Loading...
HomeMy WebLinkAbout00-9611 BUILDING PERMIT CITY OF ZEPHYRHILLS (813) 788-6611 09611 Date 711lloD Permit "i C, .~, q.9 BUILDING '7 ~, t} ELECTRICAL b;J. ~ PLUMBING r cu SJ ,- MECHANICAL \l ()(:' Sewer Conn I) 70'- - ~J#. Water Conn: lbO,- . .q oJ Water Meter: ,IJO, .- q-~' . ,Y' .';. 115, '.1.' J le). c~. , I. . / Property Owner: \, 4r, [,_0., S J.-. Job Address: ~7 400 y,'<-k-e H- s ,It-\.. 1I ~ Parcell.D. # 03 '-')6.. ~ 1- O~Ov' ()4>OO(1- Of:;, ~o T.I.F.'s: - Zoning: Descriotion of Work Energy Code: 5;"7'P k.;'\;l:ty I:~O Dci~",E' IJ!'o Radon Gas: DweU,'''5 /8. !l c.rfie?i f f' P,e ~"""'e* NO OCCUPANCY BEFORE C.O. FINAL Complete Plans, Specifications and Fee Must Accompany Application. C.O, All work shall be performed in accordance with City Codes and Ordinances. Inspector City License Registration # State Certified License# Permit Fee -'Signature Company Address Telephone# ~~Vo-t Valuation or Contract Price 57760, ov , V~rl {':II'" 5-1-. BUILDING 5~ fk-\ p~; 0'\ ~~fer fr: ~~~ ELECTRICAL lib"" ~r\I\; ~ W:": llr"'\'l S q-,~ L ~57 -Do If"-:'" 4:; ~ 5~ S MECHANICAL 113 ( PLUMBING (l12o SLB C;..f-O(J) ~,e TubSet //-Ib-Ot:> .5l12... Water 1.1 r/ D-&!I / ~ Sewer Lf - (0 ... C> I ~ Final Breakers Ducts Insl. /J- /6, PO Stf:.... Compressor Final Ftr, &- ~OO S ~ Pre SLB v/#-(!)I) ') Lintel FRM, /1,/ ./:i-a 0 S'/C.. Insul. CL WL J.rl1J~na: _--J~ ~;;~ Tp. Servo Rough In j}-Ib -1'0 '5'~ Meter Can Const. Pole Pool Pre-Meter 4-/<) 0f ,.. fl Final f~ ~ S-9-(J)().sf( REINSPECTION FEES: When extra inspection trips are necessary due to anyone of the following reasons, a charge of Fifteen and 00/100 Dollars ($ 25.001 shall be made for each trip for each trade: a. Wrong Address b, Condemned work resulting from faulty construction. c, Repairs or corrections not made when inspection called, d. Work not ready for inspection when called. e, Permit not posted on job site. f, Plans not at job site. g, Work not accessible, vJ r-.. ~.rf. As tof!1t-- } pc. (rJ ( u Irs Iou The payment of inspection fees shall be made before any further permits will be issued to the person owning same. .. . ...i.-i .i.i Date Received B) ----- --------------------------------------------------------------------------------------------------------------------------------------------- OFFICE L'SE ONL Y TRANSPORTATION REC. NO. '7'l flf():<" RESOURCE RECOVERY REC. NO. DATE DATE White Applicant Canary Trans/Finance Canary RR/Finance feecai"ce PC93113094/D / c?j I{-;d BB~ ~~-' Pink Of lice Green Bldg/lnsp (At I ,~,I,;.., rM) / \ 0!!:!)) APPLICAnON FOR PEBMI~ \ 0-- t CITY 01' ZEPHYRHILLS ~ I O~ . BUILDr~'lG DEPARTMENT \~~~lTE RECEIVED ",2/- aO trY PLANS REVIEW FEE 113 Z<,; 5J J7'bo OWNER'S NAME SUBDIVISION JOB ADDRESS PARCEL ID # BLOCK O()ooo 3 'l..-~ L-f. Dl~) CVoDO ('j.d')() ~W CONSTRUCTION (OBTAIN FROM PROPERTY TAX,NOTICE) LEGAL DESCRIPTION: LOT(S) WORK PROPSED: o ADDITION o ALTERATI ON o REPAIR o INSTALL Os I GN o MOVE 0 DEMOLISH PROPOSED USE~GL FAMILY DWELLING DMULTI-FAMILY D# OF UNITS D MOBILE HOME D COMMERCIAL D INDUSTRIAL o SWIMMING POOL o OTHER DESCRIPTION OF WORK ~c:J RESTAUjT & H~H DEPARTMENT APPROVAL l-e.1ivv\ f?L t=b1"A ~ A SQUARE FOOTAGE t.1/) '677 t;::~ . ATTACH (2) PLOT PLANS & (2) SETS OF BUILDING PLANS & (1) SET ENERGY FORMS. ATTACH (3) SETS OF BUILDING PLANS & (1) SET ENERGY FORMS. PROPERTY SURVEY REQUIRED FOR ALL NEW CONSTRUCTION. BUILDING SIZE HEIGHT RESIDENTIAL: COMMERCIAL: PERMITS REQUESTED ~BUILDING $-&() 006 '2 -,r ~ L OV' AMP VALUATION OF TOTAL CONSTRUCTION '-q- ELECTRICAL SERVICE ~ FLORIDA POWER o W.R.E.C. 'If PLUMBING ~d' 00 9' MECHANICAL $ C,J=/;;:J- D GAS fROOFING D SPECIALTY TYPE OF CONSTRUCTION: D BLOCK VALUATION OF MECHANCIAL INSTALLATION o OTHER ~RAME D STEEL D OTHER FINISHED FLOOR ELEVATIONS IS PROJECT IN FLOOD ZONE AREAD YES J('" NO BUILDER ~ COMPANY STATE CERT OR REGIST CITY PROCESSING # SIGNATURE ****************************************************************** ELECTlUCIAN ~ .Q& SIGNATURE . ~ ~ 'D\' -i_' :-f-tL COMPANY i) 0 h,~ I;:-~VqJ'2tZ~~ . STATE CERT OR REGIST # fa.. -LU:.:Q 5<0(:." CITY PROCESSING # IJ7~ PLUMBER Q* * * * * * * * * * * ** * * *~* ** * *~* H H * *** * H * :::::: * H ~;*~:; * *~ *~i~ :~~~ Mb,~ . . / or STATE CERT OR REGIST # .F: 0 2 ./':C) SIGNATURE .