Loading...
HomeMy WebLinkAbout00-9888 --:~==---=---=-=.::_':: -:-:-:- _'::='"- BUILDING PERMIT CITY OF ZEPHYRHILLS (813) 788-6611 Permit 09888 Date 11/3/00 $637 BUILDING $88.48 ELECTRICAL $67.50 PLUMBING $40.00 MECHANICAL Sewer Conn Property Owner: Job Address: PPB Enterprises, Inc. 6546 North Lake DR. Water Meter: $1,278 $ 350 $ 180 Water Conn: Parcell.D. # 03-26-21-0150-00000-0260 Zoning: P. U. D. Energy Code: Radon Gas: Description of Work Single Family Residential e"tI~T "PO/...E F:P- )62 ~:l~-OV ~:/~jJlu... (L/~...dc. ~-:]) fJlllli"J.J.E" ~J)6~c0~~~~~~o~~f~frtl Complete Plans. Specifications and Fee Must Accompany Application. C.O. All work shall be performed in accordance with City Codes and Ordinances. T.I.F.'s: fit IPf'/; ,mn-$R /9/?2'fXL $24.84 w ""PV./"&: /'T~(jjJ1 'f: SO I tilT (0'-' ~ ) Valuation or Contract Price $81,560 Inspector City License Registration # State Certified License# 2018 Martin Elec 97 ELECTRICAL ~lJ) 1.8> -1'I'j~ Colby Jaynes 100 PLUMBING Burgess Const. 2018 BUILDING Ftr. v:;-.5"-00 5'1C. Pre SLB t Z .. / 9ft. Lintel , I biD' 5' ~ FRM.~ If --9- "t 5'1( Insul. CL WL 4-15- c>! ~ /C Driveway ('---/J/-O/?j( ~ Bahr's A/C 17 MECHANICAL T S SLB J G -Z2-cc> 6' R p, erv. Rough In i/"'".I./..p,./~ ( Sf? Tub Set ......--il.. c;L. a I >'R.. Meter Can Water Const. Pole 12~22.L.o[) .:srs.. Sewer5- J S-o I S~ Pool Final . s:.. IS.... ~ I :J f<. Pre-Meter Vh -~~-oi 5/L Final r~B~I?-5"-OOS~ Breakers Ducts Insl. 4".. 9- ~ I S/( comp/ssor Final '. 5- J.~-{)~ till2J.L~ REINSPECTION FEES: When extra inspection trips are necessary due to anyone of the following reasons, a charge of Fifteen and 00/100 Dollars ($ 25.00) shall be made for each trip for each trade: , ~ a. Wrong Address ~ -M. "7?~. ~ U.s b. Condemned work resulting from faulty construction. () c. Repairs or corrections not made when inspection called. d. Work not ready for inspection when called, e. Permit not posted on job site. f. Plans not at job site, g. Work not accessible. The payment of inspection fees shall be made before any further permits will be issued to the person owning same. ~~ - ! ~, ~ "~--r-Reecf.vcd' ~ ~'''''.'~'-'~ - . ---- '~---I ,."."....- .......'.'1 I I I '.'1 ~ate .... 7' )1' ,,_f, .~ t -----.----------------------------------------------------------------------------------------.---------------------------------------------------- It. ..... OFFICE CSE ONLY TRANSPORTATION REC. NO. , RESOURCE RECOVERY REC. NO.1) t) ~ . '-, DATE 1.11J j DATE ,J i ll./r f // fIT , BY BY f" / &:'/~ iL' '" GreeJ ,'I Bldgllnsp While Applicant Canary Trans/Finance Canary RR/Finance Pink Office leecal:ce PC93113094/D . I APPLICATION FOR PERMIT CITY OF ZEPRYRRILLS BUILDING DEPARTMENT 10 -/0- 0 () DATE RECEIVED PLANS REVIEW FEE p~p, ~~n\Y~~ i fo~ __tn_ (_~ , S,CP/f(fiJS LEGAL DESCRIPTION: LOT(S) ~ ~ BLOCK ~N SUBDIVISION S(L.V;{~ OAKs PARCEL ID # 03 ~J(Q-JJ-Q)150--:-o0000-0~loO {OBTAIN FROM PROPERTY TAX NOTICE} JOB ADDRESS PHONE~ 7~~-ICflf~ OWNER'S NAME WORK PROPSED: ~EW CONSTRUCTION D SIGN PROPOSED USE:~GL FAMILY DWELLING D COMMERCIAL D ADDITION DALTERATION D REPAIR D INSTALL D MOVE D DEMOLISH DMULTI-FAMILY D INDUSTRIAL D# OF UNITS D SWIMMING POOL D MOBILE HOME DOTHER D RESTAURANT & HEALTH DEPARTMENT APPROVAL DESCRIPTION OF WORK S r f\) '-l, t... S"\D4j ~&S\~~TI,qL SQUARE FOOTAGE ~ g' II HEIGHT -0 f BUILDING SIZE ~ It (g;l RESIDENTIAL: COMMERCIAL: ATTACH (2) PLOT PLANS & (2) SETS OF BUILDING PLANS & (1) SET ENERGY FORMS. ATTACH (3) SETS OF BUILDING PLANS & (1) SET ENERGY FORMS. PROPERTY SURVEY REQUIRED FOR ALL NEW CONSTRUCTION. PERMITS REQUESTED D BUILDING $ q9t 3~p ;Joo VALUATION OF TOTAL CONSTRUCTION D ELECTRICAL AMP SERVICE ~ FLORIDA POWER D W.R.E.C. D PLUMBING D MECHANICAL $ ~5op VALUATION OF MECHANCIAL INSTALLATION D GAS D ROOFING D SPECIALTY D OTHER TYPE OF CONSTRUCTION: p{ BLOCK D FRAME D STEEL D OTHER FINISHED FLOOR ELEVATIONS IS PROJECT IN FLOOD ZONE AREAD YES i?J NO ........................ ,-, ,.,.:.:.:.;-:.,.:.,-,.,.,...:.:.:.",,,,~. ':;:r;:i:i:i:i:i:i:,:i:l:i:i:i:i;;:j:;:i:l;l.f. ........t!:i:!:U:~j:l:!:U:t!: . . . .' ~:i:~:FI~*i:!:i=!:!:!:j~:j~~. SIGNATURE COMPANy_BIJRr~~~ t.f:Y..)~"'\h\( :\\OA) STATE CERT OR REGIST pOo54 3<1). CITY PROCESSING # 8\. 0\ f BUILDER ************************************************ ELECTRICIAN ~ ()/ COMPANY ;JZ,/'M ~~, -h-,"<-..;&:;,c... y " STATE CERT OR REGIST # I;;.f<D 0 ( 3~"I1 SIGNATURE ~ -- I CITY PROCESSING # 77 PLOHBER 'w STATE CERT ORI REGIST #, ~ f Ok~ 'i SIGNATURE ~~~~ CITY PROCESSING # /6,Z SIGNATURE *****************************************************~*********** ~ . COMPANY ~A J-J /2:..s .r /2 () /DAN L. GAS f J 1- "..1'A! (...; ~"tf / STATE CERT OR REGI ST #' ~ t!.CO ,,3" fA .. . '"""" .. --^------ CITY PROCESSING # / 7 . ***************************************************************** MECHANICAL OTHER COMPANY STATE CERT OR REGIST # CITY PROCESSING # SIGNATURE ***************************************************************** CONDITIONS OF PERMIT AFFIDAVIT A. NOTICE OF DEED RESTRICTIONS The unde~slgned understands that this permit may be subject to ~deed restrictions" which ' may be more restrictive than City regulations. The undersigned assumes responsibility for compliance with any applicable deed restrictions. B. UNLICENSED CONTRACTORS AND CONTRACTOR RESPONSIBILITIES If the owner has hired a contractor or contractors to undertake work, they may be required to be licensed in accordance with state and local regulations. If the contractor is not licensed as required by law, both the owner and contractor may be cited for a misdemeanor violation under state law. If the owner or intended contractor are uncertain as to what licensing requirements may apply for the intended work, they are advised to contact the City of Zephyrhills Building Department, 813-788-6611. Furthermore, if the owner has hired a contractor or contractors, he is advised to have the contractor(s) sign portions of the ~Contractor Sections" of this application for which they will be responsible. If you, as the owner signs as the contractor, you are indicating that you, rather than the contractor, are responsible for the work. If the contractor wishes you to sign as contractor that may be an indication that he is not properly licensed and is not entitled to permitting privileges in the City of Zephyrhills. C. TRANSPORTATION IMPACT FEES AND UTILITY CONNECTION FEES D. CONSTRUCTUION LIEN LAW (CHAPTER 713, FLORIDA STATUTES, AS AMENDED) I certify that I, the applicant, have been provided with a copy of ~Florida's Construction lien Law - Homeowner's Protection Guide" prepared by the Florida Department of Agriculture and Consumer Affairs. If the applicant is someone other that the ~owner", I cerify that I have obtained a copy of the above described document and