HomeMy WebLinkAbout99-8824
,~),~
BUILDING
BUILDING PE,RMIT, 8824
CITY OF ZEPHYRHILLS Permit
(813)788-6611 Date l./Ib /91
'Is. 11. L./ 1. fE. J~' ~
ELECTRICAL PLUMBING MECHANICAL Sewer Conn
Property Owner: S:~I'~ (..' ILl o..nJ
Job Address: 5c.t Jo -g~ Sf"
ParceII.D.# il-)b-ll- OO/O-IJDOO-O-JIO
.,C
Zoning: Energy Code: Radon Gas: 2. -
Descriotion of Work N (! t...) be.J r (.) f'....., bG\. +( 1'0 (I ...... / I Co. u..." ol r i rOO rt I
f
Water Conn:
Water Meter:
T.I.F.'s:
;- A~' L.vo.-y
NO OCCUPANCY BEFORE C.O.
FINAL
C.O.
9./e:1 1-
DATE
Complete Plans, Specifications and Fee Must Accompany Application.
All work shall be performed in accordance with City Codes and Ordinances.
DATE
City License Registration #
State Certified License#
'2237
Inspector
Valuation or --1:j/' , L1 00 ~
Contract Price f'"
Signatur
Company
Address
Telephone#
8/3- ;2.~g- 66~/
K(.?AA -I- /tIc
MECHANICAL ;)l f 2
P~{ J. .s i erl'Q
~<, >>..
BUILDING
Bc...rCD f(ec.
:>231
ELECTRICAL
Ftr. g.~ 19" qq jB I '--L Tp. Serv.
Pre SLB Rough In Cf'/Z-]X( ~
Lintel Meter Can
~n~~': ct'l~ ~'7~ ~; ~ II ~:~,.t. Pole
WL _ _ _ (I Pre-Meter
Final
SLB 8'- 3o-qct Rl-;~_
Tub Set 9" "[-99 01 L
Water
Sewer
Final
Breakers
Ducts Insl. 9~2-'Tti~
Compressor
Final
Driveway
f~ ~~ ~U -'I It €. \.,.L
~~<t..I~Cfcr~
- - REINS~CTION FEES: When extra inspection trips are necessary due to anyone of the following reasons. a
charge of Fifteen and 00/1 00 Dollars ($ 25.001 shall be made for each trip for each trade:
a. Wrong Address
b. Condemned work resulting from faulty construction.
c. Repairs or corrections not made when inspection called.
d. Work not ready for inspection when called.
e. Permit not posted on job site.
f. Plans not at job site.
g. Work not accessible.
The payment of inspection fees shall be made before any further permits will be issued to the person owning
same.
-....
FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION
FORM 600C-97 Residential Limited Applications Prescriptive Method C CENTRAL 4 5 6
Small Additions, Renovations & Building Systems Department of Community Affairs
Compliance with Method C of Chapter 6 of the Florida Energy Efficiency Code may be demonstrated by the use of Form 6OOC-97 for additions of 600 square feet or less, site- installed components
of manufactured homes, and renovati ns to si gle and multifamily residences. Altemative methods are provided for additions by use of Form 6ooB-97 or 600A-97.
OWNER:
BUILDER:
PERMITTING CLIMATE FVl D
OFFICE: ZONE: 4 ~ 5 6 D
PERMITNO.~ JURISDICTION NO.: ~
PROJECT NAME:
AND ADDRESS:
SMALL ADDITIONS TO EXISTING RESIDENCES (600 Square feet or less of conditioned area). Prescriptive requirements in Tables 6C-1. 6C-2 and 6C-3 apply only to the
components of the addition. not to the existing building. Space heating, cooling, and water heating equipment efficiency levels must be met only when equipment is installed
specifically to serve the addition or is being installed in conjunction with the addition construction. Components separating unconditioned spaces from conditioned spaces must
meet the prescribed minimum insulation levels. RENOVATIONS (Residential buildings undergoing renovations costing more than 30% of the assessed value of the building).
Prescriptive requirements in Tables 6C-1 and 6C-2 apply only to the components and equipment being renovated or replaced. MANUFACTURED HOMES AND BUILDINGS. Only site.
installed components and features are covered by this form. BUILDING SYSTEMS Comply when complete new system is installed. Please Print CK
1. Renovation, Addition, New System or Manufactured Home
2. Single family detached or Multifamily attached
3. If Multifamily-No. of units covered by this submission
4. Conditioned floor area (sq. ft.)
5. Predominant eave overhang (ft.)
6. Glass area and type:
a. Clear glass
b. Tint, film or solar screen
7. Percentage of glass to floor area
8. Floor type and insulation:
a. Slab-on-grade (R-value)
b. Wood, raised (R-value)
c. Wood, common (R-value)
d. Concrete, raised (R-value)
e. Concrete, common (R-value)
9. Wall type and insulation:
a. Exterior:
1. Masonry (Insulation R-value)
2. Wood frame (Insulation R-value)
b. Adjacent:
1. Masonry (Insulation R-value)
2. Wood frame (Insulation R-value)
c. Marriage Walls of Multiple Units* (Yes/No)
10. Ceiling type and insulation:
a. Under attic (Insulation R-value)
b. Single assembly (Insulation R-value)
11. Cooling system*
(Types: central, room unit, package terminal AC., gas, existing, none)
12. Heating system*: (Types: heat pump, elec. strip, natural gas, L.P. gas,
gas h.p., room or PTAC, existing, none)
13. Air Distribution System*:
a. Backflow damper or single package systems* (Yes/No)
b. Ducts on marriage walls adequately sealed* (Yes/No)
14. Hot water system:
(Types: elec., natural gas, other, existing, none)
* Pertains to manufactured homes with site installed components.
