Loading...
HomeMy WebLinkAbout02-1229 ~ Itf~,~O BUILDING BUILDING PERMIT CITY OF ZEPHYRHILLS Permit N! (813) 780-0020 Lj2~ro 1j'f1V PLUMBING ~CHANICAL 1229 Date .)- / ~ ~. C?~ ~o.&~ n.ECTRICAL Sewer Conn Water Conn: Property Owner: Job Address: Parcel I. 0, II Zoning: Descriotion of Work ~~ ~ 6:1-';<- !:';:.dG (p ; I V ' ovL ' . Water Meter: T.I.F.'s: Energy Code: ~ G-vv~ Radon Gas: (h i:2. k) I f)(' l? C\ (id/ft~ IV FINAL / ~ - /1-// :2 DATE NO OCCUPANCY BEFORE C.O. Complete Plans, Specifications and Fee Must Accompany Application, All work shall be performed in accordance with City Codes and Ordinances. c.o. DATE Inspector A2 if /!6-0 / Permit Fee ,Pignature Company Address )Telephone# ~&~ Valuation or Contract Price / L/. 73(), (f() , City License Registration # State Certified License# 2 - 11/115 c.:::-kc.5RI/, -117& CAr;5 b....hy'j. ?(uYn!.1 -11(6 fu0$ ~~ iff I MECHANICAL c. C 5N-vo-e f ~. PLUMBING SLB ,/1 -S-fi::2. pLY Tub Set L/7-_7o-0'z.R('f Water Sewer /9-/j.'/)"l- IP', l2~r Final ../ /1- 25" c:' 2'- I2L'J IpTcl BUILDING ELECTRICAL Ftr, 4 -1/-tJ:l.. /(L I( JIJO Tp. Serv, Pre SLB )~t/-I/-t?:2. Kt~~ROU9h In~/7-;27-p;2 &3 Lintel lL_ - 2 - 0:;).. R t. _ Meter Can FRM. ./7-~Q" 0 2 f2L~ Const. Pole Insul. CL Pool WL Pre-Meter Final 7f/}.. - II -- C (). ft- Lt Breakers Ducts Insl. Compressor Final ,.///-2S'.di'L /<.l'f II-:Fl..' DriVeWay~ c L fth; (\ . - 7 -- /5-- 0';) R (J... ) rlJl&' d 7 REINSPECTION FEES: When extra inspection trips are necessary due to anyone of the following reasons, a charge of twenty-five and 00/100 Dollars ($25,00) shall be made for each trip for each trade: a, Wrong Address b. Condemned work resulting from faulty construction. c. Repairs or corrections not made when inspection called. d, Work not ready for inspection when called, e. Permit not posted on job site. f, Plans not at job site. g. Work not accessible. The payment of inspection fees shall be made before any further permits will be issued to the person owning same, ) Gil-f'iL S- /&." o:J- J:-t" i l_.::.-.- --"--_...__~ APPLICATION FOR PERKIT CITY OF ZEPHYRHILLS BUILDING DEPARTMENT , . OWNERtS NAME 6etA-i-J ~ L..'lV6A 0U61-ETTt OWNER t S ADDRESS --[p'J..0'6::'1 uJ0t (!).ktc s De.. I. PHONE 1 ~~ - '::;;) (p rt JOB ADDRESS 4>cJ.O q SIu/8L QA--lC5. De.... LEGAL DESCRIPTION: LOT(S) BLOCK SUBDIVISION SILU U- otlt-IC S PARCEL I. D -. ~ - a (0- d \ - Ol3.B -CXIX1) -aJ9D (OBTAIN FROH PROPERTY TAX NOTICE) WORK PROPOSED:_New Construction ~Addition _Alteration _Repair _Install _Sign _Hove _DeJIOlish PROPOSED USE: ~Single Faaily _H/F _' of Units ---.Jl/H _eo..ercial _Indust. _Swia. Pool _Other _Restaurant & Health DepartJllent Approval DESCRIPTION OF WORK: CJ:>tJ~'"f"e.VcrL(},J_..O~_CO,0~~ ~.J..oc.lL ~Pl-rlO)...J r I) / X r'2. / I /Y. BUILDING SIZE: e: ,~;"I ~ Square Feet. Height RESIDENTIAL: ATTACH (2) PLOT PLANS & (2) SETS OF BUILDING PLANS & (1) SET ENERGY FORMS. COHHERCIAL: ATTACH (3) SETS OF BUILDING PLANS & (1) SET ENERGY FORMS. PROPERTY SURVEY REQUIRED FOR ALL NEW CONSTRUCTION. PERMITS REOUESTED -=:::"'BUILDING $ d.7.75l),oeJ ,.........- _ELECTRICAL vMECIIAHlCAL ~ PLUMBING AttP Service Valuation of Total Construction t/'/ Florida Power Corp. W.R.E.C. $ Valuation of Mechanical Installation GAS ROOFING SPECIALTY TYPE OF CONSTRUCTION: _Block _Fraae _Steel Other FINISHED FLOOR ELEVATIONS: FT. IS PROJECT IN FLOOD ZONE AREA? YES NO ****************************************** CONTRACTOR SECTION 1Z 1 Z;L~ ql/ BUII.DER COMPANY G.l, SYE'lE. COD~l, <l!s~ State Cert. or Regist.' . . cec- oa.a ,;J 1 City License Registration f 2> ey:;;; ~ **************...*......****.****.*.*.**** Signature F.r:::ClAR I~ COMPANY -y gJ.Wl1.!.l< lJ-> E:l.i.::-cnLLL SaW:,;! ~ State Cert. or Regist.' Coo;nc.,g Si City License Registration f q0 *************.