Loading...
HomeMy WebLinkAbout03-1831 5 ;j. r Gel~':TR~ ~G :::::::~' ~:t7 fl!!J~)~~~~T: BUILDING PERMIT' CITY OF ZEPHYRHILLS Permit N! (813) 780-0020 1831 /' Date 02 - /I-D~ M~AL Sewer Conn Water Conn: Water Meter: T.I.F.'s: Parcel I. D, , Zoning: DescriDtion of Work FINAL J. ,;/~ Complete Plans, Specifications and Fee Must Accompany Application. C.O. All work shall be performed in accordance with City Codes and Ordinances. DATE Inspector Valuation or Contract Price () City license Registration # Company Address ----~'7? '2.../0'0 State Certif;ed Ucense# ~hone# Ifl y . - Q<",Jo,{f.~ ~ { . ~I./Yl('." ELECTRICAL c:2 <;: .s- 6- PLU NG HANICAL /. --..--- Breakers Ducts Insl. Compressor Final SLB Tub Set Water Sewer Final Driveway Tp. Servo Rough In Meter Can Const. Pole Pool Pre-Meto/ Final ,f c2 -It.( -()3 !2U1 :5ee Ahove N~ ~ Ftr. Pre SLB Lintel FRM. Insul. CL WL REINSPECTION FEES: When extra inspection trips are necessary due to anyone of the following reasons, a charge of twenty-five and 00/100 Dollars ($25.00) shall be made for each trip for each trade: a. Wrong Address b. Condemned work resulting from faulty construction. c. Repairs or corrections not made when inspection called. d. Work not ready for inspection when called. e. Permit not posted on job site. f. Plans not at job site. g. Work not accessible. The payment of inspection fees shall be made before any further permits will be issued to the person owning same. CITY OF ZEPHYRHILLS PERMIT APPLICATIO~ BUILDING DIllPARTMENT 5335 8~ STRE~T ZmPHYRHILLS, FL 33540. PhoneI813-780-Q020 FaxIB13-7BO-0021 IJA'rE RIlIOl!lIVEn -d-::-IL-i)3 PI,ANS R!llVIBlW Jl'llIB1 C"_n_~_' CMNElR '8 11Af11El 711r C~l/L. RB-Iv~~ PHONE (~ON'l'lV~'~'"_.__ ___._ ---~--_._._--...._.~_.-._---_._---_._--_...._~._---_.-~~---'-'--' -..-------.-- ,TOB SI'l'E ADDRESS .22IL___.6A-./L_Pb:~_______._____.__ m_.__. n_____...____._____._ !J81GAL DESCRIPTION: LOT(8) BUX!K SUBIJIVISJON PARC1l!ll, In It (OB'rAIN P'ROM PROPElR'rV '1'1\J{ N01'WIll) w____..__..___._..._~..__~____..______...._,.._ ----.-.-......_._______.._--0 HrJRK I?ROPSE[J I []NElN l'ONs'rRtlC'TION [] 1\f)DI'rIdN o ALTERATION ~P1\IR LI INSTAl,!, [Is IG/T [J MOVE [J DEltlJOl,ISII PR(WOSEJIJ UBE: I [JSGII, F1\fvlILY DWELrJIW~ ~tll~1ElRl'JAI' []r1UUl'r. FAfvlII.Y 0# OF UNITS [J SN H1MINQ POUL [] MOBII,El lIotlJlll [] INDUSTRIAlJ U OTHI!lR o R~:8T1\URANT & HElAl,TH DEPARTt~ElN'r APPROVAL 11E8CRIP'l'ION OF 110RK __~tpt,.~F -----9..~.:::.~~r.-l ; m4-,ec_-;.~"*"__..!!!~/,c.~._____~_ BtJILDIWl SIZE ---------.----. -.----.-- SQUARE FOOTAGE HE J GUT ____.___.._.______.__ RBl8IDElNTIALI (~OMMElR(!IAlJ : A'I"r1\CH (2) PI,o,!, PIJA118 & (2) SElTS OF BUII,DIN<J PLANS & (1) SEl'r ElNEJRr~'i FORMS. A'I"liACH (J) SETS OF BUILJJtNQ PLANS & (1) SET ENElFWY FORMS. PROPERTY SURVEY REQUIRED FOR 1\LL NEW CONSTRUCTION, }?EIU1I'AS REQUBlSTBlD [J BlJJI.lJINl~ [~I1JC'I'RWAI. $__-?.ftJP VALUATION OF T01'AL CONs'rRuc'rION /' ---.------- AtIJP SEJRVICEI 0 FU)RIDA POWER ff W. R, E. n. [] PI.UtIJB ING o 1.1EiCIl1\N!C!AI, , $--,..----'-------- VALUATION OF tlJECIlANCIAI, H1STAlJl,ATION [] (JAS [1 ROOFING [OJ SI?BlC!IAUry [) OTHER 'l'Y'PEl OF CON8'1'RtJc'rIDN I [J BLOCK [J FRAME [] STElEI, [] OTHElR FIN ISHEllJ FLOOR ElIJEVliTIONS IS PRO,TElC'f' IN FLOOD ZONEI AREA 0 YBlS o NU BunnmR cot~P ANY_.__....______..______._._....___... __."