HomeMy WebLinkAbout00-9403
BUILDING PERMIT
CITY OF ZEPHYRHILLS
(813) 788-6611
Permit
09403'
'-(-!Iii 00
Date
r I/b~
')0.--
BUILDING
so,~
ELECTRICAL
PL~ING
MEC~NICAL
Sewer Conn
Water Conn:
Property Owner: P; Z 'f: Co" . ~t .
Job Address: b ~ 4""& 6", U g I vd.
Parcell.D, # 6~- :2b,-JI. 0010- ,~" Ou- 0010
Water Meter:
T,I.F:s:
Zoning: Energy Code: Radon Gas:
Description of Work --l')o It" S:9 i\ ~ we:. t \ ~5 ~
NO OCCUPANCY BEFORE C.O.
FINAL
S~/C>~8d
DATE
Complete Plans, Specifications and Fee Must Accompany Application.
All work shall be performed in accordance with City Codes and Ordinances.
c.o.
Inspector
DATE
A?
City License Registration #
State Certified License#
Pe,m;t Fee ~ 00, ~ ~
- Signature -,iJJ t.JL.(.J:7 A rJ
Company
Address
~ Telephone II ~ 1.03 -., /" 4l../ - 3~ 2 I
Valuation or
Contract Price
'3 ODd. ~
BUILDING ~l)
ELECTRICAL 3&b
PL MBING
ME HANICAL
Ftr. .J.(---'2J- fPC) ~ R-
Pre SLB
Lintel
FRM.
Insul. CL
WL
Driveway
Tp. Servo
Rough In
Meter Can
Const, Pole
Pool
Pre-Meter
Final
~ S~<f-GtJ ().~
SLB
Tub Set
Water
Sewer
Final
Breakers
Ducts Insl
Compress r
Final
REINSPECTION FEES: When extra inspection trips are necessary due to anyone of the following reasons, a
charge of Fifteen and 00/100 Dollars ($ 25.00) shall be made for each trip for each trade:
a, Wrong Address
b. Condemned work resulting from faulty construction.
C. Repairs or corrections not made when inspection called,
d, Work not ready for inspection when called.
e. Permit not posted on job site.
f. Plans not at job site.
g. Work not accessible.
The payment of inspection fees shall be made before any further permits will be issued to the person owning
same.
. ~~~ ~~
~;>D- ,
D t i- i \7--, C::::> \(fl"';)
Co~'-f<6 ~-(1LL; $t.v' Jj
---~ ,
~~) ~~iJ
SQ. FEET PRICE
MAIN OR LIVING AREA
OTHER AREA UNDER ROOF
OTHER
BUILDING: J;'-- :;;, ~
'./~ .
ELECTRICAL: ~- ';:;)':::::>
?,
PLUMBING: fJI/1
, I'
MECHANICAL:
RADON:
CREDIT:
1/
/'
SEWER:
WATER:
TOTAL:
I
T.I.FSI i JJj;r <::, I
---rs- -r#-- Sl6, =
. <}0--\.Y
\.Y ~ \.b~S
~i~/i. 5t~~
~ "=' ~~ GAtt r?J-, '( I:] .
LC. lid viI ( 6t? )
~
P1L2-f\- J./-\Jl . ~.-..
SQ. FEET PRICE
. MAIN OR LIVING AREA
OTHER AREA UNDER ROOF
OTHER
BUILDING: 25~ DC
ELECTRICAL: 25.<'0r.::.
PLUMBING: ;J J Il.
MECHANICAL: /
RADON: I
CREDIT: ~
SEWER: JJ~
I
WATER: I
TOTAL: J
I
T.I.F'sl ~h--.
11, ~~
r-f c:rJ4L- :;-0, <~
I
OWNER'S N
APPLICATION FOR PERKIT
CITY OF ZEPIlYRlIlLLS
BUILDING DEPARTUENT
i~/()J
JOB ADDRESS
LEGAL DESCRIPTION: LOT(S) O1io.th;ct BWCR
PARCEL 1.0.' D~-dLQ-d I-COlD -l.J~- CUI 9
SUBDIVISION
(OBTAIN FROM PRO~ERTY TAX NOTICE)
WORK PROPOSED: New Construction Addi tion -.ftlteration ~epair _Install
~ign 7,;:ve .
_De.olish
PROPOSED USE: _Single Fallily ----111 F _, of Units _HIli
" _eo..ercial _Indust. _Swu.. Pool _Other
RESIDENTIAL:
COHHERCIAL :
--"o~auci\"'t .. HoaUh Ik!~"'ont ~ppcoval
DESCRIPTION OF WORR:lJ.Q1.Q(OiQ) I J,L StCfn
BUILDING SIZE: X ,] 1 ~O Square Feet. Height
ATTACH (2) PLOT PLANS & (2) SETS OF BUILDING PLANS & (1) SET ENERGY FORMS.
ATTACI (3) SETS OF BUILDING PLANS & (1) SET ENERGY FORMS.
PROPERTY SURVEY REQUIRED FOR ALL NEW CONSTRUCTION.
/ BUILDING
$ c9 CCO~
I
PERMITS REOUESTED
Valuation of Total Construction
_ELECTRICAL
AttP Service
Florida Power Corp.