promise in good faith to deliver it to the ~owner" prior to commencement. E. CONTRACTOR' S/OWNER' S AFFIDAVIT I certify that all the information in this application is accurate and that all work will be done in compliance with all applicable laws regulating construction, zoning, and land development. Application is hereby made to obtain a permit to do work and installation as indicated. I certify that no work or installation has commenced prior to issuance of a permit and that all work will be performed to meet standards of all laws regulating construction, City codes, zoning regulations, and land development regulations in the jurisdiction. I also certify that I understand that the regulations of other governmental agencies may apply to the intended work, and that it is my responsibility to identify what actions I must take to be in compliance. Such agencies include but are not limited to: *Department of Environmental Regulation-Cypress Bayheads, Wetland Areas and Environmentally Sensitive Lands, Water/Wastewater Treatment *Southwest Florida Water Management District-Wells, Cypress Bayheads, Wetland Areas, Altering Watercourses *Army Corps of Engineers-Seawalls, Docks, Navigable Waterways *Department of Health & Rehabilitative Services, Environmental Health Unit-Wells, Wastewater Treatment, Septic Tanks *U.S. Environmental Protection Agency-Asbestos abatement I also certify that, if fill material is to be used in Flood Zone ~A" or ~A,etc.", it is understood that a drainage plan addressing a ~compensating volume" will be submitted which is prepared by a professional engineer registered in the State of Florida prior to permit issuance. A permit issued shall be construed to be a license to proceed with the work and not as authority to violate, cancel, alter, or set aside any provisions of the technical codes, nor shall issuance of a permit prevent the Building Official from thereafter requiring a correction of errors in plans, construction, or violations of any code. Every permit issued shall become invalid unless the work authorized by such permit is commenced within six months of issuance, or if work authorized by the permit is suspended or abandoned for a period of six months after the time the work is commenced. One 90 day extension of time may be allowed for the permit with fee charge of $15.00. The extension shall be requested in writing to the Building Official. An approved inspection must be logged during each six month period, or the project will be considered abandoned. WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUJ\ I..j!:NDER OR AN.ATTQRNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. JOBS UNDER $2,500 IN VALUE DO NOT NEED TO RECORD AND POST A ~NOTICE OF COMMENCEMENT". . ~ ppn? . / )/ \ / ,I) . · t) vl'J'(tR.PR.ISL\ / t)vNiJyIlvv,~.'lll ,l SIGNATURE: OWNj:R OR AGENT Ii / STATE OF FLORIDtO COUNTY OF ./ n. "Jt!.. ') The foregoing instrument was acknowledged :;fO~p;:,;}1? ~ ~~~f -:;~~t7~~ . (name of person aCk~~edged)) ~WhO is personally known to me, or ! r.. ,1.1 .--) g\f6t55 (Ml\'RJ(\I~N.' fV~{/1IA. bk~iv SIGNATURE: CONTRACTOR iI. i/ STATE OF FLORIDA ~ COUNTY OF ~YtZ_--)t*-d The foregoing instrument was acknowledged Befor m his 7i?day of ~ by ~ ~o d If person acknowledg' ) known to me, or o who has produced (type of identification) ~~.. . .WhO ~id ~di~. 