1 hereby certify th.at t lans and SpeC!!'fi ati~ered by the calculation are in
compliance witli tt] I a Energy de. .--' ~ A
PREPARED BY: -. t~ . 1 .----./"" DATE: 7 7'7
I hereby certify that this building is in compliance with the Florida Energy Code.
OWNER AGENT: DATE:
1. fJ-OD/-rf '0 /--...J
2. sir
3.
4. 3G,O
5. I ~/(
Single Pane Double Pane
6a. '--It? sq. ft. sq. ft.
6b. sq. ft. sq. ft.
7. /~ 0/0
8a. R= ~ s-'I /in. ft.
V"
8b. R= sq. ft.
8c. R= sq. ft.
8d. R= sq. ft.
8e. R= sq. ft.
9a-1 R= S- 3~tf sq. ft.
9a-2 R= sq. ft.
9b-1 R= ,J -2--20
sq. ft.
9b-2 R= sq. ft.
9c
10a. R= 30 .3ra 0 sq. ft.
10b. R= sq. ft.
( \
11. Type: ~~( f:.11I'Jd
SEERlEER: I ()
12. Type: f/.e n7 PI.A H1f
HSPF/COP/AFUE: 7. "2-
13a.
13b. '"----
14. Type: e.l-ec
EF: -~~
Review of plans and specifications covered by this calculation indicates compliance
With the Flonda Energy Code. Before construction is completed, this building will be
inspected for compliance in acs:ordance . Section 553.908. F.S.
BUILDING OFFI L: ./.. /L
DATE:
-.-
Revised 1998
Climate Zones 4 5 6
TABLE 6C-1 : PRESCRIPTIVE REQUIREMENTS FOR SMALL ADDmONS (600 Sq. FL and Less), RENOVATIONS TO EXISTING BUILDINGS AND SITE.INSTALLED COMPONENTS OF MANUFACTURED HOMES.
MINIMUM INSULATION MINIMUM INSTALLED
COMPONENT INSULATION INSTALLED EQUIPMENT EFFICIENCY EFFICIENCY
Concrete Block R-5 v-~ Central AlC - Spl~ SEER = 10.0 SEER = /().o
(/) Frame, 2' x 4' R-ll ---, (!)
:z: -Single Pkg. SEER 9.7 SEER
..J Frame, 2' x 6' R-19 - ::; = = -
..J 0
<( Common, Frame R-ll ~ 0 Room unit or PT AC EER = 8.5' EER =
~ K--z;. () -
Common, Masonry R-3
Under Attic R-30 (.I ~~- Electric Resistance ANY
(/) Single Assembly; Enclosed (!) Heat pump - Split HSPF = 6.8 HSPF = 7.1.--
(!) - :z:
Z Frame R-19 ~ - Single Pkg. HSPF = 6.6 HSPF = -
:J Metal Pans R-13 - -
W Room unit or PTHP COP 2.7' HSPFI -
W Single Assembly; Open R-l0 I = = -
() W
Common, Frame R-ll -' ~ COP
a.. Gas, natural or propane AFUE = .78 AFUE =
(/) Slab-on-grade No Minimum ?' en -
a: Raised Wood R-ll Fuel Oil AFUE = .78 AFUE = ~.
0 -
0 Raised Concrete R-5 ,8'g
..J Common, Frame R-ll a: Electric Resistance EF .88 EF
LL I-W = =
I- In unconditioned space R-6 O!;;( Gas; Natural or L.P. EF = .54 EF =
() I3: -
=> In conditioned space No minimum Fuel Oil EF = .54 EF =
0
. See Table 6.3, 6,7
TABLE 6C-2: PRESCRIPTIVE REQUIREMENTS FOR GLASS AREAS IN ADDITIONS ONLY
Maximum percentage glass to floor area allowed is selected by type, overhang length, and shading coefficient. Maximum%- oLe:> Installed % - ,~
GLASS TYPE, OVERHANG, AND SHADING COEFFICIENT REQUIRED FOR GLASS PERCENTAGE ALLOWED
UP TO 20% UP TO 30% UP TO 40% UP TO 50%
Single Double Single Double Single Double Single Double
OH-SC OH-SC OH-SC OH-SC OH-SC OH-SC OH-SC OH-SC
1'- 1.0 0'- .90 2--1.0 1'- .90 3' -1.0 2'- .90 4' - 1.0 3'- .90
0-- .86 1'- .86 0'-.70 2'- .86 1'- .70 3'- .86 2'- .70
0'- .65 l' - .65 0'- .50 2' - .65 1'- .50
0' -.45 l' -.45 0'- .40
0'- .35
SHGC or SC may be obtained from the manufacturer. Single clear SC = 1.0, double clear SC = .90, and single tint SC = .86. SHGC.;. .87=SC
TABLE 6C-3 I MINIMUM REQUIREMENTS FOR ALL PACKAGES
COMPONENTS SECTION REQUIREMENTS CHECK;
Exterior Joints & Cracks 606.1 To be caulked, gasketed, weather-stripped or otherwise sealed. V....
Exterior Windows & Doors 606.1 Max. 0,3 cfm/sq.ft. window area; .5 cfm/sq.ft. door area. v'
Sole & Top Plates 606.1 Sole plates and penetrations through top plates of exterior walls must be sealed. -vi
Recessed Lighting 606.1 Type IC rated with no penetrations (two alternatives allowed). 0/
Multi-story Houses 606.1 Air barrier on perimeter of floor cavity between floors.
