HomeMy WebLinkAbout00-0003
BUILDING PERMIT
CITY OF ZEPHYRHILLS
(813) 788-6611
Permit
00003
1'1. - ~o --1) 2J
.,,--
Date
BUILDING
ELECTRICAL
PLUMBING
~D
MECHANICAL
Sewer Conn
Water Conn:
Property Owner:
Job Address:
Parcel 1.0. #
~;J fr~~~~,
Water Meter:
T,I.F.'s:
Zoning:
DescriPtion of Work
Energy Code: Radon Gas: -z:; /} -",vt'?.
~ ~.d. 6f r~{~ _uj K>i1.J!.~ ..!2lJ~
FINAL J- /9-~ I
DATE
NO OCCUPANCY BEFORE C.O.
Complete Plans, Specifications and Fee Must Accompany Application.
All work shall be performed in accordance with City Codes and Ordinances.
c.o.
BUILDING
ELECTRICAL
DATE
Inspector ~
:~;~;. e r) ~O'--
.' \f~,- ~
Company
Address
c:ePho;,e~
..,.-at Wlj~/ l1-~
~(~.
PLUMBING . MECHANICAL
Valuation or
Contract Price
iJ.Jd
~ '70tJ.
c:< '75 I
City License Registration #
State Certified License#
Ftr.
Pre SLB
Lintel
FRM.
Insul. CL
WL
Tp. Servo
Rough In
Meter Can
Const. Pole
Pool
Pre-Meter
Final
SLB
Tub Set
Water
Sewer
Final
Breakers
Ducts Insl.
Compressor
Final
Driveway
REINSPECTION FEES: When extra inspection trips are necessary due to anyone of the following reasons, a
charge of Fifteen and 00/100 Dollars ($ 25.00) shall be made for each trip for each trade:
a. Wrong Address
b. Condemned work resulting from faulty construction.
c. Repairs or corrections not made when inspection called.
d. Work not ready for inspection when called.
e. Permit not posted on job site.
f. Plans not at job site.
g. Work not accessible.
The payment of inspection fees shall be made before any further permits will be issued to the person owning
same.
APPLICATION FOR PE1WI
CITY OF ZEPHYRHILLS
BUILDING DEPAR
/~ -/:2-0 U
JOB ADDRESS
CV/ JJA1 fI fu ~d ~
.7~V 6/1// g~A
PHONE
OWNER'S NAME
LEGAL DESCRIPTION: LOT(S)
BLOCK
SUBDIVISION
PARCEL ID #
(OBTAIN FROM PROPERTY TAX NOTICE)
WORK PROPSED: DNEW CONSTRUCTION
o ADDITION
DALTERATION
o REPAIR
o INSTALL
o SIGN
o MOVE
o DEMOLISH
PROPOSED USE: []SGL FAMILY DWELLING
~~OMMERCIAL
CJ RESTAURANT & HEALTH DEPARTMENT ,PPROVAL
kr _r:jJ'pJt5S/o,v //C../ K-h*frJ
[]MULTI-FAMILY
[] INDUSTRIAL
[]# OF UNITS
[] SWIMMING POOL
[] MOBILE HOME
o OTHER
DESCRIPTION OF WORK
;Ie> LJ
BUILDING SIZE
SQUARE FOOTAGE
HEIGHT
RESIDENTIAL: ATTACH (2) PLOT PLANS & (2) SETS OF BUILDING PLANS & (1) SET EN~~'FORMS.
COMMERCIAL: ATTACH (3) SETS OF BUILDING PLANS & (1) SET ENERGY FORMS. ~:5D .
/, 0: Q r;: 0 O:!I-ROPERTY SURVEY REQUIRED FOR ALL NEW CONSTRUCTION 0 i 1).:::;' f:1) ow'
/2A-"' ~ 00 ~Ml1/)/
. ~ ~~:,ERMITS REQUESTED 'ffP"
o BUILDING VALUATION OF TOTAL CONSTRUCTION
/
/
--------.
TYPE OF CONSTRUCTION: 0 BLOCK
o FRAME
o rtROEOC(1Jl-'
: N jLuO----
VALUATION OF MECHANCIAL INSTALLATtON / _ ~1:::1
o OTHER (j ( :9 '3 "} d
/\ -----....
