Loading...
HomeMy WebLinkAbout00-9585 BUILDING PERMIT - CITY OF ZEPHYRHILLS (813) 788-6611 Permit 09585 J.f Date 6-~o-o() BUILDING ;2~ ELECTRICAL ~ ~ Pmperty owneCIJ~/;f~, 4 m~G6??~M Job Address: ~ --5-0 ~q1- I g 1/ ~../. Parcell.D. # /J- c:;1/P - c:21-() 0/1)- / n 900 - IJ /"/D Sewer Conn Water Conn: Water Meter: T.I.F.'s: ~'\. j FINAL .3-20-?:J / DATE NO OCCUPANCY BEFORE C.O. Complete Plans. Specifications and Fee Must Accompany Application. All work shall be performed in accordance with City Codes and Ordinances. c.o. DATE Inspector :s:e ~ ,()t.J ~~~~;,~~".>ft(;{~ @P.J& Company Address ~Phon~:V 8/3 -301- 4717 ,Yl~/P<'~' . GECTRI~t2Z7 PL~--- ..r' Valuation o~ 'If 000 II> ~ Contract Price City License Registration # W Co";!;od Uconso' Z~ ME.Q:;l '\~JICAL -- Ftr. Pre SLB Lintel FRM. Insul. CL WL Tp. Servo Rough In Meter Can Const. Pole Pool Pre-Meter Final SLB Tub Set Water Sewer Final Breakers Ducts Insl. Compressor Final Driveway REINSPECTION FEES: When extra inspection trips are necessary due to anyone of the following reasons. a charge of Fifteen and 00/100 Dollars ($ 25.001 shall be made for each trip for each trade: a. Wrong Address b. Condemned work resulting from faulty construction. c. Repairs or corrections not made when inspection called. d. Work not ready for inspection when called, e. Permit not posted on job site. f. Plans not at job site. g. Work not accessible. The payment of inspection fees shall be made before any further permits will be issued to the person owning same. APPLICATION FOR PERMIT CITY OF ZEPHYRHILLS BUILDING DEPARTMENT 1\ ';-), l ;, /.~'l, . OWNER'S NAM~~f\ k ~c ~I\W . JOB ADDRESS.~ Y- \R~ ~"("'-'----.....z yRI~;L.-L.$ J l!..t ~ I f- LEGAL DESCRI PTION: LOT (S) S'~n4 ~ i= N \k. BLOCK I Clq PARCEL 10 # \ l :J..C-. ~ I C)n[() \ OQDO OP-fC) DATE RECEIVED , PLANS rEW FEE ~&')?s:~ t=1-.. - I . SUBDIVISION\cw\l.> OF ftRty/'q-\;IJ,.<; \?B J ~5L.{ WORK PROPSED: ~NEW CONSTRUCTION []SIGN PROPOSED USE:~SGL FAMILY DWELLING [] COMMERCIAL {OBTAIN FROM PROPERTY TAX NOTICEl []ADDITION [] ALTERATI ON [] REPAIR [] INSTALL DMOVE D DEMOLISH []MULTI-FAMILY D INDUSTRIAL []# OF UNITS [] SWIMMING POOL [] MOBILE HOME [] OTHER DESCRIPTION OF o RESTAURANT & HEALTH DEPARTMENT APPROVAL .a- rr m ' WORK ~~~LL V~("'\L ( ~'e:cVe:. ~R.a: ,\.)~ FYI5//)..,(:T e# .-L/<- . I ~ Fffi-l!-E Ll ' :17 1)i A. SQUARE FOOTAGE HEIGHT -.J BUILDING SIZE RESIDENTIAL: COMMERCIAL: ATTACH (2) PLOT PLANS & (2) SETS OF BUILDING PLANS & (1) SET ENERGY FORMS. ATTACH (3) SETS OF BUILDING PLANS & (1) SET ENERGY FORMS. . V PROPERTY SURVEY REQUIRED FOR ALL NEW CONSTRUCTION. ~ IP: ~ {! ~ I? - O':4,} PERMITS REQUESTED &~1 L/- [] BUILDING $ t:,OD - VALUATION OF 1'0TAL CONSTRUCTION [] ELECTRICAL AMP SERVICE [] FLORIDA POWER [] W.R.E.C. [] PLUMBING D MECHANIeAL $ VALUATION OF MEeHANCIAL INSTALLATION o GAS D ROOFING D SPECIALTY D OTHER TYPE OF CONSTRUCTION: [] BLOCK [] FRAME [] STEEL o OTHER FINISHED FLOOR ELEVATIONS IS PROJECT IN FLOOD ZONE AREA[] YES Q!l NO f) 'L)~ER STATE CERT OR REGIST # CITY PROCESSING # BUILDER 4. SIGNATUR' . L(j.K~ntof(') COMPANY ****************************************************************** ELECTRICIAN ~ SIGNATURE ~. y A.,- ~ COMPANY fJ~ &v~ STATE CERT OR REGI ST # ce. 0"0 I z..t.1r CITY PROCESSING # ~37 ****************************************************************** PLUMBER COMPANY STATE CERT OR REGIST # CITY PROCESSING # SIGNATURE MECHANICAL **********~******************************************************* eOMPANY STATE CERT OR REGIST # CITY PROCESSING # SIGNATURE ***************************************************************** OTHER COMPANY STATE CERT OR REGIST # CITY PROCESSING # SIGNATURE ***************************************************************** CONDITIONS OF' PERMIT AFFIDAVIT A. ,NOTICE OF DEED RESTRICTIONS The undersigned understands that this permit may be subject to "deed restrictions" which may be more restrictive than City regulations. The undersigned assumes responsibility for compliance with any applicable deed restrictions. B. UNLICENSED CONTRACTORS AND CONTRACTOR RESPONSIBILITIES If the owner has hired a contractor or contractors to undertake work, they may be required to be licensed in accordance with state and local regulations. If the contractor is not licensed as required by law, both the owner and contractor may be cited for a misdemeanor violation under state law. If the owner or intended contractor are uncertain as to what licensing requirements