Exhaust Fans 606.1 Exhaust fans vented to unconditioned space shall have dampers, except for combustion ./
devices with integral exhaust ductwork.
Combustion 606.1 Combustion space and water heating systems must be provided with outside combustion air, /
HeatinQ except for direct vent appliances.
Water Heaters 612.1 Comply with efficiency requirements in Table 6-12. Switch or clearly marked circuit breaker (electric) -/
or cutoff (aas) must be orovided. External or built-in heat trap reauired.
Swimming 612.1 Spas & heated pools must have covers (except solar heated). Non-commercial pools must have a
Pools & Spas pump timer. Gas spa & pool heaters must have minimum thermal efficiency of 78%. -'"
Hot Water Pipes 612.1 Insulation is required for hot water circulating systems (including heat recovery units). ?
Shower Heads 612.1 Water flow must be restricted to no more than 2.5 gallons per minute at 80 PSIG. ""
HV AC Duct 610.1 All ducts, fittings, mechanical equipment and plenum chambers shall be mechanically attached,
Construction, sealed, insulated and installed in accordance with the criteria of Section 610.1. Ducts in attics must be /
\of'
Insulation & Installation insulated to a minimum of R-6.
HV AC Controls 607.1 Separate readily accessible manual or automatic thermostat for each system. _..~.
GENERAL DIRECTIONS:
1. On Table 6C.1 indicate the R,value of the insulation being added to each component and the efficiency levels of the equipment being installed. All R.values and efficiencies installed must meet or exceed the minimum values
i1sted. Components and equipment neither being added nor renovated may be left blank.
2. ADDITIONS ONLY. Determine the percentage of new glass to conditioned floor area in the addition as follows. Total the areas of all glass windows, silding glass doors and glass door panels. Double the area of all non.
vertical roof glass and add it to the previous total. When glass in existing exterior walls is being removed or enclosed by the addition, an amount equal to the total area of this glass may be subtracted from the total glass area.
Divide the adjusted glass area total by the conditioned floor area of the addition. Multiply by 100 to get the percent. Find the largest glass percentage under which your caiculated percentage falls on Table 6C.2. Prescriptives
are given by the type of glass (Single or Double pane) and the overhang (OH) paired with a shading coefficient (SC). For a given glass type and overhang, the minimum shading coefficient allowed is specified. Actual glass
windows and doors previously in the exterior walls of the house and being reinstalled in the addition do not have to comply with the overhang and shading coefficient requirements on Table 6C.2. All new glass in the addition
must meet the requirement tor one of the options in the glass percentage category you indicated. The overhang (OH) distance is measured perpendiculady from the face of the glass to a point directly under the outermost edge
of the overhang.
3. RENOVA TfONS ONLY. Replacement glass needs to meet the following requirements. Any glass type and shading coefficient may be used for glass areas which are under at least a two loot overhang and whose lowest
edge does not extend further than 8 feet from the overhang. Glass areas being renovated that do not meet this criteria must be either single.pane tinted, double.pane clear or double.pane tinted.
4. BUILDING SYSTEMS. Comply when new system is installed for system installed.
5. Complete the information requested on the top half of page 1.
6. Read "Minimum Requirements for Small Additions and Renovations", Table 6C.3, and check all applicable items.
7. Read, sign and date the "Owner/Agenf certification statement on page 1.
-2-
PAUL SIERRA CONSTRUCTION
5430 - 8TH STREET
(ROOM ADDITION)
SQ. FEET PRICE
MAIN OR LIVING AREA 360 $ 40.00
OTHER AREA UNDER ROOF $ 15.00
OTHER
VALUATION $ 14,400.00
FEE SHEET $ 95.00
ADDRESS $ -
DRIVEWAY $ -
BUILDING: $ 142.50
CREDIT:
BUILDING LESS CREDIT: $ 142.50
ELECTRICAL: $ 33.92
PLUMBING: $ 47.50
MECHANICAL: $ 25.00
RADON: $ 2.40
TOTAL $ 251.32
I
SEWER'I $
WATER: $
TOTAL: $
, I
3/4"
WATER METER:I $
- f
I
TIF'S:r
99% $
1% $
: I
TOTAL: $
251.32 I
SQ. FEET PRICE
MAIN OR LIVING AREA 300 ~,~~
OTHER AREA UNDER ROOF tJ/rr
OTHER
:YAv l--. SI riaf2..14 Le>ri ~.
I )c.r~c. sf-&., SA.;
(~i-'L tf/l)UI n~^ )
4>1, b ic,t'f
...
(of.! l:rf'lW CT r~ 1J e:f
BUILDING:
ELECTRICAL:
PLUMBING:
MECHANICAL:
....
." ."
33~q~
47.50
"7 -- c....
L,..o::> .
, F+. RADON:
CREDIT: .
2.l.{~
,J"It
SEWER: ,J Jfr
WATER: J
TOTAL: v
-j
r
T.I.F1sI jl/I'
I
f-;L!Ij- 1 T::Jd r."\ j
f~GL~. ~~{()!_:Irlans
: :ic
Ar~
31EER0
CONSTRUCT I U~
IOO-.:JLOL,
FAX t.le I 2. 1 ,?:2235::~2:::
vOl t.J"::'1 i :oJ:::':;'
t
-'1."'"
,~
\) 1. ; :.J;:; ;. UC'
1:" l~ r
r; . .l.
