Loading...
HomeMy WebLinkAbout00-9573 BUILDING PERMIT .- - CITY OF ZEPHYRHILLS (813) 788-6611 c#.5' Permit 09573 110 0 BUILDING .- 6l.!:; ELECTRICAL - Date 0-;2~ -0 Z) PLUMBING ~.. Sewer Conn "-. Water Conn: Property Owner: Job Address: Parcell.D, # Water Meter: Zoning: Description of Work FINAL -~dJ DATE Complete Plans, Specifications and Fee Must Accompany Application, C.O. - All work shall be performed in accordance with City Codes and Ordinances. DATE Inspector Valuation or . Contract Price c::< ~ ?? nt) City License Registration # ;Q<~59 State Certified License# ~ Company BUILDING ELECTRICAL ~ss , C--r.;.Phon~ PIJ,- 7 f;z ~o:; !> 7 o . t. 'i:.I"Jv~ ~ PLUMBING --:T: 7:8. "?OOL5 ~ltJl(l,{)S SLB ~ -24 ~Ot> $ !2- Tub Set Water Sewer Final au I ,>/04"';' . .~ (r / c>...1 )1( ~ /.., 100 Ftr. .>0. Pre SLB Lintel FRM. Insul. CL WL Sf Tp. Servo Rough In Meter Can Const. Pole Pool Pre-Meter Final ~ ~~2{,-oO ~ F-' lee I-.- .. ,j e eft. is,.He/ Breakers Ducts Insl. Compressor Final Driveway ~ b-U,-~o J;Z .sJ.~ ( g/L/C() Sf REINSPECTION FEES: When extra inspection trips are necessary due to anyone of the following reasons, a charge of Fifteen and 00/100 Dollars ($ 25.001 shall be made for each trip for each trade: 3/2/DO Sf( a. Wrong Address b. Condemned work resulting from faulty construction. C. Repairs or corrections not made when inspection called. d. Work not ready for inspection when called. e. Permit not posted on job site. f. Plans not at job site. g. Work not accessible. The payment of inspection fees shall be made before any further permits will be issued to the person owning same. ..' 1 "~.. t ..J ~ r ~ ~ ,~ ..f.: .L .:;:.- 1IIi f ~ ~ . ~ ..0 - ); ~ (.;) l ~ ~-- ~ C. ~ , jti J3!!!- W tr ~ ~ '" <(:. ..., ~ ~ vP{~ J (~I ~- '7 ~6 {,l~ A'd 171 ~ Y> >1 j\ i'\, ~~ ~ tf "-lI ti ' ao -./ ~ ~ f ;I H ~ 68 t66l 'JNI '1'9' .LHOlHJ.dOJ @ 'JNI '9NI1I3l'119N3 NY7c/ US.LSYJV SSUfl.L:JflU.LS JVflNIIVfl7Y 'Q31'o'JlaNI S'o' 31'o'ld l)SSn~ .:10 31na3HJS ~3N31S'o'.:I 3sn ')i0 SI (]) 1rlll):J NI NI'IDHS S'o' IH!Jli!ldn a3NOIlISDd 2XI aNII 2X2 dOl 3Hl Hlll"I @ 1rll130 !JNIsn '31dl-/IIX3 '511'0'130 SNOIlJJNNOJ 11'>' NI O]l'>'lO~ Ja N';IJ ad 2X2 ON'>' aD 2XI 'SJION ( NI1~nd O.lNI 031E>NV SWS .to' xO~tl (z) - NOI.103NNOO 3.lVN~3.l1V) JlnQ3HJS llJd NHn10J Q) lII;j13Q ~31N3J NO ..2 SHS <!II I OIl lSDd HJION J 30lS HJV3 SI'lS 0111 . l]NN\fHJ 'J]!l .91/ I -- NIl!lnd 'J]!l 01 OJHJION NIl!lnd @ lII;j 13Q r!'OS dV1!l3AO ~rv Ox w 8 N . ,... ~~:q V)c:~ " <: M . '" c; I o " ~ '1\01]11 : ]lna]HJS I:t]N]lS\f.:l 3]S S!l.JH 10 11v o : lSOd@ Q) !lO.:l 30lS I HJV3 SHS 01. . Jsn n Sr'lS .Z JOIS HJVJ SI'lS 01' t1 81'lS S ' l @ JOIS >0\13 SI'lS 01' II 81'lS e ' l G) JOIS >oy] SI'lS 01' II el'ls l ' l 00 ]01S HJ\lJ SI'lS 01' 01 el'ls 9 ' l (D@ ]01S >01'] SI'lS 0 I' 8 el'ls t , l Q) JOIS HJVJ SI'lS 01# 9 8d t , l G> 301S >OY3 SI'lS 01' . ad (" , Z @@ 03~WlO3!l S!l3N31SYJ 321S 1 SOd 3lnQJHJS ~JNJ1S\jj @ llld lJQ HV]!I 01 lvno] SS]N~JIHl NIH ]lV1d 13SSn9 o o ~f\I Ox w Brv . r ~ ~ ::i VI z ~ <: '" " ~ . '" C> 2 SJHIl ]lna]HJS I:tJN31SVj ]sn o o SrlS .Z SHS 2/1 lor. 2 /1"1 aJI'I]!lJS 1IlN/l]lNI '!l0 2 X I SHS 2/1 1 DIM 2 /1'1 aJI'I]dJS 1VN!lJINl 'au 2 x I . 0 ... x OZ "'0 -n ::;: , :r ~ I'\J~ \ VI o~ (~ !Xl 00 _I'\J ,., Z L -. . 0 ~l'l ",0 "'VI "", "'VI I~ lIl;jlJQ HV]!I dV1!l]^0 I o~ : ~ 1\01]!I : J1na]HJS /:l]N]lSV.:! JJS S!l]HIO 11v o : lSOd@ Q)I:tO.:l Jals I HJV] SHS aIM . Jsn I -... SNOl1J3NNOJ Nl^JnlOJ 01 SNOl1J3NNOJ NVJnlOJ 01 !lHS .2 \' //~ g (q \ Nrlt:Jnd l^JV38 1 , Jill , .. . . . . =: . . If; ,.661 ':)NI ''IV .LH::>IH}.dO:) @ ':>NI '9NIH3::t119N3 NY7cl H:!.LSY/f S:!Hn.L:JnH.LS /fnNI/fn7Y NCIJ.::l3NNC:) t6' lIV~ ~I\IH:J ~ a1CIUl.NI @ NCIl:l3NNlJJ 21 lI\I~ ~I\IH:J l!IJI~lNI lJJ) NCIl:l3NNC:l ll"'~ 1l1'VH:l lIOI1l31X3 ~ SNS oil to I'" J, 'III" "lJNNYHO &N~ .'Vl SPIS 011 .. 1M "lJNNYft:l .n. lIOIlI3l.NI I INOIl.:IZ _ III -""'S III I as oil I llNlG1SYJ llOAlWI CD lI'vI13a r SNOI1J3NNOJ lIld~ ~I\7HJ I >10 NOI.LV10dl:l3.LNI X X tt'H L9'~l 00',:l O~'S L9"S H'S OO'S 00'9 .o-.S X X tt'Sl L9'9l tQ.U OO'Ol tt'OI L9'S OS'S tt'9 .o-,S X X L9'Sl tS'Ll L9'tl tQ'Ol OO'll H'Ol H'S tQ'9 .o-,L X X X tt'Sl O~'~l L9'll tS'll tS'Ol ts's tt'L .0-,9 X X X X O~'Sl tS',:l OO'tl OS'll tQ'Ol OO'S .o-,S X X X X L9'9l tt'~l O~'~l OS',;l L9'H L9'S .o-.~ X X X X OS'Sl OS'9l 00'9l , tQ.tl OO'tl ~L'6 .o-.t aws exc: aws sxc: aws LXC: aws 9xc: aws ~xc: as ~Xc: ad ~x~ as txc: ad txc: adC:XC: ~NIO\fdS (N) (wl (ll ()l) (rl (Il (Hl (~l (,f) (ol Hd... Ol:~ O.L dn savOlONIM .::ISd J. .::IOO~ N33~OS - .::ISd t~ S1TlfM N33~OS H3.::1 1""'1030 NI .LH~13H N...moo ...n"'I)("", I~ 318\f~ -I l1clllYX3 a~NSN\f1"i '" !M:MII :J1IYJ T -L .LHE>l3H ' ,2L 3lN t T lflI3I .GllI NWnlOJ . . . I: e It lit S . II . ... .- -~~~ .~. >..J........~~~..J,UUo.AJ...