IS PROJECT IN FLOOD ZON~~ 0 NO
I
o
FLORIDA POWER
o ELECTRICAL
AMP SERVICE
o PLUMBING
o MECHANICAL $
o GAS
o ROOFING
o SPECIALTY
o STEEL
o OTHER
FINISHED FLOOR ELEVATIONS
BUILDER
SIGNATURE
COMPANY
STATE CERT OR REGIST #
CITY PROCESSING #
********************************************************.k**** ****
ELECTlUCIAN
SIGNATURE
COMPANY
STATE CERT OR REGIST #
CITY PROCESSING #
********************************************************,k*** *****
PLUMBER
SIGNATURE
COMPANY
STATE CERT OR REGIST #
CITY PROCESSING #
**********~************************************************ ******
MECHANICAL
SIGNATURE
COMPANY
STATE CERT OR REGIST #
CITY PROCESSING #
********************************************************** ******
SIGNATURE
~ ~ COMPANYa/hme4C/"'J/ h-<tE &0 G
J::. STATE CERT OR REGIST # 39l/h3") 0002 & &
t. . CITY PROCESSING # #' ~ ') S / ,/
***************************************************************~
OTHER
CONDITIONS OF PERMIT AFFIDAVIT
A. NOTICE OF DEED RESTRICTIONS
The undersigned understands that this permit may be subject to "deed restrictions" which
may be mo~e restrictive than City regulations. The undersigned assumes responsibility for
compliance with any applicable deed restrictions.
B. UNLICENSED CONTRACTORS AND CONTRACTOR RESPONSIBILITIES
If the owner has hired a contractor or contractors to undertake work, they may be required
to be licensed in accordance with state and local regulations. If the contractor is not
licensed as required by law, both the owner and contractor may be cited for a misdemeanor
violation under state law. If the owner or intended contractor are uncertain as to what
licensing requirements may apply for the intended work, they are advised to contact the
City of Zephyrhills Building Department, 813-788-6611.
Furthe~ore, if the owner has hired a contractor or contractors, he is advised to have the
contractor(s) sign portions of the "Contractor Sections" of this application for which they
will be responsible. If you, as the owner signs as the contractor, you are indicating that
you, rather than the contractor, are responsible for the work. If the contractor wishes
you to sign as contractor that may be an indication that he is not properly licensed and is
not entitled to permitting privileges in the City of Zephyrhills.
C. TRANSPORTATION IMPACT FEES AND UTILITY CONNECTION FEES
D. CONSTRUCTUION LIEN LAW (CHAPTER 713, FLORIDA STATUTES, AS AMENDED)
I certify that I, the applicant, have been provided with a copy of "Florida's Construction
lien Law - Homeowner's Protection Guide" prepared by the Florida Department of Agriculture
and Consumer Affairs. If the applicant is someone other that the "owner", I cerify that I
have obtained a copy of the above described document and promise in good faith to deliver
it to the "owner" prior to commencement.
E. CONTRACTOR'S/OWNER'S AFFIDAVIT
I certify that all the info~ation in this application is accurate and that all work will
be done in compliance with all applicable laws regulating construction, zoning, and land
development.
Application is hereby made to obtain a permit to do work and installation as indicated. I
certify that no work or installation has commenced prior to issuance of a permit and that
all work will be perfo~ed to meet standards of all laws regulating construction, City
codes, zoning regulations, and land development regulations in the jurisdiction. I also
certify that I understand that the regulations of other governmental agencies may apply to
the intended work, and that it is my responsibility to identify what actions I must take to
be in compliance. Such agencies include but are not limited to: *Department of
Environmental Regulation-Cypress Bayheads, Wetland Areas and Environmentally Sensitive
Lands, Water/Wastewater Treatment
*Southwest Florida Water Management District-Wells, Cypress Bayheads, Wetland Areas,
Altering Watercourses
*A~y Corps of Engineers-Seawalls, Docks, Navigable Waterways
*Department of Health & Rehabilitative Services, Environmental Health Unit-Wells,
Wastewater Treatment, Septic Tanks
*U.S. Environmental Protection Agency-Asbestos abatement
I also certify that, if fill material is to be used in Flood Zone "A" or "A, etc.", it is
understood that a drainage plan addressing a "compensating volume" will be submitted which
is prepared by a professional engineer registered in the State of Florida prior to permit
issuance.