Al'1'I..10l'UOIl' JICla ~T
CITT or t:".U>RDuD:LU
:llUIWUIG DaPAIl.~
J)A::'W! ~__. ~
PloMS ~ ~
GWN;~~I ~ tfA.~ S~.r.3. .,:;illil;J.;'ld
tlIONlti313-7B2-21 ~i
JOll AC>DI1!::.;~
:;-130 8th .3t. ZephYL'h:i.1L:;, FL
33540
Lro;U tlr:~cF.I~TlON, L&I'{S) _:D.__Ef....f_L_ BLOCJ( 120
rAl'GH 18 * II ?-6 21 .9_Q1Q..)20CO 0210
SUBDIVISION 3681 PC 1 273
jOllTAIH t'R~..l'.B;JP~'l<"l''(' ~;>.:< warJ"" ,
~Ol~l, >';;0;:';)1::0: Om;'"... COr;Sl'!\uC-rrOlO )t<AnDITIOJ/
DSIGl/ P HOVE
DALTEAA'tION
o MI'AIR
o IN~TAt.L
o DEKC::'lSjj
FHCll'O:JED t1'lr~GL f'NlU.Y /lWELLING
D(,OHM!:I\C~M,
DI11JLTI-FAHILY
o INlllJ:lTIUAL
O. Of UNITS
OSWIl+U)/G fOOL
o )o\'OIH tp. )10M!!:
o 0'11l&l\
t;lf,:;c;JU r'n Ot. O~- If-:JRK
CJ Rr.S'l'AUlWIT ~ Hwu.ra "Dr.t'MTMEHT APPROVAl.,
Nc\y bedl:'oom, bathroom, laundry room end hallway
...... "".'.: 7805;' Existing
'QVoW fOOTAGE.....:ui!) N.~..! Ht;IG1l'l'
DUIl,DntG SIZE _
f1I:~lDDI'1'IAl.1 ...~...CH 10:) l'LOT l?LNi!l , (2) Sf:"!S OF llllIUllNG PIJl.HS , OJ sa !NtP.G.t rtlroHS.
CONMERC:::A1.,. ATTAl;"1l P l ~ETS OF au I LPHIG ..UoJI::: I: 11) Sr.r r-.>lr:RCt" t'<;iffl$.
PROPl:I-l'r"t SURVEY' l'lF;Qf,lIUP FOR ALl- W!:W COH$TRUC'l'IOI(.
/"
;S IJ!JJ LDINc
~. ELJ:CTf<ICAl.
~ l'Ll1111HtO
)4 /41':,llN/IrAJ,
Oc.'\..:. LJ RC-{..!FING
PERMITS REQoES1'EO
$_~ S ~~.Q.L VIILtI.'\'rtoll O~. 'T'7rAL CON:'l1'R~}C"1'lON
__ __ AMP Sl::IN1CE
o fWIUWI. POW<;R
o lr.Sl.t.C:.
.
~
o ::nCI".LT'i
v.\L!JJ\TIOtl ~f" te<;H1;NCl),.t, :/i'Sl'''-LLA~roN
o O7ill:.1<
,;,'{['.: (,f CON:l'tR\lCTIOa: CJ !lWCI'[
)< nV,I1J~
Q :lTY.~
CJ D'l'IfE:ll
<"INl Sileo f~"OFo. l:J.r....A:t.l=~
I~ PROJECT IN f'LOOD LONE AAr....O Yf;:; X-NO
~. . , ." .... T'" .' .,"1;" ,;~t.~>f.:;;"',1 ~"'I,."",~~iC!:W"::7:J~=
~ =- :.. ,,~.,-.,- :'" ., ~~:.,.~... .~..,,_. ',: ';." ': ,; - "". "~~r<'n:",i. ..!.!;;:.'Ii'I!1,'}~1i"I. '1 .~i
~lU)U ./ ~ ,,:::--/1 /7;'/7;/ C".M~MY Paul J. Sierro. Co;~.struction lIne.
~--- h(j~~'<", C;V-c..e!..(!..(R.. stATE CEllT OR RE3IST' ref' nn?ClHO ~ 2?..,
S:CMTV . ~-. ~-:::-.u.u&:~"~'''~=~~~:.~:::~:~7:U...'U'.HU'
ok
r:L:Cenu:=.... _/ ~ Ii COMFA..'1~ BElrcDl!:1(~""'ric
..r.. ~ / STM':! CZR'l' OR I<.E~I3'1' 1# EC OQt)l8GJ
SIQ.ATURE _t-r::y' J/r.... /J~..::J/_.._ en! l'IlOCES3IN.. f
'~*....."...A.....f.......~.~I.'.. ~4~6.~..'....;.~.._....*._...,.
P1.tDoiS&Il ...-//-J t;;(i' .6tIl?AH't Ciccarello PJ umbinq
~-- ~ / ,../ ~'I'A':'E ceRr OR ~lS'1' I t-::FCQ 56935
:l1CM1'Ollf7-i.L -" ~ ~ A..f:J.J.....<~~ /~1n' PJ\OCl::'::lING .
;f .6.. .~.'4~.~.~.4~.4.'4...4......*...~.~'I.~.'.....i...*.*...~+,..
1a(."'E~ & ~'JUN Ken1;: ^_C
- \,(__ Y -- .!lTATE CT.R'I' O~ ro:GIIl~. CAe 036839
SI~l>;\.T'\JPl:L '-""'--- ..... cnr PAI)CE.qSIIlGO ~
\ -/
,,~- *_.......~~.~w....~.....c..,.,......*.....,.~...**..............~
1Jr~ ok
2')1~ 0/(
227l
Ak~cI -It) r-y
-!
5~~ (.el~~: {c..h
0TKlI:a ___.
_ CtlfolPAHY
STAT!: CaRT OR I>ll!:\OIST .