**************************** PLUMBER ~ COMPANY /2 . ""~-,,/ /7 LJ /I State Cert. Signature U A:-. ~ ~ .I'~ City License Registration t *********************.************..**..** MECHANICAL COMPANY .Lf'</H..e/~ /~ ~~ 0A.5 t..-4/'C ~~d State Cert. or Regist. C"'COYJ'7Y>' Signature ~. .,/'::: -- City License Registration' / 7 *****************.*********************.** OTRRR ~ignature COMPANY State Cert. or Regist. f City License Registrati ************************************ APPLICATION APPROVED BY * .~ ~":.. . PERKI T OFFICER....:. ...-; ..."'- .._~- _.~.~~ _00 eM ......., __.....--. ,! ~t CONDITIONS OF PERMIT AFFIDAVIT A. NOTICE OF DEED RESTRICTIONS Tbe undersigned understands that this perlit lay be subject to "deed restrictions" which .ay be lOre restrictive than City regulations. The undersigned assUles responsibility for cOlpliance with any applicable deed restrictions. B. UNLICENSED CONTRACTOHS AND CON1'RAC'l'OH RESPONSIBILITIES If the owner has hired a contractor or contractors to undertake work, they .ay be required to be licensed in accordance with state and local regulations. If the contractor is not licensed as required by law, both the owner and contractor .ay be cited for a lisde.eanor violation under state law. If the owner or intended contractor are uncertain as to what licensing reguirelents .ay apply for the intended work, they are advised to contact the City of Zephyrhills Building Departlent, (813) 188-6611. Furtherlore, if the owner has hired a contractor or contractors, he is advised to have the contractor(s) sign portions of the .Contractor Sections" of this application for which they will be responsible. If you, as the owner sign as the contractor, you are indicating that you, rather than tIle contractor, are responsible for the work. If the contractor wishes you to sign as contractor that lay be an indication that he is not properly licensed and is not entitled to per.itting privileges in the City of Zephyrhills. C. TRANSPORTATION IMPACT FEES AND UTILITY CONNECTION FEES I ~' , D. CONS1'RUC'l'ION LIEN L'I\.W (CHAPTER 713, FLORIDA STA'rUTES, AS AMENDED) I certify that I, the applicant, have been provided with a copy of "Florida's Construction Lien Law _ Hoteowner's Protection Guide" prepared by the Florida DepartJent of Agriculture and ConsUler Affairs. If the applicant is sOleone other than the "owner", I certify that I have obtained a copy of the above described doculent and pro.ise in good faith to deliver it to the "owner" prior to co..encelent. E. CONTRACTOR' S/OWNER' S AFFIDAVI'l' I certify that all the inforlation in this application is accurate and that all work will be done in cOlpliance with all applicable laws regulating construction, zoning, and land developlent. I Application is hereby lade to obtain a perlit to do work and installation as indicated. I certify that no worl or installation has cOllenced prior to issuance of a perlit and that all work will be perfoCled to leet standards of all laws regulating construction, City codes, loning regulations, and land developlent regulations in the jurisdiction, I also certify that I understand that the regulations of other goverDlental agencies lay apply to the intended work, and that it is ,y responsibility to identify what actions I lust take to be in co.pliance. Such agencies include but are not li8ited to: t DepartJent of EnviroDlental Regulation - Cypress Bayheads, Wetland Areas and Bnvirofilentally Sensitive Lands, Nater/Nastewater Treatlent t Southwest Florida Water Hanagelent District - Wells, Cypress Bayheads, Netland Areas, Altering Watercourses t ArlY Corps of Engineers - Seawalls, Docks, Navigable Waterways t DepartJent of Health & Rehabilitative Services, BnvirODlental Health Unit - NeIls, Wastewater Treatlent, Septic Tanis t US BnviroDlental Protection Agency - Asbestos abatelent I also certify that, if fill laterial is to be used in Flood Zone "A" or "A,etc.", it is understood tbat a drainage plan addressing a "colpensating volUle" will be sub.itted which is prepared by a professional engineer registered in the State of Florida prior to perlit issuance. . A perlit issued shall be construed to be a license to proceed with the work and not as authority to violate, cancel alter, or set aside any provisions of the technical codes, nor shall issuance of a perlit prevent the Building Official frot thereafter requiring a correction of errors in plans, construction, or vioiations of any code, Bvery peClit issued shall heCOle invalid unless the work authorized by such perlit is cOllenced within six lonths of issuance, or if work authorized by the per.it is suspended or abandoned for a period of six IOnths after the tile the work is cOllenced. One 90 day eatension of tile, tay be allowed for the perlit with fee charge of $15.00. The extension shall be reguested in writing to the Building Official. An approved inspection lust be logged during each six IOnth period, or the project will be considered abandoned. NARMING TO ONNER: YOUR FAILURB TO RECORD A NOTICB OF COHHENCKHENT HAY RESULT IN YOUR PAYING fNlCE FOR IHPROVEHBIrS TO YOUR PROPBRTY. IF YOU IHTHND TO OBTAIN FINANCING, CONSULT NITH YOUR LHNDBR OR AN ATTORNBY BBFORB RBCORDING YOUR HOTICH OP COHHHNCHHHNT. JOBS UNDER $2,500 IN VALUH DO NOT NEHD TO RECORD AND POST A "NOTICH OF COHHKNCKMKHI". / '~ ~ttQrd]t . S~ RE: ONIIIlR OR A ;T' i ~\J$~ SIGNATURE: CONrHAe R . I STATE OF FLORIPGl COUNTY OF 't' Q 'S C 0 The foregOing instrument was acknowledged before me this ~J.ftl~)".. \, 1:9:QQt by k "' N ()ft G u. 'e.l' lGt1- ~ w 0 is personal If known to me or W"h,O, has produced i- t D J-.... ,_ as ide,n tification,.and wbo did~id noJ) ~~~,d,~~ ~JVL (~~{-~ A 'T ;~.~ N ~ \ (Name Typed, Printed or Stamped) NOTARY PUBLIC STATE OF FLOR~ COUNTY OF ~ Q C;C' .f) The foregoing instrument was acknowledged before me this A~'\ \dS , t9"d.O~y ~~o...' ~~ who is personally known to me or who bas produced ~ L '\::) L as identification and who di~id nQt) ta oatb. II""""",' ..... -- --... - .... -- ,......._...... CITY OF "NOTICE" BUILDING ZEPHYRHILLS DEPARTMENT OF ADD.ITION OR CORRECTION /'1/36 I ADDRESS DATE PERMIT.,. I 020<(( ~ ~4 r ///2S-02- /26 r THIS JOB HAS NOT BEEN COMPLETED The following additiqns or corrections shall be made before the job , . will be accepted, DO NOT REMOVE g~ G~/~ ~ L/rl-r~ ~Aj ~ 2. / CJ, / It ia unlawful far any Carpent.r, Cantractor, Bulld.r, or ath.r peraana, 10 cav.r or cau.. to be cov.red, any part of th. work with flooring, lath, earth or oth.r material. until the proper Inapector haa had ampl. 11m. to approve ,h. ina'allallon, . AFTER CORRECTIONS ARE MADE CALL 78~6~:ON INSPECTOR ---------- OFFICE HOURS 8 - 5 MON.-FRI. 01/ ,~~ ).w. SMITH ENGINEERING CO. Mechanical & Architectural Enl!ineerine: Phone: 352-521-0865 David W. Smith, P.E. 9909 WaUaston Drive Dade City, Florida 33525 Fax: 352-521-0867 E-Mail: zeDhvr27~e:te.net June 27, 2002 REF. Substitution of Wood Frame wall for block wall 6UeeETT"E" - b-108 S/L."Ee. O,6...t~ i:)~ ~"l~U'('u I hereby certify that the substitution of a 2'X6' wood frame wall (with provisions as specified in the following paragraph) located at bath adjacent to lanae in place of a blockwall as shown on the original plan cop lies with section 1606 & all applicable sections of the Florida Building code. Provisions&Specifications for said wall substitution: The frame wall is to have 'l2"X6" 'J' bolts @ bottom plate located 