> iIJ.1J.1J.11~JJ.lr tU.I' ....,.., - ~1f38 dlfNS tlO 8~S 'dAl ( A<JIfONO::J3S ) - Nll<Jnd sns 'dAl S<J3N31SIfJ <JOJ 3ln03H::JS 33S 9 01 6 x (; S 01 8 x (; S 8 L x (; 10 L 9 x (; I: S S x Z I: S 10 x Z ~1f3S NIl<Jnd JO Y'/If38 A<JIf~I<Jd ~\f38 NIl<Jnd 30lS H::J1f3 SY'/S 0 LtI OlNI S~S OLtI ( A<J\fONO::J3S ) ( Y'/\f38 A<JIfY'/I!:ld ) Y'/1f38 dlfNS tlO 8Y'/S 'dAl ~'138 d'lNS <JO 8YiS 'dAl '8'd OSO' - I: x c: '. ~'138 d'lNS tlO 8~S 'dAl Yi'l38 d'lNS !:lO 8YiS 'dA! 'dU 'dA! I SlJ\f 130. NOLl03NNOO V\l\f38 01 V\lV38 / Nlll:lnd I NY7cf Y3.LS'y;/'~~~~oJ:J~.LS~=: ~ SM]CiJS G]CilnO]Ci ]Hl ]1 \lGOt'lOJJ\I 01 Hl:JN]7 ]1 \lICidOCidd\l N\I Hl/M lno 0377\1J S]l \l7d 13ssm JO O\l31SNI o]sn ]8 ..( \It'I Ci\l8 1 \l7J "<;Z IX" fr \I @ lI\;i13G ,,9 "oz S~S Zl~ 0" zr 81"lS 6Xl ,,9 "oz SV'lS 0 l 0" vv ,,9 "oz SV'lS Zl 0" zr 81"lS gXl ,,9 "oz SV'lS Ol 0" Ov ,,9 ,,9 ~ Sf'lS O~# Oil 9l 81"lS LXl ,,17 ,,9 ~ Sf'lS O~# Oil g 81"lS 9xl ,,17 ,,'V ~ Sf'lS O~# Oil 9 ~ 8f'1S vXl "q" uD II S30lS H108 3Z/S S~3N31S'i.:! 1'v'101 1"l'v'38 0 @ lI\;i13G s ..oz SV'lS Zl~ 0" zr 81"lS 6Xl ..9 ..oz SV'lS OLD" 01- ..~ ..oz SV'lS Zl~ 0" \lZ 81"lS gXl .9 ..OZ SV'lS Ot 0" 9r 0 0\ ,S; "Ol Sf'lS O~# Oil 9l 8f'1S LXl 0 0\ 0 0 ,S; ..9 ~ Sf'lS O~# Oil vl 81"lS 9xl .J ,S; "v L Sf'lS OL# Oil 9L 81"lS vXl ..q" ,,0 II S30lS H108 3ZIS S~3N31S'v'.:! l'v'WI 1"l'v'38 @ lI\;ilJG 31~ld 13ssn~ ~Ol~31X3 ......... -- ......... -- o 0 y o 0 000 o 0 000 o 0 000 000 c. (2) 11'v'130 o o o N33~JS ~V3lJ 01 ~3j~VHJ 8~ I t818 ,,9 ..oz S~S il~ 0" zr 81"lS 6Xl ..9 ..oz SV'lS OLD" 01- ..9 "oz SV'lS Zl~ 0" zr 81"lS gXl ,,9 "OZ SV'lS Ol 0" 01- ,,9 ,,9 ~ Sf'lS O~# Oil 9l 8f'1S LXl ,,17 ,,9L Sf'lS OL# Oil tl 81"lS 9xl "v ..vL Sf'lS OL# Oil 9L 81"lS vXl ..q" ,.0 " S30lS H108 3ZIS SmN3IS'v'.:! l'v'WI Vfv38 'v'N 'VN Sf'lS OL# Oil gl:' 81"lS 6xl 'v'N 'v'N Sf'lS OL# Oil vI:' 81"lS gXl 'iN 'iN Sf'lS OL# Oil 01:' 8f'1S LXl 'VN 'iN Sf'lS O~# 0<'1 u: 81"lS 9xl 'iN 'iN SI"lS O~# 0<'1 t ~ 8f'1S vXl ..q" ,.0 .. S30lS HW8 3ZIS S~3N3IS'V.:! l'v'WI f'I'v'38 Ci\l7/t'11S ](1V St'lV]8 Ci]Hl0 8t'1S 6xZ V S\I OJ7VJS JCJV NMOHS St'lVJ8 SS]N>lJIHl 77VM 01 wnw (10 (1]1 V](1:J ]8 lSnt'l SS]N>lJIHl 13SSn:J ,.z N\lHl SSJ7 ]8 10NN\lJ SM3CJJS N3JM138 DNIJVdS [ S,IV Ea NIOd.L03NNOO I'W38 O.L I'IIV38 ] . . " . "- "'""u_u '<1-...J> UIU' II""NAH r I II I I II . il !/ I I II MARK DESCRIPTION WT/FT AREA WALL t FLGE t ALLOY I STRUCTURAL ITEMS DESCRIBED (A) 1 x2 OPEN. BACK 0.276 0.230 0.044 0,044 6063- T5 /B 1 x3 OPEN BACK 0,384 0.320 0.050 0.050 . 6063- T5 C 3x2 PATIO BEAM 0,681 0.579 0.050 0.050 6063- T5 $ D 2x2 PATIO BEAM 0.518 0.441 0.044 0.044 6063- T5 1.1 E) 2x2 SNAP BEAM 0.542 0.461 0,041 0.041 6063- T5 F 2x3 PATIO BEAM 0,681 0,579 0.050 0.050 6063- T5 G 2x3 SNAP BEAM 0.680 0.578 0.045 0.045 6063- T5 Hl 2x4 PATIO BEAM 0.799 0.679 0.050 0.050 6063- T5 I J 2x4 SNAP BEAM 0.786 0.668 0.045 0.045 6063- T5 . J 2x4 5MB 1.008 0.857 0.044 0.135 6063- T6 . KI 2x6 5MB 1.342 1.141 0.054 0.135 6063- T6 , , (L 2x7 5MB 1,515 1.288 0.057 0.135' 6063- T6 j ..... M 2x8 5MB 2,147 1.826 0.072 0.224 6063- T6 . Nl 2x9 5MB 2.317 1.970 0.072 0.224 6063- T6 . 0 3x2 POST BEAM 0.800 0.680 0.070 0.070 6063- T5' P 3x3 SCALLOPED TUBE 0.596 0.507 .045-.078 .045-.078 6063- T6 QJ 3x3-0,093 TUBE 1.256 1.068 0,093 0.093 6063- T6 R) 3x3-0,125 TUBE 1,691 1.438 0.125 0.125 6063- T6 ',. S) 4x4-0.125 TUBE 2.279 1.938 0.125 0.125 6063- T6 , . -I I -"'. ANGLES DESCRIBED , (AA) 2x2x.125 ANGLE 0.569 0.484 0.125 0.125 6063- T6 '; AB 2x2x,093 ;,ANGLE 0.427 0.363 0.093 .' 0.093 6063- T6 lAC 1 x1 x, 062 ANGLE 0.141 0.120 0.062 0.062 6063.- T6 AD 1 x2x. 062 ANGLE 0.214 0.182 0.062 0.062 6063- T6 ,AE 1 x3x, 11 0 ANGLE 0.323 0.275 0.070 0.070 6063- T6 RECEWJNG CHANNELS DESCRIBED (CA) 1.5x2.125x,062 0.362 0.308 0.062 0.062 6063- T6 CB 1.5x3.125x.062 0.438 0.372 0.062 0.062 6063- T6 (CC) 1.75x3.23x.110 0.834 0.710 0.110 0.110 6063- T6 SUPER GUTTERS DESCRIBED (GA) 4"x4" EXTRUDED 1. 270 1.080 0.070 0.070 6063- T6 (GB 4 x5" EXTRUDED 1. 358 1.155 0.075 0.075 6063- T6 . - y ~ ALUMINUM STRUCTURES MASTER PLAN: \ 17 . . " :tJ- , ~HC. @ COPYRIG~T At, INC. 19~4'". '. ,. ;"..".'. .' '-.0d _......._._----._~_....,-.....,..,.,..,..,....----- .R>(- P".--'---".' -~,", . I I I J ! -UJ. . Ll. MAXIMUM ROOF BEAM SPANS IN DECIMAL FEET 'Uaf SCREEN ROOF I SCREEN WALLS EXAMPLE: . ... WIND 110 MPH DEFLECTION Ll60 POOL ENCLOSURE J, <-t COLUMN USED f-> , 8 'WAll 011 ROOF (F) (G) (H) (I) (J) (K) (l) (M) (N) BEAM SPACING 2x3 2x3 2x4 2x4 2x4 2x6 2x7 2x8 2x9 I 0:1 . USED ,PB SMS PB SMS 5MB 5MB 5MB 'SMB 5MB ~ . 4'-0" 18.42 19.08 19.25 19.25 19.25 19.25 19.25 19.25 19.25 ,(H) 5'-0" 17.08 17.58 17.75 17.75 17.75 17.75 17.75 17.75 17.75 2x4 6'-0" 16.08 16.58 16.75 16.58 16.75 16.75 16.75 16.75 16.75 ~., . . l. PB 7'-0" 15.25 15.58 15.75 15.75 15.75 15.75 15.75 15.75 15.75 8'-0" 14.58 14.92 15.08 15.08 15.08 15.08 15.08 15.08 15.08 r .. 9' -0'" 13.92 14.42 14.42 14.42 14.42 14.42 14.42 14.42 ' 14.42 .. 