0 ta2~ a~ 0:;- f r JJL LJ.R~~tI . . ._- e of person taking acknowledgement o who has produced i~(type of identification) a~.~. .~ Ddid. y:; not ta..ke an oath .':;7J~-, . ~-4f $,( Signature of person taking acknowledgment ~ ,Iv/ Name -. If printfetltu<D\F22;s~ped "'?f,ii~lt~~""~ BONDED THRU TROY FAIN \NSI;~AHC:, iNC PARCEL 1.D, SITF. (,I.AN (RESIDENTIAL USE ONLY) 3 SEC ;),1 RNG ;)6 TWP nATE: 9-10-00 OISo SUBD o;ttaO LOT 00000 BLOCK All drawings shall be drawn to scale or fully dimensioned for all parcels. .r ,2 () .;0 --\ :r- \ y --r. '" 8"-Cf" /. '\ 00 7; , -0" t_ 1"'-' I ,- o I - N ()~ " >c, \' o ,I "- \9 \ ~I,~r\ t 103'-0" III::: 2 0 I SHOW ALL EXISTING AND PROPOSED STRUCTURES GIVING DIMENSIONS AND SETBACKS. ALSO. INDICATE ANY BODIES OF WATER. TREES (INCLUDING SIZE, DIAMETER, TYPE), AND ROADWAYS (INCLUDING NAMES) ADJACENT TO THE PROPERTY. INDICATE TIlE SIZE, YEAR. AND NAME OF MOBILE; SUCH AS 12' X 60'. 1981. FLEETWOOD. ALL "EASEMENTS". "PROPERTY LINES". "RIGIIT-OF-WAY". and "JURISDICTIONAL LINES" must be shown on all site plans. DO NOT ENCROACH INTO ANY EASEMENT WITH A STRUCTURE. '" ~ 4 Ie o 4 o It NoelLE HONE SET-'UP rear (1150' ) - ao' - b - '8 II) a II) ... ... . . Eaietin. . ,. ,. ,. '. '. .,..41 'i 50' "OAO NANE /tOAD NA NE - - - 0 ~ 0 . ~ .'! . .; ROAD ..ANIE PL = PROPERTY LINE R/W = RIGII'f-OF-WAY o = TREES APPROVKD SITE PLAN MUST BE POSTED AT JOB LOCATI(It. NOTICE 01' DKIID RKSTllICrIat THIS PKRKIT ..y be subject to ''Deed Reatrictiona" wbicb are ~re reatrictive thmJ County regulations. Tbe peDlit holder ..~ reapon.ibility for c~l1ancea with any applicable deed reatrictiona. site05:ce PC95035005/A BURGESS CONST. 6546 NORTH LAKE DR. SQ. FEET PRICE MAIN OR LIVING AREA 1,772 $ 40.00 OTHER AREA UNDER ROOF 712 $ 15.00 OTHER VALUATION $ 81,560.00 FEE SHEET $ 398.00 ADDRESS $ 20.00 DRIVEWAY $ 20.00 BUILDING: $ 637.00 CREDIT: $ - BUILDING LESS CREDIT: $ 637.00 ELECTRICAL: $ 88.48 PLUMBING: $ 67.50 MECHANICAL: $ 40.00 RADON: $ 24.84 TOTAL $ 857.82 SEWER: $ 1,278.00 WATER: $ 350.00 IRRIGATION: $ - TOTAL: $ 1,628.00 WATER METER: $ 180.00 IRRIGATION METER $ I I I SUB-TOTAL $ 2,665.82 I TIF'S'r 99% $ 1% $ : I TOTAL: $ 2,665.82 f Department of Community Affairs FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION FORM 600A-93 Residential Whole Building Performance Method A PROJECT NAME: BUILDER :13uf!.GE~~ eVJ,Jj"f. AND ADDRESS: ~r4t.. AltJeTII~/I~@,.e. PERMITTIN~IT'I of CLIMATE /' OFFICE:Z~?H~RH~L5 ZONE: 41~ 51_1 61_1 OWNER:'P?'j.?, ENiCI!PRI5E5,71(1(! . PERMIT NO. t'>>qr;/!5 JURISDICTION NO. ('1160u 70 CK 1. New Construction attached 2. Single-Family 3. 0 case (yes/no) 4. 5. 1772.00 6. 2.00 7. 8.00 Single Pane 8a. O.Osqft 8b.188.8sqft 1. New construction or addition 2. Single family detached or Multifamily 3. If MUltifamily-No. of units 4. If Multifamily, is this a worst 5. Conditioned floor area (sq.ft.) 6. Predominant eave overhang (ft.) 7. Porch overhang length (ft.) 8. Glass area and type: a. Clear Glass b. Tint, film or solar screen 9. Floor type and insulation: a. Slab on grade (R-value, perimeter) 10.Net Wall type area and insulation: a. Exterior: 1. Concrete (Insulation R-value) b. Adjacent: 2. Wood frame (Insulation R-value) 11.Ceiling type area and insulation: a. Under attic (Insulation R-value) 12.Air distribution systems a. Ducts (Insulation + Location) 13.Cooling system 14.Heating System: 15.Hot water system: 16.Hot Water Credits: (HR-Heat Recovery, DHP-Dedicated Heat Pump) 17.Infiltration practice: 1, 2 or 3 18.HVAC Credits (CF-Ceiling Fan, CV-Cross vent, HF-Whole house fan, RB-Attic radiant barrier, MZ-Multizone) 19.EPI (must not exceed 100 points) a. Total As-Built points b. Total Base points SN: 8132 CENTRAL Double Pane O.OOsqft O.OOsqft 9a.R= 0.00 , 201.20 ft 10a-1 R= 5.00, 1108.90sqft____ 10b-2 R=11.00, 272.00sqft____ 11a.R=22.00 , 1772.00sqft____ 12a. R= 6.00, uncond 13. Type: Central A/C SEER: 11.05 14. Type: Heat Pump HSPF: 7 . 