~ --ii::..-- 12. CITY PROCESSING # j ~l. u V' '" ***********.*********** ** ********** ****** ** ************** *l'':.t*''''***tt 5 J , MECHANICAL ~ COMPANY Ut+lli I ~ jjl (l. (/Jt~ n fill STATE CERT OR REGIST # ~ SIGNATURE . ~ ~ J1J~ CITY PROCESSING # ~ ~ ***** *********************************************************** COMPANY \!fTil STATE CERT OR REGIST # CITY PROCESSING # o ..-1 l OTHER SIGNATURE ********************************************************~-******** \"..U.L'IIIJ..l..l.l.Ui\l.:.> U.t .t'~.KlY1J...1. J-\..r~.l.1JJ-\..V.1..1 A. NOTICE OF DEED RESTRICTIONS The undersigned understands that this permit may be subject to ~deed restrictions" which may be more restrictive than City regulations. The undersigned assumes responsibility for compliance with any applicable deed restrictio~s. B. UNLICENSED CONTRACTORS AND CONTRACTOR RESP)NSIBILITIES If the owner has hired a contractor or contractors to undertake work, they may be required to be licensed in accordance with state and local regulations. If the contractor is not licensed as required by law, both the owner and contractor may be cited for a misdemeanor violation under state law. If the owner or intended contractor are uncertain as to what licensing requirements may apply for the intended work, they are advised to contact the City of Zephyrhills Building Department, 813-788-6611. Furthermore, if the owner has hired a contractor or contractors, he is advised to have the contractor(s) sign portions of the ~Contractor Sections" of this application for which they will be responsible. If you, as the owner signs as the contractor, you are indicating that you, rather than the contractor, are responsible for the work. If the contractor wishes you to sign as contractor that may be an indication that he is not properly licensed and is not entitled to permitting privileges in the City of Zephyrhills. C. TRANSPORTATION IMPACT FEES AND UTILITY CONNECTION FEES D. CONSTRUCTUION LIEN LAW (CHAPTER 713, FLORIDA STATUTES, AS AMENDED) I certify that I, the applicant, have been provided with a copy of ~Florida's Construction lien Law - Homeowner's Protection Guide" prepared by the Florida Department of Agriculture and Consumer Affairs. If the applicant is someone other that the ~ownerff, I cerify that I have obtained a copy of the above described document and promise in good faith to deliver it to the ~owner" prior to commencement. E. CONTRACTOR'S/OWNER'S AFFIDAVIT I certify that all the information in this application is accurate and that all work will be done in compliance with all applicable laws regulating construction, zoning, and land development. Application is hereby made to obtain a permit to do work and installation as indicated. I certify that no work or installation has commenced prior to issuance of a permit and that all work will be performed to meet standards of all laws regulating construction, City codes, zoning regulations, and land development regulations in the jurisdiction. I also certify that I understand that the regulations of other governmental agencies may apply to the intended work, and that it is my responsibility to identify what actions I must take to be in compliance. Such agencies include but are not limited to: *Department of Environmental Regulation-Cypress Bayheads, Wetland Areas and Environmentally Sensitive Lands, Water/Wastewater Treatment *Southwest Florida Water Management District-Wells, Cypress Bayheads, Wetland Areas, Altering Watercourses *Army Corps of Engineers-Seawalls, Docks, Navigable Waterways *Department of Health & Rehabilitative Services, Environmental Health Unit-Wells, Wastewater Treatment, Septic Tanks *U.S. Environmental Protection Agency-Asbestos abatement I also certify that, if fill material is to be used in Flood Zone ~A" or ~A,etc.", it is understood that a drainage plan addressing a ~compensating volume" will be submitted which is prepared by