W.R.E.C.
----1IECDAIIICAL
$
Valuation of Mechanical Installation
---..J'LutlBING
GAS
ROOFING
SPECIALTY
TYPE OF CONSTRUCTION: ~loclt _Fralle _Steel
Other
FINISHED FLOOR ELEVATIONS:
FT.
IS PROJECT IN FLOOD ZONE AREAl
YES NO
..........................................
Bin IllER
cotIPANY I '{ I e.. Si
State ert. or Regis'. .
Cit:y License Regist:ration
............................
COHPANY Yi\l.lE- SI~S
Sta e Cert. or Regist.' E:5-0~/?J
ty License Registration ,
.................................
Signature
PLUMBER
Signat:ure
COMPANY
State Cert:. or Regist. ,
Cit:y License Registration ,
..........................................
ItECDAIIICAL
COMPANY
State Cert:. or Regist. t
City License Registration ,
..........................................
Signature
OTHER
COMPANY
State Cert. or Regist. ,
City License Regist:ration ,
.............~............................
Signature
APPLICATION APPROVED BY
PERMIT OFFICER.
CONDITIONS OF PERMIT AFFIDAVIT
. A.. NOTICE OF DEED RESTRIC'fIONS
The undersigned understands that this perilt .ay be-Bubject to "deed restrictions" which .ay be lOre restrictive than City
regulations. The undersigned assUles responsibility for co.pliance with any appli~able deed restrictions.
B. UNLICENSED CONTRACTORS AND CONTRACTOR RESPONSIBILITIES
If the owner has hired a contractor or contractors to undertake work, they .ay be required to be licensed in accordance with
state and local regulations. If the contractor is not licensed as required by law, both the owner and contractor .ay be
cited for a .isdeleanor violation under state law. If the owner or intended contractor are uncertain as to Ihat licensing
reguire.ents .ay apply for the intended work, they are advised to contact the City of Zephyrhills Building Deparllent, (813)
788-6611.
FurtherlOre, if the owner has hired a contractor or contractors, be is advised to have the contractor(s) sign portions of the
"Contractor Sections" of this application for which they will be responsible. If you, as the owner sign as the contractor,
you are indicating that you, rather than the cont[~ctor, are responsible for the work. If the contractor wishes you to sign
as contractor that .ay be an indication that he is not properly licensed and is not entitled to perlitting privileges in tbe
City of Zepbyrbills.
C. TRANSPORTATION IMPACT FEES AND UTILITY CONNECTION FEES
D. CONSTRUCTION LIEN LAW (ClrnPTER 713, FLORIDA STATUTES, AS AMENDED)
I certify tbat I, the applicant, have been provided with a copy of "Florida's Construction Lien Lal - Ho.eowner's Protection
Guide" prepared by the Florida Deparllent of Agriculture and Consu.er Affairs. If the applicant is so.eone other than the
"~fOer", I certify that I have obtained a copy of the above described docUlent and pro.ise in good faith to deliver it to the
"olner" prior to COllenCelent.
E. CONTRACTOR'SjOWNER'S AFFIDAVIT
I certify that all the infor.ation in this application is accurate and that all work lill be done in co.pliance with all
applicable Jaws regulating construction, zoning, and land deveJoplent.
Application is hereby lade to obtain a perlit to do work and installation as indicated. I certify that no work or
installation bas cOllenced prior to issuance of a perlit and tbat all work will be perfor.ed to .eet standards of all laws
regulating construction, City codes, zoning regulations, and land develop.ent regulations in the jurisdiction. I also
certify that I understand that the regulations of other governtental agencies .ay apply to the intended work, and that it is
.y responsibility to identify wbat actions I .ust take to be in co.pliance. Such agencies include but are not li.ited to:
· Deparllent of Envirofilental Regulation - Cypress Bayheads, Wetland Areas and Envirofilentally Sensitive Lands,
Water/Wastewater Treallent
t Southwest Florida Nater Hanagelent District - Wells, Cypress Bayheads, Wetland Areas, Altering Watercourses
t ArlY Corps of Engineers - Seawalls, Docks, Navigable Vaterways
t Depaltlent of Health' Rehabilitative Services, EnviroOJental Health Unit - VeIls, Vastewater Jreatlent, Septic Tanks
t US EnviroOJental Protection Agency - Asbestos abatelent
I also certify that, if fill .aterial is to be used in Flood Zone "A" or "A,etc.", it is understood that a drainage plan
addressing a "co.pensating vol Ole" will be sub.itted whicb is prepared by a professional engineer registered in the State of
Florida prior to perlit issuance.
A per.it issued shall be construed to be a license to proceed with the work and not as authority to violate, cancel alter, or
set aside any provisions of the technical codes, nor shall issuance of a per.it prevent the Building Official frOl thereafter
requiring a correction of errors in plans, construction, or violations of any code. Every per.it issued sball becOle invalid
unless the work authorized by such per.it is cOllenced within six IOnths of issuance, or if work authorized by the per.it is
suspended or abandoned for a period of six IOntbs after the ti.e the work is cOllenced. One 90 day extension of tile, JaY be
allowed for the per.it with fee charge of $15.00. The extension shall be requested in writing to the Building Official. An
approved inspection .ust be logged during each six IOnth period, or tbe project will be considered abandoned.