40 15. Type: Electric EF: 0.88 16. 17. 18. 2 CF CV 19. 19a. 19b. 76.38 26116.56 34192.85 ------------~------------------------------------------------------------------ ------------------------------------------------------------------------------- I Hereby certify that the plans and specifications covered by this calcu- lation are in complian e with the Florida Energy C~. . 1 PREPARE Y : 'KL_.. DATE: II Cre Review of the plans and specifications covered by this calculation indicates compliance with the Florida Energy Code. Before construction is completed this building will be inspected for compliance in accordance with Section 553.908 F.S. I hereby certify in compliance wi Code. OWNER/AGENT:~ DATE: that this building is the Florida Energy ~ g Q BUILDING FF~IAL: ~ 1J~_ DATE: LIJ . L--c...... I . ******************************************************************************* SUMMER CALCULATIONS ******************************************************************************* === BASE === === AS-BUILT === g~~i~--~;;~-~-~;~;-:- POINTS I ------------------------------------------------------------------------------- ------------------------------------------------------------------------------- TYPE SC ORIEN AREA x SPM X SOF = POINTS ------------------------------------------------------------------------------- E 100.80 82.2 8285.8 SGL TINT E 14.2 107.1 .71 1075.6 SGL TINT E 16.2 107.1 .41 714.2 SGL TINT E 16.2 107.1 .41 714.2 SGL TINT E 40.0 107.1 .52 2227.7 SGL TINT E 14.2 107.1 .71 1075.6 W 88.00 82.2 7233.6 SGL TINT W 16.2 107.1 .82 1420.8 SGL TINT W 16.2 107.1 .82 1420.8 SGL TINT W 16.2 107.1 .82 1420.8 SGL TINT W 16.2 107.1 .82 1420.8 SGL TINT W 23.2 107.1 .82 2034.7 ------------------------------------------------------------------------------- .15 X CONDo FLOOR / TOTAL GLASS = ADJ. X GLASS = AREA AREA FACTOR POINTS ADJ GLASS POINTS GLASS POINTS ------------------------------------------------------------------------------- .15 1,772.00 188.80 1.408 15,519.36 21,848.76 I 13,525.31 =============================================================================== NON GLASS------------ I AREA X BSPM = POINTS TYPE R-VALUE AREA X SPM = POINTS ------------------------------------------------------------------------------- WALLS---------------- Ext 1108.9 1.0 1108.9 Ext NormWtBlock In 5.0 1108.9 1.00 1108.9 Adj 272.0 .7 190.4 Adj Wood Frame 11.0 272.0 .70 190.4 DOORS---------------- Ext 20.0 4.8 96.0 Ext Insulated 20.0 4.80 96.0 Adj 20.0 1.6 32.0 Adj Wood 20.0 2.40 48.0 CEILINGS------------- UA 1772.0 .6 1063.2 Under Attic 22.0 1772.0 .90 1594.8 FLOORS--------------- SIb 201.2 -31. 