- c:.:Il':t' "I\O'~UlSIHG f
!:I(:~.A1UFl.E
.....~~...~-~~.....~~t~4.~~.&L'&!i.C.~4..4i_~...4..44~~.*y.~~~..~
..
; 111')lnc: ,,~ r'CI..~~'.. g,._i...............-_.J"'.~__....
o l>1rO 1& p~.t:son.J..:..ly kn.QlVn to me, ;.:-
o !'4C~::;' hcJ.ti ..1L')<JI...e.~_____a_,..__.".______
[~yP~ c( id~ati[ic~ti~nl
~f\d ..,t-,c.{,J c~d Odld n~t. t;akco;l." o.th.
E:ho 1. pc~.ona11y kn~w~ t~~, or
o "'t.Q hll:! pro~IJ<;"d
I ~'fl>,~bf idJronbe-ic..,;;,,;;) .'
"n<1.1~l O<11d. E>>1cl !:Qt tllir. ~~~. '.t~/-.;p/' '~_
J .//'0' 1'/., .; /'" V/. I
--....l_! ., { ,,"./...-y'l...Jf.. t-- ,..('..<(~.."\_ (.-- }.-.:.-~
3i~n~tQre of per~~:1~~n~~~d~~n~
IIdl1'oC cyp..d.'-p<:':nte~-;-~ ~t.."'P,..Q
-
'i;;;..:".. ~ _ ~_
j ..'./'i;.J".".\ DIAliA JEAN PYLANT' ........,
!;::'. 'I'...'>.i,l ".1 '.~V COI,lM.JSSION ,'''' n'
I ;...-"'.'i-:<. ,. (F"-E~ D L\. JlOl-
! "~.i.'~;.~rs;~:'" ,r;, 'I"~.. .ccmb.;~ 21, ;C02
~ ~~~.~ TrI.... N('ll.l/Y ~J"":c:. u~(Je""''''llir'- I
-~~
S!...,:;1;t3t.IJ.re c: r-e:~on. t~kirl:g aCXl...c;;wled~C"ffi;:nt
U.'I'iH: t~'p:~d, p~lnt~;j""';~-'~~--
L~onun"rcial
Addition
_ Non-Structural_ Site work
'/plumbing L HV AC
Fire Report Completed: YES / NO
(Hillsborough County Only)
. _11I>>-- .1fT
Date:
Owner:
Site Address:
Folio #:
Legal Desc. :
Work Desc.:
.~
;"'~.':"',,;o..;,_'~_"""'''''''^
.- .. ----,-------
LLC*
PAUL J. SIERRA CONSTRUCTION, INC. ~/'-C c
912 W. Martin Luther King Blvd. \::) ~ CX) Q l % 0
Tampa, Florida 33603 ~ QJ..t.- \ 3". C:Sielf'r~
Phone: 813-228-6661
Fax: 813-223-5328
PERMIT INFORMA nON COVER SHEET
7/a,3l1Q
lJeh6;Q~ --pQ_" \~{;"SOY}
$'-130 ?5~ Sr.
~ephy,hJ\5 FL
Clry Stme
II ~;2b ;;Z/ Do} 0
lo+s a l ~ ~~
P6 I r'G -.<;'-j
...L' c/ I - ( I
("f' >'V1 0\( e. ex.. ~ui f\~ "2(10 I " II i f\ (s o.rec..- <.:
kl d. I ~ IX ::>0 t add...... 16r- ~CH) J .. r Q f ~~a1; II"
33S/jO
Zip Code
I~OOO o~/o
blocK- l;?O
B1 -3 b81
/JGi~73
CHECK ALL THAT APPLY
~esidential New
Remodel /" Demolition
_ Repair
~tructural
Interior
/' Roofing
Exterior
~ Electrical
Exact Date of Fire:
CHECK ALL ATTACHED DOCUMENTS
~ Computer Work Scope -d... Floor Plan ~ Site Plan
Framing Plan I Energy Cales. Duct Layout Manual J
SE Structural Letter PJSC Structural Letter
_ Drainage Plans _ NOC
Job Value:
Contact Person:
Special Instructions:
3(,; 617
~ C!-~L - fl/5 - ~:2j'-~61
a "~ r M ~ ~ (k.~Ix&1:,
SU,fRRR
CONSTRUCTION, INC.
. Class A
State Certified
General Contractor
'CGC002980
April 26, 1999
Ms. Debbie Patterson
5430 8th St.