may apply for the intended work, they are advised to contact the City of Zephyrhills Building Department, 813-788-6611. Furthermore, if the owner has hired a contractor or contractors, he is advised to have the contractor(s) sign portions of the "Contractor Sections" of this application for which they will be responsible. If you, as the owner signs as the contractor, you are indicating that you, rather than the contractor, are responsible for the work. If the contractor wishes you to sign as contractor that may be an indication that he is not properly licensed and is not entitled to permitting privileges in the City of Zephyrhills. C. TRANSPORTATION IMPACT FEES AND UTILITY CONNECTION FEES D. CONSTRUCTUION LIEN LAW (CHAPTER 713, FLORIDA STATUTES, AS AMENDED) I certify that I, the applicant, have been provided with a copy of "Florida's Construction lien Law - Homeowner's Protection Guide" prepared by the Florida Department of Agriculture and Consumer Affairs. If the applicant is someone other that the "owner", I cerify that I have obtained a copy of the above described document and promise in good faith to deliver it to the "owner" prior to commencement. E. CONTRACTOR'S/OWNER'S AFFIDAVIT I certify that all the information in this application is accurate and that all work will be done in compl~ance with all applicable laws regulating construction, zoning, and land development. Application is hereby made to obtain a permit to do work and installation as indicated. I certify that no work or installation has commenced prior to issuance of a permit and that all work will be performed to meet standards of all laws regulating construction, City codes, zoning regulations, and land development regulations in the jurisdiction. I also certify that I understand that the regulations of other governmental agencies may apply to the intended work, and that it is my responsibility to identify what actions I must take to be in compliance. Such agencies include but are not limited to: *Department of Environmental Regulation-Cypress Bayheads, Wetland Areas and Environmentally Sensitive Lands, Water/Wastewater Treatment *Southwest Florida Water Management District-Wells, Cypress Bayheads, Wetland Areas, Altering Watercourses *Army Corps of Engineers-Seawalls, Docks, Navigable Waterways *Department of Health & Rehabilitative Services, Environmental Health Unit-Wells, Wastewater Treatment, Septic Tanks *U.S. Environmental Protection Agency-Asbestos abatement I also certify that, if fill material is to be used in Flood Zone "A" or "A, etc.", it is understood that a drainage plan addressing a "compensating volume" will be submitted which is prepared by a professional engineer registered in the State of Florida prior to permit issuance. A permit issued shall be construed to be a license to proceed with the work and not as authority to violate, cancel, alter, or set aside any provisions of the technical codes, nor shall issuance of a permit prevent the Building Official from thereafter requiring a correction of errors in plans, construction, or violations of any code. Every permit issued shall become invalid unless the work authorized by such permit is commenced within six months of issuance, or if work authorized by the permit is suspended or abandoned for a period of six months after the time the work is commenced. One 90 day extension of time may be allowed for the permit with fee charge of $15.00. The extension shall be requested in writing to the Building Official. An approved inspection must be logged during each six month period, or the project will be considered abandoned. WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE REeORDING YOUR NOTICE OF COMMENCEMENT. JOBS UNDER $2,500 IN VALUE DO NOT NEED TO RECORD AND POST A "NOTICE OF COMMENeEMENT". SIGNATURE: OWNER OR AGENT SIGNATURE: CONTRACTOR acknowledged 19_ STATE OF FLORIDA COUNTY OF The foregoing instrument was Before me this _____day of by STATE OF FLORIDA COUNTY OF The foregoing instrument was Before me this _____ day of by acknowledged 19 (name of person acknowledged) Dwho is personally known to me, or (name of person acknowledged) [1ho is personally known to me, or of identification) take an oath. Dwho has produced (type of identification)" and who [Jdid Diid not take an oath D who has produced (type and who[J did [Jdid not Signature of person taking acknowledgement Signature of person taking acknowledgment Name typed, printed or stamped Name typed, printed or stamped I DONNA K. McDONALD 5634 - 18TH STREET ABOVE GROUND POOL , I , MAIN OR LIVING AREAl SQ. FEET I PRICE I I $ 40.00 I OTHER AREA UNDER ROOF $ 15.00 OTHER VALUATION $ - FEE SHEET ADDRESS $ - DRIVEWAY $ - BUILDING: $ 25.00 CREDIT: $ - BUILDING LESS CREDIT: $ 25,00 ELECTRICAL: $ 25_00 PLUMBING: $ - MECHANICAL: $ . RADON: $ - TOTAL $ 50.00 SEWER: $ - WATER: $ - IRRIGATION: $ - TOTAL: $ - I WATER METER:I $ - I IRRIGATION METER $ I TI ~I : . I 1% $ TOTAL: $ 50.00 f ..