8 -6398.2 Slab-on-Grade .0 201.2 -31.90 -6418.3 INFILTRATION--------- 1772.0 10.9 19314.8 Practice #2 1772.0 10.90 19314.8 TOTAL SUMMER POINTS I 37,255.90 ------------------------------------------------------------------------------- ------------------------------------------------------------------------------- TOTAL X SUM PTS =============================================================================== 29,459.93 SYSTEM = MULT COOLING I TOTAL POINTS COMPON X CAP X DUCT X SYSTEM X CREDIT = COOLING RATIO MULT MULT MULT POINTS ------------------------------------------------------------------------------- 37,255.90 .37 13,784.68 I 29,459.93 1.00 1.100 .309 .860 8,611.55 =============================================================================== ******************************************************************************* WINTER CALCULATIONS ******************************************************************************* === BASE === === AS-BUILT === g~~i~--~;~-~-~;;;-:- POINTS I ------------------------------------------------------------------------------- ------------------------------------------------------------------------------- TYPE SC ORIEN AREA x WPM X WOF = POINTS ------------------------------------------------------------------------------- E 100.80 -3.4 -342.7 SGL TINT E 14.2 -2.0 -.61 17.3 SGL TINT E 16.2 -2.0 -3.11 100.7 SGL TINT E 16.2 -2.0 -3.11 100.7 SGL TINT E 40.0 -2.0 -2.03 162.4 SGL TINT E 14.2 -2.0 -.61 17.3 W 88.00 -3.4 -299.2 SGL TINT W 16.2 -2.0 .02 -.5 SGL TINT W 16.2 -2.0 .02 -.5 SGL TINT W 16.2 -2.0 .02 -.5 SGL TINT W 16.2 -2.0 .02 -.5 SGL TINT W 23.2 -2.0 .02 -.8 ------------------------------------------------------------------------------- .15 X CONDo FLOOR / TOTAL GLASS = ADJ. X GLASS = AREA AREA FACTOR POINTS ADJ GLASS POINTS GLASS POINTS ------------------------------------------------------------------------------- .15 1,772.00 188.80 1.408 -641.92 -903.72 I 395.41 ------------------------------------------------------------------------------- ------------------------------------------------------------------------------- NON GLASS------------ I AREA X BWPM = POINTS TYPE R-VALUE AREA X WPM = POINTS ------------------------------------------------------------------------------- WALLS---------------- Ext 1108.9 1.1 1219.8 Ext NormWtBlock In 5.0 1108.9 2.90 3215.8 Adj 272.0 1.8 489.6 Adj Wood Frame 11.0 272.0 1.80 489.6 DOORS---------------- Ext 20.0 5.1 102.0 Ext Insulated 20.0 5.10 102.0 Adj 20.0 4.0 80.0 Adj Wood 20.0 5.90 118.0 CEILINGS------------- UA 1772.0 .6 1063.2 Under Attic 22.0 1772.0 .90 1594.8 FLOORS--------------- SIb 201.2 -1.9 -382.3 Slab-on-Grade .0 201.2 2.50 503.0 INFILTRATION--------- 1772.0 4.1 7265.2 Practice #2 1772.0 4.10 7265.2 TOTAL WINTER POINTS I 8,933.79 ============~================================================================== TOTAL X WIN PTS ============================~================================================== 13,683.82 SYSTEM = MULT HEATING I TOTAL POINTS COMPON X CAP X DUCT X SYSTEM X CREDIT = HEATING RATIO MULT MULT MULT POINTS ------------------------------------------------------------------------------- 8,933.79 1.10 9,827.17 I 13,683.82 1.00 1.100 .460 1.000 6,924.01 =============================================================================== ******************************************************************************* WATER HEATING ******************************************************************************* === BASE === === AS-BUILT === =============================================================================== NUM OF BEDRMS x MULT TOTAL I TANK VOLUME EF TANK RATIO x MULT x CREDIT MULT = TOTAL ------------------------------------------------------------------------------- 3 3527.0 10,581. 