NARNING TO OWNER: YOUR FAILURE TO RECORD OTICE OF COHHBNCRHENT HAY RESULT IN YOUR PAYING TWICE FOR IHPROVE
PROPERTY. IF YOU INTEND TO OBTAIN FINAN NG CONSULT VITH YOUR LENDER OR AN ATTORNEY BEFORE RBCORDING YOUR
COHHRNCRHENT. JOBS UNDER $2,500 IN VAL NOT NRED TO RECORD AND POST A "NOTICE OF COMMENCEHENT".
STATE OF FLORIDA
COUJn'Y OF
The foregoing instrument was acknowledged
before me this , 19____ by
STATE 0 FLORIDA
COUNTY OF
The foregoing instrument
before me this
was acknowledged
, 19___ by
who is personally known to me or who has
produced
as identification and who did/did not
take an oath.
who is personally known to me or who has
produced
as identification and WhD did/did not
take an oath.
(Signature)
(Signature)
(Name Typed, Printed or Stamped)
NOTARY PUBLIC
(Name Typed, Printed or Stamped)
NOTARY PUBLIC
OWNER'S N
APPLICATION FOR PERMIT
CITY OF ZEPIIYRlIlLl.S
BUILDING DEPARTMENT
L(~(~
BI:J -85~-ijLJ 20
~. J'!J(p2,L,
JOB ADDRESS
LEGAL DESCRIPTION: WT(S) ClLU1c:mcY BWCR
PARCEL I.D.,02-2(0- 2/-0010-0':XcoO-CO/t;?
SUBDIVISION
(OBTAIN FROM PRO~ERTY TAX NOTICE)
WORK PROPOSED:_New Construction ---^ddition ---^lteration ~epair _Install
V Sign ---"ove _Deillolish
PROPOSED USE: _Single Faaily ----11/ F _' of Units _M/H
" _~ercial _Indust. _Swia. Pool _Other
~estaurant &: Health Departllent Approval /l L _. 11 .1)
DESCRIPTIOR OF IIORK:J1rWn_Q..t~ (2) fJ0io ~ ~. UOh\JYWIcfJri:t:v.D
BUILDING SIZE: X , J 1?J 0 Square Feet, Height
RESIDENTIAL:
COMMERCIAL :
ATTAQI (2) PLOT PLANS &: (2) SETS OF BUILDING PLANS &: (1) SET ENERGY FORMS.
ATTAQI (3) SETS OF BUILDING PLANS &: (1) SET ENERGY FORMS.
PROPERTY SURVEY REQUIRED FOR ALL NEW CONSTRUCTION.
~UILDING
~ COO ~V
$ I
PERMITS REOUESTED
Valuation of Total Construction
~LECTRlCAL
AttP Service
Florida Power Corp.
W.R.E.C.
--1fECllARICAL
$
Valuation of Mechanical Installation
_PLUHBING
GAS
ROOFING
SPECIALTY
TYPE OF CONSTRUCTION: ~lock _Fraae _Steel
Other
FIRISHED FLOOR ELEVATIONS:
FT.
IS PROJECT IN FLOOD ZONE AREA?
YES NO
..........................................
Signature
COI\FARY Vi ~ Ie.. 6,~ n 5
State Cert. or Regis . . f;S- oooc:o ,3 "
ity License Registration . '?)'X(~'J Ii (J
.........................
BUILDER
COHPANY I), Y I e S,Cj() 6
State Cert. or Regist. . ~S- 0000013
City License Registration .
...................................
PLUtlBER COMPANY
State Cert. or Regist. .
Signature City License Registration ,
..........................................
HECllARICAL COMPANY
State Cert. or Regist. f
Signature City License Registration'
..........................................
OTHER COMPANY
State Cert. or Regist. ,
Signature City License Registration ,
.............~............................
APPLICATION APPROVED BY PERMIT OFFICER.
CONDITIONS OF PERMIT AFFIDAVIT
A. . NOTICE OF DEED RESTRICTIONS
The undersigned understands that this perlit lay be subject to "deed restrictions" whicb lay be lOre restrictive than City
regulations. The undersigned as sOles responsibility for cOlpliance with any appli~able deed restrictions.
B. UNLICENSED CONTRACTORS AND CONTRACTOR RESPONSIBILITIES
If the owner haa hired a contractor or contractors to undertake work, they lay be required to be licensed in accordance with
state and local regulations. If tbe contractor ia not licensed as required by law, both the owner and contractor lay be
cited for a liadeleanor violation under state law. If the owner or intended contractor are uncertain as to what licensing
reguirelents lay apply for the intended work, they are advised to contact the City of Zephyrhills Building Departlent, (813)
188-6611.
FurtherlOre, if the owner has hired a contractor or contractors, he is advised to have the contractor(s) sign portions of the
"Contractor Sections" of this application for which they will be responsible. If you, as the owner sign as tbe contractor,
you are indicating that you, rather than the contr~ctor, are responsible for the work. If the contractor wishes you to sign
as contractor that lay be an indication that be is not properly licensed and is not entitled to perlitting privileges in the
City of Zepbyrbills.