A permit issued shall be construed to be a license to proceed with the work and not as
authority to violate, cancel, alter, or set aside any provisions of the technical codes,
nor shall issuance of a permit prevent the Building Official from thereafter requiring a
correction of errors in plans, construction, or violations of any code. Every permit
issued shall become invalid unless the work authorized by such permit is commenced within
six months of issuance, or if work authorized by the permit is suspended or abandoned for a
period of six months after the time the work is commenced. One 90 day extension of time
may be allowed for the permit with fee charge of $15.00. The extension shall be requested
in writing to the Building Official. An approved inspection must be logged during each six
month period, or the project will be considered abandoned.
WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR
PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU. INTEND TO OBT~IN FINANCING, CONSULT
WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENC ENT. JOBS UNDER
$2,500 IN VALUE DO NOT NEED TO RECORD AND POST A "NOTIC COMMENCEME".
" 7
/
SIGNATURE: CONTRACTOR
~~~~yO~FFLORIDA (~~~A?
The foregoing instrument wa~ a crowl edged
Before is /~~<;ia of , ~OO
by
,~ (name of person acknowledged)
'~ho is personally known to me, or
SIGNATURE:
OWNER OR AGENT
STATE OF FLORIDA
COUNTY OF
The foregoing instrument was
Before me this_ day of
by
acknowledged
19_
(name of person acknowledged)
Owho is personally known to me, or
o who has produced
(type
and whoO did Odid not
o who has
of identification)
take an oath.
a
Signature of person taking acknowledgement
Signature of person taking acknowledgmeht
Name typed, printed or stamped
Name typed, printed or stamped
.'
.. .
Commercial Fire Eq~ipment Co.
FIRE & SAFETY EQUIPMENT
P. q. BOX 2442. BRANDON, FLORIDA 33509.2442
PHONE: 654.3357
PYRO CHEM, INe.
PCL-240/350/550
RESTAURANT KITCHEN
FIRE SUPPRESSION SYSTEM
TECHNICAL MANUAL
, ..... '.'-',
\ 7EPHYRHIL'LS (
, \ nEE DEP,'>.RTMENT / "C~OMPONENTS
,.....L~> i .......)
t " ..'
j .. __:_'~'~~~.__........ .... _'_"_ r:.J.r.~:.:=._ ___~ESIGN
l....ll(t.dJ!1e<.;r~F'PlJ S~~4,r _.____._ t
r-.JI~g~-'f..1:L_1-]11 ..-------INlSTALLATION
/"" rd-r ~ , ~,.....
~ (~~c..,. \
~~.t1fo/~-_._ \
'. ---....., . --" .. ..-
......'Ia.....~o;,;;' "';-VY~~CIII I.JC;:'H.,
Page 3.
Rev.
CHAPTER III
System Design
This section will cover the proper design of the Pyro Chem Res-
taurant Fire Suppression System. It is divided into four (4) sections:
1. Nozzle Coverage and Placement.
2. Cylinder Sizing.
3. Piping Limitations.
4. Detector Requirements.
Each of these sections must be completed before
attempting any installation.
SECTION 1
Nozzle Coverage and Placement
This section will provide guidelines for determining nozzle
type, positioning, and quantity for duct, plenum, and
appliance protection.
A. Duct Protection
The following three (3) nozzles have been developed for
the protection of exhaust ducts;
1. Model NL-P.
2. Model NL-D2.
3. Model NL-D3.
Each nozzle is approved for use with the exhaust fan dampered,
undampered with the fan on, or undampered with the fan off. It
is not required that the fan be shut down or the exhaust dud be
dampered for the system to operate properly. Each nozzle is
approved to protect exhaust ducts of unlimited length.
1. Model NL-P.
The Model NL-P nozzle is a one (1) flow point nozzle
designed for the protection of exhaust ducts. One (1) or
two (2) Model NL-P nozzles can be used on a single duct
branch.
A sir.gle Model NL-P exhaust duct nozzle can protect a square
or rectangular duct with a maximum perimeter of 50 inches
and a maximum one-side length of 17 inches. It can also
protect a round duct with a maximum circumference of 50
inches and a maximum diameter of 16 inches (see Figure 3-1).
The nozzle must be installed on the centerline of the duct and
aimed directly into the duct opening (see Figure 3-21.
Two (2) Model NL-P exhaust duct nozzles can protect a
square or rectangular duct with a maximum perimeter of
84 inches and a maximum one-side length of 34 inches.