a professional engineer registered in the State of Florida prior to permit issuance. A permit issued shall be construed to be a license to proceed with the work and not as authority to violate, cancel, alter, or set aside any provisions of the technical codes, nor shall issuance of a permit prevent the Building Official from thereafter requiring a correction of errors in plans, construction, or violations of any code. Every permit issued shall become invalid unless the work authorized by such permit is commenced within six months of issuance, or if work authorized by the permit is suspended or abandoned for a period of six months after the time the work is commenced. One 90 day extension of time may be allowed for the permit with fee charge of $15.00. The extension shall be requested in writing to the Building Official. An approved inspection must be logged during each six month period, or the project will be considered abandoned. WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR L ER OR AN ATTORNEY BEFORE RECORDING YOUR NO CE OF COMM~,NCEMENT' JOBS UNDER $2,500 IN V DO NOffEE~ TO RECORD AND POST A "NOTICE 0 COMMENENTn. ,~ ~ (Y-- - SIGNATURE: OWNER OR AGENT SIGNATURE: CONTRACTOR STATE OF FLORIDA COUNTY OF The foregoing instrument was acknowledged Befo't) me this ~day of 1J'~1 , ~ by . O~I.\.L-- \lbA.I (name of person acknowledged) Owho is' personally known to me, or 'r/J-who has produced rt-- ~ 'I( ~ t;.J t (type of identification) did ot take an oath. P A:.t u'") STATE OF FLORIDA COUNTY OF The foregoing i~ent w~rOWledged Before me this ~day of , ~ by l:Yo '^ \Ah. ~, (name of person acknowledged) C1ho is personally known to me, or ~hO has produced ~, b~ \J' ..P--1.,,,,,' (type of identification) and Who't!did []did not take an oath P 1\-1 CC~ ignature of person taking acknowledgment ~ r\-.,:in tQ!WC~HQYNThbed MPiJi.'1:-1 MY COMMISSION # CC752204 ~'~;.~i EXPIRES: June 30,2002 "''Jf.iif.:f1.~'' lIQ!\ljed Thru Notary Public Underwriters Name t ~;rU rin tMi&E&~OW~1 d {:;..-ib.~:-: MY COMMISSION # CC 7 Sif4 ~."lI!k.:.: EXPIRES: June 30, 2002 ...'Ii(..."....:$-' Bonded Tnru Nollry PubliC UndllrwrltOrB ,Rrtlw Name t R RETURN TO: . . "IN, ALFONSO, & HERNANDEZ, p,A. P.O. BOX 4 :"JADE CITY. FLORIOA38526-0004 111111111111 1111I1111I1111I11111111" 1111111111 11111111I1111 . 2000061216 NOTICE OF COMMENCEMENT Repl: 413903 DS: 0.00 05/16/00 Ree: 6.00 IT: 0.00 Dpty Clerk STATE OF FLORIDA ) COUNTY OF PASCO ) THE undersigned, as Owner, notifies all parties that improvements will be made to certain real property, and in accordance with Section 713.13, Florida Statutes, the following information is stated in the Notice of Commencement: DESCRIPTION OF PROPERTY: Lot 12,@ 27 an~ilver Oaks Village - Phase One, as recorded in Plat Book 35, Pages 63 through 67, Public Records of Pasco County, Florida. GENERAL DESCRIPTION OF IMPROVEMENTS: C/ B Home OWNER AND OWNER'S ADDRESS: V ARI Construction Services, Inc. 23110 SR 54 #106 Lutz, Florida 33549 OWNER'S INTEREST IN THE PROPERTY DESCRIBED AS: Simple CONTRACTORS AND CONTRACTOR'S ADDRESS: V ARI Construction Services, Inc. 23110 SR 54, No. 106 Lutz, Florida 33549 SURETY (if any) and SURETY ADDRESS: N/A AMOUNT OF BOND: $ N/A NAME AND ADDRESS OF LENDER, IF ANY, MAKING A LOAN FOR CONSTRUCTION OF THE IMPROVEMENTS: Community National Bank of Pasco County Post Office Box 639 Zephyrhills, Florida 33539 JED PITTMAN1 PASCO COUNTY CLERK 05/16/00 0~:0!rm 1 of 1 OR BK 436 t PG 1399 NAME OF PERSON WITHIN THE STATE OF FLORIDA DESIGNATED BY OWNER UPON WHOM NOTICES OR OTHER DOCUMENTS MAYBE SERVED: Community National Bank of Pallco County Post Office Box 639 Zephyrhills, Florida 33539 IN ADDITION, OWNER DESIGNATES THE FOLLOWING PERSON TO RECEIVE A COpy OF THE LIENOR'S NOTICE AS PROVIDED IN SECTION 713.13, FLORIDA STATUTES: Community National Bank of Pasco County Post Office Box 639 Zephyrhills, Florida 33539 Larry Hersch Attorney at Law Post Office Box 1046 Dade City, Florida 34297-1046 \,,~ .. I , '11'1 \\ 1 "I ( :.." " J '. "". ,.,' ......~. 4.. . . ...... , . .." '. J ~". . : -or- ..