C. TRANSPORTATION IMPACT FEES AND UTILITY CONNECTION FEES
D. CONSTRUCTION LIEN LAW (CHAPTER 713, FLOHIDA STATUTES, AS AMENDED)
I certify that I, the applicant, have been provided with a copy of "Florida's Construction Lien Law - "oleowner's Protection
Guide" prepared by the Florida Deparllent of Agriculture and Consuler Affairs. If the applicant is sOleone other than the
"b.uer", I certify that I have obtained a copy of the above described docUJent and prolise in good faith to deliver it to the
"owner" prior to cOllencelent.
E. CONTRACTOR'S/OWNER'S AFFIDAVIT
I certify that all the inforlation in this application is accurate and that all work will be done in cOlpliance witb all
applicable law8 regulating construction, zoning, and land developlent.
Application is bereby lade to obtain a perlit to do work and installation as indicated. I certify that no work or
installation bas cOllenced prior to issuance of a perlit and that all work will be perforled to leet standards of all laws
regulating construction, City codes, zoning regulations, and land developlent regulations in the jurisdiction. I also
certify that I understand that the regulations of other governlental agencies lay apply to the intended work, and that it is
IY responsibility to identify what actions I lust take to be in cOlpliance. Such agencies include but are not lilited to:
· Deparllent of KnviroDlental Regulation - Cypress Bayheads, Wetland Areas and EnviroDlentally Sensitive Lands,
Water/Wastewater Treatlent
· Soutbwest Florida Water Hanagelent District - Wells, Cypress Bayheads, Wetland Areas, Altering Watercourses
I ArlY Corps of Engineers - Seawalls, Docks, Navigable Waterways
I DepartJent of Health , Rehabilitative Services, BnviroDlental Health Unit - Wells, Wastewater freatlent, Septic Tanks
I US InviroDlental Protection Agency - Asbestos abatelent
I also certify tbat, if fIll laterial is to be used in Flood Zone "A" or "A,etc.", it is understood that a drainage plan
addressing a "cOlpensating vol Ole " will be sublitted whicb is prepared by a professional engineer registered in the State of
Florida prior to perlit issuance.
A perlit issued sball be construed to be a license to proceed witb the work and not as authority to violate, cancel alter, or
Bet aside any provisions of the technical codes, nor shall issuance of a perlit prevent tIle Building Official frOl tbereafter
requiring a correction of errors in plans, construction, or violations of any code. Kvery perlit issued sball becOle invalid
unless the work authorized by such perlit is cOllenced within six IOnths of issuance, or if work authorized by the perlit is
suspended or abandoned for a period of six IOnths after tbe tile the work is cOllenced. One 90 day extension of ti.e, laY be
allowed for the perlit with fee charge of $15.00. The extension shall be requested in writing to the Building Official. An
approved inspection lust be logged during eacb six IOntb period, or tbe project will be considered abandoned.
WARNING TO OWNER: YOUR FAILURE TO RKCORD A NOT CE OF COKHKNCEHKNT KAY RESULT IN YOUR PAYING TWICK FOR IMPROVKMKNTS TO YOUR
PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, NSULT WITH YOUR LHNDER OR AN ATTORNEY BEFORK RBCORDING YOUR NICK OF
COKHENCKHKNT. JOBS UNDER $2,500 IN VALUK T NEKD TO RBCORD AND POST A "NOTICK OF COKHKNCKHKNT".
STATK OF LOR IDA
COOO'O
The foregoing instrument
before me this
was acknowledged
, 19____ by
STATK F FLORIDA
COUN OF
The foregoing instrument
before me this
was acknowledged
, 19_____ by
who is personally known to me or who has
produced
as identification and who did/did not
take an oath.
who is personally known to me or who has
produced
as identification and'who did/did not
take an oath.
(Signature)
(Signature)
(Name Typed, Printed or Stamped)
NOTARY PUBLIC
(Name Typed, Printed or Stamped)
NOTARY PUBLIC
INCORPORATED
2930 DRANE FIELD ROAD · LAKELAND. FL 33811 · (941) 644-3521 . FAX (941) 644-3524
DIXIE
SIGNS
April 06, 2000
To Whom it May Concern:
This letter is to authorize Dee Howard to apply for and
pick up sign permits for Pizza Hut located at 6548 Gall
Blvd. in the City of Zephyrhills for Roger A. Snyder,
Florida State Certified Electrical Specialty Contractor
license #ES 0000073.
Dee has authorization to act on my behalf for the above
referenced address.
Ro er A. Snyder
P esident
Date:
OFFICiAL NOTARY SEAL
Di).. ;-.Ji:: ,_ !"i:,SV ACiL
N'el:" A!{"" F~JFf.Jr :::7lt'"tf. C;Ff-1IlJRIDA
t :\:., t,:,"':/~ i.~ :- ~'-" ~,.: ~<(' c()r~ an-~:.~
; ...~
\.-.,.",~..