Zephyrhills, FL 33540
Re: Sara Gilliland
PROPOSAL
Labor and material to completely perform the following work:
Perform asbestos abatement on the siding located on back of home and on the
room addition on back of home
Remove all electric and plumbing from room addition on back of home
Demo back room addition to include roof, roof rafters, walls, wall studs, floor,
floor joist, and pilasters
Demo existing wooden deck so that a new room addition 12' x 30' can be built;
new room will be 12 LF back from existing home and built across entire back of
home which is 30 LF
Install 18 pilasters on 6' centers across new addition
Install rough plumbing for a laundry room and bathroom
Double 2x8's to make a 4x8 beam; install 3 rows of 4x8 beams 30 LF long from
the existing home out 12 LF at 6' centers; pressure treated lumber
Install2x6 floor joist at 16" centers, wrap 12 x 30 framework with double 2x6's,
four sides of outer edge of 12 x 30 frame; pressure treated lumber
Install %" pressure treated plywood on top of floor joist on 12 x 30 frame
Install 2x6 stud walls three sides of frame; walls to have a single base plate and a
double top plate; walls to be 8' high
Install six (6) common trusses and one (1) gable truss, 30' baring, 18" overhangs,
4x12 pitch with a valley kit back onto existing roof
Install CDX Y2 4-ply plywood on top of trusses and valley kit; cover with
15 lb. felt
Install four windows - two bedrooms, one laundry room and one bath room; each
to be aluminum single hung window - inill finish
912 W. Martin Luther King alvd., Tampa, FL 33603 (813) 228-6661
Statewide 1-800-409-5897 Fax (813) 223-5328
Page 2
Install 25 yr. shingles on top of felt; install FHA flashing on gable and eaves;
install valley metal in both valleys; tie new shingles into existing shingles at both
valleys
Install Y2 CDX plywood on three exterior walls; cover with 15 lb. felt
Install 2x4 interior stud walls
Frame a 12 x 12 bed room with a small hallway leading to it
Frame an 8x8 bath room, frame a 3xl2 hallway from kitchen to exterior of home,
and on other side of above hallway frame a 6xl2 laundry room; single base plate,
double top plat~
Rough-in all electric, plumbing, and air conditioning for the bedroom, bathroom,
hallway and laundry room
Install R-ll wall insulation and R-19 ceiling insulation; insulate only the three
outer walls and all ceilings
Install W' drywall on all walls and 5/8" drywall on all ceilings except in bath
room; in bath room install Y2" moisture resistant sheet rock on walls, 5/8" drywall
on ceiling, and dura rock on walls of shower area up 6 LF from floor; balance to
be moisture resistant sheet rock above dura rock in shower area to ceiling; tape
and finish all drywall
Install 3'0" x 6'8" HC pre-hung door in bedroom, bathroom, and laundry room;
install lever hardware on each door
Install hollow metal frame and metal door on exterior wall for exit from hallway;
install lever hardware on door
Install slate siding on three exterior walls of addition matching the asbestos siding
as closely as possible
Install fascia and soffit trim on new addition
Install marble sill on four new windows
Bathroom
Install ceramic tile on walls of shower 6 LF above floor - three walls
Install recessed soap box 12" x 12" in one wall
Install mud set on floor of shower; slope all four sides to center drain
Install ceramic tile on floor of shower 5x5 area
Install marble threshold at edge of shower to stop flowing water
Install ceramic towel bar in shower area on one wall outside of shower
Install ceramic tile on floor of bathroom outside shower area
Install marble threshold at bathroom door entrance
Install mirror above sink
Page 3
General
Electric as follows:
Bath room - vapor proof light in shower, light above sink, exhaust fan above
toilet, GFI outlet next to sink
Bed room - four outlets, one each wall, one overhead light
Hallway - one wall outlet, one overhead light, one exterior wall hung light at
door, one exterior GFI under above light
Laundry room - washer/dryer hook-up, hot water heater hook-up, one wall outlet,
one overhead light fixture
It is assumed that the present electrical panel will cany the above electrical needs. A sub
panel has not been included in this estimate. Will have to be added if needed.
Plumbing as follows:
Bath room - One anti scald shower valve, one slide bar, and hand held shower
wand, one shower pan, one regular toilet, one wall hung sink and single lever
faucet
Laundry room - washer/dryer hook up, reinstall water heater
Exterior - one hose bib
Air Conditioning as follows:
Bed room - new duct work tied to existing ducts with new drop in bed room
Bath room - new duct work tied to existing ducts with new drop in bath room
Laundry room - new duct work tied to existing ducts with new drop in laundry
room
New air handler and new compressor - 3-ton Trane with heat pump. Will replace
unit that presently heats and cools home
Paint interior and exterior of new addition and any existing walls affected by
construction
Install all trims for HV AC, electric, and plumbing
Install floor covering in new addition, VCT, vinyl flooring, caIJ>et or combination
of either
Clean and haul all building and demo debris
Provide plans
Provide permit
Provide supervision
Page 4
*No work other than itemized herein included in total price.
Respectfully submitted,
PAUL J. SIERRA CONSTRUCTION, INC.
-to ':# t2tL-
WayneH~
Vice President
WHA/jp
CC: Julie, Gulf Coast Community Care
PROPOSAL
The above price, specifications and conditions are satisfactory and are hereby accepted.
You are authorized to do the work as specified.
Accepted by
Date
... --',. '-/Vl~l".'.....''".... I I ,"r-... J '-'I '".~l_ ,
~.........-....-
~
~
~~
~~
~~
,
~
~~
"
~
9 . ~
~ 1,,0 - i " .
..~ .,.\_.........., .J ""~." " :..'. ' ., ~..,"-.~."".}...r :
~..,t.a...... ..........~...T"-,..... tP " ~/,r ~"r'fl _Y" }."." ~_<~~'::. 'If'-.A'
1:,lfli1,/f)!)~40(>:'t~~" ,~v .ALL,t;: .. ~~',.~::~t\',~;~~,:.
- ~ ". (P8F)'~
*)i "tV 25~a:;'OO"wIF) 50. co , f.l~
c.5' J c:J'
,~' ~
", ,.J
ai f-
D
-J
I LOT22 \/J LOT;?I
8L OI'/( 1 EO
~fr"" z ';'<t.v,
~] ',~'~ ~
\~:
I; " ~
! . .(~,. ':;1 ~~ ;\ ~
. I ',~j I';~;~. . 0 ::.:/1 ~
~ i \,~;, :,"t,::1 ~:~.': ~
I Ii < ~,\)f' ~ :)t: ~
~ "..,\.,... .
. ;."f: . ,( : ,t l .~:..
~..' t '~7" ,:;,1
~I l~'}
d 17.2'
WOOO OECX
U10JUuL;,~c:.. ,
i~iJ'" J ':::JO::! 11; J:::.>AM;
~~...--~~......