__'" ..__....____._. '___ STATE CElRT OR RElGIST # _________.___________.________ CITY PROCESS INQ L... _____...__..__...______.__.. ___..._ __ ._.. __ 81GNATlJRE ****************************************************************** /'7~ / ~ COflPAHY~L,~LC.~-,--,,_.__, ::'::::~::,A_"U~_~,__ . ..___ .'_____. ~';~~"~~~~B~~H~O~T S;;?s;: __,__ __.. ... --_.. _.._._~---- _..... _. - ---.-- . ----- *h**h***h********************************************************* PI,UMBBlR COMPANY --------""7""---------_..__.__."_________._ STATE CElR'l' OR REGIST # ________._______... CITY PROCESSING # 8IGNA'l'lJREJ ._.._._.._._----~-------_..- ..-._..._--~.__.__.- MEC!HA1UCAf. ************************h****************************h************ ......_----------~---~.__....,------ (!olvJPANY __________.___._..___________...._. __..__.__ STATE CEJRT OR REGIS'r # CITY PROCESSING # -~----,.__..~------..-.---_..____.~__h _ STGNA'I'UREl ---_.__.~--~--------_._-_.__. - ---.----. ***************************************************************** OTlHlJR (~01IIPANY S '1' 1\ l' El CBlR T OR -RiCiJ8i11r-------.---------.--. -"---.- CI'rY PROCESSING # ---------.....--.------ S ImlA'I'UREJ ***************************************************************** -~'----"--~'-'-_._,------,-,-"---,---,--",~",,,,-, CONDI'l'IONS OF PERMI'r AFlnDAVIT A. NOTIC! OF D~ED RESTRICTIONS ~he uq.dersigned understanda th~t thil> perrnit may be subject to "deed restrictions" widell m~y be more restrictive than City regulations. Tile undersigned assumes responsibility for compliance with any applicable deed restrictions. B. UNLICENSEDc'ON'l'RAC'l'ORS AND CON'l'HACTOR RESPONSIBII,I'l'IES If the owner has hired a contractor or contractors to undertake work, they Il\ay be required to be licensed in accordance ~~ith state and local regulations. If the contractor is not lioensed as required by law, both the owner and oontractor may be cited for a misdemeallor violation under state laH. If the owner or intended contractor are uncertain as to what li censing regui rement.s may apply for the intended work, they are advlsed to oontact the City of Zephyrhills Building Department, 813-788-6611. FurtheruloJ::e, if the owner has hired a contractor or contractors, he is advised to have the contracto~(s) sign portions of the "Contractor Sections" of this application for which they HlJ 1. be .Lesponsible. If you, as the owner signs CIS the contractor, YQl,I are i.ndicating that YOII, rather than the contractor, are responsible for the work. If the contractor wishes you to sign a.:l contractor that may be an indication that he 113 not properly licensed and is llOl entitled to permitting priv1.leges in the City of Zephyrh1.lls. c. 'l'RANSPOR'l'A'rION I MPAC'l' FEES AND U'l'ILI'l'Y CONNECTION FEES D. CONS'rR\JCTlJION J,IEN LAW (CHAP'l'ER 713, FLORIDA S'l'ATUTES, AS AMENDED) I certify that I, the applicant, have been provided with a copy of "Flor1.da's Construction lien Law - Homeowner's Protection Guide" prepared by the Florida Department of Agri.oulture and Consumer Affairs. If the applicant is someone other that the "owner", I cerify that I have obta1.ned a copy of the above described document and promise in good faith to deliver 1. t to the "owner" pri.or to corrunencement. E. CON'l'RAC'I'OR' S/OWNER' S AFFIDAVI'l' I certify that all the information in this