COMMISSION EXPIRES
Dedicated to Quality Since 1939
nb. j,illllU iU,)(IAIVi
~LA)liL1Nt
110, 1420
r, 2
"S:
PIzza Hut ot Amlric:a. Ir1cJ12230 Race Track AoadIl'lIrT1JB. Aorid~ 3362M'hore: (8131 854-44m1'e/ex:- (813) f355-0542
To Whom It May Concern:
This lener authorizes Dixie Signs, Inc., as our licensed sign contractor to secure permits,
variances, and performs sign installations, and removals at:
Pizza Hut # 622081
6548 Gail BI\ld.
Zephyrhills, FL. 33539
~~
Name I Title
I'~f'>'~';
7'
L: c-t~~
D~.. -J~~
oaryP
,-$.*\f~~;;., C. AGELADELlS
~./,i!J>."~.~~~ MY COMMISSION # CC 767427
~~~~: EXPIRES: June 19,2000
".9f"t:i..' ... Bonded Thru Notary Public Underwritors
County of /?;h.1..ff ~.
Stateof {.l()h~:/--
My commission expires ~ /1
acs-n
r
m
" (P ~~~~~~ii~~~ G\
l> l>
~ 0 ~o .Z~ -i& ~
m 11 (j)m:t:~-t-t~ 2'
r- l> ~~m~~~r-_~t: r
o ~ -l~e~t;OZi' i"
'. m ~~il--liI~~~~
6 r 0
'" ()
~ 2 ~~ ilIl~~~~~ffi m
I -i
~ 1> 1: l> ~ .. ::t ... '" ~ (J)
I - ~-i~"'-tl>(Jl~.(Jl
6 ~ r~ -l~~~ :q
~ 6 ~~i~m~i~i~~ ()
6 U1
I (JI ~
~ 1)
~~-l.~~~~i31 -
~ ~ 1)
I (p ~ ';~el i -to
a :I -f
ij ~ ~~~ ,m ::tit~i:! -
~ti&l"-I;"~;~2 ~
~ -i-a!'ig&~ ~ ~
(JI ~ .- I .-t
r ~a~l!~~~~tiI'~
m
(p ~iD--.~o..-t 1-(",
~
a~!~i~~~ii~
ill-t ~nt(C :iF -,.
1) ~~ii!i'a/!:;t"'-I
-f _-t-( 8l>0 I
~"'~~I~ -t~
~ it 1>- i\ii~~~-l..~2~-l
~ ~ ~ ~~iO~~!,-~~~
~ ~ ~'" ~l>1;'" ~
~ 0 - ~~:,; -I .l~ii
UI .. ~
6 .Er i -I'
. m~~ -(~-
\i ~~t: l> !!l ~
ill
~ --f ~In ~
J>. . r
~
OJ
,
1) C
m r
(j)
1>
-f
-
0
Z
EPARED. REPRODUCTIONS, CHANGES OR ASSIONWENTS ARE ..ROHI.ITED.
. ~- II
__I
eo
3'" -m )
~x -
- "
~j !!l~ !i '" (II
.., ~! i -I
~:!! ~ ~
-1m eit
I () ~ ~~ R-I III ~
~~ l>~ ~
2a ii1 z //
I ~~ m~ u J //
~ //
)>r -./
~ ..........
III 20' - 4"
"-
I I Qrv
I I
I I
I I
I I
I I
I I
I I
I ,
I I
I I
I I
~] I I
~~ I I
-I _
S 01' 41' cZlcZl"e
l0cZl,cZlcZl
COVER ENGINEERING, INC.
w. R. COVER, P.E., P.L.S.
2011 AIRPORT ROAD
LAKELAND, FLORIDA 33811
PIZZA HUT
INPUT DATA
HEIGHT TO SIGN CENTER - AVERAGE
POLE & SIGN AREA:
FOUNDATION WIDTH:
FOUNDATION LENGTH:
FOUNDATION DEPTH:
SOIL BEARING:
(863 )682-1620
20.41 FEET
121.55 S.F.
8.00 FEET
5.00 FEET
4.00 FEET
1500.00 P.S.F.
STA1~TIARD BUILDING CODE:
INPUT
GUST VELOCITY TABLE 1606.2A (100 MPH)
USE FACTOR TABLE 1606
FORCE COEFFICIENTS TABLE 1606.2E
PSF
30.10 (pSF)
1.00
1.20
\VL"'TI LOAD:
36.12 P.S.F. (CALC)
CALCUAL TIONS:
OVERTURNING ,MOMENT:
101549.63 FT.-LBS.
RESISTING MOMENT:
159686.40 FT.-LBS.
159686.40 FT.-LBS. >
101549.63 FT.-LBS. CHECKS OK
\VL"ID FORCE
l\IOMENT AT BASE
4390.39
89607.78
SUPPORT POST
SECTION :MODULUS
1.00 10.5" X 0.368" PIPE
32.78
COJ\lIPUTED BENDI1~G STRESS
32803.34 P.S.I.
ALLOWABLE BENDING STRESS
33,000 P.S.I.
DATE: 3-28-00
COVER ENGIl'iEERI1~G, 11~C.