-_' Cr.. ! ;:~: .: <~n:.~ ~.: .,: (.I w(ftc\~ \ . ': ~........ po.- r-Ji : ::. ) 00 <SO (j) ..... ~ ~." ... ,., ..... , .'. .. '.. J. V ARI, III, PREsnjE~ I ,;"~'. \'~' ,;.\...,. . """,...., I'" ,.,., EXPIRATION DATE: Mav 15. 2001 STATE OF FLORIDA COUNTY OF PASCO The foregoing instrument was acknowledged before me this 15th day of May,2000, by FRANCIS J. V ARI, III, PRESIDENT, who is personally known to me or ~~.~~ as identification, and who 11M/did not take oath. Witness my hand and official seal in the County and State last aforesaid this 15th, day of May, 2000. ...~Y PlI OfRClAlNOTNlYSEAL O.....C9~ JEIItlIFERKWARD ,.. COt.lMISSION NUMBER . ~ CC842252 .,.~o o~ MY CClMUISSION EXP1RES F f\.: JUNE 1 2003 gb~~~~FOFLORIDA F PASCO THIS IS TO CERT ;~~F~~Bf~R~:gb~O~~YO~~~ :t~~:Z?ING IS A H~ NO OFFICIAlO ~~:~/~H~~'-~Ii:~F~~ JED 2Ctt'?J AYOF AN, elE ~ BY . CIRCUIT COURT EPUTY CLERK VARI CONST. 37400 PICKETTS MILL AVE. SQ. FEET PRICE MAIN OR LIVING AREA 1,185 $ 40.00 OTHER AREA UNDER ROOF 692 $ 15.00 OTHER VALUATION $ 57,780.00 FEE SHEET $ 302,00 ADDRESS $ 20.00 DRIVEWAY $ 20.00 BUILDING: $ 493,00 CREDIT: $ - BUILDING LESS CREDIT: $ 493.00 ELECTRICAL: $ 78.12 PLUMBING: $ 62.50 MECHANICAL: $ 35.00 RADON: $ 18.77 TOTAL $ 687,39 SEWER: $ 1,278,00 WATER: $ 350.00 IRRIGATION: $ 175.00 TOTAL: $ 1,803.00 WATER METER: $ 180.00 IRRIGATION METER $ 180.00 I TIF'S'r 99% $ 1% $ : I TOTAL: $ 2,850.39 I ~ C'l ::0 Z c:! CJ) en ~ Rl~ J. ~ :I: m CJ) :I: m m ~ ~ ::0 c: m C'l Z -l ~ r= Zz ~ llo~ ~ ::0 " ~ 0 0 Z -1m m 1- ~ m ~ z ~ () G> mJJ JJ ~::o m iT! m CJ) m JJ ...., ~ "-I" ::. -l ::0 -l m CJ) )> mg m m ~ m () ::0 ::0 ~ 0 ~ C'l~ C'l 0 :-l 0" .~ m C'l JJ Z ~Fii m -. m - ~ 0 en ~m '\ en 0 "1l c~ ....r> m :II 0 0 0 \ ~ 0 p ~ ~ ~ z r-- (') 0 m ....] ~ ~ v, N=i a> c \"" m< {11 - :I! 0 z m ~ 8l 0 ~." "1l i!:N :Il r-m 8 - fii." c 0 -::t .iIl ~< z 0:0 p ~ :!!::t CD g;= ;;; ~ i ::0 ~ G> ~ ~ m ..Jo ~ Z z t-~ ~ 0 0 ~ 0 ~ ~ I I I I I I ~ CD -. m ~ t ~ Rl -. C'l ~ nl -J ;; II: ~ ~ Ii: ~ C'l ::j ~ ~ ~ -< ::0 ::0 Ui ~ ~ ;; p 0 C! ~ m I c: n z (II ~ ~ ~ -l ~ c: ~ D ~ ~ z ;j ~ I:::'\. Ii) 0 ~ m c: "-, l:D ~ ;: ~ -, ~ ~ C'l ~ Z c:! ~ en ~ ~~ ~ -., :I: ~ m m ~ c: -C m C'l -l ~ r= ~ llo~ ::0 " ~ 0 ~ Z -1m m ,~ ~ C'5 JJ ~ m 3: z G> mJJ ~j! m iT! m m m JJ....... ~ iT! ::0 iT! CJ) )> ~ ~ m mC'l ::0 ::0 ~ 0 () g~ C'l 0 :-l m JJ Z 3:~ ~ m m 0 -. ~iT! en en ;rlc ;R c~ :? :II 0 0 0 ~ ~ 0 ~ ~. ~ z (') 0 "'l m N=i a> m< ~ :I! 0 z ~ ~ () ~." "1l i!:N :Il r-m 8 -. fii." c 0 ~::t pj 5~ z J p ~ :!!::t CD g;= ~ ~ ~ :::J ::0 r- t ~ r--.. en -.., m ~ z 0 :\ 0 0 0 !!! 1 1 1 I 1 I 1- ~ ~ CD 0 ~ CJ) m ~ t c: z m -l C'l ~ -i ;; - II: ~ ~ c ~ C'l ::j ~ ~ ~ m ::j -< ::0 !'<o -........t' ;if i ... ~ -< m ~. c: p....;, n z c: ~ f:j ~ -l -l ~ ~ z 8' ~, i! ;j m g l:D z ~\ ;: -l ') CURVE #/ : DELTA = 06017'01" CHORD BEARING = N-870I2'21"-E RADIUS = 255,00' ARC = 27,97' CHORD = 27.95' PIC1(CTT'S b N 5.5/8" IR aLe 6382 ~. z w ~ w II) i5 ~ :J i= ::;) b o c;j b o Iri rt) f~ iD ~ w 3 I N l{) b N ~ 0 0 I Z 2,0' 5, 5/8" IR #Le 6382 FD N 8 0 aLe 4281 PCP ~ MIL PC AVENUE 5-S9039'OS"-E 32.0 . PC CURVE #1 S. 5/8" IR aLe 6382 \ t'- ::r- -9r"JS,-1 00' .. ~ oJ G' '" ,I _ __ J',8--Lh ~_____~____._ t:: 9 ;1\ ~ \ 60.00' N-S9039'OS"_W S. 5/8" IR #Le 6382 ----- b Of N u - La b Pc C'I 5.5/8" \R w ...J LB 6382 <t u II) N< --- -- 1. 2. 3. 4. ~ "l <.D rt) 5, 6. 7. 8, W I N 10 b N o o o I Z al to I b ...J o tl) 1-0 -; 01 ~ II I I PREPARED BY: T' MA Pr Fl LB 1.80' NOT VALID UNLE RAISED SEAL FQP.M 600A-97 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Community Affairs Residential Whole Building Performance Method A - Project Name: Address: City, State: Owner: Climate Zone: -- _____.