4'-0" 21.08 21.75 21.92 21.75, 23.42 23.42 23.42 23.42 -23.42 ~ (J) 5'-0" 20.08 20.08 20.25 20.08 21.58 21.58 21.58 21.58 21.58 i J 10,. 2x4 6'-0" 18.42 ' 18.75 18.92 18.92 20.25 20.25 20.25 20.25 20.25 , 5MB : 7'-0" 17.42 ,,17.92 17.92 17.92 19.08 19.08' 19.08 19.08 19.08 t. \ " '. :~~~~{; 8'-0" 16.75 . 17.08 17.08 17.08 18.25 18.25 18.25 18.25 ...18.25 ';"." 9'-0" 16.08 16.42 16.42 16.42 17.42 17.42 17.42 17.42 17.42 "" ~l " . C";: 4'-0" 28.08 28.58 28.75 28.58 29.92 31.92 31.92 31.92 31.92 , (K) 5'-0" 26.08 26.42 26.58 26.58 27.58 29.25 29.25 29.25 29.25 .t!.~ : 2X6 6'-0" 24.58 24.92 24.92 24.92 25.92 27.42 27.42 27.42 27.42 ~ ;;' 5MB 7'-0" 23.25 23.58 23.75 23.58 24.42 25.92 25.92 25.92' 25.92 .~~ t.' 8'-0" 22.25 22.58 22.58 22.58 23.42 24.5& 24.58 24.58 ,:- 24.58 IX, ", 9'-0" . 21.42 21.58 21.75 21.75 22.42 '23.58 23.58 23.58 23.58 . . "';1\ . ~Hl . '... "" ;/ ., . 4'-0" 31.58 ' 32.08 32.08 32.08 33.08 34.92 35.92 35.92 "35.92 . .',T" ,-. ,j ,.j' .' , . (l) 5'-0" 29.42 29.58 29.75 29.75 30.58 32,251 33.08 33.08 33.08 ;........' , 2x7 6~.-o" 27.58 27.92 27.92 27.92 28.75; 30.0Sl . 30.-g2 30.92 30.92 ./..,!'.,'" !t..' " 5MB 7'-0" 26.25 26.42 26.58. 26.58 27:'25 28.42 29.25 29.25 29.25 :'" 1 .. 8'~" 25.08. 25.25 25.42 25.42 26.08 27.08 27.75 27.75 27.75 9':0" 23.92 24.25 24.25 24.25 24.92 26.08 26.58 ,26.58 26.58 '., t:" '. ..' ,(t'f: . , f I 4''''" 38.25 38.58 38.58 38.58 39.42 40.92 41.75 44.25 44.25 (M) , is ':.0" 35.42 35.75 35.75 35.75 36.58 ".37.75 38;58 .40.75 40.75 2x8 6'-0" 33.42 33.58 33.75 33.58 34.25 35.42 36.08 37.92 37.92 \; ~ 5MB 7'-0" 31.75 31.92 31.92 31.92 32.58 33.58 34.08 35.92 35.92 ' ., r,..'. r 8'-0" 30.25 30.58 30~58 30.58 31.08 32.08 32.58 34.08 34.08 \ , 9'-0" 29.08 29.25 29.42 29.42 29.92 30.75 31.25 32.75 32.75 ~ '. ~ " :\ 4 '-0" 41.92 42.25 42.25 42.25 43.08 44.42 45.08 47.42 48.42 (N) 5'-0" 38.92 39.08 39.25 39.08 39.92 41.08 41.75 43.58 44.58 2x9 6'-0" 36.58 36.75 36.92 36.75 37.42 38.42 39.08 40.75 41.58 , . - .".. 5MB 7' -0" 34.92 34.92 34.92 34.92 35.58 36.42 . 36.92 38.58 39.25 8'-0" ..33.25 33.42 33.42 33.42 33.92 34.75 35.25 ,36.75 37.42 9'-0" 31.92 32.08 32.08 32.08 32.58 33.42 33.92 35.08 35.75 .' , f INTERPOLATION BETWEEN VALUES IS PERMISSIBLE . - \. ,. ,,I .'- \... ~ C' , .. ,. . " ~ ALUMINUM STRUCTURES MASTER PUN .. ; .ff. : 52 ..;; -, ;....;;,.,.. , ENGI~ING.INC. @ COPYJbqHT AL, INC. 1994 . . - -r - . , -c- '., . . ; !\:',.- .ti, ; :~,~4:'; _':" _~ - .. I" - . ),', '. I GUTTER TO FASC~A DETA~LS I j I 3 FASTEN GUTTER W 10. 2" o 1 t' O,C, - STAGGERED 2" lOx 3" SCREWS C EA, CLlP@ 2" . .075 ALUM ANGLE CLIP C EA. BEAM@) SMS ;,: : ,J GUrrER DE'.LS) j STRUCTURAL GUTTER EA, RAFTER SPACER FERRULE 4>> EA. B~ RIGID ALUM. OR PVC PIPE) 4 ;,: : ,J GUTTER DETAILS) < STRUCW",,- GUITERj f2\CONTINUOUS ANGLE, 1 . 2 0 B. OR WOOD WEDGE \6ITO PLUMB GUTTER WHEN REQUIRED REF, SIMILAR DETAIL ABOVE FOR 1YPICAL NOTES, REF, SIMILAR DETAIL ABOVE FOR 1YPICAL NOTES, / (REF. BEAM TO GUTTER DETAILS) STRUCTURAL GUTTER / / (REF, BEAM TO GUTTER DETAILS) " 5" STRUCTURAL GUTTER ~ MAY BE REVERSED USING SAME FASTENER PATTERNS 2, X - DENOTES ORDER OF INSTALLATION PROCEDURES 3. ENGINEERING. INC. DOES NOT WARRANTEE, EITHER ,EXPRESSLY OR IMPLIED, THE STRUCTURAL INTEGR11Y OF THE EXISTING STRUCTURE. SGF 50 ~ ALUMINUM STRUCTURES MASTER PLAN EtD&fI<<), NC. @ COPYRIGHT A4 INC, 1994 I BEAM TO OUrrER--DET A~LS I - -- - --- 2' x ,075 ALUlA, ANGlE ClIP (1) 0 EACH BEAlA LOCATION (2)-/10 SlAS SEE GUTTER TO fASCIA DETAILS (4)-/12 x 3/4' SlAS INTO GUTTER (1' lAIN, SEPARATION) 2' SlAB SEE SPAN CHARTS (4)-#12 x 3/4' SlAS EACH SlOE: 18 SlAS THRU CHANNEL INTO BEAll ~5' 2 t /8' x 1 t /2' REC, CHANNEL ,062 2' SlAB SEE SPAN CHARTS (4)-/10 SIIS INTO BEAlA ( EACH SlOE) (2)-/12 x 3/4' SlAS INTO' GUTTER (1" lAIN, SEPARATION) #8 SIIS THRU CHANNEL INTO BEAM ~. 2 I/S' x l' REC, CHANNEL .062 - 2' x ,075 ALUlA, ANGLE CLIP J (t) 0 EACH BEAll LOCATION /' 2' SlAB SEE SPAN CHARTS - -- ---, SEE GU TTER TO f AsaA OETAlLS 2 x 2 INlERNALL Y f ASlENEO TO BEAM 'MTH (2)-/l0 x 1 1/2' SIIS (4)-/12 3/4 SIIS EACH SlOE (4)-#12 x 3/4 SlAS INTO GUTTER (t' "IN, SEPARATION) 2 1/8' x t 1/2' REC, CHANNEL ,062 445' - -- - - ---, SEE GUTTER TO f AsaA DETAILS 2' x ,075 ALUlA, ANGLE CLIP (1) 0 EACH BEAll LOCA nON /' 2' SlAB SEE SPAN CHARTS DOOR JAlAB INlERNALL Y f ASlENED TO BEAll 'MTH (2)-/l0 x 1 1/2' SIIS (4)-#12 x 3/4 SlAS EACH SlOE (4)-#12 x 3/4 SIIS INTO GUTTER (1" IIIN, SEPARATION) 2 l/S' xlI /2' REC. CHANNEL .062 445' NOlE: AL ENGINEERING, INC, DOES NOT WARRANTEE, EITHER EXPRESSLY OR IlAPLlEO, THE STRUCTURAL INlEGRITY Of THE EXISTING STRUCTURE, ~ ALUMINUM STRUCT. URES MAS. TER PLAN ENCHEB<<l ~. @ COPYRlqHT_~ INe: 1994-1, I i ,I ~ I II I: 49, il! l CAGE BRACING r r ..J ..J < )0 Q ~ ~ ~ ....AU MocING su: IlE."T4lLS IIELDIi ~ 1 TCP STRAPS i!