~nue
Zephyrhills, FL 33540
To offsl:t a pre-engineered truss delivery problem from th~ factory, I specified the conventional
f)'aming membors consisting ofrafrcrs, co 11m ties, ceilingjoist and other necessary structural
members for the roof and ceiling to minimize construction delavs.
~ .
This design mc~ts or exceeds requirements of the Standard Bllilding Codes.
[f anyone needs informatlon 01' c1mificmion concerning this, please call.
Sincerely,
~'I!
-' "b' 'I
- -- . -"O~
Tham; j~.'f.t~1l1son, PE
'-
P.O. 'Bax 1728. Vcule Cilg. F.c 33526 (352) 521-5848 J
HABITAT FOR HUMANITY
39511 LINCOLN AVE.
SQ. FEET PRICE
MAIN OR LIVING AREA 1,063 $ 40.00
OTHER AREA UNDER ROOF $ 15.00
OTHER - $ 0.85
VAlUATION $ 42,520,00
FEE SHEET
ADDRESS $ -
DRIVEWAY $ -
BUILDING: WAIVED
ELECTRICAl: WAIVED
PlUMBING: WAIVED
MECHANICAl: WAIVED
RADON: $ 10.63
CREDIT:
TOTAL $ 10.63
SEWER: $ 1,278.00
WATER: $ 350,00
TOTAL: $ 1,628.00
~
3/4" WATER METERI $
180,00 I
TI F'S: WAIVED
99% WAIVED
1% WAIVED
TOTAL: $ 1,818.63
: ;;
:.:': Jr. :) I (";~ F- ~<-~ I~r-' r i_ i,_.'~1 ; in! ill. ,i: ::.; ,
')c-j."
tl:.:a:v' F'i I)
APPLIcAnOIC PCiR PmUfJ'T
CIn OF ZEl"IIYJUIJ:LL
RIJUDllIC DEI'AKDIEltCT
_, __~o --1 y
....)
OW~EA . ~.
~:r~~4:)~hr#T~~ /L///-/i//~Y fUoME 3501-,)67 / y'~y
..ko_,~~---.L7JL''''d.d~/4-r;T' .r.l.. 3~ s-~ b
J.L2LL_...k~ /:4/ /()
3t.
0WIfER '5 ADDRRSS
~J08 ADDIlRSS___ ___~ _
Ul'.("-'L DRSClUPTIOIII~ 1.Dl'(S) ,
_.___~OBDIVI.SIOac
o.;;..?D
PARCF.I. 1. IL . / ~ -...l b - -2. I. - Q.d.flP -:.(2 t;!!/2..t!!P - 0 -' ~ 0
WORK PROPOSED: 0ev COO8tructiOll _pJdit,j,.,,. -.....Alterat.ion ~Repair _lDstall
-.fiign
--""ve
---'>atollsh
PROrmilU) Wl,SL....Dinale r_ily
., --.Jj/F
_' of Units
-Jl1 B
_('~tc1al
_Indust:.
_svt.. Poul
Otht"r
_ _JlesUtttant: II lIf'..a.l t.h Depar~t: Approva1
BUILDIHG SIZE: ._ ..~_---^--,
I't? h3 ~u.are. Feet,
/
Height
. RBSIDENTlAL; A'fT^aI (2) PIDI' PLAlIS &: (2) SEIS OF BD1lJ)I>>C PLANS &: (1) SET ItIIERCY FORMS x U
cottHERC'IAL: A'nAaI (3) SB'I'S OF BUTLDDG PI.MS &: (1) SET ERERCY fORKS.**
~. 4COP'f' OF WRTRACT REQUDED.
PEJMlTS RblUF-C;TED
--lJUTLDno
$
3,2' cO
J CJc.c; , ------
/
VAluation of ToU~ Con.~r::nlrt:ion
P.T .ECl'RlCAL
.NIP Service
/ .Florida Power Corp.
__W.R..E.C.
_..~CAL
s
Va1uatioo. of Kccb.anica1 lnsta1.1.atioo.