They can also protect a round duct with a maximum
circumference of 84 inches and a maximum diameter of
26.5 inches. When two (2) Model NL-P nozzles are used to
protect a single duct the cross sectional area of the duct
must be divided into two equal symmetrical areas. The
nozzle must then be installed on the center line of the area
it protects and aimed directly into the duct opening (see
Figure 3-2.1).
2. Model NL-D2.
The Model NL-D2 nozzle is a two (2) flow point nozzle
designed for the protection of exhaust ducts. Only one (1)
Model NL-D2 nozzle can be used on a single duct branch.
A single Model NL-D2 exhaust duct nozzle can protect a
square or rectangular duct with a maximum perimeter of
75.5 inches and a maximum one-side length of 25 inches.
It can also protect a round duct with a maximum circum-
ference of 75.5 inches and a maximum diameter of 24
inches (see Figure 3-1). The nozzle must be installed on
the centerline of the duct and aimed directly into the duct
opening (see Figure 3-21.
3. Model NL-D3.
The Model NL-D3 nozzle is a three (3) flow point nozzle
designed for the protection of exhaust ducts. One (1) or two
(2) Model NL-D3 nozzles can be IJsed on a single duct branch.
A single Model NL-D3 exhaust duct nozzle can protect a
square or rectangular duct with a maximum perimeter of
100 inches and a maximum one-side length of 33 inches.
It can also protect a round duct with a maximum circum-
ference of 100 inches and a maximum diameter of 31.75
inches (see Figure 3-1)
The nozzle must be installed on the centerline of the duct
and aimed directly into the duct opening (see Figure 3-2).
Two (2) Model NL-D3 exhaust duct nozzles can protect a
square or rectangular duct with a maximum perimeter of 150
inches and a maximum one-side length of 66 inches. They
can also protect a round duct with a maximum circumference
of 150 inches and a maximum diameter of 47.5 inches. When
two (2) Model NL-D3 nozzles are used to protect a single duct,
the cross sectional area of the duct must be divided into two
equal symmetrical areas. The nozzle must then be installed
on the centerline of the area it protects and aimed directly
into the duct opening (see Figure 3.2.1).
Nl-P
-:---~ -r-
Nt-D2
'-'-------,
I
2'" MAX
Nl-DJ
----~r
I
. -+- - --.. JI75' MAX
- I
,--__--L
,
'+'- - -~ ". MAX
" I
~________ L
, ~~_-.i.
2t + 2W _ SO' MAX
.'."--.
2l + 2W = 755' MAX
~t----~1
2l + 2W = 'CO' MAX
-----~--l-
~" --.., --- - -. w
~-~----'-
___-1..___~ ______.1_
_..1.
-'--L 117' ......Xl --....
-L 125' U"'XI--
L-l 133' V..VJ _
~-+---~-----.-
I _ i i
1- ~ - ~ le..5'!MAX
i . 1-1
~ 18_5' M...X -~
+-- - -~ - ~- 25' MAX
I I
I
I L
1----
f-- 25' ""....x --
,__0_ -.
- ---;... 12S """'X
i
I
~_J--1...
I
-12.5' "'AX--<
Figure 3-1. Duct Nozzle Coverage Limitations.
ULEX 3830
November 1, 1994
Rev. 1
.... tIC.~ _ ~ ....
.........tH ,.~z - 7!.S" *x
. .............. .......... P<<.-o3 - 1IOCr MAX
...2><. I ". .... ~
""" ", ~ ./
\ ~ <+~j::r
I / - //kF :
~ /' ".""
\ ?<<. ' , .! \
'" 't:./ ..' . ......... // ;
~. '.j,/
~~
---r
I .
. . 'I
-,---'$----'1..
. i :ti
;-1./2 ---J
Figure 3-2. Single Nozzle Placement In Duct.
......
:~t.r''''''''-U''''''lC
<~ ""~7J 4 I~' WAll
,-', '.....
~ "-- ......./'>-:
r ! :'---/"./
I ' .~ ./.
..>.-~, .~
\ L.~"'./ ./ ,;.... I '\
<'. .:;- '" 1,./ \
-~
___......t_ ~- - ,~ ..."x
-;"- ~-oJ - ISO" WAX
.;'~
,." '-:;,
#--; ~;.