24" a.c. max, Simpson SP1&SP2 Clips or equiv at top and bottom of stud to plate connections. Studs at end of walls to be fastened to block walls with 'i4"X3" Tapcons. Wall to be finished with wire lathe and stucco to match. David ~~ &( & 1/b~ G.L. Steve 6208 Silver Oaks Dr. SQ. FEET PRICE MAIN OR LIVING: 204 $ 40,00 OTHER AREA UNDER ROOF: 438 $ 15,00 OTHER: $ - VALUATION $ 14,730,00 FEE SHEET $ 95.00 ADDRESS $ - DRIVEWAY $ - BUILDING: $ 142,50 CREDIT: $ - BUILDING LESS CREDIT: $ 142,50 ELECTRICAL: $ 30,88 PLUMBING: $ 42,50 MECHANICAL: $ 25.00 RADON: $ 6.42 TOTAL $ 247,30 SEWER: $ - WATER: $ - IRRIGATION: $ - TOTAL: $ - I I I I I WATER METER:I $ IRRIGATION METER $ SUB-TOTAL $ 247.30 I SIPS:I $ 97,5% $ 2,5% $ TIF'S:r 99% $ 1% $ - I - I TOTAL: $ 247.30 I State of F L-OeL oA- County of 1111111111111111111111111111111111111111111111111111 1111111\ 2002064420 " Rcpl: 583871 Rec:, 6.00 DS: 0. 00 IT: 0 . 00 04/25/02 Dpty Clerk JED PITTMAN~ PASCO COUNTY CLERK 04/25/02 llO: 24am 1 of 1 OR BK 4929 PG 96 fA? eo Permi t No. NOTICE OF COMMENCEMENT THB UNDERSIGNED hereby give~ notice that improvement will be made to certain real property, and in accordance with Chapter 713, Florida Statutes, the following information is provided in this Notice of Commencement: 1. Description of Property: Parcel No.3-OIo.81:..QJaft-t::fr:rtl- CD90 3. (Legal description of the property and street address if available) 2. Gt::1:&t::J.al DescLi~ticn of Improv~mcnt (lo~STe..uc.T( c).LJ Of- \~' )( C;;; 3' 1../' ~o).JCJlt(E:. 6'Loc.lC. A-P"01T (Ot--J I QnDs\s, T I.DC:, 0 ~ 6B/~. 6A-rr\. A0 1.A-VA\ O\'lncr Information: Name ~lMJ ~ L'-(AJ~A Gu~~ Address ~ ;)0$2 S/LVtlL O~~ ~ity Lt:~~e.4fu~ State h 33~( J Interest in Property: Name of Fee Simple Titleholder: (If other thsn owner) Address City State 4. Contractor: Name G.L. SfEY'1C. 0..vPS-r. Addresf? '37(b( <61"'rt IN City "ZePlk'-lf.kkLU State FL ~3Cl1/ 5. Surety: Name Address City State Amount of Bond: $ 6. Lender: Name Address City State 7. Persons within the State of Florida designated by Owner upon whom notices or other documents may be served as provided by Section 713.13(1)(a)(7), Florida Statutes: Name Address City State 8. In addition to himself, Owner designates of to receive a copy of the Lienor's Notice as provided in Section 713.13(1)(b), Florida Statutes. (l:Xl'l1ttl.''iou uttl.o of NoLice of COllUlloucolllouL (Lhe expiration daLe is 1 year fr~m ttle date of recording unless a different date is specified.) 9:. J Signature of Ownerd~ ( ! 1l(/J~Jj; I Sworn to and subscribed before me this ~ day of ....A.f \,', \ 19 Od.. · . ~.......- 1 ' .......... Notary Public: If: LL '\- '^- 1\ '\ ~ ~ N e.- .. ..,~ ~~... '. MyCommissionExpires:G ~ Q 1- ~_ I , .,JD ''c... r. ;,'If-j' r. ~'1' (/ft.) ~ ~ , . "'" ~\J\ " (, - ..... ~\1\ <;) ~. ~ ~ ~/ --("'O-R.'~rr ~~~'~ ,.,'>7 .s. ~/..~ ' ~/ EPt>>C OF \01" .. !::'a, /.:) , . A Z 3. 4' ""'.~ / ..s: $1 3o!!J' l.4.J ( ". · ,(, IlO.DO" u' _ " ~ 1 ~..., -e'< 180 ~s W. ;.,.)' ~ I ~ (B.,~s. .. 'l A' 4'. 3e>, e - ., ::6: f'. 'f>: "'41., i'!'" <1.1.Iz.o 'f)" . D..,. V roc '" Itr -.L ~ " c: fl./jf~:) , AI. 4'1 '* 58 .~., !; .s, ~-,rn..&AI. {-;.Q- ~ S'., -. ~:41. 7" ('At 1': ~I /V: 4 S3 57 e s,.,. JZ."~'~7 (/0<. MI,o-f(f':) loA" ......,......../ ry .. \)_ - ----- ~.., Sc... e AI r- .,'::tr 10 S. 7 S '( . 1'..AJ~' _ /0"'7"("',; $IP~~~ . r.z, fro) z. 3-Z' ('No) .~ \ ~ \ .. -./ . ~, '" ~ . ~~ "'-\. ~'" t:,' " ,~ t:) , ~I\) \1Il\:) ~: ~ .. ~ ,,~ ^ '\ / "1.. <"0 ~ d' /~. ~ ~.... JC-..r~ <:; ~ "t.. ~ ^" .... '\ '~ 7 <~ ~ ~ "% <b c:;;~ 'tc- ~~ ~ ~ ~ t ~ ~ 'l:' "L .s;, "- - N~ ~~ -~ ~.~ ~ -./v tZ ,of ' ,"- ~ ,;, .~ /' .,. ..> 11'X36"-iJ' . J...ANA I ~~~~ ~ a -';._~> c:, ~ ~. J;- · 'l#o~ ~ .'" ~ ~ tl 411 ~ .. -t" ^ ..s- ~ ~1.5 . '.S' " "- ~ I\J ~ ~, () ~ \oN () "\ '~ ,,"-' v LOr /~ o ?"