><2 NG.L V8 '0//4 till SIlS \ DETAILS ] ROCF L VALL lllAClNG R(QUIRE:D F'!R CiIIJLJ:.HlP,F1.AT sa: NDTa IEI..Dv ~ ~/{~J///~ " , " , " .,. La i " " J " " " " i .,. " , " .,. " .,. " " " .,. " ~....AU -..c..a sa: IlE."TAlU IIUN ~ ..J ..J < )0 '" '" ~ ~ " " " DETAIL "f' " " " "D' " S! .,. ~ , I " ~ " " )0 " / " " .,. .,. " ,- · 2' 0,8. EXT. TYPICAL TOP STRAP BRACING T'I'P WAIl. BRACNG CQRr:::CLU~ I ST~lM.ns STEEL Cot.BLE HlN THIC1O€SS 3/32' 318" EYE IIllL T <TYF? .... / DClJBLE \JASliE~ & NUT EAOf SIllE \EA~ PUlUN ex!NCU; \J / Y .uJ SIlS I III I' .10 SMs I I I NOTES: CORNER CABLES OR RIGID BRACING SHAll BE USED ON ANY WAll NOT DIRECTlY FASTENED TO THE HOUSE IN ORDER TO RESIST DIAGONAL STRESSES DUE TO WINDlOAD, THESE CABLES SHAll EXTEND DIAGONAllY FROM EACH CORNER, TENSION SHOULD BE ADJUSTED BY THE USE OF TURNBUCKlES. TURNBUCKlES SHAll HAVE lOCKlNG DEVICE TO PREVENT lOOSENING, THIS STAINLESS STEEL CABLE SHAll BE AT lEAST 1750 POUNDS TEST STRENGTH. THE BOTTOM OF THE CABLE SHAll BE FASTENED TO THE SLAB WITH THREE 1/4" FASTENINGS OR TWO 5/16" FASTENINGS WITH A 118" STRAP. EITHER WAll BRACING OR TOP STRAPS SHAll BE REQUIRED, ~ ALUMINUM tTRUCTURES MASTER PLAN .a ENGlhEERING. 1He. @ COPYRIGHT AL, INC. 1994 I I I I, I 45 APPLICATION FOR PERMIT CITY OF ZEPHYRHILLS BUILDING DEPARTYENT /. - -7 5-iP DATE RECEIVED U7 A PLANS REVIEW FEE JOB ADDRESS .-l04'1 (,qqJ.. ~ B " ""-c/t\ OAK. ~~5T JO FD~ WA7 PHONE-C3SZ.) 5;l/ - 398/ OWNER'S NAME LEGAL DESCRIPTION: LOT(S) SUBDIVISION OAK Ut-esr M t'i(,O/otl. BLOCK PARCEL ID # 02 -16-} /1"" O~ ~o -00000 - '--oJ AJ (OBTAIN FROM PROPERTY TAX NOTICE) WORK PROPSED: DNEW CONSTRUCTION o ADDITION DALTERATION o REPAIR o INSTALL o SIGN o MOVE o DEMOLI SH PROPOSED USE: DSGL FAMILY DWELLING o COMMERCIAL DMULTI-FAMILY o INDUSTRIAL 0# OF UNITS o SWIMMING POOL o MOBILE HOME o OTHER c:J RESTAURANT & HEALTH DEPARTMENT APPROVAL DESCRIPTION OF WORK L-I~" 0/'0...._./ r.. .- ........ \",,'T" ~ __ \ "- .......,.. ~ } I pc> i ~ I volt. l- S \:...0'<'"", fl()U-_ BUILDING SIZE SQUARE FOOTAGE HEIGHT RESIDENTIAL: COMMERCIAL: ATTACH (2) PLOT PLANS & (2) SETS OF BUILDING PLANS & (1) SET ENERGY FORMS. ATTACH (3) SETS OF BUILDING PLANS & (1) SET ENERGY FORMS. PROPERTY SURVEY REQUIRED FOR ALL NEW CONSTRUCTION. o BUILDING $ PERMITS REQUESTED L Lf( , 00 , ,,' VALUATION OF TOTAL CONSTRUCTION o ELECTRICAL AMP SERVICE ~ FLORIDA POWER o W.R.E.C. o PLUMBING o MECHANICAL $ VALUATION OF MECHANCIAL INSTALLATION o GAS o ROOFING o SPECIALTY o OTHER TYPE OF CONSTRUCTION: 0 BLOCK o FRAME o STEEL o OTHER FINISHED FLOOR ELEVATIONS IS PROJECT IN FLOOD ZONE AREAD YES o NO SIGNATURE { t!if!l COMPANY JTI3 Pol ( . t. _ ' STATE CERT OR REGIST n CIT~PR r:JING ).. > 'd ' . .r ~ ..- ************************************* ** * * **~**~*~* -, BUILDER ELECTRICIAN COMPANY HAwKINS E le,-w-..ettl --'" . ~ STATE CERT OR REGIST # eCc:X::)o~Q.,\ SIGNATURE~. CITY PR~~~~NJ) I =t'd. . ,.._-_ ***********************************~~,\~*~ry:*~~ PLUMBER COMPANY STATE CERT OR REGIST # CITY PROCESSING # SIGNATURE * * * * ** * * * **,* * * * * * * * * * * ** * ** ** * * * * * * ** * * * ** * * * * ** ** *** * * * * ** ***** ** MECHANICAL COMPANY STATE CERT OR REGIST # CITY PROCESSING # SIGNATURE ********************************************************~k******** OTHER COMPANY STATE CERT OR REGIST # CITY PROCESSING # SIGNATURE ***************************************************************** CONDITIONS Of' PEHMTT AFFIDAVIT A. NOTICE OF DEED RESTRICTIONS The undersigned understands that this permit may be subject to "deed restrictions" which may be more restrictive than City regulations. The undersigned assumes responsibility far compliance with any applicable deed restrictions. B. UNLICENSED CONTRACTORS AND CONTRACTOR RESPONSI3ILITIES If the owner has hired a contractor or contractors to undertake work, they may be required to be licensed in accordance with state and local regulations. If the contractor is not licensed as required by law, both the owner and contractor may be cited for a misdemeanor violation under state law. If the owner or intended contractor are uncertain as to what licensing requirements may apply for the intended work, they are advised to contact the City of Zephyrhills Building Department, 813-788-6611. Furthermore, if the owner has hired a contractor or contractors, he is advised to have the contractor(s) sign portiorrs of the "Contractor Sections" of this application for which they will be responsible. If you, as the owner signs as the contractor, you are indicating that you, rather than the contractor, are responsible for the work. If the contractor wishes you to sign as contractor that may be an indication that he is not properly licensed and is not entitled to permitting privileges in the City of Zephyrhills. C. TRANSPORTATION IMPACT FEES AND UTILITY CONNECTION FEES D. CONSTRUCTUION