.......\~'l""ell ':IIIUI elf ._~
~~1 ~.I!q ~.IiI~"'~" __
"-" ..- .--....------...-.-----....-...-- -~,.----.. "-.........-...__ "'"--40._--
1.0'.-
Lor 23
T:' ~@
..... a::ot>
~ u.
:..-
~
~
~
~
"
~
f'~
\o~
to'
.p'
et>
~
.
c,t'
"r.~
~ 50m'(paF}
en
!'::i 15'
~
96 ~
-.... ,
~ !f}. 15.3'
~ ONE STORY
,~ g~ 1'1 FRAME
uW W RESIDENCE
~ lrI~ (\I _5~30
() 41-
t2 9.(;' 10' ~
V) .",
6'
~
10.2'
'.ci'
~
~
,~
.%
a
10.4' C)
~
~
/If): It" till
~,~
~,J~
,.\t<lt~
~ ~v
f.~9 zs' ~.
S25~Cl) ex ':- FJ
~
<::)
It) 6'~ ("r, '. ClJ('/)
01 Ii
~-:..-..;.
; ~ ;: \t'
MOSf)holt /Xl.,8m6f1')': :." ';;.:.
'-STRfET'h'_. .
. .... .
... ....
--t::._.~- - -- 8- fit
~~ 'lIlIlll.-
. _. ,
Page 1 /1
~ _ 1 lUll
-
"'@
SCALE.' I
L 0/ ,20
.......
~
~
~
EldST I rJ ~
a
<:j
~
I hereby certif
and Improvement
on this map ~
direction ?n the
on the; r.l1ormat
as noted - and t
know} edge ano',"
the Min1mum Tecb
Land.'.' Suryey 1 n$
F) Qr.:{da .. in.: ac<;'p
2 1 HH'- 6 S F 1:4"" .
Code .,/ i
PREPARED 8'!' : ~
..://10
(/" P r
Fl
~~..9'C:, VAl. J P WNLf
RA.lSEO SEAL
~~----
l4J
~
~~
~~
~,~
~
~~
""
~
f'~
\o~
to'
-F"
0(\
~
.,
~.
Co
~t,~
~
~ ,09 - ~' i . . .tP
.~ ','\..'..""".... J "',~." ':.' '. , "'.:i".'~'.~
4 ~,'"~.''''' "',..,..,""u T......., tP,' ~ II' L"'t...."f .Y" /."t' '; ~;~:1~':" ,... A
~'Q Idi~ /'PI)d ~ ~\ ~ A . "'l:;' . '~I'1H:';'t-;'\'l'~CP". ':'
~o_u,.., o~~t.,..... '-. ......",. (I,
- ~~t, '0 (P8r) . '.~~
?' 'IV 25 Da)'OO"W(F) 5t),CO' .,~
~:" ?5' ~ J ~5'
lO'~" ~
al f-
a
..J
LO T 22 V J LOT C I
BLOf( /20
llft~r ';; 3
,." q
I '.; :: 3:
'!''''If f:
r .~ ;.~.?l~\ ~ ;::~i ~
~I,I '~Hl:2;,,1~1' ~ <:~I ~
.; r" ;,.'.t." ....: 0
i j~. ~'\::'; 8 :~(~': )
~: /. Jl,i ~ .:.
, "'r: .'1'; ;:rl'.. .. "',
! ': I, ' :~::'1
~..., 7,1' ;".i
1\',.1 (fl- ,}J~'
j~ rJ\ ~ . 17.2'
ID~ ~ ...,...~~ '
M, 96.;',' -'
~[["lttq ~ PA! 15,3'
~ ~ ONE STORY
~~ . FRAME ~
'~8w ~ RESIDENCE ~
~ ~~ N _~q30
l2 '10'
Vi 9.(; z
t
. )F 0
D~ MO c'f:..'5 (/1.)6 W()()~
~~qIr\E ~D0M of- /')EC).(
~ ~ X IS
,~
.~
a
\l
~
~
..
~""".....,. .........~ au ".11 .,_.- Y ""
.~~ -~ ..........~.("'"IiI I
w_. _. .---.....0..--.___.._____4..".______..__, -...-....& . _...__~...____ .......ou.____
Lor 23
I
~ ~@
..... (1:11)
~ u.
,....
~
~
~
~
.....
6'
"
/04'
50.fXJ '(Pd F)
IlfC/(J!I lid
~,~
~~~
" \~~.;,
~ ~V
,G9 zs' ~. 25'
S25~CO X'..- FJ 50.00
(PJ tt')
~
~
It)
6'~C"r4'_ CIJI'II
.; Ilf
~-.:.-..o.
. ~. .~
"r~ :.., 2'4ospho/t. po"(lm'(1:;j: :., " "~,'a
---ti.-.-- - ---. 8- Ih . '-S FRfET-'-. .
.. . . .
Il!l" ~ T
~~_.f?"V
"l1J
...
"~
SCALI!-' I
.
1..0/20
........
~
<tS
~
ar
<.:)
~
fJRofJos E[J
tJ r:: C K 7 0 ~E:rv1A } 1.)
I hert)by certif
and ImprOvement
on this map \'j
direction ?n the
on the 'irrformat
as noted' and t
know J edge and''-
tho M'in1mum Tech
Land','Survey 1/19
F).or.:{da' in .> acc;p
21HH'.6s F I~r'
COde./ ..