~ ~ IZ'Xl7' 6~00M. .- T 15 ')(~' Pa(.' ~ 1t5' ~~ '-- '7' ,.. <1~ "'... ~ . .. ,..~~ 10' ptA-r ~~~ r..) ~... s, 44. 5 S 's 5 "<<1. _ 7 5.73'(,..) - z,02-, ~o .w~ 5.4"" 5.5' ~S..... - TS. 74 '('"N.) s. 3~:~~,.,,) 'Ci.~+~ z, ,0 '2. ~ ~ '(,.. J .,...r~ s.J& ","1 ./ ~. ___~~, :;;_ ~;~;= _ ~-;,~~_~_ ___ _ LrI, ~ ~8'''t'l..' ~ (J,~ ct~'~,.. , '~ 6~~ '" .,. '" '... ~~ FORM 600A-2001 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Community Affairs Residential Whole Building Performance Method A Project Name: Address: City, State: Owner: Climate Zone: Garrett Addition 6208 Silver Oaks BLVD. Zephyrhills, FL Garrett Central Builder: G.L Steve Pennitting Office: Pennit Number: Jurisdiction Number: 1, New construction or existing 2, Single family or multi-family 3, Number of units, ifmulti-family 4, Number of Bedrooms S, Is this a worst case? 6, Conditioned floor area (ft2) 7, Glass area & type a. Clear - single pane b, Clear - double pane c, Tint/other SHGC - single pane d, Tint/other SHGC - double pane 8, Floor types a, Slab-On-Grade Edge Insulation b, N/A c, N/A 9 , Wall types a, Frame, Wood, Exterior b, N/A c, N/A d, N/A e, N/A 10, Ceiling types a. Under Attic b. N/A c, N/A I I. Ducts a, Sup: Unc, Ret: Unc, All: Attic b. N/A Addition Single family I I No 204 ft2 0,0 ft2 0,0 ft2 0,0 ft2 7,5 ft2 R=O,O, 58.0(p) ft R=13,O, 480,0 ft2 R=30,O, 642,0 ft" Sup, R=6,O, 40,0 ft 12, Cooling systems a, Central Unit Cap: 5,0 kBtuIbr , SEER: 10,00 b, N/A c, N/A 13, Heating systems a, Electric Heat Pump Cap: 5,0 kBtuIbr HSPF: 7,00 b, N/A c. N/A 14, Hot water systems a, N/A b, N/A c, Conservation credits (HR-Heat recovery, Solar DHP-Dedicated heat pump) 15, HV AC credits (CF-Ceiling tan, CV-Cross ventilation, HF"Whole house tan, PT -Programmable Thermostat, MZ-C-Multizone cooling, MZ-H-Multizone heating) CF, _ Glass/Floor Area: 0.04 FAIL Total as-built points: 5189 Total base points: 4825 I hereby certify that this building, as designed, is in compliance with the Florida Energy Code. OWNER/AGENT: DATE: Review of the plans and specifications covered by this calculation indicates compliance with the Florida Energy Code. Before construction is completed this building will be inspected for compliance with Section 553.908 Florida Statutes, BUILDING OFFICIAL: DATE: EnergyGaugee (Version: FLRCPB v3,21) FORM 600A-2001 WATER HEATING & CODE COMPLIANCE STATUS Residential Whole Building Performance Method A - Details ADDRESS: 6208 Silver Oaks BLVD., Zephyrhills, FL, PERMIT #: BASE AS-BUlL T WATER HEATING Number of X Multiplier = Total Tank EF Number of X Tank X Multiplier X Credit = Total Bedrooms Volume Bedrooms Ratio Multiplier 1 2564,00 2564,0 1 1,00 2564,00 1.00 2564,0 As-8ulIt Total: 2184.0 CODE COMPLIANCE STATUS BASE AS-BUlL T Cooling + Heating + Hot Water = Total Cooling + Heating + Hot Water = Total Points Points Points Points Points Points Points Points 1480 781 2564 4825 1603 1022 2564 5189 I FAIL I .. EnergyGauge 11Il DCA Form 6QOA-2001 FORM 600A-2001 WINTER CALCULATIONS Residential Whole Building Performance Method A - Details ADDRESS: 6208 Silver Oaks BLVD., Zephyrhills, FL, PERMIT #: BASE AS-BUlL T GLASS TYPES .18 X Conditioned X BWPM = Points Overhang Floor Area Type/SC Omt Len Hgt Area X WPM X WOF = Point .18 204.0 5.88 215.2 Double, Tint E 1,0 2,0 7,5 5,01 . 