. 1/'
\~.
( .~ ~"'}'--l
~,~/
~;
/~.
/ : ':
-J:~-'-:-'-~'-r-
~"""" : ..., "" -
~'I
. ----.:
--r
. , I
-L'-;'-'-._.~'--r ~
! . l.:u
...J v. to- ~ V. ~
~,~
Figure 3-2.1. Dual Nozzle Placement In Duct.
Duct Nozzle Coverage Chart
MA..mfUl\l ;\IAXOfUl\l
:-lOZZLE SIDE PEROIETER FLOW POI:\lS
NL-P 17- so-
2 x NL-P 3-1- 84' 2
NL-D2 2S" 75' 2
J
Nl.-D3 " 100"
2 x NL-D3 66" ISO" 6
NOn:: A SI:iCLE DUCT BRANCH CAN Oi'iL), SUPPORT:
I) A Sincte I\"L-P
2) A Single ~"L-D2
3) A Sinc1e NL-D3
-I) Two :'lL-P's
S) Two :'lL-Dl's
B. Plenum Protection
The Model NL-A nozzle is a one (1) flow point nozzle that
has been developed to protect the plenum section of the
exhaust hood. Only one (1) Model NL-A nozzle can be
used on a single plenum branch. A single Model NL-A can
protect a plenum (with single or V-Bank filters) with
rectangular dimensions of 8' x 4' or less. Larger plenums
can be protected by dividing the hazard area so that each
nozzle protects an area of 8' x 4' or less (see Figure 3-3).
The nozzle(s) must be located at the center of the V-Bank
width or centered between the filter width when used with
a single bank filter plenum. It must be within 4" of the wall
it is mounted against (see Figure 3-4), or within 4" of the
edge of the protected zone. .
...(1
/~~
..
:)J
/'
Figure 3-3. Plenum Coverage Limitations, Model NL-A Nozzle.
.EX 3830
,vember 1, 1994
3.1. De~p Fat Fryer Coverage.
The Model NL-F2 nozzle is a two (2) flow pOint nozzle that is
used for the protection of a single vat of a deep fat fryer. The
maximum area that can be protected by a single NL-F2
nozzle is:
1. Cooking Area: 18" x 18"
2. Integral Drip Board: 18" x 9.75"
The nozzle must be located within 11.875" of the center of the
longest side. and within 7" of the center of the shortest side of
the cooking surface and aimed at the center of the protected
zone. The nozzle must be mounted 30" to 42" above the top
surface of the deep fat fryer (see Figure 3..a.2).
The tip of the Model NL-F2 nozzle has two flat areas
designed to assist aiming. The nozzle must be positioned so
that these flat areas are parallel to the longest side of the
protected zone. See Figure 3..a.1.
NOTE
Nozzle shall be located anywhere in the shaded area and
aimed at the center of the protected zone.
Figure 3-8.2. Model Nl-F2 Nozzle Placement, Deep Fat Fryer.
chapter 3 - System DesK
Page 3-
Rev
NOTE
For installations that require the use of the Model NL-F2
nozzle to protect a deep fat fryer in accordance with Deep
Fat Fryer Coverage shown here (See Figure 3-8.21, the
following additional restrictions apply to the main supply
line piping:
1. Minimum length, linear: 8 feet
2. Miminum lentgh, equivalent: 14.1 feet
3. Minimum system flow points: 4
4. Minimum branches (total): 3
UlEX 3830
Apn/1,l995
" //~I
30' _ 34" :
~/ :
//i' /~.
~/, :
!,'--, /'
1'-....... /'
~ 'Y:/.~' ,-. //
'. . A~~ ",,"
Y' ~. ~"'~
1"-3- ''''~. ~':~~~~.'
lo!>~~
-, ~ ,~
~//"~~~
1"'}/~\
I~ 11
~/
Figure 3-13. Model NL.UB Nozzle Placement. Qosed Top Chain Broil...
b. Open Top Chain Broiler Coverage.
The Model NL-A nozzle is a one (1) flow point nozzle that is
used for open top chain broiler protection. The maximum
area that can be protected by an NL-A nozzles is 32. x 34.,
The nozzle must be located over the opening and aimed at
the center of the protected zone. The nozzle must be mounted
10" to 22" above the cooking surface. See Figure 3.14.
NOTE
Nozzle shall be located anywhere in the shaded area
and aimed at the center of the protected zone.