applicatlon is accurate and tllat all work will be done in compliance with all applleable laws regulatlng construction, zonlng, and land devi?lopment. Applioation is hereby made to obtain a permit to do work and installation as indioated. I certify that no Hark or installati.on has commenced prior to issuance of a permi t and that all work will be performed to meet standards of all laws regulatlng construction, City codes, zoning regulations, and land development regulations in the jllrisdiction. I also certify that I understand that the regulations of other governmental agencies !nay apply to tile intended work, and that it is my responsibility to identify what actiona I mllst take to be in compliance. Such agencies include but are not limited to: *Department of Environmental Regulation-Cypress Bayheads, Wetland Areas and Environmentally Sensitive Lands, Water/Wastewater Treatment *Soutllwest Florida Water Management District-Wells, Cypress Bayheads,-Wetland Areas, Altering Watercourses ~Army Corps of Engineers-SeawallS, Docks, Navigable WaterHays *Department of Health 6< Rehabilitative Services, Environmental Health Unit-Wells, Wastewater Treatment, Septic Tanks *U,5. Environmental Protection Agency-Asbestos abatement I also certify that, if fill material is to be used in Flood Zone ~A" or "A, etc.", it is understood that a drainage plan addressing a "compensating volume" 'will be submitted which is prepared by a professional engineer registered in tile state of Florida pr1.or to permit issuance. A permit isslled shall be construed to be a license to proceed with the work and not as authority to violate, cancel, alter, or set aside any provisions of the technical codes, nor shall issuance of a permit prevent the Building Official from thereafter requ1.ring a correotion of errors in plans, construction, or violations of any code. Every permit issued shall beoome invalid unless the work authorized by such permit is oOllunenoed within six months of issuance, or if work authorized by the penui.t ls sllspended or abandoqed tor a period of ai.x months after the time the work is commenced. One 90 day extension of time may be allowed for the permit with fee charge of $15.00. The extensi.on shall be requested in writing to the Buildi.ng Official, An approved inspection must be logged during each si.x month peri.od, or the pr'oj ect Hill be considered abandoned. WARNING TO OWNER: YOUR FAUURE 'fO RECORD A No'rICE OF COMMENCEMENT MAY RESUL'l' IN YOUR PAYING 'l'WICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO oB'rAIN FINANqINq, ~(4NfiUL'r WI'l'H YOUR LENDER OR AN A'l''I'ORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. JOBS UNDER $2,500 IN VALUE DO NO'l' NEED TO RECORD AND POS'l' A "NOTICE OF COMMENCEMEN'llll. SlGNA'l'lJRE: OWNER OR AGENT SIGNATURE: CONTRACTOR S'J'A'l'E OF FLORIDA COUNTY OE' 'l'he foregoing instrument was Before me this __ day of by acknowledged , 1!L- STA'rE OF nORIDA COUWry OF The foregoing instrument w~s aokno\<11 edged Before me this -------J.iay of----, 19 by (name of person aoknowledged) DIho is personally kno\'m to me, or (name of person acknOWledged) Dwho is personally known to me, or Owho has produced (type and what] did [] did not of i.denti.ficationl take an oath. o who has produced__. (type of identification) and Vlho Ddid OUd not t,ake an oath Signature of person taki.ng acknowledgement Signature of person taking acknowledgment Name typed, printed or stamped Name typed, printed or stamped ~ ,-- .