1.06 39,8 As-8uilt Total: 7.5 38.8 WALL TYPES Area X BWPM = Points Type R-Value Area X WPM = Points Adjacent 0,0 0.00 0,0 Frame, Wood, Exterior 13,0 480,0 1,80 864,0 Exterior 480,0 2,00 960,0 Base Total: 480.0 HO.O As-Butlt Total: 480.0 884.0 DOOR TYPES Area X BWPM = Points Type Area X WPM = Points Adjacent 0,0 0,00 0,0 Exterior Insulated 21,0 5,10 107,1 Exterior 21.0 5,10 107,1 Base Total: 21.0 107.1 As-Built Total: 21.0 107.1 CEILING TYPES Area X BWPM = Points Type R-Value Area X WPM X WCM = Points Under Attic 204,0 0,64 130,6 Under Attic 30.0 642.0 0.64 X 1,00 410,9 Base Total: 204.0 130.8 As-Bullt Total: 842.0 410.8 . FLOOR TYPES Area X BWPM = Points Type R-Value Area X WPM = Points , Slab 58:O(p) -1.9 -110.2 Slab-On-GracIe Edge Insulation 0,0 58.0(p) 2,50 145,0 Raised 0,0 0.00 0,0 Base Total: -110.2 As-Built Total: 18.0 141.0 INFILTRATION Area X BWPM = Points Area X WPM = Points 204,0 -0,28 -57,1 204,0 -0,28 -57,1 Winter Base Points: 1245.5 Winter As-Built Points: 1509.7 Total Winter X System = Heating Total X Cap X Duct X System X Credit = Heating Points Multiplier Points Component Ratio Multiplier Multiplier Multiplier Points (OM x DSM x AHU) 1509,7 1.000 (1,078 x 1,160 x 1,11) 0,488 1,000 1021,7 1245.5 0.6274 781.4 1509.7 1.00 1.388 0.488 1.000 1021.7 EnergyGauge 1111 DCA Form l5OQA-2001 FORM 600A-2001 SUMMER CALCULATIONS Residential Whole Building Performance Method A - Details ADDRESS: 6208 Silver Oaks BLVD., Zephyrhills. FL, PERMIT #: BASE AS-BUlL T GLASS TYPES ,18 X Conditioned X BSPM = Points Overhang Floor Area Type/SC Omt Len Hgt Area X SPM X SOF = Points .18 204.0 26.78 946.6 Double, Tint E 1.0 2,0 7,5 44,33, 0.74 244,9 As-Bullt Total: 7.6 244.8 WALL TYPES Area X BSPM = Points Type R-Value Area X SPM = Points Adjacent 0,0 0.00 0,0 Frame, Wood, Exterior 13,0 480,0 1,70 816,0 Exterior 480,0 1,90 912,0 Base Total: 480.0 912.0 As-Built Total: 480.0 818.0 DOOR TYPES Area X BSPM = Points Type Area X SPM = Points Adjacent 0.0 0,00 0,0 Exterior Insulated 21,0 4,80 100,8 Exterior 21.0 4,80 100,8 Base Total: 21.0 100.8 As-Bullt Total: 21.0 100.8 CEILING TYPES Area X BSPM = Points Type R-Value Area X SPM X SCM = Points Under Attic 204,0 2,13 434,5 Under Attic 30,0 642,0 2.13X 1,00 1367,5 Base Total: 204.0 434.6 As-Built Total: &42.0 1387.6 .. FLOOR TYPES Area X BSPM = Points Type R-Value Area X SPM = Points Slab 58,O(p) -31.8 -1844.4 Slal>On-Grade Edge Insulation 0,0 58,O(p) -31.90 -1850,2 Raised 0,0 0,00 0,0 Base Total: -1844.4 As-Sullt Total: 68.0 -1860.2 INFIL TRA TION Area X BSPM = Points Area X SPM = Points 204.0 14,31 2919.2 204,0 14,31 2919,2 Summer Base Points: 3468.8 Summer As-Built Points: 3598.2 Total Summer X System = Cooling Total X Cap X Duct X System X Credit = Cooling Points Multiplier Points Component Ratio Multiplier Multiplier Multiplier Points (OM x OSM x AHU) 3598,2 1,000 (1,087 x 1,150 x 1,10) 0,341 0,950 1602,8 3468.8 0.4266 1479.8 3598.2 1.00 1.375 0.341 0.950 1602.8 EnergyGauge not DCA Form 800A-2001 Garrett 6208 Silver Oaks BLVD. Zephyrhills, FL System Sizing Calculations - Summer Residential Load - Component Details Project Title: Garrett Addition Code Only Professional Version Climate: Central Reference City: Or1ando (Defaults) Summer Temperature Difference: 18,0 F 4/17/02 Type Overhang Window Area(sqft) HTM Load Window PaneslSHGC/U/lnShlExSh Omt Len Hat Gross Shaded Unshaded Shaded Unshaded 1 2, Tint, DEF, B, N N 1 2 7,5 0,0 7,5 12 12 90 Btoo Window Total 8 90 Btuh Walls Type R-Value Area HTM ' Load 1 Frame - Exterior 13,0 480,0 1,7 835 Btuh Wall Total 480.0 835 Btuh Doors Type Area HTM Load l' Insulated-Exter 21,0 10,1 213 Btuh Door Total 21.0 213 Btuh Ceilings Type/Color R-Value Area HTM Load 1 Under Attic/Dark 30,0 642,0 1,4 912 Btuh Ceilina Total 642.0 912 Btuh Floors Type R-Value Size HTM Load 1 Slab-On-Grade Edge Insulation 0,0 58.0 ft(p) 0,0 0 Btuh Floor Total 58.0 0 Btuh Infiltration Type ACH Volume CFM= Load Natural 0,35 2040 11,9 236 Btuh Mechanical 0 o Btuh TotAl 12 2~ Rtuh .. Occupants 2 Btuhloccupant X 300 + Appliance 1200 Load 1800 Btuh Subtotal 4086 Btuh Duct gain(using duct multiplier of 