2011 AIRPORT ROAD
LAKELA1"ID, FLORIDA 33811
(863)P)t620 ~
-4/ ~ ., ~ ~.
W. R COVER, .E. #7734
II
62hID
/ft!;0VEIt J
- NGlNEERINfJ
~NC 2011 AIRPORT ROA .
LAKELAND, FL 33811
PHONE: (883)882"8 II
FICIrIcIa BuslI;~" /111, EB,OOO 1.7
I HEREBY CEFlTIE:Y: Thallhe
construcllon plans shown
lIereon are In compliance wlllt
8ecllon , 606 of the' 997
Edition of the Standard
BuUcllng COde and 1 '0 MPH wind .
J
qlQl1
I
M: ~~
W. R. cova.. P.E.. nn.
MAR 2 8 200l
r-l~5/~1l--i
P~oJ
Htd
qJ In
I
!O'
81/c911 PYu
"
I '31 51/~
~
RiockbQOJle.t
- I
Jtl
'\
10 l/:J. /l
P L(l-0
"2' + 4-" eDi".~
4-eA. \" x. ~
rtD. ), LlIlIl) II): IIJAM
rLA)lllJIH
NO, 1420
2
$:
. PIzza Hut of Americ:a, Ir1cJl223Q Race Track AoadIT~. Aorida 3362M'l1one: (813) 854-442Me/ex:- 18131 ~42
l
To Whom It May Concern:
This letter authorizes Dixie Signs, Inc_, as our licensed sign contractor to Secure permits,
variances, and perfonns sign installations, and removals at:
Pizza Hut # 622081
6548 Gail Blvd.
Zephyrhills, FL 33539
~/
Name / Title
;'a~/'/r';
7'
~ ~0C7~
1/
D~~OAiJ~
oaryp
.,~1A\r.~o;;;.. c. AGELADELlS
f'(~'\~ MY COMMISSION # CC 767427
~"~~'; EXPIRES: June 19,2000
"~,9r..i:i.'" m Bonded Thru NOlery Public Underwril.'s
countYOf:?tJLL.if ~'
Stateof {-lOhr~
My conuni.,ion e"Pire, ~ 11
a-vn
" (p
l> l>
~o
m 1)
r l>
o ~
'. m
~ r
..., ()
~ ~
I -i
~ l>
I -
6 iji
~ ~
6\1'
I \J'I
~ 1)
~ ~
I (p
~ :I
6 ~
~
r
m
(p
~
~ it
~ @
~~
~ 0
\J'I ,.
&
1)
l>
~
-
~
--I
l>
OJ
c
r
l>
--I
-
()
Z
.
\i
ill
~
~
~
l)
m
(p
~~~~~~i~~~1
I:oa .ZI: -i~
(pm:r:~-f-fl o~
~f;m~~~~_~I:
-iil~!!EO~' ~m
~~~a~~iI~~~~
~~~iIIl~8~~;ffi
rI:l>m..~~ "1...."1
-<-i~;!-il>(Il~~(IlO
~~ -fffl~~" :-~
e~~~~~-'~~~~
l> -< ~m QC ~;J.:r:~ ~
~~l)i~~ l>it11l
~~~ .i~~~ 61
~-...,~ffif~i...,i~
~~~&~-<~~;~2
~~~~g~~I~!~
~~~~~~gBI1t,i
~il1-",,~o"'-f~!-<11I
a~~~i~i~iB~
fR-fm~nI~~ZI=~~
~ffl;z:i!i'6~;tCJl~-<
-ifi~-i-<(\Ql>O I
~11I~~J~e.-f~ ~
~i~t~-i<>~!Ptl-i
~~iOQ~~--8~~
-f""~ ~l>l>-'~~-<
~~I;; -< ~k~~i
J=r ~ nlRi-<-
m ~ ~ ~ ~ .
i~:r: l> !!l ,
~In ~ ~
. r
r
m
G\
J:>.
r
o
m
(J)
()
~
-
1)
--f
-
2
[PARED. REPRODUCTIONS. CHANGES OR ASSIGNWENTS ARE ~ROHI.ITED.
1- &. II
.._I
~...r~ ~ ' \. bi'>
l 0 l n -,.., uS ~u....-- c::, t
('I(U'J\ D~~...x> \ \1
~O"\' 5 0" 41' 00"E
100,00
CP
~ / /
/ /:..
~ ./,/ "
$: / / ~
Jz /~~/ ~11
/ / ~~
_.~/ 2
I I
I I
I I
I I
I I
I I
I I
I I
I I
I I
I I
I I
I I
I I
I I 2.3'-6 112"
I I
I I
11\
I I
I I
I I '
I I
I I
I I
I I
I I
I ! I
t:3 J:
~ '= ~ I I
=..,u I I
~
11 I I
; I I
11 I I
I I
I I
I I ~
I I ~
I I ~
I I Z
, I
I
'"
-m j
~~ "
-f~ i:
iI~ -f
rep g
R-f II
~~
o
::1-"
~J
~J!
eit
~~
~ot
J>.o
iI~
J>.r
'"
~
m
ep
-im
I 0 ~
I ~~
zo
~
~
m
.'" 11
..J -
~~
-i
OJ:
-it:
J>.-f
r
CP
:n
\II
CP
~
-.,
~
rri
c4D
..,
~
"
j
~
i1I
o
~
r
t:3
~
I
c4D
20'-0" T"rP.