LIEN LAW (CHAPTER 713, FLORIDA STATUTES, AS AMENDED) I certify that I, the applicant, have been provided with a copy of "Florida's Construction lien Law - Homeowner's Protection Guide" prepared by the Florida Department of Agriculture and Consumer Affairs. If the applicant is someone other that the "owner", I cerify that I have obtained a copy of the above described document and promise in good faith to deliver it to the "owner" prior to commencement. E. CONTRACTOR' S/OWNER' S AFFIDAVIT I certify that all the information in this application is accurate and that all work will be done in compliance with all applicable laws regulating construction, zoning, and land development. Application is hereby made to obtain a permit to do work and installation as indicated. I certify that no work or installation has commenced prior to issuance of a permit and that all work will be performed to meet standards of all laws regulating construction, City codes, zoning regulations, and land development regulations in the jurisdiction. I also certify that I understand that the regulations of other governmental agencies may apply to the intended work, and that it is my responsibility to identify what actions I must take to be in compliance. Such agencies include but are not limited to: *Department of Environmental Regulation-Cypress Bayheads, Wetland Areas and Environmentally Sensitive Lands, Water/Wastewater Treatment *Southwest Florida Water Management District-Wells, Cypress Bayheads, Wetland Areas, Altering Watercourses *Army Corps of Engineers-Seawalls, Docks, Navigable Waterways *Department of Health & Rehabilitative Services, Environmental Health Unit-Wells, Wastewater Treatment, Septic Tanks *U.S. Environmental Protection Agency-Asbestos abatement I also certify that, if fill material is to be used in Flood Zone "A" or "A,etc.", it is understood that a drainage plan addressing a "compensating volume" will be submitted which is prepared by a professional engineer registered in the State of Florida prior to permit issuance. A permit issued shall be construed to be a license to proceed with the work and not as authority to violate, cancel, alter, or set aside any provisions of the technical codes, nor shall issuance of a permit prevent the Building Official from thereafter requiring a correction of errors in plans, construction, or violations of any code. Every permit issued shall become invalid unless the work authorized by such permit is commenced within six months of issuance, or if work authorized by the permit is suspended or abandoned for a period of six months after the time the work is commenced. One 90 day extension of time may be allowed for the permit with fee charge of $15.00. The extension shall be requested in writing to the Buildi~g Official. An approved inspection must be logged during each six month period, or the project will be considered abandoned. WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE EOR IM~ROVEMENTS TQ YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUIJ.,l,.iil'io~'-.iH~:~.~~k~'\ "BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. JOBS UNDER $2'SO"dZ:-M NEED TO RECORO AND POST A "NOTICE~M SIGNATURE: OWNER OR AGENT SIGNATURE: CONTRACTOR STATE OF FLOR~.L STATE OF FLORIDA ~ . . '\ COUNTY OF ~5Lc!.U COUNTY OF _r..tJ.:~C!.. u The foregoing instrument was acknovlledged The foregoing instr':,ment was ~knowledged . Before me this J~?day Of~E , H'2o.J Before me this .L'22.:~ Of6Ul-'C , ~..2Q~,) by aM~'(F..s _' :6/J'?/T/ by (ljl/-ll{ir~ }, _;n/T~ ,~. (name of person acknowledged) V_. _Jname of person acknowledged) ~ho is personally known to me, or ~o is personally known to me, or Dwho has produced '~(t..y pe~ of identif...icatiOn) a~9r~did id t take an o.ath ('---~~ ... ~~ c:-~i~~e of persOn~king a~kno.wledgment ~lilC ~)FI~/lJ..-'p Name ~Fl.: prinioi,~iecgwe~lrcfmped ,~:"A'~ MY COMMISSION # CC893160 EXPIRES ~'.JIl4-,:,;<~ February 22, 2004 -. .". ....f'. ilONO€D THRU TROY FAIN INSURANCE,INC of identification) ake an oath. C ~ a vJr\.v ! JO~" ~ 6.-J.. r;:: fflA.K Cvesr- ~ tf(;-2 U~I ~v A-c.. TIll' JTr5 ~cJ/~. ($10) 7fl-03) 7 PA-v t 5~-J( \ 10' UTILITY EASEMENT S 84055'26" E I \ I I \ I I I I - _.J \ \ ----------------------------- .". ... --------------- 1 1 --------------,--, I 110.48 : : 1 I 1 ! , il 1 I I I :, , .~ r. ..110, '0, I . , 10 L() -r- 1 1 , 1 1 , 1 1 , I I !~ ,CJ PI,OT, PI,~~ SCAlE:: I' = 30 10' BUFFER EASEMENT fL& ~ ff~O ./-. I 1 I I ! I I /2 ~, NAI (j)- AND 12- 16 t./H ~611J. APPLICATION FOR PERMIT CITY OF ZEPHYRHILLS BUILDING DEPARTMENT ~/ J. 7-J B.