~... .-;...... i:~.4I:': \.~.~.z ......... ---.- Florida Power CORPORATION June 13, 2000 Ms. Donna K. McDonald SUBJECT: PROPOSED SPA/SWIMMING POOL CONSTRUCTION AT: 5634 ISm STREET ZEPHYRHILLs, FLORIDA Thank you for notifying us of your proposed swimming pool construction at the above location. The pool proposed for construction at the above address does not conflict with any underground or overhead facilities of Florida Power Corporation, provided that the pool is installed in the location shown on the attached site plan provided to us by the pool contractor. Please call Sunshine State One Call of Florida (1-800-432-4770) a minimum of 48 hours before you dig. If you have any questions or require any additional information, please call our office at (813) 783-6944. Sincerely, FlORIDA POWER CORPORATION \*~J4~/ Stephen F. Bunner Distribution Engineering SFB: mw ZEPHYRHILLS OPERATIONS CENTER: 36453 Eiland Boulavard . Zephyrhills. Rorida 33541 A Rorida Progress Company 1999 National Electrical Code 1::;' Swimmina Dools 680-6. Receptacles, Lighting Fixtures, Lighting Outlets, Switching Devices, and Ceiling-Suspended (Paddle) Fans (a) Receptacles. 1. A receptacle(s) that provides power for a water-pump motor(s) for, or other loads directly related to the circulation and sanitation system, a permanently installed pool or fountain, as permitted in Section 680-7, shall be permitted between 5 ft and 10 ft (1.52 m and 3.05 m) from the inside walls of the pool or fountain, and, where so located, shall be single and of the locking and grounding types and shall be protected by a ground-fault circuit interrupter(s). Other receptacles on the property shall be located at least 10 ft (3.05 m) from the inside walls of a pool or fountain. 2. Where a permanently installed pool is installed at a dwelling unites), at least one 125-volt 15. or 20-ampere receptacle on a general-purpose branch circuit shall be located a minimum of 10 ft (3,05 m) from and not more than 20 ft (6.08 m) from the inside wall of the pool. This receptacle shall be located not more than 6 ft 6 in. (1.98 m) above the floor, platform, or grade level serving the pool. 3. All 125-volt receptacles located within 20-ft (6.08 m) of the inside walls of a pool or fountain shall be protected by a ground-fault circuit interrupter. FPN: In determining the above dimensions, the distance to be measured is the shortest path the supply cord of an appliance connected to the receptacle would follow without piercing a floor, wall, ceiling, doorway with hinged or sliding door, window opening, or other effective permanent barrier. (b) Lighting Fixtures, lighting Outlets, and Ceiling-Suspended (Paddle) Fans. 1. In outdoor pool areas, lighting fixtures, lighting outlets, and ceiling-suspended (paddle) fans shall not be installed over the pool or over the area extending 5 ft (1.52 m) horizontally from the inside walls of a pool unless no part of the lighting fixture or ceiling-suspended (paddle) fan is less than 12 ft (3.66 m) above the maximum water level. 2. Existing lighting fixtures and lighting outlets located less than 5 ft (1.52 m) measured horizontally from the inside walls of a pool shall be at least 5 ft (1.52 m) above the surface of the maximum water level, shall be rigidly attached to the existing structure, and shall be protected by a ground-fault circuit interrupter. 3. In indoor pool areas, the limitations of Section 680-6(b)(1) shall not apply if all of the following conditions are complied with a, Fixtures are of a totally enclosed type, b. A ground-fault circuit interrupter is installed in the branch circuit supplying the fixture(s) or ceiling-suspended (paddle) fans, and c. The distance from the bottom of the fixture or ceiling-suspended (paddle) fan to the maximum water level is not less than 7 ft 6 in. (2.29 m). 