'"
.
!I
~
1:
J>.
r
-i
11
J>.
<::
~
\
/
/ /
/ ,/
/ ,/
20'-4"
~
~
16'-0"
:::i
"'CP
1:11
J>.l>
ohl
-CP
~ .
11~
~
,
COVER ENGINEERING, INC.
w: R. COVER, P.E., P.S.M
Florida Business No. EB-0001974
ENGINEERING-SURVEYING
2011 AIRPORT ROAD
LAKELAND, FLORIDA 33811-1020
(863) 682-1620
FAX (863) 683-2546
March 22, 2000
Engineering calculations for PIZZA HUT wall sign.
Design shall be based on 110 mile per hour wind loadings.
Table 1606.2A of the SBC shows that the loading for 110 mph winds at 15 feet height is 24.7 psf
Allowable shear on a 1/2" bolt = 1963 pounds
Load on sign -1.2 x 1 x 1.08 x 17.19 x 24.7 = 550 pounds
SHEAR IS NOT A FACTOR
Withdrawal on a 1/2" x 2" lag bolt = 390 pounds
Withdrawal on sign = 1.2 x 1 x 4.65 x 17.19 x 24.7 = 2372 pounds
Number of fasteners required = 2372/390 = 6.08 say seven fasteners.
It is recommended that a minimum of EIGHT (8) fasteners be used.
COVER ENGINEERING, INC.
~
)
)
55 7/8
(REF)
.
~
..-
....
:>
J
PLASTI-L1NE, INC
623 E. EMORY ROAD, P.O. BOX 59043
KNOXVILLE, TN 37950
MOUNTING SPECIFICATION FOR:
PIZZA HUT
USE OR REUSE OF THIS DOCUMENT FOR OTHER LOCATIONS IS
STRICTLY PROHIBITED WITHOUT APPROVAL OF ENGINEER,
SIGN: W-80
WINDLOAD: 110 MPH
206 5/16 (REF)
~-
SIGNSPFCIFICATIONS
1. LAMPS: 131~)j F18T12\CW\HO
F24T12\CW\HO
F30T12\CW\HO
F48T12\CW\HO
~ (1) F72T12\CW\HO
(2) F84T12\CW\HO
(3) F96T12\CW\HO
2. BALLAST: (1) JEFF 256-672 4A
3. VOLTAGE: 110 VAC
4. TOTAL CONN. LOAD: 8 AMPS
5. CIRCUITS: (1) 20 AMPS
6. SERVICE SIGN BY: REMOVING FACE
7. LIFTING WEIGHT - CRATED: 203 LB
UNCRATED: '145 LB
- ------ - --- ------------------------------------------------------------------------------------------------------------------------
- ------ - --- ------------------------------------------------------------------------------------------------------------------------
REV DATE INIT E~N
PROPERTY OF PLASTI-L1NE,INC
NOT TO BE DUPLICATED.
TOLERANCES:
DESCRIPTION OF CHANGE
UNSPECIFIED RADII
==.015 R
ALL DIIoIENSIONS ARE iN INCHES UNLESS OTHERWISE SPECifiED
.xX=:!:.03 .XXX=:!:.015 ANGLES=:!:1.
---:::>
/&;MR
. E Na/KEER/NII
tJNC. 20" AIRPORT I
lAKElANO. FL:
PHONe: (883}5S
florld. 8<l5i,;o,'" No, E!l4
I HEREBY CERT~: That I.
COnslruction plans shown
I:oroon a,e i" compliance 'N
SecUon leOe ollhe 1997
Edition ollhe Standard
'?;~
W. R, OO'w'E". P.E,. .173-
Di\W ~ ft..~c
P /N: 00-00-006-3290
PLASTI- LI N E, I Ne.
P.O. BOX 59043
KNOXVKLE, TN 37950-9043
T.R.M. DWG.BY: T.R.M. CH'K BY:
NTS DATE: 10 19 99 DATE:
DSGNR:
SCALE:
DESCRIPTION:
WALL HOLE PLACEMENT GU
CUSTOIlER: PIZZA-HUT W-80 WALL S
SHT 1 ,OF 3 DRAWING NUMBER: B 2289 '
86 13/16
77 3/16
...
I"
.... .... --....
,
\
58 13/16
...
........---~
\'
I
/
)
"
( /
____.I
-----
"'-_....~........
I
"
/
'\
/
I
I
I
I
" '"
y"
24 13/16-
...
'" " "
'...-/
...--- -
"
I
~
,.--- ...
,," ",
/ ---
... ..--- - -
"- -- '"
,
I
I
-
a
a
--
I
,I 13 23/32 /
/ I I ~ ELECTRIC CONNECTION /
I~-----------------t------------V--------------------~-~r-t
( 10 23/32 -------/
/
I
\
---------
---
_ _ _ - - - - - - - - - - - j'- - - --
~ 23 13/16-
a
,,__a_-
I
""
------
--------
-------
15 3/16
62 13/16
54 3/16
@MR
- NO:NfEJIIJIa '
~NC 2011 AIRPOA1
LAKELAND, Fl
PHONE: (663)1
Floc1d1 6\isj,;esa No, EB,
.