_ltl..llf{9TIlC
_CAS
,HOUYl.Nc;
SPECIALTY
. TYPE OF COi'{;;nmcnOll: ----.Jloclt. ~ _St.eel
Other
PDlsmm FLOOR RUNATIOIIS: 0
FT.
IS I'HO.JECT IJ( FLOOD ZOME ARY.A 1
YES NO
--..,
\.
*......*.*******.........**********....*..
CW'J1L\L"tOR SEf;J'J..W{
/lJIWlQ! ~ WltPANY~~ ~ ~(/O?////) /
State Ceet. or Regist _ t~<:!:;;; - -;-/"") 3G 5:1..1-
Sjgnat~'tt<;; ~ . __ City LicE'nse Registration t /93 - C(5 c 0 .J~ $I fJ
*....~...*.~***...****.t..*..........tt
~1.P.cTR"(CIAIf
Sivnarure l~~
aJlfpAXY Mkl1.!~___ Clee-.>f/"'l C /
/) lil /J 5t:aU Gen.. or Kegist:.' el...t::o{X 'ftl'7 V
r. {/"'-z./' ~_ City License Registration f qj
...........................~~........ ,I
{mPAJiY '/l.l/. _Jfll1..t.5 [!C--vlt ~'v,1..
State CA!r1:. or Ilkgtst./ ,_ _ /f/- <2ak (; '-16 '7 __on /'
..-___..____ City Lic~e RCAlstra'tioo , / t.. (,
***......*****........******.**........**
WVAft___. ;;1';1# Z ~~. ~ _-_____ /
SLate Cer.... ur Regist. t. . if. i)h;l d
City License Registratinn t /~/
........*.*........**...........*.**. '
t.r.IJU:;B.
CO!(PANY
SUte (;fort. or Regist_ ,
City Lh:e.aae Registrat.ion . __
.....***......*..*........................
:; i gUllture
APPLlCAnOR A'PPROVED BY ____.
PElUur OFFICER.
I'j j,'TPAI. F'F'PNITTING
PASCO cnUNTY, FLORtOA
DATF: 10/30/98 TIME: 13156
P,'ICE t 1 OF .,
rssur CWFICF: D
RECEIPT HUMBRI 00382617
nrrrCF: DADE CITY
CONTPACTCIP :It:
NAME: BOB LARKIN CONST,
ADDR: :39~i 11 I. n-!CnLN All
CIST ~ CTTY OF ~~:/IIJ:LL <3
,. fll~~ :
rHFT~I< =II 7 j 6~)
AceNT
j j I.~
TClTAL ANOUNT:
COMPNY AccnUNT CENTER
aq50 - 363000 - ?
H,81
AMnUNT DESCRIPTION/PERMT DATA DRICR
8.81 **..** SOLID WASTE FEF 60
PfTfI\lFD RY ~cf:~~____i1~~_~_
PASCO COUNTY, FLORIDA
Date Permitted
7- hJd fJJ
3/~ & jqg
, I
Permit No.
606 "-fH<K I ^J Cen.sftt-u c {-/c9n
County Parcel No. 'd - d.&, - ~ I - 0;). DO - mODO - 031fJ 0
3q5 i I '--{NeoLA! /tile,
Kes/4 eiJ,t{ I -
Builder Name/Owner Name
Location
____ Subd.
Ih(j]itO 11 I J J/-
TRANSPORTATION IMPACT FEE CALC
Hf4t5 I T flI rat-
D
Classification/Type of Use
Rate $
Sq. Ft./Unit
Prepared By
Impact Fee Amount $
The above impact fee has been established pursuant to the Pasc County Transportation Impact Ordinance as adopted
by the Board of County Commissioners. This amount is payable PRIOR to the issuance of a Certificate of Occupancy
or authority to utilize the permitted structure.
RESOURCE RECOVERY ASSESSMENT
EXEMPT D
RESIDENTIAL
NONRESIDENTIAL
No. Units
Gross Sq. Ft. (GSF)
Rate/ERU - 52.00/Year
or $0.142/Day
ERU Assign No.