4. Lighting fixtures and lighting outlets installed in the area extending between 5 ft (1.52 m) and 10 ft (3,05 m) horizontally from the inside walls of a pool shall be protected by a ground-fault circuit interrupter unless installed 5 ft (1.52 m) above the maximum water level and rigidly attached to the structure adjacent to or enclosing the pool. 5. Cord-connected lighting fixtures shall meet the same specifications as other cord- and plug-connected equipment as set forth in Section 680-7 where installed within 16 ft (4.88 m) of any point on the water surface, measured radially. (c) Switching Devices. Switching devices on the property shall be located at least 5 ft (1.52 m) horizontally from the inside walls of a pool unless separated from the pool by a solid fence, wall, or other permanent barrier. 680-7. Cord- and Plug-Connected Equipment Fixed or stationary equipment rated 20 amperes or less, other than an underwater lighting fixture for a permanently installed pool, shall be permitted to be connected with a flexible cord to facilitate the removal or disconnection for maintenance or repair. For other than storable pools, the flexible cord shall not exceed 3 ft (914 mm) in length and shall have a copper equipment grounding conductor not smaller than No. 12 with a grounding-type attachment plug. 680-10. Underground Wiring Location Underground wiring shall not be permitted under the pool or within the area extending 5-ft (1.52 m) horizontally from the inside wall of the pool unless this wiring is necessary to supply pool equipment permitted by this article. Where space limitations prevent wiring from being routed 5-ft (1.52 m) or more from the pool, such wiring shall be permitted where installed in rigid metal conduit, intermediate metal conduit, or a nonmetallic raceway system. All metal conduit shall be corrosion resistant and suitable for the location. The minimum burial depth shall be as follows. Wiring Method Rigid metal conduit Intermediate metal conduit Nonmetallic raceways listed for direct burial without concrete encasement Other approved raceways* Minimum Burial (in.) 6 6 18 18 680-12. Disconnecting Means A disconnecting means shall be provided and be accessible, located within sight from all pools, spas, and hot tub eqUipment, and shall be located at least 5 ft (1.52 m) from the inside walls of the pool, spa, or hot tub. 1994 Standard Swimmina Pool Code 315.2.1.9(1). All doors with direct access to the pool through that wall shall be equipped with an alarm which produces an audible warning when the door and its screen are opened. The alarm shall sound continuously for a minimum of 30 seconds immediately after the door is opened and be capable of being heard throughout the house during normal household activities. The alarm shall automatically reset under all conditions. The alarm shall be equipped with a manual means to temporarily deactivate the alarm for a single opening. Such deactivation shall last no more than 15 seconds. The deactivation switch shall be located at least 54 inches above the threshold of the door. 1999 National Electrical Code Swimmina Dools (a) Receptacles. 680-6. Receptacles, Lighting Fixtures, Lighting Outlets, Switching Devices, and Ceiling-Suspended (Paddle) Fans 1. A receptacle(s) that proVides power for a water-pump motor(s) for, or other loads directly related to the circulation and sanitation system, a permanently installed pool or fountain, as permitted in Section 680-7, shall be permitted between 5 ft and 10 ft (1.52 m and 3.05 m) from the inside walls of the pool or fountain, and, where so located, shall be single and of the locking and grounding types and shall be protected by a ground-fault circuit interrupter(s). Other receptacles on the property shall be located at least 10 ft (3.05 m) from the inside walls of a pool or fountain. 2. Where a permanently installed pool is installed at a dwelling unites), at least one 125-volt 15- or 20-ampere receptacle on a general-purpose branch circuit shall be located a minimum of 10 ft (3.05 m) from and not more than 20 ft (6.08 m) from the inside wall of the pool. This receptacle shall be located not more than 6 ft 6 in. (1.98 m) above the floor, platform, or grade level serving the pool. 3. All 125-volt receptacles located within 20-ft (6.08 m) of the inside walls of a pool or fountain shall be protected by a ground-fault circuit interrupter. FPN: In determining the above dimensions, the distance to be measured is the shortest path the supply cord of an appliance connected to the receptacle would follow without piercing a floor, wall, ceiling, doorway with hinged or sliding door, window opening, or other effective permanent barrier. (b) lighting Fixtures, Lighting Outlets, and Ceiling-Suspended (Paddle) Fans. 1. In outdoor pool areas, lighting fixtures, lighting outlets, and ceiling-suspended (paddle) fans shall not be installed over the pool or over the area extending 5 ft (1.52 m) horizontally from the inSide walls of a pool unless no part of the lighting fixture or ceiling-suspended (paddle) fan is less than 12 ft (3.66 m) above the maximum water level. 