I
I ] I
~
Figure 3-14. Model NL-A Nozzle Placement. Open Top Chain Broil...
-~Re~.
9. Wok Coverage.
The Model NL-R nozzle is a one (1) flow point noZzte that
is used for wok protection. A single NL-R nozzle can cover
a single wok of 14. to 24. in diameter.
The nozzle must be mounted 40" to 50" above the cooking
surface at a radius of 12" from the center of the wok,
regardless of wok diameter. The nozzle must be aimed at
the center of the protected zone. See Figure 3-14.1.
NOTE
Nozzle shall be located anywhere in the shaded area
and aimed at the center of the protected zone.
~t" OiL .........-.....,......_____.............
.-
( \
b ...-- --..........(,/
{/'.--. . ~--,.,;.~-"
... ,. ..........,
. "'- . . " 'r--
~/....... '
U. 01.. Max. ~ ' to"
..........f'
I
I
40"
......................
.... 1...
Figure 3-14.1. Model NL-R Nozzle Placement, Wok.
ULEX
November' .
lpttf 3-~stem Design
le 3-6
1.1 '
be mounted 15" to 35- above the cooking surface. See
Figure 3-1'.
NOTE
Nozzle shall be located anywhere in the shaded area
and aimed at the center of the protected lone.
--r
I
I
I tr.U"
I
I
!
I
I
i
./
Flgur. 3.11. MocW NL.A Nozzle PiMement. an..-A-
ChnroI1er.
7. Upright Broiler Coverage.
The Model NL-UB nome is a one-half ('/,) flow point
nozzle thet is used for upright broiler protection. Two (2)
Model N~-UB no~les are commonly used for this
application. The purpose of using two nozzles is to
dlstrlbut. the chemical evenly between the cooking
surflce (on top) and the drip pan (below). For upright
broilera that have no drip pan, a lingle Model NL-UB
nozzle ~n be u-.d. The maximum area that can be
protected by . pair of NL-UB nozzle. (or elfngle NL-UB
nozzle when no drip pan is present) is 30- x 34-.
One nozzle must be poSitioned In the front entrance of the
broiling chamber and aimed at the diagonal corner. The
nozzle will be poaitloned above the cooking surface. If
necessary, the second nozzle must be installed above the
front edge of the grea.e drip pan and aimed at its
midpoint. See Figure 3-12.
W';Y
V
/...:
/
NL-UB Nozzle Placement, Upright Broiler.
iler Coverage.
Two types of c in broilers are commonly used; open and
closed top. Eae is protected in a different mann~r.
.. Closed Top ain Broiler Coverage.
The Model NL- B nozzle is a one-half ('I,) flow point
nozzle that is u ed for closed top chain broiler protection.
Two (2) Model L-UB nozzles are commonly us~ for this
application. Th purpoH of using two nozzles I',to
distribute the leal evenly between the CO(l~ng
Iurface (on to and the drip pan (below). For cl~sed top
chain broilers at have no drip pan, a single MQdel NL-
UB nome can UMd. The maximum area that can be
protected by a pair of NL-UB nozzl.. (or a singl~ NL-UB
nozzle when n drip pan Is present) is 30- x 34- ~
One nozzle m at be positioned In the front entr.nce of the
broiling cham r and aimed at the diagonal comer. The
nozzle will be ltIoned above the cooking surface. The
second nozzle (If necessary) must be installed above the
front edge of e grease drip pan and aimed at lts
midpoint. See FIgure 3-13.
.'
Commercial Fire Equipment Co.
=-:: =- ~'. -3 :.. =-=--. ::.=i_:!.~\1 =~i-
P. O. sox 2.1.12. 3RANDON. ,=LORID.'; 33509.2<1.:12
MANUAL
PULL
CHEI\IICAL
CYLINDER
?HCI'lE: 6=4.3357
FUSIBLE
LI N KS
PIP!NG
CA BLE OPERATED
GAS SHUTOFF
VALVE
,.
~
.'
',oCommercial Fire Equipment Co.
FIRE & SAFETY EQUIPMENT
P. O. BOX 2442. BRANDON, FLORIDA 33509.2442
PHON E: 654-3357
tl ::r:
c:: 0
() 0
>-3 tl
en t"l
I-t tIj
N Z
tIj (j)
>-3
::r:
N