Assessment - (No. Units) x ($0.142)
x (No. Days)
Assessment -
(GSF) x (ERU) x (0.142) x (No. Days)
100
TOTAL FEE $
TOTAL FEE $
The above assessment has been established pursuant to the Pasco County Ordinance No. 89-07 and Resolution No. 89-197,
as commended.
THE ASSESSMENT WILL BE CALCULATED AT THE TIME OF ISSUANCE OF THE CERTIFICATE OF
OCCUPANCY.
NO CERTIFICATE OF OCCUPANCY OR FINAL POWER RELEASE WILL BE ISSUED UNTIL THE AMOUNTS LISTED
HA VE BEEN PAID AND RECEIPTED FOR BY A CENTRAL PERMITTING OFFICE OF PASCO COUNTY.
Acknowiedgement below does not imply acceptance of concurrence, but simply receipt of a copy of this form, placing
the building permit owner on notice of this assessment and the conditions of payment for same.
Date
Received By
---------------------------------------------------------------------------------------------------------------------------------------------------
OFFICE USE ONLY
TRANSPORTATION REC. NO.
RESOURCE RECOVERY REC. NO. .~ Y ~. ? J 7
DATE BY
DATE /tJ - 30 . 9'~ By....
White
Applicant
Canary
Trans/Finance
Canary
RR/Finance
Pink
Office
Green
Bldg/lnsp
feecal:ce
PC93113094/
Department of Community Affairs
FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION
Residential Component Prescriptive Method A
Habitat for Humaniti BUILDER: Habitat for Humanities
Lot 36. Lincoln Avenu PERMITTING CLIMATE
Zephyrhills, FL 3354 OFFICE: Zephyrhills ZONE: 41XI 51_1 61_1
OWNER: -d'7..s,..... / I ~ PERMIT NO. /"J../l~ JURISDICTION NO. 611600
CK
1. New construction or addition
2. Single family detached or Multifamily attached
3. If Multifamily-No. of units
4. If Multifamily, is this a worst case (yes/no)
5. Conditioned floor area (sq.ft.)
6. Predominant eave overhang (ft.)
7. Porch overhang length (ft.)
8. Glass area and type:
a. Clear Glass
b. Tint, film or solar screen
9. Floor type and insulation:
a. Slab on grade (R-value, perimeter)
10.Net Wall type area and insulation:
a. Exterior: 2. Wood frame (Insulation R-value) 10a-2 R=14.30, 828.70sqft
11.Ceiling type area and insulation:
a. Under attic (Insulation R-value)
12.Air distribution systems
a. Ducts (Insulation + Location)
14.Heating System:
~
FORM 600A-93
PROJECT NAME:
AND ADDRESS:
15.Hot water system:
16.Hot Water Credits: (HR-Heat Recovery,
DHP-Dedicated Heat Pump)
17.Infiltration practice: 1, 2 or 3
18.HVAC Credits (CF-Ceiling Fan, CV-Cross vent,
HF-Whole house fan, RB-Attic radiant
barrier, MZ-Multizone)
19.EPI (must not exceed 100 points)
a. Total As Built points
b. Total Base points
I Hereby certify that the plans and
specifications covered by this calcu-
lation are in compliance with the
Florida Energy Code.
PREPARED BY:
DATE:
I hereby certify that this building is
in compliance with the Florida Energy
Code.
OWNER/AGENT:
DATE:
SN: 1234
CENTRAL
New Construction
Single-Family
o
1.
2.
3.
4.
5.964.00
6. 2.00
7. 6.00
Single Pane
8a.136.2sqft
8b. 0 . Osqft
Double Pane
O.OOsqft
O.OOsqft
9a.R= 0.00 , 129.30 ft
11a.R=33.30 , 964.00sqft
12a. R= 6.00, uncond
14. Type: Strip Heat
COP: 1.00
Type: Electric
EF: 0.95
15.
16.
17.
18.
2
19.
19a.