2. Existing lighting fixtures and lighting outlets located less than 5 ft (1.52 m) measured horizontally from the inside walls of a pool shall be at least 5 ft (1.52 m) above the surface of the maximum water level, shall be rigidly attached to the existing structure, and shall be protected by a ground-fault circuit interrupter. 3. In indoor pool areas, the limitations of Section 680-6(b)(1) shall not apply if all of the following conditions are complied with a. Fixtures are of a totally enclosed type, b. A ground-fault circuit interrupter is installed in the branch circuit supplying the fixture(s) or ceiling-suspended (paddle) fans, and c. The distance from the bottom of the fixture or ceiling-suspended (paddle) fan to the maximum water level is not less than 7 ft 6 in. (2.29 m). 4. Lighting fixtures and lighting outlets installed in the area extending between 5 ft (1.52 m) and 10 ft (3.05 m) horizontally from the inside walls of a pool shall be protected by a ground-fault circuit interrupter unless installed 5 ft (1.52 m) above the maximum water level and rigidly attached to the structure adjacent to or enclosing the pool. 5. Cord-connected lighting fixtures shall meet the same specifications as other cord- and plug-connected equipment as set forth in Section 680-7 where installed within 16 ft (4.88 m) of any point on the water surface, measured radially. (c) Switching Devices. Switching devices on the property shall be located at least 5 ft (1.52 m) horizontally from the inside walls of a pool unless separated from the pool by a solid fence, wall, or other permanent barrier. 680-7. Cord- and Plug-Connected Equipment Fixed or stationary equipment rated 20 amperes or less, other than an underwater lighting fixture for a permanently installed pool, shall be permitted to be connected with a flexible cord to facilitate the removal or disconnection for maintenance or repair. For other than storable pools, the flexible cord shall not exceed 3 ft (914 mm) in length and shall have a copper equipment grounding conductor not smaller than No. 12 with a grounding-type attachment plug. 680-10. Underground Wiring Location Underground wiring shall not be permitted under the pool or within the area extending 5-ft (1.52 m) horizontally from the inside wall of the pool unless this wiring is necessary to supply pool equipment permitted by this article. Where space limitations prevent wiring from being routed 5-ft (1.52 m) or more from the pool, such wiring shall be permitted where installed in rigid metal conduit, intermediate metal conduit, or a nonmetallic raceway system. All metal conduit shall be corrosion resistant and suitable for the location. The minimum burial depth shall be as follows, Wiring Method Rigid metal conduit Intermediate metal conduit Nonmetallic raceways listed for direct burial without concrete encasement Other approved raceways* Minimum Burial (In.) 6 6 18 18 680-12. Disconnecting Means A disconnecting means shall be provided and be accessible, located within sight from all pools, spas, and hot tub equipment, and shall be located at least 5 ft (1.52 m) from the inside walls of the pool, spa, or hot tub. 1994 Standard Swimmina Pool Code 315.2.1.9(1). All doors with direct access to the pool through that wall shall be equipped with an alarm which produces an audible warning when the door and its screen are opened. The alarm shall sound continuously for a minimum of 30 seconds immediately after the door is opened and be capable of being heard throughout the house during normal household activities. The alarm shall automatically reset under all conditions. The alarm shall be equipped with a manual means to temporarily deactivate the alarm for a single opening. Such deactivation shall last no more than 15 seconds. The deactivation switch shall be located at least 54 inches above the threshold of the door.