0.10) 409 Btuh Total sensible gain 4494 Btuh Totals for Cooling Latent infiltration gain (for 44 gr. humidity difference) 357 Btuh Latent occupant gain (2 people @ 230 Btuh per person: 460 Btuh Latent other gain 0 Btuh TOTAL GAIN 5311 Btuh Key: Window types (SHGC - Shading coefficient of glass as SHGC numerical value or as clear or tint) (U - WIndow U-Factor or 'DEF" for default) (InSh " Interior shading device: none(N), BlindslDaperies(B) or Roller Shades(R)) (ExSh - Exterior shading device: none(N) or numerical value) (Omt - compass orientation) EnergyGaugd FlRCPB v3,21 Residential System Sizing Calculation Summary Project Title: Garrett Addition Garrett 6208 Silver Oaks BLVD, Zephyrhills, FL Code Only Professional Version Climate: Central 4/17/02 Location for weather data: Orlando - Defaults: Latitude(28) Temp Range(M) Humidit data: Interior RH 50% Outdoor wet bulb 6F Humidit difference 44 r, Winter design temperature 38 F Summer design temperature Winter setpoint 70 F Summer setpoint Winter tern erature difference 32 F Summer tern rature difference Total heatin load calculation 4647 Btuh Total coolin load calculation Submitted heating capacity 5000 Btuh Submitted cooling capacity Submitted as % of calculated 107,6 % Submitted as % of calculated 93 F 75 F 18 F 5311 Btuh 5000 Btuh 94.1 % WINTER CALCULATIONS Winter Heatin Load Load com onent Window total Wall total Door total Ceiling total Floor total Infiltration Subtotal Duct loss TOTAL HEAT LOSS 8 sqft 480 sqft 21 sqft 642 sqft 58 ft 14 cfm . Load 174 1248 316 706 1502 480 4426 221 4647 Btuh Btuh Btuh Btuh Btuh Btuh Btuh Btuh Btuh SUMMER CALCULATIONS Summer Coolin Load ft Load com nent Load Window total 8 sqft 90 Btuh Wall total 480 sqft 835 Btuh Door total 21 sqft 213 Btuh Ceiling total 642 sqft 912 Btuh Floor total 0 Btuh Infiltration 12 cfm 236 Btuh Internal gain 1800 Btuh Subtotal(sensible) 4086 Btuh Duct gain 409 Btuh Total sensible gain 4494 Btuh Latent gain(infiltration) 357 Btuh Latent gain(intemal) 460 Btuh EnergyGaugeCBl S Total latent gain 817 Btuh PREPARED TOTAL HEAT GAIN 6311 Btuh DATE: EnergyGaugellP FLRCPB v3,21 Garrett 6208 Silver Oaks BLVD, Zephyrhills, FL System Sizing Calculations - Winter Residential Load - Component Details Project Title: Garrett Addition Code Only Professional Version Climate: Central Reference City: Or1ando (Defaults) Winter Temperature Difference: 32,0 F 4/17/02 Window Panes/SHGC/FramelU Orientation Area X HTM= Load 1 2, Tint, Metal, DEF N 7.5 23.2 174 Btuh Window Total 8 174 Btuh Walls Type R-Value Area X HTM= Load 1 Frame - Exterior 13.0 480 2.6 1248 Btuh Wall Total 480 1248 Btuh Doors Type Area X HTM= Load 1 Insulated - Exter 21 15.0 316 Btuh Door Total 21 316Btuh Ceilings Type R-Value Area X HTM= Load 1 Under Attic 30.0 642 1.1 706 Btuh Cellina Total 642 706Btuh Floors Type R-Value Size X HTM= Load 1 Slab-On-Grade Edge Insul 0 58.0 ft(p) 25.9 1502 Btuh Floor Total 58 1502 Btuh Infiltration Type ACHX Building Volume CFM= Load Natural 0.40 2040(sqft) 14 480 Btuh Mechanical 0 o Btuh Infiltration Total 14 480 Btuh .. Subtotal 4426 Btuh , Duct Loss(using duct multiplier of 0.05) Totals for Heating 221 Btuh Total Btuh Loss 4647 Btuh Key: Window types (SHGC - Shading coefficient of glass as SHGC numerical value or as clear or tint) (Frame types - metal, wood or insulated metal) (U - Window U-Factor or 'DEF' for default) (HTM - ManualJ Heat Transfer Multiplier) Key: Floor size (perlrneter(p) for ISIab-on-grade or area for all other floor types ) EnergyGaugeGll FLRCPB v3.21 FORM 600A-2001 Code Compliance Checklist Residential Whole Building Performance Method A - Details ADDRESS: 6208 Silver Oaks BLVD., Zephyrhills, FL, 6A-21 INFILTRATION REDUCTION COMPLIANCE CHECKLIST PERMIT #: COMPONENTS SECTION REQUIREMENTS FOR EACH PRACTICE CHECK Exterior Windcws & Doors 606.1 ,ABC,1 ,1 Maximum:,3 cfmlsa,ft, window area' ,5 cfmlsa,ft, door area, Exterior & Adjacent Walls 606,1.ABC,1.2,1 Caulk, gasket, weatherstrip or seal between: wlndowsIdoors & frames, surrounding wall; foundation & wall sole or sill plate; Joints between exterior wall panels at comers; utility penetrations; between wall panels & toplbottom plates; between walls and floor, EXCEPTION: Frame walls where a continuous Infiltration blIrrier is installed that extends from and is sealed to the foundation to the too DIale. Floors 606,1,ABC,1,2,2 Penetrationsfopenings >118" sealed unless backed by truss or joint members, EXCEPTION: Frame floors where a continuous infiltration blIrrier Is installed that Is sealed to the oerimeter oenetrations and BeBms, Ceilings 606,1.ABC,1,2,3 Between walls & ceilings; penetrations of ceiling plane of top floor; around shafts, chases, soffits, chimneys, cabinets sealed to continuous air blIrrier; gaps in gyp board & top plate; attic access, EXCEPTION: Frame ceilings Where a continuous Infiltration blIrrier is installed that is sealed at the oerimeter at oenetrations and seams, Recessed Ughting Fixtures 606,1 ,ABC,1 ,2,4 Type IC rated with no penetrations, sealed; or Type IC or non-IC rated, installed Inside a sealed box with 112" clearance & 3" from insulation; or Type IC rated with < 2,0 cfm from conditioned soace tested, MuJti-storv Houses 606,1.ABC,1,2,5 Air blIrrier on oerimeter of fJoor cavitY between floors, Additional Infiltration reqts 606,1 ,ABC ,1 ,3 Exhaust fans vented to outdoors, dampers; combustion space heaters comply with NFPA, have combustion air, 6A-22 OTHER PRESCRIPTIVE MEASURES Imust be met or exceeded bv all residences.) COMPONENTS SECTION REQUIREMENTS CHECK Water Heaters 612,1 Comply with effICiency requirements in Table 6-12, Switch or clearly marked circuit breaker (e1ectrlcl or cutoff Caasl must be orovided, External or built-in heat traD reauired, Swimming Pools & Spas 612,1 Spas & heated pools must have covers (except solar heated), Non-commercial pools must have a pump timer, Gas spa & pool heaters must have a minimum thermal .. efflciencv of 78%, Shower heads 612,1 Water flow must be restricted to no more than 2,5 aallons oar minute at 80 PSIG, Air Distribution Systems 610.1 All ducts, fittings, mechanical equipment and plenum chambers shall be mechanically attached, sealed, insulated, and installed in accordance with the criteria of Section 610. Ducts in unconditioned attics: R-6 min, insulation, HVAC Controls 607.1 Seoarate readilY accessible manual or automatic thermostat for each sYStem, Insulation 604,1 , 602,1 Celfings-Min, R-19, Common walls-Frame R-11 or CBS R-3 both sides, Common ceiling & floors R-11, EnergyGauge TII DCA Form 600A-2001 EnergyGaugdfFlaRES'2001 FLRCPB \13,21 I April 26 2002 Linda & Brian Guerette, 6208 Silver Oaks Dr. ZephyrhilJs, FI, 33541 Dear Mr &Mrs. Guerette . We received the Silver Oaks Design Review Application dated April 25 2002 on April 25 2002, We have reviewed your application in reference to a room addition to your lanai and also having a swimming pool installed. After careful review of the application, the Design Review Committee has approved the application. The Design Review Committee will retain the Original application and drawings for it's records. If you have any further questions regarding this matter, please feel free to contact me at 813-782-1383, We appreciate your cooperation in submitting the application to the Design review Committee. Thank Ytml r?~ ~~ Charlie Mackin, Chainnan, Design Review Committee CC/Design Review Committee Application 2002-091 Silver Oaks Board of Directors