19b.
98.68
23005.95
23314.81
Review of the plans and specifications
covered by this calculation indicates
compliance with the Florida Energy
Code. Before construction is completed
this building will be inspected for
compliance in accordance with Section
553.908 F.S.
COMPONENTS
** INFILTRATION REDUCTION PRACTICE COMPLIANCE CHECKLIST **
REQUIREMENTS FOR EACH PRACTICE
===============================================================================
SECTION
CHECK
================================================================================
PRACTICE #1
606.1
COMPLY WITH ALL INFILTRATION PRESCRIPTIVES.
--------------------------------------------------------------.-----------------
Windows
606.1
Maximum of 0.34 CFM per linear foot of operable sash
crack (includes sliding glass doors) .
Exterior &
Adjacent Doors
--------------------------------------------------------------.-----------------
606.1
Maximum of 0.5 CFM per sq. ft. of door area: solid
core, wood panel, insulated or glass doors only.
Exterior Joints
& Cracks
-------------------------------------------------------------------------------
To be caulked, gasketed, weather-stripped or other-
wise sealed.
606.1
PRACTICE #2
-------------------------------------------------------------------------------
COMPLY WITH PRACTICE #1 AND THE FOLLOWING:
606.1
-------------------------------------------------------------------------------
Exterior Walls
& Floors
606.1
Top plate penetrations sealed. Infiltration barrier
installed. Sole plate/floor joint caulked or sealed.
Exterior Walls
& Ceilings
-------------------------------------------------------------------------------
606.1
Penetrations, joints and cracks on interior surface
caulked, sealed or gasketed.
DuctWork
-------------------------------------------------------------------------------
Ductwork in unconditioned space must be sealed.
606.1
Fireplaces
-------------------------------------------------------------------------------
Equipped with outside combustion air, doors and flue
dampers.
606.1
Exhaust Fans
-------------------------------------------------------------------------------
Equipped with dampers. Combustion devices see
606.l.A.2.
606.1'
Combustion
Appliances
-------------------------------------------------------------------------------
606.1
Be in unconditioned space (except direct vent), draw
air from unconditioned space, exhaust to outside.
Cooking appliances shall be dampered and use
intermittent ignition.
-------------------------------------------------------------------------------
Water Heaters
** OTHER PRESCRIPTIVE MEASURES (must be met or exceeded by all residences.) **
-------------------------------------------------------------------------------
612.1
Comply with efficiency requirements in Table 6-12.
Switch or clearly marked circuit breaker (electric)
or cutoff (gas) must be provided. External or built-
in heat trap required.
--------------------------------------------
Swimming Pools
& Spas
612.1
-----------------------------------
Spas and heated pools must have covers (except solar
heated). Non-commercial pools must have a pump timer.
Gas spa & pool heaters must have a minimum thermal
efficiency of 78 percent.
Shower Heads
----------------------------------------
---------------------------------------
612.1
Water flow must be restricted to no more than 3 gal-
lons per minute at 80 PSIG.
-----------------------------------------------
HVAC Duct
Construction
Insulation &
Installation
HVAC Controls
610.1
--------------------------------
All ducts, fittings, mechanical equipment and plenum
chambers shall be mechanically attached, sealed, ins-
ulated and installed in accordance with the criteria
of Section 610.1.ABC.2 & 610.1.ABC.3. Duct in attics
must be insulated to a minimum of R-6. Air handlers
shall not be installed in attics unless in mechanical
closet.
607.1
-----------------------------------------------------------
Separate readily accessible manual or automatic
Insulation
604.1
602.1
-------------------------------------------------------------~------------------
thermostat for each system.
Ceilings minimum R-19. Common Walls - Frame R-11 or
CBS R-3 both sides. Common ceiling & floors R-11.