__._____n._______ Arlington II Model Lot:~, Sub: SOV, Plat: PB 1 PG 55 Zephyrhills, FI 33543- Vari Construction Services Central i. New construction or existing 2. Single family or multi-family 3. Number of units, if multi-family 4. Number of Bedrooms 5. Is this a worst case? 6. Conditioned floor area (fe) 7. Glass area & type a. Clear - single pane b. Clear - double pane c. Tint/other SC/SHGC - single pane d. Tint/other SC/SHGC - double pane 8. Floor types a. Raised Concrete b. N/A c. N/A 9, Wall types a. Frame, Wood, Exterior b. Frame, Wood, Adjacent c. N/A d. N/A e. N/A iO. Ceiling types a, Under Attic b. N/A c. N/A Ii. Ducts a. Sup: Unc. Ret: Unc. AH: Attic b. N/A New Single family I Yes 1190 ft' 128.3 ft' 0.0 ft' 0.0 ft' 0.0 ft' R=4.0, I] 90.0fe R= 11.0, 1234.5 ft' R=] 1.0,328.5 ft' R=30.0, ] i90.0 ft' Sup. R=6.0, 225.0 ft Builder: Vari Homes Permitting Office: Z.:Jfh., "'lIs Permit Number: 961( Jurisdiction Number: (PI/boo 12. Cooling systems a. Central Unit 3 b. N/A c. N/A ] 3, Heating systems a. Electric Heat Pump b. N/A c. N/A 14. Hot water systems a. Electric Resistance b. N/A c. Conservation credits (HR-Heat recovery, Solar DHP-Dedicated heat pump) is. HYAC credits (CF-Ceiling fan, CY-Cross ventilation, HF- Whole house fan, PT-Programmable Thermostat, RB-Attic radiant barrier, MZ-C-Multizone cooling, MZ-H-Multizone heating) Glass/Floor Area: 0.11 Total as-built points: 18416.00 Total base points: 21630.00 PASS Review of the plans and specifications covered by this calculation indicates compliance with the Florida Energy Code. Before construction is completed this building will be inspected for compliance with Section 553.908 -q. G' <>~.<.,. Florida Statutes. oD WE. ~ BUILDI~;:j,CI~L: P-uL ~ DATE: ~v --- -- -- - - -- - -- - EnergyGauge@ (Version: FLRCNA-200) I hereby certify that the plans and specifications covered by this calculation are in compliance with the Florida Energy Code. PREPARED BY: DATE: Francis J Vari 6- I s-...o~ I hereby certify that this buildin compliance with the Flor' OWNER/AGE DATE: --- Cap: 30.0 kBtu/hr SEER: 10.00, Unducted Cap: 30.0 kBtu/hr HSPF: 7.00 Cap: 40.0 gallons EF: 0,90 CF, . FORM 600A-97 SUMMER CALCULATIONS Residential Whole Building Performance Method A - Details ADDRESS: Lot: 1,0 , Sub: SOV, Plat: PB 1 PG 55, Zephyrhills, FI, 33543- PERMIT #: BASE AS-BUlL T GLASS TYPES .18 X Conditioned X BSPM = Points Overhang Floor Area Type/SC Omt Len Hgt Area X SPM X SOF = Points .18 1190.0 42.08 9013.0 Single, Clear SE 5.0 1.0 52.0 56.64 0.41 1197.9 Single, Clear SW 2.0 1.0 50.8 52.82 0.42 1132.5 Single, Clear NW 2.0 1.0 25.4 37.74 0.56 536.9 As-Built Total: 128.3 2867.3 WALL TYPES Area X BSPM = Points Type R-Value Area X SPM = Points Adajcent 328.5 0.7 229.9 Frame, Wood, Exterior 11.0 1234.5 1.90 2345.6 Exterior 1234.5 1.90 2345.6 Frame, Wood, Adjacent 11.0 328.5 0.70 229.9 Base Total: 1563.0 2575.5 As-Built Total: 1563.0 2575.5 DOOR TYPES Area X BSPM = Points Type Area X SPM = Points Adjacent 20.0 1.60 32.0 Exterior Insulated 20.0 4.80 96.0 Exterior 37.8 4.80 1812 Exterior Insulated 17.8 4.80 85.2 Adjacent Insulated 20.0 1.60 32.0 Base Total: 57.8 213.2 As-Built Total: 57.8 213.2 CEILING TYPES Area X BSPM = Points Type R-Value Area X SPM = Points Under Attic 1190.0 0.60 714.0 Under Attic 30.0 1190.0 0.60 714.0 Base Total: 1190.0 714.0 As-Built Total: 1190.0 714.0 FLOOR TYPES Area X BSPM = Points Type R-Value Area X SPM = Points Slab O.O(p) 0.0 0.0 Raised Concrete 4.0 1190.0 -1.70 -2023.0 Raised 1190.0 -3.43 -4081.7 Base Total: -4081.7 As-Built Total: -2023.0 INFILTRATION Area X BSPM = Points Area X SPM = Points 1190.0 14.31 17028.9 1190.0 14.31 17028.9 Summer Base Points: 25462.9 Summer As-Built Points: 21375.9 Total Summer X System = Cooling Total X Cap X Duct X System X Credit = Cooling Points Multiplier Points Component Ratio Multiplier Multiplier Multiplier Points 21375.9 1.000 1.000 0.341 0.950 6924.7 25462.9 0.3577 9108.1 21375.9 1.00 1.000 0.341 0.950 6924.7 EnergyGauge ™ DCA Form 600A.97 , FORM 600A-97 WINTER CALCULATIONS Residential Whole Building Performance Method A - Details ADDRESS: Lot: ,,() , Sub: SOV, Plat: PB 1 PG 55, Zephyrhills, FI, 33543- PERMIT #: BASE AS-BUlL T GLASS TYPES .18 X Conditioned X BWPM = Points Overhang Floor Area Type/SC Omt Len Hgt Area X WPM X WOF = Points .18 1190.0 4.79 1025.9 Single, Clear SE 5.0 1.0 52.0 8.34 1.94 840.8 Single, Clear SW 2.0 1.0 50,8 9.22 1.51 708.6 Single, Clear NW 2,0 1.0 25.4 12.23 0.99 307.6 As-Built Total: 128.3 1857.0 WALL TYPES