- I'":)~.J. OWNER IS NAKE Jb~11 ;;~ ~712-- oA4- PHONE OWNER'S ADDRESS GeT 4/?1y JOB ADDRESS I~ LEGAL DESCRIPTION: LOT(S) BLOCK PARCEL LD.' D1-1(, - 21 . l>l') cJ ~ QQnoo' Lo>r 2u ~~~ WORK PROPOSED:_New Construction .1-Addition _Alteration SUBDIVISION O~ /A '+ ~~~ (OBTAIN FROM PROPERTY TAX NOTICE) _Repair _Install _Sign _Move _DeJlolish PROPOSED USE: _Single Faaily _M/F _, of Units _M/H _Swim. Pool ..:;LOther ~ ~ _eo..ercial , _Indust. DESCRIPTION OF WORK: _Restaurant & Health Departllent Approval ?~L f~ ~.r BUILDING SIZE: 7--7 X Jr. I 7 Square Feet. /' I I d" -I.J.Height RESIDENTIAL: COMMERCIAL ATTACH (2) PLOT PLANS & (2) SETS OF BUILDING PLANS & (1) SET ENERGY FORMS. ATTACH (3) SETS OF BUILDING PLANS & (1) SET ENERGY FORMS. PROPERTY SURVEY REQUIRED FOR ALL NEW CONSTRUCTION. PERMITS REOUESTED _BUILDING $ '-?-Co - Valuation of Total Construction _ELECTRICAL AMP Service Florida Power Corp. W.R.E.C. _MECHANICAL $ Valuation of Mechanical Installation _PLUMBING GAS ROOFING SPECIALTY TYPE OF CONSTRUCTION: _Block _Fraae _Steel Other FINISHED FLOOR ELEVATIONS: FT. IS PROJECT IN FLOOD ZONE AREA? YES NO ****************************************** CONTRACTOR SECTION BUILDER COMPANY State Cert. or Regist. . City License Registration f ****************************************** Signature ELECTRICIAN COMPANY State Cert. or Regist. , City License Registration . ****************************************** SilmSlture PLUMBER COMPANY State Cert. or Regist. . City License Registration , ****************************************** Signature MECHANICAL COMPANY State Cert. or Regist. I Signature City License Registration , ~****** ****************************** OTHRR COMPANY ~~ h-hU/1? State Cert. or Re ist: I ~y C>o::;~ ."..~/ Signatu City License Registration # ~ /t<' ~ y ****************************************** APPLICATION APPROVED BY PERMIT OFFICER. CONDITIONS OF PERMIT AFFIDAVIT A. NOTICE OF DEED RESTRICTIONS Tbe undersigned understands tbat this perait lay be subject to "deed restrictions" wbich lay be lOre restrictive tban City regulations. Tbe undersigned assUles responsibility for cOlpliance with any applicable deed restrictions. B. UNLICENSED CONTRACTORS AND CONTRACTOR RESPONSIBILITIES If the owner bas bired a contractor or contractors to undertake work, tbey lay be required to be licensed in accordance with state and local regulations. If tbe contractor is not licensed as required by law, both the owner and contractor lay be cited for a lisdeteanor violation under state law. If the owner or intended contractor are uncertain as to wbat licensing requireJents lay apply for tbe intended work, they are advised to contact tbe City of Zepbyrbills Building DepartJent, (813) 788-6611. ' FurtherlOre, if the owner bas bired a contractor or contractors, be is advised to bave the contractor(s) sign portions of the .Contractor Sections" of this application for wbich they will be responsible. If you, as the owner sign as the contractor, you are indicating that you, ratber than the contractor, are responsible for the work. If the contractor wisbes you to sign as contractor that lay be an indication that be is not properly licensed and is not entitled to pmitting privileges in the City of Zepbyrbills. C. TRANSPORTATION IMPACT FEES AND UTILITY CONNECTION FEES D. CONSTRUCTION LIEN LAW (CHAPTER 713, FLORIDA STATUTES, AS AMENDED) I certify that I, the applicant, have been provided with a copy of -Florida's Construction Lien Law - HOJeowner's Protection Guide" prepared by the Florida DepartJent of Agriculture,and ConsDler Affairs. If the applicant is SOIeone otber tban the -owner", I certify that I have obtained a copy of the above described docUJeDt and prOlise in good faith to deliver it to the "owner" prior to CODenCeJent. E. CONTRACTOR'SjOWNER'S AFFIDAVIT I certify that all the inforaation in this application is accurate and that all work will be done in cOlpliance with all applicable laws regulating construction, zoning, and land developaent. Application is bereby lade to obtain a perait to do work and installation as indicated. I certify that no work or installation has cOllenced prior to issuance of a perait and that all work will be perforaed to leet standards of all laws regulating construction, City codes, zoning regulations, and land developaent regulations in the jurisdiction. I also certify that I understand that the regulations of other governtental agencies JaY apply to the intended wort, and that it is IY responsibility to identify what actions I lust take to be in cOlpliance. Such agencies include but are not lilited to: t DepartJent of EnviroDleDtal Regulation - Cypress Baybeads, Vetland Areas and EnviroDlentally Sensitive Lands, Vater/Wastewater TreatJent t Soutbwest Florida Water Managetent District - Wells, Cypress Baybeads, Wetland Areas, Altering Watercourses t ArlY Corps of Engineers - Seawalls, Docks, lavigable Waterways t DepartJent of Health & Rebabilitative Services, EnvirODJeDtal Health Unit - Wells, Vastewater !reattent, Septic ranks t US EnvirODJeDtal Protection Agency - Asbestos abateJent I also certify that, if fill laterial is to be used in Flood Zone "A" or "A, etc. ", it is understood that a drainage plan addressing a uCOlpensating volUle" will be subtitted wbicb is prepared by a professional engineer registered in the State of Florida prior to perlit issuance. A perait issued shall be construed to be a license to proceed with the work and not as authority to violate, cancel alter, or set aside any provisions of tbe technical codes, nor shall issuance of a perait prevent the Building Official frot thereafter requiring a correction of errors in plans, construction, or violations of any code. Every perait issued shall beC<lle invalid unless the work authorized by such perlit is cOlleDced within six tonths of issuance, or if work authorized by the perait is suspended or abandoned for a period of six IOntbs after the tile the work is cOllenced. One 90 day extension of tile, JaY be allowed for tbe perlit with fee charge of $15.00. The extension shall be requested in writing to the Building Official. An approved inspection lUst be logged during eacb six IOnth period, or the project will be considered abandoned. WARHIIG TO OIlIER: YOUR FAILURE TO RECORD A NO'I'ICE OF COMMElfCEMlN! MAY RESULT II YOUR PAYIIG 'NICE FOR IMPIIOVIMEIn'S TO YOUR PROPERTY. IF YOU IN!EHD TO OBTAII FIIAlfCING, COlfSULT WITH YOUR LINDER OR Alf AnORlEY BEFORE RECORDING YOUR MoriCE OF CONICIMm~:_:12'500 IN VALUE 00 NUl HIED 10 uI:or ctmICOOII" c;;;J:- ~ OR lIGm SIGIIIllIIIl: COIIJIlICIOR STATE OF FLORIDA COUN'll OF The foregoing instrument was acknowledged before me this , 19____ by STATE OF FLORIDA COUlfTY OF The foregoing instrument was acknowledged before me this , 19_____ by who is personally known to me or who has produced as identification and who did/did not take an oath. who is personally known to me or who has produced as identification and who did/did not take an o~th. (Signature) (Name Typed, Printed or Stamped) NOTARY PUBLIC (Signature) (Name Typed, Printed or Stamped) NOTARY PUBLIC JTP POOLS 6952 OAKCREST WAY SQ. FEET PRICE MAIN OR LIVING AREA $ 40.00 OTHER AREA UNDER ROOF $ 15,00 OTHER VALUATION $ - FEE SHEET ADDRESS $ - DRIVEWAY $ - BUILDING: $ 160.00 CREDIT: $ - BU'LDlNG LESS CREDIT: $ 160.00 ELECTRICAL: $ 25.00 PLUMBING: $ 25.00 MECHANICAL: $ - RADON: $ - TOTAL $ 210.00 SEWER: $ - WATER: $ - IRRIGATION: $ - TOTAL: $ - 111111111111 1111I1111I1111I1111I111I1111111111111111 11111111 2000078681 Florida Statute 7131s the Construction Lien Law. The owner needs to be familiar with aU Its passages. At a mlnlmum~ file a Notice 01 Commencement, protect your rights by obtaining a partial or complete "Release of Lien" prior to any payments and obtain releases from all providers belore making the final payment. . NOTICE OF COMMENCEMENT O)..-;H-'i-O:Hv _.oOOJO, o~oo Permit No. Tax Folio No. The undersigned hereby gives notice that Improvement will be made to certain real property, and In accordance with Chapter 713, Florida Statutes, the loll owing Inlormatlon Is provided In this Notice 01 Cqmmencemenl. (1) L~gal Description: (2) General Description 01 Improvement: I~GROUND SWIMMING POOL VIII Sc.." e taI\ l'?oOtN\ (3) Owner.lnlormaUon ,J'CH-\N ~ i3.{e",o,,\ I="ORO (a) Name and address: b' ,"2... O,i(Ues. w,,-y Ztflt"/" Hi ,Fl. ~ ~~40 (b) Interest In Property: OvJNe.,.-S ..- (c) Name and address 01 fee simple titleholder: .- I (4) Contractor (Name and Address): J'T'~ POG t ~II\,-l- { " (. \' j", G- . b I'll No"t~ LttKt, j)tc. (5) ~~r~~mo and Addross: '2 e.p '..y r 4 i IIJ f F /. J J I'Y / (b) Amount 01 bond: $ _ _ _....J .. .....-'____\. ~I So:::a cncnn ,..'0 N ~ W Soo 's~ SSN S N CllI N (D :::a Mill -In CSH>> c. . '1J SIS) ~ IS) IS) o - .. ., X' ~I o 1S)c... ::a cnm ,0 ta N"'1J ~ ~.... IS)-I .a::. IS)~ W;;ii (0.. ~g'"'1J --8':0 3~ o "'1J "'0 C') 0 c: Z ....0-1 ~-< ....0 W...r- COm ~ ...... ......... Z.I..I.~ .. .. ~.. . ..Z ......... ........... Florida Power CORPORATION June 13, 2000 JTB Pools SUBJECT: PROPOSED SPA/SWIMMING POOL CONSTRUCTION AT: 6952 OAK CREST WAY ZEPIIYRHILLS, FLORIDA Thank you for notifying us of your proposed swimming pool construction at the above location. The pool proposed for construction at the above address does not conflict with any underground or overhead facilities of Florida Power Corporation, provided that the pool is installed in the location shown on the attached site plan provided to us by the pool contractor. Please call Sunshine State One Call of Florida (1-800-432-4770) a minimum of 48 hours before you dig. If you have any questions or require any additional information, please call our office at (813) 783-6944. Sincerely, FLORIDA POWER CORPORATION Stephen F. Bunner Distribution Engineering SFB: mw ZEPHYR HILLS OPERATIONS CENTER: 36453 Eiland Boulevard. Zephyrhills, Florida 33541 A Rorida Progress Company 04#11\.