--------------------------------------------------------------------------------
*************************************************************~.*****************
SUMMER CALCULATIONS
*************************************************************~.*****************
=== BASE ===
=== AS-BUILT ===,
g~~~~--~~~~-~-~~~~-:- POINTS I
TYPE
==============================================================:=================
SC ORIEN AREA x SPM x SOF = POINTS
-------------------------------------------------------------------------------
E 66.40 82.2 5458.1 SGL CLR E 33.2 109.2 .52 1885.2
SGL CLR E 33.2 109.2 .80 2903.0
S 26.70 82.2 2194.7 SGL CLR S 16.6 100.2 .80 1336.2
SGL CLR S 10.1 100.2 .73 734.3
W 43.10 82.2 3542.8 SGL CLR W 16.6 109.2 .80 1456.2
SGL CLR W 20.2 109.2 .68 1508.0
SGL CLR W 6.3 109.2 .68 470.3
.15 x CONDo FLOOR / TOTAL GLASS = ADJ. x GLASS
AREA AREA FACTOR POINTS
-------------------------------------------------------------------------------
ADJ GLASS
POINTS
GLASS
POINTS
.15
11,195.64
-------------------------------------------------------------------------------
10,293.27
964.00
136.20
1.062
11,886.12 I
-------------------------------------------------------------------------------
-------------------------------------------------------------------------------
NON GLASS------------ I
AREA x BSPM = POINTS TYPE
R-VALUE
AREA x SPM = POINTS
WALLS----------------
Ext 828.7 1.0 828.7
Ext Wood Frame
-------------------------------------------------------------------------------
DOORS----------------
Ext 37.0 4.8 177.6
Ext Insulated
Ext Insulated
CEILINGS-------------
UA 964.0 .6 578.4
Under Attic
FLOORS---------------
Slb 129.3 -31.8 -4111.7
Slab-an-Grade
INFILTRATION---------
964.0 10.9 10507.6
Practice #2
==============================================================:=================
TOTAL SUMMER POINTS I
19,866.68
14.3 828.7 1. 55 1283.1
21. 6 4.80 103.7
15.4 4.80 73.9
33.3 964.0 .52 498.9
.0 129.3 -31.90 -4124.7
964.0 10.90 10507.6
TOTAL x
SUM PTS
COOLING I TOTAL
POINTS COMPON
==============================================================:=================
18,635.77
x CAP x DUCT x SYSTEM x CREDIT = COOLING
RATIO MULT MULT MULT POINTS
SYSTEM
MULT
19,866.68
7,350.67 I 18,635.77 1.00 1.070
------------------------------------------------------.-----------------
6,471.84
.37
.325
1.000
================================================================================
*******************************************************************************
WINTER CALCULATIONS
*******************************************************************************
=== BASE ===
=== AS-BUILT ===
===============================================================================
~~~~~--~~~~-~-~~~~-:- POINTS I
TYPE
SC ORIEN AREA x WPM x WOF = POINTS
-------------------------------------------------------------------------------
E 66.40 -3.4 -225.8 SGL CLR E 33.2 -2.2 -2.03 148.3
SGL CLR E 33.2 -2.2 -.08 6.2
S 26.70 -3.4 -90.8 SGL CLR S 16.6 -10.9 .86 -155.6
SGL CLR S 10.1 -10.9 .77 -85.0
W 43.10 -3.4 -146.5 SGL CLR W 16.6 -2.2 -.07 2.6
SGL CLR W 20.2 -2.2 -.76 33.7
SGL CLR W 6.3 -2.2 -.76 10.5
-------------------------------------------------------------------------------
.15 x CONDo FLOOR / TOTAL GLASS = ADJ. x GLASS
AREA AREA FACTOR POINTS
ADJ GLASS
POINTS
GLASS
POINTS
-------------------------------------------------------------------------------
.15
964.00
136.20
1.062
-463.08
-491.64 I
-39.37
===============================================================================
NON GL~~~~--~--~~~~-: POINTS I TYPE
R-VALUE
AREA x WPM = POINTS
-------------------------------------------------------------------------------
WALLS----------------
Ext 828.7 1.1 911.6 Ext Wood Frame 14.3 828.7 1. 65 1366.0
DOORS----------------
Ext 37.0 5.1 188.7 Ext Insulated 21. 6 5.10 110.2