00 I 40 .88 1.000 3527.0 1.00 10,581.00 ------------------------------------------------------------------------------- ------------------------------------------------------------------------------- ******************************************************************************* SUMMARY ******************************************************************************* === BASE === === AS-BUILT === COOLING POINTS + ------------------------------------------------------------------------------- ------------------------------------------------------------------------------- HEATING POINTS HOT WATER + POINTS = TOTAL I COOLING POINTS POINTS + HEATING POINTS HOT WATER + POINTS = TOTAL POINTS ------------------------------------------------------------------------------- 13784.7 9827.2 10581.0 34,192.85 I 8611.6 6924.0 10581.0 26,116.56 ------------------------------------------------------------------------------- ------------------------------------------------------------------------------- ***************** * EPI = 76.38 * ***************** '. ;. For detailed information of the EPI rating number or for any ITEM listed, ask your Builder for DCA Form 600A-93 or Form 600B-93 ENERGY GUIDE EPI= 76.4 o 10 20 30 40 50 60 70 80 90 100 I------------------------------x----------I The maximum allowable EPI is 100. The lower the EPI the more efficient the home RESIDENTIAL ENERGY PERFORMANCE RATING SHEET ITEM HOME VALUE Low Efficiency High Efficiency WINDOWS..................... Single Tint SINGL CLR DBL TINT I------x--------------I INSULATION. . . . . . . . . . . . . . . . . . Ceiling R-Value......... 22.0 R-10 R-30 I------------x--------I R-O R-7 I--------------x------I R-O R-19 Ix--------------------I Wall R-Value......... 5.0 Floor R-Value......... 0.0 AIR CONDITIONER............. SEER. . . . . . . . . . . . . . . . . . . . .. 11. 1 10.0 SEER 17.0 I---x-----------------I HEATING SySTEM.............. Electric HSPF............ 7.4 6.8 HSPF 12.0 I--x------------------I WATER HEATER................ Electric EF.............. 0.88 0.88 0.96 Ix--------------------I 0.54 0.90 1---------------------1 0.40 0.80 1---------------------1 Gas EF.............. 0.00 Solar EF.............. OTHER FEATURES.............. . .... ......... ...... ........ I certify that these energy saving features required for the Florida Energy Code have been installed in this house. Address: Builder Signature: Date: City/Zip Florida Energy Code for Building Construction - 1993 Florida Department of Community Affairs FL-EPL CARD93 986758 , *== o PERFORMANCE BUSINESS PROOUCTS.INC. 813-71l1-6OO8 FAX 813-719-7919 CITY OF ZEPHYRHILLS ZEPHYRHILLS, FLORIDA (lCJ . ?;Z ?CJ WATER ACCT. NO. DATE Ii - ~ -0 () ~~.65 (] Bn!7"OuJe:r.(k.- &nt'riU~ OWNERI 2- g r-; J - - RENTER . , ....Af (LA i::lA I~. ~.. / ' ~/?~b /?fYl~jlHl- G. _Z~~';;~~i n :3.1p(i) SERVICE ADDRESS %'~-L/~ 7?~~ ri)/J. J..nT~ ~ MAILING SHUT OFF SERVICE o ~ ~- o SEWER TURN ON SERVICE INSTALl METER o GARBAGE READ METER o o o ~. CHECK METER o OUT CITY L No. OF UNllS OTHER _ DEPOSIT AMOUNT _ AMOUNT LAST BILL -+-/1 ~~W _ DATE _ MISC. CHARGE 'MJRK COMPLETED BY & DATE COMPLETED ORDER TAKEN BY Retain white form in office at all times. Send pink & yellow forms to Water Service Dept Water Service [)apt to sign yellow fo.-m & return to office.