__ S : ;:O~Vl.j- {3...~-I~ F;-e/ /, '1 S- 2 D4J( ~~.. f./...)t"t7 2<1(,;1, ,'/ (5 C!-JV~'fI'" ;-r t3 pO'> ( aJ. f/A<A. f ) Yk ,,-I{ (~13) 71'/-- t 2-91 7 /2- () 3 ) 7 " " ..-'" \ 1 0' UTILITY EASEMENT , , I I , I ~_~_~~?_5 ' 26" E I --------:--- - -J , , ---- ------ ---- I I l~ IU I I I I I I I I , PL.OT PL.AN SCAt..E:: I~ = 30'-0- 10' BUFFER EASEMENT I I , 12 ~ ~AI @ . AN' 12" )6 City of Zephyrhills Building Department 5335 Eighth Street Zephyrhills. Florida 33540 (813) 788-6611 Fax (813) 788.5262 W.A. "B"I Burgees Director of Building Ucenslnll & Zoning National Electrical Code 680-6{ )(2)" Receptacles shall be at least 10' from and not more than 20' from a .. the inside wall of the pool 680-6{ )(3): All 125-volt receptacles located within 20t of pool shall be GFCI a protected Standard Swimming Pool Code Where a wall of a dwelling serves as part of the barrier. All doors with direct access to the pool through that wall shall be equipped with an alarm which produces an audible alarm warning when the door and its screen are opened. The alarm shall sound continuously for a minimum of 30 seconds immediately after the 315.2..1.9: door is opened and be capable of being heard throughout the house during normal household activities. The alarm shall automaticaUy reset under all conditions. The alarm shalf be equipped with a manual means to temporarily deactivate the alarm for a single opening. Such deactivation switch shall be located at least 54 inches above the threshold of the door. City of Zephyrhills Building Department 5335 Eighth Street Zephyrhills, Florida 33540 (813) 788-6611 Fax (813) 788..5262 W.A. "Bill Burgess Director of Building Licensing & Zoning National Electrical Code 680-6{ )(2)" Receptacles shall be at least 10' from and not more than 20' from a " the inside waU of the pool 680-6(a)(3): All 125-volt receptacles located within 20' of pool shall be GFCI protected Standard Swimming Pool Code Where a wall of a dwelling serves as part of the barrier. All doors with direct access to the pool through that wall shall be equipped with an alarm which produces an audible alarm warning when the door and its screen are opened. The alarm shall sound continuously for a minimum of 30 seconds immediately after the 315.2.1.9: door is opened and be capable of being heard throughout the house during normal household activities. The alarm shall automaticalfy reset under all conditions. The alarm shall be equipped with a manual means to temporarily deactivate the alarm for a single opening. Such deactivation switch shall be located at least 54 inches above the threshold of the door. J T ~ (813) 782-0357 POOL CONTRACTING Custom Pools and Spas -~.~~=~=~_,~~=~~-~~~==="~~~===-~= . __' =- C-~~_~~~_=~--<-:=: -:=~.=--- :-_~=.____f=~=--=-.=- -~= L.:.=-= .~:.= n=-._~: .=."==---:_:=~= .---=~=~._-== ...-. -----..-~--._. -.--+--r-.----.~---.-. -- ---...--..-. --' --- , , f~- ,~-----. . -'--'-~---------,,-- ~..._-_._.._---. ..-~~-- - .. ,-+-- 1'.... -~---- --'~-----------:-'-'--_:_---~-~-' -+--_~_~=.=_.~4__:,~ ~_~_ ';'.- _.______._. , ~...... .~.. ---" -- MAP (N.T,S.) ;... S~p ~ 1.e, , .....<(S1;.-J ') y c,ol'c... 10:7 E'foi)r;'" I " \'\ ,~ ,\ }~"" ~ \ :ft.-.t 5 1. /-" ;I tr c./,',r^"" Z ('i (A 1- OVL ~ "\ cD ~C) ~ R~ , ( /' ~ ,-" \) ---:- ~J.- ,,- .; I 0 " ,~ ~- '-~~--------_..._- SCALE 1/8" = 1 '0" GENERAL SPECIFICATIONS JOB NO, SIZE IV SF ;2 7 3 SHAPE M~ &r"\. 3' TO (.. TEMP NO. x lff' DEPTH PER ~ ~ POOL CAPACllY rut-, /2, do 0 GALS FILTER Ci4a (2-0 SQ. FT, PUMP H,P' / Tl LE ..6RlCl<&~..~n i e ve--- , { L- r; i '; sa FT. D.O,D, e 5 3 b / 3 0 0 W\TTS DECKING C.{ FOOTERS 8' g ( UGHT e S LADDER _ SKIMMER 4t-5 RETURN UNES QTY. ELECTRICAL HOOKUP ~ MUNICIPAUlY 0 0 f SET BACKS: SIDE REAR I 0 NOTES: ("i C ~ c: ( ..( DESIGNER DATE SWIMMING POOL LOT BOOK , ._._._~-:----- -.--,.-- ,--~-~-~-;-___'__' -- ,',_____.__.____.__ -_-<0--___.;-" GENERAL SPECIFICATIONS J T ~ (813) 782-0357 POOL CONTRACTING Custom Pools and Spas n ~~~~~__~:~_.___'_n t-_~~:_=-~~__===-i-:-:=-==_ --_L__=~__'~_ , - .-.- -,_. - .'- -_.-- . _..------._------._-- JOB NO. SIZE / r SF ;2 7 3 x lff' DEPTH PER ~ C SHAPE M~ &..... 3 I TO C. TEMP NO. -- -~.-...;.' -- rf.J'/-, /2, do 0 GALS FILTER 64a LO sa FT, PUMP H,P' I TILE -6RtC1<&~'-"n i eve--- DECKING Co{ ~? 1 SQ FT, FOOTERS ~ ~ ( 0.0.0, e 5 3 b ( UGHT e. 5 :3 0 0 MTTS S MAP (N.T.S,) ! S~? ;... LADDER - ""'o{' ". ~.( s'f i"" 7 .;:; coi'c.. f07 t-,t.i)r;" (\"~" SKIMMER ~5 RETURN LINES QTY. :;<. ELECTRICAL HOOKUP UNDERWATER VACUUM W/HOSE MUNICIPAUTY 0 0 I SET BACKS: SIDE REAR ) 0 -----.:: .\ V'" ~ \ ::JL-.f 5 1. f" I ( Z r';' (^ ~tD / R . ~--~ ({) ~ ~~rr , I "./ ! y/ NOTES: .~ ''\ / .-- ,..--, '-' ..- ....j-""'" ....~---~--_.- ~.:::, ~ 'i' ~- '" ./ I 0 ., , DESIGNER DATE SWIMMING POOL' LOT BOOK SCALE 1/8" = 1'0"