Area X BWPM = Points Type R-Value Area X WPM = Points Adajcent 328.5 1.8 591.3 Frame, Wood, Exterior 11.0 1234.5 2,00 2469.0 Exterior 1234.5 2.00 2469.0 Frame, Wood, Adjacent 110 328.5 1.80 591.3 Base Total: 1563.0 3060.3 As-Built Total: 1563.0 3060.3 DOOR TYPES Area X BWPM = Points Type Area X WPM = Points Adjacent 20.0 4,00 80.0 Exterior Insulated 2'0.0 5.10 102.0 Exterior 37.8 5.10 192,5 Exterior Insulated 178 5.10 90.5 Adjacent Insulated 20.0 4.00 80.0 Base Total: 57.8 272.5 As-Built Total: 57.8 272.5 CEILING TYPES Area X BWPM = Points Type R-Value Area X WPM = Points Under Attic 1190.0 0.60 714.0 Under Attic 30.0 1190.0 0.60 714.0 Base Total: 1190.0 714.0 As-Built Total: 1190.0 714.0 FLOOR TYPES Area X BWPM = Points Type R-Value Area X WPM = Points Slab O.O(p) 0.0 0.0 Raised Concrete 4.0 1190.0 1.45 1725.5 Raised 1190.0 .0.20 -238.0 Base Total: -238.0 As-Built Total: 1725.5 INFIL TRATION Area X BWPM = Points Area X WPM = Points 1190.0 -028 -333.2 1190.0 -0.28 -333.2 Winter Base Points: 4501.5 Winter As-Built Points: 7296.1 Total Winter X System = Heating Total X Cap X Duct X System X Credit = Heating Points Multiplier Points Component Ratio Multiplier Multiplier Multiplier Points 7296.1 1.000 1.116 0.488 1.000 3969.8 4501.5 1.0730 4830.2 7296.1 1.00 1.116 0.488 1.000 3969.8 EnergyGauge™ DCA Form 600A-97 FORM 600A-97 WATER HEATING & CODE COMPLIANCE STATUS Residential Whole Building Performance Method A - Details ADDRESS: Lot:~, Sub: SOV, Plat: PB 1 PG 55, Zephyrhills, FI, 33543- PERMIT #: BASE AS-BUlL T WATER HEATING Number of X Multiplier = Total Tank EF Number of X Tank X Multiplier X Credit = Total Bedrooms Volume Bedrooms Ratio Multiplier 3 2564.00 7692.0 40.0 0.90 3 1.00 2507.02 1.00 7521.1 As-Built Total: 7521,1 CODE COMPLIANCE STATUS BASE AS-BUlL T Cooling + Heating + Hot Water = Total Cooling + Heating + Hot Water = Total Points Points Points Points Points Points Points Points 9108.1 4830.2 7692.0 21630.2 6924.7 3969.8 7521.1 18415.5 I PASS I EnergyGauge™ DCA Form 600A.97 , FORM 600A-97 Code Compliance Checklist Residential Whole Building Performance Method A - Details ADDRESS: Lot:~, Sub: SOV, Plat: PB 1 PG 55, Zephyrhills, FI, 33543- PERMIT #: 6A-21 INFILTRATION REDUCTION COMPLIANCE CHECKLIST COMPONENTS i SECTION Ext~ri~r~\^Ji!1~Q~ ~ Q.qQ.~~i061 ,AS-C. 1 .1 Exterior & Adjacent Walls I 606.1.ABC.12.1 I I i REQUIREIVIEtoJ!S FORJOACH PRACTICE It.J1axirT1lJ'!l.:,3_~tnllsqftwincJ.o''''~.El~~?_cfrT1/s_qft, door areao. _ .... _ _. . I Caulk, gasket, weatherstrip or seal between: windows/doors & frames, surrounding wall; ! foundation & wall sole or sill plate; joints between exterior wall panels at corners; utility penetrations; between wall panels & top/bottom plates; between walls and floor. I EXCEPTION: Frame walls where a continuous infiltration barrier is installed that extends : frQm..... and is sealed tO,thE! foundation to thel()p~~. 606.1ABC.122 I' Penetrations/openings >1/8" sealed unless backed by truss or joint members. EXCEPTION: Frame floors where a continuous infiltration barrier is installed that is sealed , to the..Q.erimeter, penetrations and seams. 606.1ABC.1.2.3 [B~t;een'~lIs & c;ilings; p~~et;~'tions of-~~i1;ng pla~e of top floor; around shafts, chases, Ii soffits, chimneys, cabinets sealed to continuous air barrier; gaps in gyp board & top plate; attic access. EXCEPTION: Frame ceilings where a continuous infiltration barrier is -- - - ..-----r-- - I !nstaJ!edJh~~seal~alJh.e~imeter,~tp_en~trations and s~a.OlS, --- Recessed Lighting Fixtures 606 1 ABC 1 24 T Type IC rated with no penetrations, sealed; or Type IC or non-IC rated, installed inside a _____ ___ -T _ ____I ~:~~~~Q.~~: :~:_~~~ec~~:;an~~ & 3" fro~in~ul:tion; o~ T~pe IC rated W~h < ~ 0 cfm from lIi1.ulti~story H()~_s~ ... __. . _ J 606. 1 ~1:!.<;L2o.? LAi!J)~r~r ()n pelirn~~!o.uloorgavJtl' QE:!tween 11()0r~ . Additional Infiltration reqts I 606.1.ABC.1.3 I Exhaust fans vented to outdoors, dampers; combustion space heaters comply with NFPA, J h~\Ie coml:>LJstion air. Floors Ceilings 6A~22 OTtfER PRESCRIPTIVE MEASURES (must be _met.c>r~xceed~db . all residences, COMPONENTS : SECTION REQUIREMENTS ~---~---. - ---------.