95 13/16
5 HE:REBY Cep.TH:'f: That
eonstruction plans sllown
hereon a.re in compHanea
Seetlon , 606 of tlla '997
Edition ollhs Standard
euUding Code and 110 MPI
DSGNR:
SCALE:
PLASTI-LINE, INC.
P.O. BOX 59043
KNOXV~LLE. TN 37950-9043
T.R.M. DWG.BY: T.R.M. CH'K BY:
NTS DATE: 10 19 99 DATE:
REV DATE INIT ECN
PROPERTY OF PLASTI-L1NE,INC
NOT TO BE DUPLICATED.
DESCRIPTION OF CHANGE
UNSPECIFIED RADII
=.015 R
TOLERANCES:
ALL DllolENSICNS ARE IN INCHES UNLESS OTHERWISE SPECifiED
.XX=:i:.03 .XXX=:i:.OI5 ANGLES=::l'
DESCRiPTION:
WALL HOLE PLACEMENT GUI
CUSTOlolER: PIZZA-HUT W-80 WALL 51
SHT 2 'OF 3 DRAWING NU\.lBER: B 2289 1
------ - --- ------------------------------------------------------------------------------------------------------------------------
------ - --- ------------------------------------------------------------------------------------------------------------------------
LIFTING
EYEBOLT _________
o
WALL
CW/HO LAMP
MOUNTING HARDWARE
1/2" BOLTS THROUGH WALL
1 /2" LAG BOLTS W/LEAD
SHIELDS
1/2" LAG BOLTS
1 /2" TOGGLE BOLTS ~E~CNLY
(8) 1/t' DIA. FASTENERS REQ'D,
MASONRY WOOD
M
>< >< ::
><
><
.........
,/
1/2" HARDWARE
BY INSTALLER
BALLAST
2 X 2 X 3/16
STL ANGLE
@MR
- NGlKfERiNQ
~Na 201' AIRPORT AOAO
LAKElA'lO. FL 33911
f'HO\f: I>6Jl68Z.1B2G
!"orids BUSj,;~so No, E$-i.NC1874
I HERESY ~E8T~: That thl
COnstrue~J()n plans shown
here"n ara in con,plian.;e 'Nit!l
See:ion 160a of the' 991
Elfllo" 0/ the Standard
'27~-
W. fl COVER. ;>,!,; 11734
OAT!: 3P.v DO
INSTALLATION INSTRUCTIONS
1. CONTRACTOR SHALL VERIFY ALL SITE CONDITIONS AND DIMENSIONS.
2. THE CUSTOMER'S BUILDING ENGINEER IS TO DETERMINE IF BUILDING
STRUCTURE WILL SUPPORT THE SIGN. THE CUSTOMER SHALL SUPPLY ANY
ADDITIONAL STRUCTURE THAT IS REQUIRED ON OR BEHIND THE WALL.
3. UNCRATE AND TEST LIGHT SIGN UPON DELIVERY AND NOTIFY PLASTI-L1NE
OF ANY PROBLEMS.
4. DRILL MOUNTING AND ELECTRICAL HOLES IN WALL.
MOUNT BRACKETS ON WALL.
5. MOUNT SIGN ON WALL BRACKETS (SEE MTG. HARDWARE TABLE).
6. RUN ELECTRICAL TO SIGN AND TEST LIGHT. .
7. REMOVE LIFTING ANGLE/EYEBOLT AND CAULK HOLES.
'8. CLEAN FACE AND SECURE.
9. CLEAN JOB SITE OF ANY DEBRIS.
10. INSTALLATION SHALL CONFORM TO THE NATIONAL ELECTRIC CODE AND OTH
APPLICABLE LOCAL CODES. THE SIGN STRUCTURE SHALL BE GROUNDED I~
THE MANNER SPECIFIED BY THE N.E.C.
DSGNR:
SCALE:
PLASTI-LINE, INC.
P.O. BOX 59043
KNOXV~LLE, TN 37950-9043
T.R.M. DWG.BY: T.R.M. CH'K BY:
NTS DATE: 10 19 99 DATE:
DESCRIPTION:
WALL HOLE PLACEMENT GU
CUSTCMER: PIZZA-HUT W-80 WALL S
SHT 3 . OF 3 DRAWING ~UMSER; B 2289 .
------ - --- ------------------------------------------------------------------------------------------------------------------------
------------------------------------------------------------------------------------------------------------------------
- ------ - --- ------------------------------------------------------------------------------------------------------------------------
------------------------------------------------------------------------------------------------------------------------
REV DATE INIT ECN
PROPERTY OF PLASTI-L1NE,INC
NOT TO BE DUPLICATED.
DESCRIPTION OF CHANGE
UNSPECIFIED RADII
=.015 R
TOLERANCES:
ALL DI\.jENSIO~') ARE IN INCHES UNLESS OTHERWISE S?ECif'IED
.XX=:t:.03 .XXX=:t:.015 ANGLES=:t:l"