- .. ... ..... E,..AlllCU..c. ;;: . 5446 Frontier DrivE 'Zephyrhills, FL 3354< (813) 779-210C 02/16/03 Bob Youmans; These are the actual load calculations for The Clock Restaurant that you requested. These readings were taken on Saturday, Feb, 15th 2003 at 12:30 PM, According to the manager, this is their busiest time of the week. The readings for this building are low because the grills, HWH, dish dryer and ovens are all natural gas operated. I hope this information is what you were expecting. For any further questions, please call me at 813-779-2100 Thank-you Chris Horton President ~ rltC!oe K Rt:~-I-II (/,eI9~ pl'r~/;1 f -+- r (OOA ,""ft Cc~tllt~ MOl - PtrtJCL C + :: {bD II P1+";~(. 13 + -;: t1..5" 19 + <Ht-I [ (OO(YICII l/' J J/UJ~{I€ 2 ~..E' f Z. ",rf<~ '3 tf 4,) (J4-AJtL 0 + = 10014 {>h~a t +~(S)A (JA!J[( II +- -= 225" F/ P /'tIfI rt t1 + ~ 12SA ( K.+ch (111 h 09+) -,,;er/- C)5.eD - J PANEL DIRECTORY PANEL: A 3 phase wI 200a main CKT# AMPS Load I Amps CKT# AMPS Load I Amps 1 * 0 2 xxx 3 30 3p 0 4 30 2p spare 5 * 0 6 * 7 * 0 8 * 9 30 3p 0 10 60 3p spare 11 * 0 12 * 13 * 14 * 0 15 60 3p spare 16 60 3p 0 17 * 18 * 0 19 * 20 * 21 60 3p spare 22 60 3p spare 23 * 24 * 25 26 * 0 27 28 20 3p 0 29 30 * 0 31 32 33 34 35 36 37 38 39 40 , I~ 4/0 to main panel under 225 amp breaker A ph. - 0 amps B ph. - 0 amps C ph - 0 amps PANEL DIRECTORY PANEL: B 3ph w/ MLO CKT# AMPS Load / Amps CKT# AMPS Load / Amps 1 20 1.2 2 20 .2 3 20 spare 4 20 .1 5 20 10.7 6 20 2.1 7 xxx 8 xxx 9 20 .2 10 20/20 .1/0 11 20 .7 12 20 .2 13 20 6.7 14 20 6.6 15 20 9.6 16 20 .9 17 xxx 18 20 .2 19 xxx 20 20 6.0 21 20 0 22 20 0 23 20 .1 24 xxx 25 xxx 26 20 .1 27 20 4.3 28 * 8.8 29 * 1.9 30 60 8.2 31 20 3p 2.7 32 * 5.2 33 * 2.5 34 xxx 35 36 20 2p 0 37 38 * 0 39 40 41 42 1/0 eu to main panel under 125 amp breaker A ph - 24.3 amps B ph - 22.5 amps C ph - 29.4 amps PANEL DIRECTORY PANEL: C 3ph 150a main CKT# AMPS Load / Amps CKT# AMPS Load / Amps 1 20 3.2 2 * 2.6 3 15 1.9 4 20 3p 2.6 5 20 1.1 6 * 2.7 7 30 2.7 8 20 5.0 9 20 4.2 10 20 5.1 11 20 1.0 12 20 .1 13 20 .1 14 20 1.9 15 20 1.1 16 20 2.9 17 20 1.1 18 19 30 9.4 20 21 22 23 24 25 26 27 28 29 30 ., ~ ) L. I ., 1/0 eu to main panel under 100 amp breaker A ph - 8.1 amps B ph - 12.5 amps C ph - 23.8 amps PANEL DIRECTORY PANEL: D 3ph w/ MLO CKT# AMPS Load / Amps CKT# AMPS Load / Amps 1 20 .5 2 xxx 3 30 2p .1 4 20 3.9 5 * .1 6 20 2p 2.9 7 20 .3 8 * 2.7 9 20 2p 7.4 10 xxx 11 * 0 12 20 6.2 13 30 2p .1 14 20 .8 15 * .1 16 20 2.4 17 20 2p 3.4 18 20 2p 9.6 19 * 4.0 20 * 8.7 21 20 0 22 20 .1 23 20 8.4 24 30 2p .2 25 20 5.8 26 * 5.2 27 20 0 28 xxx 29 * 0 30 xxx ': :) ~ L !/O eu to main panel under 100 amp breaker A ph - 25.2 amps B ph - 13.7 amps C ph - 38.4 amps PANEL DIRECTORY PANEL: E 3ph wI MLO CKT# AMPS Load I Amps CKT# AMPS Load I Amps 1 xxx 2 xxx 3 xxx 4 xxx 5 20 .3 6 xxx 7 20 .1 8 * 0 9 20 .6 10 50 3p 0 AlC # 3 11 20 2.4 12 * 0 (not working - 13 * 15.0 14 * 15.0 being replaced) 15 50 3p 19.4 AlC#2 16 50 3p 19.4 17 * 19.8 18 * 19.7 1 :;J 2 2 2 2 2 "2 2 ~ 2 -;, 3 3 ~ 3 D 3 8 ,., D ..J .::I ~ .~ 1U'S I OA,.}C L ~ r jf, {jl/t __'- 1/0 cu to main panel under 150 amp breaker A ph - 30.4 amps B ph - 39.4 amps C ph - 45.0 amps