-- - -- .-. i .._--'~-_..__...- ---- __n _ ---'-'-'--~---_._._- .. --___,_ __"._________.., _ _. ______ ____ ___________n__ ___.___._______ Water Heaters i 612.1 , Comply with efficiency requirements in Table 6-12. Switch or clearly marked circuit .u_.____. f u_ .-- -..- ..~- breaker ~Iect,.ic:) or cutoffigas) must b.~provlcf~g._~xterr1~1 ()r buill:-inheatt@p requirEld. Swimming Pools & Spas 1612.1 i Spas & heated pools must have covers (except solar heated). Non-commercial pools I must have a pump timer. Gas spa & pool heaters must have a minimum thermal I . efficiency of 78%. Shower heads r 612.1 i Waterfl~\V ~u-st be restricted to no more than 2,5 .lliIllons jJer minute at 80 PSIG. -----,.-----.. ---~-~-- --T------- T ,----~----- .. ----- .---------- --. -----.- --- ----- ____ _'_____.______ _ __ "________n_ ___ _ ._____... ~ ____ __ __" __ ___ ___ _ _ ,_ _n___. ___ Air Distribution Systems ! 610.1 ! All ducts, fittings, mechanical equipment and plenum chambers shall be mechanically i I attached, sealed, insulated, and installed in accordance with the criteria of Section 610. n.. --.-- j~- .__._ ... ___-+ Ducts jrl uncond!E()r1ed allic~:.B-6 mino_ir1sul?JioI1.:________~ u _.__ _HVA<::..Controls - _ EjQ7-1_. t~~arCl!E!r~diIY accessible manu~I()r...auto.IT1ati~Jherl11o~t~ for E:!<i.cb...3t.st~!ll..:._n.. Insulation : 604.1, 602.1 I Ceilings-Min. R-19. Common walls-Frame R-11 or CBS R.3 both sides. Common ceiling & floors R-11. EnergyGauge™ DCA Form 600A-97 EnergyGauge@/FlaRES'97 FLRCNA-200 i CHECK .-.r.--- -.. I ! ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE SCORE* = 85.3 The higher the score, the more efficient the home. Vari Construction Services, Lot:~, Sub: SOV, Plat: PB 1 PG 55, Zephyrhills, FI, 33543- t. New construction or existing 2. Single family or multi-family 3. Number of units, if multi-family 4. Number of Bedrooms 5. Is this a worst case? 6. Conditioned floor area (ft') 7. Glass area & type a. Clear - single pane b. Clear - double pane c. Tint/other SC/SHGC - single pane d. Tint/other SC/SHGC - double pane 8. Floor types a. Raised Concrete b. N/A c. N/A 9. Wall types a. Frame, Wood, Exterior b. Frame, Wood, Adjacent c. N/A d. N/A e. N/A 10. Ceiling types a. Under Attic b, N/A c. N/A II. Ducts a. Sup: Unc. Ret: Unc. AH: Attic b. N/A New Single family I 3 Yes 1190 ft' 128.3 ft' 0.0 ft' 0.0 ft' 0.0 ft' R=4.0, 1190.0ft' R=] 1.0, 1234.5 ft' R=] 1.0, 328.5 ft' R=30.0, 1190.0 ft' Sup. R=6.0, 225,0 ft 12. Cooling systems a. Central Unit Cap: 30.0 kBtu/hr SEER: 10.00, Unducted b. N/A c. N/A 13. Heating systems a. Electric Heat Pump Cap: 30.0 kBtu/hr HSPF: 7.00 b. N/A c. N/A 14. Hot water systems a. Electric Resistance Cap: 40.0 gallons EF: 0.90 b. N/A c. Conservation credits (HR-Heat recovery, Solar DHP-Dedicated heat pump) 15. HV AC credits (CF-Ceiling fan, CV-Cross ventilation, HF-Whole house fan, PT-Prograrnmable Thermostat, RB-Attic radiant barrier, MZ-C-Multizone cooling, MZ-H-Multizone heating) CF, ] certify that this home has complied with the Florida Energy Efficiency Code For Building Construction through the above energy saving features which will be installed (or exceeded) in this home before final i erwise, a new EPL Display Card will be completed based on installed Code es. Date: ~ - /j~ -dJ Adrnce" of Now Home, ~ () ~ L:.VO(..' CitylFL Zip, Zr>~rL 4 :FL <l- co" WI! .",,,.;\ 'NOTK Th, home', "'Ii;;;;~;gy Pt:i!L~o" " only ""ai/able through th, FLA/RES 'ompuler program This is not a Building Energy Rating. If your score is 80 or greater (or 86 for a us EP A/DOE EnergyStar7Mdesignation). your home may qualifY for energy efficiency mortgage (EEM) incentives if you obtain a Florida Energy Gauge Rating. Contact the Energy Gauge Hotline at 407/638-1492 or see the Energy Gauge web site at www.jSec.ucfedufor information and a list of certified Raters. For information about Florida's Energy Efficiency Code For Building Construction. contact the Department of Community Affairs at 