PREPARED By : ~
. ..;//10
'...'" PI"
F 1
. ~tlJ>~ ~:, VAL j P
RA./ SEO SEAL
WNLE
~3/~4/1995 18:38
I::ll::lfl::l,jf,jl::ll::l
t.UWAKU t-'u::'I:.Y
1"'"1-11.:11:. I::ll
RO ~RTY TAXES AND PROPOtED OR ADOPTlD NON-AD VALORIM ASSESSMENTS
DO NO PAY. IS' IS NOT A BILL
1991
PRQPQSED AD VALOREM TAXES
o\CCOUHT NU_Il:l'l:
~l'lCIL IDOlnI'lCATlQN:
11 26 21 aelO 12000 0210
TM ...In, IWlOtftIM whIch levy property ttxn _'nit vour PI'Opefty wIn lIOOn hold
PUBlIC HEMINIII to IIdopt ~ 8nd ... ...... 'or lite nut Y'Nt. n,. JIVI'POee of theM
PU8UC HeARINGs .. to rec:eIve opInIo,. from thI...... puIlIlc Md to ......, qui....
on till ptvpoRd ... clNllll8 8Ild budget PRIOR TO T4l(ING FINAL. ACTION. bCIl taInt
8UIhortty !MY AMIND OR AlTER ... pnIpOUIe It.. _ring.
VOUII 'IlONJIITY VOUR TAXEI THIS 'UBlIC HUllING 01'1 Tttf! ....Ol'OSII:D TAlCO AHO IIUDCIn W1U YOUR TAXn TH"
TAXING AUTHORITY TAXEI L~ YEAR" "''')POllED .. "LO: ViAllII' NO IIWGeT
v..... .UlXiIl:T CHANGI IS CHAHal .. MAGI
IIAN
COUNTY 16.74 U.16 '~9~91 6130PH BOARD ROOM DADE CITY 15.54
COURTHOUSE, DADE CITY 727-147-1129
PUIUC SCHOOLS 10.13
IY STATE LAN 11 ,67 11.25 SET BY STATE LAW
IV LOCAL IDARII S.Dt 4.81 9~lS~9' 6'00 PM SCHOOL 10 RH,7205 4.11
lO'lKS ILVD,LO'LAKfS '13-996-3611
ZEPHYRHIL l S 11.11 11.11 9/14/91 6:00PM CITY HALL,5335 ITH 10.90
STREET, Z!PHVRHILLS 1l.S-711-23U
MATER RANAGEMENt 1.31 1.24 9/15/98 5101 PH TAMPA SERV OFFICE 1.11
DISTRICT 7601 HHY 301 TPA. Fl 352-79'-7211
VOTER APPROVE)
DEIT PAYM~NTS
1.61
1.52 SCHOOL aOND ISSUE SAME
TIME/LOCATIDN AS SCHOOL
1.52
TOTAL AD VALOREM
PROPERTY TAXES
41.2'
46.16
44.61
COWIIlN 1 COLUMN 2
HI qy..... ..,. PCM UPLo\HATION
,.,....... fltlI ~dtIlt ...1..........,.11 YVW~ lfellI
C'lIlIlIOIIIlt TIll CCIIIIIlet II:
(81S) t2I-f02O: (HZ) 12104310; (8fS) ..7..115
cow.,
SEe ~IE SlOE
'Oft !XI'lMATI()IlI
YOUII PRO.....,., v","UE
AI O~ JIIHIMJN l
LAST V,lIIt THIS \'tAft
26,14
26,742
Mike W.lls
Pasco County Prooertv ADoralser
MAAl(lI;T VALUe:
....IOTIONS:
26.84
" you "al YOUr ma/\61 vtlll8 ill Inaccurate. or cf~. nOl
..rtoOl fair marlalt value, eMW!l 01,1I oMo. et: PO 10... 401,
DIldo City, FL 3~&-0401. or call (352) 521-4433; (813)
129.1280; (813) 84108151.
HI.IUO YALIIe:
TAllMLI YALUE!
If 1M Property Appral""'. Offloo " unable 10 I'lIlIO/v. tn.
25, 0 a maU.r a. 10 ",ark., VIIU., you may III, a petition 'or
adlu""'.nl wltll the Value Adlu.rmenr 10.,4. P,tlllon
1 I..:. form. ar. IYlllablt In OIl( office III1d must tz.e fIItd 011 91
· "" 1,742 before; 9/1/199.
ADOPTED ANOIoR PROPOSED NON-AD VALOREM ASSESSMENTS
u( menl u..
SOLID HASTE
'/25/9' "30A" 7530 LITTLE ROAD NPR
6.30 PM 3a05~ LIVE OAK AVE DC, SOLID
HASTE QUESTIONS ONLV, 113-'.7-'123, 113-
9'6-7341 EXT 1123, 352-521-4274 EXT alZ3
1
52.00
52.0
'Your fin-'... bl. m~ ~,*In non-a4 vaIoI'eIll ....Mm_ whlch mey rot be ,.~ on '"Ie 1lOl1Ce.14ICII ee 1I:I5"""'InI"O' roaae. fire. e-rolQ, TOTAL
d11POU1. IIlIhllng. dtlIinaoe. WI"'. ......r, or """t lI_.nmen'al ""'icn ."" la-" wr.lch may be Ievled by YOU' COUnty. cily. o. aow _i<<I
d1'\Itc:l,
52,0
'"1111I11",,,..,11,.,...1111,.,..,1111...1..,,11 ,I, ',.,1.1.1
'ATTfRSOH DEIORAH N
PO IDX 839
ZEPHYRHIllS FL 33539-0159
RDLL"'R HX
TM~.m~~LA$T-YEAR THIS-YEAR
'30ZH H ~OZH H
m"""""HYIHIl LS
PI 1 PG 54 LOTS 21 I 22
.LOa 120
OR ~"1 PO 1273
~,.
00Z560