Ext Insulated 15.4 5.10 78.5
CEILINGS-------------
UA 964.0 .6 578.4 Under Attic 33.3 964.0 .52 498.9
FLOORS---------------
Slb 129.3 -1. 9 -245.7 Slab-an-Grade .0 129.3 2.50 323.3
INFILTRATION---------
964.0 4.1 3952.4 Practice #2 964.0 4.10 3952.4
================================================================================
TOTAL WINTER POINTS I
4,893.76
6,289.82
================================================================================
TOTAL x
WIN PTS
SYSTEM
MULT
HEATING I TOTAL
POINTS COMPON
x CAP x DUCT x SYSTEM x CREDIT = HEATING
RATIO MULT MULT MULT POINTS
---------------------------------------------------------------------
4,893.76 1.10
5,383.14 I 6,289.82 1.00 1.070
1.000
1.000
6,730.11
================================================================================
*******************************************************************************
WATER HEATING
*******************************************************************************
=== BASE ===
=== AS-BUILT ===
===============================================================================
NUM OF
BEDRMS
x
MULT
TOTAL
TANK VOLUME
EF
TANK
RATIO
x MULT x CREDIT
MULT
= TOTAL
-------------------------------------------------------------------------------
3
3527.0
10,581. 00
50
.95
1.000
3268.0
1. 00
9,804.00
-------------------------------------------------------------------------------
-------------------------------------------------------------------------------
*******************************************************************************
SUMMARY
*******************************************************************************
=== BASE ===
=== AS-BUILT ===
COOLING
POINTS +
===============================================================================
HEATING
POINTS
HOT WATER
+ POINTS
TOTAL
POINTS
COOLING
POINTS
+
HEATING
POINTS
HOT WATER
+ POINTS
TOTAL
POINTS
-------------------------------------------------------------------------------
7350.7
5383.1
10581.0
23,314.81
6471.8
6730.1
9804.0
23,005.95
===============================================================================
*****************
* EPI =
98.68
*
*****************
ENERGY GUIDE
For detailed information
of the EPI rating number
or for any ITEM listed,
ask your Builder for
DCA Form 600A-93
or Form 600B-93
EPI= 98.7
o 10 20 30 40 50 60 70 80 90 100
I---------------------------------------x-I
The maximum allowable EPI is 100. The lower the EPI the more efficient the home
RESIDENTIAL ENERGY PERFORMANCE RATING SHEET
ITEM
HOME VALUE
Low Efficiency
High Efficiency
WINDOWS.................... .Single Clear
SINGL CLR DBL TINT
Ix--------------------I
INSULATION. . . . . . . . . . . . . . . . . .
Ceiling
R-Value......... 33.3
R-10 R-30
I--------------------xl
R-O R-7
I--------------------xl
R-O R-19
Ix--------------------I
Wall
R-Value......... 14.3
Floor
R-Value......... 0.0
AIR CONDITIONER. . . . . . . . . . . . .
SEER/EER. . . . . . . . . . . . . . . . .. 0.0
10.0 SEER 17.0
1---------------------1
9.7 EER 16.0
HEATING SYSTEM. . . . . . . . . . . . . .
Electric COP/HSPF........ 1.0
2.50 COP 4.19
Ix--------------------I
0.78 AFUE 0.90
1---------------------1
Gas AFUE............ 0.00
WATER HEATER. . . . . . . . . . . . . . . .
Electric EF.............. 0.95
0.88 0.96
I-----------------x---I
0.54 0.90
1---------------------1
0.40 0.80
1---------------------1
Gas EF. . . . . . . . . . . . .. 0.00
Solar EF. . . . . . . . . . . . . .
OTHER FEATURES.... . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . .
I certify that these energy saving features required for the Florida
Energy Code have been installed in this house.
Builder
Signature:
Date:
Address:
City/Zip
Florida Energy Code for Building Construction - 1993
Florida Department of Community Affairs
FL-EPL CARD93