850/487-1824. EnergyGauge@ (Version: FLRCNA-200) BUILDING INPUT SUMMARY REPORT Title: Arlington II Model Family Type: Single I- Owner: Vari Construction Services New/Existing: New U # of Units: Bedrooms: 3 W -, Builder Name: Vari Homes Conditioned Area: 1190 0 Climate: Central Total Stories: 1 0::: a.. Permit Office: (blank) Worst Case: Yes Jurisdiction #: (blank) Rotate Angle: (blank) (J) 1# a::: ~ u 011 o! -Ii LL.i (J) # C> Z -I W Floor Type Raised Concrete R-Val 4.0 Area/Perimeter Units 1190.0ft2 Ceiling Type Under Attic R-Val 30.0 Area Base Area Units 1190.0 ft2 1190.0 ft2 # Wall Type (J) 1 Frame - Wood -I 2 Frame - Wood -I ~ # Panes Tint 1 Single Clear 2 Single Clear 3 Single Clear Location R-Val Area Units Exterior 11.0 Adjacent 11.0 1234.5 ft2 328.5 ft2 Ornt Area OH Length N 13.0 ft2 5.0 ft E 25.4 ft2 2.0 ft S 25.4 ft2 2.0 ft OH Hght 10ft 1.0 ft 10ft (J) ~ o o z 3: u (J) :E Rater Name: Rater Certification #: Area Under Fluorescent: Area Under Incandescent: (blank) (blank) 0.0 0.0 Class #: 3 Duct Leakage Type: N/A Visible Duct Disconnects: N/A Leak Free Duct System Proposed: No HRV/ERV System Present?: o 0.00 hp Electric Electric l # System Type ~ 1 Electric Heat Pump ~ < W :I: IC~~ditM~ltiPIi~;;: None ~ L~_~~gf~ror1. ~g~~Wol1 u i 1 Uncond. Uncond. :JI 01 (J) 0::: o o o i# C> Z -I o o u Units 4 2 1 i # 0::: r- n Wi1 1-' <I ~I I # 0:::1 LL. W 0::: Address Type: Lot Information Lot#: "0 Subdivision: SOV Platbook: PB 1 PG 55 Street: N/A County: Pasco City, St, Zip: Zephyrhills, FI, 33543- Door Type Orientation Area Units Insulated Exterior 20.0 ft2 Insulated Exterior 17.8 ft2 Insulated Adjacent 20.0 ft2 System Type -- '" -.-- Central Unit, Unducted Efficiency SEER 10.00 Capacity 30.0 kBtu/hr Credit Multipliers: Ceil Fn Efficiency COP: 7.00 Capacity 30.0 kBtu/hr Air Handler Location Attic Supp'ly R-\7al 6.0 Supply L!n1!lh 225.0 ft System Type EF Electric Resistance 0.90 Cap. 40.0 Conservation Type None Con. EF 0.00 Use Default? Yes Annual Operating Cost Electric Rate N~ N~ Pool Size: Pump Size: Dryer Type: Stove Type: Avg Ceil Hgt: EnergyGauge@ (Version: FLRCNA-200) Summary Energy Code Results Residential Whole Building Performance Method A tol ~ 0 Vari Construction Services Project Title: Arlington II Model Class 3 Rating Registration No. 0 Climate: Central Zephyrhills, FI 33543- Building Loads Base As-Built Summer: 25463 points Summer: 21376 points Winter: 4502 points Winter: 7296 points Hot Water: 6769 points Hot Water: 6769 points Total: 36733 points Total: 35441 points 6/15/00 Energy Use Base As-Built Cooling: 9108 points Cooling: 6925 points Heating: 4830 points Heating: 3970 points Hot Water: 7692 points Hot Water: 7521 points Total: 21630 points Total: 18416 points PASS e-Ratio: 0.85 EnergyGauge@(Version: FLRCNA-200) FROM ALL-AMERICAN HOME-INSPECTORS PHONE NO, 813 853 2711 P02 /~ ARKAY ENGINEERING, structural INc. . engIneers August 2, 2000 VARI Construction Servi~A~, Tn~. 23110 State Road 54 - #106 Lutz, Florida 33549 Attention: Frank Vari Rc: Arlington Revised Hodel - Silver Oaks Villago - Lot #60 pormit #9611 - Arkay Engineering, Inc. Job # 3395 Dear Mr. Vari: This letter is to confirm our telephone conversation regarding a field revision to the above referenced project. The building shall be modified as follows: 1) The house will be widened from 44'-8" to 46'-8" on tho garago side (The garage width will increase from 201-6" to 22'-6" and the patio shall widen from 71-0" to 91-0"). 2) The extended structure shall be constructed per the "Typical Wall Soction" shown on shoot 2 of tho approved construction plans. 3) The foundation of the extended portion of the building shall be tied into the existing foundation with 2-#5 rebars drilled and set in epoxy with a minimum embedment of 6 inches into the side of the existing foundation. These modificCltioms tlL.~ ~tL-uctuL"tllly acceptable and conform to the 1997 Standard Building Code, Chapter 16, Section 1606 for 100 MPH wind loads. If you need Clny fUL.th~.r: assistance with this matter, please give me a call. Inc. P.E. Lakeland. Florida 33809 Fax: 863-816-2118